SOLENOID VALVES pilot operated, spool type single/dual solenoid (mono/bistable function) stainless steel body, NAMUR, 1/4-1/2
|
|
- Joan Davis
- 5 years ago
- Views:
Transcription
1 SOLNOI VLVS pilot operated, spool type single/dual solenoid (mono/bistable function) stainless steel body, NMUR, / - / / N / 0 /-/ Series FTURS Series monostable spool valves / have TÜV certifi ed I 60 Functional Safety data and can be used up to SIL /K 7 The solenoid operated spool valves have threaded port connections and "NMUR" interface The same spool valve can be adapted for / N or / functions for controlling double-acting and single-acting actuators ll the exhaust ports of this spool valve are connectable, providing better environmental protection, particularly recommended for sensitive areas such as clean rooms, and applications in the pharmaceutical and food processing sectors The valve offers environmental protection against the ingress of liquids, dusts or any other foreign matter (environmentally-protected construction) an be externally piloted (external air pilot supply) to convert valve to zero minimum operation by fl ipping a gasket The solenoid valves satisfy all relevant irectives GNRL ifferential pressure - 0 bar [ bar =00 kpa] Flow (Qv at 6 bar) / = 700 l/min (NR) / = 000 l/min fluids ( ) temperature range (TS) seal materials ( ) air, inert gas, fi ltered : - 0 to + 0 : - 0 to + 60 VMQ (silicone) + PUR (polyurethane) MTRILS IN ONTT WITH FLUI ( ) nsure that the compatibility of the fluids in contact with the materials is verified ody, end covers Stainless steel, ISI 6L Interface plates Glass-fi lled P Spool valve internal parts Stainless steel, POM ore tube Stainless steel ore and plugnut Stainless steel ore spring Stainless steel Seals & discs NR Top disc FPM isc holder POM artridge (Low ) Welded, packless ISI 0 Seat Stainless steel Seat insert POM Shading coil opper Rider ring (Low ) PTF SPIFITIONS pipe orifice flow coefficient kv operating pressure differential (bar) prefix optional solenoids max. (PS) level NM TX/NL (gas/dust) min. () RP-MP basic catalogue number IP6 air ( ) 7 & x d x em x m x i x n ( ) (mm) (m /h) (l/min) ~ = ~/= F NF NK M PV IS ZN S Solenoid air pilot operated - spring return (monostable) / 6 0, / 0 0 P () / 6 0, / 0 0 P G0 () / 6 0, / 0 0 LP () / 6 0, / 0 0 LP G0 () /,, 0 / 0 0 P /,, 0 / 0 0 P G0 /,, 0 / 0 0 LP /,, 0 / 0 0 LP G0 Solenoid air pilot operated and return (bistable) / 6 0, / 0 0 P / 6 0, / 0 0 P G0 / 6 0, / 0 0 LP / 6 0, / 0 0 LP G0 /,, 0 / 0 0 P /,, 0 / 0 0 P G0 /,, 0 / 0 0 LP /,, 0 / 0 0 LP G0 Select for NSI.0. or select G for ISO G (/) vailable feature vailable feature in only () ertified I 60 Functional Safety data, use suffi x "SL" () Zero minimum is only achieved if external pressure is applied UP ll leafl ets are available on: LP Not vailable 0,W -,W Ultra Low Low P Not vailable 0,W -,W Reduced and Medium asic POWR LVLS - cold electrical holding values (watt) PI-6--G 00/R0
2 SRIS - PRFIX TL prefi x level description 6 7 LP RP MP P S U ustproof TX (N 0--) * F xplosionproof - NM,, 6, 7, - - V xplosionproof - NM,, 6, 7, - 6 SS - - M ncapsulated TX + Ix (N/I 6007 / 6)* - - T Threaded conduit/hole (M0 x.) - - I S S Intrinsically safe with S coil TX (N 000) * N F Flameproof - lum. TX + Ix (N/I 6007 / 6)* - - N K Flameproof - lum. TX (N 6007 / 6) * P V ncapsulated TX + Ix (N/I 6007 / 6)* - - S Solenoid with spade plug connector (N 6070) - - W P Waterproof IP67 - Metal enclosure (N 6070) - - W S Waterproof IP67-6 SS enclosure (N 6070) - - W S M 6 SS "M" encl. TX + Ix (N/I 6007/6)* - - W P U ustproof TX (N 0--) - Metal enclosure * W S U ustproof TX (N 0--) - 6 SS enclosure * W P I S I.S. with Metal IP67 enclosure TX (N 000) * W P Z N N.S. metal enclosure TX (N 00)* - - W S I S I.S. with Metal IP67-6 SS enclosure TX (N 000) * W S N F Flameproof - St. steel 6 TX + Ix (N/I 6007 / 6)* - - W S Z N N.S. 6 SS enclosure TX (N 00)* - - Z N ncapsulated Non Sparking TX (N 00) * - - T Threaded conduit (/" ) - - H T lass H - High temperature, +0 ambient temp X Other special constructions - - SUFFIX TL suffi x level description 6 7 LP RP MP P M O Push type or screw type manual operator / - - S L ertifi ed I 60 Functional Safety data (Series ) () / - - PROUT SLTION GUI STP Select the fl uid temperature range and seal material from the general table on page 7. Select basic catalogue number, including pipe thread identifi cation letter. Refer to the specifi cations table above. xample: G0 STP Select prefi x (combination). Select the appropriate operator from the specifi cations table on page and the prefi x table on page. Select for this operator in the electrical characteristics table on page : the level (LP, P), the type of electrical enclosure protection and the desired temperature class. Warning: The ambient temperature range of your application may not exceed the temperature range of your operator. xample: M STP Select suffi x (combination) if required. xample: MO STP Select voltage. Refer to standard voltages on page. xample: 0V / 0Hz STP Final catalogue / ordering number. xample: M G0MO 0 V / 0 Hz OPTIONS & SSORIS series stainless steel pipe exhaust protector G - / 600 () 600 () / 600 () 600 () / vailable feature vailable feature in only - Not available * TX solenoids are also approved according to N/I 6 (ust) and N 6- (non electrical valves) () Provided with "SL" suffix () Not to use with MO suffi x ORRING XMPLS: S G 0 0V / 0 Hz S G 0 0V / 0 Hz S G 0 SL 0V / 0 Hz S G 0 MO 0V / 0 Hz SHT 0 MO 0V / 0 Hz ISS G 0 MO V / S 0 0V / 0 Hz WPIS G 0 V / M 0 MO 0V / 0 Hz F G G 0 MO 0V / 60 Hz prefi x () pipe thread voltage basic number () suffi x () Prefi xes F and V should always be used with the letter G in the basic number. ll leafl ets are available on: /R0
3 SRIS - XPLNTION OF TMPRTUR RNGS OF SOLNOI VLVS Valve temperature range The valve temperature range is determined by the selected seal material, the temperature range for proper operation of the valve and sometimes by the fluid (e.g. steam) Operator ambient temperature range The operator ambient temperature range is determined by the selected level (LP, RP, MP or P) and the TX safety code Total temperature range The temperature range of the complete solenoid valve is determined by the limitations of both temperature ranges above LTRIL HRTRISTIS oil insulation class F lectrical safety I Standard voltages (=) V - V (~) V - V - V - 0V () /0Hz; other voltages and 60Hz are available on request ratings operator electrical ambient replacement coil prefix inrush holding hot/ temperature enclosure cold safety code option ~ ~ = range (TS) protection ~ = (V) (V) (W) (W) ( ) (N 60) 0 V / 0 Hz V type () asic (P) S 0, /, -0 to +7 N 6070 moulded IP SU 0, /, -0 to +7 II IP6 T 00 (~)/ (=) moulded IP6 - () - () 0 WP/WS 0, /, -0 to +7 N 6070 steel/ss IP WPU/WSU 0, /, -0 to +7 II IP67 T 00 steel/ss IP67 - () - () 0 (WS)NF 0, - [-60] () -0 to +/0/60 II G/ x d II T6/T/T/x t alu./ss IP (WS)NF /, [-60] () -0 to +0/60/7 II G/ x d II T6/T/T/x t alu./ss IP NK 0, /, -0 to +0/60 II G/ x d II+H T/x t aluminium IP M/WSM 0, /, -0 to +0 II G/ x emb II T/x t steel/ss IP PV 0, /, -0 to +6 II G/ x mb II T(~)/T(=)/x m moulded IP6 - () - () 0 F/V 0, /, -0 to +/0 NM type 7 and mould.nm X ZN 0, /, -0 to +0 II G/ x n II T moulded IP6 - () - () 0 WP(WS)ZN 0, /, -0 to +0/60 II G/ x n II T(~)/T(=) steel/ss IP67 - () - () 0 Low (LP) S,,,,7/,7-0 to +60 N 6070 moulded IP WP/WS,,,,7/,7-0 to +60 N 6070 steel/ss IP (WS)NF - -, - /, [-60] () -0 to +7/0 II G/ x d II T6-T/x t alu./ss IP67 - () - () 0 M/WSM,,,,7/,7-0 to + II G/ x emb II T/x t steel/ss IP67 - () - () 0 PV - - -,7/,7-0 to +6 II G/ x mb II T6 / x m moulded IP6 - - () 0 F/V - - -,7/,7-0 to +60 NM type 7 and mould.nm X - - () ISS () ,/0-0 to +60 II G/ x ia II T6(G/=) moulded IP WPIS () ,/0-0 to +60 II G/ x ia II T6(G/=) acier IP WSIS () ,/0, -0 to +60 II G/ x ia II T6(G/=) St steel IP ZN - - -,7/,7-0 to +0 II G/ x n II T moulded IP6 - - () 07 WP(WS)ZN,,,,7/,7-0 to +60 II G/ x n II T6 steel/ss IP67 - () - () 0 prefix option safety parameters U I = () I I P I L I I (V) (m) (W) (µf) (mf) Low (LP) ISS 00, 0 0 WPIS 00, 0 0 LTRIL ONNTIONS prefix connection S, SU, ZN WP, WS, M, WSM, WPU, WSU, WPZN, WSZN, WPIS, WSIS NF, WSNF NK PV F/V ITIONL OPTIONS () The certified minimum temperature of this operator () Refer to the dimensional drawings on pages to 6. () Intrinsically safe pilots: heck the electrical characteristics in the corresponding catalogue pages (ISS/WPIS operators). () Multiple coil kits available under TX, contact us () Low Power, 0 V does not exist. Maximum voltage in is V. - Not available Spade plug connector with cable gland N70-0 (ISO 00) for cables with an outer diameter from 6 to 0 mm M0 cable gland for cables with an outer diameter from 7 to mm. With an internal and external facility for an earthing or bonding conductor /" threaded cable entry. nclosures are supplied without cable gland /" threaded cable entry. nclosures are supplied without cable gland Moulded-in cable, standard length m /" conduits, standard length cm Valves confi gured for external pilot air supply, TPL 07 Other pipe threads are available on request x mb (prefi x "PV") execution can be supplied in various cable lengths ompliance with "UL", "S" and other local approvals available on request /" (prefi x "T") and M0 x. (prefi x "T") conduits (aluminium or 6 SS) available for steel solenoid housing INSTLLTION Installation/maintenance instructions are included with each valve The solenoid valves can be mounted in any position without affecting operation I 60 Functional Safety (Suffi x SL), allowable temperature range: -0 to +60. Probability of failure on demand, contact us Spool valve supplied with two interface plates with NMUR mating surfaces. epending on function (N / or /), position one of the two plates on the spool valve body before installing on actuator It is necessary to connect pipes or fi ttings to the exhaust ports to protect the internal parts of the spool valve and its pneumatic operator if used outside or in harsh environments (dusts, liquids etc.) owel pin (if necessary), bolts and gaskets are standard supplied Threaded pipe connection identifi er is: = (NSI.0.); G = G (ISO /) Prefi x "(WS)NF" enclosure is provided with a /" threaded entry hole [optionally, M0 x, (prefix "T")] and is supplied without cable gland Prefi x "NK" enclosure is provided with a /" threaded entry hole [optionally, /" (prefi x "T") or M0 x, (prefi x "T")] and is supplied without cable gland Valves with suffi x "SL" are provided with specifi c exhaust protectors ll leafl ets are available on: /R0
4 SRIS - IMNSIONS (mm), WIGHT (kg) Monostable Series istable Serie Mono/bistable 7,, / x /,6 0 / x /,6 /,6, x / 7,, Interface plates mounting holes. mm dia.; Spotfacing: mm dia., depth mm; screws (Hc M x ), engaged length: 7 One mm dia. hole for dowel pin - in position : / N function plate - in position : / function plate O-ring seals (supplied) mounting holes 6, mm dia.; Spotfacing: mm dia., depth 6 mm; screws (Hc M6 x 0), engaged length: 7 TYP 0: Prefixes S: IP6, ZN: II G/, IP6, x n II, SU: II, IP6, T00 to 00 asic poxy moulded I / ISO 00 0 / 0 / 0 / 0 TYP 0: Prefixes NF/WSNF: II G/, IP67, x d II asic luminium, epoxy coated (NF) ISI 6 SS (WSNF) N/I and N/I 6-0 / 0 / 0 / 0 6 / 0 / 0 6 TYP 0: Prefix NK: II G, IP6, x d II + H asic luminium, epoxy coated N and N 6-0 / 0 / 0 / 0 TYP 0: Prefixes WP/WS: IP67, M/WSM: II G/, IP67, x emb II, WPU/WSU: II, IP67, T to 00, WPZN/WSZN: II G/, IP67, x n II asic Steel, epoxy coated (M, WP, WPU, WPZN) ISI 6 SS (WS, WSU, WSM, and WSZN) I / N / and N 6-0 / 0 / 0 / 0 / / /, 6, 00 ll leafl ets are available on: /R0 6--
5 SRIS - IMNSIONS (mm), WIGHT (kg) TYP 0: Prefix PV: II G/, IP67, x mb II, x m asic poxy encapsulated N/I and N/I 6-0 / 0 / 0 / 0 TYP 06: Prefixes F/V: IS-6 NSI / NM type 7 and asic poxy encapsulated IS-6 NSI / NM Type 7 and NOT: applicable to solenoid only G0 / G0 / G0 / G0 / / "T" (M0x,) "T" (/ ) 6 TYP 07: Prefixes S: IP6, ZN: II G/, IP6, x n II Low poxy moulded I / ISO 00 0 / 0 / 0 / 0 TYP 0: Prefixes NF/WSNF: II G/, IP67, x d II Low luminium, epoxy coated (NF) ISI 6 SS (WSNF) N/I and N/I 6-0 / 0 / 0 / 0 / 0 / 0 6 TYP 0: Prefixes WP/WS: IP67, M/WSM: II G/, IP67, x emb II, WPU/WSU: II, IP67, T to 00, WPZN/WSZN: II G/, IP67, x n II, /WSIS: = II G/ x ia II - = II G/ x ia II Low Steel, epoxy coated (M, WP, WPU, WPZN, WPIS) ISI 6 SS (WS, WSU, WSM, WSIS and WSZN) I / N / and N 6-0 / 0 / 0 / 0 TYP 0: Prefix PV: II G/, IP67, x mb II, x m Low poxy encapsulated N/I and N/I 6-0 / 0 / 0 / 0 / / 0 6 ll leafl ets are available on: /R0
6 SRIS - IMNSIONS (mm), WIGHT (kg) TYP : Prefixes F/V: IS-6 NSI / NM type 7 and Low poxy encapsulated IS-6 NSI / NM Type 7 and NOT: applicable to solenoid only G0 / G0 / G0 / G0 TYP : : II G/ x ia II, IP6 - : II G/ x ia II, IP6 Low Polypropylene moulded I / ISO 00 N 000 and N / 0 / 0 / 0 / "T" (M0x,) "T" (/ ) / 6 67 Serie Serie weight () type prefixe option level monostable bistable 0 S / SU / ZN basic 7 0, 7 7 6, 0,,6,0, 0 NF basic ,6,,0 6,6 0 WSNF basic ,, 7,00, 0 NK basic ,0,,0, 0 WP/WPU/WS/WSU/M/WSM basic ,7,,0,6 0 PV basic 7, 6 0 6,,6,7,0, 06 F / V basic 7 0,, ,,6,7,0, 07 S / ZN low 7 07, 6 6, 0,,6,0, 0 NF low ,6,,0 6,6 0 WSNF low ,, 7,00, 0 WP / WS / M / WSM / WPIS / WSIS low ,7,,6,6 0 PV low 7 06, 6 6,,6,7,0, F / V low 7 06, 7 6,,6,7,0, ISS low 7 0, 0 6, 0,6,7,0, () Incl. coil(s) and connector(s) x d certifi ed cable gland (on request) Three-core cable, length m able gland for unarmoured cable with 7 to mm dia. sheath 6 onnector rotatable by 0 increments (cable Ø 6-0 mm) Manual operator location, suffi x MO xternal pilot air supply, / pipe onnectable pilot exhaust port Non-connectable pilot exhaust port SSORIS ø ø / / 0 / pilot exhaust protector part number pilot top exhaust low (SO solenoid interface) Ø Ø - / / / - 0 exhaust protector (stainless steel) ll leafl ets are available on: /R0
7 SPOOL VLVS pilot or air operated, spool type single/dual solenoid (mono/bistable function) stainless steel body, NMUR, / - / / N / 0 /-/ Series FTURS Series monostable spool valves / have TÜV certifi ed I 60 Functional Safety data and can be used up to SIL /K 7 Series versions according to TX //, for zones 0, and and series air-operated versions for zones and The solenoid operated spool valves have threaded port connections and "NMUR" interface The same spool valve can be adapted for / N or / functions for controlling double-acting and single-acting actuators ll the exhaust ports of this spool valve are connectable, providing better environmental protection, particularly recommended for sensitive areas such as clean rooms, and applications in the pharmaceutical and food processing sectors The valve offers environmental protection against the ingress of liquids, dusts or any other foreign matter (environmentally-protected construction) The solenoid valves satisfy all relevant irectives GNRL ifferential pressure - 0 bar [ bar =00 kpa] Flow (Qv at 6 bar) / = 700 l/min (NR) / = 000 l/min fluids ( ) temperature range (TS) seal materials ( ) air, inert gas, fi ltered : - 0 to + 0 : - 0 to + 60 VMQ (silicone) + PUR (polyurethane) MTRILS IN ONTT WITH FLUI ( ) nsure that the compatibility of the fluids in contact with the materials is verified ir operated NOMO solenoid (pilot) interface (Series -) (Series ) ody, end covers Stainless steel, ISI 6L Stainless steel, ISI 6L Interface plates Glass-fi lled P Glass-fi lled P Spool valve internal parts Stainless steel, POM Stainless steel, POM Seals NR NR Pilot internal parts - Size 0 (06.0.0N), refer to catalogue pages: 7 pilot (TNK) and pilot (ISS) IR OPRT SPIFITIONS pipe orifice flow coefficient kv operating pressure differential (bar) prefix optional basic catalogue number max. (PS) min. air ( ) ( ) (mm) (m /h) (l/min) ~ = Pilot air operated - spring return (monostable) / 6 0, () /,, Pilot air operated and return (bistable) / 6 0, /,, UP LP Not vailable,6w Ultra Low Low RP-MP P Not available 0,W -,W Reduced and Medium asic POWR LVLS - cold electrical holding values (watt) NOMO SOLNOI (PILOT) INTRF SPIFITIONS pipe orifice flow coefficient kv operating pressure differential (bar) min. level prefix optional solenoids max. (PS) TX/NL (gas/dust) air ( ) x d x i basic catalogue number ( ) (mm) (m /h) (l/min) ~ = ~/= TNK ISS Solenoid air pilot operated - spring return (monostable) / 6 0, P - 0 () / 6 0,6 0 - LP - 0 () Solenoid air pilot operated and return (bistable) / 6 0, P - 0 / 6 0,6 0 - LP - 0 Select for NSI.0. or select G for ISO G (/) vailable feature vailable feature in only. () ertified I 60 Functional Safety data, use suffi x "SL". ll leafl ets are available on: /R0
8 SRIS - PRFIX TL prefi x level description 6 7 UP LP RP P T N K Flameproof with pilot 7, TX (N 6007 / 6) * I S S Intrinsically safe, pilot, TX (N 000) * SUFFIX TL suffi x level description 6 7 UP LP RP P G Non-electrical, G c ()/ G c (), TX (N 6-) M S Screw type manual operator M O Push type or screw type manual operator S L ertifi ed I 60 Functional Safety data (Series ) () - - OPTIONS & SSORIS series stainless steel pipe exhaust protector G / 600 () 600 () / 600 () 600 () / vailable feature vailable feature in only - Not available * TX solenoids are also approved according to N/I 6 (ust) and N 6- (non electrical valves) () Not to use with MS or MO suffi x () Provided with "SL" suffix PROUT SLTION GUI STP Select the fl uid temperature range and seal material from the general table on page 7. Select basic catalogue number, including pipe thread identifi cation letter. Refer to the specifi cations tables on page 7. xample: G0 STP Select prefi x (combination). Select the appropriate operator from the tables on page 7. Select for this operator in the electrical characteristics table on page : the level (LP, P), the type of electrical enclosure protection and the desired temperature class. Warning: The ambient temperature range of your application may not exceed the temperature range of your operator. ir operated version, does not use prefi x. xample : TNK STP Select suffi x (combination) if required. Refer to the suffi x table, respect the indicated level. G suffi x available for air operated version only (do not use manual operator suffi x). xample : MS STP Select voltage. Refer to standard voltages on page. ample : 0V / 0Hz STP Final catalogue / ordering number. xample : TNK G0MS 0 V / 0 Hz ORRING XMPLS: TNK G 0 0V / 0 Hz TNK G 0 SL V / TNK G 0 MS V / 0 Hz TNK G 0 0V / 0 Hz TNK G 0 MS V / TNK 0 0V / 0 Hz ISS G 0 V / ISS G 0 SL V / ISS G 0 MO V / ISS G 0 V / ISS G 0 MO V / G 0 G 0 G G 0 GSL G 0 G 0 G 0 G prefi x pipe thread basic number voltage suffi x ll leafl ets are available on: /R0
9 SRIS - XPLNTION OF TMPRTUR RNGS OF SOLNOI VLVS Valve temperature range The valve temperature range is determined by the selected seal material, the temperature range for proper operation of the valve and sometimes by the fluid (e.g. steam) Operator ambient temperature The operator ambient temperature range is determined by the selected level (LP or P) and range the TX safety code Total temperature range The temperature range of the complete solenoid valve is determined by the limitations of both temperature ranges above LTRIL HRTRISTIS oil insulation class F lectrical safety I Standard voltages (=) TNK : V - V ; ISS : V (~) TNK : V - V - V - 0V/0Hz - other voltages and 60Hz are available on request ratings operator electrical ambient replacement coil prefix inrush holding hot/cold temperature enclosure safety code option ranges (TS) protection type ~ ~ = ~ = () (V) (V) (W) (W) ( ) (N 60) - - asic (P) TNK 0, /, -0 to +60 II G/ x d II+H T/x t moulded IP Low (LP) ISS ()() - - -,6-0 to +0 II G/ x ia II T6 moulded IP Not available () Refer to the dimensional drawings on page 0.. safety parameters prefix U option I = () I I P I L I I (V) (m) (W) (µf) (mf) Low (LP) ISS,6 0 0 LTRIL ONNTIONS prefix connection TNK /" threaded cable entry. nclosures are supplied without cable gland ISS Spade plug connector with cable gland N70-0 (ISO 00) for cables with an outer diameter from 6 to mm ITIONL OPTIONS Other pipe threads are available on request INSTLLTION Installation/maintenance instructions are included with each valve The spool valves can be mounted in any position without affecting operation I 60 Functional Safety (suffi x SL), allowable temperature range: -0 to +60. Probability of failure on demand, contact us Spool valve supplied with two interface plates with NMUR mating surfaces. epending on function (/ N or /), position one of the two plates on the spool valve body before installing on actuator owel pin (if necessary), bolts and gaskets are standard supplied It is necessary to connect pipes or fi ttings to the exhaust ports to protect the internal parts of the spool valve and its pneumatic operator if used outside or in harsh environments (dusts, liquids etc.) x d (prefi x "TNK") enclosure is provided with a /" threaded entry hole [optionally, /" (prefi x "T") or M0 x, (prefi x "T")] and is supplied without cable gland Threaded pipe connection identifi er is: = (NSI.0.); G = G (ISO /) Valves with suffi x "SL" are provided with a specifi c exhaust protector ll leafl ets are available on: /R0
10 SRIS - IMNSIONS (mm), WIGHT (kg) Type 0-0: NOMO (Series ) 0 (06.0.0) Type 0: ir operated Series Series 67,, Interface plates mounting holes. mm dia.; Spotfacing: mm dia., depth mm; screws (Hc M x ), engaged length: 7 mm 0 / 0 0MS / 0MS G/ / x / x /,6,6 TYP 0: Prefix TNK: II G, IP6, x d II + H asic 7 pilot, light alloy luminium, epoxy coated N and N 6- G/ One mm dia. hole for dowel pin - in position : / N function plate - in position : / function plate O-ring seals (supplied) 66,7,, x / x / 0,6,6 TYP 0: Prefix ISS: Series : II G x ia II, IP6 Series : II G x ia II, IP6 Low pilot Polyamide I / ISO 00 N 000 and N / 0 0MO / 0MO 0 6, 07,6, x / 7 7,, mounting holes 6, mm dia.; Spotfacing: mm dia., depth 6 mm; screws (Hc M6 x 0), engaged length: 7 mm, 0 / 0 ll leafl ets are available on: / 0 77, 6, 00 TYP 0: No prefix, IP6 [suffixes : G (II G c) ; SL (SIL) ; GSL (SIL, II G c) suffixe : G (II G c)] ir operated version 6, 7,,, 6 weight () type prefix option level monostable bistable 0 TNK basic, -, - 0 ISS low, -, ,,6,7, () Incl. connector(s), except FVT. SSORIS Ø 7 0 onnector rotatable by 0 increments (cable 6-0 mm) Manual operator location x d certifi ed cable gland (on request) onnectable pilot exhaust port Non-connectable pilot exhaust port Ø - / / / - 0 exhaust protector (stainless steel) PI G -- vailability, design and specifications are subject to change without notice. ll rights reserved. 00/R0
SOLENOID VALVES pilot operated, spool type single/dual solenoid (mono/bistable function) stainless steel body, NAMUR, 1/4-1/2
SOLNOI VLVS pilot operated, spool type single/dual solenoid (mono/bistable function) stainless steel body, NMUR, / - / / N / 0 / / Series - FTURS The monostable spool valves have TÜV-XI certifi ed I 60
More informationSPOOL VALVES pilot operated or air operated, spool type single/dual solenoid or air (mono/bistable function) brass body, NAMUR, 1/4
SPOOL VLVS pilot operated or air operated, spool type single/dual solenoid or air (mono/bistable function) brass body, NMUR, / 0 /-/ Series 0006G-007/R0 vailability, design and specifi cations are subject
More information深圳市永旭伟业贸易有限公司 SOLENOID VALVES pilot operated, spool type single/dual solenoid (mono/bistable function) brass body, NAMUR, 1/4.
SOLNOID VLVS pilot operated, spool type single/dual solenoid (mono/bistable function) brass body, NMUR, / / N / /-/ Series 0 FTURS The monostable spool valves, series, have TÜV certifi ed I 60 Functional
More information3/2 5/2 5/3 Series
SPOOL VLVS pilot operated or air operated, spool type single/dual solenoid or air (mono/bistable function) aluminium body, NMUR style, / to / 0 / / / Series -- FTURS The monostable spool valves, series,
More informationSPOOL VALVES pilot operated or air operated, spool type single/dual solenoid or air (mono/bistable function) aluminium body, NAMUR style, 1/4 to 1/2
SPOOL VLVS pilot operated or air operated, spool type single/dual solenoid or air (mono/bistable function) aluminium body, NMUR style, / to / 0 / / / Series -- FTURS The monostable spool valves have TÜV-XI
More informationSPOOL VALVES pilot operated or air operated, spool type single/dual solenoid or air (mono/bistable function) aluminium body, NAMUR style, 1/4 to 1/2
SPOOL VLVS pilot operated or air operated, spool type single/dual solenoid or air (mono/bistable function) aluminium body, NMUR style, / to / / NC / 0 /-/ Series - TURS SCO/JOUCOMTIC solenoid valves satisfy
More informationSRIS PRFIX TL power level description 6 7 LP RP MP P F xplosionproof - NM 7, - Zinc plated steel conduit m - - V xplosionproof - NM 7, - 6 SS conduit
SOLNOID VLVS pilot operated, spool type single/dual solenoid (mono/bistable function) brass body, NMUR, / FTURS The monostable spool valves have TÜV certified I 60 Functional Safety data and can be used
More informationPILOT OPRT SPIFITIONS / pipe orifice flow coefficient kv operating pressure differential (bar) max. (PS) level optional solenoids SRIS -- basic catalo
SPOOL VLVS pilot operated or air operated, spool type single/dual solenoid or air (mono/bistable function) aluminium body, NMUR style, / to / 0 / / / Series -- FTURS The monostable spool valves have TÜV-XI
More informationSPOOL VALVES pilot operated or air operated, spool type single/dual solenoid or air aluminium body, NAMUR style, 1/4 to 1/2
FTURS pipe size ( ) orifice size flow coefficient Kv (mm) (m /h) (l/min) SPOOL VLVS pilot operated or air operated, spool type single/dual solenoid or air aluminium body, NMUR style, / to / SCO/JOUCOMTIC
More information5/2-5/3 SPOOL VALVES MULTIFUNCTION air operated or solenoid air operated with subbase ISO 5599/1 sizes 1, 2 and 3
/ - / SPOOL VALVES MULTIFUNCTION air operated or solenoid air operated with subbase ISO 99/ sizes, and Series Fluids air or inert gas, filtered, lubricated or not Operating pressure Pilot pressure Ambient
More informationair and solenoid air operated 5/2-5/3 ISO 5599/01 - Size 2
Series 4/PH MULTIFUNCTION SPOOL VALV air and solenoid air /-/ ISO 99/0 - Size ports / positions SPCIFICATIONS FLUID : or neutral gas, filtered, lubricated or not PRSSUR : 0,90 to + bar (can be used with
More informationDirect-operated 2/2-way compact solenoid valves Type EV210A
Data sheet Direct-operated 2/2-way compact solenoid valves Type EV210A EV210A covers a wide range of small, directoperated 2/2-way solenoid valves for use in industrial machinery. The compact design together
More informationIts modular concept allows to build up a ball valve for any degree of automation and any kind of application
Type 2657...59 DN 10 up to 80 mm; Plastic; 2/2 way dvantages/benefits ntegrated pilot valves, position feed-back and limit switches available Customized system solutions with Burkert valves & sensors With
More informationSolenoid valves 2/2-way direct-operated type EV210A
MAKING MODERN LIVING POSSIBLE Data sheet Solenoid valves 2/2-way direct-operated type EV210A EV210A covers a wide range of small, direct-operated 2/2-way solenoid valves for use in industrial machinery.
More informationDirect-operated 2/2-way solenoid valves Type EV210B
Data sheet Direct-operated 2/2-way solenoid valves Type EV20B EV20B covers a wide range of direct-operated 2/2-way solenoid valves for universal use. EV20B is a very robust valve program with high performance
More informationMetal oil filler and air breather filler caps. Bayonet connection. Reservoir holes. TA46 B (Materials)
Metal oil filler and air Series T 46 4 5 6 4 ayonet connection Ø 46 7 8 46 Reservoir holes T46 (Materials) M5 - Cover: Chrome Plated Steel - Filter element: Impregnated paper Polyurethane 64-6 - Flange:
More informationA wide selection of pipe and orifice sizes is offered. Valves are available with threaded ports in brass and stainless steel.
Solenoid Valve Waterhammer-Free, 0- PSI /-Way; NPT - NPT; 0- PSI Advantages/Benefits Type 63 Waterhammer-free Low noise Zero differential pressure ompact design with high flow rates Low maintenance oil
More informationED 701 General Industry Pressure Transmitter
ED 701 General Industry Pressure Transmitter Standard industrial process connections Complete range of electrical connections 4... 20 ma and Voltage outputs Accuracy: 0.1%, 0.2% and 0.4% FS Quick response
More informationPressure Measurement. Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level 2/27
Overview Siemens AG 011 Function s are for measuring the liquid levels in wells, tanks, channels and dams. Diaphragm p Sensor U const. U + (brown) I EM I -1 (blue) 0, U B s are submersible sensors for
More informationPilot operated 2 port solenoid valve (general purpose valve) Standard specifications NC (normally closed) type C C. 2 /s) Starting
21/22 Series (general purpose valve) 21/22 Series NC (normally closed) type, NO (normally open) type Port size: Rc1 1/4 to Rc2, 32 to 50 flange iaphragm structure JIS symbol 21: Common specifications Item
More information4.2. Ex-Ceiling light fittings AB 80 / AB 05 LED / AB 05 / AB 12 NAV 70. (Zone 1, 2, 21, 22)
.2 Ex-Ceiling light fittings AB 8 / AB 5 LED / AB 5 / AB 12 NAV 7 (Zone 1, 2, 21, 22) The wall and ceiling light fixtures for particularly difficult operating conditions The impact-resistant and flameproof
More informationCartridge Valves Technical Information. Quick reference
Quick reference Contents CPF0... 8. CP600-5... 8. CP60-5... 8. 066 handle kit... 8.5 MP06... 8.6 MP... 8.6 X05-FD0 Traction manifold... 8.9 X05-FD6 Traction manifold... 8.0 X05-FD0 Traction manifold...
More information2.9. Namur Valves 2.9. page 175. Namur 1/4 also called Namur 1 in accordance to VDI / VDE Namur 1/2 also called Namur 2.
2.9 page 175 Namur 1/4 also called Namur 1 in accordance to VDI / VDE 3845. Namur 1/2 also called Namur 2. 2.9 Namur Valves + Selected models are available for low temperature application. Temperature-range:
More information/2 way valves (solenoid actuated diaphragm with forced lifting) 1/4... 2
/ way valves (solenoid actuated diaphragm with forced lifting) /4... Damped operation Operation without differential Suitable for vacuum igh flow rate For systems with low or fluctuating Brass body Wide
More informationFlow rates to 590 l/min
LM 400-40 - 4 Maximum pressure bar Flow rates to 590 l/min Technical data housing (Materials) ead: nodized luminium ousing: nodized luminium Manifolds: Steel - Painted black ypass valve: Steel -way ball
More informationCheck-Q-meter. Table of contents. Features. Functions. RE 27551/ /10 Replaces: Type FD
Check-Q-meter RE /0.0 /0 Replaces: 09.9 Type FD Nominal size... Series ax. Operating pressure 0 bar ax. Flow 0 l/min K9/ Table of contents Contents Page Features Functions Ordering details Symbols Functional
More informationDMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm
DMP P Industrial Pressure Transmitter Process Connections With Flush Welded Stainless Steel accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 % FSO Nominal pressure from 0... 00 mbar up
More informationDS 200P. Electronic Pressure Switch. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm
Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm accuracy according to IEC 600: standard: 0. % FSO option: 0. % FSO Nominal pressure from 0... 00 mbar up to 0... 0 bar
More informationSANMUR CONTROLS PVT. LTD.
Decide with confidence NMUR CONTROLS NMUR CONTROLS PVT. LTD. An ISO 900:008 Certified Company The name NMUR has been synonymous with reliability and quality in terms of products, services and systems integration.
More informationMaximum pressure 420 bar Flow rate to 152 l/min. 560 bar. 140 l/min. Flow rate l/min FMM 050 1/2 1,50 3/4 1,00. Δp bar 0,50 0,00 FHA 051 1,50 1,00
FMM 00 Maximum pressure 0 bar Flow rate to l/min FHA 0 Maximum pressure 60 bar Flow rate to 0 l/min Technical data FMM 00 Filter housing (Materials) Head: Cast iron (chemical heat treatment) Housing: Steel
More informationWorking pressure. 420 bar. Style T. Style B. Style D Style V Style Z. Style S B B D.I. D.I. D.I. D.I. D.I. D.I.
5 FP SRIS FP Working pressure 40 bar Style S Style Style T Style D Style V Style Z 5 Technical data Filter body (Materials) ead: Cast iron (chemical heat treatment) ousing: Steel (chemical heat treatment)
More informationLO1 SERIES. compact direct solenoid actuated valves
SRS compact direct solenoid actuated valves 0 d i r e c t s o l e n o i d a c t u a t e d v a l v e s T N T................................................... V V O S T O N........................................
More informationSize A DIN EN
Size A DIN EN 70-0 Actuators 0 series DIN EN 70-0 +, + ow and high housing Degree of protection IP6 Wired versions Moulded versions Degree of protection IP67 Contacts Thread Cable outlet Ordering-No. Female
More informationTransmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level
Overview Function s are for measuring the liquid levels in wells, tanks, channels and dams. Sensor Diaphragm p U const. U +2 (brown) I EM I - (blue) 0, U B s are submersible sensors for hydrostatic level
More informationPressure transmitters for industrial applications MBS 32 and MBS 33
Data sheet Pressure transmitters for industrial applications MBS 32 and MBS 33 The standard pressure transmitters MBS 32 and MBS 33 are designed for use in almost all industrial applications, and offer
More informationAIR BREATHER FILTERS. Temperature from -25 to +100 C
IR BRETHER FILTERS The comprehensive series of breather filters makes it possible to meet all market demands. Metal and plastic styles suitable for use on mobile equipment are available. The function of
More informationDMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm
DMP Pi Precision Pressure Transmitter pressure ports and process connections with flush welded stainless steel diaphragm accuracy according to IEC 600: 0, % FSO Nominal pressure from 0... 00 mbar up to
More informationVDN2.. VEN2.. VUN2.. Radiator valves. Building Technologies HVAC Products ACVATIX TM. NF norm, for 2-pipe heating systems
06 EN - Straight valves VDN.. Angle valves VEN.. Reverse angle valves VUN.. ACVATIX TM Radiator valves NF norm, for -pipe heating systems VDN.. VEN.. VUN.. Valve bodies made of brass, mat nickel-plated
More informationInstallation guide 862 MIT / MIR
Installation guide 862 MIT / MIR in combination with: 864 MTT or 863 MRT or (dual) spot element November 2005 Part no. 4416.232_Rev3 Enraf BV PO Box 812 2600 AV Delft Netherlands Tel. : +31 15 2701 100
More informationAIR PREPARATION. ELECTRONICALLY CONTROLLED PRESSURE REGULATING VALVE (PROPORTIONAL PRESSURE REGULATING VALVE) SERIES control
AIR PREPARATION ELECTRONICALLY CONTROLLED PRESSRE REGLATING ALE (PROPORTIONAL PRESSRE REGLATING ALE) SERIES control Description Abb. Port size Recommended Type Data Sheet No. flow (l/min)* airfit tecno
More informationC Electrical Connector Subsea / Underwater / Marine
www.r-marine.com Tel: + 0 ax: + 0 0 mail: sales@r-marine.com lectrical onnector Subsea / Underwater / Marine The most common applications: ROV ive ell onnectors Underwater ameras and Lights Underwater
More informationElement description. Multipass test in compliance ISO Contaminant ISO MTD. A - Microfibre
Style FZ Stainless Steel Pressure filter Technical data element Style In-Line filter: FZ 00-0 FZP 0 FZ 0 FZP 6 FZX 0 Manifold mounting: FZ 0 FZM 0 Max. working pressure: 700 bar Max. working pressure:
More information4.13. Ex-Floodlights of the series FMV LED / NSSFMV. (Zone 2, 22) service life and a high level of efficiency. NFMV floodlights for highpressure
.13 Ex-Floodlights of the series / (Zone 2, 22) The powerful LED floodlights FMV LED The new series of energy-saving FMV floodlights in LED technology are ideal for all general lighting applications in
More informationHigh Pressure fi lters. FHB series. Maximum working pressure up to 32 MPa (320 bar) - Flow rate up to 485 l/min
High Pressure fi lters FHB series Maximum working pressure up to MPa (0 bar) - Flow rate up to 8 l/min High Pressure fi lters Introduction FILTER SIZING INDEX CALCULATION CORRECTIVE FACTOR Page Introduction
More informationCipriani Harrison Valves Corp.
Butterfly Valve pplication Stainless steel hygienic butterfly valves are used in process piping systems for isolation and control. Butterfly valves operate either manually or automatically. Working Principle
More informationPressure Measurement Single-range transmitters for general applications
Siemens AG 07 Overview Function SITRANS LH00 Transmitter for hydrostatic level U const. p U I EM Sensor Connection for auxiliary power supply Vent pipe with humidity filter Protective conductor connection/
More information4/4-way servo solenoid directional control valves, directly operated, with electrical position feedback and on-board electronics (OBE)
4/4-way servo solenoid directional control valves, directly operated, with electrical position feedback and on-board electronics (OBE) RE 9035/. Replaces: 05. 1/1 Type 4WRPEH 6 Size 6 Unit series X Maximum
More informationPolígono Indutrial O Rebullón s/n Mos - España -
FP 5 Polígono Indutrial O Rebullón s/n. 646 - Mos - spaña - rodavigo@rodavigo.com SRIS FP Working pressure 40 bar Style S Style Style T Style D Style V Style Z 5 Polígono Indutrial O Rebullón s/n. 646
More informationUniversal type Port size: M5, Rc1/8, Rc1/4. Max. working. pressure
irect acting port solenoid valve for compressed air, manifold (special purpose valve) Series Universal type Port size: M, Rc/, Rc/ Refer to nding for more details. JIS symbol ommon supply / common exhaust
More informationHigh Pressure fi lters. FHA 051 series. Maximum working pressure up to 56 MPa (560 bar) - Flow rate up to 140 l/min. High Pressure fi lters
High Pressure fi lters FHA 0 series Maximum working pressure up to 6 MPa (60 bar) Flow rate up to 0 l/min 99 High Pressure fi lters Introduction FILTER SIZG DEX CALCULATION CORRECTIVE FACTOR Page Introduction
More informationEx-Floodlights of the series FMV LED / NFMV / NSSFMV. Stainless steel NSSFMV floodlights for particularly. in harsh environments
.13 Ex-Floodlights of the series / / (Zone 2, 21, 22) The powerful LED floodlights FMV/nFMV LED The new series of energy-saving FMV floodlights in LED technology are ideal for all ge neral lighting applications
More informationApplication PN 16 / 40 DN Product features. Compact overall height Body shape gives optimum flow characteristic
pplication Control of gases, vapours and liquids. The modular concept of valve, multi spring actuator and digital FOXBORO/Eckardt positioner Type SRD 992 facililates trouble free expansion to allow for
More informationLMP 210. Style B. Style S. Maximum pressure 60 bar F l o w r a t e s t o l / m i n
LMP 0 Style S Style Maximum pressure 60 bar F l o w r a t e s t o 7 0 l / m i n 6 Technical data Filter housing (Materials) Head: luminium Housing: nodised luminium ypass valve: Nylon - Steel Pressure
More informationVISUAL LEVEL INDICATORS
VIUL LEVEL INDICTOR LV... The level indicators series is available for both static and mobile applications; the construction materials used make it possible to guarantee service with wide temperature variations
More informationCooling Water Flow Regulator
Temperature controlled, indirectly and directly actuated diaphragm valves / seat valves Port size G 3/8 to G DN 0 to DN 0 ontinuous regulation High accuracy No auxiliary energy required Technical data
More information4.3. Ex-Pendant light fittings AB 50 / SPG 1N / AB 51 / EVI 200 / EVI 500 / EV35 LED. (Zone 1, 2, 21, 22)
.3 Ex-Pendant light fittings AB 5 / SPG 1N / AB 51 / EVI 2 / EVI 5 / EV35 LED (Zone 1, 2, 21, 2 The pendant light fitting series for a wide variety of applications The explosion-protected pendant light
More informationBulkhead Fitting Product Guide
1/2" TO 3" PV OMPRSSION FITTING * oes not come with bulkhead fitting MTRILS Robust PV Upper and Lower ody onstruction PV ell lass 12454 per STM 1784 Stainless Steel Wave Spring 17-7 PH Stainless Steel Fits
More informationSERIES FMP. Working pressure. 280 bar. Style D Style V Style Z. Style T. Style B. Style S B B D.I. D.I. D.I. D.I. D.I. D.I.
6 FMP SERIES FMP Working pressure 80 bar Style S Style Style T Style D Style V Style Z 7 Technical data Filter body (Materials) ead: Cast iron (chemical heat treatment) ousing: Cast iron (chemical heat
More informationFlow rates to 485 l/min
FB Maximum pressure 0 bar Flow rates to 8 l/min Technical data Filter housing (Materials) ead: Cast iron (chemical heat treatment) ousing: Steel (chemical heat treatment) Bypass valve: Steel Check valve:
More informationFMM 050 uk :26 Pagina 5 (1,1) FMM 050
uk 6-07-006 9:6 Pagina 5 (,) 30 uk 6-07-006 9:6 Pagina 5 (3,) SRIS Working pressure 80 bar Style S Style Style T Style D 3 uk 6-07-006 9:6 Pagina 7 (,) Technical data Filter body ( M a t e r i a l s )
More informationSwitches in conformity with ATEX directive
E Switches in conformity with ATEX directive page / General Catalog 09-0 Technical concepts page /9 A B Position switches FD series page / Category Zone Approvals Article code extension G M ATEX category
More informationReturn fi lters. MPI series. Maximum working pressure up to 1 MPa (10 bar) - Flow rate up to 3000 l/min
Return fi lters series Maximum working pressure up to MPa (0 bar) Flow rate up to 000 l/min 0 Return fi lters Introduction FILTER SIZING INDEX CALCULATION CORRECTIVE FACTOR Page Introduction Calculation
More informationDMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm
DMP Pi Precision Pressure Transmitter pressure ports and process connections with flush welded stainless steel diaphragm accuracy according to IEC 600: 0, % FSO Nominal pressure from 0... 00 mbar up to
More informationAIR BREATHER FILTERS. Temperature from -25 C to +100 C
IR RETHER FILTERS The comprehensive series of breather filters makes it possible to meet all market demands. Metal and plastic styles suitable for use on mobile equipment are available. The function of
More informationISO mm ISO mm. Nl/min. Nl/min. Nl/min. Nl/min. ISO /2 Distributors. ISO Interface. OVERSIZED interface (UNIVER original)
ISO 154071/ Distributors E Integrated electrical connection (ISO 15407/) B M1 connector (Automotive) A Single electrical connection (ISO 15407/1) A Pneumatic connection (ISO 15407/1) ISO 0 ISO Interface
More informationWorking pressure. 320 bar. Style T. Style D. Style S. Style B B B D.I. D.I. D.I. D.I.
8 FB SERIES FB Working pressure 0 bar Style S Style B Style T Style D B B B B D.I. D.I. D.I. D.I. A A A A 8 Technical data Filter body (Materials) ead: Cast iron (chemical heat treatment) ousing: Steel
More informationField IT 50T Series Transmitters
Data Sheet SS/G/A_ Field IT 0T Series Transmitters gauge/absolute pressure transmitter Ranges: -00 to 0000kPa - to 00bar -. to 6000psi Base accuracy : 0.% (BFSL) Chemical Vapour Deposition (CVD) technology
More informationNormally Closed (N.C.), Normally Open (N.O.), Common (C.O.)
Series VVX// The models VX// have been revised. For details, please refer to catalog no. ES0-A. Similar updating Normally Closed (N.C.), Normally Open (N.O.), Common (C.O.) Courtesy of Steven Engineering,
More informationGeneral Specifications
General Specifications Model PR10 ph Retractable fitting On-line measurements always present extra challenges compared to at-line measurements. For example when maintenance needs to be done. pplications
More informationAmphenol. Amphenol-Tuchel Electronics GmbH. Circular Connectors C 091 A/B/D Series
Amphenol Amphenol-Tuchel Electronics GmbH Circular Connectors C 09 A/B/D Series The Company Amphenol-Tuchel Electronics GmbH is a member of the USA based Amphenol Corporation. With our own global presence
More informationSolenoid valve Types EVR 2 - EVR 40
Data sheet Solenoid valve s EVR 2 - EVR 40 EVR is a direct or servo operated solenoid valve for liquid, suction, and hot gas lines with HCFC and HFC refrigerants. EVR valves are supplied complete or as
More informationFlow rates to 750 l/min
FP Maximum pressure 0 bar Flow rates to 70 l/min Technical data Filter housing (Materials) ead: Cast iron (chemical heat treatment) ousing: Steel (chemical heat treatment) Bypass valve: AISI L (FP 0-0)
More informationPressure Transmitter ED 701
Pressure Transmitter ED 701 Hygienic and industrial process connections Zero setting function Accuracy < 0.1% FS Quick response time < 25 ms High long-term stability Excellent repeatability Active compensation
More informationFlow rates to 485 l/min
FB Maximum pressure 0 bar Flow rates to 8 l/min Technical data Filter housing (Materials) ead: Cast iron (chemical heat treatment) ousing: Steel (chemical heat treatment) Bypass valve: Steel Check valve:
More informationHigh Pressure fi lters. FMP 039 series. Maximum pressure up to 110 bar - Flow rate up to 80 l/min. High Pressure fi lters
High Pressure fi lters FMP 09 series Maximum pressure up to 0 bar Flow rate up to 80 l/min 7 High Pressure fi lters FILTER SIZING The correct filter sizing have to be based on the variable pressure drop
More informationFlow rates to 485 l/min
FB Maximum pressure 0 bar Flow rates to 8 l/min Technical data Filter housing (Materials) ead: Cast iron (chemical heat treatment) ousing: Steel (chemical heat treatment) Bypass valve: Steel Check valve:
More informationConductivity sensor for hygienic applications
Conductivity sensor for hygienic applications Type 8221 can be combined with Perfect for demanding applications in the hygienic industry (CIP and SIP compatible) Variants available for usage over a wide
More informationSTAINLESS STEEL FILTER
STINLSS STL FILTR Style FZ Stainless Steel Pressure filter Technical data Style In-Line filter: FZ 00-0 FZP 0 FZ 0 FZP 6 FZX 0 Manifold mounting: FZ 0 FZM 0 Max. working pressure: 700 bar Max. working
More informationhard anodized aluminum extrusion die cast aluminium acetalic resin nickel plated steel die cast aluminium nitrile rubber stainless steel 3 Version
YR Pneumatic actuators for process automation Pneumatic connections configuration: NMUR interface V/VE Top pinion: V/VE Holes for sensor box connection: V/VE ottom holes for connecting valves: SO Single
More informationE X - C O N T R O L U N I T S A N D C O N T R O L S T A T I O N S
E X - C O N T R O L U N I T S A N D C O N T R O L S T A T I O N S EX- CONTROL UNITS AND CONTROL STATIONS EX- INSTALLATION SWITCH.. EX- CONTROL STATIONS INDIVIDUAL EX- CONTROL STATIONS.. 0 EX- CONTROL AND
More informationReturn fi lters. FRI series. Maximum pressure up to 20 bar - Flow rate up to 1500 l/min. Return fi lters
Return fi lters FRI series Maximum pressure up to 0 bar - Flow rate up to 500 l/min 9 Return fi lters FILTER SIZING The correct filter sizing have to be based on the variable pressure drop depending by
More informationMX Series COMPACT AND USER FRIENDLY. Metal Tube Type Variable Area Flowmeter OUTLINE STANDARD SPECIFICATION MODEL CODE MX-400, MX-71 MX-52E
OMPT ND USER FRIENDLY MX Series Metal Tube Type Variable rea Flowmeter OUTLINE MX Series flowmeter is the metal tube type variable area flowmeter having the unified face-to-face dimension. The compact
More informationPolígono Indutrial O Rebullón s/n Mos - España -
FB 8 Polígono Indutrial O Rebullón s/n. 646 - Mos - España - rodavigo@rodavigo.com SERIES FB Working pressure 0 bar Style S Style B Style T Style D B B B B D.I. D.I. D.I. D.I. A A A A 8 Polígono Indutrial
More informationSolenoid valves Type EVR 2 g 40 NC/ NO New EVR 6 with Steel cover design
MAKING MODERN LIVING POSSIBLE Technical brochure Solenoid valves EVR 2 g 40 NC/ NO New with Steel cover design EVR is a direct or servo operated solenoid valve for liquid, suction, and hot gas lines with
More informationSuction fi lters. SF series. Flow rate up to 160 l/min. Suction fi lters
Suction fi lters SF 00 series Flow rate up to 60 l/min Suction fi lters FILTER SIZING The correct filter sizing have to be based on the variable pressure drop depending by the application. For example,
More informationSolenoid valves Type EVUL
Data sheet Solenoid valves EVUL EVUL solenoid valves are designed to fit into compact refrigeration systems. Available in servo operated versions they can be applied in liquid, suction, and hot gas lines.
More informationVALVES B D E B D A. ISO /2 Valves CHARACTERISTICS CODIFICATION KEY. BD 18 mm. BD 26 mm
BD ISO 15071/ Valves CHARACTERISTICS Ambient temperature Fluid Commutation system Max pressure Connections Nominal bore (mm) Nominal flow rate (Nl/min) Valve body Seals Spool Electropilot/Coil Voltage
More informationFlow rates to 475 l/min
FMP Maximum pressure 0 bar Flow rates to 7 l/min Technical data PRSSUR FILTR Filter housing (Materials) ead: Cast iron (chemical heat treatment) ousing: Steel (chemical heat treatment) Bypass valve: Brass
More informationFlow rates to 750 l/min
FP Maximum pressure 0 bar Flow rates to 70 l/min Technical data Filter housing (Materials) ead: Cast iron (chemical heat treatment) ousing: Steel (chemical heat treatment) Bypass valve: AISI L (FP 00-0)
More information29 188/ way Proportional Flow Control Valve Model 2 FRE 6./.,Series 2X. Ordering Code: Proportional Flow Control Valve 2 FRE 6 2X K4 V *
-way roportional low Control Valve Model RE./.,Series X Size... SI ( bar).... GM ( L/min) R 9 88/.98 R 9 88/.98 Replaces:.9 With pressure compensator for the control of an oil flow independent of pressure
More informationAmphenol. Amphenol-Tuchel Electronics GmbH. Series C 146 Heavy Duty Connectors Core Programme
Amphenol Amphenol-Tuchel Electronics GmbH Series C 146 Heavy Duty Connectors Core Programme The Company General information These connectors are designed and produced in conformity with the voltage directive
More informationI nllk 08018/18 I nllk I nllk 08036/36 I nllk I I nllk 08058/58 I
I nllk / I x W x W x W x W x W Technical data Cooper Crouse-Hinds - all rights reserved nllk / nllk nllk / nllk nllk / Marking to //EC II G Ex na II T / II D td A IP T C EC Conformity Statement PTB ATEX
More informationPRESSURE GAUGE SELECTORS
PRESSURE GUGE SELECORS Gauge isolator valves are designed to protect pressure gauges from pressure shocks when the pressure reading is not required; after each reading setting the selector to the closed
More informationAbsolute encoders multiturn
elektronischer electronic multiturn, Multiturn, magnetic magnetisch Sendix M66 / M68 (shaft / hollow shaft) The Sendix M6 with Energy Harvesting Technology is an electronic multiturn encoder in miniature
More informationPN LINE. PN Line. PX Line. PA Line. PU Line PX LINE. PV Line PA LINE & TUBINGS PU LINE PV LINE. Brass Push-in fittings
I NDEX PV LINE PX LINE PU LINE PA LINE & TUBINGS PN LINE Brass Push-in fittings Stainless Steel Push-in fittings Brass Standard fittings and Flexible Hoses Couplings and Multiple Connectors Function fittings
More information2-way proportional throttle valve for block installation
-way proportional throttle valve for block installation Types FES; FESE Sizes to Component series X Maximum operating pressure bar Maximum flow 800 l/min at Δp = 0 bar Table of contents Contents Page Features
More information387 Low & Medium Pressure filters
Low & Medium Pressure fi lters LMD 000 & series Maximum pressure up to 6 bar Flow rate up to 90 l/min 87 Low & Medium Pressure filters FILTER SIZING The correct filter sizing have to be based on the variable
More informationSOLENOIDS/COILS & ACCESSORIES calculations basic design considerations and coil identifi cation
SOENODS/OS & ESSOES calculations basic design considerations and coil identifi cation TONS For direct acting solenoids we can calculate the solenoid pull force by means of the following rough equation:
More informationSerie B2.1. Flanged ductile iron ball valve. made in. Application fields. Shut-off valves E U R O P E. 18
erie B. Flanged ductile iron ball valve BRanDOni made in E U R O P E Application fields WATER CONdITIONING GA EATING INdUTRY FIRE FIGTING www.brandoni.it erie B. eries B. valves are shut-off ball valves
More informationATEX/IECEx RTD temperature probe
Page 1/8 ATEX/IECEx RTD temperature probe with connecting cable acc. to DIN EN 60751 For temperatures from -100 to +600 C As single, double, or triple RTD temperature probe In two-wire, three-wire, or
More information