MODEL : TX Series (Nom. sizes 15mm to 400mm)

Size: px
Start display at page:

Download "MODEL : TX Series (Nom. sizes 15mm to 400mm)"

Transcription

1 iquid High performance and wide viscosity range EX TURBINE MODE : TX Series (Nom. sizes 15mm to 4mm) GENERA EX TURBINE is an industrial turbine meter for consistent and accurate liquid flow measurement. It offers a wide viscosity range and accepts flows even in low Reynolds number regions. The turbine meter is mainly applicable to flow measurement of petroleum products (white products), PG, and water. FEATURES 1. High viscosity version specially has a high metering accuracy even in low Reynolds number regions. 2. inearity within ±.15%, repeatability within ±.2% is available for transactions of applicable liquid. 3. Direct and remotely transmitted registration of total flow and instantaneous flowrate are provided meter sizes in nominal sizes from 15mm thru 4mm. GENERA SPECIFICATIONS Meter Body Item Description Model or ow viscosity or high viscosity Nominal size (mm) Connection Flange Connection (RF : St d) Flange rating JIS 1, 16, 2, 3K ASME/JPI 15, 3 Applicable fluid iquid (petroleum, PG, water, etc) rate See flow range table (page 3). Operating 3 to +12 C (Explosionproof : 2 to +12 C) Temp. High Temp. 3 to +35 C (Explosionproof : 2 to +29 C) Range ow Temp. 196 to +12 C ( 2) 1 to +12 C( 3) Max. Operating Pressure Depends on flange rating (see table below). inearity ( 1) ±.15% or ±.35% of RD Repeatability.5% ( 4) Body SCS14+SUS34 (nominal size 15mm only), SUS34 Support SUS34 Materials Rotor SUS63 SUS631 ( 5) SUS316+NAS64 (SUS329J4) ( 5) Bearings Super hard alloy Shaft Super hard alloy Installation Horizontal 1 : In case of analog output, ±.1% of FS is added. In order to secure specified accuracy, Piping instruction (page1) should carefully be observed. 2, 3 : ow temperature model is not of explosionproof. 4 : ±.2% with a flow straightener or Honey Vane (perforated plate flow straightener). 5 : The materials may differ depending on the specification. Flange Rating and Max. Operating Pressure (MPa) Operating Temp. Flange Rule JIS 1K JIS 16K JIS 2K JIS 3K ASME/JPI 15 ASME/JPI 3 Below 12 C Above 12 C, less than 3 C Head Office (Tokyo): Tel Fax International Sales Division SK1@oval.co.jp Overseas Branch Offices: Beijing, Netherlands, Seoul, Singapore, Taipei

2 Converter Specifications Item Description Model PA14 PA14S (Totalizer) Indicator (Option) Display:Total counter, with 8 digits CD Unit: Same as scaled pulse Counter reset by internal switch Output signal Current signal, 2-conductor (common with power lines) One of the following pulse types is selected: 1: Unscaled pulse type (single) ( 1) Pulse width : 2μs 2: Unscaled pulse type (double) Pulse levels Pulse width : 1μs []= 4mADC 3: Scaled pulse type [1]= 2mADC Pulse width : 5ms 4: Pulse type to be connected with exclusive receiver (E134) Pulse width : 2μs 5: Analog type, 4 to 2mADC at to FS Time constant : 2.5S (FS 2Hz) or 1S (FS<2Hz) Only one of type 1, 2, 3, 4 is available as output. Cable ( 2) Transmission length Power supply Electrical configuration Converter to receiving instrument: 1.25mm 2 min., 2-conductor shielded cable Finished cable outside diameter: Nonexplosion-proof ø13.5mm max. Flameproof ø8.5 to ø11mm Converter to receiving instrument:1km. max. 12 to 45V DC (See load resistance range curve.) G1/2 internal thread In the flameproof configuration for TIIS, the external cable lead-in is of pressuretight packing type (dedicated lead-in fitting furnished). (For T2/high temperature service, a pressuretight conduit screw-in type is acceptable.) For FM flameproof configuration, NPT 1/2 female adapter is fixed. For ATEX flameproof configuration, M2 female adapter is fixed. For NEPSI flameproof configuration, M2 female adapter is furnished. Explosionproof configuration Waterproof construction Ambient Temperature (Refer to the Fig. below.) Ambient humidity Material Finish Select one of the following: 1 Non-explosionproof configuration 5 Flameproof configuration ATEX: Ⅱ2G Exd ⅡC T4 Gb 2 Flameproof configuration TIIS: Exd ⅡB + H2 T4/T2 6 Flameproof configuration NEPSI: Exd ⅡB + H2 T4 Gb 3 Flameproof configuration FM-US: Class I Division 1 Group A, B, C&D T4 7 Flameproof configuration KOSHA: Exd ⅡB + H2 T4 4 Flameproof configuration FM-C: Class I Division 1 Group B, C&D T4 4 to +8 C (Explosionproof : 2 to +6 C) 5 to 1%RH without dew condensation Aluminum alloy Finished in baked melamine Munsell 1B8/4 (Cover: Munsell 2.5PB4/1) IP66 2 to +6 C 1 : Pulse type provides both single and double. Single pulse is standard. Double pulse type reduces test time when meter calibration with Small Volume Compact Prover is specified. 2 : In case of TIIS explosionproof type used under the ambient temperature of 5 or higher, use a cable resistant to the temperature of 7 or higher. Acceptable oad Resistance Range oad Resistance (Ω) Operating Region Supply Voltage (VDC) Ambient Temperature Range If fluid temperature exceeds 125 C, derate according to the diagram below. Ambient Temp. () 8 Nonexplosionproof Spec W/Displayer and Explosionproof Fliid Temperature () Output Signal Units and Display Units Nominal size mm (inch) Max. rate m 3 /h ( 3) Meter factor /P Pulse output frequency (Hz) ( 4) Units of scaled pulse output and total counter for PA14 and PA14S Single Double Single Double Min. St d Max. 15 ( 1 /2) Q 238Q 1/P 1/P 1/P 2 ( 3 /4) Q 117Q 1/P 1/P 1/P 25 (1) Q 72.2Q 1/P 1/P 1/P 4 (1 1 /2) Q 3.6Q 1/P 1/P 1m 3 /P 5 (2) Q 18.3Q 1/P 1/P 1m 3 /P 8 (3) Q 7.Q 1/P 1/P 1m 3 /P 1 (4) Q 2.94Q 1/P 1/P 1m 3 /P 15 (6) Q 3.89Q 1/P 1m 3 /P 1m 3 /P 2 (8) Q 1.83Q 1/P 1m 3 /P 1m 3 /P 25 (1) Q 1.15Q 1/P 1m 3 /P 1m 3 /P 3 (12) Q.889Q 1/P 1m 3 /P 1m 3 /P 35 (14) Q.556Q 1/P 1m 3 /P 1m 3 /P 4 (16) Q.35Q 1m 3 /P 1m 3 /P 1m 3 /P 3 : Intermittent flow. 4 : Output frequency in each flowrate is calculated by substituting flowrate Q (m 3 /h). : Output signal 5 in the last digit of product code represents unscaled double pulse output frequency 2 times higher than unscaled single pulse frequency.

3 FOW RANGES range of the meter varies with temperature and viscosity of liquid to be metered. The following tables 1 to 3 should be refereed to in determining respective flow range. Table 1: ( type Nom. sizes 15 to 5mm for viscosity above.3mpa s or nom. sizes 8 to 4mm for kinematic viscosity below 2mm 2 /s, and nom. sizes 8 to 4mm for high temperature service) Unit in m 3 /h Temp. range Min. rate Nominal size inearity ±.35% mm inearity ±.15% Max. rate A B A B Intermittent Continuous ν ν ν ν to ν ν ν ν ν ν ν ν ν ν ν ν ν ν to ν ν ν ν ν ν ν ν Table 2: High viscosity version Applicable nominal sizes 8 to 4mm above 2 to 3mm 2 /s in viscosity Temp. range 1 to +35 Unit in m 3 /h Min. rate inearity ±.35% inearity ±.15% Max. rate A B A B Intermittent Continuous ν ν ν ν ν ν ν ν ν ν ν ν ν ν ν ν Nominal size mm Table 3: ow temp. version & High temp. version Nominal sizes: 15 to 5mm Temp. range 196 to 3 or 12 to 35 Unit in m 3 /h Min. rate Nominal size inearity ±.35% mm inearity ±.15% Max. rate A B A B Intermittent Continuous ν ν ν ν ν ν ν ν ν ν Table 4: (ow viscosity type In an application where viscosity is below.3mpa s or accuracy is ±.15% in standard type, when a greater low end flowrate is required, applicable nominal sizes are 15 to 5mm.) Temp. range 3 to +12 Unit in m 3 /h Min. rate Nom. size inearity ±.2% mm Max. rate A B Intermittent Continuous : ν represents kinematic viscosity (mm 2 /s) of liquid to be metered. 2 : arger value in either column A or B is specified. 3 : Not available when kinematic viscosity is high and the value in B of min. flowrate exceeds max. continuous flowrate. 4 : For nominal sizes 8 to 4mm for viscosities 2 to 3mm 2 /s, consult the factory. 5 : Intermittent flow indicates operation within 8 hrs/day. 6 : ow end flowrate in the ±.35% accuracy, low viscosity model is the same as the standard type. 7 : Accuracy specifications ±.35% and ±.15% are independent of each other. Hence, a single flowmeter cannot handle flow ranges of ±.35% and ±.15%.

4 PERFORMANCE CHARACTERISTICS PRESSURE OSSES Nominal sizes: 15 to 5mm P water 1 Pres. loss kpa Nom. size: 15mm 2mm 25mm 4mm 5mm Water: ( Specific gravity 1g/m Viscosity 1mm 2 /s To obtain actual ΔP for liquids other than water, the following equation is used: ΔP = ΔP ρ ν.25 (kpa) where: ΔP : iquid pressure loss to be metered ΔP : The value that read from the left ghaph ρ : iquid density to be metered; g/m ν: Kinematic viscosity; mm 2 /s rate m 3 /h Nominal sizes: 8 to 4mm 6 4 P water 25mm (1 ) 3mm (12 ) 35mm (14 ) 4mm (16 ) Pres. loss kpa Nom. size: 8mm (3 ) 1mm (4 ) 15mm (6 ) 2mm (8 ) Water: ( Specific gravity 1g/m Viscosity 1mm 2 /s To obtain actual ΔP for liquids other than water, the following equation is used: ΔP = ΔP ρ ν.25 (kpa) where: ΔP : iquid pressure loss to be metered ΔP : The value that read from the left ghaph ρ : iquid density to be metered; g/m ν: Kinematic viscosity; mm 2 /s rate m 3 /h

5 PERFORMANCE CHARACTERISTICS Meter Error (Nominal size: 25mm (1 )) Meter error characteristics curve +.2 Meter error (%) rate m 3 /h Meter factor: 7.352m/P ength of Straightening pipe: 5 x D : Gasoline : Kerosene D = Nominal size Meter error (%) Meter error Re. No. characteristics curve Reynolds No. Meter factor: 7.352m/P ength of Straightening pipe: 5 x D : Gasoline : Kerosene D = Nominal size Meter error (%) Type (Nominal size: 15mm (6 )) Meter error characteristics curve rate m 3 /h Meter error Re. No. characteristics curve Kerosene (1.5mm 2 /s) Gasoline (.57mm 2 /s) Nominal size: 15mm ength of flow straightening pipe: Straightening pipe 8D + straightener (D = Nominal size) Meter error (%) Reynolds No. Kerosene (1.5mm 2 /s) Gasoline (.57mm 2 /s) Nominal size: 15mm ength of flow straightening pipe: Straightening pipe 8D + straightener (D = Nominal size) High Viscosity Type (Nominal size: 15mm (6 )) Meter error characteristics curve Meter error (%) rate m 3 /h Kerosene (1.5mm 2 /s) Fuel Oil (48.6mm 2 /s) Nominal size: 15mm ength of flow straightening pipe: Straightening pipe 8D + straightener (D = Nominal size) Meter error Re. No. characteristics curve Meter error (%) Reynolds No. Kerosene (1.5mm 2 /s) Fuel Oil (48.6mm 2 /s) Nominal size: 15mm ength of flow straightening pipe: Straightening pipe 8D + straightener (D = Nominal size)

6 HOOK-UP WITH RECEIVING INSTRUMENTS Converter or compensator (temp./press. compensator provided) (E84 ) E8 series 4 to 2mADC Analog 1 to 5VDC output Pulse output to totalizer 1: Unscaled pulse (Single) Totalizer (E122) 3: Analog 2: Scaleded pulse OVA MODE E4 computer (E41 series) Power supply (SU153) (4 to 2mADC) Recorder Output signal: 1: Unscaled pulse (single) 2: Scaled pulse 3: Analog One output from 1, 2, 3 is chosen. Totalizer (E122) NOTES: 1. Shown above are typical examples. Depending on individual applications and specifications, hookup with many other electrical instruments is possible. 2. For arrangement with any electrical instrument, indicator, etc. other than those supplied by OVA, a 12 to 45VDC power supply is required. Use OVA Model SU153 power supply unit. 3. As to individual receiving instruments, see respective general specification sheets. * Current Pulse Output Unscaled and scaled pulse output levels are [1]: 2mADC and []: 4mADC. 2mADC 4mADC If you plan to use any instrument designed to accept a voltage pulse signal, couple a resistor in series as shown to furnish a voltage pulse. madc R Power supply (SU153) 24V DC Receiver of other maker Resistance (R) [1] [] 25Ω 5VDC 1VDC 1Ω 2VDC.4VDC The upper limit 6Ω on a 24VDC power supply. (Refer to the page 2.) Turbine meter

7 PRODUCT CODE EXPANATION Item Code No Model T X EX Turbine Type Nominal size Material Flange rating Operating temp. range 1 Description 2 ow viscosity version (Max..3mPa s) Nominal size 15 to 5mm 5 High viscosity version (Min.2 to 3mm 2 /s) Nominal size Min. 8mm 9 Other than above mm ( 1 /2") 2 2mm ( 3 /4") mm (1") 4 4mm (1 1 /2") 5 5mm (2") 8 8mm (3") 1 1mm (4") mm (6") 2 2mm (8") mm (1") 3 3mm (12") mm (14") 4 4mm (16") D SUS34 ( 1) Z Other than above 1 JIS 1K RF 2 JIS 16K RF 3 JIS 2K RF 4 JIS 3K RF 5 ASME 15 RF 6 ASME 3 RF 7 JPI 15 RF 8 JPI 3 RF 9 Other than above 1 ( 3 to +12 C) 2 High temp. Version ( 3 to +35 C) 3 ow temp. Version ( 196 to 3 C) Nom. size: 15 to 5mm 9 Other than above 1 PA14 (No display) Converter 4 PA14S (w/totalizer) ( 2) 9 Other than above 1 Non-Explosionproof 5 Flameproof (TIIS) 6 Flameproof (FM) ( 3) Explosionproof configuration 7 Flameproof (NEPSI) ( 3) 8 Flameproof (KOSHA) ( 3) A Flameproof (ATEX) ( 3) 1 Unscaled pulse (Single) 2 Scaled pulse 3 Analog Output signal 5 Unscaled pulse (Double) 8 Unscaled scaled pulse (Combined with exclusive register) 9 Other than above 1 : Meter body for nominal size 15mm is a combination of SCS14A and SUS34. 2 : Available only for both unscaled pulse (single, double) and scaled pulse. 3 : Available only within the standard operating temperature range.

8 OUTINE DIMENSIONS [Unit in mm] Standerd model Figures in brackets show the dimensions with built-in display Conduit connection G 1 /2 High viscosity model, ow viscosity model Conduit connection G 1 /2 Conduit connection G 1 /2 Conduit connection G 1 /2

9 Converter w/pa14s Dimensions are similar to w/pa14 8 digits CD Totalizer PA14S PA14S w/totalizer is installed so that the cable entry points in the flow inlet direction. PA can be oriented in any direction in 9 steps. Refer to the instruction manual if changing the flow direction is desired. Nominal size (mm) Temp. class ød (JIS 1K) (mm) H (mm) Approx. Weight (kg) No direct reading register w/direct reading register High Tp., ow Tp High Tp., ow Tp High Tp., ow Tp High Tp., ow Tp High Tp., ow Tp High Tp High Tp High Tp High Tp High Tp High Tp High Tp High Tp

10 INSTAATION CONDITIONS 1. piping instructions (for ±.35% RD class) For the design performance of EX Turbine, it is necessary to obtain uniform flow pattern of metering fluid upstream and downstream of the meter. The following piping arrangement guidelines should be observed depending on your desired linearity (within ±.15% or ±.35%). When controlling the linearity within ±.35%, use OVA flow straightener or use the specified straight pipe (compliant with API Chapter 5 Section 3). No. Piping Arrangement Straight Pipe ength () D = Nom. size Remarks 1 OVA s flow straightener Honey Vane S Honey Vane 8D Refer to Honey Vane on page 11. Applicable to Nom. size >25mm Straightener 12D Refer to GS.No GCF1. 2 Reducer 15D min. A concentric reducer is upstream of the meter. 2D min. An elbow is upstream of the meter. 3 Elbow 25D min. Two elbows are vertically upstream of the meter. 4D min. Two elbows are horizontally upstream of the meter. Opened 4 Fully open valve 15D min. A fully open valve is upstream of the meter. Partially Opened 5 Partially open valve 5D min. A partially open gate valve, sharp orifice, or something that markedly disturbs the flow pattern is upstream of the meter. Notes 3: 1) Sch.4 pipe is used as the standard material in the list. Therefore use Sch.4 pipe as the standard pipe. 2) Downstream of the meter, be sure to install 5D straight pipe. 3) Pressure or temperature detector shall be located downstream of the meter as shown in Fig. 3. Piping example for linearity ±.15%, repeatability ±.2% 4 to 6.5D 2 to 4.5D Press. Tap Temp. Tap 8D Upstream pipe 12D Straightener EX Turbine 5D Down stream pipe EX Turbine D=Nominal size 8D 8D 5D Upstream pipe D=Nominal size Honey Vane EX Turbine Down stream pipe 1

11 2. Requirements of backpressure for EX Turbine As the flow velocity increases in EX Turbine, cavitation could be produced. By cavitation, a meter error could also shift to + side and fluctuate considerably. In order to prevent this, it is required to maintain a constant backpressure. Thus, API-MPMS Chapter 5 Section 3 specifies the required of backpressure in the following equation: PB 2ΔP Po (MPa [absolute]) P B : Back pressure (Pressure at downstream pipe outlet) ΔP : Pressure loss (MPa) Po : Vapor pressure of liquid to be metered. (MPa [absolute]) 3. Strainer Install a strainer upstream of the meter to prevent the meter from damage with foreign solids. Where nominal size of EX Turbine is smaller than the piping nominal size, select a strainer having the same diameter as that of the pipeline. (Usually, flow velocity in a strainer should be controlled to less than 4 to 5m/sec and the pressure to less than 29.4kPa). Nominal sizes and net mesh are specified as follows: 5. Air Eliminator If any quantity or bubble is present in the liquid, metering error could considerably increase being not negligibly small. For this reason, installation of OVA air eliminator upstream of the meter is recommended. 6. agging (heat insulation) Work If heat insulation is considered for the piping, simplified lagging (without mortar finish, for example) is suggested for areas where the turbine meter is installed to facilitate disassembly and inspection. Such considerations will permit removing the flowmeter connecting bolts without the need of breaking the coat of lagging material each time at servicing. Bolts ready to be taken off by removing lagging Simple lagging (split design suggested) Pipeline lagging Nominal Size (mm) Type Hi Viscosity Type 15 to 8, 1 6 mesh 15 4 mesh 6 mesh arger than 2 2 mesh Span Flange nuts on both ends ready to be taken off 4. Honey Vane Dimensions Honey Vane S Honey Vane Nom. size φd ( 1) (mm) (mm) t (mm) (mm) : JIS1K : Consult factory for larger than nominal size 35. t D Honey VaneS Honey Vane 11

12 When making inquiries, please advise the following: (Fill in blanks or check with mark). 1. Application 2. Fluid to be metered 3. range (m 3 /h) Max. Normal Min. 4. Nominal size mm inch 5. Temp. range ( C) Max. Normal Min. 6. Pressure range Max. Normal Min. MPa 7. Density or Sp. Gr. Density kg/m 3 Sp. Gr. 8. Flange rating 9. straightener Req d Not req d 1. Converter 11. Output signal Model : PA14 PA14S Explosionproof configuration : Non-explosionproof Flameproof Combination explosionproof (PA14S) Unscaled pulse Scaled pulse Pulse unit /P Analog output Full scale to /h 12. Receiving instrument Direct-coupled CD counter Arrangement with receiving instruments 13. Miscellaneous The specification as of December, 214 is stated in this GS Sheet. Specifications and design are subject to change without notice. Sales Representative: GS.No.GBT13E 初版改訂印刷 Strada Antica di None, 28/a Orbassano (TO) Tel: Fax: info@asitinstruments.it

DELTA FLOWMETER FOR GAS SERVICE (INSERTION TYPE) MODEL VF SERIES

DELTA FLOWMETER FOR GAS SERVICE (INSERTION TYPE) MODEL VF SERIES DETA FOWMETER FOR GAS SERVICE (INSERTION TYPE) MODE VF SERIES GENERA SPECIFICATION GS. No. GBD0-0-E GENERA In the thermistor type Delta meter, a probe inserted in the pipeline detects the representative

More information

MODEL: CR002, CR003, CR004. ADC12 Display shield. Liquid (Density range: 0.3 to 2.0g/mL) Operating temperature range

MODEL: CR002, CR003, CR004. ADC12 Display shield. Liquid (Density range: 0.3 to 2.0g/mL) Operating temperature range Liquid Inexpensive Microflow Coriolis Flowmeter CoriMate Ⅱ MODEL: CR002, CR003, CR004 GENERAL Based on the knowledge and experience on Coriolis technologies OVAL has gained over many years, the Corimate

More information

ULTRA OVAL Meter Sizes:39, 41, 45, 50, 52, 53 w/unfactored Pulse Generator (NPG60A)

ULTRA OVAL Meter Sizes:39, 41, 45, 50, 52, 53 w/unfactored Pulse Generator (NPG60A) ULTRA OVAL Meter Sizes:9, 4, 45, 50, 5, 5 w/unfactored Pulse Generator (NPG60A) GENERAL SPECIFICATION GS.No.GBU0--E GENERAL ULTRA OVAL MODEL 9, 4, and45 provides extensive capability as a highly dependable

More information

Applicable Fluid. Accuracy. Flow Rate Range. Fluid Temperature. Fluid Viscosity. Connection Size. Flange Rating. Housing. Material. Blade.

Applicable Fluid. Accuracy. Flow Rate Range. Fluid Temperature. Fluid Viscosity. Connection Size. Flange Rating. Housing. Material. Blade. TOKICO TURINE METER GS-F211E- Overview Turbine meter has an excellent performance with its distinctive structure. Comparing with the flow meter using other method, it has compact and lighter design and

More information

( Single Case Construction )

( Single Case Construction ) OVL FLOWMETER Meter Size:,,,, ( Single ase onstruction ) Pocketless Design GENERL SPEIFITION GS.No.GBB--E GENERL The OVL flowmeter is a positive displacement type flowmeter comprising a pair of oval gear

More information

VORTEX FLOWMETER (DELTA FLOWPET)

VORTEX FLOWMETER (DELTA FLOWPET) VORTEX FOWMETER (DETA FOWPET) DATA SHEET FMR, M This instrument is a Karman vortex flowmeter capable of measuring the flow rate of liquid, gas, and vapor. The heavyduty detecting section made of stainless

More information

Turbine Meter TRZ 03 PRODUCT INFORMATION. Reliable Measurement of Gas

Turbine Meter TRZ 03 PRODUCT INFORMATION. Reliable Measurement of Gas Turbine Meter TRZ 0 PRODUCT INFORMATION Reliable Measurement of Gas TURBINE METER TRZ 0 Method of operation, Construction Method of operation The TRZ 0 turbine meter is a flow meter suitable for gas measurement

More information

Integral V-Cone Flowmeter VD series

Integral V-Cone Flowmeter VD series TRANSMITTER DIRECTLY MOUNTED! SIMPLE AND EASY INSTALLATION Integral V-Cone Flowmeter VD series OUTLINE VD series Integral V-Cone Flowmeter is a differential pressure type flowmeter. Unlikely to existing

More information

ST3000 Series 900 Smart Transmitter Differential Pressure Transmitters

ST3000 Series 900 Smart Transmitter Differential Pressure Transmitters No. SS2-STJ100-0100 (Rev.9) ST3000 Series 900 Smart Transmitter Differential Pressure Transmitters Model STD910/STD920/STD930/STD960/STD921/STD931/STD961 OVERVIEW The ST3000 Smart Transmitter is a microprocessor-based

More information

K Series SIGHT GLASS FOR CONVENIENT OBSERVATION OF LIQUID FLOW GENERAL

K Series SIGHT GLASS FOR CONVENIENT OBSERVATION OF LIQUID FLOW GENERAL FOR CONVENIENT OBSERVATION OF IQUID FOW K Series SIGHT GASS GENERA K series are sight glasses for observation of various liquids. Different types are available to meet applications and requirements. Cast

More information

MX Series COMPACT AND USER FRIENDLY. Metal Tube Type Variable Area Flowmeter OUTLINE STANDARD SPECIFICATION MODEL CODE MX-400, MX-71 MX-52E

MX Series COMPACT AND USER FRIENDLY. Metal Tube Type Variable Area Flowmeter OUTLINE STANDARD SPECIFICATION MODEL CODE MX-400, MX-71 MX-52E OMPT ND USER FRIENDLY MX Series Metal Tube Type Variable rea Flowmeter OUTLINE MX Series flowmeter is the metal tube type variable area flowmeter having the unified face-to-face dimension. The compact

More information

ULTRA OVAL METER SIZES:29, 60, 31, 32, 33 (Single-case Construction) Register Types A, B, and D

ULTRA OVAL METER SIZES:29, 60, 31, 32, 33 (Single-case Construction) Register Types A, B, and D UT OV METE SIZES:9, 60,,, (Singlecase Construction) egister Types, B, and GENE SPECIICTION GS.No. GENE Our workhorse P flowmeter series is redesigned in this UT OV with the most advanced multifunction

More information

405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test Data Book and Flow Handbook

405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test Data Book and Flow Handbook Reference Manual 405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test Book and Flow Handbook www.rosemount.com Reference Manual 405 and 1595 405 Compact Orifice Series and 1595 Conditioning

More information

CORIOLIS MASS FLOW METERS FOR GAS AND LIQUID MEASUREMENT. Michael Keilty (Presented by Hubbard Donald) Endress + Hauser Flowtec AG

CORIOLIS MASS FLOW METERS FOR GAS AND LIQUID MEASUREMENT. Michael Keilty (Presented by Hubbard Donald) Endress + Hauser Flowtec AG Introduction CORIOLIS MASS FLOW METERS FOR GAS AND LIQUID MEASUREMENT Michael Keilty (Presented by Hubbard Donald) Endress + Hauser Flowtec AG A mass flowmeter is a system that provides a measurement of

More information

405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test Data Book and Flow Handbook

405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test Data Book and Flow Handbook 405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test Book and Flow Handbook www.rosemount.com 405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test Book NOTICE Read

More information

Volumetric Flow Measurement

Volumetric Flow Measurement Volumetric Flow Measurement TVF Series Vortex Flow Meter Xi an Tosilon Automation Co., Ltd No.299, Daqing Rd, Lianhu District, Xi'an Shaanxi, China Tel: +86-29-8823 8550 info@tosilon.com; www.tosilon.com

More information

Electromagnetic Flowmeter

Electromagnetic Flowmeter Overview Flokal B.V. smart electromagnetic flow meter is hallmarked by its high performance and reliability that are based on successful, field-proven technology. It s being widely used in industries such

More information

Coriolis Mass Flowmeter. (MCM Series) 100% Customer Satisfaction MAXIFLO TM. Coriolis Mass Flowmeter Series MCM

Coriolis Mass Flowmeter. (MCM Series) 100% Customer Satisfaction MAXIFLO TM. Coriolis Mass Flowmeter Series MCM MAXIFO TM Features MaxiFlo Coriolis Mass Flowmeter series MCM is a mass flow meter that measures mass flow, density and temperature of liquids, slurries and gases. And it even measures oil content in water.

More information

SECTION 1 - WHAT IS A BTU METER? BTU's = Flow x ΔT Any ISTEC BTU Meter System consists of the following main components:

SECTION 1 - WHAT IS A BTU METER? BTU's = Flow x ΔT Any ISTEC BTU Meter System consists of the following main components: SECTION 1 - WHAT IS A BTU METER? ISTEC BTU Meters measure energy usage by multiplying flow rate and temperature difference. As the water (or other liquid) passes through these lines, the multi-wing turbine

More information

Pro-V Multivariable Flowmeter Model M23 Insertion Vortex

Pro-V Multivariable Flowmeter Model M23 Insertion Vortex Pro-V Multivariable Flowmeter Model M23 Insertion Vortex Pro-V TM Advantage: Volumetric or mass flow monitoring of most liquids, gases, and steam Multivariable meter delivers mass flow, temperature, pressure,

More information

PTF30 Series. Features. Ordering information. G 6 N N F8 (0 to 5 kgf/cm 2 ) PTF30

PTF30 Series. Features. Ordering information. G 6 N N F8 (0 to 5 kgf/cm 2 ) PTF30 eries Features Best pressure transmission solution for small and middle sized project such as indoor heating and air conditioning, water and sewer, or incinerator, etc. Improves noise resistance and minimize

More information

AM-1000 Series COMPACT FLOWMETER

AM-1000 Series COMPACT FLOWMETER METAL TUBE VARIABLE AREA FLOWMETER AM0 Series COMPACT FLOWMETER GENERAL AM0 series are most well accepted metal tube flowmeters which have been developed based on the long time experience of TOKYO KEISO

More information

405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test Data Book and Flow Handbook

405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test Data Book and Flow Handbook 405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test Book and Flow Handbook www.rosemount.com 405 and 1595 405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test

More information

Pro-V Multivariable Flowmeter Model M23 Insertion Vortex

Pro-V Multivariable Flowmeter Model M23 Insertion Vortex Pro-V Multivariable Flowmeter Model M23 Insertion Vortex Pro-V TM Advantage: Volumetric or mass flow monitoring of most liquids, gases, and steam Multivariable meter delivers mass flow, temperature, pressure,

More information

INTERNATIONAL OIML D 25 DOCUMENT. Vortex meters used in measuring systems for fluids ORGANISATION INTERNATIONALE INTERNATIONAL ORGANIZATION

INTERNATIONAL OIML D 25 DOCUMENT. Vortex meters used in measuring systems for fluids ORGANISATION INTERNATIONALE INTERNATIONAL ORGANIZATION INTERNATIONAL OIML D 25 DOCUMENT Edition 1996 (E) Vortex meters used in measuring systems for fluids Compteurs à vortex utilisés dans les ensembles de mesurage de fluides OIML D 25 Edition 1996 (E) ORGANISATION

More information

Installation guide 862 MIT / MIR

Installation guide 862 MIT / MIR Installation guide 862 MIT / MIR in combination with: 864 MTT or 863 MRT or (dual) spot element November 2005 Part no. 4416.232_Rev3 Enraf BV PO Box 812 2600 AV Delft Netherlands Tel. : +31 15 2701 100

More information

E6C-N. Ideal for Out-of-step Detection of Stepping Motors and Position Control of Rotors and Unloaders

E6C-N. Ideal for Out-of-step Detection of Stepping Motors and Position Control of Rotors and Unloaders Multi-turn High-precision Encoder Ideal for Out-of-step Detection of Stepping Motors and Position Control of Rotors and Unloaders Reset function for easy origin alignment when built-into equipment. Multi-turn

More information

ED 701 General Industry Pressure Transmitter

ED 701 General Industry Pressure Transmitter ED 701 General Industry Pressure Transmitter Standard industrial process connections Complete range of electrical connections 4... 20 ma and Voltage outputs Accuracy: 0.1%, 0.2% and 0.4% FS Quick response

More information

IBV Series Z Alloy Steel Inverted Bucket Vertical Steam Trap

IBV Series Z Alloy Steel Inverted Bucket Vertical Steam Trap Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

IBV Series C Carbon Steel Inverted Bucket Vertical Steam Trap

IBV Series C Carbon Steel Inverted Bucket Vertical Steam Trap Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

Pro-V Multivariable Flowmeter Model M22 In-line Vortex

Pro-V Multivariable Flowmeter Model M22 In-line Vortex Pro-V Multivariable Flowmeter Model M22 In-line Vortex Pro-V TM Advantage: Volumetric or mass flow monitoring of most liquids, gases, and steam Multivariable meter delivers mass flow, temperature, pressure,

More information

FLOW MEASUREMENT. INC 102 Fundamental of Instrumentation and Process Control 2/2560

FLOW MEASUREMENT. INC 102 Fundamental of Instrumentation and Process Control 2/2560 FLOW MEASUREMENT INC 102 Fundamental of Instrumentation and Process Control 2/2560 TABLE OF CONTENTS A. INTRODUCTION B. LOCAL FLOW MEASUREMENT B.1 Particle Image Velocimetry (PIV) B.2 Laser doppler anemometry

More information

Target Insertion Flowmeter

Target Insertion Flowmeter Principle of Operation Flow is measured in terms of dynamic force acting on a target (solid disk) in the flow stream. Hermetically sealed, bonded strain gages in a bridge circuit configuration mounted

More information

Cone differential pressure flow meter. Operating manual WIDE PLUS PRECISION INSTRUMENTS CO., LTD.

Cone differential pressure flow meter. Operating manual WIDE PLUS PRECISION INSTRUMENTS CO., LTD. Cone differential pressure flow meter Operating manual WIDE PLUS PRECISION INSTRUMENTS CO., LTD. INDEX Introduction 2 Principle Application The characteristics of flow meter Specification Technical features

More information

AM-1000 Series COMPACT FLOWMETER

AM-1000 Series COMPACT FLOWMETER METAL TUBE VARIABLE AREA FLOWMETER AM0 Series COMPACT FLOWMETER GENERAL AM0 series are most well accepted metal tube flowmeters which have been developed based on the long time experience of TOKYO KEISO

More information

Universal type Port size AS13 1F-M3. M3 x 0.5 M5 x 0.8 AS23 1F-01 AS23 1F-02 AS33 1F-02 AS33 1F-03 AS43 1F-04 R 1/8 R 1/4 R 1/4 R 3/8 R 1/2

Universal type Port size AS13 1F-M3. M3 x 0.5 M5 x 0.8 AS23 1F-01 AS23 1F-02 AS33 1F-02 AS33 1F-03 AS43 1F-04 R 1/8 R 1/4 R 1/4 R 3/8 R 1/2 Minimizes installation time and cost Reduces the mounting height and enables compact machinery design. Effective area is larger than the former model. Tube swivels 0 Universal type permits 0 piping swivel.

More information

E8EB-N0C2B E8EB-N0B2B

E8EB-N0C2B E8EB-N0B2B Slim Sensor CSM DS_E 1 Ideal for Workpiece Position and Original Checking The to 1 kpa model can be used for workpiece position checking. The to 1MPa model is ideal for original pressure checking. Degree

More information

TF-1000 Series MINI THERMAL MASS FLOWMETER PERFECT LINE-UP, BEST COST PERFORMANCE OUTLOOK FEATURES OPERATION PRINCIPLE PRODUCT LINE-UP

TF-1000 Series MINI THERMAL MASS FLOWMETER PERFECT LINE-UP, BEST COST PERFORMANCE OUTLOOK FEATURES OPERATION PRINCIPLE PRODUCT LINE-UP PERECT INE-UP, EST COST PERORMNCE T-000 Series MINI TERM MSS OWMETER OUTOOK T-000 MINI TERM MSS OWMETERS are designed and developed to offer the remote indication and control of gas flow process where

More information

Pressure. 1 Fitting PA R - N R2

Pressure. 1 Fitting PA R - N R2 INTERNAL STRUCTURE (R 1/4) 4 1 2 3 FEATURES High corrosion resistance and drip-proof construction port attachment made of Proven IP-65 grade gauge body (IP-65 in accordance with IEC) Standard product provides

More information

Fitting PS P - B - R2

Fitting PS P - B - R2 INTERNAL STRUCTURE PS86 (G 3/8) 2 3 FEATURES Solidstate pressure switch with no mechanical moving parts Isolated output via a photo-coupler Switching pressure adjustable and hysteresis band adjustable

More information

Pressure Measurement. Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level 2/27

Pressure Measurement. Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level 2/27 Overview Siemens AG 011 Function s are for measuring the liquid levels in wells, tanks, channels and dams. Diaphragm p Sensor U const. U + (brown) I EM I -1 (blue) 0, U B s are submersible sensors for

More information

Low Differential Pressure Gage

Low Differential Pressure Gage Low Differential Pressure Gage NEW Manostar Gage Panel installation compact type Low Differential Pressure Gage RoHS compliant Utility model registration No.2027772 Compact and lightweight type Even when

More information

SITRANS F flowmeters. SITRANS F US System information SITRANS F US Ultrasonic flowmeters 4/181

SITRANS F flowmeters. SITRANS F US System information SITRANS F US Ultrasonic flowmeters 4/181 Siemens AG 09 SITRANS F flowmeters System information Overview Siemens offers two types of ultrasonic flowmeters, in-line flowmeters and clamp-on flowmeters. This offers the end user the maximum flexibility

More information

Single point load cells

Single point load cells SP4M Single point load cells Special features Maximum capacities: kg 200 kg Aluminum High ratio of minimum verification Offcenter load compensation Shielded connection cable Explosion protection and other

More information

DIFFERENTIAL PRESSURE (FLOW) TRANSMITTER

DIFFERENTIAL PRESSURE (FLOW) TRANSMITTER DIFFERENTIAL PRESSURE (FLOW) TRANSMITTER DATA SHEET FKC...5 The FCX AIII differential pressure (flow) transmitter accurately measures differential pressure, liquid level, gauge pressure or flow rate and

More information

DOG-1/-3. Oscillation Flowmeter. for gases. Measuring ranges: m 3 /h air : 120 C. p max. : PN 40; t max

DOG-1/-3. Oscillation Flowmeter. for gases. Measuring ranges: m 3 /h air : 120 C. p max. : PN 40; t max Oscillation Flowmeter for gases measuring monitoring analysing DOG1/3 Measuring ranges: 0.2 20... 200 20000 m 3 /h air p max : PN 40; t max : 120 C Connection: flange DN 25... DN 400 Material: cast iron,

More information

ABB SpA COMEM Operating Unit Strada Regionale 11, Signolo Montebello Vicentino (VI) - ITALY

ABB SpA COMEM Operating Unit Strada Regionale 11, Signolo Montebello Vicentino (VI) - ITALY ABB SpA COMEM Operating Unit Strada Regionale 11, Signolo 22 36054 Montebello Vicentino (VI) - ITALY www.abb.com/transformercomponents The information contained in this document is for general information

More information

Differential Pressure Transmitters

Differential Pressure Transmitters No. SS2-00D-0100 AT9000 Advanced Transmitter Differential Pressure Transmitters OVERVIEW AT9000 Advanced Transmitter is a microprocessor-based smart transmitter that features high performance and excellent

More information

Solenoid valves Type EVUL

Solenoid valves Type EVUL Data sheet Solenoid valves EVUL EVUL solenoid valves are designed to fit into compact refrigeration systems. Available in servo operated versions they can be applied in liquid, suction, and hot gas lines.

More information

Turbine flowmeter and viscosity effects of liquid hydrocarbons

Turbine flowmeter and viscosity effects of liquid hydrocarbons Turbine flowmeter and viscosity effects of liquid hydrocarbons Valmir Ruiz, Marcos Tadeu Pereira,2, Nilson Massami Taira Institute for Technological Research IPT, 2 Universidade de São Paulo Avenida Prof.

More information

Electric Double Layer Capacitors Product Specification. To. : DATE : SPECIFICATION WRITTEN CHECKED APPROVED

Electric Double Layer Capacitors Product Specification. To. : DATE : SPECIFICATION WRITTEN CHECKED APPROVED To. : DATE : 200... SPECIFICATION PRODUCT MODEL : STARCAP : DCS series WRITTEN CHECKED APPROVED 1 Index Page No. ITEM etc. 1 Cover Page 2 Index 1. Scope 2. Part Number System 3 3. Product Model Name 4.

More information

variable flow dampers

variable flow dampers Constant-/ DAU, DAEU, DAVU Summary DAU - manual single flow unit DAEU - motorized twin flow unit DAVU - motorized variable flow unit Diameters Ø 0 Flow range 0 l/s ( m³/h) Pressure range Pa (over the unit)

More information

Flow Measurement. SITRANS F M System information SITRANS F M electromagnetic flowmeters. 4/22 Siemens FI

Flow Measurement. SITRANS F M System information SITRANS F M electromagnetic flowmeters. 4/22 Siemens FI Function All are based on Faraday s law of induction: U M = B v d k U M = Measured voltage induced in the medium perpendicular to the magnetic field and the flow direction. The voltage is tapped at two

More information

Pressure transmitters for industrial applications MBS 32 and MBS 33

Pressure transmitters for industrial applications MBS 32 and MBS 33 Data sheet Pressure transmitters for industrial applications MBS 32 and MBS 33 The standard pressure transmitters MBS 32 and MBS 33 are designed for use in almost all industrial applications, and offer

More information

CALYS 120 IS. ATEX documenting multifunction calibrator with high accuracy 0.006%

CALYS 120 IS. ATEX documenting multifunction calibrator with high accuracy 0.006% ATEX documenting multifunction calibrator with high accuracy 0.006% is the top instrument of our range of ATEX documenting multifunction calibrators. Description is the top instrument of our range of ATEX

More information

AT9000 Advanced Transmitter Differential Pressure Transmitters

AT9000 Advanced Transmitter Differential Pressure Transmitters No. SS2-GTX00D-0100 (Rev.8) AT9000 Advanced Transmitter Differential Pressure Transmitters OVERVIEW AT9000 Advanced Transmitter is a microprocessor-based smart transmitter that features high performance

More information

Application of Density Meters to Liquid Hydrocarbon Measurement

Application of Density Meters to Liquid Hydrocarbon Measurement 02/2018 Application of Density Meters to Liquid Hydrocarbon Measurement Written by Dean Minehart, Micro Motion, Inc. www.emerson.com/micromotion 1 Introduction The American Petroleum Institute (API) Manual

More information

TF-1000 Series MINI THERMAL MASS FLOWMETER PERFECT LINE-UP, BEST COST PERFORMANCE OUTLOOK FEATURES OPERATION PRINCIPLE PRODUCT LINE-UP

TF-1000 Series MINI THERMAL MASS FLOWMETER PERFECT LINE-UP, BEST COST PERFORMANCE OUTLOOK FEATURES OPERATION PRINCIPLE PRODUCT LINE-UP PERFET INE-UP, EST OST PERFORMANE TF-000 Series MINI TERMA MASS FOWMETER OUTOOK TF-000 MINI TERMA MASS FOWMETERS are designed and developed to offer the remote indication and control of gas flow process

More information

FKC... 5 DIFFERENTIAL PRESSURE (FLOW) TRANSMITTER FEATURES SPECIFICATIONS. Functional specifications

FKC... 5 DIFFERENTIAL PRESSURE (FLOW) TRANSMITTER FEATURES SPECIFICATIONS. Functional specifications FKC... 5 DIFFERENTIAL PRESSURE (FLOW) TRANSMITTER The FCX AIII differential pressure (flow) transmitter accurately measures differential pressure, liquid level, gauge pressure or flow rate and transmits

More information

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm DMP P Industrial Pressure Transmitter Process Connections With Flush Welded Stainless Steel accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 % FSO Nominal pressure from 0... 00 mbar up

More information

14:1400 (0206) KRAL Volumeter - OMG

14:1400 (0206) KRAL Volumeter - OMG 14:1400 (0206) KRAL Volumeter - OMG OMG - Universal OMG The flowmeter for a wide range of applications Operating Conditions and Materials Flow Range: 0.1 to 7,500 l/min Max. Pressure: 250 bar Temperature

More information

Model Selection 1. Process Valves. Air. Vacuum

Model Selection 1. Process Valves. Air. Vacuum Process Valves Model Selection For product specifications such as maximum operating pressure differentials and operating temperature ranges, refer to the relevent pages of each product. Air One-touch fittings

More information

SAMPLE SHEET. Supply of PF Process Calculation Spreadsheet (Excel Forma)

SAMPLE SHEET. Supply of PF Process Calculation Spreadsheet (Excel Forma) PROJECT NO. PO. 4500098732 / 10 / 01.01.2018 Supply of PF Process Calculation Spreadsheet (Excel Forma) DOCUMENT TITLE Small Bore Orifice Sizing Calculation For Gas Services as per ASME-MFC-14M-2001 DATE

More information

Check-Q-meter. Table of contents. Features. Functions. RE 27551/ /10 Replaces: Type FD

Check-Q-meter. Table of contents. Features. Functions. RE 27551/ /10 Replaces: Type FD Check-Q-meter RE /0.0 /0 Replaces: 09.9 Type FD Nominal size... Series ax. Operating pressure 0 bar ax. Flow 0 l/min K9/ Table of contents Contents Page Features Functions Ordering details Symbols Functional

More information

Industrial Air Diffuser Type DLD for Heating and Cooling

Industrial Air Diffuser Type DLD for Heating and Cooling LTG Incorporated Industrial Air Diffuser Type DLD for Heating and Cooling LTG Incorporated Corporate Drive, Suite E Spartanburg, SC 20 PO Box 288, Spartanburg, SC 20 USA Tel: 8--0 Fax: 8-- e-mail: info@ltg-inc.net

More information

MR medium rating busbar

MR medium rating busbar technical information General features MR is fully compliant with S EN 0-, specifically, the rated current of the Zucchini busbar trunking systems is always rated at the average ambient temperature of

More information

Exam #2: Fluid Kinematics and Conservation Laws April 13, 2016, 7:00 p.m. 8:40 p.m. in CE 118

Exam #2: Fluid Kinematics and Conservation Laws April 13, 2016, 7:00 p.m. 8:40 p.m. in CE 118 CVEN 311-501 (Socolofsky) Fluid Dynamics Exam #2: Fluid Kinematics and Conservation Laws April 13, 2016, 7:00 p.m. 8:40 p.m. in CE 118 Name: : UIN: : Instructions: Fill in your name and UIN in the space

More information

Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level

Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level Overview Function s are for measuring the liquid levels in wells, tanks, channels and dams. Sensor Diaphragm p U const. U +2 (brown) I EM I - (blue) 0, U B s are submersible sensors for hydrostatic level

More information

Operating Instructions for Digital Manometer. Model: MAN-SD

Operating Instructions for Digital Manometer. Model: MAN-SD Operating Instructions for Digital Manometer Model: MAN-SD 1. Contents 1. Contents...2 2. Note...3 3. Instrument Inspection...3 4. Regulation Use...4 5. Operating Principle...4 6. Mechanical Connection...5

More information

tekcor TKC Multivariable Coriolis Flow Sensors

tekcor TKC Multivariable Coriolis Flow Sensors Sensing the pulse of industry Technical Data Sheet & General Specifications tekcor TKC Multivariable Coriolis Flow Sensors The tekcor TKC Series principle was initiated by tekflo sensors engineers, who

More information

High-efficiency Circulator Pump. Rio-Eco N / Rio-Eco Z N. Type Series Booklet

High-efficiency Circulator Pump. Rio-Eco N / Rio-Eco Z N. Type Series Booklet High-efficiency Circulator Pump Rio-Eco N / Rio-Eco Z N Type Series Booklet Legal information/copyright Type Series Booklet Rio-Eco N / Rio-Eco Z N KSB Aktiengesellschaft All rights reserved. The contents

More information

ELECTRONIC FLOWMETERS FOR THERMAL ENERGY MEASUREMENT. By Dr. Crainic Monica Sabina

ELECTRONIC FLOWMETERS FOR THERMAL ENERGY MEASUREMENT. By Dr. Crainic Monica Sabina ELECTRONIC FLOWMETERS FOR THERMAL ENERGY MEASUREMENT By Dr. Crainic Monica Sabina Luxten Lighting Company AEM Branch Office Gas and Water Meters Research Department 26 Calea Buziaşului300693 Timişoara

More information

FLUID MECHANICS D203 SAE SOLUTIONS TUTORIAL 2 APPLICATIONS OF BERNOULLI SELF ASSESSMENT EXERCISE 1

FLUID MECHANICS D203 SAE SOLUTIONS TUTORIAL 2 APPLICATIONS OF BERNOULLI SELF ASSESSMENT EXERCISE 1 FLUID MECHANICS D203 SAE SOLUTIONS TUTORIAL 2 APPLICATIONS OF BERNOULLI SELF ASSESSMENT EXERCISE 1 1. A pipe 100 mm bore diameter carries oil of density 900 kg/m3 at a rate of 4 kg/s. The pipe reduces

More information

ABB MEASUREMENT & ANALYTICS DATA SHEET. PGC5000 Temperature programmed gas chromatograph

ABB MEASUREMENT & ANALYTICS DATA SHEET. PGC5000 Temperature programmed gas chromatograph ABB MEASUREMENT & ANALYTICS DATA SHEET PGC5000 Temperature programmed gas chromatograph 2 P G C 5 0 0 0 T E M P E R AT U R E P R O G R A M M E D D S/ P G C 5 0 0 0 T P - E N Measurement & Analytics The

More information

ISOCON-6. 24V AC or DC POWERED ISOLATING SIGNAL CONVERTER

ISOCON-6. 24V AC or DC POWERED ISOLATING SIGNAL CONVERTER ISOCON-6 24V AC or DC POWERED ISOLATING SIGNAL CONVERTER Whilst every effort has been taken to ensure the accuracy of this document, we accept no responsibility for damage, injury, loss or expense resulting

More information

Drive electronics pq12

Drive electronics pq12 Drive electronics pq12 Amplifier module with constant current controller for proportional valves Control of one solenoid Easy mounting directly on bearing rails acc. to EN 50022 Standard voltage and current

More information

EXPERIMENT NO. 4 CALIBRATION OF AN ORIFICE PLATE FLOWMETER MECHANICAL ENGINEERING DEPARTMENT KING SAUD UNIVERSITY RIYADH

EXPERIMENT NO. 4 CALIBRATION OF AN ORIFICE PLATE FLOWMETER MECHANICAL ENGINEERING DEPARTMENT KING SAUD UNIVERSITY RIYADH EXPERIMENT NO. 4 CALIBRATION OF AN ORIFICE PLATE FLOWMETER MECHANICAL ENGINEERING DEPARTMENT KING SAUD UNIVERSITY RIYADH Submitted By: ABDULLAH IBN ABDULRAHMAN ID: 13456789 GROUP A EXPERIMENT PERFORMED

More information

PAA-ANALYZERS PRINCIPLE OF OPERATION

PAA-ANALYZERS PRINCIPLE OF OPERATION PAA-ANALYZERS PRINCIPLE OF OPERATION The PAA process analyzer comprises a control unit and an analyzing section which includes the reaction chamber and measuring cell, reagent pumps and associated valves

More information

DS 200P. Electronic Pressure Switch. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

DS 200P. Electronic Pressure Switch. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm accuracy according to IEC 600: standard: 0. % FSO option: 0. % FSO Nominal pressure from 0... 00 mbar up to 0... 0 bar

More information

Custody Transfer Measurement and Calibration Round Robin Testing for Natural Gas with Coriolis Meters

Custody Transfer Measurement and Calibration Round Robin Testing for Natural Gas with Coriolis Meters Custody Transfer Measurement and Calibration Round Robin Testing for Natural Gas with Coriolis Meters 1 Agenda Coriolis Meter Principle of Operation AGA Report No. 11 Conversion of Mass to Gas Standard

More information

LECTURE 6- ENERGY LOSSES IN HYDRAULIC SYSTEMS SELF EVALUATION QUESTIONS AND ANSWERS

LECTURE 6- ENERGY LOSSES IN HYDRAULIC SYSTEMS SELF EVALUATION QUESTIONS AND ANSWERS LECTURE 6- ENERGY LOSSES IN HYDRAULIC SYSTEMS SELF EVALUATION QUESTIONS AND ANSWERS 1. What is the head loss ( in units of bars) across a 30mm wide open gate valve when oil ( SG=0.9) flow through at a

More information

Hydraulic Design Of Polyethylene Pipes

Hydraulic Design Of Polyethylene Pipes Hydraulic Design Of Polyethylene Pipes Waters & Farr polyethylene pipes offer a hydraulically smooth bore that provides excellent flow characteristics. Other advantages of Waters & Farr polyethylene pipes,

More information

Chemical Engineering 3P04 Process Control Tutorial # 1 Learning goals

Chemical Engineering 3P04 Process Control Tutorial # 1 Learning goals Chemical Engineering 3P04 Process Control Tutorial # 1 Learning goals 1. Sensor Principles with the flow sensor example 2. The typical manipulated variable: flow through a conduit Sensors: We need them

More information

Vacuum capacitors overview Capacitor selection guides

Vacuum capacitors overview Capacitor selection guides JENNINGS TECHNOLOGY Vacuum capacitors overview Capacitor selection guides Capacitors by type Capacitor type Vacuum variable Capacity max. (pf) Test voltage / Hz Model no. series Page number 7.,, 1 CVDD-

More information

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm DMP Pi Precision Pressure Transmitter pressure ports and process connections with flush welded stainless steel diaphragm accuracy according to IEC 600: 0, % FSO Nominal pressure from 0... 00 mbar up to

More information

General Specifications

General Specifications General Specifications Model EJB110 Differential Pressure Transmitter [Style: S2] The model EJB110 Differential Pressure Transmitter can be used to measure liquid, gas, or steam flow,

More information

VK2 volume flow controller Overview

VK2 volume flow controller Overview New option with sound attenuator Maintenance-free VK2 volume flow controller that operates without an auxiliary power supply, for ventilation and air conditioning systems. Adjustable on site. Outstanding

More information

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm DMP Pi Precision Pressure Transmitter pressure ports and process connections with flush welded stainless steel diaphragm accuracy according to IEC 600: 0, % FSO Nominal pressure from 0... 00 mbar up to

More information

Field IT 50T Series Transmitters

Field IT 50T Series Transmitters Data Sheet SS/G/A_ Field IT 0T Series Transmitters gauge/absolute pressure transmitter Ranges: -00 to 0000kPa - to 00bar -. to 6000psi Base accuracy : 0.% (BFSL) Chemical Vapour Deposition (CVD) technology

More information

Odor Removal Filter Series AMF

Odor Removal Filter Series AMF Odor Removal Filter Series AMF Series AMF Odor Removal Filter efficiently removes odor in compressed air with an activated carbon element. The unit is designed for use in food processing, pharmaceutical,

More information

ALASTAIR MCLACHLAN Applications Cameron

ALASTAIR MCLACHLAN Applications Cameron ALASTAIR MCLACHLAN Applications Cameron Have worked in the oil and gas flow measurement industry for 27 years primarily in custody transfer measurement using ultrasonic meters. Joined Cameron Caldon Ultrasonics

More information

Variable Displacement Plug-In Motor A6VE. Series 6, for open and closed circuits Axial tapered piston, bent axis design

Variable Displacement Plug-In Motor A6VE. Series 6, for open and closed circuits Axial tapered piston, bent axis design rueninghaus Hydromatik Series 6, for open and closed circuits xial tapered piston, bent axis design Size 28...20 Nom. pressure up to 400 bar Peak pressure up to 40 bar RE 9606/0.97 RE 9606/0.97 replaces

More information

Solar Flat Plate Thermal Collector

Solar Flat Plate Thermal Collector Solar Flat Plate Thermal Collector INTRODUCTION: Solar heater is one of the simplest and basic technologies in the solar energy field. Collector is the heart of any solar heating system. It absorbs and

More information

Ultrasonic Gas Flow Meter

Ultrasonic Gas Flow Meter P r o d u c t i n f o r m at i o n FLOWSIC600 Ultrasonic Gas Flow Meter For custody transfer and process applications Analyzers and Process Instrumentation FLOWSIC600 For Custody Transfer and Process Applications

More information

Chapter 4 DYNAMICS OF FLUID FLOW

Chapter 4 DYNAMICS OF FLUID FLOW Faculty Of Engineering at Shobra nd Year Civil - 016 Chapter 4 DYNAMICS OF FLUID FLOW 4-1 Types of Energy 4- Euler s Equation 4-3 Bernoulli s Equation 4-4 Total Energy Line (TEL) and Hydraulic Grade Line

More information

An Essential Requirement in CV Based Industrial Appliances.

An Essential Requirement in CV Based Industrial Appliances. Measurement of Flow P M V Subbarao Professor Mechanical Engineering Department An Essential Requirement in CV Based Industrial Appliances. Mathematics of Flow Rate The Scalar Product of two vectors, namely

More information

FACULTY OF CHEMICAL & ENERGY ENGINEERING FLUID MECHANICS LABORATORY TITLE OF EXPERIMENT: MINOR LOSSES IN PIPE (E4)

FACULTY OF CHEMICAL & ENERGY ENGINEERING FLUID MECHANICS LABORATORY TITLE OF EXPERIMENT: MINOR LOSSES IN PIPE (E4) FACULTY OF CHEMICAL & ENERGY ENGINEERING FLUID MECHANICS LABORATORY TITLE OF EXPERIMENT: MINOR LOSSES IN PIPE (E4) 1 1.0 Objectives The objective of this experiment is to calculate loss coefficient (K

More information

CALYS 80P. Field pressure calibrator with high accuracy 0.01%

CALYS 80P. Field pressure calibrator with high accuracy 0.01% Field pressure calibrator with high accuracy 0.01% CALYS 80P is a field pressure calibrator within CALYS range with high accuracy of 0.01%. Description CALYS 80P is a field pressure calibrator within CALYS

More information

Direct-operated 2/2-way solenoid valves Type EV210B

Direct-operated 2/2-way solenoid valves Type EV210B Data sheet Direct-operated 2/2-way solenoid valves Type EV20B EV20B covers a wide range of direct-operated 2/2-way solenoid valves for universal use. EV20B is a very robust valve program with high performance

More information

COMPACT FLOWMETER TO COVER ALL POSSIBLE APPLICATIONS. METAL TUBE AM-1000 Series GENERAL FEATURES TG-F962-0E APR.,2000 AM-1000 COMPACT FLOWMETER

COMPACT FLOWMETER TO COVER ALL POSSIBLE APPLICATIONS. METAL TUBE AM-1000 Series GENERAL FEATURES TG-F962-0E APR.,2000 AM-1000 COMPACT FLOWMETER AM0 TO COVER ALL POSSIBLE APPLICATIONS METAL TUBE AM0 Series GENERAL AM0 series are most well accepted metal tube flowmeters which have been developed based on the long time experience of TOKYO KEISO in

More information