ULTRA OVAL Meter Sizes:39, 41, 45, 50, 52, 53 w/unfactored Pulse Generator (NPG60A)

Size: px
Start display at page:

Download "ULTRA OVAL Meter Sizes:39, 41, 45, 50, 52, 53 w/unfactored Pulse Generator (NPG60A)"

Transcription

1 ULTRA OVAL Meter Sizes:9, 4, 45, 50, 5, 5 w/unfactored Pulse Generator (NPG60A) GENERAL SPECIFICATION GS.No.GBU0--E GENERAL ULTRA OVAL MODEL 9, 4, and45 provides extensive capability as a highly dependable OVAL flowmeter to be used for various application in process where accurate flow measurement of low flow rate is required. FEATURES. Accurate (Linearity) to ±0.5% or better. Well suited for small flow measurements.. Pocketless design of measuring chamber construction makes the flowmeter ideal for fine chemicals, foods, pharmaceuticals, cosmetics and etc., furthermore, simplifies maintenance and inspection work.. Flowrate information is transmitted by the pulse generator in the form of a noncontact pulse signal compatible with highly sensitive and reliable remote instrumentation. 4. Absence of any mechanical transmission requires no loss in torque and ensures long service life. 5. Flow totalizing and instantaneous flowrate indication are monitored in a LCD counter independently mounted. Meter : 9, 4, 45, 50 Meter : 5, 5 GENERAL SPECIFICATIONS Basic Meter Item Meter Size Nominal Size Flange Rating Group Group Flow range Operating Temp. Range Linearity Repeatability Meter Body Rear Lid Material Rotor Bearings Shaft Flow direction Finish Description mm 0mm 5mm JIS 0K RF, ANSI 50 RF, JPI 50RF JIS6, 0, 0K RF, ANSI 00 RF, JPI 00 RF, DIN0, 6, 0, 5 See flow rang table (P) 0 ~ +0 C ±0.5% ±0.5% or ±0.5% ±0.5% ±0.05% or ±0.0% SCS4 or SCS6 SUS6 or SUS6L Special Carbon SUS6 or SUS6L Special Carbon Special Carbon or Ceramics SUS6 or SUS6L Right Left (St d) Left Right Top Bottom Bottom To Not painted : Special Flange Ratings and Max. Operating pressure : MPa Flange Code JIS 0K RF ANSI 50 RF JIS 0 K RF JIS 0K RF ANSI 00 RF.8 () at 0 C.50 (5.) at 0 C (0) at 0 C.94 (0) at 0 C.94 (0) at 0 C OVAL Corporation Head Office: Tokyo; Tel Fax Beijing Office: Tel., Fax Tel Overseas Branch Offices: Seoul. Singapore. Taipei

2 Pulse Generator Item Meter Size 9, 4, 45, 50, 5, 5 Generator NPG60A Output signal Pulse Pulse Pulse Power supply Cable Transmission longth Wiring mode Ambient temperature Ambient humidity Construction Current Type Pulse with Description Unscaled : 0/=4/0mADC, See range opload resistance (P) ms (Fixed) Open Type Unscaled : Max. 0VDC, allowable current : 50mADC collector Pulse with ms (Fixed) Voltage Material for the housing Coting color Type Pulse width Unscaled : 0/=Max.VDC/Power voltage Min.VDC ms (Fixed) ~4VDC Current consumption Max.0mADC See range opload resistance (P) Cable w/outernal shield (CVVS.5mm ) finished O.D. 8.5~mm km wires system Currene pulse wires system Open collector or voltage pulse 0~+70 C (explesion-proof : 0~+55 C) 5~00%RH, Condensation not allowedπ Explosion-proof construction : ExdIIBT4X Water-proof construction : JIS C090 Splash proof type (IP65equivalend) Non-explosion-proof construction Alminum Alloy Baked Painting, Color : Muncell.5BG5/6 (Cover) Muncell.5G8/ (Body) : For wiring of explosion-proof model, ensure tp use the heat-resisting cable(more than 70 C)and pressure tight packing attached. NOMINZAL METER FACTOR Meter P/r Nominal Meter Factor ml/p ml/p ml/p ml/p ml/p ml/p METER ERROR and PRESSURE LOSS Meter Error (%) Meter Error (%) Meter : 9, 4, Lub. Oil (0mPa. s) Kerosene (.mpa. s) Gasoline (0.4mPa. s) Lub. Oil Kerosene Gasoline 0% 5% 50% 75% 00% Flow rate (m /h) Meter : 50, 5, 5 Fuel Oil (mpa. s) Kerosene (0.mPa. s) Water (mpa. s) Gasoline (0.4mPa. s) Fuel Oil Water Gasoline % 5% 50% 75% 00% Flow rate(m /h) 00% Flow rate indicates the Max. Flowrate for each viscosity Pressure Loss (KPa) Pressure Loss (KPa) FLOW RANGE Flow rate for water shall be selected from the following specification for temperature and viscosity. Temperature range Nax. 0 C 0 ~ 80 C 80 ~ 0 C Linearity : ±0.5%, Operating Temp. Range: 0 ~ +0 C Meter Meter Linearity : ±0.5% (Option) Operating Temp. Range: 0 ~ +0 C Meter Meter Viscosity range 0.8 ~.0mPa. s 0. ~ 0.8mPa. s Less than 0.mPa. s Note : () Only Model 45 is available up to 000mPa. s. Note : () Consult Fectory for High viscosity liquid more than 000mPa. s. Unit in L/h Viscosity less than 0. ~ 0.8 ~ ~ 5 ~ Range 0.mPa.s 0.8mPa.s mpa.s 5mPa.s 00mPa.s Unit in m /h Viscosity less than 0. ~ 0.8 ~ ~ 5 ~ Range 0.mPa.s 0.8mPa.s mpa.s 5mPa.s 000mPa.s Unit in L/h Viscosity less than 0. ~ 0.8 ~ ~ 5 ~ Range 0.mPa.s 0.8mPa.s mpa.s 5mPa.s 00mPa.s Unit in m /h Viscosity less than 0. ~ 0.8 ~ ~ 5 ~ Range 0.mPa.s 0.8mPa.s mpa.s 5mPa.s 000mPa.s

3 SYSTEM OF RECEIVING INSTRUMENTS Totalizer (EL0) Analog Signal 40mADC 5VDC (Option) Open Collector 40mADC 5VDC F/I Converter (SU, SU5) 00mVDC 000ADC ULTRAOVAL Meter 50 w/npg60a Unfactored Pulse Analog Signal Pulse Signal (Contact/Voltage) 40mADC 050mADC 5VDC Scaled Pulse Converter/Compensator or Pulse Output EL084 Unscaled Pulse The diagram shows an example to be applied. According to user s request, any other instrumentation can be arranged. With regard to the detailed information for each instrument, consult the factory. Pulse Signal Scaled Pulse (St d) Open Collector or Unscaled Pulse CONNECTING DIAGRAM [] Current Pulse SUP. COM. 4 A 00 R + + (~4VDC 0%) ms RX0mA 750 Load Registance ( ) Zone of Load Registance Action Zone RX4mA Power Voltage (VDC) [] Open Collector Pulse E ( 0VDC) R (Allowable current : Max.50mA) 4 SUP. SIG. COM. Max.50mA + + (~4VDC 0%) ms Lo Level (<VDC) Hi Level (Supply Voltage) [] Voltage Pulse 4 SUP. SIG. COM. Power Voltage + (~4VDC 0%) + ms Max.VDC More than (Power Voltage VDC)

4 OUT DIMENSIONS (Unit in mm) Meter : 9, 4, 45, 50 L B 0 C D Conduit Connection G/ E Meter Flange Rating L(Face to Face) B(Full Length) C D E Approx.Mass. JIS 0K RF 9 ANSI/JPI 50 RF 4 JIS 0K RF kg 45 JIS 0K RF ANSI/JPI 00 RF JIS 0K RF 00 ANSI/JPI 50 RF 98 8kg 50 JIS 0K RF JIS 0K RF 08 kg ANSI/JPI 00 RF 04 Meter : 5, 5 L 06 B 79 C D Conduit Connection G/ E Meter Flange Rating L(Face to Face) B(Full Length) C D E Approx.Mass. JIS 0K RF ANSI/JPI 50 RF 00 9kg 5 JIS 0K RF JIS 0K RF kg ANSI/JPI 00 RF 07 JIS 0K RF ANSI/JPI 50 RF 00 0kg 5 JIS 0K RF JIS 0K RF kg ANSI/JPI 00 RF 07 4

5 PRODUCT CODE EXPLANATION Item Code No. Type L U S 9 4 Meter C Materials E Z Fange rating Bearing type Generator Construction generator 7 0 Type of output signal Description ULTRA OVAL ( 0~+0 C) Nominal Size : 0mm Nominal Size : 0mm Nominal Size : 0mm Nominal Size : 0mm Nominal Size : 5mm Nominal Size : 5mm SUS6 Rotor + SCS4 Body (Meter l 9 is used only special carbon.) SUS6L Rotor + SCS6 Body [Special] Other than above JIS 0K RF, ANSI / JPI 50 RF JIS 6~0K RF, ANSI / JPI 00 RF, DIN 0~5 Carbon Bearing (OB44) Ceramic Bearing (OB96) Nonpolymeric Ceramics (OB96) Nonpolymeric Carbon (OB44) NPG60A Non-explosionproof (NPG60A) Flameproof (NPG60AEP) TIIS Flameproof (NPG60AEP) NEPSI Unscaled Pulse (4/0mA Current Pulse), Wire system Unscaled Pulse (Open collector), Wire system Unscaled Pulse (Voltage Pulse), Wire system Notes:. Flange face provides RF only, FF is not supplied.. Meter s 4 and 45 use the same body material SUS6 or 6L for rotors. Meter 9 uses special carbon rotors only. 5

6 STRAINER It is necessary to install a strainer directly before the flow meter or as close as possible on the flow input side, so that solid particles mixed in the fluid do not enter the flow meter and causes problems. Model number SR0 C 0 JIS 0K RF 80 SR0 C 0 SR0 C 0 Nominal Flange rating L (mm) H (mm) Body material Net material Net mesh Applicable meter model JIS 0K RF mm ANS/JPI 50 RF 78 SCS4A SUS JIS 0K RF ANS/JPI 00 RF 87 SR0 C (E) 0 JIS 0K RF 80 SR0 C SCS4A SUS6 (E) 0 0mm ANS/JPI 50 RF SR0 C (SCS6A) (SUS6L) (E) 0 JIS 0K RF 84 SR0 C (E) 0 JIS 0K RF 0 65 SR08 C SCS4A SUS6 5 (E) 0 5mm ANS/JPI 50 RF 60 SR08 C 09 (SCS6A) (SUS6L) 5 (E) 0 JIS 0K RF 4 6

7 POINTS OF CAUTION These flowmeters used to measure minute flow rate are precisely adjusted in the factory, so it is necessary to take special care when unpacking, installing in the piping and testing. Never let foreign materials enter into the measuring chamber. Flush the piping well enough before installation. It is essential that you always avoid violently spinning the rotor by flushing air or an excessive flow rate in a short period of time. Only use Oval's strainer dedicatedly designed for these flowmeters. PLEASE SUPPLY THE FOLLOWING INFORMATION WHEN YOU INQUIRE.. Model L. Fluid to be measured Name Viscosity mpa s Specific gravity. Flow rate (L/h) Maximum Normal Minimum 4. Fluid temperature ( C) Maximum Normal Minimum 5. Ambient temperature ( C) Maximum Normal Minimum 6. Pressure (MPa) Maximum Normal Minimum 7. Flow direction Right Left, Bottom Top 8. Flange connection Nominal diameter mm, Flange rating 9. Required accuracy (Linearity) ± % 0. Explosion-proof construction Required class Not required. Accessories Strainer, Air eliminator, Companion flange. Quantity Including accessories. Receiving device Type, manufacturer, model, specifications (input, output, power supply, etc.) 4. Distance between the flow meter and the receiving device m 7

8 The specification as of May, 006 is stated in this GS Sheet. Specifications and design are subject to change without notice. Sales Representative:

( Single Case Construction )

( Single Case Construction ) OVL FLOWMETER Meter Size:,,,, ( Single ase onstruction ) Pocketless Design GENERL SPEIFITION GS.No.GBB--E GENERL The OVL flowmeter is a positive displacement type flowmeter comprising a pair of oval gear

More information

DELTA FLOWMETER FOR GAS SERVICE (INSERTION TYPE) MODEL VF SERIES

DELTA FLOWMETER FOR GAS SERVICE (INSERTION TYPE) MODEL VF SERIES DETA FOWMETER FOR GAS SERVICE (INSERTION TYPE) MODE VF SERIES GENERA SPECIFICATION GS. No. GBD0-0-E GENERA In the thermistor type Delta meter, a probe inserted in the pipeline detects the representative

More information

MODEL: CR002, CR003, CR004. ADC12 Display shield. Liquid (Density range: 0.3 to 2.0g/mL) Operating temperature range

MODEL: CR002, CR003, CR004. ADC12 Display shield. Liquid (Density range: 0.3 to 2.0g/mL) Operating temperature range Liquid Inexpensive Microflow Coriolis Flowmeter CoriMate Ⅱ MODEL: CR002, CR003, CR004 GENERAL Based on the knowledge and experience on Coriolis technologies OVAL has gained over many years, the Corimate

More information

MODEL : TX Series (Nom. sizes 15mm to 400mm)

MODEL : TX Series (Nom. sizes 15mm to 400mm) iquid High performance and wide viscosity range EX TURBINE MODE : TX Series (Nom. sizes 15mm to 4mm) GENERA EX TURBINE is an industrial turbine meter for consistent and accurate liquid flow measurement.

More information

Applicable Fluid. Accuracy. Flow Rate Range. Fluid Temperature. Fluid Viscosity. Connection Size. Flange Rating. Housing. Material. Blade.

Applicable Fluid. Accuracy. Flow Rate Range. Fluid Temperature. Fluid Viscosity. Connection Size. Flange Rating. Housing. Material. Blade. TOKICO TURINE METER GS-F211E- Overview Turbine meter has an excellent performance with its distinctive structure. Comparing with the flow meter using other method, it has compact and lighter design and

More information

MX Series COMPACT AND USER FRIENDLY. Metal Tube Type Variable Area Flowmeter OUTLINE STANDARD SPECIFICATION MODEL CODE MX-400, MX-71 MX-52E

MX Series COMPACT AND USER FRIENDLY. Metal Tube Type Variable Area Flowmeter OUTLINE STANDARD SPECIFICATION MODEL CODE MX-400, MX-71 MX-52E OMPT ND USER FRIENDLY MX Series Metal Tube Type Variable rea Flowmeter OUTLINE MX Series flowmeter is the metal tube type variable area flowmeter having the unified face-to-face dimension. The compact

More information

Coriolis Mass Flowmeter. (MCM Series) 100% Customer Satisfaction MAXIFLO TM. Coriolis Mass Flowmeter Series MCM

Coriolis Mass Flowmeter. (MCM Series) 100% Customer Satisfaction MAXIFLO TM. Coriolis Mass Flowmeter Series MCM MAXIFO TM Features MaxiFlo Coriolis Mass Flowmeter series MCM is a mass flow meter that measures mass flow, density and temperature of liquids, slurries and gases. And it even measures oil content in water.

More information

Electromagnetic Flowmeter

Electromagnetic Flowmeter Overview Flokal B.V. smart electromagnetic flow meter is hallmarked by its high performance and reliability that are based on successful, field-proven technology. It s being widely used in industries such

More information

Integral V-Cone Flowmeter VD series

Integral V-Cone Flowmeter VD series TRANSMITTER DIRECTLY MOUNTED! SIMPLE AND EASY INSTALLATION Integral V-Cone Flowmeter VD series OUTLINE VD series Integral V-Cone Flowmeter is a differential pressure type flowmeter. Unlikely to existing

More information

K Series SIGHT GLASS FOR CONVENIENT OBSERVATION OF LIQUID FLOW GENERAL

K Series SIGHT GLASS FOR CONVENIENT OBSERVATION OF LIQUID FLOW GENERAL FOR CONVENIENT OBSERVATION OF IQUID FOW K Series SIGHT GASS GENERA K series are sight glasses for observation of various liquids. Different types are available to meet applications and requirements. Cast

More information

Turbine Meter TRZ 03 PRODUCT INFORMATION. Reliable Measurement of Gas

Turbine Meter TRZ 03 PRODUCT INFORMATION. Reliable Measurement of Gas Turbine Meter TRZ 0 PRODUCT INFORMATION Reliable Measurement of Gas TURBINE METER TRZ 0 Method of operation, Construction Method of operation The TRZ 0 turbine meter is a flow meter suitable for gas measurement

More information

VORTEX FLOWMETER (DELTA FLOWPET)

VORTEX FLOWMETER (DELTA FLOWPET) VORTEX FOWMETER (DETA FOWPET) DATA SHEET FMR, M This instrument is a Karman vortex flowmeter capable of measuring the flow rate of liquid, gas, and vapor. The heavyduty detecting section made of stainless

More information

Operating Instructions for Digital Manometer. Model: MAN-SD

Operating Instructions for Digital Manometer. Model: MAN-SD Operating Instructions for Digital Manometer Model: MAN-SD 1. Contents 1. Contents...2 2. Note...3 3. Instrument Inspection...3 4. Regulation Use...4 5. Operating Principle...4 6. Mechanical Connection...5

More information

ST3000 Series 900 Smart Transmitter Differential Pressure Transmitters

ST3000 Series 900 Smart Transmitter Differential Pressure Transmitters No. SS2-STJ100-0100 (Rev.9) ST3000 Series 900 Smart Transmitter Differential Pressure Transmitters Model STD910/STD920/STD930/STD960/STD921/STD931/STD961 OVERVIEW The ST3000 Smart Transmitter is a microprocessor-based

More information

Target Insertion Flowmeter

Target Insertion Flowmeter Principle of Operation Flow is measured in terms of dynamic force acting on a target (solid disk) in the flow stream. Hermetically sealed, bonded strain gages in a bridge circuit configuration mounted

More information

PTF30 Series. Features. Ordering information. G 6 N N F8 (0 to 5 kgf/cm 2 ) PTF30

PTF30 Series. Features. Ordering information. G 6 N N F8 (0 to 5 kgf/cm 2 ) PTF30 eries Features Best pressure transmission solution for small and middle sized project such as indoor heating and air conditioning, water and sewer, or incinerator, etc. Improves noise resistance and minimize

More information

Cone differential pressure flow meter. Operating manual WIDE PLUS PRECISION INSTRUMENTS CO., LTD.

Cone differential pressure flow meter. Operating manual WIDE PLUS PRECISION INSTRUMENTS CO., LTD. Cone differential pressure flow meter Operating manual WIDE PLUS PRECISION INSTRUMENTS CO., LTD. INDEX Introduction 2 Principle Application The characteristics of flow meter Specification Technical features

More information

14:1400 (0206) KRAL Volumeter - OMG

14:1400 (0206) KRAL Volumeter - OMG 14:1400 (0206) KRAL Volumeter - OMG OMG - Universal OMG The flowmeter for a wide range of applications Operating Conditions and Materials Flow Range: 0.1 to 7,500 l/min Max. Pressure: 250 bar Temperature

More information

Pro-V Multivariable Flowmeter Model M23 Insertion Vortex

Pro-V Multivariable Flowmeter Model M23 Insertion Vortex Pro-V Multivariable Flowmeter Model M23 Insertion Vortex Pro-V TM Advantage: Volumetric or mass flow monitoring of most liquids, gases, and steam Multivariable meter delivers mass flow, temperature, pressure,

More information

AM-1000 Series COMPACT FLOWMETER

AM-1000 Series COMPACT FLOWMETER METAL TUBE VARIABLE AREA FLOWMETER AM0 Series COMPACT FLOWMETER GENERAL AM0 series are most well accepted metal tube flowmeters which have been developed based on the long time experience of TOKYO KEISO

More information

AM-1000 Series COMPACT FLOWMETER

AM-1000 Series COMPACT FLOWMETER METAL TUBE VARIABLE AREA FLOWMETER AM0 Series COMPACT FLOWMETER GENERAL AM0 series are most well accepted metal tube flowmeters which have been developed based on the long time experience of TOKYO KEISO

More information

SECTION 1 - WHAT IS A BTU METER? BTU's = Flow x ΔT Any ISTEC BTU Meter System consists of the following main components:

SECTION 1 - WHAT IS A BTU METER? BTU's = Flow x ΔT Any ISTEC BTU Meter System consists of the following main components: SECTION 1 - WHAT IS A BTU METER? ISTEC BTU Meters measure energy usage by multiplying flow rate and temperature difference. As the water (or other liquid) passes through these lines, the multi-wing turbine

More information

ULTRA OVAL METER SIZES:29, 60, 31, 32, 33 (Single-case Construction) Register Types A, B, and D

ULTRA OVAL METER SIZES:29, 60, 31, 32, 33 (Single-case Construction) Register Types A, B, and D UT OV METE SIZES:9, 60,,, (Singlecase Construction) egister Types, B, and GENE SPECIICTION GS.No. GENE Our workhorse P flowmeter series is redesigned in this UT OV with the most advanced multifunction

More information

Proximity Sensor Ideal for High Temperatures and Cleaning Processes. Applicable to 120 C

Proximity Sensor Ideal for High Temperatures and Cleaning Processes. Applicable to 120 C ASH & ALAIN INDIA PVT LTD S-00, F.I.E.E., Okhla Industrial Area, Phase-ii, New Delhi-000(India) Tel : 0-797575 Fax : 0-79757 E-mail : sales@ashalain.com Proximity Ideal for High Temperatures and Cleaning

More information

ABB SpA COMEM Operating Unit Strada Regionale 11, Signolo Montebello Vicentino (VI) - ITALY

ABB SpA COMEM Operating Unit Strada Regionale 11, Signolo Montebello Vicentino (VI) - ITALY ABB SpA COMEM Operating Unit Strada Regionale 11, Signolo 22 36054 Montebello Vicentino (VI) - ITALY www.abb.com/transformercomponents The information contained in this document is for general information

More information

PG-200/PG-208 PRESSURE GAUGES P G G P P

PG-200/PG-208 PRESSURE GAUGES P G G P P Digital 3 1/2 digits monitor Set button for switch output HI or LO (PG-200) (PG-208) Digital 3 1/2 digits Power switch LO setting VR for switch output LO HI setting VR for switch output HI SPAN adjustment

More information

E6C-N. Ideal for Out-of-step Detection of Stepping Motors and Position Control of Rotors and Unloaders

E6C-N. Ideal for Out-of-step Detection of Stepping Motors and Position Control of Rotors and Unloaders Multi-turn High-precision Encoder Ideal for Out-of-step Detection of Stepping Motors and Position Control of Rotors and Unloaders Reset function for easy origin alignment when built-into equipment. Multi-turn

More information

Fitting PS P - B - R2

Fitting PS P - B - R2 INTERNAL STRUCTURE PS86 (G 3/8) 2 3 FEATURES Solidstate pressure switch with no mechanical moving parts Isolated output via a photo-coupler Switching pressure adjustable and hysteresis band adjustable

More information

Pro-V Multivariable Flowmeter Model M23 Insertion Vortex

Pro-V Multivariable Flowmeter Model M23 Insertion Vortex Pro-V Multivariable Flowmeter Model M23 Insertion Vortex Pro-V TM Advantage: Volumetric or mass flow monitoring of most liquids, gases, and steam Multivariable meter delivers mass flow, temperature, pressure,

More information

Pilot operated 2 port solenoid valve (general purpose valve) Standard specifications NC (normally closed) type C C. 2 /s) Starting

Pilot operated 2 port solenoid valve (general purpose valve) Standard specifications NC (normally closed) type C C. 2 /s) Starting 21/22 Series (general purpose valve) 21/22 Series NC (normally closed) type, NO (normally open) type Port size: Rc1 1/4 to Rc2, 32 to 50 flange iaphragm structure JIS symbol 21: Common specifications Item

More information

473-SHX Dew Point Mirror

473-SHX Dew Point Mirror Humidity and Temperature Reference Hygrometer For Temperature up to 125 C Precise and stable chilled mirror dew point mirror technology High temperature optical components High temperature sample fan Cable

More information

DRS 61: Incremental encoders, number of lines and zero pulse width freely programmable DRS 60: Incremental Encoders with Zero-Pulse-Teach

DRS 61: Incremental encoders, number of lines and zero pulse width freely programmable DRS 60: Incremental Encoders with Zero-Pulse-Teach NEW DRS : Incremental encoders, number of lines and zero pulse width freely programmable DRS : s with Zero-Pulse-Teach Further highlights of this generation of encoders: Simple zero-pulse-teach by pressing

More information

ED 701 General Industry Pressure Transmitter

ED 701 General Industry Pressure Transmitter ED 701 General Industry Pressure Transmitter Standard industrial process connections Complete range of electrical connections 4... 20 ma and Voltage outputs Accuracy: 0.1%, 0.2% and 0.4% FS Quick response

More information

ELECTRONIC FLOWMETERS FOR THERMAL ENERGY MEASUREMENT. By Dr. Crainic Monica Sabina

ELECTRONIC FLOWMETERS FOR THERMAL ENERGY MEASUREMENT. By Dr. Crainic Monica Sabina ELECTRONIC FLOWMETERS FOR THERMAL ENERGY MEASUREMENT By Dr. Crainic Monica Sabina Luxten Lighting Company AEM Branch Office Gas and Water Meters Research Department 26 Calea Buziaşului300693 Timişoara

More information

NOVALYNX CORPORATION MODEL 110-WS-16BP BAROMETRIC PRESSURE SENSOR INSTRUCTION MANUAL

NOVALYNX CORPORATION MODEL 110-WS-16BP BAROMETRIC PRESSURE SENSOR INSTRUCTION MANUAL NOVALYNX CORPORATION MODEL 110-WS-16BP BAROMETRIC PRESSURE SENSOR INSTRUCTION MANUAL REVISION DATE: OCT 2005 Receiving and Unpacking Carefully unpack all components and compare to the packing list. Notify

More information

technical bulletin Installation Instructions: Wall-Mount Dewpoint Probe ( )

technical bulletin Installation Instructions: Wall-Mount Dewpoint Probe ( ) Installation Instructions: Wall-Mount Dewpoint Probe (809-2011) The HMW90 Wall-Mount Dewpoint Probe (P/N 809-2011) HMW90 measures dewpoint for indoor applications such as anti-sweat heater control and

More information

Dimensional drawing face mount flange radial. R = bending radius min. 40 mm. Dimensional drawing face mount flange axial

Dimensional drawing face mount flange radial. R = bending radius min. 40 mm. Dimensional drawing face mount flange axial Incremental Encoder DRS/DRS, face mount flange up to 8,2 Dimensional drawing face mount flange radial Incremental Encoder Connector or cable outlet Protection class up to IP s TTL and HTL Zero-Pulse-Teach

More information

INTERNATIONAL OIML D 25 DOCUMENT. Vortex meters used in measuring systems for fluids ORGANISATION INTERNATIONALE INTERNATIONAL ORGANIZATION

INTERNATIONAL OIML D 25 DOCUMENT. Vortex meters used in measuring systems for fluids ORGANISATION INTERNATIONALE INTERNATIONAL ORGANIZATION INTERNATIONAL OIML D 25 DOCUMENT Edition 1996 (E) Vortex meters used in measuring systems for fluids Compteurs à vortex utilisés dans les ensembles de mesurage de fluides OIML D 25 Edition 1996 (E) ORGANISATION

More information

w w w. i n t e l l i g e n t a c t u a t o r. d e

w w w. i n t e l l i g e n t a c t u a t o r. d e GB SCARA ROBOT w w w. i n t e l l i g e n t a c t u a t o r. d e 0.2 400 IX-NNW70(7040) 0.2 400 IX-NNW80(8040) (inverse) T(U)NN TNN UNN IX-T(U)NN301 IX-T(U)NN31 IX-H(I)NN0 (inverse) HNN IX-H(I)NN60 H(I)NN

More information

Industrial Pressure Transmitter

Industrial Pressure Transmitter ECT 87 Industrial Pressure Transmitter Swiss based Trafag is a leading international supplier of high quality sensors and monitoring instruments for measurement of and temperature. The economical transmitter

More information

ISOCON-6. 24V AC or DC POWERED ISOLATING SIGNAL CONVERTER

ISOCON-6. 24V AC or DC POWERED ISOLATING SIGNAL CONVERTER ISOCON-6 24V AC or DC POWERED ISOLATING SIGNAL CONVERTER Whilst every effort has been taken to ensure the accuracy of this document, we accept no responsibility for damage, injury, loss or expense resulting

More information

473 Dew Point Hygrometer

473 Dew Point Hygrometer High Performance Chilled Mirror Hygrometer With Cable Mounted Measuring Heads Highly precise chilled mirror dew point technology Cable mounted dew point and temperature measurement Aspirated and direct

More information

Field IT 50T Series Transmitters

Field IT 50T Series Transmitters Data Sheet SS/G/A_ Field IT 0T Series Transmitters gauge/absolute pressure transmitter Ranges: -00 to 0000kPa - to 00bar -. to 6000psi Base accuracy : 0.% (BFSL) Chemical Vapour Deposition (CVD) technology

More information

Pressure Measurement. Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level 2/27

Pressure Measurement. Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level 2/27 Overview Siemens AG 011 Function s are for measuring the liquid levels in wells, tanks, channels and dams. Diaphragm p Sensor U const. U + (brown) I EM I -1 (blue) 0, U B s are submersible sensors for

More information

General Specifications

General Specifications General Specifications Model EJB110 Differential Pressure Transmitter [Style: S2] The model EJB110 Differential Pressure Transmitter can be used to measure liquid, gas, or steam flow,

More information

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm DMP Pi Precision Pressure Transmitter pressure ports and process connections with flush welded stainless steel diaphragm accuracy according to IEC 600: 0, % FSO Nominal pressure from 0... 00 mbar up to

More information

Pro-V Multivariable Flowmeter Model M22 In-line Vortex

Pro-V Multivariable Flowmeter Model M22 In-line Vortex Pro-V Multivariable Flowmeter Model M22 In-line Vortex Pro-V TM Advantage: Volumetric or mass flow monitoring of most liquids, gases, and steam Multivariable meter delivers mass flow, temperature, pressure,

More information

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm DMP Pi Precision Pressure Transmitter pressure ports and process connections with flush welded stainless steel diaphragm accuracy according to IEC 600: 0, % FSO Nominal pressure from 0... 00 mbar up to

More information

Pressure Transmitter ED 701

Pressure Transmitter ED 701 Pressure Transmitter ED 701 Hygienic and industrial process connections Zero setting function Accuracy < 0.1% FS Quick response time < 25 ms High long-term stability Excellent repeatability Active compensation

More information

THM80X Series Feature Application. Temperature & Humidity / Flow Measuring Specialist

THM80X Series  Feature Application. Temperature & Humidity / Flow Measuring Specialist THM80X Series Feature Application IP67 protection degree, rugged aluminum case, fit in variety harsh environment Capable of temperature compensation Linear adjustment temperature & humidity by computer,

More information

Pressure. 1 Fitting PA R - N R2

Pressure. 1 Fitting PA R - N R2 INTERNAL STRUCTURE (R 1/4) 4 1 2 3 FEATURES High corrosion resistance and drip-proof construction port attachment made of Proven IP-65 grade gauge body (IP-65 in accordance with IEC) Standard product provides

More information

Operating instructions Magnetic-inductive flow sensor SM6004 SM7004 SM / / 2014

Operating instructions Magnetic-inductive flow sensor SM6004 SM7004 SM / / 2014 Operating instructions Magnetic-inductive flow sensor SM6004 SM7004 SM8004 80003223 / 00 05 / 2014 Contents 1 Preliminary note...3 1.1 Symbols used...3 2 Safety instructions...4 3 Functions and features...5

More information

Reference CL W - C01 - TS SPECIFICATIONS 1/ Scope of Application These specifications apply to CL-963-1W-C01-TS. 2. Part code.

Reference CL W - C01 - TS SPECIFICATIONS 1/ Scope of Application These specifications apply to CL-963-1W-C01-TS. 2. Part code. SPECIFICATIONS 1/10 1. Scope of Application These specifications apply to 2. Part code CL - 963-1W - C01 - TS Series Number of dice 1:1dice Lighting color Resin color C01:Color C,No.1 Shipping mode Non-coded:

More information

VK2 volume flow controller Overview

VK2 volume flow controller Overview New option with sound attenuator Maintenance-free VK2 volume flow controller that operates without an auxiliary power supply, for ventilation and air conditioning systems. Adjustable on site. Outstanding

More information

v = m / s Thermal Flow Sensors TA with thin-film sensor element Probes Probe Guides Measuring Tubes

v = m / s Thermal Flow Sensors TA with thin-film sensor element Probes Probe Guides Measuring Tubes Thermal Flow Sensors TA with thin-film sensor element Probes Probe Guides Measuring Tubes Examples of Application Flow measurements also in hazardous locations X zone 0 or zone 1 in clean rooms in air

More information

Capacitor Technology and Manufacturing Expertise

Capacitor Technology and Manufacturing Expertise Capacitors Capacitor Technology and Manufacturing Expertise With more than 25 years of experience in manufacturing single layer capacitors made with EIA Class I, II and III ceramic dielectric materials,

More information

Innovation in. Motionless Mixers

Innovation in. Motionless Mixers Innovation in Motionless Mixers Ross Motionless Mixers PIONEERING TECHNOLOGY. INCOMPARABLE QUALITY. WORLDWIDE LEADERSHIP. Serving all the process industries in virtually every industrialized country around

More information

AE / AER Series. AER Series

AE / AER Series. AER Series AE / AER Series Characteristic Highlights True helical gear design Precision helical gearing increases tooth to tooth contact ratio by over % vs spur gearing. The helix angle produces smooth and quiet

More information

Field Pro Operation and Installation Manual

Field Pro Operation and Installation Manual Field Pro Operation and Installation Manual Xtreme Research Corporation SkyScan Division P.O. Box 336, Port Richey, FL 34673-0336 1-800-732-0665 Table of Contents 1. Installation 3 2. Operation 5 3. Care

More information

Industrial Pressure Transmitter

Industrial Pressure Transmitter ECT 87 Industrial Pressure Transmitter Swiss based Trafag is a leading international supplier of high quality sensors and monitoring instruments for measurement of and temperature. The economical transmitter

More information

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm DMP P Industrial Pressure Transmitter Process Connections With Flush Welded Stainless Steel accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 % FSO Nominal pressure from 0... 00 mbar up

More information

Volumetric Flow Measurement

Volumetric Flow Measurement Volumetric Flow Measurement TVF Series Vortex Flow Meter Xi an Tosilon Automation Co., Ltd No.299, Daqing Rd, Lianhu District, Xi'an Shaanxi, China Tel: +86-29-8823 8550 info@tosilon.com; www.tosilon.com

More information

IBV Series Z Alloy Steel Inverted Bucket Vertical Steam Trap

IBV Series Z Alloy Steel Inverted Bucket Vertical Steam Trap Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

The FLUX F 430 with mechanical seal

The FLUX F 430 with mechanical seal The FLUX F 0 with mechanical seal Flexible coupling between motor and pump The pump must be used with many varying liquids, consequently the smallest residual left within the pump is unacceptable. You

More information

AIR PREPARATION. ELECTRONICALLY CONTROLLED PRESSURE REGULATING VALVE (PROPORTIONAL PRESSURE REGULATING VALVE) SERIES control

AIR PREPARATION. ELECTRONICALLY CONTROLLED PRESSURE REGULATING VALVE (PROPORTIONAL PRESSURE REGULATING VALVE) SERIES control AIR PREPARATION ELECTRONICALLY CONTROLLED PRESSRE REGLATING ALE (PROPORTIONAL PRESSRE REGLATING ALE) SERIES control Description Abb. Port size Recommended Type Data Sheet No. flow (l/min)* airfit tecno

More information

CORIOLIS MASS FLOW METERS FOR GAS AND LIQUID MEASUREMENT. Michael Keilty (Presented by Hubbard Donald) Endress + Hauser Flowtec AG

CORIOLIS MASS FLOW METERS FOR GAS AND LIQUID MEASUREMENT. Michael Keilty (Presented by Hubbard Donald) Endress + Hauser Flowtec AG Introduction CORIOLIS MASS FLOW METERS FOR GAS AND LIQUID MEASUREMENT Michael Keilty (Presented by Hubbard Donald) Endress + Hauser Flowtec AG A mass flowmeter is a system that provides a measurement of

More information

Variable Displacement Plug-In Motor A6VE. Series 6, for open and closed circuits Axial tapered piston, bent axis design

Variable Displacement Plug-In Motor A6VE. Series 6, for open and closed circuits Axial tapered piston, bent axis design rueninghaus Hydromatik Series 6, for open and closed circuits xial tapered piston, bent axis design Size 28...20 Nom. pressure up to 400 bar Peak pressure up to 40 bar RE 9606/0.97 RE 9606/0.97 replaces

More information

IBV Series C Carbon Steel Inverted Bucket Vertical Steam Trap

IBV Series C Carbon Steel Inverted Bucket Vertical Steam Trap Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

473 Dew Point Hygrometer

473 Dew Point Hygrometer gh Performance Chilled Hygrometer With Cable Mounted Measuring Heads ghly precise chilled mirror dew point technology Cable mounted dew point and temperature measurement Aspirated and direct insertion

More information

NR ROTARY RING TABLE: FLEXIBLE IN EVERY RESPECT

NR ROTARY RING TABLE: FLEXIBLE IN EVERY RESPECT NR FREELY PROGRAMMABLE ROTARY TABLES NR ROTARY RING TABLE All NR rings allow customer-specific drive motors to be connected NR ROTARY RING TABLE: FLEXIBLE IN EVERY RESPECT WHEN IT S GOT TO BE EXACT We

More information

High-efficiency Circulator Pump. Rio-Eco N / Rio-Eco Z N. Type Series Booklet

High-efficiency Circulator Pump. Rio-Eco N / Rio-Eco Z N. Type Series Booklet High-efficiency Circulator Pump Rio-Eco N / Rio-Eco Z N Type Series Booklet Legal information/copyright Type Series Booklet Rio-Eco N / Rio-Eco Z N KSB Aktiengesellschaft All rights reserved. The contents

More information

- compressed air plants (refrigerating/adsorption dryers) - granulate dryers - medical gases - non-corrosive gases, e. g. nitrogen

- compressed air plants (refrigerating/adsorption dryers) - granulate dryers - medical gases - non-corrosive gases, e. g. nitrogen INSTRUCTION MANUAL FA 510 The CS dew point sensor FA 510 with 3-wire technology 4 20 ma and RS 485 output enables a reliable and long-term stable monitoring of the dew point in industrial applications

More information

Cooler-Bypass Thermostat Valve, Size 10

Cooler-Bypass Thermostat Valve, Size 10 Cooler-Bypass Thermostat Valve, Size Q max = l/min, p max = bar Temperature-controlled, integral relief function Description These direct acting bypass thermostat valves are size, temperature controlled,

More information

Configurations: Dimension (mm) A (max) Item IRS IRS

Configurations: Dimension (mm) A (max) Item IRS IRS Configurations: FEATURES Magnetically shielded construction. Compact and thin. Put the electrode with ferrite core directly, a small surface area allow a high mounting. Shielding Drum Choke for good in

More information

Odor Removal Filter Series AMF

Odor Removal Filter Series AMF Odor Removal Filter Series AMF Series AMF Odor Removal Filter efficiently removes odor in compressed air with an activated carbon element. The unit is designed for use in food processing, pharmaceutical,

More information

M2 SERIES THERMOSTATS 0 F to 240 F, Narrow Differential, Hermetically Sealed ½

M2 SERIES THERMOSTATS 0 F to 240 F, Narrow Differential, Hermetically Sealed ½ M2 SERIES THERMOSTATS 0 F to 240 F, Narrow Differential, Hermetically Sealed ½ Introduction The Klixon M2 thermostat is constructed with a snap acting bimetal disc that serves as the actuating element.

More information

E 094 E 103 E 143. Tank top mounting Connection up to G1 Nominal flow rate up to 135 l/min e

E 094 E 103 E 143. Tank top mounting Connection up to G1 Nominal flow rate up to 135 l/min e R e t u r n F i l t e rs E 094 E 103 E 143 Tank top mounting Connection up to G1 Nominal flow rate up to 135 l/min 20.30-5e D e s c r i p t i o n Application In the return line circuits of hydraulic systems.

More information

HRN/HRN-C Series Hydraulic Vane Rotary Actuators

HRN/HRN-C Series Hydraulic Vane Rotary Actuators HRN/ Hydraulic Vane Rotary Actuators Vane Actuators Tork-Mor HRN Contents Features... 2 Ordering Information... Engineering Data / Specifications... Dimensions... Features... 1 Ordering Information...12

More information

Rotary modules.

Rotary modules. Rotary modules www.comoso.com www.comoso.com Rotary modules ROTARY MODULES Series Size Page Rotary modules RM swivel unit 156 RM 08 160 RM 10 162 RM 12 164 RM 15 168 RM 21 172 RM rotor 176 RM 50 180 RM

More information

Digital display Pressure range ON/OFF output Linear output Model No Positive pressure 0 to 98 kpa (0 to 1 kgf/cm 2 ) NPN open collector o 1 to o5

Digital display Pressure range ON/OFF output Linear output Model No Positive pressure 0 to 98 kpa (0 to 1 kgf/cm 2 ) NPN open collector o 1 to o5 Pressure Sensor E8CC with Built-in Microcomputer and Digital Display and New E8CB General-purpose Model Withstands a of 490 kpa (5 kgf/cm 2 ) and highly reliable. Incorporates a two-turn adjuster ensuring

More information

DOG-1/-3. Oscillation Flowmeter. for gases. Measuring ranges: m 3 /h air : 120 C. p max. : PN 40; t max

DOG-1/-3. Oscillation Flowmeter. for gases. Measuring ranges: m 3 /h air : 120 C. p max. : PN 40; t max Oscillation Flowmeter for gases measuring monitoring analysing DOG1/3 Measuring ranges: 0.2 20... 200 20000 m 3 /h air p max : PN 40; t max : 120 C Connection: flange DN 25... DN 400 Material: cast iron,

More information

Peltier Application Note

Peltier Application Note Peltier Application Note Early 19th century scientists, Thomas Seebeck and Jean Peltier, first discovered the phenomena that are the basis for today s thermoelectric industry. Seebeck found that if you

More information

(NE) Low Ohmic Value Ultra Precision Resistors

(NE) Low Ohmic Value Ultra Precision Resistors Version: March 1, 2017 Electronics Tech. (NE) Low Ohmic Value Ultra Precision Resistors Web: www.direct-token.com Email: rfq@direct-token.com Direct Electronics Industry Co., Ltd. China: 12F, Zhong Xing

More information

v = 00,20 m/s Thermal Flow Sensors TA with thin-film sensor element Probes Probe guides Measuring tubes

v = 00,20 m/s Thermal Flow Sensors TA with thin-film sensor element Probes Probe guides Measuring tubes with thin-film sensor element Probes Probe guides Measuring tubes Examples of Application Flow measurements also in hazardous locations Ex zone 0 or zone 1 in clean rooms in air conditioning and ventilating

More information

PECIFICATIONS Model TC03 Page 3 1. Scope This specification applies to the ceramic type trimmer capacitor using ceramic as a dielectric.

PECIFICATIONS Model TC03 Page 3 1. Scope This specification applies to the ceramic type trimmer capacitor using ceramic as a dielectric. PECIFICATIONS Model TC3 Page 3 1. Scope This specification applies to the ceramic type trimmer capacitor using ceramic as a dielectric. 2. Main characteristics Table 1 Part No. TC3Z5H169B TC3Z1H169B TC3R1H169B

More information

E8EB-N0C2B E8EB-N0B2B

E8EB-N0C2B E8EB-N0B2B Slim Sensor CSM DS_E 1 Ideal for Workpiece Position and Original Checking The to 1 kpa model can be used for workpiece position checking. The to 1MPa model is ideal for original pressure checking. Degree

More information

LEVEL CONTROLS. Selection Guide. Capacitance Calculations and Data For Selecting Robertshaw Level Control Instruments and Sensing Probes

LEVEL CONTROLS. Selection Guide. Capacitance Calculations and Data For Selecting Robertshaw Level Control Instruments and Sensing Probes LEVEL CONTROLS Selection Guide Capacitance Calculations and Data For Selecting Robertshaw Level Control Instruments and Sensing Probes Capacitance Probe Calculations The following data is compiled to assist

More information

Request Ensure that this Instruction Manual is delivered to the end users and the maintenance manager.

Request Ensure that this Instruction Manual is delivered to the end users and the maintenance manager. Request Ensure that this Instruction Manual is delivered to the end users and the maintenance manager. 1 -A - Introduction - Thank for your purchasing MITSUBISHI ELECTRIC MELPRO TM D Series Digital Protection

More information

SUZHOU YOHUA OPTO-ELECTRONICS TECHNOLOGY LTD PULSE CURRENT. LUMINOUS COLOR RANKS FORWARD VOLTAGE Reverse INTENSITY Part No.

SUZHOU YOHUA OPTO-ELECTRONICS TECHNOLOGY LTD PULSE CURRENT. LUMINOUS COLOR RANKS FORWARD VOLTAGE Reverse INTENSITY Part No. SUZHOU OPTO-ELECTRONICS TECHNOLOGY LTD Part no. Emitting color Material TOP5050UTW-E-3 White INGaN Picture Absolute Maximum Ratings at (TA=25 ) Part No. REVERSE VOLTAGE (

More information

Pressure transmitters for industrial applications MBS 32 and MBS 33

Pressure transmitters for industrial applications MBS 32 and MBS 33 Data sheet Pressure transmitters for industrial applications MBS 32 and MBS 33 The standard pressure transmitters MBS 32 and MBS 33 are designed for use in almost all industrial applications, and offer

More information

Check-Q-meter. Table of contents. Features. Functions. RE 27551/ /10 Replaces: Type FD

Check-Q-meter. Table of contents. Features. Functions. RE 27551/ /10 Replaces: Type FD Check-Q-meter RE /0.0 /0 Replaces: 09.9 Type FD Nominal size... Series ax. Operating pressure 0 bar ax. Flow 0 l/min K9/ Table of contents Contents Page Features Functions Ordering details Symbols Functional

More information

Linear actuator Econom 2. Our intelligent model: Econom 2. Econom 2

Linear actuator Econom 2. Our intelligent model: Econom 2. Econom 2 Linear actuator Econom 2 Our intelligent model: Econom 2 Econom 2 Linear actuators Econom 2 Description Applications Facts The users of the Econom 2 come from many different industries: From architects

More information

AT9000 Advanced Transmitter Differential Pressure Transmitters

AT9000 Advanced Transmitter Differential Pressure Transmitters No. SS2-GTX00D-0100 (Rev.8) AT9000 Advanced Transmitter Differential Pressure Transmitters OVERVIEW AT9000 Advanced Transmitter is a microprocessor-based smart transmitter that features high performance

More information

COMPACT FLOWMETER TO COVER ALL POSSIBLE APPLICATIONS. METAL TUBE AM-1000 Series GENERAL FEATURES TG-F962-0E APR.,2000 AM-1000 COMPACT FLOWMETER

COMPACT FLOWMETER TO COVER ALL POSSIBLE APPLICATIONS. METAL TUBE AM-1000 Series GENERAL FEATURES TG-F962-0E APR.,2000 AM-1000 COMPACT FLOWMETER AM0 TO COVER ALL POSSIBLE APPLICATIONS METAL TUBE AM0 Series GENERAL AM0 series are most well accepted metal tube flowmeters which have been developed based on the long time experience of TOKYO KEISO in

More information

Technical Data Sheet Silicon Planar PIN Photodiode

Technical Data Sheet Silicon Planar PIN Photodiode Technical Data Sheet Silicon Planar PIN Photodiode Features Daylight filter High sensitivity Low capacitance Short switching time Wide temperature range Small package Pb free The product itself will remain

More information

Full Metal Variable Area Flow Meter and Counter

Full Metal Variable Area Flow Meter and Counter Full Metal Variable rea Flow Meter and Counter for horizontal and vertical mounting measuring monitoring analysing Special versions up to 600 bar Measuring range: 10-100...00-000 L/h water 0.3-3.0...-0

More information

Pressure Display Controller

Pressure Display Controller MODEL DW Display Controller Low The Model DW pressure controller accurately monitors and controls very low pressures. It combines in one enclosure a low pressure transducer, a digital display and two alarms

More information

Industrial Air Diffuser Type DLD for Heating and Cooling

Industrial Air Diffuser Type DLD for Heating and Cooling LTG Incorporated Industrial Air Diffuser Type DLD for Heating and Cooling LTG Incorporated Corporate Drive, Suite E Spartanburg, SC 20 PO Box 288, Spartanburg, SC 20 USA Tel: 8--0 Fax: 8-- e-mail: info@ltg-inc.net

More information

Assembly and Maintenance manual according to regulation DIN 82079

Assembly and Maintenance manual according to regulation DIN 82079 Assembly and Maintenance manual according to regulation DIN 82079 ESORB Version 4.16 Part 1 Information to the manufacturer Giebel FilTec GmbH Carl-Zeiss-Str. 5 DE-74626 Bretzfeld-Schwabbach Tel. +49 (0)

More information

Power Dissipation Pd 120 mw Forward Current I F 30 ma Peak Forward Current *1 I FP 100 ma 佰鴻工業股份有限公司

Power Dissipation Pd 120 mw Forward Current I F 30 ma Peak Forward Current *1 I FP 100 ma 佰鴻工業股份有限公司 DATA SHEET DEVICE NUMBER: (For:2mA) SHEET 1 2 3 4 5 6 7 8 CONTENTS DATE 26.1.16 1. 1. 1. 1. 1. 1. 1. 1. Original Released 台北縣板橋市和平路 19 號 3 樓 3F., No. 19, Ho Ping Road, Pan Chiao City, 張 Taipei, Taiwan,

More information