1 PROJECT NO. PO / 10 / Supply of PF Process Calculation Spreadsheet (Excel Forma) DOCUMENT TITLE Small Bore Orifice Sizing Calculation For Gas Services as per ASME-MFC-14M-2001 DATE REV. REASON FOR REVISION PREP. CHKD. APPD. APPD. DOC. NO. CEPL-PC-001-CA-009 PAGE 1 OF 7 REV. 0
2 DOC. NO. CEPL-PC-001-CA-009 REV. 0 PROJECT NO. PO / 10 / PAGE NO. 2 of 7 BASIS Calculation Objective Calculation Basis Calculation Methodology Assumptions Software used Conclusions References Attachments
3 DOC. NO. PROJECT NO. CEPL-PC-001-CA-009 REV. 0 PO / 10 / PAGE NO. 3 of 7 SCHEMATIC: q m P 1, T 1 P 2 The purpose of this workbook is to calculate the gas flowrate from a small-bore orifice meter using the equations defined in ASME MFC-14M The equations are only valid under the following conditions Corner Taps: 0.1 < β < 0.8 and 12 mm < D < 40 mm Flange Taps: 0.15 < β < 0.7 and 25 mm < D < 40 mm D < 40 mm d > 6 mm NRe > 1000 A β of between 0.3 and 0.7 is practical; below this, the pressure drop is too large for economical operation, and above this, the pressure drop is not large enough for an accurate reading. SCHEMATIC: ORIFICE TAG NO. LINE NO. P&ID NO. DESCRIPTION T 50 oc Operating temperature P 1 10 kg/cm2g Upstream pressure P 2 5 kg/cm2g Downstream pressure ϒ P C bara Ratio of specific heat, C P /C V Critical pressure T C -10 oc Critical temperature P r 0.03 Reduced pressure T r 1.23 Reduced temperature F K 0.98 Correction factor κ Isentropic exponent Flow is sub-critical. Q μ M Z D Tap type 1 MMSCFD Gas flow rate 0.01 cp Gas viscosity 29 kg/kmol Gas molecular weight 1 Gas compressibility factor 36 mm Pipe ID Corner
4 DOC. NO. PROJECT NO. CEPL-PC-001-CA-009 PO / 10 / REV. 0 PAGE NO. 4 of 7 CALCULATION BASIS / EQUATIONS: Please refer attachment 1. T NTP P NTP ρ kg/m 3 NTP Density at NTP conditions T STP P STP Gas viscosity, Pa.s 50.0 Temperature, o C 9.8 Upstream pressure, barg P, Differential pressure measured across tappings, kpa Pipe Inside diameter, mm 0 o C atm ρ STP kg/m 3 RESULTS: Flow rate, kg/s Flow rate, m 3 /s Gas density, kg/m Downstream pressure, barg 20 o C Temperature at NTP conditions 1 atm Pressure at NTP conditions P, Differential pressure measured across tappings, psi ϵ, Expansibility factor Re D, Reynolds number m/s, Pipe velocity Corner Tap type β, Beta ratio C, Coefficient of discharge w, Overall pressure loss caused by orifice plate, kpa w, Overall pressure loss caused by orifice plate, psi d, mm, Orifice internal diameter d, inch, Orifice internal diameter Temperature at STP conditions Pressure at STP conditions Density at STP conditions CONCLUSIONS:
5 DOC. NO. CEPL-PC-001-CA-009 REV. 0 PROJECT NO. PO / 10 / PAGE NO. 5 of 7 Small Bore Orifice Sizing Calculation For Gas Services as per ASME-MFC-14M-2001 ATTACHMENT 1: CALCULATION BASIS / EQUATIONS The equations implemented in the spreadsheet are sourced from ASME MFC-14M-2001 and are given below. The notation is given below. C is the discharge coefficient. D1 has to be supplied in m D1 and D2 are the diameter of the pipe and orifice respectively (m) A1 and A2 are the cross sectional areas of the pipe and orifice (m 2 ) ΔP is the pressure drop across the orifice (Pa) P1 and P std are the upstream pressure and standard pressure T and T std are the gas temperature and standard temperature is the ρ is the gas (kg/m 3 ) μ is the gas viscosity (Pa s) V1 is the liquid velocity in the pipe (m/s) R e1 is the Reynolds Number in the pipe β is the diameter ratio MW is the molecular weight of the gas (kg/mol) R is the universal gas constant (8314 J/kmol/K) γ is the specific heat ratio e is the gas expansivity Q is the volumetric flowrate (m 3 /s) Q std is the volumetric flowrate at standard conditions (m 3 /s)
6 DOC. NO. CEPL-PC-001-CA-009 REV. 0 PROJECT NO. PO / 10 / PAGE NO. 6 of 7 ISENTROPIC EXPONENT CORRECTION FACTOR, F K (Reference: Flow Measurement Engineering Handbook, 3rd edition, Richard W. Miller)
7 DOC. NO. CEPL-PC-001-CA-009 REV. 0 PROJECT NO. PO / 10 / PAGE NO. 7 of 7 EQUATIONS USED FOR CHOKED FLOW:
MCE380: Measurements and Instrumentation Lab
MCE380: Measurements and Instrumentation Lab Chapter 8: Flow Measurements Topics: Basic Flow Equations Flow Obstruction Meters Positive Displacement Flowmeters Other Methods Holman, Ch. 7 Cleveland State
More informationOrifice and Venturi Pipe Flow Meters
Orifice and Venturi Pipe Flow Meters by Harlan H. Bengtson, PhD, P.E. 1. Introduction Your Course Title Here The flow rate of a fluid flowing in a pipe under pressure is measured for a variety of applications,
More informationOrifice and Venturi Pipe Flow Meters
Orifice and Venturi Pipe Flow Meters For Liquid and Gas Flow by Harlan H. Bengtson, PhD, P.E. 1. Introduction Orifice and Venturi Pipe Flow Meters The flow rate of a fluid flowing in a pipe under pressure
More informationABSTRACT I. INTRODUCTION
2016 IJSRSET Volume 2 Issue 4 Print ISSN : 2395-1990 Online ISSN : 2394-4099 Themed Section: Engineering and Technology Analysis of Compressible Effect in the Flow Metering By Orifice Plate Using Prasanna
More informationAnnubar Primary Element Flow Calculations
Rosemount 485 Annubar Annubar Primary Element Flow Calculations ANNUBAR PRIMARY ELEMENT FLOW EQUATIONS The Annubar primary element flow equations are all derived from the hydraulic equations which are
More informationTHE GEOTHERMAL TWO-PHASE ORIFICE PLATE
THE EOTHERMAL TWO-PHASE ORIFICE PLATE Mohamad Husni Mubarok 1,2 *, Sadiq J. Zarrouk 1 and John E. Cater 1 1 Department of Engineering Science, The University of Auckland, Private Bag 9219, Auckland, New
More informationPOWER UNDERSTANDING MEASUREMENT UNCERTAINTY IN DP FLOW DEVICES
Proceedings of the ASME 2014 Power Conference POWER2014 July 28-31, 2014, Baltimore, Maryland, USA POWER2014-32205 UNDERSTANDING MEASUREMENT UNCERTAINTY IN DP FLOW DEVICES Michael S. Hering Rosemount DP
More informationMeasurement of fluid flow in closed conduits
BRITISH STANDARD BS 1042-1.4: 1992 Incorporating Amendment No. 1 Measurement of fluid flow in closed conduits Part 1: Pressure differential devices Section 1.4 Guide to the use of devices specified in
More informationThe Expansibility Factor Equations in ISO and ISO : Do They Deliver What They Promise?
The Expansibility Factor Equations in ISO 567-2 and ISO 567-4: Do They Deliver What They Promise? Michael Reader-Harris, NEL INTRODUCTION The expansibility factor equations in ISO 567-2:2003 [] and ISO
More informationWater Circuit Lab. The pressure drop along a straight pipe segment can be calculated using the following set of equations:
Water Circuit Lab When a fluid flows in a conduit, there is friction between the flowing fluid and the pipe walls. The result of this friction is a net loss of energy in the flowing fluid. The fluid pressure
More information405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test Data Book and Flow Handbook
405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test Book and Flow Handbook www.rosemount.com 405 and 1595 405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test
More information405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test Data Book and Flow Handbook
Reference Manual 405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test Book and Flow Handbook www.rosemount.com Reference Manual 405 and 1595 405 Compact Orifice Series and 1595 Conditioning
More information405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test Data Book and Flow Handbook
405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test Book and Flow Handbook www.rosemount.com 405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test Book NOTICE Read
More informationERRATA CRANE FLOW OF FLUIDS THROUGH VALVES, FITTINGS AND PIPE TECHNICAL PAPER NO. 410 METRIC VERSION
ERRATA CRANE FLOW OF FLUIDS THROUGH VALVES, FITTINGS AND PIPE TECHNICAL PAPER NO. 410 METRIC VERSION CONTACT Please address questions and possible errata to solutions@flowoffluids.com FRONT MATTER PAGE
More informationModel Selection 1. Process Valves. Air. Vacuum
Process Valves Model Selection For product specifications such as maximum operating pressure differentials and operating temperature ranges, refer to the relevent pages of each product. Air One-touch fittings
More informationNORTH SEA FLOW MEASUREMENT WORKSHOP 2004 In. St Andrews, Scotland
NORTH SEA FLOW MEASUREMENT WORKSHOP 2004 In St Andrews, Scotland From the 26 th to 28 th October, 2004 Tests of the V-Cone Flow Meter at Southwest Research Institute and Utah State University in Accordance
More informationProduct Discontinued
Manual Supplement Product Discontinued Rosemount 3095FC Rosemount 3095FC User Programs INTRODUCTION OPERATION The Rosemount 3095FC is a multivariable transmitter that measures differential pressure, line
More informationABSTRACT I. INTRODUCTION
2017 IJSRSET Volume 3 Issue 3 Print ISSN: 2395-1990 Online ISSN : 2394-4099 Themed Section: Engineering and Technology CFD Analysis of Flow through Single and Multi Stage Eccentric Orifice Plate Assemblies
More informationFundamentals of Gas Dynamics (NOC16 - ME05) Assignment - 10 : Solutions
Fundamentals of Gas Dynamics (NOC16 - ME05) Assignment - 10 : Solutions Manjul Sharma & Aswathy Nair K. Department of Aerospace Engineering IIT Madras April 18, 016 (Note : The solutions discussed below
More informationCompressible Gas Flow
Compressible Gas Flow by Elizabeth Adolph Submitted to Dr. C. Grant Willson CHE53M Department of Chemical Engineering The University of Texas at Austin Fall 008 Compressible Gas Flow Abstract In this lab,
More informationExperiment No.4: Flow through Venturi meter. Background and Theory
Experiment No.4: Flow through Venturi meter Background and Theory Introduction Flow meters are used in the industry to measure the volumetric flow rate of fluids. Differential pressure type flow meters
More informationAEROSPACE ENGINEERING DEPARTMENT. Second Year - Second Term ( ) Fluid Mechanics & Gas Dynamics
AEROSPACE ENGINEERING DEPARTMENT Second Year - Second Term (2008-2009) Fluid Mechanics & Gas Dynamics Similitude,Dimensional Analysis &Modeling (1) [7.2R*] Some common variables in fluid mechanics include:
More informationFluid Flow Analysis Penn State Chemical Engineering
Fluid Flow Analysis Penn State Chemical Engineering Revised Spring 2015 Table of Contents LEARNING OBJECTIVES... 1 EXPERIMENTAL OBJECTIVES AND OVERVIEW... 1 PRE-LAB STUDY... 2 EXPERIMENTS IN THE LAB...
More informationEXPERIMENT NO. 4 CALIBRATION OF AN ORIFICE PLATE FLOWMETER MECHANICAL ENGINEERING DEPARTMENT KING SAUD UNIVERSITY RIYADH
EXPERIMENT NO. 4 CALIBRATION OF AN ORIFICE PLATE FLOWMETER MECHANICAL ENGINEERING DEPARTMENT KING SAUD UNIVERSITY RIYADH Submitted By: ABDULLAH IBN ABDULRAHMAN ID: 13456789 GROUP A EXPERIMENT PERFORMED
More informationMechanical Measurements and Metrology Prof. S. P. Venkateshan Department of Mechanical Engineering Indian Institute of Technology, Madras
Mechanical Measurements and Metrology Prof. S. P. Venkateshan Department of Mechanical Engineering Indian Institute of Technology, Madras Module - 3 Lecture - 33 Measurement of Volume and Mass Flow Rate
More informationIntegral V-Cone Flowmeter VD series
TRANSMITTER DIRECTLY MOUNTED! SIMPLE AND EASY INSTALLATION Integral V-Cone Flowmeter VD series OUTLINE VD series Integral V-Cone Flowmeter is a differential pressure type flowmeter. Unlikely to existing
More informationAlden Test Results On AMITY Insert Venturi
Alden Test Results On AMITY Insert Venturi Richard W. Miller PhD, PE A laboratory test was performed on an AMITY designed insert Venturi at the Alden on October 27, 2009 to obtain the coefficient of discharge
More informationV-Cone Flowmeter DATASHEET
V-Cone Flowmeter ATASHEET JUNHO 013 IntraCone Cone Flow Meter Type: ICM etail: Cone-Element Technical Information 05/011 FLOW THE SPECIALIST IN LEVEL AN FLOW Cone Flow Meter Technical Information Intra-Automation
More informationModel Selection 1. Process Valves
Process Valves Model Selection For product specifications such as maximum operating pressure differentials and operating temperature ranges, refer to the relevent pages of each product. Air, Inert gas
More informationLecture 22. Mechanical Energy Balance
Lecture 22 Mechanical Energy Balance Contents Exercise 1 Exercise 2 Exercise 3 Key Words: Fluid flow, Macroscopic Balance, Frictional Losses, Turbulent Flow Exercise 1 It is proposed to install a fan to
More informationFlow Measurement in Pipes and Ducts
Flow Measurement in Pipes and Ducts Course No: M04-040 Credit: 4 PDH Harlan H. Bengtson, Ph.D., P.E. Continuing Education and Development, Inc. 9 Greyridge Farm Court Stony Point, NY 10980 P: (877) 322-5800
More informationFLUID MECHANICS D203 SAE SOLUTIONS TUTORIAL 2 APPLICATIONS OF BERNOULLI SELF ASSESSMENT EXERCISE 1
FLUID MECHANICS D203 SAE SOLUTIONS TUTORIAL 2 APPLICATIONS OF BERNOULLI SELF ASSESSMENT EXERCISE 1 1. A pipe 100 mm bore diameter carries oil of density 900 kg/m3 at a rate of 4 kg/s. The pipe reduces
More information[Prasanna m a*et al., 5(6): July, 2016] ISSN: IC Value: 3.00 Impact Factor: 4.116
IJESRT INTERNATIONAL JOURNAL OF ENGINEERING SCIENCES & RESEARCH TECHNOLOGY NUMERICAL ANALYSIS OF COMPRESSIBLE EFFECT IN THE FLOW METERING BY CLASSICAL VENTURIMETER Prasanna M A *, Dr V Seshadri, Yogesh
More informationSST Tag: Message: (32 characters)
86-1-4738, Rev AA June 213 ROSEMOUNT 395FB Information Customer: Rosemount 395 MultiVariable Configuration Data Sheet Contact Name: Customer Phone: Customer Approval Sign-Off: Model No (1) Customer Fax:
More informationLaboratory work No 2: Calibration of Orifice Flow Meter
Laboratory work No : Calibration of Orifice Flow Meter 1. Objective Calibrate the orifice flow meter and draw the graphs p = f 1 (Q) and C d = f (Re ).. Necessary equipment 1. Orifice flow meter. Measuring
More informationAbout this document. This document contains screenshots of software available from Cheresources.com. You can find this title in our online store at:
About this document This document contains screenshots of software available from Cheresources.com. You can find this title in our online store at: http://www.cheresources.com/cheplusstore/catalogue.php
More informationFlow Measurement in Pipes and Ducts COURSE CONTENT
Flow Measurement in Pipes and Ducts Dr. Harlan H. Bengtson, P.E. COURSE CONTENT 1. Introduction This course is about measurement of the flow rate of a fluid flowing under pressure in a closed conduit.
More informationPrediction of Performance Characteristics of Orifice Plate Assembly for Non-Standard Conditions Using CFD
International Journal of Engineering and Technical Research (IJETR) ISSN: 2321-0869, Volume-3, Issue-5, May 2015 Prediction of Performance Characteristics of Orifice Plate Assembly for Non-Standard Conditions
More information04/01/1998 Developments in DP Flowmeters By Jesse Yoder
04/01/1998 Developments in DP Flowmeters By Jesse Yoder Developments in DP Flowmeters Improvements in Primary Elements Are Keeping Differential Pressure Flowmeters the First Choice for Many Process Applications
More information2/3 Port Valves for Fluid Control Model Selection 1
/ Port Valves for Control Model Selection Model Selection For product specifications such as maximum operating pressure differentials and operating temperature ranges, refer to the relevent pages of each
More informationUse N 1, if sizing the valve for a flow rate in volumetric units (gpm or m 3 /h).
ANSI/ISA/IEC Valve Sizing Catalog 2 March 202 Page 2 Introduction Standardization activities for control valve sizing can be traced back to the early 960's when an American trade association, the Fluids
More informationFLOW MEASUREMENT IN PIPES EXPERIMENT
University of Leicester Engineering Department FLOW MEASUREMENT IN PIPES EXPERIMENT Page 1 FORMAL LABORATORY REPORT Name of the experiment: FLOW MEASUREMENT IN PIPES Author: Apollin nana chaazou Partner
More informationLecture23. Flowmeter Design.
Lecture23 Flowmeter Design. Contents of lecture Design of flowmeter Principles of flow measurement; i) Venturi and ii) Orifice meter and nozzle Relationship between flow rate and pressure drop Relation
More informationFlow Measurement in Pipes and Ducts COURSE CONTENT
Flow Measurement in Pipes and Ducts Dr. Harlan H. Bengtson, P.E. COURSE CONTENT 1. Introduction This course is about measurement of the flow rate of a fluid flowing under pressure in a closed conduit.
More informationDELTA FLOWMETER FOR GAS SERVICE (INSERTION TYPE) MODEL VF SERIES
DETA FOWMETER FOR GAS SERVICE (INSERTION TYPE) MODE VF SERIES GENERA SPECIFICATION GS. No. GBD0-0-E GENERA In the thermistor type Delta meter, a probe inserted in the pipeline detects the representative
More informationMEDIDAS EN FLUIDOS. INEL 5205 Instrumentación. Monday, November 19, 12
MEDIDAS EN FLUIDOS INEL 5205 Instrumentación SENSORES DE PRESIÓN Unidades de Presión 1 psi! 1 lbf/in 2 = 6,894.76! Pa = 6,894.76!newton/m 2 = 68.948 10 3!bar (1 bar = 10 5 Pa) = 68.046 10 3!atm = 51.715
More informationWORKBOOK FOR CHEMICAL REACTOR RELIEF SYSTEM SIZING ANNEX 10 NOMENCLATURE A cross-sectional flow area of relief system (m 2 ) A actual actual cross-sectional area of safety valve nozzle (m 2 ) A approx
More information2/3 Port Valves for Fluid Control Model Selection 1
/ Port Valves for Control Model Selection Model Selection For product specifications such as maximum operating pressure differentials and operating temperature ranges, refer to the relevent pages of each
More informationPipe Flow/Friction Factor Calculations using Excel Spreadsheets
Pipe Flow/Friction Factor Calculations using Excel Spreadsheets Harlan H. Bengtson, PE, PhD Emeritus Professor of Civil Engineering Southern Illinois University Edwardsville Table of Contents Introduction
More informationCHE-201. I n t r o d u c t i o n t o Chemical E n g i n e e r i n g. I N S T R U CTOR: D r. N a b e e l S a l i m A b o - Ghander.
I n t r o d u c t i o n t o Chemical E n g i n e e r i n g CHE-201 I N S T R U CTOR: D r. N a b e e l S a l i m A b o - Ghander C h a p t e r 3 Processes and Process Variables Introduction What is a process?
More informationCampus Mail Box. Circle One: Richards 03 Richards 04 Lui 05 Lui - 06
ES 202 - Exam I Winter 2002-2003 Richards/Lui Name: Campus Mail Box Circle One: Richards 03 Richards 04 Lui 05 Lui - 06 Problem 1 Problem 2 ( 10 ) ( 45 ) Problem 3 ( 45 ) TOTAL ( 100 ) General Comments
More informationLecture 13 Flow Measurement in Pipes. I. Introduction
Lecture 13 Flow Measurement in Pipes I. Introduction There are a wide variety of methods for measuring discharge and velocity in pipes, or closed conduits Many of these methods can provide very accurate
More informationANSI/ISA/IEC Valve Sizing Introduction and Sizing Valves for Liquids
ANSI/ISA/IEC Valve Sizing Introduction and Sizing Valves for Liquids Standardization activities for control valve sizing can be traced back to the early 960 s when an American trade association, the Fluids
More informationFLUID MECHANICS D203 SAE SOLUTIONS TUTORIAL 2 APPLICATIONS OF BERNOULLI SELF ASSESSMENT EXERCISE 3
FLUI MEHNIS 0 SE SOLUTIONS TUTORIL PPLITIONS OF ERNOULLI SELF SSESSMENT EXERISE Take the density of water to be 997 kg/m throghot nless otherwise stated.. Ventri meter is 50 mm bore diameter at inlet and
More informationIX. COMPRESSIBLE FLOW. ρ = P
IX. COMPRESSIBLE FLOW Compressible flow is the study of fluids flowing at speeds comparable to the local speed of sound. This occurs when fluid speeds are about 30% or more of the local acoustic velocity.
More informationLarge Rocket Engine Environments
Balanced Flow Metering and Conditioning Technology for Fluid Systems (Space Liquid Propulsion Systems) for 2006 Instrumentation Symposium for the Process Industries Anthony R. Kelley EV23 Advanced Sensors
More informationCHAPTER (13) FLOW MEASUREMENTS
CHAPTER (13) FLOW MEASUREMENTS 09/12/2010 Dr. Munzer Ebaid 1 Instruments for the Measurements of Flow Rate 1. Direct Methods: Volume or weight measurements. 2. Indirect Methods: Venturi meters, Orifices
More informationDischarge Coefficient Prediction for Multi hole Orifice Plate in a Turbulent Flow through Pipe: Experimental and Numerical Investigation
Discharge Coefficient Prediction for Multi hole Orifice Plate in a Turbulent Flow through Pipe: Experimental and Numerical Investigation [] Mahendra Babu.K.J, [2] Dr. Gangadhara Gowda C.J, [3] Ranjith
More informationFlowmeter Discharge Coefficient Estimation
Bankston 1 Flowmeter Discharge Coefficient Estimation Elizabeth Bankston Team 1 Abstract An Edibon FME18 Flow Meter demonstration system was used to obtain experimental values for this experiment. The
More informationA Novel Equation for Calculating the Expansion Factor of Gas in Control Valve Sizing by considering the Z-factor
International Gas Union Research Conference Copenhagen, September 7-9, 204 A Novel Equation for Calculating the Epansion Factor of Gas in Control Valve Sizing by considering the Z-factor Nasser Faraz *,
More informationLab Section Date. ME4751 Air Flow Rate Measurement
Name Lab Section Date ME4751 Air Flow Rate Measurement Objective The objective of this experiment is to determine the volumetric flow rate of air flowing through a pipe using a Pitot-static tube and a
More informationN. Zhang, W.-J. Yang and Y. Xu Department of Mechanical Engineering and Applied Mechanics, The University of Michigan, Ann Arbor, MI 48109, USA
Experiments in Fluids 1, 25 32 (1993) Experiments m Fluids 9 Springer-Verlag 1993 Flow characteristics in flow networks N. Zhang, W.-J. Yang and Y. Xu Department of Mechanical Engineering and Applied Mechanics,
More informationProcess Gas Flow Measurement and Performance Evaluation API TECHNICAL REPORT 2571 SECOND EDITION DRAFT, FEBRUARY 2018
Process Gas Flow Measurement and Performance Evaluation API TECHNICAL REPORT 2571 SECOND EDITION DRAFT, FEBRUARY 2018 (Note: modify document as needed once final proposal on name change is agreed, i.e.
More informationChemical Engineering 3P04 Process Control Tutorial # 1 Learning goals
Chemical Engineering 3P04 Process Control Tutorial # 1 Learning goals 1. Sensor Principles with the flow sensor example 2. The typical manipulated variable: flow through a conduit Sensors: We need them
More informationExergy Analysis of Solar Air Collector Having W Shaped Artificial Roughness
Advances in Materials Science and Mechanical Engineering Research Volume 1, Number 1 (2015), pp. 25-32 International Research Publication House http://www.irphouse.com Exergy Analysis of Solar Air Collector
More informationExperiment (4): Flow measurement
Experiment (4): Flow measurement Introduction: The flow measuring apparatus is used to familiarize the students with typical methods of flow measurement of an incompressible fluid and, at the same time
More informationName. Chemical Engineering 150A Mid-term Examination 1 Spring 2013
Name Chemical Engineering 150A Mid-term Examination 1 Spring 2013 Show your work. Clearly identify any assumptions you are making, indicate your reasoning, and clearly identify any variables that are not
More informationFINAL DRAFT: October 25, 2010 API TECHNICAL REPORT FUEL GAS MEASUREMENT. FINAL DRAFT: October 25, 2010 Page 0
FINAL DRAFT: October 25, 2010 API TECHNICAL REPORT FUEL GAS MEASUREMENT FINAL DRAFT: October 25, 2010 Page 0 Foreword Add API boiler plate FINAL DRAFT: October 25, 2010 Page 1 TABLE OF CONTENTS Introduction...
More informationCHAPTER 3 BASIC EQUATIONS IN FLUID MECHANICS NOOR ALIZA AHMAD
CHAPTER 3 BASIC EQUATIONS IN FLUID MECHANICS 1 INTRODUCTION Flow often referred as an ideal fluid. We presume that such a fluid has no viscosity. However, this is an idealized situation that does not exist.
More informationPART II. Fluid Mechanics Pressure. Fluid Mechanics Pressure. Fluid Mechanics Specific Gravity. Some applications of fluid mechanics
ART II Some applications of fluid mechanics Fluid Mechanics ressure ressure = F/A Units: Newton's per square meter, Nm -, kgm - s - The same unit is also known as a ascal, a, i.e. a = Nm - ) English units:
More informationSAMPLE FORMAL REPORT A
SAMPLE FORMAL REPORT A Chemical Engineering 4903 and 4905 The following sample laboratory formal report is not intended to represent the scope and depth of the projects assigned to students. It is an edited
More informationSELECCIÓN DE CAUDALIMETROS. Tablas de Fabricantes
SELECCIÓN DE CAUDALIMETROS Tablas de Fabricantes Flow Meter Selection Table http://www.instrumart.com/content.aspxcontentid=219 Página 1 de 1 17/09/2007 KEY Best for this application OK with some exceptions
More informationProcesses and Process Variables
Processes and Process Variables Processes and Process Variables Processes and Process Variables Processes and Process Variables average molecular weight = M y i M i Component Mol Fraction, y i M i N 2
More informationFluid Dynamics Exercises and questions for the course
Fluid Dynamics Exercises and questions for the course January 15, 2014 A two dimensional flow field characterised by the following velocity components in polar coordinates is called a free vortex: u r
More informationTurbulent Compressible Flow in a Slender Tube
Turbulent Compressible Flow in a Slender Tube Kurt O. Lund* 1, and Christine M. Lord 2 1 COMSOL Consultant, 2 Lord Engineering Corp. *Corresponding author: 135 Sixth Street, Del Mar, CA 92014, kurtlund@roadrunner.com
More informationFE Exam Fluids Review October 23, Important Concepts
FE Exam Fluids Review October 3, 013 mportant Concepts Density, specific volume, specific weight, specific gravity (Water 1000 kg/m^3, Air 1. kg/m^3) Meaning & Symbols? Stress, Pressure, Viscosity; Meaning
More informationSignature: (Note that unsigned exams will be given a score of zero.)
Neatly print your name: Signature: (Note that unsigned exams will be given a score of zero.) Circle your lecture section (-1 point if not circled, or circled incorrectly): Prof. Dabiri Prof. Wassgren Prof.
More informationAN INDIRECT MEASUREMENT METHOD OF TRANSIENT PRESSURE AND FLOW RATE IN A PIPE USING STEADY STATE KALMAN FILTER
AN INDIRECT MEASUREMENT METHOD OF TRANSIENT PRESSURE AND FLOW RATE IN A PIPE USING STEADY STATE KALMAN FILTER Akira OZAWA*, Kazushi SANADA** * Department of Mechanical Engineering, Graduate School of Mechanical
More informationDiagnostic System for Venturi Meters
Diagnostic System for Venturi Meters Richard Steven, DP Diagnostics PO Box 121, Windsor, Colorado, 80550, Colorado Tel: 1-970-686-2189, e-mail: rsteven@dpdiagnostics.com 1. Introduction Venturi flow meters
More informationMAE 320 THERODYNAMICS FINAL EXAM - Practice. Name: You are allowed three sheets of notes.
50 MAE 320 THERODYNAMICS FINAL EXAM - Practice Name: You are allowed three sheets of notes. 1. Fill in the blanks for each of the two (Carnot) cycles below. (a) 5 a) Heat engine or Heat pump/refrigerator
More informationCVE 372 HYDROMECHANICS EXERCISE PROBLEMS
VE 37 HYDROMEHNIS EXERISE PROLEMS 1. pump that has the characteristic curve shown in the accompanying graph is to be installed in the system shown. What will be the discharge of water in the system? Take
More informationComputation of pressure loss for differential producing flowmeters
XXVI. ASR '00 Seminar, Instruments and Control, Ostrava, April 6-7, 00 Paper 5 Computation of pressure loss for differential producing flowmeters ORLÍKOVÁ, Soňa Ing., Ústav automatizace a měřicí techniky,
More informationP & I Design Limited. 2 Reed Street, Gladstone Industrial Estate, Thornaby, TS17 7AF. Tel: +44 (0) Fax: +44 (0)
ump Sizing & Rating USER MANUAL & I Design Limited Reed Street, Gladstone Industrial Estate, Thornaby, TS7 7AF. Tel: +44 (0) 64 67444 Fax: +44 (0) 64 66447 www.pidesign.co.uk Support: sales@pidesign.co.uk
More informationUniversität Duisburg-Essen Fakultät für Ingenieurwissenschaften WS 2012 Maschinenbau, IVG, Thermodynamik Dr. M. A. Siddiqi
1 Universität Duisburg-Essen 3. Semester Fakultät für Ingenieurwissenschaften WS 2012 Maschinenbau, IVG, Thermodynamik Dr. M. A. Siddiqi THERMODYNAMICS LAB (ISE) Pressure Measurement 2 2 Pressure Measurement
More informationQ1 Give answers to all of the following questions (5 marks each):
FLUID MECHANICS First Year Exam Solutions 03 Q Give answers to all of the following questions (5 marks each): (a) A cylinder of m in diameter is made with material of relative density 0.5. It is moored
More informationMajor and Minor Losses
Abstract Major and Minor Losses Caitlyn Collazo, Team 2 (1:00 pm) A Technovate fluid circuit system was used to determine the pressure drop across a pipe section and across an orifice. These pressure drops
More informationME 4600:483 Lab Notes Revised 11/16/2015. Flow Measurement
Table of Contents Flow Measurement Flow Measurement... 1 I. Objective... 1 II. Apparatus... 1 III. Principles and Background... 1 Pitot-Static Tubes... 2 Orifice Plates and Unrecoverable Losses... 4 Flow
More informationFDE 211 MATERIAL & ENERGY BALANCES. Instructor: Dr. Ilgin Paker Yikici Fall 2015
FDE 211 MATERIAL & ENERGY BALANCES Instructor: Dr. Ilgin Paker Yikici Fall 2015 Meet & Greet Hello! My name is I am from 2 Class Overview Units & Conversions Process & Process Variables Process Units &
More informationHead loss coefficient through sharp-edged orifices
Head loss coefficient through sharp-edged orifices Nicolas J. Adam, Giovanni De Cesare and Anton J. Schleiss Laboratory of Hydraulic Constructions, Ecole Polytechnique fédérale de Lausanne, Lausanne, Switzerland
More informationIAPWS-IF97 Water and Steam Properties DEMO VERSION USER GUIDE. Copyright Fluidika Techlabs S de RL de CV. All Rights Reserved.
IAPWS-IF97 Water and Steam Properties Excel Add-In Library DEMO VERSION USER GUIDE Windows Operating System SI and I-P Units Version 2.0 Copyright 2015-2019 Fluidika Techlabs S de RL de CV. All Rights
More informationWTS Table of contents. Layout
Table of contents Thermal and hydraulic design of shell and tube heat exchangers... 2 Tube sheet data... 4 Properties of Water and Steam... 6 Properties of Water and Steam... 7 Heat transfer in pipe flow...
More information5 ENERGY EQUATION OF FLUID MOTION
5 ENERGY EQUATION OF FLUID MOTION 5.1 Introduction In order to develop the equations that describe a flow, it is assumed that fluids are subject to certain fundamental laws of physics. The pertinent laws
More informationMechanical Engineering Programme of Study
Mechanical Engineering Programme of Study Fluid Mechanics Instructor: Marios M. Fyrillas Email: eng.fm@fit.ac.cy SOLVED EXAMPLES ON VISCOUS FLOW 1. Consider steady, laminar flow between two fixed parallel
More informationSMV 3000 Smart Multivariable Flow Transmitter
SMV 3000 Smart Multivariable Flow Transmitter Measurements and Calculations: Differential Pressure Absolute or Gauge Pressure Process Temperature via 100 ohm Pt. RTD or Type J,K,T or E Thermocouple Mass
More informationPro-V Multivariable Flowmeter Model M23 Insertion Vortex
Pro-V Multivariable Flowmeter Model M23 Insertion Vortex Pro-V TM Advantage: Volumetric or mass flow monitoring of most liquids, gases, and steam Multivariable meter delivers mass flow, temperature, pressure,
More informationOmega Chemicals Emissions Testing Report
Omega Chemicals 18-Feb-2015 Doc No. 60336610_1.1_RPT Omega Chemicals Emissions Testing Report February 2015 NATA ACCREDITATION No. 2778 (14391) Accredited for compliance with ISO/IEC 17025 This document
More informationMechanical Engineering Department Third year class Gas Dynamics Tables Lecturer: Dr.Naseer Al-Janabi
Mechanical Engineering Department Third year class Gas Dynamics Tables Lecturer: Dr.Naseer Al-Janabi Ref. Fundamentals of Gas Dynamics, 2e - R. Zucker, O. Biblarz Appendixes A. B. C. D. E. F. G. H. I.
More informationCalibration of Orifice Flow Meter and Venturi Flow Meter
Calibration of Orifice Flow Meter and Venturi Flow Meter D. Till Abstract Orifice and venturi flow meters decrease the pressure of a fluid b increasing its velocit as it flows through them. This is done
More informationSizing of Gas Pipelines
Sizing of Gas Pipelines Mavis Nyarko MSc. Gas Engineering and Management, BSc. Civil Engineering Kumasi - Ghana mariiooh@yahoo.com Abstract-In this study, an effective approach for calculating the size
More informationHydraulics and hydrology
Hydraulics and hydrology - project exercises - Class 4 and 5 Pipe flow Discharge (Q) (called also as the volume flow rate) is the volume of fluid that passes through an area per unit time. The discharge
More information