TABLE OF CONTENT. Designation code. Circuit diagrams. Sensors. How to read sensor designations. Connection according to EN
|
|
- Bethanie Whitehead
- 5 years ago
- Views:
Transcription
1 TLE OF CONTENT code How to read sensor designations Circuit diagrams Connection according to EN Sensors Cylinder G6,5 Cylinder M8 Square Q8 Cylinder M2 Square Q2 Cylinder M8 Cylinder G20 Cylinder M0 Cylinder G utomática Electrónica y Control, S.L. Lacy, 0 cc Sabadell (arcelona) Tel Fax info@automatica.cat
2 Mounting Quasiflush mounting x Sn The sensors in this catalogue must not be mounted flush into conductive materials, but have to protrude by X. Flush mounting in nonconductive materials is allowed. X Steel Other metals Other material X = 0,2 X = 0, X = 0 Material Nonflush mounting S n = Switching distance = iameter of the sensors Sn 2
3 ESIGNTION COE Example: K J 0 M 0 M 5 P S V X = Working principle C H J M N R W coustic cceleration sensor Capacitive Strain gauge sensor Halleffect Inductive JR JF JG J Magnetoresistive Inclination sensor Reedcontact ngle sensor 2 = Switching distance / range = esign G M Q = Housing diameter / edge length Inductive ring Inductive surface Inductive slot Metalface Ring housing Cylindrical housing without thread Cylindrical housing with metrical thread Square housing 5 = Housing material luminium E Stainless steel K Plastic M rass, nickel plated T PTFE 6 = Installation N Shielded Non 7 = Tube length 8 = Operating voltage Z VZ C alternating current voltage C direct current voltage C/C all voltages 9 = Type of output signal N nalog N N P Z Namur Two wire 0 = Function I Ö S U Changeover Impulse output N.C. N.O. Switchable = Connection V V2 V2/ V V V6 V7 V8 V9 V0 V V2 VE RS22 PG Mxx NI NU CN M8 screw/snapin M2 metal M2 plastic M5 metal mphenol Tuchel rad Harrison Valve connector type M8 snapin only Torson Valve connector type C C connector /2'' UNF M8 plastic Euchner connector ata interface Thread joint PG Thread joint metrical others as requested 2 = dditional marks M FE HT NF SF T W X Current output Voltage output CNbus interface Sensing face in centre Reduction to steel / iron High temperature Reduction to nonferrous metal Weld field immune Enlarged temperature range ngled sensing face / angled cable exit Customized design with detailled description
4 CIRCUIT IGRMS Circuit diagram for Cable / clamp connection Connector V... V9 PS C N.O. N () K () U () PÖ C N.C. N () K (2) U () 2 P C changeover N () K () WH (2) U () 2 PU C NO/NC switchable N () SW () U () NS C N.O. N () K () U () NÖ C N.C. N () K (2) U () 2 N C changeover N () K () WH (2) U () 2 NU C NO/NC switchable N () SW () U () N Namur EN N () U (2) 2 ZS C twowire N.O. N () U () ZÖ C twowire N.C. N () U (2) 2 ZS/VZS C/C twowire N.O. N () U () GN/YE ZÖ/VZÖ C/C twowire N.C. N () U (2) GN/YE 2 nalog N () K () U ()
5 CYLINER G6,5 General data Operating voltage U b Ripple voltage of U b Voltage drop U d Max. load current Offstate current I 0 Residual current Max. switching frequency f Hysteresis H Repeatability R Operating temperature T a Temperature drift Protection class EMVstandard Switching state Housing material Front cap 0V... 0V C 0% V 200m 0m 0μ 000Hz 5% (Sr) 2% (Sr) 25 C C 0% (Sr) IP67 according to IEC brass, nickelplated POM The drawings of these sensors are shown on the following page. Selection chart rticle number switching distance mm Mounting Output signal Connection rawing (next page) SJG6,5M5PS SJG6,5M5PÖ SJG6,5M5NS SJG6,5M5NÖ SJG6,5M60PSV SJG6,5M60PÖV SJG6,5M60NSV SJG6,5M60NÖV switching distance 6mm SJ6G6,5MN5PS SJ6G6,5MN5PÖ SJ6G6,5MN5NS SJ6G6,5MN5NÖ SJ6G6,5MN60PSV SJ6G6,5MN60PÖV SJ6G6,5MN60NSV SJ6G6,5MN60NÖV non non non non non non non non Other cable lengths as requested. 5
6 CYLINER G6,5 imensions ) 5 ) 60 = 6,5 = 6,5 M8 x ) ) 56 = 6,5 = 6,5 M8 x all data in mm 6
7 CYLINER M8 General data Operating voltage U b Ripple voltage of U b Voltage drop U d Max. load current Offstate current I 0 Residual current Max. switching frequency f Hysteresis H Repeatability R Operating temperature T a Temperature drift Protection class EMVstandard Switchiung state Housing material Front cap 0V... 0V C 0% V 200m 0m 0μ 000Hz 5% (Sr) 2% (Sr) 25 C C 0% (Sr) IP67 according to IEC brass, nickelplated (except for KJM8E... stainless steel) KJ... P 6.6 KJ6... POM SJ6... POM The selection chart of these sensors is shown on the following page. imensions ) ) M8 x M8 x M8 x ) ) 60 6 M8 x M8 x M8 x C) 70 C) M8 x M2 x M8 x M2 x all data in mm 7
8 CYLINER M8 Selection chart rticle number switching distance mm Mounting Output signal Connection rawing (next page) KJM8M5PS KJM8M5PÖ KJM8M5NS KJM8M5NÖ KJM8E60PSV KJM8E60PÖV KJM8E60NSV KJM8E60NÖV KJM8M70PSV2 SJM8M70PÖV2 SJM8M70NSV2 SJM8M70NÖV2 C C C C switching distance 6mm KJ6M8MN5PS SJ6M8MN5PÖ KJ6M8MN5NS SJ6M8MN5NÖ KJ6M8MN60PSV SJ6M8MN60PÖV SJ6M8MN60NSV SJ6M8MN60NÖV KJ6M8MN70PSV2 SJ6M8MN70PÖV2 SJ6M8MN70NSV2 SJ6M8MN70NÖV2 non non non non non non non non non non non non Other cable lengths as requested. 8
9 SQURE Q8 General data Mounting Operating voltage U b Ripple voltage of U b Voltage drop U d Max. load current Offstate current I 0 Residual current Max. switching frequency f Switching distance Hysteresis H Repeatability R Operating temperature T a Temperature drift Protection class EMVstandard Switching state Housing material Front cap 0V... 0V C 0% V 200m 0m 0μ 000Hz mm 5% (Sr) 2% (Sr) 25 C C 0% (Sr) IP67 according to IEC brass, nickelplated POM The drawings of these sensors are shown on the following page. Selection chart rticle number Output signal Connection KJQ8M0PS SJQ8M0PÖ KJQ8M0NS SJQ8M0NÖ KJQ8M60PSV SJQ8M60PÖV KJQ8M60NSV SJQ8M60NÖV SJQ8M0PSM SJQ8M0PÖM SJQ8M0NSM SJQ8M0NÖM SJQ8M60PSVM SJQ8M60PÖVM SJQ8M60NSVM SJQ8M60NÖVM 2m cable PVC x 05mm² 2m cable PVC x 05mm² 2m cable PVC x 05mm² 2m cable PVC x 05mm² 2m cable PVC x 05mm² 2m cable PVC x 05mm² 2m cable PVC x 05mm² 2m cable PVC x 05mm² rawing (next page) Other cable lenghts as requested. M active field in center. subject to modifications! 9
10 8x8 5 8x8 8 SQURE Q8 imensions ) M x 0,5 ) M x 0, x8 M x 0,5 M x 0,5 5 2, Connector M8 x ) M x 0,5 ) 0 M x 0, x8 M x 0,5 M x 0, , Connector M8 x all data in mm 0
11 CYLINER M2 General data Operating voltage U b Ripple voltage of U b Voltage drop U d Max. load current Offstate current I 0 Residual current Max. switching frequency f Switching distance Hysteresis H Repeatability R Operating temperature T a Temperature drift Protection class EMVstandard Switchiung state Housing material Front cap 0V... 0V C 0% V 200m 0m 0μ KJ Hz SJ Hz KJ Hz SJ Hz mm 5% (Sr) 2% (Sr) 25 C C 0% (Sr) IP67 according to IEC brass, nickelplated KJ6... POM SJ6... POM KJ0... PT SJ0... PT The drawings of these sensors are shown on the following page. Selection chart rticle number switching distance 6mm KJ6M2M50PS SJ6M2M50PÖ KJ6M2M50NS SJ6M2M50NÖ KJ6M2M68PSV2 SJ6M2M68PÖV2 SJ6M2M68NSV2 SJ6M2M68NÖV2 Mounting Output signal Connection rawing (next page) switching distance 0mm KJ0M2MN50PS KJ0M2MN50PÖ KJ0M2MN50NS KJ0M2MN50NÖ KJ0M2MN68PSV2 KJ0M2MN68PÖV2 KJ0M2MN68NSV2 KJ0M2MN68NÖV2 non non non non non non non non
12 CYLINER M2 imensions ) ) M2 x M2 x M2 ) ) M2 x M2 x M2 all data in mm 2
13 SQURE Q2 General data Mounting Operating voltage U b Ripple voltage of U b Voltage drop U d Max. load current Offstate current I 0 Residual current Max. switching frequency f Switching distance Hysteresis H Repeatability R Operating temperature T a Temperature drift Protection class EMVstandard Switchung state Housing material Front cap 0V... 0V C 0% 2V 200m 0m 0μ 000Hz 6mm 5% (Sr) 2% (Sr) 25 C C 0% (Sr) IP67 according to IEC brass, nickelplated POM The drawings of these sensors are shown on the following page. uswahltabelle rticle number SJ6Q2M50PS SJ6Q2M50PÖ SJ6Q2M50NS SJ6Q2M50NÖ SJ6Q2M60PSV SJ6Q2M60PÖV SJ6Q2M60NSV SJ6Q2M60NÖV SJ6Q2M50PSM SJ6Q2M50PÖM SJ6Q2M50NSM SJ6Q2M50NÖM SJ6Q2M60PSVM SJ6Q2M60PÖVM SJ6Q2M60NSVM SJ6Q2M60NÖVM Output signal Connection rawing (next page) Other cable lengths as requested. M active field in center.
14 7 7 SQURE Q2 imensions ) M x 0, M x 0,7 M x 0,7 60 ) M x 0, connector M8 x ) 6 M x 0,7 2 2 M x 0, M x 0,7 6 ) 2 2 M x 0, connector M8 x 0 all data in mm
15 CYLINER M8 General data Operating voltage U b Ripple voltage of U b Voltage drop U d Max. load current Offstate current I 0 Residual current Max. switching frequency f Hysteresis H Repeatability R Operating temperature T a Temperature drift Protection class EMVstandard Switching state Housing material Front cap 0V... 0V C 0% 2V 200m 0m 50μ KJ Hz SJ Hz KJ Hz SJ Hz 5% (Sr) 2% (Sr) 25 C C 0% (Sr) IP67 according to IEC brass, nickelplated PT The drawings of these sensors are shown on the next page. Selection chart rticle number switching distance 2mm Mounting Output signal Connection rawing (next page) KJ2M8M65PS SJ2M8M65PÖ KJ2M8M65NS SJ2M8M65NÖ KJ2M8M76PSV2 SJ2M8M76PÖV2 SJ2M8M76NSV2 SJ2M8M76NÖV2 switching distance 20mm KJ20M8MN65PS SJ20M8MN65PÖ KJ20M8MN65NS SJ20M8MN65NÖ KJ20M8MN76PSV2 SJ20M8MN76PÖV2 KJ20M8MN76NSV2 SJ20M8MN76NÖV2 non non non non non non non non Other cable lengths as requested. 5
16 CYLINER M8 imensions ) 50 5 ) M8 x M8 x M2 ) 2 5 ) M8 x M8 x M2 all data in mm 6
17 CYLINER G20 General data Operating voltage U b Ripple voltage of U b Voltage drop U d Max. load current Offstate current I 0 Residual current Max. switching frequency f Hysteresis H Repeatability R Operating temperature T a Temperature drift Protection class EMVstandard Switching state Housing material 0V... 0V C 0% 2V 200m 0m 0μ SJ Hz SJ Hz 5% (Sr) 2% (Sr) 25 C C 0% (Sr) IP67 according to IEC polycarbonate The drawings of these sensors are shown on the next page. Selection chart rticle number switching distance 2mm SJ2G20K80PS SJ2G20K80PÖ SJ2G20K80NS SJ2G20K80NÖ SJ2G20K92PSV2/ SJ2G20K92PÖV2/ SJ2G20K92NSV2/ SJ2G20K92NÖV2/ Mounting Output signal Connection rawing (next page) switching distance 20mm SJ20G20KN80PS SJ20G20KN80PÖ SJ20G20KN80NS SJ20G20KN80NÖ SJ20G20KN92PSV2/ SJ20G20KN92PÖV2/ SJ20G20KN92NSV2/ SJ20G20KN92NÖV2/ non non non non non non non non Other cable lengths as requested. 7
18 CYLINER G20 imensions ) = 20 ) = 20 M2 all data in mm 8
19 CYLINER M0 General data Operating voltage U b Ripple voltage of U b Voltage drop U d Max. load current Offstate current I 0 Residual current Max. switching frequency f Hysteresis H Repeatability R Operating temperature T a Temperature drift Protection class EMVstandard Switching state Housing material Front cap 0V... 0V C 0% 2V 200m 0m 50μ KJ Hz SJ Hz KJ Hz SJ Hz 5% (Sr) 2% (Sr) 25 C C 0% (Sr) IP67 according to IEC brass, nickelplated PT The drawings of these sensors are shown on the following page. Selection chart rticle number switching distance 22mm KJ22M0M66PS KJ22M0M66PÖ KJ22M0M66NS SJ22M0M66NÖ KJ22M0M76PSV2 SJ22M0M76PÖV2 SJ22M0M76NSV2 SJ22M0M76NÖV2 Mounting Output signal Connection 2m cable PVC x 0,5mm² 2m cable PVC x 0,5mm² 2m cable PVC x 0,5mm² 2m cable PVC x 0,5mm² rawing (next page) switching distance 0mm KJ0M0MN8PS SJ0M0MN8PÖ KJ0M0MN8NS SJ0M0MN8NÖ KJ0M0MN9PSV2 SJ0M0MN9PÖV2 SJ0M0MN9NSV2 SJ0M0MN9NÖV2 non non non non non non non non 2m cable PVC x 0,5mm² 2m cable PVC x 0,5mm² 2m cable PVC x 0,5mm² 2m cable PVC x 0,5mm² Other cable lengths as requested. 9
20 CYLINER M0 imensions ) 5 5 M0 x,5 ) M0 x,5 M2 ) M0 x,5 ) M0 x,5 M2 all data in mm 20
21 CYLINER G General data Operating voltage U b Ripple voltage of U b Voltage drop U d Max. load current Offstate current I 0 Residual current Max. switching frequency f Hysteresis H Repeatability R Operating temperature T a Temperature drift Protection class EMVstandard Switching state Housing material 0V... 0V C 0% 2V 200m 0m 0μ SJ Hz SJ Hz 5% (Sr) 2% (Sr) 25 C C 0% (Sr) IP67 according to IEC polycarbonate Selection chart rticle number switching distance 22mm SJ22GK80PS SJ22GK80PÖ SJ22GK80NS SJ22GK80NÖ Mounting Output signal Connection 2m cable PVC x 0,5mm² 2m cable PVC x 0,5mm² 2m cable PVC x 0,5mm² 2m cable PVC x 0,5mm² rawing (next page) switching distance 0mm SJ0GKN80PS SJ0GKN80PÖ SJ0GKN80NS SJ0GKN80NÖ non non non non 2m cable PVC x 0,5mm² 2m cable PVC x 0,5mm² 2m cable PVC x 0,5mm² 2m cable PVC x 0,5mm² Other cable lengths as requested. imensions = all data in mm 2
TABLE OF CONTENT Designation code
TLE OF CONTENT code How to read sensor designations Circuit diagrams according to EN 60752 Functional description Operating mode of capacitive sensors 5 pplications pplication areas of capacitive sensors
More informationTABLE OF CONTENT. ATEX Certificate. Designation code. Circuit diagrams. Sensors. Sensors. Explosion-proof sensors from Pulsotronic
TABLE OF CONTENT ATEX Certificate Explosionproof sensors from Pulsotronic code How to read sensor designations Circuit diagrams Connection according to EN 606 Sensors Cylinder M8 Cylinder M Cylinder M8
More informationDMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm
DMP P Industrial Pressure Transmitter Process Connections With Flush Welded Stainless Steel accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 % FSO Nominal pressure from 0... 00 mbar up
More informationCapacitive Sensors. Contents
Contents Capacitive sensors detect the change in capacitance caused by the approach of an object. Their advantage lies in the ability to detect virtually any material, from metals to oils. 4.2 Definitions,
More informationDMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor
DMP Industrial Pressure Transmitter for Low Pressure Stainless Steel Sensor accuracy according to IEC 60770: : 0.5 % FSO option: 0.5 / 0. % FSO Nominal pressure from 0... 00 mbar up to 0... 60 bar Output
More informationDMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm
DMP Pi Precision Pressure Transmitter pressure ports and process connections with flush welded stainless steel diaphragm accuracy according to IEC 600: 0, % FSO Nominal pressure from 0... 00 mbar up to
More informationSize A DIN EN
Size A DIN EN 70-0 Actuators 0 series DIN EN 70-0 +, + ow and high housing Degree of protection IP6 Wired versions Moulded versions Degree of protection IP67 Contacts Thread Cable outlet Ordering-No. Female
More informationPressure. 1 Fitting PA R - N R2
INTERNAL STRUCTURE (R 1/4) 4 1 2 3 FEATURES High corrosion resistance and drip-proof construction port attachment made of Proven IP-65 grade gauge body (IP-65 in accordance with IEC) Standard product provides
More informationDS 200P. Electronic Pressure Switch. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm
Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm accuracy according to IEC 600: standard: 0. % FSO option: 0. % FSO Nominal pressure from 0... 00 mbar up to 0... 0 bar
More informationDMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm
DMP Pi Precision Pressure Transmitter pressure ports and process connections with flush welded stainless steel diaphragm accuracy according to IEC 600: 0, % FSO Nominal pressure from 0... 00 mbar up to
More informationPLASTIC SQUARE INDUCTIVE PROXIMITY SENSOR (10-30VDC)
PLASTIC SQUARE INDUCTIVE PROXIMITY SENSOR (-0VDC) Diameter Q8 Q8 Shielded non-shielded Switching Distance, Sn: mm Housing Material With Without 1.5 mm 1.5 mm Picture Dimensions (unit: mm) 8 7. 8 8 0.5.5
More informationRelative pressure transmitter type 520
Relative pressure transmitter type 520 Pressure range The compact type 520 pressure transmitter is based upon the Huba Control developed thick film technology where the pressure measuring cell is fully
More informationED 701 General Industry Pressure Transmitter
ED 701 General Industry Pressure Transmitter Standard industrial process connections Complete range of electrical connections 4... 20 ma and Voltage outputs Accuracy: 0.1%, 0.2% and 0.4% FS Quick response
More informationSurface-mounting Thermostats ATH Type Series
Page 1/9 urface-mounting Thermostats ATH eries k enclosure protection IP 54 k tested to IN EN 14597 (replacing IN 3440) Brief description Thermostats control and monitor thermal processes. Instruments
More informationDS 300. Electronic Pressure Switch. with IO-Link interface. Stainless Steel Sensor. accuracy according to IEC 60770: 0.35 % FSO.
DS 00 Electronic Pressure Switch with IO-Link interface Stainless Steel Sensor accuracy according to IEC 60770: 0.5 % FSO Nominal pressure from 0... 00 mbar up to 0... 600 bar Digital output signal IO-Link
More informationFitting PS P - B - R2
INTERNAL STRUCTURE PS86 (G 3/8) 2 3 FEATURES Solidstate pressure switch with no mechanical moving parts Isolated output via a photo-coupler Switching pressure adjustable and hysteresis band adjustable
More informationDS 200 DS 200 DRUCK & TEMPERATUR LEITENBERGER GMBH. Electronic Pressure Switch. Stainless Steel Sensor. Electronic Pressure Switch
DRUCK & TEMPERATUR LEITENBERGER GMBH DS 00 Electronic Pressure Switch Stainless Steel Sensor accuracy according to IEC 00: standard: 0. % FSO option: 0. % FSO Nominal pressure: from 0... 00 mbar up to
More informationDiameters 4-5 mm Amplified in d.c. 3 wires Cable output
CYLNDRCAL NDUCTVE SENSORS N METAL HOUSNG s Amplifie in.c. wires output A L B L L Thickness M x 0, SW, : m PVC CE ; 90 C; 00 V; O.R. : stainless steel Sensing face: Technical ata: Supply voltage (U B ):
More informationIts modular concept allows to build up a ball valve for any degree of automation and any kind of application
Type 2657...59 DN 10 up to 80 mm; Plastic; 2/2 way dvantages/benefits ntegrated pilot valves, position feed-back and limit switches available Customized system solutions with Burkert valves & sensors With
More informationTHM80X Series Feature Application. Temperature & Humidity / Flow Measuring Specialist
THM80X Series Feature Application IP67 protection degree, rugged aluminum case, fit in variety harsh environment Capable of temperature compensation Linear adjustment temperature & humidity by computer,
More informationPressure transmitters for industrial applications MBS 32 and MBS 33
Data sheet Pressure transmitters for industrial applications MBS 32 and MBS 33 The standard pressure transmitters MBS 32 and MBS 33 are designed for use in almost all industrial applications, and offer
More informationIndustrial Pressure Transmitter
ECT 87 Industrial Pressure Transmitter Swiss based Trafag is a leading international supplier of high quality sensors and monitoring instruments for measurement of and temperature. The economical transmitter
More informationCS Series. Capacitance Type. Type. Proximity Sensor. Features
INFORMATI Series Features Capacitance Type - Metal cylinder/resin cylinder/square type - Non-metal objects such as wood, paper, plastic and water can be detected. - The operating distance is adjustable
More informationImformation of C091D series
Imformation of C09D series The QTY of contacts is -pin to -pin, the connection method for the thread type, pinhole connections for welding type, press-fit and PCB type. This series of connectors to prevent
More informationAbsolute encoders multiturn
elektronischer electronic multiturn, Multiturn, magnetic magnetisch Sendix M66 / M68 (shaft / hollow shaft) The Sendix M6 with Energy Harvesting Technology is an electronic multiturn encoder in miniature
More informationPRODUCT CATALOGUE PREssURE switch
PRODUCT CATALOGUE PREssURE switch w w w. p a a b. c o m Pressure AT THe HIGHesT LeVeL Successful mediumsized companies are not successful because they are active in many areas, but rather because they
More informationIndustrial Pressure Transmitter
ECT 87 Industrial Pressure Transmitter Swiss based Trafag is a leading international supplier of high quality sensors and monitoring instruments for measurement of and temperature. The economical transmitter
More informationPressure Transmitter ED 701
Pressure Transmitter ED 701 Hygienic and industrial process connections Zero setting function Accuracy < 0.1% FS Quick response time < 25 ms High long-term stability Excellent repeatability Active compensation
More informationThermal-Magnetic Circuit Breaker 2210-S2..
Thermal-Magnetic Circuit Breaker -S.. Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 6094/IEC 94). Designed for
More informationS95.3U01 / S95.3U11. Head mounted temperature transmitters, programmable, Pt 100 (RTD), thermocouples, electrical isolation
S95.U0 / S95.U Head mounted temperature transmitters, programmable, Pt 00 (RTD), thermocouples, electrical isolation Resistance thermometer (,, wire circuit) Thermocouples Resistance remote signalling
More informationThermal-Magnetic Circuit Breaker 2210-S2...
Thermal-Magnetic Circuit Breaker 0-S... Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 60934/IEC 934). Designed
More informationThermal-Magnetic Circuit Breaker 2210-S2...
Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 6094/IEC 94). Designed for panel or plug-in mounting. Available
More informationThermal-Magnetic Circuit Breaker 2210-S2..
Thermal-Magnetic Circuit Breaker -S.. Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 60934/IEC 934). Designed for
More informationProximity Sensor Ideal for High Temperatures and Cleaning Processes. Applicable to 120 C
ASH & ALAIN INDIA PVT LTD S-00, F.I.E.E., Okhla Industrial Area, Phase-ii, New Delhi-000(India) Tel : 0-797575 Fax : 0-79757 E-mail : sales@ashalain.com Proximity Ideal for High Temperatures and Cleaning
More informationAmphenol. Amphenol-Tuchel Electronics GmbH. Circular Connectors C 091 A/B/D Series
Amphenol Amphenol-Tuchel Electronics GmbH Circular Connectors C 09 A/B/D Series The Company Amphenol-Tuchel Electronics GmbH is a member of the USA based Amphenol Corporation. With our own global presence
More informationAmphenol Amphenol-Tuchel Electronics GmbH. C 091 A/B/D Series. Circular Connectors.
mphenol mphenol-tuchel Electronics GmbH C 09 //D Series Circular Connectors www.industrial-amphenol.com Note from the CEO Ladies and Gentlemen, For over years mphenol has enjoyed success as the interconnection
More informationThermal-Magnetic Circuit Breaker 2210-S2..
Thermal-Magnetic Circuit Breaker -S.. Description One, two and three pole thermal-magnetic circuit breakers with trip-free mechanism and toggle actuation (S-type TM CBE to EN 60934/IEC 934). Designed for
More informationATEX/IECEx RTD temperature probe
Page 1/8 ATEX/IECEx RTD temperature probe with connecting cable acc. to DIN EN 60751 For temperatures from -100 to +600 C As single, double, or triple RTD temperature probe In two-wire, three-wire, or
More informationDC METAL FACE INDUCTIVE PROXIMITY SWITCH
M M M mm mm mm 0-0VDC/ -VDC / 0- VDC / 0-0VDC
More informationSUBMINIATURE MICROSWITCHES - PREMIUM
0/08 SUBMINIATUE MICOSWITCHES - PEMIUM V - 870 High precision flexible leaf snap-action mechanism Operation without balance-point, even at extremely slow actuating speed atings from ma Vc up to (6) A 0
More informationT20WN. Data Sheet. Torque transducers. Special features. Installation example with bellows couplings. B en
T20WN Torque transducers Data Sheet Special features - Nominal (rated) torques 0.1 N m, 0.2 N m, 0. N m, 1 N m, 2 N m, N m, 10 N m, 20 N m, 0 N m, 100 N m, 200 N m - Accuracy class: 0.2 - Contactless transmission
More informationV 12: Miniature photoelectric switches in M 12 housings
Lichtschranken Photoelectric Baureihe switcheswl 7- Photoelectric proximity switches Photoelectric reflex switches : iniature photoelectric switches in housings Through-beam photoelectric switches They
More informationCALEFFI. Modulating digital controller for heating and cooling. 161 series 01122/08 GB. replaces dp 01122/05
Modulating digital controller for heating and cooling series REGI ERED SI EN ISO 00:000 Cert. n FM UNI EN ISO 00:000 Cert. n 000 0/0 G replaces dp 0/0 Function The controller can be used with three-point
More informationMINIATURE MICROSWITCHES - PREMIUM
0/08 MINIATURE MICROSWITCHES - PREMIUM V - 86 High precision flexible leaf snap-action mechanism Operation without balance-point, even at extremely slow actuating speed Broad range of operating forces
More informationMINIATURE MICROSWITCHES - PREMIUM
0/06 MINIATURE MICROSWITCHES - PREMIUM V - 86 High precision flexible leaf snap-action mechanism Operation without balance-point, even at extremely slow actuating speed Broad range of operating forces
More informationHydraulic Pressure NAH Applications. Features. New generation available - refer to
NAH 8 Hydraulic Pressure Transmitter New generation available - refer to www.trafag.com/h70 Swiss based Trafag is a leading international supplier of high quality sensors and monitoring instruments for
More informationTable of Contents SC Series Features and Benefits
Table of Contents SC Series...................................................... -6 Features and Benefits.................................................................................. How To Order........................................................................................
More informationLinear measuring technology
Their extremely robust construction, their high IP69k protection level and their wide temperature range make these new draw wire encoders particularly reliable and durable. Their flexibility and adaptability
More informationDifferential Pressure Switch
Features Using piezoresistive pressure sensor, which is compensated and aged well; high accuracy, quick response; Amplifier circuit driving switch relay; relay value could be set freely between zero and
More informationSCTP20 Programmable 2-Wire Temperature Transmitter, Head Mount
20 Programmable 2-Wire Temperature Transmitter, Head Mount Configurable Transmitters Description Each 20 2-wire transmitter is designed for measuring temperature using thermocouples or RTDs. The input
More informationMagnetic and Hydraulic-Magnetic Circuit Breaker 8340-T...
Magnetic and Hydraulic-Magnetic Circuit Breaker 830-T... Description ngle, two and three pole magnetic and hydraulic-magnetic circuit breakers with trip-free mechanism and toggle actuation. A choice of
More informationAmphenol C 091 A/B/D. Circular Connectors. Amphenol-Tuchel Electronics GmbH
Amphenol C 091 A/B/D Circular Connectors Amphenol-Tuchel Electronics GmbH General information These connectors are designed and produced in conformity with the low-voltage directive (/3/EWG) respectively
More informationCDS. high density spring connection
CDS high density spring connection DENSTY STANDARD 1A CDS DENSTY A A spring connection CDS Series The originality of multipole connectors represents one of the core values of LE, a leading company in this
More informationSafety Barriers Series 9001, 9002 Standard Applications
Standard s Analog input with transmitter Smart 9001/51-80-091-141 09949E0 Load of transmitter U N = + 0 V... 35 V I N = 3.6 ma... ma R L ( 350 O U min (I N= 0 ma) U N - 9.5 V 14 V U N ( 3.5 V > 3.5 V Maximum
More informationConductivity sensor for hygienic applications
Conductivity sensor for hygienic applications Type 8221 can be combined with Perfect for demanding applications in the hygienic industry (CIP and SIP compatible) Variants available for usage over a wide
More informationEX-EMERGENCY LIGHT FITTINGS
EX-EMERGENCY LIGHT FITTINGS nllk 0...N 1-36 W Plastic version for Zone 2 and Zone 21/22 The explosion-protected light fittings of the series nllk 0 N are conform to the requirements of the ATEX-Directive
More informationTechnical specification FLUXUS F502TE
Technical specification FLUXUS F502TE Permanently installed and non-invasive ultrasonic flowmeter for the measurement of thermal energy and volumetric flow rate Precise and intelligent energy measuring
More informationI nllk 08018/18 I nllk I nllk 08036/36 I nllk I I nllk 08058/58 I
I nllk / I x W x W x W x W x W Technical data Cooper Crouse-Hinds - all rights reserved nllk / nllk nllk / nllk nllk / Marking to //EC II G Ex na II T / II D td A IP T C EC Conformity Statement PTB ATEX
More informationAIR PREPARATION. ELECTRONICALLY CONTROLLED PRESSURE REGULATING VALVE (PROPORTIONAL PRESSURE REGULATING VALVE) SERIES control
AIR PREPARATION ELECTRONICALLY CONTROLLED PRESSRE REGLATING ALE (PROPORTIONAL PRESSRE REGLATING ALE) SERIES control Description Abb. Port size Recommended Type Data Sheet No. flow (l/min)* airfit tecno
More informationField IT 50T Series Transmitters
Data Sheet SS/G/A_ Field IT 0T Series Transmitters gauge/absolute pressure transmitter Ranges: -00 to 0000kPa - to 00bar -. to 6000psi Base accuracy : 0.% (BFSL) Chemical Vapour Deposition (CVD) technology
More informationPhoto-electric sensors1
References Three-wire DC, solid-state output Teach mode - + Sensing distance (Sn) m Depending on Function Output Connection Reference Weight NO/NC Prograable PNP Pre-cabled XUDAPSML 0.00 M XUDAPSMM 0.00
More information2/2-way ball valve with electric rotary actuator, ball valve in plastic, DN 10-50
/way ball valve with electric rotary actuator, ball valve in plastic, N 50 Suitable for aggressive media High flow rate value Actuator with adjustable limit switches Visual position indicator Type 0 can
More informationRoHS. Versatile. X g. X 2 e
s IN8, - and The inclinometers of the IN8 series allow measuring inclinations in the range of ±85 or -dimensional inclinations up to 0. With their high robustness, their protection level up to max. IP9k
More informationmicroswitches Low force
0/06 Subminiature MICOSWITCHES - PEMIUM V - 870 High precision flexible leaf snap-action mechanism Operation without balance-point, even at extremely slow actuating speed atings from ma Vc up to (6) A
More informationOperating Instructions for Digital Manometer. Model: MAN-SD
Operating Instructions for Digital Manometer Model: MAN-SD 1. Contents 1. Contents...2 2. Note...3 3. Instrument Inspection...3 4. Regulation Use...4 5. Operating Principle...4 6. Mechanical Connection...5
More informationPermanently installed and non-invasive ultrasonic flowmeter for the measurement of thermal energy and volumetric flow rate
Technical specification FLUXUS F502TE Permanently installed and non-invasive ultrasonic flowmeter for the measurement of thermal energy and volumetric flow rate Stationary ultrasonic clamp-on system for
More informationVISUAL LEVEL INDICATORS
VIUL LEVEL INDICTOR LV... The level indicators series is available for both static and mobile applications; the construction materials used make it possible to guarantee service with wide temperature variations
More informationCompact and low-cost monitoring of conductive liquids. Magnetic-inductive flow metering from ifm.
Flow sensors www.ifm.com/mid Compact and low-cost monitoring of conductive liquids. Magnetic-inductive flow metering from ifm. For industrial applications Volumetric flow sensor efector mid. High-precision
More informationMilitary Qualified 10AT Series Snap Action Precision Position Switches
Military Qualified 10AT Series Snap Action Precision Position Switches FEATURES Stainless steel, hermetic seal construction Rated up to 4 amps, 30VDC MIL-PRF-8805 qualified Various mounting configurations
More informationTF 202 / TF 202-Ex. Field mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels
TF 0 / TF 0-Ex Field mounted temperature transmitters, FOUNDATION Fieldbus (H), Pt 00 (RTD), thermocouples, or independent channels 0/-8.69 EN USA Input Resistance thermometer (,, wire circuit) Thermocouples
More informationUniversal limit switches
SWITCHES.CROUZET.COM 1 LIMIT SWITCHES 0/016 Universal limit switches 8384 standard 8384 with positive break operation Conformity to standards IEC / EN 60947--1, including Annex K for version with positive
More informationct m ive p 5/EC Thermal cut-outs
RoHS Compliant Directive //EC Marking of switches type: AM, AF, AB,, AA. AM0. 0. 0 0/0 -. 0 Strip length Second conductor length First conductor length Type of thermal cut-out Rated switching temperature
More informationSINEAX VK 636 Programmable Temperature Transmitter with PROFIBUS-PA protocol
with PROFIBUS-PA procol for installation in the terminal head of a temperature sensor DIN 79, shape B Application 00 II () G FISCO The SINEAX VK 66 is a temperature transducer for use in aumation systems
More informationAT SERIES OFF CIRCUIT TAP CHANGERS
T SERIES OFF CIRCUIT TP CHNGERS THE CHOICE COE S.P.. PUTS ON THE RKET THE NEW T SERIES OFF CIRCUIT TP CHNGERS. T COE: THE CHOICE Comem S.p.. makes use of four main characteristics in order to be successful
More informationSales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,
E X - L I G H T F I T T I N G S nllk 0... 1 - W All-plastic design for Zone 2 and Zone 21/22 The explosion-protected light fittings of the series nllk 0 conform to the requirements of the ATEX-Directive
More informationINFORMATION TECHNOLOGY SYSTEMS SPDs FOR 19 TECHNOLOGY. NET Protector Surge Arrester. Protects switches, HUBs and telecommunication
Surge Arrester Protects switches, HUBs and telecommunication systems Class D according to EN 0 possible (Gigabit Ethernet) Variably equippable patch panels Units available with plug-in inputs and outputs
More information2.12. Ex-Linear light fittings for fluorescent lamps - max. ambient temperature + 60 C - nllk W - 58 W for Zone 2 and 22
.1 Ex-Linear light fittings for fluorescent lamps - max. ambient temperature + C - nllk 09 18 W - 58 W for Zone and The lighting solution for high temperatures up to C The linear luminaires series nllk
More informationDirect-operated 2/2-way solenoid valves Type EV210B
Data sheet Direct-operated 2/2-way solenoid valves Type EV20B EV20B covers a wide range of direct-operated 2/2-way solenoid valves for universal use. EV20B is a very robust valve program with high performance
More informationLD-LP-LL-LC Rope Safety Switches with reset for emergency stop
TECHNICA DATASHEET D-P--C Rope Safety Switches with reset for emergency stop Metal or polymer housing, from one or three conduit entries Protection degree IP6 In conformity with EN ISO 13850 contact blocks
More informationPressure Measurement. Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level 2/27
Overview Siemens AG 011 Function s are for measuring the liquid levels in wells, tanks, channels and dams. Diaphragm p Sensor U const. U + (brown) I EM I -1 (blue) 0, U B s are submersible sensors for
More informationCartridge Valves Technical Information. Quick reference
Quick reference Contents CPF0... 8. CP600-5... 8. CP60-5... 8. 066 handle kit... 8.5 MP06... 8.6 MP... 8.6 X05-FD0 Traction manifold... 8.9 X05-FD6 Traction manifold... 8.0 X05-FD0 Traction manifold...
More informationWT 27 L-2 Laser Photoelectric proximity switches, background suppression -- DC. Dimensional drawing Adjustments possible WT 27L-2F 430
WT L- Laser Photoelectric proximity switches, background suppression -- DC 00...00 mm Photoelectric proximity switches Dimensional drawing.. Laser LED, red light Adjustable background suppression 0 0.
More informationK04 TYPE -40 C +85 C 20000H
K04 TYPE -40 C +85 C 20000H Extended life. Surge-proof capacitor in aluminium can with insulation sleeve. To be mounted with ring clips or with threaded stud. Designed for high resistances to voltage spikes.
More informationAmphenol. Amphenol-Tuchel Electronics GmbH. Series C 146 Heavy Duty Connectors Core Programme
Amphenol Amphenol-Tuchel Electronics GmbH Series C 146 Heavy Duty Connectors Core Programme The Company General information These connectors are designed and produced in conformity with the voltage directive
More informationCooling Water Flow Regulator
Temperature controlled, indirectly and directly actuated diaphragm valves / seat valves Port size G 3/8 to G DN 0 to DN 0 ontinuous regulation High accuracy No auxiliary energy required Technical data
More informationZ7A. Load cells. Special features. Data sheet. Wiring code
Z7A Load cells Special features - Complies with OIML R60 regulations up to 3000 d - Max. capacities: 500 kg... 10 t - Fulfills EMC requirements in accordance to EN 45 501 - Low transducer height - Robust
More informationSilicon Temperature Sensors KT 100 KT 110 KT 130 KT 210 KT 230. KTY 11-x KTY 13-x KTY 21-x KTY 23-x KTY 19-6 KTY 16-6
Silicon Temperature Sensors KT 100 KT 110 KT 130 KT 210 KT 230 KTY 16-6 KTY 10-x KTY 11-x KTY 13-x KTY 21-x KTY 23-x KTY 19-6 Features Temperature dependent resistor with positive temperature coefficient
More informationø6, ø10, ø15, ø20, ø25, ø32, ø40, ø50, ø63 How to Order Switch rail Nil Standard stroke Refer to page 12 for standard stroke.
Magnetically Coupled Rodless Cylinder: Direct Mount ype Series ø, ø, ø, ø, ø, ø, ø, ø0, ø Direct mount type mm mm mm mm mm mm mm 0 0 mm mm 00 MB Piping type Both sides piping type Centralized piping type
More informationAUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY HAH1BVW S/08
AUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY HAH1BVW S/08 Introduction The HAH1BVW family is for the electronic measurement of DC, AC or pulsed currents in high power and low voltage automotive applications
More informationHYGRASGARD KFF KFTF HYGRASGARD AFF AFTF HYGRASGARD AFF - LC AFTF - LC
HYGRASGARD AFF - LC AFTF - LC sensors, calibrateable, with and active passive output Quality product for HVAC sector, accuracy % r.h. The calibrateable room humidity and temperature sensor HYGRASGARD KFF
More informationMetal oil filler and air breather filler caps. Bayonet connection. Reservoir holes. TA46 B (Materials)
Metal oil filler and air Series T 46 4 5 6 4 ayonet connection Ø 46 7 8 46 Reservoir holes T46 (Materials) M5 - Cover: Chrome Plated Steel - Filter element: Impregnated paper Polyurethane 64-6 - Flange:
More informationSUBMINIATURE MICROSWITCHES - STANDARD
0/08 SUBMINIATURE MICROSWITCHES - STANDARD VD - 87 Flexible leaf snap-action mechanism with wiping contacts Ratings from 0.0 A Vc to (6) A 0 Va and / hp -0 Va ENEC and curus approved up to +0 C Housing
More informationTransmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level
Overview Function s are for measuring the liquid levels in wells, tanks, channels and dams. Sensor Diaphragm p U const. U +2 (brown) I EM I - (blue) 0, U B s are submersible sensors for hydrostatic level
More informationExplosion-protected recessed ceiling LED-light and fluorescent light fittings
.7 Explosion-protected recessed ceiling LED-light and fluorescent light fittings LED 600, RLF LED 100 and self-contained emergency luminaire RLF LED 600 N, RLF LED 100 N RLF/RLF-INOX 50 18-58 W / RLF/RLF-INOX
More informationFLOW SENSOR FOR LIQUID MEDIA Serie 210
FLOW SENSOR FOR LIQUID MEDIA Serie 0 Flow range 0.... 0 l/min Nominal diameters DN 6 / 8 / 0 / / 0 / Temperature measurement -0... + ÀC In comparison to the OEM flow sensor (type 00), the type 0 is available
More informationSurface-mounting thermostats Series ATH
JUMO GmbH & Co. KG Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 E-mail: mail@jumo.net Internet: www.jumo.net
More informationS95.3U02 / S95.3U12. Head mounted temperature transmitters, HART programmable, Pt 100 (RTD), thermocouples, electrical isolation
S95.U0 / S95.U Head mounted temperature transmitters, HART programmable, Pt 00 (RTD), thermocouples, electrical isolation Resistance thermometer (,, wire circuit) Thermocouples Resistance remote signalling
More informationThermal-Magnetic Circuit Breaker 2210-T2...
Thermal-Magnetic Circuit Breaker 0-T... Description One, two and three pole thermal-magnetic circuit breakers with trip-free mechanism and toggle actuation (S-type TM CBE to EN 6094/IEC 94). Featuring
More informationDirect-operated 2/2-way compact solenoid valves Type EV210A
Data sheet Direct-operated 2/2-way compact solenoid valves Type EV210A EV210A covers a wide range of small, directoperated 2/2-way solenoid valves for use in industrial machinery. The compact design together
More informationISEmax CAM40/CAS40. Technical Information
Technical Information Online measurement of nutrient parameters Ion-selective electrode system for the continuous measurement of ammonium and nitrate Application The ion-selective electrode system works
More information