1 FLOW SENSOR FOR LIQUID MEDIA Serie 0 Flow range l/min Nominal diameters DN 6 / 8 / 0 / / 0 / Temperature measurement ÀC In comparison to the OEM flow sensor (type 00), the type 0 is available with an increased range of power supply and output signals all with and without temperature measurement. With no moving parts the flow sensor is not sensitive to debris, has marginal pressure loss and high accuracy. Flow measuring with voltage, current or frequency output Temperature non-sensitive measuring principle Excellent media resistance (measuring element not in contact with the media) CE conformity Wide application temperature range Marginal loss of pressure Measuring element not sensitive to debris Direct temperature measurement in the medium Drinking water approval KTW, W70, WRAS

2 Technical overview Flow measurement Measuring principle Vortex Piezoelectric sensor element Measuring range l/min Nominal diameters DN 6 / 8 / 0 / / 0 / Accuracy at < 0% fs (water) < % fs Accuracy at > 0% fs (water) < % measuring value Response time Immediately Signal delay < 00 ms Frequency output Therefore suitable for spigot use. Response time < ms Signal delay < s Analogue output Response time < 00 ms Temperature measurement (> 8 DN - DN 6 on request) Measuring principle Resistance PT000 Measuring range ÀC T = 0 ÀC μ 0. K Accuracy class B D EN T 0 ÀC μ 0. K μ 0.00 * T Measuring range ÀC Accuracy μ 0. K μ 0.00 * T V T (ÀC) = +0 ÀC Calculation temperature 0 V * UOUT_T - ÀC Temperature influences Self-heating at temperature sensor K/mW Conduction resistance to connector 0.8 Ohm Operating conditions Medium Suitable for heating circuit water with the usual additives Drinking water Other medium on request Media < + ÀC Temperature Ambient ÀC Storage ÀC (for lifetime) bar at +0 ÀC (for lifetime) 6 bar at +00 ÀC Max. pressure and (for 600 hours) bar at + ÀC medium temperature (for hours) bar at +0 ÀC (max. test pressure) 8 bar at +0 ÀC Cavitation The following equation is valid to prevent cavitation: P abs outlet / P difference >. Materials in contact with medium (FDA-conform) Sensor paddle Case with damming body Sealing material ETFE PA6T/6I (0% GF) EPDM (perox.) Electrical overview Frequency output Voltage output Current output Power supply U.7... VDC.... VDC 8... VDC Output Frequency square pulse signal UOUT_Q_frequency < > U - 0. V Flow (Q) Analogue signal U OUT_Q oder I OUT V... 0 ma Output Resistant signal R OUT PT000 PT000 class B D EN 607 temperature (T) Voltage signal U OUT_T V Electrical connection and protection class Mx (IP 6) Mx (IP 6) Mx (IP 6) Load agianst or < ma / < 00 nf < 6 ma / < 00 nf ) < (U - 8 V) / 0 ma Current consumption load free (I ) < ma < ma Weight DN 6 / 8 DN 0 DN DN 0 DN ~ 7 g ~ 7 g ~ 68 g ~ 9 g ~ 00 g Test / Admissions Drinking water approval KTW / W70 / WRAS Electromagnetic compatibility CE conformity acc. to EN 66-- Packaging (multiple packaging) Connection copper tube Outside thread K Outside thread G DN 6 Blister 0x Blsiter 0x DN 8 / 0 Blister 0x Blister 0x Blister 0x DN Blister 0x Blister 0x Blister 0x DN 0 Blister 0x Blister 0x Blister x DN Blister x Blister x ) against only ) incl. xdi inlet and outlet side ) Pv in Pa; Q in l/min

3 Nominal diameters dependent variables Nominal diameters DN 6 Connection Outside thread heavy Measuring range Quantity per puls Flow range Characteristic line frequency output Frequency range Characteristic line voltage outout Characteristic line current output Pressure drop ), ) l/min 0.86 ml m/s 0.08 * f Hz Q =.0 * U OUT_Q Q = 0.6 * (l - ma) 0 * Q 0.68 ml * f Hz DN 8 Outside thread heavy l/min 0.6 ml m/s 0.09 * f Hz Connection copper tube 0.6 ml 0.08 * f Hz Q =. * U OUT_Q Q = 0.98 * (l - ma) 8.00 * Q.99 ml * f Hz DN 0 Outside thread heavy.8... l/min.70 ml m/s 0.08 * f Hz Connection copper tube.8 ml 0.08 * f Hz Q =. * U OUT_Q Q =.000 * (l - ma).0 * Q.0 ml * f Hz DN 0 Outside thread heavy l/min.7 ml m/s 0.08 * f Hz Connection copper tube.88 ml 0.08 * f Hz Q =.0 * U OUT_Q Q =.00 * (l - ma).0 * Q.07 ml 0.8 * f Hz DN Outside thread heavy l/min.06 ml m/s 0.8 * f Hz Connection copper tube.077 ml 0.86 * f Hz Q =.0 * U OUT_Q Q =. * (l - ma) 6.70* Q 6. ml 0.7 * f Hz DN 0 Outside thread heavy l/min 6. ml m/s 0.70 * f Hz Connection copper tube 6.08 ml 0.7 * f Hz Q = 8. * U OUT_Q Q =. * (l - ma).0 * Q DN. ml * f Hz l/min m/s Outside thread heavy. ml * f Hz Q = * U OUT_Q Q = 9.7 * (l - ma) 0.9 * Q Minimum life span on high flow rate and high temperature Temperature in ÀC Temperatur in C Durchfluss Flow in % in % Std hours 0 hours Std 00 hours Std 0. year Jahr Jahr year 0 year Jahre ) incl. xdi inlet and outlet side ) Pv in Pa; Q in l/min

4 Order code selection table 0. X X X X X X X Version Flow 9 Flow and temperature (PT000) 8 Flow and temperature ( V) 6 Nominal diameters and DN l/min K,G flow range DN l/min. 0 8 DN l/min. 0 DN l/min. DN l/min. DN l/min. 0 DN l/min. K,G Output / power supply Frequency output (Square pulse signal).7... VDC 8,9 Analogue signal V.... VDC Analogue signal... 0 ma 8... VDC 8,9 Electrical connection Connector Mx - or -pole (condensation protection) 9 Connector Mx - or -pole (condensation protection) 8,6 Sealing material EPDM Ethylene propylene rubber (peroxidically cross-linked) Tube connection Plastic PA6T / 6I connection copper tube (max. DN 0) N Plastic PA6T / 6I outside thread K (see dimension diagram) K Plastic PA6T / 6I outside thread G (see dimension diagram) G Accessories ) Order number Connection kit ) DN 8, 0 with copper tube 77 Connection kit ) DN 8, 0 with adapter Rp ⅜ Stainless steel.0/aisi Connection kit ) DN with copper tube 777 Connection kit ) DN with adapter Rp ½ Stainless steel.0/aisi Connection kit ) DN 0 with copper tube 779 Connection kit ) DN 0 with adapter Rp ¾ Stainless steel.0/aisi Straight-wire box for connector Mx with cable -pole 00 cm 60 Corner-wire box for connector Mx with cable -pole 00 cm 60 Straight-wire box for connector Mx with cable -pole 00 cm (with temperature) 6 Corner-wire box for connector Mx with cable -pole 00 cm (with temperature) 6 Straight-wire box for connector Mx screwing terminal -pole 0 Clip for DN 8,0 6 Clip for DN 09 Clip for DN 0 O-Ring for DN 8, DN 0 EPDM Œ.9 x.6 Copper tube and adapter O-Ring for DN EPDM Œ 7.86 x.6 Copper tube and adapter 6 O-Ring for DN 0 EPDM Œ.89 x.6 Copper tube and adapter 7 O-Ring for DN EPDM Œ x (as a replacement, already assembled) 79 Connection copper tube for DN 8, 0 L=0 mm Connection copper tube for DN L=0 mm Connection copper tube for DN 0 L=0 mm 06 Adapter for DN 8 und DN 0 Rp ⅜ Stainless steel.0/aisi 0 6 Adapter for DN Rp ½ Stainless steel.0/aisi Adapter for DN 0 Rp ¾ Stainless steel.0/aisi 0 66 ) Accessories supplied loose ) Connection set includes: x Clip, x Copper tubes or Adapter and x O-Ring

5 Dimension diagram DN 6, 8, 0,, 0, d 6d d d d d d d d d d 6d DN6 K.7.0 G ½ 77 DN6 G 8..7 G ¾ 86 DN8 K.7.0 G ½ 77 d DN8 G 8..7 G ¾ 86 DN0 K.0. G ½ 8 9 DN0 G 9.. G ¾ 90 9 DN K G ¾ 87 6 DN G.6 9. G 97 6 DN0 K G DN0 G G ¼ DN K G ¼ 0 6 DN G G ½ 6 Dimension diagram DN 8, 0,, 0 a a a a a a a a a a 6a 6a DN DN DN DN

6 Admissible locking torque DN6/8/0 G ½ DN6/8/0 G ¾ DN G ¾ DN G DN0 G DN0 G ¼ DN G ¼ DN G ½ M min [Nm]... M max [Nm] Accessories DN 8, 0,, 0 adapter.0 c inside thread clip c o-ring to adapter c c 7c 6c c 8c 9c c c c c c 6c 7c 8c 9c DN8 DN0 DN DN0 0 Rp ⅜ D 999 lenght min. 9 Rp ⅜ D 999 lenght min. 9 Rp ½ D 999 length min.. Rp ¾ D 999 lenght min Geometry of customers connection tube DN 8, 0,, 0 o-ring b clip 6b b b bevelled edge min. 0. b 7b b 8b 9b b b b b b 6b 7b 8b 9b DN8 Œ.9x6 μ μ 0. Œ μ 0. Œ.00 μ 0.08 Œ 8.88 μ DN0 Œ.9x6 μ μ 0. Œ μ0. Œ.00 μ 0.08 Œ 8.88 μ DN DN0 Œ 7.86x.6 μ μ 0. Œ 6 μ 0. Œ Œ.89x.6 μ 0..9 μ 0. Œ 0 μ 0. Œ Œ.8 μ Œ.8 μ

7 Tube mounting instructions Consider the following to ensure the correct function of the sensor. Only diameter changes from large to small are allowed. Avoid repeated elbows in the same level at entryside minimum xdn for alternative elbows minimum 0.xDN for recommended 90À elbow with min. R.8xDN Electrical connection Connector Mx without temperature measurement OUT Hz Frequency output current output A V OUT voltage output OUT Q Pin Colour brown blue black brown white blue black gray Connector Mx with temperature measurement A T Ω T Hz T Ω T T Ω T OUT OUT Q V OUT T OUT Q V V frequency output with PT000 current output with PT000 voltage output with PT000 voltage output with temperature output V

8 Influence of glycol With the following definitions we are able to correct the influence of media with higher viscosity than water (= media viscosity >.8 cst) in order to reach a measuring accuracy of % fs in the range of.8 - cst and of % in the range of - cst ( = viscosity in cst). Definition of viscosity of glycol-water-compound Kinematic Kinematische Viskosität Ethylenglykol Wasser viscosity ethylene glycol water Kinematic Kinematische Viskosität Propylenglykol Wasser viscosity propylene glycol water Temperature Temperatur in C ÀC % 0% 0% 0% 0% 0% 60% 70% Temperature Temperatur in C ÀC % 0% 0% 0% 0% 0% 60% viscosity Viskosität in cst in viscosity Viskosität in cst in Definition of respond threshold Q min Definition of characteristic line formula Q = k * f - Q 0 Minimal detektierbarer Durchfluss detectable flow Einfluss der Viskosität auf Q Influence on viscocity Q0 0 Minimaler Durchfluss in l/min flow l/min 0 0 DN0 DN DN0 DN characteristic Q0 in Kennlinienformel in l/min line formula DN0 DN DN0 DN viscosity Viskosität in cst in viscosity Viskosität in cst in Formula respond threshold Q min in l/min < DN 0 not possible DN 0: Q min = υ DN : Q min = υ +. DN 0: Q min = υ +.0 DN : Q min = υ Formula characteristic line for Q > Q min in l/min < DN 0 not possible Frequency output: DN0: Q = 0.08 * f 0.0υ DN: Q = 0.8 * f 0.υ + 0. DN0: Q = 0.7 * f 0.υ + 0. DN: Q = * f 0.80υ Voltage output V DN0: Q =. * UOut 0.0υ DN: Q =.0 * UOut 0.υ + 0. DN0: Q = 8. * UOut 0.υ + 0. DN: Q =.0 * UOut 0.80υ Current output... 0 ma (I in ma) DN0: Q =.000 * (I ma) - 0.0υ DN: Q =. * (I ma) - 0.υ + 0. DN0: Q =. * (I ma) - 0.υ + 0. DN: Q = 9.7 * (I ma) υ

Flow sensor for liquid media type 210

Flow sensor for liquid media type 210 Flow sensor for liquid media type 0 Flow range 0.... 0 l/min Nominal diameters DN 6 / 8 / 0 / / 0 / Temperature measurement -0... + ÀC In comparison to the OEM flow sensor (type 00), the type 0 is available

More information

Flow sensor for liquid media type 230

Flow sensor for liquid media type 230 Flow sensor for liquid media type 0 Flow range.8... 0 l/min Nominal diameters DN 0 / / 0 / Temperature measurement -0... + ÀC The flow sensor type 0 is based on the Kármán vortex trail. You can choose

More information

OEM Flow sensor for liquid media type 200

OEM Flow sensor for liquid media type 200 OEM Flow sensor for liquid media type 200 Flow range 0.5... 150 l/min Nominal diameters DN 6 / 8 / 10 / 15 / 20 / 25 Temperature measurement -40... +125 ÀC The flow sensor type 200 is based on the Kármán

More information

OEM Flow sensor for liquid media type 200

OEM Flow sensor for liquid media type 200 OEM Flow sensor for liquid media type 200 Flow range 0.9... 150 l/min Nominal diameters DN 8 / 10 / 15 / 20 / 25 Temperature measurement -40... +125 ÀC The flow sensor type 200 is based on the Kármán vortex

More information

OEM Flow sensor for liquid media type 200

OEM Flow sensor for liquid media type 200 OEM Flow sensor for liquid media type 200 Flow range 0.5... 150 l/min Nominal diameters DN 6 / 8 / 10 / 15 / 20 / 25 Temperature measurement -40... +125 ÀC The flow sensor type 200 is based on the ármán

More information

OEM Flow sensor type 235 for liquid media

OEM Flow sensor type 235 for liquid media OEM Flow sensor type 235 for liquid media Flow range 0.9... 240 l/min Nominal diameters DN 8 / 10 / 15 / 20 / 25 / 32 Temperature measurement -40... +125 ÀC The type 235 is based on the type 200 but incorporates

More information

Flow sensor type 236 for liquid media

Flow sensor type 236 for liquid media Flow sensor type 6 for liquid media Flow range 0.9... 0 l/min Nominal diameters DN 8 / 0 / / 0 / / Temperature measurement -0... + ÀC The type 6 is based on the type 0 but incorporates a brass housing.

More information

Pressure transmitters for industrial applications MBS 32 and MBS 33

Pressure transmitters for industrial applications MBS 32 and MBS 33 Data sheet Pressure transmitters for industrial applications MBS 32 and MBS 33 The standard pressure transmitters MBS 32 and MBS 33 are designed for use in almost all industrial applications, and offer

More information

Relative pressure transmitter type 520

Relative pressure transmitter type 520 Relative pressure transmitter type 520 Pressure range The compact type 520 pressure transmitter is based upon the Huba Control developed thick film technology where the pressure measuring cell is fully

More information

ED 701 General Industry Pressure Transmitter

ED 701 General Industry Pressure Transmitter ED 701 General Industry Pressure Transmitter Standard industrial process connections Complete range of electrical connections 4... 20 ma and Voltage outputs Accuracy: 0.1%, 0.2% and 0.4% FS Quick response

More information

Conductivity sensor for hygienic applications

Conductivity sensor for hygienic applications Conductivity sensor for hygienic applications Type 8221 can be combined with Perfect for demanding applications in the hygienic industry (CIP and SIP compatible) Variants available for usage over a wide

More information

Direct-operated 2/2-way compact solenoid valves Type EV210A

Direct-operated 2/2-way compact solenoid valves Type EV210A Data sheet Direct-operated 2/2-way compact solenoid valves Type EV210A EV210A covers a wide range of small, directoperated 2/2-way solenoid valves for use in industrial machinery. The compact design together

More information

Industrial Pressure Transmitter

Industrial Pressure Transmitter ECT 87 Industrial Pressure Transmitter Swiss based Trafag is a leading international supplier of high quality sensors and monitoring instruments for measurement of and temperature. The economical transmitter

More information

Direct-operated 2/2-way solenoid valves Type EV210B

Direct-operated 2/2-way solenoid valves Type EV210B Data sheet Direct-operated 2/2-way solenoid valves Type EV20B EV20B covers a wide range of direct-operated 2/2-way solenoid valves for universal use. EV20B is a very robust valve program with high performance

More information

Industrial Pressure Transmitter

Industrial Pressure Transmitter ECT 87 Industrial Pressure Transmitter Swiss based Trafag is a leading international supplier of high quality sensors and monitoring instruments for measurement of and temperature. The economical transmitter

More information

DS 200P. Electronic Pressure Switch. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

DS 200P. Electronic Pressure Switch. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm accuracy according to IEC 600: standard: 0. % FSO option: 0. % FSO Nominal pressure from 0... 00 mbar up to 0... 0 bar

More information

Solenoid valves 2/2-way direct-operated type EV210A

Solenoid valves 2/2-way direct-operated type EV210A MAKING MODERN LIVING POSSIBLE Data sheet Solenoid valves 2/2-way direct-operated type EV210A EV210A covers a wide range of small, direct-operated 2/2-way solenoid valves for use in industrial machinery.

More information

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor DMP Industrial Pressure Transmitter for Low Pressure Stainless Steel Sensor accuracy according to IEC 60770: : 0.5 % FSO option: 0.5 / 0. % FSO Nominal pressure from 0... 00 mbar up to 0... 60 bar Output

More information

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm DMP P Industrial Pressure Transmitter Process Connections With Flush Welded Stainless Steel accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 % FSO Nominal pressure from 0... 00 mbar up

More information

AIR PREPARATION. ELECTRONICALLY CONTROLLED PRESSURE REGULATING VALVE (PROPORTIONAL PRESSURE REGULATING VALVE) SERIES control

AIR PREPARATION. ELECTRONICALLY CONTROLLED PRESSURE REGULATING VALVE (PROPORTIONAL PRESSURE REGULATING VALVE) SERIES control AIR PREPARATION ELECTRONICALLY CONTROLLED PRESSRE REGLATING ALE (PROPORTIONAL PRESSRE REGLATING ALE) SERIES control Description Abb. Port size Recommended Type Data Sheet No. flow (l/min)* airfit tecno

More information

Hydraulic Pressure NAH Applications. Features. New generation available - refer to

Hydraulic Pressure NAH Applications. Features. New generation available - refer to NAH 8 Hydraulic Pressure Transmitter New generation available - refer to www.trafag.com/h70 Swiss based Trafag is a leading international supplier of high quality sensors and monitoring instruments for

More information

Pressure Measurement. Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level 2/27

Pressure Measurement. Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level 2/27 Overview Siemens AG 011 Function s are for measuring the liquid levels in wells, tanks, channels and dams. Diaphragm p Sensor U const. U + (brown) I EM I -1 (blue) 0, U B s are submersible sensors for

More information

DS 300. Electronic Pressure Switch. with IO-Link interface. Stainless Steel Sensor. accuracy according to IEC 60770: 0.35 % FSO.

DS 300. Electronic Pressure Switch. with IO-Link interface. Stainless Steel Sensor. accuracy according to IEC 60770: 0.35 % FSO. DS 00 Electronic Pressure Switch with IO-Link interface Stainless Steel Sensor accuracy according to IEC 60770: 0.5 % FSO Nominal pressure from 0... 00 mbar up to 0... 600 bar Digital output signal IO-Link

More information

E8EB-N0C2B E8EB-N0B2B

E8EB-N0C2B E8EB-N0B2B Slim Sensor CSM DS_E 1 Ideal for Workpiece Position and Original Checking The to 1 kpa model can be used for workpiece position checking. The to 1MPa model is ideal for original pressure checking. Degree

More information

Linear measuring technology

Linear measuring technology Their extremely robust construction, their high IP69k protection level and their wide temperature range make these new draw wire encoders particularly reliable and durable. Their flexibility and adaptability

More information

Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level

Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level Overview Function s are for measuring the liquid levels in wells, tanks, channels and dams. Sensor Diaphragm p U const. U +2 (brown) I EM I - (blue) 0, U B s are submersible sensors for hydrostatic level

More information

RoHS. Versatile. X g. X 2 e

RoHS. Versatile. X g. X 2 e s IN8, - and The inclinometers of the IN8 series allow measuring inclinations in the range of ±85 or -dimensional inclinations up to 0. With their high robustness, their protection level up to max. IP9k

More information

Pressure Measurement Single-range transmitters for general applications

Pressure Measurement Single-range transmitters for general applications Siemens AG 07 Overview Function SITRANS LH00 Transmitter for hydrostatic level U const. p U I EM Sensor Connection for auxiliary power supply Vent pipe with humidity filter Protective conductor connection/

More information

TF 202 / TF 202-Ex. Field mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels

TF 202 / TF 202-Ex. Field mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels TF 0 / TF 0-Ex Field mounted temperature transmitters, FOUNDATION Fieldbus (H), Pt 00 (RTD), thermocouples, or independent channels 0/-8.69 EN USA Input Resistance thermometer (,, wire circuit) Thermocouples

More information

VDN2.. VEN2.. VUN2.. Radiator valves. Building Technologies HVAC Products ACVATIX TM. NF norm, for 2-pipe heating systems

VDN2.. VEN2.. VUN2.. Radiator valves. Building Technologies HVAC Products ACVATIX TM. NF norm, for 2-pipe heating systems 06 EN - Straight valves VDN.. Angle valves VEN.. Reverse angle valves VUN.. ACVATIX TM Radiator valves NF norm, for -pipe heating systems VDN.. VEN.. VUN.. Valve bodies made of brass, mat nickel-plated

More information

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm DMP Pi Precision Pressure Transmitter pressure ports and process connections with flush welded stainless steel diaphragm accuracy according to IEC 600: 0, % FSO Nominal pressure from 0... 00 mbar up to

More information

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm DMP Pi Precision Pressure Transmitter pressure ports and process connections with flush welded stainless steel diaphragm accuracy according to IEC 600: 0, % FSO Nominal pressure from 0... 00 mbar up to

More information

PRODUCT CATALOGUE PREssURE switch

PRODUCT CATALOGUE PREssURE switch PRODUCT CATALOGUE PREssURE switch w w w. p a a b. c o m Pressure AT THe HIGHesT LeVeL Successful mediumsized companies are not successful because they are active in many areas, but rather because they

More information

Pressure Transmitter ED 701

Pressure Transmitter ED 701 Pressure Transmitter ED 701 Hygienic and industrial process connections Zero setting function Accuracy < 0.1% FS Quick response time < 25 ms High long-term stability Excellent repeatability Active compensation

More information

HYGRASGARD KFF KFTF HYGRASGARD AFF AFTF HYGRASGARD AFF - LC AFTF - LC

HYGRASGARD KFF KFTF HYGRASGARD AFF AFTF HYGRASGARD AFF - LC AFTF - LC HYGRASGARD AFF - LC AFTF - LC sensors, calibrateable, with and active passive output Quality product for HVAC sector, accuracy % r.h. The calibrateable room humidity and temperature sensor HYGRASGARD KFF

More information

Dimensional drawing face mount flange radial. R = bending radius min. 40 mm. Dimensional drawing face mount flange axial

Dimensional drawing face mount flange radial. R = bending radius min. 40 mm. Dimensional drawing face mount flange axial Incremental Encoder DRS/DRS, face mount flange up to 8,2 Dimensional drawing face mount flange radial Incremental Encoder Connector or cable outlet Protection class up to IP s TTL and HTL Zero-Pulse-Teach

More information

Operating Instructions for Digital Manometer. Model: MAN-SD

Operating Instructions for Digital Manometer. Model: MAN-SD Operating Instructions for Digital Manometer Model: MAN-SD 1. Contents 1. Contents...2 2. Note...3 3. Instrument Inspection...3 4. Regulation Use...4 5. Operating Principle...4 6. Mechanical Connection...5

More information

Absolute encoders multiturn

Absolute encoders multiturn elektronischer electronic multiturn, Multiturn, magnetic magnetisch Sendix M66 / M68 (shaft / hollow shaft) The Sendix M6 with Energy Harvesting Technology is an electronic multiturn encoder in miniature

More information

D5.2 Type. Draw wire mechanics with incremental encoder. Measuring length max. 2 m. Compact and simple. Order code draw wire encoder

D5.2 Type. Draw wire mechanics with incremental encoder. Measuring length max. 2 m. Compact and simple. Order code draw wire encoder with incremental encoder Draw wire encoder A40 Traverse speed max. 0.8 m/s The draw wire system A40 with incremental encoder excels with its compact construction. RoHS Compact and simple Measuring length

More information

TF 212 / TF 212-Ex. Field mounted temperature transmitters, PROFIBUS PA, Pt 100 (RTD), thermocouples, 1 or 2 independent channels 10/11-8.

TF 212 / TF 212-Ex. Field mounted temperature transmitters, PROFIBUS PA, Pt 100 (RTD), thermocouples, 1 or 2 independent channels 10/11-8. TF / TF -Ex Field mounted temperature transmitters, PROFIBUS PA, Pt 00 (RTD), thermocouples, or independent channels 0/-8.70 EN P R O F I PROCESS FIELD BUS B U S Input Resistance thermometer (,, -wire

More information

Single point load cells

Single point load cells SP4M Single point load cells Special features Maximum capacities: kg 200 kg Aluminum High ratio of minimum verification Offcenter load compensation Shielded connection cable Explosion protection and other

More information

Imformation of C091D series

Imformation of C091D series Imformation of C09D series The QTY of contacts is -pin to -pin, the connection method for the thread type, pinhole connections for welding type, press-fit and PCB type. This series of connectors to prevent

More information

BTE5000 / PTE5000 / PTU5000 Series Precision differential pressure transmitters

BTE5000 / PTE5000 / PTU5000 Series Precision differential pressure transmitters FEATURES 5 mbar to 0 bar, 0. to 50 psi differential pressure...6 or...0 ma Precision temperature compensated and calibrated Rugged aluminium housing Female /8" BSP and /8" NPT fittings MEDIA COMPATIBILITY

More information

VOLUMEC. Valve Position Indicator 5

VOLUMEC. Valve Position Indicator 5 VOLUMEC Valve Position Indicator 5 2 KRACHT CORP. 8600 S Wilkinson Way Unit A Perrysburg, OH 43551 USA P +1 419 874 1000 F +1 419 874 1006 flowmeters@krachtcorp.com www.krachtcorp.com VOLUMEC Valve Position

More information

DRS 61: Incremental encoders, number of lines and zero pulse width freely programmable DRS 60: Incremental Encoders with Zero-Pulse-Teach

DRS 61: Incremental encoders, number of lines and zero pulse width freely programmable DRS 60: Incremental Encoders with Zero-Pulse-Teach NEW DRS : Incremental encoders, number of lines and zero pulse width freely programmable DRS : s with Zero-Pulse-Teach Further highlights of this generation of encoders: Simple zero-pulse-teach by pressing

More information

Compact and low-cost monitoring of conductive liquids. Magnetic-inductive flow metering from ifm.

Compact and low-cost monitoring of conductive liquids. Magnetic-inductive flow metering from ifm. Flow sensors www.ifm.com/mid Compact and low-cost monitoring of conductive liquids. Magnetic-inductive flow metering from ifm. For industrial applications Volumetric flow sensor efector mid. High-precision

More information

AUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY HAH1BVW S/08

AUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY HAH1BVW S/08 AUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY HAH1BVW S/08 Introduction The HAH1BVW family is for the electronic measurement of DC, AC or pulsed currents in high power and low voltage automotive applications

More information

Vortex Flow Meters. RVL Series Vortex Flow Meter

Vortex Flow Meters. RVL Series Vortex Flow Meter TM Vortex Meters RVL Series Vortex Meter pplications: Water/Wastewater I Water: Semiconductor, Institutional I Water Skids Semiconductor Equipment Slurry hemical Processing RINE FEERTE IN. ISO 900 : 000

More information

THM80X Series Feature Application. Temperature & Humidity / Flow Measuring Specialist

THM80X Series  Feature Application. Temperature & Humidity / Flow Measuring Specialist THM80X Series Feature Application IP67 protection degree, rugged aluminum case, fit in variety harsh environment Capable of temperature compensation Linear adjustment temperature & humidity by computer,

More information

BMXART0814 analog input module M340-8 inputs - temperature

BMXART0814 analog input module M340-8 inputs - temperature Product data sheet Characteristics BMXART0814 analog input module M340-8 inputs - temperature Main Range of product Product or component type Electrical connection Input output isolation Input level Analogue

More information

Surface-mounting Thermostats ATH Type Series

Surface-mounting Thermostats ATH Type Series Page 1/9 urface-mounting Thermostats ATH eries k enclosure protection IP 54 k tested to IN EN 14597 (replacing IN 3440) Brief description Thermostats control and monitor thermal processes. Instruments

More information

359 Low & Medium Pressure filters. LMP series. Maximum pressure up to 30 bar - Flow rate up to 2400 l/min. Low & Medium Pressure fi lters

359 Low & Medium Pressure filters. LMP series. Maximum pressure up to 30 bar - Flow rate up to 2400 l/min. Low & Medium Pressure fi lters Low & Medium Pressure fi lters LMP 909 series Maximum pressure up to 0 bar Flow rate up to 00 l/min 9 Low & Medium Pressure filters FILTER SIZING The correct filter sizing have to be based on the variable

More information

ISEmax CAM40/CAS40. Technical Information

ISEmax CAM40/CAS40. Technical Information Technical Information Online measurement of nutrient parameters Ion-selective electrode system for the continuous measurement of ammonium and nitrate Application The ion-selective electrode system works

More information

Level Sensor PanCake PR 6251 and Mounting Kit PR 6051

Level Sensor PanCake PR 6251 and Mounting Kit PR 6051 Level Sensor PanCake PR 6251 and Mounting Kit PR 6051 The space-saving solution for simple applications The sensors of the PR 6251 series have been specially designed for simple weighing of silos and horizontal

More information

Field IT 50T Series Transmitters

Field IT 50T Series Transmitters Data Sheet SS/G/A_ Field IT 0T Series Transmitters gauge/absolute pressure transmitter Ranges: -00 to 0000kPa - to 00bar -. to 6000psi Base accuracy : 0.% (BFSL) Chemical Vapour Deposition (CVD) technology

More information

Load Washers. Force. for Forces of 7, kn. F z. Type 9001A A 9081B, 9091B

Load Washers. Force. for Forces of 7, kn. F z. Type 9001A A 9081B, 9091B Force Load Washers for Forces of 7,5... 1 200 kn Type 9001A... 9071A 9081B, 9091B 1-component force sensor for measuring dynamic and quasistatic forces in z direction. F z Calibrated measuring range 100

More information

331 Low & Medium Pressure filters

331 Low & Medium Pressure filters Low & Medium Pressure fi lters LMP 00-0 & 0- series Maximum pressure up to 60 bar - Flow rate up to 70 l/min Low & Medium Pressure filters FILTER SIZING The correct filter sizing have to be based on the

More information

Ex-Floodlight PXLED. (Ex-Zone 1, 2, 21 and 22)

Ex-Floodlight PXLED. (Ex-Zone 1, 2, 21 and 22) Ex-Floodlight PXLED (Ex-Zone 1, 2, 21 and 22) Lighting under harsh conditions The new modular LED floodlight series PXLED is suited for nearly every kind of lighting task in hazardous areas, including

More information

High Pressure fi lters. FMP 039 series. Maximum pressure up to 110 bar - Flow rate up to 80 l/min. High Pressure fi lters

High Pressure fi lters. FMP 039 series. Maximum pressure up to 110 bar - Flow rate up to 80 l/min. High Pressure fi lters High Pressure fi lters FMP 09 series Maximum pressure up to 0 bar Flow rate up to 80 l/min 7 High Pressure fi lters FILTER SIZING The correct filter sizing have to be based on the variable pressure drop

More information

FL ballasts Electronic fixed output. PC TC PRO sr 1/2x11 42 W PC PRO compact

FL ballasts Electronic fixed output. PC TC PRO sr 1/2x11 42 W PC PRO compact FL ballasts EL HE PC TC PRO sr 1/2x11 42 W PC PRO compact Product description CELMA Energy Efficiency Index A2 BAT / A2 T Nominal life-time up to 50,000 h (at ta 50 C with a failure rate max. 0.2 % per

More information

Cartridge Valves Technical Information. Quick reference

Cartridge Valves Technical Information. Quick reference Quick reference Contents CPF0... 8. CP600-5... 8. CP60-5... 8. 066 handle kit... 8.5 MP06... 8.6 MP... 8.6 X05-FD0 Traction manifold... 8.9 X05-FD6 Traction manifold... 8.0 X05-FD0 Traction manifold...

More information

Proximity Sensor Ideal for High Temperatures and Cleaning Processes. Applicable to 120 C

Proximity Sensor Ideal for High Temperatures and Cleaning Processes. Applicable to 120 C ASH & ALAIN INDIA PVT LTD S-00, F.I.E.E., Okhla Industrial Area, Phase-ii, New Delhi-000(India) Tel : 0-797575 Fax : 0-79757 E-mail : sales@ashalain.com Proximity Ideal for High Temperatures and Cleaning

More information

DS 200 DS 200 DRUCK & TEMPERATUR LEITENBERGER GMBH. Electronic Pressure Switch. Stainless Steel Sensor. Electronic Pressure Switch

DS 200 DS 200 DRUCK & TEMPERATUR LEITENBERGER GMBH. Electronic Pressure Switch. Stainless Steel Sensor. Electronic Pressure Switch DRUCK & TEMPERATUR LEITENBERGER GMBH DS 00 Electronic Pressure Switch Stainless Steel Sensor accuracy according to IEC 00: standard: 0. % FSO option: 0. % FSO Nominal pressure: from 0... 00 mbar up to

More information

AC axial compact fan

AC axial compact fan ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-767 Mulfingen Phone +9 798 8- Fax +9 798 8- info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen County court Stuttgart HRA 59

More information

S95.3U01 / S95.3U11. Head mounted temperature transmitters, programmable, Pt 100 (RTD), thermocouples, electrical isolation

S95.3U01 / S95.3U11. Head mounted temperature transmitters, programmable, Pt 100 (RTD), thermocouples, electrical isolation S95.U0 / S95.U Head mounted temperature transmitters, programmable, Pt 00 (RTD), thermocouples, electrical isolation Resistance thermometer (,, wire circuit) Thermocouples Resistance remote signalling

More information

Pressure. 1 Fitting PA R - N R2

Pressure. 1 Fitting PA R - N R2 INTERNAL STRUCTURE (R 1/4) 4 1 2 3 FEATURES High corrosion resistance and drip-proof construction port attachment made of Proven IP-65 grade gauge body (IP-65 in accordance with IEC) Standard product provides

More information

Thermal-Magnetic Circuit Breaker 2210-S2..

Thermal-Magnetic Circuit Breaker 2210-S2.. Thermal-Magnetic Circuit Breaker -S.. Description One, two and three pole thermal-magnetic circuit breakers with trip-free mechanism and toggle actuation (S-type TM CBE to EN 60934/IEC 934). Designed for

More information

MINIATURE MICROSWITCHES - PREMIUM

MINIATURE MICROSWITCHES - PREMIUM 0/06 MINIATURE MICROSWITCHES - PREMIUM V - 86 High precision flexible leaf snap-action mechanism Operation without balance-point, even at extremely slow actuating speed Broad range of operating forces

More information

Thermal-Magnetic Circuit Breaker 2210-S2..

Thermal-Magnetic Circuit Breaker 2210-S2.. Thermal-Magnetic Circuit Breaker -S.. Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 6094/IEC 94). Designed for

More information

Surface-mounting thermostats Series ATH

Surface-mounting thermostats Series ATH JUMO GmbH & Co. KG Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 E-mail: mail@jumo.net Internet: www.jumo.net

More information

Direct Operated Type Solenoid Operated Proportional Directional Control Valve

Direct Operated Type Solenoid Operated Proportional Directional Control Valve Direct Operated Type Solenoid Operated Proportional Directional Control Valve Features These four-way proportional directional control valves enable control of the forward and reverse motion of an actuator.

More information

AC axial compact fan

AC axial compact fan ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-7467 Mulfingen Phone +49 798 8-0 Fax +49 798 8-0 info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen County court Stuttgart HRA

More information

Thermal-Magnetic Circuit Breaker 2210-S2..

Thermal-Magnetic Circuit Breaker 2210-S2.. Thermal-Magnetic Circuit Breaker -S.. Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 60934/IEC 934). Designed for

More information

DVZ. Vortex Flowmeter Compact. for low viscosity liquids. Range: l/min. Accuracy: ±2.5% of full scale. p max : 20 bar; t max : 80 C

DVZ. Vortex Flowmeter Compact. for low viscosity liquids. Range: l/min. Accuracy: ±2.5% of full scale. p max : 20 bar; t max : 80 C Vortex Flowmeter Compact for low viscosity liquids measuring monitoring analysing DVZ Range: 0.4. 000 l/min Accuracy: ±.% of full scale p max : 0 bar; t max : 80 C Connections: G ¼... G, ¼" NPT..." NPT

More information

ISEmax CAS40D. Technical Information

ISEmax CAS40D. Technical Information Technical Information ISEmax CAS40D Online measurement of nutrient parameters Ion-selective electrodes for the continuous measurement of ammonium, nitrate and other ions Application The ion-selective sensor

More information

Installation guide 862 MIT / MIR

Installation guide 862 MIT / MIR Installation guide 862 MIT / MIR in combination with: 864 MTT or 863 MRT or (dual) spot element November 2005 Part no. 4416.232_Rev3 Enraf BV PO Box 812 2600 AV Delft Netherlands Tel. : +31 15 2701 100

More information

Impedance relay and protection assemblies

Impedance relay and protection assemblies RXZK 21H, 22H, 23H 509 006-BEN Page 1 Issued June 1999 Changed since July 1998 Data subject to change without notice (SE970175) (SE970184) Features Micro-processor based impedance relay with R and X settings

More information

EVOTRON WET ROTOR ELECTRONIC CIRCULATORS TECHNICAL DATA APPLICATIONS ADVANTAGES

EVOTRON WET ROTOR ELECTRONIC CIRCULATORS TECHNICAL DATA APPLICATIONS ADVANTAGES TECNICAL DATA EVOTRON Operating range: from, -, m3/h with head of up to metres. Pumped liquid temperature range: from - C to + C. Working pressure: bar ( kpa). Protection class: IP X. Insulation class:

More information

Load Washers. Force kn until kn. Type 9101A A

Load Washers. Force kn until kn. Type 9101A A Force Load Washers 0... 20 kn until 0... 700 kn Type 9101A... 9107A Force sensor for measuring quasistatic and dynamic forces in industrial monitoring tasks. F z The force sensors are delivered uncalibrated

More information

Calio-Therm NC Type Series Booklet

Calio-Therm NC Type Series Booklet High-efficiency Drinking Water Pump Type Series Booklet Legal information/copyright Type Series Booklet All rights reserved. The contents provided herein must neither be distributed, copied, reproduced,

More information

Electromagnetic Flowmeter

Electromagnetic Flowmeter Overview Flokal B.V. smart electromagnetic flow meter is hallmarked by its high performance and reliability that are based on successful, field-proven technology. It s being widely used in industries such

More information

SITRANS F flowmeters. SITRANS F US System information SITRANS F US Ultrasonic flowmeters 4/181

SITRANS F flowmeters. SITRANS F US System information SITRANS F US Ultrasonic flowmeters 4/181 Siemens AG 09 SITRANS F flowmeters System information Overview Siemens offers two types of ultrasonic flowmeters, in-line flowmeters and clamp-on flowmeters. This offers the end user the maximum flexibility

More information

Maximum pressure 420 bar Flow rate to 152 l/min. 560 bar. 140 l/min. Flow rate l/min FMM 050 1/2 1,50 3/4 1,00. Δp bar 0,50 0,00 FHA 051 1,50 1,00

Maximum pressure 420 bar Flow rate to 152 l/min. 560 bar. 140 l/min. Flow rate l/min FMM 050 1/2 1,50 3/4 1,00. Δp bar 0,50 0,00 FHA 051 1,50 1,00 FMM 00 Maximum pressure 0 bar Flow rate to l/min FHA 0 Maximum pressure 60 bar Flow rate to 0 l/min Technical data FMM 00 Filter housing (Materials) Head: Cast iron (chemical heat treatment) Housing: Steel

More information

I nllk 08018/18 I nllk I nllk 08036/36 I nllk I I nllk 08058/58 I

I nllk 08018/18 I nllk I nllk 08036/36 I nllk I I nllk 08058/58 I I nllk / I x W x W x W x W x W Technical data Cooper Crouse-Hinds - all rights reserved nllk / nllk nllk / nllk nllk / Marking to //EC II G Ex na II T / II D td A IP T C EC Conformity Statement PTB ATEX

More information

Operating instructions Magnetic-inductive flow meter SM6x04 SM7x04 SM8x04

Operating instructions Magnetic-inductive flow meter SM6x04 SM7x04 SM8x04 Operating instructions Magnetic-inductive flow meter SM6x04 SM7x04 SM8x04 UK 80223776 / 00 11 / 2018 Contents 1 Preliminary note...3 2 Safety instructions...4 3 Functions and features...4 4 Function...5

More information

BMXART0814 analog input module M340-8 inputs - temperature

BMXART0814 analog input module M340-8 inputs - temperature Characteristics analog input module M340-8 inputs - temperature Complementary Analog/Digital conversion Analogue input resolution Input impedance Permitted overload on inputs Common mode rejection Differential

More information

Silicon Temperature Sensors KT 100 KT 110 KT 130 KT 210 KT 230. KTY 11-x KTY 13-x KTY 21-x KTY 23-x KTY 19-6 KTY 16-6

Silicon Temperature Sensors KT 100 KT 110 KT 130 KT 210 KT 230. KTY 11-x KTY 13-x KTY 21-x KTY 23-x KTY 19-6 KTY 16-6 Silicon Temperature Sensors KT 100 KT 110 KT 130 KT 210 KT 230 KTY 16-6 KTY 10-x KTY 11-x KTY 13-x KTY 21-x KTY 23-x KTY 19-6 Features Temperature dependent resistor with positive temperature coefficient

More information

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-T...

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-T... Magnetic and Hydraulic-Magnetic Circuit Breaker 830-T... Description ngle, two and three pole magnetic and hydraulic-magnetic circuit breakers with trip-free mechanism and toggle actuation. A choice of

More information

MIK. Electromagnetic Flowmeter Compact. for conductivity liquids. Range from liquids, acids and caustic solutions:

MIK. Electromagnetic Flowmeter Compact. for conductivity liquids. Range from liquids, acids and caustic solutions: Electromagnetic Flowmeter Compact for conductivity liquids measuring monitoring analysing MIK Range from liquids, acids and caustic solutions: 0.0-0. 3-700 l/min frequency-, switching-, analogue output

More information

2-way proportional throttle valve for block installation

2-way proportional throttle valve for block installation -way proportional throttle valve for block installation Types FES; FESE Sizes to Component series X Maximum operating pressure bar Maximum flow 800 l/min at Δp = 0 bar Table of contents Contents Page Features

More information

A wide selection of pipe and orifice sizes is offered. Valves are available with threaded ports in brass and stainless steel.

A wide selection of pipe and orifice sizes is offered. Valves are available with threaded ports in brass and stainless steel. Solenoid Valve Waterhammer-Free, 0- PSI /-Way; NPT - NPT; 0- PSI Advantages/Benefits Type 63 Waterhammer-free Low noise Zero differential pressure ompact design with high flow rates Low maintenance oil

More information

High Pressure fi lters. FHB series. Maximum pressure up to 320 bar - Flow rate up to 485 l/min. High Pressure fi lters

High Pressure fi lters. FHB series. Maximum pressure up to 320 bar - Flow rate up to 485 l/min. High Pressure fi lters High Pressure fi lters FHB series Maximum pressure up to 0 bar - Flow rate up to 8 l/min 8 High Pressure fi lters FILTER SIZING The correct filter sizing have to be based on the variable pressure drop

More information

Amphenol C 091 A/B/D. Circular Connectors. Amphenol-Tuchel Electronics GmbH

Amphenol C 091 A/B/D. Circular Connectors. Amphenol-Tuchel Electronics GmbH Amphenol C 091 A/B/D Circular Connectors Amphenol-Tuchel Electronics GmbH General information These connectors are designed and produced in conformity with the low-voltage directive (/3/EWG) respectively

More information

Operating instructions Magnetic-inductive flow sensor SM6004 SM7004 SM / / 2014

Operating instructions Magnetic-inductive flow sensor SM6004 SM7004 SM / / 2014 Operating instructions Magnetic-inductive flow sensor SM6004 SM7004 SM8004 80003223 / 00 05 / 2014 Contents 1 Preliminary note...3 1.1 Symbols used...3 2 Safety instructions...4 3 Functions and features...5

More information

387 Low & Medium Pressure filters

387 Low & Medium Pressure filters Low & Medium Pressure fi lters LMD 000 & series Maximum pressure up to 6 bar Flow rate up to 90 l/min 87 Low & Medium Pressure filters FILTER SIZING The correct filter sizing have to be based on the variable

More information

High Pressure fi lters. FHM series. Maximum pressure up to 320 bar - Flow rate up to 450 l/min. High Pressure fi lters

High Pressure fi lters. FHM series. Maximum pressure up to 320 bar - Flow rate up to 450 l/min. High Pressure fi lters High Pressure fi lters FHM series Maximum pressure up to 0 bar - Flow rate up to 0 l/min 67 High Pressure fi lters FILTER SIZING The correct filter sizing have to be based on the variable pressure drop

More information

Flow Meter FVone-NP-CA. FVone-NP-CA 11 (Plug-in type) (Screw-in type) Recommended for: DN 20 DN 80 Required accessory: Cable type 31.

Flow Meter FVone-NP-CA. FVone-NP-CA 11 (Plug-in type) (Screw-in type) Recommended for: DN 20 DN 80 Required accessory: Cable type 31. FVone-NP- 00/ (Push-in type) Recommended for: DN and bigger Required accessory: Threaded installation bush able type Optional accessory: PTFE sealing ring Locking set FVone-NP- 0/0 (Screw-in type) Recommended

More information

LMP series Filter element according to DIN Maximum pressure up to 30 bar - Flow rate up to 2000 l/min

LMP series Filter element according to DIN Maximum pressure up to 30 bar - Flow rate up to 2000 l/min Low & Medium Pressure fi lters LMP 90090 series according to DIN 0 Maximum pressure up to 0 bar Flow rate up to 000 l/min Low & Medium Pressure filters FILTER SIZING The correct filter sizing have to be

More information

all stainless steel transducer multimedia compatibility

all stainless steel transducer multimedia compatibility all stainless steel transducer multimedia compatibility High-Performance Silicon technology LARGE INVENTORY Fast Shipment! 0-0.07 to 0-690 bar 100 mv, 0 to 5 V, and 4 to 20 ma Outputs U 1, 2 & 5 psi Low

More information

4/4-way servo solenoid directional control valves, directly operated, with electrical position feedback and on-board electronics (OBE)

4/4-way servo solenoid directional control valves, directly operated, with electrical position feedback and on-board electronics (OBE) 4/4-way servo solenoid directional control valves, directly operated, with electrical position feedback and on-board electronics (OBE) RE 9035/. Replaces: 05. 1/1 Type 4WRPEH 6 Size 6 Unit series X Maximum

More information