ISO-C Series chemical Pump

Size: px
Start display at page:

Download "ISO-C Series chemical Pump"

Transcription

1

2 Structural drawing FEATURES ISO-C series chemical process pump, this product carried out the standard o GB/T perormance and dimension o axial suction centriugal pump (bar) ISO-C series pump take in appearance designation o type EN pump with strengthen tendon that make appearance better, operation more saely and credible, longer lietime. Sealing gland packing seal or mechanical seal single ace, balancing mechanical seal, double ace balancing mechanical seal ISO-C services chemical process pump it's developed on the basis o ISO series pump. It is have two type o Impeller which is close type impeller H as standard and open type impeller K which makes it has excellent perormance on transporting the liquid with large solids. APPLICATION It is mainly used in industry department o oil, chemical industry, synthetic iber, power station, metallurgy, ood, medicine, pulp and paper mills, mining, reineries, etc. mainly transporting the medium which not contain suspend grain and prohibit pollution. OPERATION CONDITION Capacity :. 0m/hr Head :. m Speed (n) = r/min, r/min Temperature medium : 0 deg C - +0 deg C Designation ISO-C A/B/C K H Close type impeller structure K Open type impeller structure A. B. C Impeller cutting Impeller nominal diameter Outlet diameter Inlet diameter Standard chemical pump

3 ISO Collection o characteristic curve H(m) n s = n s = n s = ns= n s = n s = n s = n s = r/min H(m) ns= ns= ns= ns= Q(m /h) ns= ns= ns= ns= ns= ns= 0 ns= ns= Q(m /h)

4 ISO-C Sectional Drawing 0 ISO-C Main Parts sheet o ISO Pump NO. Name Pump casing Impeller Casing cover Stuing seal Stuing cover Frame Material Stainless steel Stainless steel Stainless steel Stainless steel HT NO. 0 Name Bearing cover Bearing cover Bose Mechanical seal Mechanical seal cover Material HT HT QA Stainless steel

5 ISO-C Sectional Drawing 0 0 ISO-C Main Parts sheet o ISO Pump NO. Name Pump casing Front wearable board Impeller Casing cover Stuing seal Stuing cover Material Stainless steel Stainless steel Stainless steel Stainless steel Stainless steel NO. 0 Name Frame Bearing cover Bearing cover Bose Mechanical seal Mechanical seal cover Material HT HT HT QA Stainless steel

6 Perormance chart ISO-C-- ISO-C-- ISO-C--0 ISO-C-- ISO-C0-- ISO-C0--A ISO-C0-- ISO-C0--A ISO-C0--B ISO-C0-- ISO-C0--A ISO-C0--B ISO-C0--0 ISO-C0--0A ISO-C0--0B ISO-C Speed Capacity Head Shat Power Pump weight margin Necessary gasetching Impeller diameter r/min (Kg) mm m /h m kw Motor Power Eicency.. (NPSH)r (m)

7 Perormance Data sheet ISO-C-0-A ISO-C-0-B ISO-C-0- ISO-C-0-A ISO-C-0-B ISO-C-- ISO-C--A ISO-C--B ISO-C--0 ISO-C--0A ISO-C--0B ISO-C-- Speed Capacity Head Shat Power Pump weight margin Necessary gasetching Impeller diameter r/min (Kg) mm m /h m kw Motor Power Eicency.. (NPSH)r (m)

8 Perormance Data sheet ISO-C--A ISO-C--B ISO-C--C ISO-C-- ISO-C--A ISO-C--B ISO-C-- ISO-C--A ISO-C--B ISO-C-0- ISO-C-0-A ISO-C-0-B Speed Capacity Head Shat Power Pump weight margin Necessary gasetching Impeller diameter r/min (Kg) mm m /h m kw Motor Power Eicency.. (NPSH)r (m)

9 ISO-C-0-0 ISO-C-0-0A ISO-C-0-0B ISO-C-0- ISO-C-0-A ISO-C-0-B ISO-C-0-C ISO-C-- ISO-C--A ISO-C-- ISO-C--A ISO-C-- Perormance Data sheet Speed Capacity Head Shat Power Pump weight margin Necessary gasetching Impeller diameter r/min (Kg) mm m /h m kw Motor Power Eicency.. (NPSH)r (m)

10 ISO-C-- ISO-C--A ISO-C--B ISO-C--0 ISO-C--0A ISO-C--0B ISO-C-- ISO-C--A ISO-C--B ISO-C--C ISO-C-- ISO-C--A Perormance Data sheet Speed Capacity Head Shat Power Pump weight margin Necessary gasetching Impeller diameter r/min (Kg) mm m /h m kw Motor Power Eicency.. (NPSH)r (m)

11 ISO-C--B ISO-C--0 ISO-C--0A ISO-C--0B ISO-C--0C ISO-C-- ISO-C--A ISO-C--B ISO-C--C ISO-C--0 ISO-C--0A ISO-C--0B ISO-C--0C ISO-C0--0 ISO-C0--0A Perormance Data sheet Speed Capacity Head Shat Power Pump weight margin Necessary gasetching Impeller diameter r/min (Kg) mm m /h m kw Motor Power Eicency.. (NPSH)r (m)

12 Perormance Data sheet Speed Capacity Head Shat Power Pump weight margin Necessary gasetching Impeller diameter r/min (Kg) mm m /h m kw Motor Power Eicency.. (NPSH)r (m) ISO-C0--0B ISO-C0-- ISO-C0--A ISO-C0--B ISO-C0--0 ISO-C0--0A ISO-C0--0B ISO-C0--0C ISO-C-0-0 ISO-C-0-0A ISO-C-0-0B ISO-C-0- ISO-C-0-A ISO-C-0-B ISO-C-0-0 ISO-C-0-0A ISO-C-0-0B ISO-C-0-0C ISO-C-0- ISO-C-0-A ISO-C-0-B ISO-C-0-C ISO-C-0-D ISO-C--0 ISO-C--0A ISO-C--0B ISO-C0-- ISO-C0--A ISO-C0--B ISO-C0--C ISO-C0--0 ISO-C0--0A ISO-C0--0B ISO-C0--0C ISO-C0-- ISO-C0--A ISO-C0--B ISO-C0--C ISO-C0-0- ISO-C0-0-A ISO-C0-0-B ISO-C0-0-0 ISO-C0-0-0A ISO-C0-0-0B ISO-C0-0-0C / 0 /0 0/

13 Outline Dimension Drawing Outline Dimension Sheet Foot support Bracket a h h b m m d L X k k ISO-C-- ISO-C-- ISO-C-- ISO-C0-- ISO-C0-- ISO-C0-- ISO-C-0- ISO-C-0- ISO-C-- ISO-C-- ISO-C-- ISO-C-0- ISO-C-- ISO-C--0 ISO-C0--0 ISO-C--0 ISO-C-- ISO-C-0-0 ISO-C-0- ISO-C-- ISO-C-- ISO-C--0 ISO-C-- ISO-C-- ISO-C--0 ISO-C-- ISO-C--0 ISO-C0--0 ISO-C0-- ISO-C0--0 ISO-C-0-0 ISO-C--0 ISO-C-0- ISO-C-0-0 ISO-C0-- ISO-C-0- ISO-C0--0 ISO-C0-- ISO-C0-0- ISO-C0-0-0 XA0- XA0- XA0- XA0- XA0- XA0- XA0- XA0- XA0- XA0- XA0- XA0- XA0- XA0- XA0- XA0- XA0-0 XA0- XA0- IHH0- XA0- XA0-0 XA0-0 XA0-0 XA0-0 XA0- XA0- DFCZ0- DFJ-0 XA0- XA0- DFCZ0- XA0- XA0- DFCZ0- XA0- XA0- IHH-0 DFCZ0- IHH a L d k k m m m m W X h h S S b n n n n m m n n n n s s Pump Pump Base Bolt Hole Shat Face Space W

14 Pump Inlet & Outlet Flange sketch Map D D D D d d DN DN b b n d0 n d0 ISSO GB/T. PN.MPa Suction Flange Dimension Discharge Flange Dimension DN D D d b nx d0 DN D D d b nx d0 ISO-C-- ISO-C-- ISO-C-- 0 x x ISO-C--0 ISO-C0-- ISO-C0-- ISO-C x x ISO-C0--0 ISO-C x ISO-C-0- ISO-C-- 0 x ISO-C--0 0 x ISO-C-- ISO-C-- 0 x ISO-C-- ISO-C-0-0 x ISO-C x ISO-C-0- ISO-C-- 0 x ISO-C-- x 0 ISO-C-- 0 x ISO-C--0 ISO-C-- ISO-C--0 ISO-C-- 0 x 0 x ISO-C--0 ISO-C0--0 ISO-C0-- 0 x 0 x ISO-C0--0 ISO-C-0-0 ISO-C-0- x ISO-C x ISO-C-0- ISO-C--0 ISO-C0-- x 0 ISO-C0--0 x ISO-C0-- ISO-C0-0- ISO-C x 0 x

15 Installation Dimension Drawing a H H A L L n d L h H H B B Installation Dimension Motor Power S- kw Power. Dimension A L L L L L a L L B B B H H h H H n X d 0 0. x -M x 0 Pedestal Number ISO-C-- L x -M x 0 ISO-C-- ISO-C-- ISO-C--0 L- L- L- M- M- S- S- M- M x x x x x x x x x -M x 0 -M x 0 -M x 0 -M x 0 -M x 0 -M0 x 0 -M0 x 0 -M0 x 0 -M0 x 0 L-. 0 x -M0 x x -M x 0 S x -M x 0 ISO-C0-- L x -M x 0 L x -M x 0 M- 0 0 x -M x x -M x x -M x 0 S x -M x 0 ISO-C0-- L x -M x 0 L x -M x 0 M- 0 0 x -M x 0 S x -M x x -M x 0 S- 0 0 x -M x 0 ISO-C0-- L x -M x 0 L- 0 0 x -M x 0 M- 0 0 x -M x 0

16 Installation Dimension Drawing a H H A L L L h H H n d B B Installation Dimension Motor Power S- kw Power. Dimension A L L L L L a L L B B B H H h H H n X d M0 x 0 Pedestal Number ISO-C0-- S M0 x 0 ISO-C0--0 M- L- L- L- S- M- M- L- M M0 x 0 -M0 x 0 -M0 x 0 -M0 x 0 -M0 x 0 -M0 x 0 -M0 x 0 -M0 x 0 -M0 x M x M x 0 ISO-C-0- L- L M x 0 -M x 0 M M x 0 S M0 x M x M x 0 S M x 0 L M x 0 ISO-C-0- L M x 0 M M x 0 S M0 x 0 S M0 x 0 M M0 x 0 ISO-C-- - S M x 0 -M x 0

17 Installation Dimension Drawing a L L L A H H h H H B B n d Installation Dimension Pedestal Number kw Power Motor Power Dimension A L a L L L L L L B B B H H h H H n X d ISO-C--0 ISO-C-- ISO-C-- ISO-C-- L- L- S- S- M- M- L- L- M- M- M- L- M- L- L- M- S- M- L- M- L- L- M x x x x x x x x x x x x x x x x x x x x x xmx0 xmx0 xm0x0 xm0x0 xm0x0 xm0x0 xm0x0 xm0x0 xm0x0 xm0x0 xm0x0 xm0x0 xm0x0 xm0x0 xm0x0 xm0x0 xm0x0 xm0x0 xm0x0 xmx0 xmx0

18 Installation Dimension Drawing a L L L A H H h H H B B n d Installation Dimension Pedestal Number kw Power Motor Power Dimension A L a L L L L L L B B B H H h H H n X d ISO-C-- ISO-C-0- ISO-C-0-0 ISO-C-- S- L- M- S- S- M- - S- L- L- S- S- M- M- S- L- L- L- M- S- M- M- L- L- L- M- S x x x x x x x x x x x x x x x x x x x x x x x x x x xmx0 xmx0 xmx0 xm0x0 xm0x0 xm0x0 xmx0 xmx0 xmx0 xmx0 xm0x0 xm0x0 xm0x0 xm0x0 xmx0 xmx0 xmx0 xmx0 xmx0 xm0x0 xm0x0 xm0x0 xm0x0 xmx xm0x0 xm0x0 xm0x0

19 Installation Dimension Drawing a L L L A H H h H H B B n d Installation Dimension Pedestal Number kw Power Motor Power Dimension A L a L L L L L L B B B H H h H H n X d M- L- M- L- L- M- L- M- S- M- M- L- M- L- L- M- 0M- S- S- L- L- L- S- M- M- L- S- L- L ISO-C-0- ISO-C-- ISO-C-- ISO-C-0-0 x x x x x x x x x x x x x x x x x x xm0x0 xm0x0 xm0x0 xmx xmx xmx xm0x0 xm0x0 xm0x0 xm0x0 xmx0 xm0x0 xm0x0 xmx xmx0 xmx0 xmx0 xmx0 xm0x0 xm0x0 xmx xm0x0 xm0x0 xm0x0 xm0x0

20 Installation Dimension Drawing a L L L A H H h H H B B n d Installation Dimension Pedestal Number kw Power Motor Power Dimension A L a L L L L L L B B B H H h H H n X d ISO-C-- ISO-C--0 ISO-C-- L- M- S- M- M- M- L- L- L- M- S- M- M- M- L- L- L- M- M- S- M- M- L- L- M x x x x x x x x x x x x x x x x x x xm0x0 xm0x0 xm0x0 xm0x0 xm0x0 xm0x0 xm0x0 xm0x0 xm0x0 xm0x0 xm0x0 xm0x0 xm0x0 xm0x0 xmx0 xmx0 xmx0 xmx0 xmx xmx

21 Installation Dimension Drawing a L L L A H H h H H B B n d Installation Dimension Pedestal Number kw Power Motor Power Dimension A L a L L L L L L B B B H H h H H n X d ISO-C-- ISO-C--0 ISO-C-- ISO-C--0 0M- S- S- M- M- L- M- L- M- 0M- S- M- S- M- S- M- M- L- L- M- 0M- S- S- M- M- L- M- L- M- 0M- S x x x x x x x x x x xm0x0 xm0x0 xm0x0 xm0x0 xm0x0 xm0x0 xm0x0 xm0x0 xm0x0 xm0x0

22 Installation Dimension Drawing a L L L A H H h H H B B n d Installation Dimension Pedestal Number kw Power Motor Power Dimension A L a L L L L L L B B B H H h H H n X d ISO-C0--0 ISO-C-- ISO-C--0 ISO-C--0 M- S- M- L- M- L- L- S- S- M- S- M- L- L- L- L- S- M- 0M- M- L- M- L- L xmx

23 Installation Dimension Drawing a L L L A H H h H H B B n d Installation Dimension Pedestal Number kw Power Motor Power Dimension A L a L L L L L L B B B H H h H H n X d ISO-C-0- ISO-C-0-0 ISO-C0--0 ISO-C0-- M- L- L- S- 0M- L- S- M- 0M- S- M- L- L- S- M- 0M- S- S- M- 0M- S- M- S

24 Installation Dimension Drawing a L L L A H H h H H B B n d Installation Dimension Pedestal Number kw Power Motor Power Dimension A L a L L L L L L B B B H H h H H n X d ISO-C0-- ISO-C--0 ISO-C-0-0 ISO-C-0- M- 0M- S- M- S- L- 0M- S- M- S- M- L- L- M- L- L- S- M- 0M- L- S- M- 0M- S- M- S x x x x x x x

25 Installation Dimension Drawing a L L L A H H h H H B B n d Installation Dimension Pedestal Number kw Power Motor Power Dimension A L a L L L L L L B B B H H h H H n X d ISO-C0-- ISO-C0--0 ISO-C0-0- ISO-C M- S- M- S- M- L- M- S- S- M- L- L- M- L- 0M- S- M- S- M- S- M- S- M- L- L- M- L x x x x x x x x x x x x x x x x x x x x x x x x

Standardized Chemical Pumps. Fields of Application. Designation. Design. Operating Data. Type Series Booklet /7-10 G2 CPK-H

Standardized Chemical Pumps. Fields of Application. Designation. Design. Operating Data. Type Series Booklet /7-10 G2 CPK-H Type Series Booklet.5/7-0 G CPK-H Standardized Chemical Pumps to EN 5/ISO 5/ISO 599, heatable Automation products available: Hya-Drive Hyamaster hyatronic Fields of Application CPK-H pumps are used for

More information

3 Energy Exchange in Turbomachines

3 Energy Exchange in Turbomachines 3 Energy Exchange in Turbomachines Problem 1 The solved and unsolved examples of this chapter are meant to illustrate the various forms of velocity triangles and the variety of the turbomachines. In addition,

More information

Contents. Identification LHC. Horizontal split case pumps. Type key. Identification Type key

Contents. Identification LHC. Horizontal split case pumps. Type key. Identification Type key Contents dentification Type key Product data ntroduction Applications Features and benefits Performance range pole pole pole Construction Sectional drawing Construction features Test pressure Operating

More information

50 Hz n= 2900 rpm. Standardised EN 733 centrifugal pumps INSTALLATION AND USE. PERFORMANCE RANGE Flow rate up to 6000 l/min (360 m³/h) Head up to 98 m

50 Hz n= 2900 rpm. Standardised EN 733 centrifugal pumps INSTALLATION AND USE. PERFORMANCE RANGE Flow rate up to 6000 l/min (360 m³/h) Head up to 98 m F Standardised EN 733 centrifugal pumps Hz n= 9 rpm Clean water Industrial use PERFORMNCE RNGE Flow rate up to (3 ) Head up to 9 m PPLICTION LIMITS Manometric suction lift up to 7 m Liquid temperature

More information

MULTISTAGE CENTRIFUGAL PUMP TPH 2/4/8/12/25/50T. 50Hz. WALRUS PUMP ISO 9001 Certified

MULTISTAGE CENTRIFUGAL PUMP TPH 2/4/8/12/25/50T. 50Hz. WALRUS PUMP ISO 9001 Certified MULTISTAGE CENTRIFUGAL PUMP TPH /////T Hz WALRUS PUMP ISO Certified TPH Applications The WALRUS TPH Series is horizontal multistage centrifugal pump, suitable for clean water/liquid without abrasive matters.

More information

PR CYCLONE SECONDARY SHUTOFF

PR CYCLONE SECONDARY SHUTOFF EN PR CYCLONE SECONDARY SHUTOFF ORIGINAL INSTRUCTIONS CYCLONE SECONDARY SHUTOFF PR530 CYCLONE SECONDARY SHUTOFF PR330 CYCLONE SECONDARY SHUTOFF PR200-250 CYCLONE SECONDARY SHUTOFF PR150 TECHNICAL DATA

More information

barmesapumps.com SELF-PRIMING CENTRIFUGAL TRASH PUMP SPECIFICATIONS Series: SH8-U Suction: 8" Discharge: 8" Spherical solids handling: 3"

barmesapumps.com SELF-PRIMING CENTRIFUGAL TRASH PUMP SPECIFICATIONS Series: SH8-U Suction: 8 Discharge: 8 Spherical solids handling: 3 SELF-PRIMING CENTRIFUGAL TRASH PUMP Series: SH-U Suction: " Discharge: " Spherical solids handling: 3" SIZE BEARING - PUMP END " x " NPT, lbs., female flange. Open single ball, radial load. LIQUID TEMPERATURE

More information

DOMESTIC HOT WATER PUMPS WITH FIXED-SPEED MOTOR, 3x400V AP-, AKP- and AEP- series, threaded G1/2 G1 ¼ LOREM IPSUM JE ZULT MAAR 60 HZ.

DOMESTIC HOT WATER PUMPS WITH FIXED-SPEED MOTOR, 3x400V AP-, AKP- and AEP- series, threaded G1/2 G1 ¼ LOREM IPSUM JE ZULT MAAR 60 HZ. LOREM IPSUM JE ZULT MAAR HZ m Head m/s m/s m/s m/s m/s Ø m Ø Ø Ø Ø l/s Flow kw Shaft power P Ø m/h Ø 9 Ø Ø kw 9 Total input power P Ø DOMESTIC HOT WATER PUMPS WITH FIXED-SPEED MOTOR, xv AP-, AKP- and AEP-

More information

IL series. Centrifugal marine IN-LINE pumps

IL series. Centrifugal marine IN-LINE pumps IL series Centrifugal marine IN-LINE pumps DESCRIPTION Vertically built centrifugal IN-LINE pumps are made with standardized DIN-22 parts, with in-line suction and discharge flanges. This arrangement requires

More information

TPH. 60Hz. Standard mode TPH 4T 2K. Code TPH 4T 2K S F A H

TPH. 60Hz. Standard mode TPH 4T 2K. Code TPH 4T 2K S F A H C US NSF/ANSI TPH Applications: The TPH Series are modernly designed with quiet and high efficient operation pumps, suitable for dependable water transfer, circulating or booster service. -Industrial circulation

More information

Calio-Therm NC Type Series Booklet

Calio-Therm NC Type Series Booklet High-efficiency Drinking Water Pump Type Series Booklet Legal information/copyright Type Series Booklet All rights reserved. The contents provided herein must neither be distributed, copied, reproduced,

More information

High-efficiency Circulator Pump. Rio-Eco N / Rio-Eco Z N. Type Series Booklet

High-efficiency Circulator Pump. Rio-Eco N / Rio-Eco Z N. Type Series Booklet High-efficiency Circulator Pump Rio-Eco N / Rio-Eco Z N Type Series Booklet Legal information/copyright Type Series Booklet Rio-Eco N / Rio-Eco Z N KSB Aktiengesellschaft All rights reserved. The contents

More information

LECTURE 6- ENERGY LOSSES IN HYDRAULIC SYSTEMS SELF EVALUATION QUESTIONS AND ANSWERS

LECTURE 6- ENERGY LOSSES IN HYDRAULIC SYSTEMS SELF EVALUATION QUESTIONS AND ANSWERS LECTURE 6- ENERGY LOSSES IN HYDRAULIC SYSTEMS SELF EVALUATION QUESTIONS AND ANSWERS 1. What is the head loss ( in units of bars) across a 30mm wide open gate valve when oil ( SG=0.9) flow through at a

More information

P U M P S. The quality standard for hydraulic efficiency and suction lift. PERIPHERAL PUMPS TEP/ TSP - SERIES 50Hz

P U M P S. The quality standard for hydraulic efficiency and suction lift. PERIPHERAL PUMPS TEP/ TSP - SERIES 50Hz P U M P S THE BENCHMARK FOR PERFORMANCE The quality standard for hydraulic efficiency and suction lift. PERIPHERAL PUMPS TEP/ TSP - SERIES 5Hz I N D E X TEP / TSP SERIES - PERIPHERAL PUMPS Page No. General

More information

Contents. Performance Curves/Technical Data. General Data Performance Range Sectional Drawing TPH 2T TPH 4T TPH 8T TPH 12T TPH 25T TPH 50T

Contents. Performance Curves/Technical Data. General Data Performance Range Sectional Drawing TPH 2T TPH 4T TPH 8T TPH 12T TPH 25T TPH 50T Contents General Data Performance Range Sectional Drawing Performance Curves/Technical Data T T T T T 8T T T T T T T 7 9 T Series Multistage Centrifugal Pump Hz Power:.. kw Head: Up to 7M Flow: Up to L/min

More information

EVOTRON WET ROTOR ELECTRONIC CIRCULATORS TECHNICAL DATA APPLICATIONS ADVANTAGES

EVOTRON WET ROTOR ELECTRONIC CIRCULATORS TECHNICAL DATA APPLICATIONS ADVANTAGES TECNICAL DATA EVOTRON Operating range: from, -, m3/h with head of up to metres. Pumped liquid temperature range: from - C to + C. Working pressure: bar ( kpa). Protection class: IP X. Insulation class:

More information

TPH Series WALRUS PUMP. Multi-stage Centrifugal Pump. All specifications are subject to change without notice. 014

TPH Series WALRUS PUMP. Multi-stage Centrifugal Pump. All specifications are subject to change without notice. 014 T Series WLRUS PUMP ll specifications are subject to change without notice. Multistage entrifugal Pump T T pplications The WLRUS T Series is horizontal multistage centrifugal pump, suitable for clean water/liquid

More information

NKVE VERTICAL AXIS MULTISTAGE CENTRIFUGAL PUMPS WITH MCE/P INVERTER

NKVE VERTICAL AXIS MULTISTAGE CENTRIFUGAL PUMPS WITH MCE/P INVERTER NKVE 1-1--3--6-9 VERTICAL AIS MULTISTAGE CENTRIFUGAL PUMPS WIT MCE/P INVERTER TECNICAL DATA Operating range: fro to 118 3 /h with head up to 31 etres. Puped liquid: clean, free of solids and abrasives,

More information

Standardized Chemical Pumps to EN /ISO 2858/ISO 5199 sealless, with magnetic drive. Fields of Application. Designation. Design.

Standardized Chemical Pumps to EN /ISO 2858/ISO 5199 sealless, with magnetic drive. Fields of Application. Designation. Design. Type series booklet.5/- G2 Magnochem Standardized Chemical Pumps to EN 5/ISO 25/ISO 99 sealless, with magnetic drive Automation products available: PumpExpert Hyamaster hyatronic Fields of Application

More information

P U M P S. The quality standard for hydraulic efficiency and suction lift. PERIPHERAL PUMPS TEP/ TSP - SERIES 50Hz

P U M P S. The quality standard for hydraulic efficiency and suction lift. PERIPHERAL PUMPS TEP/ TSP - SERIES 50Hz P U M P S THE BENCHMARK FOR PERFORMANCE The quality standard for hydraulic efficiency and suction lift. PERIPHERAL PUMPS TEP/ TSP - SERIES 5Hz I N D E X TEP / TSP / TRP SERIES - PERIPHERAL PUMPS Page

More information

LES. Single-stage end-suction pumps Identification Type key

LES. Single-stage end-suction pumps Identification Type key Contents Singlestage endsuction pumps Identification Type key Product data Introduction Applications Features and benefits Performance range pole pole 6 pole Construction Sectional drawing Construction

More information

The FLUX F 430 with mechanical seal

The FLUX F 430 with mechanical seal The FLUX F 0 with mechanical seal Flexible coupling between motor and pump The pump must be used with many varying liquids, consequently the smallest residual left within the pump is unacceptable. You

More information

DEBEM IM VERTICAL CENTRIFUGAL PUMPS.

DEBEM IM VERTICAL CENTRIFUGAL PUMPS. IM VERTICA CENTRIFUGA PUMPS The IM series of resin-encased vertical centrifugal pumps features high-performance pumps for fixed installations with pump immersed directly in the tank and operated by a directdrive

More information

PiB Series. PiB (Pump-in-a-Box) 4380 & 4392 Series

PiB Series. PiB (Pump-in-a-Box) 4380 & 4392 Series PiB Series PiB (Pump-in-a-Box) & 9 Series FILE NO: - DATE: July SUPERSEDES: - DATE: January 09 PiB Series Guaranteed In Stock At The Right Price! The PiB series builds on the high quality and unsurpassed

More information

IBV Series C Carbon Steel Inverted Bucket Vertical Steam Trap

IBV Series C Carbon Steel Inverted Bucket Vertical Steam Trap Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

IBV Series Z Alloy Steel Inverted Bucket Vertical Steam Trap

IBV Series Z Alloy Steel Inverted Bucket Vertical Steam Trap Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

Prima range. Alifter range. magnetical driven pumps in thermoplastic materials TMP TMA. centrifugal. self-priming

Prima range. Alifter range. magnetical driven pumps in thermoplastic materials TMP TMA. centrifugal. self-priming Prima range TMP centrifugal Alifter range magnetical driven pumps in thermoplastic materials TMA self-priming Prima - Alifter In this catalog Argal proposes the range of PRIMA pumps, magnetical driven,

More information

Thermal oil. Hot Water Pumps. Fields of Application

Thermal oil. Hot Water Pumps. Fields of Application Type Series ooklet 0.50 G3 Etanorm SY Thermal Oil / Hot Water Pumps Fields of pplication Etanorm SY pumps are used in heat transfer systems (DIN 75) or in hot water circulation systems. Operating Data

More information

ISO 9906 INTERNATIONAL STANDARD. Rotodynamic pumps Hydraulic performance acceptance tests Grades 1 and 2

ISO 9906 INTERNATIONAL STANDARD. Rotodynamic pumps Hydraulic performance acceptance tests Grades 1 and 2 INTERNATIONAL STANDARD ISO 9906 First edition 1999-1-15 Rotodynamic pumps Hydraulic performance acceptance tests Grades 1 and Pompes rotodynamiques Essais de fonctionnement hydraulique pour la réception

More information

TPH Series 50Hz Multi-stage Centrifugal Pump

TPH Series 50Hz Multi-stage Centrifugal Pump WLRUS PUMP T Series Hz Multistage Centrifugal Pump ll specifications are subject to change without notice. 9 T Product data pplications Page Standard mode Page Operation conditions Page Pump construction

More information

Globe Valve, Metal. Sectional drawing. *see information on working medium on page 2

Globe Valve, Metal. Sectional drawing. *see information on working medium on page 2 Globe Valve, Metal Construction The GEMÜ pneumatically operated /-way valve has a robust low maintenance aluminium actuator. The valve spindle is sealed by a self-adjusting gland packing providing low

More information

FLUID MECHANICS D203 SAE SOLUTIONS TUTORIAL 2 APPLICATIONS OF BERNOULLI SELF ASSESSMENT EXERCISE 1

FLUID MECHANICS D203 SAE SOLUTIONS TUTORIAL 2 APPLICATIONS OF BERNOULLI SELF ASSESSMENT EXERCISE 1 FLUID MECHANICS D203 SAE SOLUTIONS TUTORIAL 2 APPLICATIONS OF BERNOULLI SELF ASSESSMENT EXERCISE 1 1. A pipe 100 mm bore diameter carries oil of density 900 kg/m3 at a rate of 4 kg/s. The pipe reduces

More information

BNA Series. PLENUM FAN with Backward Wheels

BNA Series. PLENUM FAN with Backward Wheels BNA Series PLENUM FAN with Backward Wheels BNA Series BNA Series Plenum Fans Backward wheels Kruger Plenum Fans are designed for air handling applications where the fan operates unhoused within a plenum.

More information

DBS315 1-phase SIDE CHANNEL BLOWERS

DBS315 1-phase SIDE CHANNEL BLOWERS DBS15/ 1-phase DESCRIPTION Dutair blowers for pressure and vacuum are compact machines consisting of an electric motor with a built-on pump housing. The rotational speed of the impeller creates a high

More information

CENTRIFUGAL PUMP SELECTION, SIZING, AND INTERPRETATION OF PERFORMANCE CURVES

CENTRIFUGAL PUMP SELECTION, SIZING, AND INTERPRETATION OF PERFORMANCE CURVES CENTRIFUGAL PUMP SELECTION, SIZING, AND INTERPRETATION OF PERFORMANCE CURVES 4.0 PUMP CLASSES Pumps may be classified in two general types, dynamic and positive displacement. Positive displacement pumps

More information

WTS Table of contents. Layout

WTS Table of contents. Layout Table of contents Thermal and hydraulic design of shell and tube heat exchangers... 2 Tube sheet data... 4 Properties of Water and Steam... 6 Properties of Water and Steam... 7 Heat transfer in pipe flow...

More information

Direct-operated 2/2-way solenoid valves Type EV210B

Direct-operated 2/2-way solenoid valves Type EV210B Data sheet Direct-operated 2/2-way solenoid valves Type EV20B EV20B covers a wide range of direct-operated 2/2-way solenoid valves for universal use. EV20B is a very robust valve program with high performance

More information

Made in Italy HOSE REELS CATALOGUE TECHNOLOGY FOR FLUIDYNAMICS. No. E14/A1

Made in Italy HOSE REELS CATALOGUE TECHNOLOGY FOR FLUIDYNAMICS. No. E14/A1 Made in Italy HOSE REELS CATALOGUE TECHNOLOGY FOR FLUIDYNAMICS No. E14/A1 The complete range of our products is presented in the specific catalogues: HOSE REELS CATALOGUE No. E14/A2 HOSE REELS CATALOGUE

More information

EXPLODED DIAGRAM - PARTS VIEW

EXPLODED DIAGRAM - PARTS VIEW Power Supply Sales Model: KSIL018-H216-I 208-230V~ / 1ph / 60Hz EXPLODED DIAGRAM - PARTS VIEW This information is to be used by qualify AC technicians only KSIL1816- Drawing No. D2IL16181301 Above information

More information

CMA - B - C - D - CMR

CMA - B - C - D - CMR Cast iron self-priming electric pumps. APPLICATIONS Pressure boosting domestic plants Small-scale irrigation Moving non-aggressive liquids for civil and industrial use Washing plants Washing vehicles CMA-B-C-D

More information

ALUMINIUM CENTRIFUGAL FANS. 4 x M6 x OUTLET x M6 x 20

ALUMINIUM CENTRIFUGAL FANS. 4 x M6 x OUTLET x M6 x 20 DESCRIPTION Dutair LK-series industrial ventilators consist of a robust body made from die-cast aluminium alloy. Impellers are made of extruded aluminium. The asynchronous electric motors are maintenance

More information

ALUMINIUM CENTRIFUGAL FANS x M6 x x M6 x 16

ALUMINIUM CENTRIFUGAL FANS x M6 x x M6 x 16 LK4 DESCRIPTION Dutair LK-series industrial ventilators consist of a robust body made from die-cast aluminium alloy. Impellers are made of extruded aluminium. The asynchronous electric motors are maintenance

More information

Centrifugal Machines Table of Contents

Centrifugal Machines Table of Contents NLNG Course 017 Table of Contents 1 Introduction and Basic Principles... 1.1 Hydraulic Machines... 1.... 1.3 Pump Geometry... 1.4 Pump Blade Geometry...3 1.5 Diffusers...5 1.6 Pump Losses...6 1.7 Example

More information

ALUMINIUM CENTRIFUGAL FANS. 4 x M6 x 16

ALUMINIUM CENTRIFUGAL FANS. 4 x M6 x 16 DESCRIPTION Dutair BCT-series aluminium centrifugal fans with open die-cast aluminium impellers and forward curved blades are suitable for material transport and high pressure applications. The asynchronous

More information

ALUMINIUM CENTRIFUGAL FANS M20 4 x M5 x 10 INLET. 4 x M5 x 12

ALUMINIUM CENTRIFUGAL FANS M20 4 x M5 x 10 INLET. 4 x M5 x 12 BCT61 DESCRIPTION Dutair BCT-series aluminium centrifugal fans with open die-cast aluminium impellers and forward curved blades are suitable for material transport and high pressure applications. The asynchronous

More information

Ball screw. Linear. Coupling cover. 1Positioning table of a structure with enhanced sealing property. 3 High corrosion resistance

Ball screw. Linear. Coupling cover. 1Positioning table of a structure with enhanced sealing property. 3 High corrosion resistance Cleanroom Precision Positioning Table TC Ball screw TC EB Slide table inear Way Side cover Stainless sheet Motor bracket inear Coupling cover Pipe threads for suction connector Points ight weight, low

More information

CME / CM-GE / DCME IN-LINE CONSTANT PRESSURE PUMPS. TECHNICAL DATA - CME/CM-GE single flanged

CME / CM-GE / DCME IN-LINE CONSTANT PRESSURE PUMPS. TECHNICAL DATA - CME/CM-GE single flanged CIRCUTORS ND IN-INE UMS ENERGY EFFICIENCY Circulation pups with in-line ports, suitable for installation in heating and air conditioning, refrigeration, and doestic hot water systes. Extreely versatile

More information

External gear pump Type G3, Series 3X

External gear pump Type G3, Series 3X NS to 5 External gear pump Type G3, Series 3X Up to 2 bar Up to 5.2 cm 3 RE 039/07.00 Replaces: 03.00 Plain bearings for high loads Mono-block bearing New principle of hydrostatic gap compensation Drive

More information

CNA-CNB. Centrifugal fans

CNA-CNB. Centrifugal fans NA-NB entrifugal fans Product facts Product Single-inlet low-pressure fans with backward-curved blades. Use In industrial ventilation systems for uncontaminated, non-corrosive air, max. 70 º, where a low

More information

VDN2.. VEN2.. VUN2.. Radiator valves. Building Technologies HVAC Products ACVATIX TM. NF norm, for 2-pipe heating systems

VDN2.. VEN2.. VUN2.. Radiator valves. Building Technologies HVAC Products ACVATIX TM. NF norm, for 2-pipe heating systems 06 EN - Straight valves VDN.. Angle valves VEN.. Reverse angle valves VUN.. ACVATIX TM Radiator valves NF norm, for -pipe heating systems VDN.. VEN.. VUN.. Valve bodies made of brass, mat nickel-plated

More information

TECHNICAL INFORMATION Bulletin

TECHNICAL INFORMATION Bulletin Peerless Pump Company 005 Dr..L. King Jr. Street, P.O. Box 706, Indianapolis, IN 4607-706, USA Telephone: (17) 95-9661 Fax: (17) 94-78 www.peerlesspump.com www.epumpdoctor.com TECHNICAL INFORATION Bulletin

More information

SINGLE IMPELLER CENTRIFUGAL ELECTRIC PUMPS in cast iron

SINGLE IMPELLER CENTRIFUGAL ELECTRIC PUMPS in cast iron Cast iron self-priming electric pumps. APPLICATIONS Pressure boosting domestic plants Small-scale irrigation Moving non-aggressive liquids for civil and industrial use Washing plants Washing vehicles CMA-B-C-D

More information

PW type vacuum pumps and DW type blowers

PW type vacuum pumps and DW type blowers PW type vacuum pumps and DW type blowers 01/2016 CONTENTS Contents Application... 2 Principle of Operation. Construction... 2 Operating parameters... 3 General terms of characteristics validity... 3 Exploitation

More information

Pumping Stations Design For Infrastructure Master Program Engineering Faculty-IUG

Pumping Stations Design For Infrastructure Master Program Engineering Faculty-IUG umping Stations Design For Infrastructure Master rogram Engineering Faculty-IUG Lecture : umping Hydraulics Dr. Fahid Rabah Water and environment Engineering frabah@iugaza.edu The main items that will

More information

NM, NMD 60 Hz NM, NMD. Close Coupled Centrifugal Pumps with threaded ports

NM, NMD 60 Hz NM, NMD. Close Coupled Centrifugal Pumps with threaded ports , D z Close Coupled Centrifugal ups Construction Close-coupled, centrifugal pups; electric otor with extended sha directly connected to the pup. : single-ipeller D: with two back-to-back ipellers (with

More information

CV3000 Series. Characterized Insert Control Valves

CV3000 Series. Characterized Insert Control Valves CV3000 Series Characterized Insert Control Valves The CV3000 Series is a v-type control valve for precise control allowing high pressure drop capability with straight-through flow and bubble-tight shut

More information

by Dr. Shibayan Sarkar Department of Mechanical Engineering

by Dr. Shibayan Sarkar Department of Mechanical Engineering Lecture on Pump by Dr. Shibayan Sarkar Department of Mechanical Engineering Indian School of Mines Dhanbad WHAT IS PUMP? A hydrodynamic pump machine is a device which converts the mechanical energy held

More information

GRUNDFOS DATA BOOKLET MAGNA, UPE. Series 2000 circulator pumps

GRUNDFOS DATA BOOKLET MAGNA, UPE. Series 2000 circulator pumps GRUNDFOS DATA BOOKLET Series circulator pumps Contents Product data MAGNA and UPE 3 Duty range 3 Characteristic features 3 Benefits 3 Applications 3 eating systems 3 Pumped liquids 3 Type key Performance

More information

98 Series Backpressure Regulators and Relief Valves

98 Series Backpressure Regulators and Relief Valves 9 Series Backpressure Regulators and Relief Valves Bulletin.:9 November 09 W TYPE 9H W TYPE 9LD Figure. Typical 9 Relief Valves Introduction W TYPE 9HD The 9 Series (Figure ) is used for backpressure or

More information

MODEL: WB009GMFI19HLD (120V) Wall Mount DC Inverter Fan Coil Unit 9,000 BTUH

MODEL: WB009GMFI19HLD (120V) Wall Mount DC Inverter Fan Coil Unit 9,000 BTUH MODEL: WB009GMFI19HLD (120V) Wall Mount DC Inverter Fan Coil Unit 9,000 BTUH No. Part Name Quantity BOM code List Price Remark 1 Panel assembly 1 201132890609 2 Air filter 2 201132890704 5 Display box

More information

Direct-operated 2/2-way compact solenoid valves Type EV210A

Direct-operated 2/2-way compact solenoid valves Type EV210A Data sheet Direct-operated 2/2-way compact solenoid valves Type EV210A EV210A covers a wide range of small, directoperated 2/2-way solenoid valves for use in industrial machinery. The compact design together

More information

Samos SI E1/E2

Samos SI E1/E2 Samos SI E/E Samos SI E Description Busch Samos SI regenerative blowers are designed for either pressure or vacuum. They are available in single and two stage models so they can operate over a wide range

More information

DG SERIES BOILER WATER SUPPLY PUMP [PRODUCT CATALOG 2010] Inosculating innovative technologies, interpreting the art of fluid!

DG SERIES BOILER WATER SUPPLY PUMP [PRODUCT CATALOG 2010] Inosculating innovative technologies, interpreting the art of fluid! DG DG SERIES BOILER WATER SUPPLY PUMP [PRODUCT CATALOG 0] Inosculating innovative technologies, interpreting the art of fluid! DG DG Series middle and low pressure, hypo-high-pressure boiler water supply

More information

Centrifugal Pumps. Problem 1. This is a small project having three parts: Parts (a), (b), and (c).

Centrifugal Pumps. Problem 1. This is a small project having three parts: Parts (a), (b), and (c). 7 Centrifugal Pumps Problem 1 This is a small project having three parts: Parts (a), (b), and (c). Part (a): Enlist the design parameters and performance parameters of a centrifugal pump. Explain, to the

More information

Single Phase Motors Technical Datasheets

Single Phase Motors Technical Datasheets Single Phase Motors Technical Datasheets EN A dynamic, strong and ambitious Group: Orange1 Holding is an international renown Group, one of the most important European manufacturers of single-phase and

More information

Front flange FLV. Max. [knm/stroke]

Front flange FLV. Max. [knm/stroke] SDN 45 Safety shock absorbers SDN are a low cost alternative to industrial shock absorbers appropriate to customers requirements. Typical applications: cranes, storage and retrieval unit for highbay warehouse,

More information

Solenoid valves Type EVUL

Solenoid valves Type EVUL Data sheet Solenoid valves EVUL EVUL solenoid valves are designed to fit into compact refrigeration systems. Available in servo operated versions they can be applied in liquid, suction, and hot gas lines.

More information

Series 3000 and XE-Series Engineering Data

Series 3000 and XE-Series Engineering Data Series 3000 and XE-Series Engineering Data A C A U S T R A L I A Series 3000 and XE-Series Engineering Data The NEW era of Series 3000 and XE-Series Cooling Towers continue to exceed the industry standard

More information

CHAPTER TWO CENTRIFUGAL PUMPS 2.1 Energy Transfer In Turbo Machines

CHAPTER TWO CENTRIFUGAL PUMPS 2.1 Energy Transfer In Turbo Machines 7 CHAPTER TWO CENTRIFUGAL PUMPS 21 Energy Transfer In Turbo Machines Fig21 Now consider a turbomachine (pump or turbine) the total head (H) supplied by it is The power delivered to/by the fluid simply

More information

Chapter Four Hydraulic Machines

Chapter Four Hydraulic Machines Contents 1- Introduction. - Pumps. Chapter Four Hydraulic Machines (لفرع الميكانيك العام فقط ( Turbines. -3 4- Cavitation in hydraulic machines. 5- Examples. 6- Problems; sheet No. 4 (Pumps) 7- Problems;

More information

CROSS FLOW COOLING TOWER

CROSS FLOW COOLING TOWER CROSS FLOW COOLING TOWER LUCKY GREEN THAI INDUSTRIES CO LTD Material Specification Model LGX 80 00 0 00 0 300 30 400 00 600 700 800 000 Motor Totally enclosed Totally enclosed fan cooled Driving System

More information

Solenoid valves 2/2-way direct-operated type EV210A

Solenoid valves 2/2-way direct-operated type EV210A MAKING MODERN LIVING POSSIBLE Data sheet Solenoid valves 2/2-way direct-operated type EV210A EV210A covers a wide range of small, direct-operated 2/2-way solenoid valves for use in industrial machinery.

More information

GRUNDFOS DATA BOOKLET MAGNA, UPE. Series 2000 circulator pumps

GRUNDFOS DATA BOOKLET MAGNA, UPE. Series 2000 circulator pumps GRUNDFOS DATA BOOKLET MAGNA, UPE Series circulator pumps Contents Product data MAGNA and UPE 3 Duty range 3 Characteristic features 3 Benefits 3 Applications 3 eating systems 3 Pumped liquids Type key

More information

IJREAS Volume 2, Issue 2 (February 2012) ISSN:

IJREAS Volume 2, Issue 2 (February 2012) ISSN: DESIGN AND CFD ANALYSIS OF SINGLE STAGE, END SUCTION, RADIAL FLOW CENTRIFUGAL PUMP FOR MINE DEWATERING APPLICATION Swapnil Urankar * Dr. H S Shivashankar ** Sourabh Gupta *** ABSTRACT Heavy centrifugal

More information

LMP 210. Style B. Style S. Maximum pressure 60 bar F l o w r a t e s t o l / m i n

LMP 210. Style B. Style S. Maximum pressure 60 bar F l o w r a t e s t o l / m i n LMP 0 Style S Style Maximum pressure 60 bar F l o w r a t e s t o 7 0 l / m i n 6 Technical data Filter housing (Materials) Head: luminium Housing: nodised luminium ypass valve: Nylon - Steel Pressure

More information

GRUNDFOS DATA BOOKLET MAGNA, UPE. Series 2000 circulator pumps

GRUNDFOS DATA BOOKLET MAGNA, UPE. Series 2000 circulator pumps GRUNDFOS DATA BOOKLET MAGNA, UPE Series circulator pumps Contents Product data MAGNA/UPE 3 Duty range 3 Characteristic features 3 Benefits 3 Applications 3 eating systems 3 Pumped liquids 3 Type key Performance

More information

Suction fi lters. SF series. Flow rate up to 160 l/min. Suction fi lters

Suction fi lters. SF series. Flow rate up to 160 l/min. Suction fi lters Suction fi lters SF 00 series Flow rate up to 60 l/min Suction fi lters FILTER SIZING The correct filter sizing have to be based on the variable pressure drop depending by the application. For example,

More information

CHAPTER 12 Turbomachinery

CHAPTER 12 Turbomachinery CAER urbomachinery Chapter / urbomachinery 800 / 0 8 8 rad /s, u r 8 8 0 0 m /s, u r 8 8 0 0 8 m /s, rbv, but V u since, n n 0 0 0 0 0 0 m / s V V 0 0 m /s, rb 0 0 0 Vn u 0 8 6 77 m /s, tan tan 0 n t V

More information

Chapter Four Hydraulic Machines

Chapter Four Hydraulic Machines Contents 1- Introduction. 2- Pumps. Chapter Four Hydraulic Machines (لفرع الميكانيك العام فقط ( Turbines. -3 4- Cavitation in hydraulic machines. 5- Examples. 6- Problems; sheet No. 4 (Pumps) 7- Problems;

More information

JETINOX SELF-PRIMING CENTRIFUGAL ELECTRIC PUMPS

JETINOX SELF-PRIMING CENTRIFUGAL ELECTRIC PUMPS JETINOX SELF-RIMIN ENTRIFUL ELETRI UMS TENIL DT Operating range: fro. to 1. /h with head up to etres. Liquid quality requireents: clean, free fro solid or abrasive containants, non-viscous, non-aggressive,

More information

JET SELF-PRIMING CENTRIFUGAL PUMPS DIMENSIONS AND WEIGHTS JET JET

JET SELF-PRIMING CENTRIFUGAL PUMPS DIMENSIONS AND WEIGHTS JET JET JET SELFRIMING CENTRIFUGL UMS JET M JET T JET M JET T JET M JET T JET M JET T JET M JET T JET M JET T JET M JET T JET M JET T JET M JET T JET M JET T VOLTGE z x V~ x V~ x V~ x V~ x V~ x V~ x V~ x V~ x

More information

Fast and Ultimate Vibration Field Solution: From Problem Detection to Field Performance Validation

Fast and Ultimate Vibration Field Solution: From Problem Detection to Field Performance Validation Fast and Ultimate Vibration Field Solution: From Problem Detection to Field Performance Validation Giancarlo CICATELLI Flowserve - Italy Bruno SCHIAVELLO Flowserve Corporation - USA First Middle East Turbomachinery

More information

End Suction Centrifugal Pumps

End Suction Centrifugal Pumps C.R.I. PUMPS End Suction Centrifugal Pumps E C W S E R I E S An ISO 9001 & ISO 14001 Company C.R.I. PUMPS Vision, Mission and Values To be the industry leader providing best - in - class fluid management

More information

Prof. Dr.-Ing. F.-K. Benra. ISE Bachelor Course

Prof. Dr.-Ing. F.-K. Benra. ISE Bachelor Course University Duisburg-Essen Campus Duisburg Faculty of Engineering Science Department of Mechanical Engineering Name Matr.- Nr. Examination: Fluid Machines Examiner: Prof. Dr.-Ing. F.-K. Benra Date of examination:

More information

ELECTRONIC CIRCULATORS FOR HEATING AND COOLING SYSTEMS. ErP. eady

ELECTRONIC CIRCULATORS FOR HEATING AND COOLING SYSTEMS. ErP. eady ELECTRONIC CIRCULATORS OR EATING AND COOLING SYSTEMS ErP eady TECNICAL DATA EVOSTA 2 WET ROTOR ELECTRONIC CIRCULATORS Operating range:,-3,6 m 3 /h with head up to 6,9 metres. Pumped liquid temperature

More information

Fachgesprach 12. HVAC Pumps. For Project Managers

Fachgesprach 12. HVAC Pumps. For Project Managers Fachgesprach 12 HVAC Pumps For Project Managers WTF Philosophy: If you don t remember a certain formula, it's OK - you can always GoogleTheS h i t. But bad engineering CONCEPTS can hurt you. WTF Institute

More information

143 EEX gerotor pump unit. For use in oil circulation systems in gas- and dust-ex-atmospheres

143 EEX gerotor pump unit. For use in oil circulation systems in gas- and dust-ex-atmospheres 1 EEX gerotor pump unit For use in oil circulation systems in gas- and dust-ex-atmospheres Gerotor pump series 1 EEX The 1 EEX product series has been specifically designed for centralized lubrication

More information

Pneumatic Universal. Actuator MOTORIZED VALVES USE TECHNICAL FEATURES OF THE ACTUATOR. Data sheet

Pneumatic Universal. Actuator MOTORIZED VALVES USE TECHNICAL FEATURES OF THE ACTUATOR. Data sheet Data sheet. - 8 USE The motorized valve is specifically used for the interception and regulation of fluids in: systems using alternative energy industrial systems in general using hot and cold fluids automation

More information

Flow Structure Investigation in the Lateral Inlet Branches of Hydraulic Machines and Some Recommendations on Their Designing

Flow Structure Investigation in the Lateral Inlet Branches of Hydraulic Machines and Some Recommendations on Their Designing Available online at www.sciencedirect.com Procedia Engineering 39 (2012 ) 140 147 XIIIth International Scientific and Engineering Conference HERVICON-2011 Flow Structure Investigation in the Lateral Inlet

More information

SHORTCUT CALCULATIONS AND GRAPHICAL COMPRESSOR SELECTION PROCEDURES

SHORTCUT CALCULATIONS AND GRAPHICAL COMPRESSOR SELECTION PROCEDURES APPENDIX B SHORTCUT CALCULATIONS AND GRAPHICAL COMPRESSOR SELECTION PROCEDURES B.1 SELECTION GUIDE FOR ELLIOTT MULTISTAGE CENTRIFUGAL COMPRESSORS* * Reprinted from a 1994 Elliott Company sales bulletin.

More information

Conductivity sensor for hygienic applications

Conductivity sensor for hygienic applications Conductivity sensor for hygienic applications Type 8221 can be combined with Perfect for demanding applications in the hygienic industry (CIP and SIP compatible) Variants available for usage over a wide

More information

Prof. Dr.-Ing. F.-K. Benra. ISE batchelor course

Prof. Dr.-Ing. F.-K. Benra. ISE batchelor course University Duisburg-Essen Campus Duisburg Faculty of engineering Science Department of Mechanical Engineering Examination: Fluid Machines Examiner: Prof. Dr.-Ing. F.-K. Benra Date of examination: 06.03.2006

More information

60 Hz. e-nsc Series HORIZONTAL CENTRIFUGAL ELECTRIC PUMPS EQUIPPED WITH IE3 MOTORS

60 Hz. e-nsc Series HORIZONTAL CENTRIFUGAL ELECTRIC PUMPS EQUIPPED WITH IE3 MOTORS 6 Hz e-nsc Series HORIZONTAL CENTRIFUGAL ELECTRIC PUMPS EQUIPPED WITH IE3 MOTORS Cod. 19112831 Rev. B Ed.7/217 Xylect TM Xylect TM is a pump solution software with an extensive online database of product

More information

E 094 E 103 E 143. Tank top mounting Connection up to G1 Nominal flow rate up to 135 l/min e

E 094 E 103 E 143. Tank top mounting Connection up to G1 Nominal flow rate up to 135 l/min e R e t u r n F i l t e rs E 094 E 103 E 143 Tank top mounting Connection up to G1 Nominal flow rate up to 135 l/min 20.30-5e D e s c r i p t i o n Application In the return line circuits of hydraulic systems.

More information

CONNECTION DESIGN. Connections must be designed at the strength limit state

CONNECTION DESIGN. Connections must be designed at the strength limit state CONNECTION DESIGN Connections must be designed at the strength limit state Average of the factored force effect at the connection and the force effect in the member at the same point At least 75% of the

More information

AC axial compact fan

AC axial compact fan ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-7467 Mulfingen Phone +49 798 8-0 Fax +49 798 8-0 info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen County court Stuttgart HRA

More information

ABB SpA COMEM Operating Unit Strada Regionale 11, Signolo Montebello Vicentino (VI) - ITALY

ABB SpA COMEM Operating Unit Strada Regionale 11, Signolo Montebello Vicentino (VI) - ITALY ABB SpA COMEM Operating Unit Strada Regionale 11, Signolo 22 36054 Montebello Vicentino (VI) - ITALY www.abb.com/transformercomponents The information contained in this document is for general information

More information

Tangential Fans Series TW Impeller diameter 150 mm and 200 mm

Tangential Fans Series TW Impeller diameter 150 mm and 200 mm Tangential Fans Series TW Impeller diameter mm and 0 mm 105 Corporate Drive, Suite E Spartanburg, SC 293 PO Box 2889, Spartanburg, SC 294 USA Tel: 864-599-63 Fax: 864-599-6344 e-mail: info@ltg-inc.net

More information

Design of Monoblock Centrifugal Pump Impeller

Design of Monoblock Centrifugal Pump Impeller Design of Monoblock Centrifugal Pump Impeller Authors Mr. Chetan Kallappa Tambake 1, Prof. P. V. Salunke 1 Department of Mechanical Engineering, Walchand Institute of Technology, Ashok Chowk, Solapur-413006,

More information

e-mp Series MPA, MPR, MPD, MPV Lenntech 50 Hz Tel Fax

e-mp Series MPA, MPR, MPD, MPV Lenntech 50 Hz Tel Fax Hz e-mp Series MPA, MPR, MPD, MPV HIGH PRESSURE MULTISTAGE PUMPS ACCORDING TO ISO 199 Lenntech info@lenntech.com Tel. +31-1-1-9 www.lenntech.com Fax. +31-1-1-9 Cod. 1911 Rev. A Ed.3/17 Xylect TM Xylect

More information