Y1SA Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

Size: px
Start display at page:

Download "Y1SA Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS"

Transcription

1 TEHNIAL SPEIFIATIONS Y1SA Series EarthDirEX Geothermal Direct Geoexchange Heat Pump ooling capacity,000 to 0,000 Heating capacity 1,000 to,000 EER 19.0 to.0 and OP.8 to.0 The Y1SA Geothermal heat pump, Earth loops and air handler are an incredibly quiet and efficient way to heat and cool your home or business. ecause we are using the natural energy from the Earth, you can reduce your electric/utility bill by as much as 0%. FEATURES and ENEFITS Single Stage - opeland Scroll compressor Electronic Expansion Valve one valve for precise refrigerant control in all modes of operation Interface ontrol oard Two digit LED provides system operation, status and diagnostic information. Diagnostic: 1 event/fault codes provide troubleshooting information System Protection: Internal controls monitor system operation to protect the compressor. Three Minute Restart Time Delay: When the unit shuts down, a delay keeps the unit from restarting, eliminating the highest cause for compressor failure. Micro-hannel Indoor coil is all aluminum designed to optimize heat transfer, minimize size and cost, and increase durability and reliability. Earth Loop Seal Valve on & ton captures refrigerant in the outdoor Earth loop during off mode, complies with ASHRAE Standard 1 Oil Separator - 99% efficient and has an internal filter, installed at the factory. A second filter (shipped with the unit) is to be used as a replacement in to 8 hours Hot Gas ypass Injected into evaporator to prevent freeze up Accumulator Protection from liquid flood back and future compressor failures. Sight Glass- Included for simple indication of proper refrigerant change. Sound lanket Is standard equipment Energy Efficient rushless D lower Motor - EM constant torque in all models Improve aesthetics of your home - No exposed or noisy outdoor equipment Simpler System - Our EarthDirEX geothermal systems do not use a water to refrigerant heat exchanger, or a pump to circulate the water

2 DIMENSIONS.1. Line Voltage onnections Low Voltage onnections Liquid Line to Air Handler Vapor Line to Air Handler.0 Vapor Line to Earth Loop Liquid Line to Earth Loop OMPONENTS ontrol oard LED Diagnostic Low Voltage Terminal Strip ontactor Accumulator Electric ox over Oil Separator Relay Small Valve Large Valve Small Valve heck Valve Solenoid Valve & oil EXV Valve & oil ompressor Hot Gas Valve & oil Reversing Valve

3 FIGURES & TALES / / / 1 11/8 K.O. (typ.) A 1 /8" K.O. /8 /8 1 /8 /8 11/ 1/8 1/8 11/8 K.O. (typ.) 1/ K.O. (typ.) 11/ 1/ 1 /8 1 1/8 /8" K.O. DETAIL D H 1/ 1/ SUTION LIQUID 1 1/ 1 W " AINET SIZE H W A DETAIL D Tall 9-/ /1 18-1/ No -1/1 -/1 1 Yes

4 AINET SIZE SWITH SETTINGS OOLING OR HEATING AIRFLOW (FM & L/s) 0 = OFF, 1 = ON DRY OIL ESP (INHES) DRY OIL ESP (M) 1/ / / / NOTE: When matched with two-stage outdoor units, the airflow on low (Y1 or W1) input will be 0% of the values shown in this table. Table 1. Airflow Data for EM Air Handlers (E,V)M MINIMUM AMPAITY & MAXIMUM OVERURRENT PROTETION 0 VA, 0 & 0 HZ, SINGLE PHASE 08 VA, 0 & 0 HZ, SINGLE PHASE MA MOP MA MOP AINET APAITY HEAT KIT MODEL NUMER HHK- A SINGLE A SINGLE A SINGLE A SINGLE 0 NONE H-XX H-XX H-XX H-XX H-XX Q-XX Q-XX NONE H-XX H-XX H-XX H-XX H-XX H-XX H-XX Q-XX Q-XX Table. (E,V)M Minimum ircuit Ampacity & Maximum Overcurrent Protection

5 ELETRIAL AND PHYSIAL DATA Physical Data ompressor Data GEOTHERMAL SYSTEM Y1SA-EK ( TON) Y1SA-EK ( TON) Y1SA-E8K ( TON) Y1SA-E0K ( TON) Length (L) Width (W).... Height (H) Weight Volts-ycles-Phase (1) 08/0V, 1phase, 0Hz Min. ircuit Ampacity (MA) Max. Overcurrent Protection (MOP) 0 Rated Load Amps (RLA) Locked Rotor Amps (LRA) Air Handler Match EMMNK- EMMNK- EMMN0K- EMMN0K- Filter Size (Field Supplied) 18 x 0 x 1 18 x 0 x 1 0 x 0 x 1 0 x 0 x 1 Refrigerant Vapor Line O.D. (oth to air handler and earth loop) Liquid Line O.D. (oth to air handler and earth loop) / / /8 /8 1/ 1/ 1/ 1/ Unit is shipped from factory with nitrogen holding charge. REOMMENDED INITIAL R10-A HARGES WELL LENGTH (FT.) TON TON TON TON R-10A HARGE OZ. (LS) WELL LENGTH (FT.) R-10A HARGE OZ. (LS) WELL LENGTH (FT.) R-10A HARGE OZ. (LS) WELL LENGTH (FT.) R-10A HARGE OZ. (LS) 00 9 (9.) 8 (.) 00 1,1 (8) 00 1,1 (8) 1 9 (.) 0 9 (.) 1,1 (0.8) 1,1 (0.8) (19.9) 00 8 (. 80 1,0 () (x) 0* 1, (9) NOTES: The charge amounts shown above are for total system initial charge. * When -0 ft Earth Loops are used, refrigerant distributors are required, one for vapor and one for liquid line. (See Earth Loops next page). MODEL IDENTIFIATION ODES EX: Y1SA Y 1 S A - E K Y = Geothermal Heat Pump Design Series S = Split A = Single Stage EXV K = 08/0-1-0 E = 0/0-1-0 Nominal apacity

6 MATH UP AND APAITIES omp. Section Air Handler ooling EER Heating OP FM Y1SA-EK EMMNK-,000 1, Y1SA-EK EMMNK-,000 1, Y1SA-E8K EMMN0K- 8,000 0, Y1SA-E0K EMMN0K- 0,000 19, EARTH LOOPS Size/Length /0 (1) (1) Use part #100 distributor for vapor lines / - / to /8, part #100 distributor for vapor lines / - / to /, and part #100 for liquid line 1/. DIRET GEOEXHANGE EARTH LOOPS SKU Length Vapor Liquid 9 10 ft / / ft / / ft / / ft / / ft /8 /8 9 ft /8 / ft /8 /8 Earth Loop Design Length The sub-surface refrigerant lines used for geothermal heat exchange purposes must be sized to accommodate the maximum of the greater of the heating or cooling capacity design loads. Typically, in mostly non-porous rock or in permanently water saturated soil, an earth loop length between ft and 100 feet per ton (.-10.8m/kW) of capacity is required. Within the United States, see Figure 1 (page ) to help determine the appropriate earth loop length. For installations outside of the United States, the following rules will dictate the sizing of the earth loop. These rules assume that the earth loop will be installed within bedrock or permanently water saturated ground. For the building to be conditioned, calculate the annual heating and the annual cooling loads. Use AA Manual J or other locally recognized load calculation program. Annual ooling Load Annual Heating Load Earth Loop Needed (per Ton of System Size) Line Set Sizing between the ompressor Unit & Air Handler 1 ft 1 but ft > ft OMPRESSOR SIZE (TU)* Annual ooling Load Annual Heating Load LIQUID LINE Size of Unit (in tons) Annual ooling Load Annual Heating Load VAPOR LINE,000 -,000 1/ inch O.D. / inch O.D. 8,000-0,000 1/ inch O.D. /8 inch O.D. *ompressor size is the actual compressor size in the compressor unit box, not maximum system capacity, system size, or air handler size. Earth Loop Needed (per Ton of System Size, rounded up) Example 1,000,000 tons.8 ( ton x ft = 19 ft) 00 ft Example 8,000,000 tons 1.9 ( ton x 100 ft = 00 ft) 00 ft

7 Marine () Dry () Moist (A) Warm-Humid elow White Line NOTE: Zone includes all of Alaska except for the following burroughs in Zone 8: ethel, Northwest Arctic, Dellingham, Southeast Fairbanks, N. Star, Wade Hampton, Nome, Yukon-Koyukuk, North Slope. IE ZONES EARTH LOOP SIZE (FT/TON) 1,, A, 100, A, 80,,,, 8 1 NOTE: Zone 1 includes Hawaii, Guam, Puerto Rico, and the Virgin Islands There are exceptions to the earth loop sizes shown in this table. Within a climate zone, the weather, and underground conditions vary from place to place. The earth loop length may need to be adjusted accordingly. Earth loop size indicated in the table assumes installation within bedrock or permanently water saturated ground.

8 GENERAL TERMS OF LIMITED WARRANTY Nortek Global HVA, LL will furnish a replacement for any part of this product which fails in normal use and service within the terms and conditions of the warranty. For complete details of the Limited Warranty, including applicable terms and conditions, see your local installer or contact the Nortek Global HVA, LL warranty department for a copy. efore purchasing this appliance, read important energy cost and efficiency information available from your retailer. Specifications and illustrations subject to change without notice and without incurring obligations. Printed in U.S.A (0/01) 00E-01 (Replaces 00E-101)

ENVIRONMENTALLY SOUND R 410A REFRIGERANT

ENVIRONMENTALLY SOUND R 410A REFRIGERANT ENVIRONMENTALLY SOUND REFRIGERANT N4H3 Performance Series Product Specifications EFFICIENT 13 SEER HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase,

More information

B6VMAX Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

B6VMAX Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS TECHNICAL SPECIFICATIONS B6VMAX Series Air Handler with TXV 13-19 SEER Residential System 18,000-60,000 Btuh (Heat Pump & Air Conditioner) R-410A Refrigerant The B6VMAX Series of air handlers, when combined

More information

GB5BM Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Air Handler WARRANTY

GB5BM Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Air Handler WARRANTY TECHNICAL SPECIFICATIONS GB5BM Series Air Handler 13 SEER Residential System 18,000-60,000 Btuh (Heat Pump & Air Conditioner) The GB5BM Series of air handlers, when combined with our heat pump or air conditioner,

More information

EFFICIENT 13 SEER HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz

EFFICIENT 13 SEER HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz ENVIRONMENTALLY SOUND REFRIGERANT N4H3 Performance Series Product Specifications EFFICIENT 13 SEER HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase,

More information

ASPT Series. Multi-Position, Internal TXV. Air Handler 1½ to 5 Tons

ASPT Series. Multi-Position, Internal TXV. Air Handler 1½ to 5 Tons Series Multi-Position, Internal TXV Product Features Internal factory-installed thermal expansion valves for cooling and heat pump applications Direct drive, multi-speed ECM blower motor All-aluminum evaporator

More information

4HP13 PRODUCT SPECIFICATIONS 13 SEER SPLIT SYSTEM HEAT PUMP WARRANTY

4HP13 PRODUCT SPECIFICATIONS 13 SEER SPLIT SYSTEM HEAT PUMP WARRANTY 4HP13 PRODUCT SPECIFICATIONS 13 S SPLIT SYSTEM HEAT PUMP FORM NO. 4HP13-100 (07/2014) R410A Refrigerant High-quality condenser coil with copper tubing and enhanced louvered fin for maximum heat transfer

More information

Ductless Split Systems Floating Air

Ductless Split Systems Floating Air Ductless Split Systems Floating Air PURCHASER P.O. # DATE PROJECT LOCATION ENGINEER ARCHITECT SUBMITTED BY FOR APPROVAL FOR REFERENCE ITEM PLAN DESIGNATION QUANTITY COOLING BTU/H VOLTAGE FRIEDRICH MODEL

More information

GMVC8. ComfortNet -Compatible. Heating Input: 70, ,000 BTU/h. Two-Stage, Variable-Speed Gas Furnace

GMVC8. ComfortNet -Compatible. Heating Input: 70, ,000 BTU/h. Two-Stage, Variable-Speed Gas Furnace 80% AFUE Heating Input: 70,000 115,000 BTU/h ComfortNet -Compatible Two-Stage, Variable-Speed Gas Furnace Standard Features Aluminized steel, dual-diameter tubular heat exchanger Two-stage gas valve operates

More information

THE ENERGY 68,SAVING TDVI. exible Combine Modular 24, 26, 28, 30, 32, 34, 36, 38, 40, 42, 44 HP 60, 62, 64, 66 HP

THE ENERGY 68,SAVING TDVI. exible Combine Modular 24, 26, 28, 30, 32, 34, 36, 38, 40, 42, 44 HP 60, 62, 64, 66 HP I N V E RT E R ion Range exible Combine Modular TDV I TDV I TDV I INVERTER INVERTER INVERTER 14, 16, 18, 20, 22 HP TDV I 24, 26, 28, 30, 32, 34, 36, 38, 40, 42, 44 HP INVERTER INVERTER INVERTER TDV I INVERTER

More information

3 Port, 2-Ton Outdoor Heat Pump

3 Port, 2-Ton Outdoor Heat Pump Job Name: Tag# Submittal Data Sheet 3 Port, 2-Ton Outdoor Heat Pump 3MXS24NMVJU Efficiency SEER EER HSPF Non-Ducted 17.9 12.7 12.5 Ducted 14 9.7 8.2 Mixed 15.95 11.2 10.35 Performance Cooling (Btu/hr)

More information

ClimateMaster s Tranquility 22. Raj Hiremath Director of Residential Marketing

ClimateMaster s Tranquility 22. Raj Hiremath Director of Residential Marketing ClimateMaster s Tranquility 22 Raj Hiremath Director of Residential Marketing 1 CLIMATEMASTER Industry leader since 1950 s First to introduce 2-stage 27 EER unit First to introduce Outdoor split system

More information

Product Data. CAPVU Evaporator Coil A Coil --- Uncased Upflow, Downflow CAPVU

Product Data. CAPVU Evaporator Coil A Coil --- Uncased Upflow, Downflow CAPVU CAPVU Evaporator Coil A Coil --- Uncased Upflow, Downflow Product Data CAPVU A06002 The CAPVU evaporator coils incorporate proven standards for reliable system operation and performance throughout the

More information

DCG Commercial. 7½ - 12½ Ton Packaged Gas/ Electric Up to 11.3 EER / 80% AFUE

DCG Commercial. 7½ - 12½ Ton Packaged Gas/ Electric Up to 11.3 EER / 80% AFUE DG ommercial ½ - ½ Ton Packaged Gas/ Electric Up to. EER / 0% AUE ooling apacity:,000,000 BTU/h Heating apacity (Output):,000 BTU/h ontents Nomenclature... Product Specifications... Expanded ooling Data...

More information

Product Data CNPVP, CNPVT, CNPVU, CNRVU EVAPORATOR COIL N COIL - CASED AND UNCASED UPFLOW, DOWNFLOW

Product Data CNPVP, CNPVT, CNPVU, CNRVU EVAPORATOR COIL N COIL - CASED AND UNCASED UPFLOW, DOWNFLOW CNPVP, CNPVT, CNPVU, CNRVU EVPORTOR COIL N COIL - CSED ND UNCSED UPFLOW, DOWNFLOW Product Data CNPVP CNPVT (Transition) CN(P,R)VU 06008 06007 06004 This vertical design N -coil is a furnace coil designed

More information

Product Data. CNPVP, CNRVP, CNPVT, CNRVT, CNPVU, CNRVU Evaporator Coil N Coil Cased and Uncased Upflow, Downflow

Product Data. CNPVP, CNRVP, CNPVT, CNRVT, CNPVU, CNRVU Evaporator Coil N Coil Cased and Uncased Upflow, Downflow CNPVP, CNRVP, CNPVT, CNRVT, CNPVU, CNRVU Evaporator Coil N Coil Cased and Uncased Upflow, Downflow Product Data CN(P,R)VP CN(P,R)VT (Transition) A06008 A06007 This vertical design N -coil is a furnace

More information

Submittals. Advanced Series 1U09ES2VHA / AW09ES2VH* 1U12ES2VHA / AW12ES2VH* 1U18ES2VHA / AW18ES2VH* 1U24ES2VHA / AW24ES2VH* Rev.

Submittals. Advanced Series 1U09ES2VHA / AW09ES2VH* 1U12ES2VHA / AW12ES2VH* 1U18ES2VHA / AW18ES2VH* 1U24ES2VHA / AW24ES2VH* Rev. Submittals Advanced Series 1U09ES2VHA / AW09ES2VH* 1U12ES2VHA / AW12ES2VH* 1U18ES2VHA / AW18ES2VH* 1U24ES2VHA / AW24ES2VH* C US Intertek For more information visit us: www.haierductless.com www.haierductlesshelp.com

More information

ASPT Series. Multi-Position, Internal TXV. Air Handler 1½ to 5 Tons

ASPT Series. Multi-Position, Internal TXV. Air Handler 1½ to 5 Tons Series Multi-Position, Internal TXV Multi-Speed ECM Based Air Handler ½ to Tons Contents Air Handler Nomenclature... Heater Kit Nomenclature... Product Specifications... Dimensions... Airflow Data... Heat

More information

SECTION 1 - WHAT IS A BTU METER? BTU's = Flow x ΔT Any ISTEC BTU Meter System consists of the following main components:

SECTION 1 - WHAT IS A BTU METER? BTU's = Flow x ΔT Any ISTEC BTU Meter System consists of the following main components: SECTION 1 - WHAT IS A BTU METER? ISTEC BTU Meters measure energy usage by multiplying flow rate and temperature difference. As the water (or other liquid) passes through these lines, the multi-wing turbine

More information

SUBMITTAL DATA: MXZ-5C42NA MULTI-INDOOR INVERTER HEAT PUMP SYSTEM

SUBMITTAL DATA: MXZ-5C42NA MULTI-INDOOR INVERTER HEAT PUMP SYSTEM Job Name: System Reference: SUBMITTAL DATA: MXZ-5C42NA MULTI-INDOOR INVERTER HEAT PUMP SYSTEM M-SERIES Date: GENERAL FEATURES Quiet Operation Optional base pan heater to prevent ice in drain pan Limited

More information

ENH4X. Product Specifications HORIZONTAL EVAPORATOR COILS ALL CASED N COIL MODELS WARRANTY*

ENH4X. Product Specifications HORIZONTAL EVAPORATOR COILS ALL CASED N COIL MODELS WARRANTY* ENVIRONMENTALLY SOUND REFRIGERANT ENH4X Product Specifications HORIZONTAL EVAPORATOR COILS ALL CASED N COIL MODELS 2 thru 5 Tons Available for environmentally sound R 410A systems Copper tube / aluminum

More information

SUBMITTAL DATA: MXZ-3C30NA MULTI-INDOOR INVERTER HEAT-PUMP SYSTEM

SUBMITTAL DATA: MXZ-3C30NA MULTI-INDOOR INVERTER HEAT-PUMP SYSTEM Job Name: System Reference: SUBMITTAL DATA: MXZ-3C30NA MULTI-INDOOR INVERTER HEAT-PUMP SYSTEM M-SERIES Date: GENERAL FEATURES Quiet Operation Optional base pan heater to prevent ice in drain pan Limited

More information

R- 410A R-22 Size (tons) Shipping Weight (lbs) WLAU184AA 1-1/ WLAU182AA 1-1/ WLAU244AA. Model /2

R- 410A R-22 Size (tons) Shipping Weight (lbs) WLAU184AA 1-1/ WLAU182AA 1-1/ WLAU244AA. Model /2 EVAPORATOR COILS A COIL - UNCASED R- 410A or R- 22 SYSTEMS 1 1/2 5 Tons WLAU Use of the AHRI Certified TM Mark indicates a manufacturer s participation in the program. For verification of certification

More information

Karad-Dhebewadi Road Karad INDIA

Karad-Dhebewadi Road Karad INDIA MRR MDL K372LG-BXXX BLL MRL B230, B231, B130 Karad-Dhebewadi Road Karad - 415 110 D ote ales compressor drawing number and compressor model name are the same. 25-1206- 1 0591urrent Last Model ame K372LG-BXXX

More information

McQuay. Water Source Heat Pump. VF, VG, VP Vintage E, F, G. Last Manufactured: Replacement Parts List No Revision B 02/2017

McQuay. Water Source Heat Pump. VF, VG, VP Vintage E, F, G. Last Manufactured: Replacement Parts List No Revision B 02/2017 Replacement s List No. 055206700 Revision B 02/2017 McQuay Water Source Heat Pump VF, VG, VP 240-390 Vintage E, F, G Last Manufactured: 1992 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

ASTON SERIES AIR HANDLER

ASTON SERIES AIR HANDLER ASTN SEIES AI HANDLE HYDNI AND -0A T TNS Submittal Data English Language IP/Metric Units SD00H 0/ ontractor: P..: - Tons 0Hz Model Nomenclature - - - 0 AH 0 * 00 0 Model AH Series Air Handler Unit apacity

More information

AIR COOLED CONDENSING UNIT

AIR COOLED CONDENSING UNIT NEW EVOLUTION SERIES AIR COOLED CONDENSING UNIT OUTDOOR AIR COOLED CONDENSING UNIT ORIGINAL MANUFACTURED EQUIPMENT NEW EVOLUTION 7 & 8 SERIES BA-506-5 AUS Evolution Air Cooled Condensing Unit Series Content

More information

HVAC Electrical Wiring Diagrams / Ohm s Law / Sequence of Operation RV

HVAC Electrical Wiring Diagrams / Ohm s Law / Sequence of Operation RV PLEASE DO NOT BOOKMARK ANY ANYTIMECE WEBPAGES! Our system will remember the last page you viewed when logging out and back in but please DO NOT exit out when taking a test. Your place will NOT be saved.

More information

579(XX).(X)(X)(X)(X) Modularized Roof Top Air Conditioner

579(XX).(X)(X)(X)(X) Modularized Roof Top Air Conditioner When ordering parts, always state: MODEL NO. - PRODUT NO. - QUANTITY - PART NUMBER - DESRIPTION For Electric Details also state: VOLTAGE - WATTAGE USA SERVIE OFFIE Dometic orporation 0 Industrial Parkway

More information

Emerson Climate Technologies (India) Private Limited Karad Dhebewadi Road Karad INDIA

Emerson Climate Technologies (India) Private Limited Karad Dhebewadi Road Karad INDIA merson limate echnologies (ndia) rivate Limited MRR MDL merson limate echnologies (ndia) rivate Limited Karad Dhebewadi Road Karad - 415 110 D ote: ales compressor drawing number and compressor model name

More information

Emerson Climate Technologies (India) Limited Karad Dhebewadi Road Karad INDIA

Emerson Climate Technologies (India) Limited Karad Dhebewadi Road Karad INDIA merson limate echnologies (ndia) Limited MRR MDL R53KQM-D-XXX (@ 50 Hz) BLL MRL 101, 102, 103, 201, 202, 203 ote : ales compressor drawing number and compressor model name are the same. 1 01 urrent merson

More information

VRF Technical Data Book

VRF Technical Data Book VRF Technical Data Book DVM S for Euro_ET (R4A, Hz, HP) Model : Premium (Compact / Energy Efficiency) Type Standard Type History Version Modification Date Remark Ver. 1. Release DVM S (R4A, Hz, HP) for

More information

Parts Manual R410A Models

Parts Manual R410A Models Parts Manual R410A Models PTAC - PD Series (Electronic Controls) Packaged Terminal Air Conditioners Packaged Terminal Heat Pumps PTAC PARTS E (1-2010) Table of Contents Unit Identification... 2 PTAC System

More information

Product Data. CNPHP, CNRHP Evaporator Coil N Coil --- Cased Horizontal CNPHP / CNRHP

Product Data. CNPHP, CNRHP Evaporator Coil N Coil --- Cased Horizontal CNPHP / CNRHP CNPHP, CNRHP Evaporator Coil N Coil --- Cased Horizontal Product Data 06005 This horizontal design N -coil is an evaporator coil designed to provide the highest standards of reliability and durability.

More information

C7400A and C7400C Enthalpy Sensors

C7400A and C7400C Enthalpy Sensors 70 and 70 Enthalpy Sensors PROUT T FETURES PPLITION The 70 Enthalpy Sensor is used with the economizer logic modules with the,,, and performance curves; the 70 sensor is used with the logic modules with

More information

Western Electric A V a c u u m T u b e

Western Electric A V a c u u m T u b e 280A Western Electric 2 8 0 A V a c u u m T u b e Classification Half-wave, thermionic, mercury vapor rectifier The 280A vacuum tube is designed to supply direct current from an alternating-current supply.

More information

END4X, ENW4X, ENA4X. Product Specifications VERTICAL EVAPORATOR COILS ALL N COIL MODELS CASED N COILS UNCASED N COILS ENA4X WARRANTY*

END4X, ENW4X, ENA4X. Product Specifications VERTICAL EVAPORATOR COILS ALL N COIL MODELS CASED N COILS UNCASED N COILS ENA4X WARRANTY* ENVIRONMENTALLY SOUND REFRIGERANT VERTICAL EVAPORATOR COILS ALL N COIL MODELS 1½ thru 5 Tons Available for environmentally sound R 410A systems Copper tube / aluminum fin N coil with latest high tech fin

More information

AIR CONDITIONERS 2016 COLLECTION. Window Portable Dehumidifier Through The Wall Ductless Split Units. Online Interactive Edition v.1.

AIR CONDITIONERS 2016 COLLECTION. Window Portable Dehumidifier Through The Wall Ductless Split Units. Online Interactive Edition v.1. AIR CONDITIONERS 2016 COLLECTION Window Portable Dehumidifier Through The Wall Ductless Split Units Online Interactive Edition v.1.1 2016 COLLECTION AIR CONDITIONERS Stay comfortable in any room with an

More information

McQuay Climate Control Singer

McQuay Climate Control Singer Replacement Parts List No. 055204800 Revision B 01/2017 McQuay Climate Control Singer Vertical Water Source Heat Pump FC, FG, FW 240, 330, 400, 500 Vintages C, D Last Manufactured: 1986 To find your Daikin

More information

McQuay Climate Control. Water Source Heat Pump Horizontal. CC, CG, CW Vintage C, D. Last Manufactured: 1984

McQuay Climate Control. Water Source Heat Pump Horizontal. CC, CG, CW Vintage C, D. Last Manufactured: 1984 Replacement Parts List No. 055204000 Revision C 01/2017 McQuay Climate Control Water Source Heat Pump Horizontal CC, CG, CW 260-330 Vintage C, D Last Manufactured: 1984 To find your Daikin Applied parts

More information

HEAT CONTENT DECREASES U D R HEAT CONTENT INCREASESO. Btu/lb

HEAT CONTENT DECREASES U D R HEAT CONTENT INCREASESO. Btu/lb Pressure (psia) LINES OF CONSTANT ENTHALPY PRESSURE P R E S S U R E R I S E S P R E S S HEAT CONTENT DECREASES U R E D R HEAT CONTENT INCREASESO P S Btu/lb Heat Content Pressure (psia) SATURATION CURVE

More information

AIR COOLED CONDENSING UNIT

AIR COOLED CONDENSING UNIT EVOLUTION SERIES AIR COOLED CONDENSING UNIT OUTDOOR AIR COOLED CONDENSING UNIT ORIGINAL MANUFACTURED EQUIPMENT Evolution Series BA-503-3 AUS Evolution Air Cooled Condensing Unit Series Content Page Explanation

More information

SINGLE. Technical Data Book. Big Ceiling for Europe (R410A, 50Hz, H/P) Model : AC***JNCDEH (ODU: AC***JXAD*H)

SINGLE. Technical Data Book. Big Ceiling for Europe (R410A, 50Hz, H/P) Model : AC***JNCDEH (ODU: AC***JXAD*H) SINGLE Technical Data Book Big for Europe (R4A, Hz, H/P) Model : AC***JNCDEH (ODU: AC***JXAD*H) History Version Modification Date Remark Ver.1. Release SINGLE Big for Europe.4.3 Ver.1.1 Modification for

More information

RainMachine Mini- 8 Quick- Start Guide

RainMachine Mini- 8 Quick- Start Guide RainMachine Mini- 8 Quick- Start Guide Table of Contents Inside the Box... 3 Wiring Diagram... 4 Hardware Installation... 5 Initial Setup... 6 How it works... 13 Operation... 8 Program Properties... 10

More information

Series 3000 and XE-Series Engineering Data

Series 3000 and XE-Series Engineering Data Series 3000 and XE-Series Engineering Data A C A U S T R A L I A Series 3000 and XE-Series Engineering Data The NEW era of Series 3000 and XE-Series Cooling Towers continue to exceed the industry standard

More information

2.0 KEY EQUATIONS. Evaporator Net Refrigeration Effect. Compressor Work. Net Condenser Effect

2.0 KEY EQUATIONS. Evaporator Net Refrigeration Effect. Compressor Work. Net Condenser Effect 2.0 KEY EQUATIONS Evaporator Net Refrigeration Effect Q net refrigeration effect [] = (H 1 H 4 ) lb (Refrig Flow Rate) (60) min lb min hr H 1 = leaving evaporator enthalpy lb ; H 4 = entering evaporator

More information

Today s A/C systems include:

Today s A/C systems include: * www.sgvenergywise.org Replac ing your A/C system REQUIRES a permit from your c ity - it s important. WHY? Because A/C (air conditioning) is a SYSTEM, not just one piece of equipment. The thermostat,

More information

Double Layer Capacitors. PN: NEX_ series & NED_ series

Double Layer Capacitors. PN: NEX_ series & NED_ series Rev B - August 2010 www.niccomp.com Technical support: tpmg@niccomp.com Double Layer Capacitors PN: NEX_ series & NED_ series NEXC SMT Reflow Soldering NEXA / NEXG NEXS / NEXT Low Profile Radial LDD NEXM

More information

C7400A and C7400C Enthalpy Sensors

C7400A and C7400C Enthalpy Sensors 70 and 70 Enthalpy Sensors PROUT T FETURES Senses and combines temperature and humidity of outdoor air. Long lasting thermistor sensing element is accurate and stable over time. s enthalpy of outdoor air

More information

42C/V. Fan Coil Unit 42C/V

42C/V. Fan Coil Unit 42C/V 2/V Fan oil Unit 2/V arrier makes the world a better place to live by creating a comfortable, productive and healthy environment regardless of climate. It is our mission is to be customer s first choice

More information

Circuit Analysis and Ohm s Law

Circuit Analysis and Ohm s Law Study Unit Circuit Analysis and Ohm s Law By Robert Cecci Circuit analysis is one of the fundamental jobs of an electrician or electronics technician With the knowledge of how voltage, current, and resistance

More information

Solenoid valves Type EVUL

Solenoid valves Type EVUL Data sheet Solenoid valves EVUL EVUL solenoid valves are designed to fit into compact refrigeration systems. Available in servo operated versions they can be applied in liquid, suction, and hot gas lines.

More information

400 Volts, 50HZ 480 Volts, 60HZ 600 Volts, 60HZ TECHNICAL REFERENCE MANUAL

400 Volts, 50HZ 480 Volts, 60HZ 600 Volts, 60HZ TECHNICAL REFERENCE MANUAL 400 Volts, 50HZ 480 Volts, 60HZ 600 Volts, 60HZ TECHNICAL REFERENCE MANUAL FORM: MAP-TRM-E REL. July 2013 REV. 015 2013 MTE Corporation IMPORTANT USER INFORMATION NOTICE The MTE Corporation Matrix AP Harmonic

More information

Welcome. HVAC Change Out Regulations and Rater Verification California Track

Welcome. HVAC Change Out Regulations and Rater Verification California Track Welcome HVAC Change Out Regulations and Rater Verification -------------------------------- California Track Douglas Beaman Douglas Beaman Associates 612 13 th Street Modesto, CA 95354 (209) 524-1000 Doug@DougBeaman.com

More information

TS TT TU TV THE MOST ADVANCED COMPRESSOR TECHNOLOGY AVAILABLE PARAGON TWIN SCREW COMPRESSORS

TS TT TU TV THE MOST ADVANCED COMPRESSOR TECHNOLOGY AVAILABLE PARAGON TWIN SCREW COMPRESSORS TS TT TU TV THE MOST ADVANCED COMPRESSOR TECHNOLOGY AVAILABLE PARAGON TWIN SCREW COMPRESSORS THE MOST ADVANCED COMPRESSOR TECHNOLOGY AVAILABLE PARAGON TWIN SCREW COMPRESSORS Carlyle Compressors Every day

More information

Two-Stage, Variable-Speed Gas Furnace

Two-Stage, Variable-Speed Gas Furnace 80% AFUE GMV8 Two-Stage, Variable-Speed Gas Furnace Heating Input: 60,000 00,000 BTU/h Standard Features Aluminized steel, dual-diameter tubular heat exchanger Two-stage gas valve operates on two-stage

More information

ISEmax CAM40/CAS40. Technical Information

ISEmax CAM40/CAS40. Technical Information Technical Information Online measurement of nutrient parameters Ion-selective electrode system for the continuous measurement of ammonium and nitrate Application The ion-selective electrode system works

More information

Centrifuge 5427 R. Sample Handling Centrifuges CENTRIFUGES

Centrifuge 5427 R. Sample Handling Centrifuges CENTRIFUGES 184 Sample Handling Centrifuge 5427 R Soft touch one-finger closure for ergonomic operation Built-in condensation drain to eliminate water accumulation ECO shut-off can be programmed to engage after 1,2,4

More information

II/IV B.Tech (Regular) DEGREE EXAMINATION. (1X12 = 12 Marks) Answer ONE question from each unit.

II/IV B.Tech (Regular) DEGREE EXAMINATION. (1X12 = 12 Marks) Answer ONE question from each unit. Page 1 of 8 Hall Ticket Number: 14CH 404 II/IV B.Tech (Regular) DEGREE EXAMINATION June, 2016 Chemical Engineering Fourth Semester Engineering Thermodynamics Time: Three Hours Maximum : 60 Marks Answer

More information

UNIT 12: THE HYDROLOGIC CYCLE

UNIT 12: THE HYDROLOGIC CYCLE UNIT 12: THE HYDROLOGIC CYCLE After Unit 12 you should be able to: o Effectively use the charts Average Chemical Composition of Earth s Crust, Hydrosphere and Troposphere, Selected Properties of Earth

More information

REPAIR PARTS. GPH13 "M" Series Horizontal Package Heat Pumps GPH1324M41AA GPH1330M41AA GPH1336M41AA GPH1342M41AA GPH1348M41AA GPH1360M41AA

REPAIR PARTS. GPH13 M Series Horizontal Package Heat Pumps GPH1324M41AA GPH1330M41AA GPH1336M41AA GPH1342M41AA GPH1348M41AA GPH1360M41AA REPAIR PARTS GPH13 "M" Series Horizontal Package Heat Pumps GPH1324MAA GPH1330MAA GPH1336MAA GPH1342MAA GPH1348MAA GPH1360MAA This manual is to be used by qualified technicians only. 2009 Goodman Manufacturing

More information

SkyScan EWS-PRO - Manual -

SkyScan EWS-PRO - Manual - INTRODUCTION SkyScan EWS-PRO - Manual - EWS-Pro gives you advance weather warning technology you can use at home, indoors or out, and take wherever you go, for any kind of outdoor activity. Your EWS-Pro

More information

Fischer 1508BTH-45 5" Brass Barometer with Temperature & Humidity User Manual

Fischer 1508BTH-45 5 Brass Barometer with Temperature & Humidity User Manual Fischer 1508BTH-45 5" Brass Barometer with Temperature & Humidity User Manual Table of Contents 1. Introduction... 2 2. Care and Cleaning... 2 3. Barometer Operation... 2 3.1 How the aneroid barometer

More information

(HSI) LIMITED WARRANTY

(HSI) LIMITED WARRANTY ama The Payne PG8MAA/JAA 80% AFUE Gas Furnaces feature 4-way multipoise design and through-the-furnace downflow venting. The PG8MAA/JAA furnaces are approved f use with natural propane gas, and the PG8JAA

More information

BACK TO BASICS: PIPE INSULATION

BACK TO BASICS: PIPE INSULATION BACK TO BASICS: PIPE INSULATION INDUSTRIAL REFRIGERATION CONSORTIUM RESEARCH & TECHNOLOGY FORUM MAY 2-3, 2012 Todd Jekel, Ph.D., P.E. Assistant Director, IRC Overview 1 2 3 4 Basics of insulation & insulation

More information

nufacturing Company, L.P San Felipe, Suite

nufacturing Company, L.P San Felipe, Suite REPAIR PARTS (2,3,4) Multi Zone Heat Pump Outdoor Unit 2MXS18GVJUAA 3MXS24JVJUAA 4MXS32GVJUAA nufacturing Company, L.P. 5151 San Felipe, Suite 500 www.amana-hac.com www.amana-hac.com This manual is to

More information

Installation Operation Commissioning Maintenance

Installation Operation Commissioning Maintenance NA 09.13 H 09-2011 Microchip and LCD display electronic regulation and signaling electronic module for liquid coolers and heat pumps Installation Operation Commissioning Maintenance 1 CONTENTS 1 IMPORTANT

More information

Field Pro Operation and Installation Manual

Field Pro Operation and Installation Manual Field Pro Operation and Installation Manual Xtreme Research Corporation SkyScan Division P.O. Box 336, Port Richey, FL 34673-0336 1-800-732-0665 Table of Contents 1. Installation 3 2. Operation 5 3. Care

More information

24 volts (0.25 amps current-limited)

24 volts (0.25 amps current-limited) Question 1 Questions Suppose the lamp refuses to light up. A voltmeter registers 24 volts between test points C and D: A C E + 24 volts (0.25 amps current-limited) B D F First, list all the possible (single)

More information

ea980r Digital Anemometer User Manual

ea980r Digital Anemometer User Manual ea980r Digital Anemometer User Manual 1. Overview Thank you for purchasing the ennologic ea980r anemometer, a high quality instrument which measures 8 parameters: Wind Speed (mph, m/s, ft/min, knots, km/h)

More information

LED modules LED linear / area. Module RLE 2x6 EXC2 OTD Modules RLE excite

LED modules LED linear / area. Module RLE 2x6 EXC2 OTD Modules RLE excite Module RLE 2x6 EXC2 OTD Modules RLE excite Product description High efficiency outdoor modules Suitable for harsh and humid outdoor conditions Tested acc. to salt spray test (IEC 668-2-52) and harmful

More information

nufacturing Company, L.P San Felipe, Suite

nufacturing Company, L.P San Felipe, Suite Mini-Split Heat Pump Outdoor Unit RXS09LVJU RXS12LVJU RXS15LVJU RXS18LVJU RXS24LVJU REPAIR PARTS nufacturing Company, L.P. 5151 San Felipe, Suite 500 www.amana-hac.com www.amana-hac.com This manual is

More information

AN EXPERIMENTAL INVESTIGATION OF BOILING HEAT CONVECTION WITH RADIAL FLOW IN A FRACTURE

AN EXPERIMENTAL INVESTIGATION OF BOILING HEAT CONVECTION WITH RADIAL FLOW IN A FRACTURE PROCEEDINGS, Twenty-Fourth Workshop on Geothermal Reservoir Engineering Stanford University, Stanford, California, January 25-27, 1999 SGP-TR-162 AN EXPERIMENTAL INVESTIGATION OF BOILING HEAT CONVECTION

More information

Issued August DATA SHEET. 3VT5 MCCB up to 1600 A

Issued August DATA SHEET. 3VT5 MCCB up to 1600 A ssued August 9 DATA SHEET VT5 MCCB up to 0 A Based on Siemens Catalog V 8 Standard circuit breakers Releases Technical specifications Specifications VT5 circuit breakers Switch disconnectors Type Standards

More information

GMVM96 / GCVM96 ComfortNet -Compatible, Multi-Position, Modulating Variable-Speed Gas Furnace

GMVM96 / GCVM96 ComfortNet -Compatible, Multi-Position, Modulating Variable-Speed Gas Furnace / GVM96 omfortnet -ompatible, Multi-Position, Modulating Variable-Speed Gas Furnace Up to 96% AFUE abinet Features Multi-position installation: upflow, horizontal left or right ertified for direct vent

More information

0T 0TS S T TS T TS T TS 0T T T T T T 6T T TS 6T 6TS T TS 6T 6TS 6T 6TS 6T 6TS Frame.. 6. 6 6... 6.... B 6 6... A..... 0..0... 6.... 6.....06 6.66.. 6.0.....6 0... C 6..0 6. 6....... E.. D....... F 6............

More information

THIS MANUAL IS THE PROPERTY OF THE OWNER. PLEASE BE SURE TO LEAVE IT WITH THE OWNER WHEN YOU LEAVE THE JOB.

THIS MANUAL IS THE PROPERTY OF THE OWNER. PLEASE BE SURE TO LEAVE IT WITH THE OWNER WHEN YOU LEAVE THE JOB. -. September, 9 II DIMS gas-fired, power vented and separated combustion unit heaters for models HD/HDB, HDS/HD, PS/BS, P I. Fuel supply shall be shut-off and the electrical power disconnected before proceeding

More information

DOMESTIC HOT WATER PUMPS WITH FIXED-SPEED MOTOR, 3x400V AP-, AKP- and AEP- series, threaded G1/2 G1 ¼ LOREM IPSUM JE ZULT MAAR 60 HZ.

DOMESTIC HOT WATER PUMPS WITH FIXED-SPEED MOTOR, 3x400V AP-, AKP- and AEP- series, threaded G1/2 G1 ¼ LOREM IPSUM JE ZULT MAAR 60 HZ. LOREM IPSUM JE ZULT MAAR HZ m Head m/s m/s m/s m/s m/s Ø m Ø Ø Ø Ø l/s Flow kw Shaft power P Ø m/h Ø 9 Ø Ø kw 9 Total input power P Ø DOMESTIC HOT WATER PUMPS WITH FIXED-SPEED MOTOR, xv AP-, AKP- and AEP-

More information

ANSI/AHRI Standard 1250 (I-P) 2014 Standard for Performance Rating of Walk-in Coolers and Freezers

ANSI/AHRI Standard 1250 (I-P) 2014 Standard for Performance Rating of Walk-in Coolers and Freezers ANSI/AHRI Standard 1250 (I-P) 2014 Standard for Performance Rating of Walk-in Coolers and Freezers Approved by ANSI on May 19, 2015 - ERRATA SHEET FOR, PERFORMANCE RATING OF WALK-IN COOLERS AND FREEZERS

More information

Tempest Lighting Product Training. November 2010

Tempest Lighting Product Training. November 2010 Tempest Lighting Product Training November 2010 Tempest Whatever the Weather High-power lights/projectors and outdoor climates means trouble! Rain, Snow Sunlight, Heat and Cold Condensation especially

More information

AIR CONDITIONER (SPLIT TYPE) SERVICE MANUAL

AIR CONDITIONER (SPLIT TYPE) SERVICE MANUAL AIR CONDITIONER (SPLIT TYPE) SERVICE MANUAL FILE No. A10-023-1 REVISION 1 : Mar.2012 Re-edit version.( file volume down) Contents have NOT been changed. Model name: RAS-M10PKVP-E RAS-M13PKVP-E RAS-M16PKVP-E

More information

Accumulators Virginia KMP Suction Line Accumulators

Accumulators Virginia KMP Suction Line Accumulators Accumulators Virginia KMP Suction Line Accumulators The Virginia KMP suction line accumulator's purpose is to prevent excessive quantities of liquid refrigerant and oil from returning to the compressor.

More information

INSTRUCTION MANUAL FOR MM10 Relay

INSTRUCTION MANUAL FOR MM10 Relay INSTRUCTION MANUAL FOR MM10 Relay Motor Protection Relay Front Panel Overview V1 250614 MM10 Motor Protection Relay a I L1 b I L2 I L3 c h i d e I L1 Figure 1: Front panel overview f g I L2 a Run LED b

More information

Solenoid valve Types CSV 2 - CSV 22 (NC) and solenoid coil

Solenoid valve Types CSV 2 - CSV 22 (NC) and solenoid coil Data sheet Solenoid valve s CSV 2 - CSV 22 (NC) and solenoid coil CSV is a direct or servo-operated solenoid valve for liquid, suction, and hot gas lines with fluorinated refrigerants. CSV valves are for

More information

PRODUCT SPECIFICATIONS

PRODUCT SPECIFICATIONS GMV95/GV9 SERIES UP TO 95% FUE MULTI-POSITION, 2-STGE/VRILE-SPEE GS FURNE HETING PITY: 46,000 115,000 TUH GMV95 Models Qualify for a $200 Tax redit GV9 Models Qualify for a $50 Tax redit Standard Features

More information

REPAIR PARTS. GPH14 H-SERIES R-410A Package Heat Pumps GPH1424H41AA GPH1430H41AA GPH1436H41AA GPH1442H41AA GPH1448H41AA GPH1460H41AA

REPAIR PARTS. GPH14 H-SERIES R-410A Package Heat Pumps GPH1424H41AA GPH1430H41AA GPH1436H41AA GPH1442H41AA GPH1448H41AA GPH1460H41AA REPAIR PARTS GPH14 H-SERIES R-0A Package Heat Pumps GPH1424HAA GPH1430HAA GPH1436HAA GPH1442HAA GPH1448HAA GPH1460HAA This manual is to be used by qualified technicians only. 2009 Goodman Manufacturing

More information

U.S. Atomic Clock & Weather Station. Instruction Manual

U.S. Atomic Clock & Weather Station. Instruction Manual U.S. Atomic Clock & Weather Station Instruction Manual Table of Contents What is Atomic Radio Control?... 2 Parts Diagram... 3 Batteries... 4 Setting the Atomic Time and Date... 4 Setting the Clock...

More information

BV SERIES. VERTICAL BLOWER COIL UNITS Nominal Sizes 2 thru 10 Ton

BV SERIES. VERTICAL BLOWER COIL UNITS Nominal Sizes 2 thru 10 Ton BV SERIES VERTICAL BLOWER COIL UNITS Nominal Sizes 2 thru 10 Ton MAGIC AIRE BV SERIES FAN COILS ARE ETL LISTED TO U.S. AND CANADIAN SAFETY STANDARDS AND ARE ASSEMBLED TO ORDER FOR COMPETITIVE DELIVERY.

More information

Fischer Banjo Weather Station with Thermometer, Hygrometer, Barometer User Manual

Fischer Banjo Weather Station with Thermometer, Hygrometer, Barometer User Manual Fischer 4673-22 Banjo Weather Station with Thermometer, Hygrometer, Barometer User Manual Table of Contents 1. Introduction... 2 2. Care and Cleaning... 2 3. Barometer Operation... 2 3.1 How the aneroid

More information

Model: WT-3181PL Instruction Manual DC: Indoor/Outdoor Atomic Wall Clock. Get Started

Model: WT-3181PL Instruction Manual DC: Indoor/Outdoor Atomic Wall Clock. Get Started Model: WT-3181PL Instruction Manual DC: 041614 18 Indoor/Outdoor Atomic Wall Clock Round Battery Cover Get Started Step 1: Remove the round battery cover from the back of the clock. Step 2: Insert 1 fresh

More information

Method of Measuring Machinery Sound Within an Equipment Space

Method of Measuring Machinery Sound Within an Equipment Space ANSI/AHRI Standard 575 (Formerly ARI Standard 575) 2008 Standard for Method of Measuring Machinery Sound Within an Equipment Space Price $15.00 (M) $30.00 (NM) Printed in U.S.A. 8Copyright 1994, by Air-Conditioning

More information

ABB SpA COMEM Operating Unit Strada Regionale 11, Signolo Montebello Vicentino (VI) - ITALY

ABB SpA COMEM Operating Unit Strada Regionale 11, Signolo Montebello Vicentino (VI) - ITALY ABB SpA COMEM Operating Unit Strada Regionale 11, Signolo 22 36054 Montebello Vicentino (VI) - ITALY www.abb.com/transformercomponents The information contained in this document is for general information

More information

ERSATZTEILE RAS-8-12FSXN1E

ERSATZTEILE RAS-8-12FSXN1E Voltage 00V/0Hz Replacement Part Q'ty Per Unit 7E1110 7E1111 7E11 No. Part Name raw. No. Order No. Remarks 8FSXN1E 10FSXN1E FSXN1E 1 Side over L 17B A P 1 1 1 2 Side over R 17B A P27 1 1 1 Side over L2

More information

RECORD AND ANALYSE THE PRESSURE-ENTHALPY DIAGRAM FOR A COMPRESSION HEAT PUMP

RECORD AND ANALYSE THE PRESSURE-ENTHALPY DIAGRAM FOR A COMPRESSION HEAT PUMP Thermodynamics Heat cycles Heat Pump RECORD AND ANALYSE THE PRESSURE-ENTHALPY DIAGRAM FOR A COMPRESSION HEAT PUMP Demonstrate how an electric compression heat pump works Quantitatively investigate of the

More information

Innovative Sustainable Technology

Innovative Sustainable Technology Innovative Sustainable Technology DIG is committed to practices that contribute to irrigation and energy efficiency, creating healthy living conditions while maintaining environmentally sound operating

More information

Fischer Instruments Chrome and Black Wood Base Weather Station with Barometer, Hygrometer, Thermometer and Quartz Clock User Manual

Fischer Instruments Chrome and Black Wood Base Weather Station with Barometer, Hygrometer, Thermometer and Quartz Clock User Manual Fischer Instruments 1535-06 Chrome and Black Wood Base Weather Station with Barometer, Hygrometer, Thermometer and Quartz Clock User Manual Table of Contents 1. Introduction... 2 2. Care and Cleaning...

More information

CALEFFI. Modulating digital controller for heating and cooling. 161 series 01122/08 GB. replaces dp 01122/05

CALEFFI. Modulating digital controller for heating and cooling. 161 series 01122/08 GB. replaces dp 01122/05 Modulating digital controller for heating and cooling series REGI ERED SI EN ISO 00:000 Cert. n FM UNI EN ISO 00:000 Cert. n 000 0/0 G replaces dp 0/0 Function The controller can be used with three-point

More information

Flexitest Switch Assemblies Type FT-19R and FT-19RX Supersedes DB March 2008

Flexitest Switch Assemblies Type FT-19R and FT-19RX Supersedes DB March 2008 Flexitest Switch Assemblies Type FT-19R and FT-19RX Supersedes DB41-078 March 2008 FT-19R and FT-19RX FT-19R 3RU with Individual Clear Covers APPLICATION FEATURES The type FT-19R (standard length) and

More information

PART TOP VIEW. Maxim Integrated Products 1

PART TOP VIEW. Maxim Integrated Products 1 9-96; Rev ; 2/ 45, SPDT Analog Switch in SOT23-8 General Description The is a dual-supply, single-pole/doublethrow (SPDT) analog switch. On-resistance is 45 max and flat (7 max) over the specified signal

More information

Request Ensure that this Instruction Manual is delivered to the end users and the maintenance manager.

Request Ensure that this Instruction Manual is delivered to the end users and the maintenance manager. Request Ensure that this Instruction Manual is delivered to the end users and the maintenance manager. 1 -C - Safety section - This Safety section should be read before starting any work on the relay.

More information

Hadrons Desktop U.S. Atomic Clock & Weather Station

Hadrons Desktop U.S. Atomic Clock & Weather Station Hadrons Desktop U.S. Atomic Clock & Weather Station SN004 Instructions Read and save these instructions. Dear Sharper Image Customer, Thank you for your purchase of a Sharper Image product. We appreciate

More information