Y1SA Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS
|
|
- Dwight Wilkinson
- 6 years ago
- Views:
Transcription
1 TEHNIAL SPEIFIATIONS Y1SA Series EarthDirEX Geothermal Direct Geoexchange Heat Pump ooling capacity,000 to 0,000 Heating capacity 1,000 to,000 EER 19.0 to.0 and OP.8 to.0 The Y1SA Geothermal heat pump, Earth loops and air handler are an incredibly quiet and efficient way to heat and cool your home or business. ecause we are using the natural energy from the Earth, you can reduce your electric/utility bill by as much as 0%. FEATURES and ENEFITS Single Stage - opeland Scroll compressor Electronic Expansion Valve one valve for precise refrigerant control in all modes of operation Interface ontrol oard Two digit LED provides system operation, status and diagnostic information. Diagnostic: 1 event/fault codes provide troubleshooting information System Protection: Internal controls monitor system operation to protect the compressor. Three Minute Restart Time Delay: When the unit shuts down, a delay keeps the unit from restarting, eliminating the highest cause for compressor failure. Micro-hannel Indoor coil is all aluminum designed to optimize heat transfer, minimize size and cost, and increase durability and reliability. Earth Loop Seal Valve on & ton captures refrigerant in the outdoor Earth loop during off mode, complies with ASHRAE Standard 1 Oil Separator - 99% efficient and has an internal filter, installed at the factory. A second filter (shipped with the unit) is to be used as a replacement in to 8 hours Hot Gas ypass Injected into evaporator to prevent freeze up Accumulator Protection from liquid flood back and future compressor failures. Sight Glass- Included for simple indication of proper refrigerant change. Sound lanket Is standard equipment Energy Efficient rushless D lower Motor - EM constant torque in all models Improve aesthetics of your home - No exposed or noisy outdoor equipment Simpler System - Our EarthDirEX geothermal systems do not use a water to refrigerant heat exchanger, or a pump to circulate the water
2 DIMENSIONS.1. Line Voltage onnections Low Voltage onnections Liquid Line to Air Handler Vapor Line to Air Handler.0 Vapor Line to Earth Loop Liquid Line to Earth Loop OMPONENTS ontrol oard LED Diagnostic Low Voltage Terminal Strip ontactor Accumulator Electric ox over Oil Separator Relay Small Valve Large Valve Small Valve heck Valve Solenoid Valve & oil EXV Valve & oil ompressor Hot Gas Valve & oil Reversing Valve
3 FIGURES & TALES / / / 1 11/8 K.O. (typ.) A 1 /8" K.O. /8 /8 1 /8 /8 11/ 1/8 1/8 11/8 K.O. (typ.) 1/ K.O. (typ.) 11/ 1/ 1 /8 1 1/8 /8" K.O. DETAIL D H 1/ 1/ SUTION LIQUID 1 1/ 1 W " AINET SIZE H W A DETAIL D Tall 9-/ /1 18-1/ No -1/1 -/1 1 Yes
4 AINET SIZE SWITH SETTINGS OOLING OR HEATING AIRFLOW (FM & L/s) 0 = OFF, 1 = ON DRY OIL ESP (INHES) DRY OIL ESP (M) 1/ / / / NOTE: When matched with two-stage outdoor units, the airflow on low (Y1 or W1) input will be 0% of the values shown in this table. Table 1. Airflow Data for EM Air Handlers (E,V)M MINIMUM AMPAITY & MAXIMUM OVERURRENT PROTETION 0 VA, 0 & 0 HZ, SINGLE PHASE 08 VA, 0 & 0 HZ, SINGLE PHASE MA MOP MA MOP AINET APAITY HEAT KIT MODEL NUMER HHK- A SINGLE A SINGLE A SINGLE A SINGLE 0 NONE H-XX H-XX H-XX H-XX H-XX Q-XX Q-XX NONE H-XX H-XX H-XX H-XX H-XX H-XX H-XX Q-XX Q-XX Table. (E,V)M Minimum ircuit Ampacity & Maximum Overcurrent Protection
5 ELETRIAL AND PHYSIAL DATA Physical Data ompressor Data GEOTHERMAL SYSTEM Y1SA-EK ( TON) Y1SA-EK ( TON) Y1SA-E8K ( TON) Y1SA-E0K ( TON) Length (L) Width (W).... Height (H) Weight Volts-ycles-Phase (1) 08/0V, 1phase, 0Hz Min. ircuit Ampacity (MA) Max. Overcurrent Protection (MOP) 0 Rated Load Amps (RLA) Locked Rotor Amps (LRA) Air Handler Match EMMNK- EMMNK- EMMN0K- EMMN0K- Filter Size (Field Supplied) 18 x 0 x 1 18 x 0 x 1 0 x 0 x 1 0 x 0 x 1 Refrigerant Vapor Line O.D. (oth to air handler and earth loop) Liquid Line O.D. (oth to air handler and earth loop) / / /8 /8 1/ 1/ 1/ 1/ Unit is shipped from factory with nitrogen holding charge. REOMMENDED INITIAL R10-A HARGES WELL LENGTH (FT.) TON TON TON TON R-10A HARGE OZ. (LS) WELL LENGTH (FT.) R-10A HARGE OZ. (LS) WELL LENGTH (FT.) R-10A HARGE OZ. (LS) WELL LENGTH (FT.) R-10A HARGE OZ. (LS) 00 9 (9.) 8 (.) 00 1,1 (8) 00 1,1 (8) 1 9 (.) 0 9 (.) 1,1 (0.8) 1,1 (0.8) (19.9) 00 8 (. 80 1,0 () (x) 0* 1, (9) NOTES: The charge amounts shown above are for total system initial charge. * When -0 ft Earth Loops are used, refrigerant distributors are required, one for vapor and one for liquid line. (See Earth Loops next page). MODEL IDENTIFIATION ODES EX: Y1SA Y 1 S A - E K Y = Geothermal Heat Pump Design Series S = Split A = Single Stage EXV K = 08/0-1-0 E = 0/0-1-0 Nominal apacity
6 MATH UP AND APAITIES omp. Section Air Handler ooling EER Heating OP FM Y1SA-EK EMMNK-,000 1, Y1SA-EK EMMNK-,000 1, Y1SA-E8K EMMN0K- 8,000 0, Y1SA-E0K EMMN0K- 0,000 19, EARTH LOOPS Size/Length /0 (1) (1) Use part #100 distributor for vapor lines / - / to /8, part #100 distributor for vapor lines / - / to /, and part #100 for liquid line 1/. DIRET GEOEXHANGE EARTH LOOPS SKU Length Vapor Liquid 9 10 ft / / ft / / ft / / ft / / ft /8 /8 9 ft /8 / ft /8 /8 Earth Loop Design Length The sub-surface refrigerant lines used for geothermal heat exchange purposes must be sized to accommodate the maximum of the greater of the heating or cooling capacity design loads. Typically, in mostly non-porous rock or in permanently water saturated soil, an earth loop length between ft and 100 feet per ton (.-10.8m/kW) of capacity is required. Within the United States, see Figure 1 (page ) to help determine the appropriate earth loop length. For installations outside of the United States, the following rules will dictate the sizing of the earth loop. These rules assume that the earth loop will be installed within bedrock or permanently water saturated ground. For the building to be conditioned, calculate the annual heating and the annual cooling loads. Use AA Manual J or other locally recognized load calculation program. Annual ooling Load Annual Heating Load Earth Loop Needed (per Ton of System Size) Line Set Sizing between the ompressor Unit & Air Handler 1 ft 1 but ft > ft OMPRESSOR SIZE (TU)* Annual ooling Load Annual Heating Load LIQUID LINE Size of Unit (in tons) Annual ooling Load Annual Heating Load VAPOR LINE,000 -,000 1/ inch O.D. / inch O.D. 8,000-0,000 1/ inch O.D. /8 inch O.D. *ompressor size is the actual compressor size in the compressor unit box, not maximum system capacity, system size, or air handler size. Earth Loop Needed (per Ton of System Size, rounded up) Example 1,000,000 tons.8 ( ton x ft = 19 ft) 00 ft Example 8,000,000 tons 1.9 ( ton x 100 ft = 00 ft) 00 ft
7 Marine () Dry () Moist (A) Warm-Humid elow White Line NOTE: Zone includes all of Alaska except for the following burroughs in Zone 8: ethel, Northwest Arctic, Dellingham, Southeast Fairbanks, N. Star, Wade Hampton, Nome, Yukon-Koyukuk, North Slope. IE ZONES EARTH LOOP SIZE (FT/TON) 1,, A, 100, A, 80,,,, 8 1 NOTE: Zone 1 includes Hawaii, Guam, Puerto Rico, and the Virgin Islands There are exceptions to the earth loop sizes shown in this table. Within a climate zone, the weather, and underground conditions vary from place to place. The earth loop length may need to be adjusted accordingly. Earth loop size indicated in the table assumes installation within bedrock or permanently water saturated ground.
8 GENERAL TERMS OF LIMITED WARRANTY Nortek Global HVA, LL will furnish a replacement for any part of this product which fails in normal use and service within the terms and conditions of the warranty. For complete details of the Limited Warranty, including applicable terms and conditions, see your local installer or contact the Nortek Global HVA, LL warranty department for a copy. efore purchasing this appliance, read important energy cost and efficiency information available from your retailer. Specifications and illustrations subject to change without notice and without incurring obligations. Printed in U.S.A (0/01) 00E-01 (Replaces 00E-101)
ENVIRONMENTALLY SOUND R 410A REFRIGERANT
ENVIRONMENTALLY SOUND REFRIGERANT N4H3 Performance Series Product Specifications EFFICIENT 13 SEER HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase,
More informationB6VMAX Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS
TECHNICAL SPECIFICATIONS B6VMAX Series Air Handler with TXV 13-19 SEER Residential System 18,000-60,000 Btuh (Heat Pump & Air Conditioner) R-410A Refrigerant The B6VMAX Series of air handlers, when combined
More informationGB5BM Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Air Handler WARRANTY
TECHNICAL SPECIFICATIONS GB5BM Series Air Handler 13 SEER Residential System 18,000-60,000 Btuh (Heat Pump & Air Conditioner) The GB5BM Series of air handlers, when combined with our heat pump or air conditioner,
More informationEFFICIENT 13 SEER HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz
ENVIRONMENTALLY SOUND REFRIGERANT N4H3 Performance Series Product Specifications EFFICIENT 13 SEER HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase,
More informationASPT Series. Multi-Position, Internal TXV. Air Handler 1½ to 5 Tons
Series Multi-Position, Internal TXV Product Features Internal factory-installed thermal expansion valves for cooling and heat pump applications Direct drive, multi-speed ECM blower motor All-aluminum evaporator
More information4HP13 PRODUCT SPECIFICATIONS 13 SEER SPLIT SYSTEM HEAT PUMP WARRANTY
4HP13 PRODUCT SPECIFICATIONS 13 S SPLIT SYSTEM HEAT PUMP FORM NO. 4HP13-100 (07/2014) R410A Refrigerant High-quality condenser coil with copper tubing and enhanced louvered fin for maximum heat transfer
More informationDuctless Split Systems Floating Air
Ductless Split Systems Floating Air PURCHASER P.O. # DATE PROJECT LOCATION ENGINEER ARCHITECT SUBMITTED BY FOR APPROVAL FOR REFERENCE ITEM PLAN DESIGNATION QUANTITY COOLING BTU/H VOLTAGE FRIEDRICH MODEL
More informationGMVC8. ComfortNet -Compatible. Heating Input: 70, ,000 BTU/h. Two-Stage, Variable-Speed Gas Furnace
80% AFUE Heating Input: 70,000 115,000 BTU/h ComfortNet -Compatible Two-Stage, Variable-Speed Gas Furnace Standard Features Aluminized steel, dual-diameter tubular heat exchanger Two-stage gas valve operates
More informationTHE ENERGY 68,SAVING TDVI. exible Combine Modular 24, 26, 28, 30, 32, 34, 36, 38, 40, 42, 44 HP 60, 62, 64, 66 HP
I N V E RT E R ion Range exible Combine Modular TDV I TDV I TDV I INVERTER INVERTER INVERTER 14, 16, 18, 20, 22 HP TDV I 24, 26, 28, 30, 32, 34, 36, 38, 40, 42, 44 HP INVERTER INVERTER INVERTER TDV I INVERTER
More information3 Port, 2-Ton Outdoor Heat Pump
Job Name: Tag# Submittal Data Sheet 3 Port, 2-Ton Outdoor Heat Pump 3MXS24NMVJU Efficiency SEER EER HSPF Non-Ducted 17.9 12.7 12.5 Ducted 14 9.7 8.2 Mixed 15.95 11.2 10.35 Performance Cooling (Btu/hr)
More informationClimateMaster s Tranquility 22. Raj Hiremath Director of Residential Marketing
ClimateMaster s Tranquility 22 Raj Hiremath Director of Residential Marketing 1 CLIMATEMASTER Industry leader since 1950 s First to introduce 2-stage 27 EER unit First to introduce Outdoor split system
More informationProduct Data. CAPVU Evaporator Coil A Coil --- Uncased Upflow, Downflow CAPVU
CAPVU Evaporator Coil A Coil --- Uncased Upflow, Downflow Product Data CAPVU A06002 The CAPVU evaporator coils incorporate proven standards for reliable system operation and performance throughout the
More informationDCG Commercial. 7½ - 12½ Ton Packaged Gas/ Electric Up to 11.3 EER / 80% AFUE
DG ommercial ½ - ½ Ton Packaged Gas/ Electric Up to. EER / 0% AUE ooling apacity:,000,000 BTU/h Heating apacity (Output):,000 BTU/h ontents Nomenclature... Product Specifications... Expanded ooling Data...
More informationProduct Data CNPVP, CNPVT, CNPVU, CNRVU EVAPORATOR COIL N COIL - CASED AND UNCASED UPFLOW, DOWNFLOW
CNPVP, CNPVT, CNPVU, CNRVU EVPORTOR COIL N COIL - CSED ND UNCSED UPFLOW, DOWNFLOW Product Data CNPVP CNPVT (Transition) CN(P,R)VU 06008 06007 06004 This vertical design N -coil is a furnace coil designed
More informationProduct Data. CNPVP, CNRVP, CNPVT, CNRVT, CNPVU, CNRVU Evaporator Coil N Coil Cased and Uncased Upflow, Downflow
CNPVP, CNRVP, CNPVT, CNRVT, CNPVU, CNRVU Evaporator Coil N Coil Cased and Uncased Upflow, Downflow Product Data CN(P,R)VP CN(P,R)VT (Transition) A06008 A06007 This vertical design N -coil is a furnace
More informationSubmittals. Advanced Series 1U09ES2VHA / AW09ES2VH* 1U12ES2VHA / AW12ES2VH* 1U18ES2VHA / AW18ES2VH* 1U24ES2VHA / AW24ES2VH* Rev.
Submittals Advanced Series 1U09ES2VHA / AW09ES2VH* 1U12ES2VHA / AW12ES2VH* 1U18ES2VHA / AW18ES2VH* 1U24ES2VHA / AW24ES2VH* C US Intertek For more information visit us: www.haierductless.com www.haierductlesshelp.com
More informationASPT Series. Multi-Position, Internal TXV. Air Handler 1½ to 5 Tons
Series Multi-Position, Internal TXV Multi-Speed ECM Based Air Handler ½ to Tons Contents Air Handler Nomenclature... Heater Kit Nomenclature... Product Specifications... Dimensions... Airflow Data... Heat
More informationSECTION 1 - WHAT IS A BTU METER? BTU's = Flow x ΔT Any ISTEC BTU Meter System consists of the following main components:
SECTION 1 - WHAT IS A BTU METER? ISTEC BTU Meters measure energy usage by multiplying flow rate and temperature difference. As the water (or other liquid) passes through these lines, the multi-wing turbine
More informationSUBMITTAL DATA: MXZ-5C42NA MULTI-INDOOR INVERTER HEAT PUMP SYSTEM
Job Name: System Reference: SUBMITTAL DATA: MXZ-5C42NA MULTI-INDOOR INVERTER HEAT PUMP SYSTEM M-SERIES Date: GENERAL FEATURES Quiet Operation Optional base pan heater to prevent ice in drain pan Limited
More informationENH4X. Product Specifications HORIZONTAL EVAPORATOR COILS ALL CASED N COIL MODELS WARRANTY*
ENVIRONMENTALLY SOUND REFRIGERANT ENH4X Product Specifications HORIZONTAL EVAPORATOR COILS ALL CASED N COIL MODELS 2 thru 5 Tons Available for environmentally sound R 410A systems Copper tube / aluminum
More informationSUBMITTAL DATA: MXZ-3C30NA MULTI-INDOOR INVERTER HEAT-PUMP SYSTEM
Job Name: System Reference: SUBMITTAL DATA: MXZ-3C30NA MULTI-INDOOR INVERTER HEAT-PUMP SYSTEM M-SERIES Date: GENERAL FEATURES Quiet Operation Optional base pan heater to prevent ice in drain pan Limited
More informationR- 410A R-22 Size (tons) Shipping Weight (lbs) WLAU184AA 1-1/ WLAU182AA 1-1/ WLAU244AA. Model /2
EVAPORATOR COILS A COIL - UNCASED R- 410A or R- 22 SYSTEMS 1 1/2 5 Tons WLAU Use of the AHRI Certified TM Mark indicates a manufacturer s participation in the program. For verification of certification
More informationKarad-Dhebewadi Road Karad INDIA
MRR MDL K372LG-BXXX BLL MRL B230, B231, B130 Karad-Dhebewadi Road Karad - 415 110 D ote ales compressor drawing number and compressor model name are the same. 25-1206- 1 0591urrent Last Model ame K372LG-BXXX
More informationMcQuay. Water Source Heat Pump. VF, VG, VP Vintage E, F, G. Last Manufactured: Replacement Parts List No Revision B 02/2017
Replacement s List No. 055206700 Revision B 02/2017 McQuay Water Source Heat Pump VF, VG, VP 240-390 Vintage E, F, G Last Manufactured: 1992 To find your Daikin Applied parts distributor, call 1-800-377-2787
More informationASTON SERIES AIR HANDLER
ASTN SEIES AI HANDLE HYDNI AND -0A T TNS Submittal Data English Language IP/Metric Units SD00H 0/ ontractor: P..: - Tons 0Hz Model Nomenclature - - - 0 AH 0 * 00 0 Model AH Series Air Handler Unit apacity
More informationAIR COOLED CONDENSING UNIT
NEW EVOLUTION SERIES AIR COOLED CONDENSING UNIT OUTDOOR AIR COOLED CONDENSING UNIT ORIGINAL MANUFACTURED EQUIPMENT NEW EVOLUTION 7 & 8 SERIES BA-506-5 AUS Evolution Air Cooled Condensing Unit Series Content
More informationHVAC Electrical Wiring Diagrams / Ohm s Law / Sequence of Operation RV
PLEASE DO NOT BOOKMARK ANY ANYTIMECE WEBPAGES! Our system will remember the last page you viewed when logging out and back in but please DO NOT exit out when taking a test. Your place will NOT be saved.
More information579(XX).(X)(X)(X)(X) Modularized Roof Top Air Conditioner
When ordering parts, always state: MODEL NO. - PRODUT NO. - QUANTITY - PART NUMBER - DESRIPTION For Electric Details also state: VOLTAGE - WATTAGE USA SERVIE OFFIE Dometic orporation 0 Industrial Parkway
More informationEmerson Climate Technologies (India) Private Limited Karad Dhebewadi Road Karad INDIA
merson limate echnologies (ndia) rivate Limited MRR MDL merson limate echnologies (ndia) rivate Limited Karad Dhebewadi Road Karad - 415 110 D ote: ales compressor drawing number and compressor model name
More informationEmerson Climate Technologies (India) Limited Karad Dhebewadi Road Karad INDIA
merson limate echnologies (ndia) Limited MRR MDL R53KQM-D-XXX (@ 50 Hz) BLL MRL 101, 102, 103, 201, 202, 203 ote : ales compressor drawing number and compressor model name are the same. 1 01 urrent merson
More informationVRF Technical Data Book
VRF Technical Data Book DVM S for Euro_ET (R4A, Hz, HP) Model : Premium (Compact / Energy Efficiency) Type Standard Type History Version Modification Date Remark Ver. 1. Release DVM S (R4A, Hz, HP) for
More informationParts Manual R410A Models
Parts Manual R410A Models PTAC - PD Series (Electronic Controls) Packaged Terminal Air Conditioners Packaged Terminal Heat Pumps PTAC PARTS E (1-2010) Table of Contents Unit Identification... 2 PTAC System
More informationProduct Data. CNPHP, CNRHP Evaporator Coil N Coil --- Cased Horizontal CNPHP / CNRHP
CNPHP, CNRHP Evaporator Coil N Coil --- Cased Horizontal Product Data 06005 This horizontal design N -coil is an evaporator coil designed to provide the highest standards of reliability and durability.
More informationC7400A and C7400C Enthalpy Sensors
70 and 70 Enthalpy Sensors PROUT T FETURES PPLITION The 70 Enthalpy Sensor is used with the economizer logic modules with the,,, and performance curves; the 70 sensor is used with the logic modules with
More informationWestern Electric A V a c u u m T u b e
280A Western Electric 2 8 0 A V a c u u m T u b e Classification Half-wave, thermionic, mercury vapor rectifier The 280A vacuum tube is designed to supply direct current from an alternating-current supply.
More informationEND4X, ENW4X, ENA4X. Product Specifications VERTICAL EVAPORATOR COILS ALL N COIL MODELS CASED N COILS UNCASED N COILS ENA4X WARRANTY*
ENVIRONMENTALLY SOUND REFRIGERANT VERTICAL EVAPORATOR COILS ALL N COIL MODELS 1½ thru 5 Tons Available for environmentally sound R 410A systems Copper tube / aluminum fin N coil with latest high tech fin
More informationAIR CONDITIONERS 2016 COLLECTION. Window Portable Dehumidifier Through The Wall Ductless Split Units. Online Interactive Edition v.1.
AIR CONDITIONERS 2016 COLLECTION Window Portable Dehumidifier Through The Wall Ductless Split Units Online Interactive Edition v.1.1 2016 COLLECTION AIR CONDITIONERS Stay comfortable in any room with an
More informationMcQuay Climate Control Singer
Replacement Parts List No. 055204800 Revision B 01/2017 McQuay Climate Control Singer Vertical Water Source Heat Pump FC, FG, FW 240, 330, 400, 500 Vintages C, D Last Manufactured: 1986 To find your Daikin
More informationMcQuay Climate Control. Water Source Heat Pump Horizontal. CC, CG, CW Vintage C, D. Last Manufactured: 1984
Replacement Parts List No. 055204000 Revision C 01/2017 McQuay Climate Control Water Source Heat Pump Horizontal CC, CG, CW 260-330 Vintage C, D Last Manufactured: 1984 To find your Daikin Applied parts
More informationHEAT CONTENT DECREASES U D R HEAT CONTENT INCREASESO. Btu/lb
Pressure (psia) LINES OF CONSTANT ENTHALPY PRESSURE P R E S S U R E R I S E S P R E S S HEAT CONTENT DECREASES U R E D R HEAT CONTENT INCREASESO P S Btu/lb Heat Content Pressure (psia) SATURATION CURVE
More informationAIR COOLED CONDENSING UNIT
EVOLUTION SERIES AIR COOLED CONDENSING UNIT OUTDOOR AIR COOLED CONDENSING UNIT ORIGINAL MANUFACTURED EQUIPMENT Evolution Series BA-503-3 AUS Evolution Air Cooled Condensing Unit Series Content Page Explanation
More informationSINGLE. Technical Data Book. Big Ceiling for Europe (R410A, 50Hz, H/P) Model : AC***JNCDEH (ODU: AC***JXAD*H)
SINGLE Technical Data Book Big for Europe (R4A, Hz, H/P) Model : AC***JNCDEH (ODU: AC***JXAD*H) History Version Modification Date Remark Ver.1. Release SINGLE Big for Europe.4.3 Ver.1.1 Modification for
More informationRainMachine Mini- 8 Quick- Start Guide
RainMachine Mini- 8 Quick- Start Guide Table of Contents Inside the Box... 3 Wiring Diagram... 4 Hardware Installation... 5 Initial Setup... 6 How it works... 13 Operation... 8 Program Properties... 10
More informationSeries 3000 and XE-Series Engineering Data
Series 3000 and XE-Series Engineering Data A C A U S T R A L I A Series 3000 and XE-Series Engineering Data The NEW era of Series 3000 and XE-Series Cooling Towers continue to exceed the industry standard
More information2.0 KEY EQUATIONS. Evaporator Net Refrigeration Effect. Compressor Work. Net Condenser Effect
2.0 KEY EQUATIONS Evaporator Net Refrigeration Effect Q net refrigeration effect [] = (H 1 H 4 ) lb (Refrig Flow Rate) (60) min lb min hr H 1 = leaving evaporator enthalpy lb ; H 4 = entering evaporator
More informationToday s A/C systems include:
* www.sgvenergywise.org Replac ing your A/C system REQUIRES a permit from your c ity - it s important. WHY? Because A/C (air conditioning) is a SYSTEM, not just one piece of equipment. The thermostat,
More informationDouble Layer Capacitors. PN: NEX_ series & NED_ series
Rev B - August 2010 www.niccomp.com Technical support: tpmg@niccomp.com Double Layer Capacitors PN: NEX_ series & NED_ series NEXC SMT Reflow Soldering NEXA / NEXG NEXS / NEXT Low Profile Radial LDD NEXM
More informationC7400A and C7400C Enthalpy Sensors
70 and 70 Enthalpy Sensors PROUT T FETURES Senses and combines temperature and humidity of outdoor air. Long lasting thermistor sensing element is accurate and stable over time. s enthalpy of outdoor air
More information42C/V. Fan Coil Unit 42C/V
2/V Fan oil Unit 2/V arrier makes the world a better place to live by creating a comfortable, productive and healthy environment regardless of climate. It is our mission is to be customer s first choice
More informationCircuit Analysis and Ohm s Law
Study Unit Circuit Analysis and Ohm s Law By Robert Cecci Circuit analysis is one of the fundamental jobs of an electrician or electronics technician With the knowledge of how voltage, current, and resistance
More informationSolenoid valves Type EVUL
Data sheet Solenoid valves EVUL EVUL solenoid valves are designed to fit into compact refrigeration systems. Available in servo operated versions they can be applied in liquid, suction, and hot gas lines.
More information400 Volts, 50HZ 480 Volts, 60HZ 600 Volts, 60HZ TECHNICAL REFERENCE MANUAL
400 Volts, 50HZ 480 Volts, 60HZ 600 Volts, 60HZ TECHNICAL REFERENCE MANUAL FORM: MAP-TRM-E REL. July 2013 REV. 015 2013 MTE Corporation IMPORTANT USER INFORMATION NOTICE The MTE Corporation Matrix AP Harmonic
More informationWelcome. HVAC Change Out Regulations and Rater Verification California Track
Welcome HVAC Change Out Regulations and Rater Verification -------------------------------- California Track Douglas Beaman Douglas Beaman Associates 612 13 th Street Modesto, CA 95354 (209) 524-1000 Doug@DougBeaman.com
More informationTS TT TU TV THE MOST ADVANCED COMPRESSOR TECHNOLOGY AVAILABLE PARAGON TWIN SCREW COMPRESSORS
TS TT TU TV THE MOST ADVANCED COMPRESSOR TECHNOLOGY AVAILABLE PARAGON TWIN SCREW COMPRESSORS THE MOST ADVANCED COMPRESSOR TECHNOLOGY AVAILABLE PARAGON TWIN SCREW COMPRESSORS Carlyle Compressors Every day
More informationTwo-Stage, Variable-Speed Gas Furnace
80% AFUE GMV8 Two-Stage, Variable-Speed Gas Furnace Heating Input: 60,000 00,000 BTU/h Standard Features Aluminized steel, dual-diameter tubular heat exchanger Two-stage gas valve operates on two-stage
More informationISEmax CAM40/CAS40. Technical Information
Technical Information Online measurement of nutrient parameters Ion-selective electrode system for the continuous measurement of ammonium and nitrate Application The ion-selective electrode system works
More informationCentrifuge 5427 R. Sample Handling Centrifuges CENTRIFUGES
184 Sample Handling Centrifuge 5427 R Soft touch one-finger closure for ergonomic operation Built-in condensation drain to eliminate water accumulation ECO shut-off can be programmed to engage after 1,2,4
More informationII/IV B.Tech (Regular) DEGREE EXAMINATION. (1X12 = 12 Marks) Answer ONE question from each unit.
Page 1 of 8 Hall Ticket Number: 14CH 404 II/IV B.Tech (Regular) DEGREE EXAMINATION June, 2016 Chemical Engineering Fourth Semester Engineering Thermodynamics Time: Three Hours Maximum : 60 Marks Answer
More informationUNIT 12: THE HYDROLOGIC CYCLE
UNIT 12: THE HYDROLOGIC CYCLE After Unit 12 you should be able to: o Effectively use the charts Average Chemical Composition of Earth s Crust, Hydrosphere and Troposphere, Selected Properties of Earth
More informationREPAIR PARTS. GPH13 "M" Series Horizontal Package Heat Pumps GPH1324M41AA GPH1330M41AA GPH1336M41AA GPH1342M41AA GPH1348M41AA GPH1360M41AA
REPAIR PARTS GPH13 "M" Series Horizontal Package Heat Pumps GPH1324MAA GPH1330MAA GPH1336MAA GPH1342MAA GPH1348MAA GPH1360MAA This manual is to be used by qualified technicians only. 2009 Goodman Manufacturing
More informationSkyScan EWS-PRO - Manual -
INTRODUCTION SkyScan EWS-PRO - Manual - EWS-Pro gives you advance weather warning technology you can use at home, indoors or out, and take wherever you go, for any kind of outdoor activity. Your EWS-Pro
More informationFischer 1508BTH-45 5" Brass Barometer with Temperature & Humidity User Manual
Fischer 1508BTH-45 5" Brass Barometer with Temperature & Humidity User Manual Table of Contents 1. Introduction... 2 2. Care and Cleaning... 2 3. Barometer Operation... 2 3.1 How the aneroid barometer
More information(HSI) LIMITED WARRANTY
ama The Payne PG8MAA/JAA 80% AFUE Gas Furnaces feature 4-way multipoise design and through-the-furnace downflow venting. The PG8MAA/JAA furnaces are approved f use with natural propane gas, and the PG8JAA
More informationBACK TO BASICS: PIPE INSULATION
BACK TO BASICS: PIPE INSULATION INDUSTRIAL REFRIGERATION CONSORTIUM RESEARCH & TECHNOLOGY FORUM MAY 2-3, 2012 Todd Jekel, Ph.D., P.E. Assistant Director, IRC Overview 1 2 3 4 Basics of insulation & insulation
More informationnufacturing Company, L.P San Felipe, Suite
REPAIR PARTS (2,3,4) Multi Zone Heat Pump Outdoor Unit 2MXS18GVJUAA 3MXS24JVJUAA 4MXS32GVJUAA nufacturing Company, L.P. 5151 San Felipe, Suite 500 www.amana-hac.com www.amana-hac.com This manual is to
More informationInstallation Operation Commissioning Maintenance
NA 09.13 H 09-2011 Microchip and LCD display electronic regulation and signaling electronic module for liquid coolers and heat pumps Installation Operation Commissioning Maintenance 1 CONTENTS 1 IMPORTANT
More informationField Pro Operation and Installation Manual
Field Pro Operation and Installation Manual Xtreme Research Corporation SkyScan Division P.O. Box 336, Port Richey, FL 34673-0336 1-800-732-0665 Table of Contents 1. Installation 3 2. Operation 5 3. Care
More information24 volts (0.25 amps current-limited)
Question 1 Questions Suppose the lamp refuses to light up. A voltmeter registers 24 volts between test points C and D: A C E + 24 volts (0.25 amps current-limited) B D F First, list all the possible (single)
More informationea980r Digital Anemometer User Manual
ea980r Digital Anemometer User Manual 1. Overview Thank you for purchasing the ennologic ea980r anemometer, a high quality instrument which measures 8 parameters: Wind Speed (mph, m/s, ft/min, knots, km/h)
More informationLED modules LED linear / area. Module RLE 2x6 EXC2 OTD Modules RLE excite
Module RLE 2x6 EXC2 OTD Modules RLE excite Product description High efficiency outdoor modules Suitable for harsh and humid outdoor conditions Tested acc. to salt spray test (IEC 668-2-52) and harmful
More informationnufacturing Company, L.P San Felipe, Suite
Mini-Split Heat Pump Outdoor Unit RXS09LVJU RXS12LVJU RXS15LVJU RXS18LVJU RXS24LVJU REPAIR PARTS nufacturing Company, L.P. 5151 San Felipe, Suite 500 www.amana-hac.com www.amana-hac.com This manual is
More informationAN EXPERIMENTAL INVESTIGATION OF BOILING HEAT CONVECTION WITH RADIAL FLOW IN A FRACTURE
PROCEEDINGS, Twenty-Fourth Workshop on Geothermal Reservoir Engineering Stanford University, Stanford, California, January 25-27, 1999 SGP-TR-162 AN EXPERIMENTAL INVESTIGATION OF BOILING HEAT CONVECTION
More informationIssued August DATA SHEET. 3VT5 MCCB up to 1600 A
ssued August 9 DATA SHEET VT5 MCCB up to 0 A Based on Siemens Catalog V 8 Standard circuit breakers Releases Technical specifications Specifications VT5 circuit breakers Switch disconnectors Type Standards
More informationGMVM96 / GCVM96 ComfortNet -Compatible, Multi-Position, Modulating Variable-Speed Gas Furnace
/ GVM96 omfortnet -ompatible, Multi-Position, Modulating Variable-Speed Gas Furnace Up to 96% AFUE abinet Features Multi-position installation: upflow, horizontal left or right ertified for direct vent
More information0T 0TS S T TS T TS T TS 0T T T T T T 6T T TS 6T 6TS T TS 6T 6TS 6T 6TS 6T 6TS Frame.. 6. 6 6... 6.... B 6 6... A..... 0..0... 6.... 6.....06 6.66.. 6.0.....6 0... C 6..0 6. 6....... E.. D....... F 6............
More informationTHIS MANUAL IS THE PROPERTY OF THE OWNER. PLEASE BE SURE TO LEAVE IT WITH THE OWNER WHEN YOU LEAVE THE JOB.
-. September, 9 II DIMS gas-fired, power vented and separated combustion unit heaters for models HD/HDB, HDS/HD, PS/BS, P I. Fuel supply shall be shut-off and the electrical power disconnected before proceeding
More informationDOMESTIC HOT WATER PUMPS WITH FIXED-SPEED MOTOR, 3x400V AP-, AKP- and AEP- series, threaded G1/2 G1 ¼ LOREM IPSUM JE ZULT MAAR 60 HZ.
LOREM IPSUM JE ZULT MAAR HZ m Head m/s m/s m/s m/s m/s Ø m Ø Ø Ø Ø l/s Flow kw Shaft power P Ø m/h Ø 9 Ø Ø kw 9 Total input power P Ø DOMESTIC HOT WATER PUMPS WITH FIXED-SPEED MOTOR, xv AP-, AKP- and AEP-
More informationANSI/AHRI Standard 1250 (I-P) 2014 Standard for Performance Rating of Walk-in Coolers and Freezers
ANSI/AHRI Standard 1250 (I-P) 2014 Standard for Performance Rating of Walk-in Coolers and Freezers Approved by ANSI on May 19, 2015 - ERRATA SHEET FOR, PERFORMANCE RATING OF WALK-IN COOLERS AND FREEZERS
More informationTempest Lighting Product Training. November 2010
Tempest Lighting Product Training November 2010 Tempest Whatever the Weather High-power lights/projectors and outdoor climates means trouble! Rain, Snow Sunlight, Heat and Cold Condensation especially
More informationAIR CONDITIONER (SPLIT TYPE) SERVICE MANUAL
AIR CONDITIONER (SPLIT TYPE) SERVICE MANUAL FILE No. A10-023-1 REVISION 1 : Mar.2012 Re-edit version.( file volume down) Contents have NOT been changed. Model name: RAS-M10PKVP-E RAS-M13PKVP-E RAS-M16PKVP-E
More informationAccumulators Virginia KMP Suction Line Accumulators
Accumulators Virginia KMP Suction Line Accumulators The Virginia KMP suction line accumulator's purpose is to prevent excessive quantities of liquid refrigerant and oil from returning to the compressor.
More informationINSTRUCTION MANUAL FOR MM10 Relay
INSTRUCTION MANUAL FOR MM10 Relay Motor Protection Relay Front Panel Overview V1 250614 MM10 Motor Protection Relay a I L1 b I L2 I L3 c h i d e I L1 Figure 1: Front panel overview f g I L2 a Run LED b
More informationSolenoid valve Types CSV 2 - CSV 22 (NC) and solenoid coil
Data sheet Solenoid valve s CSV 2 - CSV 22 (NC) and solenoid coil CSV is a direct or servo-operated solenoid valve for liquid, suction, and hot gas lines with fluorinated refrigerants. CSV valves are for
More informationPRODUCT SPECIFICATIONS
GMV95/GV9 SERIES UP TO 95% FUE MULTI-POSITION, 2-STGE/VRILE-SPEE GS FURNE HETING PITY: 46,000 115,000 TUH GMV95 Models Qualify for a $200 Tax redit GV9 Models Qualify for a $50 Tax redit Standard Features
More informationREPAIR PARTS. GPH14 H-SERIES R-410A Package Heat Pumps GPH1424H41AA GPH1430H41AA GPH1436H41AA GPH1442H41AA GPH1448H41AA GPH1460H41AA
REPAIR PARTS GPH14 H-SERIES R-0A Package Heat Pumps GPH1424HAA GPH1430HAA GPH1436HAA GPH1442HAA GPH1448HAA GPH1460HAA This manual is to be used by qualified technicians only. 2009 Goodman Manufacturing
More informationU.S. Atomic Clock & Weather Station. Instruction Manual
U.S. Atomic Clock & Weather Station Instruction Manual Table of Contents What is Atomic Radio Control?... 2 Parts Diagram... 3 Batteries... 4 Setting the Atomic Time and Date... 4 Setting the Clock...
More informationBV SERIES. VERTICAL BLOWER COIL UNITS Nominal Sizes 2 thru 10 Ton
BV SERIES VERTICAL BLOWER COIL UNITS Nominal Sizes 2 thru 10 Ton MAGIC AIRE BV SERIES FAN COILS ARE ETL LISTED TO U.S. AND CANADIAN SAFETY STANDARDS AND ARE ASSEMBLED TO ORDER FOR COMPETITIVE DELIVERY.
More informationFischer Banjo Weather Station with Thermometer, Hygrometer, Barometer User Manual
Fischer 4673-22 Banjo Weather Station with Thermometer, Hygrometer, Barometer User Manual Table of Contents 1. Introduction... 2 2. Care and Cleaning... 2 3. Barometer Operation... 2 3.1 How the aneroid
More informationModel: WT-3181PL Instruction Manual DC: Indoor/Outdoor Atomic Wall Clock. Get Started
Model: WT-3181PL Instruction Manual DC: 041614 18 Indoor/Outdoor Atomic Wall Clock Round Battery Cover Get Started Step 1: Remove the round battery cover from the back of the clock. Step 2: Insert 1 fresh
More informationMethod of Measuring Machinery Sound Within an Equipment Space
ANSI/AHRI Standard 575 (Formerly ARI Standard 575) 2008 Standard for Method of Measuring Machinery Sound Within an Equipment Space Price $15.00 (M) $30.00 (NM) Printed in U.S.A. 8Copyright 1994, by Air-Conditioning
More informationABB SpA COMEM Operating Unit Strada Regionale 11, Signolo Montebello Vicentino (VI) - ITALY
ABB SpA COMEM Operating Unit Strada Regionale 11, Signolo 22 36054 Montebello Vicentino (VI) - ITALY www.abb.com/transformercomponents The information contained in this document is for general information
More informationERSATZTEILE RAS-8-12FSXN1E
Voltage 00V/0Hz Replacement Part Q'ty Per Unit 7E1110 7E1111 7E11 No. Part Name raw. No. Order No. Remarks 8FSXN1E 10FSXN1E FSXN1E 1 Side over L 17B A P 1 1 1 2 Side over R 17B A P27 1 1 1 Side over L2
More informationRECORD AND ANALYSE THE PRESSURE-ENTHALPY DIAGRAM FOR A COMPRESSION HEAT PUMP
Thermodynamics Heat cycles Heat Pump RECORD AND ANALYSE THE PRESSURE-ENTHALPY DIAGRAM FOR A COMPRESSION HEAT PUMP Demonstrate how an electric compression heat pump works Quantitatively investigate of the
More informationInnovative Sustainable Technology
Innovative Sustainable Technology DIG is committed to practices that contribute to irrigation and energy efficiency, creating healthy living conditions while maintaining environmentally sound operating
More informationFischer Instruments Chrome and Black Wood Base Weather Station with Barometer, Hygrometer, Thermometer and Quartz Clock User Manual
Fischer Instruments 1535-06 Chrome and Black Wood Base Weather Station with Barometer, Hygrometer, Thermometer and Quartz Clock User Manual Table of Contents 1. Introduction... 2 2. Care and Cleaning...
More informationCALEFFI. Modulating digital controller for heating and cooling. 161 series 01122/08 GB. replaces dp 01122/05
Modulating digital controller for heating and cooling series REGI ERED SI EN ISO 00:000 Cert. n FM UNI EN ISO 00:000 Cert. n 000 0/0 G replaces dp 0/0 Function The controller can be used with three-point
More informationFlexitest Switch Assemblies Type FT-19R and FT-19RX Supersedes DB March 2008
Flexitest Switch Assemblies Type FT-19R and FT-19RX Supersedes DB41-078 March 2008 FT-19R and FT-19RX FT-19R 3RU with Individual Clear Covers APPLICATION FEATURES The type FT-19R (standard length) and
More informationPART TOP VIEW. Maxim Integrated Products 1
9-96; Rev ; 2/ 45, SPDT Analog Switch in SOT23-8 General Description The is a dual-supply, single-pole/doublethrow (SPDT) analog switch. On-resistance is 45 max and flat (7 max) over the specified signal
More informationRequest Ensure that this Instruction Manual is delivered to the end users and the maintenance manager.
Request Ensure that this Instruction Manual is delivered to the end users and the maintenance manager. 1 -C - Safety section - This Safety section should be read before starting any work on the relay.
More informationHadrons Desktop U.S. Atomic Clock & Weather Station
Hadrons Desktop U.S. Atomic Clock & Weather Station SN004 Instructions Read and save these instructions. Dear Sharper Image Customer, Thank you for your purchase of a Sharper Image product. We appreciate
More information