42C/V. Fan Coil Unit 42C/V
|
|
- Maximilian Warren
- 5 years ago
- Views:
Transcription
1 2/V Fan oil Unit 2/V
2 arrier makes the world a better place to live by creating a comfortable, productive and healthy environment regardless of climate. It is our mission is to be customer s first choice for air conditioning, heating and refrigeration solutions everywhere around the world. Great Hall of the People, Beijing, hina Nomenclature Feature Technical Data Dimension Fan urve Electric data Kremlin, Moscow, Russia White House, Washington, USA Imperial Palace, Tokyo, Japan
3 MODEL NUMBER NOMENLATURE 2 L L UNIT ONNETION DIRETION UNIT SIZE MODEL TYPE PRODUT SERIES DIGIT NO. 1 2 PRODUT SERIES 2 : FAN OIL UNIT DIGIT NO. 3 MODEL TYPE L : Horizontal cabinet FU VL : Vertical cabinet FU VM : Vertical concealed FU VP : Vertical concealed FU (high static pressure) DIGIT NO. UNIT SIZE 002 : m 3 /h 003 : m 3 /h DIGIT NO. UNIT ONNETION DIRETION L : LEFT R : RIGHT Air Flow 0m 3 /h 01
4 arrier 2/V is a range of fan coil units designed for horizontal/vertical, concealed/cabinet application. Seven size of various type of fan coil unit Airflow from -0MH, cooling capacity from 0-0w 2-pipe application oil rows: 2 rows coil Left/Right connection Minimum dimension ompact design of 2/V with thick depth of the unit. High efficiency opper tubes are mechanically bonded into slit aluminum fin collars, which ensure the heat transferring better. Low noise levels Low noise level with optimized fan, low speed motor and special acoustic materials. High Quality arrier quality philosophy embraces the product itself, its conception, design and the integrity of its declared performance (proven in rigorous laboratory tests) as well as the manufacturing process, materials and components used to create the product. Easy Maintenance 2/V use a heavy gage, galvanized steel with closed-cell, fire-retardant foam insulation. never touched the case, so that the corrosion is minimized and a long life is ensured. All coils are factory leakage tested. The motor/fan can be easily removed from the units, which makes it easy for maintenance. 02
5 Various series of FU with excellent performance 2E: Horizontal oncealed Type (More details in 2E catalog) 2VM: Vertical oncealed Type 2VP: Vertical oncealed Type with High static pressure motor 2L: Horizontal abinet Type 2VL: Vertical abinet Type 03
6 Technical Data L/VL/VM/VP Nominal Airflow m 3 /h High Med Low ooling apacity KW Heating apacity KW Input Power W VL/VM/L VP Sound db (A) VL/VM/L VP Flow l/min. 1 2 Pressure Drop Kpa 1 3 Fan Type Qty entrifugal, Front urve 2 Motor Type Qty Permanent, apacitive oil oil onnection Type Working Pressure In-Out ondensing Drain opper tube, double slit sheet 1.MPa 3/ FPT 3/ MPT VL Net Weight kg L VM/VP Accessory VL L/VM/VP Thermostat Note: 1. ooling capacity based on: Entering water temperature, water temperature rise, Air temperature: /1., DB/WB. 2. Heating capacity based on: Entering water temperature 0, Air temperature, DB. 3. Nominal Airflow, cooling capacity, heating capacity based on: ESP=0Pa(VL/L/VM), ESP=Pa (VP). Performance data are based on high speed. 0
7 Dimension 2VL A Air Return Grilles 3/ FPT Inlet 3/ FPT Outlet Switch Terminal Block 1 2 Fixing Slots() Dimension 2VL A B Levelling Screws() Drain Tube Filter Fixing Slots(2) B 1 2 B 1 3 Dimension 2L A B / 3/ / Filter 1 2 Fixing Slots() B A / 3/ 3 2 B A D E.1 2 VM/VP A B Dimension D E Fixing Slots() L FPT Inlet FPT Outlet Terminal Block MPT Drain ONN Air Return Grilles 2VM/VP Air Vent 0 FPT Inlet FPT Outlet Fan Motor Terminal Block 0 0 Drain Tube B Levelling Screws Filter 0
8 l/min kpa.0wb 2.0DB 1.0WB 2.0DB 2.0DB 1.0WB 2.0DB.0DB ooling apacity Entering Temperature flow Pressure Drop TH SH TH SH TH SH TH SH TH SH Entering Air Temperature Note: Performance data are based on high speed. To calculate Med and Low speed data refers to the capacity multiplier vs. speed table.
9 0 l/min kpa 1.WB.0DB.0WB.0DB 2.0DB.0WB.0WB 2.0DB.0DB.0DB ooling apacity Entering Temperature flow Pressure Drop TH SH TH SH TH SH TH SH TH SH TH SH Entering Air Temperature apacity multiplier vs. speed table Med TH SH TH SH Low
10 0 l/min kpa.0wb 2.0DB 1.0WB 2.0DB 2.0DB 1.0WB 2.0DB.0DB Entering Temperature flow Pressure Drop TH SH TH SH TH SH TH SH TH SH Entering Air Temperature Note: Performance data are based on high speed. To calculate Med and Low speed data refers to the capacity multiplier vs. speed table. ooling apacity
11 0 l/min kpa 1.WB.0DB.0WB.0DB 2.0DB.0WB.0WB 2.0DB.0DB.0DB Entering Temperature flow Pressure Drop TH SH TH SH TH SH TH SH TH SH TH SH Entering Air Temperature apacity multiplier vs. speed table Med TH SH TH SH Low ooling apacity
12 l/min kpa.0wb 2.0DB 1.0WB 2.0DB 2.0DB 1.0WB 2.0DB.0DB Entering Temperature flow Pressure Drop TH SH TH SH TH SH TH SH TH SH Entering Air Temperature Note: Performance data are based on high speed. To calculate Med and Low speed data refers to the capacity multiplier vs. speed table. ooling apacity
13 l/min kpa 1.WB.0DB.0WB.0DB 2.0DB.0WB.0WB 2.0DB.0DB.0DB Entering Temperature flow Pressure Drop TH SH TH SH TH SH TH SH TH SH TH SH Entering Air Temperature apacity multiplier vs. speed table Med TH SH TH SH Low ooling apacity
14 ooling apacity 0 Entering Temperature flow l/min Pressure Drop kpa Entering Air Temperature.0WB 1.0WB 1.0WB 2.0DB 2.0DB 2.0DB 2.0DB.0DB TH SH TH SH TH SH TH SH TH SH Note: Performance data are based on high speed. To calculate Med and Low speed data refers to the capacity multiplier vs. speed table.
15 l/min kpa 1.WB.0DB.0WB.0DB 2.0DB.0WB.0WB 2.0DB.0DB.0DB apacity multiplier vs. speed table Med TH SH TH SH Low ooling apacity Entering Temperature flow Pressure Drop TH SH TH SH TH SH TH SH TH SH TH SH Entering Air Temperature
16 l/min kpa Heating apacity.0db Entering Temperature Entering Air Temperature Entering Temperature flow
17 Heating Performance correction Heating capacity is based on DB entering air temperature and high speed air flow. Example: Given: Unit size: 00 flow: 1l/min Entering water temperature: 0 Entering air temperature: 1 DB From heating capacity table, unit 00 provides 0W heating capacity when operating at 0 entering water and DB entering air temperature. The coil heating capacity per 1 temperature difference is: 0 / (0-) =2W/ Actual heating capacity at 1 DB entering air temperature is: 2 X (0-1) = 0W apacity multiplier vs. speed table
18 Fan Performance Standard Static Pressure Unit (Pa) ESP (Pa) Airflow (m 3 /min) High Static Pressure Unit ESP Airflow (m 3 /min) Based on dry air condition, high speed, without filter and grills. 1
19 Electric Data Electric Diagram O L M H Red Blue White Yellow ap apacitor FM Fan & Motor SS Switch O Off TB Terminal Block Factory Wiring Field Wiring One motor used in model 002,003,00,00,00 Two motors used in model 00,0,0 Motor input power Power (W) urrent (A) VL/L/VM VP VL/L/VM VP Motor output power Power (W) VL/L/VM VP Note: Base on high speed, 0V/1PH/0HZ. Unit onfiguration Base Unit Filter Speed Switch Thermostat 2L VM Vp VL Note: Refers to the standard accessory Refers to the options. ustomers need to order it dividually
20 T-2/V-00-01(E)
ASPT Series. Multi-Position, Internal TXV. Air Handler 1½ to 5 Tons
Series Multi-Position, Internal TXV Product Features Internal factory-installed thermal expansion valves for cooling and heat pump applications Direct drive, multi-speed ECM blower motor All-aluminum evaporator
More informationENH4X. Product Specifications HORIZONTAL EVAPORATOR COILS ALL CASED N COIL MODELS WARRANTY*
ENVIRONMENTALLY SOUND REFRIGERANT ENH4X Product Specifications HORIZONTAL EVAPORATOR COILS ALL CASED N COIL MODELS 2 thru 5 Tons Available for environmentally sound R 410A systems Copper tube / aluminum
More informationEND4X, ENW4X, ENA4X. Product Specifications VERTICAL EVAPORATOR COILS ALL N COIL MODELS CASED N COILS UNCASED N COILS ENA4X WARRANTY*
ENVIRONMENTALLY SOUND REFRIGERANT VERTICAL EVAPORATOR COILS ALL N COIL MODELS 1½ thru 5 Tons Available for environmentally sound R 410A systems Copper tube / aluminum fin N coil with latest high tech fin
More informationTHE ENERGY 68,SAVING TDVI. exible Combine Modular 24, 26, 28, 30, 32, 34, 36, 38, 40, 42, 44 HP 60, 62, 64, 66 HP
I N V E RT E R ion Range exible Combine Modular TDV I TDV I TDV I INVERTER INVERTER INVERTER 14, 16, 18, 20, 22 HP TDV I 24, 26, 28, 30, 32, 34, 36, 38, 40, 42, 44 HP INVERTER INVERTER INVERTER TDV I INVERTER
More informationProduct Data. CAPVU Evaporator Coil A Coil --- Uncased Upflow, Downflow CAPVU
CAPVU Evaporator Coil A Coil --- Uncased Upflow, Downflow Product Data CAPVU A06002 The CAPVU evaporator coils incorporate proven standards for reliable system operation and performance throughout the
More informationBV SERIES. VERTICAL BLOWER COIL UNITS Nominal Sizes 2 thru 10 Ton
BV SERIES VERTICAL BLOWER COIL UNITS Nominal Sizes 2 thru 10 Ton MAGIC AIRE BV SERIES FAN COILS ARE ETL LISTED TO U.S. AND CANADIAN SAFETY STANDARDS AND ARE ASSEMBLED TO ORDER FOR COMPETITIVE DELIVERY.
More informationProduct Data. CNPVP, CNRVP, CNPVT, CNRVT, CNPVU, CNRVU Evaporator Coil N Coil Cased and Uncased Upflow, Downflow
CNPVP, CNRVP, CNPVT, CNRVT, CNPVU, CNRVU Evaporator Coil N Coil Cased and Uncased Upflow, Downflow Product Data CN(P,R)VP CN(P,R)VT (Transition) A06008 A06007 This vertical design N -coil is a furnace
More information579(XX).(X)(X)(X)(X) Modularized Roof Top Air Conditioner
When ordering parts, always state: MODEL NO. - PRODUT NO. - QUANTITY - PART NUMBER - DESRIPTION For Electric Details also state: VOLTAGE - WATTAGE USA SERVIE OFFIE Dometic orporation 0 Industrial Parkway
More informationR- 410A R-22 Size (tons) Shipping Weight (lbs) WLAU184AA 1-1/ WLAU182AA 1-1/ WLAU244AA. Model /2
EVAPORATOR COILS A COIL - UNCASED R- 410A or R- 22 SYSTEMS 1 1/2 5 Tons WLAU Use of the AHRI Certified TM Mark indicates a manufacturer s participation in the program. For verification of certification
More informationVRF Technical Data Book
VRF Technical Data Book DVM S for Euro_ET (R4A, Hz, HP) Model : Premium (Compact / Energy Efficiency) Type Standard Type History Version Modification Date Remark Ver. 1. Release DVM S (R4A, Hz, HP) for
More informationProduct Data. CNPHP, CNRHP Evaporator Coil N Coil --- Cased Horizontal CNPHP / CNRHP
CNPHP, CNRHP Evaporator Coil N Coil --- Cased Horizontal Product Data 06005 This horizontal design N -coil is an evaporator coil designed to provide the highest standards of reliability and durability.
More informationB6VMAX Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS
TECHNICAL SPECIFICATIONS B6VMAX Series Air Handler with TXV 13-19 SEER Residential System 18,000-60,000 Btuh (Heat Pump & Air Conditioner) R-410A Refrigerant The B6VMAX Series of air handlers, when combined
More informationXHDU Cassette type fan-coils for double/four pipe connections 1,98-14 kw HYDRONIC TERMINALS
HYDRONIC TERMINALS XHDU 402 1203 Versions XHDU 2T XHDU-R 2T XHDU 4T XHDE 2T Single coil for double pipe connections Single coil for double pipe connections with heater Double coil for four pipe connections
More informationMcQuay. Water Source Heat Pump. VF, VG, VP Vintage E, F, G. Last Manufactured: Replacement Parts List No Revision B 02/2017
Replacement s List No. 055206700 Revision B 02/2017 McQuay Water Source Heat Pump VF, VG, VP 240-390 Vintage E, F, G Last Manufactured: 1992 To find your Daikin Applied parts distributor, call 1-800-377-2787
More informationAir Cooler Industry AC-LN 1-7 / ACA-LN 2-7 / ACAF-LN 2-7
ir ooler Industry -LN -7 / -LN -7 / F-LN -7 Symbol General The -LN -7 air cooler series can be used in all areas where either oil or water-glycol is to be cooled with air. The coolers with an axial fan
More informationEnergy Efficient Easy to Install Extended Service Life. Horizontal Direct Drive Blower Coils BUILD YOUR REPUTATION ON OURS
Energy Efficient Easy to Install Extended Service Life Energy efficient compact blower coils Ideal for educational, hospitality, multi-family, or other commercial environments Designed for ducted applications
More informationWISE Damper. Active damper for Swegon s WISE System for demand-controlled ventilation QUICK FACTS
Active damper for Swegon s WISE System for demand-controlled ventilation QUICK FACTS Variable or constant flow regulation or constant pressure regulation Wireless communication via radio Integrated sensor
More informationGB5BM Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Air Handler WARRANTY
TECHNICAL SPECIFICATIONS GB5BM Series Air Handler 13 SEER Residential System 18,000-60,000 Btuh (Heat Pump & Air Conditioner) The GB5BM Series of air handlers, when combined with our heat pump or air conditioner,
More informationModel 33SZ Basic Unit OPTIONAL FILTER RH COIL CONNECTION PRIMARY/ DEDICATED OUTDOOR AIR MULTI-POINT FLOW SENSOR 5 3/4" (146)
DESRIPTION: Sensible cooling coil on the induced air inlet handles zone sensible load. Opposite side to controls location. luminum ripple fins (10 PI) and 1/" (13) copper tubes. and of coil connection
More informationGMVC8. ComfortNet -Compatible. Heating Input: 70, ,000 BTU/h. Two-Stage, Variable-Speed Gas Furnace
80% AFUE Heating Input: 70,000 115,000 BTU/h ComfortNet -Compatible Two-Stage, Variable-Speed Gas Furnace Standard Features Aluminized steel, dual-diameter tubular heat exchanger Two-stage gas valve operates
More informationPRODUCT SPECIFICATIONS
GMV95/GV9 SERIES UP TO 95% FUE MULTI-POSITION, 2-STGE/VRILE-SPEE GS FURNE HETING PITY: 46,000 115,000 TUH GMV95 Models Qualify for a $200 Tax redit GV9 Models Qualify for a $50 Tax redit Standard Features
More information3 Port, 2-Ton Outdoor Heat Pump
Job Name: Tag# Submittal Data Sheet 3 Port, 2-Ton Outdoor Heat Pump 3MXS24NMVJU Efficiency SEER EER HSPF Non-Ducted 17.9 12.7 12.5 Ducted 14 9.7 8.2 Mixed 15.95 11.2 10.35 Performance Cooling (Btu/hr)
More informationSupply air beam. Contact, Overview, Index. Guideline heating and cooling. Plexus. Professor / Professor Plus. Premum / Premax / Solus.
Contact, Overview, Index Guideline heating and cooling Plexus Professor / Professor Plus Premum / Premax / Architect Polaris I & S Plafond Podium Celo Cabinett Capella Carat Fasadium Atrium / Loggia Regula
More informationASPT Series. Multi-Position, Internal TXV. Air Handler 1½ to 5 Tons
Series Multi-Position, Internal TXV Multi-Speed ECM Based Air Handler ½ to Tons Contents Air Handler Nomenclature... Heater Kit Nomenclature... Product Specifications... Dimensions... Airflow Data... Heat
More informationProduct Data CNPVP, CNPVT, CNPVU, CNRVU EVAPORATOR COIL N COIL - CASED AND UNCASED UPFLOW, DOWNFLOW
CNPVP, CNPVT, CNPVU, CNRVU EVPORTOR COIL N COIL - CSED ND UNCSED UPFLOW, DOWNFLOW Product Data CNPVP CNPVT (Transition) CN(P,R)VU 06008 06007 06004 This vertical design N -coil is a furnace coil designed
More informationPARTS CATALOG MXZ-3C54VA - E1 MXZ-3C68VA - E1 MXZ-4C71VA - E1 MXZ-4C80VA - E1 MXZ-5C100VA - E1 MXZ-6C120VA - E1 OUTDOOR UNIT. No. OBB584 HFC.
SPLIT-TYPE AIR CONDITIONERS OUTDOOR UNIT PARTS CATALO HFC utilized R0A OBB Models MXZ-CVA - E MXZ-C6VA - E MXZ-CVA - E MXZ-C0VA - E MXZ-C00VA - E MXZ-6C0VA - E CONTENTS. PARTS LIST. OPTIONAL PARTS SERVICE
More informationALC. ALBATROSS Supply air terminal for large airflows
ALBATROSS Supply air terminal for large airflows Quick facts Large airflows Suitable for cooling or heating Manual or motorised adjustment Pressure drop independent of selected spread pattern Can be used
More informationEUROVENT 8/12 SOUND TEST METHOD FOR DUCTED FAN COIL UNITS. FCP 2008 testing procedures FCP acoustical test method pag. 1
EUROVENT 8/12 SOUND TEST METHOD FOR DUCTED FAN COIL UNITS FCP 2008 testing procedures FCP acoustical test method pag. 1 CONTENTS 1 - PURPOSE... 3 2 - NORMATIVE REFERENCES... 3 3 - DEFINITIONS... 3 3.1
More informationENVIRONMENTALLY SOUND R 410A REFRIGERANT
ENVIRONMENTALLY SOUND REFRIGERANT N4H3 Performance Series Product Specifications EFFICIENT 13 SEER HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase,
More informationSINGLE. Technical Data Book. Big Ceiling for Europe (R410A, 50Hz, H/P) Model : AC***JNCDEH (ODU: AC***JXAD*H)
SINGLE Technical Data Book Big for Europe (R4A, Hz, H/P) Model : AC***JNCDEH (ODU: AC***JXAD*H) History Version Modification Date Remark Ver.1. Release SINGLE Big for Europe.4.3 Ver.1.1 Modification for
More informationCROSS FLOW COOLING TOWER
CROSS FLOW COOLING TOWER LUCKY GREEN THAI INDUSTRIES CO LTD Material Specification Model LGX 80 00 0 00 0 300 30 400 00 600 700 800 000 Motor Totally enclosed Totally enclosed fan cooled Driving System
More informationCDD/CDR. Circular ceiling diffuser for supply air QUICK FACTS
Circular ceiling diffuser for supply air QUICK FACTS Spread pattern can be shielded Used with commissioning box ALS Cleanable Adjustable slot Perforated diffuser face = CDD Non-perforated diffuser face
More informationCircular duct grille. Dimensions. Description. Maintenance The grille should be removed to gain access to the duct.
Dimensions B+0 A+0 A B Description RGS is a rectangular ventilation grille with vertical adjustable bars for direct installation in circular ducts. The grille can be used for both supply and exhaust air.
More informationKSV. Slot diffusers. Ordering code. Description. Linear diffusers 1 / 16
Linear diffusers 1 / 1 KSV Slot diffusers Ordering code Number of slots Diffuser Length (mm) KSV - 1... - 19 Description KSV is an air terminal element primarily designated for air supply. It is suitable
More informationGTH. Rectangular double deflection grille QUICK FACTS
Rectangular double deflection grille QUICK FACTS For supply air Adjustable air deflectors Cleanable Installed using mounting frames FHB / FHA or commissioning box TRG Available in alternative colours A
More informationASTON SERIES AIR HANDLER
ASTN SEIES AI HANDLE HYDNI AND -0A T TNS Submittal Data English Language IP/Metric Units SD00H 0/ ontractor: P..: - Tons 0Hz Model Nomenclature - - - 0 AH 0 * 00 0 Model AH Series Air Handler Unit apacity
More informationPARTS CATALOG. No. OBB702 REVISED EDITION-C. Models
Revision C: MXZ-3C24/3C30/4C36/5C42NA2 and MXZ-2C20/3C24/3C30NAHZ2 have been added. Please void OBB702 REVISED EDITION-B. OUTDOOR INDOOR UNIT UNIT PARTS CATALOG No. OBB702 REVISED EDITION-C Models MXZ-3C24NA
More informationInverter Multi-Split System
Inverter MultiSplit System Specifications Inverter MultiSplit Fan coil unit Fan Coil Unit Model RAVMS3KCVT RAVMS3KCVT RASMS3KCVT RAVM22S3KCVT RAVM24S3KCVT Standard Cooling Capacity (btu/hr) 9,212 12,624
More informationCircular duct grille
Dimensions B+0 A+0 A B Description is a rectangular ventilation grille with vertical adjustable bars for direct installation in circular ducts. The grille can be used for both supply and exhaust air. The
More informationEXPLODED DIAGRAM - PARTS VIEW
Power Supply Sales Model: KSIL018-H216-I 208-230V~ / 1ph / 60Hz EXPLODED DIAGRAM - PARTS VIEW This information is to be used by qualify AC technicians only KSIL1816- Drawing No. D2IL16181301 Above information
More informationVK2 volume flow controller Overview
New option with sound attenuator Maintenance-free VK2 volume flow controller that operates without an auxiliary power supply, for ventilation and air conditioning systems. Adjustable on site. Outstanding
More informationGRC. Circular egg crate grille for transfer/extract air and wall/ceiling mounting QUICK FACTS
Circular egg crate grille for transfer/extract air and wall/ceiling mounting QUICK FACTS For exhaust air 91% free area Handles large airflows Cleanable Can be used with commissioning box ALS Standard colour
More informationERSATZTEILE RAS-8-12FSXN1E
Voltage 00V/0Hz Replacement Part Q'ty Per Unit 7E1110 7E1111 7E11 No. Part Name raw. No. Order No. Remarks 8FSXN1E 10FSXN1E FSXN1E 1 Side over L 17B A P 1 1 1 2 Side over R 17B A P27 1 1 1 Side over L2
More informationEFFICIENT 13 SEER HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz
ENVIRONMENTALLY SOUND REFRIGERANT N4H3 Performance Series Product Specifications EFFICIENT 13 SEER HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase,
More informationAIR CONDITIONER (SPLIT TYPE) SERVICE MANUAL
AIR CONDITIONER (SPLIT TYPE) SERVICE MANUAL FILE No. A10-023-1 REVISION 1 : Mar.2012 Re-edit version.( file volume down) Contents have NOT been changed. Model name: RAS-M10PKVP-E RAS-M13PKVP-E RAS-M16PKVP-E
More informationAir distribution systems. Jet nozzle DW-N2... Swivel jet nozzle DW-V2... Twist nozzle DW-V2-...-DR
Air distribution systems Jet nozzle DW-N... Swivel jet nozzle DW-V... Twist nozzle DW-V-...-DR DS E 01. Jet nozzle and twist nozzle Preliminary remarks Jet nozzle DW N Swivel jet nozzle DW V Twist nozzle
More informationWorth noting. Introduction. Key figures. lindab architect. Picture 1. Architect Circum, Luna and Prisma.
Contact, Overview, Index Guideline heating and cooling Plexus Professor / Professor Plus Premum / Premax / Solus Architect Polaris I & S Plafond Podium Celo Cabinett Capella Carat Fasadium Atrium / Loggia
More informationHELLA. Linear slot diffuser. Ordering codes. HELLA - Linear diffuser. Linear Diffusers 1 / 18. Example of the ordering code HELLA B-0-0-AN
Linear Diffusers / 8 HELLA Linear slot diffuser Ordering codes HELLA - Linear diffuser HELLA - Number of slots... Diffuser length L (mm) ) Increment mm... Deflector colour Damper Diffuser construction
More informationMcQuay Climate Control. Water Source Heat Pump Horizontal. CC, CG, CW Vintage C, D. Last Manufactured: 1984
Replacement Parts List No. 055204000 Revision C 01/2017 McQuay Climate Control Water Source Heat Pump Horizontal CC, CG, CW 260-330 Vintage C, D Last Manufactured: 1984 To find your Daikin Applied parts
More informationFerrite Cores for Induction Welding
2005 Product Line atalog Ferrites and ssemblies for High Frequency Induction Welding Subsidiary of TT electronics plc Ferrite ores for Induction Welding F59 Typical Performance urves Ferrite Impeder Materials
More informationBNA Series. PLENUM FAN with Backward Wheels
BNA Series PLENUM FAN with Backward Wheels BNA Series BNA Series Plenum Fans Backward wheels Kruger Plenum Fans are designed for air handling applications where the fan operates unhoused within a plenum.
More informationERSATZTEILE RAS-14-18FSXN
ERSATZTEILE 1-00V/0Hz 7E331030 7E331031 7E331032 1FSXN 1FSXN 1 Side Cover L 17B13 A P2828 1 1 1 2 Side Cover R 17B13 A P2827 1 1 1 3 Side Cover 2 L 17F03722 A P288 1 1 1 Side Cover 2 R 17F0372 A P2887
More informationOUTDOOR UNITS. Introduction YMF-C. Introduction. Refrigerant
Introduction Introduction Refrigerant R407C R Series Y series (Heat Pump) R series (Air-cooling) Y series ( Only) Y series (Heat Pump) R series (Air-cooling) Y series ( Only) OUTDOOR UNITS Model Name -YMF-C
More informationMcQuay Climate Control Singer
Replacement Parts List No. 055204800 Revision B 01/2017 McQuay Climate Control Singer Vertical Water Source Heat Pump FC, FG, FW 240, 330, 400, 500 Vintages C, D Last Manufactured: 1986 To find your Daikin
More informationCONFIGURABLE CROSS-FLOW HEAT RECOVERY UNITS CADB/T-N Series
FILTERS F7 Compact heat recovery unit with cross-flow heat exchanger in 9 sizes from 500 m 3 /h to 8.350 m 3 /h. The casing is made from aluminium profile frame with double skinned 25 mm steel panels with
More informationPARTS CATALOG MUZ-FE09NA MUZ-FE09NA - 1 MUZ-FE09NAH MUZ-FE12NA MUZ-FE12NA1 MUZ-FE12NAH MUZ-FE18NA OUTDOOR UNIT. No. OBB543 REVISED EDITION-C.
SPLIT-TYPE AIR CONDITIONERS Revision C: H and FE12NAH have been added. Please void OBB543 REVISED EDITION-B. OUTDOOR UNIT PARTS CATALOG No. OBB543 REVISED EDITION-C Models - 1 H FE12NA FE12NA1 FE12NAH
More informationCDD/CDR. Single cone ceiling diffusers for supply air. Quick facts. Quick guide CDD/CDR A I R F L O W - S O U N D L E V E L
Single cone ceiling diffusers for supply air Quick facts Spread pattern can be shielded Used with commissioning box ALS Cleanable Adjustable slot Perforated diffuser face = CDD Imperforated diffuser face
More informationSinger. Incremental Comfort Systems. K, EK Vintage F. Last Manufactured: Replacement Parts List No Revision C 04/2012
Replacement Parts List No. 055231000 Revision C 04/2012 Singer Incremental Comfort Systems K, EK 07-15 Vintage F Last Manufactured: 1976 To find your Daikin Applied parts distributor, call 1-800-377-2787
More informationFlow rates to 485 l/min
FB Maximum pressure 0 bar Flow rates to 8 l/min Technical data Filter housing (Materials) ead: Cast iron (chemical heat treatment) ousing: Steel (chemical heat treatment) Bypass valve: Steel Check valve:
More informationFlow rates to 485 l/min
FB Maximum pressure 0 bar Flow rates to 8 l/min Technical data Filter housing (Materials) ead: Cast iron (chemical heat treatment) ousing: Steel (chemical heat treatment) Bypass valve: Steel Check valve:
More informationMODEL: WB009GMFI19HLD (120V) Wall Mount DC Inverter Fan Coil Unit 9,000 BTUH
MODEL: WB009GMFI19HLD (120V) Wall Mount DC Inverter Fan Coil Unit 9,000 BTUH No. Part Name Quantity BOM code List Price Remark 1 Panel assembly 1 201132890609 2 Air filter 2 201132890704 5 Display box
More informationMcQuay Climate Control Singer. Incremental. NE, NH, NR Vintages C, D. TYA, TAA Vintages A, B. Last Manufactured: 1999
Replacement Parts List No. 055233900 Revision D 08/2017 McQuay Climate Control Singer Incremental NE, NH, NR 07-18 Vintages C, D TYA, TAA 007-015 Vintages A, B Last Manufactured: 1999 To find your Daikin
More informationKM-2000SWE3 KM-2000SRE3
NO. ISSUED: REVISED: 71090 JUNE 7, 1994 AUG. 7, 2000 HOSHIZAKI STACKABLE CRESCENT CUBER MODEL KM-2000SWE3 KM-2000SRE3 (FINAL) PARTS LIST KM-2000SWE3 D-0 June, 1994 E-1 April, 1995 F-1 May, 1996 F-2 July,
More informationFlow rates to 485 l/min
FB Maximum pressure 0 bar Flow rates to 8 l/min Technical data Filter housing (Materials) ead: Cast iron (chemical heat treatment) ousing: Steel (chemical heat treatment) Bypass valve: Steel Check valve:
More informationGrille. Min. - max. dimensions
Min. - max. dimensions H L 0 00 75 00 Standard grilles are available with mm pitch within the above min. and max. sizes. Customized sizes available on request. Description is an adjustable single or double
More informationREPAIR PARTS. GPH14 H-SERIES R-410A Package Heat Pumps GPH1424H41AA GPH1430H41AA GPH1436H41AA GPH1442H41AA GPH1448H41AA GPH1460H41AA
REPAIR PARTS GPH14 H-SERIES R-0A Package Heat Pumps GPH1424HAA GPH1430HAA GPH1436HAA GPH1442HAA GPH1448HAA GPH1460HAA This manual is to be used by qualified technicians only. 2009 Goodman Manufacturing
More informationBASCO TYPE 500ES HEAT EXCHANGERS. ...world leaders in heat transfer technology
BASO YPE 500ES HEA EHAERS...world leaders in heat transfer technology Quality, Value, nnovation and Performance For over 60 years, AP Heat ransfer s commitment to these core principles is what sets us
More informationPELICAN Ceiling HF. Square extract air diffuser QUICK FACTS
Square extract air diffuser QUICK FACTS Perforated air diffuser front face Manages large extract airflows Flush design Designed for modular suspended ceilings Quick Access front face Can be combined with
More informationKrantz Components. Twist outlet DD-N... for ceiling installation. Air distribution systems
Krantz Components Twist outlet DD-N... for ceiling installation Air distribution systems DS E 0. Twist outlet Preliminary remarks and construction design Preliminary remarks Twist outlets for ceiling installation
More informationKrantz. RL-C2 radial slot outlet. Air distribution systems
RL-C2 radial slot outlet Air distribution systems DS E 04.1 Introduction The RL-C2 radial slot outlet with circular face generates a turbulent mixed flow. It is used for supply and return air distribution
More informationHigh Pressure fi lters
High Pressure fi lters FMM 00 series Maximum pressure up to 0 bar Flow rate up to l/min FHA 0 series Maximum pressure up to 60 bar Flow rate up to 0 l/min 9 High Pressure fi lters FILTER SIZING The correct
More informationUse. Worth noting. Key figures. Installation. lindab fasadium
Contact, Overview, Index Guideline heating and cooling Plexus Professor / Professor Plus Premum / Premax / Solus Architect Polaris I & S Plafond Podium Celo Cabinett Capella Carat Atrium / Loggia Regula
More informationPFI Closed circuit cooling towers
PFI Closed circuit cooling towers Key benefits Lowest energy consumption and total cost of ownership Year round reliable operation Ideal replacement unit with certified thermal performance PFI characteristics
More informationnufacturing Company, L.P San Felipe, Suite
REPAIR PARTS (2,3,4) Multi Zone Heat Pump Outdoor Unit 2MXS18GVJUAA 3MXS24JVJUAA 4MXS32GVJUAA nufacturing Company, L.P. 5151 San Felipe, Suite 500 www.amana-hac.com www.amana-hac.com This manual is to
More informationDBS315 1-phase SIDE CHANNEL BLOWERS
DBS15/ 1-phase DESCRIPTION Dutair blowers for pressure and vacuum are compact machines consisting of an electric motor with a built-on pump housing. The rotational speed of the impeller creates a high
More informationHigh Pressure fi lters. FHB series. Maximum pressure up to 320 bar - Flow rate up to 485 l/min. High Pressure fi lters
High Pressure fi lters FHB series Maximum pressure up to 0 bar - Flow rate up to 8 l/min 8 High Pressure fi lters FILTER SIZING The correct filter sizing have to be based on the variable pressure drop
More informationAir distribution systems. Linear whirl outlet WL...
Air distribution systems Linear whirl outlet WL... DS 0 E 1.013 Preliminary remarks Mode of operation The linear whirl outlet generates turbulent mixing ventilation. It can be installed on or in a wall
More informationVariable swirl diffusers
Swirl diffusers, Variable swirl diffuser OD- Application Diffuser is designed for air conditioning of rooms with floor to ceiling highs of to 0 m and high induction requirements. It is suitable for large
More informationKM-1600SWH KM-1600SRH KM-1600SWH3 KM-1600SRH3
NO. ISSUED: REVISED: 71193 OCT. 2, 2001 JAN. 27, 2003 HOSHIZAKI STACKABLE CRESCENT CUBER MODELS KM-1600SWH KM-1600SRH KM-1600SWH3 KM-1600SRH3 PARTS LIST KM-1600SWH L-0 June, 2001 M-0 Feb., 2002 M-1 Feb.,
More informationAir distribution systems. Radial outlet RA-N2...
Air distribution systems Radial outlet RA-N... DS E 0.01 Radial outlet RA-N Preliminary remark KRANTZ KOMPONENTEN radial outlets RA-N have fixed radial vanes and are available with circular or square face.
More informationAir Handling Unit. Konvent
Air Handling Unit Konvent Unbeatable advantages Konvent at a glance Technical Details Mistral S control Product overview Dimensions Benefits for you! Gentle temperature control To protect buildings and
More informationTangential Fans Series TW Impeller diameter 150 mm and 200 mm
Tangential Fans Series TW Impeller diameter mm and 0 mm 105 Corporate Drive, Suite E Spartanburg, SC 293 PO Box 2889, Spartanburg, SC 294 USA Tel: 864-599-63 Fax: 864-599-6344 e-mail: info@ltg-inc.net
More informationHigh Pressure fi lters. FHM series. Maximum pressure up to 320 bar - Flow rate up to 450 l/min. High Pressure fi lters
High Pressure fi lters FHM series Maximum pressure up to 0 bar - Flow rate up to 0 l/min 67 High Pressure fi lters FILTER SIZING The correct filter sizing have to be based on the variable pressure drop
More informationOdor Removal Filter Series AMF
Odor Removal Filter Series AMF Series AMF Odor Removal Filter efficiently removes odor in compressed air with an activated carbon element. The unit is designed for use in food processing, pharmaceutical,
More information473 Dew Point Hygrometer
High Performance Chilled Mirror Hygrometer With Cable Mounted Measuring Heads Highly precise chilled mirror dew point technology Cable mounted dew point and temperature measurement Aspirated and direct
More informationREPAIR PARTS. ARUF Aluminum Coil Air Handler
REPAIR PARTS ARUF Aluminum Coil Air Handler ARUF172916CA ARUF186CA ARUF193116CA ARUF303016CA ARUF363616CA ARUF364216CA ARUF374316CA ARUF486016CA ARUF496116CA This manual is to be used by qualified technicians
More informationAddendum to ARI Standard , Air Terminals September 2002
Addendum to ARI Standard 880-98, Air Terminals September 2002 The September 2002 Addendum to ARI Standard 880-98, Air Terminals, is comprised of only the shaded portions shown, which has been incorporated
More informationREPAIR PARTS. GPH13 "M" Series Horizontal Package Heat Pumps GPH1324M41AA GPH1330M41AA GPH1336M41AA GPH1342M41AA GPH1348M41AA GPH1360M41AA
REPAIR PARTS GPH13 "M" Series Horizontal Package Heat Pumps GPH1324MAA GPH1330MAA GPH1336MAA GPH1342MAA GPH1348MAA GPH1360MAA This manual is to be used by qualified technicians only. 2009 Goodman Manufacturing
More informationnufacturing Company, L.P San Felipe, Suite 500
REPAIR PARTS AVXC20 Inverter Air Conditioners AVXC200241AA AVXC200241AB AVXC200241AC AVXC200361AA AVXC200361AB AVXC200361AC AVXC200481AA AVXC200481AB AVXC200481AC AVXC200601AA AVXC200601AB AVXC200601AC
More informationConnections Standard. Description
Section Convectors Description Connections Standard without built-in valve or version with built-in valve Air vent, Drain Fixing Pressure versions, Fittings, Surface finishes, Special versions Heat output
More informationSlot diffusers. Slot diffusers, Round duct diffusers. Slot diffusers. Slot diffusers LD-13, LD-14
, Round duct diffusers D-, D- Application D- and D- slot diffusers are designed for the supply of air in rooms with floor to ceiling heights of.5 to m for supplying either cold or warm air, in particular
More informationNO: ISSUED: DEC. 7, 1999 REVISED: SEPT. 4, 2002 HOSHIZAKI MODULAR ICEMAKER F-2000MLF(-C) MODEL (FINAL) PARTS LIST
NO: 71135 ISSUED: DEC. 7, 1999 REVISED: SEPT. 4, 2002 HOSHIZAKI MODULAR ICEMAKER MODEL F-2000MLF(-C) (FINAL) PARTS LIST H-0 March 1998 J-0 December 1998 K-0 February 2000 K-1 June 2000 L-0 December 2000
More informationMAKING MODERN LIVING POSSIBLE. Thermostatic expansion valve Type TUB/TUBE and TUC/TUCE REFRIGERATION AND AIR CONDITIONING.
MAKING MODERN LIVING POSSIBLE Thermostatic expansion valve Type B/BE and C/CE REFRIGERATION AND AIR CONDITIONING Technical leaflet Thermostatic expansion valve, type B/BE and C/CE Contents Page Introduction........................................................................................
More informationHigh Pressure fi lters. FHB series. Maximum working pressure up to 32 MPa (320 bar) - Flow rate up to 485 l/min
High Pressure fi lters FHB series Maximum working pressure up to MPa (0 bar) - Flow rate up to 8 l/min High Pressure fi lters Introduction FILTER SIZING INDEX CALCULATION CORRECTIVE FACTOR Page Introduction
More informationAIR COOLED CONDENSING UNIT
EVOLUTION SERIES AIR COOLED CONDENSING UNIT OUTDOOR AIR COOLED CONDENSING UNIT ORIGINAL MANUFACTURED EQUIPMENT Evolution Series BA-503-3 AUS Evolution Air Cooled Condensing Unit Series Content Page Explanation
More informationSwirl diffusers, Variable swirl diffusers
0 Variable swirl diffusers SLOT IFFUSERS, ROUN UCT IFFUSERS SWIRL IFFUSERS, VARIABLE SWIRL IFFUSERS CIRCULAR IFFUSERS, SQUARE IFFUSERS VENTILATING GRILLES, VENTILATING VALVES, Variable swirl diffusers
More informationALUMINIUM CENTRIFUGAL FANS. 4 x M6 x OUTLET x M6 x 20
DESCRIPTION Dutair LK-series industrial ventilators consist of a robust body made from die-cast aluminium alloy. Impellers are made of extruded aluminium. The asynchronous electric motors are maintenance
More informationALUMINIUM CENTRIFUGAL FANS x M6 x x M6 x 16
LK4 DESCRIPTION Dutair LK-series industrial ventilators consist of a robust body made from die-cast aluminium alloy. Impellers are made of extruded aluminium. The asynchronous electric motors are maintenance
More information2/S12 DIFFUSER FOR HORIZONTAL OR VERTICAL DISCHARGE DHV. v 3.3 (en)
2/S12 v (en) DIFFUSER FOR HORIZONTAL OR VERTICAL DISCHARGE DHV 6 7 wwwklimaopremahr wwwklimaopremahr TABLE OF CONTENTS Horizontalvertical diffuser 9 Ordering key 1 Selection diagrams 1 DHV Ceiling diffuser
More informationPG-200/PG-208 PRESSURE GAUGES P G G P P
Digital 3 1/2 digits monitor Set button for switch output HI or LO (PG-200) (PG-208) Digital 3 1/2 digits Power switch LO setting VR for switch output LO HI setting VR for switch output HI SPAN adjustment
More information