1 FOR INDUTRIE, BUILDING AND PROCE ApPLICATION APpLICATION Product Features Energy aver Low Noise Level Low Drift Loss Quake proof Design Guaranteed Thermal Performance APC ERIE COUNTER FLOW ROUND TYPE ALPHA VINA COOLING TOWER INDUTRY
2 Induced Draft Counter Flow Cooling Tower (Bottle Type)
3 TRUCTURE INDUCED DRAFT COUNTER FLOW 1 TRUCTURE 1. MOTOR & FAN DRIVE. AIR INLET MEH. TOWER CAE. FAN BLADE & HUB. PRINKLER HEAD 6. DRIFT ELIMINATOR. FILLER 8. WATER BAIN 9. FILLER UPPORT. FAN GUARD 11. MOTOR UPPORT 1. LADDER 1. AUX. UCTION TANK 1. BAIN UPPORT Cooling Water Flow Air Flow MATERIAL PECIFICATION MODEL APC MOTOR FAN DRIVE FAN BLADE /6V.Ph /Hz /V.Ph /Hz PEED REDUCER DIRECT DRIVE AB ALUMINIUM ALLOY CAING PRINKLER HEAD ELIMINATOR AB PECIAL ALUMINIUM ALLOY WITH TAINE TEEL HAFT NONE FILLER PVC AIR INLET MEH LADDER HDPE NONE MOTOR UPPORT CAING UPORT BAIN UPPORT TRAINER WATER BAIN TAINE TEEL MEH PVC HDPE : HOT DIPPED GALVANIZED TEEL : TAINLE TEEL : POLYVINYL CHLORIDE : HIGH DENITY POLYETHYLENE : FIBER GLA REINFORCED PLATIC
4 DIMENION & PIPE CONNECTION Dimension Tower Model APC (RT) Cooling Capacity (Kcal/hr) Nominal W.Flow (l/min) Pipe Connection Fan Assembly Pump Head Fan A.Volumn (M) D mm (m/min) D Inlet Outlet O.flow Drain (Ba) (Q) Motor (Hp) 8 1/ / / 1. H / / / / ½ ½ ½ ½ ½ ½ APC ~0RT APC 1~RT APC ~RT APC 0~0RT APC RT APC 0~1RT APC ~0RT
5 FOUNDATION Foundation Dimensions Anchor Bolt Weight Tower Model APC (RT) D1 W B A C E F F' h ize () Length Quantily () (pcs) Dry (kg) Operating (kg) M M APC ~RT APC 0~RT APC 0~1RT APC 1~RT APC 0~0RT APC ~0RT
6 TOWER PERFORMANCE W.B Temp Dif Temp Model APC 90C C C C 0C C 90C C C C C W.B AMBIENT WET BULB TEMPERATURE TEMP DIF: WATER INLET TEMPERATURE WATER OUTLET TEMPERATURE Technical information for requirements. 1. Circulating water volume (LPM or M/Hr). Tower inlet water temperature (oc). Tower outlet water temperature (oc). Wet Bulb temperature or Dry Bulb temperature (oc) and relative humidity (%). Area size and site condition 6. Water quality. Power upply: voltage and frequency 8. Purpose of tower usage 9. Any other items of preference
7 INTALLATION INTRUCTION 1.Location selection a. Either indoor or outdoor place is appropriate for a cooling tower installation b. In case of cooling towers are installed, there should be appropriate spaces between the first cooling tower and the second one.. Position a. Make sure that the tower is placed vertically because inconsistent sprinkle will lower the cooling tower efficiency. ee pictures below. b. Tighten the anchor bolts. >1/D c. Keep proper distance between a cooling tower and the enclosures Incorrect. Piping a. The inlet and outlet pipes must be installed lower than the pipe connections of the water sumps. ee pictures below. H Correct d. In case of multi cells installed in Iine, should be concerned about the air flow directions. >1/ D >1/D D e. Avoid any places where corrosive gases exist including chimneys and host spring f.keep cooling tower away from hot temperature place. g. Keep cooling tower away from the smoke and dusty area. h. Keep cooling tower away from high voltage line or a transformer. Correct Incorrect b. The size of pipe should be as same as the pipe connections of the water sumps. A smaller size one will drop the cooling tower efficiency and the larger size pipe will waste the material. c. The circulating pump must be located below the water sump under normal operation. ee pictures below. P P Correct Incorrect d. cooling towers which operate by a pump need to be place equally in order to balance the water level in both cooling towers. correct correct correct correct OUND LEVEL Correct 1 e. High pressure flexible tubes must be used at the joists of circulating inlets and outlets with sizes over inches (mm) to avoid some vibration from the piping and prevent the water basin breaks which may cause by improper piping installation. m 1 m W 1.m Hz P 1 POITION POITION POITION 1 MODEL APC 1 0 L = DIAMETER OF FAN OR 1. m WHICHVER I LARGER UNIT : dba. Other: a. After the installation is complete, check that there are no tools or any other objects left in the tower b. Make sure that both piping and water basin are not leaking. c. When the pressure of make up water is low, install either a water tank highter than the water level or install a water make up pump somewhere in the piping system to obtain more water pressure. 6
8 THE BET OLUTION FOR COOLING TOWER HO CHI MINH CITY OFFICE No 1/A, Tran Xuan oan Road, Tan Hung Ward, District, HCM City, Viet Nam Tel: (+88) 11/116 Fax: (+88) 11 HA NOI CITY OFFICE No 6 Co Bi Road, Co Bi Ward, Gia Lam Dictrict, Ha Noi City, Viet Nam Tel: (+8) 66/ Fax: (+8) 66 Gold@coolingtower.vn FACTORY Van An 1 IDZ, Luong Phong Ward, Hiep Hoa Dist, Bac Giang Province, Viet Nam Tel: (+8) 68 Fax: (+8) Pro@coolingtower.vn WEBITE: Coppyright C 11 Alpha Vina Cooling Tower Industry All right reserved Made in Viet Nam
CROSS FLOW COOLING TOWER
CROSS FLOW COOLING TOWER LUCKY GREEN THAI INDUSTRIES CO LTD Material Specification Model LGX 80 00 0 00 0 300 30 400 00 600 700 800 000 Motor Totally enclosed Totally enclosed fan cooled Driving System
More informationSeries 3000 and XE-Series Engineering Data
Series 3000 and XE-Series Engineering Data A C A U S T R A L I A Series 3000 and XE-Series Engineering Data The NEW era of Series 3000 and XE-Series Cooling Towers continue to exceed the industry standard
More informationTHE ENERGY 68,SAVING TDVI. exible Combine Modular 24, 26, 28, 30, 32, 34, 36, 38, 40, 42, 44 HP 60, 62, 64, 66 HP
I N V E RT E R ion Range exible Combine Modular TDV I TDV I TDV I INVERTER INVERTER INVERTER 14, 16, 18, 20, 22 HP TDV I 24, 26, 28, 30, 32, 34, 36, 38, 40, 42, 44 HP INVERTER INVERTER INVERTER TDV I INVERTER
More informationPFI Closed circuit cooling towers
PFI Closed circuit cooling towers Key benefits Lowest energy consumption and total cost of ownership Year round reliable operation Ideal replacement unit with certified thermal performance PFI characteristics
More informationSerie B2.1. Flanged ductile iron ball valve. made in. Application fields. Shut-off valves E U R O P E. 18
erie B. Flanged ductile iron ball valve BRanDOni made in E U R O P E Application fields WATER CONdITIONING GA EATING INdUTRY FIRE FIGTING www.brandoni.it erie B. eries B. valves are shut-off ball valves
More informationCOOLING TOWER MODEL IN MNR
COOLING TOWER MODEL IN MNR 1 COOLING TOWER MODEL The cooling tower model used in Liu s study [2] was adapted from the model developed by Eric Weber (1988). One modification is the use of a counterflow
More informationXHDU Cassette type fan-coils for double/four pipe connections 1,98-14 kw HYDRONIC TERMINALS
HYDRONIC TERMINALS XHDU 402 1203 Versions XHDU 2T XHDU-R 2T XHDU 4T XHDE 2T Single coil for double pipe connections Single coil for double pipe connections with heater Double coil for four pipe connections
More informationSINGLE. Technical Data Book. Big Ceiling for Europe (R410A, 50Hz, H/P) Model : AC***JNCDEH (ODU: AC***JXAD*H)
SINGLE Technical Data Book Big for Europe (R4A, Hz, H/P) Model : AC***JNCDEH (ODU: AC***JXAD*H) History Version Modification Date Remark Ver.1. Release SINGLE Big for Europe.4.3 Ver.1.1 Modification for
More informationExperimental investigation of the performance of a Parabolic Trough Collector (PTC) installed in Cyprus
Archimedes Solar Energy Laboratory (ASEL) Experimental investigation of the performance of a Parabolic Trough Collector (PTC) installed in Cyprus Soteris A. Kalogirou Department of Mechanical Engineering
More informationTangential Fans Series TW Impeller diameter 150 mm and 200 mm
Tangential Fans Series TW Impeller diameter mm and 0 mm 105 Corporate Drive, Suite E Spartanburg, SC 293 PO Box 2889, Spartanburg, SC 294 USA Tel: 864-599-63 Fax: 864-599-6344 e-mail: info@ltg-inc.net
More informationGS4000 DATASHEET JUNHO 2013
GS4000 DATASHEET JUNHO 2013 www.severntrentservices.com Biochem T70GS4000 Chlorine Dioxide Generator - 2g/day - 10g/h System Advantages Dosage Flexibility The generator produces a chlorine dioxide solution,
More informationEUROVENT 8/12 SOUND TEST METHOD FOR DUCTED FAN COIL UNITS. FCP 2008 testing procedures FCP acoustical test method pag. 1
EUROVENT 8/12 SOUND TEST METHOD FOR DUCTED FAN COIL UNITS FCP 2008 testing procedures FCP acoustical test method pag. 1 CONTENTS 1 - PURPOSE... 3 2 - NORMATIVE REFERENCES... 3 3 - DEFINITIONS... 3 3.1
More informationAC axial compact fan
ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-767 Mulfingen Phone +9 798 8- Fax +9 798 8- info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen County court Stuttgart HRA 59
More informationPHOS 25 Downlight LED PROJECTOR
PHOS 25 Downlight LED PROJECTOR SPECIFICATIONS Item: PHOS 25 Downlight Body:... Steel / Aluminium Available Colours:....... White / Black / Silver Weight:.. 3.65 kg Ballast:...... External Ballast Included
More informationBV SERIES. VERTICAL BLOWER COIL UNITS Nominal Sizes 2 thru 10 Ton
BV SERIES VERTICAL BLOWER COIL UNITS Nominal Sizes 2 thru 10 Ton MAGIC AIRE BV SERIES FAN COILS ARE ETL LISTED TO U.S. AND CANADIAN SAFETY STANDARDS AND ARE ASSEMBLED TO ORDER FOR COMPETITIVE DELIVERY.
More informationProduct Data. CAPVU Evaporator Coil A Coil --- Uncased Upflow, Downflow CAPVU
CAPVU Evaporator Coil A Coil --- Uncased Upflow, Downflow Product Data CAPVU A06002 The CAPVU evaporator coils incorporate proven standards for reliable system operation and performance throughout the
More information3 Energy Exchange in Turbomachines
3 Energy Exchange in Turbomachines Problem 1 The solved and unsolved examples of this chapter are meant to illustrate the various forms of velocity triangles and the variety of the turbomachines. In addition,
More informationALUMINIUM CENTRIFUGAL FANS. 4 x M6 x OUTLET x M6 x 20
DESCRIPTION Dutair LK-series industrial ventilators consist of a robust body made from die-cast aluminium alloy. Impellers are made of extruded aluminium. The asynchronous electric motors are maintenance
More informationALUMINIUM CENTRIFUGAL FANS x M6 x x M6 x 16
LK4 DESCRIPTION Dutair LK-series industrial ventilators consist of a robust body made from die-cast aluminium alloy. Impellers are made of extruded aluminium. The asynchronous electric motors are maintenance
More informationT20WN. Data Sheet. Torque transducers. Special features. Installation example with bellows couplings. B en
T20WN Torque transducers Data Sheet Special features - Nominal (rated) torques 0.1 N m, 0.2 N m, 0. N m, 1 N m, 2 N m, N m, 10 N m, 20 N m, 0 N m, 100 N m, 200 N m - Accuracy class: 0.2 - Contactless transmission
More informationCooling Water Flow Regulator
Temperature controlled, indirectly and directly actuated diaphragm valves / seat valves Port size G 3/8 to G DN 0 to DN 0 ontinuous regulation High accuracy No auxiliary energy required Technical data
More informationChapter 3: Fundamentals of Mechanics and Heat. 1/11/00 Electromechanical Dynamics 1
Chapter 3: Fundamentals of Mechanics and Heat 1/11/00 Electromechanical Dynamics 1 Force Linear acceleration of an object is proportional to the applied force: F = m a x(t) F = force acting on an object
More informationTurbine Meter TRZ 03 PRODUCT INFORMATION. Reliable Measurement of Gas
Turbine Meter TRZ 0 PRODUCT INFORMATION Reliable Measurement of Gas TURBINE METER TRZ 0 Method of operation, Construction Method of operation The TRZ 0 turbine meter is a flow meter suitable for gas measurement
More informationCNA-CNB. Centrifugal fans
NA-NB entrifugal fans Product facts Product Single-inlet low-pressure fans with backward-curved blades. Use In industrial ventilation systems for uncontaminated, non-corrosive air, max. 70 º, where a low
More informationAir Cooler Industry AC-LN 1-7 / ACA-LN 2-7 / ACAF-LN 2-7
ir ooler Industry -LN -7 / -LN -7 / F-LN -7 Symbol General The -LN -7 air cooler series can be used in all areas where either oil or water-glycol is to be cooled with air. The coolers with an axial fan
More informationPTF30 Series. Features. Ordering information. G 6 N N F8 (0 to 5 kgf/cm 2 ) PTF30
eries Features Best pressure transmission solution for small and middle sized project such as indoor heating and air conditioning, water and sewer, or incinerator, etc. Improves noise resistance and minimize
More informationMETALLIZED POLYPROPYLENE AC FILTERING CAPACITORS
METALLIZED POLYPROPYLENE AC FILTERING CAPACITORS Technology looking ahead With the new LNF series a new level of safety for the AC capacitors has been reached: Active safety: When the capacitor is stressed
More informationISEmax CAM40/CAS40. Technical Information
Technical Information Online measurement of nutrient parameters Ion-selective electrode system for the continuous measurement of ammonium and nitrate Application The ion-selective electrode system works
More informationSUBMITTAL DATA: MXZ-3C30NA MULTI-INDOOR INVERTER HEAT-PUMP SYSTEM
Job Name: System Reference: SUBMITTAL DATA: MXZ-3C30NA MULTI-INDOOR INVERTER HEAT-PUMP SYSTEM M-SERIES Date: GENERAL FEATURES Quiet Operation Optional base pan heater to prevent ice in drain pan Limited
More informationFVBSS fixed volume bottle
N FVBSS fixed volume bottle Sampling System The SENSOR Fixed Volume Bottle Sampling System (FVBSS) provides a repeatable fixed volume of sample during each sampling process without stopping flow of the
More informationAC axial compact fan
ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-7467 Mulfingen Phone +49 798 8-0 Fax +49 798 8-0 info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen County court Stuttgart HRA
More informationOdor Removal Filter Series AMF
Odor Removal Filter Series AMF Series AMF Odor Removal Filter efficiently removes odor in compressed air with an activated carbon element. The unit is designed for use in food processing, pharmaceutical,
More informationKjeltec 2300 Analyzer Unit
Kjeltec 2300 Analyzer Unit Automatic distillation and approved colorimetric titration for analysis of Kjeldahl nitrogen/protein, ammonium- nitrogen, TKN, Direct distillation (DD), volatile acids/ bases
More informationMICRO-HYDRO INSTALLATION SIZING CALCULATIONS Jacques Chaurette eng. January 17, 2008
MICRO-HYDRO INSTALLATION SIZING CALCULATIONS Jacque Chaurette eng. January 7, 008 Calculation for micro-hydro ine jet impact elocity are baed on the ame ort of calculation done for pump ytem, except there
More informationVRF Technical Data Book
VRF Technical Data Book DVM S for Euro_ET (R4A, Hz, HP) Model : Premium (Compact / Energy Efficiency) Type Standard Type History Version Modification Date Remark Ver. 1. Release DVM S (R4A, Hz, HP) for
More informationCMA - B - C - D - CMR
Cast iron self-priming electric pumps. APPLICATIONS Pressure boosting domestic plants Small-scale irrigation Moving non-aggressive liquids for civil and industrial use Washing plants Washing vehicles CMA-B-C-D
More informationDuct design. King Abdulaziz University. Major losses in duct
King Abdulaziz Univerity College o Engineering Mechanical Engineering MEP 5 Rerigeration & Air Conditioning June 009 Duct deign Air low in duct Major and Minor Loe in Duct Lo coeicient or ome itting Equivalent
More informationALUMINIUM CENTRIFUGAL FANS. 4 x M6 x 16
DESCRIPTION Dutair BCT-series aluminium centrifugal fans with open die-cast aluminium impellers and forward curved blades are suitable for material transport and high pressure applications. The asynchronous
More informationIMPROVING THE PERFORMANCE OF AN AC UNIT USING CFD
3 rd HVAC Contracting Conference Evolution of HVAC Industry International Hotel Doha The City November 25-26, 2018 IMPROVING THE PERFORMANCE OF AN AC UNIT USING CFD F. Moualled Mechanical Engineering Department
More informationALUMINIUM CENTRIFUGAL FANS M20 4 x M5 x 10 INLET. 4 x M5 x 12
BCT61 DESCRIPTION Dutair BCT-series aluminium centrifugal fans with open die-cast aluminium impellers and forward curved blades are suitable for material transport and high pressure applications. The asynchronous
More informationPopulations effected by flood top ten districts
2050 - Populations effected by flood top ten districts 14 Extreme A2 Extreme A2 with dyke District Area (Ha) Population 2050 People affected Percent area affected People affected Percent area affected
More informationASPT Series. Multi-Position, Internal TXV. Air Handler 1½ to 5 Tons
Series Multi-Position, Internal TXV Product Features Internal factory-installed thermal expansion valves for cooling and heat pump applications Direct drive, multi-speed ECM blower motor All-aluminum evaporator
More informationTwin City Fan Companies. Fan System Effects
Fan System Effects Outline Fan Testing Review Definition of System Effect Old ASHRAE guidelines AMCA 201 System Effect Factors Examples Demonstration Aimed at the fan system designer There are two goals:
More informationTPH. 60Hz. Standard mode TPH 4T 2K. Code TPH 4T 2K S F A H
C US NSF/ANSI TPH Applications: The TPH Series are modernly designed with quiet and high efficient operation pumps, suitable for dependable water transfer, circulating or booster service. -Industrial circulation
More informationPARTS CATALOG MXZ-3C54VA - E1 MXZ-3C68VA - E1 MXZ-4C71VA - E1 MXZ-4C80VA - E1 MXZ-5C100VA - E1 MXZ-6C120VA - E1 OUTDOOR UNIT. No. OBB584 HFC.
SPLIT-TYPE AIR CONDITIONERS OUTDOOR UNIT PARTS CATALO HFC utilized R0A OBB Models MXZ-CVA - E MXZ-C6VA - E MXZ-CVA - E MXZ-C0VA - E MXZ-C00VA - E MXZ-6C0VA - E CONTENTS. PARTS LIST. OPTIONAL PARTS SERVICE
More informationLentis Pai/Associate Director/Wiwynn
Two Phase Rack Level Liquid Cooling Solution Lentis Pai/Associate Director/Wiwynn A g e n d a Existing Chassis Level Solution Wiwynn Two Phase Immersion Cooling Rack Level Liquid Cooling Solution Overview
More informationINTRODUCTION. Electromagnetic induction is a heating technique for electrical conductive materials. Applications:-
INTRODUCTION Electromagnetic induction is a heating technique for electrical conductive materials. Applications:- Melting Spherodizing Sintering Heat Treating of Light Metals Advantages And Disadvantages
More informationCalio-Therm NC Type Series Booklet
High-efficiency Drinking Water Pump Type Series Booklet Legal information/copyright Type Series Booklet All rights reserved. The contents provided herein must neither be distributed, copied, reproduced,
More informationDESIGN AND FABRICATION OF MINI DRAFT COOLING TOWER
DESIGN AND FABRICATION OF MINI DRAFT COOLING TOWER 1 Mahendran 2 Mukund, 3 Muralidharan, Address for Correspondence 1 Asst. Prof., Mechanical Engineering, 2 Student, K. Ramakrishnan college of Technology,
More informationPlant Design LECTURE 8: REBOILER CIRCUIT DESIGN. Daniel R. Lewin Department of Chemical Engineering Technion, Haifa, Israel
054410 Plant Design LECTURE 8: REBOILER CIRCUIT DESIGN Daniel R. Lewin Department of Chemical Engineering Technion, Haifa, Israel Ref: Kern, R. Thermosyphon Reboiler Piping Simplified, Hydrocarbon Processing,
More informationR13 SET - 1 '' ''' '' ' '''' Code No RT21033
SET - 1 II B. Tech I Semester Supplementary Examinations, June - 2015 THERMODYNAMICS (Com. to ME, AE, AME) Time: 3 hours Max. Marks: 70 Note: 1. Question Paper consists of two parts (Part-A and Part-B)
More informationOil / Air Cooling Unit Type 3.01.xx.xx
Type 3.01.xx.xx 335 309 44 213 426 339 339 9 213 219 108 12 380 Application Technical Material Fitting note Cooling of: Oil, HFA, HFB, HFC, HFD liquids up to = 100 x 10-6 m 2 /s water/glycol 65:35, By
More informationAIR CONDITIONER (SPLIT TYPE) SERVICE MANUAL
AIR CONDITIONER (SPLIT TYPE) SERVICE MANUAL FILE No. A10-023-1 REVISION 1 : Mar.2012 Re-edit version.( file volume down) Contents have NOT been changed. Model name: RAS-M10PKVP-E RAS-M13PKVP-E RAS-M16PKVP-E
More informationSamos SI E1/E2
Samos SI E/E Samos SI E Description Busch Samos SI regenerative blowers are designed for either pressure or vacuum. They are available in single and two stage models so they can operate over a wide range
More informationGB5BM Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Air Handler WARRANTY
TECHNICAL SPECIFICATIONS GB5BM Series Air Handler 13 SEER Residential System 18,000-60,000 Btuh (Heat Pump & Air Conditioner) The GB5BM Series of air handlers, when combined with our heat pump or air conditioner,
More informationSUBMITTAL DATA: MXZ-5C42NA MULTI-INDOOR INVERTER HEAT PUMP SYSTEM
Job Name: System Reference: SUBMITTAL DATA: MXZ-5C42NA MULTI-INDOOR INVERTER HEAT PUMP SYSTEM M-SERIES Date: GENERAL FEATURES Quiet Operation Optional base pan heater to prevent ice in drain pan Limited
More informationEFFICIENT 13 SEER HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz
ENVIRONMENTALLY SOUND REFRIGERANT N4H3 Performance Series Product Specifications EFFICIENT 13 SEER HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase,
More informationENVIRONMENTALLY SOUND R 410A REFRIGERANT
ENVIRONMENTALLY SOUND REFRIGERANT N4H3 Performance Series Product Specifications EFFICIENT 13 SEER HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase,
More informationApplication Your benefits
Technical Information CCS140 and CCS141 Sensors for free chlorine Amperometric, membrane-covered sensors for installation in the CCA250 flow assembly Application Oxidizing agents such as chlorine or anorganic
More informationDRIFTER PLOW-IN-A-BOX
DRIFTER PLOW-IN-A-BOX ASSEMBLY / OWNER S MANUAL Part No: 10-0550 OPERATING INSTRUCTIONS Congratulations! You ve just purchased one of the industry s top plow systems. The DRIFTER Plow System works great
More informationResidual Chlorine Monitor
Data Sheet SS/AW00 Issue Residual Chlorine Monitor AW00 Total and Free Residual Chlorine Measurement add potassium iodide to reagent to convert free chlorine measurement to total chlorine Reagentless Operation
More informationInverter Multi-Split System
Inverter MultiSplit System Specifications Inverter MultiSplit Fan coil unit Fan Coil Unit Model RAVMS3KCVT RAVMS3KCVT RASMS3KCVT RAVM22S3KCVT RAVM24S3KCVT Standard Cooling Capacity (btu/hr) 9,212 12,624
More information3 Port, 2-Ton Outdoor Heat Pump
Job Name: Tag# Submittal Data Sheet 3 Port, 2-Ton Outdoor Heat Pump 3MXS24NMVJU Efficiency SEER EER HSPF Non-Ducted 17.9 12.7 12.5 Ducted 14 9.7 8.2 Mixed 15.95 11.2 10.35 Performance Cooling (Btu/hr)
More informationSECTION 1 - WHAT IS A BTU METER? BTU's = Flow x ΔT Any ISTEC BTU Meter System consists of the following main components:
SECTION 1 - WHAT IS A BTU METER? ISTEC BTU Meters measure energy usage by multiplying flow rate and temperature difference. As the water (or other liquid) passes through these lines, the multi-wing turbine
More informationR- 410A R-22 Size (tons) Shipping Weight (lbs) WLAU184AA 1-1/ WLAU182AA 1-1/ WLAU244AA. Model /2
EVAPORATOR COILS A COIL - UNCASED R- 410A or R- 22 SYSTEMS 1 1/2 5 Tons WLAU Use of the AHRI Certified TM Mark indicates a manufacturer s participation in the program. For verification of certification
More informationContents. Identification LHC. Horizontal split case pumps. Type key. Identification Type key
Contents dentification Type key Product data ntroduction Applications Features and benefits Performance range pole pole pole Construction Sectional drawing Construction features Test pressure Operating
More informationVane pumps General catalog Single, double & triple T7 - T67 - T6C series
Vane pumps General catalog ingle, double & triple T7 - T7 - TC series Publ. - EN7 - D 9 / / FB Replaces : - EN7 - C L - 7 - VANE PUMP - GENERAL CATALOG GENERAL General characteristics................................................
More informationTheory. Humidity h of an air-vapor mixture is defined as the mass ratio of water vapor and dry air,
Theory Background In a cooling tower with open water circulation, heat is removed from water because of the material and heat exchange between the water and the ambient air. The cooling tower is a special
More informationASTM upvc Schedule 80
ASTM upvc PRESSURE PIPING SYSTEM SPECIFICATION Pipes Standards & Quality Sch. 80 pipe is manufactured to comply with NSF Standard 61, CSA B 137.3 and ASTM D1785, consistently meeting the Quality Assurance
More informationWISE Damper. Active damper for Swegon s WISE System for demand-controlled ventilation QUICK FACTS
Active damper for Swegon s WISE System for demand-controlled ventilation QUICK FACTS Variable or constant flow regulation or constant pressure regulation Wireless communication via radio Integrated sensor
More informationSVH with HYDROVAR (HVL range)
SVH with HYDROVAR (HVL range) SVH-HVL Rev. B Ed.9/1 (EN) SVH SERIES (e-sv WITH HYDROVAR) Background and context For all pumping needs in commercial or residential building and in industry applications,
More informationFluid-structure coupling analysis and simulation of viscosity effect. on Coriolis mass flowmeter
APCOM & ISCM 11-14 th December, 2013, Singapore luid-tructure coupling analyi and imulation of vicoity effect on Corioli ma flowmeter *Luo Rongmo, and Wu Jian National Metrology Centre, A*STAR, 1 Science
More informationAC axial fan. Limited partnership Headquarters Mulfingen Amtsgericht (court of registration) Stuttgart HRA
ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-767 Mulfingen Phone +9 798 8- Fax +9 798 8- info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen Amtsgericht (court of registration)
More informationDM70 Hand-Held Dewpoint Meter for Spot-Checking Applications
DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications The Vaisala DRYCAP Hand-Held Dewpoint Meter DM70 offers accurate and fast measurement for industrial dewpoint applications, such as compressed
More information42C/V. Fan Coil Unit 42C/V
2/V Fan oil Unit 2/V arrier makes the world a better place to live by creating a comfortable, productive and healthy environment regardless of climate. It is our mission is to be customer s first choice
More informationB6VMAX Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS
TECHNICAL SPECIFICATIONS B6VMAX Series Air Handler with TXV 13-19 SEER Residential System 18,000-60,000 Btuh (Heat Pump & Air Conditioner) R-410A Refrigerant The B6VMAX Series of air handlers, when combined
More informationPHOS 15 LED PROJECTOR
PHOS 15 LED PROJECTOR SPECIFICATIONS Item:.. PHOS 15 Body:.... Aluminium Available Colours:... White / Black / Silver Weight:.... 1.9 kg On / Off Switch:..... Not Available Environmental Conditions:.....
More informationAME Model. (1) Rated flow (l/min (ANR)) Port size (Nominal size B) Weight (kg)
Super Mist Separator Series AME Series AME separates and absorbs aerosol state fine oil particles in compressed air and changes the oil lubricating compressed air to oilless equivalent air. It should be
More informationSF6 Gas Standard Capacitors
TYL series SF6 Gas Standard Capacitors levels up to 95% without condensation. We use special stainless steel to permit the prefect temperature and voltage coefficient stability. The capacitor is provided
More informationSafety Precautions WARNING If critical situations that could lead to user s death or serious injury is assumed by mishandling of the product.
Safety Precautions Observe the following notices to ensure personal safety or to prevent accidents. To ensure that you use this product correctly, read this User s Manual thoroughly before use. Make sure
More information214'-7" Hook Height L1 114'-10" 22,025# Version "A" (With TSK 212 Section) HOOK HEIGHT ft/m TOWER TYPE TS TSK 212
PEINER SK 415 Hammerhead Tower Crane 22,025 44,050 lbs. (10 20 t) Lifting Capacity* SPECIFICATIONS C-L of hook to end of Jib 4'-10" (2) PART 33'-2" 7'-7" (4) PART BG 73'-2" TSK 214'-7" Height L1 114'-10"
More informationLow Inductance Ceramic Capacitor (LICC)
Low Inductance Ceramic Capacitor (LICC) LICC(Low Inductance Ceramic Capacitor) is a kind of MLCC that is used for decoupling in High Speed IC. The termination shape of LICC is different from that of MLCC.
More informationSPECIFICATION SS 51/9 400KV COUPLING CAPACITORS FOR POWER LINE CARRIER SYSTEM
INDEPENDENT POWER TRANSMISSION OPERATOR S.A. TNPRD/ SUBSTATION SPECIFICATION & EQUIPMENT SECTION January 2017 SPECIFICATION SS 51/9 400KV COUPLING CAPACITORS FOR POWER LINE CARRIER SYSTEM I. SCOPE This
More informationOverall Heat Transfer Coefficient
Overall Heat Transfer Coefficient A heat exchanger typically involves two flowing fluids separated by a solid wall. Heat is first transferred from the hot fluid to the wall by convection, through the wall
More informationSTATE OF COLORADO DESIGN CRITERIA FOR POTABLE WATER SYSTEMS WATER QUALITY CONTROL DIVISION. Price: $5.00. Revised March 31, 1997
STATE OF COLORADO DESIGN CRITERIA FOR POTABLE WATER SYSTEMS WATER QUALITY CONTROL DIVISION Revised March 31, 1997 Price: $5.00 a. an arrangement where the water pipe to be injected with chlorine enters
More informationSelection of jack size No. 5 Check again with ball screw jack Type J-B. Yes. Set the hand wheel radius if the screw jack is to be used for manual operation. Yes. Yes. Specification Select temporarily the
More informationChimney Sizing. Project Name: Location: Type Appliance: Hot Water Heater Incinerator. LP Gas #2 Oil #6 Oil Wood/Coal Waste (Type ) Appliance Input:
Chimney Sizing Project Name: Location: Type Appliance: Type Fuel: Appliance Input: Boiler Hot Water Heater Incinerator Natural Gas LP Gas #2 Oil #6 Oil Wood/Coal Waste (Type ) BTU Hp Lbs/hr Height Above
More informationAC axial fan. Limited partnership Headquarters Mulfingen Amtsgericht (court of registration) Stuttgart HRA
ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-767 Mulfingen Phone +9 798 8-0 Fax +9 798 8-0 info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen Amtsgericht (court of registration)
More informationflexible couplings for pipe repair
A R P O L R E P flexible couplings for pipe repair 1 TABLE OF CONTENTS Advantages and Installation Arpol Repair Systems Nominal charts Material specifications Gaps between pipe ends Outside Diameter tolerances
More informationIP64 WARRANTY UNIVERSAL LIGHT 15-24W.
UNIVERSAL LIGHT 15-24W www.trulygreensolutions.com 3 MODELS AVAILABLE IN 15W / 19W / 24W EXPECTED LIFE OVER 85,000 HRS Drainage holes guide water away Features 5 YEAR IES FILES @ www.trulygreensolutions.com
More information4HP13 PRODUCT SPECIFICATIONS 13 SEER SPLIT SYSTEM HEAT PUMP WARRANTY
4HP13 PRODUCT SPECIFICATIONS 13 S SPLIT SYSTEM HEAT PUMP FORM NO. 4HP13-100 (07/2014) R410A Refrigerant High-quality condenser coil with copper tubing and enhanced louvered fin for maximum heat transfer
More informationInstallation Instructions
PACKAGE CONTENTS ITEM QUANTITY Enthalpy Sensor (Part No. HH57AC078) No. 6B, 3 4-in. long Sheet Metal Screw 2 Blue Wire Assembly (256-in. long with 4-in. quick-connect fitting)* Violet Wire Assembly (256-in.
More informationAssembly and Maintenance manual according to regulation DIN 82079
Assembly and Maintenance manual according to regulation DIN 82079 ESORB Version 4.16 Part 1 Information to the manufacturer Giebel FilTec GmbH Carl-Zeiss-Str. 5 DE-74626 Bretzfeld-Schwabbach Tel. +49 (0)
More informationBOXA-II ON-STREAM X-RAY FLUORESCENCE ANALYZER. Technical Description Version 2 BGRIMM AUTOMATION
BOXA-II ON-STREAM X-RAY FLUORESCENCE ANALYZER Technical Description Version 2 BGRIMM AUTOMATION, South 4th Ring Road West, Beijing, China TEL: +86(10)59069762 Fax: +86(10)68360101 Contents BGRIMM AUTOMATION
More informationSection 2 of 6 Applied Psychrometrics
Section 2 of 6 Applied Psychrometrics Psychrometric chart - your energy map Key psychrometric variables for humidity Predicting building condensation Hot weather Cold weather Predicting moisture sorption
More informationIN-LINE MIXED FLOW EXTRACTOR FANS FOR DUCT MOUNTING. 14 MODELS WITH AND WITHOUT TIMERS. SAFETY AND ACOUSTIC PERFORMANCES CERTIFIED
VORTICE LINEO LONG LIFE.000 h ➀ ➀ ➁ ➁ Lineo series extractors have certified air flow, ressure (to UNI 10531:1995, corresonding to ISO 51) and noise levels (UNI EN ISO 371). Certification of these arameters
More informationflexible couplings for pipe connections
www.arpol.com A R P O L INSTAL flexible couplings for pipe connections 1 TABLE OF CONTENTS Advantages & installation 3 Sealing system & applications Nominal charts Material Specifications Gaps between
More informationThermostatic expansion valves TUA/TUAE
MAKING MODERN LIVING POSSIBLE Technical brochure Thermostatic expansion valves A/AE www.danfoss.com Thermostatic expansion valves, type A/AE Contents Page Introduction... Features... Standard range...
More informationBNA Series. PLENUM FAN with Backward Wheels
BNA Series PLENUM FAN with Backward Wheels BNA Series BNA Series Plenum Fans Backward wheels Kruger Plenum Fans are designed for air handling applications where the fan operates unhoused within a plenum.
More informationANSI/AHRI Standard 1250 (I-P) 2014 Standard for Performance Rating of Walk-in Coolers and Freezers
ANSI/AHRI Standard 1250 (I-P) 2014 Standard for Performance Rating of Walk-in Coolers and Freezers Approved by ANSI on May 19, 2015 - ERRATA SHEET FOR, PERFORMANCE RATING OF WALK-IN COOLERS AND FREEZERS
More information