1 Institutionen för systemteknik Department of Electrical Engineering Examensarbete Load flow control and optimization of Banverket s 132 kv 16 2/3 Hz high voltage grid Examensarbete utfört i Reglerteknik vid Tekniska högskolan i Linköping av Annica Lindén and Anna Ågren LiTH-ISY-EX 05/3727 SE Linköping 2005 Department of Electrical Engineering Linköpings universitet SE Linköping, Sweden Linköpings tekniska högskola Linköpings universitet Linköping

2

3 Load flow control and optimization of Banverket s 132 kv 16 2/3 Hz high voltage grid Examensarbete utfört i Reglerteknik vid Tekniska högskolan i Linköping av Annica Lindén and Anna Ågren LiTH-ISY-EX 05/3727 SE Handledare: Examinator: Markus Gerdin ISY, Linköpigs universitet Thorsten Schütte Rejlers Engineering AB Svante Gunnarsson ISY, Linköpigs universitet Linköping, 20 August, 2005

4

5 Avdelning, Institution Division, Department Division of Automatic Control Department of Electrical Engineering Linköpings universitet S Linköping, Sweden Datum Date Språk Language Svenska/Swedish Engelska/English Rapporttyp Report category Licentiatavhandling Examensarbete C-uppsats D-uppsats Övrig rapport ISBN ISRN LiTH-ISY-EX 05/3727 SE Serietitel och serienummer Title of series, numbering ISSN URL för elektronisk version Titel Title Lastflödesreglering och optimering i Banverkets 132 kv 16 2/3 Hz högspänningsnät Load flow control and optimization of Banverket s 132 kv 16 2/3 Hz high voltage grid Författare Author Annica Lindén and Anna Ågren Sammanfattning Abstract The purpose of this thesis was to investigate the possibility of power flow control, on a section of a railway grid fed by rotary converters, using an extra feeding line. Two possible solutions for the power flow control were examined. The first using a series reactance in connection to each converter station and the second by changing the tap changer level of the transformer between the converter station and the feeding line. In the two models a distance, comparable to the distance between Boden and Häggvik, in Stockholm, was used. The simulations were performed using the software SIMPOW. The results from the performed simulations show that series reactances, under the stated conditions, can essentially improve the power flow. To implement this air coils with inductances in the approximate size of 10 to 45 mh could be used. Further, the tap changer levels of the transformer may be used, for individual converter stations, as a way to control the reactive power flow. Nyckelord Keywords 132 kv, rotary converter, load flow, power flow, feeding line, catenary, tap changer, control system, railway, electrification

6

7 Abstract The purpose of this thesis was to investigate the possibility of power flow control, on a section of a railway grid fed by rotary converters, using an extra feeding line. Two possible solutions for the power flow control were examined. The first using a series reactance in connection to each converter station and the second by changing the tap changer level of the transformer between the converter station and the feeding line. In the two models a distance, comparable to the distance between Boden and Häggvik, in Stockholm, was used. The simulations were performed using the software SIMPOW. The results from the performed simulations show that series reactances, under the stated conditions, can essentially improve the power flow. To implement this air coils with inductances in the approximate size of 10 to 45 mh could be used. Further, the tap changer levels of the transformer may be used, for individual converter stations, as a way to control the reactive power flow. v

8

9 Acknowledgements We would like to thank Thomas Jobenius and Thorsten Schütte, at Rejler s Engineering AB, for the opportunity to do our Master Thesis at the company. All the support and dedication has been invaluable. We also want to give an extra thanks to the employees in Linköping, whom have made us feel very welcome and included. An extra thanks to Banverket and particularly to Sam Berggren, for all the help with material and answers to our questions and to Jonas Persson and Mikael Ström at STRI AB for their fast, good and detailed replies to our endless questions concerning our model and SIMPOW. Finally we would like to thank our professor Svante Gunnarsson and tutor Markus Gerdin at LiTH. vii

10

11 Contents 1 Introduction Background Purpose Electrical traction system History Power supply Rotary converters General Phase shift angle Static converters Cyclo converter PWM converter Loads Problem and possible solutions Problem Possible solutions Solution one - series reactances Solution two - transformer tap changer Solution three - rotary converter, static converter or parametric transformer Solution four - combination Modeling and simulations Restrictions and general simplifications Original models Small model Large model Simulations for the influence of α Solution one - series reactances Additions to the general model in SIMPOW Simulations with variable inductances Model for control system Complementary simulations ix

12 4.5 Solution two - transformer tap changer Additions to the general model in SIMPOW Simulations with different tap changer levels Model for control system Results and conclusions Results using series reactances Results for complementary simulations using series reactances Result using the tap changers on the transformers Conclusions Future work 41 Bibliography 43 A Blondel transformation for power flow 45 A.1 The basic machine parameters A.2 The general power equation A.3 The Blondel transformation A.4 The machine under symmetrical conditions A.4.1 Derivation of voltage and current relations A.4.2 Phasor diagram B The general model of the simulated system 55 B.1 Short description of SIMPOW B.2 The data used in SIMPOW B.3 Figure of the general system B.4 Figure of the system with reactances B.5 Phase difference α during 24-hour period C Air coil 61

13 Chapter 1 Introduction 1.1 Background The Swedish railway system is a low frequency grid fed from the public 50 Hz grid to the railway catenary by rotary and static converters. Rotary converters are synchronous-synchronous machines, which means that the railway system is synchronous with the public 50 Hz grid. This implies that all phase displacement on the public 50 Hz grid, will be transmitted directly to the railway grid. Static converters are constructed so that the phase can be chosen arbitrarily. For efficient load flow separate 132 kv feeding lines, parallel with the railway, are used. The existing 132 kv feeding line supplies only parts of the Swedish railway, since this technique is not efficient in systems with more than one rotary converter, where phase differences appear. Today only static converters can be adjusted to generate voltage with adequate phase. To further optimize the load flow an extension of the 132 kv feeding grid, to include a larger part of the railway system, would be favorable. One option could be to replace all rotary converters with static converters and then extend the 132 kv feeding grid. This is not an economical option, since today approximately half of the generated power comes from rotary converters. 1.2 Purpose The purpose of the thesis is to investigate the possibility of feeding the 132 kv feeding line with several rotary converters. In other words, the goal is to examine the possibility of power flow control, on the 132 kv feeding line, independent of what kind of converters that are used. Some or all of the ideas stated below will be evaluated: 1. Vary the voltage angle using series rectances, inductances or capacitances, between the converter station and transformer. 1

14 2 Introduction 2. Vary the voltage fed to the feeding line by adjusting the circuit coupler of the transformer. 3. Add a 90 degree phase shifted voltage component generated by a smaller rotary or static converter or a parametric transformer. 4. A combination of some or all of the ideas. To compensate for the variation in phase displacement between the rotary converters, a control system is demanded. The ideas are evaluated with the simulation program SIMPOW.

15 Chapter 2 Electrical traction system This chapter gives a short introduction of Swedish railway history and a description of how it works today. 2.1 History The kind of electricity used on the railway grids differ between countries. There exists no given standard for electrical traction systems. Some countries use DCvoltage and other AC-voltage of varying frequency and amplitude, see Figure 2.1. Figure 2.1. Electrical traction in Europe [14] The electrification of the Swedish railway system started in the beginning of the 20th century, using 16 2/3 Hz single phase voltage fed by converters from 3

16 4 Electrical traction system the public 50 Hz grid. The voltage used is 16.5 kv, nominal voltage 15 kv plus 10 %. The only converters available at this time were rotary converters. As the technology progressed static converters became a good alternative to the rotary converters. This contributes to the existence of both rotary and static converters in the railway system. As the load on the Swedish railway increased the need for more efficient power supply grew. The options were to install new converter stations or to build a feeding line parallel to the railway. In the late 1980s a 132 kv feeding line was built from Hallsberg to Jörn [7, 12]. Figure 2.2 shows the Swedish feeding grid in 1997, extended to Boden in the north. Today some further extensions have been made in Mälardalen and in the south of Norrland. All rotary converters in the parts with feeding line, except for the converter station in Häggvik, have been replaced by static converters. Figure 2.2. The extension of the Swedish feeding grid in 1997 [13] 2.2 Power supply The train is supplied with power from the catenary, through a pantograph on the locomotive, as described in Figure 2.3. This power is fed from the three phase public 50 Hz grid through a transformer to a converter station, with either rotary or static converters. These are described below in chapter 2.3 and 2.4. The converted voltage passes through a transformer to the catenary. If a feeding line exists it is fed as well. The voltage on the catenary has a nominal voltage of 15 kv. Normally an extra 10 procent is added which gives a voltage of 16.5 kv.

17 2.2 Power supply 5 Figure 2.3. Description of the power supply [2] The thickness of the catenary and the return conductors is limited by its weight [18]. Further, the catenary also has inductance which leads to the occurance of power drops when the distance between two feeding points is too far. This sets an upper limit for the distance between two converter stations. Figure 2.4. Power transmission with 132 kv feeding line [13]

18 6 Electrical traction system As mentioned in chapter 2.1 a separate 132 kv feeding line, parallel with the catenary, is used for a sufficient load flow. The feeding line is built up by two 66 kv lines in counterphase to one another. Between the converter stations, the power flow is transferred through transformers from the feeding line to the catenary, See Figure 2.4. The catenary receives power directly from the converter stations and indirectly from the feeding line. 2.3 Rotary converters A converter station usually consists of several converter units in parallel. Each converter unit comprises one rotary converter and one step-up transformer to 16.5 kv. In this chapter the principal function of a rotary converter is described General A rotary converter is a synchronous-synchronous machine, which consists of an electrical motor, a generator and a common shaft. The motor is fed by the three phase public 50 Hz grid and the generator generates a single phase voltage, see Figure 2.5. Figure 2.5. The principle of voltage transmission from the 50 Hz grid to the contact line through rotary converters [6]. The rotation speed, n s, of a synchronous motor depends on the frequency of the feeding grid [1], in this case the public 50 Hz grid. The rotation speed, in rounds per minute, is given by n s = 120 f p (2.1)

19 2.3 Rotary converters 7 where f is the frequency of the feeding grid and p is the number of poles of the motor [4]. The rotation speed is unchanged as long as the feeding grid delivers a constant frequency to the motor. A synchronous generator works as a reversed synchronous motor. In a rotary converter the motor and generator are linked together by a shaft. This means that the rotation speed is the same in both parts. For a rotary converter the outgoing frequency is given by n sg = 120 fg p g n sm = 120 fm p m n sg = n sm f g = p g p m f m (2.2) where indexes m and g indicate motor and generator respectively. In Sweden the rotary converters have a motor with 12 poles and a generator with 4 poles [12]. This results in a generated frequency, f g, of a third of the frequency entering the converter. For the rotary converter this means a frequency of 16 2/3 Hz. The magnitude, of the generated voltage, depends on the magnetizing current in the generator and the power flow from the motor [1]. In the Swedish railway grid, three different sizes of rotary converters are used. The small one, Q24, generates 3000 V and the two bigger ones Q38 and Q48 generate 4000 V and 5000 V respectively [5]. Q38 can be seen in Figure 2.6. The nominal power, delivered by the rotary converters, is 2.4 MVA, 4 MVA and 10 MVA respectively [11]. Figure 2.6. A rotary converter of medium size, Q38 [12]. One big advantage with rotary converters is that the load always is symmetric and non oscillating on the 50 Hz grid [16]. Since the synchronous motor of the rotary converter produces adjustable reactive power, it is possible to compensate for voltage drops that occur on the 50 Hz grid. Further, the voltage from the converter station can be held constant by regulating the magnetizing current of the generator. The disadvantage of rotary converters is the long start up time, approximately 2 minutes, and complicated synchronization, see also Chapter

20 8 Electrical traction system Phase shift angle Any phase displacements that occur on the 50 Hz grid will be transmitted to the railway grid by a third, just like the frequency mentioned earlier. Figure 2.7. poles [12] The phasor diagram for a phase in a synchronous machine with salient For a salient pole synchronous machine, the phasor diagram in Figure 2.7 can be drawn [3]. δ, the electrical angle, is defined as the angle between E, the open circuit voltage, and U, the outgoing voltage. X d and X q are the reactances in d- and q-directions. The diagram is drawn per phase, and the d- and q-axes represent the direct- and quadrature-axis respectively in the mathematical Blondel transformation. For an explicit explanation see Appendix A. The following equations can be extracted from Figure 2.7 From Equation 2.3 and 2.4 the electrical angle U sin δ = X q I q (2.3) I q = I cos (δ + ϕ) (2.4) δ = arctan X q I cos ϕ U + X q I sin ϕ (2.5) is given. The active power, P, and reactive power, Q, are defined by P = U I cos ϕ (2.6) Q = U I sin ϕ (2.7) This gives δ = arctan X q P U 2 + X q Q (2.8)

21 2.4 Static converters 9 The angle turning function for the rotary converter is θ var = (δ m + δ g ) (2.9) θ var = 1 3 arctan Xq m P Xq g P (U m ) 2 arctan + Xq m Q 50 (U g ) 2 + Xq g Q (2.10) The total output voltage angle is θ = θ 0 + θ var (2.11) where θ 0 is the no load angle [12]. For converter stations with several parallel rotary converters, it is important to decrease the outgoing voltage from the generator as the reactive power flow increases. This is a way to avoid negative reactive currents and to keep the operation stable [5]. It is important that the output voltage angles, for all converters in the converter station, are approximately the same [12]. To add a feeding line parallel to the catenary, to a part of the railway grid fed by rotary converters, is possible only if the output voltage angles from the different converter stations are almost equal. 2.4 Static converters The technique used in static converters is based on power electronics. There exist two types of static converters, cyclo-converters and PWM-converters [12] Cyclo converter The main component of a cyclo converter is a thyristor bridge. By igniting the thyristors in a suitable order, a one phase low frequency voltage can be created from the three phase public 50 Hz grid. See Figure 2.8 for a principal scheme. To prevent influences on both grids and to increase the generated power a 12-pulse connection, with two thyristor bridges connected in series, is used [5, 16]. One of the bridges is fed from the 50 Hz grid by a Y-connected transformer and the other by a D-connected transformer, see Figure 2.9. A cyclo converter puts high demands on the transformer and creates a lot of reactive power, which must be compensated for PWM converter The intermediate PWM-converter, Pulse Width Modulated converter, converts the voltage in three steps. For a principal scheme of the PWM-converter see Figure The three phase voltage from the public 50 Hz grid is rectified in a 12-pulse rectifier after a step down transformer [5]. In the intermediate DC link the voltage is filtered and in the last step it is modulated in pulses so that the average for the pulses constitutes the one phase voltage.

22 10 Electrical traction system Figure 2.8. Principal scheme of a cyclo converter [12] Figure 2.9. Cyclo converter with 12-pulse connection [16]

23 2.5 Loads 11 Figure Principal scheme of a PWM converter [12] 2.5 Loads In railway systems the loads consist of trains. Their power consumption is complex since it depends on a lot of factors, for example speed, acceleration, weight, track conditions etc. Some common trains in Sweden and Norway are presented in Table 2.1. Locomotive Type Power Weight MW tonne IORE double Ore transport Malmbanan EL16 Conveyance of goods EG3100 Ore transport Malmbanan EL15 Conveyance of goods RC Conveyance of goods X2000 Passenger train Table 2.1. Power consumption in Swedish and Norwegian trains [19]

24 12 Electrical traction system

25 Chapter 3 Problem and possible solutions 3.1 Problem As described in Chapter 1.1, it would be favorable to add a feeding grid parallel to the railway grid. The rotary converters transmit phase differences from the 50 Hz grid to the railway grid according to Chapter In order to connect a feeding grid, the phase in the whole grid needs to be approximately the same. Today, for rotary converters, there exists no method for this kind of compensation. Figure 3.1. The angles for Ū1 and Ū2 The transmitted phase difference, γ, mentioned above, is defined as the angle between the outgoing voltage from two different rotary converter stations, as shown in Figure 3.1. γ = θ 2 θ 1 (3.1) With notation from Figure 3.1 and using complex numbers the two voltages can 13

26 14 Problem and possible solutions be written as Ū 1 = U e jθ1 (3.2) Ū 2 = U e jθ2 = U e j(θ1+γ) (3.3) The apparent power, S, and Ohms law give S = Ū Ī } Ū = Z Ī S = Ū 2 Z (3.4) where Z = Z e jϕ (3.5) is the impedance from the whole system felt by the rotary converter. This leads to the following expressions for S 1 and S 2 S 1 = Ū 2 Z 1 = U 2 Z 1 e j(2θ1 ϕ1) (3.6) S 2 = Ū 2 Z 2 = U 2 Z 2 e j(2θ1+2γ ϕ2) (3.7) If both rotary converters experience the same load from the system, the impedances and the apparent power S can be described as Z 1 = Z 2 = Z (3.8) S 1 = U 2 Z ej(2θ1 ϕ) (3.9) S 2 = U 2 Z ej(2θ1+2γ ϕ) = U 2 Z ej(2θ ϕ) e j2γ (3.10) When the voltages out of the rotary converters are the same and the angle γ is nonzero the active and reactive power from the converter stations will differ, see Figure 3.2. To be able to connect an extra feeding line to the system the effect of γ needs to be eliminated, or at least decreased. In the coming sections some ideas for how this could be done are described.

27 3.2 Possible solutions 15 Figure 3.2. The apparent power S 1 and S Possible solutions In Chapter 1.2 four ideas, that might solve the problem, are presented. These possible solutions are described in this section Solution one - series reactances One possible solution is to use series reactances to compensate for the phase shift γ between the outgoing voltage from the converters. This can not eliminate the problem totally but reduce its influence. The idea is to reduce the effect from γ, described in Chapter 3.1, by connecting an adjustable reactance, X, between the converter station and the transformer to the feeding grid. Theoretically, the reactance used can be either an inductance, L, or a capacitance, C. The difference between using a capacitance or an inductance is that a capacitance has a negative contribution and an inductance a positive. Ū = X Ī (3.11) X L = jωl (3.12) X C = 1 jωc = j 1 ωc (3.13) In phasors this implies, as shown in Figure 3.3, that the voltage is phase shifted with reference to the current. Figure 3.3. The angular influence on the voltage from an inductance and a capacitance

28 16 Problem and possible solutions Returning to the notation in Chapter 3.1 the apparent power S 1 = U 2 Z ej(2θ1 ϕ) (3.14) S 2 = U 2 Z ej(2θ1+2γ ϕ) = U 2 Z ej(2θ1 ϕ) e j2γ (3.15) To compensate for γ a series inductance connected to rotary converter number one may be used. The first rotary converter will now experience another load from the system which implies and the apparent power generated is Z nl = Z + X L = Z nl e j(ϕ+ ϕ) (3.16) Ū 1n = Ū1 e j ϕ = Ū ej(θ1+ ϕ) (3.17) S 1n = U 2 Z nl e j(2θ1 ϕ) e j ϕ (3.18) S 2 = U 2 2 Z ej(2θ1 ϕ) e j2γ (3.19) The difference in angle for the apparent power from rotary converter one and two, and the magnitude of S 1 have decreased. Both things lead to a decreased influence from γ on the system, see Figure 3.4. Figure 3.4. The apparent power under influence of an inductance connected to rotary converter number one. Instead of an inductance a series capacitance connected to rotary converter number two may be used. Now rotary converter number two experiences another load from the system. which implies Z nc = Z + X C = Z nc e j(ϕ ϕ) (3.20) Ū 2n = Ū2 e j ϕ = Ū ej(θ1 ϕ) (3.21)

29 3.2 Possible solutions 17 and the apparent power generated is S 1 = U 2 Z ej(2θ1 ϕ) (3.22) S 2n = U 2 e j(2θ1 ϕ) e j(2γ ϕ) Z nc (3.23) This can decrease the angular difference between the voltages as much as using Figure 3.5. The apparent power under influence of a capacitance connected to rotary converter number two. an inductance would do. Just as before, the magnitude of the apparent power is decreased. The first part contributes to a decrease of the influence from γ, but the second part does not. See Figure 3.5. This leads to the conclusion that it might be better to use inductances for compensation than capacitances Solution two - transformer tap changer The second idea is to vary the voltage fed to the feeding line by adjusting the tap changer of the transformer. If the voltage fed to the feeding line increases the power flow will also increase and vice versa. The transformers used in Sweden have five different levels, 0, ±2.5, ±5 percent, to chose between. The level used today is zero. Just like the solution described in Chapter this solution will not give a perfect result, but the difference in power can be decreased. Returning to the notation in Chapter 3.1 the angular difference γ between Ū1 and Ū2 contributes to a difference in active and reactive power, P and Q. The active power out of converter one is greater than the active power out of converter two, and the other way around for the reactive power. When adjusting the tap changer to decrease the difference in active power, the difference in reactive power will rise. The adjustments made to minimize the difference in P can be accomplished in two ways. The solution would either be to rise the tap changer to a higher level for transformer number two or to lower the tap changer for transformer number one. As illustrated in Figure 3.6 and as mentioned earlier this leads to an increase in the difference in reactive power Q. The change in transformer number one leads to a smaller increase in Q than a change in number two does.

30 18 Problem and possible solutions Figure 3.6. Comparision of the changes in apparent power, at the left when the tap changer is lifted one level at transformer two and and at the right when the tap changer is lowered one level at transformer one Solution three - rotary converter, static converter or parametric transformer The third possible solution, as mentioned earlier in Chapter 1.2, is to add a 90 degree phase shifted voltage component generated by a smaller rotary or static converter or a parametric transformer. This is another way to shift the phase for the voltage. Using the same notation as in Chapter 3.1, and connecting a smaller rotary converter in series with rotary converter number one, the voltage component can be described as and the new voltage will be as illustrated in figure 3.7. Ū comp = U comp e j(θ1+ π 2 ) (3.24) Ū 1n = U comp e j(θ1+ π 2 ) + U e jθ1 = U 1n e j(θ1+ θ1) (3.25) Figure 3.7. The changes in Ū1 using a rotary converter to compensate for γ. Since this phase shift is a total phase shift, i.e. both the voltage and the current are shifted in the same manner, the angle ϕ will be preserved. The apparent power

31 3.2 Possible solutions 19 can be described as S 1n = U 1n 2 Z ej(2θ1 ϕ) e j2 θ1 (3.26) S 2 = U 2 e j(2θ1 ϕ) e j2γ Z nc (3.27) If U comp is chosen wisely a total compensation for the difference in phase, γ, between U 1 and U 2 can be achieved. This occurs when θ 1 = γ (3.28) Even though the phase displacement is gone, there still exists a difference in power. As seen to the left in Figure 3.8 the apparent power, S n1, is bigger in magnitude than S 2. By using the technique described in Chapter the problem can be eliminated. As shown to the right in Figure 3.8 the compensation for γ might as Figure 3.8. The apparent power when using a rotary converter for compensation of γ well be done by connecting a smaller rotary converter to converter number two. This works the same way as stated above with the exception for the phase shift in Ū comp, which will switch sign and be negative Solution four - combination The fourth possible solution is to combine one or several of the described solutions above. From an economical aspect the best solution could be to combine serie inductances with a good level for the tap changers of the transformers.

32 20 Problem and possible solutions

33 Chapter 4 Modeling and simulations In this chapter the used models and simulations are described. The modeling and simulation are based on idea one and two from chapter 3. The third idea was not investigated as the work grew in size with the modeling of the first idea. For implementation and simulations the program SIMPOW, see Appendix B.1, was used. 4.1 Restrictions and general simplifications The Swedish railway grid is a very complex system with a lot of factors to account for. Already when studying a smaller part of the system it shows large complexity. The purpose of this thesis is to study the influences of α, the phase difference between the voltages fed to the converter stations on the public 50 Hz grid, on a railway grid fed by rotary converters and evaluate the possibility of power flow control. To create the model some simplifications and restrictions were made. 1. The system is symmetric and this means that the distances between all converter stations and transformers are equal throughout the whole model. 2. All converter stations use only one type of rotary converters, the Q48s. Further, the rotary converters in the stations are represented by one rotary converter with three times as big power as one Q48, instead of three Q48s in parallel with each other. 3. The trains are looked upon as a constant load and are placed symmetrically. Their movements are considered as disturbances, i.e. on average the load is constant. This simplification can be made since the power flow studied is the one depending on the angular difference α. 4. The change in angular difference α has a large time constant, and it does not occur instantaneously. 5. The 50 Hz net is modeled as a number of strong constant voltage sources with a specified phase angle for each feeding point. 21

34 22 Modeling and simulations A detailed description of the model can be found in Chapter Original models During the work with the thesis two different models have been used. A small prototype model for initial tests and a large one for the simulations Small model The purpose of the small model was to understand the power flow and to learn the simulation program SIMPOW. The small model consists of two rotary converters, one train, feeding line, catenary and three transformers. The distance between the two converter stations in the model was 100 km and a transformer, called T 3 as showed in Figure 4.1, was placed half-way. The first calculations of the power flow were made in MATLAB, using very simple models of transformers and converter stations. The next step was to use SIMPOW which provides more sophisticated models for the components. The small model made it easier to identify how the different components in SIMPOW work. Figure 4.1. The small model Large model The large system can be seen as a simplified model of the railway between Boden and Häggvik in Stockholm. The total length of the track is chosen to 1000 km and there are six converter stations symmetrically distributed, with one converter station at each end point. The converter stations consisting of three Q48s with one transformer each are modeled as one rotary converter and one transformer, marked T 1 in Appendix B.3. Each converter station produces at maximum 30 MVA in apparent power. There are two kinds of transformers used to connect the catenary and the feeding line, marked T 2 and T 3. They differ in nominal

35 4.2 Original models 23 power, 25 MVA in apparent power for T 2 and only 16 MVA for T 3 [9]. The transformers are placed symmetrically with a distance of 50 km in between. A total number of 27 transformers are used. To model an even load from the trains 20 RC-trains, using maximal power, are placed symmetrically half-way between every transformer along the catenary. The train s movements along the catenary are looked upon as negligible disturbances, as mentioned in Chapter 4.1. The phase difference, α, on the three phase public 50 Hz grid, was modeled as α degrees at rotary converter one with a linear change down to zero degrees phase difference at rotary converter number six. All data used for the model can be found in Appendix B. Figure 4.2. The power flow, out of rotary converter station number one through six, with no phase difference transferred from the public 50 Hz grid. Models in SIMPOW are built up by nodes. To simplify the notation, in the following sections, the nodes connecting the rotary converter stations and the transformers, T 2, are marked Inlow 1 through Inlow 6, see Appendix B.3. Since the model is symmetric and consists of a finite number of rotary converter stations, the ones in the middle experience more load than those at each end. These edge effects lead to a smaller generation of power in the outer converter stations. Figure 4.2 shows the active, reactive and apparent power in Inlow 1 through Inlow 6 for this case.

36 24 Modeling and simulations 4.3 Simulations for the influence of α When adding a phase difference α, on the 50 Hz side, a phase difference γ = α 3 is transferred to the railway grid, as described in Chapter According to Chapter 3.1 a rotary converter which lags in phase compared to another converter produces more active power. In order to find an approximation for how the changes in power production depend on the phase difference α several simulations were made. The active power flow vector P 1 P 2 P =. P 6 shows the active power flow in Inlow 1 through Inlow 6, see Appendix B.3, were studied for α = 0, 15, 30 and 45 degrees. The results for P 4, P 5 and P 6 can be viewed in Figure 4.3. P 1, P 2 and P 3 show the same tendencies but with a decrease in active power with an increased α. From the simulations a linear approximation for how the active power depends on α was estimated. P (α) = Kα + P 0 (4.1) where K is the vector containing the gradients and P 0 is the power flow vector when α is zero. Figure 4.3. The influence of α on the power flows P 4, P 5 and P 6

37 4.4 Solution one - series reactances Solution one - series reactances Additions to the general model in SIMPOW The first possible solution investigated was the use of series reactances to compensate for the induced phase differences. The idea is chosen for its simplicity and because it is probably the most economical solution. The possible solution would be, as described in Chapter 3.2.1, to place a variable reactance between the converter station and the transformer feeding the feeding line. To do this the large model in Chapter was modified. One extra node, placed between the outgoing node at the converter station and the transformer to the feeding line, was inserted for each converter station. These new nodes are called Contr 1 through Contr 6, see Appendix B.4. With no reactance used the two nodes, Inlow i and Contr i were short circuited by an ideal line. The railway system is of inductive nature, so from that point of view it would be favorable to use capacitances. According to Chapter and because they are easier to construct of suitable size the reactances used were inductive. From now on the notation X = X L (4.2) will be used and the reactance connected between Inlow i and Contr i will be referred to as X i Simulations with variable inductances The possibility to change the power flow using reactances was obvious after a few simulations with different values of X i. The next step was to find an expression for the estimated active power which included X i. In Chapter 4.3 the linear dependence of α for the active power vector P is described. To expand equation 4.1 to include the dependence of the reactances x, where x = X 1. X 6 (4.3) the assumption was made that P depends independently on x and α without correlation. P ( x, α) = P 0 + K (α) + M ( x) (4.4) To study the dependence simulations were made with all reactances equal, X i = 0, 1, 2 and 3. The active power flow was studied for the same α as in section 4.3, α = 0, 15, 30 and 45 degrees phase shift. To define how a change in reactance X i affects the power flow in all measured points further simulations were made. In these simulations one reactance at the time were changed, in steps of 0.5 Ω, and the other were held constant. This to define how a change in for example

38 26 Modeling and simulations X 1 affects the power flow P 3. The test runs showed that the dependence was non-linear, of the natural logarithm type, so the assumption M ( x) = A ln ( x + 1) (4.5) was made. It is important to note that the assumption ln ( x + 1) is possible to make in this case, due to the approximate size of the reactances. If the reactances had been of another approximate size the vector would have had to be normalized with a reference reactance, x ref. In this case it can be looked upon as if x ref = 1Ω. The one in Equation 4.5 represents a vector of ones of appropriate size. A is a square matrix with positive elements except for the diagonal elements which represents the influence of X i on P i. This assumption was based on the fact that the reactances are of the inductive kind and that it should be possible to set a reactance to zero, i.e. disconnect it. In order to determine the elements in matrix A the cross influences were assumed to be additive. a 11 a 12 a 16. M ( x) = a ln a 61 a 66 X X X (4.6) where a ij represents the influence from X j on P i. By using the assumption in Equation 4.4 with M( x) as in Equation 4.6 and studying the simulations performed in SIMPOW the elements in K and in Ā were estimated. When comparing the estimated P i values to the simulated values for P i a satisfactory result was achieved as long as the reactances used were approximately the same. This is illustrated in Figure 4.4. In Inlow 3 through Inlow 6 a small deviation can be seen, but it is small enough to disregard. Figure 4.4. The simulated and estimated values of the active power in Inlow 1 through Inlow 6 when all reactances X i = 2 Ω and α = 30 degrees. The values of X i needed to compensate for α differ between the converter stations, thus it is essential that the estimate is good for these values as well. Figure

39 4.4 Solution one - series reactances shows the estimated and simulated values for P i when α is 30 degrees and appropriate x. The estimated and simulated values for P 5 and P 6 differ too much. Further investigations gave that matrix A depends on both x and α. This gives Figure 4.5. The simulated and estimated values for the active power in Inlow 1 through Inlow 6 when α = 30 degree and the reactances chosen as in simulation number 23. the following expression for M ( x, α) M ( x, α) = A( x, α) ln ( x + 1) (4.7) First the dependence of α was examined and a small variation could be detected. The estimated values for P i, using A(α), were compared to the earlier estimations for P i. The differences were so small that it is possible to overlook the influence of α on A. The problem is the dependence of x. In the previous model of P the influences of X i are assumed to be additive, which apparently is incorrect. A lot of different approximations have been made, where, for example, the influences from the nearest converter stations are taken into account and other where the mean reactance felt by the system has been used in different compositions. No one of the assumed approximations of P have given a good enough agreement with the simulated values from SIMPOW. The estimated model for the active power generates a good approximation only when the elements of X are close in size. Since the values of x, for a good compensation of α varies, the decision was made not to do any further attempts to estimate a model for the active power flow. The approach now was to find optimal values for x for each α= 0, 15, 30 and 45 degrees. To find the appropriate values of X i the knowledge gained during the estimation process of P was used. The goal was to minimize the differences in Pi with acceptable differences in reactive power, Q i, for the converter stations. As help in this selection Figure 4.6 was used. This figure shows the maximal difference in active and reactive power for a number of simulations, when α = 45 degrees. From simulation number 22 and up, all the simulations have an acceptable value for the difference in active power. The reactive power has a large variation between different simulations. The choice of x is a balance between the differences in P i and

40 28 Modeling and simulations Figure 4.6. The maximal difference in P and Q for a number of simulations, that was used as a guideline to determine a suitable choice of x when α = 45 degrees. Q i, however the size of the reactances need to be taken into account. Simulations number 23 and 28 have almost the same values for the maximal difference in Q i. Even though simulation number 28 has a smaller difference in P i, the reactances used in simulation number 23 were significantly smaller and therefore the values of x for simulation number 23 were chosen Model for control system The idea was to use a feedback control system, but as mentioned in Chapter the approximated active power flows were not good enough for this purpose. The choice then was to use a feed forward control system, that uses the phase difference α as input signal and four possible levels for the reactances as output. Another choice could be to set the reactances for a phase difference α = 30 degrees and be satisfied with this simple solution. A more detailed discussion is presented in Chapter Complementary simulations A few complementary simulations were made for some special cases. These cases were simulated to see which deviation would occure if some basic conditions were changed. This was done in order to get an indication of how robust the solution is. In the first case rotary converter one through three have 30 degrees lag on the 50 Hz public grid and rotary converter four through six has a linear change, in steps of 10 degrees, down to zero. In the second case the load from the trains were halved. A discussion of the result is presented in Chapter 5.

41 4.5 Solution two - transformer tap changer Solution two - transformer tap changer Additions to the general model in SIMPOW To do test runs, for the idea described in Chapter 3.2.2, the original large system was used. The tap changer on the transformer has five different levels, which are 0, ±2.5, ±5%. The transformers used in SIMPOW has no tap changing function so to simulate this the transformers outgoing voltages were changed in steps shown in Table 4.1. Change in Outgoing % voltage in kv Table 4.1. Tap changer levels with corresponding outgoing voltage The tap changer level is referred to, in the same way as for the reactances in Chapter 4.4.2, as a vector, V 1 V 2 V = (4.8). V 6 where V i can have the values shown in Table 4.1 in Volt Simulations with different tap changer levels According to the conclusions in Chapter no attempt was made to estimate a state space model for the large model. Instead an ad hoc approach for this idea was used. Simulations were made for phase differences of α= 0, 15, 30 and 45 degrees. As mentioned in Chapter 3.2.2, it would be favorable to change the tap changer on the transformer that is in lag. This implies that a first approach should be to lower the tap changer connected to Inlow1. If this is not enough the next transformer that would be changed is the one at Inlow2. The decision strategy was based on minimizing the maximal difference in P i and then minimize the maximal difference in the reactive power, Q i, as in Chapter As seen in Figure 4.7, these two differences vary a lot. To learn how the system responded to different choices of V a large number of simulations were made. Figure 4.8 shows how the power flow changes when V 3 is lowered one level, from 2.5 to 5. As seen in the figure the effect on the reactive power is stronger than on the active power. To change the tap changer one level generates a large difference in the power flow.

42 30 Modeling and simulations Figure 4.7. The maximal difference in P and Q for a number of simulations, that was used as a guideline to determine a suitable choice of V when α = 45 degrees. Figure 4.8. The active, reactive and apparent power when tap changer 3 is changed from 2.5% to 5%.

43 4.5 Solution two - transformer tap changer Model for control system According to section it is not possible to use a feed back system, so the choice would be either a feed forward system or a static setting for the tap changer. A more detailed discussion is presented in Chapter 5.

44 32 Modeling and simulations

45 Chapter 5 Results and conclusions This chapter presents the results obtained with the methods described in Chapter 4, discussions concerning the results and the conclusions. 5.1 Results using series reactances Under the conditions stated in Chapter 4, the simulations performed with the large model show some positive results. It can be seen that under these conditions the power flow can be controlled. For each angular difference α = 0, 15, 30 and 45 degrees, according to Chapter 4.2.2, a specific combination of reactances x, that contributes to an obvious improvement of the power flow, was found. In Figures 5.1 and 5.2 the power flow in Inlow 1 through Inlow 6, when α is 30 degrees and when α is 45 degrees, are shown. To illustrate the improvements in the power flow, both the power flow for a suitable choice of reactances and the power flow without compensation for α are included. As seen in the Figures 5.1 and 5.2, a large improvement can be detected in both the active power, P, reactive power, Q and the apparent power, S. As desired the difference in the power production, between the converter stations, has decreased. The reactances used in these cases are, as stated in Chapter 4.4.1, of the inductive kind. The size of the inductances varies between 10 mh and 45 mh. In Appendix C an approximate dimensioning for a 10 mh air coil is included. When studying the simulations the conclusion were drawn that it would not be necessary to have a continuous compensation for changes in α. As mentioned in Chapter one alternative could be to do the same compensation for an interval of α, for example all α between 7 and 22 degrees would be controlled with the same set of inductances. This would give four intervals for α. 33

46 34 Results and conclusions Figure 5.1. The active, reactive and apparent power, with and without series reactances, in Inlow 1 through Inlow 6 with α = 30 degrees. Figure 5.2. The active, reactive and apparent power, with and without series reactances, in Inlow 1 through Inlow 6 with α = 45 degrees.

47 5.1 Results using series reactances 35 Since there are four intervals for α the principal arrangement for the series inductances would be four different levels for each converter station. For converter station number one this would mean a series connection like the one in Figure 5.3. For small α, where no compensation is needed in converter station number one, both circuit breaker B 1 and B 2 would be closed. Depending on what interval α is in, one or both of the circuit breakers can be opened. This means that four different levels of compensation can be achieved. In some of the cases it might be necessary to have more than two inductances in series. An alternative solution Figure 5.3. An example of circuit connection using series inductances at rotary converter number one. would be, as mentioned in Chapter 4.4.3, to use the same reactances regardless of α. In this solution an average compensation regarding to the fluctuation of α during a 12-hour or 24-hour period could be chosen. As seen in Appendix B.5, α has small fluctuations during long periods of time and then makes a large change, at the beginning and end of the day. According to this it could be possible to use an adjustment with, for example, α = 30 degrees during the whole day and get a good enough improvement. The simulations made for α = 15 and 45 degrees with the suitable choice of reactances for α = 30 degrees, x 30, can be studied in Figure 5.4 and 5.5. As expected the compensation is not as good as when the specific reactances for each α are used, also included in Figure 5.4 and 5.5, but it is still clearly an improvement compared to no compensation at all, see Figure 5.1 and 5.2.

48 36 Results and conclusions Figure 5.4. The active, reactive and apparent power flow when α = 15 degrees and reactances for α = 15 and 30 degrees respectively are used. Figure 5.5. The active, reactive and apparent power flow when α = 45 degrees and reactances for α = 45 and 30 degrees respectively are used.

49 5.2 Results for complementary simulations using series reactances Results for complementary simulations using series reactances The complementary simulations mentioned in Chapter show that the system is rather robust, when exposed to small changes. Changing α in the large model, according to Chapter 4.4.4, changes the power flow in Inlow 1 through Inlow 6. Simulating the angular difference, on the 50 Hz grid, as 30 degrees for the three first converter stations and then as a linear decrease down to zero at converter station number six and without any compensation will contribute to a power flow according to Figure 5.6. The second set of values in the figure is the power flow when the same reactances are used as for α = 30 degrees in Chapter 5.1. Even though these reactances are not the optimal choice for compensation an improvement is detected when the two power flows in Figure 5.6 are compared. Figure 5.6. The active, reactive and apparent power flow in Inlow 1 through Inlow 6, with and without compensation, when the angular difference is unevenly distributed. In the next set of simulations the large model, described in Chapter 4.2.2, was changed by halving the loads from each train, as described in Chapter In Figure 5.7 the power flow with and without compensating reactances are shown. The angular difference α = 30 degrees and the reactances used are the same as for α = 30 degrees in Chapter 5.1. As seen in Figure 5.7 the used reactances do not give a perfect compensation, but using reactances suitable for a load twice the size still give a good improvement in power flow. These two cases give indications that the system is robust and for small changes the same compensation can be used.

Linköping University Electronic Press

Linköping University Electronic Press Linköping University Electronic Press Report Simulation Model of a 2 Degrees of Freedom Industrial Manipulator Patrik Axelsson Series: LiTH-ISY-R, ISSN 400-3902, No. 3020 ISRN: LiTH-ISY-R-3020 Available

More information

Block diagonalization of matrix-valued sum-of-squares programs

Block diagonalization of matrix-valued sum-of-squares programs Block diagonalization of matrix-valued sum-of-squares programs Johan Löfberg Division of Automatic Control Department of Electrical Engineering Linköpings universitet, SE-581 83 Linköping, Sweden WWW:

More information

System analysis of a diesel engine with VGT and EGR

System analysis of a diesel engine with VGT and EGR System analysis of a diesel engine with VGT and EGR Master s thesis performed in Vehicular Systems by Thomas Johansson Reg nr: LiTH-ISY-EX- -5/3714- -SE 9th October 25 System analysis of a diesel engine

More information

An efficient implementation of gradient and Hessian calculations of the coefficients of the characteristic polynomial of I XY

An efficient implementation of gradient and Hessian calculations of the coefficients of the characteristic polynomial of I XY Technical report from Automatic Control at Linköpings universitet An efficient implementation of gradient and Hessian calculations of the coefficients of the characteristic polynomial of I XY Daniel Ankelhed

More information

Power System Analysis Prof. A. K. Sinha Department of Electrical Engineering Indian Institute of Technology, Kharagpur

Power System Analysis Prof. A. K. Sinha Department of Electrical Engineering Indian Institute of Technology, Kharagpur Power System Analysis Prof. A. K. Sinha Department of Electrical Engineering Indian Institute of Technology, Kharagpur Lecture - 9 Transmission Line Steady State Operation Welcome to lesson 9, in Power

More information

Properties and approximations of some matrix variate probability density functions

Properties and approximations of some matrix variate probability density functions Technical report from Automatic Control at Linköpings universitet Properties and approximations of some matrix variate probability density functions Karl Granström, Umut Orguner Division of Automatic Control

More information

Chapter 3 AUTOMATIC VOLTAGE CONTROL

Chapter 3 AUTOMATIC VOLTAGE CONTROL Chapter 3 AUTOMATIC VOLTAGE CONTROL . INTRODUCTION TO EXCITATION SYSTEM The basic function of an excitation system is to provide direct current to the field winding of the synchronous generator. The excitation

More information

Robust Control Of A Flexible Manipulator Arm: A Benchmark Problem

Robust Control Of A Flexible Manipulator Arm: A Benchmark Problem Robust Control Of A Flexible Manipulator Arm: A Benchmark Problem Stig Moberg, Jonas Öhr Division of Automatic Control Department of Electrical Engineering Linköpings universitet, SE-581 83 Linköping,

More information

1 Unified Power Flow Controller (UPFC)

1 Unified Power Flow Controller (UPFC) Power flow control with UPFC Rusejla Sadikovic Internal report 1 Unified Power Flow Controller (UPFC) The UPFC can provide simultaneous control of all basic power system parameters ( transmission voltage,

More information

Institutionen för systemteknik

Institutionen för systemteknik Institutionen för systemteknik Department of Electrical Engineering Examensarbete Multiple Platform Bias Error Estimation Examensarbete utfört i Reglerteknik vid Tekniska högskolan i Linköping av Åsa Wiklund

More information

BASIC PRINCIPLES. Power In Single-Phase AC Circuit

BASIC PRINCIPLES. Power In Single-Phase AC Circuit BASIC PRINCIPLES Power In Single-Phase AC Circuit Let instantaneous voltage be v(t)=v m cos(ωt+θ v ) Let instantaneous current be i(t)=i m cos(ωt+θ i ) The instantaneous p(t) delivered to the load is p(t)=v(t)i(t)=v

More information

Institutionen för systemteknik

Institutionen för systemteknik Institutionen för systemteknik Department of Electrical Engineering Examensarbete Estimation of Inter-cell Interference in 3G Communication Systems Examensarbete utfört i Reglerteknik vid Tekniska högskolan

More information

THREE-PHASE CIRCUITS

THREE-PHASE CIRCUITS THR-HAS CIRCUITS 4.1 Introduction Generation, Transmission and distribution of electricity via the National Grid system is accomplished by three-phase alternating currents. The voltage induced by a single

More information

KINGS COLLEGE OF ENGINEERING Punalkulam

KINGS COLLEGE OF ENGINEERING Punalkulam KINGS COLLEGE OF ENGINEERING Punalkulam 613 303 DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING POWER SYSTEM ANALYSIS QUESTION BANK UNIT I THE POWER SYSTEM AN OVERVIEW AND MODELLING PART A (TWO MARK

More information

Institutionen för systemteknik

Institutionen för systemteknik Institutionen för systemteknik Department of Electrical Engineering Examensarbete Modeling and Identification of the Gantry-Tau Parallel Kinematic Machine Examensarbete utfört i Reglerteknik vid Tekniska

More information

EE Branch GATE Paper 2010

EE Branch GATE Paper 2010 Q.1 Q.25 carry one mark each 1. The value of the quantity P, where, is equal to 0 1 e 1/e 2. Divergence of the three-dimensional radial vector field is 3 1/r 3. The period of the signal x(t) = 8 is 0.4

More information

POWER SEMICONDUCTOR BASED ELECTRIC DRIVES

POWER SEMICONDUCTOR BASED ELECTRIC DRIVES POWER SEMICONDUCT BASED ELECTRIC DRIVES [Time: 3 Hrs] [Max. Marks: 80] Instructions: Solve any six questions from Q.No (1 or 2), Q.No (3 or 4), Q.No (5 or 6), Q.No (7 or 8), Q.No (9 or 10), Q.No (11 or

More information

Department of Physics, Chemistry and Biology

Department of Physics, Chemistry and Biology Department of Physics, Chemistry and Biology Master s Thesis Quantum Chaos On A Curved Surface John Wärnå LiTH-IFM-A-EX-8/7-SE Department of Physics, Chemistry and Biology Linköpings universitet, SE-58

More information

LTI Approximations of Slightly Nonlinear Systems: Some Intriguing Examples

LTI Approximations of Slightly Nonlinear Systems: Some Intriguing Examples LTI Approximations of Slightly Nonlinear Systems: Some Intriguing Examples Martin Enqvist, Lennart Ljung Division of Automatic Control Department of Electrical Engineering Linköpings universitet, SE-581

More information

7. Transient stability

7. Transient stability 1 7. Transient stability In AC power system, each generator is to keep phase relationship according to the relevant power flow, i.e. for a certain reactance X, the both terminal voltages V1and V2, and

More information

Basics of Electric Circuits

Basics of Electric Circuits António Dente Célia de Jesus February 2014 1 Alternating Current Circuits 1.1 Using Phasors There are practical and economic reasons justifying that electrical generators produce emf with alternating and

More information

Institutionen för systemteknik

Institutionen för systemteknik Institutionen för systemteknik Department of Electrical Engineering Examensarbete Development and Analysis of Synchronization Process Control Algorithms in a Dual Clutch Transmission Examensarbete utfört

More information

Module 4. Single-phase AC Circuits

Module 4. Single-phase AC Circuits Module 4 Single-phase AC Circuits Lesson 14 Solution of Current in R-L-C Series Circuits In the last lesson, two points were described: 1. How to represent a sinusoidal (ac) quantity, i.e. voltage/current

More information

Dynamics of the synchronous machine

Dynamics of the synchronous machine ELEC0047 - Power system dynamics, control and stability Dynamics of the synchronous machine Thierry Van Cutsem t.vancutsem@ulg.ac.be www.montefiore.ulg.ac.be/~vct October 2018 1 / 38 Time constants and

More information

ECE 585 Power System Stability

ECE 585 Power System Stability Homework 1, Due on January 29 ECE 585 Power System Stability Consider the power system below. The network frequency is 60 Hz. At the pre-fault steady state (a) the power generated by the machine is 400

More information

Three Phase Circuits

Three Phase Circuits Amin Electronics and Electrical Communications Engineering Department (EECE) Cairo University elc.n102.eng@gmail.com http://scholar.cu.edu.eg/refky/ OUTLINE Previously on ELCN102 Three Phase Circuits Balanced

More information

Institutionen för systemteknik

Institutionen för systemteknik Institutionen för systemteknik Department of Electrical Engineering Examensarbete Modelling a piezoelectric-driven actuator for active flow control Examensarbete utfört i Reglerteknik vid Tekniska högskolan

More information

Non-linear Dynamic Inversion

Non-linear Dynamic Inversion Control of Unmanned Aerial Vehicles using Non-linear Dynamic Inversion Master s Thesis Division of Automatic Control Department of Electrical Engineering Linköping University Mia Karlsson LiTH-ISY-EX-3-

More information

Introduction to Synchronous. Machines. Kevin Gaughan

Introduction to Synchronous. Machines. Kevin Gaughan Introduction to Synchronous Machines Kevin Gaughan The Synchronous Machine An AC machine (generator or motor) with a stator winding (usually 3 phase) generating a rotating magnetic field and a rotor carrying

More information

B.E. / B.Tech. Degree Examination, April / May 2010 Sixth Semester. Electrical and Electronics Engineering. EE 1352 Power System Analysis

B.E. / B.Tech. Degree Examination, April / May 2010 Sixth Semester. Electrical and Electronics Engineering. EE 1352 Power System Analysis B.E. / B.Tech. Degree Examination, April / May 2010 Sixth Semester Electrical and Electronics Engineering EE 1352 Power System Analysis (Regulation 2008) Time: Three hours Answer all questions Part A (10

More information

ECEN 460 Exam 1 Fall 2018

ECEN 460 Exam 1 Fall 2018 ECEN 460 Exam 1 Fall 2018 Name: KEY UIN: Section: Score: Part 1 / 40 Part 2 / 0 Part / 0 Total / 100 This exam is 75 minutes, closed-book, closed-notes. A standard calculator and one 8.5 x11 note sheet

More information

Sinusoidal Steady-State Analysis

Sinusoidal Steady-State Analysis Chapter 4 Sinusoidal Steady-State Analysis In this unit, we consider circuits in which the sources are sinusoidal in nature. The review section of this unit covers most of section 9.1 9.9 of the text.

More information

Institutionen för systemteknik

Institutionen för systemteknik Institutionen för systemteknik Department of Electrical Engineering Examensarbete Sensor-less Control of a Permanent Magnet Synchronous Motor Examensarbete utfört i Reglerteknik vid Tekniska högskolan

More information

ELECTROMAGNETIC OSCILLATIONS AND ALTERNATING CURRENT

ELECTROMAGNETIC OSCILLATIONS AND ALTERNATING CURRENT Chapter 31: ELECTROMAGNETIC OSCILLATIONS AND ALTERNATING CURRENT 1 A charged capacitor and an inductor are connected in series At time t = 0 the current is zero, but the capacitor is charged If T is the

More information

QUESTION BANK ENGINEERS ACADEMY. Power Systems Power System Stability 1

QUESTION BANK ENGINEERS ACADEMY. Power Systems Power System Stability 1 ower ystems ower ystem tability QUETION BANK. A cylindrical rotor generator delivers 0.5 pu power in the steady-state to an infinite bus through a transmission line of reactance 0.5 pu. The generator no-load

More information

GATE 2010 Electrical Engineering

GATE 2010 Electrical Engineering GATE 2010 Electrical Engineering Q.1 Q.25 carry one mark each 1. The value of the quantity P, where P = xe dx, is equal to (A) 0 (B) 1 (C) e (D) 1/e 2. Divergence of the three-dimensional radial vector

More information

Institutionen för systemteknik

Institutionen för systemteknik main: 2005-9-5 9:41 1(1) Institutionen för systemteknik Department of Electrical Engineering Examensarbete A Tracking and Collision Warning System for Maritime Applications Examensarbete utfört i Reglerteknik

More information

Proceedings of the 13th WSEAS International Conference on CIRCUITS

Proceedings of the 13th WSEAS International Conference on CIRCUITS About some FACTS devices from the power systems MARICEL ADAM, ADRIAN BARABOI, CATALIN PANCU Power Systems Department, Faculty of Electrical Engineering Gh. Asachi Technical University 51-53, D. Mangeron,

More information

SSC-JE EE POWER SYSTEMS: GENERATION, TRANSMISSION & DISTRIBUTION SSC-JE STAFF SELECTION COMMISSION ELECTRICAL ENGINEERING STUDY MATERIAL

SSC-JE EE POWER SYSTEMS: GENERATION, TRANSMISSION & DISTRIBUTION SSC-JE STAFF SELECTION COMMISSION ELECTRICAL ENGINEERING STUDY MATERIAL 1 SSC-JE STAFF SELECTION COMMISSION ELECTRICAL ENGINEERING STUDY MATERIAL Power Systems: Generation, Transmission and Distribution Power Systems: Generation, Transmission and Distribution Power Systems:

More information

ELEC Introduction to power and energy systems. The per unit system. Thierry Van Cutsem

ELEC Introduction to power and energy systems. The per unit system. Thierry Van Cutsem ELEC0014 - Introduction to power and energy systems The per unit system Thierry Van Cutsem t.vancutsem@ulg.ac.be www.montefiore.ulg.ac.be/~vct October 2018 1 / 12 Principle The per unit system Principle

More information

ECE 325 Electric Energy System Components 7- Synchronous Machines. Instructor: Kai Sun Fall 2015

ECE 325 Electric Energy System Components 7- Synchronous Machines. Instructor: Kai Sun Fall 2015 ECE 325 Electric Energy System Components 7- Synchronous Machines Instructor: Kai Sun Fall 2015 1 Content (Materials are from Chapters 16-17) Synchronous Generators Synchronous Motors 2 Synchronous Generators

More information

Synchronous Machines

Synchronous Machines Synchronous Machines Synchronous Machines n 1 Φ f n 1 Φ f I f I f I f damper (run-up) winding Stator: similar to induction (asynchronous) machine ( 3 phase windings that forms a rotational circular magnetic

More information

Lane departure detection for improved road geometry estimation

Lane departure detection for improved road geometry estimation Lane departure detection for improved road geometry estimation Thomas B. Schön, Andreas Eidehall, Fredrik Gustafsson Division of Automatic Control Department of Electrical Engineering Linköpings universitet,

More information

Simulations and Control of Direct Driven Permanent Magnet Synchronous Generator

Simulations and Control of Direct Driven Permanent Magnet Synchronous Generator Simulations and Control of Direct Driven Permanent Magnet Synchronous Generator Project Work Dmitry Svechkarenko Royal Institute of Technology Department of Electrical Engineering Electrical Machines and

More information

Conventional Paper-I-2011 PART-A

Conventional Paper-I-2011 PART-A Conventional Paper-I-0 PART-A.a Give five properties of static magnetic field intensity. What are the different methods by which it can be calculated? Write a Maxwell s equation relating this in integral

More information

Synchronous Machines

Synchronous Machines Synchronous Machines Synchronous generators or alternators are used to convert mechanical power derived from steam, gas, or hydraulic-turbine to ac electric power Synchronous generators are the primary

More information

Lecture 05 Power in AC circuit

Lecture 05 Power in AC circuit CA2627 Building Science Lecture 05 Power in AC circuit Instructor: Jiayu Chen Ph.D. Announcement 1. Makeup Midterm 2. Midterm grade Grade 25 20 15 10 5 0 10 15 20 25 30 35 40 Grade Jiayu Chen, Ph.D. 2

More information

Electrical Machines-I Prof. D. Kastha Department of Electrical Engineering Indian Institute of Technology, Kharagpur

Electrical Machines-I Prof. D. Kastha Department of Electrical Engineering Indian Institute of Technology, Kharagpur Electrical Machines-I Prof. D. Kastha Department of Electrical Engineering Indian Institute of Technology, Kharagpur Lecture - 20 Potential and Current Transformers (Refer Slide Time: 00:37) So far we

More information

Power Quality. Guide for electrical design engineers. Power Quality. Mitigation of voltage unbalance

Power Quality. Guide for electrical design engineers. Power Quality. Mitigation of voltage unbalance Guide for electrical design engineers Power Quality Zbigniew Hanzelka GH-University of Science & Technology Mitigation of voltage unbalance U U = C = - = L U U = - U = - U Power Quality Power Quality.

More information

Review of DC Electric Circuit. DC Electric Circuits Examples (source:

Review of DC Electric Circuit. DC Electric Circuits Examples (source: Review of DC Electric Circuit DC Electric Circuits Examples (source: http://hyperphysics.phyastr.gsu.edu/hbase/electric/dcex.html) 1 Review - DC Electric Circuit Multisim Circuit Simulation DC Circuit

More information

Lesson 17: Synchronous Machines

Lesson 17: Synchronous Machines Lesson 17: Synchronous Machines ET 332b Ac Motors, Generators and Power Systems Lesson 17_et332b.pptx 1 Learning Objectives After this presentation you will be able to: Explain how synchronous machines

More information

Generators. What its all about

Generators. What its all about Generators What its all about How do we make a generator? Synchronous Operation Rotor Magnetic Field Stator Magnetic Field Forces and Magnetic Fields Force Between Fields Motoring Generators & motors are

More information

EE 742 Chapter 3: Power System in the Steady State. Y. Baghzouz

EE 742 Chapter 3: Power System in the Steady State. Y. Baghzouz EE 742 Chapter 3: Power System in the Steady State Y. Baghzouz Transmission Line Model Distributed Parameter Model: Terminal Voltage/Current Relations: Characteristic impedance: Propagation constant: π

More information

Fault Analysis Power System Representation

Fault Analysis Power System Representation .1. Power System Representation Single Line Diagram: Almost all modern power systems are three phase systems with the phases of equal magnitude and equal phase difference (i.e., 10 o ). These three phase

More information

Transient Stability Assessment of Synchronous Generator in Power System with High-Penetration Photovoltaics (Part 2)

Transient Stability Assessment of Synchronous Generator in Power System with High-Penetration Photovoltaics (Part 2) Journal of Mechanics Engineering and Automation 5 (2015) 401-406 doi: 10.17265/2159-5275/2015.07.003 D DAVID PUBLISHING Transient Stability Assessment of Synchronous Generator in Power System with High-Penetration

More information

Consider a simple RC circuit. We might like to know how much power is being supplied by the source. We probably need to find the current.

Consider a simple RC circuit. We might like to know how much power is being supplied by the source. We probably need to find the current. AC power Consider a simple RC circuit We might like to know how much power is being supplied by the source We probably need to find the current R 10! R 10! is VS Vmcosωt Vm 10 V f 60 Hz V m 10 V C 150

More information

Sinusoidal Response of RLC Circuits

Sinusoidal Response of RLC Circuits Sinusoidal Response of RLC Circuits Series RL circuit Series RC circuit Series RLC circuit Parallel RL circuit Parallel RC circuit R-L Series Circuit R-L Series Circuit R-L Series Circuit Instantaneous

More information

Power System Engineering Prof. Debapriya Das Department of Electrical Engineering Indian Institute of Technology, Kharagpur

Power System Engineering Prof. Debapriya Das Department of Electrical Engineering Indian Institute of Technology, Kharagpur Power System Engineering Prof. Debapriya Das Department of Electrical Engineering Indian Institute of Technology, Kharagpur Lecture 41 Application of capacitors in distribution system (Contd.) (Refer Slide

More information

Alternating Current. Symbol for A.C. source. A.C.

Alternating Current. Symbol for A.C. source. A.C. Alternating Current Kirchoff s rules for loops and junctions may be used to analyze complicated circuits such as the one below, powered by an alternating current (A.C.) source. But the analysis can quickly

More information

Model Reduction using a Frequency-Limited H 2 -Cost

Model Reduction using a Frequency-Limited H 2 -Cost Technical report from Automatic Control at Linköpings universitet Model Reduction using a Frequency-Limited H 2 -Cost Daniel Petersson, Johan Löfberg Division of Automatic Control E-mail: petersson@isy.liu.se,

More information

Review of Basic Electrical and Magnetic Circuit Concepts EE

Review of Basic Electrical and Magnetic Circuit Concepts EE Review of Basic Electrical and Magnetic Circuit Concepts EE 442-642 Sinusoidal Linear Circuits: Instantaneous voltage, current and power, rms values Average (real) power, reactive power, apparent power,

More information

Institutionen för systemteknik

Institutionen för systemteknik Institutionen för systemteknik Department of Electrical Engineering Examensarbete Dynamical Analysis and System Identification of the Gantry-Tau Parallel Manipulator Examensarbete utfört i Reglerteknik

More information

APPENDIX: TRANSMISSION LINE MODELLING AND PORT-BASED CIRCUITS

APPENDIX: TRANSMISSION LINE MODELLING AND PORT-BASED CIRCUITS APPENDIX: TRANSMISSION LINE MODELLING AND PORT-BASED CIRCUITS A. MODELLING TRANSMISSION LINES THROUGH CIRCUITS In Chapter 5 we introduced the so-called basic rule for modelling circuital systems through

More information

ELECTRO MAGNETIC INDUCTION

ELECTRO MAGNETIC INDUCTION ELECTRO MAGNETIC INDUCTION 1) A Circular coil is placed near a current carrying conductor. The induced current is anti clock wise when the coil is, 1. Stationary 2. Moved away from the conductor 3. Moved

More information

Institutionen för systemteknik

Institutionen för systemteknik Institutionen för systemteknik Department of Electrical Engineering Examensarbete Performance of Cooperative Relay Protocols over an Audio Channel Examensarbete utfört i Kommunikationssytem vid Tekniska

More information

LCR Series Circuits. AC Theory. Introduction to LCR Series Circuits. Module. What you'll learn in Module 9. Module 9 Introduction

LCR Series Circuits. AC Theory. Introduction to LCR Series Circuits. Module. What you'll learn in Module 9. Module 9 Introduction Module 9 AC Theory LCR Series Circuits Introduction to LCR Series Circuits What you'll learn in Module 9. Module 9 Introduction Introduction to LCR Series Circuits. Section 9.1 LCR Series Circuits. Amazing

More information

Investigation into the computational techniques of power system modelling for a DC railway

Investigation into the computational techniques of power system modelling for a DC railway Power Supply System Analysis, Design and Planning 123 Investigation into the computational techniques of power system modelling for a DC railway A. Finlayson 1, C. J. Goodman 2 & R. D. White 1 1 Atkins

More information

Institutionen för systemteknik Department of Electrical Engineering

Institutionen för systemteknik Department of Electrical Engineering Institutionen för systemteknik Department of Electrical Engineering Examensarbete Improved effort estimation of software projects based on metrics Examensarbete utfört i reglerteknik av Veronika Andersson

More information

Transmission Lines. Plane wave propagating in air Y unguided wave propagation. Transmission lines / waveguides Y. guided wave propagation

Transmission Lines. Plane wave propagating in air Y unguided wave propagation. Transmission lines / waveguides Y. guided wave propagation Transmission Lines Transmission lines and waveguides may be defined as devices used to guide energy from one point to another (from a source to a load). Transmission lines can consist of a set of conductors,

More information

Transmission and Distribution of Electrical Power

Transmission and Distribution of Electrical Power KINGDOM OF SAUDI ARABIA Ministry Of High Education Umm Al-Qura University College of Engineering & Islamic Architecture Department Of Electrical Engineering Transmission and Distribution of Electrical

More information

Induction_P1. 1. [1 mark]

Induction_P1. 1. [1 mark] Induction_P1 1. [1 mark] Two identical circular coils are placed one below the other so that their planes are both horizontal. The top coil is connected to a cell and a switch. The switch is closed and

More information

CLUSTER LEVEL WORK SHOP

CLUSTER LEVEL WORK SHOP CLUSTER LEVEL WORK SHOP SUBJECT PHYSICS QUESTION BANK (ALTERNATING CURRENT ) DATE: 0/08/06 What is the phase difference between the voltage across the inductance and capacitor in series AC circuit? Ans.

More information

Alternating Currents. The power is transmitted from a power house on high voltage ac because (a) Electric current travels faster at higher volts (b) It is more economical due to less power wastage (c)

More information

Application of linear analysis in traction power system stability studies

Application of linear analysis in traction power system stability studies Computers in Railways XI 401 Application of linear analysis in traction power system stability studies S. Danielsen, T. Toftevaag & O. B. Fosso Department of Electric Power Engineering, Norwegian University

More information

A relaxation of the strangeness index

A relaxation of the strangeness index echnical report from Automatic Control at Linköpings universitet A relaxation of the strangeness index Henrik idefelt, orkel Glad Division of Automatic Control E-mail: tidefelt@isy.liu.se, torkel@isy.liu.se

More information

Stepping Motors. Chapter 11 L E L F L D

Stepping Motors. Chapter 11 L E L F L D Chapter 11 Stepping Motors In the synchronous motor, the combination of sinusoidally distributed windings and sinusoidally time varying current produces a smoothly rotating magnetic field. We can eliminate

More information

Balanced three-phase systems and operation

Balanced three-phase systems and operation ELEC0014 - Introduction to power and energy systems Balanced three-phase systems and operation Thierry Van Cutsem t.vancutsem@ulg.ac.be www.montefiore.ulg.ac.be/~vct October 2017 1 / 17 system used for

More information

BASIC NETWORK ANALYSIS

BASIC NETWORK ANALYSIS SECTION 1 BASIC NETWORK ANALYSIS A. Wayne Galli, Ph.D. Project Engineer Newport News Shipbuilding Series-Parallel dc Network Analysis......................... 1.1 Branch-Current Analysis of a dc Network......................

More information

POWER SYSTEM STABILITY

POWER SYSTEM STABILITY LESSON SUMMARY-1:- POWER SYSTEM STABILITY 1. Introduction 2. Classification of Power System Stability 3. Dynamic Equation of Synchronous Machine Power system stability involves the study of the dynamics

More information

EE2351 POWER SYSTEM ANALYSIS UNIT I: INTRODUCTION

EE2351 POWER SYSTEM ANALYSIS UNIT I: INTRODUCTION EE2351 POWER SYSTEM ANALYSIS UNIT I: INTRODUCTION PART: A 1. Define per unit value of an electrical quantity. Write equation for base impedance with respect to 3-phase system. 2. What is bus admittance

More information

Institutionen för datavetenskap Department of Computer and Information Science

Institutionen för datavetenskap Department of Computer and Information Science Institutionen för datavetenskap Department of Computer and Information Science Final thesis Conditional Planning for Troubleshooting and Repair in a Partially Observable Environment by Håkan Warnquist

More information

Single Phase Parallel AC Circuits

Single Phase Parallel AC Circuits Single Phase Parallel AC Circuits 1 Single Phase Parallel A.C. Circuits (Much of this material has come from Electrical & Electronic Principles & Technology by John Bird) n parallel a.c. circuits similar

More information

Toolbox: Electrical Systems Dynamics

Toolbox: Electrical Systems Dynamics Toolbox: Electrical Systems Dynamics Dr. John C. Wright MIT - PSFC 05 OCT 2010 Introduction Outline Outline AC and DC power transmission Basic electric circuits Electricity and the grid Image removed due

More information

Power Electronics

Power Electronics Prof. Dr. Ing. Joachim Böcker Power Electronics 3.09.06 Last Name: Student Number: First Name: Study Program: Professional Examination Performance Proof Task: (Credits) (0) (0) 3 (0) 4 (0) Total (80) Mark

More information

Module 7. Transformer. Version 2 EE IIT, Kharagpur

Module 7. Transformer. Version 2 EE IIT, Kharagpur Module 7 Transformer ersion EE T, Kharagpur Lesson 5 Testing, Efficiency & Regulation ersion EE T, Kharagpur Contents 5 Testing, Efficiency & regulation 4 5. Goals of the lesson.. 4 5. Determination of

More information

Electromagnetic Oscillations and Alternating Current. 1. Electromagnetic oscillations and LC circuit 2. Alternating Current 3.

Electromagnetic Oscillations and Alternating Current. 1. Electromagnetic oscillations and LC circuit 2. Alternating Current 3. Electromagnetic Oscillations and Alternating Current 1. Electromagnetic oscillations and LC circuit 2. Alternating Current 3. RLC circuit in AC 1 RL and RC circuits RL RC Charging Discharging I = emf R

More information

Brief Steady of Power Factor Improvement

Brief Steady of Power Factor Improvement International Journal of Electrical Engineering. ISSN 0974-2158 Volume 6, Number 5 (2013), pp. 531-539 International Research PublicationHouse http://www.irphouse.com Brief Steady of Power Factor Improvement

More information

The output voltage is given by,

The output voltage is given by, 71 The output voltage is given by, = (3.1) The inductor and capacitor values of the Boost converter are derived by having the same assumption as that of the Buck converter. Now the critical value of the

More information

Boise State University Department of Electrical and Computer Engineering ECE 212L Circuit Analysis and Design Lab

Boise State University Department of Electrical and Computer Engineering ECE 212L Circuit Analysis and Design Lab Objectives Boise State University Department of Electrical and Computer Engineering ECE 22L Circuit Analysis and Design Lab Experiment #4: Power Factor Correction The objectives of this laboratory experiment

More information

Lecture 9 Time Domain vs. Frequency Domain

Lecture 9 Time Domain vs. Frequency Domain . Topics covered Lecture 9 Time Domain vs. Frequency Domain (a) AC power in the time domain (b) AC power in the frequency domain (c) Reactive power (d) Maximum power transfer in AC circuits (e) Frequency

More information

Solved Problems. Electric Circuits & Components. 1-1 Write the KVL equation for the circuit shown.

Solved Problems. Electric Circuits & Components. 1-1 Write the KVL equation for the circuit shown. Solved Problems Electric Circuits & Components 1-1 Write the KVL equation for the circuit shown. 1-2 Write the KCL equation for the principal node shown. 1-2A In the DC circuit given in Fig. 1, find (i)

More information

Transient Analysis of Doubly Fed Wind Power Induction Generator Using Coupled Field-Circuit Model

Transient Analysis of Doubly Fed Wind Power Induction Generator Using Coupled Field-Circuit Model Publication P2 Seman, S., Kanerva, S., Niiranen, J., Arkkio, A. 24. Transient Analysis of Wind Power Doubly Fed Induction Generator Using Coupled Field Circuit Model, Proceedings of ICEM 24, 5-8 September

More information

Power Factor Improvement

Power Factor Improvement Salman bin AbdulazizUniversity College of Engineering Electrical Engineering Department EE 2050Electrical Circuit Laboratory Power Factor Improvement Experiment # 4 Objectives: 1. To introduce the concept

More information

EE 6501 POWER SYSTEMS UNIT I INTRODUCTION

EE 6501 POWER SYSTEMS UNIT I INTRODUCTION EE 6501 POWER SYSTEMS UNIT I INTRODUCTION PART A (2 MARKS) 1. What is single line diagram? A Single line diagram is diagrammatic representation of power system in which the components are represented by

More information

LESSON 20 ALTERNATOR OPERATION OF SYNCHRONOUS MACHINES

LESSON 20 ALTERNATOR OPERATION OF SYNCHRONOUS MACHINES ET 332b Ac Motors, Generators and Power Systems LESSON 20 ALTERNATOR OPERATION OF SYNCHRONOUS MACHINES 1 LEARNING OBJECTIVES After this presentation you will be able to: Interpret alternator phasor diagrams

More information

On Consistency of Closed-loop Subspace Identifictaion with Innovation Estimation

On Consistency of Closed-loop Subspace Identifictaion with Innovation Estimation Technical report from Automatic Control at Linköpings universitet On Consistency of Closed-loop Subspace Identictaion with Innovation Estimation Weilu Lin, S Joe Qin, Lennart Ljung Division of Automatic

More information

Fault Calculation Methods

Fault Calculation Methods ELEC9713 Industrial and Commercial Power Systems Fault Calculation Methods There are two major problems that can occur in electrical systems: these are open circuits and short circuits. Of the two, the

More information

Week No. 6 Chapter Six: Power Factor Improvement

Week No. 6 Chapter Six: Power Factor Improvement Week No. 6 Chapter Six: Power Factor Improvement The electrical energy is almost wholly generated, transmitted and distributed in the form of alternating current. Therefore, the question of power factor

More information

SECOND ENGINEER REG III/2 MARINE ELECTRO-TECHNOLOGY. 1. Understands the physical construction and characteristics of basic components.

SECOND ENGINEER REG III/2 MARINE ELECTRO-TECHNOLOGY. 1. Understands the physical construction and characteristics of basic components. SECOND ENGINEER REG III/ MARINE ELECTRO-TECHNOLOGY LIST OF TOPICS A B C D Electric and Electronic Components Electric Circuit Principles Electromagnetism Electrical Machines The expected learning outcome

More information

Chapter 9: Transient Stability

Chapter 9: Transient Stability Chapter 9: Transient Stability 9.1 Introduction The first electric power system was a dc system built by Edison in 1882. The subsequent power systems that were constructed in the late 19 th century were

More information