1 Achim J. Lilienthal Erik Schaffernicht Mobile Achim J. Achim J. Lilienthal Room T1222 Robotics and Lilienthal Olfaction Room T1211 Lab, Erik Schaffernicht AASS, Örebro University (often away please drop me an in advance) (often there please drop me an anyway) 46
2 2. Further Gas Sensing Technologies for Mobile Robots Beyond the Classical Electronic Nose o Optical sensor systems o Mass spectrometry (MS) 47
3 2. Mass Spectrometry (MS) Mass Spectrometry o Ionization of compounds 48
4 2. Mass Spectrometry (MS) Mass Spectrometry o Ionization of compounds o Separation according to m/z» with electric or magnetic field 49
5 2. Mass Spectrometry (MS) Mass Spectrometry o Ionization of compounds o Separation according to m/z» with electric or magnetic field o Detection of the ions with an electron multiplier 51
6 2. Mass Spectrometry (MS) Mass Spectrometry o Ionization of compounds o Separation according to m/z» with electric or magnetic field o Detection of the ions with an electron multiplier o Disadvantages for robotics» Ionization unit required» Vacuum is required Not very convenient Costly 52
7 2. Further Gas Sensing Technologies for Mobile Robots Beyond the Classical Electronic Nose o Optical sensor systems o Mass spectrometry o Ion mobility spectrometry (IMS) 53
8 2. Ion Mobility Spectrometry (IMS) Ion Mobility Spectrometry o Separation of ions by m/z and mobility Strukturuntersuchungen an (C60) n +-Clustern mit MRO-IPW'16 der Methode A. der J. Lilienthal Gasphasen-Ionenchromatographie & E. Schaffernicht (Sep 12, [Lilienthal 2016) 1998] 54
9 2. Ion Mobility Spectrometry (IMS) Ion Mobility Spectrometry o Separation of ions by m/z and mobility» Ionization of compounds Strukturuntersuchungen an (C60) n +-Clustern mit MRO-IPW'16 der Methode A. der J. Lilienthal Gasphasen-Ionenchromatographie & E. Schaffernicht (Sep 12, [Lilienthal 2016) 1998] 55
10 2. Ion Mobility Spectrometry (IMS) Ion Mobility Spectrometry o Separation of ions by m/z and mobility» Ionization of compounds» Separation of m/z Strukturuntersuchungen an (C60) n +-Clustern mit MRO-IPW'16 der Methode A. der J. Lilienthal Gasphasen-Ionenchromatographie & E. Schaffernicht (Sep 12, [Lilienthal 2016) 1998] 56
11 2. Ion Mobility Spectrometry (IMS) Ion Mobility Spectrometry o Separation of ions by m/z and mobility» Ionization of compounds» Separation of m/z» Pulsed introduction to a drift region Larger ions with greater collision cross section are slower due to more collisions Strukturuntersuchungen an (C60) n +-Clustern mit MRO-IPW'16 der Methode A. der J. Lilienthal Gasphasen-Ionenchromatographie & E. Schaffernicht (Sep 12, [Lilienthal 2016) 1998] 57
12 2. Ion Mobility Spectrometry (IMS) Ion Mobility Spectrometry o Separation of ions by m/z and mobility» Ionization of compounds» Separation of m/z» Pulsed introduction to a drift region» Detection of ion current Strukturuntersuchungen an (C60) n +-Clustern mit MRO-IPW'16 der Methode A. der J. Lilienthal Gasphasen-Ionenchromatographie & E. Schaffernicht (Sep 12, [Lilienthal 2016) 1998] 58
13 2. Ion Mobility Spectrometry (IMS) Ion Mobility Spectrometry o Separation of ions by m/z and mobility» Ionization of compounds» Separation of m/z» Pulsed introduction to a drift region» Detection of ion current o Disadvantages for robotics» Ionization unit required» Ion-ion interaction causes problems in complex mixtures» Drift cell with inert gas required (isolated from atmospheric air) Not very convenient Costly 59
14 2. Photoionization Detector (PID) Photoionization Detector (VOC monitor) o MS/IMS without m/z and mobility separation 60
15 2. Photoionization Detector (PID) Photoionization Detector (VOC monitor) o MS/IMS without m/z and mobility separation o Ionization with UV lamp» Max ev in RAE PIDs ( ethanol, acetone, methanol)» Cannot detect methane (IP between 12.6 and 13.6 ev [URL]) o Detection of current o Pros» Quick response to a wide range of gases» Calibrated readings if there is only one, known compound o Cons» Not suitable for classification» Too bulky (?)» Expensive 61
16 3 Signal Processing in Electronic Noses 64
17 3. E-Nose Signal Processing Components of an E-Nose Approach o Sampling system o Sensor array (physical or virtual) o Data evaluation algorithms» Reference data set Tasks o Detection o Discrimination o Identification o Quantification 66
18 3. E-Nose Signal Processing Components of an E-Nose Approach o Sampling system Traditional three-phase sampling Continuous (open) sampling with a mobile robot 67
19 3. E-Nose Signal Processing Components of an E-Nose Approach o Sampling system o Sensor array (physical or virtual)» Sensors with partial selectivity» Output of sensors is usually one feature per sensor (at a time) Resistance, fundamental frequency shift, etc. Preferably during an equilibrium-type or steady-state-type situation» Sensor array corresponds to feature space 68
20 3. E-Nose Signal Processing Components of an E-Nose Approach o Sampling system o Sensor array (physical or virtual)» Output of sensors is usually one feature per sensor (at a time)» Sensor array corresponds to feature space o Data evaluation algorithms» Data analysis using e.g. pattern recognition tools 69
21 4 Electronic Nose Applications 74
22 4. Electronic Nose Applications Application Areas o Food and beverage control ( human sense of smell) o Fire warning ( human sense of smell) o Pollution monitoring ( human sense of smell)» Environmental monitoring o Detection of hazardous substances and explosives (security macrosmatic mammals such as dogs) o Disease diagnosis» Lung cancer» Bacteria in blood o etc. 75
23 4. Electronic Nose Applications Application Areas o Food and beverage control ( human sense of smell) o Fire warning ( human sense of smell) o Pollution monitoring ( human sense of smell)» Environmental monitoring o Detection of hazardous substances and explosives (security macrosmatic mammals such as dogs) o Disease diagnosis» Lung cancer» Bacteria in blood o etc. 77
24 4. Electronic Nose Applications Environmental Monitoring o Detection of toxic compounds in the ambient atmosphere» At concentrations which will not have an immediate effect but are a longterm danger for human health Carbon monoxide, nitrogen oxides, sulfur oxides, volatile organic compounds, ammonia, ozone, and particulate matter» Compounds that are simply unpleasant 78
25 4. Electronic Nose Applications Environmental Monitoring o Detection of toxic compounds in the ambient atmosphere o Analytical instruments do not allow dense, continuous sampling o However, using e-noses is very challenging» Complex mixtures» Low detection thresholds» Sampling (where? when?) Samples must be representative and independent of variable ambient conditions Knowledge of spatial and time patterns of concentrations is important» Changes in temperature and humidity Sample pre-treatment and parametric compensation 79
26 4. Electronic Nose Applications Environmental Monitoring o Detection of toxic compounds in the ambient atmosphere o Analytical instruments do not allow dense, continuous sampling o However, using e-noses is very challenging» Complex mixtures» Low detection thresholds» Sampling (where? when?) Samples must be representative and independent of variable ambient conditions Knowledge of spatial and time patterns of concentrations is important» Changes in temperature and humidity Sample pre-treatment and parametric compensation 80
27 4. Electronic Nose Applications Environmental Monitoring o For application the sensitivity of the electronic nose to the target substances and to potential interferents has to be known 81
28 4. Electronic Nose Applications Environmental Monitoring o For application the sensitivity of the electronic nose to the target substances and to potential interferents has to be known [Röck et al. 2008] 83
29 5 Literature 91
30 5. Literature Literature o [Pearce et al. 2003]» Handbook of Machine Olfaction Chapter 4 92
31 5. Literature Literature o [Pearce et al. 2003] o [Röck et al. 2008]» Electronic Nose: Current Status and Future Trends, Chem. Rev. 2008, 108,
32 5. Literature Literature o [Pearce et al. 2003] o [Röck et al. 2008] o [Hierlemann/Gutierrez-Osuna 2008]» Higher-Order Chemical Sensing, A. Hierlemann and R. Gutierrez-Osuna. Chem. Rev. 2008, 108,
33 5. Literature Literature o [Pearce et al. 2003] o [Röck et al. 2008] o [Hierlemann/Gutierrez-Osuna 2008] o [Gardner/Bartlett 1999] Electronic Noses Principles and Applications, J. W. Gardner and P. N. Bartlett. Oxford Science Publications,
34 5. Literature Literature o [Pearce et al. 2003] o [Röck et al. 2008] o [Hierlemann/Gutierrez-Osuna 2008] o [Persaud and Dodd 1982]» Analysis of Discrimination Mechanisms in the Mammalian Olfactory System using a Model Nose. Nature, 1982, 299, o [Kreutz et al. 2006]» High Frequency QuartzMicro Balances: A Promising Path to Enhanced Sensitivity of Gravimetric Sensors. Sensors 2006, 6,
35 Achim J. Lilienthal Erik Schaffernicht Mobile Achim J. Achim J. Lilienthal Room T1222 Robotics and Lilienthal Olfaction Room T1211 Lab, Erik Schaffernicht AASS, Örebro University (often away please drop me an in advance) (often there please drop me an anyway) 97
AASS, Örebro University
Mobile Robotics Achim J. and Lilienthal Olfaction Lab, AASS, Örebro University 1 Contents 1. "Classical" Electronic Nose 2. Further Gas Sensing Technologies for Mobile Robots 3. (Signal Processing in Electronic
More informationRS DYNAMICS ECOPROBE 5. Portable IR/PID Gas Analyzer PID. PID and IR Analyzers
RS DYNAMICS ECOPROBE 5 Portable IR/PID Gas Analyzer PID + IR PID and IR Analyzers General ECOPROBE 5 has two autonomous analyzers in one case. The combination of analyzers provides a set of data designed
More informationAASS, Örebro University
Mobile Robotics Achim J. and Lilienthal Olfaction Lab, AASS, Örebro University 1 Contents 1. Gas-Sensitive Mobile Robots in the Real World 2. Gas Dispersal in Natural Environments 3. Gas Quantification
More informationQuestions, Myths and Misconceptions about Using Photoionization Detectors
Questions, Myths and Misconceptions about Using Photoionization Detectors Solvent, fuel and other VOC vapours are pervasively common in many workplace environments. Increased awareness of the toxicity
More informationWhite Paper. Overview: NDIR Definition:
Title: NDIR Technology Overview, Compliance, and Comparison to Other Generally Available Gas Measurement Technologies TSN Number: 06 File:\\MII- SRV1\Metron\Bridge_Analyzers\Customer_Service_Documentation\White_Papers\06
More information8.8 - Gases. These are assumptions that can be made about 99% of the gases we come in contact with which are called ideal gases.
Gases The substance that we come in contact with every second of every day is in fact the substance we never think about. This substance is a mixture of gases known as the atmosphere. Gases have the weakest
More informationUsing 11.7eV PID Lamps To Accurately Measure VOCs With Ionization Energy Above 10.6eV
Using 11.7eV PID Lamps To Accurately Measure VOCs With Ionization Energy Above 10.6eV Summary Honeywell RAE Systems strongly recommends using 100 ppm propane as calibration gas for instruments with 11.7eV
More informationMiniaturized Sensor for the Detection of Environmental Pollutants Alexander Graf 1, Ronald Stübner 1, Christian Kunath 1, Sebastian Meyer 1, Harald Schenk 1 1 Fraunhofer Institute for Photonic Microsystems
More informationTraining Coarse ECOPROBE 5 CHEMISTRY RS DYNAMICS
Training Coarse ECOPROBE 5 CHEMISTRY Contents Ecoprobe analytical principles Photoionization Infrared spectroscopy Oxygen measurement Pollutants Types and responses Head space New application of Ecoprobe
More informationUV Hound Series. Dependable High Quality Air Monitoring. Accurate Readings Within Seconds. Portable UVDOAS Multi-gas Analyzers. Multi-Gas Capability
UV Hound Series Portable UVDOAS Multi-gas Analyzers Multi-Gas Capability Dependable High Quality Air Monitoring Individual VOCs PPB Sensitivity Non-Contact Optical Measurement Automated Reporting Configurable
More informationWarning!! Chapter 5 Gases. Chapter Objectives. Chapter Objectives. Chapter Objectives. Air Pollution
Warning!! Larry Brown Tom Holme www.cengage.com/chemistry/brown Chapter 5 Gases These slides contains visual aids for learning BUT they are NOT the actual lecture notes! Failure to attend to lectures most
More informationInvestigation of FIGARO TGS2620 under different Chemical Environment
Investigation of FIGARO TGS2620 under different Chemical Environment Joyita Chakraborty 1, Abhishek Paul 2 1 Department of A.E.I.E, 2 Department of E.C.E Camellia Institute of Technology Kolkata, India
More informationUV3000. Accurate, precise, and portable ambient gas point analyzer
UV3000 Accurate, precise, and portable ambient gas point analyzer The Cerex UV3000 is a multifunction analyzer designed to detect part per billion (ppb) to percent level concentrations of multiple gases
More informationIon Trajectories in the Injection Quadrupole for SIFT-MS
WDS' Proceedings of Contributed Papers, Part II, 44 48, 0. ISBN 978-80-7378-5- MATFYZPRESS Ion Trajectories in the Injection Quadrupole for SIFT-MS A. Spesyvyi Charles University Prague, Faculty of Mathematics
More informationPrima PRO Process Mass Spectrometer
APPLICATION NOTE Prima PRO Process Mass Spectrometer No. xxxx Controlling emissions by multi-component analysis of Volatile Organic Compounds (VOC) Authors: Peter Traynor, Thermo Fisher Scientific, Franklin,
More informationEdward J. Staples Page ONDCP INTERNATIONAL TECHNOLOTGY SYMPOSIUM March 8-10, 1999 Washington, DC
Edward J. Staples Page 1 The Electronic Nose--A New Law Enforcement Tool Edward J. Staples Electronic Sensor Technology, LP 1107 Business Center Circle, Newbury Park, CA Tele: (805)480-1994, FAX (805)480-1984
More informationIntroduction to Mass Spectrometry (MS)
Introduction to Mass Spectrometry (MS) MS Mass Spectrometry (MS) This is a very powerful analytical tool that can provide information on both molecular mass and molecular structure. Molecules come in all
More informationDEPARTMENT OF ELECTRONICS AND INSTRUMENTATION ENGINEERING SRM NAGAR, KATTANKULATHUR-603203 EI 2302 ANALYTICAL INSTRUMENTS QUESTION BANK UNIT I COLORIMETRY AND SPECTROPHOTOMETRY Part A 1. State Lambert
More informationUnderstanding catalytic LEL combustible gas sensor performance
: Understanding catalytic LEL combustible gas sensor performance These four conditions are frequently diagrammed as the "Fire Tetrahedron". If any side of the tetrahedron is missing, incomplete or insubstantial;
More informationCatalytic bead sensors are used primarily to detect
Chapter 3 Catalytic Combustible Gas Sensors Catalytic bead sensors are used primarily to detect combustible gases. They have been in use for more than 50 years. Initially, these sensors were used for monitoring
More informationSIFT-MS SELECTED ION FLOW TUBE MASS SPECTROMETRY TECHNOLOGY OVERVIEW
SIFT-MS SELECTED ION FLOW TUBE MASS SPECTROMETRY TECHNOLOGY OVERVIEW NEXT GENERATION MASS SPECTROMETRY CONTENTS: 3 How SIFT-MS works 4 Soft chemical ionisation 5 Quantification in real-time 6 Utilising
More informationHarris: Quantitative Chemical Analysis, Eight Edition CHAPTER 23: GAS CHROMATOGRAPHY
Harris: Quantitative Chemical Analysis, Eight Edition CHAPTER 23: GAS CHROMATOGRAPHY Chapter 23. Gas Chromatography What did they eat in the year 1,000? GC of Cholesterol and other lipids extracted from
More informationAtmospheric Analysis Gases. Sampling and analysis of gaseous compounds
Atmospheric Analysis Gases Sampling and analysis of gaseous compounds Introduction - External environment (ambient air) ; global warming, acid rain, introduction of pollutants, etc - Internal environment
More informationSustainable Human Resource Development in logistics services for ASEAN Member States
The Training Material on Dangerous Goods Handling (All modes) has been produced under Project Sustainable Human Resource Development in Logistic Services for ASEAN Member States with the support from Japan-ASEAN
More informationALE 1. Chemical Kinetics: Rates of Chemical Reactions
Name Chem 163 Section: Team Number: ALE 1. Chemical Kinetics: Rates of Chemical Reactions (Reference: Sections 16.1 16.2 + parts of 16.5 16.6 Silberberg 5 th edition) How do the surface area, concentration
More informationProudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment
www.ietltd.com Proudly serving laboratories worldwide since 1979 CALL +1.847.913.0777 for Refurbished & Certified Lab Equipment Applied Biosystems QStar Pulsar i Features of the API QSTAR Pulsar i The
More informationMARIYA INTERNATIONAL SCHOOL. Work sheet II. Term II. Level 8 Chemistry [Paper IV] Name: SULFUR AND AIR AND WATER
MARIYA INTERNATIONAL SCHOOL Work sheet II Term II Level 8 Chemistry [Paper IV] Name: SULFUR AND AIR AND WATER 1. Nitrogen dioxide and other oxides of nitrogen are formed in car engines. a) Explain how
More informationSampling for Gases and Vapors
Sampling for Gases and Vapors EOH 466B Evaluating the Occupational Environment Spring 2008 Gases and Vapors Gases: don't exist in liquid state at STP e.g.: nitrous oxides, ozone, carbon monoxide Vapors:
More informationVALLIAMMAI ENGINEERING COLLEGE SRM Nagar, Kattankulathur
VALLIAMMAI ENGINEERING COLLEGE SRM Nagar, Kattankulathur 603 203 DEPARTMENT OF ELECTRONICS AND INSTRUMENTATION ENGINEERING QUESTION BANK V SEMESTER EI6501 Analytical Instruments Regulation 2013 Academic
More informationThe Globally Harmonized System (GHS) for Hazard Classification and Labelling. Development of a Worldwide System for Hazard Communication
The Globally Harmonized System (GHS) for Hazard Classification and Labelling Development of a Worldwide System for Hazard Communication Why is the GHS needed? No country has the ability to identify and
More informationTechnical/Application Article 01 Version 1.2
Technical/Application Article 01 Version 1.2 th 25 January 2017 WRH What is a PID? Introduction PID is the abbreviation for Photo-Ionization Detector. A PID is a hand-held, personal, or fixed wallmounted
More informationMass Spectrometry. What is Mass Spectrometry?
Mass Spectrometry What is Mass Spectrometry? Mass Spectrometry (MS): The generation of gaseous ions from a sample, separation of these ions by mass-to-charge ratio, and measurement of relative abundance
More informationCombustion Generated Pollutants
Combustion Generated Pollutants New Delhi Peking Climate change Combustion Generated Pollutants Greenhouse gases: CO 2, methane, N 2 O, CFCs, particulates, etc. Hydrocarbons: Toxins and a major contributor
More informationIntroduction of Hitachi Chromaster 5610 MS Detector for High Performance Liquid Chromatograph
SCIETIFIC ISTRUMET EWS 2016 Vol. 7 SEPTEMBER Technical magazine of Electron Microscope and Analytical Instruments. Technical Explanation Introduction of Hitachi Chromaster 5610 MS Detector for High Performance
More informationChapter 3 Matter and Energy
Introductory Chemistry, 3 rd Edition Nivaldo Tro Matter and Energy The chapter opening (page 52) showing a room and highlighting the structure of water and the carbon atoms in a graphite tennis racket
More informationGas Chromatography (GC)! Environmental Organic Chemistry CEE-PUBH Analysis Topic 5
Gas Chromatography (GC)! Environmental Organic Chemistry CEE-PUBH 5730-6730 Analysis Topic 5 Chromatography! Group of separation techniques based on partitioning (mobile phase/stationary phase). Two immiscible
More informationStrategies For Selecting Air Sampling Methods AIHA-Florida Section Spring Conference
Strategies For Selecting Air Sampling Methods 2011 AIHA-Florida Section Spring Conference Course Outline What are we going to sample for Sampling media Active sampling, diffusive samplers, direct read
More informationUNIVERSITY OF CALIFORNIA College of Engineering Department of Electrical Engineering and Computer Sciences. Professor Ali Javey. Spring 2009.
UNIVERSITY OF CALIFORNIA College of Engineering Department of Electrical Engineering and Computer Sciences EE143 Professor Ali Javey Spring 2009 Exam 1 Name: SID: Closed book. One sheet of notes is allowed.
More informationBiology Combined Chemistry Combined Physics Combined. Content Hours Content Hours Content Hours
Biology Combined Chemistry Combined Physics Combined Content Hours Content Hours Content Hours Half Term.7.. Communities Competition Ecosystems Interdependence ASSESSED HOMEWORK (Communities).7.. Abiotic
More informationHow to complete this assignment
How to complete this assignment This course consists of a PDF document that follows this page. To receive credit for completing the course, you must confirm you have read and understood the material that
More informationChemistry 311: Topic 3 - Mass Spectrometry
Mass Spectroscopy: A technique used to measure the mass-to-charge ratio of molecules and atoms. Often characteristic ions produced by an induced unimolecular dissociation of a molecule are measured. These
More informationDetermination of Volatile Substances Proof of Food Adulteration
ANALYSIS OF FOOD AND NATURAL PRODUCTS LABORATORY EXERCISE Determination of Volatile Substances Proof of Food Adulteration (method: gas chromatography with mass spectrometric detection) Exercise guarantor:
More informationCHAPTER D3 TOF ION OPTICS
Back to Basics Section D: Ion Optics CHAPTER D3 TOF ION OPTICS TABLE OF CONTENTS QuickGuide...399 Summary...401 Background...403 EquationsofMotionofIons...403 Resolution...405 Reflectron...407 Comparison
More informationInstrumental Analysis
Instrumental Analysis Bonds and Infrared Energy Covalent bonds can absorb infrared energy, which causes the bonds to vibrate. Depending on the masses of the bonded atoms, different frequencies of radiation
More informationFundamentals of Mass Spectrometry. Fundamentals of Mass Spectrometry. Learning Objective. Proteomics
Mass spectrometry (MS) is the technique for protein identification and analysis by production of charged molecular species in vacuum, and their separation by magnetic and electric fields based on mass
More informationVolatile organic compounds (VOCs):
Volatile organic compounds (VOCs): Organic chemicals with a high vapour pressure at room temperature. High vapour pressure results from a low boiling point. The World Health Organization (WHO) defined
More informationReal Time On-Site Odor and VOC Emission Measurements Using a znose
Real Time On-Site Odor and VOC Emission Measurements Using a znose Edward J. Staples, Electronic Sensor Technology, EST@ESTCAL.COM Remediation Site Description Remediation of contaminated soil from where
More informationDrift Reduction For Metal-Oxide Sensor Arrays Using Canonical Correlation Regression And Partial Least Squares
Drift Reduction For Metal-Oxide Sensor Arrays Using Canonical Correlation Regression And Partial Least Squares R Gutierrez-Osuna Computer Science Department, Wright State University, Dayton, OH 45435,
More information4.1.1 A simple model of the atom, symbols, relative atomic mass, electronic charge and isotopes. Unit 1 Unit 2 Unit 3. C2.1.1a Structure and bonding
Summary of changes This resource outlines the main changes that have been made to the assessment and subject content from our previous GCSE Chemistry (4402) to the new specification (8462). Our new specifications
More informationChemistry. Matter is anything that has mass and takes up space.
Chemistry When faced with the question: what is chemistry? you might give an answer like - the study of chemicals. When faced with another question like: what are chemicals? you probably would answer with
More informationII. WAVELENGTH SELECTION
Ozone detection by DFB QCL absorption technique using Multipass cell S.S. Yenaganti 1, S.S.Kulkarni 2, A.J.Verma 3, N.Sreevalsen 4, V.Rathore 5 1 Department of Electronics and Telecommunications Engineering,
More informationLIQUID CHROMATOGRAPHY-MASS SPECTROMETRY (LC/MS) Presented by: Dr. T. Nageswara Rao M.Pharm PhD KTPC
LIQUID CHROMATOGRAPHY-MASS SPECTROMETRY (LC/MS) Presented by: Dr. T. Nageswara Rao M.Pharm PhD KTPC INTRODUCTION Principle: LC/MS is a technique that combines physical separation capabilities of liquid
More informationRosemary extract liquid
EUROPEAN COMMISSION DIRECTORATE-GENERAL JOINT RESEARCH CENTRE Institute for Reference Materials and Measurements Community Reference Laboratory - Feed Additives Authorisation Evaluation Report of the Community
More informationThermogravimetric Analysis Advanced Techniques for Better Materials Characterisation
Thermogravimetric Analysis Advanced Techniques for Better Materials Characterisation Philip Davies TA Instruments UK Thermogravimetric Analysis Change in a samples weight (increase or decrease) as a function
More informationCracking. 191 minutes. 186 marks. Page 1 of 27
3.1.6.2 Cracking 191 minutes 186 marks Page 1 of 27 Q1. (a) Gas oil (diesel), kerosine (paraffin), mineral oil (lubricating oil) and petrol (gasoline) are four of the five fractions obtained by the fractional
More informationMonitoring Flammable Vapors and Gases in Industrial Processes
Flammability Hazards Industrial fires and explosions happen more frequently than most people think. They cause downtime, property damage, injury and sometimes death. These fires and explosions result from
More information2B Technologies, Inc. An InDevR Company
2B Technologies, Inc. An InDevR Company Technical Note No. 40 UV-Absorbing Interferences in Ozone Monitors Date: 22 April 2015 Author: John Birks Background Ozone measurements by absorbance of the 253.7-nm
More informationLab 3 Guide: Gas Chromatography (GC) (Sept 8-14)
Lab 3 Guide: Gas Chromatography (GC) (Sept 8-14) How GC works The Basic Idea Gas chromatography (GC) is mainly used for the qualitative analysis of samples: it answers the question What chemicals are present
More informationProf. Katherine Candler! E80 - Spring 2013!!!!! (Notes adapted from Prof. Qimin Yang s lecture, Spring 2011)!
Prof. Katherine Candler E80 - Spring 2013 (Notes adapted from Prof. Qimin Yang s lecture, Spring 2011) } http://www.eng.hmc.edu/newe80/flightvideos.html } (just for fun): http://www.youtube.com/watch?v=mqwlmgr6bpa
More informationMass Spectrometry. Electron Ionization and Chemical Ionization
Mass Spectrometry Electron Ionization and Chemical Ionization Mass Spectrometer All Instruments Have: 1. Sample Inlet 2. Ion Source 3. Mass Analyzer 4. Detector 5. Data System http://www.asms.org Ionization
More informationATOC 3500/CHEM 3152 Week 9, March 8, 2016
ATOC 3500/CHEM 3152 Week 9, March 8, 2016 Hand back Midterm Exams (average = 84) Interaction of atmospheric constituents with light Haze and Visibility Aerosol formation processes (more detail) Haze and
More informationGRAPHENE FLAGSHIP TECHNOLOGIES
IOT AND SENSORS DATACOM HEALTH ENERGY COMPOSITES GRAPHENE FLAGSHIP TECHNOLOGIES IOT AND SENSORS CHROMATIC EYE The chromatic eye contains many different graphene photodetectors. This is a broadband sensor
More informationFactors Affecting Reaction Rate
Factors Affecting Reaction Rate Outcomes: Formulate an operational definition of reaction rate. State the collision theory. Perform a lab to identify factors that affect reaction rate. Describe, qualitatively,
More informationMass spectrometry is an important part of multicomponent analytical systems designed for diagnosis of metabolic disorders. About 50 different
Dr Mosaddegh Mass spectrometry is an important part of multicomponent analytical systems designed for diagnosis of metabolic disorders. About 50 different diseases with increased excretion of organic
More informationInertization Effects on the Explosion Parameters of Different Mix Ratios of Ethanol and Toluene Experimental Studies
111 This article is available in PDF-format, in colour, at: www.wydawnictwa.ipo.waw.pl/materialy-wysokoenergetyczne.html Materiały Wysokoenergetyczne / High-Energetic Materials, 2016, 8, 111 117 ISSN 2083-0165
More informationGlobal Harmonization and Hazard Communication
Global Harmonization and Hazard Communication HAZARD COMMUNICATION Major changes to the Hazard Communication Standard Hazard classification: Chemical manufacturers and importers are required to determine
More informationMASS ANALYSER. Mass analysers - separate the ions according to their mass-to-charge ratio. sample. Vacuum pumps
ION ANALYZERS MASS ANALYSER sample Vacuum pumps Mass analysers - separate the ions according to their mass-to-charge ratio MASS ANALYSER Separate the ions according to their mass-to-charge ratio in space
More informationAUTOMATED ONLINE IDENTIFICATION AND MONITORING OF IMPURITIES IN GASES
JPACSM 127 AUTOMATED ONLINE IDENTIFICATION AND MONITORING OF IMPURITIES IN GASES Trace Analytical Inc. Menlo Park, CA ABSTRACT GC based gas analyzers with Reduction Gas Detector (RGD) and Flame Ionization
More informationHigher Chemistry Principles to Production October Revision
igher Chemistry Principles to Production October Revision You should use your class notes, Evans2Chemweb and Scholar to help. Show your working for each question. Sections covered so far; Principles to
More informationChapter 5 Test. Directions: Write the correct letter on the blank before each question.
Chapter 5 Test Name: Date: Directions: Write the correct letter on the blank before each question. Objective 1: Explain the science of fire as it relates to energy, forms of ignition, and modes of combustion.
More informationOdor Detection and Analysis using GC/SAW znose
Complimentary Copy Odor Detection and Analysis using GC/SAW znose Edward J. Staples Electronic Sensor Technology 1077 Business Center Circle Newbury Park, California 91320 Ph. 1-805-480-1994 FAX 1-805-480-1984
More informationATOC 3500/CHEM 3151 Air Pollution Chemistry Lecture 1
ATOC 3500/CHEM 3151 Air Pollution Chemistry Lecture 1 Note Page numbers refer to Daniel Jacob s online textbook: http://acmg.seas.harvard.edu/publications/ jacobbook/index.html Atmos = vapor + sphaira
More informationDUST SETTLING USING A NEGATIVE IONIZATION SYSTEM
DUST SETTLING USING A NEGATIVE IONIZATION SYSTEM Dust Settling using a Negative Ionization System in a Confinement Swine Building Akihiro Tanaka, Yuanhui Zhang SUMMARY Dust is one of the main contaminants
More informationI. CHEM. E. SYMPOSIUM SERIES NO. 68
ADIABATIC CALORIMETRY AND SIKAREX TECHNIQUE L. Hub* The suitability of adiabatic calorimetry for safety investigations, the specific requirements on the experimental set-up and the problems of correct
More informationSlide 1. Slide 2. Slide 3. Choosing and Using the Best Sensor Technologies for Marine Chemistry Applications
Slide 1 Choosing and Using the Best Sensor Technologies for Marine Chemistry Applications Bob Henderson, BS, MBA GFG Instrumentation Inc. Ann Arbor, MI Toll free: 800-959-0329 Mobile: 734-355-1291 E-mail:
More informationAn ion source performs the following two functions:
Ionization The Ion Source An ion source performs the following two functions: 1) converts sample atoms or molecules to ionized particles (ions) in the gas phase (sometimes the task of introducing the atoms
More informationInterpretation of Organic Spectra. Chem 4361/8361
Interpretation of Organic Spectra Chem 4361/8361 Characteristics of Common Spectrometric Methods H-1 C-13 MS IR/RAMAN UV-VIS ORD/CD X- RAY Radiation type RF RF Not relevant IR UV to visible UV to visible
More informationOzone in the Atmosphere
Ozone in the Atmosphere Why are we concerned with ozone? This simple molecule affects us in very important ways. It protects us, as well as all animals and plants on our planet, from the harm that ultraviolet
More informationTR ACE ORGANIC. lgcstandards.com/foodandenvironment
U S E O F S TA B L E I S OTO P E I NTE R N A L S TA N D A R D S F O R TR ACE ORGANIC A N A LY S I S lgcstandards.com/foodandenvironment dr.ehrenstorfer@lgcgroup.com This paper explains why stable isotope
More informationPRINCIPLES AND APPLICATION OF CHROMATOGRAPHY. Dr. P. Jayachandra Reddy Mpharm PhD Principal & professor KTPC
PRINCIPLES AND APPLICATION OF CHROMATOGRAPHY Dr. P. Jayachandra Reddy Mpharm PhD Principal & professor KTPC CHROMATOGRAPHY Laboratory technique for the Separation of mixtures Chroma -"color" and graphein
More informationDevelopment of VUV-SPI-TOFMS Instrument for the Detection of Polycyclic Aromatic Hydrocarbons
Technical Report UDC 547. 52 : 543. 51 Development of VUV-SPI-TOFMS Instrument for the Detection of Polycyclic Aromatic Hydrocarbons Norihiro TSUJI* Shunichi HAYASHI Tetsuya SUZUKI Abstract To develop
More informationFluctuation-Enhanced Sensing with Commercial Gas Sensors
Sensors & Transducers ISSN 1726-5479 2003 by IFSA http://www.sensorsportal.com Fluctuation-Enhanced Sensing with Commercial Gas Sensors Jose L. SOLIS, Gary SEETON, Yingfeng LI, and Laszlo B. KISH Department
More informationPrinciples of Gas- Chromatography (GC)
Principles of Gas- Chromatography (GC) Mohammed N. Sabir January 2017 10-Jan-17 1 GC is a chromatographic technique utilizes gas as the mobile phase which is usually an inert gas (Hydrogen, Helium, Nitrogen
More informationDevelopment of on-line and Field Dual TD-GC-FID/MS for Automatic and Continuous Volatile Organic Compounds (VOCs) Ambient Air and Odour Monitoring
A publication of CHEMICAL ENGINEERING TRANSACTIONS VOL. 68, 2018 Guest Editors: Selena Sironi, Laura Capelli Copyright 2018, AIDIC Servizi S.r.l. ISBN 978-88-95608-65-5; ISSN 2283-9216 The Italian Association
More informationNew Developments in Raman Spectroscopic Analysis
New Developments in Raman Spectroscopic Analysis Mike Kayat B&W Tek, Inc 19 Shea Way Newark, DE 19713 United States of America +1 302 368 7824 mikek@bwtek.com 1 Overview Raman spectroscopy is now an established
More informationGas Chromatography. A schematic diagram of a gas chromatograph
Gas Chromatography In gas liquid chromatography (GLC) partition of solutes occurs between a mobile gas phase (the "carrier gas") and a stationary liquid phase present in the column. The gas-phase concentration
More informationMeasurement Technique and its Application to Trace Components of Atmospheric Gas
F e a t u r e A r t i c l e Feature Article Measurement Technique and its Application to Trace Components of Atmospheric Gas Junji Kato From early on, HORIBA has been developing and adopting various measurement
More informationMay 16, The Atom (A Nitrogen Atom is Depicted Here)
The Atom (A Nitrogen Atom is Depicted Here) 1 Important points to remember about the atom: 1. Protons and neutrons are in the nucleus. 2. Electrons are distributed around the nucleus within well-defined
More informationUnit 1: Chemistry in Action
Unit 1: Chemistry in Action Intermediate 1 Chemistry Learning Outcomes Substances Elements Everything in the world is made from about 100 elements. Each element has a name and a symbol. Chemists have arranged
More informationA- Determination Of Boiling point B- Distillation
EXP. NO. 2 A- Determination Of Boiling point B- Distillation The boiling point of a liquid is the temperature at which its vapor pressure is equal to the surrounding atmospheric pressure. The normal boiling
More informationBalancing chemical reaction equations (stoichiometry)
Balancing chemical reaction equations (stoichiometry) This worksheet and all related files are licensed under the Creative Commons Attribution License, version 1.0. To view a copy of this license, visit
More informationGCSE Chemistry. Module C7 Further Chemistry: What you should know. Name: Science Group: Teacher:
GCSE Chemistry Module C7 Further Chemistry: What you should know Name: Science Group: Teacher: R.A.G. each of the statements to help focus your revision: R = Red: I don t know this A = Amber: I partly
More informationELECTROMAGNETIC WAVES ELECTROMAGNETIC SPECTRUM
VISUAL PHYSICS ONLINE MODULE 7 NATURE OF LIGHT ELECTROMAGNETIC WAVES ELECTROMAGNETIC SPECTRUM When white light passes through a prism, it spreads out into a rainbow of colours, with red at one end and
More informationMARIYA INTERNATIONAL SCHOOL. Work sheet III. Term I. Level 8 Chemistry [MCQ] Name: CHEMICAL REACTIONS & SULFUR
MARIYA INTERNATIONAL SCHOOL Work sheet III Term I Level 8 Chemistry [MCQ] Name: CHEMICAL REACTIONS & SULFUR 1. A steel works and a chemical works are built near to a city. The limestone buildings in the
More informationChapter Eight: Conclusions and Future Work
2004 PhD Thesis 202 Chapter Eight: Conclusions and Future Work 8.1 Conclusions The Aerodyne aerosol mass spectrometer is capable of providing quantitative information on the chemical composition of the
More information20.2 Ion Sources. ions electrospray uses evaporation of a charged liquid stream to transfer high molecular mass compounds into the gas phase as MH n
20.2 Ion Sources electron ionization produces an M + ion and extensive fragmentation chemical ionization produces an M +, MH +, M +, or M - ion with minimal fragmentation MALDI uses laser ablation to transfer
More informationANALYSIS of gas atmospheres can be carried out by
316 IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, VOL. 47, NO. 1, FEBRUARY 1998 Gas Identification with Tin Oxide Sensor Array and Self-Organizing Maps: Adaptive Correction of Sensor Drifts Santiago
More informationChemistry Instrumental Analysis Lecture 34. Chem 4631
Chemistry 4631 Instrumental Analysis Lecture 34 From molecular to elemental analysis there are three major techniques used for elemental analysis: Optical spectrometry Mass spectrometry X-ray spectrometry
More informationThe Claviature of Gas Analysis
The Claviature of Gas Analysis Mass spectrometric gas analysis for quality assurance of gases and gas mixtures High purity and special gases are becoming increasingly important in the development of modern
More informationDevelopment of a Simple Cataluminescence Sensor System for Detecting and Discriminating Volatile Organic Compounds at Different Concentrations
pubs.acs.org/ac Development of a Simple Cataluminescence Sensor System for Detecting and Discriminating Volatile Organic Compounds at Different Concentrations Runkun Zhang, Xiaoan Cao,* Yonghui Liu, and
More information