SIFT-MS SELECTED ION FLOW TUBE MASS SPECTROMETRY TECHNOLOGY OVERVIEW

Size: px
Start display at page:

Download "SIFT-MS SELECTED ION FLOW TUBE MASS SPECTROMETRY TECHNOLOGY OVERVIEW"

Transcription

1 SIFT-MS SELECTED ION FLOW TUBE MASS SPECTROMETRY TECHNOLOGY OVERVIEW

2 NEXT GENERATION MASS SPECTROMETRY CONTENTS: 3 How SIFT-MS works 4 Soft chemical ionisation 5 Quantification in real-time 6 Utilising multiple precursor ions 7 Discriminate isobaric compounds and isomers in real-time In this guide we ve pulled together the essential concepts and principles of SIFT-MS. We have produced the guide specifically to give you an introduction to the technology behind our leading-edge SIFT-MS solutions. Of course we have a lot more information on how SIFT-MS and our products operate and deliver market-leading solutions. If you would like to know more or have any questions, we invite you to contact us or visit our website at You ll find our contact details on the back of this guide. Whether you need a turnkey solution or a leading-edge analytical instrument with proven flexibility, Syft Technologies has the technology and experience you re looking for. 2

3 HOW SIFT-MS WORKS NEXT GENERATION MASS SPECTROMETRY: IDENTIFY COMPOUNDS IN REAL-TIME QUANTIFY COMPOUNDS IN REAL-TIME SENSITIVITY AS LOW AS PPTV PUSH-BUTTON SIMPLICITY CONTINUOUS OR BATCH SAMPLING REAL RESULTS IN REAL-TIME SIFT-MS (Selected Ion Flow Tube Mass Spectrometry) uses chemical ionisation to analyse volatile compounds, either from whole-air samples or concentration media such as sorbent tubes. By combining gas-phase ion chemistry and tightly controlled reaction conditions, SIFT-MS has the unique ability to provide absolute concentrations for analytes, in real-time. Analytes can generally be detected and quantified within the 1 to 24 Da mass range, although this range is increasing with advances in the field. 5 4 THE SIFT-MS PROCESS CAN BE DIVIDED INTO FIVE MAIN STEPS. 1. Generation of ions Syft Technologies SIFT-MS instruments use either a microwave discharge or radio frequency (RF) source to generate positive ions. 2. Ion selection The ions enter an upstream chamber where a quadrupole mass filter removes all but the preferred precursor ions. Generally H 3 O +, NO + + and O 2 are selected as precursor ions. 3. Sample introduction and reaction The precursor ions pass through a venturi to a reaction chamber the flow tube where they react with sample, which enters the flow tube at a precisely controlled rate. 4. Selection of reaction products The reaction products enter a downstream chamber where they are filtered by a second quadrupole mass filter. 5. Detection A particle multiplier detects and counts the selected products. The use of thermalised ions combined with a good understanding of flow tube dynamics, well documented ion chemistry, dual quadrupoles and automated database matching systems, allows SIFT-MS to deliver real-time absolute quantification, without chromatographic separation or elaborate sample preparation

4 SOFT CHEMICAL IONISATION THE PRIMARY ADVANTAGES OF SOFT CHEMICAL IONISATION: Less analyte fragmentation, which yields simplified spectra, meaning lower interference and more accurate results No need for chromatographic columns, meaning lower running costs, real-time analysis and more analyses per hour Not all forms of ionisation are equal As with all mass spectrometry, SIFT-MS uses ionisation in the analysis process. But unlike many older forms of mass spectrometry, such as GC-MS, SIFT-MS uses relatively soft chemical ionisation. Electron Impact Ionisation SIFT-MS uses chemical ionisation because it minimises the fragmentation issues associated with harsher forms of ionisation (such as electron impact ionisation). Fragmentation occurs when harsh ionisation processes create fragment masses of the compounds that are being analysed. These fragments lead to complicated mass spectra with overlapping peaks, which make costly and time-consuming chromatographic separation necessary. SIFT-MS Soft Chemical Ionisation In contrast to harsh ionisation methods, the relatively soft chemical ionisation process used by SIFT-MS produces a significantly cleaner mass spectrum, minimising interference issues. This cleaner mass profile and reduced interference yields high accuracy and resolution without costly and timeconsuming chromatographic columns. THE RESULT The chemical ionisation used by SIFT-MS allows quick high-resolution analysis, without chromatographic columns and their associated sample preparation, costs and delays. An example The following two spectra are analyses of the common pollutant ethylbenzene. The first analysis (Figure 1) used electron impact ionisation and shows characteristic interference-generating fragmentation. The second analysis (Figure 2) used chemical ionisation with H 3 O + and shows a typically clean SIFT-MS spectrum with ethylbenzene at mass 17. Intensity/counts per second Intensity/counts per second Figure 1. Electron impact ionisation analysis of ethylbenzene Figure 2. Chemical ionisation H 3 O + analysis of ethylbenzene

5 QUANTIFICATION IN REAL-TIME THE PRIMARY ADVANTAGES OF REAL-TIME QUANTIFICATION: See which compounds are present and their absolute concentrations (not just their relative concentrations), in real-time See processes and reactions dynamically, as they happen Run more analyses per hour, instead of waiting for results What is quantitative analysis? Quantitative analysis determines the concentrations of analytes. The concentrations can be relative (where the concentration of an analyte is presented as a percentage of all analytes present) or absolute (where the true concentration is determined). Qualitative analysis (as opposed to quantitative analysis) simply identifies the presence or absence of an analyte, perhaps with a rough estimation of concentration. SIFT-MS provides absolute quantitative analysis in real-time, unlike other methods that also use chemical ionisation. How is real-time quantitative analysis possible? Gas-phase ion chemistry allows absolute quantitative analysis of trace gases, provided the host instrument s reaction chamber conditions are precisely controlled. SIFT-MS is the only mass spectrometry technology that provides this level of control, offering an unprecedented ability to detect trace compounds and quantify them absolutely in real-time. This high degree of control is obtained by: (i) introducing thermalised precursor ions into the reaction chamber (the flow tube) (ii) understanding the physical dynamics of the flow tube, including the reaction time (iii) having a comprehensive knowledge of the ion chemistry occurring in the flow tube for each analyte. As with all analytical techniques, SIFT-MS uses a type of pattern matching database to identify analytes. This database holds information on how rapidly an analyte reacts with the precursor ion (the rate coefficient for the reaction), the products of the reaction and their relative abundances. The SIFT-MS database is unique in that it identifies analytes and provides the means by which they are quantified, in real-time. The database is accessed directly and seamlessly from the instrument s control software. THE RESULT With its instantaneous and absolute determinations of concentrations, SIFT-MS is an ideal on-line or continuous process analysis tool for gas and headspace sampling. Its rapid sampling capability also makes SIFT-MS a valuable addition to busy commercial laboratory lineups. 5

6 UTILISING MULTIPLE PRECURSOR IONS THE PRIMARY ADVANTAGES OF MULTIPLE PRECURSOR IONS: See more analytes in your samples, even those that don t react with an individual precursor or react poorly Discriminate isobaric compounds and isomers Enhanced compound resolution over single precursor techniques such as PTR-MS and ACPI-MS. What s a precursor ion? A precursor ion is an ion used to chemically ionise a sample during an analysis process. SIFT-MS uses multiple precursor ions to extend the range of compounds that can be analysed, while less sophisticated methods use a single precursor ion. Single Precursor Scans Methods that use a single precursor ion are limited to seeing those analytes that react with the precursor to form products with a unique mass. If the reaction is poor or forms isobaric compounds or isomers, accurate results for the analyte cannot be reported. Figure 1 shows a typical result for a proton transfer reaction mass spectrometry (PTR-MS) scan of industrial combustion products. PTR-MS uses the single precursor ion H 3 O +. Significant compounds identified in the H 3 O + spectrum include: methanol (m/z = 33, 51, 69), acetaldehyde (m/z = 45, 63, 81), ethanol (m/z = 47, 65, 83), acetone and propanal (m/z = 59, 77), and benzene (m/z = 79). Counts/second Multiple Precursor Scans A SIFT-MS scan, which can apply multiple precursor ions (in this example H 3 O +, NO + and O 2+ ), produces the H 3 O + spectrum plus these spectra: Counts/second NO+ m/z NO + Precursor Scan Results The NO + precursor identifies propanal (m/z = 57), formamide (m/z = 75), and acetone (m/z = 88), plus confirms benzene (m/z = 78, 18) O2+ m/z O 2 + Precursor Scan Results The O 2 + precursor identifies ethylene (m/z = 28), nitrogen dioxide (NO2) (m/z = 46), and methane (m/z = 47). These additional compounds are not reported by methods that use H 3 O + as a single precursor ion. Counts/second 5 4 H3O m/z H 3 O + Precursor Scan Results THE RESULT SIFT-MS delivers more accurate identification and quantification of analytes, including isobaric compounds and isomers, and compounds that react poorly with any one precursor ion. 6

7 DISCRIMINATE ISOBARIC COMPOUNDS AND ISOMERS IN REAL-TIME THE PRIMARY ADVANTAGES OF REAL-TIME DISCRIMINATION: See individual analytes in your samples, not just summed totals for everything that happens to share a mass See isobaric compounds and many isomers in one seamless automated scan, with no need to run multiple scans or change columns Run more scans per hour The power of multiple precursor ions Analytes that share the same mass (isobaric compounds) or compounds that share the same mass and chemical formula (isomers) simply cannot be discriminated by methods that use only one precursor ion. Relative intensity (%) For example, proton transfer reaction mass spectrometry (PTR-MS), which uses H 3 O + as its sole precursor ion, cannot discriminate the common compounds acetaldehyde and ethylene oxide. Figure 1 shows a typical PTR-MS analysis spectrum for a sample that contained acetaldehyde and ethylene oxide. Figure 1. A PTR-MS H 3 O + analysis. Acetaldehyde and ethylene oxide share mass Acetaldehyde and ethylene oxide Relative intensity (%) Relative intensity (%) SIFT-MS, with a seamless application of H 3 O +, NO + and O 2 + precursor ions, adds these two spectra to the results: + Figure 2. A SIFT-MS O 2 analysis. An improvement but still not definitive. Acetaldehyde and ethylene oxide share mass 44, with acetaldehyde products also at mass Acetaldehyde and ethylene oxide Acetaldehyde Figure 3. Clear discrimination. A SIFT-MS NO + analysis with acetaldehyde at mass 43 and ethylene oxide at mass Acetaldehyde Ethylene oxide THE RESULT From one integrated scan process, SIFT-MS provides clear, real-time discrimination of isobaric compounds and many isomers. Now you can see individual compounds even if they are isobarics or isomers. 7

8 THE VOICE SERIES ONLY VOICE SERIES SIFT-MS INSTRUMENTS OFFER THIS COMBINATION OF ADVANTAGES: Real-time results ppb and ppt sensitivity High-accuracy, laboratory-grade results Instant and seamless switching between multiple precursor ions Discrimination of isobaric compounds and isomers Whole-air sampling (no sample preparation) Does not require chromatographic separation Direct analysis of high-moisture samples (such as breath) Push-button simplicity Full training and support programmes, worldwide Copyright 27 Syft Technologies Ltd BCR Syft Technologies Head Office 3 Craft Place, Middleton PO Box Christchurch, New Zealand Phone: +64 (3) Fax: +64 (3) Syft Technologies European Office Daresbury Innovation Centre, Suite F19 Daresbury, Cheshire WA4 4FS Phone: Fax: Global Contact Info@syft.com Website:

SIFT-MS. technology overview

SIFT-MS. technology overview SIFT-MS SELECTED ION FLOW TUBE MASS SPECTROMETRY technology overview contents 1. An overview of SIFT-MS 2. Principles of SIFT-MS a. Why chemical ionization? b. Why three reagent ions? c. How does SIFT-MS

More information

SIFT-MS SELECTED ION FLOW TUBE MASS SPECTROMETRY TECHNOLOGY OVERVIEW \ SYFT TECHNOLOGIES

SIFT-MS SELECTED ION FLOW TUBE MASS SPECTROMETRY TECHNOLOGY OVERVIEW \ SYFT TECHNOLOGIES SIFT-MS SELECTED ION FLOW TUBE MASS SPECTROMETRY TECHNOLOGY OVERVIEW \ SYFT TECHNOLOGIES CONTENTS 1. An overview of SIFT-MS 2. Principles of SIFT-MS a. Why chemical ionization? b. Why multiple reagent

More information

ULTRA-SENSITIVE SOLUTIONS FOR REAL-TIME TRACE GAS ANALYSIS

ULTRA-SENSITIVE SOLUTIONS FOR REAL-TIME TRACE GAS ANALYSIS ULTRA-SENSITIVE SOLUTIONS FOR REAL-TIME TRACE GAS ANALYSIS PRODUCT PORTFOLIO PROTON TRANSFER REACTION - MASS SPECTROMETRY SERIES PTR-QiToF LoD < 1 pptv Resolution > 5,500 m/ m (FWHM) The IONICON PTR-QiTOF

More information

VOC measurements in ambient air using Selected Ion Flow Tube Mass Spectrometry-automation and calibration considerations

VOC measurements in ambient air using Selected Ion Flow Tube Mass Spectrometry-automation and calibration considerations VOC measurements in ambient air using Selected Ion Flow Tube Mass Spectrometry-automation and calibration considerations Environmental Chemistry group, water Science Forum and the Separation Science Group

More information

SELECTED ION FLOW TUBE MASS SPECTROMETRY. Interscience Expert Center: VIP Meeting 15 Sept. 2009

SELECTED ION FLOW TUBE MASS SPECTROMETRY. Interscience Expert Center: VIP Meeting 15 Sept. 2009 SELECTED ION FLOW TUBE MASS SPECTROMETRY Interscience Expert Center: VIP Meeting 15 Sept. 2009 PROGRAM 14.00 u: The IS. X strategy 14.15 u: What exactly is SIFT-MS? 14.30 u: Developing methods on the Voice

More information

High-Speed Gas and Headspace Analysis for the Process-Line and Laboratory: SIFT- MS IFPAC 2017

High-Speed Gas and Headspace Analysis for the Process-Line and Laboratory: SIFT- MS IFPAC 2017 High-Speed Gas and Headspace Analysis for the Process-Line and Laboratory: SIFT- MS IFPAC 2017 Y.J. Mange D.B. Milligan V.S. Langford B.J. Prince M. Perkins C. Anderson T. Wilks Who is using Syft Technologies

More information

Analysis of TO-15/TO-17 air toxics in urban air using TD GC/TOF MS and automated compound identification software

Analysis of TO-15/TO-17 air toxics in urban air using TD GC/TOF MS and automated compound identification software Analysis of TO-15/TO-17 air toxics in urban air using TD GC/TOF MS and automated compound identification software NEMC, Washington D.C. August 6 th 2012 Nicola Watson Environmental Specialist Markes International

More information

Ion Trajectories in the Injection Quadrupole for SIFT-MS

Ion Trajectories in the Injection Quadrupole for SIFT-MS WDS' Proceedings of Contributed Papers, Part II, 44 48, 0. ISBN 978-80-7378-5- MATFYZPRESS Ion Trajectories in the Injection Quadrupole for SIFT-MS A. Spesyvyi Charles University Prague, Faculty of Mathematics

More information

Chemical Analysis. Low Level Oxygenates Analyzer. Trace Analysis of Oxygenates in Hydrocarbon Matrices. Gas Chromatography.

Chemical Analysis. Low Level Oxygenates Analyzer. Trace Analysis of Oxygenates in Hydrocarbon Matrices. Gas Chromatography. Chemical Analysis Low Level Oxygenates Analyzer Trace Analysis of Oxygenates in Hydrocarbon Matrices think forward Gas Chromatography The determination of sub to high ppm levels of ethers, alcohols, aldehydes

More information

The Claviature of Gas Analysis

The Claviature of Gas Analysis The Claviature of Gas Analysis Mass spectrometric gas analysis for quality assurance of gases and gas mixtures High purity and special gases are becoming increasingly important in the development of modern

More information

Agilent s New 8800 ICP-QQQ. Transforming ICP-MS Technology

Agilent s New 8800 ICP-QQQ. Transforming ICP-MS Technology Agilent s New 8800 ICP-QQQ Transforming ICP-MS Technology 1 8800 ICP-QQQ Key Product Hardware High matrix introduction (HMI) technology Dual conical Extraction and Omega lens focuses ions across the mass

More information

TOMAHAQ Method Construction

TOMAHAQ Method Construction TOMAHAQ Method Construction Triggered by offset mass accurate-mass high-resolution accurate quantitation (TOMAHAQ) can be performed in the standard method editor of the instrument, without modifications

More information

BEE-TEX Field Study. Aerodyne Mobile Laboratory May Berk Knighton (PTRMS) Tara Yacovitch, Rob Roscioli, John Nowak (QCL) Cody Floerchinger (EE)

BEE-TEX Field Study. Aerodyne Mobile Laboratory May Berk Knighton (PTRMS) Tara Yacovitch, Rob Roscioli, John Nowak (QCL) Cody Floerchinger (EE) BEE-TEX Field Study Aerodyne Mobile Laboratory May- 2014 Berk Knighton (PTRMS) Tara Yacovitch, Rob Roscioli, John Nowak (QCL) Cody Floerchinger (EE) BEETEX BEE-TEX Given the monitoring and modeling technologies

More information

ICP-MS. High Resolution ICP-MS.

ICP-MS. High Resolution ICP-MS. ICP-MS attom ES High Resolution ICP-MS www.nu-ins.com Attom ES Enhanced Sensitivity Enhanced Speed Enhanced Selectivity Enhanced Software The Attom ES from Nu Instruments is a double focussing inductively

More information

Hiden HPR60 Molecular Beam Mass Spectrometer System

Hiden HPR60 Molecular Beam Mass Spectrometer System Hiden HPR60 Molecular Beam Mass Spectrometer System vacuum analysis surface science plasma diagnostics gas analysis HPR60 MBMS Overview The Hiden HPR60 Molecular Beam Mass Spectrometer (MBMS) is a compact,

More information

Recent Results in the Development of Selected Ion Mobility Mass Spectrometry, SIM-MS, Technique

Recent Results in the Development of Selected Ion Mobility Mass Spectrometry, SIM-MS, Technique WDS'14 Proceedings of Contributed Papers Physics, 8 85, 14. ISBN 978-8-7378-76-4 MATFYZPRESS Recent Results in the Development of Selected Ion Mobility Mass Spectrometry, SIM-MS, Technique A. Spesyvyi

More information

Overview. Introduction. André Schreiber AB SCIEX Concord, Ontario (Canada)

Overview. Introduction. André Schreiber AB SCIEX Concord, Ontario (Canada) Quantitation and Identification of Pharmaceuticals and Personal Care Products (PPCP) in Environmental Samples using Advanced TripleTOF MS/MS Technology André Schreiber AB SCIEX Concord, Ontario (Canada)

More information

Multi-residue analysis of pesticides by GC-HRMS

Multi-residue analysis of pesticides by GC-HRMS An Executive Summary Multi-residue analysis of pesticides by GC-HRMS Dr. Hans Mol is senior scientist at RIKILT- Wageningen UR Introduction Regulatory authorities throughout the world set and enforce strict

More information

Characterisation of allergens in cosmetics by GC GC TOF MS with Select-eV variable-energy electron ionisation

Characterisation of allergens in cosmetics by GC GC TOF MS with Select-eV variable-energy electron ionisation Application Released: January 214 Application Note 522 Characterisation of allergens in cosmetics by GC GC TF MS with Select-eV variable-energy electron ionisation Summary This Application Note shows that

More information

Application Note 12: Fully Automated Compound Screening and Verification Using Spinsolve and MestReNova

Application Note 12: Fully Automated Compound Screening and Verification Using Spinsolve and MestReNova Application Note : Fully Automated Compound Screening and Verification Using Spinsolve and MestReNova Paul Bowyer, Magritek, Inc. and Mark Dixon, Mestrelab Sample screening to verify the identity or integrity

More information

Introduction to the Q Trap LC/MS/MS System

Introduction to the Q Trap LC/MS/MS System www.ietltd.com Proudly serving laboratories worldwide since 1979 CALL +1.847.913.0777 for Refurbished & Certified Lab Equipment ABI Q Trap LC/MS/MS Introduction to the Q Trap LC/MS/MS System The Q Trap

More information

MassHunter Software Overview

MassHunter Software Overview MassHunter Software Overview 1 Qualitative Analysis Workflows Workflows in Qualitative Analysis allow the user to only see and work with the areas and dialog boxes they need for their specific tasks A

More information

Prima PRO Process Mass Spectrometer

Prima PRO Process Mass Spectrometer APPLICATION NOTE Prima PRO Process Mass Spectrometer No. xxxx Controlling emissions by multi-component analysis of Volatile Organic Compounds (VOC) Authors: Peter Traynor, Thermo Fisher Scientific, Franklin,

More information

HYPHENATED TECHNOLOGY GUIDE

HYPHENATED TECHNOLOGY GUIDE HYPHENATED TECHNOLOGY GUIDE TABLE OF CONTENTS TG-IR...3 Hiden Analytical MS Systems for TG-MS...4 TG-MS...5 TG-GC/MS...6 TG-IR-GC/MS...8 HYPHENATED TECHNOLOGY GUIDE Coupling, or hyphenating, two instruments

More information

Technical know-how in thermal analysis measurement

Technical know-how in thermal analysis measurement Technical articles Technical know-how in thermal analysis measurement Evolved gas analysis by thermogravimetry-differential thermal analysis-mass spectrometry (TG-DTA-MS) technique Kazuko Motomura* and

More information

Catalysis CAPABILITIES

Catalysis   CAPABILITIES Catalysis www.extrel.com CAPABILITIES Contents Extrel instruments have been recognized for their exceptional performance by the world s leading researchers for more than 50 years. Reliability and flexibility

More information

Analysis of Polar Metabolites using Mass Spectrometry

Analysis of Polar Metabolites using Mass Spectrometry Analysis of Polar Metabolites using Mass Spectrometry TransMed Course: Basics in Clinical Proteomics and Metabolomics. Oct 10-19, 2012 dd.mm.yyyy Vidya Velagapudi, Ph.D, Adjunct Professor Head of the Metabolomics

More information

Fast, Quantitative Analysis of Residual Solvents in Cannabis Concentrates

Fast, Quantitative Analysis of Residual Solvents in Cannabis Concentrates APPLICATION NOTE Gas Chromatography/ Mass Spectrometry Authors: Lee Marotta Tom Kwoka David Scott Miles Snow Toby Astill PerkinElmer, Inc. Shelton, CT Fast, Quantitative Analysis of Residual Solvents in

More information

Supporting Information

Supporting Information Supporting Information KINETICS AND PRODUCT FORMATION DURING THE PHOTOOXIDATION OF BUTANOL ON ATMOSPHERIC MINERAL DUST Milena Ponczek and Christian George* Univ Lyon, Université Claude Bernard Lyon 1,

More information

TR ACE ORGANIC. lgcstandards.com/foodandenvironment

TR ACE ORGANIC. lgcstandards.com/foodandenvironment U S E O F S TA B L E I S OTO P E I NTE R N A L S TA N D A R D S F O R TR ACE ORGANIC A N A LY S I S lgcstandards.com/foodandenvironment dr.ehrenstorfer@lgcgroup.com This paper explains why stable isotope

More information

HYPHENATED TECHNOLOGY GUIDE

HYPHENATED TECHNOLOGY GUIDE HYPHENATED TECHNOLOGY GUIDE TABLE OF CONTENTS TG-IR...3 Hiden Analytical MS Systems for TG-MS...4 TG-MS...5 TG-GC/MS...6 TG-IR-GC/MS...8 HYPHENATED TECHNOLOGY GUIDE Coupling, or hyphenating, two instruments

More information

All Ions MS/MS: Targeted Screening and Quantitation Using Agilent TOF and Q-TOF LC/MS Systems

All Ions MS/MS: Targeted Screening and Quantitation Using Agilent TOF and Q-TOF LC/MS Systems All Ions MS/MS: Targeted Screening and Quantitation Using Agilent TOF and Q-TOF LC/MS Systems Technical Overview Introduction All Ions MS/MS is a technique that is available for Agilent high resolution

More information

Thermo Finnigan LTQ. Specifications

Thermo Finnigan LTQ. Specifications IET International Equipment Trading Ltd. www.ietltd.com Proudly serving laboratories worldwide since 1979 CALL +847.913.0777 for Refurbished & Certified Lab Equipment Thermo Finnigan LTQ Specifications

More information

Increasing Speed of UHPLC-MS Analysis Using Single-stage Orbitrap Mass Spectrometer

Increasing Speed of UHPLC-MS Analysis Using Single-stage Orbitrap Mass Spectrometer Increasing Speed of UHPLC-MS Analysis Using Single-stage Orbitrap Mass Spectrometer Olaf Scheibner and Maciej Bromirski Thermo Fisher Scientific, Bremen, Germany Overview Purpose: Improve the performance

More information

RS DYNAMICS ECOPROBE 5. Portable IR/PID Gas Analyzer PID. PID and IR Analyzers

RS DYNAMICS ECOPROBE 5. Portable IR/PID Gas Analyzer PID. PID and IR Analyzers RS DYNAMICS ECOPROBE 5 Portable IR/PID Gas Analyzer PID + IR PID and IR Analyzers General ECOPROBE 5 has two autonomous analyzers in one case. The combination of analyzers provides a set of data designed

More information

Introduction to GC/MS

Introduction to GC/MS Why Mass Spectrometry? Introduction to GC/MS A powerful analytical technique used to: 1.Identify unknown compounds 2. Quantify known materials down to trace levels 3. Elucidate the structure of molecules

More information

An ion source performs the following two functions:

An ion source performs the following two functions: Ionization The Ion Source An ion source performs the following two functions: 1) converts sample atoms or molecules to ionized particles (ions) in the gas phase (sometimes the task of introducing the atoms

More information

Chapter Eight: Conclusions and Future Work

Chapter Eight: Conclusions and Future Work 2004 PhD Thesis 202 Chapter Eight: Conclusions and Future Work 8.1 Conclusions The Aerodyne aerosol mass spectrometer is capable of providing quantitative information on the chemical composition of the

More information

INDUCTIVELY COUPLED PLASMA MASS SPECTROMETRY

INDUCTIVELY COUPLED PLASMA MASS SPECTROMETRY INDUCTIVELY COUPLED PLASMA MASS SPECTROMETRY Edited by AKBAR MONTASER George Washington University Washington, D.C. 20052, USA WILEY-VCH New York Chichester Weinheim Brisbane Singapore Toronto CONTENTS

More information

The ultratrace determination of iodine 129 in aqueous samples using the 7700x ICP-MS with oxygen reaction mode

The ultratrace determination of iodine 129 in aqueous samples using the 7700x ICP-MS with oxygen reaction mode The ultratrace determination of iodine in aqueous samples using the 7700x ICP-MS with oxygen reaction mode Application note Nuclear Authors Kazumi Nakano, Yasuyuki Shikamori, Naoki Sugiyama and Shinichiro

More information

Atmospheric Analysis Gases. Sampling and analysis of gaseous compounds

Atmospheric Analysis Gases. Sampling and analysis of gaseous compounds Atmospheric Analysis Gases Sampling and analysis of gaseous compounds Introduction - External environment (ambient air) ; global warming, acid rain, introduction of pollutants, etc - Internal environment

More information

SUPPORTING INFORMATION Antimicrobial activity of chlorinated amino acids and peptides

SUPPORTING INFORMATION Antimicrobial activity of chlorinated amino acids and peptides SUPPORTING INFORMATION Antimicrobial activity of chlorinated amino acids and peptides Melanie S. A. Coker*, Wan-Ping Hu, Senti T Senthilmohan and Anthony J. Kettle Free Radical Research Group, University

More information

Defining quality standards for the analysis of solid samples

Defining quality standards for the analysis of solid samples Defining quality standards for the analysis of solid samples Thermo Scientific Element GD Plus Glow Discharge Mass Spectrometer Redefine your quality standards for the elemental analysis of solid samples

More information

Application Note. Authors. Abstract. Introduction. Environmental

Application Note. Authors. Abstract. Introduction. Environmental Using a Chlorine Filter for Accurate-Mass Data Analysis of Environmental Samples Application Note Environmental Authors Imma Ferrer and E. Michael Thurman Center for Environmental Mass Spectrometry University

More information

MM 2. Innovation with Integrity. The new Generation of Mobile Mass Spectrometers. Defence CBRNE

MM 2. Innovation with Integrity. The new Generation of Mobile Mass Spectrometers. Defence CBRNE MM 2 The new Generation of Mobile Mass Spectrometers Innovation with Integrity Defence CBRNE Picture by: MOWAG GmbH Mobile CWA Detection and Identification Low weight and high performance detector Introducing

More information

Powerful Scan Modes of QTRAP System Technology

Powerful Scan Modes of QTRAP System Technology Powerful Scan Modes of QTRAP System Technology Unique Hybrid Triple Quadrupole Linear Ion Trap Technology Provides Powerful Workflows to Answer Complex Questions with No Compromises While there are many

More information

Instrumental Analysis. Mass Spectrometry. Lecturer:! Somsak Sirichai

Instrumental Analysis. Mass Spectrometry. Lecturer:! Somsak Sirichai 303351 Instrumental Analysis Mass Spectrometry Lecturer:! Somsak Sirichai Mass Spectrometry What is Mass spectrometry (MS)? An analytic method that employs ionization and mass analysis of compounds in

More information

Application note. Trace level analysis of sulfur, phosphorus, silicon and chlorine in NMP using the Agilent 8800 Triple Quadrupole ICP-MS

Application note. Trace level analysis of sulfur, phosphorus, silicon and chlorine in NMP using the Agilent 8800 Triple Quadrupole ICP-MS Trace level analysis of sulfur, phosphorus, silicon and chlorine in NMP using the Agilent 8800 Triple Quadrupole ICP-MS Application note Semiconductor Author Naoki Sugiyama Agilent Technologies, Tokyo,

More information

The Analysis of Trace Contaminants in High Purity Ethylene and Propylene Using GC/MS. Application. Agilent Technologies/Wasson ECE Monomer Analyzer

The Analysis of Trace Contaminants in High Purity Ethylene and Propylene Using GC/MS. Application. Agilent Technologies/Wasson ECE Monomer Analyzer The Analysis of Trace Contaminants in High Purity Ethylene and Propylene Using GC/MS Agilent Technologies/Wasson ECE Monomer Analyzer Application Authors Fred Feyerherm 119 Forest Cove Dr. Kingwood, TX

More information

Measurement & Analytics Measurement made easy. MB3600-CH70 FT-NIR polyol analyzer Pre-calibrated for OH value determination

Measurement & Analytics Measurement made easy. MB3600-CH70 FT-NIR polyol analyzer Pre-calibrated for OH value determination Measurement & Analytics Measurement made easy MB3600-CH70 FT-NIR polyol analyzer Pre-calibrated for OH value determination Adapted for polyols and polyurethanes applications The MB3600-CH70 Polyol Analyzer

More information

Mass Spectrometry. Hyphenated Techniques GC-MS LC-MS and MS-MS

Mass Spectrometry. Hyphenated Techniques GC-MS LC-MS and MS-MS Mass Spectrometry Hyphenated Techniques GC-MS LC-MS and MS-MS Reasons for Using Chromatography with MS Mixture analysis by MS alone is difficult Fragmentation from ionization (EI or CI) Fragments from

More information

Live Webinar : How to be more Successful with your ACQUITY QDa Detector?

Live Webinar : How to be more Successful with your ACQUITY QDa Detector? Live Webinar : How to be more Successful with your ACQUITY QDa Detector? Q&A Transcript ---------------- Q - How do you generate multiple charges reproductively? A - If you use the same settings on the

More information

HPLC Winter Webinars Part 2: Sample Preparation for HPLC

HPLC Winter Webinars Part 2: Sample Preparation for HPLC HPLC Winter Webinars Part 2: Sample Preparation for HPLC Jon Bardsley, Application Chemist Thermo Fisher Scientific, Runcorn/UK The world leader in serving science What am I Going to Talk About? What do

More information

GC/MS Analysis Laboratory Report

GC/MS Analysis Laboratory Report Report No.: J-123456 Date: March 1, 2016 P.O. No.: PO 1234A GC/MS Analysis Laboratory Report Prepared for: Mr. Customer Name Company Name, Inc. 123 First St. Your City, State Prepared by: Bradley J. Cline

More information

vacuum analysis plasma diagnostics surface science gas analysis

vacuum analysis plasma diagnostics surface science gas analysis Hiden EQP Systems High Sensitivity Mass and Energy Analysers for Monitoring, Control and Characterisation of Ions, Neutrals and Radicals in Plasma. vacuum analysis surface science gas analysis plasma diagnostics

More information

TargetScreener. Innovation with Integrity. A Comprehensive Screening Solution for Forensic Toxicology UHR-TOF MS

TargetScreener. Innovation with Integrity. A Comprehensive Screening Solution for Forensic Toxicology UHR-TOF MS TargetScreener A Comprehensive Screening Solution for Forensic Toxicology Innovation with Integrity UHR-TOF MS TargetScreener Get the Complete Picture Forensic laboratories are frequently required to perform

More information

EGASUS. 4D GCxGC TOFMS. Delivering the Right Results

EGASUS. 4D GCxGC TOFMS. Delivering the Right Results P EGAU 4D GCxGC TFM Delivering the Right Results LEC s P EGAU 4D GCxGC-TFM The Ultimate Analytical Instrument Pioneering GCxGC technology, combined with the Pegasus TFM and ChromaTF software provides today

More information

Insights Into Atmospheric Organic Aerosols Using An Aerosol Mass Spectrometer

Insights Into Atmospheric Organic Aerosols Using An Aerosol Mass Spectrometer Insights Into Atmospheric Organic Aerosols Using An Aerosol Mass Spectrometer A thesis submitted to the University of Manchester Institute of Science and Technology for the degree of Doctor of Philosophy

More information

Agilent All Ions MS/MS

Agilent All Ions MS/MS Agilent All Ions MS/MS Workflow Overview A Determine fragment ions for LC/MS Quant method B Develop final Quant method Develop LC/MS Qualitative Analysis method Process data with Find by Formula Build

More information

Extrel is widely respected for the quality of mass spectrometer systems that are

Extrel is widely respected for the quality of mass spectrometer systems that are Extrel is widely respected for the quality of mass spectrometer systems that are available to the world's top research scientists. In response to increasing requests for complete turn-key systems built

More information

Relative Sensitivity RS Measurements of Gases

Relative Sensitivity RS Measurements of Gases Gas Analysis Relative Sensitivity RS Measurements of Gases Introduction This note describes the main factors that influence the relative sensitivity factor (RSF) of a mass spectrometer and describes how

More information

ESPRIT Feature. Innovation with Integrity. Particle detection and chemical classification EDS

ESPRIT Feature. Innovation with Integrity. Particle detection and chemical classification EDS ESPRIT Feature Particle detection and chemical classification Innovation with Integrity EDS Fast and Comprehensive Feature Analysis Based on the speed and accuracy of the QUANTAX EDS system with its powerful

More information

FTIR measurement of NH 3, HCN, SO 2, H 2 S and COS in pulverized lignite oxy-fuel flames Daniel Fleig, Stefan Hjärtstam and Daniel Kühnemuth

FTIR measurement of NH 3, HCN, SO 2, H 2 S and COS in pulverized lignite oxy-fuel flames Daniel Fleig, Stefan Hjärtstam and Daniel Kühnemuth FTIR measurement of NH 3, HCN, SO 2, H 2 S and COS in pulverized lignite oxy-fuel flames Daniel Fleig, Stefan Hjärtstam and Daniel Kühnemuth Abstract Nitrogen and sulphur compounds are investigated in

More information

Quantitative Analysis of Opioids Using a Triple-Quadrupole GC/MS/MS

Quantitative Analysis of Opioids Using a Triple-Quadrupole GC/MS/MS PO-CON1408E Quantitative Analysis of Opioids Using a Pittcon 2014 1090-8P Laura Chambers, Richard Whitney, Ph.D., Nicole M. Lock, Zhuangzhi Max Wang, Ph.D., Clifford M. Taylor; Shimadzu Scientific Instruments,

More information

Quadrupole Mass Spectrometry Concepts. Mass spectrometers for residual gas analysis: Intermediate Level Users Guide

Quadrupole Mass Spectrometry Concepts. Mass spectrometers for residual gas analysis: Intermediate Level Users Guide Quadrupole Mass Spectrometry Concepts Mass spectrometers for residual gas analysis: Intermediate Level Users Guide What does Residual Gas Analysis allow us to do? RGA is the examination of the molecular

More information

Experience the most powerful benchtop NMR spectrometer

Experience the most powerful benchtop NMR spectrometer Experience the most powerful benchtop NMR spectrometer Outstanding Features Highest field strength (80 MHz) Largest chemical shift spread Highest sensitivity Superb Resolution (0.5 Hz/20 Hz) Multi-nuclear

More information

Pulsar. Delivering NMR to your benchtop

Pulsar. Delivering NMR to your benchtop Pulsar NMR Delivering NMR to your benchtop Pulsar TM NMR for your laboratory The Pulsar TM NMR spectrometer from Oxford Instruments delivers affordable, high performance NMR spectroscopy into the laboratory

More information

Applying the Technology of the TurboMatrix 650 ATD to the Analysis of Liquid Accelerants in Arson Investigation

Applying the Technology of the TurboMatrix 650 ATD to the Analysis of Liquid Accelerants in Arson Investigation Applying the Technology of the TurboMatrix 650 ATD to the Analysis of Liquid Accelerants in Arson Investigation Introduction Fire investigation involves many different types of analyses from crime scene

More information

ANALYTICAL METHOD DETERMINATION OF VOLATILE ALDEHYDES IN AMBIENT AIR Page 1 of 11 Air sampling and analysis

ANALYTICAL METHOD DETERMINATION OF VOLATILE ALDEHYDES IN AMBIENT AIR Page 1 of 11 Air sampling and analysis DETERMINATION OF VOLATILE ALDEHYDES IN AMBIENT AIR Page 1 of 11 Replaces: Dated: Author: Date: AM-No.: New New Nils Arne Jentoft 18.06.2014 0 CHANGES This procedure is new. 1 SCOPE This document describes

More information

Confirmation of In Vitro Nefazodone Metabolites using the Superior Fragmentation of the QTRAP 5500 LC/MS/MS System

Confirmation of In Vitro Nefazodone Metabolites using the Superior Fragmentation of the QTRAP 5500 LC/MS/MS System Confirmation of In Vitro Nefazodone Metabolites using the Superior Fragmentation of the QTRAP 5500 LC/MS/MS System Claire Bramwell-German, Elliott Jones and Daniel Lebre AB SCIEX, Foster City, California

More information

CHAPTER D4 ORTHOGONAL TIME OF FLIGHT OPTICS

CHAPTER D4 ORTHOGONAL TIME OF FLIGHT OPTICS Back to Basics Section D: Ion Optics CHAPTER D4 ORTHOGONAL TIME OF FLIGHT OPTICS TABLE OF CONTENTS QuickGuide...413 Summary...415 Introduction...417 The physical basis of orthogonal TOF....... 419 Pulsedmainbeamsofions...421

More information

THE IMPLEMENTATION OF A SCREENING WORKFLOW FOR ION MOBILITY QUADRUOPOLE TIME-OF-FLIGHT MASS SPECTROMETRIC ANALYSIS OF PFOS ISOMERS

THE IMPLEMENTATION OF A SCREENING WORKFLOW FOR ION MOBILITY QUADRUOPOLE TIME-OF-FLIGHT MASS SPECTROMETRIC ANALYSIS OF PFOS ISOMERS THE IMPLEMENTATION O A SCREENING WORKLOW OR ION MOBILITY QUADRUOPOLE TIME-O-LIGHT MASS SPECTROMETRIC ANALYSIS O POS ISOMERS Ken Rosnack ken_rosnack@waters.com Ingrid Ericson Jogsten and Bert van Bavel

More information

M M e M M H M M H. Ion Sources

M M e M M H M M H. Ion Sources Ion Sources Overview of Various Ion Sources After introducing samples into a mass spectrometer, the next important step is the conversion of neutral molecules or compounds to gas phase ions. The ions could

More information

MassHunter TOF/QTOF Users Meeting

MassHunter TOF/QTOF Users Meeting MassHunter TOF/QTOF Users Meeting 1 Qualitative Analysis Workflows Workflows in Qualitative Analysis allow the user to only see and work with the areas and dialog boxes they need for their specific tasks

More information

Monomer Analysis. Analysis by Gas Chromatography WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results.

Monomer Analysis. Analysis by Gas Chromatography WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results. Monomer Analysis Analysis by Gas Chromatography Engineered Solutions, Guaranteed Results. WASSON - ECE INSTRUMENTATION Polymer Grade Monomer Analysis Monomer Analysis Impurities in feedstocks can adversely

More information

Finnigan LCQ Advantage MAX

Finnigan LCQ Advantage MAX www.ietltd.com Proudly serving laboratories worldwide since 1979 CALL +847.913.0777 for Refurbished & Certified Lab Equipment Finnigan LCQ Advantage MAX The Finnigan LCQ Advantage MAX ion trap mass spectrometer

More information

Application Note. Abstract. Introduction. Experimental-Instrument Conditions. By: Anne Jurek

Application Note. Abstract. Introduction. Experimental-Instrument Conditions. By: Anne Jurek Automated Handling Techniques for the Analysis of Elevated Volatile Organic Compound (VOC) Concentrations in Soils Utilizing the Atomx Concentrator/Multimatrix Autosampler. Application Note By: Anne Jurek

More information

Thermo Scientific ConFlo IV Universal Interface. Continuous Flow Interface. Isotope Ratio MS

Thermo Scientific ConFlo IV Universal Interface. Continuous Flow Interface. Isotope Ratio MS Thermo Scientific ConFlo IV Universal Interface Continuous Flow Interface Isotope Ratio MS 3 ConFlo IV Universal Interface for Continuous Flow Isotope Ratio MS The development of Continuous Flow carrier

More information

pinene (at 2 and 50 Torr) and β-pinene (at 200 Torr) with OH have been determined in varied conditions.

pinene (at 2 and 50 Torr) and β-pinene (at 200 Torr) with OH have been determined in varied conditions. ABSTRACT The composition of the troposphere is strongly affected by biogenic and anthropogenic emissions of chemical compounds, including hydrocarbons, carbon monoxide, and the nitrogen oxides. The emissions

More information

AppNote 2/2002. Discrimination of Soft Drinks using a Chemical Sensor and Principal Component Analysis KEYWORDS ABSTRACT

AppNote 2/2002. Discrimination of Soft Drinks using a Chemical Sensor and Principal Component Analysis KEYWORDS ABSTRACT ppnote 2/2002 Discrimination of Soft Drinks using a Chemical Sensor and Principal Component nalysis Vanessa Kinton, Edward Pfannkoch, Jacqueline Whitecavage Gerstel, Inc., 701 Digital Drive, Suite J, Linthicum,

More information

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment www.ietltd.com Proudly serving laboratories worldwide since 1979 CALL +1.847.913.0777 for Refurbished & Certified Lab Equipment Applied Biosystems QStar Pulsar i Features of the API QSTAR Pulsar i The

More information

2B Technologies, Inc. An InDevR Company

2B Technologies, Inc. An InDevR Company 2B Technologies, Inc. An InDevR Company Technical Note No. 40 UV-Absorbing Interferences in Ozone Monitors Date: 22 April 2015 Author: John Birks Background Ozone measurements by absorbance of the 253.7-nm

More information

Making Sense of Differences in LCMS Data: Integrated Tools

Making Sense of Differences in LCMS Data: Integrated Tools Making Sense of Differences in LCMS Data: Integrated Tools David A. Weil Agilent Technologies MassHunter Overview Page 1 March 2008 How Clean is our Water?... Page 2 Chemical Residue Analysis.... From

More information

Improved Throughput and Reproducibility for Targeted Protein Quantification Using a New High-Performance Triple Quadrupole Mass Spectrometer

Improved Throughput and Reproducibility for Targeted Protein Quantification Using a New High-Performance Triple Quadrupole Mass Spectrometer Improved Throughput and Reproducibility for Targeted Protein Quantification Using a New High-Performance Triple Quadrupole Mass Spectrometer Reiko Kiyonami, Mary Blackburn, Andreas FR Hühme: Thermo Fisher

More information

Balancing chemical reaction equations (stoichiometry)

Balancing chemical reaction equations (stoichiometry) Balancing chemical reaction equations (stoichiometry) This worksheet and all related files are licensed under the Creative Commons Attribution License, version 1.0. To view a copy of this license, visit

More information

Preparation of Food and Feed Samples for Metals Analysis

Preparation of Food and Feed Samples for Metals Analysis White Paper Preparation of Food and Feed Samples for Metals Analysis Alan Cross Technical Specialist, Metals Laboratory Preparation of Food and Feed Samples for Metals Analysis The relative virtues of

More information

TANDEM MASS SPECTROSCOPY

TANDEM MASS SPECTROSCOPY TANDEM MASS SPECTROSCOPY 1 MASS SPECTROMETER TYPES OF MASS SPECTROMETER PRINCIPLE TANDEM MASS SPECTROMETER INSTRUMENTATION QUADRAPOLE MASS ANALYZER TRIPLE QUADRAPOLE MASS ANALYZER TIME OF FLIGHT MASS ANALYSER

More information

Welcome! Course 7: Concepts for LC-MS

Welcome! Course 7: Concepts for LC-MS Welcome! Mass Spectrometry meets Cheminformatics Tobias Kind and Julie Leary UC Davis Course 7: Concepts for LC-MS Class website: CHE 241 - Spring 28 - CRN 16583 Slides: http://fiehnlab.ucdavis.edu/staff/kind/teaching/

More information

Environmental Air Monitoring by TD/GC-TOF MS with Variable Energy Ionization

Environmental Air Monitoring by TD/GC-TOF MS with Variable Energy Ionization Environmental Air Monitoring by TD/GC-TOF MS with Variable Energy Ionization Nicola Watson, Ph.D. Where we re going next in air? Monday 4 th August 2014 Challenges facing the Air market Market at rock

More information

HIGH PERFORMANCE MASS SPECTROMETERS FOR EARTH AND PLANETARY SCIENCE

HIGH PERFORMANCE MASS SPECTROMETERS FOR EARTH AND PLANETARY SCIENCE Nu Plasma II Multi-Collector ICP-MS Attom High Resolution ICP-MS Panorama HR Stable Isotope Ratio MS HIGH PERFORMANCE MASS SPECTROMETERS FOR EARTH AND PLANETARY SCIENCE PRODUCT BROCHURE Astrum Glow Discharge

More information

GAS CHROMATOGRAPHY MASS SPECTROMETRY. Pre-Lab Questions

GAS CHROMATOGRAPHY MASS SPECTROMETRY. Pre-Lab Questions GAS CHROMATOGRAPHY MASS SPECTROMETRY Pre-Lab Questions Questions to be answered before doing the experiment. The answers are due at the beginning of each experiment without exception (the questions are

More information

PesticideScreener. Innovation with Integrity. Comprehensive Pesticide Screening and Quantitation UHR-TOF MS

PesticideScreener. Innovation with Integrity. Comprehensive Pesticide Screening and Quantitation UHR-TOF MS PesticideScreener Comprehensive Pesticide Screening and Quantitation Innovation with Integrity UHR-TOF MS The Challenge of Comprehensive Pesticide Residue Analysis The use of pesticides to reduce crop

More information

New Approaches to the Development of GC/MS Selected Ion Monitoring Acquisition and Quantitation Methods Technique/Technology

New Approaches to the Development of GC/MS Selected Ion Monitoring Acquisition and Quantitation Methods Technique/Technology New Approaches to the Development of GC/MS Selected Ion Monitoring Acquisition and Quantitation Methods Technique/Technology Gas Chromatography/Mass Spectrometry Author Harry Prest 1601 California Avenue

More information

Application. Gas Chromatography February Introduction

Application. Gas Chromatography February Introduction Ambient Headspace Analysis with the Agilent 7683 Automatic Liquid Sampler Application Gas Chromatography February 1998 Authors Matthew S. Klee and Chin Kai Meng Agilent Technologies, Inc. 2850 Centerville

More information

UV Hound Series. Dependable High Quality Air Monitoring. Accurate Readings Within Seconds. Portable UVDOAS Multi-gas Analyzers. Multi-Gas Capability

UV Hound Series. Dependable High Quality Air Monitoring. Accurate Readings Within Seconds. Portable UVDOAS Multi-gas Analyzers. Multi-Gas Capability UV Hound Series Portable UVDOAS Multi-gas Analyzers Multi-Gas Capability Dependable High Quality Air Monitoring Individual VOCs PPB Sensitivity Non-Contact Optical Measurement Automated Reporting Configurable

More information

Polymer plants continue to seek ways to increase production and efficiency without compromising safety.

Polymer plants continue to seek ways to increase production and efficiency without compromising safety. Polyethylene Polypropylene APPLICATION NOTE NOTE Polymer plants continue to seek ways to increase production and efficiency without compromising safety. Process gas analysis is integral to the control

More information

Choosing the metabolomics platform

Choosing the metabolomics platform GBS 748 Choosing the metabolomics platform Stephen Barnes, PhD 4 7117; sbarnes@uab.edu So, I have my samples what s next? You ve collected your samples and you may have extracted them Protein precipitation

More information

Thermo Scientific LTQ Orbitrap Velos Hybrid FT Mass Spectrometer

Thermo Scientific LTQ Orbitrap Velos Hybrid FT Mass Spectrometer IET International Equipment Trading Ltd. www.ietltd.com Proudly serving laboratories worldwide since 1979 CALL +847.913.0777 for Refurbished & Certified Lab Equipment Thermo Scientific LTQ Orbitrap Velos

More information

ICP-MS. plasma 17OO. High Resolution Multi-Collector ICP-MS.

ICP-MS. plasma 17OO. High Resolution Multi-Collector ICP-MS. ICP-MS plasma 17OO High Resolution Multi-Collector ICP-MS www.nu-ins.com Plasma 1700 & Sapphire 1700 Plasma 1700: Large Geometry Multi-Collector Inductively Coupled Plasma Mass Spectrometer For more information

More information

GUIDELINES ON THE USE OF MASS SPECTROMETRY (MS) FOR IDENTIFICATION, CONFIRMATION AND QUANTITATIVE DETERMINATION OF RESIDUES CAC/GL

GUIDELINES ON THE USE OF MASS SPECTROMETRY (MS) FOR IDENTIFICATION, CONFIRMATION AND QUANTITATIVE DETERMINATION OF RESIDUES CAC/GL CAC/GL 56-2005 Page 1 of 6 GUIDELINES ON THE USE OF MASS SPECTROMETRY (MS) FOR IDENTIFICATION, CONFIRMATION AND QUANTITATIVE DETERMINATION OF RESIDUES CONFIRMATORY TESTS CAC/GL 56-2005 When analyses are

More information