PURCHASE OF LAB EQUIPMENTS FOR CHEMISTRY [Kindly enclose a signed copy of this document along with the TENDER Document]

Size: px
Start display at page:

Download "PURCHASE OF LAB EQUIPMENTS FOR CHEMISTRY [Kindly enclose a signed copy of this document along with the TENDER Document]"

Transcription

1 T.K.M. COLLEGE OF ARTS & SCIENCE KOLLAM, Kerala 6900, INDIA Tender No 20/FIST/ ITEMS PURCHASE OF LAB EQUIPMENTS FOR CHEMISTRY [Kindly enclose a signed copy of this document along with the TENDER Document]. Digital Magnetic Stirrer with Hotplate and temp. sensor-2 2. Digital Magnetic Stirrer with Hotplate-2 3. Electronic balance 4 digit- 4. Conductivity meter-2. Ultrasonic Bath- 6. ph meter- 7. Double distillation Unit- 8. Chromatographic Columns-Variable 9. UV lamp- 0. Silica Gel for Chromatographic Columns-. Thin Layer Chromatography kit- 2. UV Cabinet with dual UV Light- 3. Flash Chromatographic Columns-2 Contact Person for Technical Clarification Regarding Lab Equipments for Chemistry,. Dr. S. Anas, Assistant Professor, Department of Chemistry, anas.tkmchem@gmail.com, Mobile: Dr. Sumalekshmi, Assistant Professor, Department of Chemistry, sumees@gmail.com, Mobile: To purchase tender form, please contact T.K.M. College of Arts and Science office. The soft copy of TENDER FORMS can be obtained by contacting T.K.M.C.A.S. Office/ Dr. S. Anas. In such cases separate DD for the cost of Tender forms and EMD drawn in favor of The Principal, T.K.M. College of Arts and Science, Kollam payable at SBT Bank Karicode (Branch), Kollam, Kerala should be send along with the Tender Document (The DD cover should be send via. registered post or speed post separately). Cost of Tender Form: Rs 200+ Rs. 48 EMD: Rs. 6,00/- Last Date of Sale of Tender Forms: 26/2/20 02:00 pm Last Date of Submission of Tenders: 26/2/20 04:00 pm Date of Opening Tender: 0/0/206 0:00 am at Conference room, T.K.M. College of Arts & Science, Kollam.

2 EQUIPMENTS TO BE PURCHASED UNDER FIST GRANT Sl.No Equipment Specification Digital Magnetic Stirrer with Hotplate and temp. sensor-2 No. O Heating temperature range 0-00 C Stirring quantity max. (H 2O) 0 Litres Heat control accuracy 0 ±K Fixed safety circuit 0 C Heat control LED Motor rating input W Motor rating output. W Speed range rpm Stirring bar length max. 80 mm Heating rate ( l H 2O in H) K/min Set-up plate dimensions 80 x 80 mm Dimensions (W x H x D) 220 x 0 x 330 mm Voltage 230 / 20 / 00 V Frequency 0/60 Hz Power input 020 W 2 Digital Magnetic Stirrer with Hotplate-2 No. 3 Double distillation Unit & Accessories- Stirring quantity max. (H 2O)- Litres Motor rating input W Motor rating output. W Speed range rpm Heat output 20 W Heating rate ( l H 2O in H) 2. K/min Heating temperature range 0-00 C Heat control LED Heat control accuracy 0 ±K Fixed safety circuit 0 C Set-up plate material ceramic Set-up plate dimensions 00 x 00 mm Dimensions (Wx H x D) 0 x 0 x 260 mm Permissible ambient temperature - 40 C Permissible relative humidity 80 % Voltage 230 / 20 / 00 V Frequency 0/60 Hz Power input 270 W Distillation unit should be made up of borosil glass. Borosilicate boiler with water leveler & Condenser Quartz Heater Horizontal or vertical Type tubes Dist. Water output Capacity :4Lt/hr. Electrical Requirements : volts ph Conductivity S/cm < x 0-6

3 Distillation Apparatus Power Supply should be automatic, the water level should not falls below the coil. The sensor rods are adjusted above heater levels. It should give buzzer sound alert or any other type indication in low water level. 4 6 Conductivity meter-2 Electronic balance 4 digit P H meter with electrode (Digital) 7 Ultrasonic Bath- Micro Controller based Conductivity-TDS Meter with cells (.0CC & 0.CC) and Temp. Probe Selectable Ranges(for Conductivity): 0-20 micro /Mhos,200 micro/mhos, 2 milli/mhos & 200 milli/mhos Measuring Accuracy: ±% of F.S in all ranges ± count LED display Conductivity cells : Cell Constant 0. &.0 Power requirement : 230V ± 0%, 0Hz single phase Standard Accessories including Conductivity cells, temperature probe, Stand and Clamp. Capacity : 220g Readability : 0.000g (0.mg) Tare Range : 220g Repeatability : < ± 0.000g Linearity : ± g Pan Diameter : 90mm Dimensions : 340mm x 22mm x 340mm Minimum Sample Weight : 0mg LED display ph range 0 to 4.00 ph Repeatability ± 0.0 ph ± digit for ph 3 point calibration Resolution 0.00 ph, mv in mv mode Standardization range ± ph Millivolt range 0 to ±999 mv Temperature compensation -Auto Display : 3 /2- digit red LCD seven segment with automatic polarity and decimal point Polarization current :0 µa Recorder output : ± 0 mv/ ph in ph mode ± 0 mv/00 mv in mv mode Accessories: Combined electrode, Stand and clamp Tank Capacity : 2- Ltrs Ultrasonic Freq : 33 ± 7 KHz Ultrasonic Power effective: 30W, 60W Timer : Count down with digital display Input Supply : 230 V Cleaning tank made of cavitation-resistant material

4 Heater : With digital temperature controller. Tank Size: Approximate dimensions- 8" 4" 4". Tank internal dimensions -W / D / H (mm) 90 / 80 / 60 (minimum). Accessories: lid, basket and other items. No Chromatographic Columns-Variable Std pack size mm 00mm 00mm 4 Grey body / Grey collect and plunger 220 V Flask Chromatography Sprayers With Rubber Bulb No UV lamp Quantity Long wave (UV-A) and short wave (UV-C) complete with 2-watt white light bulb and ENF-280C lamp featuring 8-watt LW tube, 8-watt SW tube and filter assembly Dimension:.4L x 44.W x 24.8 cm H No Silica gel Quantity Silica gel mesh for column, chromatography

5 Thin Layer Chromatography kit. Consists Of Applicator, Constructed To Draw Thin Uniform Layer Variable Form 0 To 2 MM. 2. Minimum Thickness Attainable 0. MM. Accurate Design Of The Applicator Gives No Trouble In Coating Number Of Plates At A Time. 3.It Is Made Of Aluminium In Proper Shape Of Feeler Gauge 4. Are Supplied To Facilitate The Setting Of Applicator Supplied With Drawing Board, Drying Rack, Spotting Guide, Developing Chamber, Capillary, Silica Gel, Glass Plates. No Cabinet with dual UV Light Quantity Specifications: Cabinet Should be made of mild steel sheet with powder coating. Viewing TLC plate under UV light should be possible. No Flash-chromatography Quantity Repl. column for flash-chromatography 2 Flash. chromatography replacement column For any clarification regarding tendering process kindly contact, Dr. S. Anas Assistant Professor in Chemistry Convener DST FIST Project T.K.M. College of Arts & Science Karicode 6900, Kollam Kerala, India anas.tkm@gmail.com Mobile:

Introductory Remarks:

Introductory Remarks: Introductory Remarks: At all times while you are in the laboratory you should wear safety spectacles or own spectacles if they have been approved. Eating of any kind of food or drinking is strictly prohibited

More information

PLANNING EXPERIMENT (SECTION B)

PLANNING EXPERIMENT (SECTION B) SIMPLE PENDULUM OF Period depends on length of pendulum Length increase, period increase To investigate the relationship between period and length of pendulum MV : length of pendulum RV : period FV : angle

More information

THERMOCOUPLE CHARACTERISTICS TRAINER

THERMOCOUPLE CHARACTERISTICS TRAINER THERMOCOUPLE CHARACTERISTICS TRAINER (Model No : ) User Manual Version 2.0 Technical Clarification /Suggestion : / Technical Support Division, Vi Microsystems Pvt. Ltd., Plot No :75,Electronics Estate,

More information

INFRARED THERMOMETER Model : TM-959

INFRARED THERMOMETER Model : TM-959 LED target light, Emissivity adjustment INFRARED THERMOMETER Model : TM-959 Your purchase of this I N F R A R E D THERMOMETER marks a step forward for you into the field of precision measurement. Although

More information

EXPERIMENTAL SETUP AND PROCEDURE

EXPERIMENTAL SETUP AND PROCEDURE CHAPTER 3 EXPERIMENTAL SETUP AND PROCEDURE 3.1 Determination of vapour-liquid equilibria Isobaric Vapour-Liquid Equilibria date have been obtained, using a Smith and Bonner [39] type still which is a modified

More information

Basic Equipments and Instruments used in Chemistry laboratory: Balance: It is an instrument for measuring mass.

Basic Equipments and Instruments used in Chemistry laboratory: Balance: It is an instrument for measuring mass. Basic Equipments and Instruments used in Chemistry laboratory: Balance: It is an instrument for measuring mass. Pipettes: They are used to transfer of known volumes of liquids from one container to another.

More information

PG-200/PG-208 PRESSURE GAUGES P G G P P

PG-200/PG-208 PRESSURE GAUGES P G G P P Digital 3 1/2 digits monitor Set button for switch output HI or LO (PG-200) (PG-208) Digital 3 1/2 digits Power switch LO setting VR for switch output LO HI setting VR for switch output HI SPAN adjustment

More information

Experiment 1: The Borohydride Reduction of 9-Fluorenone to 9-Fluorenol

Experiment 1: The Borohydride Reduction of 9-Fluorenone to 9-Fluorenol Experiment 1: The Borohydride Reduction of 9-Fluorenone to 9-Fluorenol Background: In this week s experiment, a metal hydride will be used as a reducing agent. Metal hydrides can be quite reactive, and

More information

Automatic titrators, TitroMatic

Automatic titrators, TitroMatic 112 TitroMatic These are the fourth generation of CRISON titrators. CRISON has over 25 years experience in this field and knows that, for certain applications, the performance and cost of large titrator

More information

Compact ph Measuring Instruments With Pro Engineering

Compact ph Measuring Instruments With Pro Engineering testo 205, 206, 230 Compact ph Measuring Instruments With Pro Engineering With interchangeable measurement electrode ph C The new ph instruments with innovative probe engineering Measurement of the ph

More information

User s Guide. Waterproof Palm ph Meter Model PH220. Introduction

User s Guide. Waterproof Palm ph Meter Model PH220. Introduction User s Guide Waterproof Palm ph Meter Model PH220 Introduction Congratulations on your purchase of the Extech PH220 waterproof ph/mv meter. This microprocessor-based device with tactile buttons is battery

More information

INE-PHS-3E ph Meter Operating Manual

INE-PHS-3E ph Meter Operating Manual INE-PHS-3E ph Meter Operating Manual PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION Hagavish st. Israel 58817 Tel: 972 3 5595252, Fax: 972 3 5594529 mrc@mrclab.com MRC.12.16 ADVICE: Read this instruction

More information

Measuring Ammonia in Water and Wastewater using the Thermo Scientific Orion Dual Star ph/ise Meter

Measuring Ammonia in Water and Wastewater using the Thermo Scientific Orion Dual Star ph/ise Meter Measuring Ammonia in Water and Wastewater using the Thermo Scientific Orion Dual Star ph/ise Meter Water and Lab Products, Thermo Fisher Scientific Technical Note 505 Key Words Thermo Scientific Orion

More information

Experiment A. Introduction to the Organic Laboratory and Characterization Techniques

Experiment A. Introduction to the Organic Laboratory and Characterization Techniques Experiment A. Introduction to the Organic Laboratory and Characterization Techniques 1. EXPERIMENTAL OBJECTIVES: a. To identify the safety features and physical layout of the organic laboratory. b. To

More information

1 Fig. 3.1 shows the variation of the magnetic flux linkage with time t for a small generator. magnetic. flux linkage / Wb-turns 1.

1 Fig. 3.1 shows the variation of the magnetic flux linkage with time t for a small generator. magnetic. flux linkage / Wb-turns 1. 1 Fig. 3.1 shows the variation of the magnetic flux linkage with time t for a small generator. 2 magnetic 1 flux linkage / 0 10 2 Wb-turns 1 2 5 10 15 t / 10 3 s Fig. 3.1 The generator has a flat coil

More information

Electrochemistry. Conductivity of strong and weak electrolytes LEC 06. What you need: What you can learn about. Principle and tasks

Electrochemistry. Conductivity of strong and weak electrolytes LEC 06. What you need: What you can learn about. Principle and tasks LEC 06 Electrochemistry What you can learn about Kohlrausch s law Equivalent conductivity Temperature-dependence of conductivity Ostwald s dilution law Principle and tasks It is possible to differentiate

More information

SECTION 1 - WHAT IS A BTU METER? BTU's = Flow x ΔT Any ISTEC BTU Meter System consists of the following main components:

SECTION 1 - WHAT IS A BTU METER? BTU's = Flow x ΔT Any ISTEC BTU Meter System consists of the following main components: SECTION 1 - WHAT IS A BTU METER? ISTEC BTU Meters measure energy usage by multiplying flow rate and temperature difference. As the water (or other liquid) passes through these lines, the multi-wing turbine

More information

PG-100 HANDY MANOMETER COPAL ELECTRONICS FEATURES MODEL NUMBER DESIGNATION P G G P. marking Compatible with EMC directive

PG-100 HANDY MANOMETER COPAL ELECTRONICS FEATURES MODEL NUMBER DESIGNATION P G G P. marking Compatible with EMC directive HANDY MANOMETER Power button Hold button marking Compatible with EMC directive Digital 3 1/2 digits Zero adjustment VR FEATURES Excellent stability State of the art sensor and circuit technology guarantees

More information

IDENTIFICATION AND DETERMINATION OF HYDROQUINONE IN COSMETIC PRODUCTS 2 14/11/17 ACM 003 BY TLC AND HPLC

IDENTIFICATION AND DETERMINATION OF HYDROQUINONE IN COSMETIC PRODUCTS 2 14/11/17 ACM 003 BY TLC AND HPLC A. IDENTIFICATION BY TLC 1. SCOPE AND FIELD OF APPLICATION The method describes the identification of hydroquinone in cosmetic products. 2. PRINCIPLE Hydroquinone is identified by thin layer chromatography

More information

https://www.indiamart.com/technoscientificproducts/

https://www.indiamart.com/technoscientificproducts/ +91-8045323702 Techno Scientific Products https://www.indiamart.com/technoscientificproducts/ We are the topmost manufacturer, exporter and supplier of Acrylic Products, Glass Museum Jar and many more.

More information

Practical 1 Procedure Iron by Titrimetry

Practical 1 Procedure Iron by Titrimetry Practical 1 Procedure Iron by Titrimetry Introduction This experiment quantifies Fe 2+, ferrous iron, by reacting it with ceric sulphate in a 1:1 reaction, i.e. one mole of ferrous iron reacts with one

More information

Dual laser + type K thermometer INFRARED THERMOMETER

Dual laser + type K thermometer INFRARED THERMOMETER Dual laser + type K thermometer INFRARED THERMOMETER Model : ATE-2509 Your purchase of this INFRARED THERMOMETER marks a step forward for you into the field of precision measurement. Although this METER

More information

Thermochemistry/Calorimetry. Determination of the enthalpy of vaporization of liquids LEC 02. What you need: What you can learn about

Thermochemistry/Calorimetry. Determination of the enthalpy of vaporization of liquids LEC 02. What you need: What you can learn about LEC 02 Thermochemistry/Calorimetry Determination of the enthalpy of vaporization of liquids What you can learn about Enthalpy of vaporisation Entropy of vaporisation Trouton s rule Calorimetry Heat capacity

More information

# 12 ph-titration of Strong Acids with Strong Bases

# 12 ph-titration of Strong Acids with Strong Bases # 12 ph-titration of Strong Acids with Strong Bases Purpose: A strong acid solution is titrated with a strong base solution. A titration curve is then used to determine the endpoint and find the concentration

More information

Chemistry Instrumental Analysis Lecture 23. Chem 4631

Chemistry Instrumental Analysis Lecture 23. Chem 4631 Chemistry 4631 Instrumental Analysis Lecture 23 A measure of how well a solution conducts electricity Water with absolutely no impurities (does not exist) Conducts electricity very poorly Impurities in

More information

WHAT ARE THE EFFECTS OF MOVING CHARGES?

WHAT ARE THE EFFECTS OF MOVING CHARGES? ELECTRICITY WHAT ARE THE EFFECTS OF MOVING CHARGES? ELECTRICAL CHARGES Most atoms have the same number of protons and electrons. They often lose and gain electrons. When this happens, the atom s charge

More information

Experiment 2 Deflection of Electrons

Experiment 2 Deflection of Electrons Name Partner(s): Experiment 2 Deflection of Electrons Objectives Equipment Preparation Pre-Lab To study the effects of electric fields on beams of fast moving electrons. Cathode-ray tube (CRT), voltage

More information

Jumbo Cross Beam Ionizer

Jumbo Cross Beam Ionizer Jumbo Cross Beam Ionizer Version 1.0 September 30, 2008 Page 1 of 19 Table of Contents Cross Beam Ionizer... 1 Table of Contents... 2 1.0 Packing List... 3 1.1 Packing List for Cross Beam Ionizer... 3

More information

Experiment C-15 Distillation - part 1

Experiment C-15 Distillation - part 1 1 Experiment C-15 Distillation - part 1 Objectives To learn about the three classical phases of matter, phase changes, and heating and cooling curves. To investigate the technique of distillation and to

More information

PREPARATIVE TASK GRAND PRIX CHIMIQUE PETNICA SCIENCE CENTER, VALJEVO, SERBIA 9 TH -14 TH OCTOBER 2017

PREPARATIVE TASK GRAND PRIX CHIMIQUE PETNICA SCIENCE CENTER, VALJEVO, SERBIA 9 TH -14 TH OCTOBER 2017 GRAND PRIX CHIMIQUE PETNICA SCIENCE CENTER, VALJEVO, SERBIA 9 TH -14 TH OCTOBER 2017 PREPARATIVE TASK Preparation of p-nitroacetanilide Preparation of vanillyl alcohol SUPPORTED BY Serbian Chemical Society

More information

Chapter 12 Tex-617, Determining Chloride in Concrete

Chapter 12 Tex-617, Determining Chloride in Concrete Chapter 12 Tex-617, Determining Chloride in Contents: Section 1 Overview... 12-2 Section 2 Apparatus... 12-3 Section 3 Preparing Solutions... 12-4 Section 4 Procedures... 12-5 Section 5 Calculations...

More information

Measurement and Lab Equipment Basics Guided Notes

Measurement and Lab Equipment Basics Guided Notes Any object has its own shape, size and dimension. In biology, it is very important to know the overall physical and chemical status of any living organism. There are specific units to describe various

More information

CHAPTER 4 THERMAL CONDUCTIVITY AND VISCOSITY MEASUREMENTS

CHAPTER 4 THERMAL CONDUCTIVITY AND VISCOSITY MEASUREMENTS 50 CHAPTER 4 THERMAL CONDUCTIVITY AND VISCOSITY MEASUREMENTS 4.1 INTRODUCTION In the development of any energy-efficient heat transfer fluids for enhanced heat transfer performance, in practical applications,

More information

Thermal and electrical conductivity of metals

Thermal and electrical conductivity of metals Thermal and electrical conductivity of metals (Item No.: P2350200) Curricular Relevance Area of Expertise: Physics Education Level: University Topic: Thermodynamics Subtopic: Heat, Work, and the First

More information

Using Conductivity to Find an Equivalence Point

Using Conductivity to Find an Equivalence Point Experiment 25 PRE LAB DISCUSSION In this experiment, you will monitor conductivity during the reaction between sulfuric acid, and barium hydroxide in order to determine the equivalence point. From this

More information

Temperature control for Varian Cary line of UV/Vis Spectrophotometers and the Eclipse Fluorometer

Temperature control for Varian Cary line of UV/Vis Spectrophotometers and the Eclipse Fluorometer Temperature control for Varian Cary line of UV/Vis Spectrophotometers and the Eclipse Fluorometer Temperature Control without Compromise: rapid changes, precise temperatures, powerful complex functionality.

More information

Scope and application: For water, wastewater and seawater. Distillation is required for wastewater and seawater.

Scope and application: For water, wastewater and seawater. Distillation is required for wastewater and seawater. Nitrogen, Ammonia DOC316.53.01078 USEPA 1 Nessler Method 2 Method 8038 0.02 to 2.50 mg/l NH 3 N Reagent Solution Scope and application: For water, wastewater and seawater. Distillation is required for

More information

Determination of the Equivalent Weight and the K a or K b for a Weak Acid or Base

Determination of the Equivalent Weight and the K a or K b for a Weak Acid or Base INTRODUCTION Determination of the Equivalent Weight and the K a or K b for a Weak Acid or Base Chemists frequently make use of the equivalent weight (eq. wt.) as the basis for volumetric calculations.

More information

Teacher s notes 15 Temperature volume relationship in a gas (Charles law, Gay-Lussac s law)

Teacher s notes 15 Temperature volume relationship in a gas (Charles law, Gay-Lussac s law) Sensors: Loggers: Temperature, Rotary Motion Any EASYSENSE Physics Logging time: EasyLog Teacher s notes 15 Temperature volume relationship in a gas (Charles law, Gay-Lussac s law) Read The relationship

More information

Electrochemistry LEC Potentiometric ph titration (phosphoric acid in a soft drink) What you need: What you can learn about

Electrochemistry LEC Potentiometric ph titration (phosphoric acid in a soft drink) What you need: What you can learn about Electrochemistry LEC 06 What you can learn about Galvanic cell Types of electrodes Nernst equation Potentiometry Principle and tasks The cell voltage and the Galvani voltage of the electrodes of an galvanic

More information

X-CELL Analytical. Petroleum Fluids Analysis. St. Francis Xavier University Analytical Services Lab. Equipment Specification Brochure

X-CELL Analytical. Petroleum Fluids Analysis. St. Francis Xavier University Analytical Services Lab. Equipment Specification Brochure X-CELL Analytical Petroleum Fluids Analysis St. Francis Xavier University Analytical Services Lab Equipment Specification Brochure Physical Sciences Center PO Box 5000 Antigonish, NS, B2G 2W5 Canada Phone:

More information

ph Electrode basics ph Electrodes Model 19 B /1 =1 m 24 B /1 =1 m

ph Electrode basics ph Electrodes  Model 19 B /1 =1 m 24 B /1 =1 m s ph electrodes are constructed from a special composition which senses the hydrogen ion concentration. This is typically composed of alkali metal ions. The alkali metal ions of the and the hydrogen ions

More information

AP Chemistry: Designing an Effective Hand Warmer Student Guide INTRODUCTION

AP Chemistry: Designing an Effective Hand Warmer Student Guide INTRODUCTION AP Chemistry: Designing an Effective Hand Warmer Student Guide INTRODUCTION AP and the Advanced Placement Program are registered trademarks of the College Entrance Examination Board. The activity and materials

More information

Exp 1 Column Chromatography for the Isolation of Excedrin Components. Reading Assignment: Column Chromatography, TLC (Chapter 18)

Exp 1 Column Chromatography for the Isolation of Excedrin Components. Reading Assignment: Column Chromatography, TLC (Chapter 18) Exp 1 Column Chromatography for the Isolation of Excedrin Components Reading Assignment: Column Chromatography, TLC (Chapter 18) Column chromatography separation can be achieved if the compounds have different

More information

Tex-620-J, Determining Chloride and Sulfate Contents in Soil

Tex-620-J, Determining Chloride and Sulfate Contents in Soil Contents in Soil Contents: Section 1 Overview...2 Section 2 Sample Preparation...3 Section 3 Ion Chromatography Method...5 Section 4 Wet Chemical Method...9 Section 5 Archived Versions...15 Texas Department

More information

testo 205, 206, 230 Compact ph Measuring Instruments With Pro Engineering With interchangeable measurement electrode Draft Version

testo 205, 206, 230 Compact ph Measuring Instruments With Pro Engineering With interchangeable measurement electrode Draft Version testo 205, 206, 230 Compact ph Measuring Instruments With Pro Engineering With interchangeable measurement electrode Draft Version ph C The new ph measuring instruments with innovative probe engineering

More information

National 5 Physics. Electricity and Energy. Notes

National 5 Physics. Electricity and Energy. Notes National 5 Physics Electricity and Energy Notes Name. 1 P a g e Key Area Notes, Examples and Questions Page 3 Conservation of energy Page 10 Electrical charge carriers and electric fields and potential

More information

HMS-5000 Manual. Product Name: HMS-5000 Hall Effect Measurement System with variable temperature from 80K to 350K. - Manual version: ver 5.

HMS-5000 Manual. Product Name: HMS-5000 Hall Effect Measurement System with variable temperature from 80K to 350K. - Manual version: ver 5. HMS-5000 Manual Product Name: HMS-5000 Hall Effect Measurement System with variable temperature from 80K to 350K - Manual version: ver 5.01- www.ecopia21.co.kr - Table of contents - 1. Hardware Installation

More information

637. Thiamethoxam. HPLC method

637. Thiamethoxam. HPLC method 637. Thiamethoxam HPLC method CIPAC Collaborative Trial according to CIPAC Information Sheet N o 293 Dr. Sven Adolph Syngenta Crop Protection Münchwilen AG CH-4333 Münchwilen Switzerland May 212 page 1

More information

THE CONSERVATION OF ENERGY - PENDULUM -

THE CONSERVATION OF ENERGY - PENDULUM - THE CONSERVATION OF ENERGY - PENDULUM - Introduction The purpose of this experiment is to measure the potential energy and the kinetic energy of a mechanical system and to quantitatively compare the two

More information

Aarson Scientific Works

Aarson Scientific Works +91-8048601109 Aarson Scientific Works https://www.indiamart.com/aarsonscientificworks/ We are engaged in Manufacturing, Trading, Exporting and Supplying of Microscopes Lab Equipment, Audio Visual Equipment,

More information

CHEMICAL SEPARATION EXPERIMENT 2

CHEMICAL SEPARATION EXPERIMENT 2 CHEMICAL SEPARATION EXPERIMENT 2 INTRODUCTION The term analysis in chemistry usually refer to the quantitative and qualitative determination of the components of a sample. Qualitative refering to the identity

More information

PHY222 Lab 8 - Magnetic Fields and Right Hand Rules Magnetic forces on wires, electron beams, coils; direction of magnetic field in a coil

PHY222 Lab 8 - Magnetic Fields and Right Hand Rules Magnetic forces on wires, electron beams, coils; direction of magnetic field in a coil PHY222 Lab 8 - Magnetic Fields and Right Hand Rules Magnetic forces on wires, electron beams, coils; direction of magnetic field in a coil Print Your Name Print Your Partners' Names You will return this

More information

STUD & TRACK ROLL FORMING MACHINE

STUD & TRACK ROLL FORMING MACHINE STUD & TRACK ROLL FORMING MACHINE R O L L F O R M E R S U S A I W W W. R O L L F O R M E R S - U S A. C O M Page1 Cantilevered Dual Headed 6,000 lb Decoiler Includes mandrel and stand Can accommodate 22

More information

Hess' Law: Calorimetry

Hess' Law: Calorimetry Exercise 9 Page 1 Illinois Central College CHEMISTRY 130 Name: Hess' Law: Calorimetry Objectives The objectives of this experiment are to... - measure the heats of reaction for two chemical reactions.

More information

CALYS 120 IS. ATEX documenting multifunction calibrator with high accuracy 0.006%

CALYS 120 IS. ATEX documenting multifunction calibrator with high accuracy 0.006% ATEX documenting multifunction calibrator with high accuracy 0.006% is the top instrument of our range of ATEX documenting multifunction calibrators. Description is the top instrument of our range of ATEX

More information

PRETREATMENT TECHNICAL DATA SHEET A CHROME-FREE FINAL RINSE PRODUCT DESCRIPTION

PRETREATMENT TECHNICAL DATA SHEET A CHROME-FREE FINAL RINSE PRODUCT DESCRIPTION INDUSTRIAL COATINGS CS59 PRETREATMENT TECHNICAL DATA SHEET A CHROME-FREE FINAL RINSE PRODUCT DESCRIPTION is a chromium-free concentrate for use as a final rinse after phosphate with CHEMFOS iron or zinc

More information

Commercial Chip - R3L 16Vdc to 5kVdc

Commercial Chip - R3L 16Vdc to 5kVdc Commercial Chip - R3L 16Vdc to 5kVdc A range of commercial MLC chip capacitors in R3L dielectric. This is a Class I temperature compensating N22 dielectric with an energy density that exceeds conventional

More information

OPERATION MANUAL. 3 in 1, IR, Type K/J/R/E/T, Pt 100 ohm THERMOMETER. Model : TM-2000

OPERATION MANUAL. 3 in 1, IR, Type K/J/R/E/T, Pt 100 ohm THERMOMETER. Model : TM-2000 3 in 1, IR, Type K/J/R/E/T, Pt 100 ohm THERMOMETER Model : TM-2000 Your purchase of this THERMOMETER marks a step forward for you into the field of precision measurement. Although this THERMOMETER is a

More information

Measurements & Instrumentation. Module 3: Temperature Sensors

Measurements & Instrumentation. Module 3: Temperature Sensors Measurements & Instrumentation PREPARED BY Academic Services Unit August 2013 Institute of Applied Technology, 2013 Module Objectives Upon successful completion of this module, students should be able

More information

Thermochemistry/Calorimetry LEC Heat capacity of gases. What you need: What you can learn about. Principle and tasks

Thermochemistry/Calorimetry LEC Heat capacity of gases. What you need: What you can learn about. Principle and tasks Thermochemistry/Calorimetry LEC 02 What you can learn about 1st law of thermodynamics Universal gas constant Isobars Isotherms Isochors and adiabatic changes of state Principle and tasks Heat is added

More information

DIPLOMA IN ENGINEERING I YEAR II SEMESTER

DIPLOMA IN ENGINEERING I YEAR II SEMESTER GOVERNMENT OF TAMILNADU DIRECTORATE OF TECHNICAL EDUCATION DIPLOMA IN ENGINEERING I YEAR SEMESTER SYSTEM L - SCHEME 2011-2012 II SEMESTER ENGINEERING CHEMISTRY II PRACTICAL CURRICULUM DEVELOPMENT CENTER

More information

IR F ( C) ENGLISH INSTRUCTION MANUAL. Thermometer

IR F ( C) ENGLISH INSTRUCTION MANUAL. Thermometer INSTRUCTION MANUAL Thermometer DUAL-LASER TARGETING 12:1 DISTANCE- TO-SPOT RATIO AUTO-SCAN MAX/MIN/AVG/DIFF HIGH/LOW ALARM BACKLIT DISPLAY AUTO POWER-OFF ADJUSTABLE EMISSIVITY IR5 2m -22 752 F (-30 400

More information

Medium Pressure Sensor Analog Output

Medium Pressure Sensor Analog Output Medium Pressure Sensor Analog Output SM6844-015-A-B-5-S FEATURES Analog pressure calibrated and temperature compensated output Amplified analog output Compensated temperature range: 0 to 85oC Absolute

More information

Conductometric Titration & Gravimetric Determination of a Precipitate

Conductometric Titration & Gravimetric Determination of a Precipitate Conductometric Titration & Gravimetric Determination of a Precipitate Experiment 9 In this experiment, you will monitor conductivity during the reaction between sulfuric acid, H2SO4, and barium hydroxide,

More information

FrelTec GmbH. Multilayer Chip Ferrite Bead SMD

FrelTec GmbH. Multilayer Chip Ferrite Bead SMD GmbH Mathildenstr. 10A 82319 Starnberg Germany SMD 3/21/2017 1/12 GmbH www.freltec.com SPECIFICATION Part Number 198 05 * 151 * S * Q * E02 Type Size Nominal Impedance Material Rated Current Tolera nce

More information

Petrochemical. Transformer Oil Gas Analysis - TOGA

Petrochemical. Transformer Oil Gas Analysis - TOGA Petrochemical Transformer Oil Gas Analysis - TOGA www.dps-instruments.com The DPS TOGA GC Systems are designed to analyze oil from electrical insulation materials that may have decomposed under thermal,

More information

IDENTIFICATION OF STEROIDS IN COSMETIC PRODUCTS BY TLC AND HPLC 1 02/12/2005 ACM 007 A. THIN LAYER CHROMATOGRAPHY (TLC)

IDENTIFICATION OF STEROIDS IN COSMETIC PRODUCTS BY TLC AND HPLC 1 02/12/2005 ACM 007 A. THIN LAYER CHROMATOGRAPHY (TLC) Document A. THIN LAYER CHROMATOGRAPHY (TLC) 1. SCOPE AND FIELD OF APPLICATION The method describes the identification of hydrocortisone acetate, dexamethasone, betamethasone, betamethasone 17-valerate

More information

Shown below is a sample titration curve for a diprotic acid. Note the two equivalence points.

Shown below is a sample titration curve for a diprotic acid. Note the two equivalence points. EXPERIMENT 9 Titration Curve for a Polyprotic Acid INTRODUCTION Other than by strength and concentration, another way of classifying acids involves the number of H + ions an acid can donate. A monoprotic

More information

OPERATION MANUAL. Acceleration, Velocity RMS measurement, Metric & Imperial unit PEN VIBRATION METER Model : PVB-820

OPERATION MANUAL. Acceleration, Velocity RMS measurement, Metric & Imperial unit PEN VIBRATION METER Model : PVB-820 Acceleration, Velocity RMS measurement, Metric & Imperial unit PEN VIBRATION METER Model : PVB-820 Your purchase of this PEN VIBRATION METER marks a step forward for you into the field of precision measurement.

More information

#13 ph-titration of Weak Acids with Strong Bases

#13 ph-titration of Weak Acids with Strong Bases #13 ph-titration of Weak Acids with Strong Bases Purpose: A weak acid solution is titrated with a strong base solution. A titration curve is then used to identify the unknown acid and to find its concentration.

More information

LM35 Precision Centigrade Temperature Sensors

LM35 Precision Centigrade Temperature Sensors LM35 Precision Centigrade Temperature Sensors General Description The LM35 series are precision integrated-circuit temperature sensors, whose output voltage is linearly proportional to the Celsius (Centigrade)

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. J. A. KING & COMPANY, LLC 8813 Old Craft Road Olive Branch, MS CONNIE FOSTER PHONE:

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. J. A. KING & COMPANY, LLC 8813 Old Craft Road Olive Branch, MS CONNIE FOSTER PHONE: SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 J. A. KING & COMPANY, LLC 8813 Old Craft Road Olive Branch, MS 38654 CONNIE FOSTER PHONE: 800 327 7727 CALIBRATION Valid To: August 31, 2019 Certificate Number:

More information

Elcometer 116C. Sling Hygrometer. Operating Instructions

Elcometer 116C. Sling Hygrometer. Operating Instructions Elcometer 116C English Sling Hygrometer Operating Instructions English is a registered trademark of Elcometer Limited. All other trademarks acknowledged. Copyright Elcometer Limited. 2008. All rights reserved.

More information

5.37 Introduction to Organic Synthesis Laboratory

5.37 Introduction to Organic Synthesis Laboratory MIT pencourseware http://ocw.mit.edu 5.37 Introduction to rganic Synthesis Laboratory Spring 2009 For information about citing these materials or our Terms of Use, visit: http://ocw.mit.edu/terms. URIECA

More information

Chromatography- Separation of mixtures CHEM 212. What is solvent extraction and what is it commonly used for?

Chromatography- Separation of mixtures CHEM 212. What is solvent extraction and what is it commonly used for? Chromatography- Separation of mixtures CHEM 212 What is solvent extraction and what is it commonly used for? How does solvent extraction work? Write the partitioning coefficient for the following reaction:

More information

CHEM E7115 Experimental Assignments in Chemical Engineering Internal mass transfer in a heterogeneously catalyzed reaction

CHEM E7115 Experimental Assignments in Chemical Engineering Internal mass transfer in a heterogeneously catalyzed reaction CHEM AXXX Kurssin nimi CHEM E7115 Experimental Assignments in Chemical Engineering Internal mass transfer in a heterogeneously catalyzed reaction 1. Before you come to the lab Before you come to do the

More information

DEVELOPMENT OF DROP WEIGHT IMPACT TEST MACHINE

DEVELOPMENT OF DROP WEIGHT IMPACT TEST MACHINE CHAPTER-8 DEVELOPMENT OF DROP WEIGHT IMPACT TEST MACHINE 8.1 Introduction The behavior of materials is different when they are subjected to dynamic loading [9]. The testing of materials under dynamic conditions

More information

PRETREATMENT TECHNICAL DATA SHEET CHROMIUM-FREE ORGANIC PASSIVATING RINSE PRODUCT DESCRIPTION

PRETREATMENT TECHNICAL DATA SHEET CHROMIUM-FREE ORGANIC PASSIVATING RINSE PRODUCT DESCRIPTION INDUSTRIAL COATINGS CS100 PRETREATMENT TECHNICAL DATA SHEET CHROMIUM-FREE ORGANIC PASSIVATING RINSE PRODUCT DESCRIPTION is a chromium-free organic passivating rinse. It is formulated to provide improved

More information

Level 1 Physics, 2016

Level 1 Physics, 2016 90937 909370 1SUPERVISOR S Level 1 Physics, 2016 90937 Demonstrate understanding of aspects of electricity and magnetism 2.00 p.m. Tuesday 15 November 2016 Credits: Four Achievement Achievement with Merit

More information

[Agilent Technologies] [Electrochemistry Products] Quick Reference

[Agilent Technologies] [Electrochemistry Products] Quick Reference Overview Using I9121 Ammonia Gas Sensing Probe on 3200I/M This document demonstrates how to use I 9121 Ammonia Gas Sensing Probe on 3200I or 3200 M to measure pn or the concentration of [NH 4 + ]. Applied

More information

Unit 1. The Math of Chemistry

Unit 1. The Math of Chemistry Unit 1 The Math of Chemistry Lab Safety Lab Safety http://www.flinnsci.com/teacher-resources/teacher-resource-videos/best-practices-for-teaching-chemistry/safety/laboratory-safety-challenge/ Laboratory

More information

Acceleration/Velocity/Displacement VIBRATION METER

Acceleration/Velocity/Displacement VIBRATION METER Acceleration/Velocity/Displacement VIBRATION METER Model : VB-8220 Your purchase of this VIBRATION METER marks a step forward for you into the field of precision measurement. Although this METER is a complex

More information

Prelab Reading Assignment: Laboratory Techniques in Organic Chemistry, 4 th Ed. Chapter 19

Prelab Reading Assignment: Laboratory Techniques in Organic Chemistry, 4 th Ed. Chapter 19 CHEM 213 Technique Experiments Experiment 5: Column Chromatography Number of labs - one Reactions performed None Chemicals used: Fluorene-fluorenone mixture, hexanes, methylene chloride, silica gel Supplies

More information

TOL-CFcPGKC. Lamp LED. Features. Dimensions. Chip Lens Color. Part Number. TOL-CFcPGKC AlGaInP Pure Green Water clear

TOL-CFcPGKC. Lamp LED. Features. Dimensions. Chip Lens Color. Part Number. TOL-CFcPGKC AlGaInP Pure Green Water clear TOL-CFcPGKC Lamp LED Part Number Material Chip Source Color Lens Color TOL-CFcPGKC AlGaInP Pure Green Water clear Features I.C. compatible. Low power consumption. Compatible with wave soldering process.

More information

CONSTANT PRESSURE CALORIMETRY: A STUDY OF GLYCINE PROTON-TRANSFER ENTHALPIES 1

CONSTANT PRESSURE CALORIMETRY: A STUDY OF GLYCINE PROTON-TRANSFER ENTHALPIES 1 CONSTANT PRESSURE CALORIMETRY: A STUDY OF GLYCINE PROTON-TRANSFER ENTHALPIES 1 OBJECTIVES 1. To determine the reaction enthalpies for the proton transfer reactions of glycine. 2. To use a high-precision

More information

Electric Fields and Equipotentials

Electric Fields and Equipotentials Electric Fields and Equipotentials Note: There is a lot to do in this lab. If you waste time doing the first parts, you will not have time to do later ones. Please read this handout before you come to

More information

Total Carboxylic Acid Group Content Applicable Products: Carbopol * Polymers and Pemulen * Polymeric Emulsifiers

Total Carboxylic Acid Group Content Applicable Products: Carbopol * Polymers and Pemulen * Polymeric Emulsifiers LUBRIZOL TEST PROCEDURE TP-1318-A Edition: August, 2010 Total Carboxylic Acid Group Content Applicable Products: Carbopol * Polymers and Pemulen * Polymeric Emulsifiers Scope: This procedure is used for

More information

Experiment Nine Thin Layer Chromatography

Experiment Nine Thin Layer Chromatography Name: Lab Section: 09 Thin Layer Chromatography Experiment Nine Thin Layer Chromatography Introduction Objective Separation of compounds from a mixture is an incredibly important aspect of experimental

More information

15. Compare the result with the value you have taken above Compare the calculated pressure value with the actual pressure value that you have

15. Compare the result with the value you have taken above Compare the calculated pressure value with the actual pressure value that you have 105) to convert it to. 15. Compare the result with the value you have taken above. 17. 16. Compare the calculated pressure value with the actual pressure value that you have taken from the, is it the same?

More information

Experiment 6: Dehydration of 2-Methylcyclohexanol

Experiment 6: Dehydration of 2-Methylcyclohexanol Experiment 6: Dehydration of 2-Methylcyclohexanol Dehydration of 2-Methylcyclohexanol This week's reaction: A B - dehydration of a 2 alcohol to give a mixture of alkene isomers - H 3 PO 4 is a catalyst

More information

Approximate Volatile Acids by Titration

Approximate Volatile Acids by Titration SOP AMBL-101-A Page 1 of 5 Standard Operating Procedure AMBL-101-A Prepared: April 12, 2006 Revised: July 16, 2014 Prepared by: Terry E. Baxter Reviewed by: Approximate Volatile Acids by Titration METHOD

More information

BV SERIES. VERTICAL BLOWER COIL UNITS Nominal Sizes 2 thru 10 Ton

BV SERIES. VERTICAL BLOWER COIL UNITS Nominal Sizes 2 thru 10 Ton BV SERIES VERTICAL BLOWER COIL UNITS Nominal Sizes 2 thru 10 Ton MAGIC AIRE BV SERIES FAN COILS ARE ETL LISTED TO U.S. AND CANADIAN SAFETY STANDARDS AND ARE ASSEMBLED TO ORDER FOR COMPETITIVE DELIVERY.

More information

FrelTec GmbH. Thick Film Chip Resistor SMD Low Ohm

FrelTec GmbH. Thick Film Chip Resistor SMD Low Ohm GmbH Mathildenstr. 10A 82319 Starnberg Germany Thick Film Chip Resistor SMD Low Ohm 9/10/2012 1/13 GmbH www.freltec.com SPECIFICATION Part Number 016 05 * 001k * J * T05 ** *** Type Size Value Tolerance

More information

Is There a Chemist in You?

Is There a Chemist in You? Young Scholars of Utica http://www.utica.edu/academic/yslpp/ Workshop January 8, 2011 Hosts: Professor Myriam Cotten, Lydia Rono, and Akritee Shrestha Is There a Chemist in You? 1 Schedule Morning Why

More information

THM80X Series Feature Application. Temperature & Humidity / Flow Measuring Specialist

THM80X Series  Feature Application. Temperature & Humidity / Flow Measuring Specialist THM80X Series Feature Application IP67 protection degree, rugged aluminum case, fit in variety harsh environment Capable of temperature compensation Linear adjustment temperature & humidity by computer,

More information

One-hand ph/temperature measuring instrument

One-hand ph/temperature measuring instrument One-hand ph/temperature measuring instrument testo 205 ph tip embedded in breakage-proof plastic ph Combined penetration tip with temperature probe Maintenance-free gel electrolyte C Measurement tip exchangeable

More information

TEKS Physics, Beginning with School Year Correlation to CPO Science Link

TEKS Physics, Beginning with School Year Correlation to CPO Science Link TEKS Physics. (c) Knowledge and skills. (1) Scientific processes. The student conducts investigations, for at least 40% of instructional time, using safe, environmentally appropriate, and ethical practices.

More information

PMLCAP. Polymer Multi Layer Capacitor Specification Sheet RUBYCON CORPORATION PML DIVISION. PMLCAP ST series RPR Rubycon PART No. Drawing No.

PMLCAP. Polymer Multi Layer Capacitor Specification Sheet RUBYCON CORPORATION PML DIVISION. PMLCAP ST series RPR Rubycon PART No. Drawing No. To Polymer Multi Layer Capacitor Specification Sheet Rubycon PART No. ST series Drawing No. RPR-0024 Issued Date October 15, 2008 PML DIVISION 2932, MOTOOSHIMA, MATSUKAWA-MACHI, SHIMOINA-GUN, NAGANO-KEN,

More information

Determination of freezing points of pure substances with Cobra4 TEC

Determination of freezing points of pure substances with Cobra4 TEC Determination of freezing points of pure substances TEC Related concept Crystallization point, Gibbs free energy, enthalpy, entropy, heat of fusion, freezing point depression. Principle When a pure substance

More information