Jumbo Cross Beam Ionizer

Size: px
Start display at page:

Download "Jumbo Cross Beam Ionizer"

Transcription

1 Jumbo Cross Beam Ionizer Version 1.0 September 30, 2008 Page 1 of 19

2 Table of Contents Cross Beam Ionizer... 1 Table of Contents Packing List Packing List for Cross Beam Ionizer Optional Accessories for Cross Beam Ionizer Product Identification Scope of Manual Intended Use Safety Vacuum Pressure Considerations Liability and Warranty Product Overview Summary Installation Installing the Cross Beam Ionizer Electrical Connections Commissioning Initial Operation Tuning as a Molecular Beam Ionizer Tuning as Focusing Optics for Pre-formed Ions Tuning the Outer Pole Potential Typical Performance Data Filament Voltage and Current Maintenance and Care Cleaning Appendices: Assembly Drawings Page 2 of 19

3 1.0 Packing List 1.1 Packing List for Jumbo Cross Beam Ionizer The Jumbo Cross Beam Ionizer is shipped with the following items: Table 1. Jumbo Cross Beam Ionizer Packing List Quantity Part Number Description 1 Jumbo Cross Beam Ionizer for large quadrupoles 4 (spare) Ceramic washer, inch o.d., inch thick X ¼ Socket Head Cap Screws Split Lock Washers 1.2 Optional Accessories for Jumbo Cross Beam Ionizer The Jumbo Cross Beam Ionizer can be attached to various quadrupole lensmounting plates, customized to the user s existing quadrupole. Table 2. Optional Accessories for Jumbo Cross Beam Ionizer Quantity Part Number Description 1 Entrance Lens Assembly for Extrel 6 or 9.5 mm Quadrupole 1 Entrance Lens Assembly for Extrel 16 mm Quadrupole 1 Entrance Lens Assembly for Extrel 19 mm Quadrupole 2.0 Product Identification In all communication with Ardara Technologies, please specify the Ardara Technologies part number for the ionizer from your original purchase order. 3.0 Scope of Manual This manual applies to the Ardara Technologies Jumbo Cross Beam Ionizers which incorporate an axial molecular beam ionizer and a quadrupole deflector energy filter. This document is valid as of the date of publication. We reserve the right to make technical changes to the design. Page 3 of 19

4 4.0 Intended Use 5.0 Safety The Ardara Technologies Jumbo Cross Beam Ionizer was designed to provide exceptionally high sensitivity for analysis of ions and neutrals from a customer s molecular beam, which is oriented orthogonally to the quadrupole. Specially, designed to better match the large acceptance of larger quadrupoles, especially at higher RF frequencies. This ionizer is intended for use with molecular beams and ion beams that are reactive, condensable or sampled from a higher-pressure gas source. Its rightangle orientation to the axis of the quadrupole allows for effective separation of the ions of choice from the background gas load, while minimizing the gas flow into the mass analyzer. The Jumbo Cross Beam Ionizer was designed to operate inside a vacuum system, with voltages applied to adjacent electrodes as high as plus or minus 400 volts. 5.1 Vacuum Pressure Considerations The Jumbo Cross Beam Ionizer was designed to operate inside a vacuum system, with vacuum levels maintained below 10-5 torr. Operation at pressures above this maximum pressure may result in dramatically lower filament lifetime, as well as the potential for glow discharge between adjacent high voltage electrodes. 6.0 Liability and Warranty Ardara Technologies assumes no liability and the warranty becomes null and void if the end user or third parties: Disregard the information in this manual Use the product in a non-conforming manner Make any kind of changes (modifications, alterations, etc.) to the Jumbo Cross Beam Ionizer. Page 4 of 19

5 7.0 Product Overview 7.1 Summary The Ardara Technologies Jumbo Cross Beam Ionizer consists of a molecular beam ionizer coupled to a quadrupole deflector energy filter, which serves to deflect the ions ninety degrees from the entrance aperture of the molecular beam. The molecular beam ionizer portion of the Ardara Technologies Jumbo Cross Beam Ionizer is a Brink type ionizer, consisting of a metal basket (Platinum wire), which is surrounded by a network of coated molybdenum framework. The molecular beam ionizer has a filament shield which has an entrance aperture, which defines the maximum cross section of the molecular beam, inches. A customer-supplied filament power supply will provide suitable regulated current and voltage to maintain constant emission current, with the more negative of the two filament connections to be applied to the upper filament plate (closest to the ion beam aperture), and the less negative connection to be applied to the lower filament plate. The filament shield is maintained at the more negative of the two filament connections by way of a metal washer placed between the filament shield and the upper filament plate. All electrical connections to the Cross Beam Ionizer are made via 2-56 screw connections to holes threaded radially for the respective lenses. Typically, copper wires are used for the filament connections, and nickel wire is used for the lens connections. The Quadrupole Deflector Energy Filter portion of the Jumbo Cross Beam Ionizer is constructed from four hyperbolic rods oriented such that the ion beam is directed between adjacent rods. With suitable voltages applied to the deflector poles, the ion beam can be directed to travel a path ninety degrees from their entrance. The deflector pole pair that includes the pole which is between the molecular beam ionizer and the quadrupole is identified as the Inner Pole pair, with the other pole pair identified as the Outer Pole pair. The Quadrupole Deflector Energy Filter utilizes a vacuum compatible resistive voltage divider (5 megaohm) attached between the deflector poles, with the centerline potential of the poles as maintained by the voltage divider applied to the deflector entrance lens, top and bottom pole plates, and in some cases the deflector exit lens. An optional optimization utilizes a separate lens supply to drive the deflector exit lens, instead of the standard configuration of connecting the deflector exit lens to the centerline potential of the deflector. Page 5 of 19

6 The Jumbo Cross Beam Ionizer is typically configured with two bipolar 100 volt power supplies for the ion region and extraction lens, and two bipolar 400 volt power supplies for the deflector assembly, although a third bipolar 400 volt power supply is commonly used to drive the deflector exit lens. The deflector can operate with bipolar 200 volt or 100 volt power supplies with modest reduction in performance. Under certain tuning conditions (small voltage difference between the pole pairs), the quadrupole deflector can be utilized as an energy filter, with the centerline potential of the deflector indicative of the average energy of the passed ion beam, and the voltage difference between poles controlling ion energy bandpass. Page 6 of 19

7 8.0 Installation 8.1 Installing the Jumbo Cross Beam Ionizer Installation of the Jumbo Cross Beam Ionizer onto a quadrupole requires that the ionizer be first mounted to the quadrupole entrance lens, and then the quadrupole entrance lens is mounted to the quadrupole itself. Figure 1. Mounting the Jumbo Cross Beam Ionizer to the Quadrupole Entrance Lens. Page 7 of 19

8 8.2 Electrical Connections A total of six (optionally seven) wires are required to power the Jumbo Cross Beam Ionizer. See Figure 2 below for a block diagram showing the vacuum wiring for the Jumbo Cross Beam Ionizer. Figure 2. Wiring Block Diagram for Jumbo Cross Beam Ionizer. Figure 3. Pinout of Vacuum side of MS-10 Connector. Page 8 of 19

9 Table 3. Jumbo Cross Beam Ionizer Electrical Connections when six lens optics supplies are available MS-10 Connector Pin Description Typical Voltage A Outer Poles 0 V B Inner Poles -200 V C Filament (+) D Filament (-) 100 ev E Ion Region +8 V F Exit Lens -100 V G Extractor -2 V H Entrance Lens -10 V I J Not Connected Not Connected Table 4. Jumbo Cross Beam Ionizer Electrical Connections when seven lens optics supplies are available MS-10 Connector Pin Description Typical Voltage A Outer Poles 0 V B Inner Poles -200 V C Filament (+) D Filament (-) 100 ev E Ion Region +8 V F Exit Lens -100 V G Extractor -2 V H Entrance Lens -10 V I Deflector Exit Lens -100 V J Not Connected Page 9 of 19

10 Table 5. Jumbo Cross Beam Ionizer Electrical Connections when eight lens supplies are available MS-10 Connector Pin Description Typical Voltage A Outer Poles 0 V B Inner Poles -200 V C Filament (+) D Filament (-) 100 ev E Ion Region +8 V F Exit Lens -100 V G Extractor -2 V H Entrance Lens -10 V I Deflector Exit Lens -100 V J Pre- and Post-filters -10 V Page 10 of 19

11 9.0 Commissioning 9.1 Initial Operation Once the Jumbo Cross Beam Ionizer is installed onto the quadrupole mass filter, and the electrical connections are made, the unit is ready to install into a vacuum chamber. When a suitable vacuum is attained, the ionizer is ready for operation. For Merlin software-based systems, the configuration file should be edited to change the aliases for optics elements 3 and 4, from Lens 1/3 and Lens 2 to Inner Poles and Outer Poles, with the defaults changed to -200 volts for the Inner Poles, and 0 volts for the Outer Poles. The Jumbo Cross Beam Ionizer is not difficult to tune, so long as the initial voltages match the defaults identified in this manual. Caution: In contrast to typical molecular beam ionizers, it is possible to tune the voltages on the Jumbo Cross Beam Ionizer such that no ions travel to the quadrupole. For example, if the Inner Poles and Outer Poles are set to the same voltage, then ions will not bend ninety degrees to the quadrupole, rather they will travel straight through to the deflector to strike the chamber wall. This feature has been used in some installations to couple a single ion source to multiple analyzers, as well as a gate to selectively inject ions into the quadrupole via some timing sequence on the applied voltages. 9.1 Tuning as a Molecular Beam Ionizer When the filament is enabled, the Jumbo Cross Beam Ionizer serves as a molecular beam ionizer, ionizing the gas species from a molecular beam passing through the ionizer as well as any residual gas background species present in the vacuum chamber. The ion region potential and the extraction lens potential have great influence on the ion energy of the ions as they travel through the quadrupole. These voltages should generally be optimized for smooth peak shapes with the highest ion current. Default values of +8 volts for the ion region and -2 volts for the extractor should yield reasonable peak shape and ion signal for a 1.2 MHz quadrupole, although for lower frequency quadrupoles, the ion region potential should be reduced by a volt or two for better peak shapes. The extraction region typically tunes to a value that is a few to ten volts more negative than the ion region potential, and is generally tuned for maximum signal. The selection of the Inner Pole potential is generally based on the desired bandpass range of ion energies. Settings in the range of -100 to -400 volts Page 11 of 19

12 generally tune to yield similar ion intensities, with optimum peak shapes tending towards lower Inner Pole potentials. A good value to use is -200 volts. Once the Inner pole potential is selected, the outer pole potential is optimized to yield the maximum ion signal, with reasonable peak shape. For ion region potentials just positive from ground, the optimum Inner Pole Potential is typically a few to ten volts positive from ground. The potential difference between the inner and outer poles defines the energy bandpass of the energy filter. The entrance and exit aperture sizes also have influence on energy bandpass, although the aperture diameters for this design were chosen for highest throughput, minimizing the energy selection capability of the ionizer. Replacing these lenses with ones of smaller diameter would increase energy resolution at the expense of sensitivity. 9.1 Tuning as Focusing Optics for Pre-formed Ions When the filament is disenabled, the Jumbo Cross Beam Ionizer can serve as focusing optics to bring an ion beam into the quadrupole mass filter. With the filament disabled, the electron energy control (ev command), can be used as a focusing lens voltage as applied to the filament shield, which doubles as a focusing lens. In Merlin systems, this has a voltage range of -200 to 200 V which is typically maintained 100 volts more negative than the ion region. Note that the voltage identified on the Merlin tune screen is relative to the ion region potential, not relative to ground. When you change the ion region potential the Filament Shield potential will move with the ion region. Page 12 of 19

13 9.2 Tuning the Outer Pole Potential When the Outer Pole potential is tuned, and ion intensity is plotted as a function of Outer Pole potential, one can identify a smooth broad maximum, as shown in Figure 4. Figure 4. Tuning Curve showing ion intensity as a function of Outer Pole potential with Inner Pole potential maintained at -400 V. Note that the optimum Outer Pole potential is +4 V, and that the vertical grid lines represent ten volt steps. Peak width at half maximum is ~20 Volts. Page 13 of 19

14 10.0 Typical Performance Data 10.1 Filament Voltage and Current Filament Voltage and Filament Current are useful diagnostics. In the Merlin data system, these values can be measured by clicking on the Update button for each element in the tune screen. The resistance of the filament increases with increasing temperature. The effective resistance of the filament can thus be calculated from the filament voltage and current (V=IR). Note that the filament voltage is the measured voltage drop across the heated filament, and the filament current is the measured current through the filament itself. In contrast, the Emission Current is the measured current of electrons leaving the filament circuit through vacuum to the ionizer, and the Electron Energy (ev) is the potential difference maintained between the filament circuit and the ion region. As the chamber vacuum pressure increases, it requires more heat from the filament to maintain emission, and hence the filament temperature increases. (This is the principle behind pirani pressure gauges.) When the filament is operated at higher emission current, it also requires higher filament temperature. Table 6 illustrates typical measured Filament Voltage and Filament Currents for an ionizer operated in the 10-6 torr range. Table 6. Typical Filament Current and Filament Voltage for different Emission Currents using a Cross Beam Ionizer Emission Current (ma) Filament Voltage (amperes) Filament Voltage (volts) Page 14 of 19

15 It is recommended that the user monitor the filament voltage and current as part of their routine daily diagnostics to ultimately use their data as a predictor of filament lifetime Maintenance and Care 11.1 Cleaning Use standard vacuum cleaning procedures to remove contamination from the stainless steel parts. A typical cleaning procedure would entail the following: 1. Disassemble ionizer. 2. Mechanically scrub stainless steel components with a slurry of Alconox and aluminum oxide or pumice. 3. Use deionized water to rinse any residue of the Alconox and aluminum oxide. 4. Place parts in a dilute solution of Alconox and water and sonicate in an ultrasonic bath for 20 minutes at 50 o C. 5. Use deionized water to rinse the Alconox residue. 6. Place parts in a dilute solution of Citrinox and water and sonicate in an ultrasonic bath for 20 minutes at 50 o C. 7. Use deionized water to rinse any Citrinox residue 8. After deionized water rinse of Citrinox solution, perform multiple rinses using small quantities of deionized water, and then air dry. At this point the parts should be clean and free of organic residue. To verify, observe whether deionized water sheets or beads on the flat surface of the steel parts. If the water beads, as if it were on a freshly waxed car, then the part is still contaminated, and the cleaning procedure should be repeated. If the water sheets, as on a dirty car, then the part are clean. Alternate drying schemes include blowing any residual water away with filtered oil-free air, or placing the parts in an oven. Still another alternative is to boil the parts in deionized water, and then air drying, using the residual heat of the parts to rapidly vaporize the water from the parts Appendices: Assembly Drawings The following pages contain assembly drawings for the various components of the Cross Beam Ionizer. Page 15 of 19

16 Page 16 of 19

17 Page 17 of 19

18 Page 18 of 19

19 Page 19 of 19

Application Note GA-301E. MBMS for Preformed Ions. Extrel CMS, 575 Epsilon Drive, Pittsburgh, PA I. SAMPLING A CHEMICAL SOUP

Application Note GA-301E. MBMS for Preformed Ions. Extrel CMS, 575 Epsilon Drive, Pittsburgh, PA I. SAMPLING A CHEMICAL SOUP Application Note MBMS for Preformed Ions, 575 Epsilon Drive, Pittsburgh, PA 15238 (Poster Presented at 45th ASMS Conference on Mass Spectrometry, June 1-5, 1997) In order to accurately characterize a plasma

More information

Extrel is widely respected for the quality of mass spectrometer systems that are

Extrel is widely respected for the quality of mass spectrometer systems that are Extrel is widely respected for the quality of mass spectrometer systems that are available to the world's top research scientists. In response to increasing requests for complete turn-key systems built

More information

DEPOSITION OF THIN TiO 2 FILMS BY DC MAGNETRON SPUTTERING METHOD

DEPOSITION OF THIN TiO 2 FILMS BY DC MAGNETRON SPUTTERING METHOD Chapter 4 DEPOSITION OF THIN TiO 2 FILMS BY DC MAGNETRON SPUTTERING METHOD 4.1 INTRODUCTION Sputter deposition process is another old technique being used in modern semiconductor industries. Sputtering

More information

Field Pro Operation and Installation Manual

Field Pro Operation and Installation Manual Field Pro Operation and Installation Manual Xtreme Research Corporation SkyScan Division P.O. Box 336, Port Richey, FL 34673-0336 1-800-732-0665 Table of Contents 1. Installation 3 2. Operation 5 3. Care

More information

MODEL NAME : LLDMWW0-15K*0*A

MODEL NAME : LLDMWW0-15K*0*A Eagle Eye (Outdoor LED Module) Application Note MODEL NAME : LLDMWW0-15K*0*A RoHS Compliant HALOGEN FREE (30)-4022 1 / 16 CONTENTS 1. Product Description 3/16 2. Specifications 2.1. Chromaticity Bins for

More information

Richter Optica. Instructions for Model: S850 Stereo Zoom Microscope

Richter Optica. Instructions for Model: S850 Stereo Zoom Microscope Richter Optica info@richter-optica.com Instructions for Model: S850 Stereo Zoom Microscope Microscope Head Focus Knob Stage Clips Zoom Knob C-Mount Adapter Eyepiece Focusing Holder Focusing Holder Set

More information

Red and Green Dot Sight FF26002 USER MANUAL

Red and Green Dot Sight FF26002 USER MANUAL Red and Green Dot Sight FF26002 USER MANUAL The Firefield brand has recently launched with products designed to maximize every intense moment. Originally designed for consumers who need products to hold

More information

Lab 5 - ELECTRON CHARGE-TO-MASS RATIO

Lab 5 - ELECTRON CHARGE-TO-MASS RATIO 79 Name Date Partners OBJECTIVES OVERVIEW Lab 5 - ELECTRON CHARGE-TO-MASS RATIO To understand how electric and magnetic fields impact an electron beam To experimentally determine the electron charge-to-mass

More information

Lab 5 - ELECTRON CHARGE-TO-MASS RATIO

Lab 5 - ELECTRON CHARGE-TO-MASS RATIO 81 Name Date Partners Lab 5 - ELECTRON CHARGE-TO-MASS RATIO OBJECTIVES To understand how electric and magnetic fields impact an electron beam To experimentally determine the electron charge-to-mass ratio

More information

Courtesy of ESS and TheRGA web pages part of a series of application and theory notes for public use which are provided free of charge by ESS.

Courtesy of ESS and TheRGA web pages part of a series of application and theory notes for public use which are provided free of charge by ESS. ESS The RGA freenotes Theory page 1 of 14 RGA Theory Notes Courtesy of ESS and TheRGA web pages part of a series of application and theory notes for public use which are provided free of charge by ESS.

More information

Electron Microscopy Sciences INSTRUCTION MANUAL. Stereo Microscopes Non-illuminated Stands

Electron Microscopy Sciences INSTRUCTION MANUAL. Stereo Microscopes Non-illuminated Stands Electron Microscopy Sciences 1 INSTRUCTION MANUAL Stereo Microscopes Non-illuminated Stands Model GL7-207: Binocular, 6.5:1 Zoom Ratio 10X to 65X, smooth ball bearing construction and Model GL7-307: Trinocular,

More information

6.5 Optical-Coating-Deposition Technologies

6.5 Optical-Coating-Deposition Technologies 92 Chapter 6 6.5 Optical-Coating-Deposition Technologies The coating process takes place in an evaporation chamber with a fully controlled system for the specified requirements. Typical systems are depicted

More information

symphony Reference Electrodes

symphony Reference Electrodes DOC022.53.80322 symphony Reference Electrodes 07/2012, Edition 1 User Manual Table of contents Safety information on page 3 Preparation for use on page 4 Specifications on page 3 Measurement on page 5

More information

Peltier Application Note

Peltier Application Note Peltier Application Note Early 19th century scientists, Thomas Seebeck and Jean Peltier, first discovered the phenomena that are the basis for today s thermoelectric industry. Seebeck found that if you

More information

Lab 6 - Electron Charge-To-Mass Ratio

Lab 6 - Electron Charge-To-Mass Ratio Lab 6 Electron Charge-To-Mass Ratio L6-1 Name Date Partners Lab 6 - Electron Charge-To-Mass Ratio OBJECTIVES To understand how electric and magnetic fields impact an electron beam To experimentally determine

More information

National Optical & Scientific Instrument Inc Tri-County Parkway Schertz, Texas Phone (210) Fax (210)

National Optical & Scientific Instrument Inc Tri-County Parkway Schertz, Texas Phone (210) Fax (210) National Optical & Scientific Instrument Inc. 6508 Tri-County Parkway Schertz, Texas 78154 Phone (210) 590-9010 Fax (210) 590-1104 INSTRUCTIONS FOR SHOP MICROSCOPES MODEL NUMBERS 186 187 188 189 National

More information

Assembly Instructions for the 1-Wire Weather Station V2.0/V3.0

Assembly Instructions for the 1-Wire Weather Station V2.0/V3.0 Assembly Instructions for the 1-Wire Weather Station V2.0/V3.0 Tools and Supplies Required (not included): Phillips screwdriver 3/8" wrench Drill with 5/32" bit "U" type mounting bracket (i.e., part number

More information

One-Year Limited Warranty

One-Year Limited Warranty INDEX Product overview...3 Installing the batteries...4 Mounting the Rifle Scope...5 Operation...6 Windage and Elevation adjustments...7-8 Infrared Illumination...8 Focusing...9 Power display & battery

More information

SPECIFICATION SHEET : FHS2-UNV-36L

SPECIFICATION SHEET : FHS2-UNV-36L SPECIFICATION SHEET : FHS2-UNV-36L This Is An Original Product From Fulham Co., Inc Description : For Back-up Lighting This driver will operate constant current LED arrays with a working voltage between

More information

ENSC387: Introduction to Electromechanical Sensors and Actuators LAB 3: USING STRAIN GAUGES TO FIND POISSON S RATIO AND YOUNG S MODULUS

ENSC387: Introduction to Electromechanical Sensors and Actuators LAB 3: USING STRAIN GAUGES TO FIND POISSON S RATIO AND YOUNG S MODULUS ENSC387: Introduction to Electromechanical Sensors and Actuators LAB 3: USING STRAIN GAUGES TO FIND POISSON S RATIO AND YOUNG S MODULUS 1 Introduction... 3 2 Objective... 3 3 Supplies... 3 4 Theory...

More information

Quick Start Guide. The ieq45 GoTo German Equatorial Mount # 8000C

Quick Start Guide. The ieq45 GoTo German Equatorial Mount # 8000C Quick Start Guide The ieq45 GoTo German Equatorial Mount # 8000C PACKAGE CONTENTS Telescope Mount (with built-in GPS) 3.5 Vixen type dovetail saddle (installed on the mount) 8 Losmandy-D type dovetail

More information

Lab 6 - ELECTRON CHARGE-TO-MASS RATIO

Lab 6 - ELECTRON CHARGE-TO-MASS RATIO 101 Name Date Partners OBJECTIVES OVERVIEW Lab 6 - ELECTRON CHARGE-TO-MASS RATIO To understand how electric and magnetic fields impact an electron beam To experimentally determine the electron charge-to-mass

More information

ASTRO-PHYSICS, INC. POLAR ALIGNMENT TELESCOPE (PASILL2)

ASTRO-PHYSICS, INC. POLAR ALIGNMENT TELESCOPE (PASILL2) OBJECTIVE LENS ASTRO-PHYSICS, INC. POLAR ALIGNMENT TELESCOPE (PASILL2) This model shipped from January 2001 through July 2002. It fits all 400, 600, 600E, 800, 900 and 1200 models (except the original

More information

Extrel Application Note

Extrel Application Note Extrel Application Note Real-Time Plasma Monitoring and Detection of Trace H 2 O and HF Species in an Argon Based Plasma Jian Wei, 575 Epsilon Drive, Pittsburgh, PA 15238. (Presented at the 191st Electrochemical

More information

A Multi-beamlet Injector for Heavy Ion Fusion: Experiments and Modeling

A Multi-beamlet Injector for Heavy Ion Fusion: Experiments and Modeling A Multi-beamlet Injector for Heavy Ion Fusion: Experiments and Modeling G.A. Westenskow, D.P. Grote; LLNL J.W. Kwan, F. Bieniosek; LBNL PAC07 - FRYAB01 Albuquerque, New Mexico June 29, 2007 This work has

More information

product manual H-4204 Proving Ring Penetrometer

product manual H-4204 Proving Ring Penetrometer 05.09 product manual H-4204 Proving Ring Penetrometer nnmm Handle Proving Ring Extension Rod Coupler Penetration Rod Cone Figure #1 General Information The Proving Ring Penetrometer is a cone type of penetrometer

More information

ED 701 General Industry Pressure Transmitter

ED 701 General Industry Pressure Transmitter ED 701 General Industry Pressure Transmitter Standard industrial process connections Complete range of electrical connections 4... 20 ma and Voltage outputs Accuracy: 0.1%, 0.2% and 0.4% FS Quick response

More information

Vacuum Chambers. Type DK /DK /DK

Vacuum Chambers. Type DK /DK /DK Vacuum Chambers Type DK 020.010/DK 070.010/DK 050.010 Tel: (609) 924-3011 Fax (609) 924-3018 www.princetonscientific.com Email: info@princetonscientific.com Vacuum Chambers Application: Vacuum chambers

More information

Identification Number

Identification Number Identification Number The specification of Micro Linear Way LWL is specified by the identification number, which consists of a model code, a size, a part code, a preload symbol, a classification symbol,

More information

Installation and Operation Manual. AllSync Plus Wired Clocks

Installation and Operation Manual. AllSync Plus Wired Clocks and Operation Manual AllSync Plus Wired Clocks Part # H004881 Rev. 4 September 2018 Safety Precautions AllSync Plus Clock & Operation Manual Troubleshooting General Operation Introduction Safety Precautions

More information

THE LOSMANDY G-11 MOUNT

THE LOSMANDY G-11 MOUNT Checking the parts THE LOSMANDY G-11 MOUNT Depending on which accessories you ordered, your G-11 mount was shipped in four or more boxes. The contents of each box are as follows: Equatorial Mount Adjustable

More information

Mass Spectrometry in MCAL

Mass Spectrometry in MCAL Mass Spectrometry in MCAL Two systems: GC-MS, LC-MS GC seperates small, volatile, non-polar material MS is detection devise (Agilent 320-MS TQ Mass Spectrometer) Full scan monitoring SIM single ion monitoring

More information

IBV Series C Carbon Steel Inverted Bucket Vertical Steam Trap

IBV Series C Carbon Steel Inverted Bucket Vertical Steam Trap Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

IBV Series Z Alloy Steel Inverted Bucket Vertical Steam Trap

IBV Series Z Alloy Steel Inverted Bucket Vertical Steam Trap Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

Defining quality standards for the analysis of solid samples

Defining quality standards for the analysis of solid samples Defining quality standards for the analysis of solid samples Thermo Scientific Element GD Plus Glow Discharge Mass Spectrometer Redefine your quality standards for the elemental analysis of solid samples

More information

S Sapling INSTALLATION MANUAL FOR FIELD SELECTABLE ANALOG CLOCKS SAA SERIES SPECIFICATIONS. advanced time and control systems

S Sapling INSTALLATION MANUAL FOR FIELD SELECTABLE ANALOG CLOCKS SAA SERIES SPECIFICATIONS. advanced time and control systems INSTALLATION MANUAL FOR FIELD SELECTABLE ANALOG CLOCKS SAA SERIES SPECIFICATIONS Time base: 60 Hz (3-wire system) Quartz (2-wire system) Power input: 85 135 VAC / 60 Hz 7 28 VAC / 60 Hz Current consumption:

More information

saxon Instruction Manual saxon Grandeur Brass Telescope High quality optics

saxon Instruction Manual saxon Grandeur Brass Telescope High quality optics saxon High quality optics Instruction Manual saxon Grandeur Brass Telescope WARNING! Do not use the telescope to look at the sun without an appropriate solar filter. Looking at or near the sun can result

More information

HT600 Dat e Code: 2 - HT MW Purchase Date: PLEASE RETAIN THIS INSTRUCTION MANUAL FOR FUTURE REFERENCE. All Rights Reserved

HT600 Dat e Code: 2 - HT MW Purchase Date: PLEASE RETAIN THIS INSTRUCTION MANUAL FOR FUTURE REFERENCE. All Rights Reserved We strive to ensure that our products are of the highest quality and free of manufacturing defects or missing parts. However, if you have any problems with your new product, D O NOT RETURN IT TO THE STORE,

More information

Accelerators. Table Quadrupole magnet

Accelerators. Table Quadrupole magnet Accelerators 2.6 Magnet System 2.6.1 Introduction According to the BEPCII double ring design scheme, a new storage ring will be added in the existing BEPC tunnel. The tasks of the magnet system can be

More information

Agilent 7500a Inductively Coupled Plasma Mass Spectrometer (ICP-MS)

Agilent 7500a Inductively Coupled Plasma Mass Spectrometer (ICP-MS) www.ietltd.com Proudly serving laboratories worldwide since 1979 CALL +1.847.913.0777 for Refurbished & Certified Lab Equipment Agilent 7500a Inductively Coupled Plasma Mass Spectrometer (ICP-MS) The Agilent

More information

Hilti North America Installation Technical Manual Technical Data MI System Version

Hilti North America Installation Technical Manual Technical Data MI System Version MIC-SA-MAH 174671 Hilti North America Installation Technical Manual Technical Data MI System Version 1. 08.017 Terms of common cooperation / Legal disclaimer The product technical data published in these

More information

Quattro Micro - How does it work?

Quattro Micro - How does it work? Quattro Micro - How does it work? 1 Introduction This document is designed to familiarise you with the principles behind how the Quattro Micro works. The level of this document is designed as Level One

More information

RF Power Feed-Through Capacitors with Conductor Rod, Class 1 Ceramic

RF Power Feed-Through Capacitors with Conductor Rod, Class 1 Ceramic DB 030088, DB 03000 RF Power Feed-Through Capacitors with Conductor Rod, Class Ceramic FEATURES Small size Geometry minimizes inductance Wide range of capacitance values APPLICATIONS Filtering purposes

More information

Analog Technologies. ATEC1 49 Circular TEC Modules

Analog Technologies. ATEC1 49 Circular TEC Modules Figure 1.1. The Photo of Actual Sealed Figure 1.2. The Photo of Actual Sealed FEATURES Circular shape with a center hole High Maxim Voltage/Current Ratio: 5.5 V / 3A Long Life Time APPLICATIONS Stabilize

More information

GS-IR 8816 Series Infrared Thermometer

GS-IR 8816 Series Infrared Thermometer GS-IR 8816 Series Infrared Thermometer Objects having temperatures above absolute zero radiate infrared energy all the time. This infrared energy has a certain functional relations with the surface temperature

More information

Rotary modules.

Rotary modules. Rotary modules www.comoso.com www.comoso.com Rotary modules ROTARY MODULES Series Size Page Rotary modules RM swivel unit 156 RM 08 160 RM 10 162 RM 12 164 RM 15 168 RM 21 172 RM rotor 176 RM 50 180 RM

More information

Measuring Ammonia in Water and Wastewater using the Thermo Scientific Orion Dual Star ph/ise Meter

Measuring Ammonia in Water and Wastewater using the Thermo Scientific Orion Dual Star ph/ise Meter Measuring Ammonia in Water and Wastewater using the Thermo Scientific Orion Dual Star ph/ise Meter Water and Lab Products, Thermo Fisher Scientific Technical Note 505 Key Words Thermo Scientific Orion

More information

AIR PREPARATION. ELECTRONICALLY CONTROLLED PRESSURE REGULATING VALVE (PROPORTIONAL PRESSURE REGULATING VALVE) SERIES control

AIR PREPARATION. ELECTRONICALLY CONTROLLED PRESSURE REGULATING VALVE (PROPORTIONAL PRESSURE REGULATING VALVE) SERIES control AIR PREPARATION ELECTRONICALLY CONTROLLED PRESSRE REGLATING ALE (PROPORTIONAL PRESSRE REGLATING ALE) SERIES control Description Abb. Port size Recommended Type Data Sheet No. flow (l/min)* airfit tecno

More information

RADIATION-METER TM-91/TM-92

RADIATION-METER TM-91/TM-92 RADIATION-METER TM-91/TM-92 User s Manual EN 1 / 16 CONTENTS 1. introduction... 3 2. Safety Precaution... 4 3. Specification... 6 4. Identifying parts... 7 5. Operation Procedure... 8 6. Battery Replacement...

More information

COMMODORE BRASS TELESCOPE ZHUMELL COMMODORE BRASS TELESCOPE

COMMODORE BRASS TELESCOPE ZHUMELL COMMODORE BRASS TELESCOPE 3 0 15 15 E OWNER S MANUAL COMMODORE BRASS TELESCOPE ZHUMELL COMMODORE BRASS TELESCOPE 5 W 60 W 30 W 45 W Zhumell customers know that there are plenty of ways to experience the world. They also understand

More information

Experiment C-15 Distillation - part 1

Experiment C-15 Distillation - part 1 1 Experiment C-15 Distillation - part 1 Objectives To learn about the three classical phases of matter, phase changes, and heating and cooling curves. To investigate the technique of distillation and to

More information

TEST METHOD FOR STILL- AND FORCED-AIR JUNCTION-TO- AMBIENT THERMAL RESISTANCE MEASUREMENTS OF INTEGRATED CIRCUIT PACKAGES

TEST METHOD FOR STILL- AND FORCED-AIR JUNCTION-TO- AMBIENT THERMAL RESISTANCE MEASUREMENTS OF INTEGRATED CIRCUIT PACKAGES SEMI G38-0996 N/A SEMI 1987, 1996 TEST METHOD FOR STILL- AND FORCED-AIR JUNCTION-TO- AMBIENT THERMAL RESISTANCE MEASUREMENTS OF INTEGRATED CIRCUIT PACKAGES 1 Purpose The purpose of this test is to determine

More information

UPGRADE AND COMMISSIONING OF THE PIAVE-ALPI ECR INJECTOR AT LNL

UPGRADE AND COMMISSIONING OF THE PIAVE-ALPI ECR INJECTOR AT LNL UPGRADE AND COMMISSIONING OF THE PIAVE-ALPI ECR INJECTOR AT LNL A. Galatà, M. Sattin, L. Bertazzo, L. Boscagli, S. Contran, A. Dainese, A. Lombardi, D. Maniero, M. Poggi, F. Scarpa, A. Facco, INFN-LNL,

More information

A Complex Example. Geometry Files Reference Complex Example. Introduction. Warning! Background

A Complex Example. Geometry Files Reference Complex Example. Introduction. Warning! Background A Complex Example Introduction The following material traces the development of the extraction optics for our group s high sample temperature mass spectrometer. This serves as an example of how a complex

More information

QPR No. 68 RADIO PHYSICS I. PHYSICAL ELECTRONICS. Prof. W. B. Nottingham J. L. Coggins B. L. Blackford L. E. Sprague RESEARCH OBJECTIVES

QPR No. 68 RADIO PHYSICS I. PHYSICAL ELECTRONICS. Prof. W. B. Nottingham J. L. Coggins B. L. Blackford L. E. Sprague RESEARCH OBJECTIVES RADIO PHYSICS I. PHYSICAL ELECTRONICS RESEARCH OBJECTIVES Prof. W. B. Nottingham J. L. Coggins B. L. Blackford L. E. Sprague 1. Theory of Energy Conversion Electronics The effectiveness of energy conversion

More information

INSTRUCTION MANUAL Milwaukee Refractometer MA881 Refractometer for Invert Sugar Measurements

INSTRUCTION MANUAL Milwaukee Refractometer MA881 Refractometer for Invert Sugar Measurements www.milwaukeeinst.com INSTRUCTION MANUAL Milwaukee Refractometer MA881 Refractometer for Invert Sugar Measurements www.milwaukeeinst.com 1 Instruction Manual MA881 Refractometer for Invert Sugar Measurements

More information

Agilent G3212 GC-APCI Source

Agilent G3212 GC-APCI Source Agilent G3212 GC-APCI Source Quick Start Guide Where to find information 2 Getting Started 3 Step 1. Start the Data Acquisition program for the GC and the Q-TOF 3 Step 2. Prepare the GC and Q-TOF for data

More information

Model 556X User s Manual. Optical Isolator

Model 556X User s Manual. Optical Isolator Model 556X User s Manual Optical Isolator 550031 Rev. A 2 Is a registered trademark of New Focus Inc. Warranty New Focus, Inc. guarantees its products to be free of defects for one year from the date of

More information

CBRD30CP3 & BOWRD30CP INSTRUCTION MANUAL

CBRD30CP3 & BOWRD30CP INSTRUCTION MANUAL CBRD30CP3 & BOWRD30CP INSTRUCTION MANUAL PROLOGUE Your BSA Illuminated sight is for use on both compound and standard bows. Each version of the BSA illuminated sight has a specific reticle to help maintain

More information

Surface Zeta Potential Cell (ZEN1020)

Surface Zeta Potential Cell (ZEN1020) Surface Zeta Potential Cell (ZEN1020) MAN0483 Issue 1.0 September 2011 English Copyright Malvern Instruments Ltd. 2011 Malvern Instruments makes every effort to ensure that this document is correct. However,

More information

Zetasizer Nano-ZS User Instructions

Zetasizer Nano-ZS User Instructions Zetasizer Nano-ZS User Instructions 1. Activate the instrument computer by logging in to CORAL. If needed, log in to the local instrument computer Username: zetasizer. Password: zetasizer. 2. Instrument

More information

Melton Series. Owners Manual. Lab Centrifuge. Model # s A C, A C, B C, B C, C C, C C, D C, D C

Melton Series. Owners Manual. Lab Centrifuge. Model # s A C, A C, B C, B C, C C, C C, D C, D C Melton Series Owners Manual Lab Centrifuge Model # s A-4-115-C, A-4-220-C, B-4-115-C, B-4-220-C, C-4-115-C, C-4-220-C, D-4-115-C, D-4-220-C Serial Numbers 85500 & Above NOTICE Wire this centrifuge according

More information

USER MANUAL. EZEKIEL 3-30x56. Riflescope. English / Francais / Español / Deutsch

USER MANUAL. EZEKIEL 3-30x56. Riflescope. English / Francais / Español / Deutsch USER MANUAL Riflescope EZEKIEL 3-30x56 English / Francais / Español / Deutsch ABOUT SIGHTMARK Sightmark offers a wide range of products that include red dot scopes, reflex sights, rangefinders, riflescopes,

More information

The Q Machine. 60 cm 198 cm Oven. Plasma. 6 cm 30 cm. 50 cm. Axial. Probe. PUMP End Plate Magnet Coil. Filament Cathode. Radial. Hot Plate.

The Q Machine. 60 cm 198 cm Oven. Plasma. 6 cm 30 cm. 50 cm. Axial. Probe. PUMP End Plate Magnet Coil. Filament Cathode. Radial. Hot Plate. 1 The Q Machine 60 cm 198 cm Oven 50 cm Axial Probe Plasma 6 cm 30 cm PUMP End Plate Magnet Coil Radial Probe Hot Plate Filament Cathode 2 THE Q MACHINE 1. GENERAL CHARACTERISTICS OF A Q MACHINE A Q machine

More information

USER MANUAL REFLEX SIGHT. Ultra Shot Z Series. English / Francais / Español / Deutsch

USER MANUAL REFLEX SIGHT. Ultra Shot Z Series. English / Francais / Español / Deutsch USER MANUAL REFLEX SIGHT Ultra Shot Z Series English / Francais / Español / Deutsch ABOUT SIGHTMARK Sightmark offers a wide range of products that include red dot scopes, reflex sights, rangefinders, riflescopes,

More information

Capacitive Pick-Up Type DB 040

Capacitive Pick-Up Type DB 040 Capacitive Pick-Up Type DB 040 Tel: (609) 924-3011 Fax (609) 924-3018 www.princetonscientific.com Email: info@princetonscientific.com CAPACITIVE PICK-UP PROBE TYPE DB 040 Application: The capacitive pick-up

More information

EMBEDDED-PROBE FLOATING POTENTIAL CHARGE-DISCHARGE MONITOR

EMBEDDED-PROBE FLOATING POTENTIAL CHARGE-DISCHARGE MONITOR EMBEDDED-PROBE FLOATING POTENTIAL CHARGE-DISCHARGE MONITOR Keith G. Balmain University of Toronto Department of Electrical and Computer Engineering 10 King s College Rd Toronto, Ontario M5S 3G4, Canada

More information

The ISIS Penning H - SPS and Diagnostic Developments at RAL

The ISIS Penning H - SPS and Diagnostic Developments at RAL The ISIS Penning H - SPS and Diagnostic Developments at RAL D.C. Faircloth 1, A.P. Letchford 1, J. Pozimski 1+2, M.O. Whitehead 1, T. Wood 1, S. Jolly 2, P. Savage 2, M. Haigh 3, J. Morrison 3, I. Yew

More information

Demonstration 1: Faraday Ice Pail and Charge Production

Demonstration 1: Faraday Ice Pail and Charge Production Osservazioni e Misure Lezioni I e II Laboratorio di Elettromagnetismo Demonstration 1: Faraday Ice Pail and Charge Production Equipment Required: Electrometer (ES-9078) Charge Producers (ES-9057B) Earth

More information

SPECIFICATION SHEET : FHS2-UNV-36L

SPECIFICATION SHEET : FHS2-UNV-36L SPECIFICATION SHEET : FHS2-UNV-36L This Is An Original Product From Fulham Co., Inc Description : Emergency LED Driver For Back-up Lighting This driver will operate constant current LED arrays with a working

More information

Watercooled RF Power Pot Capacitors External Cooling System

Watercooled RF Power Pot Capacitors External Cooling System Watercooled RF Power Pot Capacitors External Cooling System FEATURES High voltage, current, and power ratings Compact design reduces terminal self inductance and permit operation up to higher frequencies

More information

Model 791 Calibration Plate for Tiltmeters and Inclinometers

Model 791 Calibration Plate for Tiltmeters and Inclinometers User s Manual Model 791 Calibration Plate for Tiltmeters and Inclinometers Serial No. Baseline, L Date measured By mm Introduction The Model 791 Calibration Plate is designed for calibrating any tiltmeter

More information

473-SHX Dew Point Mirror

473-SHX Dew Point Mirror Humidity and Temperature Reference Hygrometer For Temperature up to 125 C Precise and stable chilled mirror dew point mirror technology High temperature optical components High temperature sample fan Cable

More information

The Booster has three magnet systems for extraction: Kicker Ke, comprising two identical magnets and power supplies Septum Se

The Booster has three magnet systems for extraction: Kicker Ke, comprising two identical magnets and power supplies Septum Se 3.2.7 Booster Injection and Extraction 3.2.7.1 Overview The Booster has two magnet systems for injection: Septum Si Kicker Ki The Booster has three magnet systems for extraction: Kicker Ke, comprising

More information

ASTRO-PHYSICS, INC. POLAR ALIGNMENT TELESCOPE

ASTRO-PHYSICS, INC. POLAR ALIGNMENT TELESCOPE Polar Alignment Telescope ASTRO-PHYSICS, INC. POLAR ALIGNMENT TELESCOPE This polar axis telescope will help you align your mount with the Celestial Poles. When your mount is properly aligned, your telescope's

More information

PERFORMANCE SPECIFICATION SHEET

PERFORMANCE SPECIFICATION SHEET INCH-POUND MIL-PRF-22885/77F 2 August 2018 SUPERSEDING MIL-PRF-22885/77E 25 April 2013 PERFORMANCE SPECIFICATION SHEET SWITCHES, PUSH BUTTON, ILLUMINATED, 4-LAMP, 0.75 SQUARE, 7.5 AMPERES, AND LOW LEVEL

More information

HS515G-M. PARALOW Circle Dot Sight. User's Manual. Holosun Technologies Inc. Phone: (909) Fax: (909)

HS515G-M. PARALOW Circle Dot Sight. User's Manual. Holosun Technologies Inc. Phone: (909) Fax: (909) HS515G-M PARALOW Circle Dot Sight User's Manual Multi Reticle Holosun Technologies Inc. Phone: (909) 594-2888 Fax: (909) 598-4888 E-mail: info@holosun.com COLOR www.holosun.com PARALOW HS515G-M PARALOW

More information

C4 PLUS RIFLESCOPES User Guide

C4 PLUS RIFLESCOPES User Guide C4 Plus USER GUIDE_Layout 1 7/24/15 2:40 PM Page 1 C4 PLUS RIFLESCOPES User Guide This user guide includes information for the entire C4 Plus riflescope line. Please review thoroughly and pay close attention

More information

The FLUX F 430 with mechanical seal

The FLUX F 430 with mechanical seal The FLUX F 0 with mechanical seal Flexible coupling between motor and pump The pump must be used with many varying liquids, consequently the smallest residual left within the pump is unacceptable. You

More information

INSTRUCTIONS FOR ATTACHING THE NORDIC PLOW TO THE ACTION TRACKCHAIR

INSTRUCTIONS FOR ATTACHING THE NORDIC PLOW TO THE ACTION TRACKCHAIR 1 INSTRUCTIONS FOR ATTACHING THE NORDIC PLOW TO THE ACTION TRACKCHAIR Nordic Auto Plow LLC is pleased to provide a plow blade that can be used with your Action Trackchair year round. We are not affiliated

More information

Type M4 - SON - SO - MS

Type M4 - SON - SO - MS 9. REV. Type M - SON - SO - MS Aircaps Tank venting and water excluding aircaps. For installation on service tank air pipes. Inerted void spaces and ballast tanks In order to maintain inert gas pressure

More information

DHS1900 DHS3000 High Temperature Hand Held Infrareds User Manual

DHS1900 DHS3000 High Temperature Hand Held Infrareds User Manual DHS1900 DHS3000 High Temperature Hand Held Infrareds User Manual WD1063 Rev B Revised 02/23/15 Wahl Instruments Inc. 234 Old Weaverville Road Asheville, NC 28804 Toll Free: 800-421-2853 Phone: 828-658-3131

More information

FLT5A FLT5A. abc. abc. Thermometer User Guide. Thermometer User Guide. Internet:

FLT5A FLT5A. abc. abc. Thermometer User Guide. Thermometer User Guide. Internet: abc instruments international FLT5A Thermometer Land Instruments International Dronfield, S18 1DJ England Telephone: (1246) 417691 Facsimile: (1246) 41585 Email: infrared.sales@landinst.com Internet: www.landinst.com

More information

Installation guide 862 MIT / MIR

Installation guide 862 MIT / MIR Installation guide 862 MIT / MIR in combination with: 864 MTT or 863 MRT or (dual) spot element November 2005 Part no. 4416.232_Rev3 Enraf BV PO Box 812 2600 AV Delft Netherlands Tel. : +31 15 2701 100

More information

Design considerations for linear Paul trap mass spectrometer under development

Design considerations for linear Paul trap mass spectrometer under development Design considerations for linear Paul trap mass spectrometer under development S.Sevugarajan and A.G.Menon Department of Instrumentation, Indian Institute of Science, Bangalore 561, India. Abstract This

More information

Vacuum capacitors overview Capacitor selection guides

Vacuum capacitors overview Capacitor selection guides JENNINGS TECHNOLOGY Vacuum capacitors overview Capacitor selection guides Capacitors by type Capacitor type Vacuum variable Capacity max. (pf) Test voltage / Hz Model no. series Page number 7.,, 1 CVDD-

More information

Measurement method for the proficiency testing program

Measurement method for the proficiency testing program APLAC T088 Appendix Measurement method for the proficiency testing program Introductions This measurement method is prepared for use by the APLAC Proficiency Testing Program Photometric measurement of

More information

Introducing the Agilent 7000A QQQ-MS for GC Sunil Kulkarni Product Specialist Agilent Technologies

Introducing the Agilent 7000A QQQ-MS for GC Sunil Kulkarni Product Specialist Agilent Technologies Introducing the Agilent 7000A QQQ-MS for GC Sunil Kulkarni Product Specialist Agilent Technologies Page 1 Agilent GC/MS Portfolio Smallest footprint, single GC column 5975VL with 6850GC Industry leading

More information

Atomic and nuclear physics

Atomic and nuclear physics Atomic and nuclear physics X-ray physics Physics of the atomic shell LEYBOLD Physics Leaflets Moseley s law and determination of the Rydberg constant P6.3.3.6 Objects of the experiment Measuring the K-absorption

More information

Cover Page. The handle holds various files of this Leiden University dissertation.

Cover Page. The handle   holds various files of this Leiden University dissertation. Cover Page The handle http://hdl.handle.net/1887/44295 holds various files of this Leiden University dissertation. Author: Badan, C. Title: Surface-structure dependence of water-related adsorbates on platinum

More information

Vacuum Pumps. Two general classes exist: Gas transfer physical removal of matter. Mechanical, diffusion, turbomolecular

Vacuum Pumps. Two general classes exist: Gas transfer physical removal of matter. Mechanical, diffusion, turbomolecular Vacuum Technology Vacuum Pumps Two general classes exist: Gas transfer physical removal of matter Mechanical, diffusion, turbomolecular Adsorption entrapment of matter Cryo, sublimation, ion Mechanical

More information

Driveline Components Catalog Center Bearings

Driveline Components Catalog Center Bearings J300P-9A Driveline Components Catalog Bearings Updated 8-30-2013 Page 17, Style 22, Column B: changed Bearing part number 212135-1x from 2.890 to 2.690 NEW! Spicer ХС Bearing lmproved Performance and Maintenance

More information

Altazimuth Mount. Altazimuth Mount

Altazimuth Mount. Altazimuth Mount instruction Manual Orion VersaGo II HD Altazimuth Mount #10104 Orion VersaGo II Altazimuth Mount #10105 #10104 #10105 Providing Exceptional Consumer Optical Products Since 1975 OrionTelescopes.com Customer

More information

Lesson 3. Electric Potential. Capacitors Current Electricity

Lesson 3. Electric Potential. Capacitors Current Electricity Electric Potential Lesson 3 Potential Differences in a Uniform Electric Field Electric Potential and Potential Energy The Millikan Oil-Drop Experiment Capacitors Current Electricity Ohm s Laws Resistance

More information

vacuum analysis plasma diagnostics surface science gas analysis

vacuum analysis plasma diagnostics surface science gas analysis Hiden EQP Systems High Sensitivity Mass and Energy Analysers for Monitoring, Control and Characterisation of Ions, Neutrals and Radicals in Plasma. vacuum analysis surface science gas analysis plasma diagnostics

More information

Assessment of the Azimuthal Homogeneity of the Neutral Gas in a Hall Effect Thruster using Electron Beam Fluorescence

Assessment of the Azimuthal Homogeneity of the Neutral Gas in a Hall Effect Thruster using Electron Beam Fluorescence Assessment of the Azimuthal Homogeneity of the Neutral Gas in a Hall Effect Thruster using Electron Beam Fluorescence IEPC-2015-91059 / ISTS-2015-b-91059 Presented at Joint Conference of 30th International

More information

ULTRA SHOT PLUS - DARK EARTH REFLEX SIGHT SM26008DE

ULTRA SHOT PLUS - DARK EARTH REFLEX SIGHT SM26008DE USER MANUAL ULTRA SHOT PLUS - DARK EARTH REFLEX SIGHT SM26008DE ABOUT SIGHTMARK Sightmark offers a wide range of products that include red-dot sights, reflex sights, riflescopes, laser sights, night vision,

More information

USER MANUAL REFLEX SIGHT. Ultra Shot Plus

USER MANUAL REFLEX SIGHT. Ultra Shot Plus USER MANUAL REFLEX SIGHT Ultra Shot Plus ABOUT SIGHTMARK Sightmark offers a wide range of products that include red dot scopes, reflex sights, rangefinders, riflescopes, laser sights, night vision and

More information

Latest generation testo air velocity & IAQ probes with cable handle. Instruction manual

Latest generation testo air velocity & IAQ probes with cable handle. Instruction manual Latest generation testo air velocity & IAQ probes with cable handle Instruction manual Contents Contents 1 About this document... 5 2 Safety and disposal... 5 3 System description... 6 4 Description of

More information

Hilti North America Installation Technical Manual Technical Data MI System Version

Hilti North America Installation Technical Manual Technical Data MI System Version MIC-S10-AH-L 179517-1 Hilti North America Installation Technical Manual Technical Data MI System Version 1. 08.017 Terms of common cooperation / Legal disclaimer The product technical data published in

More information