TPHIC Series Constant Pressure Inverter Control System
|
|
- Chester Blair
- 5 years ago
- Views:
Transcription
1 TPI Series onstant Inverter ontrol System Power: 0. - P : Up to kg/cm² Flow: Up to L/min : " -" pplications partment buildings, houses, villa water supply, factories, water supply systems, drinking water systems, RO water treatment equipment, supermarkets, motels, SP, etc. Operating onditions. mbient temperature: Max. +0. Liquid temperature: + ~+0. Suitable liquids:potable water or other clean, thin or non-aggressive liquids.. pressure: Lower than the constant pressure setting limit (see page ~) code xample: TP T K S I V x Pump series TP flow rate [m³/h] head [kg/cm²] Stainless steel series I: I inverter series eluxe Number of pumps in parallel Product Features The pump will start smoothly when water is consumed. The inverter controller has a pressure sensor to detect down-stream pressure and adjust the motor speed to keep it at the required psi. onstant and stable pressure control: The pump will maintain a constant operating pressure at the pressure setting. This ensures a stable water supply even though occasionally the output flow is over the capacity. ry-run protection: The pump will automatically shut down to protect against dry running. Once the pump starts to operate, the pressure sensor will automatically detect the pressure limit. utomatic stop when flow stops: The pump will automatically cycle down as water usage decreases. compensation for pipeline leaks: Should the down steam pressure drop due to leaks in the piping system, the microcomputer will detect the pressure loss automatically and operate the pump to maintain the pressure setting limit. Single or parallel unit operation: Parallel operation: When water usage is low, one unit will begin to operate until the water usage increases, when it can no longer handle the required water pressure, the other unit will start functioning in parallel. The duplex unit will switch to single unit operation automatically with the decrease in water demand. Interchangeable operation: When a pump has operated through the preset interval (adjustable at 0- hours) the system will automatically switch to the other unit. This cycle will continue through time. 0
2 TPI Series Performance curves - Single unit.0 /z PRSSUR kg/cm² TK TK TK TK TK TK TK TK 8TK 8TK 8TK TK TK TK TK TK TK TK TK T.K.0 TK TK 8TK TK TK PITY L/min Performance curves - uplex.0 /z PRSSUR kg/cm² TK TK TK TK TK TK TK TK 8TK 8TK 8TK TK TK TK TK TK TK TK TK T.K.0 TK TK 8TK TK TK PITY L/min
3 T/T I Specifications - Single unit Inverter ontroller reaker TPTKI TPTKI TPTKI TPTKI TPTKI Ø Ø Ø Ø Ø 00-0V 00-0V 00-0V 00-0V 00-0V TPTKI TPTKI TPTKI TPTKI TPTKI Ø Ø Ø Ø Ø 00-0V 00-0V 00-0V 00-0V 00-0V ½ ½ ½ ½ ½ ½ ½ ½ ½ ½ Fig. TPT /T - I T: " T: ½" TPTKI TPTKI 0 99 tank (L) Fig TPTKI T: " T: ½" TPTKI TPTKI TPTKIV TPTKIV TPTKIV TPTKIV TPTKIV Fig. TPT /T - IV TPTKI TPTKI T: " T: ½" TPTKI TPTKI TPTKI T: " T: ½" TPTKIV TPTKIV TPTKIV TPTKIV TPTKIV 0 0
4 8T/T I Specifications - Single unit Inverter ontroller reaker TP 8 T KI TP 8 T KI TP 8 T KI TP 8 T KI Ø Ø Ø Ø 00-0V 00-0V 00-0V 00-0V TPT KI TPT KI Ø Ø 00-0V 00-0V TPT KI Fig. TP8T /T - I tank (L) Fig " TP8TKI TP8TKI " TP8TKI TP8TKI TPTKI TPTKI TPTKI 0
5 T/T I Specifications - Single unit Inverter ontroller reaker TPT KI TPT KI TPT KI ½ TPT KI TPT KI 0 0 TPT.KI ½ TPT KI TPT KI 0 80 Fig. TP TKI / TP TKI tank (L) Fig " TPTKI TPTKI TPTKI 8 8 " TPTKI TPTKI TPT.KI TPTKI TPTKI Fig. TP TKI ~ TPTKI Fig. TP T - I 8 8 " " " 8 08 "
6 T/T Ix Specifications - uplex Inverter ontroller reaker TPTKI x TPTKI x TPTKI x TPTKI x TPTKI x x x x x x Ø Ø Ø Ø Ø 00-0V 00-0V 00-0V 00-0V 00-0V TPTKI x TPTKI x TPTKI x TPTKI x TPTKI x x x x x x Ø Ø Ø Ø Ø 00-0V 00-0V 00-0V 00-0V 00-0V ½ ½ ½ ½ ½ tank (L) TPTKI x 0 99 x " TPTKI x TPTKI x TPTKI x 00 x x x 0 T:" 00 T:½" TPTKI x 8 x 80 8 TPTKI x TPTKI x TPTKI x TPTKI x x x x x TPTKI x 9 x
7 8T/T Ix Specifications - uplex Inverter ontroller reaker TP 8 T KI x TP 8 T KI x TP 8 T KI x TP 8 T KI x x x x x Ø Ø Ø Ø 00-0V 00-0V 00-0V 00-0V TPT KI x TPT KI x x x Ø Ø 00-0V 00-0V TPT KI x x.0 0 " tank (L) TP8TKI x. x TP8TKI x x 0 0 TP8TKI x. 0 x " TP8TKI x 9. x TPTKI x. x TPTKI x TPTKI x x x
8 T/T Ix Specifications - uplex Inverter ontroller reaker TPT KI x x TPT KI x x TPT KI x ½ x TPT KI x 0 x TPT KI x 0 x TPT.KI x ½ x. TPT KI x 0 x.0 0 TPT KI x x 00 Fig. TP T - I x 9 tank (L) Fig TPTKI x 8 x (8) 9 8 TPTKI x TPTKI x 8 8 x x TPTKI x 0 8 x 8 TPTKI x 0 8 x 0 Fig. 8 TP T - I x TPT.KI x TPTKI x TPTKI x x x x
TPH Series WALRUS PUMP. Multi-stage Centrifugal Pump. All specifications are subject to change without notice. 014
T Series WLRUS PUMP ll specifications are subject to change without notice. Multistage entrifugal Pump T T pplications The WLRUS T Series is horizontal multistage centrifugal pump, suitable for clean water/liquid
More informationSTATE OF COLORADO DESIGN CRITERIA FOR POTABLE WATER SYSTEMS WATER QUALITY CONTROL DIVISION. Price: $5.00. Revised March 31, 1997
STATE OF COLORADO DESIGN CRITERIA FOR POTABLE WATER SYSTEMS WATER QUALITY CONTROL DIVISION Revised March 31, 1997 Price: $5.00 a. an arrangement where the water pipe to be injected with chlorine enters
More informationIts modular concept allows to build up a ball valve for any degree of automation and any kind of application
Type 2657...59 DN 10 up to 80 mm; Plastic; 2/2 way dvantages/benefits ntegrated pilot valves, position feed-back and limit switches available Customized system solutions with Burkert valves & sensors With
More informationTPH Series 50Hz Multi-stage Centrifugal Pump
WLRUS PUMP T Series Hz Multistage Centrifugal Pump ll specifications are subject to change without notice. 9 T Product data pplications Page Standard mode Page Operation conditions Page Pump construction
More informationTPH. 60Hz. Standard mode TPH 4T 2K. Code TPH 4T 2K S F A H
C US NSF/ANSI TPH Applications: The TPH Series are modernly designed with quiet and high efficient operation pumps, suitable for dependable water transfer, circulating or booster service. -Industrial circulation
More informationDOMESTIC HOT WATER PUMPS WITH FIXED-SPEED MOTOR, 3x400V AP-, AKP- and AEP- series, threaded G1/2 G1 ¼ LOREM IPSUM JE ZULT MAAR 60 HZ.
LOREM IPSUM JE ZULT MAAR HZ m Head m/s m/s m/s m/s m/s Ø m Ø Ø Ø Ø l/s Flow kw Shaft power P Ø m/h Ø 9 Ø Ø kw 9 Total input power P Ø DOMESTIC HOT WATER PUMPS WITH FIXED-SPEED MOTOR, xv AP-, AKP- and AEP-
More informationOverview of Control System Design
Overview of Control System Design General Requirements 1. Safety. It is imperative that industrial plants operate safely so as to promote the well-being of people and equipment within the plant and in
More informationph/o.r.p. probe Type 8619 multicell transmitter/controller General data Measuring range Bürkert ph probe Bürkert O.R.P. probe Medium temperature
ph/o.r.p. probe For many different types of installations and applications Large selection of probe for a wide range of holder Useable for pipe DN15 to DN200 Type 8203 can be combined with... Type 8200
More informationvariable flow dampers
Constant-/ DAU, DAEU, DAVU Summary DAU - manual single flow unit DAEU - motorized twin flow unit DAVU - motorized variable flow unit Diameters Ø 0 Flow range 0 l/s ( m³/h) Pressure range Pa (over the unit)
More informationSINGLE IMPELLER CENTRIFUGAL ELECTRIC PUMPS in cast iron
Cast iron self-priming electric pumps. APPLICATIONS Pressure boosting domestic plants Small-scale irrigation Moving non-aggressive liquids for civil and industrial use Washing plants Washing vehicles CMA-B-C-D
More informationConstant flow damper
Constant flow damper DAU Dimensions B Ød l Description Constant flow damper with manual setting of one flow DAU is a constant flow damper, which facilitates balancing of entilation systems and gies correct
More informationIBV Series C Carbon Steel Inverted Bucket Vertical Steam Trap
Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without
More informationIBV Series Z Alloy Steel Inverted Bucket Vertical Steam Trap
Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without
More informationPRODUCT DATA SHEET MODEL: SUK-0084
PRODUCT DATA SHEET MODEL: SUK-0084 SPECIFICATIONS: MODEL NUMBER: SUK-0084 PUMP DESIGN: Positive displacement 3 chamber diaphragm pump CHECK VALVE: No CAM: 2 MOTOR: 4 Pole Induction VOLTAGE: 230VAC PRESSURE
More information( Single Case Construction )
OVL FLOWMETER Meter Size:,,,, ( Single ase onstruction ) Pocketless Design GENERL SPEIFITION GS.No.GBB--E GENERL The OVL flowmeter is a positive displacement type flowmeter comprising a pair of oval gear
More informationLUCKY STAR ST HELENA BAY EMERGENCY INTERVENTION PLAN
LUCKY STAR ST HELENA BAY EMERGENCY INTERVENTION PLAN WATER CRISIS SEPTEMBER 2017 Abstract The current water crisis in the Western Cape is one of Lucky Star Operations highest risk for business continuity.
More informationCMA - B - C - D - CMR
Cast iron self-priming electric pumps. APPLICATIONS Pressure boosting domestic plants Small-scale irrigation Moving non-aggressive liquids for civil and industrial use Washing plants Washing vehicles CMA-B-C-D
More informationSVH with HYDROVAR (HVL range)
SVH with HYDROVAR (HVL range) SVH-HVL Rev. B Ed.9/1 (EN) SVH SERIES (e-sv WITH HYDROVAR) Background and context For all pumping needs in commercial or residential building and in industry applications,
More informationCartridge Valves Technical Information. Quick reference
Quick reference Contents CPF0... 8. CP600-5... 8. CP60-5... 8. 066 handle kit... 8.5 MP06... 8.6 MP... 8.6 X05-FD0 Traction manifold... 8.9 X05-FD6 Traction manifold... 8.0 X05-FD0 Traction manifold...
More informationCipriani Harrison Valves Corp.
Butterfly Valve pplication Stainless steel hygienic butterfly valves are used in process piping systems for isolation and control. Butterfly valves operate either manually or automatically. Working Principle
More informationPressure Measurement. Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level 2/27
Overview Siemens AG 011 Function s are for measuring the liquid levels in wells, tanks, channels and dams. Diaphragm p Sensor U const. U + (brown) I EM I -1 (blue) 0, U B s are submersible sensors for
More informationContents. Performance Curves/Technical Data. General Data Performance Range Sectional Drawing TPH 2T TPH 4T TPH 8T TPH 12T TPH 25T TPH 50T
Contents General Data Performance Range Sectional Drawing Performance Curves/Technical Data T T T T T 8T T T T T T T 7 9 T Series Multistage Centrifugal Pump Hz Power:.. kw Head: Up to 7M Flow: Up to L/min
More informationIL series. Centrifugal marine IN-LINE pumps
IL series Centrifugal marine IN-LINE pumps DESCRIPTION Vertically built centrifugal IN-LINE pumps are made with standardized DIN-22 parts, with in-line suction and discharge flanges. This arrangement requires
More informationConstant-/variable flow damper
lindab constant -/ariable flow dampers Constant-/ariable flow damper DAU Dimensions B Ød l Description Constant flow damper with manual setting of one flow DAU is a constant flow damper, which facilitates
More informationEVOTRON WET ROTOR ELECTRONIC CIRCULATORS TECHNICAL DATA APPLICATIONS ADVANTAGES
TECNICAL DATA EVOTRON Operating range: from, -, m3/h with head of up to metres. Pumped liquid temperature range: from - C to + C. Working pressure: bar ( kpa). Protection class: IP X. Insulation class:
More information3 Energy Exchange in Turbomachines
3 Energy Exchange in Turbomachines Problem 1 The solved and unsolved examples of this chapter are meant to illustrate the various forms of velocity triangles and the variety of the turbomachines. In addition,
More informationPAA-ANALYZERS PRINCIPLE OF OPERATION
PAA-ANALYZERS PRINCIPLE OF OPERATION The PAA process analyzer comprises a control unit and an analyzing section which includes the reaction chamber and measuring cell, reagent pumps and associated valves
More informationCooling Water Flow Regulator
Temperature controlled, indirectly and directly actuated diaphragm valves / seat valves Port size G 3/8 to G DN 0 to DN 0 ontinuous regulation High accuracy No auxiliary energy required Technical data
More informationPressure Measurement Single-range transmitters for general applications
Siemens AG 07 Overview Function SITRANS LH00 Transmitter for hydrostatic level U const. p U I EM Sensor Connection for auxiliary power supply Vent pipe with humidity filter Protective conductor connection/
More informationDetermining Liquid Capacity 4 th Annual Pipeline Knowledge Retention Chris Sonneborn November 7, 2013
Determining Liquid Capacity 4 th Annual Pipeline Knowledge Retention Chris Sonneborn November 7, 2013 Outline What is important? Liquid Properties Thermal Conditions Hydraulic Gradient Flow Regime in Liquids
More informationFundamental Principles of Process Control
Fundamental Principles of Process Control Motivation for Process Control Safety First: people, environment, equipment The Profit Motive: meeting final product specs minimizing waste production minimizing
More informationVISIMIX TURBULENT. TACKLING SAFETY PROBLEMS OF STIRRED REACTORS AT THE DESIGN STAGE.
VISIMIX TURBULENT. TACKLING SAFETY PROBLEMS OF STIRRED REACTORS AT THE DESIGN STAGE. This example demonstrates usage of the VisiMix software to provide an Inherently Safer Design of the process based on
More informationLABOTRON EXTRACTION & SYNTHESIS 2450 MHz
LABOTRON EXTRACTION & SYNTHESIS 2450 MHz The LABOTRON TM series is the generic name for a ground breaking range of integrated reactor and microwave transmission systems especially designed to carry out
More informationSystem Impact Assessment Addendum #2 Greenfield & St. Clair Energy Centres
IESO_REP_0292 System Impact Assessment Addendum #2 Greenfield & St. lair Energy entres onnection Assessment & Approval Process Issue 3.0 Greenfield Energy entre AA I 2004-167 Applicant: Greenfield Energy
More informationModel Selection 1. Process Valves. Air. Vacuum
Process Valves Model Selection For product specifications such as maximum operating pressure differentials and operating temperature ranges, refer to the relevent pages of each product. Air One-touch fittings
More information2/2-way ball valve with electric rotary actuator, ball valve in plastic, DN 10-50
/way ball valve with electric rotary actuator, ball valve in plastic, N 50 Suitable for aggressive media High flow rate value Actuator with adjustable limit switches Visual position indicator Type 0 can
More informationConductivity sensor for hygienic applications
Conductivity sensor for hygienic applications Type 8221 can be combined with Perfect for demanding applications in the hygienic industry (CIP and SIP compatible) Variants available for usage over a wide
More informationTransmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level
Overview Function s are for measuring the liquid levels in wells, tanks, channels and dams. Sensor Diaphragm p U const. U +2 (brown) I EM I - (blue) 0, U B s are submersible sensors for hydrostatic level
More information2/3 Port Valves for Fluid Control Model Selection 1
/ Port Valves for Control Model Selection Model Selection For product specifications such as maximum operating pressure differentials and operating temperature ranges, refer to the relevent pages of each
More informationSECTION 1 - WHAT IS A BTU METER? BTU's = Flow x ΔT Any ISTEC BTU Meter System consists of the following main components:
SECTION 1 - WHAT IS A BTU METER? ISTEC BTU Meters measure energy usage by multiplying flow rate and temperature difference. As the water (or other liquid) passes through these lines, the multi-wing turbine
More informationKjeltec 2300 Analyzer Unit
Kjeltec 2300 Analyzer Unit Automatic distillation and approved colorimetric titration for analysis of Kjeldahl nitrogen/protein, ammonium- nitrogen, TKN, Direct distillation (DD), volatile acids/ bases
More informationbarmesapumps.com SELF-PRIMING CENTRIFUGAL TRASH PUMP SPECIFICATIONS Series: SH8-U Suction: 8" Discharge: 8" Spherical solids handling: 3"
SELF-PRIMING CENTRIFUGAL TRASH PUMP Series: SH-U Suction: " Discharge: " Spherical solids handling: 3" SIZE BEARING - PUMP END " x " NPT, lbs., female flange. Open single ball, radial load. LIQUID TEMPERATURE
More informationCCS140 and CCS141. Technical Information. Sensors for free chlorine Amperometric, membrane-covered sensors for installation in the CCA250 assembly
Technical Information CCS140 and CCS141 Sensors for free chlorine Amperometric, membrane-covered sensors for installation in the CCA250 assembly Application Oxidising agents such as chlorine or anorganic
More informationInnovative Solutions from the Process Control Professionals
Control Station Innovative Solutions from the Process Control Professionals Software For Process Control Analysis, Tuning & Training Control Station Software For Process Control Analysis, Tuning & Training
More informationOverview of Control System Design
Overview of Control System Design Introduction Degrees of Freedom for Process Control Selection of Controlled, Manipulated, and Measured Variables Process Safety and Process Control 1 General Requirements
More informationVOLUMEC. Valve Position Indicator 5
VOLUMEC Valve Position Indicator 5 2 KRACHT CORP. 8600 S Wilkinson Way Unit A Perrysburg, OH 43551 USA P +1 419 874 1000 F +1 419 874 1006 flowmeters@krachtcorp.com www.krachtcorp.com VOLUMEC Valve Position
More informationModel Selection 1. Process Valves
Process Valves Model Selection For product specifications such as maximum operating pressure differentials and operating temperature ranges, refer to the relevent pages of each product. Air, Inert gas
More informationTurbine Meter TRZ 03 PRODUCT INFORMATION. Reliable Measurement of Gas
Turbine Meter TRZ 0 PRODUCT INFORMATION Reliable Measurement of Gas TURBINE METER TRZ 0 Method of operation, Construction Method of operation The TRZ 0 turbine meter is a flow meter suitable for gas measurement
More informationCALEFFI. Modulating digital controller for heating and cooling. 161 series 01122/08 GB. replaces dp 01122/05
Modulating digital controller for heating and cooling series REGI ERED SI EN ISO 00:000 Cert. n FM UNI EN ISO 00:000 Cert. n 000 0/0 G replaces dp 0/0 Function The controller can be used with three-point
More informationADI 2040 Process Analyzer
ADI 2040 Process Analyzer Multi-purpose wet chemical analysis Multi-purpose Wet Chemical Analysis ADI 2040 The Metrohm Applikon ADI 2040 Process Analyzer is a multipurpose wet chemical analyzer, that has
More informationDirect-operated 2/2-way solenoid valves Type EV210B
Data sheet Direct-operated 2/2-way solenoid valves Type EV20B EV20B covers a wide range of direct-operated 2/2-way solenoid valves for universal use. EV20B is a very robust valve program with high performance
More information2/3 Port Valves for Fluid Control Model Selection 1
/ Port Valves for Control Model Selection Model Selection For product specifications such as maximum operating pressure differentials and operating temperature ranges, refer to the relevent pages of each
More informationLECTURE 6- ENERGY LOSSES IN HYDRAULIC SYSTEMS SELF EVALUATION QUESTIONS AND ANSWERS
LECTURE 6- ENERGY LOSSES IN HYDRAULIC SYSTEMS SELF EVALUATION QUESTIONS AND ANSWERS 1. What is the head loss ( in units of bars) across a 30mm wide open gate valve when oil ( SG=0.9) flow through at a
More informationDevelopment of an organometallic flow chemistry. reaction at pilot plant scale for the manufacture of
Supporting Information Development of an organometallic flow chemistry reaction at pilot plant scale for the manufacture of verubecestat David A. Thaisrivongs*, John R. Naber*, Nicholas J. Rogus, and Glenn
More informationFigure 1 Enlargement of Powdered Activated Carbon by microscope.
Introduction The following is a description of how the Powdered Activated Carbon (PAC) dosing system operates. Firstly an overview of how the Semi Dry Reactor and the purpose of carbon injection is described.
More informationGRUNDFOS DATA BOOKLET MAGNA, UPE. Series 2000 circulator pumps
GRUNDFOS DATA BOOKLET MAGNA, UPE Series circulator pumps Contents Product data MAGNA/UPE 3 Duty range 3 Characteristic features 3 Benefits 3 Applications 3 eating systems 3 Pumped liquids 3 Type key Performance
More informationApplication Your benefits
Technical Information CCS140 and CCS141 Sensors for free chlorine Amperometric, membrane-covered sensors for installation in the CCA250 flow assembly Application Oxidizing agents such as chlorine or anorganic
More informationOptimizing Coagulation with the Streaming Current Meter. Chuck Veal Micrometrix Corp
Optimizing Coagulation with the Streaming Current Meter Chuck Veal Micrometrix Corp Charged Particles Repel Neutral Particles Flocculate Coagulant Particles Al 3+ Monomeric hydrolysis products e.g. Al(OH)
More informationCVE 372 HYDROMECHANICS EXERCISE PROBLEMS
VE 37 HYDROMEHNIS EXERISE PROLEMS 1. pump that has the characteristic curve shown in the accompanying graph is to be installed in the system shown. What will be the discharge of water in the system? Take
More informationBy-Pass. This voltage is proportional to the liquid level (threewire potentiometer circuit). The resistance reading can
" " ' " ' / The magnetic field which is in the ball or cylindrical floats actuates very small reed contacts through the wall of a guide tube and these pick up an uninterrupted measuring-circuit voltage
More informationTECHNICAL MANUAL 820 LX / 910 LX / 1300 LX
TECHNICAL MANUAL 820 LX / 910 LX / 1300 LX LANCER reserves the right to modify, constantly its documentation for its improvement. The values of adjustments indicated in the displays of this manual are
More informationContents. Identification LHC. Horizontal split case pumps. Type key. Identification Type key
Contents dentification Type key Product data ntroduction Applications Features and benefits Performance range pole pole pole Construction Sectional drawing Construction features Test pressure Operating
More informationSMB20, SMB30 Series. UK market only
SMB, SMB3 Series VARIABLE SPEED BOOSTER SETS WITH e-sm DRIVE VERTICAL MULTISTAGE ELECTRIC PUMPS SERIES e-sv SMART HORIZONTAL MULTISTAGE ELECTRIC PUMPS SERIES e-hm SMART UK market only Cod. 1911 Rev. A
More informationSensors for pressure control OsiSense XMLR
Sensors for pressure control LR Catalogue Simply easy! TM Contents Sensors for pressure control LR General presentation........................ pages 00/ and 00/ Presentation..........................................
More informationElement description. Multipass test in compliance ISO Contaminant ISO MTD. A - Microfibre
Style FZ Stainless Steel Pressure filter Technical data element Style In-Line filter: FZ 00-0 FZP 0 FZ 0 FZP 6 FZX 0 Manifold mounting: FZ 0 FZM 0 Max. working pressure: 700 bar Max. working pressure:
More informationDESIGN OF INDIRECT-TRANSFER (RUN-AROUND-COILSYSTEM) HEAT EXCHANGERS
DESIGN OF INDIRECT-TRANSFER (RUN-AROUND-COILSYSTEM) HEAT EXCHANGERS G. VERES and S. BALIKO Institute of Heat- and Systems-Engineering, Technical University, H-1521 Budapest Received December 15, 1983 Presented
More informationTOTAL HEAD, N.P.S.H. AND OTHER CALCULATION EXAMPLES Jacques Chaurette p. eng., June 2003
TOTAL HEAD, N.P.S.H. AND OTHER CALCULATION EXAMPLES Jacques Chaurette p. eng., www.lightmypump.com June 2003 Figure 1 Calculation example flow schematic. Situation Water at 150 F is to be pumped from a
More informationNew Way Porous Gas Bearings as Seals. Bearings Seals
New Way Porous Gas Bearings as Seals Bearings Seals 1 New Way Overview Founded January 1994. Aston, Pa. 15 miles south of Philadelphia 54 employees 35,000 sq ft facility, Environmentally Controlled Precision
More informationINFRARED THERMOMETER Model : TM-959
LED target light, Emissivity adjustment INFRARED THERMOMETER Model : TM-959 Your purchase of this I N F R A R E D THERMOMETER marks a step forward for you into the field of precision measurement. Although
More informationCryogenic and Electrical Test Results of a 30 M HTS Power Cable
Cryogenic and Electrical Test Results of a 3 M HTS Power Cable V. E. Sytnikov 1, V. S. Vysotsky 1, S. S. Fetisov 1, A. A. Nosov 1, Yu.G.Shakaryan 2, V.I.Kochkin 2, A.N.Kiselev 2, Yu.A. Terentyev 2, V.M.Patrikeev
More informationISEmax CAS40D. Technical Information
Technical Information ISEmax CAS40D Online measurement of nutrient parameters Ion-selective electrodes for the continuous measurement of ammonium, nitrate and other ions Application The ion-selective sensor
More informationApplied Fluid Mechanics
Applied Fluid Mechanics 1. The Nature of Fluid and the Study of Fluid Mechanics 2. Viscosity of Fluid 3. Pressure Measurement 4. Forces Due to Static Fluid 5. Buoyancy and Stability 6. Flow of Fluid and
More informationDM70 Hand-Held Dewpoint Meter for Spot-Checking Applications
DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications The Vaisala DRYCAP Hand-Held Dewpoint Meter DM70 offers accurate and fast measurement for industrial dewpoint applications, such as compressed
More informationStudyona Temperature Observer Ofsteel Slabs in Metal Smelting in Steel Milling Production
Studyona Temperature Observer Ofsteel Slabs in Metal Smelting in Steel Milling Production KienTrung Ngo #1, Phuong Chi Nguyen #2, Phuong Thao Do #3 Department of Automation, Faculty of Electrical Engineering,
More informationOperating instructions Magnetic-inductive flow sensor SM6004 SM7004 SM / / 2014
Operating instructions Magnetic-inductive flow sensor SM6004 SM7004 SM8004 80003223 / 00 05 / 2014 Contents 1 Preliminary note...3 1.1 Symbols used...3 2 Safety instructions...4 3 Functions and features...5
More information1/54 Circulation pump, safety valve, expansion vessel
1/54 Circulation pump, safety valve, expansion vessel pressure loss efficiency of pump secured heat output safety valve sizing expansion vessel sizing Circulation pump 2/54 similar principle as for heating
More informationHigh-Pressure Volumetric Analyzer
High-Pressure Volumetric Analyzer High-Pressure Volumetric Analysis HPVA II Benefits Dual free-space measurement for accurate isotherm data Free space can be measured or entered Correction for non-ideality
More informationCompact and low-cost monitoring of conductive liquids. Magnetic-inductive flow metering from ifm.
Flow sensors www.ifm.com/mid Compact and low-cost monitoring of conductive liquids. Magnetic-inductive flow metering from ifm. For industrial applications Volumetric flow sensor efector mid. High-precision
More informationCCS140 and CCS141. Technical Information. Sensors for free chlorine Amperometric, membrane-covered sensors for installation in the CCA250 assembly
Technical Information CCS140 and CCS141 Sensors for free chlorine Amperometric, membrane-covered sensors for installation in the CCA250 assembly Application Oxidising agents such as chlorine or anorganic
More informationOperating instructions Magnetic-inductive flow meter SM6x04 SM7x04 SM8x04
Operating instructions Magnetic-inductive flow meter SM6x04 SM7x04 SM8x04 UK 80223776 / 00 11 / 2018 Contents 1 Preliminary note...3 2 Safety instructions...4 3 Functions and features...4 4 Function...5
More informationOPERATION MANUAL. 3 in 1, IR, Type K/J/R/E/T, Pt 100 ohm THERMOMETER. Model : TM-2000
3 in 1, IR, Type K/J/R/E/T, Pt 100 ohm THERMOMETER Model : TM-2000 Your purchase of this THERMOMETER marks a step forward for you into the field of precision measurement. Although this THERMOMETER is a
More informationNR2 Thermal Overload Relay. 4. Technical Data. 1. General. 2. Type Designation. 3. Features. Item Series No. I/In Operating time Tp Test condition
s elays C US N Thermal Overload elay. General. Certificates: CB,CE, UL, PCT, CC, VDE;. Electric ratings: C 0/0z, V, 0.~;.3 Tripping class: 0;. Mounting version: a. Plug-in: vailable for N-.,, 3, 93, 0;
More informationCoflore Agitated Cell Reactor
Coflore Agitated Cell Reactor Coflore ACR The Coflore ACR is a lab flow reactor developed by AM Technology for studying chemistry in flow and developing scalable continuous processes. Its flexible design
More informationNR2 Thermal Overload Relay
Contactors,, Starters. Type designation N - Current class Design sequence No. N Thermal Overload elay. General. Certificates: CE, KEM, UkrSEPO, GOST, CC, UL;. Electric ratings: C 0/0z, 90V, 0.~30;.3 Tripping
More informationMULTISTAGE CENTRIFUGAL PUMP TPH 2/4/8/12/25/50T. 50Hz. WALRUS PUMP ISO 9001 Certified
MULTISTAGE CENTRIFUGAL PUMP TPH /////T Hz WALRUS PUMP ISO Certified TPH Applications The WALRUS TPH Series is horizontal multistage centrifugal pump, suitable for clean water/liquid without abrasive matters.
More information473-SHX Dew Point Mirror
Humidity and Temperature Reference Hygrometer For Temperature up to 125 C Precise and stable chilled mirror dew point mirror technology High temperature optical components High temperature sample fan Cable
More informationModeling and Model Predictive Control of Nonlinear Hydraulic System
Modeling and Model Predictive Control of Nonlinear Hydraulic System Petr Chalupa, Jakub Novák Department of Process Control, Faculty of Applied Informatics, Tomas Bata University in Zlin, nám. T. G. Masaryka
More informationFlow Switches. Liquid Flow Switches. McDonnell & Miller. Mounting Methods
Liquid Flow Switches The flow of liquids in pipelines plays an important role in industry and commerce. Under most circumstances it is essential to know whether or not there is a flow in a pipeline, and
More informationMIK. Electromagnetic Flowmeter Compact. for conductivity liquids. Range from liquids, acids and caustic solutions:
Electromagnetic Flowmeter Compact for conductivity liquids measuring monitoring analysing MIK Range from liquids, acids and caustic solutions: 0.0-0. 3-700 l/min frequency-, switching-, analogue output
More informationRelative pressure transmitter type 520
Relative pressure transmitter type 520 Pressure range The compact type 520 pressure transmitter is based upon the Huba Control developed thick film technology where the pressure measuring cell is fully
More informationMetal oil filler and air breather filler caps. Bayonet connection. Reservoir holes. TA46 B (Materials)
Metal oil filler and air Series T 46 4 5 6 4 ayonet connection Ø 46 7 8 46 Reservoir holes T46 (Materials) M5 - Cover: Chrome Plated Steel - Filter element: Impregnated paper Polyurethane 64-6 - Flange:
More informationFlow rates to 475 l/min
FMP Maximum pressure 0 bar Flow rates to 7 l/min Technical data PRSSUR FILTR Filter housing (Materials) ead: Cast iron (chemical heat treatment) ousing: Steel (chemical heat treatment) Bypass valve: Brass
More informationPRO-CLEAN STRATIFIED TANK
PO-CLEAN STATIFIED TANK PODUCT DESCIPTION Pro-Clean stratified tank with spherical exchanger connection High-quality, multifunctional stratified tank made of steel (S J) for hot-water operation and domestic
More informationCone differential pressure flow meter. Operating manual WIDE PLUS PRECISION INSTRUMENTS CO., LTD.
Cone differential pressure flow meter Operating manual WIDE PLUS PRECISION INSTRUMENTS CO., LTD. INDEX Introduction 2 Principle Application The characteristics of flow meter Specification Technical features
More informationSTATIC GAS MONITOR Type SGM/DEW Revision A of 20 aprile 2016
APPLICATIONS Moisture monitoring of air or gas (SF6) Suitable for indoor or outdoor Industrial, medical or aerospace fields HIGHLIGHTS High voltage circuit breakers commonly used for distribution and transmission
More informationDescription of operation...5. Installation...7. Choice and selection...8. SMB20, SMB30 Series Electric pump range and characteristics...
SMB, SMB3 Series VARIABLE SPEED BOOSTER SETS WITH e-sm DRIVE VERTICAL MULTISTAGE ELECTRIC PUMPS SERIES e-sv SMART VERTICAL MULTISTAGE MONOLITHIC ELECTRIC PUMPS SERIES VM SMART HORIZONTAL MULTISTAGE ELECTRIC
More informationSolutions for Tutorial 10 Stability Analysis
Solutions for Tutorial 1 Stability Analysis 1.1 In this question, you will analyze the series of three isothermal CSTR s show in Figure 1.1. The model for each reactor is the same at presented in Textbook
More informationv = m / s Thermal Flow Sensors TA with thin-film sensor element Probes Probe Guides Measuring Tubes
Thermal Flow Sensors TA with thin-film sensor element Probes Probe Guides Measuring Tubes Examples of Application Flow measurements also in hazardous locations X zone 0 or zone 1 in clean rooms in air
More informationIntegral V-Cone Flowmeter VD series
TRANSMITTER DIRECTLY MOUNTED! SIMPLE AND EASY INSTALLATION Integral V-Cone Flowmeter VD series OUTLINE VD series Integral V-Cone Flowmeter is a differential pressure type flowmeter. Unlikely to existing
More informationFull Metal Variable Area Flow Meter and Counter
Full Metal Variable rea Flow Meter and Counter for horizontal and vertical mounting measuring monitoring analysing Special versions up to 600 bar Measuring range: 10-100...00-000 L/h water 0.3-3.0...-0
More information