Kjeltec 2300 Analyzer Unit

Size: px
Start display at page:

Download "Kjeltec 2300 Analyzer Unit"

Transcription

1 Kjeltec 2300 Analyzer Unit Automatic distillation and approved colorimetric titration for analysis of Kjeldahl nitrogen/protein, ammonium- nitrogen, TKN, Direct distillation (DD), volatile acids/ bases etc. (Also shown in picture; Tecator Digestor 20 Auto Lift and the Scrubber) Features & Benefits: Automatic distillation procedure, incl. sample dilution, alkali and receiver addition, distillation, titration, calculation, reporting and tube draining. Officially approved colorimetric titration system (AOAC, EPA, DIN, ISO etc) simplifies validation. Alarms for reagent availability to eliminate errors. Accurate dispensing of reagents provides accuracy. Active built-in safety systems for user protection. Steam Addition for Equilibration* (SAfE) feature for safe distilling of tubes with acid/salt cake contents. Automatic tube draining to eliminate handling of hot tubes full of alkali and simplify waste collection. Corrosion-resistant materials to reduce maintenance costs and extend instrument lifetime. Alkali resistant plastic splash head/tube draining vessel for long life-time. Data to LIMS systems, eliminates transcription errors. Software in English, French, Spanish, German, etc. Interchangeable burette for easy switching of titrant strengths. Temperature control on distillate to secure accurate results. Description: The Kjeltec 2300 Analyzer Unit is the ultimate solution for automation in the routine Kjeldahl laboratory and can be preprogrammed for 10 different distillation routines. The unit is dedicated to production of accurate results. GLP routines are supported by a Recovery Test routine and documentation of all events during analysis. An approved colorimetric titration system is used. Accurate bellows pumps and a high-precision refillable burette give long term stability in reagent delivery. A distillate temperature sensor stops the unit if there is a risk of inaccurate results. The Kjeltec 2300 sets new standards in safety for Kjeldahl analysis. The unit has a wide range of safety features; sensors for 1 tube in place, 2 safety door, 3 front hood, 4 reagent level, 5 plus level and 6 overpressure for the steam generator. The SAfE* (Steam Addition for Equilibration) technology improves safety by a mixing procedure, reducing the exothermic reaction between alkali and acid, no need for manual predilution of samples. A fast tube draining system removes the need for handling hot reagents after distillation. The safety door and drip tray can be easily removed for cleaning. Running costs are low through optimized applications. Downtime and service costs are minimized using selected components and a service mode in the software. Surfaces exposed to reagents are made of corrosion-free, chemicalresistant dyed plastic materials. * Patented Dedicated Analytical Solutions

2 Order numbers: Distilling unit, V, Hz comprising: Automatic distilling/titration unit with tube draining and built-in steam generator for deionized water or tap water complete with alkali/ water/ receiver/waste tanks with level sensors, adapters for 100 & 250 ml tubes and a digestion tube for 100 & 250 ml As above but without reagent tanks Optional accessories: For a complete Kjeldahl system a Digestor with appropriate accessories such as Exhaust, Scrubber, test tubes and catalyst tablets should be selected. Details can be found in the separate data sheet Tecator Digestion Systems Printer 230 V, 50 Hz. Complete with printer cable Printer 115 V, 60 Hz. Complete with printer cable Cable for connection of analyzer to a PC Complete set of tanks with level sensors and connection cables. (alkali/water/receiver/waste) Set of tanks without level sensors. (alkali/water/ receiver/waste) Top loaded level sensor for waste tank Top loaded level sensor for reagent tank Adapter for Büchi tubes Flask for titration acid (3,2 l) Burette cpl, 50/60 Hz Kjeltec DD kit for Direct Distillation procedures comprising 12 distillings tubes, stand for tubes and application note Handling device for digestion tubes Performance data at 230 V: Storage capacity: 400 samples Analysis time: 3,5 min at 30 mg N (6,5 min at 200 mg N) Distillation capacity: ~ 40 ml/min Measuring range: 0,1-200 mg N Reproducibility: 1% RSD (including the digestion step) Recovery: > 99,5 % at nitrogen levels between mg N Tube draining: 200 ml in 2 s. Selectable Reagent pump volumes: ml in steps of 10 ml Burette, min volume: 3,9 µl/step Burette, max speed 40 ml/min Delay: s SAfE Patented : 0-15 s Installation requirements: Power supply: V, Hz Power consumption: W Water consumption: 2 l/min at water temp of 30 C (during distillation 1 l/min at water temp of 15 C only) Ambient temperature: max. 40 C Ambient humidity: max. 80 % relative Weight net: 35 kg Dimensions: L D H = cm Drain: For cooling water only *Ordering information: Use the above specified Cat. Nos. together with the text. FOSS Analytical 69, Slangerupgade DK-3400 Hilleroed Denmark Tel.: Fax: info@foss.dk P/N E, Issue 2 GB, Jan 2006

3 Kjeltec 2100 Distillation Unit Simple to use distillation unit for analysis of Kjeldahl nitrogen/protein, ammoniumnitrogen, TKN, Direct distillation (DD), volatile acids/bases etc. (Also shown in picture; Tecator Digestor 20 Auto Lift and the Scrubber) Features & Benefits: Automatic distillation procedure; incl. alkali addition and distillation. Provides ease of use. Official and accurate procedures (AOAC, EPA, DIN, ISO etc) simplify validation. Bellow pumps for dispensing of reagents provides accuracy. Built-in safety systems for user protection. Steam Addition for Equilibration* (SAfE) feature for safe distilling of tubes with acid/salt cake contents. Alkali resistant plastic splash head for long lifetime. Description: The Kjeltec 2100 Distillation Unit provides a simple and reliable solution for safe and semiautomatic distillation. The possibility to pre-program alkali addition and distillation time supports the production of accurate results independent of operator. Accurate bellows pumps give long term stability in reagent delivery. The Kjeltec 2100 Distillation Unit is safe to use. The unit is equipped with sensors for safety door and level/overpressure sensors for the steam generator. The door completely covers the area in front of the operator and the unit can not be operated with the door open. The SAfE* (Steam Addition for Equilibration) technology improves safety by a mixing procedure, reducing the exothermic reaction between alkali and acid during distillation. The drip tray can be easily removed for cleaning. Running costs are low through optimized applications. Downtime and service costs are minimized using selected components. A routine maintenance schedule supports GLP routines. * Patented Dedicated Analytical Solutions

4 Order numbers: Distilling Unit V, Hz Distilling unit with automation of alkali addition and distillation cycle. Built-in steam generator for deionized water or tap water. Complete with alkali tank, a set of 10 receiver flasks, adapters for 100 & 250 ml tubes and digestion tube for 100 & 250 ml Separate feed water system V, 50 Hz Separate feed water system V, 60 Hz Optional accessories: For a complete Kjeldahl system a Digestor with appropriate accessories such as Exhaust, Scrubber, test tubes and catalyst tablets should be selected. Details can be found in the separate data sheet Tecator Digestion Systems Titration unit complete, 50 ml Adapter for Büchi tubes Basket for 12 receiver flasks (250/300 ml) Receiver flasks, 250 ml (set of 10) Kjeltec DD kit for direct distillation (DD) procedure comprising 12 distilling tubes (750 ml), 12 receiver flasks (300 ml), stand for tubes, basket for flasks and application note Handling device for digestion tubes Performance data at 230 V: Distillation time: 4 min at 30 mg N (7 min at 200 mg N) Distillation capacity: ~ 30 ml/min Measuring range: 0,1-200 mg N Reproducibility: 1% RSD (including the digestion step) Recovery: > 99,5 % at nitrogen levels between mg N Reagent pump volumes: ml in steps of 10 ml Delay: 12 s SAfE Patented : 2 s Installation requirements: Power supply: V Hz Power consumption: W Water consumption: 2 l/min at water temp of 30ºC (During distillation 1 l/min at water temp of 15ºC only) Ambient temperature: max. 40ºC Ambient humidity: max. 80 % relative Weight net: 25 kg Dimensions: L D H = cm Drain: For cooling water only *Ordering information: Use the above specified Cat. Nos. together with the text. FOSS Analytical 69, Slangerupgade DK-3400 Hilleroed Denmark Tel.: Fax: info@foss.dk P/N E, Issue 2 GB, Nov 2005

5 Kjeltec 2400/2460 Auto Sampler System Fully automatic distillation for analysis of Kjeldahl nitrogen/protein, ammoniumnitrogen, Direct distillation (DD), volatile acids/bases etc. (Also shown in picture; Tecator Digestor 20 Auto Lift and the Scrubber) Features & Benefits: Automatic distillation procedure, incl. sample dilution, alkali and receiver addition, distillation, titration, calculation, reporting and tube draining. Officially approved colorimetric titration system (AOAC, EPA, DIN, ISO etc) simplifies validation. Fully unattended analysis of 60 samples. Alarms for reagent availability to eliminate errors. Accurate dispensing of reagents improves precision. Active built-in safety systems for user protection. Steam Addition for Equilibration* (SAfE) feature for safe distilling of tubes with acid/salt cake contents. Corrosion-resistant instrument materials. Alkali resistant plastic splash head/tube draining vessel for long life-time. Connection to LIMS and balance eliminates transcription errors. Software in English, French, Spanish, German, etc. Interchangeable burette for easy switching of titrant strengths. Weighing Terminal (option) eliminates sample registration errors and saves time. Description: The Kjeltec 2400 Auto Analyzer Unit and the Kjeltec 2400/2460 Sampler System are the ultimate solutions for automation in the routine Kjeldahl laboratory. The analyser unit is dedicated to production of accurate results. GLP routines are supported by sample ID, LIMS/Balance connection, Recovery Test routines and complete documentation of all events during analysis. Accurate bellows pumps and a high-precision refillable burette give long term stability in reagent delivery. A distillate temperature sensor stops the unit if there is a risk of inaccurate results. The Kjeltec 2400 sets new standards in safety for Kjeldahl analysis; sensors for tube in place, safety door, front hood, sampler door, reagent level, plus level and overpressure for the steam generator. The SAfE* technology reduces the exothermic reaction between alkali and acid. There is no need for manual predilution of samples. A fast tube draining system removes the need for handling hot reagents after distillation. The internal part of the sampler can be flushed with water for cleaning. Running costs are low through optimized applications. Downtime and service costs are minimized using selected components and a service mode in the software. Surfaces exposed to reagents are made of corrosion-free, chemicalresistant dyed plastic materials. * Patented Dedicated Analytical Solutions

6 Order numbers: Kjeltec 2400 Auto Analyzer Unit, V, Hz comprising: Automatic distilling / titration unit with tube draining and built-in steam generator for deionized water or tap water complete with alkali/water/receiver/ waste tanks with level sensors, adaptors for 100 ml & 250 ml tubes and a digestion tube for 100 & 250 ml Same as but without reagent tanks Kjeltec 2400/2460 Auto Sampler System V, Hz comprising: including Kjeltec 2460 Sampler System Kjeltec 2460 Sampler System V, Hz with accessories to convert Kjeltec 2400 into an Auto Sampler System Optional accessories: For a complete Kjeldahl system a Digestor with appropriate accessories such as Exhaust, Scrubber, test tubes and catalyst tablets should be selected. Details can be found in the separate data sheet Tecator Digestion Systems Printer 230 V, 50 Hz. Complete with printer cable Printer 115 V, 60 Hz. Complete with printer cable Cable for connection of analyzer to a PC Weighing terminal incl. 3 m cable Extension cable Weighing terminal 10 m Extension cable Weighing terminal 25 m Complete set of tanks with level sensors and connection cables. (Alkali/water/receiver/waste) Set of tanks without level sensors. (Alkali/water/ receiver/waste) Top loaded level sensor for waste tank Top loaded level sensor for reagent tank Adapter for Büchi tubes Flask for titration acid (3,2 l) Burette cpl, 50/60 Hz Kjeltec DD kit for Direct Distillation procedures comprising 12 distillings tubes, stand for tubes and application note Handling device for digestion tubes Performance data at 230 V: Autosampler capacity: 3 racks with 20 Macro Kjeldahl tubes Storage capacity: 800 samples Analysis time: 3,5 min at 30 mg N (6,5 min at 200 mg N) Distillation capacity: ~ 40 ml/min Measuring range: 0,1-200 mg N Reproducibility: 1% RSD (including the digestion step) Recovery: > 99,5 % at nitrogen levels between mg N Tube draining: 200 ml in 2 s. Selectable Burette, min volume: 3,9 µl/step Burette, max speed: 40 ml/min Delay: s SAfE Patented : 0-15 s Installation requirements: Power supply: V, Hz Tolerable voltage variation: ± 10 % Power consumption: W Water consumption: 2 l/min at water temp of 30 C (during distillation 1 l/min at water temp of 15 C only) Ambient temperature: max. 40 C Ambient humidity: max. 80 % relative Weight net: 35 kg Dimensions: L D H Kjeltec cm Kjeltec cm Drain: For cooling water only *Ordering information: Use the above specified Cat. Nos. together with the text. FOSS Analytical 69, Slangerupgade DK-3400 Hilleroed Denmark Tel.: Fax: info@foss.dk P/N E, Issue 2 GB, Jan 2006

UDK. Distillation Units Series. A Full Range of Solutions for Kjeldahl Distillation LABSOLUTIONS

UDK. Distillation Units Series. A Full Range of Solutions for Kjeldahl Distillation LABSOLUTIONS LABSOLUTIONS UDK Distillation Units Series A Full Range of Solutions for Kjeldahl Distillation ABCD The distillation unit is used to perform nitrogen and protein content analysis according to the Kjeldahl

More information

Application Note No. 191/2015 TKN determination in water and waste water

Application Note No. 191/2015 TKN determination in water and waste water Application Note No. 191/2015 TKN determination in water and waste water KjelDigester K-449, KjelMaster K-375 with KjelSampler K-376: Colorimetric determination of TKN (Total Kjeldahl Nitrogen) in water

More information

Application Note No. 116 / 2013 Nitrogen determination in sodium nitrate

Application Note No. 116 / 2013 Nitrogen determination in sodium nitrate Application Note No. 116 / 2013 Nitrogen determination in sodium nitrate KjelMaster K-375: Determination of nitrogen in sodium nitrate according the the Devarda method 1. Introduction An easy, quick and

More information

SpeedDigester K-436, K-439 / KjelFlex K-360 Nitrogen Determination in Nitrate-Free Fertilizer according to the micro-kjeldahl Method 074/2011

SpeedDigester K-436, K-439 / KjelFlex K-360 Nitrogen Determination in Nitrate-Free Fertilizer according to the micro-kjeldahl Method 074/2011 SpeedDigester K-436, K-439 / KjelFlex K-360 Nitrogen Determination in Nitrate-Free Fertilizer according to the micro-kjeldahl Method 074/2011 074/2011 SpeedDigester K-436 / K-439 KjelFlex K-360 SHORT NOTE

More information

Application Note No. 197/2015 Nitrogen and protein determination in dairy products Nitrogen determination in sodium nitrate

Application Note No. 197/2015 Nitrogen and protein determination in dairy products Nitrogen determination in sodium nitrate Application Note No. 197/2015 Nitrogen and protein determination in dairy products Nitrogen determination in sodium nitrate KjelDigester K-449, KjelMaster K-375 with KjelSampler K-376: Accelerated Nitrogen

More information

Measurement uncertainty: Top down or Bottom up?

Measurement uncertainty: Top down or Bottom up? A White Paper from FOSS Measurement uncertainty: Top down or Bottom up? By Dr. Jürgen Möller P/N 1026582, Issue 1, October 2011 Dedicated Analytical Solutions Measurement uncertainty: Top down or Bottom

More information

UDK. Distillation Units Series. A Full Range of Solutions for Kjeldahl Distillation LABSOLUTIONS

UDK. Distillation Units Series. A Full Range of Solutions for Kjeldahl Distillation LABSOLUTIONS LABSOLUTIONS UDK Distillation Units Series A Full Range of Solutions for Kjeldahl Distillation ABCD The distillation unit is used to perform nitrogen and protein content analysis according to the Kjeldahl

More information

Application Note No. 230/2016

Application Note No. 230/2016 Application Note No. 230/2016 Nitrogen determination in bovine serum albumin KjelDigester K-436, KjelFlex K-360: Comparison of standard-kjeldahl and micro-kjeldahl for nitrogen determination in pharmaceutical

More information

Automatic titrators, TitroMatic

Automatic titrators, TitroMatic 112 TitroMatic These are the fourth generation of CRISON titrators. CRISON has over 25 years experience in this field and knows that, for certain applications, the performance and cost of large titrator

More information

ISEmax CAM40/CAS40. Technical Information

ISEmax CAM40/CAS40. Technical Information Technical Information Online measurement of nutrient parameters Ion-selective electrode system for the continuous measurement of ammonium and nitrate Application The ion-selective electrode system works

More information

1. Introduction. 2. Equipment. 3. Chemicals and Materials

1. Introduction. 2. Equipment. 3. Chemicals and Materials 1. Introduction Nitrogen and protein determination in food and feed are described in numerous standard procedures [1-3]. Therein, the titration specifications vary between boric acid and back titration.

More information

Karl-Fischer Titration the method for determining water

Karl-Fischer Titration the method for determining water Karl-Fischer Titration the method for determining water Quite some experienced analyst will be unpleasantly reminded by the pyridine smell, when hearing the name Karl Fischer. However, modern reagents

More information

Thermo Scientific Orion Star T900 Series Laboratory Titrators. Potentiometric titrators for performing automated ph, redox, or ion titrations

Thermo Scientific Orion Star T900 Series Laboratory Titrators. Potentiometric titrators for performing automated ph, redox, or ion titrations Thermo Scientific Orion Star T900 Series Laboratory Titrators Potentiometric titrators for performing automated ph, redox, or ion titrations Thermo Scientific Orion Star T900 Series Titrators Automate

More information

Compact Titration Compact Titrator G20. One Click Titration Simple & Dependable

Compact Titration Compact Titrator G20. One Click Titration Simple & Dependable Compact Titration Compact Titrator G20 One Click Titration Simple & Dependable Simplicity The Intelligent Helper for Simple Titrations One Click Titration Intuitive method adaptation Accurate results simply

More information

Compact Titration. Compact Titrator G20. One Click Titration Simple & Dependable

Compact Titration. Compact Titrator G20. One Click Titration Simple & Dependable Compact Titration Compact Titrator G20 One Click Titration Simple & Dependable Simplicity The Intelligent Helper for Simple Titrations One Click Titration Intuitive method adaptation Accurate results simply

More information

Application Note No. 310/2018

Application Note No. 310/2018 Application Note No. 310/2018 Nitrogen determination in compound fertilizer according to Devarda KjelFlex K-360 with Devarda Splash Protector, Metrohm Titrino 877 www.buchi.com Quality in your hands 1.

More information

SpeedDigester K-436, K-439 / KjelFlex K-360 Nitrogen Determination in Pharmaceuticals according to the Kjeldahl Method (semi-micro)

SpeedDigester K-436, K-439 / KjelFlex K-360 Nitrogen Determination in Pharmaceuticals according to the Kjeldahl Method (semi-micro) 045/2010 SpeedDigester K-436, K-439 / KjelFlex K-360 Nitrogen Determination in Pharmaceuticals according to the Kjeldahl Method (semi-micro) 045/2010 SpeedDigester K-436 / K-439 KjelFlex K-360 SHORT NOTE

More information

Automatic Potentiometric Titrator

Automatic Potentiometric Titrator Automatic Potentiometric Titrator AT-610 Automatic Potentiometric Titrator Two Different Titrations can be Performed Simultaneously --- Allow for Space-saving. Also, a Karl Fischer Moisture Titrator can

More information

Titrex ACT titrators have been designed to simply and precisely satisfy and perform the widest range of potentiometric titrations: acid-base, redox,

Titrex ACT titrators have been designed to simply and precisely satisfy and perform the widest range of potentiometric titrations: acid-base, redox, Titrex ACT titrators have been designed to simply and precisely satisfy and perform the widest range of potentiometric titrations: acid-base, redox, argentometric, complexometric titrations Compact and

More information

From 1 ppm to 100% Karl Fischer water content determination

From 1 ppm to 100% Karl Fischer water content determination METTLER TOLEDO Karl Fischer Titrators DL39 & DL32 Coulometers DL38 & DL31 Volumeters Oven sample changer Stromboli From 1 ppm to 100% Karl Fischer water content determination Karl Fischer water content

More information

Semi-automatic titrators PH-Burette. A great ph-meter with integrated burette. Incredible price! Infinite possibilities

Semi-automatic titrators PH-Burette. A great ph-meter with integrated burette. Incredible price! Infinite possibilities Semi-automatic titrators PH-Burette. A great ph-meter with integrated burette. Incredible price! Infinite possibilities instruments 5 YEARS G U A R A N T E E Quality at a reasonable price The optimum combination

More information

Easy and reliable KF titrations From 1 ppm to 100%

Easy and reliable KF titrations From 1 ppm to 100% AGC Karl Book Fischer 20% Titrators Cyan Volumetric KF Titrators DL31, DL38 Coulometric KF Titrators DL32, DL39 Oven sample changer Stromboli Easy and reliable KF titrations From 1 ppm to 100% Karl Fischer

More information

BECKMAN COULTER QbD1200 Total Organic Carbon Analyzer Critical Measurements Made Simple

BECKMAN COULTER QbD1200 Total Organic Carbon Analyzer Critical Measurements Made Simple BECKMAN COULTER QbD1200 Total Organic Carbon Analyzer Critical Measurements Made Simple Reliable TOC measurements Stop throwing away your first rep. QbD1200 has virtually eliminated sample-to-sample carryover

More information

DI 3500 Discrete Aoalvzer

DI 3500 Discrete Aoalvzer DI 3500 Discrete Aoalvzer Automated Chemistry and Ion Analysis ':t O+Analytical:!, A World ofsolutions. - Discrete Analysis Efficient Microscale Chemistry Increasingly laboratories are being challenged

More information

SKALAR. your partner in chemistry automation. Primacs SN Protein-Nitrogen Analyzer

SKALAR. your partner in chemistry automation. Primacs SN Protein-Nitrogen Analyzer SKALAR your partner in chemistry automation Primacs SN Protein-Nitrogen Analyzer Applications Skalar has many years of experience developing applications for a variety of industries. Successful integration

More information

Automated Clinical Analyzer

Automated Clinical Analyzer Automated Clinical Analyzer Improved ease of operation and better test efficiency, and provides the optimal solution for routine operations, STAT operation and a broad range of clinical analysis requirements.

More information

JAPAN QUALITY. Automated Clinical Analyzer

JAPAN QUALITY. Automated Clinical Analyzer JAPAN QUALITY Automated Clinical Analyzer Higher test performance and operability with new functions The clinical analyzer in the next stage 1 The best to the requirements for functionality and usability

More information

Level. Automate your processes Automate your lab Innovate with. sensing. EasyPREP. sample handler. Automated Sample Preparation.

Level. Automate your processes Automate your lab Innovate with. sensing. EasyPREP. sample handler. Automated Sample Preparation. Automate your processes Automate your lab Innovate with EasyPREP sample handler Automated Sample Preparation Dispense up to 7 reagents Dilute Samples Aliquote Samples Transfer Samples Normalize Samples

More information

LABOTRON EXTRACTION & SYNTHESIS 2450 MHz

LABOTRON EXTRACTION & SYNTHESIS 2450 MHz LABOTRON EXTRACTION & SYNTHESIS 2450 MHz The LABOTRON TM series is the generic name for a ground breaking range of integrated reactor and microwave transmission systems especially designed to carry out

More information

Automating Wet Chemical Analysis. William Lipps Market Specialist for Water Analyzer Products December 11, 2008

Automating Wet Chemical Analysis. William Lipps Market Specialist for Water Analyzer Products December 11, 2008 Automating Wet Chemical Analysis William Lipps Market Specialist for Water Analyzer Products December 11, 2008 The advantages of automating wet chemical analysis. Save time Decrease cost Improve quality

More information

University Wet Chemistry Analyzer Packages

University Wet Chemistry Analyzer Packages University Wet Chemistry Analyzer Packages University laboratories and public research institutions have a special place in the scientific community. Often they are tasked with undertaking basic research

More information

Nitrogen Determination by Kjeldahl (Block Digestion(

Nitrogen Determination by Kjeldahl (Block Digestion( National Forage Testing Association -Forage Analysis Procedures Nitrogen Determination by Kjeldahl (Block Digestion( Scope : This method is applicable for the determination of nitrogen (N) in all types

More information

Application Note No. 117 / 2013 Ammonia determination in hair dye

Application Note No. 117 / 2013 Ammonia determination in hair dye Application Note No. 117 / 2013 Ammonia determination in hair dye KjelMaster K-375 with KjelSampler K-376: Ammonia determination in hair dye with direct distillation 1. Introduction An easy and reliable

More information

Experiment C-15 Distillation - part 1

Experiment C-15 Distillation - part 1 1 Experiment C-15 Distillation - part 1 Objectives To learn about the three classical phases of matter, phase changes, and heating and cooling curves. To investigate the technique of distillation and to

More information

Technology that counts

Technology that counts Application Note No. 102 Version 1.3 Determination of Sperm Density in Ejaculates from Bulls Application This Application Note describes how sperm cell density in ejaculates from bulls can be determined

More information

data sheet DONATELLO FAST General characteristics Rev. First emission - 01/07/ PRO02 code

data sheet DONATELLO FAST General characteristics Rev. First emission - 01/07/ PRO02 code DONATELLO FAST Automatic floor closed cycle tissue processor for histological specimens Automatic tissue processor for histological specimens DONATELLO FAST code PRO0 RI General characteristics DONATELLO

More information

BOXA-II ON-STREAM X-RAY FLUORESCENCE ANALYZER. Technical Description Version 2 BGRIMM AUTOMATION

BOXA-II ON-STREAM X-RAY FLUORESCENCE ANALYZER. Technical Description Version 2 BGRIMM AUTOMATION BOXA-II ON-STREAM X-RAY FLUORESCENCE ANALYZER Technical Description Version 2 BGRIMM AUTOMATION, South 4th Ring Road West, Beijing, China TEL: +86(10)59069762 Fax: +86(10)68360101 Contents BGRIMM AUTOMATION

More information

Mobile coulometer for water determination anywhere you want

Mobile coulometer for water determination anywhere you want 899 Coulometer Mobile coulometer for water determination anywhere you want Extremely small & compact Maximum flexibility due to independent power supply Automatic start of titration 899 Coulometer the

More information

Analysis of domestic sludge using the Agilent 4200 MP-AES

Analysis of domestic sludge using the Agilent 4200 MP-AES Analysis of domestic sludge using the Agilent 4200 MP-AES Application note Environmental Authors Neli Drvodelic Agilent Technologies, Melbourne, Australia Introduction Managing the treatment and disposal

More information

JAPAN QUALITY. Automated Clinical Analyzer

JAPAN QUALITY. Automated Clinical Analyzer JAPAN QUALITY Automated Clinical Analyzer Higher test performance and operability with new functions The clinical analyzer in the next stage 1 The best to the requirements for functionality and usability

More information

473-SHX Dew Point Mirror

473-SHX Dew Point Mirror Humidity and Temperature Reference Hygrometer For Temperature up to 125 C Precise and stable chilled mirror dew point mirror technology High temperature optical components High temperature sample fan Cable

More information

NEW!! Reliable Chlorine Monitoring. Online Residual Chlorine Monitor. Detailed Specifications. Clean Water through Innovative Technology

NEW!! Reliable Chlorine Monitoring. Online Residual Chlorine Monitor. Detailed Specifications. Clean Water through Innovative Technology Clean Water through Innovative Technology NEW!! Instrument Overview Reliable Chlorine Monitoring HF scientific developed the OnLine Residual Chlorine Monitor specifically for drinking water, wastewater

More information

473 Dew Point Hygrometer

473 Dew Point Hygrometer High Performance Chilled Mirror Hygrometer With Cable Mounted Measuring Heads Highly precise chilled mirror dew point technology Cable mounted dew point and temperature measurement Aspirated and direct

More information

ISEmax CAS40D. Technical Information

ISEmax CAS40D. Technical Information Technical Information ISEmax CAS40D Online measurement of nutrient parameters Ion-selective electrodes for the continuous measurement of ammonium, nitrate and other ions Application The ion-selective sensor

More information

Dr. OligoTM DNA / RNA / OLIGO SYNTHESIZERS

Dr. OligoTM DNA / RNA / OLIGO SYNTHESIZERS Dr. OligoTM DNA / RNA / OLIGO SYNTHESIZERS High Throughput Oligo Synthesis Synthesize Cleave Deprotect Desalt Elute Dr. Oligo TM The Dr. Oligo TM High Throughput Oligo Synthesizer is available in four

More information

GS4000 DATASHEET JUNHO 2013

GS4000 DATASHEET JUNHO 2013 GS4000 DATASHEET JUNHO 2013 www.severntrentservices.com Biochem T70GS4000 Chlorine Dioxide Generator - 2g/day - 10g/h System Advantages Dosage Flexibility The generator produces a chlorine dioxide solution,

More information

Automatic Potentiometric Titrator [AT-710S]

Automatic Potentiometric Titrator [AT-710S] Automatic Potentiometric Titrator [AT-710S] Large color TFT-LCD with a touch panel (8.4-inch) enables easy key entry. Monitoring temperature during titration ensures safe measurements. Features Titrant

More information

Dewpoint Meter Data Sheet / Instructions

Dewpoint Meter Data Sheet / Instructions Paint Test Equipment Dewpoint Meter Data Sheet / Instructions Dewpoint Meter Information ISO 8502-4: Preparation of steel substrates before application of paints and related products. Tests for the assessment

More information

KEM SET. for Beverage. Gas volume Internal gas pressure Air content Oxygen concentration Inside pressure Density Brix

KEM SET. for Beverage. Gas volume Internal gas pressure Air content Oxygen concentration Inside pressure Density Brix Acidity Alkalinity for Beverage Gas volume Internal gas pressure Air content Oxygen concentration Inside pressure Density Brix Vitamin C Ca & Mg Acidity Vitamin C for Ca & Mg Ca Mg Alkalinity A Automatic

More information

рн PRO Controller The device is used to control and regulate ph level in hydroponic systems and water preparing units automatically USER MANUAL

рн PRO Controller The device is used to control and regulate ph level in hydroponic systems and water preparing units automatically USER MANUAL рн PRO Controller The device is used to control and regulate ph level in hydroponic systems and water preparing units automatically Complete Set ph PRO Controller - 1 pcs. ph electrode - 1 pcs. Calibration

More information

Moisture Analyzers.

Moisture Analyzers. Moisture Analyzers MS-70/MX-50 MF-50/ML-50 http://www.aandd.jp Select the best for your applic A&D's Moisture Analyzers MS-70/MX-5 MS-70/MX-5 Fast and uniform heating with halogen lamp and innovative SRA

More information

OPTION. Karl Fischer Moisture Titrator [Volumetric titration] Karl Fischer Moisture Titrator [Coulometric titration]

OPTION. Karl Fischer Moisture Titrator [Volumetric titration] Karl Fischer Moisture Titrator [Coulometric titration] CN073 OPTION Bent-type Sampler for Powder 12-04576 "C" Bent-type Sampler for Powders phi18.5 1/10 Taper Glass Sampler for Light Weight Powder Finger Shaped Sampler 12-04452 12-04184 12-04454 ADP Straight-type

More information

Data Sheet / Instructions. Dewpoint MeterO

Data Sheet / Instructions. Dewpoint MeterO Data Sheet / Instructions Dewpoint MeterO Dewpoint Meter ISO 8502-4: Preparation of steel substrates before application of paints and related products. Tests for the assessment of surface cleanliness.

More information

Quantos GraviPrep. Bye Bye, ml Hello, Quantos

Quantos GraviPrep. Bye Bye, ml Hello, Quantos Quantos GraviPrep Bye Bye, ml Hello, Quantos From Volumetric to Gravimetric 75 Years of the Volumetric Flask Remove the Errors in Sample Preparation History of the Volumetric Flask Volumetric flasks have

More information

SafeN130 Movable Apparatus for Radioactive Noble Gases Removing

SafeN130 Movable Apparatus for Radioactive Noble Gases Removing SafeN130 Movable Apparatus for Radioactive Noble Gases Removing Introduction The movable apparatus for removing radioactive noble gases which is developed from DS SCIENCE INC (Model SafeN130), is a prevention

More information

Agilent G2350A Atomic Emission Detector (AED)

Agilent G2350A Atomic Emission Detector (AED) Agilent G0A Atomic Emission Detector (AED) Specifications Elements Specifications Wavelength Minimum Detectable Selectivity Dynamic Measurement Group Element(s) (nm) Level (pg/sec) Over Carbon Range Compound

More information

SKALAR. your partner in chemistry automation. Primacs SNC Total Carbon and Total Nitrogen Analyzer

SKALAR. your partner in chemistry automation. Primacs SNC Total Carbon and Total Nitrogen Analyzer SKALAR your partner in chemistry automation Primacs SNC Total Carbon and Total Nitrogen Analyzer Applications Measuring Carbon and Nitrogen levels is important in soil, plant, animal feed, food samples,

More information

Automating Wet Chemical Analysis

Automating Wet Chemical Analysis Automating Wet Chemical Analysis Who Should Automate? Anyone looking to improve laboratory efficiency Environmental Agricultural Food and beverage Pharmaceutical Mining Etc. Advantages of Automating Save

More information

Technology that counts

Technology that counts Application Note No. 103 Version 1.2 Determination of Sperm Density in Bull Semen Doses for AI Application This Application Note describes how sperm cell density in bull semen doses for Artificial Insemination

More information

POLYPHOSPHORIC ACID ASSAY

POLYPHOSPHORIC ACID ASSAY POLYPHOSPHORIC ACID ASSAY Introduction This Technical Information Report describes the sampling technique and method of analysis recommended to perform rapid and reliable polyphosphoric acid assays for

More information

PTG-NIR Powder Characterisation System (not yet released for selling to end users)

PTG-NIR Powder Characterisation System (not yet released for selling to end users) Powder Characterisation System - PTG-NIR PTG-NIR Powder Characterisation System (not yet released for selling to end users) The PTG-NIR automatic powder and granule inspection system with integrated NIR

More information

Basic Digestion Principles

Basic Digestion Principles Basic Digestion Principles 1 From Samples to Solutions Direct Analytical Method Solid Sample Problems: Mech. Sample Preparation (Grinding, Sieving, Weighing, Pressing, Polishing,...) Solid Sample Autosampler

More information

Atomic Absorption Spectrometer ZEEnit P series

Atomic Absorption Spectrometer ZEEnit P series Atomic Absorption Spectrometer ZEEnit P series Technical Data ZEEnit series Update 07/2014 OBue 1/ 5 ZEEnit P series Variable high-end AA Spectrometer with Deuterium and Zeeman Background Correction with

More information

KEM SET. for FOOD. Salinity. Brix Density Concentration. Acid Value POV. Water Content

KEM SET. for FOOD. Salinity. Brix Density Concentration. Acid Value POV. Water Content Salinity for FOOD Brix Density Concentration Acid Value POV Water Content Vitamin C Acid Value / POV Salinity Vitamin C for FOOD A Automatic Potentiometric Titrator B Automatic Potentiometric Titrator

More information

Sample Preparation LCW 909. Total Kjeldahl Nitrogen, TKN NB: NEW! LCW 909 GB

Sample Preparation LCW 909. Total Kjeldahl Nitrogen, TKN NB: NEW! LCW 909 GB Principle Organically bound nitrogen is digested by hot fuming sulphuric acid in the presence of catalysts and converted to ammonium, which, after steam distillation, can be determined as so-called Total

More information

Freezing point osmometry

Freezing point osmometry Science Together Made in Germany The KNAUER freezing point osmometer The K-7400S Semi-Micro Osmometer can determine the exact freezing point of aqueous solutions. The osmolality of various samples like

More information

Automated pipetting made easy new ep Motion 5073 family members for perfect PCR set-up and nucleic acids purifi cation or general liquid handling

Automated pipetting made easy new ep Motion 5073 family members for perfect PCR set-up and nucleic acids purifi cation or general liquid handling Ready, Set, Prep Automated pipetting made easy new epmotion 5073 family members for perfect PCR set-up and nucleic acids purification or general liquid handling 2 Eppendorf epmotion Eppendorf epmotion

More information

Reagents - Install/Replace. Select method/sequence. KF Reagent calibration Running KF titration methods. Running SAC sequences

Reagents - Install/Replace. Select method/sequence. KF Reagent calibration Running KF titration methods. Running SAC sequences Short-For t-form Reminders Reagents - Install/Replace Select method/sequence KF Reagent calibration Running KF titration methods Running SAC sequences Maintenance recommendations Storage recommendations

More information

ION CHROMATOGRAPHY SYSTEM S 150

ION CHROMATOGRAPHY SYSTEM S 150 ION CHROMATOGRAPHY SYSTEM S 150 WATER ANALYSIS ENVIRONMENTAL ANALYSIS ANION & CATION ANALYSIS ION CHROMATOGRAPHY IIon Chromatography is an analytical separation technique based on ionic interactions. Dissolved

More information

PURCHASE DIVISION DEPARTMENT QUALITY MANUAL. CPRI Section II -Technical Specification

PURCHASE DIVISION DEPARTMENT QUALITY MANUAL. CPRI   Section II -Technical Specification Revision No. : 02 Dt of Revision : 17.9.2012 Issued by : Q A Section : 0 Topic : FORMAT 6 OF PROCUREMENT PROCEDURE OF CPRI (NON-WORKS) Tender Enquery No : PUR/DMD-33/16-17 Name of the Equipment: Auto Titrator

More information

Ascorbic Acid Titration of Vitamin C Tablets

Ascorbic Acid Titration of Vitamin C Tablets Ascorbic Acid Titration of Vitamin C Tablets Introduction This experiment illustrates how titration, the process of slowly adding one solution to another until the reaction between the two is complete,

More information

IV. EQUIPMENT a. Horiba LA 950 main unit b. Dry sample unit that has a silencer behind it c. Cell slide unit that holds

IV. EQUIPMENT a. Horiba LA 950 main unit b. Dry sample unit that has a silencer behind it c. Cell slide unit that holds STANDARD OPERATING PROCEDURE No of pages 7 No: METH 006 Version: 1 Date: 05-06- 2011 Title: Particle Size Distribution Analysis by Laser Diffraction method with HORIBA LA 950 in wet mode I. SCOPE AND APPLICATION

More information

Nitrogen/Protein determination of infant food by the Thermo Scientific FlashSmart Elemental Analyzer using helium or argon as carrier gases

Nitrogen/Protein determination of infant food by the Thermo Scientific FlashSmart Elemental Analyzer using helium or argon as carrier gases APPLICATION NOTE 42255 Nitrogen/Protein determination of infant food by the Thermo Scientific FlashSmart Elemental Analyzer using helium or argon as carrier gases Authors Dr. Liliana Krotz, Dr. Francesco

More information

CHEMISTRY WORKSTATION. The power of proven quality GIVING YOU PEACE OF MIND

CHEMISTRY WORKSTATION. The power of proven quality GIVING YOU PEACE OF MIND CHEMISTRY WORKSTATION The power of proven quality GIVING YOU PEACE OF MIND The new Vitalab Flexor XL extends the excellent reputation of the Flexor family. With over five thousand Flexor installations

More information

Digital Stored Grain Quality Management. BinMaster Level Controls Lincoln, Nebraska, USA

Digital Stored Grain Quality Management. BinMaster Level Controls Lincoln, Nebraska, USA Digital Stored Grain Quality Management BinMaster Level Controls Lincoln, Nebraska, USA Why monitor stored grain? Early detection protects against losses Reduce shrink to maximize grain weight and profit

More information

ECS8020 ORGANIC ELEMENTAL ANALYZER CHNS-O Analyzer

ECS8020 ORGANIC ELEMENTAL ANALYZER CHNS-O Analyzer ECS8020 ORGANIC ELEMENTAL ANALYZER CHNS-O Analyzer ECS 8020 CHNS-O Analyzer Organic Elemental Analysis ECS 8020 is a C-H-N-S-O Elemental Analyzer Model based on the Dumas combustion method. ECS 8020 is

More information

473 Dew Point Hygrometer

473 Dew Point Hygrometer gh Performance Chilled Hygrometer With Cable Mounted Measuring Heads ghly precise chilled mirror dew point technology Cable mounted dew point and temperature measurement Aspirated and direct insertion

More information

32 Input AC Block I/O Module

32 Input AC Block I/O Module Input AC Module Cat. No. 79-A0 Series B Installation Mount the block I/O module in a vertical (recommended) or horizontal position. Allow sufficient room around the block for cooling air to flow through

More information

LCTech GmbH Chromatographie

LCTech GmbH Chromatographie EVA III - an analytical preparation system for all kinds of applications a new system by LCTech that makes work so much easier Overview of Contents: y Broad Spectrum of Application y Automatisation of

More information

Drug Testing Solutions INDIKO DRUG TESTING ANALYZER. 1 P F

Drug Testing Solutions INDIKO DRUG TESTING ANALYZER. 1  P F Drug Testing Solutions INDIKO DRUG TESTING ANALYZER 1 www.dtpm.ws P. 256-845-1261 F. 888-317-4178 sales@dtpm.ws Overview Indiko Sample oriented random access system for clinical and specialty testing,

More information

Freezing point osmometry

Freezing point osmometry Science Together Made in Germany The KNAUER freezing point osmometer The K-7400S Semi-Micro Osmometer can determine the exact freezing point of aqueous solutions. The osmolality of various samples like

More information

INFORMATION LABORATORY ANALYSIS UV-VIS SPECTROPHOTOMETER DR Simply more DR 5000 UV-VIS Spectrophotometer

INFORMATION LABORATORY ANALYSIS UV-VIS SPECTROPHOTOMETER DR Simply more DR 5000 UV-VIS Spectrophotometer INFORMATION LABORATORY ANALYSIS UV-VIS SPECTROPHOTOMETER DR 5000 Simply more DR 5000 UV-VIS Spectrophotometer DR 5000_UV-VIS SPECTROPHOTOMETER More than a Photometer The DR 5000 UV-VIS Spectrophotometer

More information

SMARTCHEM 140 DIRECT READ DISCRETE ANALYZER FOR SIMPLE AND AUTOMATED CHEMISTRIES

SMARTCHEM 140 DIRECT READ DISCRETE ANALYZER FOR SIMPLE AND AUTOMATED CHEMISTRIES SMARTCHEM 140 DIRECT READ DISCRETE ANALYZER FOR SIMPLE AND AUTOMATED CHEMISTRIES SMARTCHEM 140 FULLY AUTOMATED, DIRECT READ, DISCRETE ANALYZER TO MAXIMIZE PRODUCTIVITY FOR ROUTINE AND SPECIAL CHEMISTRIES,

More information

ADI 2040 Process Analyzer

ADI 2040 Process Analyzer ADI 2040 Process Analyzer Multi-purpose wet chemical analysis Multi-purpose Wet Chemical Analysis ADI 2040 The Metrohm Applikon ADI 2040 Process Analyzer is a multipurpose wet chemical analyzer, that has

More information

Application Note #97 Alkalinity and Hardness by Potentiometric Titration Using TRIS Buffer

Application Note #97 Alkalinity and Hardness by Potentiometric Titration Using TRIS Buffer Application Note #97 Alkalinity and Hardness by Potentiometric Titration Using TRIS Buffer Updated July 2017 Introduction: Alkalinity refers to the acid-neutralizing or buffering capacity of a solution.

More information

Intuitive air velocity and IAQ.

Intuitive air velocity and IAQ. Intuitive air velocity and IAQ. The new combines versatility and maximum convenience. 1 The new air velocity & IAQ measuring instrument: versatility in a compact format. Welcome to a new era: the new combines

More information

Coal - Determination of nitrogen - Semi-micro Kjeldahl method. Kol - Bestämning av kvävehalt - Semimicrometod enligt Kjeldahl

Coal - Determination of nitrogen - Semi-micro Kjeldahl method. Kol - Bestämning av kvävehalt - Semimicrometod enligt Kjeldahl Coal - Determination of nitrogen - Semi-micro Kjeldahl method Kol - Bestämning av kvävehalt - Semimicrometod enligt Kjeldahl The International Standard ISO 333:1996 has the status of a Swedish Standard.

More information

INNOVATIVE ENGINEERING FOR SIMPLE OPERATION

INNOVATIVE ENGINEERING FOR SIMPLE OPERATION THE BEST-SELLING MICROWAVE SYNTHESIS PLATFORM takes another leap forward with Discover SP. This new system has all of the features for which the Discover series is known, plus an enhanced heating capability,

More information

The Importance of Area and Retention Time Precision in Gas Chromatography Technical Note

The Importance of Area and Retention Time Precision in Gas Chromatography Technical Note The Importance of Area and Retention Time Precision in Gas Chromatography Technical Note Abstract Area and retention time are the two primary measurements in gas chromatography. The precision with which

More information

881 Compact IC pro 882 Compact IC plus. Compact ion chromatography for intelligent, reliable and precise analysis

881 Compact IC pro 882 Compact IC plus. Compact ion chromatography for intelligent, reliable and precise analysis 881 Compact IC pro 882 Compact IC plus Compact ion chromatography for intelligent, reliable and precise analysis 881 Compact IC pro and 882 Compact IC plus the compact solution for routine analysis 02

More information

Mask/Reticle Cleaning Systems

Mask/Reticle Cleaning Systems Mask/Reticle Cleaning Systems 3019 Alvin Devane Blvd., Suite 300, Austin, Texas 78741 Ph. 512-385-4552; Fax 512-385-4900 main@nanomaster.com; www.nanomaster.com The LSC-5000 is a state of the art auto

More information

QDTL. Liquid Mass Transfer and Diffusion Coefficient Unit PROCESS DIAGRAM AND UNIT ELEMENTS ALLOCATION. Electronic console

QDTL. Liquid Mass Transfer and Diffusion Coefficient Unit PROCESS DIAGRAM AND UNIT ELEMENTS ALLOCATION. Electronic console Engineering and Technical Teaching Equipment Liquid Mass Transfer and Diffusion Coefficient Unit QDTL Electronic console PROCESS DIAGRAM AND UNIT ELEMENTS ALLOCATION ISO 9001: Quality Management (for Design,

More information

PAA-ANALYZERS PRINCIPLE OF OPERATION

PAA-ANALYZERS PRINCIPLE OF OPERATION PAA-ANALYZERS PRINCIPLE OF OPERATION The PAA process analyzer comprises a control unit and an analyzing section which includes the reaction chamber and measuring cell, reagent pumps and associated valves

More information

Ideal and powerful solution

Ideal and powerful solution Thermo Scientific Indiko Plus Clinical and specialty chemistry system Ideal and powerful solution for operational excellence Enzymes Substrates Electrolytes Specific Proteins Drugs of Abuse Analysis Therapeutic

More information

CCS140 and CCS141. Technical Information. Sensors for free chlorine Amperometric, membrane-covered sensors for installation in the CCA250 assembly

CCS140 and CCS141. Technical Information. Sensors for free chlorine Amperometric, membrane-covered sensors for installation in the CCA250 assembly Technical Information CCS140 and CCS141 Sensors for free chlorine Amperometric, membrane-covered sensors for installation in the CCA250 assembly Application Oxidising agents such as chlorine or anorganic

More information

Mercury Stack Monitor SM-4

Mercury Stack Monitor SM-4 Member of the envea Group Mercury Stack Monitor SM-4 Automatic continuous emission monitor (CEM) for mercury Continuous operation Sample dilution directly at stack - works with virtually any sample matrix

More information

Experimental Procedure

Experimental Procedure Experimental Procedure Overview The ph meter is used in conjunction with a titration apparatus and a standardized sodium hydroxide solution to determine the molar concentration of a weak acid solution

More information

3. Chemical industry. Because of their modular design, the instruments in the TOC-L series can be equipped for any possible measurement

3. Chemical industry. Because of their modular design, the instruments in the TOC-L series can be equipped for any possible measurement 3. Chemical industry The most commonly used compound in the chemical industry is water not only as a solvent in processing, but also as an energy carrier in the cooling or heating cycle. As vast amounts

More information

Level Sensor PanCake PR 6251 and Mounting Kit PR 6051

Level Sensor PanCake PR 6251 and Mounting Kit PR 6051 Level Sensor PanCake PR 6251 and Mounting Kit PR 6051 The space-saving solution for simple applications The sensors of the PR 6251 series have been specially designed for simple weighing of silos and horizontal

More information

RS 1700/1900/2300/2900 High Density Reticle Stockers

RS 1700/1900/2300/2900 High Density Reticle Stockers RS 1700/1900/2300/2900 High Density Reticle Stockers CONTAMINATION CONTROL SOLUTIONS Benefits Secure reticle storage Tec-Cell technology Prolongs the reticle lifetime Fast reticle access time High storage

More information