PRODUCT DATA SHEET MODEL: SUK-0084

Size: px
Start display at page:

Download "PRODUCT DATA SHEET MODEL: SUK-0084"

Transcription

1 PRODUCT DATA SHEET MODEL: SUK-0084 SPECIFICATIONS: MODEL NUMBER: SUK-0084 PUMP DESIGN: Positive displacement 3 chamber diaphragm pump CHECK VALVE: No CAM: 2 MOTOR: 4 Pole Induction VOLTAGE: 230VAC PRESSURE SWITCH: No LIQUID TEMPERATURE: <180 F (82 C) PRIME: >4,9 ft (1,5m) PORTS: 3/8 18NPT-F MATERIAL OF CONSTRUCTION: PLASTICS- Nylon VALVES- EPDM DIAPHRAGM- Santoprene FASTENERS- Stainless Steel NET WEIGHT: 2,9kg DUTY CYCLE: Continuous TYPICAL APPLICATIONS: Industrial DIMENSIONS: Nominal dimensions shown PENTAIR WATER BELGIUM BVBA ISSUE: ODL

2 TYPICAL PERFORMANCE MODEL: SUK Flow (L/min) Current (A) Pressure (Bar) L/min A PRESSURE (PSI) BAR FLOW (GPM/LITM) CURRENT (AMPS) / / / / / / / / / / / / ITEM KIT PART NO. DESCRIPTION Pump Head Upper Housing Valve Kit Bypass Diaphragm Regular Drive Assy Regular 6 SF Motor SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE. ALL DATA BASED ON TESTING WITH WATER AT AMBIENT TEMPERATURE PENTAIR WATER BELGIUM bvba Industriepark Wolfstee, Toekomstlaan 30, B-2200 Herentals, Belgium TEL: FAX: shurflo@pentair.com

3 PRODUCT DATA SHEET MODEL: SUK-0092 SPECIFICATIONS: MODEL NUMBER: SUK-0092 PUMP DESIGN: Positive displacement 3 chamber diaphragm pump CHECK VALVE: Yes CAM: 2,5 MOTOR: 4 Pole Induction VOLTAGE: 230VDC PRESSURE SWITCH: Factory set 35PSI Shut-off LIQUID TEMPERATURE: <171 F (77 C) PRIME: >4,9 ft (1,5m) PORTS: 3/8 18NPT-F MATERIAL OF CONSTRUCTION: PLASTICS- Polypropylene VALVES- Viton DIAPHRAGM- Viton FASTENERS- Stainless Steel NET WEIGHT: 2,9kg DUTY CYCLE: Continuous TYPICAL APPLICATIONS: Industrial DIMENSIONS: Nominal dimensions shown PENTAIR WATER BELGIUM BVBA ISSUE: ODL

4 TYPICAL PERFORMANCE MODEL: SUK Flow (L/min) Current (A) L/min A Pressure (Bar) ITEM KIT PART NO. DESCRIPTION Pump Head Pressure Switch Check Valve Upper Housing Valve Kit Standard Diaphragm Regular Drive Assy Regular 8 SF Motor PRESSURE (PSI) BAR FLOW (GPM/LITM) CURRENT (AMPS) / / / / / / SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE. ALL DATA BASED ON TESTING WITH WATER AT AMBIENT TEMPERATURE PENTAIR WATER BELGIUM bvba Industriepark Wolfstee, Toekomstlaan 30, B-2200 Herentals, Belgium TEL: FAX: shurflo@pentair.com

5

6 Pressure (Bar) L/min A

7

8 L/min A Pressure (Bar)

9

10 Pressure (Bar) L/min A

11

12 Pressure (Bar) L/min A

13 PRODUCT DATA SHEET MODEL: SUK-0404 SPECIFICATIONS: MODEL NUMBER: SUK-0404 PUMP DESIGN: Positive displacement 3 chamber diaphragm pump CHECK VALVE: Yes CAM: 2 MOTOR: 2 Pole Induction Motor VOLTAGE: 230VAC PRESSURE SWITCH: Factory set 60PSI Shut-off LIQUID TEMPERATURE: <171 F (77 C) PRIME: >4,9 ft (1,5m) PORTS: 3/8 18 NPT-F MATERIAL OF CONSTRUCTION: PLASTICS- Nylon VALVES- EPDM DIAPHRAGM- Santoprene FASTENERS- Stainless Steel NET WEIGHT: 3,7kg DUTY CYCLE: Continuous TYPICAL APPLICATIONS: Industrial DIMENSIONS: Nominal dimensions shown PENTAIR WATER BELGIUM BVBA ISSUE: ODL

14 Flow (L/min) TYPICAL PERFORMANCE MODEL: SUK Currernt (A) Pressure (Bar) L/min A PRESSURE (PSI) BAR FLOW (GPM/LITM) CURRENT (AMPS) / / / / / / / / ITEM KIT PART NO. DESCRIPTION Pressure Switch Check Valve Upper Housing Valve Kit - Standard Diaphragm - Regular Drive Assy - Regular 7 SF Motor SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE. ALL DATA BASED ON TESTING WITH WATER AT AMBIENT TEMPERATURE PENTAIR WATER BELGIUM bvba Industriepark Wolfstee, Toekomstlaan 30, B-2200 Herentals, Belgium TEL: FAX: shurflo@pentair.com

15 P R ODU C T DA T A SH EET MODEL: SUK-0405 SP EC IF IC A T IONS: MODEL NUMBER: SUK-0405 P UMP DES IG N: P o s itiv e d is p la c e m e n t 3 c h a m b e r d ia p h ra g m p u m p C H EC K V A LV E: N o C A M: 2,5 MOT OR: 2 P o le In d u c tio n V OLT A G E: 2 3 0V D C P RES S URE S W IT C H : N o LIQ UID T EMP ERA T URE: < F (8 2 C ) P RIME: > 4,9 ft (1,5m ) P ORT S : 3 /8 1 8 N P T -F MA T ERIA L OF C ONS T RUC T ION: P LA S T IC S - N y lo n V A LV ES - E P D M DIA P H RA G M- Sa n to p re n e F A S T ENERS - Sta in le s s Ste e l NET W EIG H T : 3,7 k g DUT Y C Y C LE: C o n tin u o u s T Y P IC A L A P P LIC A T IONS : In d u s tria l DIMENSIONS: Nominal dimensions shown P EN T A IR W A T ER B ELG IUM B V B A ISSUE: ODL

16 7.0 TYPICAL PERFORMANCE MODEL: SUK Flow (L/min) Current (A) L/min A Pressure (Bar) PRES S U RE (PS I) B AR FLOW (G PM/LITM) CU RRENT (AMPS ) / / / / / / / / / / / / / / ITEM K IT PART NO. D ES CRIPTION U p p e r H o u s in g V a lv e K it B y p a s s D ia p h ra g m D r iv e S o lid 4 S F M o to r SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE. AL L D ATA BASED ON TESTING WITH WATER AT AM BIENT TEM PER ATUR E PENTAIR WATER BELGIUM bvba In d u s trie p a rk W o lfs te e, T o e k o m s tla a n 30, B H e re n ta ls, B e lg iu m T EL: F A X : e m a il: s h u p e n ta ir.c o m

17 PRODUCT DATA SHEET MODEL: SUK-0406 SPECIFICATIONS: MODEL NUMBER: SUK-0406 PUMP DESIGN: Positive displacement 3 chamber diaphragm pump CHECK VALVE: Yes CAM: 2 MOTOR: 4 Pole Induction VOLTAGE: 230VAC PRESSURE SWITCH: Factory set 50PSI Shut-off LIQUID TEMPERATURE: <180 F (82 C) PRIME: >4,9 ft (1,5m) PORTS: 3/8 18 NPT-F MATERIAL OF CONSTRUCTION: PLASTICS- Nylon VALVES- EPDM DIAPHRAGM- Santoprene FASTENERS- Stainless Steel NET WEIGHT: 2,9kg DUTY CYCLE: Continuous TYPICAL APPLICATIONS: Industrial DIMENSIONS: Nominal dimensions shown PENTAIR WATER BELGIUM BVBA ISSUE: ODL

18 2.10 TYPICAL PERFORMANCE MODEL: SUK Flow (L/min) Current (A) Pressure (Bar) L/min A ITEM KIT PART NO. DESCRIPTION Pressure Switch Check Valve Upper Housing Valve Kit Standard Diaphragm Regular Drive Assy Regular 7 SF Motor PRESSURE (PSI) BAR FLOW (GPM/LITM) CURRENT (AMPS) / / / / / / SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE. ALL DATA BASED ON TESTING WITH WATER AT AMBIENT TEMPERATURE PENTAIR WATER BELGIUM bvba Industriepark Wolfstee, Toekomstlaan 30, B-2200 Herentals, Belgium TEL: FAX: shurflo@pentair.com

19

20 Pressure (Bar)

STEEL PIPE NIPPLE BLACK AND GALVANIZED

STEEL PIPE NIPPLE BLACK AND GALVANIZED Price Sheet Effective August 09, 2018 Supersedes CWN-218 A Member of The Phoenix Forge Group CapProducts LTD. Phone: 519-482-5000 Fax: 519-482-7728 Toll Free: 800-265-5586 www.capproducts.com www.capitolcamco.com

More information

A L A BA M A L A W R E V IE W

A L A BA M A L A W R E V IE W A L A BA M A L A W R E V IE W Volume 52 Fall 2000 Number 1 B E F O R E D I S A B I L I T Y C I V I L R I G HT S : C I V I L W A R P E N S I O N S A N D TH E P O L I T I C S O F D I S A B I L I T Y I N

More information

Pressure Transmitter ED 701

Pressure Transmitter ED 701 Pressure Transmitter ED 701 Hygienic and industrial process connections Zero setting function Accuracy < 0.1% FS Quick response time < 25 ms High long-term stability Excellent repeatability Active compensation

More information

c. What is the average rate of change of f on the interval [, ]? Answer: d. What is a local minimum value of f? Answer: 5 e. On what interval(s) is f

c. What is the average rate of change of f on the interval [, ]? Answer: d. What is a local minimum value of f? Answer: 5 e. On what interval(s) is f Essential Skills Chapter f ( x + h) f ( x ). Simplifying the difference quotient Section. h f ( x + h) f ( x ) Example: For f ( x) = 4x 4 x, find and simplify completely. h Answer: 4 8x 4 h. Finding the

More information

DOMESTIC HOT WATER PUMPS WITH FIXED-SPEED MOTOR, 3x400V AP-, AKP- and AEP- series, threaded G1/2 G1 ¼ LOREM IPSUM JE ZULT MAAR 60 HZ.

DOMESTIC HOT WATER PUMPS WITH FIXED-SPEED MOTOR, 3x400V AP-, AKP- and AEP- series, threaded G1/2 G1 ¼ LOREM IPSUM JE ZULT MAAR 60 HZ. LOREM IPSUM JE ZULT MAAR HZ m Head m/s m/s m/s m/s m/s Ø m Ø Ø Ø Ø l/s Flow kw Shaft power P Ø m/h Ø 9 Ø Ø kw 9 Total input power P Ø DOMESTIC HOT WATER PUMPS WITH FIXED-SPEED MOTOR, xv AP-, AKP- and AEP-

More information

Cartridge Valves Technical Information. Quick reference

Cartridge Valves Technical Information. Quick reference Quick reference Contents CPF0... 8. CP600-5... 8. CP60-5... 8. 066 handle kit... 8.5 MP06... 8.6 MP... 8.6 X05-FD0 Traction manifold... 8.9 X05-FD6 Traction manifold... 8.0 X05-FD0 Traction manifold...

More information

ED 701 General Industry Pressure Transmitter

ED 701 General Industry Pressure Transmitter ED 701 General Industry Pressure Transmitter Standard industrial process connections Complete range of electrical connections 4... 20 ma and Voltage outputs Accuracy: 0.1%, 0.2% and 0.4% FS Quick response

More information

Series P0 Electronic Metering Pump. Specification Sheet and Assembly Details Manual No : 1934, 1843 Rev. : C, D Rev. Date : 6/01, 10/2015

Series P0 Electronic Metering Pump. Specification Sheet and Assembly Details Manual No : 1934, 1843 Rev. : C, D Rev. Date : 6/01, 10/2015 INJECTION CHECK VALVE COUPLING NUT DISCHARGE TUBING 4 FUNCTION VALVE SPACER, E.P.U PUMP HEAD RETURN LINE (PRESSURE RELIEF) METERING PUMP HOUSING STROKE KNOB SUCTION FITTING SUCTION TUBING WEIGHT POWER

More information

Hydraulic Pressure NAH Applications. Features. New generation available - refer to

Hydraulic Pressure NAH Applications. Features. New generation available - refer to NAH 8 Hydraulic Pressure Transmitter New generation available - refer to www.trafag.com/h70 Swiss based Trafag is a leading international supplier of high quality sensors and monitoring instruments for

More information

Flow rates to 750 l/min

Flow rates to 750 l/min FP Maximum pressure 0 bar Flow rates to 70 l/min Technical data Filter housing (Materials) ead: Cast iron (chemical heat treatment) ousing: Steel (chemical heat treatment) Bypass valve: AISI L (FP 0-0)

More information

A wide selection of pipe and orifice sizes is offered. Valves are available with threaded ports in brass and stainless steel.

A wide selection of pipe and orifice sizes is offered. Valves are available with threaded ports in brass and stainless steel. Solenoid Valve Waterhammer-Free, 0- PSI /-Way; NPT - NPT; 0- PSI Advantages/Benefits Type 63 Waterhammer-free Low noise Zero differential pressure ompact design with high flow rates Low maintenance oil

More information

GRUNDFOS DATA BOOKLET MAGNA, UPE. Series 2000 circulator pumps

GRUNDFOS DATA BOOKLET MAGNA, UPE. Series 2000 circulator pumps GRUNDFOS DATA BOOKLET MAGNA, UPE Series circulator pumps Contents Product data MAGNA/UPE 3 Duty range 3 Characteristic features 3 Benefits 3 Applications 3 eating systems 3 Pumped liquids 3 Type key Performance

More information

LES. Single-stage end-suction pumps Identification Type key

LES. Single-stage end-suction pumps Identification Type key Contents Singlestage endsuction pumps Identification Type key Product data Introduction Applications Features and benefits Performance range pole pole 6 pole Construction Sectional drawing Construction

More information

Flow rates to 750 l/min

Flow rates to 750 l/min FP Maximum pressure 0 bar Flow rates to 70 l/min Technical data Filter housing (Materials) ead: Cast iron (chemical heat treatment) ousing: Steel (chemical heat treatment) Bypass valve: AISI L (FP 00-0)

More information

TPH. 60Hz. Standard mode TPH 4T 2K. Code TPH 4T 2K S F A H

TPH. 60Hz. Standard mode TPH 4T 2K. Code TPH 4T 2K S F A H C US NSF/ANSI TPH Applications: The TPH Series are modernly designed with quiet and high efficient operation pumps, suitable for dependable water transfer, circulating or booster service. -Industrial circulation

More information

Suction fi lters. MPA - MPM series. Flow rate up to 875 l/min. Suction fi lters

Suction fi lters. MPA - MPM series. Flow rate up to 875 l/min. Suction fi lters Suction fi lters & MPA MPM series Flow rate up to 87 l/min 7 Suction fi lters FILTER SIZING The correct filter sizing have to be based on the variable pressure drop depending by the application. For example,

More information

ISEmax CAM40/CAS40. Technical Information

ISEmax CAM40/CAS40. Technical Information Technical Information Online measurement of nutrient parameters Ion-selective electrode system for the continuous measurement of ammonium and nitrate Application The ion-selective electrode system works

More information

barmesapumps.com SELF-PRIMING CENTRIFUGAL TRASH PUMP SPECIFICATIONS Series: SH8-U Suction: 8" Discharge: 8" Spherical solids handling: 3"

barmesapumps.com SELF-PRIMING CENTRIFUGAL TRASH PUMP SPECIFICATIONS Series: SH8-U Suction: 8 Discharge: 8 Spherical solids handling: 3 SELF-PRIMING CENTRIFUGAL TRASH PUMP Series: SH-U Suction: " Discharge: " Spherical solids handling: 3" SIZE BEARING - PUMP END " x " NPT, lbs., female flange. Open single ball, radial load. LIQUID TEMPERATURE

More information

Contents. Identification LHC. Horizontal split case pumps. Type key. Identification Type key

Contents. Identification LHC. Horizontal split case pumps. Type key. Identification Type key Contents dentification Type key Product data ntroduction Applications Features and benefits Performance range pole pole pole Construction Sectional drawing Construction features Test pressure Operating

More information

SERIES INLINE FILTERS LMP 210. Maximum pressure 60 bar Maximum flow to l / mi n

SERIES INLINE FILTERS LMP 210. Maximum pressure 60 bar Maximum flow to l / mi n SERIES INLINE FILTERS LMP 0 Maximum pressure 60 bar Maximum flow to 0 0 l / mi n SERIES LMP 0 Working pre s s u re 60 bar Style S Style B B B D.I. D.I. A A Technical data Filter housing ( M a t e r i a

More information

High Pressure fi lters. FMP 039 series. Maximum pressure up to 110 bar - Flow rate up to 80 l/min. High Pressure fi lters

High Pressure fi lters. FMP 039 series. Maximum pressure up to 110 bar - Flow rate up to 80 l/min. High Pressure fi lters High Pressure fi lters FMP 09 series Maximum pressure up to 0 bar Flow rate up to 80 l/min 7 High Pressure fi lters FILTER SIZING The correct filter sizing have to be based on the variable pressure drop

More information

Maximum pressure 420 bar Flow rate to 152 l/min. 560 bar. 140 l/min. Flow rate l/min FMM 050 1/2 1,50 3/4 1,00. Δp bar 0,50 0,00 FHA 051 1,50 1,00

Maximum pressure 420 bar Flow rate to 152 l/min. 560 bar. 140 l/min. Flow rate l/min FMM 050 1/2 1,50 3/4 1,00. Δp bar 0,50 0,00 FHA 051 1,50 1,00 FMM 00 Maximum pressure 0 bar Flow rate to l/min FHA 0 Maximum pressure 60 bar Flow rate to 0 l/min Technical data FMM 00 Filter housing (Materials) Head: Cast iron (chemical heat treatment) Housing: Steel

More information

CV3000 Series. Characterized Insert Control Valves

CV3000 Series. Characterized Insert Control Valves CV3000 Series Characterized Insert Control Valves The CV3000 Series is a v-type control valve for precise control allowing high pressure drop capability with straight-through flow and bubble-tight shut

More information

Field IT 50T Series Transmitters

Field IT 50T Series Transmitters Data Sheet SS/G/A_ Field IT 0T Series Transmitters gauge/absolute pressure transmitter Ranges: -00 to 0000kPa - to 00bar -. to 6000psi Base accuracy : 0.% (BFSL) Chemical Vapour Deposition (CVD) technology

More information

SINGLE IMPELLER CENTRIFUGAL ELECTRIC PUMPS in cast iron

SINGLE IMPELLER CENTRIFUGAL ELECTRIC PUMPS in cast iron Cast iron self-priming electric pumps. APPLICATIONS Pressure boosting domestic plants Small-scale irrigation Moving non-aggressive liquids for civil and industrial use Washing plants Washing vehicles CMA-B-C-D

More information

Its modular concept allows to build up a ball valve for any degree of automation and any kind of application

Its modular concept allows to build up a ball valve for any degree of automation and any kind of application Type 2657...59 DN 10 up to 80 mm; Plastic; 2/2 way dvantages/benefits ntegrated pilot valves, position feed-back and limit switches available Customized system solutions with Burkert valves & sensors With

More information

Fluid Cooling Industrial PF Series

Fluid Cooling Industrial PF Series Fluid Cooling Industrial PF Series 0916 STAINLESS STEEL PLATES CARBON STEEL FRAME Performance Notes Carry bar Gasketed plate style heat exchanger Tie rods Oil to water applications High performance Pressure

More information

GRUNDFOS DATA BOOKLET MAGNA, UPE. Series 2000 circulator pumps

GRUNDFOS DATA BOOKLET MAGNA, UPE. Series 2000 circulator pumps GRUNDFOS DATA BOOKLET Series circulator pumps Contents Product data MAGNA and UPE 3 Duty range 3 Characteristic features 3 Benefits 3 Applications 3 eating systems 3 Pumped liquids 3 Type key Performance

More information

379 Low & Medium Pressure filters. LMD 211 series. Maximum pressure up to 60 bar - Flow rate up to 330 l/min. Low & Medium Pressure fi lters

379 Low & Medium Pressure filters. LMD 211 series. Maximum pressure up to 60 bar - Flow rate up to 330 l/min. Low & Medium Pressure fi lters Low & Medium Pressure fi lters LMD series Maximum pressure up to 60 bar Flow rate up to 0 l/min 79 Low & Medium Pressure filters FILTER SIZING The correct filter sizing have to be based on the variable

More information

EVOTRON WET ROTOR ELECTRONIC CIRCULATORS TECHNICAL DATA APPLICATIONS ADVANTAGES

EVOTRON WET ROTOR ELECTRONIC CIRCULATORS TECHNICAL DATA APPLICATIONS ADVANTAGES TECNICAL DATA EVOTRON Operating range: from, -, m3/h with head of up to metres. Pumped liquid temperature range: from - C to + C. Working pressure: bar ( kpa). Protection class: IP X. Insulation class:

More information

KM-1600SWH KM-1600SRH KM-1600SWH3 KM-1600SRH3

KM-1600SWH KM-1600SRH KM-1600SWH3 KM-1600SRH3 NO. ISSUED: REVISED: 71193 OCT. 2, 2001 JAN. 27, 2003 HOSHIZAKI STACKABLE CRESCENT CUBER MODELS KM-1600SWH KM-1600SRH KM-1600SWH3 KM-1600SRH3 PARTS LIST KM-1600SWH L-0 June, 2001 M-0 Feb., 2002 M-1 Feb.,

More information

TPHIC Series Constant Pressure Inverter Control System

TPHIC Series Constant Pressure Inverter Control System TPI Series onstant Inverter ontrol System Power: 0. - P : Up to kg/cm² Flow: Up to L/min : " -" pplications partment buildings, houses, villa water supply, factories, water supply systems, drinking water

More information

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor DMP Industrial Pressure Transmitter for Low Pressure Stainless Steel Sensor accuracy according to IEC 60770: : 0.5 % FSO option: 0.5 / 0. % FSO Nominal pressure from 0... 00 mbar up to 0... 60 bar Output

More information

Suction fi lters. SF series. Flow rate up to 160 l/min. Suction fi lters

Suction fi lters. SF series. Flow rate up to 160 l/min. Suction fi lters Suction fi lters SF 00 series Flow rate up to 60 l/min Suction fi lters FILTER SIZING The correct filter sizing have to be based on the variable pressure drop depending by the application. For example,

More information

GRUNDFOS DATA BOOKLET MAGNA, UPE. Series 2000 circulator pumps

GRUNDFOS DATA BOOKLET MAGNA, UPE. Series 2000 circulator pumps GRUNDFOS DATA BOOKLET MAGNA, UPE Series circulator pumps Contents Product data MAGNA and UPE 3 Duty range 3 Characteristic features 3 Benefits 3 Applications 3 eating systems 3 Pumped liquids Type key

More information

AIR PREPARATION. ELECTRONICALLY CONTROLLED PRESSURE REGULATING VALVE (PROPORTIONAL PRESSURE REGULATING VALVE) SERIES control

AIR PREPARATION. ELECTRONICALLY CONTROLLED PRESSURE REGULATING VALVE (PROPORTIONAL PRESSURE REGULATING VALVE) SERIES control AIR PREPARATION ELECTRONICALLY CONTROLLED PRESSRE REGLATING ALE (PROPORTIONAL PRESSRE REGLATING ALE) SERIES control Description Abb. Port size Recommended Type Data Sheet No. flow (l/min)* airfit tecno

More information

Cipriani Harrison Valves Corp.

Cipriani Harrison Valves Corp. Butterfly Valve pplication Stainless steel hygienic butterfly valves are used in process piping systems for isolation and control. Butterfly valves operate either manually or automatically. Working Principle

More information

Surface-mounting thermostats Series ATH

Surface-mounting thermostats Series ATH JUMO GmbH & Co. KG Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 E-mail: mail@jumo.net Internet: www.jumo.net

More information

DS 300. Electronic Pressure Switch. with IO-Link interface. Stainless Steel Sensor. accuracy according to IEC 60770: 0.35 % FSO.

DS 300. Electronic Pressure Switch. with IO-Link interface. Stainless Steel Sensor. accuracy according to IEC 60770: 0.35 % FSO. DS 00 Electronic Pressure Switch with IO-Link interface Stainless Steel Sensor accuracy according to IEC 60770: 0.5 % FSO Nominal pressure from 0... 00 mbar up to 0... 600 bar Digital output signal IO-Link

More information

387 Low & Medium Pressure filters

387 Low & Medium Pressure filters Low & Medium Pressure fi lters LMD 000 & series Maximum pressure up to 6 bar Flow rate up to 90 l/min 87 Low & Medium Pressure filters FILTER SIZING The correct filter sizing have to be based on the variable

More information

CMA - B - C - D - CMR

CMA - B - C - D - CMR Cast iron self-priming electric pumps. APPLICATIONS Pressure boosting domestic plants Small-scale irrigation Moving non-aggressive liquids for civil and industrial use Washing plants Washing vehicles CMA-B-C-D

More information

Flow rates to 475 l/min

Flow rates to 475 l/min FMP Maximum pressure 0 bar Flow rates to 7 l/min Technical data PRSSUR FILTR Filter housing (Materials) ead: Cast iron (chemical heat treatment) ousing: Steel (chemical heat treatment) Bypass valve: Brass

More information

High Pressure fi lters

High Pressure fi lters High Pressure fi lters FMM 00 series Maximum pressure up to 0 bar Flow rate up to l/min FHA 0 series Maximum pressure up to 60 bar Flow rate up to 0 l/min 9 High Pressure fi lters FILTER SIZING The correct

More information

Differential Pressure Switch

Differential Pressure Switch Features Using piezoresistive pressure sensor, which is compensated and aged well; high accuracy, quick response; Amplifier circuit driving switch relay; relay value could be set freely between zero and

More information

/2 way valves (solenoid actuated diaphragm with forced lifting) 1/4... 2

/2 way valves (solenoid actuated diaphragm with forced lifting) 1/4... 2 / way valves (solenoid actuated diaphragm with forced lifting) /4... Damped operation Operation without differential Suitable for vacuum igh flow rate For systems with low or fluctuating Brass body Wide

More information

Capacitor Discharge called CD welding

Capacitor Discharge called CD welding TROUBLE SHOOTING OF STUD WELDING (EQUPMENT) We see several time, that the two main principles of Studwelding are mixed up therefor I will start to repeat short the welding methods. Capacitor Discharge

More information

6.0 EC-SERIES CUBERS EC200-EC300-EC400-EC500-EC606 AIR, WATER AND REMOTE

6.0 EC-SERIES CUBERS EC200-EC300-EC400-EC500-EC606 AIR, WATER AND REMOTE 6.0 EC-SERIES CUBERS EC200-EC300-EC400-EC500-EC606 AIR, WATER AND REMOTE Item EC EC EC EC EC EC Code Part Description Part Number GRP 200 300 400 406 500 606 AIR COOLED 5 Air Condenser 9141048-01 AC X

More information

Calio-Therm NC Type Series Booklet

Calio-Therm NC Type Series Booklet High-efficiency Drinking Water Pump Type Series Booklet Legal information/copyright Type Series Booklet All rights reserved. The contents provided herein must neither be distributed, copied, reproduced,

More information

High Pressure fi lters. FMP series. Maximum pressure up to 320 bar - Flow rate up to 475 l/min. High Pressure fi lters

High Pressure fi lters. FMP series. Maximum pressure up to 320 bar - Flow rate up to 475 l/min. High Pressure fi lters High Pressure fi lters FMP series Maximum pressure up to 0 bar Flow rate up to 7 l/min High Pressure fi lters FILTER SIZING The correct filter sizing have to be based on the variable pressure drop depending

More information

High Pressure fi lters. FHA 051 series. Maximum working pressure up to 56 MPa (560 bar) - Flow rate up to 140 l/min. High Pressure fi lters

High Pressure fi lters. FHA 051 series. Maximum working pressure up to 56 MPa (560 bar) - Flow rate up to 140 l/min. High Pressure fi lters High Pressure fi lters FHA 0 series Maximum working pressure up to 6 MPa (60 bar) Flow rate up to 0 l/min 99 High Pressure fi lters Introduction FILTER SIZG DEX CALCULATION CORRECTIVE FACTOR Page Introduction

More information

P U M P S. The quality standard for hydraulic efficiency and suction lift. PERIPHERAL PUMPS TEP/ TSP - SERIES 50Hz

P U M P S. The quality standard for hydraulic efficiency and suction lift. PERIPHERAL PUMPS TEP/ TSP - SERIES 50Hz P U M P S THE BENCHMARK FOR PERFORMANCE The quality standard for hydraulic efficiency and suction lift. PERIPHERAL PUMPS TEP/ TSP - SERIES 5Hz I N D E X TEP / TSP / TRP SERIES - PERIPHERAL PUMPS Page

More information

Industrial Pressure Transmitter

Industrial Pressure Transmitter ECT 87 Industrial Pressure Transmitter Swiss based Trafag is a leading international supplier of high quality sensors and monitoring instruments for measurement of and temperature. The economical transmitter

More information

Pressure Measurement. Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level 2/27

Pressure Measurement. Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level 2/27 Overview Siemens AG 011 Function s are for measuring the liquid levels in wells, tanks, channels and dams. Diaphragm p Sensor U const. U + (brown) I EM I -1 (blue) 0, U B s are submersible sensors for

More information

e-hm REPAIR PARTS REPAIR PARTS ReHM R3

e-hm REPAIR PARTS REPAIR PARTS ReHM R3 e-hm REPAIR PARTS REPAIR PARTS ReHM R3 TABLE OF CONTENTS Rating Plate..........................................................................................2 A li ati n ene t an n t......................................................................3

More information

331 Low & Medium Pressure filters

331 Low & Medium Pressure filters Low & Medium Pressure fi lters LMP 00-0 & 0- series Maximum pressure up to 60 bar - Flow rate up to 70 l/min Low & Medium Pressure filters FILTER SIZING The correct filter sizing have to be based on the

More information

GRUNDFOS DATA BOOKLET MAGNA, UPE. Series 2000 circulator pumps

GRUNDFOS DATA BOOKLET MAGNA, UPE. Series 2000 circulator pumps GRUNDFOS DATA BOOKLET Series circulator pumps Contents Product data MAGNA and UPE 3 Duty range 3 Characteristic features 3 Benefits 3 Applications 3 eating systems 3 Pumped liquids Type key 5 Performance

More information

SERIES. Maximum pressure 8 bar

SERIES. Maximum pressure 8 bar SERIES Maximum pressure 8 bar F l o w r a t e s t o 0 0 l / m i n OLD MPF 00 NEW MPF 00 8 75 80 5-6 5,5 5,5 Nr. holes Ø 8,5 55 55 Nr. slots Ø 8,5 Up to: G NPT SAE 6 Up to: G / SAE 0 DIFFERENCE BETWEEN...

More information

Flow rates to 485 l/min

Flow rates to 485 l/min FB Maximum pressure 0 bar Flow rates to 8 l/min Technical data Filter housing (Materials) ead: Cast iron (chemical heat treatment) ousing: Steel (chemical heat treatment) Bypass valve: Steel Check valve:

More information

Flow rates to 485 l/min

Flow rates to 485 l/min FB Maximum pressure 0 bar Flow rates to 8 l/min Technical data Filter housing (Materials) ead: Cast iron (chemical heat treatment) ousing: Steel (chemical heat treatment) Bypass valve: Steel Check valve:

More information

High Pressure fi lters. FHB series. Maximum pressure up to 320 bar - Flow rate up to 485 l/min. High Pressure fi lters

High Pressure fi lters. FHB series. Maximum pressure up to 320 bar - Flow rate up to 485 l/min. High Pressure fi lters High Pressure fi lters FHB series Maximum pressure up to 0 bar - Flow rate up to 8 l/min 8 High Pressure fi lters FILTER SIZING The correct filter sizing have to be based on the variable pressure drop

More information

The Ultimate Innovators

The Ultimate Innovators Product Over view america, inc. The Ultimate Innovators www.yamadapump.com Yamada Corporation S ince its beginning in 1905, Yamada has been at the forefront in developing the most complete line of air

More information

Grain Reserves, Volatility and the WTO

Grain Reserves, Volatility and the WTO Grain Reserves, Volatility and the WTO Sophia Murphy Institute for Agriculture and Trade Policy www.iatp.org Is v o la tility a b a d th in g? De pe n d s o n w h e re yo u s it (pro d uc e r, tra d e

More information

High Pressure fi lters. FHM series. Maximum pressure up to 320 bar - Flow rate up to 450 l/min. High Pressure fi lters

High Pressure fi lters. FHM series. Maximum pressure up to 320 bar - Flow rate up to 450 l/min. High Pressure fi lters High Pressure fi lters FHM series Maximum pressure up to 0 bar - Flow rate up to 0 l/min 67 High Pressure fi lters FILTER SIZING The correct filter sizing have to be based on the variable pressure drop

More information

LU N C H IN C LU D E D

LU N C H IN C LU D E D Week 1 M o n d a y J a n u a ry 7 - C o lo u rs o f th e R a in b o w W e w ill b e k ic k in g o ff th e h o lid a y s w ith a d a y fu ll o f c o lo u r! J o in u s fo r a ra n g e o f a rt, s p o rt

More information

Flow rates to 485 l/min

Flow rates to 485 l/min FB Maximum pressure 0 bar Flow rates to 8 l/min Technical data Filter housing (Materials) ead: Cast iron (chemical heat treatment) ousing: Steel (chemical heat treatment) Bypass valve: Steel Check valve:

More information

DS 200 DS 200 DRUCK & TEMPERATUR LEITENBERGER GMBH. Electronic Pressure Switch. Stainless Steel Sensor. Electronic Pressure Switch

DS 200 DS 200 DRUCK & TEMPERATUR LEITENBERGER GMBH. Electronic Pressure Switch. Stainless Steel Sensor. Electronic Pressure Switch DRUCK & TEMPERATUR LEITENBERGER GMBH DS 00 Electronic Pressure Switch Stainless Steel Sensor accuracy according to IEC 00: standard: 0. % FSO option: 0. % FSO Nominal pressure: from 0... 00 mbar up to

More information

Sensors for pressure control OsiSense XMLR

Sensors for pressure control OsiSense XMLR Sensors for pressure control LR Catalogue Simply easy! TM Contents Sensors for pressure control LR General presentation........................ pages 00/ and 00/ Presentation..........................................

More information

LMP 210. Style B. Style S. Maximum pressure 60 bar F l o w r a t e s t o l / m i n

LMP 210. Style B. Style S. Maximum pressure 60 bar F l o w r a t e s t o l / m i n LMP 0 Style S Style Maximum pressure 60 bar F l o w r a t e s t o 7 0 l / m i n 6 Technical data Filter housing (Materials) Head: luminium Housing: nodised luminium ypass valve: Nylon - Steel Pressure

More information

IGBT Designer s Manual

IGBT Designer s Manual IGBT Designer s Manual Data Sheets The IGBT devices listed in this Designer s Manual represent International Rectifier s IGBT line as of August, 994. The data presented in this manual supersedes all previous

More information

Industrial Pressure Transmitter

Industrial Pressure Transmitter ECT 87 Industrial Pressure Transmitter Swiss based Trafag is a leading international supplier of high quality sensors and monitoring instruments for measurement of and temperature. The economical transmitter

More information

VOLUMEC. Valve Position Indicator 5

VOLUMEC. Valve Position Indicator 5 VOLUMEC Valve Position Indicator 5 2 KRACHT CORP. 8600 S Wilkinson Way Unit A Perrysburg, OH 43551 USA P +1 419 874 1000 F +1 419 874 1006 flowmeters@krachtcorp.com www.krachtcorp.com VOLUMEC Valve Position

More information

Element description. Multipass test in compliance ISO Contaminant ISO MTD. A - Microfibre

Element description. Multipass test in compliance ISO Contaminant ISO MTD. A - Microfibre Style FZ Stainless Steel Pressure filter Technical data element Style In-Line filter: FZ 00-0 FZP 0 FZ 0 FZP 6 FZX 0 Manifold mounting: FZ 0 FZM 0 Max. working pressure: 700 bar Max. working pressure:

More information

Return fi lters. MPI series. Maximum working pressure up to 1 MPa (10 bar) - Flow rate up to 3000 l/min

Return fi lters. MPI series. Maximum working pressure up to 1 MPa (10 bar) - Flow rate up to 3000 l/min Return fi lters series Maximum working pressure up to MPa (0 bar) Flow rate up to 000 l/min 0 Return fi lters Introduction FILTER SIZING INDEX CALCULATION CORRECTIVE FACTOR Page Introduction Calculation

More information

INTERIM MANAGEMENT REPORT FIRST HALF OF 2018

INTERIM MANAGEMENT REPORT FIRST HALF OF 2018 INTERIM MANAGEMENT REPORT FIRST HALF OF 2018 F r e e t r a n s l a t ion f r o m t h e o r ig ina l in S p a n is h. I n t h e e v e n t o f d i s c r e p a n c y, t h e Sp a n i s h - la n g u a g e v

More information

THE ANSWER TO PROBLEMS OF: CORROSION, ABRASION, GRANULATED MATERIALS, POWDERS, SLUDGE, GAS ETC.

THE ANSWER TO PROBLEMS OF: CORROSION, ABRASION, GRANULATED MATERIALS, POWDERS, SLUDGE, GAS ETC. P PINC VLVE Mod. S pag. Mod. S pag. Mod. S pag. Mod. SD pag. Mod. S pag. Mod. S pag. 0 Mod. S pag. Mod. S pag. Mod. S pag. Mod. S0 pag. Mod. S pag. 0 Mod. S pag. Mod. S pag. Mod. S pag. Mod. S pag. TE

More information

REFUGEE AND FORCED MIGRATION STUDIES

REFUGEE AND FORCED MIGRATION STUDIES THE OXFORD HANDBOOK OF REFUGEE AND FORCED MIGRATION STUDIES Edited by ELENA FIDDIAN-QASMIYEH GIL LOESCHER KATY LONG NANDO SIGONA OXFORD UNIVERSITY PRESS C o n t e n t s List o f Abbreviations List o f

More information

gender mains treaming in Polis h practice

gender mains treaming in Polis h practice gender mains treaming in Polis h practice B E R L IN, 1 9-2 1 T H A P R IL, 2 O O 7 Gender mains treaming at national level Parliament 25 % of women in S ejm (Lower Chamber) 16 % of women in S enat (Upper

More information

359 Low & Medium Pressure filters. LMP series. Maximum pressure up to 30 bar - Flow rate up to 2400 l/min. Low & Medium Pressure fi lters

359 Low & Medium Pressure filters. LMP series. Maximum pressure up to 30 bar - Flow rate up to 2400 l/min. Low & Medium Pressure fi lters Low & Medium Pressure fi lters LMP 909 series Maximum pressure up to 0 bar Flow rate up to 00 l/min 9 Low & Medium Pressure filters FILTER SIZING The correct filter sizing have to be based on the variable

More information

LMP series Filter element according to DIN Maximum pressure up to 30 bar - Flow rate up to 2000 l/min

LMP series Filter element according to DIN Maximum pressure up to 30 bar - Flow rate up to 2000 l/min Low & Medium Pressure fi lters LMP 90090 series according to DIN 0 Maximum pressure up to 0 bar Flow rate up to 000 l/min Low & Medium Pressure filters FILTER SIZING The correct filter sizing have to be

More information

Maximum pressure 80 bar

Maximum pressure 80 bar Maximum pressure 80 bar F l o w r a t e s t o 0 0 l / m i n LMP 0 Maximum pressure 80 bar F l o w r a t e s t o 6 0 l / m i n Technical data LMP 0 Filter housing (Materials) Head: luminium Housing: ataphoresis

More information

E 094 E 103 E 143. Tank top mounting Connection up to G1 Nominal flow rate up to 135 l/min e

E 094 E 103 E 143. Tank top mounting Connection up to G1 Nominal flow rate up to 135 l/min e R e t u r n F i l t e rs E 094 E 103 E 143 Tank top mounting Connection up to G1 Nominal flow rate up to 135 l/min 20.30-5e D e s c r i p t i o n Application In the return line circuits of hydraulic systems.

More information

Stainless Steel Sanitary Products. 3A & BPE Industry Standard Designs Without Brand Name Price. More For Less

Stainless Steel Sanitary Products. 3A & BPE Industry Standard Designs Without Brand Name Price. More For Less Stainless Steel Sanitary Products 3A & BPE Industry Standard Designs Without Brand Name Price More For Less Material Inspection Certification EN 10204 3.1 Positive Material Identification ( PMI ) X-Ray

More information

The v alv e s with plug c onn e ctions in front are p erfera bly us e d on v alv e m o d ule s.

The v alv e s with plug c onn e ctions in front are p erfera bly us e d on v alv e m o d ule s. 3/2 and 5/2 way valves Flow rate: 130 l/min; M5 and Legris ø 4 port connection Advantages / Benefits Optimal system solutions due to high level of modularity Maintenance-free and no wear due to high level

More information

EKOLOGIE EN SYSTEMATIEK. T h is p a p e r n o t to be c i t e d w ith o u t p r i o r r e f e r e n c e to th e a u th o r. PRIMARY PRODUCTIVITY.

EKOLOGIE EN SYSTEMATIEK. T h is p a p e r n o t to be c i t e d w ith o u t p r i o r r e f e r e n c e to th e a u th o r. PRIMARY PRODUCTIVITY. EKOLOGIE EN SYSTEMATIEK Ç.I.P.S. MATHEMATICAL MODEL OF THE POLLUTION IN NORT H SEA. TECHNICAL REPORT 1971/O : B i o l. I T h is p a p e r n o t to be c i t e d w ith o u t p r i o r r e f e r e n c e to

More information

Surface-mounting Thermostats ATH Type Series

Surface-mounting Thermostats ATH Type Series Page 1/9 urface-mounting Thermostats ATH eries k enclosure protection IP 54 k tested to IN EN 14597 (replacing IN 3440) Brief description Thermostats control and monitor thermal processes. Instruments

More information

Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level

Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level Overview Function s are for measuring the liquid levels in wells, tanks, channels and dams. Sensor Diaphragm p U const. U +2 (brown) I EM I - (blue) 0, U B s are submersible sensors for hydrostatic level

More information

C o r p o r a t e l i f e i n A n c i e n t I n d i a e x p r e s s e d i t s e l f

C o r p o r a t e l i f e i n A n c i e n t I n d i a e x p r e s s e d i t s e l f C H A P T E R I G E N E S I S A N D GROWTH OF G U IL D S C o r p o r a t e l i f e i n A n c i e n t I n d i a e x p r e s s e d i t s e l f i n a v a r i e t y o f f o r m s - s o c i a l, r e l i g i

More information

Cartridge Valves Technical Information

Cartridge Valves Technical Information Quick reference CONTENTS CPF20... 8.2 CP600-5... 8. CP602-5... 8.4 20662 handle kit... 8.5 MP06... 8.6 MP2... 8.6 BC06... 8.9 BC0... 8.0 BC... 8. CP0-... 8. CP904-... 8.4 SC0... 8.5 SC... 8.6 DIN connectors...

More information

Vacuum Chambers. Type DK /DK /DK

Vacuum Chambers. Type DK /DK /DK Vacuum Chambers Type DK 020.010/DK 070.010/DK 050.010 Tel: (609) 924-3011 Fax (609) 924-3018 www.princetonscientific.com Email: info@princetonscientific.com Vacuum Chambers Application: Vacuum chambers

More information

Sample and Bleed Valves

Sample and Bleed Valves Pure-Flo Sample and Bleed Valves www.ittpureflo.com Application The Pure-Flo product line of Sample and Bleed Valves provides compact and economical means to extract process samples and bleed off excess

More information

ISEmax CAS40D. Technical Information

ISEmax CAS40D. Technical Information Technical Information ISEmax CAS40D Online measurement of nutrient parameters Ion-selective electrodes for the continuous measurement of ammonium, nitrate and other ions Application The ion-selective sensor

More information

compact ejector, Series ECS with release valve with silencer with non-return valve, With filter vacuum switch: electronic 1x PNP and 1x analog

compact ejector, Series ECS with release valve with silencer with non-return valve, With filter vacuum switch: electronic 1x PNP and 1x analog with release valve with silencer with non-return valve, With filter vacuum switch: electronic x PNP and x analog Ambient temperature min./max. +0 C / +0 C Medium temperature min./max. +0 C / + C Working

More information

Use precise language and domain-specific vocabulary to inform about or explain the topic. CCSS.ELA-LITERACY.WHST D

Use precise language and domain-specific vocabulary to inform about or explain the topic. CCSS.ELA-LITERACY.WHST D Lesson eight What are characteristics of chemical reactions? Science Constructing Explanations, Engaging in Argument and Obtaining, Evaluating, and Communicating Information ENGLISH LANGUAGE ARTS Reading

More information

MRH. Return Filters RETURN FILTER

MRH. Return Filters RETURN FILTER MRH Return ilters RETUR ILTER Return ilters MRH MRH MPa (0 bar) Port sizes: / / low rates:.00 l/min TECHICAL ATA Max. working pressure: MPa (0 bar) Max. test pressure: MPa ( bar) ursting pressure: 6 MPa

More information

IBV Series C Carbon Steel Inverted Bucket Vertical Steam Trap

IBV Series C Carbon Steel Inverted Bucket Vertical Steam Trap Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

Air Cooler Industry AC-LN 1-7 / ACA-LN 2-7 / ACAF-LN 2-7

Air Cooler Industry AC-LN 1-7 / ACA-LN 2-7 / ACAF-LN 2-7 ir ooler Industry -LN -7 / -LN -7 / F-LN -7 Symbol General The -LN -7 air cooler series can be used in all areas where either oil or water-glycol is to be cooled with air. The coolers with an axial fan

More information

IBV Series Z Alloy Steel Inverted Bucket Vertical Steam Trap

IBV Series Z Alloy Steel Inverted Bucket Vertical Steam Trap Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

Solenoid valve Types EVR 2 - EVR 40

Solenoid valve Types EVR 2 - EVR 40 Data sheet Solenoid valve s EVR 2 - EVR 40 EVR is a direct or servo operated solenoid valve for liquid, suction, and hot gas lines with HCFC and HFC refrigerants. EVR valves are supplied complete or as

More information

OH BOY! Story. N a r r a t iv e a n d o bj e c t s th ea t e r Fo r a l l a g e s, fr o m th e a ge of 9

OH BOY! Story. N a r r a t iv e a n d o bj e c t s th ea t e r Fo r a l l a g e s, fr o m th e a ge of 9 OH BOY! O h Boy!, was or igin a lly cr eat ed in F r en ch an d was a m a jor s u cc ess on t h e Fr en ch st a ge f or young au di enc es. It h a s b een s een by ap pr ox i ma t ely 175,000 sp ect at

More information

50/60 Hz. ecocirc XL and XLplus. high efficiency WET ROTOR circulators. ErP 2009/125/EC

50/60 Hz. ecocirc XL and XLplus. high efficiency WET ROTOR circulators. ErP 2009/125/EC / Hz ecocirc XL and XLplus high efficiency WET ROTOR circulators FOR COMMERCIAL HEATING AND COOLING applications ErP 9/1/EC Cod. 1971 Rev. C Ed.11/1 Lowara, ecocirc, Xylect are trademarks of Xylem Inc.

More information