Coflore Agitated Cell Reactor
|
|
- Poppy Joseph
- 5 years ago
- Views:
Transcription
1 Coflore Agitated Cell Reactor
2 Coflore ACR The Coflore ACR is a lab flow reactor developed by AM Technology for studying chemistry in flow and developing scalable continuous processes. Its flexible design enables it to handle: Fast exothermic processes of less than 30 seconds Slow mass transfer or kinetically limited processes lasting hours Common process mixtures involving solids, slurries and gasses Active mixing, combined with multiple cells, provides the key to scale up with Coflore. If it works in the lab, it will work on the plant. The Coflore ACR is the starting point for developing flow chemistry solutions at the plant scale.
3 Advantages Highly configurable Options include co and counter current process plates, different materials of construction and adjustable working volumes. Cleanable All wetted surfaces are accessible for cleaning. Wide scope of chemistry Works with residence times from seconds to hours. Mixtures containing slurries and gases can be processed. Simple to use Minimal set up required. Residence time is fixed by the pump feed rate not the size of the reactor tubing. Good mixing and plug flow is maintained by default. Wide pump selection Very low pressure drops for both process and heat transfer fluid, greatly expands your choice of pumps. A tool for lab chemistry Reactor contents can be observed through glass windows. Operates with low working volumes and simple controls.
4 Features Reactor cabinet The stainless steel enclosure isolates the control equipment and drive mechanism from the process fluids. The reactor enclosure has a hinged lid, drip tray and ventilation connection. ATEX rated cabinets are available for hazardous area use. Configurable Reactor Block The demountable reactor block has 10 reaction cells for excellent plug flow. Borosilicate windows give visibility into the reaction cells. It can be fully dismantled for reconfiguration or cleaning. Sample points, addition points and temperature measurement can be added to any of the 10 reaction cells. Controls Temperature measurement and agitation control are standard on all models. Advanced control units provide 10 point temperature monitoring, data logging and programmable I/O for controlling peripherals such as pumps and valves. Temperature control Heat transfer fluid passes through the back plate of the reactor block and is actively mixed for outstanding performance. Standard laboratory heater/chillers can be connected to the reactor cabinet.
5 Configuration Cabinet Simple Capable Easy to clean Heat Transfer Plate Process Plate Agitators Flexible Front plate
6 ACR Cabinet Standard ACR Control Advanced ACR Control The standard ACR control cabinet provides essential control features for operation. This includes a start/stop agitation button, a dial to select agitation frequency and a dial to select a temperature reading from up to 10 temperature probes. The advanced ACR control cabinet is packed with additional features. A 5.5 interactive touchscreen allows the user to do everything the standard machine can plus process monitoring, data logging and much more. Features Standard Advanced Variable agitation control Temperature measurement Removable reactor block Containment enclosure Air supply pressure regulator Process monitoring Control auxiliary equipment remotely Data logging Air supply pressure transmitter Programmable safety alarm
7 ACR Reactor Block The ACR reactor block consists of a: Front plate with process windows Process plate with agitators Rear heat transfer plate Process Plate A series of reaction cells provide a path for process material. Side entry ports allow for reaction monitoring, sampling and addition. Process plates are interchangeable with two designs. Agitators Free moving agitators can be placed in each reactor cell. Mixing is generated by the ACR shaking the reactor block side to side. Agitators are interchangeable with various designs. Front Plate Windows can provide visibility for observing the chemistry. Windows are interchangeable with entry ports for reaction monitoring, sampling and addition. Heat Transfer Plate Control reaction temperature by applying heating or cooling with the heat transfer plate. Coflore ACR. Simple. Cleanable. Flexible.
8 ACR Process Plate ACR-100 The standard process plate has a working volume from 30 to 100 ml. It is suitable for homogeneous and heterogeneous, multiphase mixtures. The ACR-100 process plate fits inside an ACR reactor block assembly which is mounted onto a Coflore ACR Control Cabinet. It has 10 reaction stages and features glass viewing windows, side and front entry ports to the reaction cells, single and multiport injection nozzles and multipoint temperature measurement. Dimensions Cell diameter: 25 mm Reactor volume: 100 ml No. of channels: 11 Channel size: 4 x 4 mm Cell depth: 20 mm ACX-100 The ACX-100 process plate is used for counter-current operations which includes counter current extraction and reactions. It can handle multiphase materials flowing in opposite directions. The ACX-100 process plate can replace the ACR-100 process plate and then be fitted into a Coflore ACR Control Cabinet. Continuous counter current extractors give higher extraction efficiency with lower solvent usage. Dimensions Cell diameter: 25 mm Reactor volume: 100 ml No. of channels: 20 Channel size: 4 x 4 mm Cell depth: 20 mm
9 ACR Agitators Cylindrical To meet the demands of a wide range of chemistry, all agitators developed at AM Technology are tried and tested, with each design evolving to meet real challenges faced in the lab. Choose from three standard designs: High Shear, Cylindrical and Catalyst Basket. Materials of construction include stainless steel, Hastelloy, tantalum and Ceramic. Cylindrical agitators are available in three sizes; 30%, 50% and 70%. These are selected according to the working volume required in the ACR. High Shear Catalyst Basket High Shear agitators are especially designed for processes that require intense shear mixing. Applications include gas / liquid, solid / liquid, liquid / liquid and gas / liquid / solids. Catalyst Basket agitators are designed specifically for solid catalysed reactions. Catalyst particle sizes of between 0.4 mm and 2 mm can be loaded into the enclosed basket.
10 Heat Transfer Plate The heat transfer plate provides many key advantages and features. These include: Outstanding performance - even at low flow rates of heat transfer fluid. Unique design allows low pressure heater/chiller circulators to be used. Adjust the heat transfer fluid flow rate for a desired temperature profile through the reactor. Run more chemistry neat, closer to the kinetic limit in confidence
11 Specifications Working volume: 30ml, 50ml, 70ml, 100ml Residence time: 10 seconds to >8 hours Mixing (process side): Active mixing Mixing (heat transfer side) : Active mixing Agitation speed: 2 9 Hz Number of mixed stages: 10 Reactor temperature: -40 o C to o C Pressure: 0 to 10 barg (145 psi) Materials: Stainless steel, Hastelloy, PTFE Production scale: Grams to kilograms Throughput: 0.1 ml/min to 300 ml/min Addition points: 10 side ports, one for each cell Containment: Stainless steel enclosure with extractor connection Temperature monitoring: Up to 10 points Data logging: Programmable process parameter recording Alarm function: Set high or low alarms
12 Scale-Up Flow Chemistry Coflore ACR Flexible Multiphase
LABOTRON EXTRACTION & SYNTHESIS 2450 MHz
LABOTRON EXTRACTION & SYNTHESIS 2450 MHz The LABOTRON TM series is the generic name for a ground breaking range of integrated reactor and microwave transmission systems especially designed to carry out
More informationTHE VERSATILE VSP2: A TOOL FOR ADIABATIC THERMAL ANALYSIS AND VENT SIZING APPLICATIONS
THE VERSATILE VSP2: A TOOL FOR ADIABATIC THERMAL ANALYSIS AND VENT SIZING APPLICATIONS Charles F. Askonas, Dr. James P. Burelbach, and Dr. Joseph C. Leung Fauske and Associates, Inc. 16W070 W. 83 rd Street
More informationCHEMICAL REACTION ENGINEERING LAB
CHEMICAL REACTION ENGINEERING LAB EQUIPMENTS 1.CHEMICAL REACTORS SERVICE UNIT The chemical reactors service unit consists of a moulded ABS plinth which is used as a mounting for the chemical reactor to
More informationIndustrial Applications of Microreactor Technology
Industrial Applications of Microreactor Technology Name / Lonza AG / xx Month 2010 Microreactors are at the heart of a dramatic shift in API production Microreactor (MR) technology enables continuous processes
More informationHigh-Performance Continuous Flow Chemistry Systems. Robust Accurate Flexible Safe
High-Performance Continuous Flow Chemistry Systems Robust Accurate Flexible Safe Flow chemistry systems from Uniqsis Uniqsis designs and manufactures of a range of bench top continuous flow chemistry systems
More informationCHEMICAL REACTORS TEACHING EQUIPMENT CEXC
CE SERIES: BASIC PROCESS PRINCIPLES CHEMICAL REACTORS TEACHING EQUIPMENT CEXC NOW COMPUTER CONTROLLED AS STANDARD 3 NEW REACTORS AVAILABLE CEXC service unit shown fitted with CEB-MkIII transparent batch
More informationION CHROMATOGRAPHY SYSTEM S 150
ION CHROMATOGRAPHY SYSTEM S 150 WATER ANALYSIS ENVIRONMENTAL ANALYSIS ANION & CATION ANALYSIS ION CHROMATOGRAPHY IIon Chromatography is an analytical separation technique based on ionic interactions. Dissolved
More informationFlowCAT a versatile continuous flow reactor system focusing on reactions under elevated pressure and/or involving heterogeneous catalysis.
1 FlowCAT - a versatile continuous flow reactor system FlowCAT a versatile continuous flow reactor system focusing on reactions under elevated pressure and/or involving heterogeneous catalysis. By Dr Jasbir
More informationADI 2040 Process Analyzer
ADI 2040 Process Analyzer Multi-purpose wet chemical analysis Multi-purpose Wet Chemical Analysis ADI 2040 The Metrohm Applikon ADI 2040 Process Analyzer is a multipurpose wet chemical analyzer, that has
More informationLecture (9) Reactor Sizing. Figure (1). Information needed to predict what a reactor can do.
Lecture (9) Reactor Sizing 1.Introduction Chemical kinetics is the study of chemical reaction rates and reaction mechanisms. The study of chemical reaction engineering (CRE) combines the study of chemical
More informationThe integration of NeSSI with Continuous Flow Reactors and PAT for Process Optimization
The integration of NeSSI with Continuous Flow Reactors and PAT for Process Optimization Michael F. Roberto, Thomas I. Dearing and Brian J. Marquardt U.S. Food and Drug Administration 1 FDA Sponsored CFR
More informationSupporting Information. Flow Grignard and Lithiation: Screening Tools and Development of Continuous Processes
for: Flow Grignard and Lithiation: Screening Tools and Development of Continuous Processes for a Benzyl Alcohol Starting Material Michael E. Kopach, *, Kevin P. Cole, Patrick M. Pollock, Martin D. Johnson,
More informationContinuous Flow Reactions. From idea to production size scale up in 3 steps
Continuous Flow Reactions From idea to production size scale up in 3 steps PIN NL Spring Session 13 04 2017 13 4 2017 PIN NL Spring Session 1 Topics Introduction Flowlink Continuous Flow Reactions What
More informationChemistry Instrumental Analysis Lecture 31. Chem 4631
Chemistry 4631 Instrumental Analysis Lecture 31 High Performance Liquid Chromatography (HPLC) High Performance Liquid Chromatography (HPLC) High Performance Liquid Chromatography (HPLC) Solvent Delivery
More informationon TM 2012 KinetiChem, Inc. Irvine, CA Jeffrey C. Raber, Ph.D.
Synthetr Synthetron TM on TM Flow Reactor Technology 2012 KinetiChem, Inc. Irvine, CA Jeffrey C. Raber, Ph.D. Flow chemistry offers significant advantages Current flow reactor technology does not meet
More informationUtilizing Adaptive Focused Acoustics (AFA) Technology to Control Nucleation and Crystal Distribution During API Crystallization
COVARIS PROPRIETARY C O V A R I S P R O C E S S T E C H N O L O G I E S Carl Beckett cbeckett@covarisinc.com Utilizing Adaptive Focused Acoustics (AFA) Technology to Control Nucleation and Crystal Distribution
More informationBOXA-II ON-STREAM X-RAY FLUORESCENCE ANALYZER. Technical Description Version 2 BGRIMM AUTOMATION
BOXA-II ON-STREAM X-RAY FLUORESCENCE ANALYZER Technical Description Version 2 BGRIMM AUTOMATION, South 4th Ring Road West, Beijing, China TEL: +86(10)59069762 Fax: +86(10)68360101 Contents BGRIMM AUTOMATION
More informationTemperature control for Varian Cary line of UV/Vis Spectrophotometers and the Eclipse Fluorometer
Temperature control for Varian Cary line of UV/Vis Spectrophotometers and the Eclipse Fluorometer Temperature Control without Compromise: rapid changes, precise temperatures, powerful complex functionality.
More informationStructure of the chemical industry
CEE-Lectures on Industrial Chemistry Lecture 1. Crystallization as an example of an industrial process (ex. of Ind. Inorg. Chemistry) Fundamentals (solubility (thermodynamics), kinetics, principle) Process
More informationLonza Factory of Tomorrow for Flow Processes and MicroReactors
Pharma&Biotech Lonza Factory of Tomorrow for Flow Processes and MicroReactors Practical Continuous Flow Technology, Munich, Germany Dominique Roberge / Lonza Ltd, 3930 Visp / 5 June 2013 Lonza Re-design
More informationExperiment (3): Impact of jet
Experiment (3): Impact of jet Introduction: Impact of jets apparatus enables experiments to be carried out on the reaction force produced on vanes when a jet of water impacts on to the vane. The study
More informationWhat is Flow Reactor. High efficiency reaction using Microreactor. Reaction example. Flow Reactor. What s Flow Reactor.
What s --------------------------- 176 KeyChem Series------------------------------- 177 Micro System ------------------- 177 Hydrogenation System------- 177 Flow Photoreactor System---------------------
More informationFlowSyn The Continuous Flow Reactor from Uniqsis Designed by chemists for chemists
FlowSyn The Continuous Flow Reactor from Uniqsis Designed by chemists for chemists FlowSyn range overview MeO At the forefront of flow reactor design, FlowSyn is the platform of choice within major pharmaceutical
More informationMeasurement of Conductivity of Liquids
Name: Lab Section: Date: ME4751, Energy Systems Laboratory Measurement of Conductivity of Liquids Objective: The objective of this experiment is to measure the conductivity of fluid (liquid or gas) and
More informationUNIVERSITY OF MINNESOTA DULUTH DEPARTMENT OF CHEMICAL ENGINEERING ChE CONTINUOUS BINARY DISTILLATION
UNIVERSITY OF MINNESOTA DULUTH DEPARTMENT OF CHEMICAL ENGINEERING ChE 3211-4211 CONTINUOUS BINARY DISTILLATION OBJECTIVE The objective of this experiment is to determine the overall column efficiency for
More informationHigh Pressure Chemistry. Hydrogenation & Catalysis Tools.
High Pressure Chemistry Hydrogenation & Catalysis Tools www.helgroup.com HYDROGENATION AND CATALYSIS Product Selection Guide HEL Group s top quality high pressure reactors and systems offer innovative,
More informationED 701 General Industry Pressure Transmitter
ED 701 General Industry Pressure Transmitter Standard industrial process connections Complete range of electrical connections 4... 20 ma and Voltage outputs Accuracy: 0.1%, 0.2% and 0.4% FS Quick response
More informationC80. Calvet Calorimeter From ambient to 300 C. A trademark of KEP Technologies group
C80 Calvet Calorimeter From ambient to 300 C A trademark of KEP Technologies group C80 SENSOR The C80 Calorimeter is one of the most powerful, yet flexible calorimeters available. The high precision Calvet
More informationLABORATORY LINE. REACTRON RT 1 and RT 2. Reaction and mixing processes at a laboratory level, modular design laboratory reactors
LABORATORY LINE REACTRON RT 1 and RT 2 Reaction and mixing processes at a laboratory level, modular design laboratory reactors Efficient and economic. RT 1 and RT 2 REACTRON laboratory systems consist
More informationTechnical Resource Package 1
Technical Resource Package 1 Green Chemistry Impacts in Batch Chemical Processing UNIDO IAMC Toolkit Images may not be copied, transmitted or manipulated 1/5 The following list provides an overview of
More informationcostech instruments ECS 4010 Elemental Combustion System CHNS-O
instruments ECS 4010 Elemental Combustion System CHNS-O costech Costech Analytical Tecnologies Inc. 26074 Avenue Hall, Suite 14 Valencia, CA 91355 - USA Phone: (661) 297-2395 Fax: (661) 297-5492 e-mail:
More informationHigh Performance Liquid Chromatography
High Performance Liquid Chromatography What is HPLC? It is a separation technique that involves: Injection of small volume of liquid sample Into a tube packed with a tiny particles (stationary phase).
More informationThermal Soil Desorber Instructions September 2006
The SRI Thermal Soil Desorber is mounted in the valve oven section of the 8610C GC chassis. The 8610C GC shown in the photo is sitting next to the H2-40XR Hydrogen generator on the benchtop. With both
More informationPressure & temperature sampling options for Hiden gas analysis systems
QIC Series Gas Analysers Pressure & temperature sampling options for Hiden gas analysis systems Gas & Vapour Inlets STANDARD QIC QUARTZ INLET CAPILLARY: Sample pressure range 2 bar to 100 mbar Operates
More informationLC walk-up system using the Agilent 1200 Series LC Method Development Solution and Agilent Easy Access software. Application Note
LC walk-up system using the Agilent 12 Series LC Method Development Solution and Agilent Easy Access software Test of reaction kinetics, column scouting, and impurity checks with one LC system and up to
More informationFlowSyn The Continuous Flow Reactor from Uniqsis Designed by chemists for chemists
Designed by chemists for chemists Cl Reflux MeO HO FlowSyn from Uniqsis The FlowSyn continuous flow reactor has been designed by chemists, for chemists. Whether you are new to flow chemistry or an advanced
More informationData requirements for reactor selection. Professor John H Atherton
Data requirements for reactor selection Professor John H Atherton What is my best option for manufacturing scale? Microreactor Mesoscale tubular reactor Tubular reactor OBR (oscillatory baffled flow reactor)
More informationCHEMICAL ENGINEERING LABORATORY CHEG 4137W/4139W. Reaction Kinetics Saponification of Isopropyl Acetate with Sodium Hydroxide
CHEMICAL ENGINEERING LABORATORY CHEG 4137W/4139W Reaction Kinetics Saponification of Isopropyl Acetate with Sodium Hydroxide Objective: The purpose of this experiment is to examine and determine the reaction
More informationMetz Syn 10 Reaction Station
Metz Syn 10 Reaction Station For parallel chemistry, process development and reaction optimisation Simultaneously carry out 10 reactions, but each with a different temperature, from -30 C to +150 C...
More informationNR ROTARY RING TABLE: FLEXIBLE IN EVERY RESPECT
NR FREELY PROGRAMMABLE ROTARY TABLES NR ROTARY RING TABLE All NR rings allow customer-specific drive motors to be connected NR ROTARY RING TABLE: FLEXIBLE IN EVERY RESPECT WHEN IT S GOT TO BE EXACT We
More informationFluid Cooling Industrial PF Series
Fluid Cooling Industrial PF Series 0916 STAINLESS STEEL PLATES CARBON STEEL FRAME Performance Notes Carry bar Gasketed plate style heat exchanger Tie rods Oil to water applications High performance Pressure
More informationPRODUCTION OF URANOUS NITRATE WITH HYDRAZINE NITRATE AS REDUCING AGENT IN PRESENCE OF ADAMS CATALYST FOR URANIUM RECONVERSION PURPOSES
PRODUCTION OF URANOUS NITRATE WITH HYDRAZINE NITRATE AS REDUCING AGENT IN PRESENCE OF ADAMS CATALYST FOR URANIUM RECONVERSION PURPOSES Abstract: K.S. Rao, K Kumaraguru & P.M. Gandhi. Fuel Reprocessing
More informationDMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm
DMP P Industrial Pressure Transmitter Process Connections With Flush Welded Stainless Steel accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 % FSO Nominal pressure from 0... 00 mbar up
More informationPressure transmitters for industrial applications MBS 32 and MBS 33
Data sheet Pressure transmitters for industrial applications MBS 32 and MBS 33 The standard pressure transmitters MBS 32 and MBS 33 are designed for use in almost all industrial applications, and offer
More informationEsterification in a PFR with Aspen Plus V8.0
Esterification in a PFR with Aspen Plus V8.0 1. Lesson Objectives Use Aspen Plus to determine whether a given reaction is technically feasible using a plug flow reactor. 2. Prerequisites Aspen Plus V8.0
More informationThe 505F Series 3/4/5-Way Ball Valve. Standard Features and Benefits. Operating Conditions. Specifications. Options
The 505F Series //5-Way Ball Valve The 505F is a true multi-way ball valve with balanced fourseat construction. This full port valve is available in a variety of flow plans which can replace multiple two-way
More informationKjeltec 2300 Analyzer Unit
Kjeltec 2300 Analyzer Unit Automatic distillation and approved colorimetric titration for analysis of Kjeldahl nitrogen/protein, ammonium- nitrogen, TKN, Direct distillation (DD), volatile acids/ bases
More informationhydrideicp Hydride Generation System
HG-MP2-4-A hydrideicp Generation System hydrideicp Hydride Generation System User Manual MP 2 hydrideicp Generation System Elemental Scientific Phone: 1.402.991.7800 Email: esi@icpms.com 1500 North 24th
More informationAutomatic titrators, TitroMatic
112 TitroMatic These are the fourth generation of CRISON titrators. CRISON has over 25 years experience in this field and knows that, for certain applications, the performance and cost of large titrator
More informationPAA-ANALYZERS PRINCIPLE OF OPERATION
PAA-ANALYZERS PRINCIPLE OF OPERATION The PAA process analyzer comprises a control unit and an analyzing section which includes the reaction chamber and measuring cell, reagent pumps and associated valves
More informationHPAPI Process, Scalability & Robustness
HPAPI Process, Scalability & Robustness Jason Hamm, Ph.D. Director, API Pilot Plants Bristol-Myers Squibb July 14, 2015 1 Agenda 1. Considerations for highly potent compounds 2. Addressing the risk for
More informationJumbo Cross Beam Ionizer
Jumbo Cross Beam Ionizer Version 1.0 September 30, 2008 Page 1 of 19 Table of Contents Cross Beam Ionizer... 1 Table of Contents... 2 1.0 Packing List... 3 1.1 Packing List for Cross Beam Ionizer... 3
More informationTE 75R RESEARCH RUBBER FRICTION TEST MACHINE
TE 75R RESEARCH RUBBER FRICTION TEST MACHINE Background: The Research Rubber Friction Test Machine offers the ability to investigate fully the frictional behaviour of rubbery materials both in dry and
More informationnovaa 800 D Atomic Absorption Spectrometer
Technical Data Atomic Absorption Spectrometer Cpt : +27 (0) 21 905 0476 Jhb : +27 (0) 11 794 Dbn : +27 (0) 31 266 2454 1/7 General The is a compact atomic absorption spectrometer with deuterium background
More informationResearch and Development on European Cleaning Solutions for Radioactive Applications. Clean air solutions
Research and Development on European Cleaning Solutions for Radioactive Applications Dipl. Ing. Axel Mahler, R&D Director Europe, Camfil AB, Sweden 19.03.2014 Your speaker: Axel Mahler, R&D Director Europe
More informationHomogenisation with Perfection
Homogenisation with Perfection Definition Homogenisation is the thorough mixing of two components of one system that are immiscible by their nature. Common application in microbiology is resuspending of
More informationcobas 8000 modular analyzer series Intelligent LabPower
cobas 8000 modular analyzer series Introducing the cobas 8000 modular analyzer series Because demanding jobs require intelligent and powerful solutions The cobas 8000 modular analyzer series is the latest
More information(Refer Slide Time: 00:10)
Chemical Reaction Engineering 1 (Homogeneous Reactors) Professor R. Krishnaiah Department of Chemical Engineering Indian Institute of Technology Madras Lecture No 10 Design of Batch Reactors Part 1 (Refer
More informationName of Course: B.Tech. (Chemical Technology/Leather Technology)
Name of : B.Tech. (Chemical Technology/Leather Technology) Harcourt Butler Technological Institute, Kanpur Study and [Effective from the Session 201-1] B. Tech. (Chemical Technology/Leather Technology)
More informationPART 2 Dr. Stephen Glover
Queens University Belfast Valorisation of Lignocellulosic Waste and the Potential of Supercritical Water and Wet Air Oxidation PART 2 Dr. Stephen Glover Workshop - Technology Foresight Conference, Cologne
More informationSafeN130 Movable Apparatus for Radioactive Noble Gases Removing
SafeN130 Movable Apparatus for Radioactive Noble Gases Removing Introduction The movable apparatus for removing radioactive noble gases which is developed from DS SCIENCE INC (Model SafeN130), is a prevention
More informationHumidity Calibration Solutions
Humidity Calibration Solutions www.michell.com Humidity Calibration Solutions The Importance of Regular Calibration The reliable operation of a hygrometer and indeed any measuring instrument, can only
More informationTHE USE OF DEWAR CALORIMETRY IN THE ASSESSMENT OF CHEMICAL REACTION HAZARDS
THE USE OF DEWAR CALORIMETRY IN THE ASSESSMENT OF CHEMICAL REACTION HAZARDS R.L. ROGERS* Dewar Calorimetry is one of the simplest and most useful techniques used in the assessment of chemical reaction
More informationClausing Industrial, Inc. Variable Speed 20" Single and Multi-spindle, Belt Drive Industrial Drill Presses
www.clausing-industrial.com Variable Speed 20" Single and Multi-spindle, Belt Drive Industrial Drill Presses Clausing Industrial, Inc. Two Speed Variable Speeds 150-2000rpm Variable Speeds 200-1300rpm
More informationElectrolysis System CHLORINSITU V (PLUS)
Output of 100 3.500 g/h of ultra-pure active chlorine (hypochlorous acid) Electrolysis systems of the type CHLORINSITU V generate ultrapure active chlorine using the unique vacuum method with the membrane
More informationGreen Engineering using Commercial Flow Reaction & Process Intensification Platforms. Vijay Kirpalani. CEO Pi Process Intensification Mumbai
Green Engineering using Commercial Flow Reaction & Process Intensification Platforms Vijay Kirpalani CEO Pi Process Intensification Mumbai 08-12-2013 Copyright Pi-Process Intensification Experts LLP 1
More informationProduct Description and Specification
Product Description and Specification Catalog No 7 Synthra [ 11 C]Choline Description Synthra [ 11 C]Choline is a completely automated synthesis system for routine production of [ 11 C]choline. Using in-target
More information98 Series Backpressure Regulators and Relief Valves
9 Series Backpressure Regulators and Relief Valves Bulletin.:9 November 09 W TYPE 9H W TYPE 9LD Figure. Typical 9 Relief Valves Introduction W TYPE 9HD The 9 Series (Figure ) is used for backpressure or
More informationFVBSS fixed volume bottle
N FVBSS fixed volume bottle Sampling System The SENSOR Fixed Volume Bottle Sampling System (FVBSS) provides a repeatable fixed volume of sample during each sampling process without stopping flow of the
More informationUniversity of Minnesota Nano Center Standard Operating Procedure
University of Minnesota Nano Center Standard Operating Procedure Equipment Name: Zeta Potential Analyzer Model: Stabino Location: PAN 185 Badger Name: Not on Badger Revision Number: 0-Inital release Revisionist:
More informationVapourtec UV-150 Photochemical Reactor. Application notes 37-39, 41-44, 47, 48
Vapourtec UV-150 Photochemical Reactor Application notes 37-39, 41-44, 47, 48 Bringing photochemistry to the bench - Photochemistry has a number of important applications in nature and industry. - Traditional
More informationITER DIAGNOSTIC PORT PLUG DESIGN. N H Balshaw, Y Krivchenkov, G Phillips, S Davis, R Pampin-Garcia
N H Balshaw, Y Krivchenkov, G Phillips, S Davis, R Pampin-Garcia UKAEA, Culham Science Centre, Abingdon, Oxon,OX14 3DB, UK, nick.balshaw@jet.uk Many of the ITER diagnostic systems will be mounted in the
More informationSECTION 1 - WHAT IS A BTU METER? BTU's = Flow x ΔT Any ISTEC BTU Meter System consists of the following main components:
SECTION 1 - WHAT IS A BTU METER? ISTEC BTU Meters measure energy usage by multiplying flow rate and temperature difference. As the water (or other liquid) passes through these lines, the multi-wing turbine
More informationDGCU165-5B 36 W. Five-Burner Cooktop
Standard Features & Accessories All models include Dimensioned fit the majority of similarly sized cookp cuuts Sealed burners with brass flame ports and porcelain/cast iron burner caps Burners mounted
More informationAdvancer Kilobatch. kilogram scale-up of all microwave chemistry
Advancer Kilobatch kilogram scale-up of all microwave chemistry Background MW reactions are become more common place in Discovery / Med Chem MW reactions can be higher yield / higher purity MW reactions
More informationReferences. Continuous Manufacturing Process Development Plant Realizations. Microinnova Engineering GmbH. Europapark Allerheiligen bei Wildon
References Continuous Manufacturing Process Development Plant Realizations Microinnova Engineering GmbH Europapark 1 8412 Allerheiligen bei Wildon T +43 (0) 3182 62626-0 office@microinnova.com www.microinnova.com
More informationField IT 50T Series Transmitters
Data Sheet SS/G/A_ Field IT 0T Series Transmitters gauge/absolute pressure transmitter Ranges: -00 to 0000kPa - to 00bar -. to 6000psi Base accuracy : 0.% (BFSL) Chemical Vapour Deposition (CVD) technology
More informationStates of Matter: Solid, Liquid, and Gas
Movie Special Effects Activity 2 States of Matter: Solid, Liquid, and Gas GOALS In this activity you will: Create an animation to illustrate the behavior of particles in different phases of matter, and
More informationSurPASS. Electrokinetic Analyzer for Solid Samples. ::: Innovation in Materials Science
SurPASS Electrokinetic Analyzer for Solid Samples ::: Innovation in Materials Science SurPASS For Solid Surface Analysis The SurPASS electrokinetic analyzer helps material scientists to improve surface
More informationMaximizing Triple Quadrupole Mass Spectrometry Productivity with the Agilent StreamSelect LC/MS System
Maximizing Triple Quadrupole Mass Spectrometry Productivity with the Agilent StreamSelect LC/MS System Application Note Authors Kevin McCann, Sameer Nene, Doug McIntyre, Edmond Neo, Dennis Nagtalon, and
More informationPanel Mount, Single Phase 120 and 240 Volt Fixed Shaft (click blue text for more details)
Staco Energy Products Co. has been a leading manufacturer of variable transformers for over 60 years, building standard as well as custom-designed products for industrial, commercial and military applications.
More informationRight. First Time in Fine-Chemical Process Scale-up. Lum(Bert)us A. Hulshof. Avoiding scale-up problems: the key to rapid success
Right First Time in Fine-Chemical Process Scale-up Avoiding scale-up problems: the key to rapid success Lum(Bert)us A. Hulshof Eindhoven University of Technology Eindhoven, The Netherlands V Preface About
More informationXBC300 Gen2. Fully-automated debonder and Cleaner
XBC300 Gen2 Fully-automated debonder and Cleaner XBC300 Gen2 FULLY AUTOMATED DEBONDER AND CLEANER The SUSS XBC300 Gen2 debonder and cleaner platform is designed for process development as well as high
More informationSOPHAS - Speeding up the process of discovery and optimisation
SOPHAS Automated System For Any Synthesis Application SOPHAS - Speeding up the process of discovery and optimisation The SOPHAS system is an automatic system for synthesis and sample preparation that comprises
More informationInnovation in. Motionless Mixers
Innovation in Motionless Mixers Ross Motionless Mixers PIONEERING TECHNOLOGY. INCOMPARABLE QUALITY. WORLDWIDE LEADERSHIP. Serving all the process industries in virtually every industrialized country around
More informationOperating Instructions for Digital Manometer. Model: MAN-SD
Operating Instructions for Digital Manometer Model: MAN-SD 1. Contents 1. Contents...2 2. Note...3 3. Instrument Inspection...3 4. Regulation Use...4 5. Operating Principle...4 6. Mechanical Connection...5
More informationDevelopment of an organometallic flow chemistry. reaction at pilot plant scale for the manufacture of
Supporting Information Development of an organometallic flow chemistry reaction at pilot plant scale for the manufacture of verubecestat David A. Thaisrivongs*, John R. Naber*, Nicholas J. Rogus, and Glenn
More informationApplied Fluid Mechanics
Applied Fluid Mechanics 1. The Nature of Fluid and the Study of Fluid Mechanics 2. Viscosity of Fluid 3. Pressure Measurement 4. Forces Due to Static Fluid 5. Buoyancy and Stability 6. Flow of Fluid and
More informationThe solution for all of your
The solution for all of your nanoparticle sizing and zeta potential needs. DelsaNano Series Blood Banking Capillary Electrophoresis Cell Analysis Centrifugation Genomics Lab Automation Lab Tools Particle
More informationcalorimeter heat flow calorimetry, power compensation calorimetry
calorimeter heat flow calorimetry, power compensation calorimetry Atlas simply does it all What is the Atlas Reaction Calorimeter? The Atlas Reaction Calorimeter accurately measures the power and enthalpy
More informationMercury Stack Monitor SM-4
Member of the envea Group Mercury Stack Monitor SM-4 Automatic continuous emission monitor (CEM) for mercury Continuous operation Sample dilution directly at stack - works with virtually any sample matrix
More informationApplied Fluid Mechanics
Applied Fluid Mechanics 1. The Nature of Fluid and the Study of Fluid Mechanics 2. Viscosity of Fluid 3. Pressure Measurement 4. Forces Due to Static Fluid 5. Buoyancy and Stability 6. Flow of Fluid and
More informationTECHNICAL MANUAL 820 LX / 910 LX / 1300 LX
TECHNICAL MANUAL 820 LX / 910 LX / 1300 LX LANCER reserves the right to modify, constantly its documentation for its improvement. The values of adjustments indicated in the displays of this manual are
More informationMicroscopy Cryostat System
OF AMERICA, INC. Microscopy Cryostat System RC102-CFM Microscopy Cryostat offers fast cooldown, high efficiency, lowest thermal drift, excellent temperature stability and ultra low vibration Optical cryostat
More informationNATIONAL CERTIFICATE (VOCATIONAL) APPLIED ENGINEERING TECHNOLOGY NQF LEVEL 4 NOVEMBER 2009
NATIONAL CERTIFICATE (VOCATIONAL) APPLIED ENGINEERING TECHNOLOGY NQF LEVEL 4 NOVEMBER 2009 (6021024) 30 October (Y-Paper) 13:00 16:00 A non-programmable scientific calculator may be used. This question
More informationResidual Chlorine Monitor
Data Sheet SS/AW00 Issue Residual Chlorine Monitor AW00 Total and Free Residual Chlorine Measurement add potassium iodide to reagent to convert free chlorine measurement to total chlorine Reagentless Operation
More informationdata sheet DONATELLO FAST General characteristics Rev. First emission - 01/07/ PRO02 code
DONATELLO FAST Automatic floor closed cycle tissue processor for histological specimens Automatic tissue processor for histological specimens DONATELLO FAST code PRO0 RI General characteristics DONATELLO
More informationNew Synthetic Technologies in Medicinal Chemistry
New Synthetic Technologies in Medicinal Chemistry Edited by Elizabeth Farrant Worldwide Medicinal Chemistry, Pfizer Ltd., Sandwich, Kent, UK Chapter 1 Chapter 2 Introduction Elizabeth Farrant 1.1 Introduction
More informationFukushima Daiichi Nuclear Power Station Unit 2 Primary Containment Vessel Internal Investigation
Fukushima Daiichi Nuclear Power Station Unit 2 Primary Containment Vessel Internal Investigation April 26, 2018 Tokyo Electric Power Company Holdings, Inc. 1. Primary containment vessel internal investigation
More informationAUTOMATED FORMULATION SYSTEMS
AUTOMATED FORMULATION SYSTEMS AUTOMATED FORMULATION ROBOT (GEOFF) SAMPLE TYPE GEOFF can handle ingredients with a wide viscosity range and has the capability to dispense slurries that require heating and