Cat. No. 140M-F M-D8E-B

Size: px
Start display at page:

Download "Cat. No. 140M-F M-D8E-B"

Transcription

1 Bulletin 0M Motor Protection Circuit Breakers Product Selection Motor Protection Circuit Breakers Short Circuit Protection Standard Magnetic Trip ( x I e ) Motor Overload Protection Trip Class Rated Operational Current (I e ) [A] Cat. No. 0M-C Motor Current Adjustment Range [A] Magnetic Trip Current [A] Cat. No. 0M-D Cat. No. 0-CMN Max. Short Circuit Current [ka] Max. -phase Hp Ratings Max. kw, -Phase AC- 00V (I cu ) 0V (group motor) 00V 0V 0V V 0V 00/V 00V 0V C-Frame Cat. No M-CE-A M-CE-A M-CE-A M-CE-A M-CE-B M-CE-B M-CE-B M-CE-B M-CE-B M-CE-C M-CE-C M-CE-C M-CE-C M-CE-C M-CE-C D-Frame M-DE-B M-DE-B M-DE-B M-DE-C M-DE-C M-DE-C M-DE-C M-DE-C M-DE-C F-Frame M-FE-C M-FE-C M-FE-C M-FE-C M-FE-C M-FE-C CMN-Frame Cat. No. 0M-F CMN CMN CMN CMN-000 Horsepower/kW ratings shown in the table above are for reference. The final selection of the MPCB depends on the actual motor full load current. - Publication A-CA00A-EN-P

2 Bulletin 0M Motor Protection Circuit Breakers Product Selection Motor Protection Circuit Breakers Short Circuit Protection Standard Magnetic Trip (Fixed at... x I e ) Overload Protection Trip Class...0 (Adjustable) Rated Operational Current (I e ) [A] Cat. No. 0M-I Cat. No. 0M-J Cat. No. 0M-L Motor Current Adjustment Range [A] Magnetic Trip Current [A] Ultimate Interrupting Current [ka] (I cm ) -phase Hp Ratings Max. kw, -Phase AC- 00V 0V 00V 0V 0V V 0V 00/V 00V 0V I-Frame Cat. No M-IE-C M-IE-D M-IE-D M-IE-D0 J-Frame M-JE-C M-JE-D M-JE-D M-JE-D M-JE-C M-JE-D M-JE-D M-JE-D L-Frame M-LE-D M-LE-D M-LE-D M-LE-D M-LE-D M-LE-D Horsepower/kW ratings shown in the table above are for reference. The final selection of the MPCB depends on the actual motor full load current. For IEC approvals and CE marking, add an "E" to the end of the Cat. No. Example: 0M-E-C0E. Overload Protection adjustable Trip Class,,, or 0. Overload Protection fixed Trip Class. Publication A-CA00A-EN-P -

3 Bulletin 0M Motor Protection Circuit Breakers Product Selection High Inrush Motor Protection Circuit Breakers Short Circuit Protection High Magnetic Trip (Fixed at x I e ) Motor Overload Protection Trip Class Rated Operational Current (I e ) [A] Motor Current Adjustment Range [A] Cat. No. 0M-C Magnetic Trip Current [A] Max. Short Circuit Current [ka] Max. -phase Hp Ratings Max kw, -Phase AC- 00V (I cu ) Cat. No. 0M-D 0V (group motor) 00V 0V 0V V 0V 00/V 00V 0V C-Frame Cat. No M-CT-A M-CT-A M-CT-A M-CT-A M-CT-B M-CT-B M-CT-B M-CT-B M-CT-B M-CT-C M-CT-C D-Frame M-DT-C M-DT-C0 F-Frame Cat. No. 0M-F. 0. 0M-FT-C M-FT-C Horsepower/kW ratings shown in the table above are for reference. The final selection of the MPCB depends on the actual motor full load current. - Publication A-CA00A-EN-P

4 Bulletin 0M Motor Protection Circuit Breakers Product Selection Motor Protection Circuit Breakers Screwless Short Circuit Protection Standard Magnetic Trip ( x I e ) Motor Overload Protection Trip Class Rated Operational Current (I e ) [A] Motor Current Adjustment Range [A] Magnetic Trip Current [A] Max. Short Circuit Current [ka] Max. -phase Hp Ratings Max. kw, -Phase AC- 00V (I cu ) 0V (group motor) 00V 0V 0V V 0V 00/V 00V 0V C-Frame Cat. No M-RCE-A M-RCE-A M-RCE-A M-RCE-A M-RCE-B M-RCE-B M-RCE-B M-RCE-B M-RCE-B M-RCE-C M-RCE-C Horsepower/kW ratings shown in the table above are for reference. The final selection of the MPCB depends on the actual motor full load current. Publication A-CA00A-EN-P -

5 Bulletin 0M Motor Circuit Protectors Product Overview Bulletin 0M Motor Circuit Protectors Current range A UL Listed/Recognized for motor loads Short-circuit protection Overload protection must be provided separately Visible trip indication High current limiting High switching capacity The Bulletin 0M Motor Circuit Protectors provide short circuit protection for individual motor loads. Factory-installed internal accessories make installation and wiring easy. Certifications (0. A) CE Marked culus Listed (File No. E, Guide No. NLRV, NLRV) CCC Certifications ( 00 A) UR Recognized component (File No. E, Guide DKPU) CSA Certified (Cleass No. -0) Table of Contents Product Selection Motor Circuit Protectors... - Approximate Dimensions... - Standards Compliance IEC/EN 0-,, --, -- IEC/EN 00- CSA, C. No. UL 0 UL (H-, J-, L-, N-Frame) General Information Motor Circuit Protectors may provide the following protective and control functions. Disconnect for Motor Branch Circuit Branch-Circuit, Short-Circuit Protection (Magnetic Protection) Switching (Manual) In North America, electrical codes require that an individual Motor Branch Circuit be protected by a UL/CSA Listed Fuse, Circuit Breaker or Self-Protected Combination Motor Controller. 0M-C, D and F Frames: The 0M-C, D and F frame Motor Circuit Protectors have one UL/CSA Listing as Manual Motor Controllers (with optional approvals for Motor Disconnect and Group Installation). In NEC/CEC Group Installations, these devices must be applied per the appropriate rules which require the use of an upstream Branch-Circuit, Short-Circuit Protective Device (BCPD). See the table on page -0 for the specific ratings of each Motor Circuit Protector. The 0M-C, D and F Frame Motor Circuit Protectors are also UL/CSA Listed, together with a Bulletin 0C contactor and Bulletin overload relay, as part of our Bulletin T and T Self-Protected IEC Combination Starters. These starters are then able to provide all of the necessary NEC/CEC requirements for the protection and control of individual Motor Branch Circuits without additional protective devices. 0M-H, J and L Frames: The 0M-H, J and L frame Motor Circuit Protectors are UL/CSA Recognized as Circuit Breakers as shown in the table on page -0. They are UL/CSA Recognized, rather than UL/CSA Listed, since they only provide short circuit protection and not thermal overload protection for the motor. 0M-H, J and L frame Motor Circuit Protectors (MCPs) are also UL/CSA Listed, together with a Bulletin 0C contactor and Bulletin overload relay, as part of our Bulletin IEC Combination Starters. These starters are then able to provide all of the necessary NEC/CEC requirements for the protection and control of individual Motor Branch Circuits without additional protective devices. - Publication A-CA00A-EN-P

6 Bulletin 0M Motor Circuit Protectors Product Overview/Catalog Number Explanation Product Line Overview C-Frame D-Frame F-Frame H-Frame J-Frame L-Frame N-Frame Max. Current I e A A A 0 A 0 A 00 A 00 A Current Rating 0.. A. A A Short Circuit Protection Standards Compliance: CSA., No. CSA., No. UL 0 (Group Install.) UL (Recognized) IEC 0- CE CCC (up to A) Accessories Ext. Rotary Operator Flex Cable Operator Auxiliary Contacts Trip Indication Contacts Cat. No. Explanation Examples given in this section are for reference purposes. This basic explanation should not be used for product selection; not all combinations will produce a valid catalog number. Code 0M Code C D F H J L N a Bulletin Number Motor Circuit Protectors (MCPs) b Frame Size and Rating A A A A 0 A 00 A and 00 A 00 A and 00 A Interrupting Rating / Breaking Capacity (I c at 0V) Code Normal Break High Break c 0M C N A KN CC GJ a b c d e f g h Code e Current Range Code Example A A =. A = 0. B B =.0 B =. C C = C = D D = 0 D = 0 E E = 00 E = 00 d Protection Type N Fixed Mag Only ( x I n ) P R Adj Mag Only (less than x I n ) - MCPs Adj Mag Only (greater than x I n ) - MCP's f, g, h Factory-Installed Options f Miscellaneous See page - g Aux/Trip Contacts See page - h UV and Shunt Trips See page - Publication A-CA00A-EN-P -

7 Bulletin 0M Motor Circuit Protectors Wiring Diagram Group Installation with MCPs There is only one Branch Circuit Protective Device (BCPD) for the Group Group installation has been successfully used for many years in the U.S. and Canada. It allows two or motors or one or more motors and other loads to be connected to the same branch-circuit. The most restrictive part of the conditions specified for Group Installation is the requirement for the protection of the conductors for each motor circuit. Below is an example that illustrates installations involving multiple motors with a single BCPD protecting the entire Group. Bulletin 0M Motor Circuit Protectors UL/CSA Listed for Group Installation Conductors from the BCPD to each motor must be a minimum of / the ampacity of the Branch Circuit conductors. Motor Circuit Protectors do not provide thermal protection, so a separate overload relay must be used. Therefore, MCPs cannot be UL/CSA Listed for Tap Conductor Protection in Group Installations. Bulletin 0M-C F Group Installation: Single Motor Taps Must be / the ampacity of the Branch-Circuit conductors Branch Circuit conductors BCPD Branch Circuit Protective Device Fuses or Circuit Breaker Group Motor Installation - Publication A-CA00A-EN-P

8 Bulletin 0M Motor Circuit Protectors Wiring Diagram -Phase Power Supply Multi-Motor Installation Publication A-CA00A-EN-P -

9 Bulletin 0M Motor Circuit Protectors Product Selection Motor Circuit Protectors Short circuit protection standard magnetic trip ( x I e ) Short circuit protection for component starters No motor overload protection separate Bulletin -E or -T product required for overload and installation protection For Trip Class motor applications Cat. No. 0M-C Cat. No. 0M-D Cat. No. 0M-F Rated Operational Current (I e ) [A] Magnetic Trip Current [A] Ultimate Interrupting Current [ka] Max. -phase Hp Ratings Max. kw, -Phase AC- 00V (I cu ) 0V (group motor) 00V 0V 0V V 0V 00/V 00V 0V C-Frame Cat. No M-CN-A M-CN-A M-CN-A M-CN-A M-CN-B M-CN-B M-CN-B D-Frame M-DN-B M-DN-B M-DN-B M-DN-C M-DN-C M-DN-C M-DN-C F-Frame M-FN-C M-FN-C M-FN-C Horsepower/kW ratings shown in the table above are for reference. The final selection of the manual starter depends on the actual motor full load current. Note: In applications with 0M-C_N, 0M-D_N and 0M-F_N as the short circuit protection device of heavy duty starting motors, the rated operational current I e of the above devices must be over-dimensioned with following factors: CLASS =.00 CLASS =. CLASS 0 =. CLASS =. CLASS 0 =. - Publication A-CA00A-EN-P

10 Bulletin 0M Motor Circuit Protectors Product Selection Motor Circuit Protectors Short-Circuit Protection Magnetic Trip (Adjustable at... x I e ) Overload Protection None (Magnetic Trip Only) Rated Operational Current (I e ) [A] Cat. No. 0M-H Cat. No. 0M-J Cat. No. 0M-L Magnetic Trip Current [A] Cam Setting -phase Hp Ratings Max. kw, -Phase AC- A B C D E F G H I 00V 0V 0V V 0V 00/V 00V 0V H-Frame Cat. No M-HP-B M-HP-B M-HP-C M-HP-C M-HP-C M-HP-C M-HP-D M-HR-D J-Frame M-JP-D M-JP-D M-JP-D M-JP-D M-JP-D M-JP-D M-JP-D L-Frame M-LP-D M-LP-D M-LP-D M-LP-D M-LP-D M-LP-D M-LP-D M-LP-D0 N-Frame M-NP-D M-NP-E The Hp and kw ratings shown are for reference only. They allow for a magnetic trip setting of at least up to X the motor FLA. However, the final selection of the MCP should be made based on motor full load current and the requirements of local electrical codes. The interrupting rating for MCPs is dependent upon the controller used. Please contact your local Rockwell Automation sales office or Allen-Bradley distributor for further information. Publication A-CA00A-EN-P -

11 Bulletin 0M Application Ratings UL/CSA Listed Application Ratings Motor Protection Circuit Breaker (MPCB) Only - Cat. No. Max. Fuse or C.B. per NEC Group Motor Installation Max. Short Circuit Current [ka] UL 0 Manual Motor Controller Motor Disconnect Max. Short Circuit Current [ka] Tap Conductor Protection Max. Short Circuit Current [ka] Publication A-CA00A-EN-P UL 0 Self-Protected (Type E) Combination Motor Controller Max. Short Circuit Current [ka] UL Inverse Time C.B. w/ul 0 Motor Overload Protection Max. Short Circuit Current [ka] 0V 00V 0V 00V 0V 00V 0Y/V 00Y/V 0V 00V C-Frame 0M-CE-A 0 0M-CE-A 0 0M-CE-A0 0 0M-CE-A 0 0M-CE-B 0 0M-CE-B 0 0M-CE-B M-CE-B0 0 0M-CE-B M-CE-C M-CE-C M-CE-C M-CE-C 0 0M-CE-C 0 0M-CE-C 0 D-Frame 0M-DE-B M-DE-B M-DE-B M-DE-C M-DE-C M-DE-C M-DE-C M-DE-C M-DE-C F-Frame 0M-FE-C M-FE-C M-FE-C M-FE-C M-FE-C M-FE-C 00 CMN-Frame 0-CMN CMN CMN CMN I-Frame 0M-IE-C0 0 0M-IE-D 0 0M-IE-D 0 0M-IE-D0 0 J-Frame 0M-JE-C0 0M-JE-D 0M-JE-D 0M-JE-D 0M-JE-C0 0M-JE-D 0M-JE-D 0M-JE-D L-Frame 0M-LE-D 0M-LE-D0 0M-LE-D 0M-LE-D 0M-LE-D0 0M-LE-D For full voltage (delta) ratings above V or V, follow the NEC or CEC rules for group motor applications.

12 Bulletin 0M Application Ratings UL/CSA Listed Application Ratings Motor Protection Circuit Breaker (MPCB) Only, Continued Cat. No. Max. Fuse or C.B. per NEC UL 0 Manual Motor Controller Group Motor Installation Motor Disconnect Tap Conductor Protection Max. Short Circuit Current [ka] Max. Short Circuit Current [ka] Max. Short Circuit Current [ka] UL 0 Self-Protected (Type E) Combination Motor Controller Max. Short Circuit Current [ka] 0V 00V 0V 00V 0V 00V 0Y/V 00Y/V C-Frame 0M-CT-A 0 0M-CT-A 0 0M-CT-A0 0 0M-CT-A 0 0M-CT-B 0 0M-CT-B M-CT-B 0 0M-CT-B M-CT-B M-CT-C M-CT-C D-Frame 0M-DT-C M-DT-C F-Frame 0M-FT-C M-FT-C 00 For full voltage (delta) ratings above V or V, follow the NEC or CEC rules for group motor applications. Publication A-CA00A-EN-P -

13 Bulletin 0M Application Ratings UL Listed Application Ratings Motor Circuit Protectors Only Cat. No. Max. Fuse or C.B. per NEC UL 0 Manual Motor Controller UL Instantaneous Trip Circuit Breaker (Magnetic Only) Group Motor Installation Motor Disconnect Motor Circuit Protector Max. Short Circuit Current [ka] Max. Short Circuit Current [ka] Max. Short Circuit Current [ka] 0V 00V 0V 00V 0V 00V C-Frame 0M-CN-A 0 0M-CN-A 0 0M-CN-A0 0 0M-CN-A 0 0M-CN-B 0 0M-CN-B 0 0M-CN-B D-Frame 0M-DN-B M-DN-B M-DN-B M-DN-C M-DN-C M-DN-C M-DN-C F-Frame 0M-FN-C M-FN-C M-FN-C 00 H-Frame 0M-HP-B0 0 0M-HP-B0 0 0M-HP-C 0 0M-HP-C0 0 0M-HP-C0 0 0M-HP-C0 0 0M-HP-D 0 0M-HR-D 0 J-Frame 0M-JP-C0 0 0M-JP-C0 0 0M-JP-D 0 0M-JP-D 0 0M-JP-D 0 0M-JP-D 0 0M-JP-D0 0 0M-JP-D 0 0M-JP-D 0 L-Frame 0M-LP-D 0 0M-LP-D 0 0M-LP-D0 0 0M-LP-D 0 0M-LP-D0 0 0M-LP-D 0 0M-LP-D0 0 0M-LP-D0 0 N-Frame 0M-NP-D0 0M-NP-E Separate overload protection is required. The interrupting rating for MCPs is dependent upon the controller used. Contact your local Rockwell Automation sales office or Allen-Bradley distributor for further information. -0 Publication A-CA00A-EN-P

14 Bulletin 0M Application Ratings UL Listed Application Ratings - Motor Protection Circuit Breakers with Bulletin 0-K Contactors Cat. No. Max. Fuse or C.B. per NEC UL 0 Manual Motor Controller Minimum Contactor Size Group Motor Installation Max. Short Circuit Current [ka] Motor Disconnect Max. Short Circuit Current [ka] UL 0 Type F Combination Motor Controller UL 0 Type E Self-Protected Combination Motor Controller Minimum Max. Short Circuit Current Minimum Max. Short Circuit Current Contactor [ka] Contactor [ka] 0V 00V 0V 00V Size 0Y/V 00Y/V Size 0Y/V 00Y/V C-Frame 0M-CE-A 0 0-K0 0-K0 0M-CE-A 0 0-K0 0-K0 0M-CE-A0 0 0-K0 0-K0 0M-CE-A 0 0-K0 0-K0 0M-CE-B 0 0-K0 0-K0 0M-CE-B 0 0-K0 0-K0 0M-CE-B 0 0-K K0 0 0M-CE-B0 0 0-K K0 0 0M-CE-B 0 0-K K0 0M-CE-C 0 0-K K0 0M-CE-C 0 0-K K 0 D-Frame 0M-DE-B 0 0-K K0 0 0M-DE-B0 0 0-K K0 0 0M-DE-B 0 0-K K0 0 0M-DE-C 0 0-K K0 0 0M-DE-C 0 0-K K 0 For full voltage (delta) ratings above V or V, follow the NEC or CEC rules for group motor applications. Publication A-CA00A-EN-P -

15 Bulletin 0M Application Ratings UL Listed Application Ratings - Motor Protection Circuit Breakers with Bulletin 0-C Contactors Cat. No. Max. Fuse or C.B. per NEC UL 0 Manual Motor Controller Minimum Contactor Size Group Motor Installation Max. Short Circuit Current [ka] Motor Disconnect Max. Short Circuit Current [ka] UL 0 Type F Combination Motor Controller UL 0 Type E Self-Protected Combination Motor Controller Minimum Max. Short Circuit Current Minimum Max. Short Circuit Current Contactor [ka] Contactor [ka] 0V 00V 0V 00V Size 0Y/V 00Y/V Size 0Y/V 00Y/V C-Frame 0M-CE-A 0 0-C0 0-C0 0-C0 0M-CE-A 0 0-C0 0-C0 0-C0 0M-CE-A0 0 0-C0 0-C0 0-C0 0M-CE-A 0 0-C0 0-C0 0-C0 0M-CE-B 0 0-C0 0-C0 0-C0 0M-CE-B 0 0-C0 0-C0 0-C0 0M-CE-B 0 0-C C0 0 0-C0 0 0M-CE-B0 0 0-C C0 0 0M-CE-B 0 0-C C0 0M-CE-C 0 0-C C0 0M-CE-C 0 0-C C 0 0 0M-CE-C0 0 0-C C 0M-CE-C 0 0-C C M-CE-C 0 0-C0 0M-CE-C 0 0-C 0M-DE-B D-Frame 0 0-C C0 0 0-C0 0 0-C 0 0M-DE-B0 0 0-C C0 0 0-C 0 0M-DE-B 0 0-C C0 0 0-C0 0 0M-DE-C 0 0-C C0 0 0-C0 0 0M-DE-C 0 0-C C 0 0-C0 0 0M-DE-C0 0 0-C C 0-C0 0M-DE-C 0 0-C C 0 0-C0 0 0M-DE-C 0 0-C0 0M-DE-C 0 0-C F-Frame 0M-FE-C 00 0-C C0 0 0-C0 0 0M-FE-C 00 0-C C0 0 0-C0 0 0M-FE-C C C0 0 0-C0 0 0M-FE-C 00 0-C C0 0 0-C0 0 0M-FE-C 00 0-C C0 0 0-C0 0 0M-FE-C 00 0-C 0-C 0-C CMN-Frame 0-CMN C 0-CMN C0 0-CMN C 0-CMN C For full voltage (delta) ratings above V or V, follow the NEC or CEC rules for group motor applications. - Publication A-CA00A-EN-P

16 Bulletin 0M Application Ratings UL Listed Application Ratings - Motor Circuit Protectors with Bulletin 0-C Contactors Cat. No. Max. Fuse or C.B. per NEC Minimum Contactor Size UL 0 Manual Motor Controller Group Motor Installation Motor Disconnect UL 0 Type E (Self-Protected) Combination Motor Controller Max. Short Max. Short Max. Short Circuit Current Max. Short Circuit Current Circuit Circuit Minimum [ka] [ka] Current [ka] Current [ka] Contactor 0V 00V 0V 00V Size 0Y/V 00Y/V C-Frame 0M-CN-A 0 0-C0 0-C0 0M-CN-A 0 0-C0 0-C0 0M-CN-A0 0 0-C0 0-C0 0M-CN-A 0 0-C0 0-C0 0M-CN-B 0 0-C0 0-C0 0M-CN-B 0 0-C0 0-C0 0M-CN-B 0 0-C C0 0M-DN-B D-Frame 0 0-C C0 0-C 0 0M-DN-B0 0 0-C C 0 0M-DN-B 0 0-C C0 0 0M-DN-C 0 0-C C0 0 0M-DN-C 0 0-C C0 0 0M-DN-C 0 0-C C0 0M-DN-C 0 0-C F-Frame 0M-FN-C 00 0-C C0 0 0M-FN-C 00 0-C C0 0 0M-FN-C 00 0-C 0-C Separate overload protection is required. For full-voltage (delta) ratings above V or V, follow the NEC or CEC rules for group motor applications. Publication A-CA00A-EN-P -

17 Bulletin 0M Motor Circuit Protectors Application Ratings Definition of Type Short Circuit Coordination: The contactor or starter must not endanger persons or plant in the event of a short circuit. No damage to the motor protection device or other parts may occur with the exception of welding of the contactor or starter contacts if these can be easily separated without appreciable deformation (such as with a screwdriver). In the event of short circuit, fast-opening, current-limiting Bulletin 0M Motor Protection Circuit Breakers make it possible to build economical, fully short-circuit coordinated starter combinations with Type coordination. Type Coordination 00V Cat. No. Max. Short Circuit Current [ka] For Use With Contactors Standard Motor Protection High Inrush Motor Protection Motor Circuit Protection 00V Below (or larger) C-Frame 0M-CE-A 0M-CN-A 0 0-C0 0M-CE-A 0M-CT-A 0M-CN-A 0 0-C0 0M-CE-A0 0M-CT-A 0M-CN-A0 0 0-C0 0M-CE-A 0M-CT-A0 0M-CN-A 0 0-C0 0M-CE-B 0M-CT-A 0M-CN-B 0 0-C0 0M-CE-B 0M-CT-B 0M-CN-B 0 0-C0 0M-CE-B 0M-CT-B 0M-CN-B 0 0-C0 0M-CE-B0 0M-CT-B 0 0-C0 0M-CE-B 0M-CT-B0 0 0-C0 0M-CE-C 0M-CT-B 0 0-C0 0M-CE-C 0M-CT-C 0 0-C 0M-CE-C0 0M-CT-C 0 0-C 0M-CE-C 0-C0 0M-CE-C 0-C0 0M-CE-C 0-C D-Frame 0M-DE-B 0M-DN-B 0 0-C0 0M-DE-B0 0M-DN-B0 0 0-C0 0M-DE-B 0M-DN-B 0 0-C0 0M-DE-C 0M-DN-C 0-C0 0M-DE-C 0M-DN-C 0-C 0M-DE-C0 0M-DT-C 0-C 0M-DE-C 0M-DT-C0 0M-DN-C 0 0-C 0M-DE-C 0-C0 0M-DE-C 0M-DN-C 0-C F-Frame 0M-FE-C 0 0-C0 0M-FE-C 0 0-C 0M-FE-C0 0 0-C 0M-FE-C 0M-FN-C 0 0-C0 0M-FE-C 0M-FT-C 0M-FN-C 0 0-C0 0M-FE-C 0M-FT-C 0M-FN-C 0 0-C CMN-Frame 0-CMN-00 0-C 0-CMN C0 0-CMN-00 0-C 0-CMN C Cat. No. 0-C contactors Type only - Publication A-CA00A-EN-P

18 Bulletin 0M Motor Circuit Protectors Application Ratings Type Coordination 0V Cat. No. Max. Short Circuit Current [ka] Standard Motor Protection High Inrush Motor Protection Motor Circuit Protection 0V C-Frame For Use With Contactors Below (or larger) 0M-CE-A 0M-CN-A 0-C0 0M-CE-A 0M-CT-A 0M-CN-A 0-C0 0M-CE-A0 0M-CT-A 0M-CN-A0 0-C0 0M-CE-A 0M-CT-A0 0M-CN-A 0-C0 0M-CE-B 0M-CT-A 0M-CN-B 0-C0 0M-CE-B 0M-CT-B 0M-CN-B 0-C0 0M-CE-B 0M-CT-B 0M-CN-B 0 0-C 0M-CE-B0 0M-CT-B 0 0-C0 0M-CE-B 0M-CT-B0 0 0-C0 0M-CE-C 0M-CT-B 0 0-C0 0M-CE-C 0M-CT-C 0-C0 0M-CE-C0 0M-CT-C 0-C0 0M-CE-C 0-C0 0M-CE-C 0-C0 0M-CE-C 0-C D-Frame 0M-DE-B 0M-DN-B 0-C0 0M-DE-B0 0M-DN-B0 0-C0 0M-DE-B 0M-DN-B 0-C0 0M-DE-C 0M-DN-C 0-C0 0M-DE-C 0M-DN-C 0-C 0M-DE-C0 0M-DT-C 0-C 0M-DE-C 0M-DT-C0 0M-DN-C 0-C 0M-DE-C 0-C0 0M-DE-C 0M-DN-C 0-C F-Frame 0M-FE-C 0-C0 0M-FE-C 0-C 0M-FE-C0 0-C 0M-FE-C 0M-FN-C 0-C0 0M-FE-C 0M-FT-C 0M-FN-C 0-C0 0M-FE-C 0M-FT-C 0M-FN-C 0-C CMN-Frame 0-CMN-00 0-C 0-CMN C0 0-CMN-00 0-C 0-CMN C Publication A-CA00A-EN-P -

19 Bulletin 0M Motor Circuit Protectors Application Ratings Type Coordination 00V Cat. No. Max. Short Circuit Current [ka] Standard Motor Protection High Inrush Motor Protection Motor Circuit Protection 00V C-Frame For Use With Contactors Below (or larger) 0M-CE-A 0M-CN-A 0-C0 0M-CE-A 0M-CT-A 0M-CN-A 0-C0 0M-CE-A0 0M-CT-A 0M-CN-A0 0-C0 0M-CE-A 0M-CT-A0 0M-CN-A 0-C0 0M-CE-B 0M-CT-A 0M-CN-B 0-C0 0M-CE-B 0M-CT-B 0M-CN-B 0-C0 0M-CE-B 0M-CT-B 0M-CN-B 0-C 0M-CE-B0 0M-CT-B 0-C 0M-CE-B 0M-CT-B0 0-C 0M-CE-C 0M-CT-B 0-C0 0M-CE-C 0M-CT-C 0-C0 0M-CE-C0 0M-CT-C 0-C0 0M-CE-C 0-C0 0M-CE-C 0-C0 0M-CE-C 0-C D-Frame 0M-DE-B 0M-DN-B 0 0-C0 0M-DE-B0 0M-DN-B0 0 0-C0 0M-DE-B 0M-DN-B 0 0-C0 0M-DE-C 0M-DN-C 0 0-C0 0M-DE-C 0M-DN-C 0 0-C0 0M-DE-C0 0M-DT-C 0-C0 0M-DE-C 0M-DT-C0 0M-DN-C 0-C0 0M-DE-C 0-C0 0M-DE-C 0M-DN-C 0-C F-Frame 0M-FE-C 0 0-C0 0M-FE-C 0 0-C0 0M-FE-C0 0 0-C0 0M-FE-C 0M-FN-C 0 0-C0 0M-FE-C 0M-FT-C 0M-FN-C 0 0-C0 0M-FE-C 0M-FT-C 0M-FN-C 0-C CMN-Frame 0-CMN-00 0-C 0-CMN C0 0-CMN-00 0-C 0-CMN C - Publication A-CA00A-EN-P

20 Bulletin 0M Accessories Operator Position OFF ON Tripped Term. No. Connection Diagram For Use With Cat. No. O X O - N.O. Aux 0M-C, D, F; 0M-C-AFA X O X - N.C. Aux 0U-D (UL only in combination with 0M-C- AFC) 0M-C-AFA0 Front-Mounted Auxiliary Contact -pole or -pole No additional space required Only per device O X O - N.O. Aux X O X - N.C. Aux O X O - N.O. Aux O X O - N.O. Aux 0M-C, D, F; 0U-D (UL only in combination with 0M-C- AFC) 0M-C-AFA 0M-C-AFA0 X O X - N.C. Aux X O X - N.C. Aux 0M-C-AFA0 O X O - N.O. Aux O X O - N.O. Aux 0M-C, D, F 0M-C-ASA0 Right Side-Mounted Auxiliary Contact -pole Adds mm to the width of the device Two per MPCB X O X - N.C. Aux X O X - N.C. Aux 0M-C, D, F 0M-C-ASA0 O X O - N.O. Aux X O X - N.C. Aux 0M-C, D, F 0M-C-ASA X = Contact Closed; O = Contact Open 0M Operator Overload (thermal) Trip Short-Circuit (magnetic) Trip Publication A-CA00A-EN-P -

21 Bulletin 0M Accessories Front-Mounted Trip Contact -pole Indicates tripping of device No additional space required Right-Side Mounted Trip Contact -pole Indicates tripping of motor protection circuit breaker Adds mm to the width of the circuit breaker One only per MPCB A right-side mounted auxiliary contact may be tandem mounted on top of this trip contact Operator Position OFF ON Tripped Term. No. O X O - N.O. Aux O O X - N.O. Trip (Short-Circuit & Overload) X O X - N.C. Aux O O X - O O X - O O X - O O X - X X O - X X O - O O X - X X O - X X O - Connection Diagram For Use With Cat. No. N.O. Trip (Short-Circuit & Overload) N.O. Trip (Short-Circuit & Overload) N.O. Trip (Short-Circuit) I>> N.O. Trip (Short-Circuit & Overload) N.C. Trip (Short-Circuit) N.C. Trip (Short-Circuit & Overload) N.O. Trip (Short-Circuit) N.C. Trip (Short-Circuit & Overload) N.C. Trip (Short-Circuit) I>> 0M-C, D, F; 0U-D (UL only in combination with 0M-C-AFC) 0M-C, D, F 0M-C, D, F 0M-C, D, F 0M-C, D, F 0M-C-AFARA 0M-C-AFARA0 0M-C-ASARM 0M-C-ASARM0 0M-C-ASAR0M 0M-C-ASAR0M0 O O X - X X O - N.O. Trip (Short-Circuit) N.C. Trip (Short-Circuit) 0M-C, D, F 0M-C-ASAM X = Contact Closed; O = Contact Open 0M Operator Overload (thermal) Trip Short-Circuit (magnetic) Trip - Publication A-CA00A-EN-P

22 Bulletin 0M Accessories Accessories Screwless Operator Position OFF ON Tripped Term. No. Connection Diagram For Use With Cat. No. O X O - N.O. Aux 0M-RC-AFA Front-Mounted Auxiliary Contact -pole or -pole No additional space required - Only per MPCB 0M-C, D, F; 0M-RC X O X - N.C. Aux 0M-RC-AFA0 O X O - N.O. Aux X O X - N.C. Aux O X O - N.O. Aux 0M-C, D, F; 0M-RC 0M-RC-AFA O X O - N.O. Aux 0M-RC-AFA0 Front-Mounted Trip Contact -pole Indicates tripping of device No additional space required O X O - N.O. Aux O O X - N.O. Trip (Short-Circuit & Overload) X O X - N.C. Aux O O X - N.O. Trip (Short-Circuit & Overload) 0M-C, D, F; 0M-RC 0M-RC- AFARA0 0M-RC- AFARA X = Contact Closed; O = Contact Open 0M Operator Overload (thermal) Trip Short-Circuit (magnetic) Trip Publication A-CA00A-EN-P -

23 Bulletin 0M Accessories Operator Position OFF ON Tripped Term. No. Connection Diagram For Use With Cat. No. O X O - N.O. Aux 0-CMN 0-CA0 O X O - N.O. Aux Front-Mounted Auxiliary Contact Internal -pole per MPCB X O X - N.C. Aux X O X - N.C. Aux 0-CMN 0-CA0 0-CMN 0-CA0 O X O - N.O. Aux X O X - N.C. Aux 0-CMN 0-CA O O X - O O X - N.O. Trip (Overload) N.O. Trip (Short-Circuit) a) Overload Trip b) Short-Circuit Trip 0-CMN 0-CT- X X O - N.C. Trip (Overload) 0-CMN 0-CT0-0 Front-Mounted Trip- Indicating Auxiliary Contact Internal -pole per MPCB X X O - X X O - N.C. Trip (Short-Circuit) N.C. Trip (Overload) a) Overload Trip b) Short-Circuit Trip O O X - N.O. Trip (Short-Circuit) a) Overload Trip b) Short-Circuit Trip 0-CMN 0-CT0- O O X - X X O - N.O. Trip (Overload) N.C. Trip (Short-Circuit) a) Overload Trip b) Short-Circuit Trip 0-CMN 0-CT-0 X = Contact Closed O = Contact Open 0M Operator Overload (thermal) Trip Short-Circuit (magnetic) Trip -0 Publication A-CA00A-EN-P

24 Bulletin 0M Accessories Connection Diagram Trip Rating For Use With Cat. No. V, 0 Hz 0M-C-UXJ V, 0 Hz 0M-C-UXK 0V, 0 Hz 0M-C-UXD Undervoltage Trip V, 0 Hz 0M-C-UXC Left-side mounted Adds mm to the width 0V, 0 Hz 0M-C-UXH of the circuit breaker 0 0V, 0 Hz 0M-C-UXF 0M-C, D, F Automatically trips 0 0V, 0 Hz 0M-C-UXA MPCB/MCP when voltage falls below V, 0 Hz 0M-C-UXT 0% 0 00V, 0 Hz 0M-C-UXN 0V, 0 Hz/V, 0 Hz 0M-C-UXB V, 0 Hz/00V, 0 Hz 0M-C-UXM 00V, 0 Hz 0M-C-UXVC V, 0 Hz 0M-C-UCJ V, 0 Hz 0M-C-UCK Undervoltage Trip 0V, 0 Hz 0M-C-UCD Left-side mounted V, 0 Hz 0M-C-UCC early make contacts integrated 0V, 0 Hz 0M-C-UCH Adds mm to the width 0 0V, 0 Hz 0M-C-UCF 0M-C, D, F of the circuit breaker 0 0V, 0 Hz 0M-C-UCA Automatically trips MPCB/MCP when V, 0 Hz 0M-C-UCT voltage falls below 0 00V, 0 Hz 0M-C-UCN 0% 0V, 0 Hz/V, 0 Hz 0M-C-UCB V, 0 Hz/00V, 0 Hz 0M-C-UCM 00V, 0 Hz 0M-C-UCVC V, 0 Hz 0M-C-SNJ V, 0 Hz 0M-C-SNK V, 0 Hz/0V, 0 Hz 0M-C-SND 0V, 0 Hz 0M-C-SNH Shunt Trip Left-side mounted 0 0V, 0 Hz 0M-C-SNF Adds mm to the width 0 0V, 0 Hz 0M-C-SNA 0M-C, D, F of the circuit breaker V, 0 Hz 0M-C-SNT Provides remote tripping of the MPCB/MCP 0 00V, 0 Hz 0M-C-SNN 0V, 0 Hz/V, 0 Hz 0M-C-SNB V, 0 Hz/00V, 0 Hz 0M-C-SNM 00V, 0 Hz 0M-C-SNVC V DC 0M-C-SNZJ Undervoltage Trip Unit Internal, front-mounted Integrated short-circuit trip indication Automatically trips MPCB when voltage falls below 0% b) Short-Circuit Trip V, 0/0 Hz 0-CUV-KJ V, 0 Hz/0V, 0 Hz 0-CMN 0-CUV-D 0V, 0 Hz/0V, 0 Hz 0-CUV-A Shunt Trip Unit Internal, front-mounted Integrated short-circuit trip indication Provides remote tripping of the MPCB b) Short-Circuit Trip V, 0/0 Hz 0-CRT-KJ V, 0 Hz/0V, 0 Hz 0-CMN 0-CRT-D 0V, 0 Hz/0V, 0 Hz 0-CRT-A 0M Operator Overload (thermal) Trip Short-Circuit (magnetic) Trip Publication A-CA00A-EN-P -

25 Bulletin 0M Accessories For Use With Cat. No. Anti-Tamper Shield Provides protection against inadvertent adjustment of the current setting pcs/pkg 0M-C, D, F 0M-C-CA Lockable Twist Knob For one padlock mm (/ in.) Ø shackle Can be locked in OFF position Locking Tag Padlock attachment to the lockable handles Up to three padlocks mm (/ in.) Ø shackle Black Red/Yellow 0M-C, D, F; 0U-D 0M-C-KN, 0M-C-KRY 0M-C-KN 0M-C-KRY 0M-C-M Padlockable Operating Knob Accepts mm (/ in.) Ø padlock shackle up to three padlocks Permits padlocking in the off position Door Coupling Handle For padlocks mm (/ in.) in diameter IP Protection/Type,, X, Interlock override capability Can be modified for locking in ON position Ships with coupling order extension shaft and legend plate separately Mounting depth (front of DIN Rail to front of enclosure door): - 0M-C:. mm ± mm (. in. ± / in.) - 0M-D:. mm ± mm (. in. ± / in.) - 0M-F:. mm ± mm (. in. ± / in.) - 0-CMN: mm +/- mm (. in. +/- / in.) Legend Plate Marking: "Hauptschalter" and "Main Switch" Marking: "Not-Aus" and "Emergency Off" Extension Shaft Cut to required length for mounting depth (front of DIN Rail to front of enclosure door): - 0M-C: mm (... in.) - 0M-D: mm (.0.. in.) - 0M-F: mm (... in.) - 0-CMN: 0 0 mm (... in.) Extension Shaft (Extended Length) Cut to required length for mounting depth (front of DIN Rail to front of enclosure door): - 0M-C: mm (.. in.) - 0M-D: mm (.0. in.) - 0M-F: mm (. 0. in.) - 0-CMN: 0 mm (.. in.) Black Red/Yellow Black Red/Yellow 0-CMN 0M-C, D, F 0-CMN 0M-C, D, F 0-CMN 0-CDN 0-CDRY 0M-C-DN, 0M-C-DRY, 0-CDN, 0-CDRY 0M-C-DN, 0M-C-DRY, 0-CDN, 0-CDRY 0-KN 0-KRY 0M-C-DN 0-CDN 0M-C-DRY 0-CDRY 0M-C-DFCN 0M-C-DFCRY 0M-C-DS 0M-C-DSL Coupler Included with Cat. Nos. 0M-C-DN and 0M-C-DRY 0M-C, D, F; 0U-D 0M-C-DNC IP Non-Metallic Enclosure Knockouts for M0 and M fittings Suitable for flexible cable with internal ground wire or conduit when externally grounded around the outside of the enclosure (no UL/CSA approval) Black Handle Red/Yellow Handle 0M-C 0M-C E-AYTG E-AYTJ Screw Adapter For screw arrangement of a motor protection circuit breaker pcs/pkg 0M-C, D, F; 0U-D 0M-C-N - Publication A-CA00A-EN-P

26 Bulletin 0M Accessories For Use With Cat. No. ECO Connecting Module A For DOL and reversing starters Eco-starters mount on single DIN Rail (0M on DIN Rail) Electrical and mechanical interconnection of 0M and 0-K contactors ECO Connecting Modules A Eco-starters mount on single DIN Rail (0M on DIN Rail) Electrical and mechanical interconnection of 0M MPCB and 0-C (with AC coils or V DC electronic coils) contactors ECO Connecting Modules A Eco-starters mount on single DIN Rail (0-C on DIN Rail) Electrical and mechanical interconnection of 0M MPCB and 0-C (with AC or DC coils) Connecting Modules and A Contactor and MPCB MUST BE mounted separately on () DIN Rails Electrical and mechanical interconnection of 0M and 0-C (with AC coils) Coil Modules A and A For use with Bulletin T/T -component starters Spacing Adapter Required for self-protected combination motor controller (Type E) applications of Bul. 0M-C, -D, and -F MPCBs. Not for use with bus bars. 0M-C to 0-K 0M-C to 0-C0 C 0M-D to 0-C0 C 0M-C, 0M-D to 0- C0 C 0M-C to 0-C0 C 0M-D to 0-C0 C 0M-D to 0-C0 C 0M-F to 0-C0 C 0M-F to 0-C 0M-C, -D to 0- C0 C 0M-D, -F to 0- C0 C 0M-C, -D 0M-F 0M-C-PEK 0M-C-PEC 0M-D-PEC 0M-C-PECA 0M-C-PNC 0M-D-PNC 0M-D-PNC 0M-F-PNC 0M-F-PNC 0M-C-PSC 0M-F-PSC 0M-C-TE 0M-F-TE Feeder Block for Compact Busbar Supply of compact busbars Increases terminal capacity 0M-C 0M-F 0M-C-WBE 0M-F-WBE Feeder Terminal for Compact Busbar For supply of compact busbars Top feed overlaps compact busbar Meets IEC spacing requirements Feeder Terminal for Compact Busbar For supply of compact busbars Top feed overlaps compact busbar Meets UL Type E spacing requirements Three-Phase Compact Busbar for A Motor Protection Circuit Breakers A Max. Continuous Current mm spacing For use with front-mounted auxiliary contact Three-Phase Compact Busbar for A Motor Protection Circuit Breakers A Max. Continuous Current mm spacing For use with side-mounted auxiliary contact Three-Phase Compact Busbar for A Motor Protection Circuit Breakers A Max. Continuous Current mm spacing For use with front-mounted auxiliary contact Three-Phase Compact Busbar for A Motor Protection Circuit Breakers A Max. Continuous Current mm spacing For use with side-mounted auxiliary contact Terminal Cover For covering of unused compact bus bar terminals IPX finger protection 0M-C, -D 0M-C, -D 0M-F 0M-C-WTN 0M-C-WTEN 0M-F-WTE connections 0M-C-WN connections 0M-C-WN 0M-C, -D connections 0M-C-WN connections 0M-C-WN connections 0M-C-WN connections 0M-C-WN 0M-C, -D connections 0M-C-WN connections 0M-C-WN connections 0M-F-W connections 0M-F 0M-F-W connections 0M-F-W connections 0M-F-W connections 0M-F 0M-F-W connections 0M-F-W 0M-C, 0M-D 0M-C-WSN 0M-F 0M-F-WS Top Hat Rail Adpapter mm Adjusts the depth of the 0M-C to the 0M-D Allows the use of compact busbars accross both frame sizes Must be ordered in multiples of 0M-C 0-KBH Notes:. See Bulletin 0U for Internal and External Accessories for Bulletin 0M-H, J, L and N frames.. Bulletin 0M-I frame Accessories such as auxiliaries, alarms, undervoltage and shunt trips are only available as factory installed modifications. See page -. Publication A-CA00A-EN-P -

27 Bulletin 0M Accessories For Use With Pkg. Quantity Cat. No. Terminal End Cover 0. in. 0U-I-TC 0M-I Terminal End Cover 0. in. 0U-I-TC Terminal Shields (Plastic) IP0 Ingress Protection Padlockable Handle Lock Hasp Off only Padlocking Hasp Lock-OFF only End Cap Kit Provides -phase connections for terminal or bolt-on connections Metric Hardware Phase Barriers Provides additional phase clearance when special connections are required 0M-I 0U-I-TS 0M-I 0U-I-PL 0M-I 0U-I-ECM 0M-I 0U-I-PB Terminal Lugs Steel Terminal Copper/Aluminum wire #-/0 AWG Terminal Lugs Stainless Steel Terminal Copper/Aluminum wire #-/0 AWG Rotary Close Couple Handle International Black handle Rotary Close Couple Handle International Red/Yellow handle 0M-I 0M-I 0U-I-TLS 0U-I-TLS 0U-I-RCB 0U-I-RCR Operating Mechanism for External Handles 0M-I -H External Handles Black/Grey IP (Type /R//X/) Red/Yellow IP (Type /R//X/) Black/Grey IP (Type ) Red/Yellow IP (Type ) 0M-I 0-HM 0-HME 0-HM 0-HME Overload Pre-trip Auxiliary Contact (AX) Opens contactor coil circuit on overload before MPCB trips (Automatic reset) 0M-J, -L (MPCB only) 0U-J-ERRX - Publication A-CA00A-EN-P

28 Bulletin 0M Accessories For Use With Pkg. Quantity Cat. No. Extension Shafts Standard Enclosure Working Depth [mm (in.)] Minimum 0 () R-R Maximum 0 () 0M-I Extended Minimum 0 () R-R Maximum 0 (0) Flex-Cable Operating ft. (0. m) Cable 0U-I-FCX0 Mechanism ft. (. m) Cable 0U-I-FCX0 NEMA Type ////X ft. (. m) Cable 0U-I-FCX0 Flange-Mount Handle ft. (.0 m) Cable 0U-I-FCX Flex-Cable Operating ft. (0. m) Cable 0M-I 0U-I-FCS0 Mechanism ft. (. m) Cable 0U-I-FCS0 Stainless Steel - Type /X ft. (. m) Cable 0U-I-FCS0 Flange Mount Handle ft. (.0 m) Cable 0U-I-FCS DIN (#) symmetrical hat rail x. x m 0M-D 0M-F 0-C all pcs/kg -DR DIN (#) Symmetrical Rail mm x mm x m long Top Hat Rail (DIN # Symmetrical Rail) 0M-C 0M-D 0M-F 0-CMN pcs/kg -DR Publication A-CA00A-EN-P -

29 Bulletin 0M Modifications 0M Factory Modifications (Open) Note: For modifications add (option code _) for desired features to cat. no. Available in North America only. f Miscellaneous Code Frame Size KN() Black Lockable Knob C, D, F, CMN KRY() Red/Yellow Lockable Knob C, D, F, CMN TE() Spacing Adapter for Self- Protected Starters (Type E) C, D, F MT STD Bus Bar Mount, Top C, D, F, H, CMN MU STD Bus Bar Mount, Universal J, K, L st Code st Code X Bottom Front Bottom Front Placeholder Only available on MCPs. J- and L-Frame MPCB only. g Aux / Trip Contacts - C, D, F g nd Code Aux / Trip Contacts - H, J, L nd Code X C R F N T Right Side X Placeholder X Placeholder A N.C. C N.O. + N.C. B N.O. D N.O. C N.O. + N.C. E N.C. D N.O. K N.C. (SC+OL) + N.C. (SC) E N.C. L N.O. (SC+OL) + N.O. (SC) R N.C. + N.O. (SC+OL) M N.C. (SC+OL) + N.O. (SC) S N.O. + N.O. (SC+OL) N N.O. (SC+OL) + N.C. (SC) st Code Bottom Front g Q Aux / Trip Contacts - CMN nd Code N.O. (SC) + N.C. (SC) Top Front X Placeholder X Placeholder C N.O. + N.C. K N.C. (OL) + N.C. (SC) D N.O. L N.O. (OL) + NO (SC) E N.C. M N.C. (OL) + N.O. (SC) Cannot be combined with option "h". N N.O. (OL) + N.C. (SC) Right Side Placeholder N.O. + N.C. N.O. + N.C. (Overload Function) N.O. + N.C. N.O. (SC+OL) + N.C. (SC) N.O. + N.C. and N.O. + N.C. (SC+OL) st Code st Code Left Side h UV and Shunt Trips - C, D, F nd Code Voltage G Undervoltage Trip J V AC, 0 Hz P Left Side Only available on MCPs. Shunt Trip g Aux / Trip Contacts - I, N nd Code K D C H F A T N B VC M ZR ZQ ZJ ZW ZY ZZ ZB ZG ZE Right Side X Placeholder X Placeholder C N.O. + N.C. C N.O. + N.C. F N.O. + N.C. F N.O. + N.C. N N.O. (SC+OL) + N.C. (SC) N N.O. (SC+OL) + N.C. (SC) T N.O. + N.C. and N.O. + N.C. (SC+OL) T N.O. + N.C. and N.O. + N.C. (SC+OL) V AC, 0 Hz 0V AC, 0 Hz V AC, 0 Hz 0V AC, 0 Hz 0 0V AC, 0 Hz 0V AC, 0 Hz V AC, 0 Hz 0 00V AC, 0 Hz 0V AC, 0 Hz and V AC, 0 Hz 00V AC, 0 Hz V AC, 0 Hz and 00V AC, 0 Hz V DC V DC V DC V DC V DC 0V DC V DC V DC 0V DC - Publication A-CA00A-EN-P

30 Bulletin 0M Modifications 0M Factory Modifications (Open) Note: For modifications add (option code _) for desired features to cat. no. Available in North America only. st Code Top Front h UV and Shunt Trips - CMN nd Code G Undervoltage Trip KJ P Shunt Trip Cannot be combined with option "g". st Code G P Left Front Undervoltage Trip Left Front Shunt Trip h D A UV and Shunt Trips - H, J, L nd Code J D A B C J D B Voltage V AC, 0 Hz and V AC, 0 Hz 0V AC, 0 Hz and V AC, 0 Hz 0V AC, 0 Hz and 0 0V AC, 0 Hz UV Voltage V AC/DC V AC 0 0V AC 0 00V AC 00V AC Shunt Voltage 0V AC/DC 0V AC/DC 0 00V AC st Code G P st Code G P Left Front Undervoltage Trip Left Front Shunt Trip Left Front Undervoltage Trip Left Front Shunt Trip h UV and Shunt Trips - I h nd Code UV and Shunt Trips - N J D A B J D N B nd Code J D A B J D N B UV Voltage V AC V AC 0 0V AC 0 0V AC Shunt Voltage V AC/DC V AC and 0V DC 0 0V AC and V DC 00V AC and 0 0V DC UV Voltage V AC V AC 0 0V AC 0 0V AC Shunt Voltage V AC/DC 0V AC and V DC 0 0V AC and 0 0V DC 0 00V AC Publication A-CA00A-EN-P -

31 Bulletin 0M Specifications IEC Performance Data Cat. No. 0M-CE- A A A0 A B B B B0 B C C C0 C C C Rated Operational Current, I e [A] Magnetic Release Current [A] Switching of Standard Three-Phase Motors AC- 0/0V [kw] /V [kw] V [kw] V [kw] Back-Up Fuses gg, gl, only if I cc I cu 0/0V [A] /V [A] /0V [A] V [A] V [A] Ultimate Short Circuit Breaking Capacity I cu 0/0V [ka] /V [ka] /0V [ka] V [ka] V [ka] Rated Service Short Circuit Breaking Capacity I cs 0/0V [ka] /V [ka] /0V [ka] V [ka] V [ka] No back-up fuse required. - Publication A-CA00A-EN-P

32 Bulletin 0M Specifications IEC Performance Data, Continued Cat. No. 0M-DE- Cat. No. 0M-FE- B B0 B C C C0 C C C C C C0 C C C Rated Operational Current, I e [A] Magnetic Release Current [A] Switching of Standard Three-Phase Motors AC- 0/0V [kw] /V [kw] V [kw] V [kw] Back-Up Fuses gg, gl, only if I cc I cu 0/0V [A] 00/V [A] /0V [A] V [A] V [A] Ultimate Short Circuit Breaking Capacity I cu 0/0V [ka] /V [ka] /0V [ka] V [ka] V [ka] Rated Service Short Circuit Breaking Capacity I cs 0/0V [ka] /V [ka] /0V [ka] V [ka] V [ka] No back-up fuse required. Publication A-CA00A-EN-P -

33 Bulletin 0M Specifications IEC Performance Data, Continued 0-CMN- Cat. No Rated Operational Current, I e [A] 0 0 Magnetic Release Current [A] Switching of Standard Three-Phase Motors AC- 0/0V [kw]./. / /0 / 00/V [kw]./ / / / 00V [kw] /./ 0/0 / 0V [kw] / /0 / / Back-up fuses gg, gl,, only if I cc I cu 0/0V [A] 00/V [A] V [A] V [A] Ultimate short-circuit breaking capacity I cu 0/0V [ka] /V [ka] 0 00V [ka] V [ka] Rated service short-circuit breaking capacity I cs 0/0V [ka] /V [ka] V [ka] 0 0V [ka] No back-up fuse required. Power ratings: Preferred values according to IEC Publication A-CA00A-EN-P

34 Bulletin 0M Specifications IEC Performance Data, Continued Cat. No. 0M-CN- A A A0 A B B B Rated Operational Current, I e [A] Magnetic Release Current [A].... Switching of Standard Three-Phase Motors AC- 0/0V [kw] /V [kw] V [kw] V [kw] Back-Up Fuses gg, gl, only if I cc I cu 0/0V [A] 00/V [A] 0/0V [A] 00V [A] 0V [A] 0 Ultimate Short Circuit Breaking Capacity I cu 0/0V [ka] /V [ka] /0V [ka] V [ka] V [ka] Rated Service Short Circuit Breaking Capacity I cs 0/0V [ka] /V [ka] /0V [ka] V [ka] V [ka] No back-up fuse required. Publication A-CA00A-EN-P -

35 Bulletin 0M Specifications IEC Performance Data, Continued Cat. No. 0M-DN- Cat. No. 0M-FN- B B0 B C C C C C C C Rated Operational Current, I e [A]..0. Magnetic Release Current [A] 0 0 Switching of Standard Three-Phase Motors AC- 0/0V [kw] /V [kw] V [kw] V [kw] Back-Up Fuses gg, gl, only if I cc I cu 0/0V [A] 0 00/V [A] 0 0 0/0V [A] V [A] V [A] Ultimate Short Circuit Breaking Capacity I cu 0/0V [ka] /V [ka] /0V [ka] V [ka] V [ka] Rated Service Short Circuit Breaking Capacity I cs 0/0V [ka] /V [ka] /0V [ka] V [ka] V [ka] No back-up fuse required. - Publication A-CA00A-EN-P

36 Bulletin 0M Specifications IEC Performance Data, Continued Cat. No. 0M-CT- A A A0 A B B B B0 B C C Rated Operational Current, I e [A] Magnetic Release Current [A] Switching of Standard Three-Phase Motors AC- 0/0V [kw] /V [kw] V [kw] V [kw] Back-Up Fuses gg, gl, only if I cc I cu 0/0V [A] 00/V [A] 0 0/0V [A] 0 00V [A] 0 0 0V [A] Ultimate Short Circuit Breaking Capacity I cu 0/0V [ka] /V [ka] /0V [ka] V [ka] V [ka] Rated Service Short Circuit Breaking Capacity I cs 0/0V [ka] /V [ka] /0V [ka] V [ka] V [ka] No back-up fuse required. Publication A-CA00A-EN-P -

37 Bulletin 0M Specifications IEC Performance Data, Continued Cat. No. 0M-DT- Cat. No. 0M-FT- C C0 C C Rated Operational Current, I e [A] 0 Magnetic Release Current [A] 0 Switching of Standard Three-Phase Motors AC- 0/0V [kw] /V [kw]. 00V [kw] 0 0V [kw] 0 Back-up fuses gg, gl,, only if I cc I cu 0/0V [A] 00/V [A] /0V [A] V [A] V [A] 0 0 Ultimate short-circuit breaking capacity I cu 0/0V [ka] /V [ka] 0 0/0V [ka] 0 00V [ka] V [ka] Rated service short-circuit breaking capacity I cs I cs 0/0V [ka] /V [ka] 0 0 0/0V [ka] V [ka] 0 0 0V [ka] No back-up fuse required. Consult your local Rockwell Automation sales office or Allen-Bradley distributor. - Publication A-CA00A-EN-P

38 Bulletin 0M Specifications General Data Rated Insulation Voltage U i Cat. No. 0M-C 0M-D 0M-F 0-CMN IEC, SEV, VDE 00 [V] 0 0 UL, CSA [V] Rated Impulse Withstand Voltage U imp Pollution degree Main circuits U imp /Overvoltage Category kv/iii kv/iii Auxiliary circuits U imp /Overvoltage Category kv/iii kv/iii Rated Frequency [Hz] 0/0 0 0 Utilization Category IEC 0- (Circuit breaker) A A IEC 0-- (Motor starter) AC- AC- Life Span Mechanical [operations] Electrical (I e max.) [operations] (up to A) 000 (up to 0 A) Switching Frequency [operations/h] max. max. 0 Ambient Temperature Storage [ C] Operation [ C] - +0 Climatic resistance Moisture change climate (000--0) C / % relative humidity and 0 C / % relative humidity, cycles Dry heat (00--) 0 C, relative humidity <0 %, days Moisture heat (00--) 0 C, relative humidity %, days Site Altitude [m] to 000 N.N. Protection Class IPX, when wired Resistance to Shock, Transport (00--) 0 g, ms, all axes 0, ms Resistance to Vibration, Opertion (00--) g Rated Thermal Current I th up to 0 C ambient temperature [A] up to 0 C ambient temperature [A] Rated Supply Current I e [A] Dependence on Temperature 0 C [A] no reduction 0 C [A] no reduction 0 C [A] no reduction 0 C [A] % current reduction of the upper rated current I e Overload Protection Characteristics IEC 0-- Motor protection (except Cat. Nos. 0M-CN, 0M-DN, 0M-FN) IEC 0 Ambient Temperature Compensation [ C] Phase-loss Protection Differential release Trip class (except Cat. Nos. 0M-CN, 0M-DN, 0M-FN) fixed setting Magnetic Release Release current (+/-0 %) fixed setting x I e max. (for 0M-CE, 0M-DE, 0M-FE, 0M-CN, 0M-DN, 0M-FN) x I e max. (for 0M-CT, 0M-DT, 0M-FT) I e max. = maximum values of setting ranges fixed setting x I e max. Total Power loss P v Circuit Breaker at rated load operating temperature [W].. Main Disconnect Switch Application Yes, with accessories For utilization outside North America, assemblies (of products) shall comply to the IEC - requirements Application Conditions 0M manual motor starters are intended for use in closed areas without hazardous operating conditions such as dust or explosive or corrosive gases. Enclosures of appropriate manner need to be in place to protect devices in such environments. Publication A-CA00A-EN-P -

39 Bulletin 0M Specifications General Data, Continued Conformity to Standards Cat. No. 0M-C 0M-D 0M-F 0-CMN IEC 0-; -; --; EN 0-; -; --; UL 0; CSA., No. IEC 0-; -; EN 0-; -; UL 0; CSA., No. Approvals CE, UL, CSA CE, UL, CSA Terminal Parts Type of terminals Screwdriver Pozidriv No. /Blade No. Pozidriv No. /Blade No.. conductor. conductor. conductor. conductor. conductor. conductor. conductor. conductor [mm ]/[AWG] [mm ]/[AWG] [mm ]/[AWG] [mm ]/[AWG] [mm ]/[AWG] [mm ]/[AWG] [mm ]/[AWG] [mm ]/[AWG] /No. /No. /No. /No.. /No.. /No. /No. /No.. /No.. /No.. /No.. /No. /No. /No.. /No.. /No... 0 / 0 / Tightening torque [Nm]/[lb in]././ 0 / 0 Screwless Cat. No. 0M-RC Terminal Parts Type of terminals Screwdriver. conductor. conductor. conductor. conductor. conductor. conductor Accessories for Bulletin 0M Motor Protection Circuit Breakers Rated Thermal Current I th at 0 C ambient temperature at 0 C ambient temperature Contact Class Coordination According to NEMA (UL/CSA Standards) [A] [A] AC DC Auxiliary Contact Blocks for Front Mounting Cat. No. 0M-C-AFA, 0M-C-AFAR B 00 Q 00 Auxiliary Contact Blocks for Right-Side Mounting Cat. No. 0M-C-ASA, 0M-C-ASAR Back-Up Fuses gg, gl [A] Rated Supply Current [V] AC- [A]. 0. DC- [V] [A] Terminal Parts Type of terminals Screwdriver Pozidriv No. /Blade No.. conductor. conductor. conductor. conductor. conductor. conductor [mm ]/[AWG] [mm ]/[AWG] [mm ]/[AWG] [mm ]/[AWG] [mm ]/[AWG] [mm ]/[AWG] [mm]/[awg] [mm]/[awg] [mm]/[awg] [mm]/[awg] [mm]/[awg] [mm]/[awg] / 0../ 0../No. 0../No. /No. /No. 0../ 0../ 0../ 0../ 0../ 0../ B 00 Q / 0../ 0../ 0../ 0../ 0../ Tightening torque [N m]/[lb in]../.../.. - Publication A-CA00A-EN-P

2-2. Bulletin 140M Motor Protection Circuit Breakers. Product Overview. Table of Contents. Standards Compliance. Certifications. General Information

2-2. Bulletin 140M Motor Protection Circuit Breakers. Product Overview. Table of Contents. Standards Compliance. Certifications. General Information Bulletin 0M Motor Protection Circuit Breakers Product Overview Bulletin 0M Motor Protection Circuit Breakers Current Rane 0. 0 A UL Listed for Motor Loads Short Circuit Protection Overload Protection Visible

More information

Cat. No. 140M-F M-D8E-B

Cat. No. 140M-F M-D8E-B Bulletin 0M Motor Protection Circuit Breakers Product Selection Motor Protection Circuit Breakers Short Circuit Protection Standard Magnetic Trip ( x I e ) Motor Overload Protection Trip Class Rated Operational

More information

General characteristics, Products

General characteristics, Products The Feature Packed line of Manual Motor Protectors Eaton s new XT family of Manual Motor Protectors (MMPs) features a pushbutton or rotary ON/OFF manual disconnect, Class adjustable bimetallic overload

More information

TeSys circuit-breakers

TeSys circuit-breakers Presentation Thermal-magnetic motor circuit-breakers types GV2, GV and GV7 GV2-ME, GV2-P, GV-ME and GV7-R motor circuit-breakers are -pole thermal-magnetic circuit-breakers specifically designed for the

More information

5SJ4...-.HG Circuit Breakers to IEC and UL 489

5SJ4...-.HG Circuit Breakers to IEC and UL 489 Siemens AG 009 5SJ...-.HG Circuit Breakers to IEC and UL 89 BETA Low-Voltage Circuit Protection Compliance with industry standards is a must in today's manufacturing environment. Worldwide acceptance is

More information

UL 1077 DIN Rail Supplementary Protectors

UL 1077 DIN Rail Supplementary Protectors UL 0 DIN Rail Supplementary Protectors Product Overview UL 0 DIN Rail Supplementary Protectors PRODUCT OVERVIEW Product Overview Standard Features WMZS breaker terminals provide finger and back-of-hand

More information

BETA Protecting Miniature Circuit Breakers

BETA Protecting Miniature Circuit Breakers Siemens AG 00 / Product overview / High-capacity range 000 A 0000 A 0000 A, high current 0000 A, universal current 000 A ka /0 Comfort range with plug-in terminal / Compact range +N in MW / Additional

More information

5SP and 5SY Supplementary Protection UL 1077

5SP and 5SY Supplementary Protection UL 1077 Product Guide 5SP and 5SY Supplementary Protection UL 077 for North merican and International applications usa.siemens.com/5sy Table of contents Certifications, standards, features and description Characteristic

More information

Sealing possibility Electrical endurance (ops) Mechanical endurance (ops) Overvoltage category Standards

Sealing possibility Electrical endurance (ops) Mechanical endurance (ops) Overvoltage category Standards Miniature circuit breaker ETIMAT 7,7 0.5 Rated voltage Rated current Rated frequency Rated short-circuit capacity Energy limiting class characteristic Build-in width Mounting on the rail 0/00 V AC, max.

More information

Thermal-Magnetic Circuit Breaker 2210-T2...

Thermal-Magnetic Circuit Breaker 2210-T2... Thermal-Magnetic Circuit Breaker 0-T... Description One, two and three pole thermal-magnetic circuit breakers with trip-free mechanism and toggle actuation (S-type TM CBE to EN 6094/IEC 94). Featuring

More information

Siemens AG Miniature Circuit Breakers. Totally Integrated Power SENTRON. Configuration. Edition 10/2014. Manual. siemens.

Siemens AG Miniature Circuit Breakers. Totally Integrated Power SENTRON. Configuration. Edition 10/2014. Manual. siemens. Siemens AG 05 Totally Integrated Power SENTRON Configuration Manual Edition 0/0 siemens.com/lowvoltage Siemens AG 05 Siemens AG 05 Introduction 5SL miniature circuit breakers 5SY and 5SP miniature circuit

More information

08/072 PKZ2 Motor-Protective Circuit-Breakers Tripping Characteristics

08/072 PKZ2 Motor-Protective Circuit-Breakers Tripping Characteristics 0/07 PKZ Tripping Characteristics Moeller HPL0-00/00 S-PKZ high-capacity contact module, SEA-PKZ contact module Normal switching duty AC-/00V kw A Rated output of three-phase motors 0...0 Hz. 7..... 0.7

More information

MCB NB1-63H Miniature Circuit Breaker

MCB NB1-63H Miniature Circuit Breaker NB-H Miniature Circuit Breaker. General. Function protection of circuits against short-circuit currents, protection of circuits against overload currents, switch, isolation, NB-H circuit-breakers are used

More information

Thermal-Magnetic Circuit Breaker 2210-S2..

Thermal-Magnetic Circuit Breaker 2210-S2.. Thermal-Magnetic Circuit Breaker -S.. Description One, two and three pole thermal-magnetic circuit breakers with trip-free mechanism and toggle actuation (S-type TM CBE to EN 60934/IEC 934). Designed for

More information

440V 500V V / / /2 12.

440V 500V V / / /2 12. -26 Manual Motor Protectors March 0 B-Frame D-Frame Table -6. XTPR Rotary Manual Motor Protectors with Screw Terminals Global Ratings and North American Ratings Type and Type 2 Coordination Motor Protective

More information

X T O B P 1 6 B C 1 S

X T O B P 1 6 B C 1 S 9 Overload Relays XTOB, XTOT May 07 Contents Description Page Overload Relays XTOB, XTOT Selection................ 9 Product Selection.......... 95 Accessories............... 9 Technical Data and Specifications............

More information

Thermal-Magnetic Circuit Breaker 2210-S2..

Thermal-Magnetic Circuit Breaker 2210-S2.. Thermal-Magnetic Circuit Breaker -S.. Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 60934/IEC 934). Designed for

More information

Overload Relays. SIRIUS 3RU1 Thermal Overload Relays. 3RU11 for standard applications. 5/46 Siemens LV 1 AO 2011

Overload Relays. SIRIUS 3RU1 Thermal Overload Relays. 3RU11 for standard applications. 5/46 Siemens LV 1 AO 2011 SIRIUS 3RU1 Thermal Overview 1 2 7 3 4 6 "Increased safety" type of EEx e according to ATEX directive 94/9/EC The 3RU11 thermal overload relays are suitable for the overload of explosion-proof motors with

More information

Thermal-Magnetic Circuit Breaker 2210-S2...

Thermal-Magnetic Circuit Breaker 2210-S2... Thermal-Magnetic Circuit Breaker 0-S... Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 60934/IEC 934). Designed

More information

Thermal-Magnetic Circuit Breaker 2210-S2...

Thermal-Magnetic Circuit Breaker 2210-S2... Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 6094/IEC 94). Designed for panel or plug-in mounting. Available

More information

Thermal-Magnetic Circuit Breaker 2210-S2..

Thermal-Magnetic Circuit Breaker 2210-S2.. Thermal-Magnetic Circuit Breaker -S.. Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 6094/IEC 94). Designed for

More information

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-T...

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-T... Magnetic and Hydraulic-Magnetic Circuit Breaker 830-T... Description ngle, two and three pole magnetic and hydraulic-magnetic circuit breakers with trip-free mechanism and toggle actuation. A choice of

More information

C120N circuit-breakers B, C and D curves EN 60898/EN 61009: IEC : 10 ka

C120N circuit-breakers B, C and D curves EN 60898/EN 61009: IEC : 10 ka C0N circuit-breakers B, C and D curves EN 09/EN 009: 0000 - IEC 097-: 0 ka function # protection of cables against overloads and short-circuits in final distribution # manual control and isolation # earth

More information

FAZ tripping characteristics at 30 C: B, C, D to IEC/EN FAZ tripping characteristics at 30 C: R to IEC/EN

FAZ tripping characteristics at 30 C: B, C, D to IEC/EN FAZ tripping characteristics at 30 C: R to IEC/EN FAZ, AZ High-Capacity Tripping Characteristics Moeller HPL011-001/00 1/07 FAZ tripping characteristics at 0 C: B, C, D to IEC/EN 0 9 FAZ tripping characteristics at 0 C: R to IEC/EN 0 97 t [s] 700 00 100

More information

BETA Protecting. Low-Voltage Fuse Systems. LV HRC fuse links. 3/36 Siemens ET B1 2008

BETA Protecting. Low-Voltage Fuse Systems. LV HRC fuse links. 3/36 Siemens ET B1 2008 LV HRC fuse links Overview LV HRC fuses are used for installation systems in non-residential, commercial and industrial buildings as well as in switchboards of power supply companies. They therefore protect

More information

TeSys contactors. TeSys D contactors. 690 V on a and c

TeSys contactors. TeSys D contactors. 690 V on a and c Selection guide TeSys D contactors Applications All types of control system Rated operational current le max AC- (Ue y 0 V) A A A A A A le AC- (q y 0 C) 0/ A / A /0 A 0 A Rated operational voltage 0 V

More information

Varius SUMMARY OF MODELS OF HRC FUSE-LINKS

Varius SUMMARY OF MODELS OF HRC FUSE-LINKS SUMMARY OF MODELS OF HRC FUSE-LINKS Type PNA000 PHNA000 PNA00 PHNA00 Rated current I n up to A up to 0 A up to A up to 0 A Rated voltage U n AC 00 V, 00 V 90 V 00 V 90 V DC 0 V 0 V 0 V 0 V Fuse-link size

More information

3VT4 Molded Case Circuit Breakers up to 1000 A

3VT4 Molded Case Circuit Breakers up to 1000 A VT4 Molded Case Circuit Breakers up to 00 A Catalog Technical nformation VT4 Molded Case Circuit Breakers up to 00 A General data / - Overview Circuit breakers Switch disconnectors / - Selection and ordering

More information

Issued August DATA SHEET. 3VT3 MCCB up to 630 A

Issued August DATA SHEET. 3VT3 MCCB up to 630 A ssued August 9 DATA SHEET VT MCCB up to 6 A Based on Siemens Catalog V 6 8 Circuit breakers Switch disconnectors Technical specifications Specifications Type VT 76-AA6/6/56-AA, VT 76-AA6/6/56-AA Circuit

More information

Issued August DATA SHEET. 3VT5 MCCB up to 1600 A

Issued August DATA SHEET. 3VT5 MCCB up to 1600 A ssued August 9 DATA SHEET VT5 MCCB up to 0 A Based on Siemens Catalog V 8 Standard circuit breakers Releases Technical specifications Specifications VT5 circuit breakers Switch disconnectors Type Standards

More information

Non-Fused. Series DS2 IEC Non-Fused 12 Disconnect Switches. Accessories 15. Specifications 16. Dimensions 17. See Enclosed Disconnects 21

Non-Fused. Series DS2 IEC Non-Fused 12 Disconnect Switches. Accessories 15. Specifications 16. Dimensions 17. See Enclosed Disconnects 21 s e r i e s c3controls offers the most rugged, dependable Disconnect Switches that money can buy. From Panel/Base Mount to Door Mount with switch ratings from 16A - 125A, we ve got what you need. And,

More information

ATyS Automatic and remotely operated transfer switches from 125 to 3200 A

ATyS Automatic and remotely operated transfer switches from 125 to 3200 A atys-p_001_b atys_d_001_a_1_cat ATyS p I-0-II 4P ATyS d I-0-II 4P Function The ATyS are three-phase motorised transfer switches with positive break indication. They enable the on load transfer of two three-phase

More information

TeSys enclosed starters 2

TeSys enclosed starters 2 Characteristics, references TeSys enclosed starters D..L. starters for motor control 0. to. kw with -phase thermal overload relay with protected phases Characteristics () Conforming to standards IEC 0--,

More information

90 MCB MODULAR CIRCUIT BREAKERS FOR CIRCUIT PROTECTION

90 MCB MODULAR CIRCUIT BREAKERS FOR CIRCUIT PROTECTION MCB - MTC - MT - MTHP Technical data TYPE MTC MT MTC45 MTC60 MTC100 MT 45 MT 60 Rated current (In) (A) 2-32 6-32 6-32 6-40 1-63 Utilization category A A A A A Rated operational voltage (Ue) (V) 230/400-240/415

More information

H i g h A m p e r a g e 2 5 t o A M P. T y p e I & I I I V e h i c l e P r o t e c t i o n. I P 6 7 W a t e r p r o o f

H i g h A m p e r a g e 2 5 t o A M P. T y p e I & I I I V e h i c l e P r o t e c t i o n. I P 6 7 W a t e r p r o o f H i g h A m p e r a g e 2 5 t o 3 0 0 A M P T y p e I & I I I V e h i c l e P r o t e c t i o n I P 6 7 W a t e r p r o o f I g n i t i o n - P r o t e c t e d S A E & A B Y C C o m p l i a n t L E D T

More information

C60N circuit breakers0 B, C and D curves IEC 60898: 6000 A, IEC : 10 ka

C60N circuit breakers0 B, C and D curves IEC 60898: 6000 A, IEC : 10 ka C0N circuit breakers0 B, C and s IEC 0898: 000 A, IEC 097-: 0 ka Function b The circuit-breakers combine the following functions: v protection of circuits against short-circuit currents v protection of

More information

TeSys protection components Thermal-magnetic motor circuit-breakers GV2 ME and GV2 P

TeSys protection components Thermal-magnetic motor circuit-breakers GV2 ME and GV2 P Dimensions GV ME and GV P Dimensions GV ME GV AX GV AD, AM, AN, AU, AS, AX, X Block GV AD, AM, AN Block GV AU, AS, AX GV AE b, X b GV MEpp GV MEpp () Maximum X Electrical clearance 0 mm for Ue y 0 V,,,

More information

Masterpact. Installation recommendations

Masterpact. Installation recommendations 90 Installation recommendations Presentation Functions and characteristics 9 Dimensions and connection 5 Electrical diagrams 8 Operating conditions 92 Installation in switchboard 9 Door interlock catch

More information

To order, specify : Types Protection functions Current surge Asymmetry and loss of phase. Operating principle

To order, specify : Types Protection functions Current surge Asymmetry and loss of phase. Operating principle otor protection relays - T - FWIT Since % of -phase motor failures are due to load problems or loss of phase, the CROUZET range of motor protection relays is indispensable! models give motor protection

More information

Non-Contact Safety Systems CMS

Non-Contact Safety Systems CMS Selection table for non-contact safety system // Evaluation units Connection Desi Read head contact assembly Assured switch-on distance S ao [mm] Assured switch-on distance S ar [mm] Number of outputs

More information

GPS1B. Characteristics. Technical performances

GPS1B. Characteristics. Technical performances Thermal and magnetic protection PS Motor protection devices Standards/pprovals 097, 0972, 097 N V 00T 0//2 UL/S UL/cULus Shipping approvals: RN ureau Lloyd s Register Veritas ermanischer Lloyd haracteristics

More information

8 Installation Equipment

8 Installation Equipment 8 Installation Equipment Plugs and Sockets CES System Series 8, 88, 8, 881 Te plugs and sockets in te CES system comply wit CEE publication 1 and European standards EN 0 01. Te small 1 A socket as switcing

More information

90 MCB range Modular circuit breakers for circuit protection

90 MCB range Modular circuit breakers for circuit protection MCB - MTC - MT - MTHP Technical data TYPE MTC MT MTC45 MTC60 MTC100 MT 45 MT 60 Rated current (In) (A) 2-32 6-32 6-32 6-40 1-63 Utilization category A A A A A Rated operational voltage (Ue) (V) 230 / 400

More information

EX-CONTROL AND DISTRIBUTION SYSTEMS

EX-CONTROL AND DISTRIBUTION SYSTEMS EX-CONTROL AND DISTRIBUTION SYSTEMS Cooper Crouse-Hinds 00 - all rights reserved EX-DISTRIBUTION IN PLASTIC DESIGN. EX-DISTRIBUTION IN STAINLESS STEEL EX-D BUILT-IN COMPONENTS.. 9 EX-E EMPTY ENCLOSURES

More information

BASE. Rotary limit switch. OptiOnS. FEAtuRES. CERtiFiCAtiOnS

BASE. Rotary limit switch. OptiOnS. FEAtuRES. CERtiFiCAtiOnS Rotary limit switch BASE Rotary limit switch used to control and measure the movement of industrial machines. Its compact size make it suitable for use in narrow spaces. FEAtuRES It consists of a gear

More information

SIRCOVER Manual transfer switches from 125 to 3200 A

SIRCOVER Manual transfer switches from 125 to 3200 A Manual transfer switches svr_149_a 3200 A Function are manual multipolar transfer switches with positive break indication. The family includes two ranges: AC for dead time switching (I-0-II), for overlapping

More information

Request Ensure that this Instruction Manual is delivered to the end users and the maintenance manager.

Request Ensure that this Instruction Manual is delivered to the end users and the maintenance manager. Request Ensure that this Instruction Manual is delivered to the end users and the maintenance manager. 1 -A - Introduction - Thank for your purchasing MITSUBISHI ELECTRIC MELPRO TM D Series Digital Protection

More information

7S SERIES. Relay module with forcibly guided contacts 6 A 7S S /0310 7S

7S SERIES. Relay module with forcibly guided contacts 6 A 7S S /0310 7S Relay module with forcibly guided contacts.12 with 2 pole (1NO + 1 N).14 with 4 pole (2 NO + 2 N and 3 NO + 1 N).16 with 6 pole (4 NO + 2 N) For safety applications, with class A forcibly guided contact

More information

Impedance relay and protection assemblies

Impedance relay and protection assemblies RXZK 21H, 22H, 23H 509 006-BEN Page 1 Issued June 1999 Changed since July 1998 Data subject to change without notice (SE970175) (SE970184) Features Micro-processor based impedance relay with R and X settings

More information

400 Volts, 50HZ 480 Volts, 60HZ 600 Volts, 60HZ TECHNICAL REFERENCE MANUAL

400 Volts, 50HZ 480 Volts, 60HZ 600 Volts, 60HZ TECHNICAL REFERENCE MANUAL 400 Volts, 50HZ 480 Volts, 60HZ 600 Volts, 60HZ TECHNICAL REFERENCE MANUAL FORM: MAP-TRM-E REL. July 2013 REV. 015 2013 MTE Corporation IMPORTANT USER INFORMATION NOTICE The MTE Corporation Matrix AP Harmonic

More information

PHOENIX CONTACT - 04/2016. Features

PHOENIX CONTACT - 04/2016. Features Signal conditioner Data sheet 100238_de_06 1 Description PHOENIX CONTACT - 04/2016 Features The MCR-C-UI-UI(-450)-DCI(-NC) 3-way isolation amplifier is used to electrically isolate and convert analog signals.

More information

Miniature Circuit Breaker

Miniature Circuit Breaker Miniature Circuit Breaker SG-DPN I E C / E N 0 8 9 8-5 0 0 SG-DPN Applications Approval / Marking Function and Feature Integrate with switch phase and neutral in one module Protection against both overload

More information

Miniatur Circuite Breakers (MCB)

Miniatur Circuite Breakers (MCB) Redline Miniatur Circuite Breakers (MCB) Technical data MCB s Series Standards Tripping characteristics Nominal current Calibration temperature Number of poles (#mod) Neutral pole protected Nominal voltage

More information

Single Phase Motors Technical Datasheets

Single Phase Motors Technical Datasheets Single Phase Motors Technical Datasheets EN A dynamic, strong and ambitious Group: Orange1 Holding is an international renown Group, one of the most important European manufacturers of single-phase and

More information

Semiconductor (AC) fuses

Semiconductor (AC) fuses gr 690 VAC sizes 000 to (full range) Ferraz Shawmut PROTISTOR NH grb 690 VAC fuselinks provide maximum flexibility in equipment design and ultimate protection for today s power conversion equipment. This

More information

THE DIMENSIONING OF ELECTRICAL CONDUCTORS FOR USE IN "PANEL BOARDS" ADDRESSED TO HAZARDOUS AREAS - PART THREE

THE DIMENSIONING OF ELECTRICAL CONDUCTORS FOR USE IN PANEL BOARDS ADDRESSED TO HAZARDOUS AREAS - PART THREE July 04 THE DIMENSIONING OF ELECTRICAL CONDUCTORS FOR USE IN "PANEL BOARDS" ADDRESSED TO HAZARDOUS AREAS - PART THREE In this third part. we want to speak about how important is the correct sizing of the

More information

Installation Contactors ISU-xxx ISM-xxx

Installation Contactors ISU-xxx ISM-xxx Installation Contactors ISU-xxx ISM-xxx Installation contactors are used in building technology switching cabinets of apartment blocks, office buildings, restaurants and hotels, shopping centres and hospitals

More information

LD-LP-LL-LC Rope Safety Switches with reset for emergency stop

LD-LP-LL-LC Rope Safety Switches with reset for emergency stop TECHNICA DATASHEET D-P--C Rope Safety Switches with reset for emergency stop Metal or polymer housing, from one or three conduit entries Protection degree IP6 In conformity with EN ISO 13850 contact blocks

More information

Universal limit switches

Universal limit switches SWITCHES.CROUZET.COM 1 LIMIT SWITCHES 0/016 Universal limit switches 8384 standard 8384 with positive break operation Conformity to standards IEC / EN 60947--1, including Annex K for version with positive

More information

MINIATURE MICROSWITCHES - PREMIUM

MINIATURE MICROSWITCHES - PREMIUM 0/08 MINIATURE MICROSWITCHES - PREMIUM V - 86 High precision flexible leaf snap-action mechanism Operation without balance-point, even at extremely slow actuating speed Broad range of operating forces

More information

6 INCH W X 5-3/4 INCH D X 8-3/8 INCH H

6 INCH W X 5-3/4 INCH D X 8-3/8 INCH H 0 South Street -, TX Nacogdoches Phone: -- Fax: -0- S0N0AN.KVA PH 0/V /V Buck Boost Transformer Eaton Corp Catalog Number S0N0AN Manufacturer Eaton Corp Description Buck Boost Transformer, Power Rating

More information

Moulded Case Circuit Breakers. Breaking capacity code: S:standard H:Higher type/r:current limiting type

Moulded Case Circuit Breakers. Breaking capacity code: S:standard H:Higher type/r:current limiting type TPact Moulded Case Circuit Breakers TPact Moulded Case Circuit Breaker. General Certificates: KEMA,CB; Electric ratings: AC0/0Hz, AC0V~90V DC0V~00V, A~0A; Standard: IEC/EN 097.. Type Designation TPact...

More information

MINIATURE MICROSWITCHES - PREMIUM

MINIATURE MICROSWITCHES - PREMIUM 0/06 MINIATURE MICROSWITCHES - PREMIUM V - 86 High precision flexible leaf snap-action mechanism Operation without balance-point, even at extremely slow actuating speed Broad range of operating forces

More information

VX25 Enclosure System. Technical documentation PE conductor connection, current carrying capacity

VX25 Enclosure System. Technical documentation PE conductor connection, current carrying capacity VX Enclosure System Technical documentation PE conductor connection, current carrying capacity Enclosure system VX Contents Contents. General remarks. Introduction. Notes on the design of the earthing

More information

Amphenol C 091 A/B/D. Circular Connectors. Amphenol-Tuchel Electronics GmbH

Amphenol C 091 A/B/D. Circular Connectors. Amphenol-Tuchel Electronics GmbH Amphenol C 091 A/B/D Circular Connectors Amphenol-Tuchel Electronics GmbH General information These connectors are designed and produced in conformity with the low-voltage directive (/3/EWG) respectively

More information

Amphenol. Amphenol-Tuchel Electronics GmbH. Circular Connectors C 091 A/B/D Series

Amphenol. Amphenol-Tuchel Electronics GmbH. Circular Connectors C 091 A/B/D Series Amphenol Amphenol-Tuchel Electronics GmbH Circular Connectors C 09 A/B/D Series The Company Amphenol-Tuchel Electronics GmbH is a member of the USA based Amphenol Corporation. With our own global presence

More information

Table of Contents Pin-Configuration Selection Guide for HDE, HDS, & EFP

Table of Contents Pin-Configuration Selection Guide for HDE, HDS, & EFP Table of Contents -Configuration Selection Guide for HDE, HDS, & EFP Service Voltage Rating... Electrical Service Ratings... Ampacity Ratings by Contact... Electrical Service Ratings Explained... Operating

More information

Request Ensure that this Instruction Manual is delivered to the end users and the maintenance manager.

Request Ensure that this Instruction Manual is delivered to the end users and the maintenance manager. Request Ensure that this Instruction Manual is delivered to the end users and the maintenance manager. 1 -C - Safety section - This Safety section should be read before starting any work on the relay.

More information

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Current Transducer HO-NP series I P N = 4, 6, 12, 15 A Ref: HO 4-NP, HO 6-NP, HO 12-NP, HO 15-NP For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary

More information

Performance. Standards. Technical data

Performance. Standards. Technical data ilos Loadbreak disconnectors for INrail and wall mounting ilos up to ilos 2 up to los up to Order codes pplications pprovals / Marking ddon devices Performance INrail type and wall mounting type Main disconnector,

More information

Varius SUMMARY OF MODELS OF HRC FUSE-LINKS. Type PVA10 / PV10 PV14 PV22 Rated current I n up to 32 A up to 63 A up to 125 A Rated voltage U n

Varius SUMMARY OF MODELS OF HRC FUSE-LINKS. Type PVA10 / PV10 PV14 PV22 Rated current I n up to 32 A up to 63 A up to 125 A Rated voltage U n Varius SUMMARY OF MODELS OF HRC FUSE-LINKS Type A / Rated current I n up to A up to up to A Rated voltage U n AC V, V V, V, 9 V V, V, 9 V DC V V V Fuse-link size x8 x x8 Utilization category of the fuse-link

More information

Semiconductor (AC) fuses

Semiconductor (AC) fuses PSC gr sizes 7x - 690 VAC Main characteristics 6,9 grb 71 PA 200 6,9 grb 73 TTF 1000 + MS7V1-5 UR Ferraz Shawmut PSC-gRB 690 VAC fuse-links provide maximum flexibility in equipment design and ultimate

More information

Time - timing relays 1 Industrial relays, solid state output, width 22.5 mm

Time - timing relays 1 Industrial relays, solid state output, width 22.5 mm haracteristics Zelio ime - timing relays Industrial relays, solid state output, width. mm Presentation 08 he E9 range of relays is designed for simple, repetitive applications with short and intensive

More information

MR medium rating busbar

MR medium rating busbar technical information General features MR is fully compliant with S EN 0-, specifically, the rated current of the Zucchini busbar trunking systems is always rated at the average ambient temperature of

More information

ct m ive p 5/EC Thermal cut-outs

ct m ive p 5/EC Thermal cut-outs RoHS Compliant Directive //EC Marking of switches type: AM, AF, AB,, AA. AM0. 0. 0 0/0 -. 0 Strip length Second conductor length First conductor length Type of thermal cut-out Rated switching temperature

More information

ED 701 General Industry Pressure Transmitter

ED 701 General Industry Pressure Transmitter ED 701 General Industry Pressure Transmitter Standard industrial process connections Complete range of electrical connections 4... 20 ma and Voltage outputs Accuracy: 0.1%, 0.2% and 0.4% FS Quick response

More information

F F FAULT CURRENT Prospective. 1. Introduction. 2. Types of fault conditions

F F FAULT CURRENT Prospective. 1. Introduction. 2. Types of fault conditions FAULT CURRENT F F13-13 FAULT CURRENT - Contents 1. Introduction 2. Types of fault conditions 3 fault current must be determined 3.1 Purposes for which of prospective fault current magnitudes are used 3.2

More information

Technical catalogue SmiSSline electrical protective devices in a system

Technical catalogue SmiSSline electrical protective devices in a system Technical catalogue SmiSSline electrical protective devices in a system SmiSSline The original Shaping the future SmiSSline protection devices are simply snapped into a plug-in socket system. The arduous

More information

32 Input AC Block I/O Module

32 Input AC Block I/O Module Input AC Module Cat. No. 79-A0 Series B Installation Mount the block I/O module in a vertical (recommended) or horizontal position. Allow sufficient room around the block for cooling air to flow through

More information

Analogue Meters CQ2x07 series

Analogue Meters CQ2x07 series Analogue Meters CQ2x07 series Analogue Power Meters Active, reactive, apparent power meters and Power factor meters with exchangeable scales EQ0207/2207/0107/2107 & YQ0207/2207/0107/2107 o Measurement

More information

Switches in conformity with ATEX directive

Switches in conformity with ATEX directive E Switches in conformity with ATEX directive page / General Catalog 09-0 Technical concepts page /9 A B Position switches FD series page / Category Zone Approvals Article code extension G M ATEX category

More information

Blocks and Holders POWR-BLOKS. Connectors. Ampere Ratings. Ordering Information. Applications. Specifications. Distribution/Splicer Blocks and Covers

Blocks and Holders POWR-BLOKS. Connectors. Ampere Ratings. Ordering Information. Applications. Specifications. Distribution/Splicer Blocks and Covers Connectors Box lug connectors are designed for use with a single, solid or class B or C stranded conductor. Use of more than one conductor per connector opening or use of extra-flexible, fine stranded

More information

ISOCON-3 MAINS POWERED ISOLATING SIGNAL CONVERTER

ISOCON-3 MAINS POWERED ISOLATING SIGNAL CONVERTER ISOCON-3 MAINS POWERED ISOLATING SIGNAL CONVERTER CAUTION: This equipment is designed for connection to mains voltages and must be used in accordance with this guide. If it is not, the safety protection

More information

ISOCON-6. 24V AC or DC POWERED ISOLATING SIGNAL CONVERTER

ISOCON-6. 24V AC or DC POWERED ISOLATING SIGNAL CONVERTER ISOCON-6 24V AC or DC POWERED ISOLATING SIGNAL CONVERTER Whilst every effort has been taken to ensure the accuracy of this document, we accept no responsibility for damage, injury, loss or expense resulting

More information

Performance. Standards. Technical data

Performance. Standards. Technical data ilos Loadbreak disconnectors for wall mounting ilos H up to 5 ilos 3 up to ilos 4 up to Order codes pplications pprovals / Marking ilos H34 ilos H ddon devices Performance Wall mounting Main disconnector,

More information

Semiconductor (AC) fuses

Semiconductor (AC) fuses Main characteristics 6,9 grb 7 PA 6,9 grb 73 TTF 000 + MS7V-5 UR Ferraz Shawmut PSC-gRB 690 VAC fuse-links provide maximum flexibility in equipment design and ultimate protection for today s power conversion

More information

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Current Transducer HO-NSM series I PN = 8, 15, 25 A Ref: HO 8-NSM, HO 15-NSM, HO 25-NSM For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the

More information

16 Input AC Block I/O Module

16 Input AC Block I/O Module 6 Input AC Module Cat. No. 79-6A0 Series B Installation Mount the block I/O module in a vertical (recommended) or horizontal position. Allow sufficient room around the block for cooling air flow through

More information

Instruction. Vacuum Circuit Breaker Operator Module. Type 3AH 4.16kV to 38kV. Power Transmission & Distribution

Instruction. Vacuum Circuit Breaker Operator Module. Type 3AH 4.16kV to 38kV. Power Transmission & Distribution Instruction 0001-22-2--00 Vacuum Circuit Breaker Operator Module Type 3AH 4.16kV to 38kV Power Transmission & Distribution Hazardous voltages and high-speed moving parts. Will cause death, serious injury

More information

General Purpose Relays Types K, R, N, and C

General Purpose Relays Types K, R, N, and C General Purpose Relays s K, R, N, and C Catalog 0 Class 0 CONTENTS Description Page R Miniature Plug-in Relays..................................... K Plug-in Relays.............................................

More information

Digital Current Transducer HO-SW series I P N = A. Ref: HO 100-SW; HO 150-SW; HO 200-SW; HO 250-SW

Digital Current Transducer HO-SW series I P N = A. Ref: HO 100-SW; HO 150-SW; HO 200-SW; HO 250-SW Digital Current Transducer HO-SW series I P N = 100... 250 A Ref: HO 100-SW; HO 150-SW; HO 200-SW; HO 250-SW Bitstream output from on onboard Sigma Delta modulator. For the electronic measurement of current:

More information

NR2 Thermal Overload Relay

NR2 Thermal Overload Relay Contactors,, Starters. Type designation N - Current class Design sequence No. N Thermal Overload elay. General. Certificates: CE, KEM, UkrSEPO, GOST, CC, UL;. Electric ratings: C 0/0z, 90V, 0.~30;.3 Tripping

More information

VK2 volume flow controller Overview

VK2 volume flow controller Overview New option with sound attenuator Maintenance-free VK2 volume flow controller that operates without an auxiliary power supply, for ventilation and air conditioning systems. Adjustable on site. Outstanding

More information

Amphenol. Amphenol-Tuchel Electronics GmbH. Series C 146 Heavy Duty Connectors Core Programme

Amphenol. Amphenol-Tuchel Electronics GmbH. Series C 146 Heavy Duty Connectors Core Programme Amphenol Amphenol-Tuchel Electronics GmbH Series C 146 Heavy Duty Connectors Core Programme The Company General information These connectors are designed and produced in conformity with the voltage directive

More information

Ref: HLSR 16-PW; HLSR 32-PW; HLSR 40-PW-000; HLSR 50-PW-000,

Ref: HLSR 16-PW; HLSR 32-PW; HLSR 40-PW-000; HLSR 50-PW-000, Digital Current Transducer HLSR-PW series I P N = 16... 50 A Ref: HLSR 16-PW; HLSR 32-PW; HLSR 40-PW-000; HLSR 50-PW-000, Bitstream output from on onboard Sigma Delta modulator. For the electronic measurement

More information

MODEL: R7K4FML3. Remote I/O R7K4F Series. POWER INPUT DC power R: 24 V DC (Operational voltage range: ±10 %; ripple 10 %p-p max.)

MODEL: R7K4FML3. Remote I/O R7K4F Series. POWER INPUT DC power R: 24 V DC (Operational voltage range: ±10 %; ripple 10 %p-p max.) Remote I/O R7KF Series I/O MODULE (-III) POWER INPUT DC power R: V DC (Operational voltage range: ±0 %; ripple 0 %p-p max.) 0 (8.7). (.) 7(.8) mm (inch) [] OPTIONS (multiple selections) Output data read

More information

NH fuse-links gg 500VAC double indicator/live tags size 000, 00, 0, 1, 2, 3

NH fuse-links gg 500VAC double indicator/live tags size 000, 00, 0, 1, 2, 3 NH fuse-links gg VAC IEC NH Fuse-Links The NH system is classified among plug-in fuse systems and is composed of: fuse-base (possibly including terminal covers and phase barriers) fuse-link with blade

More information

TEST REPORT IEC/EN Circuit-breakers for over current protection for household and similar installations

TEST REPORT IEC/EN Circuit-breakers for over current protection for household and similar installations Test Report issued under the responsibility of: TEST REORT IEC/EN 60898-1 Circuit-breakers for over current protection for household and similar installations Report Reference No.... : 130100913SHA-004

More information

TeSys DF IEC-Type Fuseholders

TeSys DF IEC-Type Fuseholders TeSys DF IEC-Type 9080CT080 08 Contents... Page Characteristics......3 Accessories... Dimensions...5 Wirg diagrams...5 Fuses...6 7 Characteristics TeSys DF IEC-Type Fuseholder type DF8 DF0 DF DF DFCC Environment

More information

CDS. high density spring connection

CDS. high density spring connection CDS high density spring connection DENSTY STANDARD 1A CDS DENSTY A A spring connection CDS Series The originality of multipole connectors represents one of the core values of LE, a leading company in this

More information