BETA Protecting. Low-Voltage Fuse Systems. LV HRC fuse links. 3/36 Siemens ET B1 2008
|
|
- Abigail Jasmine Jennings
- 6 years ago
- Views:
Transcription
1 LV HRC fuse links Overview LV HRC fuses are used for installation systems in non-residential, commercial and industrial buildings as well as in switchboards of power supply companies. They therefore protect essential building parts and installations. LV HRC fuses are fuse systems designed for operation by scilled personnel. There are no constructional requirements for non-interchangeability of rated current and touch protection. The components and auxiliary equipment are designed in such a way as to ensure the safe replacement of LV HRC fuses or isolation of systems. LV HRC fuse links are available in the sizes 000, 00, 0,,,, and a. LV HRC fuse links are available in the following operational classes: gg for cable and line protection am for the short-circuit protection of switching devices in motor circuits gr or ar for the protection of power semiconductors gs: The new gs operational class combines cable and line protection with semiconductor protection. LV HRC fuse links of size 000 can also be used in LV HRC fuse bases, LV HRC fuse switch disconnectors, LV HRC fuse strips as well as in LV HRC in-line fuse switch disconnectors of size 00. The fuse links 00 A, A and A comply with the standard but do not have the VDE mark. LV HRC components I_ $ LV HRC fuse base from the SR0 busbar system % LV HRC fuse base for busbar mounting & LV HRC fuse base, P ( LV HRC fuse base, P ) LV HRC contact covers * LV HRC fuse link + LV HRC signal detectors, LV HRC partition - LV HRC protective cover with slewing equipment,. - for screw fixing on mounting plate / - for screw fixing on busbar system 0 - for claw fixing on busbar /LV HRC protective cover for with slewing equipment LV HRC slewing equipment LV HRC fuse base cover LV HRC isolating link with insulated grip lugs LV HRC isolating link with non-insulated grip lugs LV HRC fuse puller with sleeve LV HRC fuse puller / Siemens ET B 00
2 Benefits LV HRC fuse links Tripped Not tripped Tripped Not tripped LV HRC fuse links with combination alarm signal the tripping of a fuse by a clear color change from red to white. This enables fast identification and replacement of the tripped fuse links. This increases plant availability The insulated grip lugs made of metal are integrated in the top and bottom covers of the fuse link in molded plastic and provide greater safety during replacment. The mark shown below indicates that the grip lugs are insulated Technical specifications LV HRC fuse links Operational class gg In the standard series with front indicator, the front-mounted red indicator signals the tripping of a fuse. LV HRC fuse links are always equipped with silver-plated contact blades. This means that they are non-corroding and have less contact resistance. This ensures the long-term operational safety of the plant. Operational class am NA...- NA...- NA...- NA...- NA...- ND NA...-KK NA...- NA...- ND NY.. Standards IEC 0-, -; EN 0-; DIN VDE 0 Approved acc. to DIN VDE 0-; CSA. No., File No. 0 Rated voltage U n Sizes 000 and 00 V AC V DC Sizes and V AC V DC Size V AC V DC 0 -- Sizes (IEC design) V AC and a V DC Rated current I n A Rated breaking capacity ka AC ka DC Contact pins Non-corroding, silver-plated Resistance to climate C at % relative humidity Siemens ET B 00 /
3 LV HRC fuse links Selection and ordering data Insulated grip lugs Sizes Mounting width I n U n DT Order No. Price PG PU PS*/ P. unit Weight per P. unit approx mm A V AC/ VDC Unit(s) Unit(s) kg LV HRC fuse links with combination alarm, operational class gg /-- B NA B NA B NA B NA B NA B NA B NA B NA B NA B NA B NA /-- B NA -KK B NA 0-KK B NA B NA /-- B NA B NA B NA B NA B NA B NA B NA B NA B NA B NA B NA /-- B NA B NA B NA B NA B NA B NA B NA B NA B NA B NA B NA B NA B NA / Siemens ET B 00
4 Size Mounting width Non-insulated grip lugs I n U n DT Order No. Price Insulated grip lugs PG DT Order No. Price LV HRC fuse links PG PU PS*/ P. unit Siemens ET B 00 Weight per P. unit approx A VAC/ VDC Unit(s) Unit(s) kg LV HRC fuse links with combination alarm, operational class gg / B NA 0 0 B NA B NA 0 0 B NA B NA 0 0 B NA B NA 0 0 B NA } NA 0 0 } NA } NA 0 0 } NA } NA 0 } NA B NA 0 B NA 0 0. } NA 0 } NA B NA 0 B NA } NA 0 0 } NA } NA 0 } NA } NA 0 } NA } NA 0 0 } NA / B NA - 0 B NA B NA 0-0 B NA } NA 0 } NA } NA 0 A NA / B NA 0 B NA B NA 0 B NA B NA 0 0 B NA B NA 0 B NA B NA 0 B NA B NA 0 B NA B NA 0 B NA B NA 0 } NA B NA 0 } NA } NA 0 } NA } NA 0 } NA } NA 0 } NA B NA 0 B NA } NA 0 } NA / B NA 0 B NA B NA 0 0 B NA B NA 0 B NA B NA 0 B NA B NA 0 0 B NA B NA 0 B NA } NA 0 } NA } NA 0 0 } NA B NA 0 B NA } NA 0 } NA B NA } NA 0 } NA B NA } NA 0 0 } NA /
5 LV HRC fuse links Size Mounting width /0 Siemens ET B 00 Non-insulated grip lugs I n U n DT Order No. Price Insulated grip lugs PG DT Order No. Price PG PU PS*/ P. unit Weight per P. unit approx A VAC/ VDC Unit(s) Unit(s) kg LV HRC fuse links with combination alarm, operational class gg 000 0/ B NA 0-0 B NA B NA 0-0 B NA B NA 0-0 B NA B NA 0-0 B NA B NA 0-0 B NA B NA 0-0 B NA B NA - 0 B NA B NA - 0 B NA B NA - 0 B NA / B NA - 0 B NA B NA 0-0 B NA B NA - 0 B NA B NA - 0 B NA B NA 0-0 B NA / B NA - 0 B NA B NA - 0 B NA B NA - 0 B NA B NA - 0 B NA B NA - 0 B NA B NA - 0 B NA B NA - 0 B NA / B NA - 0 B NA B NA 0-0 B NA B NA - 0 B NA B NA - 0 B NA B NA 0-0 B NA B NA - 0 B NA B NA - 0 B NA B NA 0-0 B NA B NA - 0 B NA
6 Sizes Mounting width Non-insulated grip lugs I n U n DT Order No. Price LV HRC fuse links PG PU PS*/ P. unit Weight per P. unit approx mm A V AC/ VDC Unit(s) Unit(s) kg LV HRC fuse links with front indicator, operational class gg /0 } NA } NA } NA } NA } NA } NA } NA 0 0. } NA 0 0. } NA 0 / } NA } NA 0 0 /0 0. } NA 0 / } NA 0 / } NA 0 0 / /-- A NY 0 0. B NY /0 B NA B NA B NA B NA B NA } NA 0 0. } NA /0 B NA B NA B NA B NA B NA B NA B NA B NA B NA A NA B NA A NA A NA A NA /0 B NA B NA B NA B NA B NA B NA } NA } NA } NA } NA } NA } NA A NA } NA Siemens ET B 00 /
7 LV HRC fuse links Sizes Mounting width Non-insulated grip lugs I n U n DT Order No. Price PG PU PS*/ P. unit Weight per P. unit approx mm A V AC/ VDC Unit(s) Unit(s) kg. 00/0 B NA B NA A NA A NA A NA A NA 0 0. } NA } NA } NA } NA A NA } NA 0 0. } NA } NA /0 B NA B NA A NA B NA } NA 0 0. A NA } NA A NA } NA } NA Can only be used for NH 0 LV HRC fuse base (IEC design). 0 00/0 B NA A NA A NA A NA 0.00 Can only be used for NH 0 LV HRC fuse base a /0 B NA B NA A NA A NA A NA 0.0 / Siemens ET B 00
8 Sizes Mounting width Non-insulated grip lugs I n U n DT Order No. Price LV HRC fuse links PG PU PS*/ P. unit Weight per P. unit approx mm A V AC/ VDC Unit(s) Unit(s) kg 000 0/0 } NA } NA } NA } NA } NA } NA } NA B NA } NA /0 B NA } NA } NA } NA } NA /0 B NA B NA B NA } NA } NA } NA } NA /0 B NA B NA B NA } NA } NA B NA } NA B NA } NA /0 B NA B NA B NA } NA B NA } NA Siemens ET B 00 /
9 LV HRC fuse links Sizes Mounting width Non-insulated grip lugs I n U n DT Order No. Price PG PU PS*/ P. unit Weight per P. unit approx mm A V AC/ VDC Unit(s) Unit(s) kg LV HRC fuse links with front indicator, operational class am /-- B ND B ND B ND B ND B ND 0 0. B ND 0 0. B ND B ND B ND B ND B ND /-- B ND B ND 0 0. B ND /-- B ND B ND B ND B ND B ND B ND B ND /-- B ND B ND B ND B ND B ND B ND A ND /-- B ND B ND B ND B ND B ND / Siemens ET B 00
10 LV HRC fuse links Dimensional drawings LV HRC fuse links, operational class gg Sizes 000 to and a t Sizes I n U n Type Dimensions t A V b h h t t I_ h h b Size (IEC design) 0 I_ V AC/0 V DC NA../ V AC/0 V DC NA V AC/0 V DC NA AC NA V AC/0 V DC NA V AC/0 V DC NA V AC/0 V DC NA V AC/0 V DC NA V AC/0 V DC NA V AC/0 V DC NA../ AC NA..- (KK) V AC/0 V DC NA V AC/0 V DC NA../ V AC/0 V DC NA V AC/0 V DC NA V AC/0 V DC NA V AC/0 V DC NA V AC/0 V DC NA AC NA V AC/0 V DC NA V AC/0 V DC NA V AC/0 V DC NA V AC/0 V DC NA V AC/0 V DC NA V AC/0 V DC NA AC NA V AC/0 V DC NA V AC/0 V DC NA V AC/0 V DC NA V AC/0 V DC NA V AC/0 V DC NA V AC/0 V DC NA AC NA V AC/0 V DC NA V AC/0 V DC NA V AC/0 V DC NA V AC/0 V DC NA V AC/0 V DC NA V AC/0 V DC NA AC NA V AC/0 V DC NA V AC/0 V DC NA V AC/0 V DC NA V AC/0 V DC NA.. 0, 0 V AC/0 V DC NA V AC/0 V DC NA V AC/0 V DC NA V AC/0 V DC NA.. See adjacent drawing a V AC/0 V DC NA Siemens ET B 00 /
11 LV HRC fuse links LV HRC fuse links, operational class am Size 000 to t t I_ h h b Sizes I n U n Type Dimensions A V b h h t t AC ND AC ND AC ND AC ND.. 00, 0 ND.. 0 / Siemens ET B 00
12 Overview LV HRC signal detectors are used for remote indication that the LV HRC fuse links have been tripped. different solutions are available: NX 0 signal detectors with signal detector link NX 0 signal detector top TT fuse monitors. The LV HRC signal detectors with signal detector link support monitoring of LV HRC fuse links with non-insulated grip lugs of sizes 000 to at A or more. Benefits LV HRC signal detectors reliably indicate when a fuse has tripped. Tripped fuses are quickly located. This saves time and increases plant availability. $ LV HRC fuse link % Signal detector & Microswitch ( Spring contact ) Hinged lid * Signal detector links Selection and ordering data I_ LV HRC signal detectors The signal detector link is connected in parallel to the LV HRC fuse link. In the event of a fault, the LV HRC fuse links are released simultaneously with the LV HRC fuse signaling link. A tripping pin switches a floating microswitch. The signal detector top can be used with LV HRC fuse links, sizes 000, 00, and, which are equipped with non-insulated grip lugs and have a front indicator or combination alarm. It is simply plugged into the grip lugs. If a fuse is tripped, the front indicator springs open and switches a floating microswitch. This solution should not be used for safetyrelevant plants. For this purpose, we recommend our electronic fuse monitors. $ LV HRC fuse link % Front indicator & Signal detector tops ( Rocker/lever arm ( & $ % Sizes DT Order No. Price PG PU PS*/ P. unit Siemens ET B 00 Weight per P. unit approx Unit(s) Unit(s) kg LV HRC signal detectors A NX Only for SIEMENS NA, NA and ND LV HRC fuse links with non-insulated grip lugs Rated voltage up to 0 V AC/00 V DC Contact: microswitch 0 V AC, A Connection: flat termination. mm Signal detector links Rated voltage up to 0 V AC/ 00 V DC Response value > V;. A; A NX for standard applications Response value > V; A; C NX only for meshed networks Signal detector tops 000, 00,, } NX Only for SIEMENS NA, NA and ND LV HRC fuse links with non-insulated grip lugs Rated voltage up to 0 V AC/00 V DC Contact: microswitch 0 V AC, A, CO Connection: flat termination. mm /
13 LV HRC signal detectors U e I n U c MW DT Order No. Price PG PU PS*/ P. unit Weight per P. unit approx VAC A V Unit(s) Unit(s) kg Fuse monitors For all low-voltage fuse systems. Can be used in asymmetric systems afflicted with harmonics and regenerative feedback motors. Alarm also for disconnected loads. 0 x 0... } TT For more information on fuse monitors, please refer to the chapter "Monitoring of plants and devices". Dimensional drawings LV HRC signal detectors Signal detector links Signal detector tops NX 0 NX 0, NX 0 NX 0! # I_0a I_0a 0 #! # # #! # " # Fuse monitors TT L L L 0 L L L I_ Schematics LV HRC signal detectors Signal detector top NX 0 NX 0 Fuse monitors TT N NO NC / Siemens ET B 00
14 Overview Terminals for all applications Terminals are as different as the requirements of individual systems. Flat terminals with screws are suitable for connecting busbars or cable lugs. They have a torsion-proof screw connection with shim, spring washer and nut. When tightening the nut, always ensure compliance with the specified torque due to the considerable leverage effect. The double busbar terminal differs from the flat connection in that it supports connection of two busbars, one on the top and one at the bottom of the flat connection. In the case of flat terminal with nut, connection of the nut to the terminal lug is torsion-proof. When tightening the nut, the torque must be observed because of the considerable leverage effect. The plug-in terminal is equipped for connecting two conductors. The modern box terminal ensures efficient and reliable connection to the conductors. They support connection of conductors with or without end sleeves. Up to three conductors can be clamped to the terminal strip. One conductor can be clamped to the saddle-type terminal. Siemens ET B 00 /
15 Benefits The silver-plated Lyra contact provides a large contact area for the contact pin of the LV HRC fuse link. This improves heat transmission and lowers the temperature. It also minimizes ageing of the fuse link in the maximum load range, in particular when using SITOR fuses The large contact area also facilitates replacement of LV HRC fuse links The spring washer tensioning the contact is mechanically galvanized. This will prevent hydrogen embrittlement. The contact is resistant to aging and there will be no dreaded annealing of contacts, which considerably improves operating safety. Technical specifications, LV HRC bus-mounting bases Size 000/00 0 a Standards IEC 0-, -; EN 0-; DIN VDE 0- Rated current I n A Rated voltage U n V AC 0 0 (Also suitable for 00 V SITOR fuse links) V DC 0 0 Rated breaking capacity ka AC ka DC Flat terminals Screw M M M M Nut M -- Max. tightening torque Nm Plug-in terminals Conductor cross-section mm Saddle-type terminals Conductor cross-section mm Box terminals Conductor cross-section mm Terminal strip Conductor cross-section, -wire mm Max. torque for attachment of LV HRC fuse base Nm. -- with slewing equipment with slewing equipment Size 000/00 / a Rated voltage U n V AC 0 V DC 0 Power loss W 0 Flat terminals Screw M M M M Nut M -- Max. tightening torque Nm /0 Siemens ET B 00
16 Selection and ordering data Sizes I n Version DT Order No. Price PG PU PS*/ P. unit Weight per P. unit approx A Unit(s) Unit(s) kg Made of molded plastic, for standard rail mounting or screw fixing 000/00 P With flat terminals, screw } NH 0 0 / 0. With saddle-type terminals } NH 0 0 / 0. With box terminals, up to 0 mm } NH 0 0 / 0. Made of ceramic for screw fixing P With flat terminals, screw } NH With plug-in terminals B NH With saddle-type terminals } NH With flat terminals and terminal strip B NH With flat terminals, nut B NH With flat and saddle-type terminals B NH Made of molded plastic, for standard rail mounting and screw fixing P With flat terminals } NH With plug-in terminals B NH With saddle-type terminals B NH With flat terminals and terminal strip B NH P With flat terminals A NH With plug-in terminals B NH P With flat terminals } NH With double busbar terminals B NH P With flat terminals A NH P With flat terminals } NH With double busbar terminals A NH P With flat terminals } NH With double busbar terminals A NH Siemens ET B 00 /
17 Sizes I n Version DT Order No. Price PG PU PS*/ P. unit Weight per P. unit approx A Unit(s) Unit(s) kg 0 P (IEC design) With flat terminals A NH LV HRC bus-mounting bases for busbars x mm to x mm, Busbar spacing 0 mm 000/00 P With top saddle-type terminals B NH With bottom saddle-type terminals B NH Terminal strip, top B NH /00 0 P, in tandem design outgoing feeders, top and bottom With saddle-type terminals With barriers B NH With non-interrupted barriers B NH with slewing equipment With flat terminal and additional saddle-type terminals (included) 000/00 P With screw fixing for mounting plate A NH With claw fixing for non-perforated B NH 0 0 /.000 busbar With screw fixing for perforated busbar B NH 0 0 / With screw fixing for mounting plate A NH With claw fixing for non-perforated B NH 0.00 busbar With screw fixing for perforated busbar B NH 0.00 Can also be used for fuse links of size 0 With screw fixing for mounting plate B NH With claw fixing for non-perforated B NH 0.00 busbar With screw fixing for perforated busbar, can be used as disconnector B NH 0.00 / Siemens ET B 00
18 Sizes I n Version DT Order No. Price a A 0 With screw fixing for mounting plate PG PU PS*/ P. unit Weight per P. unit approx Unit(s) Unit(s) kg A NH LV HRC contact covers for 000/00 Touch protection for contact pieces } NX 0 / B NX 0 /0 0.0 } NX 0 /0 0.0 } NX 0 / 0.0 } NX 0 / 0.0 LV HRC partitions for As intermediate phase and end barrier 000/00 Type NH 0/NH 0 } NX NH B NX NH } NX NH } NX NH } NX LV HRC protective covers IPX For 000/00 P and P B NX LV HRC covers For plugging into IPX LV HRC protective covers B NX LV HRC contact covers for LV HRC bus-mounting bases Touch protection for contact pieces Outgoing terminal } NX 0 /0 0.0 Incoming terminal B NX 0 / LV HRC partitions for NH 0 LV HRC bus-mounting bases As phase barrier C NX As end barrier C NX 0 0 / Siemens ET B 00 /
19 Sizes Version DT Order No. Price PG PU PS*/ P. unit Weight per P. unit approx Unit(s) Unit(s) kg Non-interrupted barriers For NH 0 LV HRC bus-mounting bases C NX 0 0 / Fuse pullers For LV HRC fuse links Without sleeve } NX With sleeve } NX Isolating links For and fuse switch disconnectors With insulated grip lugs 000/00 Silver-plated } NG 00 0 / C NG 0 / 0.0 } NG 0 0 / 0. } NG 0 0 / 0.0 } NG 0 0 / 0.0 With non-insulated grip lugs Tinned B NG a Nickel-plated B NG 0 0 / 0.0 Fuse-base covers For, red with yellow inscription (German) "Power supply isolating point" 000/00 C NX ,, C NX / Siemens ET B 00
20 Dimensional drawings Size 000/00 to b b h h I_ t t t ) Size LV HRC fuse links are also screwed onto the base. ) LV HRC bus-mounting bases are only connected on one side using terminals, the second connection is made through the bottom of the base. NH 0 NH 0 NH 0 Sizes I n Num- Connection Type Dimensions ber of poles Size ) A b b h h t t t LV HRC bus-mounting base ) P b b b b h h h I_ t t t t t t I_,,, I_ 0,,, 000/00 P M plug-in terminal NH Saddle-type terminal Flat terminal P M plug-in terminal NH Saddle-type terminal Flat terminal P Saddle-type terminal LV HRC bus Terminal strip mounting base ) NH P Flat terminal NH Plug terminal 0 0 P M flat terminal NH.. 0 Double busbar terminal P M flat terminal NH.. 00 P M flat terminal NH Double busbar terminal 0 P M flat terminal NH.. Double busbar terminal 0 P M flat terminal NH max. 0 ) a Can only be used in bases with slewing equipment I_,, Siemens ET B 00 I_0 /
21 LV HRC bus-mounting bases in tandem design Busbar center-to-center clearance 0 mm NH 0, NH 0 with slewing equipment Sizes 000/00 to a d c m b, 0 l e I_ I_0a a n o Sizes I n Type Dimensions A a b c d e l m n o 000/00 NH NH / 0 NH a 0 NH / Siemens ET B 00
22 LV HRC contact covers for Sizes 000/00 to, NX b e c a d Sizes Type Dimensions a b c d e 000/00 NX.. 0 NX.. NX NX... NX LV HRC protective cover, with NX LV HRC cover Size 000/00, degree of protection IPX I_ I_ LV HRC contact covers for LV HRC bus-mounting bases for -pole version and tandem design, NX, 0 LV HRC partitions Size 000/00 Sizes 0 to NX 0 NX 00, NX 0 to NX 0 Sizes Type Dimensions a b c d 0 NX NX NX NX P, NX LV HRC partitions Phase barriers End barrier For in tandem design NX 0 NX 0 NX 0 I_0a I_ I_00a,,, 0 0, 0 I_0a I_ Siemens ET B 00 /
23 Fuse puller Sizes 000 to NX 0 (without sleeve), NX 0 (with sleeve) Sleeve, I_00a,, 0 Isolating links With insulated grip lug, sizes 000/00 to NG.0 Sizes Type Dimensions a b c d e f g h g h a e d 000/00 NG NG NG 0 0 NG 0 0 NG 0 0 b I_00 f, c Isolating links with non-insulated grip lugs Size Size a NG 0 NG 0 I_0a , I_0a 0 0 / Siemens ET B 00
24 More information Space requirements when installing LV HRC fuse base, P, P LV HRC partition I_ ) Placing an additional base on the barrier and plug-on part does not increase the distance, rather the bases lie flat directly on top of one another. ) This measurement specifies the required overall mounting depth with base d and the overall mounting height h. ) If the bases are installed directly on a side wall in the distribution board, one spacer part can be broken off. This would reduce the distance measurement. I_ I_ Sizes Mounting width (mm) of Mounting height (mm) unit, P units, P Distance through spacer Base with phase barrier, without end barrier Base with phase and end barriers Base with phase barrier, without end barrier Base with phase and end barriers d h Siemens ET B 00 Partition Spacer Mounting depth (mm) NX 0.. partitions with matching bases ) h d 000/00 0 ) LV HRC bus-mounting bases see page / Installation without barriers; for mounting see page / n/a a Can only be used in bases with slewing equipment n/a /
25 D Drill hole dimensions for base plate mounting, Sizes 000/00 and 0 I_ b l h h h Sizes to! # > > D D > > Size l h h h Sizes Type Dimensions b b h h l 000/00 NH NH... NH.. 0. NH NH.. 0. NH 0 0 I_ b b b, P Size 000/00 Size I_ l h I_ h Sizes Type Dimensions b b h h l 000/00 NH NH 0 0. h l h h b b b b b b /0 Siemens ET B 00
26 Drill hole dimensions for base plate mounting, units, P Sizes 000/00 and 0 I_ b b Sizes, and b l b h h h Sizes Type Dimensions b b b h h l 000/00 NH NH... NH NH NH NH 0 0 I_ l h h h b b b b b b Size I_ a a l h h h b b b b b b b Note: These are mounted without phase barriers. A minimum clearance of a = mm is required. Siemens ET B 00 /
27 f f f Space requirements when installing LV HRC bus-mounting bases Space requirements for -piece, -pole LV HRC bus-mounting bases, staggered I_ Saddle-type terminal connection: Terminal strip: Drill hole dimensions for base plate mounting Size 000/00 Sizes and / Size a p p k I_ g k I_ g g k I_0 h h h h h h h h h Sizes I n Type Dimensions A f g h h k p 000/00 NH NH.. 0. / 0 NH a 0 NH / Siemens ET B 00
5SJ4...-.HG Circuit Breakers to IEC and UL 489
Siemens AG 009 5SJ...-.HG Circuit Breakers to IEC and UL 89 BETA Low-Voltage Circuit Protection Compliance with industry standards is a must in today's manufacturing environment. Worldwide acceptance is
More informationBETA Protecting Miniature Circuit Breakers
Siemens AG 00 / Product overview / High-capacity range 000 A 0000 A 0000 A, high current 0000 A, universal current 000 A ka /0 Comfort range with plug-in terminal / Compact range +N in MW / Additional
More informationVarius SUMMARY OF MODELS OF HRC FUSE-LINKS
SUMMARY OF MODELS OF HRC FUSE-LINKS Type PNA000 PHNA000 PNA00 PHNA00 Rated current I n up to A up to 0 A up to A up to 0 A Rated voltage U n AC 00 V, 00 V 90 V 00 V 90 V DC 0 V 0 V 0 V 0 V Fuse-link size
More informationSiemens AG Miniature Circuit Breakers. Totally Integrated Power SENTRON. Configuration. Edition 10/2014. Manual. siemens.
Siemens AG 05 Totally Integrated Power SENTRON Configuration Manual Edition 0/0 siemens.com/lowvoltage Siemens AG 05 Siemens AG 05 Introduction 5SL miniature circuit breakers 5SY and 5SP miniature circuit
More informationThermal-Magnetic Circuit Breaker 2210-T2...
Thermal-Magnetic Circuit Breaker 0-T... Description One, two and three pole thermal-magnetic circuit breakers with trip-free mechanism and toggle actuation (S-type TM CBE to EN 6094/IEC 94). Featuring
More information5SP and 5SY Supplementary Protection UL 1077
Product Guide 5SP and 5SY Supplementary Protection UL 077 for North merican and International applications usa.siemens.com/5sy Table of contents Certifications, standards, features and description Characteristic
More informationThermal-Magnetic Circuit Breaker 2210-S2..
Thermal-Magnetic Circuit Breaker -S.. Description One, two and three pole thermal-magnetic circuit breakers with trip-free mechanism and toggle actuation (S-type TM CBE to EN 60934/IEC 934). Designed for
More informationThermal-Magnetic Circuit Breaker 2210-S2..
Thermal-Magnetic Circuit Breaker -S.. Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 60934/IEC 934). Designed for
More informationThermal-Magnetic Circuit Breaker 2210-S2..
Thermal-Magnetic Circuit Breaker -S.. Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 6094/IEC 94). Designed for
More informationMagnetic and Hydraulic-Magnetic Circuit Breaker 8340-T...
Magnetic and Hydraulic-Magnetic Circuit Breaker 830-T... Description ngle, two and three pole magnetic and hydraulic-magnetic circuit breakers with trip-free mechanism and toggle actuation. A choice of
More informationThermal-Magnetic Circuit Breaker 2210-S2...
Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 6094/IEC 94). Designed for panel or plug-in mounting. Available
More informationThermal-Magnetic Circuit Breaker 2210-S2...
Thermal-Magnetic Circuit Breaker 0-S... Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 60934/IEC 934). Designed
More informationOverload Relays. SIRIUS 3RU1 Thermal Overload Relays. 3RU11 for standard applications. 5/46 Siemens LV 1 AO 2011
SIRIUS 3RU1 Thermal Overview 1 2 7 3 4 6 "Increased safety" type of EEx e according to ATEX directive 94/9/EC The 3RU11 thermal overload relays are suitable for the overload of explosion-proof motors with
More informationNH fuse-links gg 500VAC double indicator/live tags size 000, 00, 0, 1, 2, 3
NH fuse-links gg VAC IEC NH Fuse-Links The NH system is classified among plug-in fuse systems and is composed of: fuse-base (possibly including terminal covers and phase barriers) fuse-link with blade
More informationVX25 Enclosure System. Technical documentation PE conductor connection, current carrying capacity
VX Enclosure System Technical documentation PE conductor connection, current carrying capacity Enclosure system VX Contents Contents. General remarks. Introduction. Notes on the design of the earthing
More informationNon-Contact Safety Systems CMS
Selection table for non-contact safety system // Evaluation units Connection Desi Read head contact assembly Assured switch-on distance S ao [mm] Assured switch-on distance S ar [mm] Number of outputs
More informationFAZ tripping characteristics at 30 C: B, C, D to IEC/EN FAZ tripping characteristics at 30 C: R to IEC/EN
FAZ, AZ High-Capacity Tripping Characteristics Moeller HPL011-001/00 1/07 FAZ tripping characteristics at 0 C: B, C, D to IEC/EN 0 9 FAZ tripping characteristics at 0 C: R to IEC/EN 0 97 t [s] 700 00 100
More informationUL 1077 DIN Rail Supplementary Protectors
UL 0 DIN Rail Supplementary Protectors Product Overview UL 0 DIN Rail Supplementary Protectors PRODUCT OVERVIEW Product Overview Standard Features WMZS breaker terminals provide finger and back-of-hand
More information3VT4 Molded Case Circuit Breakers up to 1000 A
VT4 Molded Case Circuit Breakers up to 00 A Catalog Technical nformation VT4 Molded Case Circuit Breakers up to 00 A General data / - Overview Circuit breakers Switch disconnectors / - Selection and ordering
More informationMKV AC Capacitors Damping B High dielectric strength High peak-current capability Especially suitable for snubber circuits
MKV AC Capacitors B 25 835 High dielectric strength High peak-current capability Especially suitable for snubber circuits Construction Self-healing Plastic dielectric Oil-impregnated tubular windings (no
More informationMR medium rating busbar
technical information General features MR is fully compliant with S EN 0-, specifically, the rated current of the Zucchini busbar trunking systems is always rated at the average ambient temperature of
More informationMCB NB1-63H Miniature Circuit Breaker
NB-H Miniature Circuit Breaker. General. Function protection of circuits against short-circuit currents, protection of circuits against overload currents, switch, isolation, NB-H circuit-breakers are used
More informationSealing possibility Electrical endurance (ops) Mechanical endurance (ops) Overvoltage category Standards
Miniature circuit breaker ETIMAT 7,7 0.5 Rated voltage Rated current Rated frequency Rated short-circuit capacity Energy limiting class characteristic Build-in width Mounting on the rail 0/00 V AC, max.
More informationTeSys circuit-breakers
Presentation Thermal-magnetic motor circuit-breakers types GV2, GV and GV7 GV2-ME, GV2-P, GV-ME and GV7-R motor circuit-breakers are -pole thermal-magnetic circuit-breakers specifically designed for the
More informationVarius SUMMARY OF MODELS OF HRC FUSE-LINKS. Type PVA10 / PV10 PV14 PV22 Rated current I n up to 32 A up to 63 A up to 125 A Rated voltage U n
Varius SUMMARY OF MODELS OF HRC FUSE-LINKS Type A / Rated current I n up to A up to up to A Rated voltage U n AC V, V V, V, 9 V V, V, 9 V DC V V V Fuse-link size x8 x x8 Utilization category of the fuse-link
More informationAmphenol C 091 A/B/D. Circular Connectors. Amphenol-Tuchel Electronics GmbH
Amphenol C 091 A/B/D Circular Connectors Amphenol-Tuchel Electronics GmbH General information These connectors are designed and produced in conformity with the low-voltage directive (/3/EWG) respectively
More informationSemiconductor (AC) fuses
gr 690 VAC sizes 000 to (full range) Ferraz Shawmut PROTISTOR NH grb 690 VAC fuselinks provide maximum flexibility in equipment design and ultimate protection for today s power conversion equipment. This
More information08/072 PKZ2 Motor-Protective Circuit-Breakers Tripping Characteristics
0/07 PKZ Tripping Characteristics Moeller HPL0-00/00 S-PKZ high-capacity contact module, SEA-PKZ contact module Normal switching duty AC-/00V kw A Rated output of three-phase motors 0...0 Hz. 7..... 0.7
More information8 Installation Equipment
8 Installation Equipment Plugs and Sockets CES System Series 8, 88, 8, 881 Te plugs and sockets in te CES system comply wit CEE publication 1 and European standards EN 0 01. Te small 1 A socket as switcing
More informationBlocks and Holders POWR-BLOKS. Connectors. Ampere Ratings. Ordering Information. Applications. Specifications. Distribution/Splicer Blocks and Covers
Connectors Box lug connectors are designed for use with a single, solid or class B or C stranded conductor. Use of more than one conductor per connector opening or use of extra-flexible, fine stranded
More informationSingle point load cells
SP4M Single point load cells Special features Maximum capacities: kg 200 kg Aluminum High ratio of minimum verification Offcenter load compensation Shielded connection cable Explosion protection and other
More informationAmphenol. Amphenol-Tuchel Electronics GmbH. Circular Connectors C 091 A/B/D Series
Amphenol Amphenol-Tuchel Electronics GmbH Circular Connectors C 09 A/B/D Series The Company Amphenol-Tuchel Electronics GmbH is a member of the USA based Amphenol Corporation. With our own global presence
More informationGeneral characteristics, Products
The Feature Packed line of Manual Motor Protectors Eaton s new XT family of Manual Motor Protectors (MMPs) features a pushbutton or rotary ON/OFF manual disconnect, Class adjustable bimetallic overload
More informationLD-LP-LL-LC Rope Safety Switches with reset for emergency stop
TECHNICA DATASHEET D-P--C Rope Safety Switches with reset for emergency stop Metal or polymer housing, from one or three conduit entries Protection degree IP6 In conformity with EN ISO 13850 contact blocks
More informationFault Calculation Methods
ELEC9713 Industrial and Commercial Power Systems Fault Calculation Methods There are two major problems that can occur in electrical systems: these are open circuits and short circuits. Of the two, the
More informationUniversal limit switches
SWITCHES.CROUZET.COM 1 LIMIT SWITCHES 0/016 Universal limit switches 8384 standard 8384 with positive break operation Conformity to standards IEC / EN 60947--1, including Annex K for version with positive
More informationMasterpact. Installation recommendations
90 Installation recommendations Presentation Functions and characteristics 9 Dimensions and connection 5 Electrical diagrams 8 Operating conditions 92 Installation in switchboard 9 Door interlock catch
More informationSemiconductor (AC) fuses
gr - 690 VAC sizes 000 to (full range) Ferraz Shawmut PROTISTOR NH grb 690 VAC fuse-links provide maximum flexibility in equipment design and ultimate protection for today s power conversion equipment.
More informationSIRCOVER Manual transfer switches from 125 to 3200 A
Manual transfer switches svr_149_a 3200 A Function are manual multipolar transfer switches with positive break indication. The family includes two ranges: AC for dead time switching (I-0-II), for overlapping
More informationLoad Cells. 3/2 Introduction. 3/3 Mounting components 3/3 Introduction
Siemens AG 2018 /2 Introduction / Mounting components / Introduction /4 Single point load cells /4 Overview /5 SIWAREX WL260 SP-S AA /5 - Load cell /6 SIWAREX WL260 SP-S AB /6 - Load cell /7 SIWAREX WL260
More informationIssued August DATA SHEET. 3VT3 MCCB up to 630 A
ssued August 9 DATA SHEET VT MCCB up to 6 A Based on Siemens Catalog V 6 8 Circuit breakers Switch disconnectors Technical specifications Specifications Type VT 76-AA6/6/56-AA, VT 76-AA6/6/56-AA Circuit
More informationRequest Ensure that this Instruction Manual is delivered to the end users and the maintenance manager.
Request Ensure that this Instruction Manual is delivered to the end users and the maintenance manager. 1 -A - Introduction - Thank for your purchasing MITSUBISHI ELECTRIC MELPRO TM D Series Digital Protection
More informationSemiconductor (AC) fuses
Main characteristics 6,9 grb 7 PA 6,9 grb 73 TTF 000 + MS7V-5 UR Ferraz Shawmut PSC-gRB 690 VAC fuse-links provide maximum flexibility in equipment design and ultimate protection for today s power conversion
More informationX T O B P 1 6 B C 1 S
9 Overload Relays XTOB, XTOT May 07 Contents Description Page Overload Relays XTOB, XTOT Selection................ 9 Product Selection.......... 95 Accessories............... 9 Technical Data and Specifications............
More informationPushbutton Units and Indicator Lights
Insert labels and insert caps Clear, illuminated and indicator lights can be fitted with insert labels and caps for identification purposes. These labels and caps are made of a semi-transparent molded
More informationC60N circuit breakers0 B, C and D curves IEC 60898: 6000 A, IEC : 10 ka
C0N circuit breakers0 B, C and s IEC 0898: 000 A, IEC 097-: 0 ka Function b The circuit-breakers combine the following functions: v protection of circuits against short-circuit currents v protection of
More informationRemote Display Unit. Installers Handbook Copyright 2001 AirSense Technology Ltd. LM Remote Display Unit Installers Handbook Issue 1.
Remote Display Unit Installers Handbook Copyright 2001 AirSense Technology Ltd AirSense, ClassiFire, FastLearn PipeCAD, SenseNET, Stratos-HSSD and Stratos-Quadra are trademarks. HSSD is a Registered Trademark.
More informationPeriodic Inspection and Testing of Electrical Installations Sample Test ( ) Version 1.3 July 2018
Periodic Inspection and Testing of Electrical Installations Sample Test (2391-051) Version 1.3 July 2018 Sample Questions Version and date Change detail Section 1.3 July 2018 Modified questions/answers
More informationProtected. Main specifications. Additional specifications. Product adaptations
Protected 83 06 Double break switching Options for operation in stable positions Choice of actuators and fixing positions Main specifications Standard 83 06 0 stable lever positions 83 06 4 stable plunger
More informationSemiconductor (AC) fuses
PSC gr sizes 7x - 690 VAC Main characteristics 6,9 grb 71 PA 200 6,9 grb 73 TTF 1000 + MS7V1-5 UR Ferraz Shawmut PSC-gRB 690 VAC fuse-links provide maximum flexibility in equipment design and ultimate
More informationISOCON-6. 24V AC or DC POWERED ISOLATING SIGNAL CONVERTER
ISOCON-6 24V AC or DC POWERED ISOLATING SIGNAL CONVERTER Whilst every effort has been taken to ensure the accuracy of this document, we accept no responsibility for damage, injury, loss or expense resulting
More informationBASE. Rotary limit switch. OptiOnS. FEAtuRES. CERtiFiCAtiOnS
Rotary limit switch BASE Rotary limit switch used to control and measure the movement of industrial machines. Its compact size make it suitable for use in narrow spaces. FEAtuRES It consists of a gear
More informationGeneral characteristics
General characteristics This range of insulators and partition bushings provides for connecting and supporting low- and medium-voltage electrical equipment. - Their purpose is to provide electrical and
More informationDIM. A (+ 0,05 0,51) .135 ±.015 (3,43 ± 0,38) COMMON LUG INTEGRAL ASSEMBLY NUT, DO NOT REMOVE 1/4-32 UNEF-2A THREAD
Multi-Deck SERIES 0 SERIES 0 0." Diameter, / Amp, Standard, Military SR FEATURES Proven Quality in Thousands of Applications Gold-plated Contact System 0,,, 0 and 0 Angle Options MIL Qualified Versions
More informationTo order, specify : Types Protection functions Current surge Asymmetry and loss of phase. Operating principle
otor protection relays - T - FWIT Since % of -phase motor failures are due to load problems or loss of phase, the CROUZET range of motor protection relays is indispensable! models give motor protection
More informationElectric Field Mapping Lab 2. Precautions
TS 2-12-12 Electric Field Mapping Lab 2 1 Electric Field Mapping Lab 2 Equipment: mapping board, U-probe, resistive boards, templates, dc voltmeter (431B), 4 long leads, 16 V dc for wall strip Reading:
More informationTechnical catalogue SmiSSline electrical protective devices in a system
Technical catalogue SmiSSline electrical protective devices in a system SmiSSline The original Shaping the future SmiSSline protection devices are simply snapped into a plug-in socket system. The arduous
More informationInstallation Manual. Installation manual for PerfectEnergy Solar Modules. Content
Installation manual for PerfectEnergy Solar Modules Content 1. Preface 2. Technical data/general 3. Safety instructions 4. Mechanical Installation 5. Electrical installation 6. Grounding 7. Maintenance
More informationElectric Field Mapping
Electric Field Mapping Equipment: mapping board, U-probe, 5 resistive boards, templates, knob adjustable DC voltmeter, 4 long leads, 16 V DC for wall strip, 8 1/2 X 11 sheets of paper Reading: Topics of
More informationINFORMATION TECHNOLOGY SYSTEMS SPDs FOR 19 TECHNOLOGY. NET Protector Surge Arrester. Protects switches, HUBs and telecommunication
Surge Arrester Protects switches, HUBs and telecommunication systems Class D according to EN 0 possible (Gigabit Ethernet) Variably equippable patch panels Units available with plug-in inputs and outputs
More informationE6C-N. Ideal for Out-of-step Detection of Stepping Motors and Position Control of Rotors and Unloaders
Multi-turn High-precision Encoder Ideal for Out-of-step Detection of Stepping Motors and Position Control of Rotors and Unloaders Reset function for easy origin alignment when built-into equipment. Multi-turn
More informationInstallation guide 862 MIT / MIR
Installation guide 862 MIT / MIR in combination with: 864 MTT or 863 MRT or (dual) spot element November 2005 Part no. 4416.232_Rev3 Enraf BV PO Box 812 2600 AV Delft Netherlands Tel. : +31 15 2701 100
More information7S SERIES. Relay module with forcibly guided contacts 6 A 7S S /0310 7S
Relay module with forcibly guided contacts.12 with 2 pole (1NO + 1 N).14 with 4 pole (2 NO + 2 N and 3 NO + 1 N).16 with 6 pole (4 NO + 2 N) For safety applications, with class A forcibly guided contact
More informationATyS Automatic and remotely operated transfer switches from 125 to 3200 A
atys-p_001_b atys_d_001_a_1_cat ATyS p I-0-II 4P ATyS d I-0-II 4P Function The ATyS are three-phase motorised transfer switches with positive break indication. They enable the on load transfer of two three-phase
More informationCapacitors with screw terminals Long life industrial 85 C 12000h
FET2,FET4 Long Life Grade Capacitors Applications Uninterruptible power supplies Frequency converters FET2 FET4 For Wind power and Solar Power Features All-welded construction ensures reliable electrical
More informationELINEMK Technical Characteristics Rated Current Busbar Code Standards Rated Isolation Voltage Max. Rated Operational Voltage Rated Frequency Pollution Degree Protection Degree External Mechanical Impacts
More information40 CD RANGE FLUSH-MOUNTING DISTRIBUTION BOARDS AND ENCLOSURES
DISTRIBUTION BOARDS FLUSH-MOUNTING DISTRIBUTION BOARDS GWTEST SOFTWARE (see page 322) Complementary system items Ordinary installation - protected flush mounting DISTRIBUTION / JUNCTION Protection devices...
More information90 MCB MODULAR CIRCUIT BREAKERS FOR CIRCUIT PROTECTION
MCB - MTC - MT - MTHP Technical data TYPE MTC MT MTC45 MTC60 MTC100 MT 45 MT 60 Rated current (In) (A) 2-32 6-32 6-32 6-40 1-63 Utilization category A A A A A Rated operational voltage (Ue) (V) 230/400-240/415
More informationMiniature Circuit Breaker
Miniature Circuit Breaker SG-DPN I E C / E N 0 8 9 8-5 0 0 SG-DPN Applications Approval / Marking Function and Feature Integrate with switch phase and neutral in one module Protection against both overload
More informationCTV series CHARACTERISTICS LINEAR UNITS
CTV series CHARACTERISTICS The CTV series describes s with a precision ball screw drive and two parallel, integrated, Zerobacklash rail guides. Compact dimensions allow high performance features such as,
More informationFL ballasts Electronic fixed output. PC TC PRO sr 1/2x11 42 W PC PRO compact
FL ballasts EL HE PC TC PRO sr 1/2x11 42 W PC PRO compact Product description CELMA Energy Efficiency Index A2 BAT / A2 T Nominal life-time up to 50,000 h (at ta 50 C with a failure rate max. 0.2 % per
More informationInternal Components Forms of Separation
IEC 60439-1 One or more of the following conditions can be attained by dividing ASSEMBLIES by means of partitions or barriers (metallic or non-metallic) into separate compartments or enclosed protected
More informationC120N circuit-breakers B, C and D curves EN 60898/EN 61009: IEC : 10 ka
C0N circuit-breakers B, C and D curves EN 09/EN 009: 0000 - IEC 097-: 0 ka function # protection of cables against overloads and short-circuits in final distribution # manual control and isolation # earth
More informationRedline Unibis : the solution Circuit protection
2 circuits in 1 mo Redline Unibis : the solution ircuit protection Unibis compact Ms are one of the latest introductions in the Redline range and are developed to reduce the size of the distribution board
More informationIssued August DATA SHEET. 3VT5 MCCB up to 1600 A
ssued August 9 DATA SHEET VT5 MCCB up to 0 A Based on Siemens Catalog V 8 Standard circuit breakers Releases Technical specifications Specifications VT5 circuit breakers Switch disconnectors Type Standards
More informationPHOENIX CONTACT - 04/2016. Features
Signal conditioner Data sheet 100238_de_06 1 Description PHOENIX CONTACT - 04/2016 Features The MCR-C-UI-UI(-450)-DCI(-NC) 3-way isolation amplifier is used to electrically isolate and convert analog signals.
More informationProtistor size 30 ar VAC (IEC) / 700VAC (UL)
Protistor size 30 ar SEMICONDUCTOR PROTECTION FUSES SQUARE BODY HIGH-SPEED FUSE-LINKS AC PROTECTION FEATURES & BENEFITS Multiple body sizes and terminals or blades combination ar Class according to IEC
More informationAC axial compact fan
ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-7467 Mulfingen Phone +49 798 8-0 Fax +49 798 8-0 info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen County court Stuttgart HRA
More informationPerformance. Standards. Technical data
ilos Loadbreak disconnectors for INrail and wall mounting ilos up to ilos 2 up to los up to Order codes pplications pprovals / Marking ddon devices Performance INrail type and wall mounting type Main disconnector,
More informationSection Installation accessories. > UNION Series > TIES Series > FIXO Series > CABLO Series > FASTY Series > RAILDIN Series
Section > UNION Series > TIES Series > FIXO Series > CABLO Series > FASTY Series > RAILDIN Series 22 23 > CABLE GLANDS WITH DEVICE TO PREVENT ANY UNSCREWING UNION Series B (*) IP8 (1 bar) C A in mm A B
More informationF F FAULT CURRENT Prospective. 1. Introduction. 2. Types of fault conditions
FAULT CURRENT F F13-13 FAULT CURRENT - Contents 1. Introduction 2. Types of fault conditions 3 fault current must be determined 3.1 Purposes for which of prospective fault current magnitudes are used 3.2
More informationSwitches in conformity with ATEX directive
E Switches in conformity with ATEX directive page / General Catalog 09-0 Technical concepts page /9 A B Position switches FD series page / Category Zone Approvals Article code extension G M ATEX category
More informationSystem Extensions for Switchgear Manufacturing
System Extensions Switchgear Manufacturing As a specialist safety interfaces, EFEN provides a range of accessories to complement the assembly und application of safe power distribution systems. System
More informationSingle Phase Motors Technical Datasheets
Single Phase Motors Technical Datasheets EN A dynamic, strong and ambitious Group: Orange1 Holding is an international renown Group, one of the most important European manufacturers of single-phase and
More informationI nllk 08018/18 I nllk I nllk 08036/36 I nllk I I nllk 08058/58 I
I nllk / I x W x W x W x W x W Technical data Cooper Crouse-Hinds - all rights reserved nllk / nllk nllk / nllk nllk / Marking to //EC II G Ex na II T / II D td A IP T C EC Conformity Statement PTB ATEX
More informationMINIATURE MICROSWITCHES - PREMIUM
0/06 MINIATURE MICROSWITCHES - PREMIUM V - 86 High precision flexible leaf snap-action mechanism Operation without balance-point, even at extremely slow actuating speed Broad range of operating forces
More information90 MCB range Modular circuit breakers for circuit protection
MCB - MTC - MT - MTHP Technical data TYPE MTC MT MTC45 MTC60 MTC100 MT 45 MT 60 Rated current (In) (A) 2-32 6-32 6-32 6-40 1-63 Utilization category A A A A A Rated operational voltage (Ue) (V) 230 / 400
More informationTeSys enclosed starters 2
Characteristics, references TeSys enclosed starters D..L. starters for motor control 0. to. kw with -phase thermal overload relay with protected phases Characteristics () Conforming to standards IEC 0--,
More informationCapacitive Sensors. Contents
Contents Capacitive sensors detect the change in capacitance caused by the approach of an object. Their advantage lies in the ability to detect virtually any material, from metals to oils. 4.2 Definitions,
More informationProximity Sensor Ideal for High Temperatures and Cleaning Processes. Applicable to 120 C
ASH & ALAIN INDIA PVT LTD S-00, F.I.E.E., Okhla Industrial Area, Phase-ii, New Delhi-000(India) Tel : 0-797575 Fax : 0-79757 E-mail : sales@ashalain.com Proximity Ideal for High Temperatures and Cleaning
More informationSolenoid valves 2/2-way direct-operated type EV210A
MAKING MODERN LIVING POSSIBLE Data sheet Solenoid valves 2/2-way direct-operated type EV210A EV210A covers a wide range of small, direct-operated 2/2-way solenoid valves for use in industrial machinery.
More informationTHE DIMENSIONING OF ELECTRICAL CONDUCTORS FOR USE IN "PANEL BOARDS" ADDRESSED TO HAZARDOUS AREAS - PART THREE
July 04 THE DIMENSIONING OF ELECTRICAL CONDUCTORS FOR USE IN "PANEL BOARDS" ADDRESSED TO HAZARDOUS AREAS - PART THREE In this third part. we want to speak about how important is the correct sizing of the
More informationAmphenol Amphenol-Tuchel Electronics GmbH. C 091 A/B/D Series. Circular Connectors.
mphenol mphenol-tuchel Electronics GmbH C 09 //D Series Circular Connectors www.industrial-amphenol.com Note from the CEO Ladies and Gentlemen, For over years mphenol has enjoyed success as the interconnection
More information16 Input AC Block I/O Module
6 Input AC Module Cat. No. 79-6A0 Series B Installation Mount the block I/O module in a vertical (recommended) or horizontal position. Allow sufficient room around the block for cooling air flow through
More informationEX-EMERGENCY LIGHT FITTINGS
EX-EMERGENCY LIGHT FITTINGS nllk 0...N 1-36 W Plastic version for Zone 2 and Zone 21/22 The explosion-protected light fittings of the series nllk 0 N are conform to the requirements of the ATEX-Directive
More informationSpecifications. Voltage Ratings: Interrupting Rating: Applications. Inverters Re-combiner boxes. LFJ 1000VDC Solar Series
0 VDC 125-4A Specifications Description The SPFJ series is the smallest 0VDC 125-4A photovoltaic fuse available in the market. The SPFJ series is manufactured in Class J case sizes that allows for both
More informationmicroswitches Low force
0/06 Subminiature MICOSWITCHES - PEMIUM V - 870 High precision flexible leaf snap-action mechanism Operation without balance-point, even at extremely slow actuating speed atings from ma Vc up to (6) A
More informationDirect-operated 2/2-way compact solenoid valves Type EV210A
Data sheet Direct-operated 2/2-way compact solenoid valves Type EV210A EV210A covers a wide range of small, directoperated 2/2-way solenoid valves for use in industrial machinery. The compact design together
More informationXD1-L Cable Differential Protection Relay
XD1-L Cable Differential Protection Relay Manual XD1-L (Revision B) Woodward Manual XD1-L GB Woodward Governor Company reserves the right to update any portion of this publication at any time. Information
More informationCDS. high density spring connection
CDS high density spring connection DENSTY STANDARD 1A CDS DENSTY A A spring connection CDS Series The originality of multipole connectors represents one of the core values of LE, a leading company in this
More information