Configurable universal transducer for all power current variables and for mains synchronization PT - SU ENA10/ EN
|
|
- Bryce Ray
- 6 years ago
- Views:
Transcription
1 PT S EA08.54 E Configrable niversal transdcer for all power crrent variables and for mains synchronization Configrable transdcer for all power crrent variables, I, P, Q, S, cosφ, sinφ, φ, f 4 analog otpts and binary otpt 4 integrated energy conters Comparison of two mains voltages in terms of amplitde, freqency and phase (synchronoscope) Electrical safety to IEC standards Class 0.5 Different characteristics Correct reslts even with distorted sinsoidal inpt signal Parameterization and commnication via standard interface serfriendly parameterization software with online display of all variables
2 PT S Configrable niversal transdcer for all power crrent variables and for mains synchronization EA08.54 E Technical data Inpt Rated crrent A; A Rated voltage : 0 V < < 90 V or : 50 V < < 500 V : 5 V < < 490 V or : 00 V < < 850 V Measring range see ordering information Rated freqency 6 ⅔ Hz ± 0 % Internal power consmption Crrent inpt appro. 0.5 VA Voltage inpt appro..5 ma Overload capacity Crrent inpt: permanent I short term 40 I, however I Voltage inpt: ma. 00 A s permanent.5 however ma. 570 V ( ) short term 4 s Otpt mber of otpts mav switchable and binary or mav switchable and binary or 4 mav switchable and binary Crrent otpts adjstable between ± ma and ± 0 ma Crrent limit: ma. < 0 ma oad: RA 5 VIA Voltage otpts adjstable between ± V and ± 0 V Voltage limit: A ma. 7 V for RA Crrent limit: < 50 ma oad: RA > 5 kω Residal ripple < 0.5 % (peaktopeak) Response time s (adjstable via parameterization) Binary otpt (open collector) Plse otpt plsesh Rating 4 V DC00 ma Plse dration 0 ms oad 80 Ω Shortcircit proof Variables Crrent: Voltage: Active power: Reactive power: (sinsoidal signals) Reactive power: (nonsinsoidal signals) Apparent power: Freqency: cosφ: (sinsoidal signals) I, I, I,,,,, Mains Mains with synchronoscope Ptotal, P, P, P, with display of the energy direction (consmptiongeneration) Qtotal, Q, Q, Q with indication of capacitiveindctive load Qtotal, Q, Q, Q, withot sign Stotal, S, S, S Measrement in crrent or voltage path or F MainsFMains with synchronoscope with indication of capacitiveindctive load Active power factor: vale only, no load indication (nonsinsoidal signals) sinφ: (sinsoidal signals) with sign Reactive power factor: vale only (nonsinsoidal signals) Interfaces Serial front interface (SRS ) Optional fieldbs interface (RS 485) Commnication protocol MODBS RT Transient response Error limit ± 0.5 % Reference conditions F, IF I Freqency f ± % Form factor. Power factor (P: cosφ, Q: sinφ ) Power spply H ± % oad for IA: 0.5 R A ma. Ambient temperatre C ± Warmp time appro. 0 min. Effects Overranging.fold: 0. %, fold: 0.5 % Crve shape: crest factor...6 (parameterizable) Power spply: 0.05 % Eternal magnetic field: 0.5 % p to 400 Am Temperatre: 0. %0 Phase angle: Energy conter: φ, φ, φ, φtotal, φmains φmains with synchronoscope 4 independend conters (parameterizable) for crrent, active power (consmptiongeneration), reactive power (indctivecapacitive), apparent power Page of 9
3 PT S Configrable niversal transdcer for all power crrent variables and for mains synchronization EA08.54 E Technical data Power spply Voltage range: V ACDC 4 V ACDC Hosing, Monting, Connection Srface monting case AC: V; Hz; 5 VA DC: V; 5 VA AC: V; Hz; 5 VA DC: V; 5 VA Material hardly inflammable plastic (to V 94V), halogen free Connection terminals Crrent inpt 4 mm Others.5 mm Type of protection Hosing IP 40 Terminals IP 0 Weight appro kg Dimensions (W H D) 05 mm 95 mm 0 mm 9" plgin card Color Grey RA 70 Connection pin blade connector, type D and mltipoint connector for crrent connection Weight appro. 0.7 kg Monting width T (appro. 60 mm) General and safety data Basic standard for power transdcer to DI E or IEC 688 Safety information to DI E 600 or IEC 00 Test voltage inpt against otpt 5.55 kv, 5060 Hz Rated voltage against earth < 570 V doble, < 000 V basic inslation Degree of polltion Overvoltage category III against otpt III against inpt and power spply Otpt circits, interfaces For voltages < 570 V all otpt circits and the interfaces are fnctional etralow voltage circits to DI VDE 000, Part 40 (PEV). The safe isolation of these circits meets reqirements to DI VDE 006, Part 0. Electromagnetic compatibility to E 5008 or IEC 0004 Radio sppression to DI E 550 Mechanical capability Tested to DI IEC 687 and 686 Shoc: 0 g, ms Vibrations: g, Hz Environmental capabilities Climatic category to DI IEC 7 or DI E 607 Ambient temperatre range (5 to DI IEC 7) C Storage temperatre range (4 to DI IEC 7) C; light condensation allowed Page of 9
4 PT S Configrable niversal transdcer for all power crrent variables and for mains synchronization EA08.54 E Ordering information Type S Design Srface monting case Catalog o. V845A ER 00,00 Deliv. time wks. Measring circit Threephase nbalanced load (niversal type) or synchronoscope 4 Inpt variables Rated voltage ( : 0 V < < 90 V resp. : 50 V < < 500 V) Rated crrent (0. A < I <.5 A) Rated crrent ( A < I < 7.5 A) Power spply V ACDC 4 V ACDC Otpt modles 50,00 4 mav; binary Interface RS 485 interface + S interface Page 4 of 9
5 PT S Configrable niversal transdcer for all power crrent variables and for mains synchronization EA08.54 E Ordering information Accessories IBISE parameterization software diskette " Connection cable for RS S interface Certificate qality certificate DI (certificate of conformity) qality certificate DI (with test point recording) ZAV ZAV ER 88,00 ** 7,00 ** Deliv. time Special calibration factor Factory parameterization Tag o. (ma. characters) Measring circit Singlephase alternating crrent (~) wire threephase balanced load ( ~ E) wire threephase balanced load with simlated phase ( ~ E) wire threephase nbalanced load ( ~ E) 4wire threephase balanced load ( ~ E) 4wire threephase nbalanced load ( ~ E) Synchronoscope: comparision of two mains voltages with star voltage Synchronoscope: comparision of two mains voltages with delta voltage Inpt variables Crrent direct (0. A < I < 7.5 A) Via crrent transformer: primarysecondary crrent Voltage direct ( : 0 V < < 90 V resp. : 50 V < < 500 V) (clear tet) (clear tet) (clear tet) (clear tet) MS MS MS MS4 MS5 MS6 MS7 MS8 I I ER 86,00 ** Deliv. time Via voltage transformer: primarysecondary voltage Rated freqency 50 Hz 60 Hz 400 Hz (see o. 5) Options other nominal freqency additionally parameterizable 400 Hz (clear tet) F F F4 5 80,00 ** 80,00 ** for measring variables ( o.) Measring variable Measring variable Measring variable voltage crrent active power MainsMains Measring variable reactive power (sinsoidal) Q total (ph.) Q Q Q QP Q Q Q I I I Measring variable reactive power factor (sinsoidal) sinφ total sinφ sinφ sinφ I I I (ph.) BP B B B P total (ph.) P P P Measring variable reactive power (nonsinsoidal) Qn total (ph.) Q Q Q PP P P P P Measring variable active power factor (sinsoidal) cosφtotal cosφ cosφ cosφ (ph.) CP C C C Measring variable reactive power factor (non sinsoidal) QF total (ph.) QF QF QF GP G G G Measring variable active power factor (nonsinsoidal) PFtotal (ph.) DP PF PF PF Measring variable apparent power S total (ph.) S S S D D D SP S S S Measring variable freqency f crrent f crrent f crrent f voltage f voltage f voltage f MainsMains FC FC FC FV FV FV F Measring variable phase angle (sinsoidal) φtotal (ph.) AP φ φ φ φmainsmains A A A A Page 5 of 9
6 PT S Configrable niversal transdcer for all power crrent variables and for mains synchronization EA08.54 E Analog otpt (E0) o. E0 Measred variable A: see page 5 o. Otpt signal (mav) Start E0 A0 ink point E05 A05 Final vale E07 Eample: active power in the threephase system, measring range MW, otpt ma; E0: PP 0 +0 MW 0 +0 ma Analog otpt (E) o. Measred variable A: o. Otpt signal (mav) Eample: voltage Analog otpt (E) E see page 5 Start E A ink point E5 A5 A07 Final vale E7, measring range V, kink point at 50 V, otpt V, kink at V; E: V A7 nit nit Response time ( ms) A09 Response time ( ms) Start ink point Final vale nit Response time o. E E E5 E7 ( ms) Measred variable A: see page 5 o. A A5 A7 A9 Otpt signal (mav) Eample: cosφ total in the threephase system, measring range 0.5 kap ind., otpt ma; E: CP 0.5 kap. 0.5 ind. 4 0 ma Analog otpt 4 (E5) o. Measred variable A4: o. Otpt signal (mav) E5 see page 5 Start E5 A5 Eample: crrent in, measring range A, otpt ma; Binary otpt (E) as plse otpt o. Measred variable A4P: E see page 5 ink point E55 A55 Plse A7 Plses per time nit, ma plsesh) Eample: active power in the phase system, MW, 0 plses MWh; Binary otpt (E4) as alarm otpt o. Measred variable A4G: E4 see page 5 Vale min. E4 Final vale E57 A57 nit E5: I A 4 0 ma Vale E7 nit E: PP 0 MWh Vale ma. E47 o. Response time (ms) A4 Hysteresis (05 %) A47 O contact (AS) C contact (RS) A49 Alarm otpt Eample: crrent, alarm vale ma. at 500 A, response time 500 ms, % hysteresis, C contact E4: MAX 500 A 500 ms % RS Binary otpt A4S as synchronoscope Measred variable A4S: o. E6 Voltage difference () o. Freqency difference () o. Phase angle () o. Alarm vale otpt E7 F E8 F Start E6 E7 E8 Response time (ms) A4 Final vale E67 E77 E87 Hysteresis (05 %) A47 nit nit O contact (AS) C contact (RS) A49 A9 Response time ( ms) Eample: synchronization of two mains: voltage V, freqency...+ Hz, phase angle , response time 500 ms, % hysteresis, O contact operation A4S: 0 +0 V F + Hz A ms % AS A59 Page 6 of 9
7 PT S Configrable niversal transdcer for all power crrent variables and for mains synchronization EA08.54 E Energy conter display Z0 Measred variable Z0: E9 Conter E9 Conter E9 Conter E94 Conter 4 Digit behind dec. point ) Energy direction ) R0 R0 R0 R04 nit Eample : conter display for conter, total active power, digits behind decimal point, energy direction consmption, nit kwh Z0: E9 PP.... consmption kwh Eample : conter display for conter, total reactive power, digit behind decimal point, energy direction indctive, nit kvarh Z0: E9 QP..., ind. kvarh ) allowed settings: ) allowed settings: 0 digits behind decimal point, ma. indication digit behind decimal point, ma. indication digits behind decimal point, ma. indication active power consmption generation reactive power indctive capacity Connection diagrams for srface monting case or analog otpts S Transdcer S A B GD V + : P : : I : Q VT CT MW V A 5 MVar Ma ma ma V. O. E P 8450 F VA V 0005A I ma 4 I V ,5 MADE I GERMAY I 7 9 8! Connection RS 485 interface (optionally) Analog otpt Analog otpt Analog otpt Binary otpt S Inpt crrent Inpt voltage Power spply Terminal RXDTXD A+ RXDTXD B DGD GD Interface connection, 46, analog otpts A B GD S Transdcer S E P V + 5 VA 4 I ma F I V ,5 MADE I GERMAY I 7 9 8! Connection RS 485 interface (optionally) Analog otpt Analog otpt Analog otpt Analog otpt 4 Binary otpt S Inpt crrent Inpt voltage Power spply Terminal RXDTXD A+ RXDTXD B DGD GD Interface connection, 46, Page 7 of 9
8 PT S Configrable niversal transdcer for all power crrent variables and for mains synchronization EA0 8.54E Connection diagram for srface monting case mains synchronization S Transdcer S A B GD V E P 8450 F VA 4 I ma 570 V Connection 5.6 0,5 MADE I GERMAY 8! RS 485 interface (optionally) Analog otpt Analog otpt Analog otpt Binary otpt S Inpt crrent Inpt voltage Power spply Terminal RXDTXD A+ RXDTXD B DGD GD Interface connection 5 4 Dimensional drawings for srface monting case (dimensions in mm) A B GD S Transdcer S : : : : VT CT E P I I I 0, V + 5 VA 4 ma 570 V 5! Page 8 of 9
9 PT S Configrable niversal transdcer for all power crrent variables and for mains synchronization EA08.54 E Connection diagrams for srface monting case Singlephase alternating crrent wire threephase balanced load with simlated phase 5 5 k l ~ v k l ~ k l ~E v k l ~E () V V wire threephase balanced load v w v v V V X X X k l ~E V W wire threephase nbalanced load v w v v V V X X X k l k l ~E V W 4wire threephase balanced load k ~E l v V k ~E l 4wire threephase nbalanced load v w X X X V W k l k l ~E Synchronization of two mains 5 5 () Mains Mains () () Mains Mains () Page 9 of 9
10 ElectronX Haberstrasse 46 D455 Velbert DETSCHAD Tel: Fa: The Company's policy is one of continos prodct improvement and the right is reserved to modify the information contained herein withot notice. Printed in the Fed. Rep. of Germany (0.00) ElectronX 00 ElectronX has Sales & Cstomer Spport
SINEAX P530/Q531 Transducer for active or reactive power
Carrying rai hosing P3/0 resp. P/05 Appication The transdcer (Fig. ) conerts to actie or reactie power of a singe-phase AC or three-phase system with baanced or nbaanced oads. The otpt signa is proportiona
More informationTF 202 / TF 202-Ex. Field mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels
TF 0 / TF 0-Ex Field mounted temperature transmitters, FOUNDATION Fieldbus (H), Pt 00 (RTD), thermocouples, or independent channels 0/-8.69 EN USA Input Resistance thermometer (,, wire circuit) Thermocouples
More informationRequest Ensure that this Instruction Manual is delivered to the end users and the maintenance manager.
Request Ensure that this Instruction Manual is delivered to the end users and the maintenance manager. 1 -A - Introduction - Thank for your purchasing MITSUBISHI ELECTRIC MELPRO TM D Series Digital Protection
More informationMulti-function, economical instrument with 4 functions in the same casing. Accessibility and safety: large-dimension terminals Insulated circuits
200 > Measurement and instrumentation Programmable digital transducers TRIAD 2 range Programmable digital transducers with to 4 analogue outputs Programmable accuracy class PRODUCT ADVANTAGES Up to 4 PROGRAMMABLE
More informationTF 212 / TF 212-Ex. Field mounted temperature transmitters, PROFIBUS PA, Pt 100 (RTD), thermocouples, 1 or 2 independent channels 10/11-8.
TF / TF -Ex Field mounted temperature transmitters, PROFIBUS PA, Pt 00 (RTD), thermocouples, or independent channels 0/-8.70 EN P R O F I PROCESS FIELD BUS B U S Input Resistance thermometer (,, -wire
More informationS95.3U01 / S95.3U11. Head mounted temperature transmitters, programmable, Pt 100 (RTD), thermocouples, electrical isolation
S95.U0 / S95.U Head mounted temperature transmitters, programmable, Pt 00 (RTD), thermocouples, electrical isolation Resistance thermometer (,, wire circuit) Thermocouples Resistance remote signalling
More informationAnalogue Meters CQ2x07 series
Analogue Meters CQ2x07 series Analogue Power Meters Active, reactive, apparent power meters and Power factor meters with exchangeable scales EQ0207/2207/0107/2107 & YQ0207/2207/0107/2107 o Measurement
More informationImpedance relay and protection assemblies
RXZK 21H, 22H, 23H 509 006-BEN Page 1 Issued June 1999 Changed since July 1998 Data subject to change without notice (SE970175) (SE970184) Features Micro-processor based impedance relay with R and X settings
More informationThe Ordering Code for various standard model Recorders with an AC supply and without any additional options are as follows:
The basic PC software is supplied free with the recorder. There is an additional charge for the extensive Data Acquisition Software supplied with communication of RS-232/422/485 or Ethernet. The Ordering
More informationTime - timing relays 1 Industrial relays, solid state output, width 22.5 mm
haracteristics Zelio ime - timing relays Industrial relays, solid state output, width. mm Presentation 08 he E9 range of relays is designed for simple, repetitive applications with short and intensive
More informationType Function Output config. Auxiliary Case Page
Transducers CONTENTS Page Transducer Survey....4 General description and technical data...8 Transducers DU for AC voltage....12 Transducers DI for AC current....16 Transducers DUD for DC voltage and DID
More informationField IT 50T Series Transmitters
Data Sheet SS/G/A_ Field IT 0T Series Transmitters gauge/absolute pressure transmitter Ranges: -00 to 0000kPa - to 00bar -. to 6000psi Base accuracy : 0.% (BFSL) Chemical Vapour Deposition (CVD) technology
More informationS95.3U02 / S95.3U12. Head mounted temperature transmitters, HART programmable, Pt 100 (RTD), thermocouples, electrical isolation
S95.U0 / S95.U Head mounted temperature transmitters, HART programmable, Pt 00 (RTD), thermocouples, electrical isolation Resistance thermometer (,, wire circuit) Thermocouples Resistance remote signalling
More informationDMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm
DMP Pi Precision Pressure Transmitter pressure ports and process connections with flush welded stainless steel diaphragm accuracy according to IEC 600: 0, % FSO Nominal pressure from 0... 00 mbar up to
More information5730A High Performance Multifunction Calibrator. Extended specifications
730A High Performance Multifunction Calibrator Extended specifications General Specifications Warm-Up Time... Twice the time since last warmed up, to a maximum of 30 minutes. System Installation... Rack
More informationRequest Ensure that this Instruction Manual is delivered to the end users and the maintenance manager.
Request Ensure that this Instruction Manual is delivered to the end users and the maintenance manager. 1 -C - Safety section - This Safety section should be read before starting any work on the relay.
More informationEURAX DME 442 Programmable Multi-Transducers
for the measrement of eectrica variabes in heavycrrent power systems Appication The ERAX DME 4 series of mti-transdcers (Fig. 1) simtaneosy measre severa variabes of an eectric power system and process
More informationDMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm
DMP P Industrial Pressure Transmitter Process Connections With Flush Welded Stainless Steel accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 % FSO Nominal pressure from 0... 00 mbar up
More information5SJ4...-.HG Circuit Breakers to IEC and UL 489
Siemens AG 009 5SJ...-.HG Circuit Breakers to IEC and UL 89 BETA Low-Voltage Circuit Protection Compliance with industry standards is a must in today's manufacturing environment. Worldwide acceptance is
More informationOperational Amplifiers
Operational mplifiers lektronikseminar Georg Wirth Institt für Laser Physik rd March 8 Otline Introdction General characteristics Basic operation The ideal op-amp The Concept of Feedback Basic idea of
More informationSINEAX VK 636 Programmable Temperature Transmitter with PROFIBUS-PA protocol
with PROFIBUS-PA procol for installation in the terminal head of a temperature sensor DIN 79, shape B Application 00 II () G FISCO The SINEAX VK 66 is a temperature transducer for use in aumation systems
More informationOperating Instructions for Digital Manometer. Model: MAN-SD
Operating Instructions for Digital Manometer Model: MAN-SD 1. Contents 1. Contents...2 2. Note...3 3. Instrument Inspection...3 4. Regulation Use...4 5. Operating Principle...4 6. Mechanical Connection...5
More informationSimulation investigation of the Z-source NPC inverter
octoral school of energy- and geo-technology Janary 5 20, 2007. Kressaare, Estonia Simlation investigation of the Z-sorce NPC inverter Ryszard Strzelecki, Natalia Strzelecka Gdynia Maritime University,
More informationThermal-Magnetic Circuit Breaker 2210-T2...
Thermal-Magnetic Circuit Breaker 0-T... Description One, two and three pole thermal-magnetic circuit breakers with trip-free mechanism and toggle actuation (S-type TM CBE to EN 6094/IEC 94). Featuring
More informationSINEAX DME 424/442 Programmable multi-transducers
SINEAX DME 424/442 Programmabe mti-transdcers for the measrement of eectrica variabes in heavycrrent power systems Appication The SINEAX DME 4 series of mti-transdcers (Fig. 1) simtaneosy measre severa
More informationDMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor
DMP Industrial Pressure Transmitter for Low Pressure Stainless Steel Sensor accuracy according to IEC 60770: : 0.5 % FSO option: 0.5 / 0. % FSO Nominal pressure from 0... 00 mbar up to 0... 60 bar Output
More informationTH 202 / TH 202-Ex. Field mounted temperature transmitter, HART programmable, Pt 100 (RTD), thermocouples, electrical isolation. ABB Instrumentation
TH 0 / TH 0-Ex Field mounted temperature transmitter, HART programmable, Pt 00 (RTD), thermocouples, electrical isolation 0/-8.6 EN Input Resistance thermometer (,, -wire circuit) Thermocouples Resistance
More information4/4-way servo solenoid directional control valves, directly operated, with electrical position feedback and on-board electronics (OBE)
4/4-way servo solenoid directional control valves, directly operated, with electrical position feedback and on-board electronics (OBE) RE 9035/. Replaces: 05. 1/1 Type 4WRPEH 6 Size 6 Unit series X Maximum
More informationSINEAX DME 424/442 Programmable Multi-Transducers
for the measrement of eectrica variabes in heavycrrent power systems Appication The SIEAX DME 4 series of mti-transdcers (Fig. 1) simtaneosy measre severa variabes of an eectric power system and process
More informationCALYS 80P. Field pressure calibrator with high accuracy 0.01%
Field pressure calibrator with high accuracy 0.01% CALYS 80P is a field pressure calibrator within CALYS range with high accuracy of 0.01%. Description CALYS 80P is a field pressure calibrator within CALYS
More informationNo /06e. Technical Manual Multistage-Temperature-/Differential Controller TAR x700
Technical Manual Multistage-Temperature-/Differential Controller x700 Software Version 0078 o. 5303-0/06e 700 3700 5700 9700 3700 5700 9700 l Suitable as : Multistage Controller or Differential Controller
More informationAUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY HAH1BVW S/08
AUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY HAH1BVW S/08 Introduction The HAH1BVW family is for the electronic measurement of DC, AC or pulsed currents in high power and low voltage automotive applications
More informationDMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm
DMP Pi Precision Pressure Transmitter pressure ports and process connections with flush welded stainless steel diaphragm accuracy according to IEC 600: 0, % FSO Nominal pressure from 0... 00 mbar up to
More informationDS 200P. Electronic Pressure Switch. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm
Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm accuracy according to IEC 600: standard: 0. % FSO option: 0. % FSO Nominal pressure from 0... 00 mbar up to 0... 0 bar
More informationField mounted Temperature Transmitter TF212/TF212-Ex
Data Sheet Field mounted Temperature Transmitter TF/TF-Ex PROFIBUS PA, Pt 00 (RTD), Thermocouples, or independent channels Input Resistance thermometer (,, -wire circuit) Thermocouples Resistance remote
More informationElectric amplifiers. RE 30044/02.12 Replaces: Type VT-VRPA X/V0/RTS-2STV. Component series 2X 1/8
Electric amplifiers RE 30044/02.12 Replaces: 11.02 1/8 Type VT-VRPA1-527-2X/V0/RTS-2STV Component series 2X Table of contents Contents Page Features 1 Ordering code, accessories 2 Front plate 2 Block diagram
More informationNon-Contact Safety Systems CMS
Selection table for non-contact safety system // Evaluation units Connection Desi Read head contact assembly Assured switch-on distance S ao [mm] Assured switch-on distance S ar [mm] Number of outputs
More informationSINEAX VK 626 Programmable Temperature Transmitter for RTD and TC inputs, with HART protocol
SINEAX VK 66 for RTD and TC inputs, with HART procol for installation in the terminal head of a temperature sensor DIN 79, shape B Application II () G SINEAX VK 66 is a two-wire head-mounted transmitter.
More informationWT 27 L-2 Laser Photoelectric proximity switches, background suppression -- DC. Dimensional drawing Adjustments possible WT 27L-2F 430
WT L- Laser Photoelectric proximity switches, background suppression -- DC 00...00 mm Photoelectric proximity switches Dimensional drawing.. Laser LED, red light Adjustable background suppression 0 0.
More information7S SERIES. Relay module with forcibly guided contacts 6 A 7S S /0310 7S
Relay module with forcibly guided contacts.12 with 2 pole (1NO + 1 N).14 with 4 pole (2 NO + 2 N and 3 NO + 1 N).16 with 6 pole (4 NO + 2 N) For safety applications, with class A forcibly guided contact
More informationCALYS 120 IS. ATEX documenting multifunction calibrator with high accuracy 0.006%
ATEX documenting multifunction calibrator with high accuracy 0.006% is the top instrument of our range of ATEX documenting multifunction calibrators. Description is the top instrument of our range of ATEX
More informationCONTENTS. Every day, 365 days a year Cincon makes a difference in people s lives throughout the world.
Every day, 65 days a year Cincon makes a difference in people s lives throghot the world. CONTTS Design engineers and other power spply specifiers select or AC-DC and DC- DC convertors to power a wide
More informationW 30 Photoelectric proximity switches: Clear signals even with low remission
W 0 Photoelectric proximity switches Photoelectric proximity switches, BGS Photoelectric proximity switches, energetic W 0 Photoelectric proximity switches: Clear signals even with low remission In addition,
More informationPascal ET is an handheld multifunction calibrator for the measurement and simulation of the following parameters: - pressure
DATASHEET Pascal ET Pascal ET is an handheld multifunction calibrator for the measurement and simulation of the following parameters: - pressure - electrical signals (ma, mv, V, ) - temperature (TC and
More informationDimensional drawing face mount flange radial. R = bending radius min. 40 mm. Dimensional drawing face mount flange axial
Incremental Encoder DRS/DRS, face mount flange up to 8,2 Dimensional drawing face mount flange radial Incremental Encoder Connector or cable outlet Protection class up to IP s TTL and HTL Zero-Pulse-Teach
More informationTHM80X Series Feature Application. Temperature & Humidity / Flow Measuring Specialist
THM80X Series Feature Application IP67 protection degree, rugged aluminum case, fit in variety harsh environment Capable of temperature compensation Linear adjustment temperature & humidity by computer,
More information792A AC/DC Transfer Standard
92A AC/DC Transfer Standard Technical Data Support for your most demanding ac measurement requirements ppm total uncertainty Traceable to national standards range: 2 mv to 00 V Frequency range: Hz to 1
More information792A AC/DC Transfer Standard
92A AC/DC Transfer Standard Technical Data Support for your most demanding ac measurement requirements ppm total uncertainty Traceable to national standards range: 2 mv to 00 V Frequency range: Hz to 1
More informationIJSER. =η (3) = 1 INTRODUCTION DESCRIPTION OF THE DRIVE
International Jornal of Scientific & Engineering Research, Volme 5, Isse 4, April-014 8 Low Cost Speed Sensor less PWM Inverter Fed Intion Motor Drive C.Saravanan 1, Dr.M.A.Panneerselvam Sr.Assistant Professor
More informationTB2. Data Sheet. Torque reference transducer. Special features. B en
T2 Torque reference transducer Data heet pecial features tandard version ptional: rotection I67 - ccuracy class 0.03 - s 100 m, 200 m, 500 m, 1 k m, 2 k m, 3 k m, 5 k m and 10 k m - High permissible oscillation
More informationAC axial compact fan
ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-767 Mulfingen Phone +9 798 8-0 Fax +9 798 8-0 info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen Amtsgericht (court of registration)
More informationHYGRASGARD KFF KFTF HYGRASGARD AFF AFTF HYGRASGARD AFF - LC AFTF - LC
HYGRASGARD AFF - LC AFTF - LC sensors, calibrateable, with and active passive output Quality product for HVAC sector, accuracy % r.h. The calibrateable room humidity and temperature sensor HYGRASGARD KFF
More informationAC axial compact fan
ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-7467 Mulfingen Phone +49 798 8-0 Fax +49 798 8-0 info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen County court Stuttgart HRA
More informationDigital Current Transducer HO-SW series I P N = A. Ref: HO 100-SW; HO 150-SW; HO 200-SW; HO 250-SW
Digital Current Transducer HO-SW series I P N = 100... 250 A Ref: HO 100-SW; HO 150-SW; HO 200-SW; HO 250-SW Bitstream output from on onboard Sigma Delta modulator. For the electronic measurement of current:
More informationOnline data sheet WL280-S230 W280 COMPACT PHOTOELECTRIC SENSORS
Online data sheet WL80-S30 W80 WL80-S30 W80 A B C D E F Illustration may differ Ordering information Type Part no. WL80-S30 607484 Included in delivery: P0 (), BEF-W80 () Other models and accessories www.sick.com/w80
More informationSiemens AG Miniature Circuit Breakers. Totally Integrated Power SENTRON. Configuration. Edition 10/2014. Manual. siemens.
Siemens AG 05 Totally Integrated Power SENTRON Configuration Manual Edition 0/0 siemens.com/lowvoltage Siemens AG 05 Siemens AG 05 Introduction 5SL miniature circuit breakers 5SY and 5SP miniature circuit
More informationTYPE. max. working voltage 250 V 350 V 500 V 750 V. max. overload voltage 500 V 700 V 1000 V 1500 V. basic specifications IEC B
FEATURES Non inductive High pulse loading capability. APPLICATIONS Application for overload and high voltage surge hazard circuits. DESCRIPTION A carbon film is deposited on a high grade ceramic body.
More informationFor the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.
Current Transducer HO-NP series I P N = 4, 6, 12, 15 A Ref: HO 4-NP, HO 6-NP, HO 12-NP, HO 15-NP For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary
More informationTo order, specify : Types Protection functions Current surge Asymmetry and loss of phase. Operating principle
otor protection relays - T - FWIT Since % of -phase motor failures are due to load problems or loss of phase, the CROUZET range of motor protection relays is indispensable! models give motor protection
More informationA TWO-STAGE INDUCTIVE VOLTAGE DIVIDER FOR COAXIAL BRIDGES
A TWO-STAGE IDUTIVE VOLTAGE DIVIDER FOR OAIAL BRIDGES G. A. Kyriazis, J. A. Moreno, J. Melcher 3 Inmetro, Dqe de axias, Brazil, gakyriazis@inmetro.gov.br EAM, Qerétaro, Mexico, jmoreno@cenam.mx 3 PTB,
More informationFL ballasts Electronic fixed output. PC TC PRO sr 1/2x11 42 W PC PRO compact
FL ballasts EL HE PC TC PRO sr 1/2x11 42 W PC PRO compact Product description CELMA Energy Efficiency Index A2 BAT / A2 T Nominal life-time up to 50,000 h (at ta 50 C with a failure rate max. 0.2 % per
More informationThermal-Magnetic Circuit Breaker 2210-S2..
Thermal-Magnetic Circuit Breaker -S.. Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 6094/IEC 94). Designed for
More informationAC axial compact fan
ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-767 Mulfingen Phone +9 798 8- Fax +9 798 8- info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen County court Stuttgart HRA 59
More informationThermal-Magnetic Circuit Breaker 2210-S2...
Thermal-Magnetic Circuit Breaker 0-S... Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 60934/IEC 934). Designed
More informationThermal-Magnetic Circuit Breaker 2210-S2...
Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 6094/IEC 94). Designed for panel or plug-in mounting. Available
More informationINFORMATION TECHNOLOGY SYSTEMS SPDs FOR 19 TECHNOLOGY. NET Protector Surge Arrester. Protects switches, HUBs and telecommunication
Surge Arrester Protects switches, HUBs and telecommunication systems Class D according to EN 0 possible (Gigabit Ethernet) Variably equippable patch panels Units available with plug-in inputs and outputs
More informationDesigning of Virtual Experiments for the Physics Class
Designing of Virtal Experiments for the Physics Class Marin Oprea, Cristina Miron Faclty of Physics, University of Bcharest, Bcharest-Magrele, Romania E-mail: opreamarin2007@yahoo.com Abstract Physics
More informationSingle cam type. Double cam type. Grip force N. Type Model/size Stroke Screw type straight style. Screw type tee style
Type Model/size Stroke -SS-0-N. -SS-0-N. Single cam type -SS- 7. -SS-. -SS-4. -SD-0 Double cam type -SD- -SD-4. Screw type straight style Screw type tee style -FS- -FT- -FS- -FT- 0.9 1. 1.. 1. 4 Grip forcen
More information5SP and 5SY Supplementary Protection UL 1077
Product Guide 5SP and 5SY Supplementary Protection UL 077 for North merican and International applications usa.siemens.com/5sy Table of contents Certifications, standards, features and description Characteristic
More informationBETA Protecting Miniature Circuit Breakers
Siemens AG 00 / Product overview / High-capacity range 000 A 0000 A 0000 A, high current 0000 A, universal current 000 A ka /0 Comfort range with plug-in terminal / Compact range +N in MW / Additional
More informationAnalog - Digital multimeters
CAT-IV -3, MI, Satpur, Nashik-4 7,India. Tel.: +9 53 6, ax : +9 53 3564 Page of / 5 / I I / 7 / B Automatic Terminal Blocking System (ABS) The automatic Terminal blocking system prevents incorrect connection
More informationWEAR PREDICTION OF A TOTAL KNEE PROSTHESIS TIBIAL TRAY
APPLIED PHYSICS MEDICAL WEAR PREDICTION OF A TOTAL KNEE PROSTHESIS TIBIAL TRAY L. CÃPITANU, A. IAROVICI, J. ONIªORU Institte of Solid Mechanics, Romanian Academy, Constantin Mille 5, Bcharest Received
More informationOverload Relays. SIRIUS 3RU1 Thermal Overload Relays. 3RU11 for standard applications. 5/46 Siemens LV 1 AO 2011
SIRIUS 3RU1 Thermal Overview 1 2 7 3 4 6 "Increased safety" type of EEx e according to ATEX directive 94/9/EC The 3RU11 thermal overload relays are suitable for the overload of explosion-proof motors with
More informationBTE5000 / PTE5000 / PTU5000 Series Precision differential pressure transmitters
FEATURES 5 mbar to 0 bar, 0. to 50 psi differential pressure...6 or...0 ma Precision temperature compensated and calibrated Rugged aluminium housing Female /8" BSP and /8" NPT fittings MEDIA COMPATIBILITY
More informationAC axial fan. Limited partnership Headquarters Mulfingen Amtsgericht (court of registration) Stuttgart HRA
ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-767 Mulfingen Phone +9 798 8- Fax +9 798 8- info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen Amtsgericht (court of registration)
More informationPM150RSA060 Intellimod Module Three Phase + Brake IGBT Inverter Output 150 Amperes/600 Volts
N Powerex, Inc., 2 Hillis Street, Youngwood, Pennsylvania 15697-18 (724) 925-7272 Three Phase + Brake IGBT Inverter Output AD R AB A B AB Q Y (4 TYP.) S G H N M M AG AE AG Outline Drawing and Circuit Diagram
More informationTCET110.(G) up to TCET4100. Optocoupler with Phototransistor Output. Vishay Telefunken. Description. Applications. VDE Standards
Optocoupler with Phototransistor Output Description The TCET11./ TCET2/ TCET4 consists of a phototransistor optically coupled to a gallium arsenide infrared-emitting diode in a 4-lead up to 16-lead plastic
More informationBMXART0814 analog input module M340-8 inputs - temperature
Product data sheet Characteristics BMXART0814 analog input module M340-8 inputs - temperature Main Range of product Product or component type Electrical connection Input output isolation Input level Analogue
More informationBMXART0814 analog input module M340-8 inputs - temperature
Characteristics analog input module M340-8 inputs - temperature Complementary Analog/Digital conversion Analogue input resolution Input impedance Permitted overload on inputs Common mode rejection Differential
More informationChapter 3 MATHEMATICAL MODELING OF DYNAMIC SYSTEMS
Chapter 3 MATHEMATICAL MODELING OF DYNAMIC SYSTEMS 3. System Modeling Mathematical Modeling In designing control systems we mst be able to model engineered system dynamics. The model of a dynamic system
More informationSEN TRONIC AG 1 A 6 6 / "
1A 66/" 0!"#$%&'() %"*+", - %"*.", - /01234%( 34.+*!54%& 0*%/# "6#,7857.'.0" - 6#)9.:. &%&;! 0 &????'.&% )&" 8" @&& (++ '() %('.('/(#$!!! ' %! %!& ;!;8 ;!;8 0 &&'&&;! C;!C&(D"@@ &;! 0&&+%&;! C&=;!C&(D"@@
More informationCPU DESIGN The Single-Cycle Implementation
22 ompter Organization Seqential vs. ombinational ircits Digital circits can be classified into two categories: DESIGN The Single-ycle Implementation. ombinational ircits: m, 2. Seqential ircits: flip-flops,
More informationCapaciTorr HV 200 HIGHLIGHTS
CapaciTorr HV 200 General Features High pumping speed for all active gases High sorption capacity and increased lifetime Costant pumping speed in HV, UHV and XHV Reversible pumping of hydrogen and its
More informationfor the measurement of electrical variables in heavycurrent Application Features / Benefits
SIEAX DME 440 with RS SIEAX 485 interface DME 440 with RS 485 interface for the measrement of eectrica variabes in heavycrrent power system Appication SIEAX DME 440 (Fig. 1) is a programmabe transdcer
More informationW 34: Sensor technology that does justice to demanding requirements
KD0_W_en.qxd.0.00 : Uhr Seite W Photoelectric switches Photoelectric proximity switches BGS Photoelectric reflex switches Through-beam photoelectric switches W : Sensor technology that does justice to
More informationClassify by number of ports and examine the possible structures that result. Using only one-port elements, no more than two elements can be assembled.
Jnction elements in network models. Classify by nmber of ports and examine the possible strctres that reslt. Using only one-port elements, no more than two elements can be assembled. Combining two two-ports
More informationCNY17 Series. Optocoupler with Phototransistor Output. Vishay Telefunken. Description. Applications. VDE Standards.
Optocoupler with Phototransistor Output Description The CNY7 series consists of a phototransistor optically coupled to a gallium arsenide infrared-emitting diode in a 6-lead plastic dual inline package.
More informationThermal-Magnetic Circuit Breaker 2210-S2..
Thermal-Magnetic Circuit Breaker -S.. Description One, two and three pole thermal-magnetic circuit breakers with trip-free mechanism and toggle actuation (S-type TM CBE to EN 60934/IEC 934). Designed for
More informationAUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY HC6H 400-S/SP1
AUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY HC6H 400-S/SP1 Picture of product with pencil Introduction The HC6H family is for the electronic measurement of DC, AC or pulsed currents in high power
More informationUncertainties of measurement
Uncertainties of measrement Laboratory tas A temperatre sensor is connected as a voltage divider according to the schematic diagram on Fig.. The temperatre sensor is a thermistor type B5764K [] with nominal
More informationAIR PREPARATION. ELECTRONICALLY CONTROLLED PRESSURE REGULATING VALVE (PROPORTIONAL PRESSURE REGULATING VALVE) SERIES control
AIR PREPARATION ELECTRONICALLY CONTROLLED PRESSRE REGLATING ALE (PROPORTIONAL PRESSRE REGLATING ALE) SERIES control Description Abb. Port size Recommended Type Data Sheet No. flow (l/min)* airfit tecno
More informationCNY17F-4. Pb Pb-free. Optocoupler, Phototransistor Output, No Base Connection. Vishay Semiconductors
Optocoupler, Phototransistor Output, No Base Connection Features Breakdown Voltage, 500 V RMS No Base Terminal Connection for Improved Common Mode Interface Immunity Long Term Stability Industry Standard
More informationThermal-Magnetic Circuit Breaker 2210-S2..
Thermal-Magnetic Circuit Breaker -S.. Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 60934/IEC 934). Designed for
More informationT20WN. Data Sheet. Torque transducers. Special features. Installation example with bellows couplings. B en
T20WN Torque transducers Data Sheet Special features - Nominal (rated) torques 0.1 N m, 0.2 N m, 0. N m, 1 N m, 2 N m, N m, 10 N m, 20 N m, 0 N m, 100 N m, 200 N m - Accuracy class: 0.2 - Contactless transmission
More informationCosmic Microwave Background Radiation. Carl W. Akerlof April 7, 2013
Cosmic Microwave Backgrond Radiation Carl W. Akerlof April 7, 013 Notes: Dry ice sblimation temperatre: Isopropyl alcohol freezing point: LNA operating voltage: 194.65 K 184.65 K 18.0 v he terrestrial
More informationTCLT10.. Series. Optocoupler with Phototransistor Output. Vishay Semiconductors. Description. Applications. VDE Standards
Optocoupler with Phototransistor Output Description The TCLT1.. Series consists of a phototransistor optically coupled to a gallium arsenide infraredemitting diode in a 4-lead SO6L package. The elements
More informationSealing possibility Electrical endurance (ops) Mechanical endurance (ops) Overvoltage category Standards
Miniature circuit breaker ETIMAT 7,7 0.5 Rated voltage Rated current Rated frequency Rated short-circuit capacity Energy limiting class characteristic Build-in width Mounting on the rail 0/00 V AC, max.
More informationED 701 General Industry Pressure Transmitter
ED 701 General Industry Pressure Transmitter Standard industrial process connections Complete range of electrical connections 4... 20 ma and Voltage outputs Accuracy: 0.1%, 0.2% and 0.4% FS Quick response
More informationZ7A. Load cells. Special features. Data sheet. Wiring code
Z7A Load cells Special features - Complies with OIML R60 regulations up to 3000 d - Max. capacities: 500 kg... 10 t - Fulfills EMC requirements in accordance to EN 45 501 - Low transducer height - Robust
More informationE6C-N. Ideal for Out-of-step Detection of Stepping Motors and Position Control of Rotors and Unloaders
Multi-turn High-precision Encoder Ideal for Out-of-step Detection of Stepping Motors and Position Control of Rotors and Unloaders Reset function for easy origin alignment when built-into equipment. Multi-turn
More information