1 MAKING MOERN IVING POSSIBE ata sheet igh pressure sight glass (PS = 2 bar) Types SGP N, SGP I and SGP X Sight glasses are used to indicate:. The condition of the refrigerant in the liquid line of the plant. 2. The flow in the oil return line from the oil separator.. The moisture content in the refrigerant. The SGP X are mainly used to indicate the condition of the refrigerant as well as the liquid level in the receiver or the oil level in the compressor. The SGP N and SGP I are equipped with sensitive indicators that reflects a colour, depending on the moisture content in the refrigerant. Features Type SGP X (without indicator) y Indicates lack of subcooling y Indicates refrigerant deficiency y Indicates liquid level in receiver y Indicates oil level in compressor y Flare-/solder connection or socket type Type SGP I (with I type indicator) y For CFC and C refrigerants y Indicates too high moisture content in the refrigeration system y Indicates lack of subcooling y Indicates refrigerant deficiency y Flare-/solder connection or socket type Type SGP N (with N type indicator) y For CFC, FC, C and R44 refrigerants y Indicates too high moisture content in the refrigeration system y Indicates lack of subcooling y Indicates refrigerant deficiency y Flare-/solder connection or socket type KRCC.P.EK anfoss A/S (RC-MP/sw),
2 igh pressure sight glass, type SGP N, SGP I and SGP X Technical data Ambient temperature -0 C 80 C Max. working pressure PS/MWP = 2 bar Available types Solder version SGP X Without moisture indicator Socket SGP RX Socket type without moisture indicator Flare version Solder version SGP I For CFC and C SGP RI For Refrigerant with mineral oil e.g. CFC Flare version SGP N For CFC, FC, C and R44 (CO 2 ) Socket SGP RN For non-flammable FC Choice of sight glass Before choosing a sight glass with moisture indicator, the following should be considered: y type of refrigerant y water solubility of refrigerant y the level on which a danger signal is required. Be aware that polyester oil for refrigerants like, e.g. R4a, R404A, R40C react with water in a hydrolysis generating acid and alcohol. The recommended levels of moisture content are usually between 0 and ppm, where hermetic compressors only tolerate very low moisture content, while semi-hermetic and other compressors normally tolerate higher moisture contents in the refrigerant. The on the sight glass indicator depends on the moisture content of the refrigerant. The values under green/ are to be considered as perfect condition meaning full protection against harmful effects from moisture. In other words, the filter drier is working perfectly. If the green starts to fade, the change has begun and the indicator should therefore be watched more carefully. If the changes to yellow it is a clear signal, that the capacity of the filter drier is exceeded and should be replaced as soon as possible. SGP I for CFC and C SGP N for CFC, FC, C and R44 (CO 2 ) Moisture content ppm = parts per million SGP N / SGP RN 2 C 4 C Moisture content ppm = parts per million SGP I / SGP RI 2 C 4 C R22 < > 20 < > 200 R2 < > 00 < >00 R4a < > 00 < >0 R404A < > 0 < >00 R40C < > 40 < >22 R0 < 60 > 60 < >0 R40A < > 266 < 40 > 40 R20 < > 62 < > Note: For moisture values of other refrigerants, like R44, pls contact anfoss. R22 < >00 < > 00 R290 < >0 < > 00 R600 < > 20 < > R600a < 22 >22 < > 60 2 KRCC.P.EK anfoss A/S (RC-MP/sw),
3 Ordering igh pressure sight glass, type SGP N, SGP I and SGP X Without Indicator Type Version Connection [in.] Connection [mm] Code no. SGP 0 X Flare ext. ext SGP 2s X SGP 6s X OF OF solder I type indicator for CFC and C SGP 6 I SGP 0 I SGP 2 I SGP 6 I SGP 9 I SGP 6 I SGP 0 I SGP 2 I SGP 6 I SGP 9 I SGP 6s I SGP 0s I SGP 2s I SGP 6s I SGP 9s I SGP 22s I SGP 6s I SGP 0s I SGP 2s I SGP 8s I SGP 6s I SGP 0s I SGP 2s I SGP 6s I SGP 22s I Flare ext. ext. Flare int. ext. ) OF OF solder ) Can be screwed directly into the filter drier. 2) Oversize anfoss A/S (RC-MP/sw), KRCC.P.EK OF OF solder OF OM solder N type indicator for CFC, FC, C and R44 (CO 2 ) SGP 6 N SGP 0 N SGP 2 N SGP 6 N SGP 9 N SGP 6 N SGP 0 N SGP 2 N SGP 6 N SGP 9 N SGP 6s N SGP 0s N SGP 2s N SGP 6s N SGP 9s N SGP 22s N SGP 22s N 2 ) SGP 6s N SGP 0s N SGP 2s N SGP 8s N SGP 6s N SGP 0s N SGP 2s N SGP 6s N SGP 22s N Flare ext. ext. Flare int. ext. ) OF OF solder OF OF solder OF OM solder
4 Ordering (continued) igh pressure sight glass, type SGP N, SGP I and SGP X Socket type Type Version Connection 2 Code no. SGP ¾ RX SGP ¾ RX SGP ½ RX Pipe thread G ¾ A ) ¾ -4 2) ½ -4 2) SGP ½ RI SGP 24 RI M thread ½ - 4 2) M SGP ½ RN SGP 24 RN M thread ½ -4 2) M M24 M24 M24 M24 M24 M24 M SGP 20 RN M thread M M ) ISO 228-2) ANSI/ASME B KRCC.P.EK anfoss A/S (RC-MP/sw),
5 igh pressure sight glass, type SGP N, SGP I and SGP X imensions [mm] and weights [kg] B B SGP flare, int. ext. SGP solder OF OF B B SGP flare, ext. ext. SGP solder OF OM Type Version B ø Net weight SGP 6 N, SGP 6 I SGP 0 N, SGP 0 I SGP 2 N, SGP 2 I Flare ext. ext SGP 6 N, SGP 6 I SGP 9 N, SGP 9I SGP 6 N, SGP 6 I SGP 0 N, SGP 0 I SGP 2 N, SGP 2 I Flare int. ext SGP 6 N, SGP 6 I SGP 9 N, SGP 9 I SGP 6s N, SGP 6s I SGP 0s N, SGP 0s I SGP 2s N, SGP 2s I SGP 6s N, SGP 6s I Solder SGP 8s N, SGP 8s I OF OF SGP 9s N, SGP 9s I SGP 22s N, SGP 22s I SGP 22s N, SGP 22s I oversize SGP 6s N, SGP 6s I SGP 0s N, SGP 0s I SGP 2s N, SGP 2s I Solder OF OM SGP 6s N, SGP 6S I SGP 22s N, SGP 22s I anfoss A/S (RC-MP/sw), KRCC.P.EK
6 igh pressure sight glass, type SGP N, SGP I and SGP X imensions [mm] and weights [kg] B B SGP RX socket SGP RN / SGP RI socket Type Version B ø Net weight SGP ½ RX Socket, SGP ¾ RX Socket, G / SGP ¾ RX Socket, SGP ½ RN, SGP ½ RI Socket, SGP RI, M24* Socket, Metric KRCC.P.EK anfoss A/S (RC-MP/sw),
Eliminator Liquid line filter driers, Type DCL and DML
MAKING MODERN LIVING POSSIBLE Eliminator Liquid line filter driers, Type DCL and DML Flare connection Solder connection (copper) REFRIGERATION & AIR CONDITIONING DIVISION Technical leaflet Contents Page
More informationUni-Flow Filter Drier
STNDRD Uni-Flow Filter Drier The filter driers of series DTG are used in refrigeration system with unidirectional flow to absorb moisture and acid in the system and to filter out the impurities. FETURES
More informationSolenoid valve Types CSV 2 - CSV 22 (NC) and solenoid coil
Data sheet Solenoid valve s CSV 2 - CSV 22 (NC) and solenoid coil CSV is a direct or servo-operated solenoid valve for liquid, suction, and hot gas lines with fluorinated refrigerants. CSV valves are for
More informationSolenoid valves Type EVUL
Data sheet Solenoid valves EVUL EVUL solenoid valves are designed to fit into compact refrigeration systems. Available in servo operated versions they can be applied in liquid, suction, and hot gas lines.
More informationSight Glass and Moisture Indicator Virginia KMP Series LDE
Sight Glass and Moisture Indicator Virginia KMP LDE DIMENSIONS: Dimension Dimension Connection Type "A" "B" Inches (mm) Inches (mm) LDE2 1/4 Male X 1/4 Male 2-7/8 72 1-7/ 36 LDE2S 1/4 Sweat X 1/4 Sweat
More informationMAKING MODERN LIVING POSSIBLE. Thermostatic expansion valve Type TUB/TUBE and TUC/TUCE REFRIGERATION AND AIR CONDITIONING.
MAKING MODERN LIVING POSSIBLE Thermostatic expansion valve Type B/BE and C/CE REFRIGERATION AND AIR CONDITIONING Technical leaflet Thermostatic expansion valve, type B/BE and C/CE Contents Page Introduction........................................................................................
More informationThermostatic expansion valves TUA/TUAE
MAKING MODERN LIVING POSSIBLE Technical brochure Thermostatic expansion valves A/AE www.danfoss.com Thermostatic expansion valves, type A/AE Contents Page Introduction... Features... Standard range...
More informationSolenoid valves Type EVR 2 g 40 NC/ NO New EVR 6 with Steel cover design
MAKING MODERN LIVING POSSIBLE Technical brochure Solenoid valves EVR 2 g 40 NC/ NO New with Steel cover design EVR is a direct or servo operated solenoid valve for liquid, suction, and hot gas lines with
More informationThermostatic expansion valves TUB/TUBE and TUC/TUCE
MAKING MODERN LIVING POSSIBLE Technical brochure Thermostatic expansion valves B/BE and C/CE www.danfoss.com Thermostatic expansion valve, type B/BE and C/CE Contents Page Introduction........................................................................................
More informationAIR CONDITIONING COMMERCIAL REFRIGERATION HEAT PUMP STANDARD PRODUCT CATALOGUE
AIR CONDITIONING COMMERCIAL REFRIGERATION HEAT PUMP STANDARD PRODUCT CATALOGUE CA-STD- SUMMARY SANHUA Strive for perfection, Pursuit of excellence 4 WAY REVERSING VALVE SHF SERIES 4 WAY REVERSING VALVE
More informationHIGH POWER THICK FILM CHIP FIXED RESISTOR
HIGH POWER THICK FI CHIP FIXED RESISTOR 2W High power up to 2W Current detecting resistors for power supply, motor circuits ROHS Compliant with RoHS directive etc Halogen free requirement Switching Power
More informationAIR COOLED CONDENSING UNIT
NEW EVOLUTION SERIES AIR COOLED CONDENSING UNIT OUTDOOR AIR COOLED CONDENSING UNIT ORIGINAL MANUFACTURED EQUIPMENT NEW EVOLUTION 7 & 8 SERIES BA-506-5 AUS Evolution Air Cooled Condensing Unit Series Content
More informationModular Style Air Combination. Assembled by simply tightening the screws
Modular Style Air Combination Series AC Assembled by simply tightening the screws High strength die cast bracket Drain cock for one push drain exhaust Oil needle for easy oil volume adjustments The improved
More informationAIR CONDITIONING STANDARD COMMERCIAL REFRIGERATION HEAT PUMP PRODUCT CATALOGUE
AIR CONDITIONING COMMERCIAL REFRIGERATION HEAT PUMP STANDARD PRODUCT CATALOGUE CA-STD-EN-R1013 SUMMARY SANHUA Strive for perfection, Pursuit of excellence 04 4 WAY REVERSING VALVE SHF SERIES 08 4 WAY
More information/2 way valves (solenoid actuated diaphragm with forced lifting) 1/4... 2
/ way valves (solenoid actuated diaphragm with forced lifting) /4... Damped operation Operation without differential Suitable for vacuum igh flow rate For systems with low or fluctuating Brass body Wide
More informationBrushless DC Variable Speed Compressor Technical Data Sheet
R134a V DC VARIABLE SPEED Brushless DC Variable Speed Compressor Technical Data Sheet General Information Compressor Part Number (Stationary) CASCADE0005 (140 per pallet) Compressor Part Number (Mobile)
More informationBrushless DC Variable Speed Compressor Technical Data Sheet
R134a V DC VARIABLE SPEED Brushless DC Variable Speed Compressor Technical Data Sheet General Information Compressor Part Number (Stationary) CASCADE0006 (140 per pallet) Compressor Part Number (Mobile)
More information4 Way Reversing Valve
STANDARD 4 Way Reversing Valve SHF series four-way reversing valves are applicable for heat pump systems such as central, unitary and room air conditioners to realize switching between cooling mode and
More informationOdor Removal Filter Series AMF
Odor Removal Filter Series AMF Series AMF Odor Removal Filter efficiently removes odor in compressed air with an activated carbon element. The unit is designed for use in food processing, pharmaceutical,
More informationHD 049 HD 069 HD 172 HD 319 HD 419 HD 619. Operating pressure up to 8700 psi Nominal flow rate up to gpm us
H i g h P re s s u re i l t e r K i t s H 049 H 069 H 172 H 319 H 419 H 619 Operating pressure up to 8700 psi Nominal flow rate up to 118.9 gpm 40.95-3us e s c r i p t i o n pplication In the high pressure
More informationAccumulators Virginia KMP Suction Line Accumulators
Accumulators Virginia KMP Suction Line Accumulators The Virginia KMP suction line accumulator's purpose is to prevent excessive quantities of liquid refrigerant and oil from returning to the compressor.
More informationAME Model. (1) Rated flow (l/min (ANR)) Port size (Nominal size B) Weight (kg)
Super Mist Separator Series AME Series AME separates and absorbs aerosol state fine oil particles in compressed air and changes the oil lubricating compressed air to oilless equivalent air. It should be
More informationOUTDOOR UNITS. Introduction YMF-C. Introduction. Refrigerant
Introduction Introduction Refrigerant R407C R Series Y series (Heat Pump) R series (Air-cooling) Y series ( Only) Y series (Heat Pump) R series (Air-cooling) Y series ( Only) OUTDOOR UNITS Model Name -YMF-C
More informationCooler-Bypass Thermostat Valve, Size 10
Cooler-Bypass Thermostat Valve, Size Q max = l/min, p max = bar Temperature-controlled, integral relief function Description These direct acting bypass thermostat valves are size, temperature controlled,
More informationUsing special passivation material, and has good moisture resistance, corrosion resistance, high reliability.
-TH HIGH STILITY THIN FILM HIP FIXED RESISTOR - TH SERIES Features ( 0.0%; ppm/ ) Low TR and high accuracy( 0.0%; ppm/ ) Suit for re-flow and wave soldering With good sufuration-resistant perfornance ROHS
More informationCooling Water Flow Regulator
Temperature controlled, indirectly and directly actuated diaphragm valves / seat valves Port size G 3/8 to G DN 0 to DN 0 ontinuous regulation High accuracy No auxiliary energy required Technical data
More informationDirect-operated 2/2-way solenoid valves Type EV210B
Data sheet Direct-operated 2/2-way solenoid valves Type EV20B EV20B covers a wide range of direct-operated 2/2-way solenoid valves for universal use. EV20B is a very robust valve program with high performance
More informationSolenoid valve Types EVR 2 - EVR 40
Data sheet Solenoid valve s EVR 2 - EVR 40 EVR is a direct or servo operated solenoid valve for liquid, suction, and hot gas lines with HCFC and HFC refrigerants. EVR valves are supplied complete or as
More informationZHEJIANG FOTECH INTERNATIONAL CO., LTD.
Company Profile Zhejiang Fotech International Co., Ltd is a leading manufacturer and supplier of Refrigerant Gases, Fluor Polymer and Fluor Rubber. Products that are inventoried include:r22, R32, R134A,
More informationE 094 E 103 E 143. Tank top mounting Connection up to G1 Nominal flow rate up to 135 l/min e
R e t u r n F i l t e rs E 094 E 103 E 143 Tank top mounting Connection up to G1 Nominal flow rate up to 135 l/min 20.30-5e D e s c r i p t i o n Application In the return line circuits of hydraulic systems.
More informationED 701 General Industry Pressure Transmitter
ED 701 General Industry Pressure Transmitter Standard industrial process connections Complete range of electrical connections 4... 20 ma and Voltage outputs Accuracy: 0.1%, 0.2% and 0.4% FS Quick response
More informationAIR CONDITIONER (SPLIT TYPE) SERVICE MANUAL
AIR CONDITIONER (SPLIT TYPE) SERVICE MANUAL FILE No. A10-023-1 REVISION 1 : Mar.2012 Re-edit version.( file volume down) Contents have NOT been changed. Model name: RAS-M10PKVP-E RAS-M13PKVP-E RAS-M16PKVP-E
More informationAIR COOLED CONDENSING UNIT
EVOLUTION SERIES AIR COOLED CONDENSING UNIT OUTDOOR AIR COOLED CONDENSING UNIT ORIGINAL MANUFACTURED EQUIPMENT Evolution Series BA-503-3 AUS Evolution Air Cooled Condensing Unit Series Content Page Explanation
More informationI nllk 08018/18 I nllk I nllk 08036/36 I nllk I I nllk 08058/58 I
I nllk / I x W x W x W x W x W Technical data Cooper Crouse-Hinds - all rights reserved nllk / nllk nllk / nllk nllk / Marking to //EC II G Ex na II T / II D td A IP T C EC Conformity Statement PTB ATEX
More informationDirect-operated 2/2-way compact solenoid valves Type EV210A
Data sheet Direct-operated 2/2-way compact solenoid valves Type EV210A EV210A covers a wide range of small, directoperated 2/2-way solenoid valves for use in industrial machinery. The compact design together
More informationPlate heat exchangers DV285 series, type E
REGULUS spol. s r.o. tel.: +420 241 764 506 Do Koutů 1897/3 +420 241 762 726 143 00 Praha 4 fax: +420 241 763 976 CZECH REPUBLIC www.regulus.eu e-mail: sales@regulus.cz Plate heat exchangers DV285 series,
More informationATEX/IECEx RTD temperature probe
Page 1/8 ATEX/IECEx RTD temperature probe with connecting cable acc. to DIN EN 60751 For temperatures from -100 to +600 C As single, double, or triple RTD temperature probe In two-wire, three-wire, or
More informationZF Series Force Transducers
Data Sheet Series Force Transducers FEATURES 1 kn to 00 kn High accuracy For tensile or pressure forces Made of stainless steel Enclosure protection IP 67 DESCRIPTION The force transducers of the series
More informationInverter Multi-Split System
Inverter MultiSplit System Specifications Inverter MultiSplit Fan coil unit Fan Coil Unit Model RAVMS3KCVT RAVMS3KCVT RASMS3KCVT RAVM22S3KCVT RAVM24S3KCVT Standard Cooling Capacity (btu/hr) 9,212 12,624
More informationPRO-CLEAN STRATIFIED TANK
PO-CLEAN STATIFIED TANK PODUCT DESCIPTION Pro-Clean stratified tank with spherical exchanger connection High-quality, multifunctional stratified tank made of steel (S J) for hot-water operation and domestic
More informationMaximum pressure 420 bar Flow rate to 152 l/min. 560 bar. 140 l/min. Flow rate l/min FMM 050 1/2 1,50 3/4 1,00. Δp bar 0,50 0,00 FHA 051 1,50 1,00
FMM 00 Maximum pressure 0 bar Flow rate to l/min FHA 0 Maximum pressure 60 bar Flow rate to 0 l/min Technical data FMM 00 Filter housing (Materials) Head: Cast iron (chemical heat treatment) Housing: Steel
More informationSolenoid valves 2/2-way direct-operated type EV210A
MAKING MODERN LIVING POSSIBLE Data sheet Solenoid valves 2/2-way direct-operated type EV210A EV210A covers a wide range of small, direct-operated 2/2-way solenoid valves for use in industrial machinery.
More information3 Port, 2-Ton Outdoor Heat Pump
Job Name: Tag# Submittal Data Sheet 3 Port, 2-Ton Outdoor Heat Pump 3MXS24NMVJU Efficiency SEER EER HSPF Non-Ducted 17.9 12.7 12.5 Ducted 14 9.7 8.2 Mixed 15.95 11.2 10.35 Performance Cooling (Btu/hr)
More informationSolkane 134a Thermodynamics
SOLVAY FLUOR SOLKANE - INFORMATION SERVICE Solkane 134a Thermodynamics SOLVAY FLUOR Technical Service - Refrigerants - PRODUCT BULLETIN NO.: T/09.04/01/E P.O. Box 220 Phone +49/511/857-2653 30002 Hannover
More informationThermal-Magnetic Circuit Breaker 2210-S2..
Thermal-Magnetic Circuit Breaker -S.. Description One, two and three pole thermal-magnetic circuit breakers with trip-free mechanism and toggle actuation (S-type TM CBE to EN 60934/IEC 934). Designed for
More informationKarl-Fischer Titration the method for determining water
Karl-Fischer Titration the method for determining water Quite some experienced analyst will be unpleasantly reminded by the pyridine smell, when hearing the name Karl Fischer. However, modern reagents
More informationThermal-Magnetic Circuit Breaker 2210-S2..
Thermal-Magnetic Circuit Breaker -S.. Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 6094/IEC 94). Designed for
More informationSilicon Temperature Sensors KT 100 KT 110 KT 130 KT 210 KT 230. KTY 11-x KTY 13-x KTY 21-x KTY 23-x KTY 19-6 KTY 16-6
Silicon Temperature Sensors KT 100 KT 110 KT 130 KT 210 KT 230 KTY 16-6 KTY 10-x KTY 11-x KTY 13-x KTY 21-x KTY 23-x KTY 19-6 Features Temperature dependent resistor with positive temperature coefficient
More informationThermal-Magnetic Circuit Breaker 2210-S2...
Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 6094/IEC 94). Designed for panel or plug-in mounting. Available
More informationThermal-Magnetic Circuit Breaker 2210-S2...
Thermal-Magnetic Circuit Breaker 0-S... Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 60934/IEC 934). Designed
More informationThermal-Magnetic Circuit Breaker 2210-S2..
Thermal-Magnetic Circuit Breaker -S.. Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 60934/IEC 934). Designed for
More informationTHE ENERGY 68,SAVING TDVI. exible Combine Modular 24, 26, 28, 30, 32, 34, 36, 38, 40, 42, 44 HP 60, 62, 64, 66 HP
I N V E RT E R ion Range exible Combine Modular TDV I TDV I TDV I INVERTER INVERTER INVERTER 14, 16, 18, 20, 22 HP TDV I 24, 26, 28, 30, 32, 34, 36, 38, 40, 42, 44 HP INVERTER INVERTER INVERTER TDV I INVERTER
More informationGlide Effect on Performance
Glide Effect on Performance ASHRAE, January 2016 Bachir Bella Regis Leportier* ASERCOM Azeotropic Mixtures The azeotropic (refrigerant) mixtures are usually binary mixtures that behave like a pure fluid
More informationFlow rates to 590 l/min
LM 400-40 - 4 Maximum pressure bar Flow rates to 590 l/min Technical data housing (Materials) ead: nodized luminium ousing: nodized luminium Manifolds: Steel - Painted black ypass valve: Steel -way ball
More informationCheck-Q-meter. Table of contents. Features. Functions. RE 27551/ /10 Replaces: Type FD
Check-Q-meter RE /0.0 /0 Replaces: 09.9 Type FD Nominal size... Series ax. Operating pressure 0 bar ax. Flow 0 l/min K9/ Table of contents Contents Page Features Functions Ordering details Symbols Functional
More informationElectro - Principles I
Electro - Principles I Capacitance The Capacitor What is it? Page 8-1 The capacitor is a device consisting essentially of two conducting surfaces separated by an insulating material. + Schematic Symbol
More informationEX-EMERGENCY LIGHT FITTINGS
EX-EMERGENCY LIGHT FITTINGS nllk 0...N 1-36 W Plastic version for Zone 2 and Zone 21/22 The explosion-protected light fittings of the series nllk 0 N are conform to the requirements of the ATEX-Directive
More informationVD1 CLC. Small Valves DIN-range with a higher k v -value
0 EN - Small Valves DIN-range with a higher k v -value VD CLC Valve body made of brass, mat nickel-plated DN, DN 0 and DN Internally and externally threaded (Rp / R) conforming to ISO 7- Manual knob /
More informationOil Retention and Pressure Drop of R134a, R1234yf and R410A with POE 100 in Suction Lines
Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2012 Oil Retention and Pressure Drop of R134a, R1234yf and R410A with POE 100
More informationAir Cooler Industry AC-LN 1-7 / ACA-LN 2-7 / ACAF-LN 2-7
ir ooler Industry -LN -7 / -LN -7 / F-LN -7 Symbol General The -LN -7 air cooler series can be used in all areas where either oil or water-glycol is to be cooled with air. The coolers with an axial fan
More informationKENYA BUREAU OF STANDARDS (KEBS)
CD13/SERV/ 2018 DRAFT KENYA STANDARD Dial thermometers - Specification Public Review Draft March 2018 KENYA BUREAU OF STANDARDS (KEBS) WORKING GROUP REPRESENTATION The following organizations were represented
More information2/2-way ball valve with electric rotary actuator, ball valve in plastic, DN 10-50
/way ball valve with electric rotary actuator, ball valve in plastic, N 50 Suitable for aggressive media High flow rate value Actuator with adjustable limit switches Visual position indicator Type 0 can
More informationPN LINE. PN Line. PX Line. PA Line. PU Line PX LINE. PV Line PA LINE & TUBINGS PU LINE PV LINE. Brass Push-in fittings
I NDEX PV LINE PX LINE PU LINE PA LINE & TUBINGS PN LINE Brass Push-in fittings Stainless Steel Push-in fittings Brass Standard fittings and Flexible Hoses Couplings and Multiple Connectors Function fittings
More informationSINGLE. Technical Data Book. Big Ceiling for Europe (R410A, 50Hz, H/P) Model : AC***JNCDEH (ODU: AC***JXAD*H)
SINGLE Technical Data Book Big for Europe (R4A, Hz, H/P) Model : AC***JNCDEH (ODU: AC***JXAD*H) History Version Modification Date Remark Ver.1. Release SINGLE Big for Europe.4.3 Ver.1.1 Modification for
More informationSurface-mounting Thermostats ATH Type Series
Page 1/9 urface-mounting Thermostats ATH eries k enclosure protection IP 54 k tested to IN EN 14597 (replacing IN 3440) Brief description Thermostats control and monitor thermal processes. Instruments
More informationSolkane 410 Thermodynamics
SOLVAY FLUOR SOLKANE - INFORMATION SERVICE Solkane 410 Thermodynamics SOLVAY FLUOR Technical Service - Refrigerants - Product Bulletin no.: T/09.04/04/E P.O. Box 0 Phone +49/511/857-653 3000 Hannover Fax
More informationFlow rates to 475 l/min
FMP Maximum pressure 0 bar Flow rates to 7 l/min Technical data PRSSUR FILTR Filter housing (Materials) ead: Cast iron (chemical heat treatment) ousing: Steel (chemical heat treatment) Bypass valve: Brass
More informationSafety valve with unit approval type MV..X.., SV..X..
Safety valve with unit approval type MV..X.., SV..X.. Operating pressure p max = 0 bar Flow Q max = 0 lpm Safety valve type CMVX 2.. with unit approval see D 77 TÜV These safety valves are intended for
More informationCRTE Power Capacitors
RTE Power apacitors General description RTE is the IAR last generation of metallized polypropylene film capacitors to be used for power factor correction and harmonic filtering in low voltage plants. Three
More informationEx-Floodlight PXLED. (Ex-Zone 1, 2, 21 and 22)
Ex-Floodlight PXLED (Ex-Zone 1, 2, 21 and 22) Lighting under harsh conditions The new modular LED floodlight series PXLED is suited for nearly every kind of lighting task in hazardous areas, including
More informationFlow rates to 485 l/min
FB Maximum pressure 0 bar Flow rates to 8 l/min Technical data Filter housing (Materials) ead: Cast iron (chemical heat treatment) ousing: Steel (chemical heat treatment) Bypass valve: Steel Check valve:
More informationFlow rates to 485 l/min
FB Maximum pressure 0 bar Flow rates to 8 l/min Technical data Filter housing (Materials) ead: Cast iron (chemical heat treatment) ousing: Steel (chemical heat treatment) Bypass valve: Steel Check valve:
More informationMetal oil filler and air breather filler caps. Bayonet connection. Reservoir holes. TA46 B (Materials)
Metal oil filler and air Series T 46 4 5 6 4 ayonet connection Ø 46 7 8 46 Reservoir holes T46 (Materials) M5 - Cover: Chrome Plated Steel - Filter element: Impregnated paper Polyurethane 64-6 - Flange:
More informationRefrigeration. 05/04/2011 T.Al-Shemmeri 1
Refrigeration is a process of controlled removal of heat from a substance to keep it at a temperature below the ambient condition, often below the freezing point of water (0 O C) 05/04/0 T.Al-Shemmeri
More informationAIR BREATHER FILTERS. Temperature from -25 C to +100 C
IR RETHER FILTERS The comprehensive series of breather filters makes it possible to meet all market demands. Metal and plastic styles suitable for use on mobile equipment are available. The function of
More informationAIR BREATHER FILTERS. Temperature from -25 to +100 C
IR BRETHER FILTERS The comprehensive series of breather filters makes it possible to meet all market demands. Metal and plastic styles suitable for use on mobile equipment are available. The function of
More informationø6, ø10, ø15, ø20, ø25, ø32, ø40, ø50, ø63 How to Order Switch rail Nil Standard stroke Refer to page 12 for standard stroke.
Magnetically Coupled Rodless Cylinder: Direct Mount ype Series ø, ø, ø, ø, ø, ø, ø, ø0, ø Direct mount type mm mm mm mm mm mm mm 0 0 mm mm 00 MB Piping type Both sides piping type Centralized piping type
More informationFlow rates to 750 l/min
FP Maximum pressure 0 bar Flow rates to 70 l/min Technical data Filter housing (Materials) ead: Cast iron (chemical heat treatment) ousing: Steel (chemical heat treatment) Bypass valve: AISI L (FP 0-0)
More informationFlow rates to 485 l/min
FB Maximum pressure 0 bar Flow rates to 8 l/min Technical data Filter housing (Materials) ead: Cast iron (chemical heat treatment) ousing: Steel (chemical heat treatment) Bypass valve: Steel Check valve:
More informationVariable Displacement Plug-In Motor A6VE. Series 6, for open and closed circuits Axial tapered piston, bent axis design
rueninghaus Hydromatik Series 6, for open and closed circuits xial tapered piston, bent axis design Size 28...20 Nom. pressure up to 400 bar Peak pressure up to 40 bar RE 9606/0.97 RE 9606/0.97 replaces
More informationsensonic II modular version
sensonic II sensonic II modular version Combination with impeller contact water meters With these dry running meters with magnetic coupling, the roller-type counter is fully evacuated and can also be rotated.
More informationcompact ejector, Series ECS with release valve with silencer with non-return valve, With filter vacuum switch: electronic 1x PNP and 1x analog
with release valve with silencer with non-return valve, With filter vacuum switch: electronic x PNP and x analog Ambient temperature min./max. +0 C / +0 C Medium temperature min./max. +0 C / + C Working
More informationSS Bimetal Dial Thermometers. Features. Ordering Codes. Fig
imetal ial hermometers he bimetal is a couple of metal plates, one put on top of another, which are different in coefficient of expansion with temperature. ig.1(a) shows the initial state and ig. 1(b)
More informationPRODUCT DATA SHEET. Eagle Eye Outdoor LED Module 3000K. RoHS Compliant. CUSTOMER :. DATE : REV : Rev. 1.0.
CUSTOMER :. DATE : 213. 3. 29. REV : Rev. 1.. PRODUCT DATA SHEET Eagle Eye Outdoor LED Module 3K MODEL NAME : LLDMWW-15K21A (Type II Lens - H:16 V:7 ) LLDMWW-15K22A (Type III Lens - H:135 V:6 ) LLDMWW-15K23A
More informationMPT Multifunction Multiport
MP Multifunction Multiport Maximum pressure 8 bar F l o w r a t e s t o 0 0 l / m i n echnical data housing (Materials) ead: luminium Cover: Nylon Bowl: Nylon Pressure Working pressure: 8 bar emperature
More informationFDE 211 Material & Energy Balances. Instructor: Dr. Ilgin Paker Yikici Fall 2015
FDE 211 Material & Energy Balances Instructor: Dr. Ilgin Paker Yikici Fall 2015 Agenda Process classification General mass balance equation Basic functions of Processes Process Flow Diagram Degree of Freedom
More informationOcean Acidification in a Cup Materials
Ocean Acidification in a Cup Ocean acidification is a problem that humans will have to deal with as we release more and more carbon dioxide into the atmosphere. This activity demonstrates how water can
More informationFlow rates to 750 l/min
FP Maximum pressure 0 bar Flow rates to 70 l/min Technical data Filter housing (Materials) ead: Cast iron (chemical heat treatment) ousing: Steel (chemical heat treatment) Bypass valve: AISI L (FP 00-0)
More informationNAME:.ADM NO: SCHOOL..CANDIDATE S SIGNATURE 232/1 PHYSICS PAPER 1 TIME 2 HOURS
NAME:.ADM NO: SCHOOL..CANDIDATE S SIGNATURE DATE: EMBU NORTH COMMON EVALUATION EXAMINATION 2 ND TERM YEAR 2018 232/1 PHYSICS PAPER 1 TIME 2 HOURS INSTRUCTIONS TO CANDIDATE: (a) Write your name and admission
More informationFunctional Genomics Research Stream. Lecture: February 17, 2009 Masses, Volumes, Solutions & Dilutions
Functional Genomics Research Stream Lecture: February 17, 2009 Masses, Volumes, Solutions & Dilutions Agenda Lab Work: Last Week New Equipment Solution Preparation: Fundamentals Solution Preparation: How
More informationData Sheet / Instructions. Dewpoint MeterO
Data Sheet / Instructions Dewpoint MeterO Dewpoint Meter ISO 8502-4: Preparation of steel substrates before application of paints and related products. Tests for the assessment of surface cleanliness.
More informationMultifunctional Thermostatic Circulation Valve MTCV
Multifunctional Thermostatic Circulation Valve MTCV Introduction Fig. 1 Basic version - A Fig. * Self-acting version with automatic disinfection function - B * thermometer is an accessory Fig. 3 Version
More informationSlimLine Sensors (SLS)
Force SlimLine Sensors (SLS) Measurement of Dynamic and Quasistatic Forces, 0 3 kn up to 0 80 kn Quartz sensor series with extremely flat design for measuring dynamic and quasistatic forces. High resolution,
More informationSodium, Na. Gallium, Ga CHEMISTRY Topic #2: The Chemical Alphabet Fall 2017 Dr. Susan Findlay See Exercises 11.1 to 11.4.
Sodium, Na Gallium, Ga CHEMISTRY 1000 Topic #2: The Chemical Alphabet Fall 2017 Dr. Susan Findlay See Exercises 11.1 to 11.4 Forms of Carbon The Chalcogens (Group 16) What is a chalcogen? Any element in
More informationSMD Top View LEDs EAPL4014WA1
SMD Top View LEDs Features Top View White LEDs Wide viewing angle Soldering methods: IR reflow soldering Pb-free ESD protection The product itself will remain within RoHS compliant version. Description
More informationFlow Divider Type MH2FA, Series 4X (Differential lock) Size 12 to 32 up to 420 bar up to 300 L/min
RE 8/0.98 8/0.9 Flow Divider Type MHF, eries X (Differential lock) ize to up to 0 bar up to 00 /min RE 8/0.98 Replaces: 0.9 Characteristics: Double-acting (dividing and summating) flow divider Fixed division
More informationBimetal Industrial Thermometers
Bimetal Industrial Thermometers 00 Order Number Description XX XX XX X XX XX Case Style Material Size Bushing Example: RG50-R translates to: R = Rear Mounting = 3" dial 50 = 1 2" NPT connection R = With
More informationDuctless Split Systems Floating Air
Ductless Split Systems Floating Air PURCHASER P.O. # DATE PROJECT LOCATION ENGINEER ARCHITECT SUBMITTED BY FOR APPROVAL FOR REFERENCE ITEM PLAN DESIGNATION QUANTITY COOLING BTU/H VOLTAGE FRIEDRICH MODEL
More informationFMP :41 Pagina 5 (1,1) FMP
FMP 6-07-006 9:4 Pagina 5 (,) FMP 6 FMP 6-07-006 9:4 Pagina 5 (,) SERIES FMP Working pressure 80 bar Style S Style Style T Style D Style V Style Z 7 FMP 6-07-006 9:4 Pagina 7 (,) Technical data Filter
More informationWhat is Science? Science is both a collection of knowledge and the process for building that knowledge.
Introduction to Science Junior Science What is Science? Science is both a collection of knowledge and the process for building that knowledge. Science asks questions about the natural world and looks for