Solenoid valve Types CSV 2 - CSV 22 (NC) and solenoid coil
|
|
- Sandra Nash
- 5 years ago
- Views:
Transcription
1 Data sheet Solenoid valve s CSV 2 - CSV 22 (NC) and solenoid coil CSV is a direct or servo-operated solenoid valve for liquid, suction, and hot gas lines with fluorinated refrigerants. CSV valves are for refrigeration, freezing, and air conditioning plants. Features y Designed for media temperatures up to 05 C / 22 F y Supplied as normally closed (NC) with de-energized coil y Compact construction with small dimensions, low weight for both valve and coil. y Simple and fast mounting of coil - clip-on / OFF DKRCC.PD.BB2.A3.02
2 Approvals y RoHS y Pressure Equipment Directive 97/23/EC (types CSV 2 ) Technical data Refrigerant R22, R34a, R404A, R507, R407C, and R290. For other refrigerants, contact Danfoss. Temperature of medium: C / F Maximum 30 C / 265 F during defrosting Note: CSV is not suitable for oil application. For detailed informations please contact Danfoss Special note for R290: the CSV 2/3/6 ignition risk is evaluated in accordance to ISO 549 and IEC See safety note on the bottom. Maximum working pressure 35 bar / 508 psig Rated capacity [KW] R22/R407C R34a R404A/R507 R290 Liquid CSV CSV CSV CSV CSV Suction vapour CSV CSV CSV CSV CSV Hot gas CSV CSV CSV CSV CSV Rated liquid and suction vapour capacity is based on: - evaporating temperature t e = -0 C - liquid temperature ahead of valve t l = 25 C - pressure drop in valve p = 0.5 bar Rated hot gas capacity is based on: - condensing temperature t c = 40 C - pressure drop across valve p = 0.8 bar - hot gas temperature t h = 65 C - subcooling of refrigerant t sub = 4 K The CSV2/3/6 can be applied on system with R290 as the working fluid. For countries where safety standards are not an indispensable part of the safety system, Danfoss recommends the installer gets a third party approval of any system containing flammable refrigerant. Note: Please follow specific selection criteria stated in the data sheet for this particular refrigerants. DKRCC.PD.BB2.A3.02 2
3 Ordering - ODF Connections (ODF) [in.] Min. Opening differential pressure with standard coil Δp Max. (=MOPD liquid ) K v m 3 / min Code no. CSV B B2000 Danfoss 32B0-CN-CSV B B B B B B B2044 Danfoss 32B04-CN-CSV CSV 0 CSV B B B B B B2008 CSV 20 CSV B B B B B B202 ) For detailed MOPD, for media in gas form, please contact Danfoss. Ordering - flare Danfoss 32B0.02-CN-CSV Connections (flare) [in.] Min. Opening differential pressure with standard coil Δp Max. (=MOPD liquid ) K v m 3 /min Code no. CSV B B B B B2034 ) For detailed MOPD, for media in gas form, please contact Danfoss. DKRCC.PD.BB2.A3.02 3
4 Ordering Solenoid coil with DIN Terminal box IP65 Special note for R290 The 034Z204 is validated in accordance to ISO 549, IEC (ref. IEC/EN ). Ignition risk is evaluated in accordance to ISO 549 and IEC ( ref. IEC/EN See safety note on the bottom. Please make sure that there is no spark, arc on the spade connection during the application. If coils are below IPx5, they must be protected against ultraviolet, moisture and major impact, especially the connection of coils. Always install a fuse ahead of the coil to avoid short circuit. The coil should be used in area of not more than pollution degree 2. Use of socket cable with suitable mechanical lock function to connect with coils. Follow the installation guide to mount the coil correctly. DIN plug Power consumption [W] Frequency [Hz] Voltage [V AC] Code no. CSV 2 CSV Z204 ) ) The 034Z204 is exclusively for China market. The coil selection for other regions, please contact Danfoss. Danfoss 042N Technical data Ambient temperature C / -4 3 F The 034Z204 can be applied on system with R290 as the working fluid. For countries where safety standards are not an indispensable part of the safety system, Danfoss recommends the installer to get a third party approval of the system containing flammable refrigerant. Note that the 034Z204 has NOT been verified ATEX or IECEx or IEC series zone 2 compliant. This product is only validated for system in compliance with ISO549, IEC (ref. IEC/EN ). It is responsability of the user to verify such compliance. Improper use can cause explosion, fire, leakage potentially causing death, personal injury, or damage to property. Note: Please follow specific selection criteria stated in the data sheet for this particular refrigerants. DKRCC.PD.BB2.A3.02 4
5 Liquid capacity Liquid capacity Q e [kw] at pressure drop across valve p R22/R407C CSV CSV CSV CSV CSV R34a CSV CSV CSV CSV CSV Capacities are based on: liquid temperature t l = 25 C ahead of valve evaporating temperature t e = -0 C, superheat 0 K When sizing valves, the plant capacity must be multiplied by a correction factor depending on liquid temperature t l ahead of valve / evaporator. When the corrected capacity is known, the selection can be made from the table. based on liquid temperature t l t l [ C] R22/R407C R34a DKRCC.PD.BB2.A3.02 5
6 Liquid capacity Liquid capacity Q e [kw] at pressure drop across valve p R404a/R507 CSV CSV CSV CSV CSV R290 CSV Capacities are based on: liquid temperature t l = 25 C ahead of valve evaporating temperature t e = -0 C, superheat 0 K When sizing valves, the plant capacity must be multiplied by a correction factor depending on liquid temperature t l ahead of valve / evaporator. When the corrected capacity is known, the selection can be made from the table. based on liquid temperature t l t l [ C] R404a/R R DKRCC.PD.BB2.A3.02 6
7 Capacity Suction p Suction vapour capacity Q e [kw] at evaporating temperature t e [ C] R22/R407C CSV CSV CSV CSV CSV Capacities are based on: - liquid temperature t l = 25 C ahead of evaporator. The table values refer to the evaporator capacity and are given as a function of evaporating temperature t e and pressure drop p across valve. Capacities are based on dry, saturated vapour ahead of valve. During operation with superheated vapour ahead of valve, the capacities are reduced by 4% for each 0 K superheat. When sizing valves. the evaporator capacity must be multiplied by a correction factor depending on liquid temperature t l ahead of expansion valve. When the corrected capacity is known, the selection can be made from the table. for evaporating temperature t e t l [ C] R22/R407C DKRCC.PD.BB2.A3.02 7
8 Capacity Suction p Suction vapour capacity Q e [kw] at evaporating temperature t e [ C] R34a CSV CSV CSV CSV CSV Capacities are based on - liquid temperature t l = 25 C ahead of evaporator. The table values refer to the evaporator capacity and are given as a function of evaporating temperature t e and pressure drop p across valve. Capacities are based on dry, saturated vapour ahead of valve. During operation with superheated vapour ahead of valve, the capacities are reduced by 4% for each 0 K superheat. When sizing valves. the evaporator capacity must be multiplied by a correction factor depending on liquid temperature t l ahead of expansion valve. When the corrected capacity is known, the selection can be made from the table. for evaporating temperature t e t l [ C] R34a DKRCC.PD.BB2.A3.02 8
9 Capacity Suction CSV 2 CSV 0 CSV 5 CSV 20 CSV 22 p Capacities are based on - liquid temperature t l = 25 C ahead of evaporator. Suction vapour capacity Q e [kw] at evaporating temperature t e [ C] R404a/R The table values refer to the evaporator capacity and are given as a function of evaporating temperature t e and pressure drop p across valve. Capacities are based on dry, saturated vapour ahead of valve. During operation with superheated vapour ahead of valve, the capacities are reduced by 4% for each 0 K superheat. When sizing valves. the evaporator capacity must be multiplied by a correction factor depending on liquid temperature t l ahead of expansion valve. When the corrected capacity is known, the selection can be made from the table. for evaporating temperature t e t l [ C] R404a/R DKRCC.PD.BB2.A3.02 9
10 Capacity Suction p Suction vapour capacity Q e [kw] at evaporating temperature t e [ C] R CSV Capacities are based on: - liquid temperature t l = 25 C ahead of evaporator. The table values refer to the evaporator capacity and are given as a function of evaporating temperature t e and pressure drop p across valve. Capacities are based on dry, saturated vapour ahead of valve. During operation with superheated vapour ahead of valve, the capacities are reduced by 4% for each 0 K superheat. When sizing valves. the evaporator capacity must be multiplied by a correction factor depending on liquid temperature t l ahead of expansion valve. When the corrected capacity is known, the selection can be made from the table. for evaporating temperature t e t l [ C] R DKRCC.PD.BB2.A3.02 0
11 Capacity Suction Hot gas defrosting With hot gas defrosting it is not normally possible to select a valve from condensing temperature t c and evaporating temperature t e. This is because the pressure in the evaporator as a rule quickly rises to a value near that of the condensing pressure. It remains at this value until the defrosting is finished. In most cases therefore, the valve will be selected from condensing temperature t c and pressure drop p across the valve. as shown in the example for heat recovery. Heat recovery The following is given: y Refrigerant = R22/R407C y Evaporating temperature t e = -30 C y Condensing temperature t c = 40 C y Hot gas temperature ahead of valve t h = 85 C y Heat recovery condenser yield Q h = 8 kw The capacity table for R22/R407C with t c = 40 C gives the capacity for an CSV 5 as.96 kw, when pressure drop p is 0.2 bar. The required capacity is calculated as : Qtable x fevaporator x fhot_temperature = Qh The correction factor for t e = -30 C is given in the table as The correction for hot gas temperature t h = 85 C has been calculated as 4% which corresponds to a factor of.04. Qh must be corrected with factors found: With p = 0.2 bar is Qh =.96 x 0.95 x.04 =.82 kw. With p = 0. bar. Qh becomes 8.49 x 0.95 x.04 = 8.4 kw. A CSV 0 would also be able to give the required capacity, but with p at approx. 0.3 bar. The CSV 0 is therefore too small. The CSV 5 is big enough to provide sufficient capactiy at p of approx. 0. bar could be obtained. Result: An CSV 5 is the correct valve for the given conditions. DKRCC.PD.BB2.A3.02
12 Capacity Hot gas across valve p Hot gas capacity Qh [kw] Evaporating temp. t e = -0 C. Hot gas temp. t h = t c 25 C. Subcooling t sub = 4 K Condensing temperature t c [ C] R34a CSV CSV An increase in hot gas temperature t h of 0 K, based on t h = t c 25 C, reduces valve capacity approx. 2% and vice versa. A change in evaporating temperature t e changes valve capacity; see correction factor table below. When sizing valves, the table value must be multiplied by a correction factor depending on evaporating temperature t e. for evaporating temperature t e t e [ C] R34a DKRCC.PD.BB2.A3.02 2
13 Capacity Hot gas across valve p Hot gas capacity Qh [kw] Evaporating temp. t e = -0 C. Hot gas temp. t h = t c 25 C. Subcooling t sub =4 K Condensing temperature t c [ C] R34a CSV CSV CSV An increase in hot gas temperature t h of 0 K, based on t h = t c 25 C, reduces valve capacity approx. 2% and vice versa. A change in evaporating temperature t e changes valve capacity; see correction factor table below. When sizing valves, the table value must be multiplied by a correction factor depending on evaporating temperature t e. for evaporating temperature t e t e [ C] R34a DKRCC.PD.BB2.A3.02 3
14 Capacity Hot gas across valve p Hot gas capacity Qh [kw] Evaporating temp. t e = -0 C. Hot gas temp. t h = t c 25 C. Subcooling t sub =4 K Condensing temperature t c [ C] R404a/R CSV CSV An increase in hot gas temperature t h of 0 K, based on t h = t c 25 C, reduces valve capacity approx. 2% and vice versa. A change in evaporating temperature t e changes valve capacity; see correction factor table below. When sizing valves, the table value must be multiplied by a correction factor depending on evaporating temperature t e. for evaporating temperature t e t e [ C] R404A/R DKRCC.PD.BB2.A3.02 4
15 Capacity Hot gas across valve p Hot gas capacity Qh [kw] Evaporating temp. t e = -0 C. Hot gas temp. t h = t c 25 C. Subcooling t sub =4 K Condensing temperature t c [ C] R404a/R CSV CSV CSV An increase in hot gas temperature t h of 0 K, based on t h = t c 25 C, reduces valve capacity approx. 2% and vice versa. A change in evaporating temperature t e changes valve capacity; see correction factor table below. When sizing valves, the table value must be multiplied by a correction factor depending on evaporating temperature t e. for evaporating temperature t e t e [ C] R404A/R DKRCC.PD.BB2.A3.02 5
16 Capacity Hot gas across valve p Hot gas capacity Qh [kw] Evaporating temp. t e = -0 C. Hot gas temp. t h = t c 25 C. Subcooling t sub = 4 K Condensing temperature t c [ C] R22/R407C CSV CSV An increase in hot gas temperature t h of 0 K, based on t h = t c 25 C, reduces valve capacity approx. 2% and vice versa. A change in evaporating temperature t e changes valve capacity; see correction factor table below. When sizing valves, the table value must be multiplied by a correction factor depending on evaporating temperature t e. for evaporating temperature t e t e [ C] R22/R407C DKRCC.PD.BB2.A3.02 6
17 Capacity Hot gas across valve p Hot gas capacity Qh [kw] Evaporating temp. t e = -0 C. Hot gas temp. t h = t c 25 C. Subcooling t sub = 4 K Condensing temperature t c [ C] R22/R407C CSV CSV CSV An increase in hot gas temperature t h of 0 K, based on t h = t c 25 C, reduces valve capacity approx. 2% and vice versa. A change in evaporating temperature t e changes valve capacity; see correction factor table below. When sizing valves, the table value must be multiplied by a correction factor depending on evaporating temperature t e. for evaporating temperature t e t e [ C] R22/R407C DKRCC.PD.BB2.A3.02 7
18 Capacity Hot gas across valve p Hot gas capacity Qh [kw] Evaporating temp. t e = -0 C. Hot gas temp. t h = t c 25 C. Subcooling t sub = 4 K Condensing temperature t c [ C] R CSV An increase in hot gas temperature t h of 0 K, based on t h = t c 25 C, reduces valve capacity approx. 2% and vice versa. A change in evaporating temperature t e changes valve capacity; see correction factor table below. When sizing valves, the table value must be multiplied by a correction factor depending on evaporating temperature t e. for evaporating temperature t e t e [ C] R DKRCC.PD.BB2.A3.02 8
19 Dimensions and weights [kg] 45 L L2 H B L CSV 2 CSV 0 CSV 22 Connection (ODF) [in] B H L L L2 Weight [Kg] CSV CSV 0 CSV CSV CSV Coil 0. DKRCC.PD.BB2.A3.02 9
20 Dimensions and weights [kg] Danfoss 32B0005 H2 H H3 L Ø5.2 C ØB Connection (flare) [in] B H L C H H2 H3 Weight [Kg] CSV DKRCC.PD.BB2.A
Solenoid valves Type EVUL
Data sheet Solenoid valves EVUL EVUL solenoid valves are designed to fit into compact refrigeration systems. Available in servo operated versions they can be applied in liquid, suction, and hot gas lines.
More informationSolenoid valves Type EVR 2 g 40 NC/ NO New EVR 6 with Steel cover design
MAKING MODERN LIVING POSSIBLE Technical brochure Solenoid valves EVR 2 g 40 NC/ NO New with Steel cover design EVR is a direct or servo operated solenoid valve for liquid, suction, and hot gas lines with
More informationSolenoid valve Types EVR 2 - EVR 40
Data sheet Solenoid valve s EVR 2 - EVR 40 EVR is a direct or servo operated solenoid valve for liquid, suction, and hot gas lines with HCFC and HFC refrigerants. EVR valves are supplied complete or as
More informationDirect-operated 2/2-way compact solenoid valves Type EV210A
Data sheet Direct-operated 2/2-way compact solenoid valves Type EV210A EV210A covers a wide range of small, directoperated 2/2-way solenoid valves for use in industrial machinery. The compact design together
More informationSolenoid valves 2/2-way direct-operated type EV210A
MAKING MODERN LIVING POSSIBLE Data sheet Solenoid valves 2/2-way direct-operated type EV210A EV210A covers a wide range of small, direct-operated 2/2-way solenoid valves for use in industrial machinery.
More information4 Way Reversing Valve
STANDARD 4 Way Reversing Valve SHF series four-way reversing valves are applicable for heat pump systems such as central, unitary and room air conditioners to realize switching between cooling mode and
More informationDirect-operated 2/2-way solenoid valves Type EV210B
Data sheet Direct-operated 2/2-way solenoid valves Type EV20B EV20B covers a wide range of direct-operated 2/2-way solenoid valves for universal use. EV20B is a very robust valve program with high performance
More information/2 way valves (solenoid actuated diaphragm with forced lifting) 1/4... 2
/ way valves (solenoid actuated diaphragm with forced lifting) /4... Damped operation Operation without differential Suitable for vacuum igh flow rate For systems with low or fluctuating Brass body Wide
More informationThermostatic expansion valves TUA/TUAE
MAKING MODERN LIVING POSSIBLE Technical brochure Thermostatic expansion valves A/AE www.danfoss.com Thermostatic expansion valves, type A/AE Contents Page Introduction... Features... Standard range...
More informationAIR CONDITIONER (SPLIT TYPE) SERVICE MANUAL
AIR CONDITIONER (SPLIT TYPE) SERVICE MANUAL FILE No. A10-023-1 REVISION 1 : Mar.2012 Re-edit version.( file volume down) Contents have NOT been changed. Model name: RAS-M10PKVP-E RAS-M13PKVP-E RAS-M16PKVP-E
More informationAIR CONDITIONING COMMERCIAL REFRIGERATION HEAT PUMP STANDARD PRODUCT CATALOGUE
AIR CONDITIONING COMMERCIAL REFRIGERATION HEAT PUMP STANDARD PRODUCT CATALOGUE CA-STD- SUMMARY SANHUA Strive for perfection, Pursuit of excellence 4 WAY REVERSING VALVE SHF SERIES 4 WAY REVERSING VALVE
More informationHigh pressure sight glass (PS = 52 bar) Types SGP N, SGP I and SGP X
MAKING MOERN IVING POSSIBE ata sheet igh pressure sight glass (PS = 2 bar) Types SGP N, SGP I and SGP X Sight glasses are used to indicate:. The condition of the refrigerant in the liquid line of the plant.
More informationInstallation guide 862 MIT / MIR
Installation guide 862 MIT / MIR in combination with: 864 MTT or 863 MRT or (dual) spot element November 2005 Part no. 4416.232_Rev3 Enraf BV PO Box 812 2600 AV Delft Netherlands Tel. : +31 15 2701 100
More informationPressure transmitters for industrial applications MBS 32 and MBS 33
Data sheet Pressure transmitters for industrial applications MBS 32 and MBS 33 The standard pressure transmitters MBS 32 and MBS 33 are designed for use in almost all industrial applications, and offer
More informationThermal-Magnetic Circuit Breaker 2210-S2...
Thermal-Magnetic Circuit Breaker 0-S... Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 60934/IEC 934). Designed
More informationThermal-Magnetic Circuit Breaker 2210-S2...
Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 6094/IEC 94). Designed for panel or plug-in mounting. Available
More informationMAKING MODERN LIVING POSSIBLE. Thermostatic expansion valve Type TUB/TUBE and TUC/TUCE REFRIGERATION AND AIR CONDITIONING.
MAKING MODERN LIVING POSSIBLE Thermostatic expansion valve Type B/BE and C/CE REFRIGERATION AND AIR CONDITIONING Technical leaflet Thermostatic expansion valve, type B/BE and C/CE Contents Page Introduction........................................................................................
More informationThermostatic expansion valves TUB/TUBE and TUC/TUCE
MAKING MODERN LIVING POSSIBLE Technical brochure Thermostatic expansion valves B/BE and C/CE www.danfoss.com Thermostatic expansion valve, type B/BE and C/CE Contents Page Introduction........................................................................................
More informationThermal-Magnetic Circuit Breaker 2210-T2...
Thermal-Magnetic Circuit Breaker 0-T... Description One, two and three pole thermal-magnetic circuit breakers with trip-free mechanism and toggle actuation (S-type TM CBE to EN 6094/IEC 94). Featuring
More informationAIR CONDITIONING STANDARD COMMERCIAL REFRIGERATION HEAT PUMP PRODUCT CATALOGUE
AIR CONDITIONING COMMERCIAL REFRIGERATION HEAT PUMP STANDARD PRODUCT CATALOGUE CA-STD-EN-R1013 SUMMARY SANHUA Strive for perfection, Pursuit of excellence 04 4 WAY REVERSING VALVE SHF SERIES 08 4 WAY
More informationRefrigeration. 05/04/2011 T.Al-Shemmeri 1
Refrigeration is a process of controlled removal of heat from a substance to keep it at a temperature below the ambient condition, often below the freezing point of water (0 O C) 05/04/0 T.Al-Shemmeri
More informationThermal-Magnetic Circuit Breaker 2210-S2..
Thermal-Magnetic Circuit Breaker -S.. Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 6094/IEC 94). Designed for
More informationThermal-Magnetic Circuit Breaker 2210-S2..
Thermal-Magnetic Circuit Breaker -S.. Description One, two and three pole thermal-magnetic circuit breakers with trip-free mechanism and toggle actuation (S-type TM CBE to EN 60934/IEC 934). Designed for
More information5SJ4...-.HG Circuit Breakers to IEC and UL 489
Siemens AG 009 5SJ...-.HG Circuit Breakers to IEC and UL 89 BETA Low-Voltage Circuit Protection Compliance with industry standards is a must in today's manufacturing environment. Worldwide acceptance is
More informationThermal-Magnetic Circuit Breaker 2210-S2..
Thermal-Magnetic Circuit Breaker -S.. Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 60934/IEC 934). Designed for
More informationVD1 CLC. Small Valves DIN-range with a higher k v -value
0 EN - Small Valves DIN-range with a higher k v -value VD CLC Valve body made of brass, mat nickel-plated DN, DN 0 and DN Internally and externally threaded (Rp / R) conforming to ISO 7- Manual knob /
More information2.12. Ex-Linear light fittings for fluorescent lamps - max. ambient temperature + 60 C - nllk W - 58 W for Zone 2 and 22
.1 Ex-Linear light fittings for fluorescent lamps - max. ambient temperature + C - nllk 09 18 W - 58 W for Zone and The lighting solution for high temperatures up to C The linear luminaires series nllk
More information4/4-way servo solenoid directional control valves, directly operated, with electrical position feedback and on-board electronics (OBE)
4/4-way servo solenoid directional control valves, directly operated, with electrical position feedback and on-board electronics (OBE) RE 9035/. Replaces: 05. 1/1 Type 4WRPEH 6 Size 6 Unit series X Maximum
More informationFilm Capacitors. EMI suppression capacitors. Date: June 2018
Film Capacitors EMI suppression capacitors Date: June 2018 EPCOS AG 2018. Reproduction, publication and dissemination of this publication, enclosures hereto and the information contained therein without
More informationPressure Measurement. Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level 2/27
Overview Siemens AG 011 Function s are for measuring the liquid levels in wells, tanks, channels and dams. Diaphragm p Sensor U const. U + (brown) I EM I -1 (blue) 0, U B s are submersible sensors for
More informationLamp and Control Panel (Lamp Panel)
www.reinhausen.com Lamp and Control Panel (Lamp Panel) Operating Instructions BA 47/0 EN NOTE! Changes may have been made to a product after going to press with this documentation. We expressly reserve
More informationPHOENIX CONTACT - 04/2016. Features
Signal conditioner Data sheet 100238_de_06 1 Description PHOENIX CONTACT - 04/2016 Features The MCR-C-UI-UI(-450)-DCI(-NC) 3-way isolation amplifier is used to electrically isolate and convert analog signals.
More informationEliminator Liquid line filter driers, Type DCL and DML
MAKING MODERN LIVING POSSIBLE Eliminator Liquid line filter driers, Type DCL and DML Flare connection Solder connection (copper) REFRIGERATION & AIR CONDITIONING DIVISION Technical leaflet Contents Page
More informationDATA SHEET POSITIVE TEMPERATURE COEFFICIENT AC/DC POWER SUPPLY SMD0603 series
Product specification November 05, 201 V.0 DATA SHEET AC/DC POWER SUPPLY series RoHS compliant & Halogen free 2 Positive Temperature Coefficient (PTC) Data Sheet Description The 0603 series provides miniature
More informationDMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm
DMP P Industrial Pressure Transmitter Process Connections With Flush Welded Stainless Steel accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 % FSO Nominal pressure from 0... 00 mbar up
More informationcompact ejector, Series ECS with release valve with silencer with non-return valve, With filter vacuum switch: electronic 1x PNP and 1x analog
with release valve with silencer with non-return valve, With filter vacuum switch: electronic x PNP and x analog Ambient temperature min./max. +0 C / +0 C Medium temperature min./max. +0 C / + C Working
More information4.2. Ex-Ceiling light fittings AB 80 / AB 05 LED / AB 05 / AB 12 NAV 70. (Zone 1, 2, 21, 22)
.2 Ex-Ceiling light fittings AB 8 / AB 5 LED / AB 5 / AB 12 NAV 7 (Zone 1, 2, 21, 22) The wall and ceiling light fixtures for particularly difficult operating conditions The impact-resistant and flameproof
More informationMCB NB1-63H Miniature Circuit Breaker
NB-H Miniature Circuit Breaker. General. Function protection of circuits against short-circuit currents, protection of circuits against overload currents, switch, isolation, NB-H circuit-breakers are used
More informationOperating instructions Pressure sensor PN / / 2007
Operating instructions Pressure sensor PN42 704298 / 00 0 / 2007 Contents afety instructions... 3 2 Function and features... 4 3 Function... 5 3. witching function... 5 4 Installation... 5 5 Electrical
More informationNon-Contact Safety Systems CMS
Selection table for non-contact safety system // Evaluation units Connection Desi Read head contact assembly Assured switch-on distance S ao [mm] Assured switch-on distance S ar [mm] Number of outputs
More informationEX-EMERGENCY LIGHT FITTINGS
EX-EMERGENCY LIGHT FITTINGS nllk 0...N 1-36 W Plastic version for Zone 2 and Zone 21/22 The explosion-protected light fittings of the series nllk 0 N are conform to the requirements of the ATEX-Directive
More informationEX-CONTROL AND DISTRIBUTION SYSTEMS
EX-CONTROL AND DISTRIBUTION SYSTEMS Cooper Crouse-Hinds 00 - all rights reserved EX-DISTRIBUTION IN PLASTIC DESIGN. EX-DISTRIBUTION IN STAINLESS STEEL EX-D BUILT-IN COMPONENTS.. 9 EX-E EMPTY ENCLOSURES
More informationMETALLIZED POLYPROPYLENE AC FILTERING CAPACITORS
METALLIZED POLYPROPYLENE AC FILTERING CAPACITORS Technology looking ahead With the new LNF series a new level of safety for the AC capacitors has been reached: Active safety: When the capacitor is stressed
More informationSafety Precautions WARNING If critical situations that could lead to user s death or serious injury is assumed by mishandling of the product.
Safety Precautions Observe the following notices to ensure personal safety or to prevent accidents. To ensure that you use this product correctly, read this User s Manual thoroughly before use. Make sure
More informationTHE ENERGY 68,SAVING TDVI. exible Combine Modular 24, 26, 28, 30, 32, 34, 36, 38, 40, 42, 44 HP 60, 62, 64, 66 HP
I N V E RT E R ion Range exible Combine Modular TDV I TDV I TDV I INVERTER INVERTER INVERTER 14, 16, 18, 20, 22 HP TDV I 24, 26, 28, 30, 32, 34, 36, 38, 40, 42, 44 HP INVERTER INVERTER INVERTER TDV I INVERTER
More informationDMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm
DMP Pi Precision Pressure Transmitter pressure ports and process connections with flush welded stainless steel diaphragm accuracy according to IEC 600: 0, % FSO Nominal pressure from 0... 00 mbar up to
More informationv = m / s Thermal Flow Sensors TA with thin-film sensor element Probes Probe Guides Measuring Tubes
Thermal Flow Sensors TA with thin-film sensor element Probes Probe Guides Measuring Tubes Examples of Application Flow measurements also in hazardous locations X zone 0 or zone 1 in clean rooms in air
More information8 Installation Equipment
8 Installation Equipment Plugs and Sockets CES System Series 8, 88, 8, 881 Te plugs and sockets in te CES system comply wit CEE publication 1 and European standards EN 0 01. Te small 1 A socket as switcing
More informationDMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor
DMP Industrial Pressure Transmitter for Low Pressure Stainless Steel Sensor accuracy according to IEC 60770: : 0.5 % FSO option: 0.5 / 0. % FSO Nominal pressure from 0... 00 mbar up to 0... 60 bar Output
More informationTransmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level
Overview Function s are for measuring the liquid levels in wells, tanks, channels and dams. Sensor Diaphragm p U const. U +2 (brown) I EM I - (blue) 0, U B s are submersible sensors for hydrostatic level
More informationM2 SERIES THERMOSTATS 0 F to 240 F, Narrow Differential, Hermetically Sealed ½
M2 SERIES THERMOSTATS 0 F to 240 F, Narrow Differential, Hermetically Sealed ½ Introduction The Klixon M2 thermostat is constructed with a snap acting bimetal disc that serves as the actuating element.
More informationCheck-Q-meter. Table of contents. Features. Functions. RE 27551/ /10 Replaces: Type FD
Check-Q-meter RE /0.0 /0 Replaces: 09.9 Type FD Nominal size... Series ax. Operating pressure 0 bar ax. Flow 0 l/min K9/ Table of contents Contents Page Features Functions Ordering details Symbols Functional
More informationOperating instructions Magnetic-inductive flow meter SM6x04 SM7x04 SM8x04
Operating instructions Magnetic-inductive flow meter SM6x04 SM7x04 SM8x04 UK 80223776 / 00 11 / 2018 Contents 1 Preliminary note...3 2 Safety instructions...4 3 Functions and features...4 4 Function...5
More informationDMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm
DMP Pi Precision Pressure Transmitter pressure ports and process connections with flush welded stainless steel diaphragm accuracy according to IEC 600: 0, % FSO Nominal pressure from 0... 00 mbar up to
More informationVarius SUMMARY OF MODELS OF HRC FUSE-LINKS
SUMMARY OF MODELS OF HRC FUSE-LINKS Type PNA000 PHNA000 PNA00 PHNA00 Rated current I n up to A up to 0 A up to A up to 0 A Rated voltage U n AC 00 V, 00 V 90 V 00 V 90 V DC 0 V 0 V 0 V 0 V Fuse-link size
More informationFLT5A FLT5A. abc. abc. Thermometer User Guide. Thermometer User Guide. Internet:
abc instruments international FLT5A Thermometer Land Instruments International Dronfield, S18 1DJ England Telephone: (1246) 417691 Facsimile: (1246) 41585 Email: infrared.sales@landinst.com Internet: www.landinst.com
More information4.13. Ex-Floodlights of the series FMV LED / NSSFMV. (Zone 2, 22) service life and a high level of efficiency. NFMV floodlights for highpressure
.13 Ex-Floodlights of the series / (Zone 2, 22) The powerful LED floodlights FMV LED The new series of energy-saving FMV floodlights in LED technology are ideal for all general lighting applications in
More informationFL ballasts Electronic fixed output. PC TC PRO sr 1/2x11 42 W PC PRO compact
FL ballasts EL HE PC TC PRO sr 1/2x11 42 W PC PRO compact Product description CELMA Energy Efficiency Index A2 BAT / A2 T Nominal life-time up to 50,000 h (at ta 50 C with a failure rate max. 0.2 % per
More informationAIR COOLED CONDENSING UNIT
NEW EVOLUTION SERIES AIR COOLED CONDENSING UNIT OUTDOOR AIR COOLED CONDENSING UNIT ORIGINAL MANUFACTURED EQUIPMENT NEW EVOLUTION 7 & 8 SERIES BA-506-5 AUS Evolution Air Cooled Condensing Unit Series Content
More informationBETA Protecting Miniature Circuit Breakers
Siemens AG 00 / Product overview / High-capacity range 000 A 0000 A 0000 A, high current 0000 A, universal current 000 A ka /0 Comfort range with plug-in terminal / Compact range +N in MW / Additional
More informationASPT Series. Multi-Position, Internal TXV. Air Handler 1½ to 5 Tons
Series Multi-Position, Internal TXV Product Features Internal factory-installed thermal expansion valves for cooling and heat pump applications Direct drive, multi-speed ECM blower motor All-aluminum evaporator
More informationAccumulators Virginia KMP Suction Line Accumulators
Accumulators Virginia KMP Suction Line Accumulators The Virginia KMP suction line accumulator's purpose is to prevent excessive quantities of liquid refrigerant and oil from returning to the compressor.
More informationLow Drop Voltage Regulator TLE 4296
Low Drop Voltage Regulator TLE 4296 Features Three versions: 3.0 V, 3.3 V, 5.0 V Output voltage tolerance ±4% Very low drop voltage Output current: 30 ma Inhibit input Low quiescent current consumption
More informationPressure Measurement Single-range transmitters for general applications
Siemens AG 07 Overview Function SITRANS LH00 Transmitter for hydrostatic level U const. p U I EM Sensor Connection for auxiliary power supply Vent pipe with humidity filter Protective conductor connection/
More informationLow Drop Voltage Regulator TLE
Low Drop Voltage Regulator TLE 4296-2 Features Two versions: 3.3 V, 5.0 V Output voltage tolerance ±4% Very low drop voltage Output current: 30 ma Inhibit input Low quiescent current consumption Wide operation
More informationBrushless DC Variable Speed Compressor Technical Data Sheet
R134a V DC VARIABLE SPEED Brushless DC Variable Speed Compressor Technical Data Sheet General Information Compressor Part Number (Stationary) CASCADE0005 (140 per pallet) Compressor Part Number (Mobile)
More informationTable of Contents Pin-Configuration Selection Guide for HDE, HDS, & EFP
Table of Contents -Configuration Selection Guide for HDE, HDS, & EFP Service Voltage Rating... Electrical Service Ratings... Ampacity Ratings by Contact... Electrical Service Ratings Explained... Operating
More information2-way proportional throttle valve for block installation
-way proportional throttle valve for block installation Types FES; FESE Sizes to Component series X Maximum operating pressure bar Maximum flow 800 l/min at Δp = 0 bar Table of contents Contents Page Features
More informationKM-70 Panel-mounting Thermostat
KM-70 Panel-mounting Thermostat B 60.2045.0 Operating Instructions 2008-10-24/00073778 Please read these Operating Instructions before commissioning the instrument. Keep the manual in a place that is accessible
More informationVRF Technical Data Book
VRF Technical Data Book DVM S for Euro_ET (R4A, Hz, HP) Model : Premium (Compact / Energy Efficiency) Type Standard Type History Version Modification Date Remark Ver. 1. Release DVM S (R4A, Hz, HP) for
More informationPTF30 Series. Features. Ordering information. G 6 N N F8 (0 to 5 kgf/cm 2 ) PTF30
eries Features Best pressure transmission solution for small and middle sized project such as indoor heating and air conditioning, water and sewer, or incinerator, etc. Improves noise resistance and minimize
More informationInstallation Operation Commissioning Maintenance
NA 09.13 H 09-2011 Microchip and LCD display electronic regulation and signaling electronic module for liquid coolers and heat pumps Installation Operation Commissioning Maintenance 1 CONTENTS 1 IMPORTANT
More informationSurface-mounting Thermostats ATH Type Series
Page 1/9 urface-mounting Thermostats ATH eries k enclosure protection IP 54 k tested to IN EN 14597 (replacing IN 3440) Brief description Thermostats control and monitor thermal processes. Instruments
More information4/3-way servo solenoid directional control valves with electrical position feedback (Lvdt DC/DC) (ruggedized design)
4/3-way servo solenoid directional control valves with electrical position feedback (Lvdt DC/DC) (ruggedized design) Type 4WRL10...25 Sizes (N) 10, 16, 25 Unit series 3 Maximum working pressure P,, 350
More informationBrushless DC Variable Speed Compressor Technical Data Sheet
R134a V DC VARIABLE SPEED Brushless DC Variable Speed Compressor Technical Data Sheet General Information Compressor Part Number (Stationary) CASCADE0006 (140 per pallet) Compressor Part Number (Mobile)
More informationSales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,
E X - L I G H T F I T T I N G S nllk 0... 1 - W All-plastic design for Zone 2 and Zone 21/22 The explosion-protected light fittings of the series nllk 0 conform to the requirements of the ATEX-Directive
More informationCooling Water Flow Regulator
Temperature controlled, indirectly and directly actuated diaphragm valves / seat valves Port size G 3/8 to G DN 0 to DN 0 ontinuous regulation High accuracy No auxiliary energy required Technical data
More informationLevel Sensor PanCake PR 6251 and Mounting Kit PR 6051
Level Sensor PanCake PR 6251 and Mounting Kit PR 6051 The space-saving solution for simple applications The sensors of the PR 6251 series have been specially designed for simple weighing of silos and horizontal
More informationMultifunctional Thermostatic Circulation Valve MTCV
Multifunctional Thermostatic Circulation Valve MTCV Introduction Fig. 1 Basic version - A Fig. * Self-acting version with automatic disinfection function - B * thermometer is an accessory Fig. 3 Version
More informationBETA Protecting. Low-Voltage Fuse Systems. LV HRC fuse links. 3/36 Siemens ET B1 2008
LV HRC fuse links Overview LV HRC fuses are used for installation systems in non-residential, commercial and industrial buildings as well as in switchboards of power supply companies. They therefore protect
More informationv = 00,20 m/s Thermal Flow Sensors TA with thin-film sensor element Probes Probe guides Measuring tubes
with thin-film sensor element Probes Probe guides Measuring tubes Examples of Application Flow measurements also in hazardous locations Ex zone 0 or zone 1 in clean rooms in air conditioning and ventilating
More informationSafety valve with unit approval type MV..X.., SV..X..
Safety valve with unit approval type MV..X.., SV..X.. Operating pressure p max = 0 bar Flow Q max = 0 lpm Safety valve type CMVX 2.. with unit approval see D 77 TÜV These safety valves are intended for
More informationMethod of Measuring Machinery Sound Within an Equipment Space
ANSI/AHRI Standard 575 (Formerly ARI Standard 575) 2008 Standard for Method of Measuring Machinery Sound Within an Equipment Space Price $15.00 (M) $30.00 (NM) Printed in U.S.A. 8Copyright 1994, by Air-Conditioning
More informationLow Drop Voltage Regulator TLE 4295
Low Drop Voltage Regulator TLE 4295 Features Four versions: 2.6 V, 3.0 V, 3.3 V, 5.0 V tolerance ±4% Very low drop voltage Output current: 30 ma Power fail output Low quiescent current consumption Wide
More informationEx-Floodlights of the series FMV LED / NFMV / NSSFMV. Stainless steel NSSFMV floodlights for particularly. in harsh environments
.13 Ex-Floodlights of the series / / (Zone 2, 21, 22) The powerful LED floodlights FMV/nFMV LED The new series of energy-saving FMV floodlights in LED technology are ideal for all ge neral lighting applications
More informationTurbine Meter TRZ 03 PRODUCT INFORMATION. Reliable Measurement of Gas
Turbine Meter TRZ 0 PRODUCT INFORMATION Reliable Measurement of Gas TURBINE METER TRZ 0 Method of operation, Construction Method of operation The TRZ 0 turbine meter is a flow meter suitable for gas measurement
More informationSingle Phase Motors Technical Datasheets
Single Phase Motors Technical Datasheets EN A dynamic, strong and ambitious Group: Orange1 Holding is an international renown Group, one of the most important European manufacturers of single-phase and
More informationSmall Signal Fast Switching Diode
Small Signal Fast Switching Diode MECHANICAL DATA Case: SOD- Weight: approx.. mg Packaging codes/options: 8/K per " reel (8 mm tape), K/box 08/K per 7" reel (8 mm tape), K/box FEATURES Silicon epitaxial
More informationSINEAX VK 636 Programmable Temperature Transmitter with PROFIBUS-PA protocol
with PROFIBUS-PA procol for installation in the terminal head of a temperature sensor DIN 79, shape B Application 00 II () G FISCO The SINEAX VK 66 is a temperature transducer for use in aumation systems
More information5 V/10 V Low Drop Voltage Regulator TLE 4266
5 /1 Low Drop oltage Regulator TLE 266 Features Output voltage 5 or 1 Output voltage tolerance ±2% 12 ma current capability ery low current consumption Low-drop voltage Overtemperature protection Reverse
More informationTYPE EMC. Thermostatic Expansion Valve
TYPE EMC Thermostatic Expansion Valve with ODF Solder or SAE Flare Connections for Refrigerants,, 4a, 404A, 502 & 507 BULLETIN --4 June 1995 The Sporlan Type EMC thermostatic expansion valve (TEV) is a
More informationHEAT CONTENT DECREASES U D R HEAT CONTENT INCREASESO. Btu/lb
Pressure (psia) LINES OF CONSTANT ENTHALPY PRESSURE P R E S S U R E R I S E S P R E S S HEAT CONTENT DECREASES U R E D R HEAT CONTENT INCREASESO P S Btu/lb Heat Content Pressure (psia) SATURATION CURVE
More informationDrive electronics pq12
Drive electronics pq12 Amplifier module with constant current controller for proportional valves Control of one solenoid Easy mounting directly on bearing rails acc. to EN 50022 Standard voltage and current
More informationAC axial compact fan
ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-7467 Mulfingen Phone +49 798 8-0 Fax +49 798 8-0 info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen County court Stuttgart HRA
More informationData Sheet, Rev. 1.1, February 2008 TLE4294GV50. Low Drop Out Voltage Regulator. Automotive Power
Data Sheet, Rev. 1.1, February 2008 TLE4294GV50 Low Drop Out Voltage Regulator Automotive Power Low Drop Out Voltage Regulator TLE4294GV50 1 Overview Features Output voltage tolerance ±4% Very low drop
More informationOverload Relays. SIRIUS 3RU1 Thermal Overload Relays. 3RU11 for standard applications. 5/46 Siemens LV 1 AO 2011
SIRIUS 3RU1 Thermal Overview 1 2 7 3 4 6 "Increased safety" type of EEx e according to ATEX directive 94/9/EC The 3RU11 thermal overload relays are suitable for the overload of explosion-proof motors with
More informationSECTION 1 - WHAT IS A BTU METER? BTU's = Flow x ΔT Any ISTEC BTU Meter System consists of the following main components:
SECTION 1 - WHAT IS A BTU METER? ISTEC BTU Meters measure energy usage by multiplying flow rate and temperature difference. As the water (or other liquid) passes through these lines, the multi-wing turbine
More informationAir Cooler Industry AC-LN 1-7 / ACA-LN 2-7 / ACAF-LN 2-7
ir ooler Industry -LN -7 / -LN -7 / F-LN -7 Symbol General The -LN -7 air cooler series can be used in all areas where either oil or water-glycol is to be cooled with air. The coolers with an axial fan
More informationSINEAX VK 626 Programmable Temperature Transmitter for RTD and TC inputs, with HART protocol
SINEAX VK 66 for RTD and TC inputs, with HART procol for installation in the terminal head of a temperature sensor DIN 79, shape B Application II () G SINEAX VK 66 is a two-wire head-mounted transmitter.
More information4HP13 PRODUCT SPECIFICATIONS 13 SEER SPLIT SYSTEM HEAT PUMP WARRANTY
4HP13 PRODUCT SPECIFICATIONS 13 S SPLIT SYSTEM HEAT PUMP FORM NO. 4HP13-100 (07/2014) R410A Refrigerant High-quality condenser coil with copper tubing and enhanced louvered fin for maximum heat transfer
More information