Eliminator Liquid line filter driers, Type DCL and DML
|
|
- Lauren Jones
- 5 years ago
- Views:
Transcription
1 MAKING MODERN LIVING POSSIBLE Eliminator Liquid line filter driers, Type DCL and DML Flare connection Solder connection (copper) REFRIGERATION & AIR CONDITIONING DIVISION Technical leaflet
2 Contents Page Introduction Features Approvals Technical data Technical data and capacities Ordering Identification Selection Selection example Design and function Dimensions and weights - Flare connections Dimensions and weights - Solder connections Conversions DKRCC.PD.E00.B. / 20H44 Danfoss A/S (AC-DSL / SKT),
3 Introduction EVR Eliminator liquid line filter driers protect refrigeration and air-conditioning systems from moisture, acids, and solid particles. With these contaminants eliminated, systems are safer from harmful chemical reactions and from abrasive impurities. There are two types of Eliminator cores. Type DML driers have a core composition of 00% Molecular Sieve, while type DCL contain 0% Molecular Sieve with 20% activated alumina. All Eliminator driers have a solid core with binding material held to an absolute minimum. Core selection is primarily based on the refrigerant oil used in the system. Eliminator type DML, with a solid core of 00% Molecular Sieve, is optimized for use with HFC refrigerants and polyolester (POE) or polyalkyl glycol (PAG) oils. Type DML driers are designed for applications requiring high water adsorption, and can be used with any manufacturer s compressor. Because type DML driers contain no activated alumina, oil additives will not be depleted. Eliminator type DCL, with a solid core of 0% Molecular Sieve and 20% activated alumina, is the drier of choice for systems with HCFC and CFC refrigerants and mineral or alkyl benzene oils. Type DCL driers are particularly suited for systems that operate at high condensing temperatures and require high drying capacity. Features The Core Type DML 00% Å Molecular Sieve core. High drying capacity minimizing the risk of acid formation (hydrolysis). Optimized for HFC refrigerants (R4a, R404A, R40A, etc.) with POE or PAG oils. Compatible with R. Will not deplete oil additives. Type DCL 0% Å Molecular Sieve with 20% activated alumina. Perfect core blend for systems that operate at high condensing temperatures and require high drying capacity. Optimized for CFC and HCFC refrigerants (R, R02, etc.) with mineral or alkyl benzene oils. Compatible with HFC s and refrigerant blends. The Shell UL approved for MWP up to 42 bar ( psig) Available with solder (copper) and flare connections. Compact cubic inches drier ideal for refrigeration and air conditioning units. Corrosion resistant powder-painted finish. Can be used in all environments including marine applications. Allows installation with any orientation provided the arrow is in the flow direction. Available in sizes from to cubic inches. The Filter 2 μm (0.00 in.) filter provides high retention with minimal pressure drop. Thermally stable up to 20 C (20 F) Approvals UL file no. SA 9 PED 9/EC - ap Danfoss A/S (AC-DSL / SKT), DKRCC.PD.E00.B. / 20H44
4 Technical data Surface and volume Acid capacity Temperature range Acid Filter capacity [oz.] DCL DCL DCL DCL 0. DCL DCL 4 0. DCL DCL to 0 C ( 40 to 0 F) Solid core surface Solid core volume Filter drier volume (shell volume) Filter drier volume (net. volume) Filter [in 2 ] [in ] [fl. oz.] [fl. oz.] DML/DCL DML/DCL DML/DCL DML/DCL DML/DCL DML/DCL DML/DCL DML/DCL..2 Technical data and capacities DML Drying and liquid capacity - Type DML R4a, R0, R404A, R, R40C, R40A ) Drying capacity is based on following moisture content test standards before and after drying: R4a: From 00 ppm W to ppm W. If drying to 0 ppm W is required, reduce stated capacities by %. R404A, R0: From 020 ppm W to 0 ppm W. R40C: From 020 ppm W to 0 ppm W. R40A: From 00 ppm W to 0 ppm W. R: From 00 ppm W to 0 ppm W in accordance with ARI ) Given in accordance with ARI 0- for t e = C ( F), t c = 0 C ( F) and Δp = 0.0 bar ( psig). Type DML02/02s DML 02.s DML0/0s DML04s DML02/02s DML 02.s DML0/0s DML04s DML0s DML02/02s DML 02.s DML0/0s DML04/04s DML0/0s DML2s DML 2.s DML/s DML4s DML/s DML/s DMLs DML0/0s DML04/04s DML0/0s DML0/0s DML0s DML09s DML4 DML444s DML4s DML4s DML49s DML04s DML0s DML09s DMLs DML9s R4a Drying capacity [lbs refrigerant] ) Liquid capacity [TR] 2 ) Max. R404A R0 R, R40C R40A F 2 F F 2 F F 2 F R4a R404A R R R40C R40A Working Pressure PS [psig] DKRCC.PD.E00.B. / 20H44 Danfoss A/S (AC-DSL / SKT),
5 Technical data and capacities ) Drying capacity is based on following moisture content test standards before and after drying: R4a: From 00 ppm W to ppm W. If drying to 0 ppm W is required, reduce stated capacities by %. R404A, R0: From 020 ppm W to 0 ppm W. R40C: From 020 ppm W to 0 ppm W. R40A: From 00 ppm W to 0 ppm W. R: From 00 ppm W to 0 ppm W in accordance with ARI 0-. R2: From ppm W to ppm W in accordance with ARI 0-. R02: From 020 ppm W to 0 ppm W in accordance with ARI ) Given in accordance with ARI 0- for t e = C ( F), t c = 0 C ( F) and Δp = 0.0 bar ( psig). DCL Drying and liquid capacity - Type DCL Type DCL02/02s DCL 02.s DCL0/0s DCL02/02s DCL 02.s DCL0/0s DCL02/02s DCL 02.s DCL0/0s DCL04/04s DCL2s DCL 2.s DCL/s DCL4s DCL/s DCL/s DCLs DCL0/0s DCL04/04s DCL0/0s DCL0/0s DCL0s DCL09s DCL4 DCL444s DCL4s DCL4s DCL49s DCL04s DCL0s DCL09s DCLs DCL9s Type DCL02/02s DCL 02.s DCL0/0s DCL02/02s DCL 02.s DCL0/0s DCL02/02s DCL 02.s DCL0/0s DCL04/04s DCL2s DCL 2.s DCL/s DCL4s DCL/s DCL/s DCLs DCL0/0s DCL04/04s DCL0/0s DCL0/0s DCL0s DCL09s DCL4 DCL444s DCL4s DCL4s DCL49s DCL04s DCL0s DCL09s DCLs DCL9s R4a R4a, R0, R404A, R40C, R40A Drying capacity [lbs refrigerant] ) Liquid capacity [TR] 2 ) Max. R404A R0 R40C R40A F 2 F F 2 F F 2 F R4a R404A R R40C R40A Working Pressure PS [psi] R, R2, R02 Drying capacity [lbs refrigerant] ) Liquid capacity [TR] 2 ) Max. Working R R2 R02 Pressure R R2 R02 PS F 2 F F 2 F F 2 F [psi] Danfoss A/S (AC-DSL / SKT), DKRCC.PD.E00.B. / 20H44
6 Ordering Flare Type Conn. Multipack Industrialpack in. mm Code no. Code no. Qty. DCL 02 DCL 02 DCL 0 DCL 0 DCL 02 DCL 0 DCL 02 DCL 0 DCL 04 DCL 2 DCL DCL 4 DCL DCL DCL 0 DCL 04 DCL 0 DCL 0 DCL 4 DCL 44 DCL 4 / / 0 0 / 0 / 0 / 2 2 / 0 / 2 2 / 9 / 0 / 2 2 / 9 / 0 / 2 2 / * Wire mesh in filter drier outlet 02Z000* 02Z0 02Z00* 02Z09 02Z002 02Z00 02Z004 02Z00 02Z00 02Z00 02Z00 02Z009 02Z00 02Z0 02Z002 02Z00 02Z004 02Z0 02Z00 02Z002 02Z00 02Z0 02Z09 02Z002 02Z00 02Z004 02Z00 02Z00 02Z00 02Z00 02Z009 02Z00 02Z0 02Z04 02Z DCL 2 2 Solder (copper) DCL Type Conn. Multipack Industrialpack Conn. Multipack Industrialpack in. Code no. Code no. Qty. mm Code no. Code no. Qty. DCL 02s DCL 02.s DCL 0s DCL 02s DCL 02.s DCL 0s DCL 02s DCL 02.s DCL 0s DCL 04s DCL 2s DCL 2.s DCL s DCL 4s DCL s DCL s DCL s DCL 0s DCL 04s DCL 0s DCL 0s DCL 0s DCL 09s DCL 44s DCL 4s DCL 4s DCL 49s DCL 04s DCL 0s DCL 09s DCL s DCL 9s / / / / * Wire mesh in filter drier outlet 02Z0* 02Z04 02Z0 02Z0 02Z4 02Z09 02Z0 02Z 02Z02 02Z02 02Z02 02Z 02Z029 02Z02 02Z0 02Z00 02Z04 02Z000 02Z00 02Z002 02Z00 02Z004 02Z00 02Z004 02Z00 02Z00 02Z00 02Z024 02Z00 02Z00 02Z0 02Z0 02Z0* 02Z04* 2 02Z0 02Z09 02Z0 02Z02 02Z02 02Z02 02Z0 02Z00 02Z02 02Z Z02* 02Z04 02Z0 02Z0 02Z4 02Z020 02Z02 02Z 02Z024 02Z02 02Z02 02Z 02Z00 02Z0 02Z0 02Z00 02Z04 02Z09 02Z09 02Z002 02Z02 02Z004 02Z Z0 02Z00 02Z00 02Z Z0 02Z00 02Z Z0 02Z020 02Z02* 02Z04* 2 02Z0 02Z020 02Z02 02Z00 02Z0 02Z9 02Z02 02Z04 2 DKRCC.PD.E00.B. / 20H44 Danfoss A/S (AC-DSL / SKT),
7 Ordering (cont.) Flare Type DML 02 DML 0 DML 0 DML 02 DML 0 DML 02 DML 0 DML 04 DML 0 DML 2 DML DML 4 DML DML DML 0 DML 04 DML 0 DML 0 DML 4 DML 44 DML 4 DML Conn. Multipack Industrialpack in. mm Code no. Code no. Qty. / / 0 0 / 0 / 0 / 2 2 / / 0 / 2 2 / 9 / 0 / 2 2 / 9 / 0 / 2 2 / * Wire mesh in filter drier outlet 02Z0* 02Z0* 02Z090 02Z0 02Z0 02Z09 02Z040 02Z04 02Z0 02Z042 02Z04 02Z044 02Z04 02Z04 02Z Z000 02Z00 02Z09 02Z00 02Z009 02Z00 02Z0* 02Z0* 02Z090 02Z0 02Z0 02Z09 02Z040 02Z04 02Z0 02Z042 02Z04 02Z044 02Z04 02Z04 02Z049 02Z00 02Z0 02Z9 02Z0 02Z09 02Z0 2 2 Solder (copper) DML Type Conn. Multipack Industrialpack Conn. Multipack Industrialpack in. Code no. Code no. Qty. mm Code no. Code no. Qty. DML 02s DML 02.s DML 0s DML 04s / DML 02s DML 02.s / DML 0s DML 04s DML 0s DML 02s DML 02.s / DML 0s DML 04s DML 0s DML 2s DML 2.s / DML s DML 4s DML s DML s DML s DML 0s DML 04s DML 0s DML 0s DML 0s DML 09s DML 44s DML 4s DML 4s DML 49s DML 04s DML 0s DML 09s DML s DML 9s * Wire mesh in filter drier outlet 02Z04* 02Z049 02Z00 02Z2 02Z0 02Z 02Z04 02Z0 02Z00 02Z0 02Z 02Z0 02Z0 02Z02 02Z0 02Z9 02Z04 02Z0 02Z0 02Z0 02Z09 02Z00 02Z00 02Z009 02Z000 02Z00 02Z002 02Z0 02Z02 02Z0 02Z04 02Z04 02Z00 02Z004 02Z0 02Z0 02Z04* 02Z049 02Z00* Danfoss A/S (AC-DSL / SKT), DKRCC.PD.E00.B. / 20H Z04 02Z0 02Z 02Z4 02Z0 02Z0 02Z0 02Z09 02Z0 02Z 02Z4 02Z 02Z Z04* 02Z049 02Z0 02Z2 02Z02 02Z 02Z0 02Z099 02Z00 02Z0 02Z 02Z09 02Z00 02Z02 02Z02 02Z9 02Z0 02Z0 02Z0 02Z0 02Z09 02Z09 02Z099 02Z009 02Z000 02Z00 02Z020 02Z0 02Z02 02Z0 02Z020 02Z09 02Z00 02Z020 02Z0 02Z020 02Z04* 02Z049 02Z0* 02Z Z0 02Z0 02Z0 02Z09 02Z0 02Z 02Z 2 4
8 Identification Example for type codes D C L 0 s Type codes Filter drier Solid core D C M Application L Liquid line Size (volume) Connection (filter connection in / of an inch increments) Connection type (blank) s 0 / 20% composite core 00% Molecular Sieve core in in in in 0 in 4 in 0 in in in. / mm / in. / mm / in. / 0 mm / 2 in. / 2 mm / in. / mm in. / (9) mm / in. / mm / in. / 2 mm Flare connection Solder connection Selection Type selection is made considering the application ) For CFC systems, DCL filter driers are recommended. In these systems, circumstances may require the use of a filter drier with acid adsorbing properties. 2 ) Use of filter driers containing activated alumina are not recommended in systems with oils containing additives. Refrigerant Oil DCL DML HFC Can be used Recommended HCFC Recommended Can be used CFC Recommended Not recommended ) Mineral or AB Recommended Can be used POE or PAG, pure Can be used Recommended POE or PAG, with additives Not recommended 2 ) Recommended Selection example Select the appropriate type (DML or DCL) based on refrigerant and oil type. Then select the dri er size based on the ad sorp tion and liquid ca pac i ty required. a. Amount of charge: lbs R4a at t L = F To dry lbs R4a at F from 00 to 0 ppm moisture, a DML is necessary. b. Cooling capacity: Q e =. TR To obtain a mass flow corresponding to. TR cooling capacity with a DML filter drier, a / inch connection must be cho sen. Larger connections can be chosen in accordance with the liquid line dimension. c. Result DML or DML s can be used. If the initial moisture content is very small or a planned change of the filter drier is considered, a smaller filter drier size can be chosen. Type DML 02/02s DML 02.s DML 0/0s DML 04s DML 2s DML 2.s DML /s DML 4s DML /s DML /s DML s R4a Drying capacity [lbs refrigerant] ) Liquid capacity [tons] 2 ) Max. R404A R0 R, R40C R40A F 2 F F 2 F F 2 F R4a R404A R R R40C R40A Working Pressure PS [psig] 0 0 DKRCC.PD.E00.B. / 20H44 Danfoss A/S (AC-DSL / SKT),
9 Design and function DML / DCL 0 DML / DCL 0, 4 DML / DCL 0 DML / DCL 0,. Inlet 2. Spring. Solid core 4. Polyester mat. Perforated plate. Seal cap, flare connection. Seal cap, solder connection DML / DCL 0, The relatively large diameter of the filter drier means that the liquid flow velocity is suitably low and the pressure drop minimal. Powder formation is eliminated because the solid core grains are bonded and cannot move against each other. Dimensions and weights Flare connections Type A A A 2 L D D 2 Weight DCL/DML 02 in lbs DCL/DML 0 in lbs Danfoss A/S (AC-DSL / SKT), DKRCC.PD.E00.B. / 20H44 9
10 Dimensions and weights (cont.) Flare connections Type A A A 2 L D D 2 Weight DCL/DML 02 in lbs DCL/DML 0 in lbs Type A A A 2 L D D 2 Weight DCL/DML 02 in lbs DCL/DML 0 in lbs DCL/DML 04 in lbs DML 0 in lbs DCL/DML 2 in lbs DCL/DML in lbs DCL/DML 4 in lbs DCL/DML in lbs DCL/DML in lbs Type A A A 2 L D D 2 Weight DCL/DML 0 in lbs DCL/DML 04 in lbs DCL/DML 0 in lbs DCL/DML 0 in lbs DCL/DML 4 in lbs DCL/DML 44 in lbs DCL/DML 4 in lbs 0 DKRCC.PD.E00.B. / 20H44 Danfoss A/S (AC-DSL / SKT),
11 Dimensions and weights (cont.) Solder connections Type A A A 2 B L D D 2 Weight DCL/DML 02s in lbs DCL/DML 02.s in lbs DCL/DML 0s in lbs DCL/DML 04s in lbs Type A A A 2 B L D D 2 Weight DCL/DML 02s in lbs DCL/DML 02.s in lbs DCL/DML 0s in lbs DML 04s in lbs DML 0s in lbs Type A A A 2 B L D D 2 Weight DCL/DML 02s in lbs DCL/DML 02.s in lbs DCL/DML 0s in lbs DCL/DML 04s in lbs DML 0s in lbs DCL/DML 2s in lbs DCL/DML 2.s in lbs DCL/DML s in lbs DCL/DML 4s in lbs DCL/DML s in lbs DCL/DML s in lbs DCL/DML s in lbs Danfoss A/S (AC-DSL / SKT), DKRCC.PD.E00.B. / 20H44
12 Dimensions and weights (cont.) Solder connections Type A A A 2 B L D D 2 Weight DCL/DML 0s in lbs DCL/DML 04s in lbs DCL/DML 0s in lbs DCL/DML 0s in lbs DCL/DML 0s in lbs DCL/DML 09s in lbs DCL/DML 44s in lbs DCL/DML 4s in lbs DCL/DML 4s in lbs DCL/DML 49s in lbs DCL/DML 04s in lbs DCL/DML 0s in lbs DCL/DML 09s in lbs DCL/DML s in lbs DCL/DML 9s in lbs Conversions (lbs of refrigerant (Initial PPM of water - Final PPM of water)) Drops of water = 0 See ARI standard 0- for recommended initial and final PPM values for different refrigerants. 2 DKRCC.PD.E00.B. / 20H44 Danfoss A/S (AC-DSL / SKT),
Uni-Flow Filter Drier
STNDRD Uni-Flow Filter Drier The filter driers of series DTG are used in refrigeration system with unidirectional flow to absorb moisture and acid in the system and to filter out the impurities. FETURES
More informationSight Glass and Moisture Indicator Virginia KMP Series LDE
Sight Glass and Moisture Indicator Virginia KMP LDE DIMENSIONS: Dimension Dimension Connection Type "A" "B" Inches (mm) Inches (mm) LDE2 1/4 Male X 1/4 Male 2-7/8 72 1-7/ 36 LDE2S 1/4 Sweat X 1/4 Sweat
More informationHigh pressure sight glass (PS = 52 bar) Types SGP N, SGP I and SGP X
MAKING MOERN IVING POSSIBE ata sheet igh pressure sight glass (PS = 2 bar) Types SGP N, SGP I and SGP X Sight glasses are used to indicate:. The condition of the refrigerant in the liquid line of the plant.
More informationSolenoid valve Types EVR 2 - EVR 40
Data sheet Solenoid valve s EVR 2 - EVR 40 EVR is a direct or servo operated solenoid valve for liquid, suction, and hot gas lines with HCFC and HFC refrigerants. EVR valves are supplied complete or as
More informationMAKING MODERN LIVING POSSIBLE. Thermostatic expansion valve Type TUB/TUBE and TUC/TUCE REFRIGERATION AND AIR CONDITIONING.
MAKING MODERN LIVING POSSIBLE Thermostatic expansion valve Type B/BE and C/CE REFRIGERATION AND AIR CONDITIONING Technical leaflet Thermostatic expansion valve, type B/BE and C/CE Contents Page Introduction........................................................................................
More informationThermostatic expansion valves TUB/TUBE and TUC/TUCE
MAKING MODERN LIVING POSSIBLE Technical brochure Thermostatic expansion valves B/BE and C/CE www.danfoss.com Thermostatic expansion valve, type B/BE and C/CE Contents Page Introduction........................................................................................
More informationAccumulators Virginia KMP Suction Line Accumulators
Accumulators Virginia KMP Suction Line Accumulators The Virginia KMP suction line accumulator's purpose is to prevent excessive quantities of liquid refrigerant and oil from returning to the compressor.
More informationSolenoid valves Type EVR 2 g 40 NC/ NO New EVR 6 with Steel cover design
MAKING MODERN LIVING POSSIBLE Technical brochure Solenoid valves EVR 2 g 40 NC/ NO New with Steel cover design EVR is a direct or servo operated solenoid valve for liquid, suction, and hot gas lines with
More informationThermostatic expansion valves TUA/TUAE
MAKING MODERN LIVING POSSIBLE Technical brochure Thermostatic expansion valves A/AE www.danfoss.com Thermostatic expansion valves, type A/AE Contents Page Introduction... Features... Standard range...
More informationSolenoid valves Type EVUL
Data sheet Solenoid valves EVUL EVUL solenoid valves are designed to fit into compact refrigeration systems. Available in servo operated versions they can be applied in liquid, suction, and hot gas lines.
More informationSolenoid valve Types CSV 2 - CSV 22 (NC) and solenoid coil
Data sheet Solenoid valve s CSV 2 - CSV 22 (NC) and solenoid coil CSV is a direct or servo-operated solenoid valve for liquid, suction, and hot gas lines with fluorinated refrigerants. CSV valves are for
More informationAIR CONDITIONING COMMERCIAL REFRIGERATION HEAT PUMP STANDARD PRODUCT CATALOGUE
AIR CONDITIONING COMMERCIAL REFRIGERATION HEAT PUMP STANDARD PRODUCT CATALOGUE CA-STD- SUMMARY SANHUA Strive for perfection, Pursuit of excellence 4 WAY REVERSING VALVE SHF SERIES 4 WAY REVERSING VALVE
More informationProduct Data. CNPVP, CNRVP, CNPVT, CNRVT, CNPVU, CNRVU Evaporator Coil N Coil Cased and Uncased Upflow, Downflow
CNPVP, CNRVP, CNPVT, CNRVT, CNPVU, CNRVU Evaporator Coil N Coil Cased and Uncased Upflow, Downflow Product Data CN(P,R)VP CN(P,R)VT (Transition) A06008 A06007 This vertical design N -coil is a furnace
More informationHEAT CONTENT DECREASES U D R HEAT CONTENT INCREASESO. Btu/lb
Pressure (psia) LINES OF CONSTANT ENTHALPY PRESSURE P R E S S U R E R I S E S P R E S S HEAT CONTENT DECREASES U R E D R HEAT CONTENT INCREASESO P S Btu/lb Heat Content Pressure (psia) SATURATION CURVE
More information45 Flare Fittings. Copper Flare Bonnets and Gaskets. Copper Flare. Copper Flare Gaskets. * C Dimension: Copper Flare Seal Bonnet +/ 1/64
Copper Flare Bonnets and Gaskets Copper Flare Seal Bonnets Part Number Size Flare A (in) B (in) C (in) Box Qty Wt(lb) B1 3 A 04737 3/16 0.31 0.16 0.16 25 0.001 B1 4 A 00414 1/4 0.36 0.22 0.22 100 0.001
More information4 Way Reversing Valve
STANDARD 4 Way Reversing Valve SHF series four-way reversing valves are applicable for heat pump systems such as central, unitary and room air conditioners to realize switching between cooling mode and
More informationDM70 Hand-Held Dewpoint Meter for Spot-Checking Applications
DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications The Vaisala DRYCAP Hand-Held Dewpoint Meter DM70 offers accurate and fast measurement for industrial dewpoint applications, such as compressed
More informationEND4X, ENW4X, ENA4X. Product Specifications VERTICAL EVAPORATOR COILS ALL N COIL MODELS CASED N COILS UNCASED N COILS ENA4X WARRANTY*
ENVIRONMENTALLY SOUND REFRIGERANT VERTICAL EVAPORATOR COILS ALL N COIL MODELS 1½ thru 5 Tons Available for environmentally sound R 410A systems Copper tube / aluminum fin N coil with latest high tech fin
More informationProduct Data. CNPHP, CNRHP Evaporator Coil N Coil --- Cased Horizontal CNPHP / CNRHP
CNPHP, CNRHP Evaporator Coil N Coil --- Cased Horizontal Product Data 06005 This horizontal design N -coil is an evaporator coil designed to provide the highest standards of reliability and durability.
More informationGlide Effect on Performance
Glide Effect on Performance ASHRAE, January 2016 Bachir Bella Regis Leportier* ASERCOM Azeotropic Mixtures The azeotropic (refrigerant) mixtures are usually binary mixtures that behave like a pure fluid
More informationProduct Data. CAPVU Evaporator Coil A Coil --- Uncased Upflow, Downflow CAPVU
CAPVU Evaporator Coil A Coil --- Uncased Upflow, Downflow Product Data CAPVU A06002 The CAPVU evaporator coils incorporate proven standards for reliable system operation and performance throughout the
More informationProduct Data CNPVP, CNPVT, CNPVU, CNRVU EVAPORATOR COIL N COIL - CASED AND UNCASED UPFLOW, DOWNFLOW
CNPVP, CNPVT, CNPVU, CNRVU EVPORTOR COIL N COIL - CSED ND UNCSED UPFLOW, DOWNFLOW Product Data CNPVP CNPVT (Transition) CN(P,R)VU 06008 06007 06004 This vertical design N -coil is a furnace coil designed
More informationENH4X. Product Specifications HORIZONTAL EVAPORATOR COILS ALL CASED N COIL MODELS WARRANTY*
ENVIRONMENTALLY SOUND REFRIGERANT ENH4X Product Specifications HORIZONTAL EVAPORATOR COILS ALL CASED N COIL MODELS 2 thru 5 Tons Available for environmentally sound R 410A systems Copper tube / aluminum
More informationAIR COOLED CONDENSING UNIT
NEW EVOLUTION SERIES AIR COOLED CONDENSING UNIT OUTDOOR AIR COOLED CONDENSING UNIT ORIGINAL MANUFACTURED EQUIPMENT NEW EVOLUTION 7 & 8 SERIES BA-506-5 AUS Evolution Air Cooled Condensing Unit Series Content
More informationAIR CONDITIONING STANDARD COMMERCIAL REFRIGERATION HEAT PUMP PRODUCT CATALOGUE
AIR CONDITIONING COMMERCIAL REFRIGERATION HEAT PUMP STANDARD PRODUCT CATALOGUE CA-STD-EN-R1013 SUMMARY SANHUA Strive for perfection, Pursuit of excellence 04 4 WAY REVERSING VALVE SHF SERIES 08 4 WAY
More informationCFC, HCFC free, GWP zero thermal insulation in the form of tubes, sheets, coils and self-adhesive tape, a Flexible Elastomeric Foam product complying
CFC, HCFC free, GWP zero thermal insulation in the form of tubes, sheets, coils and self-adhesive tape, a Flexible Elastomeric Foam product complying with the European standard EN. EUROBATEX is a closed
More informationASPT Series. Multi-Position, Internal TXV. Air Handler 1½ to 5 Tons
Series Multi-Position, Internal TXV Product Features Internal factory-installed thermal expansion valves for cooling and heat pump applications Direct drive, multi-speed ECM blower motor All-aluminum evaporator
More informationR- 410A R-22 Size (tons) Shipping Weight (lbs) WLAU184AA 1-1/ WLAU182AA 1-1/ WLAU244AA. Model /2
EVAPORATOR COILS A COIL - UNCASED R- 410A or R- 22 SYSTEMS 1 1/2 5 Tons WLAU Use of the AHRI Certified TM Mark indicates a manufacturer s participation in the program. For verification of certification
More informationSolkane 410 Thermodynamics
SOLVAY FLUOR SOLKANE - INFORMATION SERVICE Solkane 410 Thermodynamics SOLVAY FLUOR Technical Service - Refrigerants - Product Bulletin no.: T/09.04/04/E P.O. Box 0 Phone +49/511/857-653 3000 Hannover Fax
More informationTYPE EMC. Thermostatic Expansion Valve
TYPE EMC Thermostatic Expansion Valve with ODF Solder or SAE Flare Connections for Refrigerants,, 4a, 404A, 502 & 507 BULLETIN --4 June 1995 The Sporlan Type EMC thermostatic expansion valve (TEV) is a
More informationTESTING of AGGREGATES for CONCRETE
TESTING of AGGREGATES for CONCRETE The properties of the aggregates affect both the fresh and hardened properties of concrete. It is crucial to know the properties of the aggregates to be used in the making
More informationCase 5 Manual Selection of Water Cooled Condenser and Water Cooler
Case 5 Manual Selection of Water Cooled Condenser and Water Cooler Copy Right By: Thomas T.S. Wan ) Nov. 19, 2010 All Rights Reserved Case Background: This case is to demonstrate the use of manufacturer
More informationNP-175FR. High luminance of multi-functional epoxy contrast with copper
New: 2018/09/12 Flame retardant copper clad laminate NP-175FR Characteristics Unit Conditioning Typical Values SPEC Test Method Volume resistivity MΩ-cm C-96/35/90 5 x10 9 ~ 5x10 10 10 6 2.5.17 Surface
More informationOUTDOOR UNITS. Introduction YMF-C. Introduction. Refrigerant
Introduction Introduction Refrigerant R407C R Series Y series (Heat Pump) R series (Air-cooling) Y series ( Only) Y series (Heat Pump) R series (Air-cooling) Y series ( Only) OUTDOOR UNITS Model Name -YMF-C
More information3 Port, 2-Ton Outdoor Heat Pump
Job Name: Tag# Submittal Data Sheet 3 Port, 2-Ton Outdoor Heat Pump 3MXS24NMVJU Efficiency SEER EER HSPF Non-Ducted 17.9 12.7 12.5 Ducted 14 9.7 8.2 Mixed 15.95 11.2 10.35 Performance Cooling (Btu/hr)
More informationZHEJIANG FOTECH INTERNATIONAL CO., LTD.
Company Profile Zhejiang Fotech International Co., Ltd is a leading manufacturer and supplier of Refrigerant Gases, Fluor Polymer and Fluor Rubber. Products that are inventoried include:r22, R32, R134A,
More informationElement description. Multipass test in compliance ISO Contaminant ISO MTD. A - Microfibre
Style FZ Stainless Steel Pressure filter Technical data element Style In-Line filter: FZ 00-0 FZP 0 FZ 0 FZP 6 FZX 0 Manifold mounting: FZ 0 FZM 0 Max. working pressure: 700 bar Max. working pressure:
More informationP303 Pressure Regulator
P0 Pressure Regulator Minimize Sudden Downstream Load Change Wide Pressure Ranges Integral Monitoring The BelGAS P0 and P0H gas pressure reducing regulators are available with a true monitor regulator,
More informationHydrothermal damaging of molecular sieve and how to prevent it
Hydrothermal damaging of molecular sieve and how to prevent it Peter B. Chr. Meyer Natural Gas Marketing Manager CECA / ATOFINA Paris La Défense France Paper presented at the Gas Processors Association
More informationDuctless Split Systems Floating Air
Ductless Split Systems Floating Air PURCHASER P.O. # DATE PROJECT LOCATION ENGINEER ARCHITECT SUBMITTED BY FOR APPROVAL FOR REFERENCE ITEM PLAN DESIGNATION QUANTITY COOLING BTU/H VOLTAGE FRIEDRICH MODEL
More informationEFFICIENT 13 SEER HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz
ENVIRONMENTALLY SOUND REFRIGERANT N4H3 Performance Series Product Specifications EFFICIENT 13 SEER HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase,
More informationMade in Italy HOSE REELS CATALOGUE TECHNOLOGY FOR FLUIDYNAMICS. No. E14/A1
Made in Italy HOSE REELS CATALOGUE TECHNOLOGY FOR FLUIDYNAMICS No. E14/A1 The complete range of our products is presented in the specific catalogues: HOSE REELS CATALOGUE No. E14/A2 HOSE REELS CATALOGUE
More informationTHE ENERGY 68,SAVING TDVI. exible Combine Modular 24, 26, 28, 30, 32, 34, 36, 38, 40, 42, 44 HP 60, 62, 64, 66 HP
I N V E RT E R ion Range exible Combine Modular TDV I TDV I TDV I INVERTER INVERTER INVERTER 14, 16, 18, 20, 22 HP TDV I 24, 26, 28, 30, 32, 34, 36, 38, 40, 42, 44 HP INVERTER INVERTER INVERTER TDV I INVERTER
More informationENVIRONMENTALLY SOUND R 410A REFRIGERANT
ENVIRONMENTALLY SOUND REFRIGERANT N4H3 Performance Series Product Specifications EFFICIENT 13 SEER HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase,
More informationPressure Measurement Single-range transmitters for general applications
Siemens AG 07 Overview Function SITRANS LH00 Transmitter for hydrostatic level U const. p U I EM Sensor Connection for auxiliary power supply Vent pipe with humidity filter Protective conductor connection/
More informationAIR COOLED CONDENSING UNIT
EVOLUTION SERIES AIR COOLED CONDENSING UNIT OUTDOOR AIR COOLED CONDENSING UNIT ORIGINAL MANUFACTURED EQUIPMENT Evolution Series BA-503-3 AUS Evolution Air Cooled Condensing Unit Series Content Page Explanation
More informationMultilayer Ceramic Chip Capacitors
HIGH VOLTAGE SERIES JARO high voltage series Multilayer Ceramic Capacitors are constructed by depositing alternative layers of ceramic dielectric materials and internal metallic electrodes, by using advanced
More informationDATA SHEET POSITIVE TEMPERATURE COEFFICIENT AC/DC POWER SUPPLY SMD0603 series
Product specification November 05, 201 V.0 DATA SHEET AC/DC POWER SUPPLY series RoHS compliant & Halogen free 2 Positive Temperature Coefficient (PTC) Data Sheet Description The 0603 series provides miniature
More informationBLC Series - Basic Compact Pressure Sensor Series. Introduction
Sensors CoBeam TM Technology. The device provides a high output Features & Applications... signal at a low operating voltage and reduces the overall supply Standard Pressure Ranges... voltage while maintaining
More informationFlow rates to 750 l/min
FP Maximum pressure 0 bar Flow rates to 70 l/min Technical data Filter housing (Materials) ead: Cast iron (chemical heat treatment) ousing: Steel (chemical heat treatment) Bypass valve: AISI L (FP 0-0)
More informationTurbine Meter TRZ 03 PRODUCT INFORMATION. Reliable Measurement of Gas
Turbine Meter TRZ 0 PRODUCT INFORMATION Reliable Measurement of Gas TURBINE METER TRZ 0 Method of operation, Construction Method of operation The TRZ 0 turbine meter is a flow meter suitable for gas measurement
More informationNPG-151 IPC-4101C//127
New: 2014/04/30 Glass cloth base epoxy resin flame retardant copper clad laminate NPG-151 FEATURES Halogen, antimony, and red phosphorous free Flammability meets UL 94 V-0 Excellent thermal resistance
More informationThree-Way Mixing Valve. with or without presetting, for heating and cooling systems
with or without presetting, for heating and cooling systems escription HEIMEIER three-way, with or without presetting, for mixing volume flows in heating and cooling systems, made of gunmetal, with protection
More informationTable of Contents. Oil Furnace, Low Profile Highboy, OH6 Series 6. Oil Furnace, Low Profile Highboy, OH8 Series 7. Oil Furnace, Lowboy, OL5 Series 8
Table of Contents PAGE N. Air Conditioning Data Sheet Dimensional Coil Table Coil Part Nomenclature - Thermo Pride Brand il Furnace, ow Profile Highboy, H6 Series 6 il Furnace, ow Profile Highboy, H8 Series
More informationFlow rates to 750 l/min
FP Maximum pressure 0 bar Flow rates to 70 l/min Technical data Filter housing (Materials) ead: Cast iron (chemical heat treatment) ousing: Steel (chemical heat treatment) Bypass valve: AISI L (FP 00-0)
More informationSTAINLESS STEEL FILTER
STINLSS STL FILTR Style FZ Stainless Steel Pressure filter Technical data Style In-Line filter: FZ 00-0 FZP 0 FZ 0 FZP 6 FZX 0 Manifold mounting: FZ 0 FZM 0 Max. working pressure: 700 bar Max. working
More informationPressure Measurement. Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level 2/27
Overview Siemens AG 011 Function s are for measuring the liquid levels in wells, tanks, channels and dams. Diaphragm p Sensor U const. U + (brown) I EM I -1 (blue) 0, U B s are submersible sensors for
More informationRestoration of Eureka Clock Serial Number 4793
Page 1 Restored Eureka 4793 Restoration of Eureka Clock Serial Number 4793 Page 2 Restored Eureka 4793 Photos by kind permission of the owner. A short movement with ceramic skeletonised dial. The dial
More informationIBV Series C Carbon Steel Inverted Bucket Vertical Steam Trap
Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without
More informationDirect-operated 2/2-way solenoid valves Type EV210B
Data sheet Direct-operated 2/2-way solenoid valves Type EV20B EV20B covers a wide range of direct-operated 2/2-way solenoid valves for universal use. EV20B is a very robust valve program with high performance
More informationEXECUTIVE SUMMARY. especially in last 50 years. Industries, especially power industry, are the large anthropogenic
EXECUTIVE SUMMARY Introduction The concentration of CO 2 in atmosphere has increased considerably in last 100 years, especially in last 50 years. Industries, especially power industry, are the large anthropogenic
More informationBasic Aggregates Study Guide
Basic Aggregates Study Guide General Conversions 1) There are pounds in one ton. 2) There are grams in one pound. 3) One kilogram consists of grams. 4) The linear distance that one station covers is feet.
More informationIBV Series Z Alloy Steel Inverted Bucket Vertical Steam Trap
Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without
More informationNPGN-150R. FEATURES Halogen, antimony, and red phosphorous free Flammability meets UL 94 V-0 NAN YA PLASTICS CORPORATION
NAN YA PLASTICS CORPORATION Issured : 2010-09-01 flame retardant copper clad laminate Flammability meets UL 94 V-0 Excellent long term reliability UV blocking type NPGN-150R Reactive type flame retardants
More informationREPAIR PARTS. AVPTC Air Handler. This manual is to be used by qualified technicians only. This manual replaces RP-775E.
REPAIR PARTS AVPTC Air Handler AVPTC24B14AA AVPTC24B14AB AVPTC24B14AC AVPTC30C14AA AVPTC30C14AB AVPTC36C14AA AVPTC36C14AB AVPTC42D14AA AVPTC42D14AB AVPTC42D14AC AVPTC48C14AA AVPTC48C14AB AVPTC48D14AA AVPTC48D14AB
More informationDM70 Hand-Held Dewpoint Meter for Spot-Checking Applications
DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications The Vaisala DRYCAP Hand-Held Dewpoint Meter DM70 offers accurate and fast measurement for industrial dewpoint applications, such as compressed
More informationProppant Conductivity Analysis 40/70 Black Ceramic
Proppant Conductivity Analysis 40/70 Black Ceramic Page 1 of 6 Background: Fracture conductivity tests were performed on the 40/70 ceramic proppant sample. The tests were performed at 250 F and 2,000 psi,
More informationG-FIRE GROOVED FITTINGS
G-FIRE GROOVED FITTINGS 29 Pictorial Table of Contents Figure 510 90 Cast Elbows Page 32 Figures 212 & 312 22 1 2 Elbows Page 35 Figure 501 45 Cast Elbows Page 32 Figures 211 & 311 11 1 4 Elbows Page 36
More informationMaximum pressure 420 bar Flow rate to 152 l/min. 560 bar. 140 l/min. Flow rate l/min FMM 050 1/2 1,50 3/4 1,00. Δp bar 0,50 0,00 FHA 051 1,50 1,00
FMM 00 Maximum pressure 0 bar Flow rate to l/min FHA 0 Maximum pressure 60 bar Flow rate to 0 l/min Technical data FMM 00 Filter housing (Materials) Head: Cast iron (chemical heat treatment) Housing: Steel
More informationFlow rates to 485 l/min
FB Maximum pressure 0 bar Flow rates to 8 l/min Technical data Filter housing (Materials) ead: Cast iron (chemical heat treatment) ousing: Steel (chemical heat treatment) Bypass valve: Steel Check valve:
More informationERT320 BIOSEPARATION ENGINEERING CHROMATOGRAPHY
ERT320 BIOSEPARATION ENGINEERING CHROMATOGRAPHY CHROMATOGRAPHY Week 9-10 Reading Assignment: Chapter 7. Bioseparations Science & Engineering, Harrison, R; Todd, P; Rudge, S.C and Petrides, D,P CHROMATOGRAPHY
More informationReturn fi lters. MPI series. Maximum working pressure up to 1 MPa (10 bar) - Flow rate up to 3000 l/min
Return fi lters series Maximum working pressure up to MPa (0 bar) Flow rate up to 000 l/min 0 Return fi lters Introduction FILTER SIZING INDEX CALCULATION CORRECTIVE FACTOR Page Introduction Calculation
More informationNP-180R. U.L. file number E98983
New: 2018/09/12 Flame retardant copper clad laminate NP-180R High Tg 175 (DSC) Excellent dimensional stability through-hole reliability Excellent electrical, chemical and heat resistance properties IPC-4101E
More informationAIR BREATHER FILTERS. Temperature from -25 C to +100 C
IR RETHER FILTERS The comprehensive series of breather filters makes it possible to meet all market demands. Metal and plastic styles suitable for use on mobile equipment are available. The function of
More informationDispensers/Dilutors REPIPET DISPENSERS REPIPET DILUTORS PIPETS OUR BEST ALL GLASS DISPENSERS! OUR LOWEST PRICED DISPENSERS! VIRTUALLY UNBREAKABLE!
S E L E C T I O N G U I D E Dispensers/Dilutors OUR BEST DISPENSERS! REPIPET DISPENSERS VIRTUALLY UNBREAKABLE! OUR BEST ALL GLASS DISPENSERS! OUR LOWEST PRICED DISPENSERS! Dispenser Reagent Product Volume
More informationPREPARATION OF ACTIVATED CARBON FROM PULP AND PAPER MILL WASTES TO BE TESTED FOR THE ADSORPTION OF VOCS
PREPARATION OF ACTIVATED CARBON FROM PULP AND PAPER MILL WASTES TO BE TESTED FOR THE ADSORPTION OF VOCS A. GREGÓRIO *, A. GARCIA-GARCIA #, D. BOAVIDA *, I. GULYURTLU * AND I. CABRITA * * Department of
More informationInverter Multi-Split System
Inverter MultiSplit System Specifications Inverter MultiSplit Fan coil unit Fan Coil Unit Model RAVMS3KCVT RAVMS3KCVT RASMS3KCVT RAVM22S3KCVT RAVM24S3KCVT Standard Cooling Capacity (btu/hr) 9,212 12,624
More informationCOMPLEX CARBON-MINERAL SORBENTS FROM COMMON CLAY
1 COMPLEX CARBON-MINERAL SORBENTS FROM COMMON CLAY Authors: S. Cosin 1., C. A. Pinto 2, P. de Souza Santos 1, F.R. Valenzuela Díaz 1. 1) University of São Paulo, Polytechnic School, Materials and Metallurgical
More informationChemistry Instrumental Analysis Lecture 31. Chem 4631
Chemistry 4631 Instrumental Analysis Lecture 31 High Performance Liquid Chromatography (HPLC) High Performance Liquid Chromatography (HPLC) High Performance Liquid Chromatography (HPLC) Solvent Delivery
More informationA Review on Performance Improvement of Adsorber Bed by Effective Heating and Cooling
A Review on Performance Improvement of Adsorber Bed by Effective Heating and Cooling 1 Ameya C. Lohokare, 2 V. N. Kapatkar 1,2 Sinhgad College of Engineering Email: 1 ameya.c.lohokare@gmail.com, 2 vnkapatkar.scoe@sinhgad.edu
More informationFigure 4-1: Pretreatment schematic
GAS TREATMENT The pretreatment process consists of four main stages. First, CO 2 and H 2 S removal stage which is constructed to assure that CO 2 would not exceed 50 ppm in the natural gas feed. If the
More informationAIR PREPARATION. ELECTRONICALLY CONTROLLED PRESSURE REGULATING VALVE (PROPORTIONAL PRESSURE REGULATING VALVE) SERIES control
AIR PREPARATION ELECTRONICALLY CONTROLLED PRESSRE REGLATING ALE (PROPORTIONAL PRESSRE REGLATING ALE) SERIES control Description Abb. Port size Recommended Type Data Sheet No. flow (l/min)* airfit tecno
More informationHD 049 HD 069 HD 172 HD 319 HD 419 HD 619. Operating pressure up to 8700 psi Nominal flow rate up to gpm us
H i g h P re s s u re i l t e r K i t s H 049 H 069 H 172 H 319 H 419 H 619 Operating pressure up to 8700 psi Nominal flow rate up to 118.9 gpm 40.95-3us e s c r i p t i o n pplication In the high pressure
More informationGB5BM Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Air Handler WARRANTY
TECHNICAL SPECIFICATIONS GB5BM Series Air Handler 13 SEER Residential System 18,000-60,000 Btuh (Heat Pump & Air Conditioner) The GB5BM Series of air handlers, when combined with our heat pump or air conditioner,
More information331 Low & Medium Pressure filters
Low & Medium Pressure fi lters LMP 00-0 & 0- series Maximum pressure up to 60 bar - Flow rate up to 70 l/min Low & Medium Pressure filters FILTER SIZING The correct filter sizing have to be based on the
More informationBrushless DC Variable Speed Compressor Technical Data Sheet
R134a V DC VARIABLE SPEED Brushless DC Variable Speed Compressor Technical Data Sheet General Information Compressor Part Number (Stationary) CASCADE0005 (140 per pallet) Compressor Part Number (Mobile)
More informationSubmittals. Advanced Series 1U09ES2VHA / AW09ES2VH* 1U12ES2VHA / AW12ES2VH* 1U18ES2VHA / AW18ES2VH* 1U24ES2VHA / AW24ES2VH* Rev.
Submittals Advanced Series 1U09ES2VHA / AW09ES2VH* 1U12ES2VHA / AW12ES2VH* 1U18ES2VHA / AW18ES2VH* 1U24ES2VHA / AW24ES2VH* C US Intertek For more information visit us: www.haierductless.com www.haierductlesshelp.com
More informationReturn fi lters. FRI series. Maximum pressure up to 20 bar - Flow rate up to 1500 l/min. Return fi lters
Return fi lters FRI series Maximum pressure up to 0 bar - Flow rate up to 500 l/min 9 Return fi lters FILTER SIZING The correct filter sizing have to be based on the variable pressure drop depending by
More information2. be aware of the thermal properties of materials and their practical importance in everyday life;
MODULE 3: THERMAL AND MECHANICAL PROPERTIES OF MATTER GENERAL OBJECTIVES On completion of this Module, students should: 1. understand the principles involved in the design and use of thermometers; 2. be
More informationEffect of Magnetic field on Hydrocarbon refrigerant
Effect of Magnetic field on Hydrocarbon refrigerant Sagar Patil 1, Nahush Kamble 2, Jay Kadam 3, Saurabh Patil 4,Ajaj Attar 5 1 B.E., Mechanical Department, Smt. Kashibai Navale College of Engg, sagarnpatil.sp@gmail.com
More informationChapter 12 Tex-617, Determining Chloride in Concrete
Chapter 12 Tex-617, Determining Chloride in Contents: Section 1 Overview... 12-2 Section 2 Apparatus... 12-3 Section 3 Preparing Solutions... 12-4 Section 4 Procedures... 12-5 Section 5 Calculations...
More informationnufacturing Company, L.P San Felipe, Suite 500
REPAIR PARTS AVXC20 Inverter Air Conditioners AVXC200241AA AVXC200241AB AVXC200241AC AVXC200361AA AVXC200361AB AVXC200361AC AVXC200481AA AVXC200481AB AVXC200481AC AVXC200601AA AVXC200601AB AVXC200601AC
More informationAlumina & Pseudoboehmite & Molecular sieve
Activated Alumina & Activated alumina, Pseudoboehmite & Molecular sieve Pseudoboehmite & Molecular sieve Quality and advanced Technology About XiangRun Catalyst & Adsorbent Why Choose Xiangrun? Zibo XiangRun
More informationBrushless DC Variable Speed Compressor Technical Data Sheet
R134a V DC VARIABLE SPEED Brushless DC Variable Speed Compressor Technical Data Sheet General Information Compressor Part Number (Stationary) CASCADE0006 (140 per pallet) Compressor Part Number (Mobile)
More informationRESPONSE OF A RADON CHARCOAL CANNISTER TO CLIMATIC AND RADON VARIATIONS IN THE INTE RADON CHAMBER. A. Vargas, X. Ortega, I.
RESPONSE OF A RADON CHARCOAL CANNISTER TO CLIMATIC AND RADON VARIATIONS IN THE INTE RADON CHAMBER A. Vargas, X. Ortega, I. Serrano Institut de Tècniques Energètiques (INTE), Universitat Politècnica de
More informationmandata_us :43 Pagina 83 (1,1) FHB 82
8 FHB SERIES FHB Working pressure 4600 psi Style S Style B Style T Style D B B B B D.I. D.I. D.I. D.I. A A A A 8 Technical data Filter body ( M a t e r i a l s ) Head: Cast iron (chemical heat tre a t
More informationFlow rates to 475 l/min
FMP Maximum pressure 0 bar Flow rates to 7 l/min Technical data PRSSUR FILTR Filter housing (Materials) ead: Cast iron (chemical heat treatment) ousing: Steel (chemical heat treatment) Bypass valve: Brass
More informationE 094 E 103 E 143. Tank top mounting Connection up to G1 Nominal flow rate up to 135 l/min e
R e t u r n F i l t e rs E 094 E 103 E 143 Tank top mounting Connection up to G1 Nominal flow rate up to 135 l/min 20.30-5e D e s c r i p t i o n Application In the return line circuits of hydraulic systems.
More informationHigh Pressure fi lters. FMP 039 series. Maximum pressure up to 110 bar - Flow rate up to 80 l/min. High Pressure fi lters
High Pressure fi lters FMP 09 series Maximum pressure up to 0 bar Flow rate up to 80 l/min 7 High Pressure fi lters FILTER SIZING The correct filter sizing have to be based on the variable pressure drop
More informationConductivity sensor for hygienic applications
Conductivity sensor for hygienic applications Type 8221 can be combined with Perfect for demanding applications in the hygienic industry (CIP and SIP compatible) Variants available for usage over a wide