1 Simplified Workflow and Improved Confidence in Screening Methods on Time of Flight Mass Spectrometry Steve Preece MS Business Manager Waters Wilmslow 2016 Waters Corporation 1
2 Overview Use of high resolution MS (Q-Tof) for suspect screening Key criteria for identification Case study with Xevo G2-XS QTof What else can I do with the data? Using ion mobility MS for screening 2016 Waters Corporation 2
3 Advantages of accurate mass screening? Over recent years high resolution mass spectrometry has gained in popularity as a screening tool in the food and environmental sector Ability to perform non-targeted analysis The freedom to measure compounds without prior compound specific tuning Ability to perform full spectral analysis Providing greater insight into the composition of a complex sample Ability to perform historical (retrospective) data review The capability of performing structural elucidations of unknowns or suspected compounds Ability to screen for larger number of compounds and adducts Compared to QqQ based screening Increased specificity & selectivity in complex matrices Sensitivity in line with Regulations. Accurate mass, diagnostic fragment ions HRMS strongly competes with classical tandem mass spectrometry in the field of quantitative multiresidue methods (e.g., pesticides and veterinary drugs). It is one of the most promising tools when moving towards nontargeted approaches... Kaufman A., Anal BioAnal Chem 2011 Dec Waters Corporation 3
4 HRMS UNIFI Screening Key Benefits Are these compounds in my sample? Screening How much is in my sample? Quantitation Scientific Library RT, MW, Structure, Fragments & CCS Workflows Simplify data review Quan/Qual Workflow MS E Single Analysis Alternately Tof MRM Ultimate Sensitivity What is the difference between my sample and another one? Binary Compare/Multivariant Analysis Statistical Comparison of Samples Comparison What else is in my sample? Elucidation Discovery Tools Anything Interesting? Elucidation tools Identify what is interesting 2016 Waters Corporation 4
5 Atrazine: TQ Identification from RT and ion ratios > > Waters Corporation 5
6 Advantages of Non-Target ToF Screening over MRM Target Screening MRM #1 MRM #4 MRM #6 MRM #3 MRM #5 MRM #7 MRM # Waters Corporation 6
7 Accurate Mass Screening Acquiring full MS spectral data See everything unlike specific MRM acquisition Using 20mDa extraction window for mass chromatograms Specificity from accurate mass data Acquiring MS E data Molecular weight and fragment data from the same run Using multiple data features to confirm or identify Accurate mass, retention time, fragments, adducts, isotopes 2016 Waters Corporation 7
8 Xevo G2-XS QTof : MS E MS E High and low energy spectra Precursor and fragment ions Single acquisition Data independent acquisition Data automatically aligned Requires partial LC peak resolution Links associated precursors and fragments 2016 Waters Corporation 8
9 Atrazine: HRMS 2016 Waters Corporation 9
10 Mass accuracy alone Number of Identified Pesticides (mass accuracy alone) ppm 3ppm 1ppm. provides insufficient specificity 2016 Waters Corporation 10
11 Retention time.. Number of Identified Pesticides (using Rt and m/z (5ppm)) min window - better than 1ppm + reduced risk of false negatives ± ± min ± 0.4 min ± 0.5 min no Rt. helps reduce false detects 2016 Waters Corporation 11
12 Fragment ions Number of Identified Pesticides (Rt, m/z and at least 1 fragment) ± 0.25 min ± 0.4 min ± 0.5 min no Rt. provide additional specificity 2016 Waters Corporation 12
13 Pesticide-Based Installation Specifications 2016 Waters Corporation 13
14 UNIFI: Raw data is processed once Tabulated in oracle database Data is componentised Spectral features are already associated Background ions are excluded Extracted Spectrum Component Spectrum 2016 Waters Corporation 14
15 Real Life Example: XEVO G2 XS Pesticide Screening Application Solution using Xevo G2-XS QTof Sample supplied as extracted by the customer Sample information approx 20 compounds >10 ppb approx 10 compounds < 10ppb What else can you see? (strawberry pomace) Identified, at least 1 fragment ion Identified, no fragment ion(s) 2016 Waters Corporation 15
16 Non-Targeted Screening with Xevo G2-XS QTof Higher instrument sensitivity means : Lower screening detection limits Better confidence in data Better isotope match scores Better ability to detect adducts Greater ability to detect fragments More pesticides being detected and they are now being detected with fragments Fragments are considered to be confirmatory Other MS information is used as additional evidence 2016 Waters Corporation 16
17 Example 3: Non targeted Screening Are these compounds in my sample? Screening How much is in my sample? Quantitation What is the difference between my sample and another one? Comparison What else is in my sample? Elucidation (strawberry pomace) January 2014 Analysis of more samples requested ( Sample information approx 20 compounds >10 ppb approx 10 compounds < 10ppb What else can you see? 2016 Waters Corporation 17
18 Qualitative Screening: Binary Compare Spinach Red = Blank/Reference Blue = Unknown Green = Difference Region of interest 2016 Waters Corporation 18
19 Qualitative Screening: Binary Compare Spinach Control sample Highlight Masses of Interest Send to Batch Elucidation Tool Reference sample 2016 Waters Corporation 19
20 Beyond Resolution 2016 Waters Corporation 20
21 Ion Mobility-Mass Spectrometry Why ion mobility for complex samples? How does it work? Orthogonal separations Calculation of collision cross section What effect does it have on analyses? Drug metabolism data Pesticide screening data 2016 Waters Corporation 21
22 Ion Mobility Spectrometry LC-IMS-MS IMS provides greater peak capacity than LC-MS alone Reveals compounds that would have been missed Provides greater coverage for sample profiling IMS generates cleaner data Removes background ions from spectra Allows easier and faster data interpretation IMS reduces errors in compound confirmation Additional collision cross section (CCS) information Reduces false positives and negatives for screening 2016 Waters Corporation 22
23 The Basic Principal Ions are driven through a tube by an electric field Velocity of ions is determined by mass and charge Motion of the ions is resisted by a drift gas Resistance is determined by size (mass) and shape of the ion N 2 Ions are separated based on their charge, mass and shape With chromatography and MS, this provides additional separation power 2016 Waters Corporation 23
24 LC-IM-MS IMS MS LC time 2016 Waters Corporation 24
25 IMS Orthogonal Separation The ability to see more Resolution of isomers Cleaner spectra Collision Cross Section IMS drift time CCS Additional identification point Matrix independent System independent 2016 Waters Corporation 25
26 What is CCS? Important differentiating characteristic of an ion Chemical structure (mass, size) Dimensional information (shape) Precise physicochemical property of an ion 2016 Waters Corporation 26
27 WIV ISP Study: SYNAPT/Vion Comparison for Pesticides Consistent CCS values Different instruments in different countries 5 Synapt WIV ISP/Vion IMS Q ToF Comparison April % CCS Difference Acetamiprid Azoxystrobin Bromuconazole II Carbetamide Carbofuran Chlorbromuron Chloridazon (Pyrazon) Clethodim I Clethodim I fgt Clethodim II Clethodim II fgt Cyromazine DEET Demeton-S-methyl-sulfone Dichlorvos Diethofencarb fgt Disulfoton-sulfone Diuron Ethoprophos Fenamiphos sulphone Fenoxycarb Fenoxycarb fgt Fenpropimorph Fenpyroximat Flutriafol Formetanate Fosthiazate Furathiocarb Heptenophos Hexazinone Indoxacarb Isoxaben Linuron Mesotrione Metalaxyl Methabenzthiazuron Metobromuron Metolachlor Metribuzin Mevinphos trans Nitenpyram Oxadiazon pethoxamid phenthoate Pirimicarb Primicarb-desmethyl fgt* Propamocarb propargite Prosulfocarb Pymetrozine Pyraclostrobin Pyridaben Pyridaben fgt 1 Pyridate Pyriproxifen Simazine Spinosad Spirodiclofen Spiroxamine II Tebuconazole tepraloxydim Thiacloprid Thiodicarb Thiophanate-methyl Triasulfuron Triflumuron Trinexapac-ethyl Triticonazole Vamidothion Pesticide Axis Title 2016 Waters Corporation 27
28 MS E HDMS E MS E High and low energy spectra Precursor and fragment ions Single acquisition Data independent acquisition Data automatically aligned Requires partial LC peak resolution Links associated precursors and fragments HDMS E IMS separation in front of MS E Can separate ions that co-elute in LC Cleaner spectra due to mobility resolution 2016 Waters Corporation 28
29 Spectral Cleanup Pentanochlor at 1 µg.kg -1 courtesy of Dr. Jens Luetjohann, GALAB, Germany, Waters Corporation 29
30 Screening Detection of low level compounds in complex samples Requirement for efficient separation Need not to miss peaks Confident confirmation of presence or absence of targets No false negatives No false positives Identification Points -Exact mass -Retention time -Fragment ions -Isotope peaks Increased likelihood of false positives with large library Matrix and system dependent Can be lost near limit of detection Use additional identifier - CCS 2016 Waters Corporation 30
31 Mandarin EU PT Sample 8 Expected to be detected 29 Observed using a wide screen 2016 Waters Corporation 31
32 Results summary for EU RL proficiency sample FV-13 8 Expected to be detected False +ve False -ve 9 observed after 10ppm accurate mass and fragment filtering 8 observed with 2% CCS filter 2016 Waters Corporation 32
33 Vion and UNIFI: Providing routine ion mobility Seamlessly from sample to answers Just press START Simply Acquire Get to the Answers 2016 Waters Corporation 33
34 UNIFI screening workflow for Vion courtesy of Dr. Jens Luetjohann, GALAB, Germany, Waters Corporation 34
35 UNIFI screening workflow for Vion courtesy of Dr. Jens Luetjohann, GALAB, Germany, Waters Corporation 35
36 Sensitivity: mg/kg pentanochlor in tomato extract HDMS E courtesy of Dr. Jens Luetjohann, GALAB, Germany, Waters Corporation 36
37 Conclusions Targeted, suspect and unknown screening require sensitivity and selectivity for successful outcomes Xevo G2-XS QTof Data processing and review have evolved Beyond 2D extracted ion chromatograms Using all of the data for confirmation CCS adds another dimension for separation and identification Matrix and system independent Additional confidence in decisions 2016 Waters Corporation 37
38 Acknowledgements US FDA Boethell Lab GALAB, Germany WIV-ISP, Belgium Thank you for your attention Any questions Waters Corporation 38
Quantitation of High Resolution MS Data Using UNIFI: Acquiring and Processing Full Scan or Tof-MRM (Targeted HRMS) Datasets for Quantitative Assays
: Acquiring and Processing Full Scan or Tof-MRM (Targeted HRMS) Datasets for Quantitative Assays Mark Wrona, Jayne Kirk, and Yun Alelyunas Waters Corporation, Milford, MA, USA APPLICATION BENEFITS Ability
More informationApplying MRM Spectrum Mode and Library Searching for Enhanced Reporting Confidence in Routine Pesticide Residue Analysis
PO-CON1768E Applying MRM Spectrum Mode and Library Searching for Enhanced Reporting Confidence in Routine Pesticide ASMS 2017 TP-194 David Baker 1, Christopher Titman 1, Neil Loftus 1, Jonathan Horner
More informationAdvanced Data Acquisition and Data Processing Workflows to Identify, Quantify and Confirm Pesticide Residues
Advanced Data Acquisition and Data Processing Workflows to Identify, Quantify and Confirm Pesticide Residues André Schreiber 1 and Lauryn Bailey 2 1 AB SCIEX Concord, Ontario (Canada); 2 AB SCIEX Framingham,
More informationFORENSIC TOXICOLOGY SCREENING APPLICATION SOLUTION
FORENSIC TOXICOLOGY SCREENING APPLICATION SOLUTION A purpose-built collection of the best-inclass components for forensic toxicology Whether you re challenged to present reliable and secure forensic sample
More informationTheory and Practical Consequences.
Theory and Practical Consequences. Number of hits depending on reachable mass accuracy 250 hits @ ±10 ppm 137 hits @ ±5 ppm 78 hits @ ±3 ppm 29 hits @ ±1 ppm 3 hits @ ±0.1 ppm 1 hit @ ± 0.05 ppm Intens.
More informationMultiresidue Analysis of 100 Pesticides in Food Samples by LC/Triple Quadrupole Mass Spectrometry Application
Multiresidue Analysis of Pesticides in Food Samples by LC/Triple Quadrupole Mass Spectrometry Application Food Safety Authors Imma Ferrer and E. Michael Thurman Pesticide Residue Research Group University
More informationUNIFI - Targeted and Untargeted Screening MS Software
UNIFI - Targeted and Untargeted Screening MS Software Dr David Hardy Senior Product Manager Mass Spectrometry Software 2011 Waters Corporation 1 Waters System Solutions - Available with UNIFI Biopharmaceutical
More informationA Workflow Approach for the Identification and Structural Elucidation of Impurities of Quetiapine Hemifumarate Drug Substance
A Workflow Approach for the Identification and Structural Elucidation of Impurities of Quetiapine Hemifumarate Drug Substance Michael D. Jones, Marian Twohig, Karen Haas, and Robert S. Plumb Waters Corporation,
More informationMassHunter TOF/QTOF Users Meeting
MassHunter TOF/QTOF Users Meeting 1 Qualitative Analysis Workflows Workflows in Qualitative Analysis allow the user to only see and work with the areas and dialog boxes they need for their specific tasks
More informationOverview. Introduction. André Schreiber AB SCIEX Concord, Ontario (Canada)
Quantitation and Identification of Pharmaceuticals and Personal Care Products (PPCP) in Environmental Samples using Advanced TripleTOF MS/MS Technology André Schreiber AB SCIEX Concord, Ontario (Canada)
More informationPesticides in Cannabis
LCMS-8040 Application Pesticides in Cannabis Jeff Dahl, 1 Julie Kowalski, 2 Jason Zitzer, 3 and Gordon Fagras 3 1 Shimadzu Scientific Instruments; Columbia, Maryland 2 Restek Corporation; Bellefonte, Pennsylvania
More informationLC-HRMS: Challenges for Routine Implementation
Joint EURL pesticides meeting October 23 rd -25th, 2013 Almeria Spain LC-HRMS: Challenges for Routine Implementation Richard J. Fussell Food and Environment Research Agency (York, UK) www.fera.defra.gov.uk
More informationAgilent MassHunter Profinder: Solving the Challenge of Isotopologue Extraction for Qualitative Flux Analysis
Agilent MassHunter Profinder: Solving the Challenge of Isotopologue Extraction for Qualitative Flux Analysis Technical Overview Introduction Metabolomics studies measure the relative abundance of metabolites
More informationAlmería 23 rd -25 th October th Joint Workshop of the European Union Reference Laboratories for Residues of Pesticides
General European Commission Proficiency Test Scheme EURL-FV Scientific Group Samples and Protocol INFORMATION EUPT Web Page Data Analysis Reports 1 2 3 4 5 ACTIVITY DATE Publishing the Calendar and Matrix
More informationYun W. Alelyunas, Mark D. Wrona, Russell J. Mortishire-Smith, Nick Tomczyk, and Paul D. Rainville Waters Corporation, Milford, MA, USA INTRODUCTION
Quantitation by High Resolution Mass Spectrometry: Using Target Enhancement and Tof-MRM to Achieve Femtogram-level On-column Sensitivity for Quantitation of Drugs in Human Plasma Yun W. Alelyunas, Mark
More informationFood & Environmental. Overview. Introduction. Method Details. André Schreiber and Yun Yun Zou SCIEX, Concord, Ontario, Canada
Food & Environmental Comprehensive Quantitation and Identification of Pesticides in Food Samples using LC-MS/MS with Scheduled MRM, Fast Polarity Switching, and MS/MS Library Searching André Schreiber
More informationFUTURE CONFIRMATORY CRITERIA
FUTURE CONFIRMATORY CRITERIA Revision CD 2002/657 Marco Blokland, Bjorn Berendsen, Hans Mol, Leen van Ginkel, Saskia Sterk REVISION 2 Revision 2002/657 EU Commission has explicitly asked for a revision
More informationHigher Confidence in Identification with QTRAP LC/MS/MS Systems when Screening and Quantifying Pesticides in Fruit and Vegetable Samples
Higher Confidence in Identification with QTRAP LC/MS/MS Systems when Screening and Quantifying Pesticides in Fruit and Vegetable Samples André Schreiber AB SCIEX, Concord, Ontario, Canada Figure 1. Ion
More informationRapid Pesticide Screening and Identification Using the High Resolution All Ions MS/MS Technique
Rapid Pesticide Screening and Identification Using the High Resolution All Ions MS/MS Technique Application Note Food Safety Authors Bernhard Wüst and Thomas Glauner Agilent Technologies GmbH Waldbronn
More informationPesticideScreener. Innovation with Integrity. Comprehensive Pesticide Screening and Quantitation UHR-TOF MS
PesticideScreener Comprehensive Pesticide Screening and Quantitation Innovation with Integrity UHR-TOF MS The Challenge of Comprehensive Pesticide Residue Analysis The use of pesticides to reduce crop
More informationLC-MS/MS multiresidue method used for pesticides analysis in fruits and vegetables
LC-MS/MS multiresidue method used for pesticides analysis in fruits and vegetables 1st International Symposium on Recent Advances in Food Analysis 5-7 ovember 2003, Prague Didier RTELLI, Patrick EDDER,
More informationTargetScreener. Innovation with Integrity. A Comprehensive Screening Solution for Forensic Toxicology UHR-TOF MS
TargetScreener A Comprehensive Screening Solution for Forensic Toxicology Innovation with Integrity UHR-TOF MS TargetScreener Get the Complete Picture Forensic laboratories are frequently required to perform
More informationQualitative and Quantitative Analysis of Pesticides in Horse Feed Matrix Using Orbitrap MS
Qualitative and Quantitative Analysis of esticides in Horse Feed Matrix Using rbitrap M laf cheibner and Maciej Bromirski, Thermo Fisher cientific, Bremen, Germany Application Note 573 Key Words Exactive
More informationMetabolic Phenotyping Using Atmospheric Pressure Gas Chromatography-MS
Metabolic Phenotyping Using tmospheric Pressure Gas hromatography-ms Vladimir Shulaev, 2 Ghaste Manoj, 2,3 Steven Lai, 1 arolina Salazar, 2 Nobuhiro Suzuki, 2 Janna rossley, 2 Feroza Kaneez oudhury, 2
More informationScreening Validation Report 1
EURL for Cereals and Feeding stuff National Food Institute Technical University of Denmark Appendix 4 Screening Validation Report 1 Screening of pesticide residues in cereals by UPLC-TOF (QuEChERS method)
More informationKey Words Q Exactive, Accela, MetQuest, Mass Frontier, Drug Discovery
Metabolite Stability Screening and Hotspot Metabolite Identification by Combining High-Resolution, Accurate-Mass Nonselective and Selective Fragmentation Tim Stratton, Caroline Ding, Yingying Huang, Dan
More informationMulti-residue GC-MS analysis. Richard Fussell CSL York, UK
Multi-residue GC-MS analysis Richard Fussell CSL York, UK e-mail: r.fussell@csl.gov.uk Outline of Presentation Background Gas Chromatography Mass Spectrometry - Options Capabilities and Applications Summary
More informationApplication News. No. C154. Applying MRM Spectrum Mode and Library Searching for Enhanced Reporting Confidence in Routine Pesticide Residue Analysis
LAAN-A-LM-E124 Application Liquid Chromatography Mass Spectrometry Applying MRM Spectrum Mode and Library Searching for Enhanced Reporting Confidence in Routine Pesticide Residue Analysis David R. Baker
More informationTHE IMPLEMENTATION OF A SCREENING WORKFLOW FOR ION MOBILITY QUADRUOPOLE TIME-OF-FLIGHT MASS SPECTROMETRIC ANALYSIS OF PFOS ISOMERS
THE IMPLEMENTATION O A SCREENING WORKLOW OR ION MOBILITY QUADRUOPOLE TIME-O-LIGHT MASS SPECTROMETRIC ANALYSIS O POS ISOMERS Ken Rosnack ken_rosnack@waters.com Ingrid Ericson Jogsten and Bert van Bavel
More informationOverview. Introduction. Method Details. André Schreiber and Yun Yun Zou AB SCIEX, Concord, Ontario, Canada
Comprehensive Quantitation and Identification of Pesticides in Food Samples using LC-MS/MS with Scheduled MRM, Fast Polarity Switching, and MS/MS Library Searching André Schreiber and Yun Yun Zou AB SCIEX,
More informationOverview. Introduction
Comprehensive Quantitation and Identification of Pesticides in Food Samples Using the SCIEX UltraLC 100 and the SCIEX QTRAP 4500 System André Schreiber SCIEX, Concord, Ontario, Canada Overview Liquid Chromatography
More informationMassHunter Software Overview
MassHunter Software Overview 1 Qualitative Analysis Workflows Workflows in Qualitative Analysis allow the user to only see and work with the areas and dialog boxes they need for their specific tasks A
More informationSimplified Approaches to Impurity Identification using Accurate Mass UPLC/MS
Simplified Approaches to Impurity Identification using Accurate Mass UPLC/MS Marian Twohig, Michael D. Jones, Dominic Moore, Peter Lee, and Robert Plumb Waters Corporation, Milford, MA, USA APPLICATION
More informationDETERMINATION OF PESTICIDES IN FOOD USING UPLC WITH POLARITY SWITCHING TANDEM QUADRUPOLE LC/MS/MS
DETERMINATION OF PESTICIDES IN FOOD USING UPLC WITH POLARITY SWITCHING TANDEM QUADRUPOLE LC/MS/MS Peter Hancock 1, Cristiana C. Leandro 2,3, Brendan J. Keely 2 and Richard J. Fussell 3 1 Waters Corporation,
More informationOverview. Introduction. André Schreiber 1 and Yun Yun Zou 1 1 AB SCIEX, Concord, Ontario, Canada
LC-MS/MS Based Strategy for the Non-Targeted Screening of an Unlimited Number of Contaminants in Food Using the AB SCIEX TripleTOF 5600 System and Advanced Software Tools André Schreiber 1 and Yun Yun
More informationDetermination of pesticides in baby food by UHPLC/MS/MS using the Agilent 1290 Infinity LC system and the Agilent 6460 triple quadrupole LC/MS
Determination of pesticides in baby food by UHPLC/MS/MS using the Agilent 1290 Infinity LC system and the Agilent 6460 triple quadrupole LC/MS Application Note Food Authors Gerd Vanhoenacker, Frank David,
More informationMulti-residue analysis of pesticides by GC-HRMS
An Executive Summary Multi-residue analysis of pesticides by GC-HRMS Dr. Hans Mol is senior scientist at RIKILT- Wageningen UR Introduction Regulatory authorities throughout the world set and enforce strict
More informationAnalysis of Pesticides in Citrus Oil Using a Shimadzu GCMS-TQ8030. No. GCMS No. SSI-GCMS-1404
Gas Chromatograph Mass Spectrometer No. GCMS-1404 Analysis of Pesticides in Citrus Oil Using a Shimadzu GCMS-TQ8030 Introduction Contamination of consumer products with pesticides is a growing concern
More informationUtility of H-SRM to Reduce Matrix Interference in Food Residue Analysis of Pesticides by LC-MS/MS Using the TSQ Quantum Discovery
Application Note: 3 Utility of H-SRM to Reduce Matrix Interference in Food Residue Analysis of Pesticides by LC-MS/MS Using the TSQ Quantum Discovery Yoko Yamagishi, Thermo Fisher Scientific, C-2F 3-9
More informationWADA Technical Document TD2003IDCR
IDENTIFICATION CRITERIA FOR QUALITATIVE ASSAYS INCORPORATING CHROMATOGRAPHY AND MASS SPECTROMETRY The appropriate analytical characteristics must be documented for a particular assay. The Laboratory must
More informationAgilent TOF Screening & Impurity Profiling Julie Cichelli, PhD LC/MS Small Molecule Workshop Dec 6, 2012
1 Agilent TOF Screening & Impurity Profiling Julie Cichelli, PhD LC/MS Small Molecule Workshop Dec 6, 2012 Review: Technology for Accurate Mass Analysis: TOF LC/MS Mass measurements accurate to several
More informationAgilent All Ions MS/MS
Agilent All Ions MS/MS Workflow Overview A Determine fragment ions for LC/MS Quant method B Develop final Quant method Develop LC/MS Qualitative Analysis method Process data with Find by Formula Build
More informationThe Emergence of Benchtop Tandem Quadrupole Mass Spectrometers as a Routine Tool in Quantitative GC/MS/MS Applications
The Emergence of Benchtop Tandem Quadrupole Mass Spectrometers as a Routine Tool in Quantitative GC/MS/MS Applications Doug Stevens Waters Corp. Introduction The range of GC/MS instrument types has expanded
More informationScreening Method validation of Pesticide Residues in Cereals using G-QTOF and exact mass library
Screening Method validation of Pesticide Residues in Cereals using G-QTOF and exact mass library Mette Erecius Poulsen and Tommy Cederberg Licht EURL workshop, Stuttgart, 30 September 2015 EURL-CF and
More informationTriumphs and Challenges of High-Resolution Mass Spectrometry in Comprehensive Residue Screens
Triumphs and Challenges of High-Resolution Mass Spectrometry in Comprehensive Residue Screens Florida Department of Agriculture Mark Crosswhite, Ph.D. outline ur Goal identify and quantify quickly and
More informationA Rapid Approach to the Confirmation of Drug Metabolites in Preclinical and Clinical Bioanalysis Studies
A Rapid Approach to the Confirmation of Drug Metabolites in Preclinical and Clinical Bioanalysis Studies APPLICATION BENEFITS Regulatory guidelines and recommendations place a greater emphasis on the detection
More informationDetermination of Pesticide Multiresidues in Apple, Pear and Grape using modified QuEChERS and analysis by LC-QTOF MS
Determination of Pesticide Multiresidues in Apple, Pear and Grape using modified QuEChERS and analysis by LC-QTOF MS Application Note Authors Renato Zanella, Juliana S. Munaretto, and Manoel L. Martins
More informationSensitive and Repeatable Analysis of Pesticides in QuEChERS Extracts with APGC-MS/MS
Sensitive and Repeatable Analysis of Pesticides in QuEChERS Extracts with APGC-MS/MS Dominic Roberts, 1 Sara Stead, 1 and Jennifer A. Burgess 2 1 Waters Corporation, Manchester, UK 2 Waters Corporation,
More informationA Case of Pesticide Poisoning: The Use of a Broad-Scope Tof Screening Approach in Wildlife Protection
A Case of Pesticide Poisoning: The Use of a Broad-Scope Tof Screening Approach in Wildlife Protection George Keenan 1, Anna Giela 1, Michael Taylor 1, Jennifer Watson 1, Eleanor Riches 2, James Morphet
More informationQuantitative and Qualitative Confirmation of Pesticides in Beet Extract Using a Hybrid Quadrupole-Orbitrap Mass Spectrometer
Quantitative and Qualitative Confirmation of Pesticides in Beet Extract Using a Hybrid Quadrupole-Orbitrap Mass Spectrometer Charles Yang and Dipankar Ghosh, Thermo Fisher Scientific, San Jose, CA Olaf
More informationAll Ions MS/MS: Targeted Screening and Quantitation Using Agilent TOF and Q-TOF LC/MS Systems
All Ions MS/MS: Targeted Screening and Quantitation Using Agilent TOF and Q-TOF LC/MS Systems Technical Overview Introduction All Ions MS/MS is a technique that is available for Agilent high resolution
More informationScreening of pesticides residues by the time of flight analyzer (ToF) : Myth or reality?
Screening of pesticides residues by the time of flight analyzer (ToF) : Myth or reality? Laure Joly & Vincent Hanot WIV-ISP, Juliette Wytsmanstraat 14, 15 Brussel The passengers pesticides are requested......
More informationPure Chromatography. Food Safety Applications. Abstract. Introduction
Food Safety Applications Mitigating Matrix Effects: Examination of Dilution, QuEChERS, and Calibration Strategies for LC-MS/MS Analysis of Pesticide Residues in Diverse Food Types Abstract By Julie Kowalski,
More informationCharles Yang, Dipankar Ghosh, Jonathan Beck Thermo Fisher Scientific, San Jose, CA, USA
Utilization of High Resolution LC-MS for Screening and Quantitative Analysis of Pesticides in Food Matrix using a Q Exactive Benchtop Orbitrap Platform Charles Yang, Dipankar Ghosh, Jonathan Beck Thermo
More informationHigh Efficiency, Broad Scope Screening of Pesticides Using Gas Chromatography High Resolution Orbitrap Mass Spectrometry
High Efficiency, Broad Scope Screening of Pesticides Using Gas Chromatography High Resolution Orbitrap Mass Spectrometry Dominic Roberts,1 Hans Mol,2 Marc Tienstra,2 Cristian Cojocariu,1 and Paul Silcock1
More informationIdentification and Characterization of an Isolated Impurity Fraction: Analysis of an Unknown Degradant Found in Quetiapine Fumarate
Identification and Characterization of an Isolated Impurity Fraction: Analysis of an Unknown Degradant Found in Quetiapine Fumarate Michael D. Jones, Xiang Jin Song, Robert S. Plumb, Peter J. Lee, and
More informationDate ACCURATE-MASS DATABASE FOR SCREENING OF PESTICIDE RESIDUES IN FRUITS AND VEGETABLES BY GAS CHROMATOGRAPHY TIME-OF-FLIGHT MASS SPECTROMETRY
Date ACCURATE-MASS DATABASE FOR SCREENING OF PESTICIDE RESIDUES IN FRUITS AND VEGETABLES BY GAS CHROMATOGRAPHY TIME-OF-FLIGHT MASS SPECTROMETRY In practice, target analysis approach (analysing 1-4 of GC
More informationPerforming Peptide Bioanalysis Using High Resolution Mass Spectrometry with Target Enhancement MRM Acquisition
Performing Peptide Bioanalysis Using High Resolution Mass Spectrometry with Target Enhancement MRM Acquisition Yun Wang Alelyunas, Mark D. Wrona, and Nick Tomczyk Waters Corporation, Milford, MA, USA GOAL
More informationThe new Water Screening PCDL
The new Water Screening PCDL Content and integration in suspect and non-target screening Dr. Thomas Glauner Senior LC/MS Applications Scientist EMEA Market Development Team 1 Accurate mass screening and
More informationA Strategy for an Unknown Screening Approach on Environmental Samples Using HRAM Mass Spectrometry
A Strategy for an Unknown Screening Approach on Environmental Samples Using HRAM Mass Spectrometry Olaf Scheibner, 1 Patrizia van Baar, 2 Florian Wode, 2 Uwe Dünnbier, 2 Kristi Akervik, 3 Jamie Humphrie,
More informationQuan/Qual Analyses. Unmatched Confidence for. Thermo Scientific Q Exactive Orbitrap LC-MS/MS System. Identify Quantify Confirm
26.1645 165.91 33.267 Thermo Scientific Q Exactive rbitrap LC-MS/MS System Unmatched Confidence for Quan/Qual Analyses Identify Quantify Confirm Quanfirmation \ kwän-f r-'m -shän\ n 1 : the ability to
More informationApplication Note LCMS-116 What are we eating? MetaboScape Software; Enabling the De-replication and Identification of Unknowns in Food Metabolomics
Application Note LCMS-116 What are we eating? MetaboScape Software; Enabling the De-replication and Identification of Unknowns in Food Metabolomics Introduction Determining the structure of secondary metabolites
More informationdynamic MRM for pesticide analysis
The power of fast separation and dynamic MRM for pesticide analysis based on 1290/6460QQQ Dr. Volker Gnau Produkt Spezialist LCMS Page 1 3.) Quantitative analysis of pesticides (smrm) Chromatographic hi
More informationSUSPECT AND NON-TARGET SCREENING OF ORGANIC MICROPOLLUTANTS IN WASTEWATER THROUGH THE DEVELOPMENT OF A LC-HRMS BASED WORKFLOW
SUSPECT AND NON-TARGET SCREENING OF ORGANIC MICROPOLLUTANTS IN WASTEWATER THROUGH THE DEVELOPMENT OF A LC-HRMS BASED WORKFLOW Pablo Gago-Ferrero Laboratory of Analytical Chemistry Department of Chemistry
More informationNew Dynamic MRM Mode Improves Data Quality and Triple Quad Quantification in Complex Analyses
New Dynamic MRM Mode Improves Data Quality and Triple Quad Quantification in Complex Analyses Technical Overview Authors Abstract Peter Stone, Thomas Glauner, Frank Kuhlmann, Tim Schlabach and Ken Miller
More informationRapid and Accurate Forensics Analysis using High Resolution All Ions MS/MS
Rapid and Accurate Forensics Analysis using High Resolution All Ions MS/MS Application Note Forensic Toxicology Authors Martin Josefsson, and Markus Roman National Board of Forensic Medicine Linköping,
More informationMaking Sense of Differences in LCMS Data: Integrated Tools
Making Sense of Differences in LCMS Data: Integrated Tools David A. Weil Agilent Technologies MassHunter Overview Page 1 March 2008 How Clean is our Water?... Page 2 Chemical Residue Analysis.... From
More informationLászló Tölgyesi LC/MS scientist EFSC Demo Group. International Symposium on Food Safety and Quality: Applications of Nuclear and Related Techniques
Minimizing matrix effects in multiresidue pesticide analysis using a new sensitivity-enhanced triple quadrupole instrument in combination with extensive sample dilution László Tölgyesi LC/MS scientist
More informationA Strategy for an Unknown Screening Approach on Environmental Samples using HRAM Mass Spectrometry
A Strategy for an Unknown Screening Approach on Environmental Samples using HRAM Mass Spectrometry O. Scheibner, 1 P. van Baar, 2 F. Wode, 2 U. Dünnbier, 2 K. Akervik, 3 J. Humphries, 3 M. Bromirski 1
More informationAnalysis of Pesticides in Baby Foods Using a Triple-Quadrupole GC/MS/MS
PO-CONE Analysis of Pesticides in Baby Foods Using a Pittcon 01 -P Laura Chambers, Richard Whitney, Ph.D., Nicole M. Lock, Zhuangzhi Max Wang, Ph.D., Clifford M. Taylor; Shimadzu Scientific Instruments,
More informationStephen McDonald and Mark D. Wrona Waters Corporation, Milford, MA, USA INT RO DU C T ION. Batch-from-Structure Analysis WAT E R S SO LU T IONS
Chemical Intelligence in UNIFI: Enhancing in-silico Decision Making to Provide Confident and Accurate Results for Metabolite Identification Experiments Stephen McDonald and Mark D. Wrona Waters Corporation,
More informationAgilent MassHunter Quantitative Data Analysis
Agilent MassHunter Quantitative Data Analysis Presenters: Howard Sanford Stephen Harnos MassHunter Quantitation: Batch and Method Setup Outliers, Data Review, Reporting 1 MassHunter Quantitative Analysis
More informationWorkflow Using Hyphenated Mass Spectrometry Techniques
Pesticide Analysis Workflow Using Hyphenated Mass Spectrometry Techniques Chinkai (Kai) Meng, Ph.D. Senior Applications Chemist Wilmington, Delaware USA chin_meng@agilent.com com February 12, 2009 Page
More informationExploring the Benefits and Potential of ikey Microfluidic Chromatography and Time-of-Flight Mass Spectrometry for Pesticide Residue Analysis
Exploring the Benefits and Potential of ikey Microfluidic Chromatography and Time-of-Flight Mass Spectrometry for Pesticide Residue Analysis Michael McCullagh, 1 Severine Goscinny, 2 Vincent Hanot, 2 Richard
More informationIdentification and Quantitation of Pesticides in Chamomile and Ginger Extracts Using an Agilent 6460 Triple Quadrupole LC/MS system with Triggered MRM
Identification and Quantitation of Pesticides in Chamomile and Ginger Extracts Using an Agilent 646 Triple Quadrupole LC/MS system with Triggered MRM Application Note Authors Thomas Glauner Agilent Technologies,
More informationThe Agilent 6545 Q-TOF LC/MS System THE ANSWERS YOU NEED: BETTER, FASTER, EASIER
The Agilent 6545 Q-TOF LC/MS System THE ANSWERS YOU NEED: BETTER, FASTER, EASIER THE AGILENT 6545 Q-TOF LC/MS SYSTEM FASTER ANSWERS BETTER MEASUREMENTS EASIER HIGH PERFORMANCE RESULTS The new 6545 Q-TOF
More informationAgilent 6400 Series Triple Quadrupole Users Workshop. MH QQQ Users workshop 2/21/2014 1
Agilent 6400 Series Triple Quadrupole Users Workshop 1 Agilent 6400 Series Triple Quadrupole Users Workshop QQQ Method Development and Optimization MassHunter Quantitation: Batch and Method setup QC s,
More informationLirui Qiao, 1 Rob Lewis, 2 Alex Hooper, 2 James Morphet, 2 Xiaojie Tan, 1 Kate Yu 3
Using Natural Products Application Solution with UNIFI for the Comparison of the Chemical Ingredients of Shuanghuanglian Oral Drink from Two Different Manufacturers Lirui Qiao, 1 Rob Lewis, 2 Alex Hooper,
More informationDie Nadel im Heuhaufen
Die Nadel im Heuhaufen Workflow zur Identifizierung unerwarteter Komponenten in LC Q-Tof Daten Umwelt & Lebensmittel Seminar Tour Andreas Reimann Produktspezialist LC-MS Agilent Technologies Instrumentation
More informationMulti-stage Mass Spectrometry up to MS 4 on a QTof System
Valerie Koppen, 1 Russell Mortishire-Smith, 2 Filip Cuyckens 1 1 Janssen R&D, Beerse, Belgium 2 Waters Corporation, Wilmslow, United Kingdom APPLICATION BENEFITS This application note illustrates how multi-stage
More informationAB SCIEX SelexION Technology Used to Improve Mass Spectral Library Searching Scores by Removal of Isobaric Interferences
AB SCIEX SelexION Technology Used to Improve Mass Spectral Library Searching s by Removal of Isobaric Interferences Differential Mobility Used as a Tool to Address Selectivity Challenges Adrian M. Taylor
More informationAutomated and accurate component detection using reference mass spectra
TECHNICAL NOTE 72703 Automated and accurate component detection using reference mass spectra Authors Barbara van Cann 1 and Amit Gujar 2 1 Thermo Fisher Scientific, Breda, NL 2 Thermo Fisher Scientific,
More informationThermo Scientific Pesticide Explorer Collection. Start-to-finish. workflows for pesticide analysis
Thermo Scientific Pesticide Explorer Collection Start-to-finish workflows for pesticide analysis Comprehensive Pesticide Analysis Solutions Pesticide Explorer Collection Selection table Lab Profile Routine
More informationSEAMLESS INTEGRATION OF MASS DETECTION INTO THE UV CHROMATOGRAPHIC WORKFLOW
SEAMLESS INTEGRATION OF MASS DETECTION INTO THE UV CHROMATOGRAPHIC WORKFLOW Paula Hong, John Van Antwerp, and Patricia McConville Waters Corporation, Milford, MA, USA Historically UV detection has been
More informationPowerful Scan Modes of QTRAP System Technology
Powerful Scan Modes of QTRAP System Technology Unique Hybrid Triple Quadrupole Linear Ion Trap Technology Provides Powerful Workflows to Answer Complex Questions with No Compromises While there are many
More informationINTRODUCTION OVERVIEW
COMPARISON OF CCS(N 2 ) MEASUREMENTS OBTAINED FROM TWO DIFFERENT T-WAVE ION S WITH DIRECT MEASUREMENTS USING A DRIFT TUBE ION Kevin Giles, Martin Palmer, Keith Richardson, Nick Tomczyk Waters MS Technologies
More informationAccelerate Unknown Detection in Emerging Drug Testing Using Thermo Scientific Compound Discoverer and mzcloud
Accelerate Unknown Detection in Emerging Drug Testing Using Thermo Scientific Compound Discoverer and mzcloud Ed Goucher ClinTox Marketing Manager Thermo Fisher Scientific v1 The world leader in serving
More informationQuantitative Analysis of Opioids Using a Triple-Quadrupole GC/MS/MS
PO-CON1408E Quantitative Analysis of Opioids Using a Pittcon 2014 1090-8P Laura Chambers, Richard Whitney, Ph.D., Nicole M. Lock, Zhuangzhi Max Wang, Ph.D., Clifford M. Taylor; Shimadzu Scientific Instruments,
More informationLC/Q-TOF Workflows for Comprehensive Micropollutant Analysis
LC/Q-TO Workflows for Comprehensive Micropollutant Analysis Targeted Quantification, Suspect Screening, and Unknown Compound Identification Application Note Environmental Authors Christoph Moschet and
More informationStephen McDonald, Mark D. Wrona, Jeff Goshawk Waters Corporation, Milford, MA, USA INTRODUCTION
Combined with a Deep Understanding of Complex Metabolic Routes to Increase Efficiency in the Metabolite Identification Search Stephen McDonald, Mark D. Wrona, Jeff Goshawk Waters Corporation, Milford,
More informationAgilent ESI and APCI sources: for polar to non-polar compounds
1 Agilent 6400 Series Triple Quadrupole Users Workshop 1 Agilent ESI and APCI sources: for polar to non-polar compounds Nebulizer Pressure Corona current Nebulizer Pressure Vaporizer Vcap Vcap Drying Gas
More informationAgilent 6400 Series Triple Quadrupole LC/MS/MS Users Session
Agilent 6400 Series Triple Quadrupole LC/MS/MS Users Session QQQ Method Development and Optimization MassHunter Quant: Method setup Peak detection optimization Quant troubleshooting David Presser Application
More information2016 iquan Series: Pesticide Quantitation on the Thermo Scientific TSQ Quantiva
2016 iquan Series: Pesticide Quantitation on the Thermo Scientific TSQ Quantiva Craig Dufresne and Kevin McHale, Content Creators The world leader in serving science The Whole Workflow Efficiency in sample
More informationBenefits of Equipping your Lab with a Time-of-Flight Mass Spectrometer
Benefits of Equipping your Lab with a Time-of-Flight Mass Spectrometer Purchasing a mass spectrometer (MS) is an important investment for a laboratory. When considering instrument platforms, selection
More information[ APPLICATION NOTEBOOK ] STRUCTURAL ELUCIDATION
[ APPLICATION NOTEBOOK ] STRUCTURAL ELUCIDATION 1 This notebook is an excerpt from the larger Waters Application Notebook on Metabolomics and Lipidomics #720005245EN TABLE OF CONTENTS 3 Introduction 4
More informationIdentifying Disinfection Byproducts in Treated Water
Identifying Disinfection Byproducts in Treated Water Jonathan D. Byer, LEC Corporation; Saint Joseph, Michigan USA Susan D. Richardson, University of South Carolina; Columbia, South Carolina USA 1. Introduction
More informationAnalytical Test Report 10
OLCC #022892C 9 SE Division St. Laboratory ID: 805024-02 Batch ID: AC Date Sampled: 05/07/8 Date Printed: 05//8 Report cannot be used for OLCC/OHA compliance. Date Sampled: 05/07/8 00:00 Date Accepted:
More informationTraditional Herbal Medicine Structural Elucidation using SYNAPT HDMS
Traditional Herbal Medicine Structural Elucidation using SYNAPT HDMS with Time-Aligned Parallel (TAP) Fragmentation Kate Yu, Jose Castro-Perez, and John Shockcor Waters Corporation, Milford, MA, U.S. INTRODUCTION
More informationAnalyte Targeting for NPS Identification in Seized Drugs and Toxicology
Analyte Targeting for NPS Identification in Seized Drugs and Toxicology Alex J. Krotulski, MS Research Scientist Center for Forensic Science Research & Education Background Explosion and expansion of NPS
More information[ instrument specifications ]
Designed for leading researchers working at the limits of conventional mass spectrometry capabilities who need to further characterize and define their samples the Waters SYNAPT High Definition MS (HDMS
More information