1 Minimizing matrix effects in multiresidue pesticide analysis using a new sensitivity-enhanced triple quadrupole instrument in combination with extensive sample dilution László Tölgyesi LC/MS scientist EFSC Demo Group International Symposium on Food Safety and Quality: Applications of Nuclear and Related Techniques IAEA Vienna /0/04
2 Pesticides screening regulation and residue situation EU regulation - Maximum residue levels regulated in commision regulation (EC) 96/005 appendix II IV regulates > maximum residue limits (matrix-pesticide combinations) - European and national monitoring programs are in place also regulated by (EC) 96/005 - notifications related to pesticide residues in tea have been entered in the Rapid Alert System for Food and Feed (RASFF) IAEA Vienna /0/04
3 Why do you want a 6495? Utmost sensitivity is required for the analysis of a large number of relevant compounds with a single injection dilution of samples for reduced matrix effects, better accuracy and improved robustness improved LOQs for pesticides in complex matrices highest precision Experimental setup Small validation with tomato, orange, black tea QuEChERS extraction Dilution of black tea samples with acetonitrile prior injection Quantitation with solvent calibration one calibration for all matrices? IAEA Vienna /0/04
4 x UHPLC/MS/MS Setup 90 Infinity UHPLC column: Zorbax RRHD Eclipse Plus C8 A: H O / 0.% HCOOH / 5mM NH 4 COOH B: MeOH / 0.% HCOOH / 5mM NH 4 COOH 6495 LC/MS system single run, fast polarity switching, dynamic MRM 4 Aminocarb Oxamyl Thiabendazole Acetamiprid Thiacloprid Tricyclazole Pirimicarb Carbofuran Pyracarbolid Prometon Methabenzthiazuron DEET Clomazone Furalaxyl Isoxaben Triazophos Metolachlor Beflubutamid Benalaxyl Pencycuron Triflumizole Prosulfocarb Picolinafen Pyriproxyfen Spiromesifen Carbosulfan Etofenprox Ivermectin Ba Fenazaquin Spiked and diluted tea extract (0. ng/ml) Counts vs. Acquisition Time (min) IAEA Vienna /0/04 4
5 Proven ifunnel Technology Agilent Jet Stream Hexabore Capillary Dual Ion Funnel Thermal confinement of ESI plume Efficient desolvation Creates an ion rich zone Six capillary bores Samples x6 times more ion rich gas from the source Removes the gas but captures the ions Removes neutral noise IAEA Vienna /0/04 5
6 6495 QQQ Technologies Continued Development Proven ifunnel Technology Agilent Jet Stream Hexabore Capillary Dual Ion Funnel Increased ion generation Enhanced ion sampling New Enhanced Q Ion Optics Improved ion transmission New Tapered Hexapole Collision Cell Effective ion collection and transmission New Detector with High Energy Conversion Dynode (up to 0 kv) Improved NEG ion detection with low noise IAEA Vienna /0/04 6
7 New Enhanced Q Ion Optics Improved transmission of ions and system robustness. Octopole. New prefilter New optimized MS prefilter geometry for improved precursor ion transmission Improved peak area response and peak area %RSD, more sensitive and precise New optical lens elements for reduced contamination and easier autotune More reliable and robust performance IAEA Vienna /0/04 7
8 New Curved and Tapered Hexapole Collision Cell Effective collection and transmission of ions Curved and Tapered Hexapole Assembly for efficient collection and transmission of product ions Consistent collision cell pressure for higher quality MS/MS spectra Designed for consistent collision energies across all QQQ platforms IAEA Vienna /0/04 8
9 New Detector with 0 kv High Energy Conversion Dynode More efficient detection of ions with low noise characteristics Gain in Signal with Higher HED Voltage: Anti-EHR/neu mab Peptides Improved ion detection efficiency with High Energy Dynode (HED) voltage up to 0 kv - Improved peak area response and peak area %RSD in positive & negative ion mode - Improved sensitivity and precision for a wide m/z range of product ions Low noise level at 0 kv - Improved signal to noise 60 0% increase in response at 0kV IAEA Vienna /0/04 9
10 6495 QQQ Technologies Continued Development Proven ifunnel Technology Agilent Jet Stream Hexabore Capillary Dual Ion Funnel Increased ion generation Enhanced ion sampling New Enhanced Q Ion Optics Improved ion transmission New Tapered Hexapole Collision Cell Effective ion collection and transmission New Detector with High Energy Conversion Dynode Improved NEG ion detection with low noise Quantitative Applications Enhanced peak area response Improved peak area %RSD More sensitive and precise Lower Limits of Detection (IDL)and Quantitation (LLOQ) More reliable and robust IAEA Vienna /0/04 0
11 Bentazon: Superb Precision & Sub-fg IDL in Black Tea Amount measured Replicates %RSD t(99%) IDL pg/ml,.0 fg (LLOQ) n = 7 injections pg/ml, 0.7 fg IDL = t x (%RSD/00) x Amount =.4 x (.4/00) x.0 fg = 0.7 fg Injection volume = µl x0 -ESI MRM Frag=80.0V CID@6.0 (9. -> x0 -ESI MRM Frag=80.0V CID@6.0 (9. -> 8 pg/ml * pg/ml pg/ml 6 6 x ESI MRM Frag=80.0V CID@6.0 (9. -> pg/ml * x ESI MRM Frag=80.0V CID@6.0 (9. -> pg/ml Inj# Peak Area S/N (Peak to peak) x0 8 -ESI MRM Frag=80.0V CID@6.0 (9. -> pg/ml. 70. x0 8 -ESI MRM Frag=80.0V CID@6.0 (9. -> pg/ml Counts vs. Acquisition Time (min) Counts vs. Acquisition Time (min) %RSD.4 Ave 6. Excellent peak area precision (%RSD) are observed at the lowest level in black tea matrix IAEA Vienna /0/04
12 Signal Improvements for High Relevance Pesticides 0ng/g in BlackTea_-0dil [Methomyl] x > 88. Area= > 06. Area= ng/g in BlackTea_-0dil [Methomyl] 0ng/g in BlackTea_-0dil [Methidathion] 0ng/g in BlackTea_-0dil [Methidathion] x > 88. Area=55 x > 45.0 Area=50 x > 45.0 Area= > 06. Area= > 85. Area= > 85. Area=56 Methomyl Area Gain.5x Methidathion Area Gain.7x 0ng/g in BlackTea_-0dil [Monocrotophos] x > 7.0 Area= > 9. Area=77 0ng/g in BlackTea_-0dil [Monocrotophos] x > 7.0 Area= > 9. Area=56 MonocrotophosArea Gain.9x 0ng/g in BlackTea_-0dil [Buprofezin] x > 0. Area= > 6. Area=958 0ng/g in BlackTea_-0dil [Buprofezin] x > 0. Area= > 6. Area= Buprofezine Area Gain 4.x ng/g in BlackTea_-0dil [Thiabendazol] x > 75. Area= >. Area= ng/g in BlackTea_-0dil [Thiabendazol] x > 75. Area= >. Area= ng/g in BlackTea_-0dil [Spiromesifen] x > 7.0 Area= > 55.0 Area= Area Gain.x Thiabendazole ng/g in BlackTea_-0dil [Spiromesifen] x > 7.0 Area= > 55.0 Area= Spiromesifen Area Gain.x Improved sensitivity (peak area gain of x) are observed on the new 6495 vs. the 6490 IAEA Vienna /0/04
13 Improved Precision & Lower LLOQs in Black Tea Comparison of Area %RSD for 50 Pesticides at MRL # of pesticides detected at MRL % of pesticides were easily detected with a %RSD < 0 with :00 dilution This means LLOQs < 0 pg/ml (ppt) %RSD < 0 meets SANCO guidelines Improved precision (%RSD) are observed, particularly at the lowest levels (LLOQs) The enhanced peak area response and improved precision (%RSD) means pesticides achieve lower LLOQs ( MRL level) using the new IAEA Vienna /0/04
14 Dilution allows More Efficient Ionization of Pesticides Alanycarb, 0 µg/kg in Black Tea No Dilution : 5 : 0 : 0 : 50 : 00 Oxamyl, 0 µg/kg in Black Tea No Dilution : 5 : 0 : 0 : 50 : 00 IAEA Vienna /0/04 4
15 Recovery (%) in Black Tea with Different Dilutions Pesticides No dilution (n = 5) Dilution :5 (n = 5) Dilution :0 (n = 5) Dilution :0 (n = 5) Dilution :50 (n = 5) Dilution :00 (n = 5) Acetamiprid 9.4 ± ± ± ± ± ±.4 Alanycarb 0.4 ±. 7.9 ±. 8.5 ± ± ± ± 0.8 Aldicarb 6.9 ± ± ± ± ± ± 4. Carbaryl 56.9 ± ± ± ± ± ± 9.6 Dimethoate.9 ± ± ± ± ± ± 7.5 Diuron 79.7 ± ± ± ± ± ±.5 Flufenoxuron 95.4 ± ± ±.8 9. ± ± ±.9 Monocrotophos 4.6 ± 0..9 ± 0..8 ± ± ± ± 5.7 Oxamyl 0.8 ± ± ± ±.0 9. ± ± 5. Thiamethoxam 40.0 ± ± ±.8 5. ± ± ±.0 Cells shaded in green shows %recovery of 70 0, which are in compliance with SANCO requirements. Pesticides show full recovery and no signal suppression with :00 dilution Neat solvent calibration curve can be used for pesticides quantitation with :00 dilution IAEA Vienna /0/04 5
16 Summary - The method benefits from the highly sensitive Agilent 6495 Triple Quadrupole LC/MS System. - It takes full advantage of the low delay volumes of the Agilent 90 Infinity LC System. - Enhanced sensitivity allowed for more flexibility in the degree of sample dilution. - Extensive dilution of sample extracts was applied to minimize matrix effects - With any dilution, a lower matrix amount is introduced into the LC/MS system IAEA Vienna /0/04 6
17 Thank you for your attention! IAEA Vienna /0/04 0
Routine Multiresidue Pesticide Analysis using the Agilent 6470 Triple Quadrupole Mass Spectrometer
Routine Multiresidue Pesticide Analysis using the Agilent 6470 Triple Quadrupole Mass Spectrometer Application Note Food safety Authors Mark Sartain and Anabel Fandino Agilent Technologies, Inc. Santa
More informationAgilent 6495 Triple Quadrupole LC/MS System EXPERIENCE A NEW LEVEL OF CONFIDENCE
Agilent 49 Triple Quadrupole LC/MS System EXPERIENCE A NEW LEVEL OF CONFIDENCE AGILENT 49 TRIPLE QUADRUPOLE LC/MS SYSTEM WORK SMARTER, DO MORE ifunnel new Q1 Optics new Ion Detector IMPROVED SENSITIVITY
More informationDetermination of pesticides in baby food by UHPLC/MS/MS using the Agilent 1290 Infinity LC system and the Agilent 6460 triple quadrupole LC/MS
Determination of pesticides in baby food by UHPLC/MS/MS using the Agilent 1290 Infinity LC system and the Agilent 6460 triple quadrupole LC/MS Application Note Food Authors Gerd Vanhoenacker, Frank David,
More informationMultiresidue Analysis of 100 Pesticides in Food Samples by LC/Triple Quadrupole Mass Spectrometry Application
Multiresidue Analysis of Pesticides in Food Samples by LC/Triple Quadrupole Mass Spectrometry Application Food Safety Authors Imma Ferrer and E. Michael Thurman Pesticide Residue Research Group University
More informationMulti-residue analysis of pesticides by GC-HRMS
An Executive Summary Multi-residue analysis of pesticides by GC-HRMS Dr. Hans Mol is senior scientist at RIKILT- Wageningen UR Introduction Regulatory authorities throughout the world set and enforce strict
More informationIdentification and Quantitation of Pesticides in Chamomile and Ginger Extracts Using an Agilent 6460 Triple Quadrupole LC/MS system with Triggered MRM
Identification and Quantitation of Pesticides in Chamomile and Ginger Extracts Using an Agilent 646 Triple Quadrupole LC/MS system with Triggered MRM Application Note Authors Thomas Glauner Agilent Technologies,
More informationRapid Pesticide Screening and Identification Using the High Resolution All Ions MS/MS Technique
Rapid Pesticide Screening and Identification Using the High Resolution All Ions MS/MS Technique Application Note Food Safety Authors Bernhard Wüst and Thomas Glauner Agilent Technologies GmbH Waldbronn
More informationScreening and Quantitation of 240 Pesticides in Difficult Food Matrixes Using the Agilent 6545 Q-TOF LC/MS System
Screening and Quantitation of 24 Pesticides in Difficult Food Matrixes Using the Agilent 6545 Q-TOF LC/MS System Application Note Authors Dan-Hui Dorothy Yang, Christian Klein, Crystal Cody, and Huy Bui
More informationTaking Full Advantage of UHPLC with Agilent 6460A Triple Quadrupole MS. Outline
Taking Full Advantage of UHPLC with Agilent 0A Triple Quadrupole MS Dr. Anabel Fandino R&D Application Scientist LC/MS Division Agilent Technologies Santa Clara, CA utline Ultra High Definition LC/MS using
More informationIntroducing the Agilent 7000A QQQ-MS for GC Sunil Kulkarni Product Specialist Agilent Technologies
Introducing the Agilent 7000A QQQ-MS for GC Sunil Kulkarni Product Specialist Agilent Technologies Page 1 Agilent GC/MS Portfolio Smallest footprint, single GC column 5975VL with 6850GC Industry leading
More informationAgilent ESI and APCI sources: for polar to non-polar compounds
1 Agilent 6400 Series Triple Quadrupole Users Workshop 1 Agilent ESI and APCI sources: for polar to non-polar compounds Nebulizer Pressure Corona current Nebulizer Pressure Vaporizer Vcap Vcap Drying Gas
More informationUtility of H-SRM to Reduce Matrix Interference in Food Residue Analysis of Pesticides by LC-MS/MS Using the TSQ Quantum Discovery
Application Note: 3 Utility of H-SRM to Reduce Matrix Interference in Food Residue Analysis of Pesticides by LC-MS/MS Using the TSQ Quantum Discovery Yoko Yamagishi, Thermo Fisher Scientific, C-2F 3-9
More informationThe Agilent 6495 Triple Quadrupole LC/MS: Peptide Quantitation Performance
The Agilent 495 Triple Quadrupole LC/MS: Peptide Quantitation Performance Technical Overview Introduction Sample complexity and the low concentration of certain biomarkers are the major challenges encountered
More informationAgilent 6460 Triple Quadrupole LC/MS System with an Agilent 1290 Infinity LC For Multi-Plant Growth Regulator Analysis in Grapes
Agilent 6460 Triple Quadrupole LC/MS System with an Agilent 1290 Infinity LC For Multi-Plant Growth Regulator Analysis in Grapes Application Note Food Safety Author Sunil Kulkarni Agilent Technologies
More informationAnalytical determination of testosterone in human serum using an Agilent Ultivo Triple Quadrupole LC/MS
Application Note Clinical Research Analytical determination of testosterone in human serum using an Agilent Ultivo Triple Quadrupole LC/MS Authors Yanan Yang 1, Victor Mandragon 2, and Peter Stone 1 1
More informationQTRAP and SelexION+- Improving the Sensitivity, Speed and Selectivity in Food, Clinical Research and Pharmaceutical Applications
QTRAP 6500+ and SelexION+- Improving the Sensitivity, Speed and Selectivity in Food, Clinical Research and Pharmaceutical Applications Jianru Stahl-Zeng. Ph D Darmstadt, Germany Agenda 6500 + LC/MS System
More informationHigher Confidence in Identification with QTRAP LC/MS/MS Systems when Screening and Quantifying Pesticides in Fruit and Vegetable Samples
Higher Confidence in Identification with QTRAP LC/MS/MS Systems when Screening and Quantifying Pesticides in Fruit and Vegetable Samples André Schreiber AB SCIEX, Concord, Ontario, Canada Figure 1. Ion
More informationFully automated QuEChERS clean-up and LC/MS-QQQ analysis of pesticides in fruits and vegetables.
Chromatography Technical Note No AS90 Fully automated QuEChERS clean-up and LC/MS-QQQ analysis of pesticides in fruits and vegetables. Paul H. Roberts, Anatune Ltd. Hardwick, Cambridgeshire, UK. Introduction
More informationAgilent 6400 Series Triple Quadrupole Users Workshop. MH QQQ Users workshop 2/21/2014 1
Agilent 6400 Series Triple Quadrupole Users Workshop 1 Agilent 6400 Series Triple Quadrupole Users Workshop QQQ Method Development and Optimization MassHunter Quantitation: Batch and Method setup QC s,
More informationApplication of a Triggered MRM Database and Library for the Quantitation and Identification of Pesticides in Food Extracts
Application of a Triggered MRM Database and Library for the Quantitation and Identification of Pesticides in Food Extracts Application Note Food Authors Thomas Glauner Agilent Technologies, Inc. Waldbronn,
More informationApplication Note. Author. Abstract. Food Testing & Agriculture. Edgar Naegele Agilent Technologies, Inc. Waldbronn, Germany
Analysis of Pesticides by Supercritical Fluid Chromatography/ Mass Spectrometry Optimizing the Agilent 126 Infi nity Analytical SFC System in Combination with the Agilent 646 Triple Quadrupole LC/MS Application
More informationThe Agilent 6545 Q-TOF LC/MS System THE ANSWERS YOU NEED: BETTER, FASTER, EASIER
The Agilent 6545 Q-TOF LC/MS System THE ANSWERS YOU NEED: BETTER, FASTER, EASIER THE AGILENT 6545 Q-TOF LC/MS SYSTEM FASTER ANSWERS BETTER MEASUREMENTS EASIER HIGH PERFORMANCE RESULTS The new 6545 Q-TOF
More informationApplication Note. Abstract. Authors. Food Safety and Environmental
Multi-Residue Pesticide Analysis with Dynamic Multiple Reaction Monitoring and Triple Quadrupole LC/MS/MS Fast and Effective Method Development Using an Application Kit and a Pesticides Compound Parameter
More informationRapid Screening and Confirmation of Melamine Residues in Milk and Its Products by Liquid Chromatography Tandem Mass Spectrometry
Rapid Screening and Confirmation of Melamine Residues in Milk and Its Products by Liquid Chromatography Tandem Mass Spectrometry Application Note Food Authors Jianqiu Mi, Zhengxiang Zhang, Zhixu Zhang,
More informationAgilent s LC/MS Portfolio and Applications Examples
Agilent s LC/MS Portfolio and Applications Examples Michael Scott LC/MS Product Specialist Agilent Technologies March 2013 For Research Use Only. Not for use in diagnostic procedures. Agilent 6000 Series
More informationUltra-fast screening of pesticides in foods and agricultural products with desorption corona beam ionization (DCBI) tandem mass spectrometry
PO-CON18E Ultra-fast screening of pesticides in foods and agricultural products with desorption corona beam ionization (DCBI) ASMS 21 TP 3 Jing Dong, Satoshi Yamaki, Yuki Hashi, Naoki Hamada Shimadzu China,
More informationDetermination of Pesticide Residues in Oats by Automated. QuEChERS and LC/QQQ. Application Note. Abstract. Introduction
Determination of Pesticide Residues in Oats by Automated QuEChERS and LC/QQQ Application Note Abstract The QuEChERS (Quick-Easy-Cheap-Effective-Rugged-Safe) sample extraction method was developed for the
More informationLC/MS/MS qua ntitation of β-estradiol 17-acetate using an Agilent 6460 Triple Quadrupole LC/MS working in ESI negative ion mode
LC/MS/MS qua ntitation of β-estradiol 17-acetate using an Agilent 6460 Triple Quadrupole LC/MS working in ESI negative ion mode Application Note Authors Siji Joseph Agilent Technologies India Pvt. Ltd.
More informationSensitive Femtogram Determination of Aflatoxins B 1 , B 2 , G 1. and G 2. in Food Matrices using Triple Quadrupole LC/MS. Authors.
Sensitive Femtogram Determination of Aflatoxins B 1, B 2, G 1 and G 2 in Food Matrices using Triple Quadrupole LC/MS Application Note Food Safety Authors Yang Chen and Jack Cappozzo National Center for
More informationAnalysis of Pesticides in Citrus Oil Using a Shimadzu GCMS-TQ8030. No. GCMS No. SSI-GCMS-1404
Gas Chromatograph Mass Spectrometer No. GCMS-1404 Analysis of Pesticides in Citrus Oil Using a Shimadzu GCMS-TQ8030 Introduction Contamination of consumer products with pesticides is a growing concern
More informationDETERMINATION OF PESTICIDES IN FOOD USING UPLC WITH POLARITY SWITCHING TANDEM QUADRUPOLE LC/MS/MS
DETERMINATION OF PESTICIDES IN FOOD USING UPLC WITH POLARITY SWITCHING TANDEM QUADRUPOLE LC/MS/MS Peter Hancock 1, Cristiana C. Leandro 2,3, Brendan J. Keely 2 and Richard J. Fussell 3 1 Waters Corporation,
More informationMulti-residue analysis of pesticides in crude food extracts using a simple extraction technique and LC/MS/MS
PO-CON1529E Multi-residue analysis of pesticides in crude food extracts using a simple extraction technique and LC/MS/MS ASMS 215 WP 77 Miho Kawashima 1, Yuka Fujito 2, Yayoi Ichiki 3, Miho Sakai 4, Takashi
More informationYun W. Alelyunas, Mark D. Wrona, Russell J. Mortishire-Smith, Nick Tomczyk, and Paul D. Rainville Waters Corporation, Milford, MA, USA INTRODUCTION
Quantitation by High Resolution Mass Spectrometry: Using Target Enhancement and Tof-MRM to Achieve Femtogram-level On-column Sensitivity for Quantitation of Drugs in Human Plasma Yun W. Alelyunas, Mark
More informationSensitive and Repeatable Analysis of Pesticides in QuEChERS Extracts with APGC-MS/MS
Sensitive and Repeatable Analysis of Pesticides in QuEChERS Extracts with APGC-MS/MS Dominic Roberts, 1 Sara Stead, 1 and Jennifer A. Burgess 2 1 Waters Corporation, Manchester, UK 2 Waters Corporation,
More informationUsing UHPLC-Triple Quadrupole MS/MS to Detect the Presence of Bark Extract and Yohimbine Adulteration in Dietary Supplements and Botanicals
Using UHPLC-Triple Quadrupole MS/MS to Detect the Presence of Bark Extract and Adulteration in Dietary Supplements and Botanicals Application Note Food Testing & Agriculture Authors James Neal-Kababick
More informationNew Dynamic MRM Mode Improves Data Quality and Triple Quad Quantification in Complex Analyses
New Dynamic MRM Mode Improves Data Quality and Triple Quad Quantification in Complex Analyses Technical Overview Authors Abstract Peter Stone, Thomas Glauner, Frank Kuhlmann, Tim Schlabach and Ken Miller
More informationDetermination of Beta-Blockers in Urine Using Supercritical Fluid Chromatography and Mass Spectrometry
Determination of Beta-Blockers in Urine Using Supercritical Fluid Chromatography and Mass Spectrometry Application Note Doping Control Authors Prof. Maria Kristina Parr Freie Universität Berlin Institute
More informationMacrolides in Honey Using Agilent Bond Elut Plexa SPE, Poroshell 120, and LC/MS/MS
Macrolides in Honey Using Agilent Bond Elut Plexa SPE, Poroshell 120, and LC/MS/MS Application Note Food Testing and Agriculture Author Chen-Hao (Andy) Zhai and Rong-jie Fu Agilent Technologies (Shanghai)
More informationApplying MRM Spectrum Mode and Library Searching for Enhanced Reporting Confidence in Routine Pesticide Residue Analysis
PO-CON1768E Applying MRM Spectrum Mode and Library Searching for Enhanced Reporting Confidence in Routine Pesticide ASMS 2017 TP-194 David Baker 1, Christopher Titman 1, Neil Loftus 1, Jonathan Horner
More informationValidation Report 18
EURL for Cereals and Feeding stuff National Food Institute Technical University of Denmark Validation Report 18 Determination of pesticide residues in maize for livestock feed by GC-MS/MS and LC-MS/MS
More informationLC/Q-TOF Workflows for Comprehensive Micropollutant Analysis
LC/Q-TO Workflows for Comprehensive Micropollutant Analysis Targeted Quantification, Suspect Screening, and Unknown Compound Identification Application Note Environmental Authors Christoph Moschet and
More informationTheory and Practical Consequences.
Theory and Practical Consequences. Number of hits depending on reachable mass accuracy 250 hits @ ±10 ppm 137 hits @ ±5 ppm 78 hits @ ±3 ppm 29 hits @ ±1 ppm 3 hits @ ±0.1 ppm 1 hit @ ± 0.05 ppm Intens.
More informationComprehensive Pesticide Analysis in Juice Using a Combination of GC/MS and LC/MS Methods
Comprehensive Pesticide Analysis in Juice Using a Combination of GC/MS and LC/MS Methods Application Note Food Safety Authors Fadwa Al-Taher, Rima Juskelis, Yang Chen, Jack Cappozzo Institute for Food
More informationTranslational Biomarker Core
Translational Biomarker Core Instrumentation Thermo Scientific TSQ Quantum Triple Quadrupole Mass Spectrometers. There are two TSQ Quantum Ultra AM instruments available in the TBC. The TSQ Quantum Ultra
More informationHighly Sensitive and Rugged GC/MS/MS Tool
Highly Sensitive and Rugged GC/MS/MS Tool For Pesticide Multiresidue Analysis in Food Samples Agilent 7 Series Triple Quadrupole GC/MS. The world s first MS/MS designed specifically for GC Analysis Introduction
More informationFood & Environmental. Overview. Introduction. Method Details. André Schreiber and Yun Yun Zou SCIEX, Concord, Ontario, Canada
Food & Environmental Comprehensive Quantitation and Identification of Pesticides in Food Samples using LC-MS/MS with Scheduled MRM, Fast Polarity Switching, and MS/MS Library Searching André Schreiber
More informationSeparation of Enantiomers of Amphetamine-Related Drugs and Their Structural Isomers
Application Note Forensic and Toxicology - Criminalistics Separation of Enantiomers of Amphetamine-Related Drugs and Their Structural Isomers Using the Agilent 126 Infinity II SFC and Detection by Coupled
More informationAlmería 23 rd -25 th October th Joint Workshop of the European Union Reference Laboratories for Residues of Pesticides
General European Commission Proficiency Test Scheme EURL-FV Scientific Group Samples and Protocol INFORMATION EUPT Web Page Data Analysis Reports 1 2 3 4 5 ACTIVITY DATE Publishing the Calendar and Matrix
More informationAnalysis of Low-Calorie Sweeteners by Liquid Chromatography-Tandem Mass Spectrometry
Analysis of Low-Calorie Sweeteners by Liquid Chromatography-Tandem Mass Spectrometry Application Note Food safety Authors Ismael Flores and Carlos Sepulveda Agrolab México Km 7 Carretera Pachuca-Actopan
More informationDetermination of Pesticide Multiresidues in Apple, Pear and Grape using modified QuEChERS and analysis by LC-QTOF MS
Determination of Pesticide Multiresidues in Apple, Pear and Grape using modified QuEChERS and analysis by LC-QTOF MS Application Note Authors Renato Zanella, Juliana S. Munaretto, and Manoel L. Martins
More informationIntroducing the Agilent G6410A Triple Quadrupole Mass Spectrometer
Introducing the Agilent G6410A Triple Quadrupole Mass Spectrometer Michael Zumwalt Quad Mass Filter (Q1) Quad Mass Filter (Q3) Ion source Collision Cell Overview of QQQ Hardware QQQ Mechanical Layout Common
More informationAnalysis of Illegal Dyes in Food Matrices using Automated Online Sample Preparation with LC/MS
Application Note: 56 Analysis of Illegal Dyes in Food Matrices using Automated Online Sample Preparation with LC/MS Yang Shi, Catherine Lafontaine, Matthew Berube, John Fink, François Espourteille Thermo
More informationSimultaneous Determination of Paraquat and Diquat in Environmental Water Samples by HPLC-MS/MS
Simultaneous Determination of Paraquat and Diquat in Environmental Water Samples by HPLC-MS/MS Richard Jack, Xiaodong Liu, Leo Wang, and Chris Pohl OT70806_E 08/13S 1 The world leader in serving science
More informationOverview. Introduction
Comprehensive Quantitation and Identification of Pesticides in Food Samples Using the SCIEX UltraLC 100 and the SCIEX QTRAP 4500 System André Schreiber SCIEX, Concord, Ontario, Canada Overview Liquid Chromatography
More informationApplication Note LCMS-110 Development of a Targeted Quantitative LC-MS/MS Method for 431 Positive and Negative Ion Pesticides in a Single Analysis
Application Note LCMS-110 Development of a Targeted Quantitative LC-MS/MS Method for 431 Positive and Negative Ion Pesticides in a Single Analysis Abstract A rapid, targeted quantitative UHPLC-triple quadrupole
More informationLC/MS/MS of Fungicides and Metabolites in Orange Juice with Agilent Bond Elut Plexa and Poroshell 120
LC/MS/MS of Fungicides and Metabolites in Orange Juice with Agilent Bond Elut Plexa and Poroshell 10 Application Note Food Testing & Agriculture Author Irina Dioumaeva Agilent Technologies, Inc. Abstract
More informationAgilent Technologies LCMS Portfolio
Agilent Technologies LCMS Portfolio Hardware and Software Solutions for the Most Challenging Applications Jean-Francois Roy MS Product Specialist Agilent Technologies 1 Raising the Standard in UHPLC Highest
More informationScreening Method for 30 Pesticides in Green Tea Extract Using Automated Online Sample Preparation with LC-MS/MS
Application Note: 514 Screening Method for 3 Pesticides in Green Tea Extract Using Automated Online Sample Preparation with LC-MS/MS Yang Shi, Catherine Lafontaine, Thermo Fisher Scientific, Franklin,
More informationMaximizing Triple Quadrupole Mass Spectrometry Productivity with the Agilent StreamSelect LC/MS System
Maximizing Triple Quadrupole Mass Spectrometry Productivity with the Agilent StreamSelect LC/MS System Application Note Authors Kevin McCann, Sameer Nene, Doug McIntyre, Edmond Neo, Dennis Nagtalon, and
More informationAdvanced Data Acquisition and Data Processing Workflows to Identify, Quantify and Confirm Pesticide Residues
Advanced Data Acquisition and Data Processing Workflows to Identify, Quantify and Confirm Pesticide Residues André Schreiber 1 and Lauryn Bailey 2 1 AB SCIEX Concord, Ontario (Canada); 2 AB SCIEX Framingham,
More informationLC/MS/MS of Fungicides and Metabolites in Apple Juice with Agilent Bond Elut Plexa and Poroshell 120
LC/MS/MS of Fungicides and Metabolites in Apple Juice with Agilent Bond Elut Plexa and Poroshell 120 Application Note Food Testing & Agriculture Author Irina Dioumaeva Agilent Technologies, Inc. Abstract
More informationIMPROVING PESTICIDE RESIDUE DETECTION PROTOCOL FOR FRUIT
IMPROVING PESTICIDE RESIDUE DETECTION PROTOCOL FOR FRUIT Su Myeong Hong National Academy of Agricultural Science, Rural Development Administration (RDA), Wanju, Korea e-mail: wideyun@korea.kr ABSTRACT
More informationOverview. Introduction. Method Details. André Schreiber and Yun Yun Zou AB SCIEX, Concord, Ontario, Canada
Comprehensive Quantitation and Identification of Pesticides in Food Samples using LC-MS/MS with Scheduled MRM, Fast Polarity Switching, and MS/MS Library Searching André Schreiber and Yun Yun Zou AB SCIEX,
More informationTyler Trent, Applications Sales Specialist, Teledyne Tekmar P a g e 1
Application Note AutoMate-Q40 Automated QuEChERS Extraction for Pesticide Residues in Botanicals Tyler Trent, Applications Sales Specialist, Teledyne Tekmar P a g e 1 Abstract QuEChERS is a Quick-Easy-Cheap-
More informationValidation Report Determination of isoprothiolane residues in rice by GC-MS/MS (QuEChERS method)
NRL for Cereals DTU National Food Institute Validation Report Determination of isoprothiolane residues in rice by GC-MS/MS (QuEChERS method) Mette Erecius Poulsen & Hanne Bjerre Christensen 16 July 21
More informationAnaylsis of Pesticide Residues in Rice Using Agilent Bond Elut QuEChERS AOAC Kit by LC-MS/MS Detection
Anaylsis of Pesticide Residues in Rice Using Agilent Bond Elut QuEChERS AOAC Kit by LC-MS/MS Detection Application Note Food Safety Author Andy Zhai Agilent technologies Co., Ltd. 412 Yinglun Road Shanghai,
More informationLC-MS/MS multiresidue method used for pesticides analysis in fruits and vegetables
LC-MS/MS multiresidue method used for pesticides analysis in fruits and vegetables 1st International Symposium on Recent Advances in Food Analysis 5-7 ovember 2003, Prague Didier RTELLI, Patrick EDDER,
More informationLC/MS/MS Analysis of Pesticide Residues in Apples Using Agilent Chem Elut Cartridges
LC/MS/MS Analysis of Pesticide Residues in Apples Using Agilent Chem Elut Cartridges Application ote Food Testing & Agriculture Author Andy Zhai Agilent Technologies Shanghai Co. Ltd. Abstract This application
More information2010 Waters Corporation. Xevo TQ-S for Bioanalysis
Xevo TQ-S for Bioanalysis Key innovations High Performance Stepwave RADAR Scan Wave Versatility Ion Sources Simplicity of Operation Engineered Simplicity The Xevo TQ family Built on the same foundations
More informationValidation Data for the Analysis of 1-Napthylacetic acid and 1-Naphtylacetamide in tomato and zucchini Using Mini-Luke, Ethyl Acetate and QuEChERS methods Followed by LC-QqQ-MS/MS UNIVERSITY OF ALMERIA
More informationPlasma Metanephrines and 3-Methoxytyramine by LC/MS/MS Using Agilent SimpliQ WCX SPE, 1290 Infi nity LC, and 6460 Triple Quadrupole LC/MS
Plasma Metanephrines and 3-Methoxytyramine by LC/MS/MS Using Agilent SimpliQ WCX SPE, 129 Infi nity LC, and 646 Triple Quadrupole LC/MS Application Note Clinical Research Authors Linda Côté and Christophe
More informationThe new Water Screening PCDL
The new Water Screening PCDL Content and integration in suspect and non-target screening Dr. Thomas Glauner Senior LC/MS Applications Scientist EMEA Market Development Team 1 Accurate mass screening and
More informationQuadrupole Time-of-Flight Liquid Chromatograph Mass Spectrometer LCMS-9030 C146-E365
Quadrupole Time-of-Flight Liquid Chromatograph Mass Spectrometer LCMS-9030 C146-E365 Effortless Performance The LCMS-9030 quadrupole time-of-flight (Q-TOF) mass spectrometer integrates the world s fastest
More informationAnalysis of pesticide residues using various GC/MS systems. Radim Štěpán Czech Agriculture and Food Inspection Authority Prague, Czech Republic
Analysis of pesticide residues using various GC/MS systems Radim Štěpán Czech Agriculture and Food Inspection Authority Prague, Czech Republic OUTLINE Czech Agriculture and Food Inspection Authority (CAFIA)
More informationThe Use of the ACQUITY QDa Detector for a Selective, Sensitive, and Robust Quantitative Method for a Potential Genotoxic Impurity
The Use of the ACQUITY QDa Detector for a Selective, Sensitive, and Robust Quantitative Method for a Potential Genotoxic Impurity Janet Hammond Waters Corporation, Wilmslow, UK APPLICATION BENEFITS High
More informationAnalysis of Stachydrine in Leonurus japonicus Using an Agilent ZORBAX RRHD HILIC Plus Column with LC/ELSD and LC/MS/MS
Analysis of Stachydrine in Leonurus japonicus Using an Agilent ZORBAX RRHD HILIC Plus Column with LC/ELSD and LC/MS/MS Application Note Traditional Chinese Medicine Author Rongjie Fu Agilent Technologies
More informationGuide to Peptide Quantitation. Agilent clinical research
Guide to Peptide Quantitation Agilent clinical research Peptide Quantitation for the Clinical Research Laboratory Peptide quantitation is rapidly growing in clinical research as scientists are translating
More informationCharles Yang, Dipankar Ghosh, Jonathan Beck Thermo Fisher Scientific, San Jose, CA, USA
Utilization of High Resolution LC-MS for Screening and Quantitative Analysis of Pesticides in Food Matrix using a Q Exactive Benchtop Orbitrap Platform Charles Yang, Dipankar Ghosh, Jonathan Beck Thermo
More informationAgilent 6400 Series Triple Quadrupole LC/MS/MS Users Session
Agilent 6400 Series Triple Quadrupole LC/MS/MS Users Session QQQ Method Development and Optimization MassHunter Quant: Method setup Peak detection optimization Quant troubleshooting David Presser Application
More informationHigh Sensitivity HPLC Analysis of Perchlorate in Tap Water Using an Agilent 6460 Triple Quadrupole LC/MS System
High Sensitivity HPLC Analysis of Perchlorate in Tap Water Using an Agilent 66 Triple Quadrupole LC/MS System Application Note Environmental Authors Don Noot, Matthew Noestheden, and Ralph Hindle Vogon
More informationExtraction of Aflatoxins and Ochratoxin from Dried Chili Using ISOLUTE. Myco Prior to LC-MS/MS Analysis
Application Note AN785 Extraction of Aflatoxins and chratoxin From Dried Chili Using ISLUTE Myco prior to LC-MS/MS Analysis Page Extraction of Aflatoxins and chratoxin from Dried Chili Using ISLUTE Myco
More informationArticle. Pesticide Residues Method Validation by UPLC-MS/MS for Accreditation Purposes
http:dx.doi.org10.59350103-5053.20160012 Article J. Braz. Chem. Soc., Vol. 27, No. 7, 1165-1176, 2016. Printed in Brazil - 2016 Sociedade Brasileira de Química 0103-5053 $6.00+0.00 Pesticide Residues Method
More informationValidation Report 8 Determination of pesticide residues in rice and wheat by GC-MS/MS and LC-MS/MS (QuEChERS method) Appendix 2
EURL for Cereals and Feeding stuff National Food Institute Technical University of Denmark Validation Report 8 Determination of pesticide residues in rice and wheat by GC-MS/MS and LC-MS/MS (QuEChERS method)
More informationAnalytical considerations on the use of a fruit-specific and representative matrix in pesticide residue analysis by LC-ESI-MS/MS
Cent. Eur. J. Chem. 11(7) 2013 1112-1131 DOI: 10.2478/s11532-013-0247-y Central European Journal of Chemistry Analytical considerations on the use of a fruit-specific and representative matrix in pesticide
More informationAccurate Mass Analysis of Hydraulic Fracturing Waters: Identification of Polyethylene Glycol Surfactants by LC/Q-TOF-MS
Accurate Mass Analysis of Hydraulic Fracturing Waters: Identification of Polyethylene Glycol Surfactants by LC/Q-TOF-MS Application Note Authors E. Michael Thurman and Imma Ferrer Center for Environmental
More informationPesticides in Cannabis
LCMS-8040 Application Pesticides in Cannabis Jeff Dahl, 1 Julie Kowalski, 2 Jason Zitzer, 3 and Gordon Fagras 3 1 Shimadzu Scientific Instruments; Columbia, Maryland 2 Restek Corporation; Bellefonte, Pennsylvania
More informationA High Sensitivity Dual Solid Phase Extraction LC-MS/MS Assay for the Determination of the Therapeutic Peptide Desmopressin in Human Plasma
White Paper A High Sensitivity Dual Solid Phase Extraction LC-MS/MS Assay for the Determination of the Therapeutic Peptide Desmopressin in Human Plasma Lars Neudert, MSc, Senior Scientist Method Development
More informationdynamic MRM for pesticide analysis
The power of fast separation and dynamic MRM for pesticide analysis based on 1290/6460QQQ Dr. Volker Gnau Produkt Spezialist LCMS Page 1 3.) Quantitative analysis of pesticides (smrm) Chromatographic hi
More informationImproved Extraction of THC and its Metabolites from Oral Fluid Using Oasis PRiME HLB Solid Phase Extraction (SPE) and a UPLC CORTECS C 18
Using Oasis PRiME HLB Solid Phase Extraction (SPE) and a UPLC CORTECS C 18 Column Xin Zhang, Jonathan P. Danaceau, and Erin E. Chambers Waters Corporation, Milford, MA, USA APPLICATION BENEFITS Semi-validated
More informationQuantitative and Qualitative Confirmation of Pesticides in Beet Extract Using a Hybrid Quadrupole-Orbitrap Mass Spectrometer
Quantitative and Qualitative Confirmation of Pesticides in Beet Extract Using a Hybrid Quadrupole-Orbitrap Mass Spectrometer Charles Yang and Dipankar Ghosh, Thermo Fisher Scientific, San Jose, CA Olaf
More informationRapid method development to study plasma stability of diverse pharmaceutical compounds using Rapid Resolution LC and triple quadrupole MS
Rapid method development to study plasma stability of diverse pharmaceutical compounds using Rapid Resolution LC and triple quadrupole MS Application Note Drug Discovery Authors Srividya Kailasam Agilent
More informationAccurate Mass Analysis of Hydraulic Fracturing Waters
Application Note Environmental Accurate Mass Analysis of Hydraulic Fracturing Waters Using the Kendrick mass defect with the Agilent LC/Q-TOF MS Authors E. Michael Thurman and Imma Ferrer Department of
More informationAnalysis of Pesticides in Baby Foods Using a Triple-Quadrupole GC/MS/MS
PO-CONE Analysis of Pesticides in Baby Foods Using a Pittcon 01 -P Laura Chambers, Richard Whitney, Ph.D., Nicole M. Lock, Zhuangzhi Max Wang, Ph.D., Clifford M. Taylor; Shimadzu Scientific Instruments,
More informationAgilent s New 8800 ICP-QQQ. Transforming ICP-MS Technology
Agilent s New 8800 ICP-QQQ Transforming ICP-MS Technology 1 8800 ICP-QQQ Key Product Hardware High matrix introduction (HMI) technology Dual conical Extraction and Omega lens focuses ions across the mass
More informationUsing TOF for Screening and Quantitation of Sudan Red Colorants in Food Application
Using TOF for Screening and Quantitation of Sudan Red Colorants in Food Application Food Authors Yanyan Fang Agilent Technologies, Inc. 412 Ying Lun Road Pu Dong, Shanghai 200131 China Michael Zumwalt
More informationOF ANALYSIS FOR DETERMINATION OF PESTICIDES RESIDUES IN FOOD (CX/PR 15/47/10) European Union Competence European Union Vote
1 April 2015 European Union s CODEX COMMITTEE ON PESTICIDE RESIDUES 47 th Session Beijing, China, 13 18 April 2015 AGENDA ITEM 8 PROPOSED DRAFT GUIDELINES ON PERFORMANCE CRITERIA SPECIFIC FOR METHODS OF
More informationValidation of analytical methods. Adrian Covaci Toxicological Center, University of Antwerp
Validation of analytical methods Adrian Covaci Toxicological Center, University of Antwerp Why validate? The objective of validating an analytical method is to demonstrate its suitability for its intended
More informationOverview. Introduction. André Schreiber AB SCIEX Concord, Ontario (Canada)
Quantitation and Identification of Pharmaceuticals and Personal Care Products (PPCP) in Environmental Samples using Advanced TripleTOF MS/MS Technology André Schreiber AB SCIEX Concord, Ontario (Canada)
More informationDetermination of challenging elements in ultrapure semiconductor grade sulfuric acid by Triple Quadrupole ICP-MS
Determination of challenging elements in ultrapure semiconductor grade sulfuric acid by Triple Quadrupole ICP-MS Application note Semiconductor Authors Junichi Takahashi Agilent Technologies, Japan Introduction
More informationQuantitative Screening of 46 Illicit Drugs in Urine using Exactive Ultrahigh Resolution and Accurate Mass system
Quantitative Screening of 46 Illicit Drugs in Urine using Exactive Ultrahigh Resolution and Accurate Mass system Kevin Mchale Thermo Fisher Scientific, San Jose CA Presentation Overview Anabolic androgenic
More information