Triumphs and Challenges of High-Resolution Mass Spectrometry in Comprehensive Residue Screens

Size: px
Start display at page:

Download "Triumphs and Challenges of High-Resolution Mass Spectrometry in Comprehensive Residue Screens"

Transcription

1 Triumphs and Challenges of High-Resolution Mass Spectrometry in Comprehensive Residue Screens Florida Department of Agriculture Mark Crosswhite, Ph.D.

2 outline ur Goal identify and quantify quickly and reliably UHPLC v HPLC easy and cost effective improvement ur Two Platforms rbitrap and Triple Quad advantages of high resolution MS on the Exactive high resolution and high mass accuracy allows for post acquisition data mining limitations of high resolution MS on the Exactive cannot separate compounds with same exact masses no mass filtering fragments can be produced from any ions in the cell Resolution elucidate fragment formulas and structures use trusted triple quad fragments even though their identities are often unknown Exactive Plus vs. ABSciex real samples detection quantitation false positive realized Current and Future Strategies

3 outline ur Goal identify and quantify quickly and reliably UHPLC v HPLC easy and cost effective improvement ur Two Platforms rbitrap and Triple Quad advantages of high resolution MS on the Exactive high resolution and high mass accuracy allows for post acquisition data mining limitations of high resolution MS on the Exactive cannot separate compounds with same exact masses no mass filtering fragments can be produced from any ions in the cell Resolution elucidate fragment formulas and structures use trusted triple quad fragments even though their identities are often unknown Exactive Plus vs. ABSciex real samples detection quantitation false positive realized Current and Future Strategies

4 UHPLC Capacities of orthogonal analyses are multiplicative, not additive. Especially helpful with duty cycle issues in MRM MS (triple quad) and high resolution MS where there may not be MS/MS capabilities. propazine vs sebuthylazine m = Dimethomorph (E and Z) Acquity UPLC BEH C18 Cl Cl 1.7 µm 2.1 x 150 mm Flow rate.200 ml/min UHPLC HPLC UHPLC Time (min) Time (min) Time (min)

5 outline ur Goal identify and quantify quickly and reliably UHPLC v HPLC easy and cost effective improvement ur Two Platforms rbitrap and Triple Quad advantages of high resolution MS on the Exactive high resolution and high mass accuracy allows for post acquisition data mining limitations of high resolution MS on the Exactive cannot separate compounds with same exact masses no mass filtering fragments can be produced from any ions in the cell Resolution elucidate fragment formulas and structures use trusted triple quad fragments even though their identities are often unknown Exactive Plus vs. ABSciex real samples detection quantitation false positive realized Current and Future Strategies

6 representation of quadrupole in ms/ms mode Q1 Q2* Q3 mass filters fragments mass measures ion optics representation of rbitrap C-trap HCD cell* Sees what it looks for (MRM) ω=(qk/m) (1/2) orbitrap rbitrap sees everything all the time (full scan) Allows postacquisition data mining * fragments generated by colliding analyte with neutral gas

7 outline ur Goal identify and quantify quickly and reliably UHPLC v HPLC easy and cost effective improvement ur Two Platforms rbitrap and Triple Quad Advantages of High Resolution MS on the Exactive high resolution and high mass accuracy allows for post acquisition data mining limitations of high resolution MS on the Exactive cannot separate compounds with same exact masses no mass filtering fragments can be produced from any ions in the cell Resolution elucidate fragment formulas and structures use trusted triple quad fragments even though their identities are often unknown Exactive Plus vs. ABSciex real samples detection quantitation false positive realized Current and Future Strategies

8 what high resolution MS will do Phosmet [M + H + ] + = RT = min required resolution = m/(δm) Azinphos methyl [M + H + ] + = RT = min S S P S S P Triazophos [M + H + ] + = RT = min required resolution = Hexaconazole [M + H + ] + = RT = min Cl S P H Cl

9 resolving power simazine ( ) carbaryl ( ) RP required = thiabendazole ( ) resolvable with new rbitrap RP required = 4698 carbaryl ( ) m/z m/z

10 m/z m/z simulation v observed of a 1:10 mixture triazophos [M + H + ] + = hexaconazole [M + H + ] + = simulation resolution observed , , ,

11 outline ur Goal identify and quantify quickly and reliably UHPLC v HPLC easy and cost effective improvement ur Two Platforms rbitrap and Triple Quad advantages of high resolution MS on the Exactive rbitrap high resolution and high mass accuracy allows for post acquisition data mining limitations of high resolution MS on the Exactive cannot separate compounds with same exact masses no mass filtering fragments can be produced from any ions in the cell Resolution elucidate fragment formulas and structures use trusted triple quad fragments even though their identities are often unknown Exactive Plus vs. ABSciex real samples detection quantitation false positive realized Current and Future Strategies

12 what high resolution MS alone will not do Secbumeton [M + H + ] + = RT 8.23 min Prometon [M + H + ] + = RT 8.21 min Terbumeton [M + H + ] + = RT 8.32 min Prometryn [M + H + ] + = RT min S Terbutryn [M + H + ] + = RT min S

13 outline ur Goal identify and quantify quickly and reliably UHPLC v HPLC easy and cost effective improvement ur Two Platforms rbitrap and Triple Quad advantages of high resolution MS on the Exactive rbitrap high resolution and high mass accuracy allows for post acquisition data mining limitations of high resolution MS on the Exactive cannot separate compounds with same exact masses no mass filtering fragments can be produced from any ions in the cell Resolution elucidate fragment formulas and structures use trusted triple quad fragments even though their identities are often unknown Exactive Plus vs. ABSciex real samples detection quantitation false positive realized Current and Future Strategies

14 Extracted Ion Chromatogram (upper) Mass Spectra (lower) 8.21 PRMET STADARD Θ * Time (min) V Collision Energy 15 V Collision Energy Θ V Collision Energy * m/z

15 Extracted Ion Chromatogram (upper) Mass Spectra (lower) 8.32 TERBUMET STADARD Θ * Time (min) V Collision Energy 15 V Collision Energy Θ V Collision Energy * m/z

16 trusted triple quad fragments real detect.040 ug/g ABSciex 5500 azoxystrobin frag intensity (arb) azoxystrobin frag ug/g 0 V collision energy 15 V collision energy 45 V collision energy Exactive Plus Time extracted ion chromatogram azoxystrobin + H + extracted ion chromatogram mass = extracted ion chromatogram mass =

17 outline ur Goal identify and quantify quickly and reliably UHPLC v HPLC easy and cost effective improvement ur Two Platforms rbitrap and Triple Quad advantages of high resolution MS on the Exactive rbitrap high resolution and high mass accuracy allows for post acquisition data mining limitations of high resolution MS on the Exactive cannot separate compounds with same exact masses no mass filtering fragments can be produced from any ions in the cell Resolution elucidate fragment formulas and structures use trusted triple quad fragments even though their identities are often unknown Exactive Plus vs. ABSciex real samples detection quantitation false positive realized Current and Future Strategies

18 B 3688 compound matrix ABSciex 5500 quantitation (μg/g) Exactive plus quantitation (μg/g) percent difference exact mass (H+ adduct, Da) measured mass (Da) mass error (ppm) azoxystrobin eggplant pyraclostrobin blueberry dimethoate blueberry thiabendazole pear pyrimethanil strawberry flonicamid strawberry fluopicolide onion azoxystrobin onion thiabendazole apple imazalil banana

19 B 3704 compound matrix ABSciex 5500 quantitation (μg/g) Exactive plus quantitation (μg/g) percent difference exact mass (H+ adduct, Da) measured mass (Da) mass error (ppm) methamidophos collards * acephate collards dinotefuran collards thiabendazole papaya chlorantraniliprole collards chlorantraniliprole peas azoxystrobin papaya boscalid blackberries boscalid papaya * possible suppression in source or interference in mass measurement

20 B 3706 compound matrix ABSciex Exactive 5500 plus quantitation quantitation (μg/g) (μg/g) percent difference exact mass (H+ adduct, Da) measured mass (Da) mass error (ppm) methamidophos acephate bell peppers bell peppers * carbendazim okra azoxystrobin bell peppers azoxystrobin bell peppers boscalid tomato methoxyfenozide bell peppers bifenazate bell peppers difenoconazole bell peppers * remember the extracted ion chromatograms using trusted triple quad fragments

21 B 3707 compound matrix ABSciex Exactive 5500 plus quantitation quantitation (μg/g) (μg/g) percent difference exact mass (H+ adduct, Da) measured mass (Da) mass error (ppm) phorate sulfoxide potatoe trifloxystrobin strawberry pyrimethanil strawberry novaluron strawberry propamocarb squash pyraclostrobin bell pepper pyraclostrobin tomato pyraclostrobin strawberry penthiopyrad bean propamocarb cucumber

22 propoxur (internal control) from B 3707 measured mass of propoxur +H + ppm error average error

23 summary information of real samples f ~ 125 samples screened for ~ 250 pesticides per sample on the Exactive Plus we found: no false positives when compared to ms/ms analysis on an ABSciex 5500 (everything confirmed) no false negatives when compared to an ABSciex 5500 (Exactive Plus did not miss anything at the established LDs) the largest percent difference and average percent difference in quantitation between the Exactive Plus and the ABSciex 5500 was 60 and 4 respectively. one false positive on the ABSciex 5500 (not their fault)

24 real sample false positive realized 302.1/97.2 fenhexamid B3716_R1_01_57782 intensity (arb) 302.1/55.0 fenhexamid B3716_R1_01_ E E 6 extracted ion chromatogram of fenhexamid +H + on Exactive Plus B 3716_R1_01_57782 Time

25 outline ur Goal identify and quantify quickly and reliably UHPLC v HPLC easy and cost effective improvement ur Two Platforms rbitrap and Triple Quad advantages of high resolution MS on the Exactive rbitrap high resolution and high mass accuracy allows for post acquisition data mining limitations of high resolution MS on the Exactive cannot separate compounds with same exact masses no mass filtering fragments can be produced from any ions in the cell Resolution elucidate fragment formulas and structures use trusted triple quad fragments even though their identities are often unknown Exactive Plus vs. ABSciex real samples detection quantitation false positive realized Current and Future Strategies

26 our current strategy and flow if no detections screen with Exactive Plus for ~250 compounds if analyte found above LD report report using ABSciex 5500 identification and quantitation using ms/ms, ion ratios and a 6 point calibration curve

27 our next strategy and flow if analyte found at <.5 tolerance screen with Exactive Plus for ~500 compounds if analyte found at >.5 tolerance report report using ABSciex 5500 estimate and characterization- 1 point calibration standard, and characteristic fragments for confirmation identification and quantitation using ms/ms, ion ratios and a 6 point calibration curve

28 our following strategy and flow if analyte found at < tolerance screen with Exactive Plus for ~750 compounds if analyte found at > tolerance Exactive Plus report using ABSciex 5500 quantitation and characterization- 6 point calibration curve, and characteristic fragments for confirmation identification and quantitation using ms/ms, ion ratios and a 6 point calibration curve

29 our ideal strategy and flow routine screen with Exactive Plus for ~1000 compounds if needed/special case Exactive Plus report using ABSciex 5500 quantitation and characterization- 6 point calibration curve, and characteristic fragments for confirmation identification and quantitation using ms/ms, ion ratios and a 6 point calibration curve

30 acknowledgements Walter Hammack Ghislain Gerard Casey Burrows Erin McAllister Jon Pelt

Overview. Introduction

Overview. Introduction Comprehensive Quantitation and Identification of Pesticides in Food Samples Using the SCIEX UltraLC 100 and the SCIEX QTRAP 4500 System André Schreiber SCIEX, Concord, Ontario, Canada Overview Liquid Chromatography

More information

Advanced Data Acquisition and Data Processing Workflows to Identify, Quantify and Confirm Pesticide Residues

Advanced Data Acquisition and Data Processing Workflows to Identify, Quantify and Confirm Pesticide Residues Advanced Data Acquisition and Data Processing Workflows to Identify, Quantify and Confirm Pesticide Residues André Schreiber 1 and Lauryn Bailey 2 1 AB SCIEX Concord, Ontario (Canada); 2 AB SCIEX Framingham,

More information

Charles Yang, Dipankar Ghosh, Jonathan Beck Thermo Fisher Scientific, San Jose, CA, USA

Charles Yang, Dipankar Ghosh, Jonathan Beck Thermo Fisher Scientific, San Jose, CA, USA Utilization of High Resolution LC-MS for Screening and Quantitative Analysis of Pesticides in Food Matrix using a Q Exactive Benchtop Orbitrap Platform Charles Yang, Dipankar Ghosh, Jonathan Beck Thermo

More information

Food & Environmental. Overview. Introduction. Method Details. André Schreiber and Yun Yun Zou SCIEX, Concord, Ontario, Canada

Food & Environmental. Overview. Introduction. Method Details. André Schreiber and Yun Yun Zou SCIEX, Concord, Ontario, Canada Food & Environmental Comprehensive Quantitation and Identification of Pesticides in Food Samples using LC-MS/MS with Scheduled MRM, Fast Polarity Switching, and MS/MS Library Searching André Schreiber

More information

Applying MRM Spectrum Mode and Library Searching for Enhanced Reporting Confidence in Routine Pesticide Residue Analysis

Applying MRM Spectrum Mode and Library Searching for Enhanced Reporting Confidence in Routine Pesticide Residue Analysis PO-CON1768E Applying MRM Spectrum Mode and Library Searching for Enhanced Reporting Confidence in Routine Pesticide ASMS 2017 TP-194 David Baker 1, Christopher Titman 1, Neil Loftus 1, Jonathan Horner

More information

DETERMINATION OF PESTICIDES IN FOOD USING UPLC WITH POLARITY SWITCHING TANDEM QUADRUPOLE LC/MS/MS

DETERMINATION OF PESTICIDES IN FOOD USING UPLC WITH POLARITY SWITCHING TANDEM QUADRUPOLE LC/MS/MS DETERMINATION OF PESTICIDES IN FOOD USING UPLC WITH POLARITY SWITCHING TANDEM QUADRUPOLE LC/MS/MS Peter Hancock 1, Cristiana C. Leandro 2,3, Brendan J. Keely 2 and Richard J. Fussell 3 1 Waters Corporation,

More information

Overview. Introduction. André Schreiber 1 and Yun Yun Zou 1 1 AB SCIEX, Concord, Ontario, Canada

Overview. Introduction. André Schreiber 1 and Yun Yun Zou 1 1 AB SCIEX, Concord, Ontario, Canada LC-MS/MS Based Strategy for the Non-Targeted Screening of an Unlimited Number of Contaminants in Food Using the AB SCIEX TripleTOF 5600 System and Advanced Software Tools André Schreiber 1 and Yun Yun

More information

Overview. Introduction. Method Details. André Schreiber and Yun Yun Zou AB SCIEX, Concord, Ontario, Canada

Overview. Introduction. Method Details. André Schreiber and Yun Yun Zou AB SCIEX, Concord, Ontario, Canada Comprehensive Quantitation and Identification of Pesticides in Food Samples using LC-MS/MS with Scheduled MRM, Fast Polarity Switching, and MS/MS Library Searching André Schreiber and Yun Yun Zou AB SCIEX,

More information

Rapid Pesticide Screening and Identification Using the High Resolution All Ions MS/MS Technique

Rapid Pesticide Screening and Identification Using the High Resolution All Ions MS/MS Technique Rapid Pesticide Screening and Identification Using the High Resolution All Ions MS/MS Technique Application Note Food Safety Authors Bernhard Wüst and Thomas Glauner Agilent Technologies GmbH Waldbronn

More information

Determination of pesticides in baby food by UHPLC/MS/MS using the Agilent 1290 Infinity LC system and the Agilent 6460 triple quadrupole LC/MS

Determination of pesticides in baby food by UHPLC/MS/MS using the Agilent 1290 Infinity LC system and the Agilent 6460 triple quadrupole LC/MS Determination of pesticides in baby food by UHPLC/MS/MS using the Agilent 1290 Infinity LC system and the Agilent 6460 triple quadrupole LC/MS Application Note Food Authors Gerd Vanhoenacker, Frank David,

More information

Ultra-fast screening of pesticides in foods and agricultural products with desorption corona beam ionization (DCBI) tandem mass spectrometry

Ultra-fast screening of pesticides in foods and agricultural products with desorption corona beam ionization (DCBI) tandem mass spectrometry PO-CON18E Ultra-fast screening of pesticides in foods and agricultural products with desorption corona beam ionization (DCBI) ASMS 21 TP 3 Jing Dong, Satoshi Yamaki, Yuki Hashi, Naoki Hamada Shimadzu China,

More information

Multiresidue Analysis of 100 Pesticides in Food Samples by LC/Triple Quadrupole Mass Spectrometry Application

Multiresidue Analysis of 100 Pesticides in Food Samples by LC/Triple Quadrupole Mass Spectrometry Application Multiresidue Analysis of Pesticides in Food Samples by LC/Triple Quadrupole Mass Spectrometry Application Food Safety Authors Imma Ferrer and E. Michael Thurman Pesticide Residue Research Group University

More information

Higher Confidence in Identification with QTRAP LC/MS/MS Systems when Screening and Quantifying Pesticides in Fruit and Vegetable Samples

Higher Confidence in Identification with QTRAP LC/MS/MS Systems when Screening and Quantifying Pesticides in Fruit and Vegetable Samples Higher Confidence in Identification with QTRAP LC/MS/MS Systems when Screening and Quantifying Pesticides in Fruit and Vegetable Samples André Schreiber AB SCIEX, Concord, Ontario, Canada Figure 1. Ion

More information

Yun W. Alelyunas, Mark D. Wrona, Russell J. Mortishire-Smith, Nick Tomczyk, and Paul D. Rainville Waters Corporation, Milford, MA, USA INTRODUCTION

Yun W. Alelyunas, Mark D. Wrona, Russell J. Mortishire-Smith, Nick Tomczyk, and Paul D. Rainville Waters Corporation, Milford, MA, USA INTRODUCTION Quantitation by High Resolution Mass Spectrometry: Using Target Enhancement and Tof-MRM to Achieve Femtogram-level On-column Sensitivity for Quantitation of Drugs in Human Plasma Yun W. Alelyunas, Mark

More information

Multi-residue analysis of pesticides by GC-HRMS

Multi-residue analysis of pesticides by GC-HRMS An Executive Summary Multi-residue analysis of pesticides by GC-HRMS Dr. Hans Mol is senior scientist at RIKILT- Wageningen UR Introduction Regulatory authorities throughout the world set and enforce strict

More information

Quan/Qual Analyses. Unmatched Confidence for. Thermo Scientific Q Exactive Orbitrap LC-MS/MS System. Identify Quantify Confirm

Quan/Qual Analyses. Unmatched Confidence for. Thermo Scientific Q Exactive Orbitrap LC-MS/MS System. Identify Quantify Confirm 26.1645 165.91 33.267 Thermo Scientific Q Exactive rbitrap LC-MS/MS System Unmatched Confidence for Quan/Qual Analyses Identify Quantify Confirm Quanfirmation \ kwän-f r-'m -shän\ n 1 : the ability to

More information

Quantitation of High Resolution MS Data Using UNIFI: Acquiring and Processing Full Scan or Tof-MRM (Targeted HRMS) Datasets for Quantitative Assays

Quantitation of High Resolution MS Data Using UNIFI: Acquiring and Processing Full Scan or Tof-MRM (Targeted HRMS) Datasets for Quantitative Assays : Acquiring and Processing Full Scan or Tof-MRM (Targeted HRMS) Datasets for Quantitative Assays Mark Wrona, Jayne Kirk, and Yun Alelyunas Waters Corporation, Milford, MA, USA APPLICATION BENEFITS Ability

More information

Theory and Practical Consequences.

Theory and Practical Consequences. Theory and Practical Consequences. Number of hits depending on reachable mass accuracy 250 hits @ ±10 ppm 137 hits @ ±5 ppm 78 hits @ ±3 ppm 29 hits @ ±1 ppm 3 hits @ ±0.1 ppm 1 hit @ ± 0.05 ppm Intens.

More information

Analysis of Pesticides in Citrus Oil Using a Shimadzu GCMS-TQ8030. No. GCMS No. SSI-GCMS-1404

Analysis of Pesticides in Citrus Oil Using a Shimadzu GCMS-TQ8030. No. GCMS No. SSI-GCMS-1404 Gas Chromatograph Mass Spectrometer No. GCMS-1404 Analysis of Pesticides in Citrus Oil Using a Shimadzu GCMS-TQ8030 Introduction Contamination of consumer products with pesticides is a growing concern

More information

PesticideScreener. Innovation with Integrity. Comprehensive Pesticide Screening and Quantitation UHR-TOF MS

PesticideScreener. Innovation with Integrity. Comprehensive Pesticide Screening and Quantitation UHR-TOF MS PesticideScreener Comprehensive Pesticide Screening and Quantitation Innovation with Integrity UHR-TOF MS The Challenge of Comprehensive Pesticide Residue Analysis The use of pesticides to reduce crop

More information

TOMAHAQ Method Construction

TOMAHAQ Method Construction TOMAHAQ Method Construction Triggered by offset mass accurate-mass high-resolution accurate quantitation (TOMAHAQ) can be performed in the standard method editor of the instrument, without modifications

More information

Pesticides in Cannabis

Pesticides in Cannabis LCMS-8040 Application Pesticides in Cannabis Jeff Dahl, 1 Julie Kowalski, 2 Jason Zitzer, 3 and Gordon Fagras 3 1 Shimadzu Scientific Instruments; Columbia, Maryland 2 Restek Corporation; Bellefonte, Pennsylvania

More information

dynamic MRM for pesticide analysis

dynamic MRM for pesticide analysis The power of fast separation and dynamic MRM for pesticide analysis based on 1290/6460QQQ Dr. Volker Gnau Produkt Spezialist LCMS Page 1 3.) Quantitative analysis of pesticides (smrm) Chromatographic hi

More information

LC/MS/MS Analysis of Pesticide Residues in Apples Using Agilent Chem Elut Cartridges

LC/MS/MS Analysis of Pesticide Residues in Apples Using Agilent Chem Elut Cartridges LC/MS/MS Analysis of Pesticide Residues in Apples Using Agilent Chem Elut Cartridges Application ote Food Testing & Agriculture Author Andy Zhai Agilent Technologies Shanghai Co. Ltd. Abstract This application

More information

WADA Technical Document TD2003IDCR

WADA Technical Document TD2003IDCR IDENTIFICATION CRITERIA FOR QUALITATIVE ASSAYS INCORPORATING CHROMATOGRAPHY AND MASS SPECTROMETRY The appropriate analytical characteristics must be documented for a particular assay. The Laboratory must

More information

Simplified Workflow and Improved Confidence in Screening Methods on Time of Flight Mass Spectrometry

Simplified Workflow and Improved Confidence in Screening Methods on Time of Flight Mass Spectrometry Simplified Workflow and Improved Confidence in Screening Methods on Time of Flight Mass Spectrometry Steve Preece MS Business Manager Waters Wilmslow 2016 Waters Corporation 1 Overview Use of high resolution

More information

Analysis of Pesticides in Baby Foods Using a Triple-Quadrupole GC/MS/MS

Analysis of Pesticides in Baby Foods Using a Triple-Quadrupole GC/MS/MS PO-CONE Analysis of Pesticides in Baby Foods Using a Pittcon 01 -P Laura Chambers, Richard Whitney, Ph.D., Nicole M. Lock, Zhuangzhi Max Wang, Ph.D., Clifford M. Taylor; Shimadzu Scientific Instruments,

More information

Pure Chromatography. Food Safety Applications. Abstract. Introduction

Pure Chromatography. Food Safety Applications.  Abstract. Introduction Food Safety Applications Mitigating Matrix Effects: Examination of Dilution, QuEChERS, and Calibration Strategies for LC-MS/MS Analysis of Pesticide Residues in Diverse Food Types Abstract By Julie Kowalski,

More information

Analysis of Pesticides and Contaminants using HS-SPME-GC/MS and DRS Detection. Blair Surridge, Tyler Dyer, Rene Bilideau, Paloma Bertolin Presoti

Analysis of Pesticides and Contaminants using HS-SPME-GC/MS and DRS Detection. Blair Surridge, Tyler Dyer, Rene Bilideau, Paloma Bertolin Presoti Analysis of Pesticides and Contaminants using HS-SPME-GC/MS and DRS Detection Blair Surridge, Tyler Dyer, Rene Bilideau, Paloma Bertolin Presoti Applied Research at Camosun College Provides funding to

More information

2016 iquan Series: Pesticide Quantitation on the Thermo Scientific TSQ Quantiva

2016 iquan Series: Pesticide Quantitation on the Thermo Scientific TSQ Quantiva 2016 iquan Series: Pesticide Quantitation on the Thermo Scientific TSQ Quantiva Craig Dufresne and Kevin McHale, Content Creators The world leader in serving science The Whole Workflow Efficiency in sample

More information

Comprehensive Pesticide Analysis in Juice Using a Combination of GC/MS and LC/MS Methods

Comprehensive Pesticide Analysis in Juice Using a Combination of GC/MS and LC/MS Methods Comprehensive Pesticide Analysis in Juice Using a Combination of GC/MS and LC/MS Methods Application Note Food Safety Authors Fadwa Al-Taher, Rima Juskelis, Yang Chen, Jack Cappozzo Institute for Food

More information

Multi-residue GC-MS analysis. Richard Fussell CSL York, UK

Multi-residue GC-MS analysis. Richard Fussell CSL York, UK Multi-residue GC-MS analysis Richard Fussell CSL York, UK e-mail: r.fussell@csl.gov.uk Outline of Presentation Background Gas Chromatography Mass Spectrometry - Options Capabilities and Applications Summary

More information

Application News. No. C154. Applying MRM Spectrum Mode and Library Searching for Enhanced Reporting Confidence in Routine Pesticide Residue Analysis

Application News. No. C154. Applying MRM Spectrum Mode and Library Searching for Enhanced Reporting Confidence in Routine Pesticide Residue Analysis LAAN-A-LM-E124 Application Liquid Chromatography Mass Spectrometry Applying MRM Spectrum Mode and Library Searching for Enhanced Reporting Confidence in Routine Pesticide Residue Analysis David R. Baker

More information

LC-HRMS: Challenges for Routine Implementation

LC-HRMS: Challenges for Routine Implementation Joint EURL pesticides meeting October 23 rd -25th, 2013 Almeria Spain LC-HRMS: Challenges for Routine Implementation Richard J. Fussell Food and Environment Research Agency (York, UK) www.fera.defra.gov.uk

More information

LC-MS/MS multiresidue method used for pesticides analysis in fruits and vegetables

LC-MS/MS multiresidue method used for pesticides analysis in fruits and vegetables LC-MS/MS multiresidue method used for pesticides analysis in fruits and vegetables 1st International Symposium on Recent Advances in Food Analysis 5-7 ovember 2003, Prague Didier RTELLI, Patrick EDDER,

More information

Date ACCURATE-MASS DATABASE FOR SCREENING OF PESTICIDE RESIDUES IN FRUITS AND VEGETABLES BY GAS CHROMATOGRAPHY TIME-OF-FLIGHT MASS SPECTROMETRY

Date ACCURATE-MASS DATABASE FOR SCREENING OF PESTICIDE RESIDUES IN FRUITS AND VEGETABLES BY GAS CHROMATOGRAPHY TIME-OF-FLIGHT MASS SPECTROMETRY Date ACCURATE-MASS DATABASE FOR SCREENING OF PESTICIDE RESIDUES IN FRUITS AND VEGETABLES BY GAS CHROMATOGRAPHY TIME-OF-FLIGHT MASS SPECTROMETRY In practice, target analysis approach (analysing 1-4 of GC

More information

New Dynamic MRM Mode Improves Data Quality and Triple Quad Quantification in Complex Analyses

New Dynamic MRM Mode Improves Data Quality and Triple Quad Quantification in Complex Analyses New Dynamic MRM Mode Improves Data Quality and Triple Quad Quantification in Complex Analyses Technical Overview Authors Abstract Peter Stone, Thomas Glauner, Frank Kuhlmann, Tim Schlabach and Ken Miller

More information

Theory of Sampling. Guide to Quality Sample Processing. Jo Marie Cook NACRW 2015

Theory of Sampling. Guide to Quality Sample Processing. Jo Marie Cook NACRW 2015 Theory of Sampling Guide to Quality Sample Processing Jo Marie Cook NACRW 2015 2011 Food Safety Modernization Act Integrated Food Safety System Section 202(a)(6): Standards for Sampling and Testing Partnership

More information

Types of Analyzers: Quadrupole: mass filter -part1

Types of Analyzers: Quadrupole: mass filter -part1 16 Types of Analyzers: Sector or double focusing: magnetic and electric Time-of-flight (TOF) Quadrupole (mass filter) Linear ion trap Quadrupole Ion Trap (3D trap) FTICR fourier transform ion cyclotron

More information

Analytical Test Report 10

Analytical Test Report 10 OLCC #022892C 9 SE Division St. Laboratory ID: 805024-02 Batch ID: AC Date Sampled: 05/07/8 Date Printed: 05//8 Report cannot be used for OLCC/OHA compliance. Date Sampled: 05/07/8 00:00 Date Accepted:

More information

László Tölgyesi LC/MS scientist EFSC Demo Group. International Symposium on Food Safety and Quality: Applications of Nuclear and Related Techniques

László Tölgyesi LC/MS scientist EFSC Demo Group. International Symposium on Food Safety and Quality: Applications of Nuclear and Related Techniques Minimizing matrix effects in multiresidue pesticide analysis using a new sensitivity-enhanced triple quadrupole instrument in combination with extensive sample dilution László Tölgyesi LC/MS scientist

More information

Screening Validation Report 1

Screening Validation Report 1 EURL for Cereals and Feeding stuff National Food Institute Technical University of Denmark Appendix 4 Screening Validation Report 1 Screening of pesticide residues in cereals by UPLC-TOF (QuEChERS method)

More information

LC/Q-TOF Workflows for Comprehensive Micropollutant Analysis

LC/Q-TOF Workflows for Comprehensive Micropollutant Analysis LC/Q-TO Workflows for Comprehensive Micropollutant Analysis Targeted Quantification, Suspect Screening, and Unknown Compound Identification Application Note Environmental Authors Christoph Moschet and

More information

AB SCIEX SelexION Technology Used to Improve Mass Spectral Library Searching Scores by Removal of Isobaric Interferences

AB SCIEX SelexION Technology Used to Improve Mass Spectral Library Searching Scores by Removal of Isobaric Interferences AB SCIEX SelexION Technology Used to Improve Mass Spectral Library Searching s by Removal of Isobaric Interferences Differential Mobility Used as a Tool to Address Selectivity Challenges Adrian M. Taylor

More information

Liquid Chromatography Mass Spectrometry. Expanding Capabilities in Multi-Residue Pesticide Analysis Using The LCMS-8060

Liquid Chromatography Mass Spectrometry. Expanding Capabilities in Multi-Residue Pesticide Analysis Using The LCMS-8060 LAAN-A-LM-E107 Application Liquid Chromatography Mass Spectrometry Expanding Capabilities in Multi-Residue Pesticide Analysis Using The LCMS-8060 David R. Baker 1, Laëtitia Fages 2, Eric Capodanno 2, Neil

More information

Application Note LCMS-110 Development of a Targeted Quantitative LC-MS/MS Method for 431 Positive and Negative Ion Pesticides in a Single Analysis

Application Note LCMS-110 Development of a Targeted Quantitative LC-MS/MS Method for 431 Positive and Negative Ion Pesticides in a Single Analysis Application Note LCMS-110 Development of a Targeted Quantitative LC-MS/MS Method for 431 Positive and Negative Ion Pesticides in a Single Analysis Abstract A rapid, targeted quantitative UHPLC-triple quadrupole

More information

Increasing Speed of UHPLC-MS Analysis Using Single-stage Orbitrap Mass Spectrometer

Increasing Speed of UHPLC-MS Analysis Using Single-stage Orbitrap Mass Spectrometer Increasing Speed of UHPLC-MS Analysis Using Single-stage Orbitrap Mass Spectrometer Olaf Scheibner and Maciej Bromirski Thermo Fisher Scientific, Bremen, Germany Overview Purpose: Improve the performance

More information

Tyler Trent, Applications Sales Specialist, Teledyne Tekmar P a g e 1

Tyler Trent, Applications Sales Specialist, Teledyne Tekmar P a g e 1 Application Note AutoMate-Q40 Automated QuEChERS Extraction for Pesticide Residues in Botanicals Tyler Trent, Applications Sales Specialist, Teledyne Tekmar P a g e 1 Abstract QuEChERS is a Quick-Easy-Cheap-

More information

Overview. Introduction. André Schreiber AB SCIEX Concord, Ontario (Canada)

Overview. Introduction. André Schreiber AB SCIEX Concord, Ontario (Canada) Quantitation and Identification of Pharmaceuticals and Personal Care Products (PPCP) in Environmental Samples using Advanced TripleTOF MS/MS Technology André Schreiber AB SCIEX Concord, Ontario (Canada)

More information

Utility of H-SRM to Reduce Matrix Interference in Food Residue Analysis of Pesticides by LC-MS/MS Using the TSQ Quantum Discovery

Utility of H-SRM to Reduce Matrix Interference in Food Residue Analysis of Pesticides by LC-MS/MS Using the TSQ Quantum Discovery Application Note: 3 Utility of H-SRM to Reduce Matrix Interference in Food Residue Analysis of Pesticides by LC-MS/MS Using the TSQ Quantum Discovery Yoko Yamagishi, Thermo Fisher Scientific, C-2F 3-9

More information

Improved Screening for 250 Pesticides in Matrix using a LC-Triple Quadrupole Mass Spectrometer

Improved Screening for 250 Pesticides in Matrix using a LC-Triple Quadrupole Mass Spectrometer Improved Screening for 2 Pesticides in Matrix using a LC-Triple Quadrupole Mass Spectrometer Mary lackburn, Jia Wang, Jonathan eck, Charles Yang, Dipankar Ghosh, Thermo Fisher Scientific, San Jose, C,

More information

Simplified Approaches to Impurity Identification using Accurate Mass UPLC/MS

Simplified Approaches to Impurity Identification using Accurate Mass UPLC/MS Simplified Approaches to Impurity Identification using Accurate Mass UPLC/MS Marian Twohig, Michael D. Jones, Dominic Moore, Peter Lee, and Robert Plumb Waters Corporation, Milford, MA, USA APPLICATION

More information

Quantitative and Qualitative Confirmation of Pesticides in Beet Extract Using a Hybrid Quadrupole-Orbitrap Mass Spectrometer

Quantitative and Qualitative Confirmation of Pesticides in Beet Extract Using a Hybrid Quadrupole-Orbitrap Mass Spectrometer Quantitative and Qualitative Confirmation of Pesticides in Beet Extract Using a Hybrid Quadrupole-Orbitrap Mass Spectrometer Charles Yang and Dipankar Ghosh, Thermo Fisher Scientific, San Jose, CA Olaf

More information

An Effective Workflow for Impurity Analysis Incorporating High Quality HRAM LCMS & MSMS with Intelligent Automated Data Mining

An Effective Workflow for Impurity Analysis Incorporating High Quality HRAM LCMS & MSMS with Intelligent Automated Data Mining An Effective Workflow for Impurity Analysis Incorporating High Quality HRAM LCMS & MSMS with Intelligent Automated Data Mining Dave Weil, Ph.D. and Jim Lau, Ph.D. Typical Method Conditions: 1260 UHPLC

More information

THE IMPLEMENTATION OF A SCREENING WORKFLOW FOR ION MOBILITY QUADRUOPOLE TIME-OF-FLIGHT MASS SPECTROMETRIC ANALYSIS OF PFOS ISOMERS

THE IMPLEMENTATION OF A SCREENING WORKFLOW FOR ION MOBILITY QUADRUOPOLE TIME-OF-FLIGHT MASS SPECTROMETRIC ANALYSIS OF PFOS ISOMERS THE IMPLEMENTATION O A SCREENING WORKLOW OR ION MOBILITY QUADRUOPOLE TIME-O-LIGHT MASS SPECTROMETRIC ANALYSIS O POS ISOMERS Ken Rosnack ken_rosnack@waters.com Ingrid Ericson Jogsten and Bert van Bavel

More information

The Emergence of Benchtop Tandem Quadrupole Mass Spectrometers as a Routine Tool in Quantitative GC/MS/MS Applications

The Emergence of Benchtop Tandem Quadrupole Mass Spectrometers as a Routine Tool in Quantitative GC/MS/MS Applications The Emergence of Benchtop Tandem Quadrupole Mass Spectrometers as a Routine Tool in Quantitative GC/MS/MS Applications Doug Stevens Waters Corp. Introduction The range of GC/MS instrument types has expanded

More information

Identification and Characterization of an Isolated Impurity Fraction: Analysis of an Unknown Degradant Found in Quetiapine Fumarate

Identification and Characterization of an Isolated Impurity Fraction: Analysis of an Unknown Degradant Found in Quetiapine Fumarate Identification and Characterization of an Isolated Impurity Fraction: Analysis of an Unknown Degradant Found in Quetiapine Fumarate Michael D. Jones, Xiang Jin Song, Robert S. Plumb, Peter J. Lee, and

More information

Multiple Fragmentation Methods for Small Molecule Characterization on a Dual Pressure Linear Ion Trap Orbitrap Hybrid Mass Spectrometer

Multiple Fragmentation Methods for Small Molecule Characterization on a Dual Pressure Linear Ion Trap Orbitrap Hybrid Mass Spectrometer Application ote: 54 Multiple Fragmentation Methods for Small Molecule Characterization on a Dual Pressure Linear Ion Trap rbitrap Hybrid Mass Spectrometer Kate Comstock, Yingying Huang; Thermo Fisher Scientific,

More information

Screening of pesticides residues by the time of flight analyzer (ToF) : Myth or reality?

Screening of pesticides residues by the time of flight analyzer (ToF) : Myth or reality? Screening of pesticides residues by the time of flight analyzer (ToF) : Myth or reality? Laure Joly & Vincent Hanot WIV-ISP, Juliette Wytsmanstraat 14, 15 Brussel The passengers pesticides are requested......

More information

Q-TOF PREMIER DYNAMIC RANGE ENHANCEMENT AND ACCURATE MASS MEASUREMENT PERFORMANCE

Q-TOF PREMIER DYNAMIC RANGE ENHANCEMENT AND ACCURATE MASS MEASUREMENT PERFORMANCE Q-TOF PREMIER DYAMIC RAGE EHACEMET AD ACCURATE MASS MEASUREMET PERFORMACE Michael McCullagh, Jose Castro-Perez, and Lisa Calton Waters Corporation, Manchester, UK ITRODUCTIO The use of time-of-flight (TOF)

More information

Determination of Pesticide Residues in Oats by Automated. QuEChERS and LC/QQQ. Application Note. Abstract. Introduction

Determination of Pesticide Residues in Oats by Automated. QuEChERS and LC/QQQ. Application Note. Abstract. Introduction Determination of Pesticide Residues in Oats by Automated QuEChERS and LC/QQQ Application Note Abstract The QuEChERS (Quick-Easy-Cheap-Effective-Rugged-Safe) sample extraction method was developed for the

More information

Application of a Triggered MRM Database and Library for the Quantitation and Identification of Pesticides in Food Extracts

Application of a Triggered MRM Database and Library for the Quantitation and Identification of Pesticides in Food Extracts Application of a Triggered MRM Database and Library for the Quantitation and Identification of Pesticides in Food Extracts Application Note Food Authors Thomas Glauner Agilent Technologies, Inc. Waldbronn,

More information

Rapid and Accurate Forensics Analysis using High Resolution All Ions MS/MS

Rapid and Accurate Forensics Analysis using High Resolution All Ions MS/MS Rapid and Accurate Forensics Analysis using High Resolution All Ions MS/MS Application Note Forensic Toxicology Authors Martin Josefsson, and Markus Roman National Board of Forensic Medicine Linköping,

More information

Determination of Pesticide Multiresidues in Apple, Pear and Grape using modified QuEChERS and analysis by LC-QTOF MS

Determination of Pesticide Multiresidues in Apple, Pear and Grape using modified QuEChERS and analysis by LC-QTOF MS Determination of Pesticide Multiresidues in Apple, Pear and Grape using modified QuEChERS and analysis by LC-QTOF MS Application Note Authors Renato Zanella, Juliana S. Munaretto, and Manoel L. Martins

More information

Analytical Technologies and Compound Identification. Daniel L. Norwood, MSPH, PhD SCĪO Analytical Consulting, LLC.

Analytical Technologies and Compound Identification. Daniel L. Norwood, MSPH, PhD SCĪO Analytical Consulting, LLC. Analytical Technologies and Compound Identification Daniel L. Norwood, MSPH, PhD SCĪ Analytical Consulting, LLC. Extractables/Leachables Characterization (USP) Characterization is the discovery,

More information

Mass Spectrometry. Hyphenated Techniques GC-MS LC-MS and MS-MS

Mass Spectrometry. Hyphenated Techniques GC-MS LC-MS and MS-MS Mass Spectrometry Hyphenated Techniques GC-MS LC-MS and MS-MS Reasons for Using Chromatography with MS Mixture analysis by MS alone is difficult Fragmentation from ionization (EI or CI) Fragments from

More information

Application Note. Abstract. Authors. Food Safety and Environmental

Application Note. Abstract. Authors. Food Safety and Environmental Multi-Residue Pesticide Analysis with Dynamic Multiple Reaction Monitoring and Triple Quadrupole LC/MS/MS Fast and Effective Method Development Using an Application Kit and a Pesticides Compound Parameter

More information

High Efficiency, Broad Scope Screening of Pesticides Using Gas Chromatography High Resolution Orbitrap Mass Spectrometry

High Efficiency, Broad Scope Screening of Pesticides Using Gas Chromatography High Resolution Orbitrap Mass Spectrometry High Efficiency, Broad Scope Screening of Pesticides Using Gas Chromatography High Resolution Orbitrap Mass Spectrometry Dominic Roberts,1 Hans Mol,2 Marc Tienstra,2 Cristian Cojocariu,1 and Paul Silcock1

More information

Qualitative and Quantitative Analysis of Pesticides in Horse Feed Matrix Using Orbitrap MS

Qualitative and Quantitative Analysis of Pesticides in Horse Feed Matrix Using Orbitrap MS Qualitative and Quantitative Analysis of esticides in Horse Feed Matrix Using rbitrap M laf cheibner and Maciej Bromirski, Thermo Fisher cientific, Bremen, Germany Application Note 573 Key Words Exactive

More information

Powerful Scan Modes of QTRAP System Technology

Powerful Scan Modes of QTRAP System Technology Powerful Scan Modes of QTRAP System Technology Unique Hybrid Triple Quadrupole Linear Ion Trap Technology Provides Powerful Workflows to Answer Complex Questions with No Compromises While there are many

More information

Introduction to the Q Trap LC/MS/MS System

Introduction to the Q Trap LC/MS/MS System www.ietltd.com Proudly serving laboratories worldwide since 1979 CALL +1.847.913.0777 for Refurbished & Certified Lab Equipment ABI Q Trap LC/MS/MS Introduction to the Q Trap LC/MS/MS System The Q Trap

More information

TargetScreener. Innovation with Integrity. A Comprehensive Screening Solution for Forensic Toxicology UHR-TOF MS

TargetScreener. Innovation with Integrity. A Comprehensive Screening Solution for Forensic Toxicology UHR-TOF MS TargetScreener A Comprehensive Screening Solution for Forensic Toxicology Innovation with Integrity UHR-TOF MS TargetScreener Get the Complete Picture Forensic laboratories are frequently required to perform

More information

Agilent ESI and APCI sources: for polar to non-polar compounds

Agilent ESI and APCI sources: for polar to non-polar compounds 1 Agilent 6400 Series Triple Quadrupole Users Workshop 1 Agilent ESI and APCI sources: for polar to non-polar compounds Nebulizer Pressure Corona current Nebulizer Pressure Vaporizer Vcap Vcap Drying Gas

More information

TANDEM MASS SPECTROSCOPY

TANDEM MASS SPECTROSCOPY TANDEM MASS SPECTROSCOPY 1 MASS SPECTROMETER TYPES OF MASS SPECTROMETER PRINCIPLE TANDEM MASS SPECTROMETER INSTRUMENTATION QUADRAPOLE MASS ANALYZER TRIPLE QUADRAPOLE MASS ANALYZER TIME OF FLIGHT MASS ANALYSER

More information

MassHunter TOF/QTOF Users Meeting

MassHunter TOF/QTOF Users Meeting MassHunter TOF/QTOF Users Meeting 1 Qualitative Analysis Workflows Workflows in Qualitative Analysis allow the user to only see and work with the areas and dialog boxes they need for their specific tasks

More information

Fully automated QuEChERS clean-up and LC/MS-QQQ analysis of pesticides in fruits and vegetables.

Fully automated QuEChERS clean-up and LC/MS-QQQ analysis of pesticides in fruits and vegetables. Chromatography Technical Note No AS90 Fully automated QuEChERS clean-up and LC/MS-QQQ analysis of pesticides in fruits and vegetables. Paul H. Roberts, Anatune Ltd. Hardwick, Cambridgeshire, UK. Introduction

More information

Routine Multiresidue Pesticide Analysis using the Agilent 6470 Triple Quadrupole Mass Spectrometer

Routine Multiresidue Pesticide Analysis using the Agilent 6470 Triple Quadrupole Mass Spectrometer Routine Multiresidue Pesticide Analysis using the Agilent 6470 Triple Quadrupole Mass Spectrometer Application Note Food safety Authors Mark Sartain and Anabel Fandino Agilent Technologies, Inc. Santa

More information

5Cl-AKB48 and 5Br-AKB48

5Cl-AKB48 and 5Br-AKB48 NMS Labs 2300 Stratford Ave Willow Grove, PA 19090 5Cl-AKB48 and 5Br-AKB48 5Cl-AKB48 Sample Type: Seized Material Latest Revision: May 18 th, 2018 Date Received: February 16 th, 2018 Date of Report: April

More information

Metabolomics in an Identity Crisis? Am I a Feature or a Compound? The world leader in serving science

Metabolomics in an Identity Crisis? Am I a Feature or a Compound? The world leader in serving science Metabolomics in an Identity Crisis? Am I a Feature or a Compound? The world leader in serving science Agenda 1 2 3 Unknown Analysis in Metabolomics Determining Features and Compounds for Data Reduction

More information

Screening and Quantitation of 240 Pesticides in Difficult Food Matrixes Using the Agilent 6545 Q-TOF LC/MS System

Screening and Quantitation of 240 Pesticides in Difficult Food Matrixes Using the Agilent 6545 Q-TOF LC/MS System Screening and Quantitation of 24 Pesticides in Difficult Food Matrixes Using the Agilent 6545 Q-TOF LC/MS System Application Note Authors Dan-Hui Dorothy Yang, Christian Klein, Crystal Cody, and Huy Bui

More information

Anaylsis of Pesticide Residues in Rice Using Agilent Bond Elut QuEChERS AOAC Kit by LC-MS/MS Detection

Anaylsis of Pesticide Residues in Rice Using Agilent Bond Elut QuEChERS AOAC Kit by LC-MS/MS Detection Anaylsis of Pesticide Residues in Rice Using Agilent Bond Elut QuEChERS AOAC Kit by LC-MS/MS Detection Application Note Food Safety Author Andy Zhai Agilent technologies Co., Ltd. 412 Yinglun Road Shanghai,

More information

QTRAP Technology A COMPENDIUM OF RELATED RESEARCH APPLICATIONS

QTRAP Technology A COMPENDIUM OF RELATED RESEARCH APPLICATIONS QTRAP Technology A COMPENDIUM OF RELATED RESEARCH APPLICATIONS QTRAP Technology Discover QTRAP, the only triple quadrupole technology in the world powered by a linear ion trap (LIT), combining the MRM

More information

Cerno Application Note Extending the Limits of Mass Spectrometry

Cerno Application Note Extending the Limits of Mass Spectrometry June Cerno Application Note Extending the Limits of Mass Spectrometry Accurate Mass Compound Identification with Single Quadrupole GC/MS Yongdong Wang I and Harry Prest II Single Quad GC/MS instruments

More information

Key Words Q Exactive, Accela, MetQuest, Mass Frontier, Drug Discovery

Key Words Q Exactive, Accela, MetQuest, Mass Frontier, Drug Discovery Metabolite Stability Screening and Hotspot Metabolite Identification by Combining High-Resolution, Accurate-Mass Nonselective and Selective Fragmentation Tim Stratton, Caroline Ding, Yingying Huang, Dan

More information

2010 Waters Corporation. Xevo TQ-S for Bioanalysis

2010 Waters Corporation. Xevo TQ-S for Bioanalysis Xevo TQ-S for Bioanalysis Key innovations High Performance Stepwave RADAR Scan Wave Versatility Ion Sources Simplicity of Operation Engineered Simplicity The Xevo TQ family Built on the same foundations

More information

Sensitive and Repeatable Analysis of Pesticides in QuEChERS Extracts with APGC-MS/MS

Sensitive and Repeatable Analysis of Pesticides in QuEChERS Extracts with APGC-MS/MS Sensitive and Repeatable Analysis of Pesticides in QuEChERS Extracts with APGC-MS/MS Dominic Roberts, 1 Sara Stead, 1 and Jennifer A. Burgess 2 1 Waters Corporation, Manchester, UK 2 Waters Corporation,

More information

WADA Technical Document TD2015IDCR

WADA Technical Document TD2015IDCR MINIMUM CRITERIA FOR CHROMATOGRAPHIC-MASS SPECTROMETRIC CONFIRMATION OF THE IDENTITY OF ANALYTES FOR DOPING CONTROL PURPOSES. The ability of a method to identify an analyte is a function of the entire

More information

Analysis of Polar Metabolites using Mass Spectrometry

Analysis of Polar Metabolites using Mass Spectrometry Analysis of Polar Metabolites using Mass Spectrometry TransMed Course: Basics in Clinical Proteomics and Metabolomics. Oct 10-19, 2012 dd.mm.yyyy Vidya Velagapudi, Ph.D, Adjunct Professor Head of the Metabolomics

More information

Improved 6- Plex TMT Quantification Throughput Using a Linear Ion Trap HCD MS 3 Scan Jane M. Liu, 1,2 * Michael J. Sweredoski, 2 Sonja Hess 2 *

Improved 6- Plex TMT Quantification Throughput Using a Linear Ion Trap HCD MS 3 Scan Jane M. Liu, 1,2 * Michael J. Sweredoski, 2 Sonja Hess 2 * Improved 6- Plex TMT Quantification Throughput Using a Linear Ion Trap HCD MS 3 Scan Jane M. Liu, 1,2 * Michael J. Sweredoski, 2 Sonja Hess 2 * 1 Department of Chemistry, Pomona College, Claremont, California

More information

Choosing the metabolomics platform

Choosing the metabolomics platform GBS 748 Choosing the metabolomics platform Stephen Barnes, PhD 4 7117; sbarnes@uab.edu So, I have my samples what s next? You ve collected your samples and you may have extracted them Protein precipitation

More information

All Ions MS/MS: Targeted Screening and Quantitation Using Agilent TOF and Q-TOF LC/MS Systems

All Ions MS/MS: Targeted Screening and Quantitation Using Agilent TOF and Q-TOF LC/MS Systems All Ions MS/MS: Targeted Screening and Quantitation Using Agilent TOF and Q-TOF LC/MS Systems Technical Overview Introduction All Ions MS/MS is a technique that is available for Agilent high resolution

More information

Analytical determination of testosterone in human serum using an Agilent Ultivo Triple Quadrupole LC/MS

Analytical determination of testosterone in human serum using an Agilent Ultivo Triple Quadrupole LC/MS Application Note Clinical Research Analytical determination of testosterone in human serum using an Agilent Ultivo Triple Quadrupole LC/MS Authors Yanan Yang 1, Victor Mandragon 2, and Peter Stone 1 1

More information

Determination of 198 pesticide residues in eggplant using Gas Chromatography tandem Mass Spectrometry/Mass Spectrometry

Determination of 198 pesticide residues in eggplant using Gas Chromatography tandem Mass Spectrometry/Mass Spectrometry PO-CON1619E Determination of 198 pesticide residues in eggplant using Gas Chromatography tandem Mass Spectrometry/Mass Spectrometry Pittcon 2016 480-25 Yan Wang, Feifei Tian, Yueqi Li, Guixiang Yang, Taohong

More information

Analytical Test Report Birthday Cake OG

Analytical Test Report Birthday Cake OG ORELAP #4096 OLCC #1002112892C Science First. 11119 SE Division St. Portland, OR 97266 (503) 307-0096 Analytical Test Report Birthday Cake OG Gardens of Odin 020-1003851CB2B Laboratory ID: 1710112-03 Batch

More information

Tomorrow s quantitation with the TSQ Fortis mass spectrometer: quantitation of phenylephrine hydrochloride for QA/QC laboratories

Tomorrow s quantitation with the TSQ Fortis mass spectrometer: quantitation of phenylephrine hydrochloride for QA/QC laboratories APPLICATION NOTE 65200 Tomorrow s quantitation with the TSQ Fortis mass spectrometer: quantitation of phenylephrine hydrochloride for QA/QC laboratories Authors Neloni Wijeratne, Claudia Martins, Mary

More information

Thermo Scientific Pesticide Explorer Collection. Start-to-finish. workflows for pesticide analysis

Thermo Scientific Pesticide Explorer Collection. Start-to-finish. workflows for pesticide analysis Thermo Scientific Pesticide Explorer Collection Start-to-finish workflows for pesticide analysis Comprehensive Pesticide Analysis Solutions Pesticide Explorer Collection Selection table Lab Profile Routine

More information

Peptide Targeted Quantification By High Resolution Mass Spectrometry A Paradigm Shift? Zhiqi Hao Thermo Fisher Scientific San Jose, CA

Peptide Targeted Quantification By High Resolution Mass Spectrometry A Paradigm Shift? Zhiqi Hao Thermo Fisher Scientific San Jose, CA Peptide Targeted Quantification By High Resolution Mass Spectrometry A Paradigm Shift? Zhiqi Hao Thermo Fisher Scientific San Jose, CA Proteomics is Turning Quantitative Hmmm.. Which ones are my targets?

More information

Highly Sensitive and Rugged GC/MS/MS Tool

Highly Sensitive and Rugged GC/MS/MS Tool Highly Sensitive and Rugged GC/MS/MS Tool For Pesticide Multiresidue Analysis in Food Samples Agilent 7 Series Triple Quadrupole GC/MS. The world s first MS/MS designed specifically for GC Analysis Introduction

More information

A Rapid Approach to the Confirmation of Drug Metabolites in Preclinical and Clinical Bioanalysis Studies

A Rapid Approach to the Confirmation of Drug Metabolites in Preclinical and Clinical Bioanalysis Studies A Rapid Approach to the Confirmation of Drug Metabolites in Preclinical and Clinical Bioanalysis Studies APPLICATION BENEFITS Regulatory guidelines and recommendations place a greater emphasis on the detection

More information

IDENTIFICATION AND QUANTIFICATION OF TRANSFORMATION PRODUCTS IN THE AQUATIC ENVIRONMENT BY HIGH RESOLUTION MASS SPECTROMETRY

IDENTIFICATION AND QUANTIFICATION OF TRANSFORMATION PRODUCTS IN THE AQUATIC ENVIRONMENT BY HIGH RESOLUTION MASS SPECTROMETRY IDETIFICATIO AD QUATIFICATIO OF TRASFORMATIO PRODUCTS I THE AQUATIC EVIROMET BY HIGH RESOLUTIO MASS SPECTROMETRY Juliane Hollender, Rebekka Baumgartner, Kathrin Fenner, Susanne Kern, Philipp Longrée, Heinz

More information