MassHunter TOF/QTOF Users Meeting
|
|
- Osborne Mason
- 5 years ago
- Views:
Transcription
1 MassHunter TOF/QTOF Users Meeting 1
2 Qualitative Analysis Workflows Workflows in Qualitative Analysis allow the user to only see and work with the areas and dialog boxes they need for their specific tasks A Workflow consists of three parts: A default method for the Workflow with the parameters and report templates already set for that type of task. A specified layout of the user interface that only shows the windows and table columns that the user needs to see. A new section at the top of the Method Explorer (called a workflow section) which groups together the tabs a user may need while performing a task: 5
3 Applying a Workflow Configuration Configure for Workflow in the menu bar You will see a warning that applying the Workflow will make changes 7
4 Using a Workflow After applying the Workflow, go through each tab in the workflow section sequentially to adjust the parameters for your task: 8
5 Isotope Distribution Calculator There is a standalone Isotope Distribution Calculator included with Qualitative Analysis at: C:\Program Files\Agilent\MassHunter\Workstation\Qual\B.0x.00\Bin\IsotopeDistributionCalculator.exe. Or under Start menu under: In B or later: All Programs Agilent MassHunter Workstation Qualitative Analysis B.0x.00 Tools It allows you to model the theoretical abundances and spacing of any particular compound: 12
6 How To Determine Complexity of Sample/Matrix Acquire MS or AutoMSMS Modes Base Peak Chromatogram Excludes Major Components reference masses Find Compounds by Molecular Feature Extraction (MFE) Base Peak Chromatogram with Exclude m/z /- 100 ppm 14
7 Find Compounds by Molecular Feature Results Over 280 Compounds Found in Coffee Spiked with Pesticide 15
8 Molecular Feature Extractor (MFE) Transforming Data into Chemical Information Raw data Background noise removed Individual m/z peaks grouped into isotope clusters Isotope clusters grouped into molecular features Identification, Quantification, Differential Analysis are performed on chemically qualified compound data 31
9 Find by Molecular Feature 19
10 Method Editor MFE 20
11 Method Editor MFE (cont d) 21
12 Method Editor MFE (cont d) Similar compounds (e.g. metabolites) will have similar mass defects, so we can use the Mass Defect tab to filter on that. 22
13 MFE Results 23
14 Find Compounds by Molecular Feature Results Over 280 Compounds Found in Coffee Spiked with Pesticide 24
15 Compound List Use found compounds for further analysis: Use Molecular Formula Generator (MFG) on list. Search a Database and match findings Upload the MFE results to Mass Profiler or GeneSpring MS for analysis. 25
16 Find Compounds by Formula Find Compounds in analysis by inputting: Formulas separated by, CEF file with Formulas A database with Formulas (.csv,.mtl,.cdb) Worklist Formulas 26
17 Find Compounds by Formula - Options Input Formula Source 28
18 Find Compounds by Formula Sample Purity Enables the user to do Sample Purity (not Peak Purity) calculations based on the same algorithms as LC/MS ChemStation Sample Purity compares a peak against all other peaks in the data file to determine the estimated purity of the compound After doing a Find Compounds by Formula, pure compounds are marked green and impure are marked yellow 29
19 Find Compounds by Formula System Suitability Integrate (UV) and Find by Formula Sample Purity It allows the user to calculate system suitability values on a UV chromatogram based on the chosen Pharmacopoeia The results are displayed in the Integration Peak List. 30
20 System Suitability Calculations Can Be Done for MS, MS/MS, UV and GC Chromatograms 31
21 Find Compounds by Formula Results Compounds Found Formulas Found 33
22 Find Compounds by Auto MS/MS Auto MS/MS Data Acquisition function used when the m/z value of the precursor ion is unknown prior to analysis. The instrument acquires a mass spectrum then determines ions meeting preset criteria for precursor ions. MS/MS spectra are taken for each identified precursor. The instrument then switches back to MS operation. Find by Auto MS/MS Data Analysis function used to automatically identify compounds in MS/MS data and create averaged MS and MS/MS spectra for each compound. The functionality is an easy way to mine information from complex data. MS Scan - Precursor Reference Mass Precursor Ion Reference Mass Product Ions MS/MS Scan Product Ions Precursor Ion 34
23 Start with MS/MS Data Very complex data. Difficult to obtain information. Page 35
24 Find by Auto MS/MS Algorithm User-specified excluded ions and persistent background are removed from the Auto MS/MS data file. The remaining spectra are then are divided into groups that represent scans from the same compound. This is done (first for positive ion scans, then for negative ion scans) by finding scans that: Have the same precursor m/z within a user-specified tolerance, and Have retention times within a user-specified window of each other, and Have a TIC value that exceeds a user-specified threshold Best Value is to Find Compounds Based on Product Ion Filters 37
25 Auto MS/MS Parameters Data to be found As of B Can filter results by fragments Appropriate Symmetry for Q-TOF: ppm Exclude Reference Masses 38
26 Find by Auto MS/MS Results MS MS/MS 39
27 Compound List 40
28 Find Compound by Integration New function that is similar to Integrate and Extract Peak Spectra. Results are in the form of Compounds rather than Peaks and User Spectra. 42
29 Find Compound by Integration Best used when compounds are chromatographically separated. Creates Compounds which may be exported as a CEF file. Better labeling after library search than User Spectra: Easer to understand Finds more low level ions 43
30 Find Compound by Integration Integrator and Peak Filter parameter settings are unique to Find Compounds by Integration. 44
31 Find Compound by Integration Exclude Mass(es), Peak Spectrum Extraction, Charge State & Results are shared with other method sections. 45
32 Find Compound by Integration Specify the type of chromatogram to extract & integrate: Will extract the chromatogram even if it is already present. Duplicate TIC when run. Not required to extract the signal in File Open Action. Cannot be used on user defined chromatograms (example EIC). 46
33 Find Compound by Integration Optional - Extract additional chromatogram (not integrated) Optional - Restrict m/z range on BPC 47
34 Find Compound by Integration Adjust Delay Time Will adjust the RT of other signals compared to MS. Applied to GC, TWC, etc. signals when signal is extracted, not after. 48
35 Find Compound by Integration When User Interface Configuration has LC checked the Adjust Delay Time feature is active when extracting signals! 49
36 Find by Targeted MS/MS Algorithm This algorithm extracts a chromatogram for each targeted mass in the data file. This chromatogram is integrated and if the peaks are not eliminated by one of the filters on this tab, a compound is generated. The algorithm uses the targeted masses input in the acquisition method. 50
37 Find by Targeted MS/MS Results 51
38 Find by Targeted MS/MS Can extract MS/MS spectra based on collision energy 52
39 Identify Compounds Search a Database or Library after Find Compounds Generate Formulas after Find Compounds *Sequence editing 53
40 Database Searching Search Mode 54
41 Automated Compound Search METLIN Database 55
42 Accurate Mass Database vs. Library Database: contains an accurate mass, possibly a retention time, and other compound attributes such as CAS ID and the chemical structure for each compound. Accurate Mass Library: contains the same information as a Database plus MS/MS spectra. By convention, Databases are kept in D:\MassHunter\databases and Libraries are kept in D:\MassHunter\Library Libraries from Agilent have the suffix Lib in the name, e.g. SulfasLib.cdb 57
43 Accurate Mass Database vs. Library (cont.) When users search an Accurate Mass Database, they are searching for a specific accurate mass (e.g ) against the accurate masses listed in the Database. When users search a Library, they are searching for a spectrum against the spectra in the Library. Unit Mass Library Search: accessed by turning on the GC Separation Type in the User Interface Configuration dialog box. The Library Editor for Unit Mass Libraries can be accessed by installing Quantitative Analysis. 58
44 Accurate Mass Database Searching If an Accurate Mass Database Search finds a compound, it will place the chemical structure in the Product Ion Spectrum and display the structure in the Structure Viewer pane (must be toggled On). Any links to outside information sources about the compound (e.g. Chemical Abstract Service #, CAS) are active click on them to go to a web site. 59
45 Accurate Mass Library Searching If an Accurate Mass Library Search finds a compound, it will place the chemical structure in the Product Ion Spectrum and display the structure in the Structure Viewer pane (if it is toggled On). Acquired Spectrum It is also possible to display a difference spectrum for the Library hit by toggling the Difference Results button to On in the main toolbar. Library Spectrum Difference Spectrum 60
46 All Ions MS/MS 61
47 Why All Ions MS/MS? -The EU s SANCO compliant screening requires: At least 2 product ions Final confirmation with a reference compound -Fully developed workflow in All Ions MS/MS for compound confirmation and quant method setup. Easy Acquisition method setup Targeted identification of product ions using Agilent s MS/MS libraries Chromatographic confirmation of product ions (coelution score) Rapid Quant method development automatically selects two high quality product ions for each compound, eliminating tedious manual steps -Be prepared for unexpected compounds in the sample -QQQ-like easy acquisition method setup -Productivity tool for faster analysis - Identification and fragment finding done in MH Qualitative Analysis - Routine quantitation and confirmation done in MH Quantitative Analysis 62
48 All Ions MS/MS Targeted Screening Workflow Acquisition PCDL Qual Quant MassHunter Acquisition m/z, ion species Find by Formula on MS low channel High/Low Fragmentor Voltage on TOF and Q-TOF High/Low Collision Energy on Q-TOF Pesticide library 700+ compounds with spectra) Forensics /Tox library (2720 compounds with spectra ) Qual Report Targets Find EICs for fragments on MS high channel Align EICs of fragments with parent EIC Extract Correlate qualified fragments with target Qualify and confirm fragments Export Quantify target with additional fragment ion confirmation Quant Report 63
49 minutes All Ions MS/MS Use and combine PCDL libraries with All Ions MS/MS. Export information and automatically create quant methods in seconds. Reduce processing time from one day to a matter of hours Processing time Quant Qual 0 Without All Ions With Allons 64
50 All Ions MS/MS Setup Turn on All Ions MS/MS using the current Formula Source PCDL Minimum Co-elution score 65
51 All Ions MS/MS can distinguish between isomers Hydrocodone Codeine 66
52 All Ions MS/MS can distinguish between isomers Hydrocodone Codeine 67
53 All Ions MS/MS can distinguish between isomers Hydrocodone Codeine 68
54 All Ions MS/MS: Chromatographic Confirmation of Product Ions Overlaid low and high energy chromatograms Co-elution curves the precursor and product ions agree exactly on their apex! 69
55 New Compound Details View in Qual rev. B New chromatogram and spectrum windows that show data from one compound only. Data belonging to one compound can be overlaid easily and quickly. 70
56 Quality Score for MFE 71
57 Molecular Formula Generator - Calculate Compound Formulas You can generate the molecular formula for each selected compound. First, find the Compounds, then use MFG. Example: Structure Elucidation of Degradation Products of the Antibiotic Drug Amoxicillin HO H H H O COOH O OH COOH HN H NH NH 2 N CH H 2 NH CH 3 O N 3 S NH NH S CH 3 S CH 3 H H H N O H O H O HO HO H COOH CH 3 CH 3 1 Amoxicillin, 2 Amoxicillin penicillinoic acid, 3 Amoxicillin penilloic acid 72
58 Molecular Formula Generator 73
59 Molecular Formula Generator Algorithm Determine a mass in the compound to use for MFG: The program looks at clusters of ions and applies rules for isotopic abundance and mass spacing (mass accuracy and resolution are important to achieve this). Apply user knowledge of samples to limit the possible formula: Users fill out the Allowed Species dialog box with their knowledge of the chemistry of their samples. Rule out formulas that are chemically impossible (e.g. CH 7 ) Calculate probability scores for each candidate formula based on: Calculated vs. measured mass Calculated vs. measured abundance ratios Calculated vs. measured mass intervals of isotopes (isotope spacing) 74
60 Molecular Formula Generator Algorithm (cont.) Rank and display each candidate formula based on its probability score For calculations done in conjunction with MFE, calculate an abundance-weighted average cross score for all species (adducts, dimers, charge states) associated with a compound. These are all listed in the Compound List table 75
61 Molecular Formula Generator Algorithm MS/MS If MS/MS data are available, the algorithm uses it for greater confidence in formula generation: The algorithm generates tentative formulas for each MS/MS fragment (product ion). Precursor formulas with no related product ions are eliminated For a precursor formula to be valid, it must generate product ions that make sense Proposed precursor formulas are scored and ranked based on their fit with the product ions Algorithm uses coverage (explanation of how the precursor fragmented) and mass error of product ions A single score is provided that combines both MS and MS/MS data 76
62 Molecular Formula Generator Algorithm MS/MS Note the scores in the Compound List table below: Score (various) MS Score (MS-only) MS/MS (goodness-of-fit of product ions formulas to precursor formula) As of Qual rev. B.02.00, scores are absolute (Best is not fixed at 100) for comparison across formulae and samples. 77
63 Major Features of Qual B All Ions MS/MS Compound Details View New Quality score for MFE Support for new tmrm files Enhanced Molecular Formula Generation New Find Compound Algorithm : Find by Integration Annotate fragment ions with fragment formula generation Save results faster Export format changes 111
MassHunter Software Overview
MassHunter Software Overview 1 Qualitative Analysis Workflows Workflows in Qualitative Analysis allow the user to only see and work with the areas and dialog boxes they need for their specific tasks A
More informationAll Ions MS/MS: Targeted Screening and Quantitation Using Agilent TOF and Q-TOF LC/MS Systems
All Ions MS/MS: Targeted Screening and Quantitation Using Agilent TOF and Q-TOF LC/MS Systems Technical Overview Introduction All Ions MS/MS is a technique that is available for Agilent high resolution
More informationMaking Sense of Differences in LCMS Data: Integrated Tools
Making Sense of Differences in LCMS Data: Integrated Tools David A. Weil Agilent Technologies MassHunter Overview Page 1 March 2008 How Clean is our Water?... Page 2 Chemical Residue Analysis.... From
More informationAgilent All Ions MS/MS
Agilent All Ions MS/MS Workflow Overview A Determine fragment ions for LC/MS Quant method B Develop final Quant method Develop LC/MS Qualitative Analysis method Process data with Find by Formula Build
More informationAgilent TOF Screening & Impurity Profiling Julie Cichelli, PhD LC/MS Small Molecule Workshop Dec 6, 2012
1 Agilent TOF Screening & Impurity Profiling Julie Cichelli, PhD LC/MS Small Molecule Workshop Dec 6, 2012 Review: Technology for Accurate Mass Analysis: TOF LC/MS Mass measurements accurate to several
More informationDie Nadel im Heuhaufen
Die Nadel im Heuhaufen Workflow zur Identifizierung unerwarteter Komponenten in LC Q-Tof Daten Umwelt & Lebensmittel Seminar Tour Andreas Reimann Produktspezialist LC-MS Agilent Technologies Instrumentation
More informationAn Effective Workflow for Impurity Analysis Incorporating High Quality HRAM LCMS & MSMS with Intelligent Automated Data Mining
An Effective Workflow for Impurity Analysis Incorporating High Quality HRAM LCMS & MSMS with Intelligent Automated Data Mining Dave Weil, Ph.D. and Jim Lau, Ph.D. Typical Method Conditions: 1260 UHPLC
More informationAgilent MassHunter Quantitative Data Analysis
Agilent MassHunter Quantitative Data Analysis Presenters: Howard Sanford Stephen Harnos MassHunter Quantitation: Batch and Method Setup Outliers, Data Review, Reporting 1 MassHunter Quantitative Analysis
More informationAgilent MassHunter Profinder: Solving the Challenge of Isotopologue Extraction for Qualitative Flux Analysis
Agilent MassHunter Profinder: Solving the Challenge of Isotopologue Extraction for Qualitative Flux Analysis Technical Overview Introduction Metabolomics studies measure the relative abundance of metabolites
More informationAgilent MassHunter Quantitative Data Analysis
Agilent MassHunter Quantitative Data Analysis Presenters: Howard Sanford Stephen Harnos MassHunter Quantitation: Batch Table, Compound Information Setup, Calibration Curve and Globals Settings 1 MassHunter
More informationApplication Note. Authors. Abstract. Introduction. Environmental
Using a Chlorine Filter for Accurate-Mass Data Analysis of Environmental Samples Application Note Environmental Authors Imma Ferrer and E. Michael Thurman Center for Environmental Mass Spectrometry University
More informationApplication Note. David A. Weil Zoltan Timar Michael Zumwalt Edgar Naegele. Abstract
Detection and identification of impurities in pharmaceutical drugs Computer-assisted extraction, profiling and analysis of Q-TF data for determination of impurities using Agilent Massunter software Application
More informationTOF/QTOF Users Meeting. Jim Lau, Agilent Technologies.
TOF/QTOF Users Meeting Jim Lau, Agilent Technologies. Agenda Goal Share Best Practices, Develop Network of Agilent Users Today s Topics: Care and Feeding Agilent LCMS Systems Data Acquisition: Optimize
More informationRapid and Accurate Forensics Analysis using High Resolution All Ions MS/MS
Rapid and Accurate Forensics Analysis using High Resolution All Ions MS/MS Application Note Forensic Toxicology Authors Martin Josefsson, and Markus Roman National Board of Forensic Medicine Linköping,
More informationThe new Water Screening PCDL
The new Water Screening PCDL Content and integration in suspect and non-target screening Dr. Thomas Glauner Senior LC/MS Applications Scientist EMEA Market Development Team 1 Accurate mass screening and
More informationExtend Your Metabolomics Insight!
Extend Your Metabolomics Insight! Introducing MassHunter VistaFlux April 2016 Agilent THE Leader in Metabolomics! Fiehn EI Library METLIN MS/MS Library Mass Profiler Professional with Pathway Architect
More informationAnalyzing Compounds of Environmental Interest Using an LC/Q-TOF Part 1: Dyes and Pigments. Application. Introduction. Authors. Abstract.
Analyzing Compounds of Environmental Interest Using an LC/Q-TOF Part 1: Dyes and Pigments Application Environmental Authors Jim Lau, Chin-Kai Meng, and Jennifer Gushue Agilent Technologies, Inc. 285 Centerville
More informationApplication Note. Edgar Naegele. Abstract
Fast identification of main drug metabolites by quadrupole time-of-flight LC/MS Measuring accurate MS and MS/MS data with the Agilent 651 Q-TOF LC/MS and identification of main meta-bolites by comparison
More informationInformation Dependent Acquisition (IDA) 1
Information Dependent Acquisition (IDA) Information Dependent Acquisition (IDA) enables on the fly acquisition of MS/MS spectra during a chromatographic run. Analyst Software IDA is optimized to generate
More informationA Workflow Approach for the Identification and Structural Elucidation of Impurities of Quetiapine Hemifumarate Drug Substance
A Workflow Approach for the Identification and Structural Elucidation of Impurities of Quetiapine Hemifumarate Drug Substance Michael D. Jones, Marian Twohig, Karen Haas, and Robert S. Plumb Waters Corporation,
More informationAgilent 6400 Series Triple Quadrupole LC/MS/MS Users Session
Agilent 6400 Series Triple Quadrupole LC/MS/MS Users Session QQQ Method Development and Optimization MassHunter Quant: Method setup Peak detection optimization Quant troubleshooting David Presser Application
More informationMetabolomics Batch Data Analysis Workflow to Characterize Differential Metabolites in Bacteria
Metabolomics Batch Data Analysis Workflow to Characterize Differential Metabolites in Bacteria Application Note Authors Yuqin Dai and Steven M. Fischer Agilent Technologies, Inc. Santa Clara, CA, USA Abstract
More informationA Q-TOF Generated, Metabolomics- Specifi c LC/MS/MS Library Facilitates Identifi cation of Metabolites in Malaria Infected Erythrocytes
A Q-TOF Generated, Metabolomics- Specifi c LC/MS/MS Library Facilitates Identifi cation of Metabolites in Malaria Infected Erythrocytes Application Note Clinical Research Authors Theodore R. Sana, PhD
More informationWADA Technical Document TD2003IDCR
IDENTIFICATION CRITERIA FOR QUALITATIVE ASSAYS INCORPORATING CHROMATOGRAPHY AND MASS SPECTROMETRY The appropriate analytical characteristics must be documented for a particular assay. The Laboratory must
More informationQuantitation of High Resolution MS Data Using UNIFI: Acquiring and Processing Full Scan or Tof-MRM (Targeted HRMS) Datasets for Quantitative Assays
: Acquiring and Processing Full Scan or Tof-MRM (Targeted HRMS) Datasets for Quantitative Assays Mark Wrona, Jayne Kirk, and Yun Alelyunas Waters Corporation, Milford, MA, USA APPLICATION BENEFITS Ability
More informationCerno Application Note Extending the Limits of Mass Spectrometry
Creation of Accurate Mass Library for NIST Database Search Novel MS calibration has been shown to enable accurate mass and elemental composition determination on quadrupole GC/MS systems for either molecular
More informationTUTORIAL EXERCISES WITH ANSWERS
TUTORIAL EXERCISES WITH ANSWERS Tutorial 1 Settings 1. What is the exact monoisotopic mass difference for peptides carrying a 13 C (and NO additional 15 N) labelled C-terminal lysine residue? a. 6.020129
More informationAgilent ESI and APCI sources: for polar to non-polar compounds
1 Agilent 6400 Series Triple Quadrupole Users Workshop 1 Agilent ESI and APCI sources: for polar to non-polar compounds Nebulizer Pressure Corona current Nebulizer Pressure Vaporizer Vcap Vcap Drying Gas
More informationScreening for Water Pollutants With the Agilent SureTarget GC/MSD Water Pollutants Screener, SureTarget Workflow, and Customized Reporting
Screening for Water Pollutants With the Agilent SureTarget GC/MSD Water Pollutants Screener, SureTarget Workflow, and Customized Reporting Application Note Authors Angela Smith Henry and Bruce Quimby Agilent
More informationKey Words Q Exactive, Accela, MetQuest, Mass Frontier, Drug Discovery
Metabolite Stability Screening and Hotspot Metabolite Identification by Combining High-Resolution, Accurate-Mass Nonselective and Selective Fragmentation Tim Stratton, Caroline Ding, Yingying Huang, Dan
More informationMassHunter METLIN Metabolite PCD/PCDL Quick Start Guide
MassHunter METLIN Metabolite PCD/PCDL Quick Start Guide What is the MassHunter METLIN Metabolite PCD/PCDL? 2 Where to find more information 2 Kit Content 3 Installation 5 Before you start 5 Install MassHunter
More informationUnderstanding Your Spectra Module. Agilent OpenLAB CDS ChemStation Edition
Understanding Your Spectra Module Agilent OpenLAB CDS ChemStation Edition Notices Agilent Technologies, Inc. 1994-2012, 2013 No part of this manual may be reproduced in any form or by any means (including
More informationQTOF Small Molecule Applications Update. April 10 th, David A. Weil. Application Scientist, Schaumburg, IL
QTOF Small Molecule Applications Update April 10 th, 2008 David A. Weil David_weil@agilent.com Application Scientist, Schaumburg, IL December 6 th, 2007 Agenda Goal Share Best Practices, Updates Software/Hardware
More informationMulti-residue analysis of pesticides by GC-HRMS
An Executive Summary Multi-residue analysis of pesticides by GC-HRMS Dr. Hans Mol is senior scientist at RIKILT- Wageningen UR Introduction Regulatory authorities throughout the world set and enforce strict
More informationPesticideScreener. Innovation with Integrity. Comprehensive Pesticide Screening and Quantitation UHR-TOF MS
PesticideScreener Comprehensive Pesticide Screening and Quantitation Innovation with Integrity UHR-TOF MS The Challenge of Comprehensive Pesticide Residue Analysis The use of pesticides to reduce crop
More informationOverview. Introduction. André Schreiber AB SCIEX Concord, Ontario (Canada)
Quantitation and Identification of Pharmaceuticals and Personal Care Products (PPCP) in Environmental Samples using Advanced TripleTOF MS/MS Technology André Schreiber AB SCIEX Concord, Ontario (Canada)
More informationWADA Technical Document TD2015IDCR
MINIMUM CRITERIA FOR CHROMATOGRAPHIC-MASS SPECTROMETRIC CONFIRMATION OF THE IDENTITY OF ANALYTES FOR DOPING CONTROL PURPOSES. The ability of a method to identify an analyte is a function of the entire
More informationSEAMLESS INTEGRATION OF MASS DETECTION INTO THE UV CHROMATOGRAPHIC WORKFLOW
SEAMLESS INTEGRATION OF MASS DETECTION INTO THE UV CHROMATOGRAPHIC WORKFLOW Paula Hong, John Van Antwerp, and Patricia McConville Waters Corporation, Milford, MA, USA Historically UV detection has been
More informationCompounding insights Thermo Scientific Compound Discoverer Software
Compounding insights Thermo Scientific Compound Discoverer Software Integrated, complete, toolset solves small-molecule analysis challenges Thermo Scientific Orbitrap mass spectrometers produce information-rich
More informationLC/Q-TOF Workflows for Comprehensive Micropollutant Analysis
LC/Q-TO Workflows for Comprehensive Micropollutant Analysis Targeted Quantification, Suspect Screening, and Unknown Compound Identification Application Note Environmental Authors Christoph Moschet and
More informationTutorial 2: Analysis of DIA data in Skyline
Tutorial 2: Analysis of DIA data in Skyline In this tutorial we will learn how to use Skyline to perform targeted post-acquisition analysis for peptide and inferred protein detection and quantitation using
More informationAgilent 6400 Series Triple Quadrupole Users Workshop. MH QQQ Users workshop 2/21/2014 1
Agilent 6400 Series Triple Quadrupole Users Workshop 1 Agilent 6400 Series Triple Quadrupole Users Workshop QQQ Method Development and Optimization MassHunter Quantitation: Batch and Method setup QC s,
More informationPharmaceutical Impurity Identification and Profiling Using Agilent Q-TOF LC/MS Combined with Advanced MassHunter Data Processing Software
Pharmaceutical Impurity Identification and Profiling Using Agilent Q-TF LC/MS Combined with Advanced Massunter Data Processing Software Application Note Authors Siji Joseph Agilent Technologies LSCI Bangalore,
More informationCerno Bioscience MassWorks: Acquiring Calibration Data on Agilent GC/MSDs
Cerno Bioscience MassWorks: Acquiring Calibration Data on Agilent GC/MSDs Application Note Author Harry Prest, Ph.D. Senior Chemist in GC-MS Agilent Technologies, Inc. 5301 Stevens Creek Blvd Santa Clara,
More informationHigh-Throughput Protein Quantitation Using Multiple Reaction Monitoring
High-Throughput Protein Quantitation Using Multiple Reaction Monitoring Application Note Authors Ning Tang, Christine Miller, Joe Roark, Norton Kitagawa and Keith Waddell Agilent Technologies, Inc. Santa
More informationBioanalytical Chem: 4590: LC-MSMS of analgesics LC-MS Experiment Liquid Chromatography Mass Spectrometry (LC/MS)
Liquid Chromatography Mass Spectrometry (LC/MS) Prelab Questions: Questions to be answered before doing the experiment. The answers are due at the beginning of each experiment without exception (the questions
More informationApplication Note LCMS-116 What are we eating? MetaboScape Software; Enabling the De-replication and Identification of Unknowns in Food Metabolomics
Application Note LCMS-116 What are we eating? MetaboScape Software; Enabling the De-replication and Identification of Unknowns in Food Metabolomics Introduction Determining the structure of secondary metabolites
More informationProMass Deconvolution User Training. Novatia LLC January, 2013
ProMass Deconvolution User Training Novatia LLC January, 2013 Overview General info about ProMass Features Basics of how ProMass Deconvolution works Example Spectra Manual Deconvolution with ProMass Deconvolution
More informationApplying MRM Spectrum Mode and Library Searching for Enhanced Reporting Confidence in Routine Pesticide Residue Analysis
PO-CON1768E Applying MRM Spectrum Mode and Library Searching for Enhanced Reporting Confidence in Routine Pesticide ASMS 2017 TP-194 David Baker 1, Christopher Titman 1, Neil Loftus 1, Jonathan Horner
More informationA Rapid Approach to the Confirmation of Drug Metabolites in Preclinical and Clinical Bioanalysis Studies
A Rapid Approach to the Confirmation of Drug Metabolites in Preclinical and Clinical Bioanalysis Studies APPLICATION BENEFITS Regulatory guidelines and recommendations place a greater emphasis on the detection
More informationSimplified Approaches to Impurity Identification using Accurate Mass UPLC/MS
Simplified Approaches to Impurity Identification using Accurate Mass UPLC/MS Marian Twohig, Michael D. Jones, Dominic Moore, Peter Lee, and Robert Plumb Waters Corporation, Milford, MA, USA APPLICATION
More informationprofileanalysis Innovation with Integrity Quickly pinpointing and identifying potential biomarkers in Proteomics and Metabolomics research
profileanalysis Quickly pinpointing and identifying potential biomarkers in Proteomics and Metabolomics research Innovation with Integrity Omics Research Biomarker Discovery Made Easy by ProfileAnalysis
More informationTheory and Practical Consequences.
Theory and Practical Consequences. Number of hits depending on reachable mass accuracy 250 hits @ ±10 ppm 137 hits @ ±5 ppm 78 hits @ ±3 ppm 29 hits @ ±1 ppm 3 hits @ ±0.1 ppm 1 hit @ ± 0.05 ppm Intens.
More informationAccelerating the Metabolite Identification Process Using High Resolution Q-TOF Data and Mass-MetaSite Software
Accelerating the Metabolite Identification Process Using High Resolution Q-TOF Data and Mass-MetaSite Software Application ote Drug discovery and development: Metabolite Identifi cation Authors Yuqin Dai,
More informationAgilent Technologies LCMS Portfolio
Agilent Technologies LCMS Portfolio Hardware and Software Solutions for the Most Challenging Applications Jean-Francois Roy MS Product Specialist Agilent Technologies 1 Raising the Standard in UHPLC Highest
More informationThe Agilent 6545 Q-TOF LC/MS System THE ANSWERS YOU NEED: BETTER, FASTER, EASIER
The Agilent 6545 Q-TOF LC/MS System THE ANSWERS YOU NEED: BETTER, FASTER, EASIER THE AGILENT 6545 Q-TOF LC/MS SYSTEM FASTER ANSWERS BETTER MEASUREMENTS EASIER HIGH PERFORMANCE RESULTS The new 6545 Q-TOF
More informationAnalysis of a Verapamil Microsomal Incubation using Metabolite ID and Mass Frontier TM
Application Note: 320 Analysis of a Verapamil Microsomal Incubation using Metabolite ID and Mass Frontier TM Key Words Metabolism Study Structure Elucidation Metabolite ID Mass Frontier Chromatography
More informationIdentifying Disinfection Byproducts in Treated Water
Identifying Disinfection Byproducts in Treated Water Jonathan D. Byer, LEC Corporation; Saint Joseph, Michigan USA Susan D. Richardson, University of South Carolina; Columbia, South Carolina USA 1. Introduction
More informationScreening and Quantitation of 240 Pesticides in Difficult Food Matrixes Using the Agilent 6545 Q-TOF LC/MS System
Screening and Quantitation of 24 Pesticides in Difficult Food Matrixes Using the Agilent 6545 Q-TOF LC/MS System Application Note Authors Dan-Hui Dorothy Yang, Christian Klein, Crystal Cody, and Huy Bui
More informationAnalyst Software. Peptide and Protein Quantitation Tutorial
This document is provided to customers who have purchased AB Sciex equipment to use in the operation of such AB Sciex equipment. This document is copyright protected and any reproduction of this document
More informationUNIFI - Targeted and Untargeted Screening MS Software
UNIFI - Targeted and Untargeted Screening MS Software Dr David Hardy Senior Product Manager Mass Spectrometry Software 2011 Waters Corporation 1 Waters System Solutions - Available with UNIFI Biopharmaceutical
More informationNew Approaches to the Development of GC/MS Selected Ion Monitoring Acquisition and Quantitation Methods Technique/Technology
New Approaches to the Development of GC/MS Selected Ion Monitoring Acquisition and Quantitation Methods Technique/Technology Gas Chromatography/Mass Spectrometry Author Harry Prest 1601 California Avenue
More informationMetWorks Metabolite Identification Software
m a s s s p e c t r o m e t r y MetWorks Metabolite Identification Software Enabling Confident Analysis of Metabolism Data Part of Thermo Fisher Scientific MetWorks Software for the Confident Analysis
More informationWorkflow Using Hyphenated Mass Spectrometry Techniques
Pesticide Analysis Workflow Using Hyphenated Mass Spectrometry Techniques Chinkai (Kai) Meng, Ph.D. Senior Applications Chemist Wilmington, Delaware USA chin_meng@agilent.com com February 12, 2009 Page
More informationTargetScreener. Innovation with Integrity. A Comprehensive Screening Solution for Forensic Toxicology UHR-TOF MS
TargetScreener A Comprehensive Screening Solution for Forensic Toxicology Innovation with Integrity UHR-TOF MS TargetScreener Get the Complete Picture Forensic laboratories are frequently required to perform
More informationProtein Deconvolution Version 2.0
Thermo Protein Deconvolution Version 2.0 User Guide XCALI-97414 Revision A August 2012 2012 Thermo Fisher Scientific Inc. All rights reserved. ReSpect is a trademark of Positive Probability Ltd. Xcalibur
More informationWelcome! Course 7: Concepts for LC-MS
Welcome! Mass Spectrometry meets Cheminformatics Tobias Kind and Julie Leary UC Davis Course 7: Concepts for LC-MS Class website: CHE 241 - Spring 28 - CRN 16583 Slides: http://fiehnlab.ucdavis.edu/staff/kind/teaching/
More informationComputer-assisted analysis of complex natural product extracts
Computer-assisted analysis of complex natural product extracts Detection of known and identification of unknown compounds from Q-TF mass spectrometry with the Agilent MassHunter Metabolite ID software
More informationUsing the ACD/MS Manager Software with Agilent 1100 Series LC/MS Systems. Application Note
Using the ACD/MS Manager Software with Agilent 1100 Series LC/MS Systems Application Note Bryan Miller, Christine Miller, Paul Goodley, Masahiko Takino Introduction ACD/MS Manager software from Advanced
More informationSRM assay generation and data analysis in Skyline
in Skyline Preparation 1. Download the example data from www.srmcourse.ch/eupa.html (3 raw files, 1 csv file, 1 sptxt file). 2. The number formats of your computer have to be set to English (United States).
More informationAgilent Technologies at TIAFT 2013
Agilent Technologies at TIAFT 2013 Agilent Technologies GC/MS portfolio for the growing challenge of designer drugs analysis Juan Aybar Gas Chromatography Marketing Jaume Morales MS Product Specialist
More informationCerno Application Note Extending the Limits of Mass Spectrometry
Confident Compound Identification with High Mass Accuracy and Elemental Composition Specific NIST Library Search Identification of unknown compounds by unit mass resolution GC-MS systems essentially relies
More informationAutomated and accurate component detection using reference mass spectra
TECHNICAL NOTE 72703 Automated and accurate component detection using reference mass spectra Authors Barbara van Cann 1 and Amit Gujar 2 1 Thermo Fisher Scientific, Breda, NL 2 Thermo Fisher Scientific,
More informationFORENSIC TOXICOLOGY SCREENING APPLICATION SOLUTION
FORENSIC TOXICOLOGY SCREENING APPLICATION SOLUTION A purpose-built collection of the best-inclass components for forensic toxicology Whether you re challenged to present reliable and secure forensic sample
More informationAgilent G3212 GC-APCI Source
Agilent G3212 GC-APCI Source Quick Start Guide Where to find information 2 Getting Started 3 Step 1. Start the Data Acquisition program for the GC and the Q-TOF 3 Step 2. Prepare the GC and Q-TOF for data
More informationRapid Pesticide Screening and Identification Using the High Resolution All Ions MS/MS Technique
Rapid Pesticide Screening and Identification Using the High Resolution All Ions MS/MS Technique Application Note Food Safety Authors Bernhard Wüst and Thomas Glauner Agilent Technologies GmbH Waldbronn
More informationLC-MS. Pre-processing (xcms) W4M Core Team. 22/09/2015 v 1.0.0
LC-MS Pre-processing (xcms) W4M Core Team 22/09/2015 v 1.0.0 Acquisition files pre-processing with xcms: extraction, alignment and retention time drift correction. SECTION 1 2 Extraction with XCMS R based
More informationTutorial 1: Setting up your Skyline document
Tutorial 1: Setting up your Skyline document Caution! For using Skyline the number formats of your computer have to be set to English (United States). Open the Control Panel Clock, Language, and Region
More informationLC walk-up system using the Agilent 1200 Series LC Method Development Solution and Agilent Easy Access software. Application Note
LC walk-up system using the Agilent 12 Series LC Method Development Solution and Agilent Easy Access software Test of reaction kinetics, column scouting, and impurity checks with one LC system and up to
More informationSUSPECT AND NON-TARGET SCREENING OF ORGANIC MICROPOLLUTANTS IN WASTEWATER THROUGH THE DEVELOPMENT OF A LC-HRMS BASED WORKFLOW
SUSPECT AND NON-TARGET SCREENING OF ORGANIC MICROPOLLUTANTS IN WASTEWATER THROUGH THE DEVELOPMENT OF A LC-HRMS BASED WORKFLOW Pablo Gago-Ferrero Laboratory of Analytical Chemistry Department of Chemistry
More informationThe 5975 inert MSD Benefits of Enhancements in Chemical Ionization Operation Technical Note
The 5975 inert MSD Benefits of Enhancements in Chemical Ionization Operation Technical Note Authors Chris Sandy Agilent Technologies Wokingham, Berkshire, UK Jean-Francois Garnier Agilent Technologies
More informationProtein Quantitation II: Multiple Reaction Monitoring. Kelly Ruggles New York University
Protein Quantitation II: Multiple Reaction Monitoring Kelly Ruggles kelly@fenyolab.org New York University Traditional Affinity-based proteomics Use antibodies to quantify proteins Western Blot RPPA Immunohistochemistry
More information1. Prepare the MALDI sample plate by spotting an angiotensin standard and the test sample(s).
Analysis of a Peptide Sequence from a Proteolytic Digest by MALDI-TOF Post-Source Decay (PSD) and Collision-Induced Dissociation (CID) Standard Operating Procedure Purpose: The following procedure may
More informationCharacterization and Classification of Heroin from Illicit Drug Seizures Using the Agilent 7200 GC/Q-TOF
Characterization and Classification of Heroin from Illicit Drug Seizures Using the Agilent 72 GC/Q-TOF Application Note Forensics Authors Koluntaev Dmitry InterLab Inc. Moscow, Russia Sergei Syromyatnikov
More informationQ-TOF PREMIER DYNAMIC RANGE ENHANCEMENT AND ACCURATE MASS MEASUREMENT PERFORMANCE
Q-TOF PREMIER DYAMIC RAGE EHACEMET AD ACCURATE MASS MEASUREMET PERFORMACE Michael McCullagh, Jose Castro-Perez, and Lisa Calton Waters Corporation, Manchester, UK ITRODUCTIO The use of time-of-flight (TOF)
More informationWhat s New in NIST11 (April 3, 2011)
What s New in NIST11 (April 3, 2011) NIST11 consists of the 2011 release of the NIST/EPA/NIH Electron Ionization (EI) Mass Spectral Database, the NIST MS/MS Database, and the NIST GC Methods and Retention
More informationDe Novo Metabolite Chemical Structure Determination. Paul R. West Ph.D. Stemina Biomarker Discovery, Inc.
De Novo Metabolite Chemical Structure Determination Paul R. West Ph.D. Stemina Biomarker Discovery, Inc. As a part of non targeted metabolomic analysis, when peaks in the mass spectra are thought to be
More informationApplication Note. Edgar Naegele. Abstract
Agilent MassHunter Fast computer aided analysis of LC/ESI-TF data from complex natural product extracts Part 1: Analysis of Agilent 6210 TF data with the Molecular Feature Extractor in MassHunter Workstation
More informationStructural Analysis by In-Depth Impurity Search Using MetID Solution and High Accuracy MS/MS
C146-E118 Structural Analysis by In-Depth Impurity Search Using MetID Solution and High Accuracy MS/MS Technical Report vol.16 1. Introduction MetID Solution is a software application that was developed
More informationGAS CHROMATOGRAPHY MASS SPECTROMETRY. Pre-Lab Questions
GAS CHROMATOGRAPHY MASS SPECTROMETRY Pre-Lab Questions Questions to be answered before doing the experiment. The answers are due at the beginning of each experiment without exception (the questions are
More informationIdentification and Quantitation of Pesticides in Chamomile and Ginger Extracts Using an Agilent 6460 Triple Quadrupole LC/MS system with Triggered MRM
Identification and Quantitation of Pesticides in Chamomile and Ginger Extracts Using an Agilent 646 Triple Quadrupole LC/MS system with Triggered MRM Application Note Authors Thomas Glauner Agilent Technologies,
More informationAB SCIEX SelexION Technology Used to Improve Mass Spectral Library Searching Scores by Removal of Isobaric Interferences
AB SCIEX SelexION Technology Used to Improve Mass Spectral Library Searching s by Removal of Isobaric Interferences Differential Mobility Used as a Tool to Address Selectivity Challenges Adrian M. Taylor
More informationWALKUP LC/MS FOR PHARMACEUTICAL R&D
Pharmaceutical Workflow Solutions WALKUP LC/MS FOR PHARMACEUTICAL R&D Chemists, Peptide/Protein Chemists, Biologists, and Beyond MASSHUNTER WALKUP A Single User Interface for Robust and Reliable LC/MS
More informationAgilent METLIN Personal Metabolite Database and Library MORE CONFIDENCE IN COMPOUND IDENTIFICATION
Agilent METLIN Personal Metabolite Database and Library MORE CONFIDENCE IN COMPOUND IDENTIFICATION COMPOUND IDENTIFICATION AT YOUR FINGERTIPS Compound identifi cation is a key element in untargeted metabolomics
More informationBuilding Inflation Tables and CER Libraries
Building Inflation Tables and CER Libraries January 2007 Presented by James K. Johnson Tecolote Research, Inc. Copyright Tecolote Research, Inc. September 2006 Abstract Building Inflation Tables and CER
More informationApplication Note 12: Fully Automated Compound Screening and Verification Using Spinsolve and MestReNova
Application Note : Fully Automated Compound Screening and Verification Using Spinsolve and MestReNova Paul Bowyer, Magritek, Inc. and Mark Dixon, Mestrelab Sample screening to verify the identity or integrity
More informationNew Dynamic MRM Mode Improves Data Quality and Triple Quad Quantification in Complex Analyses
New Dynamic MRM Mode Improves Data Quality and Triple Quad Quantification in Complex Analyses Technical Overview Authors Abstract Peter Stone, Thomas Glauner, Frank Kuhlmann, Tim Schlabach and Ken Miller
More informationPerforming Peptide Bioanalysis Using High Resolution Mass Spectrometry with Target Enhancement MRM Acquisition
Performing Peptide Bioanalysis Using High Resolution Mass Spectrometry with Target Enhancement MRM Acquisition Yun Wang Alelyunas, Mark D. Wrona, and Nick Tomczyk Waters Corporation, Milford, MA, USA GOAL
More informationOECD QSAR Toolbox v.4.1. Tutorial illustrating new options for grouping with metabolism
OECD QSAR Toolbox v.4.1 Tutorial illustrating new options for grouping with metabolism Outlook Background Objectives Specific Aims The exercise Workflow 2 Background Grouping with metabolism is a procedure
More informationThermo Scientific Pesticide Explorer Collection. Start-to-finish. workflows for pesticide analysis
Thermo Scientific Pesticide Explorer Collection Start-to-finish workflows for pesticide analysis Comprehensive Pesticide Analysis Solutions Pesticide Explorer Collection Selection table Lab Profile Routine
More information