1 Stuff That Is Not Particularly Useful But Studied and Researched to Death Joseph Lstiburek, Ph.D., P.Eng, ASHRAE Fellow Building Science Adventures In Building Science Stuff That Is Very Useful but Ignored by the Research Community presented by Joseph Lstiburek 2 Stuff That Is Not Particularly Useful But Studied and Researched to Death this is called Physics Stuff That Is Very Useful but Ignored by the Research Community this is called Engineering Flow Through Orifices Turbulent Flow - inertial effects Flow Through Porous Media Laminar Flow - viscosity effects Joseph Lstiburek 3 Joseph Lstiburek 4 Lstiburek buildingscience.com 1 of 20

2 Flow Through Orifices Turbulent Flow - inertial effects Flow Through Porous Media Laminar Flow - viscosity effects Q = A C D ( P ) Q = C K ( P ) Bernoulli Darcy true but not useful Joseph Lstiburek 5 Joseph Lstiburek Q = A C D ( P ) Bernoulli Q = A C D ( P ) Bernoulli Q = C K ( P ) Darcy Q = C K ( P ) Darcy Q = A C( P) 1 2 Q = C( P) Q = A C( P) 1 2 Q = C( P) Q = A C( P) n Kronval an engineer Joseph Lstiburek 7 Joseph Lstiburek 8 Lstiburek buildingscience.com 2 of 20

3 The Cult of The Blower Door Joseph Lstiburek 9 Joseph Lstiburek 10 Joseph Lstiburek 11 Joseph Lstiburek 12 Lstiburek buildingscience.com 3 of 20

4 Cost of Addressing the Problems Are Less Than The Cost of Testing To See If You Have Problems Cost of Addressing the Problems Are Less Than The Cost of Testing To See If You Have Problems Nike Approach - Just Do It Joseph Lstiburek 13 Joseph Lstiburek 14 Don t Do Stupid Things Combustion Safety Indoor Contaminants Comfort Energy Joseph Lstiburek 15 Joseph Lstiburek 16 Lstiburek buildingscience.com 4 of 20

5 Bring Combustion Appliances Up To Code Control Pressures Install Controlled Ventilation Get Rid of Big Holes Insulate Joseph Lstiburek 17 Joseph Lstiburek 18 Joseph Lstiburek 19 Joseph Lstiburek 20 Lstiburek buildingscience.com 5 of 20

6 Joseph Lstiburek 21 Joseph Lstiburek 22 Joseph Lstiburek 23 Joseph Lstiburek 24 Lstiburek buildingscience.com 6 of 20

7 Joseph Lstiburek 25 Joseph Lstiburek 26 Joseph Lstiburek 27 Joseph Lstiburek 28 Lstiburek buildingscience.com 7 of 20

8 Joseph Lstiburek 29 Joseph Lstiburek 30 Code Compliant Combustion Air Joseph Lstiburek 31 Joseph Lstiburek 32 Lstiburek buildingscience.com 8 of 20

9 Joseph Lstiburek 33 Joseph Lstiburek 34 Joseph Lstiburek 35 Joseph Lstiburek 36 Lstiburek buildingscience.com 9 of 20

10 Joseph Lstiburek 37 Joseph Lstiburek 38 Joseph Lstiburek 39 Joseph Lstiburek 40 Lstiburek buildingscience.com 10 of 20

11 Sealed Combustion Appliances Joseph Lstiburek 41 Joseph Lstiburek 42 Joseph Lstiburek 43 Joseph Lstiburek 44 Lstiburek buildingscience.com 11 of 20

12 Joseph Lstiburek 45 Joseph Lstiburek 46 Control Pressures Joseph Lstiburek 47 Joseph Lstiburek 48 Lstiburek buildingscience.com 12 of 20

13 Joseph Lstiburek 49 Joseph Lstiburek 50 Joseph Lstiburek 51 Joseph Lstiburek 52 Lstiburek buildingscience.com 13 of 20

14 Joseph Lstiburek 53 Joseph Lstiburek 54 Joseph Lstiburek 55 Joseph Lstiburek 56 Lstiburek buildingscience.com 14 of 20

15 Joseph Lstiburek 57 Joseph Lstiburek 58 Joseph Lstiburek 59 Joseph Lstiburek 60 Lstiburek buildingscience.com 15 of 20

16 Joseph Lstiburek 61 Joseph Lstiburek 62 Joseph Lstiburek 63 Joseph Lstiburek 64 Lstiburek buildingscience.com 16 of 20

17 Joseph Lstiburek 65 Joseph Lstiburek 66 Joseph Lstiburek 67 Joseph Lstiburek 68 Lstiburek buildingscience.com 17 of 20

18 Controlled Ventilation Joseph Lstiburek 69 Joseph Lstiburek 70 Three Types of Controlled Ventilation Systems Exhaust Ventilation Supply Ventilation Balanced Ventilation Joseph Lstiburek 71 Joseph Lstiburek 72 Lstiburek buildingscience.com 18 of 20

19 Joseph Lstiburek 73 Joseph Lstiburek 74 Joseph Lstiburek 75 Joseph Lstiburek 76 Lstiburek buildingscience.com 19 of 20

20 Joseph Lstiburek 77 Joseph Lstiburek 78 ASHRAE Standard 62.2 calls for 7.5 cfm per person plus 0.01 cfm per square foot of conditioned area Occupancy is deemed to be the number of bedrooms plus one Occupant Rate + Building Rate Joseph Lstiburek 79 Lstiburek buildingscience.com 20 of 20

Renovation and Rehabilitation Part I June 2, Joseph Lstiburek, Ph.D., P.Eng, ASHRAE Fellow. Adventures In Building Science

Renovation and Rehabilitation Part I June 2, Joseph Lstiburek, Ph.D., P.Eng, ASHRAE Fellow. Adventures In Building Science Joseph Lstiburek, Ph.D., P.Eng, ASHRAE Fellow Building Science Adventures In Building Science www.buildingscience.com What is a Building? Joseph Lstiburek 2 Lstiburek buildingscience.com 1 of 38 A Building

More information

Building Envelope Council Adventures in Building Science October 17, Don t Do Stupid Things It s Harder When You Are Stupid

Building Envelope Council Adventures in Building Science October 17, Don t Do Stupid Things It s Harder When You Are Stupid Life is Tough Enough As it Is Joseph Lstiburek, Ph.D., P.Eng, ASHRAE Fellow Adventures In www.buildingscience.com Joseph Lstiburek 2 Life is Tough Enough As it Is Don t Do Stupid Things It s Harder When

More information

A Calibrated Multi-Zone Airflow Model for Extension of Ventilation System Tracer Gas Testing

A Calibrated Multi-Zone Airflow Model for Extension of Ventilation System Tracer Gas Testing building science.com 2009 Building Science Press All rights of reproduction in any form reserved. A Calibrated Multi-Zone Airflow Model for Extension of Ventilation System Tracer Gas Testing Conference

More information

CHARACTERISATION OF PRESSURE AND VELOCITY OF AIR FLOW THROUGH PERFORATED PIPE: EXPERIMENTAL AND COMPUTATIONAL APPROACH

CHARACTERISATION OF PRESSURE AND VELOCITY OF AIR FLOW THROUGH PERFORATED PIPE: EXPERIMENTAL AND COMPUTATIONAL APPROACH CHARACTERISATION OF PRESSURE AND VELOCITY OF AIR FLOW THROUGH PERFORATED PIPE: EXPERIMENTAL AND COMPUTATIONAL APPROACH *Helmisyah Ahmad Jalaludin, 2 Mohd Daniel Bakri Omar, 2 Ow Chee Seng *Faculty of Mechanical

More information

Building Science. Some Interesting Stuff on Slabs. Water Flow Through Slab. Mechanisms of Flow. buildingscience.com 9/25/09

Building Science. Some Interesting Stuff on Slabs. Water Flow Through Slab. Mechanisms of Flow. buildingscience.com 9/25/09 Water Flow Through Slab Joseph Lstiburek, Ph.D., P.Eng Building Science Some Interesting Stuff on Slabs From under the slab From the edge of the slab From the slab itself presented by www.buildingscience.com

More information

CALCULATION OF DISCHARGE COEFFICIENT IN COMPLEX OPENING (LAMINAR FLOW)

CALCULATION OF DISCHARGE COEFFICIENT IN COMPLEX OPENING (LAMINAR FLOW) CALCULATION OF DISCHARGE COEFFICIENT IN COMPLEX OPENING (LAMINAR FLOW) Teerapong Boonterm 1, Prapun Tuntayapirom 1 Chirdpun Vitooraporn *1 1 Department of Mechanical Engineering Faculty of Engineering

More information

Air Diffusion Designing for Comfort

Air Diffusion Designing for Comfort Air Diffusion Designing for Comfort Occupant Comfort Air Diffusion Selection ADPI Air Diffusion Performance index Ventilation Effectiveness Induction Room Space Induction Design Criteria ISO7730 ASHRAE

More information

Proceedings of CLIMA 2000 World Congress, Brussels, Belgium. Simplified Method for Indoor Airflow Simulation

Proceedings of CLIMA 2000 World Congress, Brussels, Belgium. Simplified Method for Indoor Airflow Simulation Proceedings of CLIMA 2000 World Congress, Brussels, Belgium. Simplified Method for Indoor Airflow Simulation Qingyan Chen and Weiran Xu Building Technology Program, Department of Architecture Massachusetts

More information

2 nd Joint Summer School on Fuel Cell and Hydrogen Technology September 2012, Crete, Greece. Hydrogen fires

2 nd Joint Summer School on Fuel Cell and Hydrogen Technology September 2012, Crete, Greece. Hydrogen fires 2 nd Joint Summer School on Fuel Cell and Hydrogen Technology 17 28 September 2012, Crete, Greece Hydrogen fires Sile Brennan (on behalf of the HySAFER group) Hydrogen Safety Engineering and Research Centre

More information

PARTS MANUAL Gas Furnace F9MAC, G9MAC

PARTS MANUAL Gas Furnace F9MAC, G9MAC Gas Furnace F9MAC, G9MAC Safety Labeling and Signal Words DANGER, WARNING, CAUTION, and NOTE The signal words DANGER, WARNING, CAUTION, and NOTE are used to identify levels of hazard seriousness. The signal

More information

COMMERCIAL HEAT GAIN - HEAT LOSS CALCULATION LOAD FORM

COMMERCIAL HEAT GAIN - HEAT LOSS CALCULATION LOAD FORM COMMERCIAL HEAT GAIN - HEAT LOSS CALCULATION LOAD FORM Job Name: Address: Phone/Fax/Email: Contractor: Address: Phone/Fax/Email: Heat Gain Summary Sensible Heat (Btu/h) Latent Heat (Btu/h) Total Heat Gain

More information

Insight It s All Relative

Insight It s All Relative Insight Magic and Mystery of the Water Molecule An edited version of this Insight first appeared in the ASHRAE Journal. By Joseph W. Lstiburek, Ph.D., P.Eng., Fellow ASHRAE It is just shocking, just shocking

More information

Chemical Storage Guide

Chemical Storage Guide 1 P a g e Chemical Storage Guide It is the responsibility of every occupant, owner, tenant, contractor, employee & visitor and ALL users of this facility to ensure they take all reasonably practical steps

More information

This report shows the capabilities of Tdyn for modelling the fluid flow through porous media.

This report shows the capabilities of Tdyn for modelling the fluid flow through porous media. Flow through porous media 1 Flow through porous media Introduction This report shows the capabilities of Tdyn for modelling the fluid flow through porous media. Modelling approach Modeling of flows through

More information

GMVC8. ComfortNet -Compatible. Heating Input: 70, ,000 BTU/h. Two-Stage, Variable-Speed Gas Furnace

GMVC8. ComfortNet -Compatible. Heating Input: 70, ,000 BTU/h. Two-Stage, Variable-Speed Gas Furnace 80% AFUE Heating Input: 70,000 115,000 BTU/h ComfortNet -Compatible Two-Stage, Variable-Speed Gas Furnace Standard Features Aluminized steel, dual-diameter tubular heat exchanger Two-stage gas valve operates

More information

FLUID FLOW FOR THE PRACTICING CHEMICAL ENGINEER

FLUID FLOW FOR THE PRACTICING CHEMICAL ENGINEER FLUID FLOW FOR THE PRACTICING CHEMICAL ENGINEER J. Patrick Abulencia Louis Theodore WILEY A JOHN WILEY & SONS, INC., PUBLICATION PREFACE INTRODUCTION xvii xix I INTRODUCTION TO FLUID FLOW 1 II History

More information

Today s A/C systems include:

Today s A/C systems include: * www.sgvenergywise.org Replac ing your A/C system REQUIRES a permit from your c ity - it s important. WHY? Because A/C (air conditioning) is a SYSTEM, not just one piece of equipment. The thermostat,

More information

APPLIED FLUID DYNAMICS HANDBOOK

APPLIED FLUID DYNAMICS HANDBOOK APPLIED FLUID DYNAMICS HANDBOOK ROBERT D. BLEVINS H imhnisdia ttodisdiule Darmstadt Fachbereich Mechanik 'rw.-nr.. [VNR1 VAN NOSTRAND REINHOLD COMPANY ' ' New York Contents Preface / v 1. Definitions /

More information

Welcome. HVAC Change Out Regulations and Rater Verification California Track

Welcome. HVAC Change Out Regulations and Rater Verification California Track Welcome HVAC Change Out Regulations and Rater Verification -------------------------------- California Track Douglas Beaman Douglas Beaman Associates 612 13 th Street Modesto, CA 95354 (209) 524-1000 Doug@DougBeaman.com

More information

FOULING OF HVAC FIN AND TUBE HEAT EXCHANGERS

FOULING OF HVAC FIN AND TUBE HEAT EXCHANGERS FOULING OF HVAC FIN AND TUBE HEAT EXCHANGERS Jeffrey Siegel 1 and Van P. Carey 2 1 Lawrence Berkeley National Laboratory, Berkeley, CA 947, USA; E-mail: JASiegel@lbl.gov 2 University of California, Berkeley,

More information

PARTS MANUAL Gas Furnace F8MXN, F8MXL, G8MXN, G8MXL

PARTS MANUAL Gas Furnace F8MXN, F8MXL, G8MXN, G8MXL Gas Furnace F8MXN, F8MXL, G8MXN, G8MXL DANGER, WARNING, CAUTION, and NOTE The signal words DANGER, WARNING, CAU- TION, and NOTE are used to identify levels of hazard seriousness. The signal word DANGER

More information

OPERATIVE TEMPERATURE SIMULATION OF ENCLOSED SPACE WITH INFRARED RADIATION SOURCE AS A SECONDARY HEATER

OPERATIVE TEMPERATURE SIMULATION OF ENCLOSED SPACE WITH INFRARED RADIATION SOURCE AS A SECONDARY HEATER OPERATIVE TEMPERATURE SIMULATION OF ENCLOSED SPACE WITH INFRARED RADIATION SOURCE AS A SECONDARY HEATER L. Hach 1, K. Hemzal 2, Y. Katoh 3 1 Institute of Applied Physics and Mathematics, Faculty of Chemical

More information

Theory & Applications of Computational Fluid Dynamics CFD

Theory & Applications of Computational Fluid Dynamics CFD جمعية رواد الھندسة والتكنولوجيا Theory & Applications of Computational Fluid Dynamics CFD Prepared and Presented By: Hesham Sami Abdul Munem Mechanical Engineer Pressure Vessels Department ENPPI Contents:

More information

Influence of Heat Transfer Process in Porous Media with Air Cavity- A CFD Analysis

Influence of Heat Transfer Process in Porous Media with Air Cavity- A CFD Analysis Proceedings of the 4 th International Conference of Fluid Flow, Heat and Mass Transfer (FFHMT'17) Toronto, Canada August 21 23, 2017 Paper No. 161 DOI: 10.11159/ffhmt17.161 Influence of Heat Transfer Process

More information

Heat Transfer and Natural Ventilation Airflow Rates from Single-sided Heated Solar Chimney for Buildings

Heat Transfer and Natural Ventilation Airflow Rates from Single-sided Heated Solar Chimney for Buildings Heat Transfer and Natural Ventilation Airflow Rates from Single-sided Heated Solar Chimney for Buildings Angui Li* 1, Phillip Jones 2, Pingge Zhao 3 and Liping Wang 3 1 Professor, Department of Environmental

More information

Study of air curtains used to restrict infiltration into refrigerated rooms

Study of air curtains used to restrict infiltration into refrigerated rooms Study of air curtains used to restrict infiltration into refrigerated rooms Gregory Verhaeghe 1, Marnix Van Belleghem 1, Arnout Willockx 1, Ivan Verhaert 1, Michel De Paepe 1 1 Ghent University, Department

More information

An Introduction to Air Pollution

An Introduction to Air Pollution An Introduction to Air Pollution Chapter 6. Fabric filters 薛人瑋 Ph.D 2 nd October 2012 Fabric Filters Fabric filtration Air or combustion gases pass through a fabric Dust is trapped on the fabric Cleaned

More information

Storing, using and disposing of unsealed radioactive substances in a Type C Laboratory: Extract of regulatory requirements

Storing, using and disposing of unsealed radioactive substances in a Type C Laboratory: Extract of regulatory requirements Storing, using disposing of unsealed radioactive substances in a Type C Laboratory: Extract of regulatory requirements Radiation Protection Control (Ionising Radiation) Regulations 2000 Requirements for

More information

(Refer Slide Time: 00:01:19 min)

(Refer Slide Time: 00:01:19 min) Refrigeration and Air Conditioning Prof. M. Ramgopal Department of Mechanical Engineering Indian Institute of Technology, Kharagpur Lecture No. # 40 Cooling and heating Load Calculations Welcome back,

More information

10-year industry best core warranty. 2-year warranty on balance of unit.

10-year industry best core warranty. 2-year warranty on balance of unit. MODEL FEATURES MERV-8 filters Fully insulated case Large cores for high efficiency No condensate pan or drain required AHRI Certified Rainhood included Access door for easy maintenance and Cleaning Integral

More information

Technical Reference Note

Technical Reference Note Technical Reference Note Air Conditioning Contractors of America, s2800 Shirlington Road, Suite Suite 300, 300Arlington, s VA, VA 22206, 22206 703-575-4477, s7035754477 Fax sfax 703-575-4449 7035754449

More information

Study on Stack Effect of Stairwell by Numerical Model of Leakage Flow through Gap of Door

Study on Stack Effect of Stairwell by Numerical Model of Leakage Flow through Gap of Door Open Journal of Fluid Dynamics, 13, 3, 41-47 Published Online December 13 (http://www.scirp.org/journal/ojfd) http://dx.doi.org/1.436/ojfd.13.349 Study on Stack Effect of Stairwell by Numerical Model of

More information

LECTURE 6- ENERGY LOSSES IN HYDRAULIC SYSTEMS SELF EVALUATION QUESTIONS AND ANSWERS

LECTURE 6- ENERGY LOSSES IN HYDRAULIC SYSTEMS SELF EVALUATION QUESTIONS AND ANSWERS LECTURE 6- ENERGY LOSSES IN HYDRAULIC SYSTEMS SELF EVALUATION QUESTIONS AND ANSWERS 1. What is the head loss ( in units of bars) across a 30mm wide open gate valve when oil ( SG=0.9) flow through at a

More information

This is the published version of a paper presented at Healthy Buildings 2017 Europe, Lublin, Poland.

This is the published version of a paper presented at Healthy Buildings 2017 Europe, Lublin, Poland. http://www.diva-portal.org This is the published version of a paper presented at Healthy Buildings 2017 Europe, Lublin, Poland. Citation for the original published paper: Kabanshi, A., Sattari, A., Linden,

More information

Self-Directed Course: Transitional Math Module 4: Algebra

Self-Directed Course: Transitional Math Module 4: Algebra Lesson #1: Solving for the Unknown with no Coefficients During this unit, we will be dealing with several terms: Variable a letter that is used to represent an unknown number Coefficient a number placed

More information

EXPERIMENTAL STUDY OF THE DISCHARGE COEFFICIENT

EXPERIMENTAL STUDY OF THE DISCHARGE COEFFICIENT The Seventh Asia-Pacific onference on Wind Engineering, November 8-1, 009, Taipei, Taiwan EXPERIMENTAL STUDY OF THE DISHARGE OEFFIIENT OF INTERNAL OPENINGS IN PARTITIONED BUILDINGS hia R. hu 1 and Yu-Wen

More information

HOT /05/2014. Page 1 of 14 GENERAL HOUSE CHARACTERISTICS. Natural Resources CANADA Version sample house report

HOT /05/2014. Page 1 of 14 GENERAL HOUSE CHARACTERISTICS. Natural Resources CANADA Version sample house report Page 1 of 14 File: Application Type: sample house report EnerGuide for New Houses HOT2000 Natural Resources CANADA Version 10.51 Weather Library: C:\H2KEGH~1\Dat\Wth100.dir Weather Data for VANCOUVER,

More information

ME411 Engineering Measurement & Instrumentation. Winter 2017 Lecture 11

ME411 Engineering Measurement & Instrumentation. Winter 2017 Lecture 11 ME411 Engineering Measurement & Instrumentation Winter 2017 Lecture 11 1 Flow Measurement Identify an effect that depends on flow rate Process control requires accurate measurement of flow control Mixing

More information

STUDENT MODELLING COMPETITION

STUDENT MODELLING COMPETITION STUDENT MODELLING COMPETITION Design and simulation of an energy-positive house Building Simulation 2013 Briefing Document L. Stephan T.Béjat O. Flechon M. J. Cook Version 1.1 Presentation of the competition

More information

Ceiling Radiant Cooling Panels Employing Heat-Conducting Rails: Deriving the Governing Heat Transfer Equations

Ceiling Radiant Cooling Panels Employing Heat-Conducting Rails: Deriving the Governing Heat Transfer Equations Authors may request permission to reprint or post on their personal or company Web site once the final version of the article has been published. A reprint permission form may be found at www.ashrae.org.

More information

Thermal Fluid System Design. Team Design #1

Thermal Fluid System Design. Team Design #1 Thermal Fluid System Design Team Design #1 Table of Contents Nomenclature Listing.3 Executive Summary.6 Introduction.7 Analysis.8 Results/Discussion..18 Conclusion..29 References..29 Appendix A: Detailed

More information

Introduction to Chemical Engineering Computing, 2 nd edition, Bruce A. Finlayson, Wiley (2012)

Introduction to Chemical Engineering Computing, 2 nd edition, Bruce A. Finlayson, Wiley (2012) Introduction to Chemical Engineering Computing, 2 nd edition, Bruce A. Finlayson, Wiley (2012) The following web sites can be used to obtain material from Wiley. It includes the keys to the problems (useful

More information

CONVECTION HEAT TRANSFER

CONVECTION HEAT TRANSFER CONVECTION HEAT TRANSFER THIRD EDITION Adrian Bejan J. A. Jones Professor of Mechanical Engineering Duke University Durham, North Carolina WILEY JOHN WILEY & SONS, INC. CONTENTS Preface Preface to the

More information

Duct Design. Lecturer: 王啟川, PhD Fellow ASME, Fellow ASHRAE Tel: ext

Duct Design. Lecturer: 王啟川, PhD Fellow ASME, Fellow ASHRAE Tel: ext Duct Design Lecturer: 王啟川, PhD Fellow ASME, Fellow ASHRAE Tel: 3-5712121 ext. 55105 E-mail:ccwang@mail.nctu.edu.tw Why duct design is important The efficiency of air distribution systems has been found

More information

DYNAMIC INSULATION APPLIED TO THE RESIDENTIAL BUILDING (PART 2) Numerical Evaluation of Thermal Insulation Effect on Air Supply Window System

DYNAMIC INSULATION APPLIED TO THE RESIDENTIAL BUILDING (PART 2) Numerical Evaluation of Thermal Insulation Effect on Air Supply Window System 3 5 7 8 9 DYNAMIC INSULATION APPLIED TO THE RESIDENTIAL BUILDING (PART ) Numerical Evaluation of Thermal Insulation Effect on Air Supply Window System ABSTRACT Sihwan Lee, Tanaka Miho, Shinsuke Kato 3

More information

Chapter 3 ALGEBRA. Overview. Algebra. 3.1 Linear Equations and Applications 3.2 More Linear Equations 3.3 Equations with Exponents. Section 3.

Chapter 3 ALGEBRA. Overview. Algebra. 3.1 Linear Equations and Applications 3.2 More Linear Equations 3.3 Equations with Exponents. Section 3. 4 Chapter 3 ALGEBRA Overview Algebra 3.1 Linear Equations and Applications 3.2 More Linear Equations 3.3 Equations with Exponents 5 LinearEquations 3+ what = 7? If you have come through arithmetic, the

More information

At any moment, there are 2,000 lightning storms around the world.

At any moment, there are 2,000 lightning storms around the world. 1 2 3 4 5 6 7 8 9 At any moment, there are 2,000 lightning storms around the world. Almost every day someone is struck by lightning. Most of these people survive with lifelong health problems but many

More information

Fouling of HVAC Fin and Tube Heat Exchangers

Fouling of HVAC Fin and Tube Heat Exchangers LBNL-47668 Fouling of HVAC Fin and Tube Heat Exchangers Jeffrey Siegel and Van P. Carey Environmental Energy Technology Division Indoor Environment Department Lawrence Berkeley National Laboratory Berkeley,

More information

Increase Productivity Using CFD Analysis

Increase Productivity Using CFD Analysis Increase Productivity Using CFD Analysis CFD of Process Engineering Plants for Performance Estimation and Redesign Vinod Taneja Vidhitech Solutions Abhishek Jain abhishek@zeusnumerix.com +91 9819009836

More information

Building heat system sizing

Building heat system sizing May 6th, 203 MVK60 Heat and Mass Transfer Project report Building heat system sizing Arnaud BELTOISE Dept. of Energy Sciences, Faculty of Engineering, Lund University, Box 8, 2200 Lund, Sweden . Introduction

More information

A Discussion of Low Reynolds Number Flow for the Two-Dimensional Benchmark Test Case

A Discussion of Low Reynolds Number Flow for the Two-Dimensional Benchmark Test Case A Discussion of Low Reynolds Number Flow for the Two-Dimensional Benchmark Test Case M. Weng, P. V. Nielsen and L. Liu Aalborg University Introduction. The use of CFD in ventilation research has arrived

More information

B.E/B.Tech/M.E/M.Tech : Chemical Engineering Regulation: 2016 PG Specialisation : NA Sub. Code / Sub. Name : CH16304 FLUID MECHANICS Unit : I

B.E/B.Tech/M.E/M.Tech : Chemical Engineering Regulation: 2016 PG Specialisation : NA Sub. Code / Sub. Name : CH16304 FLUID MECHANICS Unit : I Department of Chemical Engineering B.E/B.Tech/M.E/M.Tech : Chemical Engineering Regulation: 2016 PG Specialisation : NA Sub. Code / Sub. Name : CH16304 FLUID MECHANICS Unit : I LP: CH 16304 Rev. No: 00

More information

BUS5 Building structures 5: Fire safety

BUS5 Building structures 5: Fire safety Czech Technical University in Prague FACULTY OF CIVIL ENGINEERING Deptarment of Building Structures BUS5 Building structures 5: Fire safety Excercise 2 Fire Compartments, Fire Risk, Fire Resistance Grades

More information

Darcy's Law. Laboratory 2 HWR 531/431

Darcy's Law. Laboratory 2 HWR 531/431 Darcy's Law Laboratory HWR 531/431-1 Introduction In 1856, Henry Darcy, a French hydraulic engineer, published a report in which he described a series of experiments he had performed in an attempt to quantify

More information

Flow rate and mass flow rate

Flow rate and mass flow rate EEN-E1040 Measurement and control of energy systems Flow measurements / 14 Sep 2017 WELCOME! v. 01 / T. Paloposki Flow rate and mass flow rate Consider the system shown here 1 Volume flow rate through

More information

Laminar and turbulent flows

Laminar and turbulent flows Ventilation 0 Duct Design Vladimír Zmrhal (room no. 84) http://users.fs.cvut.cz/~zmrhavla/index.htm Dpt. Of Environmental Engineering Laminar and turbulent flos Reynolds number d Re = ν laminar flo Re

More information

Principles and Applications of Building Science Dr. E Rajasekar Department of Civil Engineering Indian Institute of Technology, Roorkee

Principles and Applications of Building Science Dr. E Rajasekar Department of Civil Engineering Indian Institute of Technology, Roorkee Principles and Applications of Building Science Dr. E Rajasekar Department of Civil Engineering Indian Institute of Technology, Roorkee Lecture - 04 Thermal Comfort in Built Environment 2 In previous module,

More information

Open PRAIRIE: Open Public Research Access Institutional Repository and Information Exchange

Open PRAIRIE: Open Public Research Access Institutional Repository and Information Exchange South Dakota State University Open PRAIRIE: Open Public Research Access Institutional Repository and Information Exchange Theses and Dissertations 2016 The Effects of Diffuser Exit Velocity and Distance

More information

MDSRC Proceedings, December, 2017 Wah/Pakistan. Cooling load analysis by CLTD and RLF. Sher ali nawaz 1 Muzammil shahbaz 2

MDSRC Proceedings, December, 2017 Wah/Pakistan. Cooling load analysis by CLTD and RLF. Sher ali nawaz 1 Muzammil shahbaz 2 Cooling load analysis by CLTD and RLF Sher ali nawaz 1 Muzammil shahbaz 2 Waqas Javid, M.Umer Sohail Department of mechanical engineering Wah engineering college University of wah sheralinawaz15@gmail.com,

More information

Cdesign must consider (1) space availability, (2) space air diffusion,

Cdesign must consider (1) space availability, (2) space air diffusion, Related Commercial Resources CHAPTER 35 DUCT DESIGN BERNOULLI EQUATION... 35.1 Head and Pressure... 35.2 SYSTEM ANALYSIS... 35.2 Pressure Changes in System... 35.5 FLUID RESISTANCE... 35.6 Friction Losses...

More information

USER GUIDE AIR MINDER PLUS INDOOR AIR QUALITY/HEAT RECOVERY WHOLEHOUSE VENTILATION SYSTEMS FROM IMPORTANT: TO BE LEFT WITH END USER

USER GUIDE AIR MINDER PLUS INDOOR AIR QUALITY/HEAT RECOVERY WHOLEHOUSE VENTILATION SYSTEMS FROM IMPORTANT: TO BE LEFT WITH END USER USER GUIDE AIR MINDER PLUS L E T Y O U R H O M E B R E A T H E INDOOR AIR QUALITY/HEAT RECOERY WHOLEHOUSE ENTILATION SYSTEMS FROM IMPORTANT: TO BE LEFT WITH END USER AIR MINDER PLUS L E T Y O U R H O M

More information

Exercises in Combustion Technology

Exercises in Combustion Technology Exercises in Combustion Technology Exercise 4: Turbulent Premixed Flames Turbulent Flow: Task 1: Estimation of Turbulence Quantities Borghi-Peters diagram for premixed combustion Task 2: Derivation of

More information

Environmental Engineering

Environmental Engineering Environmental Engineering 1 Indoor Environment and Thermal Comfort Vladimír Zmrhal (room no. 814) Master degree course 1 st semester (winter) Dpt. of Environmental Engineering 1 Environmental Engineering

More information

Analysis and Prediction of Air leakage through Door Assemblies

Analysis and Prediction of Air leakage through Door Assemblies Analysis and Prediction of Air leakage through Door Assemblies DANIEL GROSS Center for Fire Research National Bureau of Standards Gaithersburg, Maryland 20899, USA WILLIAM l. HABERMAN Engineering Consultant

More information

Lab Project 4a MATLAB Model of Oscillatory Flow

Lab Project 4a MATLAB Model of Oscillatory Flow Lab Project 4a MATLAB Model of Oscillatory Flow Goals Prepare analytical and computational solutions for transient flow between the two upright arms of a U-shaped tube Compare the theoretical solutions

More information

Duct System Losses Are Total Pressure Losses

Duct System Losses Are Total Pressure Losses Duct System Losses Are Total Pressure Losses Mat Ansari PE Confusion in the use of the terms STATIC PRESSURE and TOTAL PRESSURE is widely prevalent among HVAC Engineers and Contractors. There are serious

More information

Physics 3 Summer 1990 Lab 7 - Hydrodynamics

Physics 3 Summer 1990 Lab 7 - Hydrodynamics Physics 3 Summer 1990 Lab 7 - Hydrodynamics Theory Consider an ideal liquid, one which is incompressible and which has no internal friction, flowing through pipe of varying cross section as shown in figure

More information

Accretion Disks I. High Energy Astrophysics: Accretion Disks I 1/60

Accretion Disks I. High Energy Astrophysics: Accretion Disks I 1/60 Accretion Disks I References: Accretion Power in Astrophysics, J. Frank, A. King and D. Raine. High Energy Astrophysics, Vol. 2, M.S. Longair, Cambridge University Press Active Galactic Nuclei, J.H. Krolik,

More information

Lecture 2 Flow classifications and continuity

Lecture 2 Flow classifications and continuity Lecture 2 Flow classifications and continuity Dr Tim Gough: t.gough@bradford.ac.uk General information 1 No tutorial week 3 3 rd October 2013 this Thursday. Attempt tutorial based on examples from today

More information

Decay of Rotational Airflow with Flow Conditioner in Larger Diameter Ducts for Dust Concentration Measurement using Isokinetic Sampling

Decay of Rotational Airflow with Flow Conditioner in Larger Diameter Ducts for Dust Concentration Measurement using Isokinetic Sampling 1 Decay of Rotational Airflow with Flow Conditioner in Larger Diameter Ducts for Dust Concentration Measurement using Isokinetic Sampling Z. C. Tan, Y. Zhang, S. E. Ford Department of Agricultural and

More information

Increasing Energy Efficiency of HVAC Systems in Buildings Using Phase Change Material

Increasing Energy Efficiency of HVAC Systems in Buildings Using Phase Change Material Washington University in St. Louis Washington University Open Scholarship All Theses and Dissertations (ETDs) January 2011 Increasing Energy Efficiency of HVAC Systems in Buildings Using Phase Change Material

More information

DEVELOPEMENT OF MODIFIED THERMAL COMFORT EQUATION FOR A ROOM WITH WINDOW OPENINGS AT ADJACENT WALLS

DEVELOPEMENT OF MODIFIED THERMAL COMFORT EQUATION FOR A ROOM WITH WINDOW OPENINGS AT ADJACENT WALLS DEVELOPEMENT OF MODIFIED THERMAL COMFORT EQUATION FOR A ROOM WITH WINDOW OPENINGS AT ADJACENT WALLS D.Prakash 1, P.Ravikumar 2 1 Research scholar, Mechanical Engineering department, Anna University, Tamil

More information

The energy performance of an airflow window

The energy performance of an airflow window The energy performance of an airflow window B.(Bram) Kersten / id.nr. 0667606 University of Technology Eindhoven, department of Architecture Building and Planning, unit Building Physics and Systems. 10-08-2011

More information

Evaluation of the Convective Heat Transfer Coefficient of the Human Body Using the Wind Tunnel and Thermal Manikin

Evaluation of the Convective Heat Transfer Coefficient of the Human Body Using the Wind Tunnel and Thermal Manikin Evaluation of the Convective Heat Transfer Coefficient of the Human Body Using the Wind Tunnel and Thermal Manikin 1, Shinsuke Kato 2 and Janghoo Seo* 3 1 Assistant Professor, School of Architecture, Yeungnam

More information

Cdesign must consider (1) space availability, (2) space air

Cdesign must consider (1) space availability, (2) space air ASHRAE Fundimental CHAPChTER 32 DUCT DESIGN Bernoulli Equation.... 32.1 Head and Pressure.... 32.2 SYSTEM ANALYSIS.... 32.2 Pressure Changes in System.... 32.6 FLUID RESISTANCE.... 32.7 Friction Losses....

More information

IMPACT OF THE ATMOSPHERIC BOUNDARY LAYER PROFILE ON THE VENTILATION OF A CUBIC BUILDING WITH TWO LARGE OPPOSITE OPENINGS

IMPACT OF THE ATMOSPHERIC BOUNDARY LAYER PROFILE ON THE VENTILATION OF A CUBIC BUILDING WITH TWO LARGE OPPOSITE OPENINGS Ninth International IBPSA Conference Montréal, Canada August 15-18, 2005 IMPACT OF THE ATMOSPHERIC BOUNDARY LAYER PROFILE ON THE VENTILATION OF A CUBIC BUILDING WITH TWO LARGE OPPOSITE OPENINGS Alain BASTIDE,

More information

Hovercraft. Nikolay Sibiryakov

Hovercraft. Nikolay Sibiryakov 1 Hovercraft Nikolay Sibiryakov The problem 2 A simple model hovercraft can be built using a CD and a balloon filled with air attached via a tube. Exiting air can lift the device making it float over a

More information

Parametric Study of Rock Bed Thermal Regenerator for Space Heating

Parametric Study of Rock Bed Thermal Regenerator for Space Heating RESEARCH ARTICLE OPEN ACCESS Parametric Study of Rock Bed Thermal Regenerator for Space Heating Neeraj Tewari, Manish Bhendura, Mithleshupadhyay, D.S. Murthy Mechanical Engineering Department, College

More information

Fundamentals of WUFI-Plus WUFI Workshop NTNU / SINTEF 2008

Fundamentals of WUFI-Plus WUFI Workshop NTNU / SINTEF 2008 Fundamentals of WUFI-Plus WUFI Workshop NTNU / SINTEF 2008 Simultaneous Calculation of Transient Hygrothermal Conditions of Indoor Spaces and Building Envelopes boundary conditions Building envelope Outdoor

More information

SIMILARITY SOLUTION FOR DOUBLE NATURAL CONVECTION WITH DISPERSION FROM SOURCES IN AN INFINITE POROUS MEDIUM

SIMILARITY SOLUTION FOR DOUBLE NATURAL CONVECTION WITH DISPERSION FROM SOURCES IN AN INFINITE POROUS MEDIUM Proceedings NZ GeothermalWorkshop SIMILARITY SOLUTION FOR DOUBLE NATURAL CONVECTION WITH DISPERSION FROM SOURCES IN AN INFINITE POROUS MEDIUM A.V. and A. F. Geothermal Institute, The University of Auckland,

More information

OUTCOME 2 - TUTORIAL 1

OUTCOME 2 - TUTORIAL 1 Unit 4: Heat Transfer and Combustion Unit code: K/60/44 QCF level: 5 Credit value: 5 OUTCOME - TUTORIAL Heat transfer coefficients Dimensional analysis: dimensionless groups; Reynolds, Nusselt, Prandtl,

More information

Analysis of Natural Wind Characteristics and Review of Their Correlations with Human Thermal Sense through Actual Measurements

Analysis of Natural Wind Characteristics and Review of Their Correlations with Human Thermal Sense through Actual Measurements Analysis of Natural Wind Characteristics and Review of Their Correlations with Human Thermal Sense through Actual Measurements Ki Nam Kang 1,a, Jin Yu 1,b, Doo Sam Song 2,c, Hee Jung Ham 3,d, Kook Jeong

More information

3.185 ABET Statements

3.185 ABET Statements 3.185 ABET Statements Adam Powell Fall semester, 2003 1 Subject objectives and outcomes Objectives 1. Give students an understanding of conservation laws and constitutive equations as they apply to convective

More information

Darcy s Law. Darcy s Law

Darcy s Law. Darcy s Law Darcy s Law Last time Groundwater flow is in response to gradients of mechanical energy Three types Potential Kinetic Kinetic energy is usually not important in groundwater Elastic (compressional) Fluid

More information

BSE Public CPD Lecture Numerical Simulation of Thermal Comfort and Contaminant Transport in Rooms with UFAD system on 26 March 2010

BSE Public CPD Lecture Numerical Simulation of Thermal Comfort and Contaminant Transport in Rooms with UFAD system on 26 March 2010 BSE Public CPD Lecture Numerical Simulation of Thermal Comfort and Contaminant Transport in Rooms with UFAD system on 26 March 2010 Organized by the Department of Building Services Engineering, a public

More information

* 1 K.Mohan Laxmi, 2 V.Ranjith Kumar, 3 Y.V.Hanumantha Rao

* 1 K.Mohan Laxmi, 2 V.Ranjith Kumar, 3 Y.V.Hanumantha Rao Modeling And Simulation of Gas Flow Velocity In Catalytic Converter With Porous * 1 K.Mohan Laxmi, 2 V.Ranjith Kumar, 3 Y.V.Hanumantha Rao 1 M.Tech Student, Mechanical Engineering Department, KL University,

More information

NUMERICAL MODELLING OF TEMPERATURE AND AIR FLOW DISTRIBUTION IN ENCLOSED ROOM

NUMERICAL MODELLING OF TEMPERATURE AND AIR FLOW DISTRIBUTION IN ENCLOSED ROOM NUMERICAL MODELLING OF TEMPERATURE AND AIR FLOW DISTRIBUTION IN ENCLOSED ROOM Igor Bonefacic 1, Bernard Frankovic 2, Ivan Vilicic 3, Vladimir Glazar 4 Faculty of Engineering, Vukovarska 58, Rijeka, Croatia,

More information

Air Flow through Woven Stainless Steel Mesh

Air Flow through Woven Stainless Steel Mesh Air Flow through Woven Stainless Steel Mesh Abstract It was known that a mesh screen placed across an airflow will have an evening effect, distributing both the velocity and pressure across the screen,

More information

Standard Operating Procedure

Standard Operating Procedure Standard Operating Procedure Procedure: Emergency Weather Plan - Events Department/Division: Section: Date Originated: Culture & Recreation April 30, 2013 Approval: Approval: Date Revised: Reference: HUR130-016

More information

Healthy Buildings 2017 Europe July 2-5, 2017, Lublin, Poland

Healthy Buildings 2017 Europe July 2-5, 2017, Lublin, Poland Healthy Buildings 2017 Europe July 2-5, 2017, Lublin, Poland Paper ID 0076 ISBN: 978-83-7947-232-1 Experimental Study of the Airflow Distribution Close to the Human Body with a Downward Plane Jet Marie

More information

Design for Airtightness and Moisture Control in New Zealand housing

Design for Airtightness and Moisture Control in New Zealand housing Design for Airtightness and Moisture Control in housing paola leardini the university of auckland [school of architecture & planning] thomas van raamsdonk pro clima nz limited current issues Indoor Air

More information

Chemistry Metric Dimensional Analysis Answers

Chemistry Metric Dimensional Analysis Answers Chemistry Metric Answers Free PDF ebook Download: Chemistry Metric Answers Download or Read Online ebook chemistry metric dimensional analysis answers in PDF Format From The Best User Guide Database &

More information

Ph.D. Qualifying Examination in Heat Transfer

Ph.D. Qualifying Examination in Heat Transfer Student # Department of Mechanical Engineering Michigan State University East Lansing, Michigan Ph.D. Qualifying Examination in Heat Transfer One open book. Answer questions 1 and 4 and either of 2 or

More information

AN EXPERIMENTAL STUDY AND ANALYSIS ON VENT CAP PERFORMANCE. A Thesis DANIEL SANTIAGO ESCATEL

AN EXPERIMENTAL STUDY AND ANALYSIS ON VENT CAP PERFORMANCE. A Thesis DANIEL SANTIAGO ESCATEL AN EXPERIMENTAL STUDY AND ANALYSIS ON VENT CAP PERFORMANCE A Thesis by DANIEL SANTIAGO ESCATEL Submitted to the Office of Graduate Studies of Texas A&M University in partial fulfillment of the requirements

More information

Whether you are driving or walking, if you come to a flooded road, Turn Around Don't Drown

Whether you are driving or walking, if you come to a flooded road, Turn Around Don't Drown Whether you are driving or walking, if you come to a flooded road, Turn Around Don't Drown You will not know the depth of the water nor will you know the condition of the road under the water. Many people

More information

Journal of Chemical and Pharmaceutical Research, 2014, 6(6): Research Article

Journal of Chemical and Pharmaceutical Research, 2014, 6(6): Research Article Available online www.ocpr.com Journal of Chemical and Pharmaceutical Research, 201, 6(6):1777-1782 Research Article ISSN : 0975-738 CODEN(USA) : JCPRC5 Numerical Simulation of smoke movement in vertical

More information

FLOW MEASUREMENT IN PIPES EXPERIMENT

FLOW MEASUREMENT IN PIPES EXPERIMENT University of Leicester Engineering Department FLOW MEASUREMENT IN PIPES EXPERIMENT Page 1 FORMAL LABORATORY REPORT Name of the experiment: FLOW MEASUREMENT IN PIPES Author: Apollin nana chaazou Partner

More information

Introduction. 1. Safety and chemical exposure

Introduction. 1. Safety and chemical exposure Mitigating health risks with laboratory fume hoods Dominique Laloux,General Manager, Kunshan Erlab DFSL, China Teddy Pitot, Area Sales Manager, Erlab Southeast Asia, Malaysia Introduction Safety is a very

More information

SCHOOL OF CHEMICAL ENGINEERING FACULTY OF ENGINEERING AND TECHNOLOGY SRM UNIVERSITY COURSE PLAN

SCHOOL OF CHEMICAL ENGINEERING FACULTY OF ENGINEERING AND TECHNOLOGY SRM UNIVERSITY COURSE PLAN SCHOOL OF CHEMICAL ENGINEERING FACULTY OF ENGINEERING AND TECHNOLOGY SRM UNIVERSITY COURSE PLAN Course code : CH0317 Course Title : Momentum Transfer Semester : V Course Time : July Nov 2011 Required Text

More information

COURSE CODE : 3072 COURSE CATEGORY : B PERIODS/ WEEK : 5 PERIODS/ SEMESTER : 75 CREDIT : 5 TIME SCHEDULE

COURSE CODE : 3072 COURSE CATEGORY : B PERIODS/ WEEK : 5 PERIODS/ SEMESTER : 75 CREDIT : 5 TIME SCHEDULE COURSE TITLE : FLUID MECHANICS COURSE CODE : 307 COURSE CATEGORY : B PERIODS/ WEEK : 5 PERIODS/ SEMESTER : 75 CREDIT : 5 TIME SCHEDULE MODULE TOPIC PERIOD 1 Properties of Fluids 0 Fluid Friction and Flow

More information