1 Iso Catalog /23/99 9:20 PM Page 1

2 Iso Catalog /23/99 9:20 PM Page 56 HI G H IN T E N S I T Y GA M M A RA Y SO U R C E S (HEG A N D HEGL SE R I E S) This group of sources includes gamma emitters with energies greater than 300 kev which are suitable for a variety of field uses including survey instrument calibration and industrial gauging applications. Two basic types are cataloged: the HEG series of point sources and the HEGL series of line sources. All source capsules are made of doubly encapsulated, welded 304 stainless steel. All sources have been assigned a classification number in accordance with ANSI N and meet minimum standards for their application. Most capsules meet D.O.T. Special Form requirements. The active elements of the HEG point sources are ceramic unless otherwise indicated. Contained activity is normally held to within ±15% of the stated value unless quoted on a different basis. NIST traceability and output calibrations are available on request. The HEGL line sources may contain one of several forms of active material including ceramic, resin, or carbon substrates. All line sources are produced on a custom basis. Requests for quotations should include contained activity required, active and overall length, diameter limitations and uniformity requirements. Typical activities range up to 10 mci per cm and lengths to 80 cm. Uniformity is normally held to within ±15%, however, sources for medical application are prepared to a much tighter tolerance. Call customer service for information on specific models. Most sources are shipped in non-returnable D.O.T. 7A Type A containers. Certain products labeled with an asterisk require a wooden shipping container and lead insert. This container becomes the customer s property, and is suitable in most cases for permanent storage. There is an additional charge for this container CAPSULE 3023 CAPSULE 3024 CAPSULE 3015 CAPSULE 3011 CAPSULE 3809 CAPSULE 3814 CAPSULE 3833 CAPSULE FIGURE 56-A HIGH INTENSITY GAMMA RAY SOURCES (HEG SERIES)

3 Iso Catalog /23/99 9:20 PM Page 57 HI G H IN T E N S I T Y GA M M A RA Y SO U R C E S (HEG A N D HEGL SE R I E S) Source capsules: Series 225: The model 225 capsule may be configured in several capsule geometries as shown in the following table. The standard Model 225 capsule is Catalog #3000. C A P S U L E O V E R A L L O V E R A L L ACTIVE LENGTH * A C T I V E N U M B E R L E N G T H D I A M E T E R D I A M E T E R (Standard 225) (15.9 mm) (6.35 mm) ( mm) (3.18 mm) (8.00 mm) (5.99 mm) ( mm) (3.18 mm) " (12.0 mm) (5.99 mm) ( mm) (3.18 mm) (10.0 mm) (5.99 mm) ( mm) (3.18 mm) *Typical active length is (0.762mm) Series 193: C A P S U L E O V E R A L L O V E R A L L ACTIVE LENGTH* A C T I V E N U M B E R L E N G T H D I A M E T E R D I A M E T E R (0.635 mm) (Standard 193) (36.5 mm) hex width ( mm) (3.18 mm) (9.53 mm hex width) * Typical active length is (0.762 mm) Additional Point Source Capsules: CAPSULE O V E R A L L O V E R A L L ACTIVE LENGTH* A C T I V E N U M B E R L E N G T H D I A M E T E R D I A M E T E R " 0.108" N/A " (10.4 mm) (2.74 mm) (0.30 mm) " " 0.110" " (5.08 mm) (1.52 mm) (2.8 mm) (0.76 mm) 3833 N/A 0.156" N/A " (3.96 mm) N/A (0.30 mm) Line Source Capsules: CAPSULE OVERALL O V E R A L L A C T I V E A C T I V E NUMBER L E N G T H DIAMETER LENGTH D I A M E T E R 3402 * 0.120" 1" - 33" " (3.05 mm) (25.4 mm-838 mm) (1.52 mm) * " " " (4.75 mm) (12.7 mm m) (3.23 mm) * 0.187" " " *Overall length per customer's specification. See drawings page 61. (4.75 mm) (12.7 mm m) (3.23 mm) To place an order: Phone FAX Please include the catalog number, the capsule or configuration number, the nuclide, the activity and any NIST traceability requirements.

4 Iso Catalog /23/99 9:21 PM Page 58 HI G H IN T E N S I T Y GA M M A RA Y SO U R C E S (HEG A N D HEGL SE R I E S) H E G Point Sources B a r i u m H a l f-l i f e : y Principal gammas (kev): 81 (34.2%), 276 (7.09%), 303 (18.4%), 356 (62.2%), 384 (8.92%), OUTER CAPSULE WELD FIGURE 58-A 3000 CAPSULE (225 CAPSULE) Cs K x-rays: 30 (123%) 0.625" (15.9 mm) Radiochemical purity: 99% Cs-134 <0.5% Active element: 1 m: Barium in ceramic or aluminum matrix ( Gy) CATALOG NUMBER m C i M B q H E G H E G " (6.35 mm) INNER OUTER INNER CAPSULE ANSI D.O.T. SPECIAL FORM H E G H E G H E G L O R O R INNER CAPSULE 0.315" (8 mm) FUSION WELD FIGURE 58-B 3023 CAPSULE 0.236" (6 mm) ANSI D.O.T. SPECIAL FORM INNER 3-48 UNC-2B 0.156" (3.96 mm) OUTER CAPSULE OUTER 0.394" (10 mm) FUSION WELD FIGURE 58-C 3024 CAPSULE ANSI D.O.T. SPECIAL FORM 0.236" (6 mm) 0.125" (3.18 mm) OUTER INNER CAPSULE 0.090" (2.29 mm) INNER OUTER CAPSULE OUTER CAPSULE FIGURE 58-D 3015 CAPSULE 0.315" (8 mm) FUSION WELD OUTER 0.236" (6 mm) ANSI D.O.T. SPECIAL FORM INNER CAPSULE INNER

5 Iso Catalog /23/99 9:21 PM Page 59 HI G H IN T E N S I T Y GA M M A RA Y SO U R C E S (HEG A N D HEGL SE R I E S) H E G Point Sources C e s i u m H a l f-l i f e : Principal gamma (kev): 30.2 y 662 (85.2% from Ba-137m), Ba K x- rays: (7%) Radiochemical purity: > 9 9 % Active element: 1 m: CsCl in ceramic m a t r i x 0.33 ( Gy) CATALOG NUMBER m C i M B q H E G H E G H E G H E G H E G H E G H E G HEG * HEG * HEGL O R O R * Requires a shielded shipping container C o b a l t-6 0 H a l f-l i f e : 5.27 y Principal gammas (kev): 1173 (100%), 1333 ( % ) Radiochemical purity: > 9 9 % Active element: 1 m: Cobalt metal or CoCl in ceramic matrix 1.32 ( Gy) CATALOG NUMBER m C i M B q H E G HEG-60-5 * HEG * H E G L O R O R * Requires shielded shipping container G e r m a n i u m - 68/G a l l i u m (For Use In Pet Scanners) H a l f - l i f e : d/1.35 d Principal Gammas (kev): 511 (178%, annihilation peak) 1077 (3%) Radiochemical purity : > % Active element: 1 m: HI G H IN T E N S I T Y GA M M A RA Y SO U R C E S (HEG A N D HEGL SE R I E S) S o d i u m Half-life: 2.60 y Principal Gammas (kev): % 511 (178.8%, annihilation peak) Radiochemical purity: 99.9% Not determined Active element: R / h / C 1 m: ceramic, epoxy or deposited 1.20 (0.012 Gy) (gamma only) CATALOG NUMBER m C i M B q H E G O R O R H E G L O R O R Not Determined ceramic or epoxy 0.52 ( Gy) CATALOG NUMBER m C i M B q H E G O R O R Refer to pages for additional line source inform a t i o n. To place an order: Phone FAX Please include the catalog number, the capsule or configuration number, the nuclide, the activity and any NIST traceability requirements.

6 Iso Catalog /23/99 9:21 PM Page 60 HI G H IN T E N S I T Y GA M M A SO U R C E S (HEG A N D HEGL SE R I E S) OUTER 8-32 THD " (7.94 mm) " (1.59 m m) H O L E 0.875" (22.2 mm) MAX. LENGTH 1.5" (38.1 mm) HEX. WIDTH 0.375" (9.53 mm) " (6.35 m m ) INNER INNER CAPSULE OUTER CAPSULE ANSI D.O.T. SPECIAL FORM FIGURE 60-A 3011 CAPSULE (193 CAPSULE) CAPSULE E.B. WELD FIGURE 60-B 3814 CAPSULE 0.060" (1.52 mm) 0.200" (5.08 mm) (0.91 mm) FIGURE 60-C 3833 CAPSULE EPOXY CAP 0.091" (2.31 mm) 0.12" (3.05mm) NORMAL DRILL ANGLE 0.156" (3.96 mm) 0.410" (10.4 mm) FUSION WELD FIGURE 60-D 3809 CAPSULE 0.108" (2.74 mm) 0.083" (2.11 mm) CAPSULE ANSI 32242

7 Iso Catalog /23/99 9:21 PM Page 61 HI G H IN T E N S I T Y GA M M A SO U R C E S (HEGL SE R I E S) TYPE 304 STAINLESS STEEL TUBING INNER OUTER WELDS COLD WELDED ENDS 0.187" (4.75 mm) COPPER OR ALUMINUM TUBING 0.120" (3.05 mm) ANSI D.O.T. SPECIAL FORM FIGURE 61-B 3321 CAPSULE (Kr -85 GAMMA LINE SOURCE) FIGURE 61-A 3402 CAPSULE (301B LINE SOURCE) ALUMINUM MOUNTING BLOCK ALUMINUM OR COPPER TUBE PROTECTIVE GRID (OPTIONAL) MOUNTING HOLES FIGURE 61-C OPTIONAL HOLDER FOR Kr -85 LINE SOURCE FIGURE 61-D 3402 AND 3321 CAPSULES To place an order: Phone FAX Please include the catalog number, the capsule or configuration number, the nuclide, the activity and any NIST traceability requirements.

8 Iso Catalog /23/99 9:21 PM Page 62 BE T A SO U R C E S ( B F I SE R I E S) The BFI Series consists of three basic models: the BFI point sources, the BFIL line sources, the Micropoint beta sources. The Micropoint beta source s active element is only 0.118" (3 mm) in d i a m e t e r " (22 mm) 0.837" (21.3 mm) MOUNTING HOLES COPPER PINCH-OFF The beta sources described below cover the energy range from 18 to 2282 kev, and are intended primarily for industrial gauging and for instrument calibration under field conditions. Except for the Kr-85 gas filled sources, the active element is a monolithic construction with the radionuclide incorporated into a ceramic pellet, a metallic foil or polymeric matrix. The element is further encapsulated to give a high integrity source in which the activity will not shift under the most extreme conditions likely to be encountered in field operation. The nuclides available in the 3200 series capsule have been tested in accordance with ANSI The Series 3200 capsules can also be furnished in an A-2F flanged mount. Some of the applications for these sources are: transmission gauging of thin sheet stock backscatter gauging of thin coatings aircraft ice detectors internal standards in portable survey instruments and control instrumentation high intensity point and line sources for calibration of beta spectrometers static elimination and other ionizing a p p l i c a t i o n s dust monitoring instruments hot particle studies. The various capsule styles available for these applications are pictured in the next section of this catalog. RING (OPTIONAL) Point Sources C a r b o n H a l f - l i f e : 5730 y Beta energy E M A X ( k e V ) : 156 All C-14 sources are prepared to order. Active diameters range from to (3 mm to 20 mm) with activities up to 10 mci/cm 2 (370 MBq/cm 2 ). The active deposit consists of a polymeric matrix covered with a 1-2 mg/cm 2 polyimide cover. K r y p t o n-85 Gas Sources BFI-85 Point Source H a l f - l i f e : y Beta energy E M A X ( k e V ) : The BFI-85 sources are all-welded stainless steel or titanium capsules loaded with Kr-85 gas and supplied in the 3320 capsule. Enrichment is usually about 6%, corresponding to 60 mci/cc (2.22 STP. Contained activity is supplied as a nominal value ±15%. Information on higher enrichments of Kr-85 available on r e q u e s t. WINDOW BODY WELD ALL AROUND CAP FIGURE 62-A 3320 CAPSULE (K r- 8 5 ) FIGURE 62-B 3320 CAPSULE (K r- 8 5 ) S p e c i f i c a t i o n s : Capsule type: Capsule pressure: approximately 100 psig m a x i m u m Overall diameter: (22.0 mm) Overall length: (21.3 mm) Capsule material: 304 stainless steel (1) Active diameter: Window: (17.0 mm) ( mm) stainless steel or titanium CATALOG A C T I V I T Y ACTIVITY N U M B E R ( m C i ) ( G B q ) B F I B F I B F I B F I B F I B F I B F I B F I B F I (1) Titanium capsule available on request

9 Iso Catalog /23/99 9:21 PM Page 63 BE T A SO U R C E S (BFI SE R I E S) Kr-85 Beta Line Sources (BFIL-85) Capsule No Copper tubing Capsule No Aluminum tubing Beta Line Sources are available in lengths from 0.25 to 25 (6.35 mm to 635 mm) with loading up to 1 mci/cm (37 MBq/cm) of Kr-85 at normally available enrichments. Contained activity is held to within ±15% of the nominal value. COLD WELDED ENDS The shorter length sources are useful as internal check sources for portable survey instruments, while longer sections have applications in static elimination and process thickness gauging of various plastic sheets. Tubing is diameter x wall (1.57 mm x.076 mm) copper or diameter x (2.34 mm x mm) aluminum, depending on the application. The ends are sealed by cold welding techniques. Sources can be furnished fabricated or mounted in holders per the user s specifications. N i c k e l-6 3 The BFI-63 active element is high specific activity nickel-63 electrodeposited on a polished copper disk 0.01 (0.254 mm) thick. Other foils and special shapes are available on request. H a l f - l i f e : Beta energy E M A X ( k e V ) : y C A T A L O G A C T I V I T Y A C T I V I T Y N U M B E R ( m C i ) ( M B q ) B F I B F I B F I B F I Capsule Type: Custom designs Higher activities in different capsules are available on r e q u e s t " (3.18 mm) P r o m e t h i u m The BFI-147 active element consists of an insoluble promethium salt in a ceramic matrix with a thin nickel window or on polymeric membrane. H a l f - l i f e : Beta energy E M A X ( k e V ) : 2.62 y 225 A significant amount of Bremsstrahlung (x-ray) radiation is emitted by shielding m a t e r i a l s. C A T A L O G A C T I V I T Y A C T I V I T Y A C T I V E N U M B E R ( m C i ) ( M B q ) D I A M E T E R B F I mm B F I mm B F I mm B F I mm Capsule type: Custom designs Higher activities are available on request. COPPER OR ALUMINUM TUBING FIGURE 63-A CAPSULE NO R u t h e n i u m / R h o d i u m Kr -85 BETA LINE SOURCE The BFI-106 active element is a ceramic disk or metallic pellet encapsulated in a welded 3203* (GFS series) capsule with a ( mm welded stainless steel window. H a l f-life: 1.02 y Beta energy E M A X (kev): 39 from Ru-106, 354 from Rh-106. Significant gamma radiation in the range kev is emitted by R h C A T A L O G A C T I V I T Y A C T I V I T Y N U M B E R ( m C i ) ( M B q ) B F I B F I B F I B F I B F I Active Diameter: 0.19 (4.83 mm) Capsule type: 3203 (GFS Series) *3203 is equivalent to the GFS-3 capsule with a ss window. To place an order: Phone FAX Please include the catalog number, the capsule or configuration number, the nuclide, the activity and any NIST traceability requirements.

10 Iso Catalog /23/99 9:21 PM Page 64 BE T A SO U R C E S (BFI SE R I E S) S t r o n t i u m-9 0 / Y t t r i u m - 90 The BFI-90 active element is an insoluble strontium salt dispersed in a ceramic matrix. Contained activity is supplied as a nominal value ±15% NIST calibration (±11% at the 99% confidence level) of the contained activity is available on request. Sr-90/Y-90 is also available in a titanium capsule, Model 3712, which may be supplied with a 6 handle for easy m a n i p u l a t i o n. Versions of the 3203 (GFS Series) capsule with smaller active diameters are available on special order. H a l f-l i f e : 28.5 y Beta energies E M A X (kev): 554 from Sr-90, 2274 from Y-90. A significant amount of Bremsstrahlung ( x-ray) radiation is emitted by shielding m a t e r i a l s. Micropoint beta point sources (BFIM) These sources are primarily designed for use in commercial beta backscatter gauges requiring an extremely small point source of beta radiation (0.012", 0.3 mm). In addition to beta backscatter, typical applications include hot particle standards, mapping detector sensitivities, and transmission thickness gauging. These sources are registered with the State of California as Model TCB-1 and have an ANSI classification of C C A T A L O G N U C L I D E C A P S U L E W I N D O W O U T S I D E E M A X (k e V) ACTIVITY RANGE N O M A T E R I A L M A T E R I A L D I A M E T E R B F I M-090 Sr-90/Y-90 P t / I r 2.2 mg/cm 2 Ti 0.050" (1.27 mm) 2280 up to 25 µci (925 kbq) B F I M-147 Pm-147 N i c k e l 2.0 mg/cm 2 Ni 0.022" (0.559 mm) 240 up to 1200 µci (44.4 MBq) B F I M-204 Ti-204 P t / I r 2.2 mg/cm 2 Ti 0.022" (0.559 mm) 763 up to 100 µci (3.7 MBq) C A T A L O G N U M B E R ACTIVITY ACTIVITY B F I µci 37 kbq B F I µci 370 kbq B F I µci 925 kbq B F I µci 1.85 MBq B F I µci 3.7 MBq B F I µci 18.5 MBq B F I M 1 mci 37 MBq B F I M 2 mci 74 MBq B F I M 5 mci 185 MBq B F I M 10 mci 370 MBq B F I L O R O R Active diameter: (6.35 mm) Capsule: 3203* (GFS Series) *3203 is equivalent to the GFS-3 capsule with a ss window. FIGURE 64-A BFIL-85 AND BFIM SOURCES EPOXY SEAL 0.050" (1.27mm) DIA (1.35mm) 0.180" (4.57 mm) FIGURE 64-B BFIM SERIES POINT SOURCE Sr- 9 0 WINDOW BODY (1.91mm) (2.54mm) 0.180" (4.57 mm) 0.014" (0.356 mm) WINDOW ACTIVE DIAMETER (0.559mm EPOXY IN PLACE EPOXY FILL FIGURE 64-C BFIM SERIES POINT SOURCE Pm-147 AND Tl

11 Iso Catalog /23/99 9:21 PM Page 65 LO W EN E R G Y X - RA Y AN D GA M M A RA Y SO U R C E S Source Configurations ( XFB & GFS Series) This series of radiation sources is rugged capsule configurations intended primarily for XRF and gauging applications in the field requiring photon energies from 6 to 125 kev. GFS Series Configurations Two basic point source styles are utilized: The GFS series is an all stainless steel configuration and is normally used for energies from kev. The XFB series capsule which is fitted with a high temperature brazed beryllium window and is employed for emissions below 50 kev. Both series have been expanded and assigned new 3000 series numbers to accommodate a large combination of window and backing materials which optimize emission characteristics. Most source configurations have been tested and assigned ANSI classifications. Some sources are classified as D.O.T. Special Form. C A P S U L E W I N D O W S P A C E R A C T I V E O V E R A L L O V E R A L L REGISTERED UNDER D. O. T. N U M B E R (STAINLESS STEEL) D I A M E T E R D I A M E T E R L E N G T H S E R I E S SPECIAL FORM N o n e G F S - 3 Y e s (Standard Capsule) ( m m ) (5.33 mm) (7.92 mm) (5.08) mm T u n g s t e n G F S - 3 Yes (0.254 mm) (5.33 mm) (7.92 mm) (5.08) mm A l u m i n u m G F S - 3 Y e s ( mm) (6.35 mm) (7.92 mm) (5.08) mm N o n e G F S - 5 No (0.254 mm) (11.4 mm) (12.7 mm) (5.08) mm N o n e N o t Y e s ( mm) (4.75 mm) (9.53 mm) (7.87 mm) R e g i s t e r e d N o n e G F S - 3 Yes (0.254 mm) (2.03 mm) (3 mm) (10 mm) N o n e G F S - 3 Y e s (0.254 mm) (3.05 mm) (3.99 mm) (10 mm) N o n e G F S - 3 Y e s (0.254 mm) (4.75 mm) (6.99 mm) (10 mm) N o n e G F S - 3 Y e s (0.254 mm) (0.889 mm) (3.05 mm) (10.2 mm) All capsules can be furnished in the auxiliary type A-2F flanged holder shown on Page 66, which provides a convenient means of mounting in an instrument or device CAPSULE 3203 CAPSULE 3222 CAPSULE 3807 CAPSULE 3217 CAPSULE 3215 CAPSULE 3204 CAPSULE FIGURE 65-A XFB AND GFS SERIES Also included are a series of line sources suitable for use in gauging with energies 60 kev and higher. XFB and GFS Capsules This line of sources uses a variety of window and backing materials to maximize critical emissions through the window end of the source and, if desired, reduce emissions from the back end. This type of integral shielding can simplify external holder and shielding assemblies. Contact Technical Customer Service for further i n f o r m a t i o n.

12 Iso Catalog /23/99 9:21 PM Page 66 LO W EN E R G Y X - RA Y AN D GA M M A RA Y SO U R C E S (GFS SE R I E S CO N F I G U R A T I O N S) 0.200" (5.08 mm) 0.01" (0.254 mm) FUSION WELD CAPSULE INTEGRAL WINDOW.010" 0.200" (5.08 mm) ACTIVE ELEMENT 0.312" (7.92 mm) 0.312" (7.92 mm) INTEGRAL WINDOW D.O.T. SPECIAL FORM ACTIVE ELEMENT SHIELD TUNGSTEN ALLOY CAPSULE D.O.T. SPECIAL FORM 0.200" (5.08 mm) FUSION WELD FIGURE 66-A 3201 CAPSULE (GFS-3) FIGURE 66-B 3202 CAPSULE 0.394" (10 mm) FUSION WELD 0.312" (7.92 mm) A DIA B DIA D.O.T. SPECIAL FORM D.O.T. SPECIAL FORM ACTIVE WELD A B "(3.0 mm) 0.080"(2.03 mm) "(3.99 mm) 0.120"(3.05 mm) "(6.99 mm) 0.187"(4.75 mm) FIGURE 66-C 3224 CAPSULE FUSION WELD CAPSULE ALUMINUM SHIELD.002 (0.051 mm)st. STL WINDOW FIGURE 66-D 3203 CAPSULE GFS-3 WITH 0.002" SS WINDOW 0.310" (7.87 mm) CAPSULE 0.375" (9.53 mm) 0.200" (5.08 mm) (8.33 mm) ACTIVE ELEMENT STD. HEX SOCKET 0.156"(3.96mm) ACROSS FLATS E.B.WELD D.O.T. SPECIAL FORM WINDOW 0.010" (.254 mm) 0.447" (11.4 mm) 0.500" (12.7 mm) E.B. WELD 0.002" (.051 mm) ST.STL. WINDOW 304 ST. STL. FIGURE 66-F 3217 CAPSULE (GFS-5) FIGURE 66-E 3222 CAPSULE (343 THREADED CAPSULE) 1.0" (25.4 mm) CAPSULE 304 ST STL WELD 0.562" (14.3 mm) 0.120" (3.05 mm) 0.400" (10.2 mm) CLEARANCE FOR NO. 6 SCREW 0.562" (14.27 mm) O.D " (.76 mm) D.O.T. SPECIAL FORM 0.250" (6.35 mm) FIGURE 66-G 3807 CAPSULE 0.125" (3.18 mm) 0.75" (19.1 mm) FIGURE 66-H A2F FLANGE MOUNT

13 Iso Catalog /23/99 9:21 PM Page 67 LO W EN E R G Y X - RA Y AN D GA M M A RA Y SO U R C E S XFB Series Configurations C A P S U L E W I N D O W S P A C E R ACTIVE OVERALL O V E R A L L R E G I S T E R E D D. O. T. N U M B E R ( B E R Y L L I U M ) D I A M E T E R D I A M E T E R L E N G T H U N D E R S P E C I A L S E R I E S F O R M N o n e X F B - 3 Yes (0.254 mm) (5.08 mm) (7.93 mm) (5.08 mm) T u n g s t e n X F B - 3 Y e s (1.02 mm) (5.08 mm) (7.93 mm) (5.08 mm) N o n e X F B - 5 N o (0.254 mm) (11.1 mm) (12.7 mm) (5.08 mm) 0.200" (5.08 mm) FUSION WELD TUNGSTEN SPACER WINDOW 0.040" Be FOIL 0.200" (5.08 mm) 0.312" (7.92 mm) 0.200" (5.08 mm) 0.312" (7.92mm) D.O.T. SPECIAL FORM WINDOW.010" Be FOIL D.O.T. SPECIAL FORM CAPSULE 0.200" (5.08 mm) CAPSULE FIGURE 67-A 3204 CAPSULE (XFB-3) FIGURE 67-B 3205 CAPSULE WELD CAPSULE (5.08 mm) 0.500" (12.7 mm) Be WINDOW 0.010" (0.25 mm) FIGURE 67-C 3215 CAPSULE (XFB-5) Some important features of the 3204, 3205 and 3215 (XFB-5) capsule are: Beryllium windows provide excellent transmission for energies below 50 kev. Sealing by high temperature brazing provides reliability and safety by having an all-m e t a l c o n s t r u c t i o n. The monolithic construction of the active element provides an additional safety factor in case of window failure and assures that the radioactivity does not shift once the source has been installed. The 3204 and the 3205 (XFB-3) capsules have been tested and registered in accordance with ANSI classifications for sealed gauging sources. Sources are also classified with the D.O.T. as Special Form. All sources are suitable for use under high vacuum conditions.

14 Iso Catalog /23/99 9:21 PM Page 68 LO W EN E R G Y X - RA Y AN D GA M M A RA Y SO U R C E S Point Sources (PHI) C o b a l t-57 I r o n-5 5 Half-life: 272 d Half-life: 2.74 y Photon energies (kev): Photon energies (kev): 14 (9.54%), 122 (85.5%), (10.7%), (27.3%) Mn K x-r a y s 6-7 (54.7%) Fe K x-rays C a d m i u m-1 09 Half-life: 1.27 y Photon energies (kev): 88 (3.6% from Ag-109m daughter), (99.8%) Ag K x- r a y s Active element: Elemental iron plated on (0.127 mm) thick nickel substrate. Accelerator grade Fe-55 may be available. Contact Technical Customer Service for more information. Photon output: Approximately 8.04 x 10 5 p h o t o n s / s / s t e r a d i a n per mci. Contained activity is supplied as a nominal value ±15%. C A T A L O G A C T I V I T Y A C T I V I T Y N U M B E R ( m C i ) ( M B q ) P H I P H I P H I P H I P H I P H I P H I * P H I * P H I * P H I * Active Diameter: (5.00 mm) Capsule type: 3204 * Contained activity. Self absorption will decrease the output activity. The transmission through the beryllium window is 88% Active element: Elemental cobalt plated on (0.127 mm) thick nickel substrate or incorporated into a ceramic element. R a d i o p u r i t y : 99% (Co-56 and Co-58 are <0.2% at the time of shipment). Please contact Technical Customer Service for information on a specific lot. Photon output: Approximately 2.5 x 10 6 (122 and 136 kev) photons/s/steradian per mci. Contained activity is supplied as a nominal value ±15%. C A T A L O G A C T I V I T Y A C T I V I T Y N U M B E R ( m C i ) ( M B q ) P H I P H I P H I P H I P H I P H I P H I P H I P H I P H I P H I P H I L O R O R Capsule Type: 3201 Active Diameter: (6.35 mm) Capsule type: 3204 Active Diameter 0.197" (5.0 mm) Active elements: Elemental cadmium plated on (0.127 mm) thick silver substrate or deposited on a ceramic matrix. Radiopurity: 99% (The emissions greater than 100 kev are approximately 0.2% of the 88 kev emissions. These impurities are from Zn-65, Rh-102, Cd 115m and Cd-113m). Contact Technical Customer Service for additional information. Photon output: Approximately 2.5 x kev photons/s/stera dian per mci. Contained activity is supplied as a nominal value ±15%. C A T A L O G A C T I V I T Y A C T I V I T Y N U M B E R ( m C i ) ( M B q ) P H I P H I P H I P H I P H I P H I P H I P H I P H I P H I Active Diameter: (5.00 mm) Capsule type: 3204 or 3205

15 Iso Catalog /23/99 9:21 PM Page 69 LO W EN E R G Y X - RA Y AN D GA M M A RA Y SO U R C E S Point Sources (PHI) G a d o l i n i u m Half-life: 242 d Photon energies (kev): 97 (27.6%), 103 (19.6%), (120%) Eu K x-r a y s ) Active element: Gadolinium oxide bound in a ceramic matrix Radiopurity: >99% (Eu-152<0.01%) Photon output: Approximately 7 x 10 5 p h o t o ns /s/steradian per mci (97 kev). Contained activity is supplied as a nominal value ±15%. C A T A L O G A C T I V I T Y A C T I V I T Y N U M B E R ( m C i ) ( M B q ) P H I P H I P H I P H I P H I P H I L O R O R Active Diameter: (5.33mm) Capsule type: 3201 Other nuclides such as Iodine-125 are available on request. E u r o p i u m Half-life: 4.96 y Photon energies (kev): 86.5 (34%), (20.6%), Gd K x-rays kev (25.3%) Active Element: Europium oxide in ceramic m a t r i x Radiopurity: 99% Photon output: ~7 x 10 6 photons/s/steradian per mci at 87 kev. A m e r i c i u m Half-life: 433 y Photon energies (kev): 60 (36%), >100 (0.0306%), (39.5%) Np L x-r a y s Active element: Americium oxide bound in ceramic or aluminum matrix Radiopurity: >99% Photon output: Approximately 8 x 10 5 p h o t o ns/s/steradian per mci (60 kev) unless otherwise specified. Contained activity is supplied as a nominal value ±15%. A m-241 is normally supplied in the 3201 capsule for applications requiring only the 60 kev gamma emission. For situations requiring the low energy x-r a y s, Am-241 is available in the 3204 capsule fitted with a 0.01 (0.254 mm) beryllium window. Because of self-absorption only low activities are useful in this configuration. C A T A L O G A C T I V I T Y A C T I V I T Y N U M B E R ( m C i ) ( M B q ) P H I P H I P H I P H I P H I P H I P H I Active diameter: (5.33 mm) Capsule type: 3201 C u r i u m-244 Half-life: 18.1 y Photon energies (kev): (approximately 9%) Pu L x-rays Active element: Curium oxide plated on (0.127 mm) thick platinum-clad nickel substrate or deposited onto a ceramic matrix. Radiopurity: <0.005% photons >100 kev Photon output: Approximately 1 x 10 6 p h o t o ns /s/steradian per mci (18 kev). Contained activity is supplied as a nominal value ±15%. C A T A L O G A C T I V I T Y A C T I V I T Y N U M B E R ( m C i ) ( M B q ) P H I P H I P H I Active Diameter: (5.00 mm) Capsule type: 3204 C A T A L O G A C T I V I T Y A C T I V I T Y N U M B E R ( m C i ) ( M B q ) P H I P H I P H I Active Diameter: (5.33 mm) Capsule type: 3201

16 Iso Catalog /23/99 9:21 PM Page 70 AN N U L A R SO U R C E SY S T E M S FO R X - RA Y FL U O R E S C E N C E (XRF) SP E C T R O S C O P Y (AN SERIES) The annular radionuclide sources assemblies provide a convenient form of low energy monochromatic x-rays for use with modern analytic spectroscopy systems. The annular geometry provides the most efficient method of fluorescing the sample, and compensating for irregularities in sample positions and uniformity. Each model has been designed to give optimum performance as well as freedom from secondary radiations arising from materials of construction. This is accomplished by using selected shielding and filter materials built into the assembly. All assembly designs have been tested in accordance with ANSI N and have been assigned classification C A m e r i c i u m-241 sources are also registered as D.O.T. Special Form as defined in 49CFR This allows shipment in simple, non-returnable cardboard containers, a distinct advantage when the source is part of a more complex system. Contained activity for all XRF sources is supplied as a nominal value ±15%. Two basic types of assemblies are available: AN Reloads (AN-REL) New sources will be loaded into customersupplied source assemblies and the depleted sources will be accepted for disposal. To reduce customer downtime, Isotope Products will request delivery of the depleted source assembly when the replacement sources have been manufactured. In the case of Am-241/Cd-109 Composite Sources the reload service includes a soak test of the existing Am-241 source. 2 50" (63.5 mm) COVER PREFFERED P R E F F E R E D N U C L I D E ELEMENT RANGES ELEMENT RANGES K - L I N E S L - L I N E S C d C h r o m i u m - M o l y b d e n u m T e r b i u m - U r a n i u m C o - 57 T i t a n i u m - S e l e n i u m, L a n t h a n u m - L e a d H o l m i u m - U r a n i u m A m Z i n c - N e o d y m i u m H a f n i u m - U r a n i u m F e S i l i c o n - V a n a d i u m N i o b i u m - C e r i u m C m T i t a n i u m - S e l e n i u m L a n t h a n u m - L e a d G d I r o n - T e l l u r i u m S a m a r i u m - L e a d E r b i u m - L e a d E u I r o n - T e l l u r i u m C e r i u m - L e a d S a m a r i u m - L e a d LEAD INSERT RETAINING RING Series AN provides for direct irradiation of the sample. Series ANT is a source-target system 1.375" (34.9 mm) 1.125" (28.6 mm) TORUS CELL PLATE AN-109 ASSEMBLY BODY AN Series Sources (AN) The active elements of Fe-55, Cd-109 and C o-57 are prepared by electrodeposition of the metal on an annular substrate and sealed with a bonded beryllium window. The active elements of Am-241 and Eu-155 are prepared as a series of ceramic disks or aluminum pellets arranged in an annular configuration. All AN sources are designed to be furnished in the series AND holders described below. Geometries using tungsten shielding are available. Arrangements can be made to fabricate holders to custom designs. WASHER FIGURE 70-A AN SOURCE IN AND HOLDER

17 Iso Catalog /23/99 9:21 PM Page 71 AN N U L A R SO U R C E SY S T E M S FO R X - RA Y FL U O R E S C E N C E (XRF) SP E C T R O S C O P Y I r o n-5 5 H a l f-life: 2.73 y Photon energies (kev): (27.3%) Mn K x-r a y s The active element consists of elemental iron electroplated and diffusion bonded onto a (0.254 mm) thick nickel annulus covered with a (0.254 mm) annular beryllium window. For transport and storage protection Isotope Products recommends purchase of the AND-3 holder. Accelerator-produced Fe-55 [1,000-2, mci/mg iron (37-74 GBq/mg iron)] is sometimes available. Call the Sales Department for more information and availability. CAPSULE ACTIVE FOIL " (7.94 mm) ANSI SPECIAL FORM MATERIAL Be WINDOW 2.020" (51.3 mm) 0.375" (9.53 mm) 99% PURE TIN LINER FIGURE 71-A AN " (30 mm) 0.375" (9.53 mm) BERYLLIUM WINDOW RING E.B.WELD ANSI C A T A L O G A C T I V I T Y A C T I V I T Y N U M B E R ( m C i ) ( M B q ) A N A N " (2.67 mm) 12 S FIGURE 71-B AN-241 A N A N A N ANSI " (38.1 mm) MAX 0.5" (12.7 mm) 0.010" (0.254 mm) BERYILLUM COVER BONDED TO FOIL A N C o b a l t " (0.508 mm) RADIOACTIVE MATERIAL BONDED TO FOIL 0.01" (0.254 mm) NICKEL FOIL H a l f-life: 272 d FIGURE 71-C AN-55 Photon energies (kev): 14 (9.54%), 122 (85.5%), (10.7%), 6-7 (54.7%) Fe K x-r a y s The active element (option 1) consists of metallic cobalt electroplated and diffusion bonded onto a nickel annulus and covered with a (0.254 mm) beryllium window or (option 2) the active element consists of a series of ceramic or aluminum disks approximately, (3.25 mm) in diameter, arranged in an annular configuration and sealed in a welded stainless steel capsule. C A T A L O G A C T I V I T Y A C T I V I T Y N U M B E R ( m C i ) ( M B q ) A N A N A N A N A N A N Additional nuclides, including Cm-244, Gd-1 5 3, and I-125, are available on request.

18 Iso Catalog /23/99 9:21 PM Page 72 AN N U L A R SO U R C E SY S T E M S FO R X - RA Y FL U O R E S C E N C E (XRF) SP E C T R O S C O P Y C a d m i u m Half-life: 1.27 years Photon energies (kev): 88 (3.6% from Ag-109 daughter), (99.8%) Ag K x-rays The active element consists of metallic cadmium electroplated on a silver annulus and covered with a bonded 0.01 (0.254 mm) beryllium window. C A T A L O G A C T I V I T Y A C T I V I T Y N U M B E R ( m C i ) ( M B q ) A N A N A N A N A N A N A N A N A N A m e r i c i u m H a l f-life: 433 y Photon energies (kev): 60 (36%), (39.5%) Np L x-rays The active element consists of a series of ceramic or aluminum disks approximately, (3.25 mm) in diameter, arranged in an annular configuration and sealed in a welded stainless steel capsule. C A T A L O G A C T I V I T Y A C T I V I T Y N U M B E R ( m C i ) ( M B q ) A N A N A N A N A N Source Holder Assembly (AND Series) AND holders provide a convenient and safe method for storing and using the AN series sources for direct irradiation of a target specimen Specifications: Central hole diameter: (9.53 mm Overall diameter: (63.5 mm Inside diameter: (50.8 mm Active annulus diameter: (19.1 mm C A T A L O G S H I E L D I N G R E C O M M E N D E D N U M B E R M A T E R I A L N U C L I D E S A N D - 1 L e a d Am-241, Co-57, Gd-153, Eu-155 A N D - 2 T i n Cd-109, I-125 A N D - 3 N i c k e l Fe-55 only plated brass S P E C I M E N SOURC DETECTOR FIGURE 72-B SERIES AND HOLDER A N D - 3 A N D - 1 A N D - 2 FIGURE 72-A ANNULAR SOURCE HOLDER ASSEMBLIES To place an order: Phone FAX Please include the catalog number, the capsule or configuration number, the nuclide, the activity and any NIST traceability requirements.

19 Iso Catalog /23/99 9:21 PM Page 73 AN N U L A R SO U R C E SY S T E M S FO R X - RA Y FL U O R E S C E N C E (XRF) SP E C T R O S C O P Y ANT Series The ANT Series is a source target system designed primarily for use with Am-241 and a variety of replaceable targets. ANT sources are useful for exciting the characteristic x-rays of a target material. The active element is an array of six equally spaced 3201 capsules placed in a shielded assembly. Specifications: Central hole diameter: Overall diameter: Inside diameter: Shielding material: (9.53 mm) 2.50 (63.5 mm) 2.00 (50.8 mm) l e a d The source-holder assembly includes a 50 or 100 mci (1.85 or 3.7 GBq) Am-241 source. Targets are available as a separate option. Contained activity is supplied as a nominal value ± 1 5 %. Other nuclides are available on request. ANT Targets The TR series of x-ray fluorescence targets is designed to be used with the Series ANT annular source-holder assembly. The target consists of an annular aluminum cup containing the target element in the form of a pure metallic foil, powdered metal, or metal oxide dispersed in a pure acrylic binder. All materials used are of the highest commercially available purity. The targets listed in the table include elements from Z=26 through Z=69, and are suitable for use with Am-241 and Cd-109 excitation sources. Other target elements are available on r e q u e s t. SOURCE TARGET S P E C I M E N DETECTOR FIGURE 73-A SERIES ANT HOLDER MODEL E L E M E N T CHEMICAL N U M B E R F O R M T R - 4 B e r y l l i u m F o i l TR-5 B o r o n P o w d e r T R - 6 P o l y p r o p y l e n e S h e e t T R - 6 A G r a p h i t e F o i l T R - 7 P o l y i m i d e S h e e t T R - 8 M y l a r S h e e t T R - 9 T e f l o n S h e e t T R M a g n e s i u m P o w d e r T R - 3 A l u m i n u m F o i l T R S i l i c o n P o w d e r T R Phosphorus Nitrate P o w d e r T R S u l f u r P o w d e r T R Polyvinyl Chloride S h e e t T R Calcium Carbonate P o w d e r T R S c a n d i u m P o w d e r T R T i t a n i u m F o i l T R V a n a d i u m F o i l T R C h r o m i u m P o w d e r T R M a n g a n e s e P o w d e r T R I r o n F o i l T R C o b a l t F o i l T R N i c k e l P o w d e r T R C o p p e r F o i l T R Z i n c F o i l T R G a l l i u m P o w d e r T R G e r m a n i u m P o w d e r T R A r s e n i c P o w d e r T R S e l e n i u m P o w d e r T R Z i r c o n i u m F o i l T R N i o b i u m F o i l T R M o l y b d e n u m M e t a l T R R u t h e n i u m P o w d e r T R R h o d i u m P o w d e r MODEL E L E M E N T CHEMICAL N U M B E R F O R M T R P a l l a d i u m F o i l T R S i l v e r F o i l T R C a d m i u m P o w d e r T R I n d i u m F o i l T R T i n F o i l T R A n t i m o n y P o w d e r T R T e l l u r i u m P o w d e r T R B a r i u m P o w d e r T R Lanthanum P o w d e r T R C e r i u m P o w d e r T R P r a s e o d y m i u m P o w d e r T R N e o d y m i u m P o w d e r T R S a m a r i u m P o w d e r T R E u r o p i u m P o w d e r TR-64 G a d o l i n i u m P o w d e r T R T e r b i u m P o w d e r T R D y s p r o s i u m P o w d e r T R H o l m i u m P o w d e r T R E r b i u m P o w d e r T R T h u l i u m P o w d e r T R Y t t e r b i u m P o w d e r T R L u t e t i u m P o w d e r T R H a f n i u m F o i l T R T a n t a l u m F o i l T R T u n g s t e n F o i l T R R h e n i u m P o w d e r T R I r i d i u m P o w d e r T R P l a t i n u m P o w d e r T R G o l d P o w d e r T R M e r c u r y P o w d e r T R T h a l l i u m P o w d e r T R L e a d P o w d e r

20 Iso Catalog /23/99 9:21 PM Page 74 SP E C I A L PU R P O S E RA D I O G R A P H Y SO U R C E S Y t t e r b i u m-169 (R-169) The low energy gamma and x-ray spectrum of Y b-169 makes this nuclide particularly suitable for radiographic examination of thin weldments and mechanical assemblies. The unique gamma spectrum of Yb-169 resembles the x-ray envelope spectrum from a low-to-intermediate energy x-ray tube. The active element consists of ytterbium oxide. This is encapsulated in a welded aluminum capsule diameter x long (4.06 mm x 8.38 mm), sufficiently small to be accommodated in most secondary capsules or radiography cameras. The active area is 0.60 x (1.52 mm x 4.57 mm). Contained activity is supplied as a nominal value ±20%. H a l f - L i f e : 32.0 d Principal gammas (kev): 63.1 (437%), 110 (17.4%), 130 (11.1%), 177 (21.5%), 198 (34.9%), 308 (10.8%), Tm K x-rays: kev ( % ) CATALOG ACTIVITY ACTIVITY N U M B E R ( C i ) ( G B q ) R Up to 0.1 Up to 3.7 R R R Selenium-75 (R-75) This nuclide has a gamma spectrum predominantly in the kev range, making it useful for specialized radiography and gauging applications. The active element is a x (5.00 x 5.00 mm) cylinder of metallic selenium in an aluminum capsule 0.5 long x diameter (12.7 mm x 8.00 mm). Contained activity is sup plied as a nominal value ±20%. Higher activities and special encapsulations are available. H a l f - l i f e : 120 d ALUMINUM CAPSULE Principal gammas (kev): 121 (17.3%), 136 (59.0%), 265 (59.2%), 280 (25.2%), (11.6%), As K x-rays: kev (55.6%) CATALOG ACTIVITY ACTIVITY N U M B E R ( m C i ) ( G B q ) 0.164" (4.17 mm) 0.322" (8.18 mm) R R FIGURE 74-A 3603 Capsule (Yb-169) OUTER CAPSULE 1100 ALUMINUM 0.500" (12.7 mm) 0.315" (8.0 mm) PURE Se-75 METAL INNER OUTER WELD FIGURE 74-B 3616 Capsule (Se-75)

21 Iso Catalog /23/99 9:21 PM Page 75 SP E C I A L PU R P O S E RA D I O G R A P H Y SO U R C E S 3805 Capsule (formerly SK-201) The Yb-169 and Se-75 sources listed on the previous page are available welded into the 3805 capsule (formerly SK-201). This is a stainless steel capsule diameter x 1.95 long (12.5 mm x 49.5 mm) with an eyelet at the welded end. Contained activity is supplied as a nominal value ±20%. ACTIVE ELEMENT 1.950" (49.5 mm) WELD Model R : Yb " (12.5 mm) Model R : Se-75 CAPSULE FIGURE 75-A 3805 CAPSULE (FORMERLY SK-201) C A P S U L E C A P S U L E 3805 CAPSULE FIGURE 75-B SPECIAL PURPOSE RADIOGRAPHY SOURCES To place an order: Phone FAX Please include the catalog number, the capsule or configuration number, the nuclide, the activity and any NIST traceability requirements.

22 Iso Catalog /23/99 9:21 PM Page 76 HI G H A C T I V I T Y GA M M A RA D I A T I O N SO U R C E S PHIS SERIES AM E R I C I U M A p p l i c a t i o n : These sources are typically used in industrial thickness gauges. D e s c r i p t i o n : Americium-241 homogeneously sintered in ceramic pellet, encapsulated in a TIG welded single stainless steel special form capsule. nominal nominal external active height window ISO 2919 activity activity diameter diameter thickness classification A B C D capsule GBq mci mm mm mm mm C C C C E E H a l f - l i f e : 433 years 31-4 Photon energy: E = 59.5 kev A p p l i c a t i o n : Sources are used for applications in industrial gauging, e.g. fill level inspection. D e s c r i p t i o n : Americium-241 sintered in ceramic pellet, encapsulated in a TIG welded single stainless steel special form capsule. nominal nominal external active window encapsu- ISO 2919 activity activity diameter diameter thickness lation classification A B capsule GBq mci mm mm mm single C single C H a l f - l i f e : 433 years Photon energy: E = 59.5 kev 31-5

23 Iso Catalog /23/99 9:21 PM Page 77 HI G H A C T I V I T Y GA M M A RA D I A T I O N SO U R C E S (c o n t i n u e d) HEGS SERIES CO B A L T- 6 0 A p p l i c a t i o n : Sources are used for various applications in industrial gauging. D e s c r i p t i o n : A nickeled radioactive Cobalt-60 pellet is encapsulated in a TIG welded, double walled, stainless steel capsule. The inner capsule has a wall thickness of 0.4 mm on all sides. They are housed in a TIG welded stainless steel capsule of wall thickness 1.15mm. nominal nominal external active window encapsu- ISO 2919 activity activity diameter diameter thickness lation classification capsule GBq mci mm mm mm A double C A double C A double C A double C A3028 A3029 Half-life: 5.27 years Photon energy: E 1 = 1.33 MeV E 2 = 1.17 MeV

24 Iso Catalog /23/99 9:21 PM Page 78 HI G H A C T I V I T Y GA M M A RA D I A T I O N SO U R C E S (c o n t i n u e d) HEGS SERIES CE S I U M A p p l i c a t i o n : Sources can be used for thickness, level and density gauges and various other applications in industrial gauging. D e s c r i p t i o n : The source contains Cs-137 in an almost insoluble and abrasion resistant form. The ceramic activity carriers are sealed in stainless steel capsules with a wall thickness of 0.4mm on all sides. The primary capsules are sealed by argonarc welding. They are housed in a TIG welded second stainless steel capsule. nominal nominal external active window encapsu- ISO 2919 activity activity diameter diameter thickness lation classification capsule GBq mci mm mm mm single single double C double C Half-life: 30.2 years Photon energy: E = 662 kev radioactive part : Ø4 x : Ø4 x 3 radioactive part : Ø4 x : Ø4 x 3 A p p l i c a t i o n : Sources can be used for thickness, level and density gauges and various other applications in industrial gauging. D e s c r i p t i o n : The source contains Cs-137 in an almost insoluble and abrasion resistant form. The ceramic activity carriers are sealed in stainless steel capsules with a wall thickness of 0.3 m m (wall) and 0.5 mm (ends). The primary capsules are sealed by TIG welding. They are housed in a TIG welded second stainless steel capsule. nominal nominal external active window encapsu- ISO 2919 activity activity diameter diameter thickness lation classification capsule GBq mci mm mm mm double C double C Half-life: 30.2 years Photon energy: E = 662 kev

25 Iso Catalog /23/99 9:21 PM Page 79 HI G H A C T I V I T Y GA M M A RA D I A T I O N SO U R C E S (c o n t i n u e d) HEGS SERIES CE S I U M A p p l i c a t i o n : The sources can be used for thickness, level and density gauges and various other industrial a p p l i c a t i o n s. D e s c r i p t i o n : The source contains Cs-137 in an almost insoluble and abrasion resistant form. The ceramic activity carriers are sealed in a TIG welded stainless steel capsule with a wall thickness of 0.4 mm. They are housed in a second TIG welded stainless steel capsule. nominal nominal external active window encapsu- ISO 2919 activity activity diameter diameter thickness ulation classification capsule GBq mci mm mm mm single C A double C A double C A double C A double C A3028 A A A3029 Half-life: years Photon energy: 662 kev

26 Iso Catalog /23/99 9:21 PM Page 80 HI G H A C T I V I T Y GA M M A RA D I A T I O N SO U R C E S (c o n t i n u e d) HEGS SERIES CE S I U M A p p l i c a t i o n : Sources can be used for thickness, level and density gauges and various other applications in industrial gauging. D e s c r i p t i o n : The source contains Cs-137 in an almost insoluble and abrasion resistant form. The ceramic activity carriers are sealed in stainless steel capsules. The primary capsules are sealed by argonarc welding. They are housed in a TIG welded stainless steel capsule. nominal nominal external active window encapsu- ISO 2919 activity activity diameter diameter thickness lation classification capsule GBq mci mm mm mm double C d o u b l e C Half-life: 30.2 years Photon energy: 662 kev

27 Iso Catalog /23/99 9:21 PM Page 81 BE T A RA D I A T I O N SO U R C E S B F I S S E R I E S KR Y P T O N- 8 5 A p p l i c a t i o n : The sources are used for applications in industrial gauging. D e s c r i p t i o n : Krypton-85 gas, hermetically sealed in a nickel t u b e. nominal nominal overall active wall encapsuactivity activity length length thickness lation A B Ni / SS capsule GBq mci mm mm µm single single single single single Line sources with length and nominal activity differing from the types given in the figure on the right available on request. Half-life: 10.7 years ß-energy: 670 kev Ni: Ø 3.7mm SS: Ø 5.1mm 33-7

28 Iso Catalog /23/99 9:21 PM Page 82 BE T A R A D I A T I O N SO U R C E S (c o n t i n u e d) BFIS SERIES KR Y P T O N- 8 5 A p p l i c a t i o n : The sources are used for applications in industrial and environmental gauging. D e s c r i p t i o n : Krypton-85 gas, hermetically sealed in a cylindrical single stainless steel or titanium capsule with a stainless steel or titanium window respectively. The capsule is sealed by electric arc welding. Two holes can be used for fixing the s o u r c e. capsule GBq mci mm mm mm µm single C single C single C Half-life: 10.7 years ß-energy: 670 kev nominal nominal external active height window encapsu- ISO 2919 activity activity diameter diameter thickness lation classification A p p l i c a t i o n : The sources can be used for applications in industrial and environmental gauging. D e s c r i p t i o n : Krypton-85 gas, hermetically sealed in a cylindrical single stainless steel capsule with a stainless steel window respectively. The capsule is sealed by electric arc welding. nominal nominal external active window encapsu- ISO 2919 activity activity diameter diameter thickness lation classification capsule GBq mci mm mm µm single C single C Half-life: 10.7 years ß-energy: 670 kev

29 Iso Catalog /23/99 9:21 PM Page 83 BE T A RA D I A T I O N SO U R C E S (c o n t i n u e d) B F I S S E R I E S KR Y P T O N- 8 5 A p p l i c a t i o n : The source is used for applications in environmental gauging. D e s c r i p t i o n : Krypton-85 gas, hermetically sealed in a cylindrical single titanium capsule with two brazed titanium windows. The source is mounted in a chromium-plated brass adapter ring. nominal nominal external active window encapsu- ISO 2919 activity activity diameter diameter thickness lation classification capsule GBq mci mm mm µm single C Half-life: 10.7 years ß-energy: 670 kev B F I S S E R I E S RU T H E N I U M A p p l i c a t i o n : Sources can be used for thickness gauges and for calibration or reference, and other scientific a p p l i c a t i o n s. D e s c r i p t i o n : The source is an Aluminum capsule containing R u t h e n i um-106, electrodeposited on a silver target, further sealed in silver foil. The rear side of the source has three tapped holes and one annular groove in the external wall of the caps u l e. nominal nominal external active window Thread ISO 2919 activity activity diameter diameter diameter thickness (metric) classification A B C capsule MBq mci mm mm mm mm m M 2 C M3 C M 3 C Half-life: 369 days ß-energy: 3.54 MeV 12-2

30 Iso Catalog /23/99 9:21 PM Page 84 RESERV ED

31 Iso Catalog /23/99 9:21 PM Page 85 NE U T R O N SO U R C E S A N S S E R I E S AM E R I C I U M / BE R Y L L I U M A p p l i c a t i o n : Neutron sources are used in geological prospecting, moisture gauging, activation analysis, nuclear research, and for applications in oil well logging. D e s c r i p t i o n : Homogeneous mixture of Americium-241 oxide with Beryllium metal, encapsulated in a TIG welded double stainless steel special form c a p s u l e. nominal nominal external overall ISO 2919 IAEA activity activity diameter length classification Special Form capsule GBq mci mm mm C D/0067/S C D/0059/S C D/0068/S C D/0064/S C D/0065/S Half-life: years Neutron emission: 2.2 x 10 6 n/s per Ci

Gamma and X-Ray Standards

Gamma and X-Ray Standards Gamma and X-Ray Standards A wide range of gamma and x-ray standards for research and educational use are available in the energy range of 5.9 to 2614 kev. Many nuclides are available up to 100 µci (3.7

More information

1 of 16 1/28/2014 2:35 PM. Search

1 of 16 1/28/2014 2:35 PM. Search 1 of 16 1/28/2014 2:35 PM Home Product Menu Geiger Counters Motion Control Servo Motor Index Biofeedback Devices Speech Recognition Servobotics PIC Microcontroller Holography Nitinol Products Electronic

More information

PRODUCTS FOR EDUCATION AND TRAINING

PRODUCTS FOR EDUCATION AND TRAINING PRODUCTS FOR EDUCATION AND TRAINING This section gives detailed information about products to support training in radiation protection, applications of radioactivity and handling radioactive materials.

More information

Multi Analyte Custom Grade Solution. Calcium, Iron, Potassium,

Multi Analyte Custom Grade Solution. Calcium, Iron, Potassium, 1.0 ACCREDITATION / REGISTRATION INORGANIC VENTURES is accredited to ISO Guide 34, "General Requirements for the Competence of Reference Material Producers" and ISO/IEC 17025, "General Requirements for

More information

Multi Analyte Custom Grade Solution. Aluminum, Potassium, Magnesium, ANALYTE CERTIFIED VALUE ANALYTE CERTIFIED VALUE

Multi Analyte Custom Grade Solution. Aluminum, Potassium, Magnesium, ANALYTE CERTIFIED VALUE ANALYTE CERTIFIED VALUE 1.0 ACCREDITATION / REGISTRATION INORGANIC VENTURES is accredited to ISO Guide 34, "General Requirements for the Competence of Reference Material Producers" and ISO/IEC 17025, "General Requirements for

More information

Survey Meter OD-01 Address: Phone: Fax: URL:

Survey Meter OD-01 Address: Phone: Fax:   URL: Survey Meter OD-01 Dose meter and dose rate meter for the measurement of the ambient dose and dose rate equivalent H*(10), dh*(10)/dt and the directional dose and dose rate equivalent H'(0.07), dh'(0.07)/dt

More information

MARINELLI BEAKERS CATALOG

MARINELLI BEAKERS CATALOG GA-MA & ASSOCIATES, INC. Specialty Products for the Radiochemistry Laboratory MARINELLI BEAKERS CATALOG Snap-on Lid Design Gas Marinelli Beaker Threaded Lid Design Tel: 352.687-8840 404 Cypress Road Fax:

More information

ANALYSIS CERTIFICATE OF

ANALYSIS CERTIFICATE OF CERTIFICATE OF ANALYSIS 300 Technology Drive Christiansburg, VA 24073. USA inorganicventures.com tel: 800.669.6799. 540.585.3030 fax: 540.585.3012 info@inorganicventures.com 1.0 INORGANIC VENTURES is an

More information

WIDE AREA REFERENCE SOURCES

WIDE AREA REFERENCE SOURCES WIDE AREA REFERENCE SOURCES This section contains details of sealed sources for calibrating surface contamination monitors. A wide range of products with different dimensions and radionuclides is available.

More information

6. Radioactive Sources and IAEA Course Catalog

6. Radioactive Sources and IAEA Course Catalog 6. Radioactive Sources and IAEA Course Catalog IAEA Guidance #5: Identification of Radioactive Sources and Devices Aids non-specialist individuals and organizations in initial identification of radioactive

More information

ICP/MS Multi-Element Standards

ICP/MS Multi-Element Standards Standards Ultra Pure Matrix Special Packaging Traceability to National Reference Materials AccuStandard s ICP/MS Standards are formulated to meet the needs of this very special instrument. As matrix effect

More information

Dose Rate Levels around Industrial Gamma Sources

Dose Rate Levels around Industrial Gamma Sources Dose Rate Levels around Industrial Gamma Sources Héctor René Vega-Carrillo *, Ricardo Rodríguez-Juárez, Eduardo Manzanares- Acuña, Rubén Hernández-Villasana, Jaime Ramírez-González Universidad Autónoma

More information

RADIOACTIVITY. 95 Alpha Particle Solution Standards. 96 Beta Particle and Electron Capture Solution Standards. 97 Gamma Point Source

RADIOACTIVITY. 95 Alpha Particle Solution Standards. 96 Beta Particle and Electron Capture Solution Standards. 97 Gamma Point Source 95 Alpha Particle Solution Standards 96 Beta Particle and Electron Capture Solution Standards 97 Gamma Point Source 97 Radiopharmaceutical Standards 98 Beryllium Isotopic Ratio Standard 98 Radiocarbon

More information

Ion-Chamber Survey Meter OD-02

Ion-Chamber Survey Meter OD-02 Ion-Chamber Survey Meter OD-02 Dose and dose rate meter for measuring the ambient dose equivalent H*(10) and dose rate equivalent dh*(10)/dt as well as the directional dose equivalent H (0,07) and dose

More information

IAEA-SM-367/10/04/P SCREENING AND RADIOMETRIC MEASUREMENT OF ENVIRONMENTAL SWIPE SAMPLES

IAEA-SM-367/10/04/P SCREENING AND RADIOMETRIC MEASUREMENT OF ENVIRONMENTAL SWIPE SAMPLES IAEA-SM-367/10/04/P SCREENING AND RADIOMETRIC MEASUREMENT OF ENVIRONMENTAL SWIPE SAMPLES V. MAIOROV, A. CIURAPINSKI, W. RAAB and V. JANSTA Safeguards Analytical Laboratory, International Atomic Energy

More information

1.0 ACCREDITATION / REGISTRATION 2.0 PRODUCT DESCRIPTION 3.0 CERTIFIED VALUES AND UNCERTAINTIES. Assay Information:

1.0 ACCREDITATION / REGISTRATION 2.0 PRODUCT DESCRIPTION 3.0 CERTIFIED VALUES AND UNCERTAINTIES. Assay Information: 1.0 ACCREDITATION / REGISTRATION INORGANIC VENTURES is accredited to ISO Guide 34, "General Requirements for the Competence of Reference Material Producers" and ISO/IEC 17025, "General Requirements for

More information

SODIUM PERTECHNETATE ( 99m Tc) INJECTION (FISSION): Revised Final text for addition to The International Pharmacopoeia (January September 2009)

SODIUM PERTECHNETATE ( 99m Tc) INJECTION (FISSION): Revised Final text for addition to The International Pharmacopoeia (January September 2009) September 2009 RESTRICTED SODIUM PERTECHNETATE ( 99m Tc) INJECTION (FISSION): Revised Final text for addition to The International Pharmacopoeia (January September 2009) [Note from the Secretariat: This

More information

IdentiFINDER Digital Hand Held Spectrometer & Dose Rate Meter for Portable Applications

IdentiFINDER Digital Hand Held Spectrometer & Dose Rate Meter for Portable Applications fire IdentiFINDER Digital Hand Held Spectrometer & The world s smallest spectrometer and dose rate meter designed for portable applications. safety security identifinder - CH (yellow) CZT and neutron detector

More information

RADIONUCLIDE INFORMATION

RADIONUCLIDE INFORMATION RADIONUCLIDE INFORMATION Below are some physical properties and practical handling information for radionuclides most commonly used in the research environment. Contact the RSO for additional information

More information

OXEA - Online Elemental Analyzer

OXEA - Online Elemental Analyzer 02 25 08 OXEA - Online Elemental Analyzer OXEA (Online X-ray Elemental Analyzer) is based on the X-ray fluorescence technology (XRF) which is well known in the laboratory field. With the aid of a patented

More information

Planning and preparation approaches for non-nuclear waste disposal

Planning and preparation approaches for non-nuclear waste disposal Planning and preparation approaches for non-nuclear waste disposal Lucia Sarchiapone Laboratori Nazionali di Legnaro (Pd) Istituto Nazionale di Fisica Nucleare INFN Lucia.Sarchiapone@lnl.infn.it +39 049

More information

GM Pancake Probe Victoreen Model D

GM Pancake Probe Victoreen Model D Radiation Safety RS GM Pancake Probe Victoreen Model 489-110D! All purpose GM Pancake Probe detects alpha, beta, gamma, and x-ray radiations! Used in nuclear medicine, diagnostic x-ray, and geological

More information

D) g. 2. In which pair do the particles have approximately the same mass?

D) g. 2. In which pair do the particles have approximately the same mass? 1. A student constructs a model for comparing the masses of subatomic particles. The student selects a small, metal sphere with a mass of gram to represent an electron. A sphere with which mass would be

More information

Sta-Saf. System. The. BSBsystems.com BSB.ie Visit our website for the most complete, up-to-date information. Reverse Buckling Technology

Sta-Saf. System. The. BSBsystems.com BSB.ie Visit our website for the most complete, up-to-date information. Reverse Buckling Technology Catalog # 77-4001 The Sta-Saf System Reverse Buckling Technology BSBsystems.com BSB.ie Visit our website for the most complete, up-to-date information. 1 Sta-Saf System The Sta-Saf System includes 11 reverse

More information

The first model was based only on the CANBERRA information which we. drawing. Canberra refused any other information.

The first model was based only on the CANBERRA information which we. drawing. Canberra refused any other information. Experimental and Monte Carlo determination of Gamma Spectrometry Efficiency Pavel Dryak, Petr Kovář Czech Metrology Institute February 2009 Leading motive of our testing The producer send the drawing after

More information

NORM Monitor-IS. Performance data

NORM Monitor-IS. Performance data NORM Monitor-IS Performance data Contents 1. Introduction... 3 Scintillator probe... 3 GM probe... 3 2. Energy response... 4 Scintillator probe gamma energy response... 4 Scintillator probe alpha/beta

More information

Specific Accreditation Criteria Calibration ISO/IEC Annex. Ionising radiation measurements

Specific Accreditation Criteria Calibration ISO/IEC Annex. Ionising radiation measurements Specific Accreditation Criteria Calibration ISO/IEC 17025 Annex Ionising radiation measurements January 2018 Copyright National Association of Testing Authorities, Australia 2014 This publication is protected

More information

ɣ-radiochromatography

ɣ-radiochromatography nuclear instruments Kapitel_y_Graphy.indd 1 19.08.09 10:27 n u c l e a r i n s t r u m e n t s Index HPLC-detectors TLC-detectors GABI* analog output GABI* digital output to PC minigita*, 1 trace scanner

More information

T h e rm i s t o r s

T h e rm i s t o r s Data Pack E Issued March 00 - T h e rm i s t o r s NTC thermistors The R S range of NTC thermistors includes standard tolerance negative temperature coefficient thermistors, a range of small close tolerance

More information

Methods to identify and locate spent radiation sources

Methods to identify and locate spent radiation sources IAEA-TECDOC-804 Methods to identify and locate spent radiation sources INTERNATIONAL ATOMIC ENERGY AGENCY The originating Section of this publication in the IAEA was: Waste Management Section International

More information

RADIATION SAFETY TRAINING SEALED SOURCES

RADIATION SAFETY TRAINING SEALED SOURCES RADIATION SAFETY TRAINING SEALED SOURCES PLEASE REFER TO THE RADIATION SAFETY HANDBOOK, PARTICULARLY THE SEALED SOURCES CHAPTER, AS A SUPPLEMENT TO THIS PACKET. Sealed source use at CU State and federal

More information

Single Analyte Mass Spec Solution ± µg/ml g/ml (measured at 20 ± 1 ºC) METHOD NIST SRM# SRM LOT#

Single Analyte Mass Spec Solution ± µg/ml g/ml (measured at 20 ± 1 ºC) METHOD NIST SRM# SRM LOT# 1.0 ACCREDITATION / REGISTRATION INORGANIC VENTURES is accredited to ISO Guide 34, "General Requirements for the Competence of Reference Material Producers" and ISO/IEC 17025, "General Requirements for

More information

Single Analyte Custom Grade Solution g/ml (measured at 20 ± 1 ºC) ICP Assay NIST SRM 3163 Lot Number:

Single Analyte Custom Grade Solution g/ml (measured at 20 ± 1 ºC) ICP Assay NIST SRM 3163 Lot Number: 1.0 ACCREDITATION / REGISTRATION INORGANIC VENTURES is accredited to ISO Guide 34, "General Requirements for the Competence of Reference Material Producers" and ISO/IEC 17025, "General Requirements for

More information

Radionuclides in Brachytherapy. Dr Irfan Ahmad Resident, Deptt of Radiation Oncology

Radionuclides in Brachytherapy. Dr Irfan Ahmad Resident, Deptt of Radiation Oncology Radionuclides in Brachytherapy Dr Irfan Ahmad Resident, Deptt of Radiation Oncology 1 Radionuclides Radium 226 Cobalt 60 Cesium 137 Iridium 192 Gold 198 Iodine 125 Palladium 103 Others Radon 222, Thulium

More information

ISOCS / LabSOCS. Calibration software for Gamma Spectroscopy

ISOCS / LabSOCS. Calibration software for Gamma Spectroscopy ISOCS / LabSOCS Calibration software for Gamma Spectroscopy Counts Setup Hardware Peak Shaping Parameters Rise Time Flat Top Pole-zero Number of Channels Signal Gain Setting up a detector for measurement

More information

Technical Note A Quantification and NIST Traceability of Micromatter Thin Film Standards for XRF Analysis. Version March 16, 2017

Technical Note A Quantification and NIST Traceability of Micromatter Thin Film Standards for XRF Analysis. Version March 16, 2017 MICROMATTER TECHNOLOGIES INC. #1-8333 130 th Street, Surrey, B.C. V3W 7X4, Canada Phone: +1.604.594.9720 or 1.866.966.2286 Fax: +1.604.594.9726 info@micromatter.com www.micromatter.com Technical Note 2015-01A

More information

RADIOLOGICAL CHARACTERIZATION Laboratory Procedures

RADIOLOGICAL CHARACTERIZATION Laboratory Procedures RADIOLOGICAL CHARACTERIZATION Laboratory Procedures LORNA JEAN H. PALAD Health Physics Research Unit Philippine Nuclear Research Institute Commonwealth Avenue, Quezon city Philippines 3-7 December 2007

More information

Overview of X-Ray Fluorescence Analysis

Overview of X-Ray Fluorescence Analysis Overview of X-Ray Fluorescence Analysis AMPTEK, INC., Bedford, MA 01730 Ph: +1 781 275 2242 Fax: +1 781 275 3470 sales@amptek.com 1 What is X-Ray Fluorescence (XRF)? A physical process: Emission of characteristic

More information

Field IT 50T Series Transmitters

Field IT 50T Series Transmitters Data Sheet SS/G/A_ Field IT 0T Series Transmitters gauge/absolute pressure transmitter Ranges: -00 to 0000kPa - to 00bar -. to 6000psi Base accuracy : 0.% (BFSL) Chemical Vapour Deposition (CVD) technology

More information

SL27C SL32C. ScreenLine. Technical Catalogue. english. double-glazed unit 27 mm 32 mm

SL27C SL32C. ScreenLine. Technical Catalogue. english. double-glazed unit 27 mm 32 mm VENETIAN SL27C SL32C BLIND english Technical Catalogue double-glazed unit 27 mm 32 mm dimensions technical specification SL27C SL32C System C C SL27C VENETIAN SL32C BLIND The venetian blinds SL27C and

More information

Single Analyte Custom Grade Solution ± 4 µg/ml g/ml (measured at 20 ± 1 ºC) Acidimetric NIST SRM 84L Lot Number: 84L

Single Analyte Custom Grade Solution ± 4 µg/ml g/ml (measured at 20 ± 1 ºC) Acidimetric NIST SRM 84L Lot Number: 84L 1.0 ACCREDITATION / REGISTRATION INORGANIC VENTURES is accredited to ISO Guide 34, "General Requirements for the Competence of Reference Material Producers" and ISO/IEC 17025, "General Requirements for

More information

Updated Contact Dose Rate Conversion Factors for Encapsulated Gamma Sources Including Secondary Electron Emission

Updated Contact Dose Rate Conversion Factors for Encapsulated Gamma Sources Including Secondary Electron Emission Updated Contact Dose Rate Conversion Factors for Encapsulated Gamma Sources Including Secondary Electron Emission Eric Heritage Supervisor: Dr. Ed Waller Outline Background Objectives PHITS Simulations

More information

Series 7500 Formed Metal Bellows Catalog 974C

Series 7500 Formed Metal Bellows Catalog 974C Series 00 Formed Metal Bellows Catalog C Innovators of the industry Bellows assemblies for safety valves, control valves, and regulators. When you look for a formed bellows which is reliable, has a long

More information

1 of 5 14/10/ :21

1 of 5 14/10/ :21 X-ray absorption s, characteristic X-ray lines... 4.2.1 Home About Table of Contents Advanced Search Copyright Feedback Privacy You are here: Chapter: 4 Atomic and nuclear physics Section: 4.2 Absorption

More information

1) Which electron would be most likely to emit x-ray electromagnetic energy?

1) Which electron would be most likely to emit x-ray electromagnetic energy? AP Chemistry Test (Chapter 7) Multiple Choice (40%) 1) Which electron would be most likely to emit x-ray electromagnetic energy? A) n = 1 n = 6 B) n = 2 n = 3 C) n = 6 n = 1 D) n = 3 n = 2 2) Which statement

More information

Peltier Application Note

Peltier Application Note Peltier Application Note Early 19th century scientists, Thomas Seebeck and Jean Peltier, first discovered the phenomena that are the basis for today s thermoelectric industry. Seebeck found that if you

More information

THE use of radioactive isotopes in medical institutions is growing continuously.

THE use of radioactive isotopes in medical institutions is growing continuously. EQUIPMENT FOR SAFE HANDLING OF RADIOACTIVE ISOTOPES OTTO GLASSER, PH.D. and BERNARD TAUTKINS Department of Biophysics THE use of radioactive isotopes in medical institutions is growing continuously. Shipments

More information

1.0 ACCREDITATION / REGISTRATION 2.0 PRODUCT DESCRIPTION 3.0 CERTIFIED VALUES AND UNCERTAINTIES. Assay Information:

1.0 ACCREDITATION / REGISTRATION 2.0 PRODUCT DESCRIPTION 3.0 CERTIFIED VALUES AND UNCERTAINTIES. Assay Information: 1.0 ACCREDITATION / REGISTRATION INORGANIC VENTURES is accredited to ISO Guide 34, "General Requirements for the Competence of Reference Material Producers" and ISO/IEC 17025, "General Requirements for

More information

Some nuclei are unstable Become stable by ejecting excess energy and often a particle in the process Types of radiation particle - particle

Some nuclei are unstable Become stable by ejecting excess energy and often a particle in the process Types of radiation particle - particle Radioactivity George Starkschall, Ph.D. Lecture Objectives Identify methods for making radioactive isotopes Recognize the various types of radioactive decay Interpret an energy level diagram for radioactive

More information

Geometric Considerations in the

Geometric Considerations in the Geometric Considerations in the Calibration of Germanium Detectors for Analytics, Inc. examines geometric questions involved in calibrating and counting filter papers using germanium detector, gamma-ray

More information

Fabrication of Radiation Sources for Educational Purposes from Chemical Fertilizers using Compressing and Forming Method

Fabrication of Radiation Sources for Educational Purposes from Chemical Fertilizers using Compressing and Forming Method Fabrication of Radiation Sources for Educational Purposes from Chemical Fertilizers using Compressing and Forming Method Takao Kawano National Institute for Fusion Science 322-6 Oroshi, Toki, Gifu 509-5292,Japan

More information

Surface-mounting Thermostats ATH Type Series

Surface-mounting Thermostats ATH Type Series Page 1/9 urface-mounting Thermostats ATH eries k enclosure protection IP 54 k tested to IN EN 14597 (replacing IN 3440) Brief description Thermostats control and monitor thermal processes. Instruments

More information

Leakage Tests for Am-241 Solid Sources Used for Liquid Xenon Detector Monitoring

Leakage Tests for Am-241 Solid Sources Used for Liquid Xenon Detector Monitoring Leakage Tests for Am-241 Solid Sources Used for Liquid Xenon Detector Monitoring S. Bazzarri, G. Cicoli, P. De Felice *, G. Rossi, F. Sedda ENEA C.R. Casaccia, C.P. 2400 I-00100 Rome - Italy. Abstract.

More information

Single-Element Standards for AAS

Single-Element Standards for AAS Single-Element Standards for AAS for AAS Flame Silver Ag in 2-5% HNO 3 Aluminium Al in 2-5% HCl Aluminium Al in 2-5% HNO 3 Arsenic As in 2-5% HCl Arsenic As in 2-5% HNO 3 Gold Au in 2-5% HCl Boron B in

More information

An extremity (wrist) dosemeter based on the Landauer InLight TM whole body dosemeter

An extremity (wrist) dosemeter based on the Landauer InLight TM whole body dosemeter An extremity (wrist) dosemeter based on the Landauer InLight TM whole body dosemeter Christopher A Perks *a and Stephane Faugoin a a LANDAUER EUROPE, 33 Avenue du General Leclerc, F-92266, Fontenay-aux-Roses

More information

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm DMP P Industrial Pressure Transmitter Process Connections With Flush Welded Stainless Steel accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 % FSO Nominal pressure from 0... 00 mbar up

More information

Advances in Field-Portable XRF

Advances in Field-Portable XRF Advances in Field-Portable XRF Volker Thomsen and Debbie Schatzlein Field-portable x-ray fluorescence (XRF) allows us to take the laboratory to the sample. The latest generation of such handheld x-ray

More information

1.0 ACCREDITATION / REGISTRATION 2.0 PRODUCT DESCRIPTION 3.0 CERTIFIED VALUES AND UNCERTAINTIES. Assay Information:

1.0 ACCREDITATION / REGISTRATION 2.0 PRODUCT DESCRIPTION 3.0 CERTIFIED VALUES AND UNCERTAINTIES. Assay Information: 1.0 ACCREDITATION / REGISTRATION INORGANIC VENTURES is accredited to ISO Guide 34, "General Requirements for the Competence of Reference Material Producers" and ISO/IEC 17025, "General Requirements for

More information

Single Analyte Custom Grade Solution ± 4 µg/ml g/ml (measured at 20 ± 1 ºC) EDTA NIST SRM 928 Lot Number: 928

Single Analyte Custom Grade Solution ± 4 µg/ml g/ml (measured at 20 ± 1 ºC) EDTA NIST SRM 928 Lot Number: 928 1.0 ACCREDITATION / REGISTRATION INORGANIC VENTURES is accredited to ISO Guide 34, "General Requirements for the Competence of Reference Material Producers" and ISO/IEC 17025, "General Requirements for

More information

User Manual. Stick-Style Water-Resistant Infrared Thermometer with 8:1 Distance-to-Sight Ratio. Model with NIST-Traceable Calibration

User Manual. Stick-Style Water-Resistant Infrared Thermometer with 8:1 Distance-to-Sight Ratio. Model with NIST-Traceable Calibration User Manual Stick-Style Water-Resistant Infrared Thermometer with 8:1 Distance-to-Sight Ratio with NIST-Traceable Calibration Model 20250-09 THE STANDARD IN PRECISION MEASUREMENT Introduction The Digi-Sense

More information

1.0 ACCREDITATION / REGISTRATION 2.0 PRODUCT DESCRIPTION 3.0 CERTIFIED VALUES AND UNCERTAINTIES. Assay Information:

1.0 ACCREDITATION / REGISTRATION 2.0 PRODUCT DESCRIPTION 3.0 CERTIFIED VALUES AND UNCERTAINTIES. Assay Information: 1.0 ACCREDITATION / REGISTRATION INORGANIC VENTURES is accredited to ISO Guide 34, "General Requirements for the Competence of Reference Material Producers" and ISO/IEC 17025, "General Requirements for

More information

Chapter 2 Atoms and the Periodic Table

Chapter 2 Atoms and the Periodic Table Chapter 2 1 Chapter 2 Atoms and the Periodic Table Solutions to In-Chapter Problems 2.1 Each element is identified by a one- or two-letter symbol. Use the periodic table to find the symbol for each element.

More information

Single Analyte Custom Grade Solution. CGWH2O1 M2-W H2O µg/ml ea: Tungsten Ammonium Metatungstate

Single Analyte Custom Grade Solution. CGWH2O1 M2-W H2O µg/ml ea: Tungsten Ammonium Metatungstate 1.0 ACCREDITATION / REGISTRATION INORGANIC VENTURES is accredited to ISO Guide 34, "General Requirements for the Competence of Reference Material Producers" and ISO/IEC 17025, "General Requirements for

More information

4. The mass of a proton is approximately equal to the mass of A an alpha particle C a positron. B a beta particle D a neutron

4. The mass of a proton is approximately equal to the mass of A an alpha particle C a positron. B a beta particle D a neutron 1. Which particles have approximately the same mass? A an electron and an alpha particle B an electron and a proton C a neutron and an alpha particle D a neutron and a proton 2. Which phrase describes

More information

Note that the protons and neutrons are each almost 2,000 times more massive than an electron; What is the approximate diameter of an atom?

Note that the protons and neutrons are each almost 2,000 times more massive than an electron; What is the approximate diameter of an atom? Atomic Structure and the Periodic Table Evolution of Atomic Theory The ancient Greek scientist Democritus is often credited with developing the idea of the atom Democritus proposed that matter was, on

More information

Jumbo Cross Beam Ionizer

Jumbo Cross Beam Ionizer Jumbo Cross Beam Ionizer Version 1.0 September 30, 2008 Page 1 of 19 Table of Contents Cross Beam Ionizer... 1 Table of Contents... 2 1.0 Packing List... 3 1.1 Packing List for Cross Beam Ionizer... 3

More information

The RX-6000 Sulfur in Oil Analyzer For the analysis of Sulfur in Oil and other elements from S to U

The RX-6000 Sulfur in Oil Analyzer For the analysis of Sulfur in Oil and other elements from S to U Oxford House, 20 Oxford St Newbury, Berkshire. RG14 1JB UK. sales@spectrolab.eu sales@spectrolab.co.uk Offices in UK, EU, Greece, Dubai The RX-6000 Sulfur in Oil Analyzer For the analysis of Sulfur in

More information

8. Relax and do well.

8. Relax and do well. CHEM 1314 3;30 pm Theory Exam III John III. Gelder November 13, 2002 Name TA's Name Lab Section INSTRUCTIONS: 1. This examination consists of a total of 8 different pages. The last page include a periodic

More information

Radiation Detection and Measurement

Radiation Detection and Measurement Radiation Detection and Measurement June 2008 Tom Lewellen Tkldog@u.washington.edu Types of radiation relevant to Nuclear Medicine Particle Symbol Mass (MeV/c 2 ) Charge Electron e-,! - 0.511-1 Positron

More information

Manufacturing and Measurement of photon-emitting Wide Area Reference Sources according to ISO 8769

Manufacturing and Measurement of photon-emitting Wide Area Reference Sources according to ISO 8769 Manufacturing and Measurement of photon-emitting Wide Area Reference Sources according to ISO 8769 Klaus Thieme Eckert & Ziegler Nuclitec GmbH Braunschweig 1 Content Introduction Measurements and Results

More information

Quality control of neutron-absorber materials for the nuclear fuel cycle, Principle of the JEN-3 neutron Backscattering gauge

Quality control of neutron-absorber materials for the nuclear fuel cycle, Principle of the JEN-3 neutron Backscattering gauge Quality control of neutron-absorber materials for the nuclear fuel cycle, Principle of the JEN-3 neutron Backscattering gauge Hamid MAKIL (CEADRT/LIST/LCAE) Patrick BRISSET (IAEA) ICARST 2017, 24 28 April

More information

ß + RADIATION. Choose your application of. chromatography controlled. chemical purity TLC PET GABI. PET GABI 2x2 Nal (Tl) 0 1V output.

ß + RADIATION. Choose your application of. chromatography controlled. chemical purity TLC PET GABI. PET GABI 2x2 Nal (Tl) 0 1V output. www.raytest.com Choose your application of ß + RADIATION chromatography stand alone software controlled chemical purity HPLC PET GABI 2x2 Nal (Tl) 0 1V output PET GABI 2x2 Nal (Tl) Gina-PCcontrolled TLC

More information

Budget Uncertainty and Minimum Detectable Concentrations for the INAA Laboratory of the ETRR-2

Budget Uncertainty and Minimum Detectable Concentrations for the INAA Laboratory of the ETRR-2 Budget Uncertainty and Minimum Detectable Concentrations for the INAA Laboratory of the ETRR2 M.Y. Khalil and Kh.. A. Elsakhawy CONTENTS Accreditation of INAA Lab What we wanted to do The ETRR2 What have

More information

Using the Periodic Table

Using the Periodic Table MATH SKILLS TRANSPARENCY WORKSHEET Using the Periodic Table 6 Use with Chapter 6, Section 6.2 1. Identify the number of valence electrons in each of the following elements. a. Ne e. O b. K f. Cl c. B g.

More information

Measurement of induced radioactivity in air and water for medical accelerators

Measurement of induced radioactivity in air and water for medical accelerators Measurement of induced radioactivity in air and water for medical accelerators K. Masumoto 1, K. Takahashi 1, H. Nakamura 1, A. Toyoda 1, K. Iijima 1, K. Kosako 2, K. Oishi 2, F. Nobuhara 1 High Energy

More information

GM Pancake Probe Victoreen Model D

GM Pancake Probe Victoreen Model D Radiation Safety RS GM Pancake Probe Victoreen Model 489-110D All purpose GM Pancake Probe detects alpha, beta, gamma, and x-ray radiations Used in nuclear medicine, diagnostic x-ray, and geological and

More information

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor DMP Industrial Pressure Transmitter for Low Pressure Stainless Steel Sensor accuracy according to IEC 60770: : 0.5 % FSO option: 0.5 / 0. % FSO Nominal pressure from 0... 00 mbar up to 0... 60 bar Output

More information

Chapter Seven (Nuclear Detectors)

Chapter Seven (Nuclear Detectors) Al-Mustansiriyah University College of Science Physics Department Fourth Grade Nuclear Physics Dr. Ali A. Ridha Chapter Seven (Nuclear Detectors) Ionizing radiation is rarely detected directly. Instead,

More information

Electron Configurations

Electron Configurations Section 3 Electron Configurations Key Terms electron configuration Pauli exclusion principle noble gas Aufbau principle Hund s rule noble-gas configuration Main Ideas Electrons fill in the lowest-energy

More information

RADEAGLET. Lightweight Handheld Radioisotope Identification Device

RADEAGLET. Lightweight Handheld Radioisotope Identification Device RADEAGLET Lightweight Handheld Radioisotope Identification Device Weighing Only 900 grams, the RADEAGLET is the Lightest HH-RIID in the world! The Perfect Instrument for First Responders Who Need to Wear

More information

Catalog # The Sta-Saf System. Reverse Buckling Technology A SME

Catalog # The Sta-Saf System. Reverse Buckling Technology A SME Catalog #77-4001 The Sta-Saf System Reverse Buckling Technology A SME Sta-Saf System The Sta-Saf System includes 11 reverse buckling rupture disk models. These rupture disks offer the optimum performance

More information

Capacitors and Inductors Resistor: a passive element which dissipates energy only Two important passive linear circuit elements: 1) Capacitor 2) Inductor Introduction Capacitor and inductor can store energy

More information

Vacuum capacitors overview Capacitor selection guides

Vacuum capacitors overview Capacitor selection guides JENNINGS TECHNOLOGY Vacuum capacitors overview Capacitor selection guides Capacitors by type Capacitor type Vacuum variable Capacity max. (pf) Test voltage / Hz Model no. series Page number 7.,, 1 CVDD-

More information

Teacher Workbooks. Science and Nature Series. Atomic Structure, Electron Configuration, Classifying Matter and Nuclear Chemistry, Vol.

Teacher Workbooks. Science and Nature Series. Atomic Structure, Electron Configuration, Classifying Matter and Nuclear Chemistry, Vol. Teacher Workbooks Science and Nature Series Atomic Structure, Electron Configuration, Classifying Matter and Nuclear Chemistry, Vol. 1 Copyright 23 Teachnology Publishing Company A Division of Teachnology,

More information

Chemical Engineering 412

Chemical Engineering 412 Chemical Engineering 412 Introductory Nuclear Engineering Lecture 26 Radiation Detection & Measurement II Spiritual Thought 2 I would not hold the position in the Church I hold today had I not followed

More information

PHYS 3650L - Modern Physics Laboratory

PHYS 3650L - Modern Physics Laboratory PHYS 3650L - Modern Physics Laboratory Laboratory Advanced Sheet Photon Attenuation 1. Objectives. The objectives of this laboratory exercise are: a. To measure the mass attenuation coefficient at a gamma

More information

Tap Changer Type MHF III Specification, Assembly and Materials

Tap Changer Type MHF III Specification, Assembly and Materials Tap Changer Type MHF III Specification, ssembly and Materials Descriptions General Specifications Remarks available in one, two or three phase applications shaft length available in variable sizes connection

More information

Nucleus. Electron Cloud

Nucleus. Electron Cloud Atomic Structure I. Picture of an Atom Nucleus Electron Cloud II. Subatomic particles Particle Symbol Charge Relative Mass (amu) protons p + +1 1.0073 neutrons n 0 1.0087 electrons e - -1 0.00054858 Compare

More information

Single Analyte Custom Grade Solution g/ml (measured at 20 ± 1 ºC) ICP Assay NIST SRM 3162a Lot Number:

Single Analyte Custom Grade Solution g/ml (measured at 20 ± 1 ºC) ICP Assay NIST SRM 3162a Lot Number: 1.0 ACCREDITATION / REGISTRATION INORGANIC VENTURES is accredited to ISO Guide 34, "General Requirements for the Competence of Reference Material Producers" and ISO/IEC 17025, "General Requirements for

More information

1.0 ACCREDITATION / REGISTRATION 2.0 PRODUCT DESCRIPTION 3.0 CERTIFIED VALUES AND UNCERTAINTIES. Assay Information:

1.0 ACCREDITATION / REGISTRATION 2.0 PRODUCT DESCRIPTION 3.0 CERTIFIED VALUES AND UNCERTAINTIES. Assay Information: 1.0 ACCREDITATION / REGISTRATION INORGANIC VENTURES is accredited to ISO Guide 34, "General Requirements for the Competence of Reference Material Producers" and ISO/IEC 17025, "General Requirements for

More information

Amphenol. Amphenol-Tuchel Electronics GmbH. Circular Connectors C 091 A/B/D Series

Amphenol. Amphenol-Tuchel Electronics GmbH. Circular Connectors C 091 A/B/D Series Amphenol Amphenol-Tuchel Electronics GmbH Circular Connectors C 09 A/B/D Series The Company Amphenol-Tuchel Electronics GmbH is a member of the USA based Amphenol Corporation. With our own global presence

More information

Isotope Production at High Energy Leonard Mausner

Isotope Production at High Energy Leonard Mausner Isotope Production at High Energy Leonard Mausner Brookhaven National Laboratory Upton, New York, USA Facility Description The Brookhaven Linac Isotope Producer (BLIP) was the world s first facility to

More information

RADIOACTIVE SAMPLE EFFECTS ON EDXRF SPECTRA

RADIOACTIVE SAMPLE EFFECTS ON EDXRF SPECTRA 90 RADIOACTIVE SAMPLE EFFECTS ON EDXRF SPECTRA Christopher G. Worley Los Alamos National Laboratory, MS G740, Los Alamos, NM 87545 ABSTRACT Energy dispersive X-ray fluorescence (EDXRF) is a rapid, straightforward

More information

FRAM V5.2. Plutonium and Uranium Isotopic Analysis Software

FRAM V5.2. Plutonium and Uranium Isotopic Analysis Software V5.2 Plutonium and Uranium Isotopic Analysis Software Advanced Isotopic Ratio Analysis Software for HPGe Gamma-Ray Spectra Analyzes Pu, and a wide variety of heterogeneous samples containing Pu, Am, U,

More information

ANALYSIS CERTIFICATE OF 1.0 ACCREDITATION / REGISTRATION 2.0 PRODUCT DESCRIPTION 3.0 CERTIFIED VALUES AND UNCERTAINTIES. Assay Information:

ANALYSIS CERTIFICATE OF 1.0 ACCREDITATION / REGISTRATION 2.0 PRODUCT DESCRIPTION 3.0 CERTIFIED VALUES AND UNCERTAINTIES. Assay Information: 300 Technology Drive Christiansburg, VA 24073. USA inorganicventures.com CERTIFICATE OF ANALYSIS tel: 800.669.6799. 540.585.3030 fax: 540.585.3012 info@inorganicventures.com 1.0 ACCREDITATION / REGISTRATION

More information

CERTIFICATE OF. Single Analyte Custom Grade Solution g/ml (measured at 20 ± 4 ºC) Graviametric NIST SRM Lot Number: See Sec. 4.

CERTIFICATE OF. Single Analyte Custom Grade Solution g/ml (measured at 20 ± 4 ºC) Graviametric NIST SRM Lot Number: See Sec. 4. CERTIFICATE OF ANALYSIS 300 Technology Drive Christiansburg, VA 24073. USA inorganicventures.com tel: 800.669.6799. 540.585.3030 fax: 540.585.3012 info@inorganicventures.com 1.0 ACCREDITATION / REGISTRATION

More information

Essential Chemistry for Biology

Essential Chemistry for Biology 1 Chapter 2 Essential Chemistry for Biology Biology and Society: More Precious than Gold A drought is a period of abnormally dry weather that changes the environment and one of the most devastating disasters.

More information

Connector~Tech Providing Harsh Environment Connector

Connector~Tech   Providing Harsh Environment Connector Connector~Tech www.connectortech.com.au Providing Harsh Environment Connector SOLUTIONS Tajimi TC18 series connectors are water-pro up to 30 meters in depth. Economical and highly reliable construction

More information

Auger Electron Spectroscopy (AES)

Auger Electron Spectroscopy (AES) 1. Introduction Auger Electron Spectroscopy (AES) Silvia Natividad, Gabriel Gonzalez and Arena Holguin Auger Electron Spectroscopy (Auger spectroscopy or AES) was developed in the late 1960's, deriving

More information

RADEAGLE. Next Generation Radioisotope Identification Device. Detection and Identification: Fast, Accurate and Easy

RADEAGLE. Next Generation Radioisotope Identification Device. Detection and Identification: Fast, Accurate and Easy RADEAGLE Next Generation Radioisotope Identification Device Detection and Identification: Fast, Accurate and Easy RADEAGLE RADEAGLE is a state-of-the-art handheld, radioisotope identification device (RIID)

More information