VA10S Series VA10S VA10S- Nitto Instruments Co.,ltd. Glass Rotameters. Specifications. Materials

Size: px
Start display at page:

Download "VA10S Series VA10S VA10S- Nitto Instruments Co.,ltd. Glass Rotameters. Specifications. Materials"

Transcription

1 V0S Series Nitto Instruments o.,ltd V0S Glass rotameter are the new products of our company, compared with the other domestic products of the same type, it has advantages of high measuring precision,good interchangeability, multiple connection ways,especially the value of flow rate of the flow meter is in millimeter scale mark, which is capable of providing actual flow scale according to the temperature,, density, and viscosity of different flows, solving the problem of indication correction. s for the ways of connection, use pipe thread connection,. Specifications 5 V0S-5 5 V0S-5 Water (/h) ~ 0~00 5~ ~0 00~000 60~600 ~0 ir (m/h) 0.~. 0.~.~ ~0 ~0 ~0 5~.0.0 Temp. ccuracy -0 ~ 0 ±.5% V0S- 60~600 ~0 0~00 5~ ~0 0.9 V0S- 0~00 60~ ~0000 ~6m³/h ~0 0~00 0~ x0 6x0 x0 x0 8 8 Thread 5 /'' NT BS/'' 75 '' NT BS''.8 9 ½'' NT BS½''.7 6 '' NT BS'' 5.9 0SS,6 or TE Steel pipe l or 0SS 5 5# 0SS or 5# 5 V0S : TE : ir loat material { { S: 0SS : fluid : 0SS * onnection { : b V0S- S V0S- 5 0 /h

2 S0S Series S0S Glass rotameter are the new products of our company, compared with the other domestic products of the same type, it has advantages of high measuring precision,good interchangeability, multiple connection ways,especially the value of flow rate of the flow meter is in millimeter scale mark, which is capable of providing actual flow scale according to the temperature,, density, and viscosity of different flows, solving the problem of indication correction. s for the ways of connection, use flexible pipe connection,. Specifications 5 S0S-5 5 S0S-5 Water (/h) ~ 0~00 5~ ~0 00~000 60~600 ~0 ir (m/h) 0.~. 0.~.~ ~0 ~0 ~0 5~.0.0 Temp. -0 ~ 0 ccuracy ±.5% S0S- 60~600 ~0 0~00 5~ ~0 0.9 S0S- 0~00 60~ ~0000 ~6m³/h ~0 0~00 0~ sizes 6x0 6x0 x0 x Thread /'' NT BS/'' 65 '' NT BS''.8 80 ½'' NT BS½''.7 0 '' NT BS'' 5.9 0SS,6 or TE Steel pipe 0SS or luminium S0S : TE : ir loat material { { S: 0SS : fluid : 0SS * onnection { : luminium S0S- S D S0S- 5 0 /h

3 0S Series Nitto Instruments o.,ltd 0S Glass rotameter are the new products of our company, compared with the other domestic products of the same type, it has advantages of high measuring precision,good interchangeability, multiple connection ways,especially the value of flow rate of the flow meter is in millimeter scale mark, which is capable of providing actual flow scale according to the temperature,, density, and viscosity of different flows, solving the problem of indication correction. s for the ways of connection, use flange connection,. Temperature limit: 0 ccuracy: ±.5% Specifications 5 0S-5 5 0S-5 Water (/h) ~ 0~00 5~ ~0 00~000 60~600 ~0 ir (m/h) 0.~. 0.~.~ ~0 ~0 ~0 5~.0.0 Temp. -0 ~ 0 0S- 60~600 ~0 0~00 5~ ~ S- 0~00 60~ ~0000 ~6m³/h ~0 0~00 0~ Din lange 5 5 6x0 6x0 x0 x SS,6 or TE Steel pipe 5# Steel or 0SS* luminium or 0SS 0S : ir { : fluid : TE loat material { S: 0SS : 0SS * onnection { : luminium 0S- S D E 0S- 5 0 /h

4 V0S Series V0S Glass rotameter are the new products of our company, compared with the other domestic products of the same type, it has advantages of high measuring precision,good interchangeability, multiple connection ways,especially the value of flow rate of the flow meter is in millimeter scale mark, which is capable of providing actual flow scale according to the temperature,, density, and viscosity of different flows, solving the problem of indication correction. s for the ways of connection, use flange connection,. Specifications Temperature limit: 0 ccuracy: ±.5% 5 5 V0S-5 V0S-5 V0S-5 V0S-5 V0S- V0S- Water(/h) ~ 0~00 5~ ~0 00~000 60~600 ~0 60~600 ~0 0~00 ir(m/h) 0.~. 0.~.~ ~0 ~0 ~0 5~ 5~ ~ Temp. -0 ~ 0 V0S- V0S- 0~00 60~ ~0000 ~6m³/h ~0 0~00 0~ Thread BS/NT 5 x5 58 /'',/8', /''. 5 x 65x '',/'','' ½'',½''.8. 85x0 '', '' 5. 0SS, 6, TE V0S : ir { : fluid loat material { : TE S: 0SS : 0SS onnection{ : V : TE * b a V0S- S V0S- 5 0 /h

5 S0S Series Nitto Instruments o.,ltd S0S Glass rotameter are the new products of our company, compared with the other domestic products of the same type, it has advantages of high measuring precision,good interchangeability, multiple connection ways,especially the value of flow rate of the flow meter is in millimeter scale mark, which is capable of providing actual flow scale according to the temperature,, density, and viscosity of different flows, solving the problem of indication correction. s for the ways of connection, use flange connection,. Temperature limit: 0 Specifications ccuracy: ±.5% Water(/h) ir(m/h) Temp. 5 S0S-5 5 S0S-5 S0S- ~ 0~00 5~ ~0 00~000 60~600 ~0 60~600 ~0 0~00 0.~. 0.~.~ ~0 ~0 ~0 5~ 5~ ~ ~ 0 S0S- 0~00 60~ ~0000 ~6m³/h ~0 0~00 0~ B 5 x x x5 85x SS, 6, TE luminium luminium 0SS, luminium S0S S0S- : ir { : fluid loat material : 0SS* onnection{ : luminium { S : TE* S: 0SS B S0S- 5 0 /h

6 0S Series 0S Glass rotameter are the new products of our company, compared with the other domestic products of the same type, it has advantages of high measuring precision,good interchangeability, multiple connection ways,especially the value of flow rate of the flow meter is in millimeter scale mark, which is capable of providing actual flow scale according to the temperature,, density, and viscosity of different flows, solving the problem of indication correction. s for the ways of connection, use flange connection,. Temperature limit: 0 Specifications ccuracy: ±.5% Water(/h) ir(m/h) Temp. 5 0S-5 5 0S-5 0S- ~ 0~00 5~ ~0 00~000 60~600 ~0 60~600 ~0 0~00 0.~. 0.~.~ ~0 ~0 ~0 5~ 5~ ~ ~ 0 0S- 0~00 60~ ~0000 ~6m³/h ~0 0~00 0~ D E 5 x5 ø95 ø65 -ø5 5 x 65x5 5 ø5 ø5 ø85 ø0 -ø5 -ø x0 ø60 ø5 -ø SS, 6, TE 0SS, 5# 0S : ir { : fluid loat material : 0SS* onnection{ : luminium { : TE* S: 0SS 0S- S D E 0S- 5 0 /h

7 GS Series Nitto Instruments o.,ltd G s series glass rotameter with safety cover of special laminated glass,with high safety factor,and easy to replace glass tube and float. Specifications Temperature limit: 0 Temp. ccuracy: ±.5% Water(/h) ir(m/h) 5 5 GS-5 GS-5 GS-5 GS-5 ~ 0~00 5~ ~0 * 00~000 60~600 ~0* 0.~. 0.~.~ ~0* ~0 ~0 5~ *.0.0 GS- GS- 60~600 ~0 0~00* 5~ ~0* ~0 GS- GS- 0~00 60~ ~0000 ~6m³/h* ~0 0~00 0~00* GS-65 5~5m³/h* 8~m³/h* 80~800* ~00* GS-80 8~m³/h* 0~m³/h* Note:ex-corrosive type can't make * flow range. ~00* 00~0* 0. (flange type) D E D E x0 5x9 6x78 9x66 x60 x60 0 ø65 ø85 ø0 ø5 ø5 ø60 ø95 ø5 ø5 ø60 ø80 ø00 - ø - ø8 8- ø a GS b lange connection { : ir Medium{ : fluid loat : TE maerial { S: 0SS 0SS, 6SS, TE 5# steel board nti-explosion glass 5 HT0-, 0SS, 6SS 0SS, 6SS GS- S GS- /h

8 GV Series GV series glass rotameter with safety cover of special laminated glass,with high safety factor,and easy to replace glass tube and float. Temperature limit: 0 ccuracy: ±.5% Specifications Water(/h) ir(m/h) Temp. 5 GV-5 GV-5 ~ 0~00 5~ ~0 * 0.~. 0.~.~ ~0*.0 5 GV-5 GV-5 00~000 60~600 ~0* ~0 ~0 5~ *.0 GV- GV- 60~600 ~0 0~00* 5~ ~0* ~0 GV- GV- 0~00 60~ ~0000 ~6m³/h* ~0 0~00 0~00* 0.6 Note:ex-corrosive type can't make * flow range. (thread type) 5 a 5 5 7x0 5x9 6x78 9x66 G (NT/BS) /'' '' ½'' '' b GV Thread connection { 0SS, 6SS*, TE* 5# steel board nti-explosion glass 5 G HT0-, 0SS, 6SS* 0SS, 6SS* : ir Medium{ : fluid S loat : TE* maerial { S: 0SS S GV- GV- /h

9 V0S Series Nitto Instruments o.,ltd V0S glass rotameter are the new products of our company.compared with the other domestic products of the same type,it has advantages of high measuring precision,good interchangeability,multiple connection ways,especially the value of flow rate of the flow meter is in millimeter scale mark,which is capable of providing actual flow scale according to the temperature,,density,and viscosity of different flows,solving the problem of indication correction.s for the ways of connection.the loose flange structure is available,with both conventional type and corrosion-proof type. Temperature limit: 0 ccuracy: ±.5% V0S 6SS* :TE*.0 S: 0SS ~6m³/h DN G (NT/BS) /'' '' ½'' '' 0SS, 6SS*, TE* 0SS 0SS, 6SS*

10 V0G Series V0G glass rotameter are the new products of our company.compared with the other domestic products of the same type,it has advantages of high measuring precision,good interchangeability,multiple connection ways,especially the value of flow rate of the flow meter is in millimeter scale mark,which is capable of providing actual flow scale according to the temperature,,density,and viscosity of different flows,solving the problem of indication correction.s for the ways of connection.the loose flange structure is available,with both conventional type and corrosion-proof type. Temperature limit: 0 ccuracy: ±.5% V0G 6SS* V0G-5.0 :TE* S: 0SS lamp.with. Without V0G-5.0 V0G- V0G- 0.9 V0G- ~6m³/h 0.7 V0G- D B D G B SS, 6SS*, TE* 0SS 0SS, 6SS* Spare part of clamp

11 Series Nitto Instruments o.,ltd series of glass rotor flowmeter is an integrated product by cone-shaped glass tube,float,flanges.the installation is easy and the flowmeter is adjustable,the flowmeter is used in ranges such as semi-conductor chemicals etc. temperature limit: V 60 0SS 00 ccuracy: ±% Specifications DN mm Water (/h) (N/min) 0SS V m³/h.-m³/h.5-5m³/h.-m³/h.5-5m³/h.8-8m³/h.8-8m³/h -0m³/h -m³/h -m³/h 5-m³/h 6-60m³/h 6-60m³/h 7-70m³/h 0-00m³/h Nm³/h 0-00Nm³/h 5-Nm³/h 0-00Nm³/h 5-Nm³/h 0-00Nm³/h 5-Nm³/h 5-Nm³/h -0Nm³/h -0Nm³/h -0Nm³/h Nm³/h Nm³/h Nm³/h Nm³/h (flange type) Unit: mm

12 V Series V series of glass rotor flowmeter is an integrated product by cone-shaped glass tube,float,flanges.the installation is easy and the flowmeter is adjustable,the flowmeter is used in ranges such as semi-conductor chemicals etc. temperature limit: V 60 0SS 00 ccuracy: ±% Specifications DN mm (/h) Measuring ragne (N/min) 0SS V m³/h.-m³/h.5-5m³/h Nm³/h 0-00Nm³/h 5-Nm³/h m³/h 0-00Nm³/h.5-5m³/h.8-8m³/h 5-Nm³/h 0-00Nm³/h.8-8m³/h 5-Nm³/h -0m³/h -m³/h -m³/h 5-Nm³/h -0Nm³/h -0Nm³/h m³/h 6-60m³/h -0Nm³/h Nm³/h 6-60m³/h Nm³/h 7-70m³/h 0-00m³/h Nm³/h Nm³/h V V (thread type: BS/NT) Unit: mm / / ¼ ½

13 DK800S Series Nitto Instruments o.,ltd DK800S is used for measuring tiny flow.with nice shape,and light-weighted,easy to install and repair.the taper pipe and float can be changed without spearating the whole machine into pieces.the flow scale is clear and acute,which is widely used in the chemical,petroleum,medical,food environmental protection and scientific research departments,for measuring one phase non-pulsating fluid(liquid or gas). temperature limit: 0 ccuracy: ±.5% limit:.0mpa DN Measuring ragne Water /h ir /h loat material agate /NT female /NT female /BS female /BS female.5 DK800S

Full Metal Variable Area Flow Meter and Counter

Full Metal Variable Area Flow Meter and Counter Full Metal Variable rea Flow Meter and Counter for horizontal and vertical mounting measuring monitoring analysing Special versions up to 600 bar Measuring range: 10-100...00-000 L/h water 0.3-3.0...-0

More information

Flow Measurement: Physical principle employed in various types of flow meters. PART 4 PREPARED BY: ESO OLUWATOBILOBA

Flow Measurement: Physical principle employed in various types of flow meters. PART 4 PREPARED BY: ESO OLUWATOBILOBA Flow Measurement: Physical principle employed in various types of flow meters. PART 4 PREPARED BY: ESO OLUWATOBILOBA Pressure Differential Flow Meters In a differential pressure drop device the flow is

More information

MX Series COMPACT AND USER FRIENDLY. Metal Tube Type Variable Area Flowmeter OUTLINE STANDARD SPECIFICATION MODEL CODE MX-400, MX-71 MX-52E

MX Series COMPACT AND USER FRIENDLY. Metal Tube Type Variable Area Flowmeter OUTLINE STANDARD SPECIFICATION MODEL CODE MX-400, MX-71 MX-52E OMPT ND USER FRIENDLY MX Series Metal Tube Type Variable rea Flowmeter OUTLINE MX Series flowmeter is the metal tube type variable area flowmeter having the unified face-to-face dimension. The compact

More information

Applicable Fluid. Accuracy. Flow Rate Range. Fluid Temperature. Fluid Viscosity. Connection Size. Flange Rating. Housing. Material. Blade.

Applicable Fluid. Accuracy. Flow Rate Range. Fluid Temperature. Fluid Viscosity. Connection Size. Flange Rating. Housing. Material. Blade. TOKICO TURINE METER GS-F211E- Overview Turbine meter has an excellent performance with its distinctive structure. Comparing with the flow meter using other method, it has compact and lighter design and

More information

About the Calibration of Rotameter

About the Calibration of Rotameter About the Calibration of Rotameter IVANOV Valentin Ganchev Technical University of Sofia, Bulgaria, vgi@tu-sofia.bg Abstract This work on basis of literary studies and analysis of the author are examined

More information

K Series SIGHT GLASS FOR CONVENIENT OBSERVATION OF LIQUID FLOW GENERAL

K Series SIGHT GLASS FOR CONVENIENT OBSERVATION OF LIQUID FLOW GENERAL FOR CONVENIENT OBSERVATION OF IQUID FOW K Series SIGHT GASS GENERA K series are sight glasses for observation of various liquids. Different types are available to meet applications and requirements. Cast

More information

Cone differential pressure flow meter. Operating manual WIDE PLUS PRECISION INSTRUMENTS CO., LTD.

Cone differential pressure flow meter. Operating manual WIDE PLUS PRECISION INSTRUMENTS CO., LTD. Cone differential pressure flow meter Operating manual WIDE PLUS PRECISION INSTRUMENTS CO., LTD. INDEX Introduction 2 Principle Application The characteristics of flow meter Specification Technical features

More information

DELTA FLOWMETER FOR GAS SERVICE (INSERTION TYPE) MODEL VF SERIES

DELTA FLOWMETER FOR GAS SERVICE (INSERTION TYPE) MODEL VF SERIES DETA FOWMETER FOR GAS SERVICE (INSERTION TYPE) MODE VF SERIES GENERA SPECIFICATION GS. No. GBD0-0-E GENERA In the thermistor type Delta meter, a probe inserted in the pipeline detects the representative

More information

An Essential Requirement in CV Based Industrial Appliances.

An Essential Requirement in CV Based Industrial Appliances. Measurement of Flow P M V Subbarao Professor Mechanical Engineering Department An Essential Requirement in CV Based Industrial Appliances. Mathematics of Flow Rate The Scalar Product of two vectors, namely

More information

V-Cone Flowmeter DATASHEET

V-Cone Flowmeter DATASHEET V-Cone Flowmeter ATASHEET JUNHO 013 IntraCone Cone Flow Meter Type: ICM etail: Cone-Element Technical Information 05/011 FLOW THE SPECIALIST IN LEVEL AN FLOW Cone Flow Meter Technical Information Intra-Automation

More information

SELECCIÓN DE CAUDALIMETROS. Tablas de Fabricantes

SELECCIÓN DE CAUDALIMETROS. Tablas de Fabricantes SELECCIÓN DE CAUDALIMETROS Tablas de Fabricantes Flow Meter Selection Table http://www.instrumart.com/content.aspxcontentid=219 Página 1 de 1 17/09/2007 KEY Best for this application OK with some exceptions

More information

Its modular concept allows to build up a ball valve for any degree of automation and any kind of application

Its modular concept allows to build up a ball valve for any degree of automation and any kind of application Type 2657...59 DN 10 up to 80 mm; Plastic; 2/2 way dvantages/benefits ntegrated pilot valves, position feed-back and limit switches available Customized system solutions with Burkert valves & sensors With

More information

AM-1000 Series COMPACT FLOWMETER

AM-1000 Series COMPACT FLOWMETER METAL TUBE VARIABLE AREA FLOWMETER AM0 Series COMPACT FLOWMETER GENERAL AM0 series are most well accepted metal tube flowmeters which have been developed based on the long time experience of TOKYO KEISO

More information

PR CYCLONE SECONDARY SHUTOFF

PR CYCLONE SECONDARY SHUTOFF EN PR CYCLONE SECONDARY SHUTOFF ORIGINAL INSTRUCTIONS CYCLONE SECONDARY SHUTOFF PR530 CYCLONE SECONDARY SHUTOFF PR330 CYCLONE SECONDARY SHUTOFF PR200-250 CYCLONE SECONDARY SHUTOFF PR150 TECHNICAL DATA

More information

v = 00,20 m/s Thermal Flow Sensors TA with thin-film sensor element Probes Probe guides Measuring tubes

v = 00,20 m/s Thermal Flow Sensors TA with thin-film sensor element Probes Probe guides Measuring tubes with thin-film sensor element Probes Probe guides Measuring tubes Examples of Application Flow measurements also in hazardous locations Ex zone 0 or zone 1 in clean rooms in air conditioning and ventilating

More information

Gear Wheel Flowmeter for viscous liquids Model DZR. (option 3):

Gear Wheel Flowmeter for viscous liquids Model DZR. (option 3): Gear Wheel Flowmeter for viscous liquids measuring monitoring analysing DZR easuring range:. -... 3-7 l/min Accuracy: ±.3... ±1% of reading p max : bar t max : 1 C Orocess O connection: G ⅛, G ⅜, G ½,

More information

Electromagnetic Flowmeter

Electromagnetic Flowmeter Overview Flokal B.V. smart electromagnetic flow meter is hallmarked by its high performance and reliability that are based on successful, field-proven technology. It s being widely used in industries such

More information

Metal oil filler and air breather filler caps. Bayonet connection. Reservoir holes. TA46 B (Materials)

Metal oil filler and air breather filler caps. Bayonet connection. Reservoir holes. TA46 B (Materials) Metal oil filler and air Series T 46 4 5 6 4 ayonet connection Ø 46 7 8 46 Reservoir holes T46 (Materials) M5 - Cover: Chrome Plated Steel - Filter element: Impregnated paper Polyurethane 64-6 - Flange:

More information

COMPACT FLOWMETER TO COVER ALL POSSIBLE APPLICATIONS. METAL TUBE AM-1000 Series GENERAL FEATURES TG-F962-0E APR.,2000 AM-1000 COMPACT FLOWMETER

COMPACT FLOWMETER TO COVER ALL POSSIBLE APPLICATIONS. METAL TUBE AM-1000 Series GENERAL FEATURES TG-F962-0E APR.,2000 AM-1000 COMPACT FLOWMETER AM0 TO COVER ALL POSSIBLE APPLICATIONS METAL TUBE AM0 Series GENERAL AM0 series are most well accepted metal tube flowmeters which have been developed based on the long time experience of TOKYO KEISO in

More information

Volumetric Flow Measurement

Volumetric Flow Measurement Volumetric Flow Measurement TVF Series Vortex Flow Meter Xi an Tosilon Automation Co., Ltd No.299, Daqing Rd, Lianhu District, Xi'an Shaanxi, China Tel: +86-29-8823 8550 info@tosilon.com; www.tosilon.com

More information

all stainless steel transducer multimedia compatibility

all stainless steel transducer multimedia compatibility all stainless steel transducer multimedia compatibility High-Performance Silicon technology LARGE INVENTORY Fast Shipment! 0-0.07 to 0-690 bar 100 mv, 0 to 5 V, and 4 to 20 ma Outputs U 1, 2 & 5 psi Low

More information

AM-1000 Series COMPACT FLOWMETER

AM-1000 Series COMPACT FLOWMETER METAL TUBE VARIABLE AREA FLOWMETER AM0 Series COMPACT FLOWMETER GENERAL AM0 series are most well accepted metal tube flowmeters which have been developed based on the long time experience of TOKYO KEISO

More information

Flow Measurement in Pipes and Ducts COURSE CONTENT

Flow Measurement in Pipes and Ducts COURSE CONTENT Flow Measurement in Pipes and Ducts Dr. Harlan H. Bengtson, P.E. COURSE CONTENT 1. Introduction This course is about measurement of the flow rate of a fluid flowing under pressure in a closed conduit.

More information

Coriolis Mass Flowmeter. (MCM Series) 100% Customer Satisfaction MAXIFLO TM. Coriolis Mass Flowmeter Series MCM

Coriolis Mass Flowmeter. (MCM Series) 100% Customer Satisfaction MAXIFLO TM. Coriolis Mass Flowmeter Series MCM MAXIFO TM Features MaxiFlo Coriolis Mass Flowmeter series MCM is a mass flow meter that measures mass flow, density and temperature of liquids, slurries and gases. And it even measures oil content in water.

More information

Applied Fluid Mechanics

Applied Fluid Mechanics Applied Fluid Mechanics 1. The Nature of Fluid and the Study of Fluid Mechanics 2. Viscosity of Fluid 3. Pressure Measurement 4. Forces Due to Static Fluid 5. Buoyancy and Stability 6. Flow of Fluid and

More information

v = m / s Thermal Flow Sensors TA with thin-film sensor element Probes Probe Guides Measuring Tubes

v = m / s Thermal Flow Sensors TA with thin-film sensor element Probes Probe Guides Measuring Tubes Thermal Flow Sensors TA with thin-film sensor element Probes Probe Guides Measuring Tubes Examples of Application Flow measurements also in hazardous locations X zone 0 or zone 1 in clean rooms in air

More information

Applied Fluid Mechanics

Applied Fluid Mechanics Applied Fluid Mechanics 1. The Nature of Fluid and the Study of Fluid Mechanics 2. Viscosity of Fluid 3. Pressure Measurement 4. Forces Due to Static Fluid 5. Buoyancy and Stability 6. Flow of Fluid and

More information

Flow Measurement in Pipes and Ducts COURSE CONTENT

Flow Measurement in Pipes and Ducts COURSE CONTENT Flow Measurement in Pipes and Ducts Dr. Harlan H. Bengtson, P.E. COURSE CONTENT 1. Introduction This course is about measurement of the flow rate of a fluid flowing under pressure in a closed conduit.

More information

( Single Case Construction )

( Single Case Construction ) OVL FLOWMETER Meter Size:,,,, ( Single ase onstruction ) Pocketless Design GENERL SPEIFITION GS.No.GBB--E GENERL The OVL flowmeter is a positive displacement type flowmeter comprising a pair of oval gear

More information

Fundamentals of Flow Metering

Fundamentals of Flow Metering Technical Data Sheet 00816-0100-3031 Fundamentals of Flow Metering A reliable flow indication is dependent upon the correct measurement of A and V. If, for example, air bubbles are present in the fluid,

More information

Processes and Process Variables

Processes and Process Variables Processes and Process Variables Processes and Process Variables Processes and Process Variables Processes and Process Variables average molecular weight = M y i M i Component Mol Fraction, y i M i N 2

More information

Instrumentation & Data Acquisition Systems

Instrumentation & Data Acquisition Systems Instrumentation & Data Acquisition Systems Section 5 -Flow Robert W. Harrison, PE Bob@TheHarrisonHouse.com Made in USA 1 The Perfect Flowmeter Infinite rangeability / turndown with negligible uncertainty

More information

Vortex Flow Meters. RVL Series Vortex Flow Meter

Vortex Flow Meters. RVL Series Vortex Flow Meter TM Vortex Meters RVL Series Vortex Meter pplications: Water/Wastewater I Water: Semiconductor, Institutional I Water Skids Semiconductor Equipment Slurry hemical Processing RINE FEERTE IN. ISO 900 : 000

More information

Flow rates to 590 l/min

Flow rates to 590 l/min LM 400-40 - 4 Maximum pressure bar Flow rates to 590 l/min Technical data housing (Materials) ead: nodized luminium ousing: nodized luminium Manifolds: Steel - Painted black ypass valve: Steel -way ball

More information

EX-EMERGENCY LIGHT FITTINGS

EX-EMERGENCY LIGHT FITTINGS EX-EMERGENCY LIGHT FITTINGS nllk 0...N 1-36 W Plastic version for Zone 2 and Zone 21/22 The explosion-protected light fittings of the series nllk 0 N are conform to the requirements of the ATEX-Directive

More information

DS 200P. Electronic Pressure Switch. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

DS 200P. Electronic Pressure Switch. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm accuracy according to IEC 600: standard: 0. % FSO option: 0. % FSO Nominal pressure from 0... 00 mbar up to 0... 0 bar

More information

High-efficiency Circulator Pump. Rio-Eco N / Rio-Eco Z N. Type Series Booklet

High-efficiency Circulator Pump. Rio-Eco N / Rio-Eco Z N. Type Series Booklet High-efficiency Circulator Pump Rio-Eco N / Rio-Eco Z N Type Series Booklet Legal information/copyright Type Series Booklet Rio-Eco N / Rio-Eco Z N KSB Aktiengesellschaft All rights reserved. The contents

More information

By-Pass. This voltage is proportional to the liquid level (threewire potentiometer circuit). The resistance reading can

By-Pass. This voltage is proportional to the liquid level (threewire potentiometer circuit). The resistance reading can " " ' " ' / The magnetic field which is in the ball or cylindrical floats actuates very small reed contacts through the wall of a guide tube and these pick up an uninterrupted measuring-circuit voltage

More information

14:1400 (0206) KRAL Volumeter - OMG

14:1400 (0206) KRAL Volumeter - OMG 14:1400 (0206) KRAL Volumeter - OMG OMG - Universal OMG The flowmeter for a wide range of applications Operating Conditions and Materials Flow Range: 0.1 to 7,500 l/min Max. Pressure: 250 bar Temperature

More information

Type M4 - SON - SO - MS

Type M4 - SON - SO - MS 9. REV. Type M - SON - SO - MS Aircaps Tank venting and water excluding aircaps. For installation on service tank air pipes. Inerted void spaces and ballast tanks In order to maintain inert gas pressure

More information

Gear Wheel Flow Meter for Viscous Fluids

Gear Wheel Flow Meter for Viscous Fluids Gear Wheel Flow Meter for Viscous Fluis measuring monitoring analysing Measuring range:. to 5 L/min Measuring accuracy: ±.3 up to ±1% of actual flow pmax: bar tmax: C rocess connection: G 1, G 3, G 1,

More information

LMP 210. Style B. Style S. Maximum pressure 60 bar F l o w r a t e s t o l / m i n

LMP 210. Style B. Style S. Maximum pressure 60 bar F l o w r a t e s t o l / m i n LMP 0 Style S Style Maximum pressure 60 bar F l o w r a t e s t o 7 0 l / m i n 6 Technical data Filter housing (Materials) Head: luminium Housing: nodised luminium ypass valve: Nylon - Steel Pressure

More information

Size : Ends : Min Temperature : Max Temperature : Materials : Brass

Size : Ends : Min Temperature : Max Temperature : Materials : Brass Size : Ends : Min Temperature : Max Temperature : DN 1/2" to 1 Free nut BSP, male or female - 10 C + 120 C Max Pressure : 25 Bars Specifications : Before or after water meter PTFE packing With free nut

More information

SECTION 1 - WHAT IS A BTU METER? BTU's = Flow x ΔT Any ISTEC BTU Meter System consists of the following main components:

SECTION 1 - WHAT IS A BTU METER? BTU's = Flow x ΔT Any ISTEC BTU Meter System consists of the following main components: SECTION 1 - WHAT IS A BTU METER? ISTEC BTU Meters measure energy usage by multiplying flow rate and temperature difference. As the water (or other liquid) passes through these lines, the multi-wing turbine

More information

SITRANS F flowmeters. SITRANS F US System information SITRANS F US Ultrasonic flowmeters 4/181

SITRANS F flowmeters. SITRANS F US System information SITRANS F US Ultrasonic flowmeters 4/181 Siemens AG 09 SITRANS F flowmeters System information Overview Siemens offers two types of ultrasonic flowmeters, in-line flowmeters and clamp-on flowmeters. This offers the end user the maximum flexibility

More information

Flow Monitoring Technologies in Oil and Gas. Don Ford, Technical Specialist Spartan Controls Ltd.

Flow Monitoring Technologies in Oil and Gas. Don Ford, Technical Specialist Spartan Controls Ltd. Flow Monitoring Technologies in Oil and Gas Don Ford, Technical Specialist Spartan Controls Ltd. Agenda Flow technologies at a glance Oil and Gas at a glance Select Flow Technologies in Depth Differential

More information

Integral V-Cone Flowmeter VD series

Integral V-Cone Flowmeter VD series TRANSMITTER DIRECTLY MOUNTED! SIMPLE AND EASY INSTALLATION Integral V-Cone Flowmeter VD series OUTLINE VD series Integral V-Cone Flowmeter is a differential pressure type flowmeter. Unlikely to existing

More information

THE ANSWER TO PROBLEMS OF: CORROSION, ABRASION, GRANULATED MATERIALS, POWDERS, SLUDGE, GAS ETC.

THE ANSWER TO PROBLEMS OF: CORROSION, ABRASION, GRANULATED MATERIALS, POWDERS, SLUDGE, GAS ETC. P PINC VLVE Mod. S pag. Mod. S pag. Mod. S pag. Mod. SD pag. Mod. S pag. Mod. S pag. 0 Mod. S pag. Mod. S pag. Mod. S pag. Mod. S0 pag. Mod. S pag. 0 Mod. S pag. Mod. S pag. Mod. S pag. Mod. S pag. TE

More information

SUMMER-17 EXAMINATION Model Answer. Subject Title: Fluid Flow Operations subject code: page 1 of 27

SUMMER-17 EXAMINATION Model Answer. Subject Title: Fluid Flow Operations subject code: page 1 of 27 Subject Title: Fluid Flow Operations subject code: page 1 of 7 Important Instructions to examiners: 1) The answers should be examined by key words and not as word-to-word as given in the model answer scheme.

More information

Amir Hossein Parvardi 1

Amir Hossein Parvardi 1 Instrumentation 1 1 School of Electrical & Computer Engineering University of Tehran (ECE) October 5, 2015 1 / 1 Flowmeters (ECE) October 5, 2015 2 / 1 Flowmeters Types of Flowmeters Types of Flowmeters

More information

VA Master FAM540 Metal Cone Variable Area Flowmeter

VA Master FAM540 Metal Cone Variable Area Flowmeter Contents Data Sheet Rev. B VA Master FAM50 Metal Cone Variable Area Flowmeter For metering liquids, gases and steam Graphic, 2-line display Magnet stick operation Configuration also possible with closed

More information

Size : Ends : Min Temperature : Max Temperature : Materials : Brass

Size : Ends : Min Temperature : Max Temperature : Materials : Brass Size : Ends : Min Temperature : Max Temperature : DN 1/2" to 1 Free nut BSP, male or female - 10 C + 120 C Max Pressure : 20 Bars Specifications : Before or after water meter PTFE packing With free nut

More information

Flowmeter Discharge Coefficient Estimation

Flowmeter Discharge Coefficient Estimation Bankston 1 Flowmeter Discharge Coefficient Estimation Elizabeth Bankston Team 1 Abstract An Edibon FME18 Flow Meter demonstration system was used to obtain experimental values for this experiment. The

More information

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm DMP P Industrial Pressure Transmitter Process Connections With Flush Welded Stainless Steel accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 % FSO Nominal pressure from 0... 00 mbar up

More information

Serie B2.1. Flanged ductile iron ball valve. made in. Application fields. Shut-off valves E U R O P E. 18

Serie B2.1. Flanged ductile iron ball valve. made in. Application fields. Shut-off valves E U R O P E. 18 erie B. Flanged ductile iron ball valve BRanDOni made in E U R O P E Application fields WATER CONdITIONING GA EATING INdUTRY FIRE FIGTING www.brandoni.it erie B. eries B. valves are shut-off ball valves

More information

DOG-1/-3. Oscillation Flowmeter. for gases. Measuring ranges: m 3 /h air : 120 C. p max. : PN 40; t max

DOG-1/-3. Oscillation Flowmeter. for gases. Measuring ranges: m 3 /h air : 120 C. p max. : PN 40; t max Oscillation Flowmeter for gases measuring monitoring analysing DOG1/3 Measuring ranges: 0.2 20... 200 20000 m 3 /h air p max : PN 40; t max : 120 C Connection: flange DN 25... DN 400 Material: cast iron,

More information

DN 1/4" to 4" Male, Female BSP - 10 C C Max Pressure : 30 Bars (up to DN1") Specifications : Anti blow-out stem PTFE packing Full bore

DN 1/4 to 4 Male, Female BSP - 10 C C Max Pressure : 30 Bars (up to DN1) Specifications : Anti blow-out stem PTFE packing Full bore Size : Ends : Min Temperature : Max Temperature : DN 1/4" to 4" Male, Female BSP - 10 C + 120 C Max Pressure : 30 Bars (up to DN1") Specifications : Anti blow-out stem PTFE packing Full bore Materials

More information

Inch Size Uni One-touch Fittings. Applicable Tubing. Tubing material. Specifications. Fluid Note 3)

Inch Size Uni One-touch Fittings. Applicable Tubing. Tubing material. Specifications. Fluid Note 3) Courtesy of C/Flodyne/ydradyne otion Control ydraulic Pneumatic Electrical echanical (00) 2-50 www.cmafh.com Guide Chuck Suitable for use with nylon and urethane. arge retaining force. The chuck provides

More information

TF-1000 Series MINI THERMAL MASS FLOWMETER PERFECT LINE-UP, BEST COST PERFORMANCE OUTLOOK FEATURES OPERATION PRINCIPLE PRODUCT LINE-UP

TF-1000 Series MINI THERMAL MASS FLOWMETER PERFECT LINE-UP, BEST COST PERFORMANCE OUTLOOK FEATURES OPERATION PRINCIPLE PRODUCT LINE-UP PERECT INE-UP, EST COST PERORMNCE T-000 Series MINI TERM MSS OWMETER OUTOOK T-000 MINI TERM MSS OWMETERS are designed and developed to offer the remote indication and control of gas flow process where

More information

Target Insertion Flowmeter

Target Insertion Flowmeter Principle of Operation Flow is measured in terms of dynamic force acting on a target (solid disk) in the flow stream. Hermetically sealed, bonded strain gages in a bridge circuit configuration mounted

More information

Size : Ends : Min Temperature : Max Temperature : Materials : Brass

Size : Ends : Min Temperature : Max Temperature : Materials : Brass Size : Ends : Min Temperature : Max Temperature : DN 3/8" to 4" Female BSP + 0 C + 90 C ( 60 C for 302 and 322 types ) Max Pressure : 16 Bars ( 10 bars for 301-302 types ) Specifications : Swing type Metal

More information

Fluoropolymer Fittings Hyper Fitting

Fluoropolymer Fittings Hyper Fitting Fluoropolymer Fittings yper Fitting Series Q S Q QR Quadruple seal construction (PT.) efore tightening Nut Tubing support Insert bushing Tubing fter tightening Quadruple sealing parts New PF ourtesy of

More information

Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,

Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax , E X - L I G H T F I T T I N G S nllk 0... 1 - W All-plastic design for Zone 2 and Zone 21/22 The explosion-protected light fittings of the series nllk 0 conform to the requirements of the ATEX-Directive

More information

DOMESTIC HOT WATER PUMPS WITH FIXED-SPEED MOTOR, 3x400V AP-, AKP- and AEP- series, threaded G1/2 G1 ¼ LOREM IPSUM JE ZULT MAAR 60 HZ.

DOMESTIC HOT WATER PUMPS WITH FIXED-SPEED MOTOR, 3x400V AP-, AKP- and AEP- series, threaded G1/2 G1 ¼ LOREM IPSUM JE ZULT MAAR 60 HZ. LOREM IPSUM JE ZULT MAAR HZ m Head m/s m/s m/s m/s m/s Ø m Ø Ø Ø Ø l/s Flow kw Shaft power P Ø m/h Ø 9 Ø Ø kw 9 Total input power P Ø DOMESTIC HOT WATER PUMPS WITH FIXED-SPEED MOTOR, xv AP-, AKP- and AEP-

More information

RFM. 300 kpa (3 bar) Return Filters RFM. Ports: 3/8 2 1/2 Flow rates: l/min

RFM. 300 kpa (3 bar) Return Filters RFM. Ports: 3/8 2 1/2 Flow rates: l/min Return Filters RFM RFM kpa (3 bar) Ports: 3/ 2 1/2 Flow rates: 0 l/min ECHNICAL DAA Max. working pressure: kpa (3 bar) Max. test pressure: 00 kpa ( bar) Bursting pressure: 1 MPa (10 bar) Fatigue test:

More information

CoriolisMaster FCB430, FCB450, FCH430, FCH450 Coriolis mass flowmeter

CoriolisMaster FCB430, FCB450, FCH430, FCH450 Coriolis mass flowmeter Data Sheet DS/FCB400/FCH400-EN Rev. D CoriolisMaster FCB430, FCB450, FCH430, FCH450 Coriolis mass flowmeter High precision measurement of mass and volume flow, density, temperature and concentration with

More information

CoriolisMaster FCB130, FCB150, FCH130, FCH150 Coriolis mass flowmeter

CoriolisMaster FCB130, FCB150, FCH130, FCH150 Coriolis mass flowmeter Data Sheet DS/FCB100/FCH100-EN Rev. D CoriolisMaster FCB130, FCB150, FCH130, FCH150 Coriolis mass flowmeter High precision measurement of mass and volume flow, density, temperature and concentration with

More information

Flow Measurement in Pipes and Ducts

Flow Measurement in Pipes and Ducts Flow Measurement in Pipes and Ducts Course No: M04-040 Credit: 4 PDH Harlan H. Bengtson, Ph.D., P.E. Continuing Education and Development, Inc. 9 Greyridge Farm Court Stony Point, NY 10980 P: (877) 322-5800

More information

EVOTRON WET ROTOR ELECTRONIC CIRCULATORS TECHNICAL DATA APPLICATIONS ADVANTAGES

EVOTRON WET ROTOR ELECTRONIC CIRCULATORS TECHNICAL DATA APPLICATIONS ADVANTAGES TECNICAL DATA EVOTRON Operating range: from, -, m3/h with head of up to metres. Pumped liquid temperature range: from - C to + C. Working pressure: bar ( kpa). Protection class: IP X. Insulation class:

More information

Pressure Measurement. Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level 2/27

Pressure Measurement. Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level 2/27 Overview Siemens AG 011 Function s are for measuring the liquid levels in wells, tanks, channels and dams. Diaphragm p Sensor U const. U + (brown) I EM I -1 (blue) 0, U B s are submersible sensors for

More information

Tap Changer Type MHF III Specification, Assembly and Materials

Tap Changer Type MHF III Specification, Assembly and Materials Tap Changer Type MHF III Specification, ssembly and Materials Descriptions General Specifications Remarks available in one, two or three phase applications shaft length available in variable sizes connection

More information

laminated on both sides for effective anchoring in the tile adhesive.

laminated on both sides for effective anchoring in the tile adhesive. Schlüter -KERDI-DRAIN Drainage floor drains for bonded waterproofing assemblies 8.2 Product data sheet Application and function Schlüter -KERDI-DRAIN is a floor drain system for the easy and reliable connection

More information

Coriolis in the Marine Industry TRICOR Coriolis Technology. All rights reserved.

Coriolis in the Marine Industry TRICOR Coriolis Technology. All rights reserved. Coriolis in the Marine Industry 1 Advantages Coriolis Meters Direct Measurement of Mass, Temp, Density Indirect measurement of Volume and Concentration (e.g. BRIX) Accuracy - high precision Swiss Watch

More information

BASE. Rotary limit switch. OptiOnS. FEAtuRES. CERtiFiCAtiOnS

BASE. Rotary limit switch. OptiOnS. FEAtuRES. CERtiFiCAtiOnS Rotary limit switch BASE Rotary limit switch used to control and measure the movement of industrial machines. Its compact size make it suitable for use in narrow spaces. FEAtuRES It consists of a gear

More information

Direct-operated 2/2-way compact solenoid valves Type EV210A

Direct-operated 2/2-way compact solenoid valves Type EV210A Data sheet Direct-operated 2/2-way compact solenoid valves Type EV210A EV210A covers a wide range of small, directoperated 2/2-way solenoid valves for use in industrial machinery. The compact design together

More information

Size : Ends : Min Temperature : Max Temperature : Materials : Brass

Size : Ends : Min Temperature : Max Temperature : Materials : Brass Size : Ends : Min Temperature : Max Temperature : DN 1/2" to 2 Free nut BSP, male or female - 10 C + 120 C Max Pressure : 20 Bars up to DN1 1/2, 16 bars over Specifications : Before or after water meter

More information

Gear Wheel Flow Meter for Viscous Fluids

Gear Wheel Flow Meter for Viscous Fluids Gear Wheel Flow Meter for Viscous Fluis measuring monitoring analysing Measuring range:. to 5 L/min Measuring accuracy: ±.3 up to ±1% of actual flow pmax: bar tmax: C rocess connection: G 1, G 3, G 1,

More information

DN 1/4" to 4" Male, Female BSP - 10 C C Max Pressure : 40 Bars Specifications : Anti blow-out stem PTFE packing Full bore.

DN 1/4 to 4 Male, Female BSP - 10 C C Max Pressure : 40 Bars Specifications : Anti blow-out stem PTFE packing Full bore. Size : Ends : Min Temperature : Max Temperature : DN 1/4" to 4" Male, Female BSP - 10 C + 120 C Max Pressure : 40 Bars Specifications : Anti blow-out stem PTFE packing Full bore Materials : Brass Page

More information

Odor Removal Filter Series AMF

Odor Removal Filter Series AMF Odor Removal Filter Series AMF Series AMF Odor Removal Filter efficiently removes odor in compressed air with an activated carbon element. The unit is designed for use in food processing, pharmaceutical,

More information

PIOX / Analytical Measuring & Sales Methods. FLEXIM GmbH

PIOX / Analytical Measuring & Sales Methods. FLEXIM GmbH PIOX / Analytical Measuring & Sales Methods PIOX - Process Analyzers PIOX S Non-intrusive Ultrasonic Measurement Concentration Mass Flow Density HCL Nitric Acid Sulfuric Acid PIOX R - Process Refract meter

More information

ATEX/IECEx RTD temperature probe

ATEX/IECEx RTD temperature probe Page 1/8 ATEX/IECEx RTD temperature probe with connecting cable acc. to DIN EN 60751 For temperatures from -100 to +600 C As single, double, or triple RTD temperature probe In two-wire, three-wire, or

More information

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm DMP Pi Precision Pressure Transmitter pressure ports and process connections with flush welded stainless steel diaphragm accuracy according to IEC 600: 0, % FSO Nominal pressure from 0... 00 mbar up to

More information

A wide selection of pipe and orifice sizes is offered. Valves are available with threaded ports in brass and stainless steel.

A wide selection of pipe and orifice sizes is offered. Valves are available with threaded ports in brass and stainless steel. Solenoid Valve Waterhammer-Free, 0- PSI /-Way; NPT - NPT; 0- PSI Advantages/Benefits Type 63 Waterhammer-free Low noise Zero differential pressure ompact design with high flow rates Low maintenance oil

More information

S E G N A L F E IP P

S E G N A L F E IP P 9 8 PIPE FLANGES an excellence in engineering www.jbj.co.uk/ portflanges.html SAE standard, and 6, series flanges for screw or weld connection. Available for straight connection, fixed or swivel elbow

More information

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm DMP Pi Precision Pressure Transmitter pressure ports and process connections with flush welded stainless steel diaphragm accuracy according to IEC 600: 0, % FSO Nominal pressure from 0... 00 mbar up to

More information

General Specifications

General Specifications General Specifications GS 1F24-E Model YF Vortex Flowmeters (Style E) These YF Vortex Flowmeters measure process fluid flow by measuring the rate at which vortices are shed from a shedder in the process

More information

G-FIRE GROOVED FITTINGS

G-FIRE GROOVED FITTINGS G-FIRE GROOVED FITTINGS 29 Pictorial Table of Contents Figure 510 90 Cast Elbows Page 32 Figures 212 & 312 22 1 2 Elbows Page 35 Figure 501 45 Cast Elbows Page 32 Figures 211 & 311 11 1 4 Elbows Page 36

More information

Direct-operated 2/2-way solenoid valves Type EV210B

Direct-operated 2/2-way solenoid valves Type EV210B Data sheet Direct-operated 2/2-way solenoid valves Type EV20B EV20B covers a wide range of direct-operated 2/2-way solenoid valves for universal use. EV20B is a very robust valve program with high performance

More information

Tecnología en Electrónica y Control SRL Ficha Técnica

Tecnología en Electrónica y Control SRL Ficha Técnica Tecnología en Electrónica y Control SRL Ficha Técnica Caudalímetros Tecnología en Electrónica y Control SRL Oficina Central Wüthrich 949 San Carlos Centro (S3013DES) / Santa Fe / Argentina Tel./Fax/Líneas

More information

AIR BREATHER FILTERS. Temperature from -25 C to +100 C

AIR BREATHER FILTERS. Temperature from -25 C to +100 C IR RETHER FILTERS The comprehensive series of breather filters makes it possible to meet all market demands. Metal and plastic styles suitable for use on mobile equipment are available. The function of

More information

Body (Black) O-ring Stud. Effective when piping in a confined space. The body and the threaded portion can rotate (For positioning to some extent).

Body (Black) O-ring Stud. Effective when piping in a confined space. The body and the threaded portion can rotate (For positioning to some extent). Antistatic One-touch Fittings Tubing: Metric Size/Connection Thread: M, Rc, G, NPT, NPTF Series KA RoS One-touch fitting with antistatic prevention. One-touch IN/OUT connection. Possible to use from vacuum

More information

Sizing Thermowell according to ASME PTC 19.3

Sizing Thermowell according to ASME PTC 19.3 Products Solutions Services Sizing Thermowell according to ASME PTC 19.3 AIS 2015 17th September Endress+Hauser Pessano c. Bornago Slide 1 SUMMARY Why is stress thermowell calculation necessary? Loading

More information

FMP :41 Pagina 5 (1,1) FMP

FMP :41 Pagina 5 (1,1) FMP FMP 6-07-006 9:4 Pagina 5 (,) FMP 6 FMP 6-07-006 9:4 Pagina 5 (,) SERIES FMP Working pressure 80 bar Style S Style Style T Style D Style V Style Z 7 FMP 6-07-006 9:4 Pagina 7 (,) Technical data Filter

More information

ME411 Engineering Measurement & Instrumentation. Winter 2017 Lecture 11

ME411 Engineering Measurement & Instrumentation. Winter 2017 Lecture 11 ME411 Engineering Measurement & Instrumentation Winter 2017 Lecture 11 1 Flow Measurement Identify an effect that depends on flow rate Process control requires accurate measurement of flow control Mixing

More information

Solenoid valves 2/2-way direct-operated type EV210A

Solenoid valves 2/2-way direct-operated type EV210A MAKING MODERN LIVING POSSIBLE Data sheet Solenoid valves 2/2-way direct-operated type EV210A EV210A covers a wide range of small, direct-operated 2/2-way solenoid valves for use in industrial machinery.

More information

ULTRA OVAL Meter Sizes:39, 41, 45, 50, 52, 53 w/unfactored Pulse Generator (NPG60A)

ULTRA OVAL Meter Sizes:39, 41, 45, 50, 52, 53 w/unfactored Pulse Generator (NPG60A) ULTRA OVAL Meter Sizes:9, 4, 45, 50, 5, 5 w/unfactored Pulse Generator (NPG60A) GENERAL SPECIFICATION GS.No.GBU0--E GENERAL ULTRA OVAL MODEL 9, 4, and45 provides extensive capability as a highly dependable

More information

CHE-201. I n t r o d u c t i o n t o Chemical E n g i n e e r i n g. I N S T R U CTOR: D r. N a b e e l S a l i m A b o - Ghander.

CHE-201. I n t r o d u c t i o n t o Chemical E n g i n e e r i n g. I N S T R U CTOR: D r. N a b e e l S a l i m A b o - Ghander. I n t r o d u c t i o n t o Chemical E n g i n e e r i n g CHE-201 I N S T R U CTOR: D r. N a b e e l S a l i m A b o - Ghander C h a p t e r 3 Processes and Process Variables Introduction What is a process?

More information

PTFE. Laboratory Products

PTFE. Laboratory Products PTFE Laboratory Products PTFE STIRRER BARS 23 Micro Stirrer Bars are for the very smallest containers. Note: Always use the largest stirrer bar possible. Ref No. L (mm) Ø (mm) 001.802

More information

Given Find Water Properties

Given Find Water Properties Venturi Example Given: A venturi is to be used to measure a 50 gpm flow of 70 F water in a 4-in ID pipe. Find: Select a throat diameter that provides Re d > 00,000 in the throat, and determine what differential

More information

Pressure transmitters for industrial applications MBS 32 and MBS 33

Pressure transmitters for industrial applications MBS 32 and MBS 33 Data sheet Pressure transmitters for industrial applications MBS 32 and MBS 33 The standard pressure transmitters MBS 32 and MBS 33 are designed for use in almost all industrial applications, and offer

More information