Thermostatic Expansion Valves

Size: px
Start display at page:

Download "Thermostatic Expansion Valves"

Transcription

1 January / ULLETIN 0-0 Expansion Valves featuring Selective harges

2 Page / ULLETIN 0-0 THERMOSTTI EXPNSION VLVES SELETIVE THERMOSTTI HRGES Designed to provide optimum perfmance f all applications air conditioning and heat pump, medium and low temperature refrigeration. THERMOSTTI ELEMENT DESIGN Long lasting and field proven stainless steel diaphragm and welded element construction. DIPHRGM DESIGN Large flat diaphragm permits precise valve control. REPLELE THERMOSTTI ELEMENTS Field replaceable elements on all standard valves. 0 Outstanding Features & enefits of Splan Expansion Valves LNED PORT DESIGN Provides perfect pin and pt alignment, and prevents changes in pressure drop across the valve from influencing valve operation. Provides excellent control on applications with widely varying operating conditions. PIN RRIER DESIGN (ONVENTIONL VLVES) Provides precise pin and pt alignment, and tighter seating. ESSILE INTERNL PRTS Durable, leakproof body joint construction allows the valve to be disassembled, and the internal parts cleaned and inspected. MTERILS OF ONSTRUTION Pin and pt materials offer maximum protection against crosion and erosion. SILVER SOLDERED ONNETIONS F leakproof, high strength connection-to-body joints. DJUSTLE SUPERHET DESIGN ll standard valves are externally adjustable except the Type NI, which is internally adjustable through its outlet connection. TLE OF ONTENTS Selection Procedure Valve Nomenclature / Ordering Instructions.. Recommended harges TEV apacity Ratings f Refrigerants:,, a, 0, 0, 0, 0, 0, 0, 0, 0, 0, and apacity Tables f Refrigerants:,, a, 0, 0, 0, 0, 0, 0, 0, 0, 0, and TEV Quick Reference Guide Valve Specifications NI RIVE F & EF Q, EQ, & SQ G EG F SF & EF S ES O H M V W D Materials and Details of onstruction OEM Type Expansion Valves..... Pressure-Temperature hart Refer to ulletin 0- f a complete discussion on The They of Operation and pplication of Expansion Valves. Refer to ulletin 0- f a complete discussion on Installing and Servicing Expansion Valves. SPORLN THERMOSTTI EXPNSION VLVES The thermostatic expansion valve (TEV) controls the flow of liquid refrigerant entering the direct expansion (DX) evapat by maintaining a constant superheat of the refrigerant vap at the outlet of the evapat. The TEV controls the difference between the actual temperature and the saturation temperature of the refrigerant cresponding to the suction pressure at the sensing bulb location; this is superheat. y controlling superheat, the TEV keeps nearly the entire evapat surface active, while preventing liquid refrigerant from returning to the compress. The ability of the TEV to match refrigerant flow to the rate at which refrigerant can be vapized in the evapat makes the TEV the ideal expansion device f most air conditioning and refrigeration applications. FOR USE ON REFRIGERTION and/ IR ONDITIONING SYSTEMS ONLY ulletin 0-0, January supersedes ulletin 0-0, December ; ulletin 0-, February and all pri publications. OPYRIGHT Y SPORLN VLVE OMPNY, WSHINGTON, MISSOURI

3 The following procedure should be used when selecting a Splan TEV:. Determine the liquid temperature of the refrigerant entering the valve The TEV capacity tables on pages to are based on a liquid temperature of 00 F f R-, R-, R-a, R0, R-0, R-0, R-0, R-0, R-0, R-0, R-0, R-0; R- (ammonia) capacities are based on F. F other liquid temperatures, apply the crection fact given in the tables f each refrigerant. F example see Table.. Determine pressure drop across valve The pressure drop crection facts are based on standard liquid temperature and pressure drop. The standard pressure drop is dependent on the evapat temperature. To determine the pressure drop, subtract the saturated pressure equivalent to evapat outlet temperature from the condensing pressure. The condensing pressure used in this calculation should be the minimum operating condensing pressure of the system. From this value, subtract all other pressure losses to obtain the net pressure drop across the valve. Use this value to determine the pressure drop crection fact. F example see Table. e sure to consider all of the following possible sources of pressure drop:. Friction losses through refrigeration lines including the evapat and condenser.. Pressure drop across liquid line accessies such as a solenoid valve and filter-drier.. Static pressure loss (gain) due to the vertical lift (drop) of the liquid line.. Pressure drop across a refrigerant distribut if used. Refer to ulletin 0-0 f infmation on refrigerant distributs.. Select valve from the capacity tables Select a valve based on the design evapating temperature. If possible the valve capacity should be equal slightly exceed the design rating of the system. e sure to apply the appropriate crection facts f liquid temperature and pressure drop. Once the desired valve capacity has been located, determine the nominal capacity of the valve from the tables second column. On multiple evapat systems, select each valve on the basis of individual evapat capacity. F example see Table.. Determine if an external equalizer is required The amount of pressure drop between the valve outlet and bulb location will determine if an external equalizer is required. Refer to ulletin 0- f further infmation on this subject. THERMOSTTI EXPNSION VLVE PITIES f S VLVE S TONS OF REFRIGERTION IR ONDITIONING, HET PUMP and NOMINL PITY REOMMENDED THERMOST V, VP00, VG VZ, VZP0 EVPORTOR TEMPERTURE F-EF-G-EG / NI / F-EF-G-EG / NI-F-EF-G-EG / G-EG / NI-F-EF-G-EG SELETION PROEDURE Table The valve capacity should equal slightly exceed the tonnage rating of the system. (F complete R- capacity tables, see page ) ULLETIN 0-0 / Page. Select body type Select the body type accding to the style connections desired. F complete specifications on each TEV type including nominal ratings, refer to pages to.. Select the Splan Selective harge Select the charge accding to the design evapating temperature from the Table on Page. Refer to ulletin 0- f a complete discussion of the available Splan Selective harges. Selection Example Refrigerant pplication: medium temperature refrigeration Design evapat temperature F Design condenser temperature F Refrigerant liquid temperature F Design system capacity ton vailable pressure drop across TEV: ondensing pressure (psig) Evapating pressure (psig) Liquid line and accessies loss (psi).... Distribut and tubes loss (psi) Q Refrigerant liquid crection fact Pressure drop crection fact Use the following fmula to calculate TEV capacity: TEV apacity = TEV rating x F liquid temperature x F pressure drop EGVE- Has valve capacity of:.0 x. x 0. =. Tons at 0 F evapating temperature, 00 psi pressure drop and 0 liquid temperature. charge (from Table on Page ): V W Selection: EGVE-- / x / x / ODF x Q n externally equalized valve must be used on evapats employing a refrigerant distribut due to the pressure drop created by the distribut. In addition, an externally equalized valve should always be used with air conditioning thermostatic charges to reduce the possibility of thermostatic charge migration. W Please note that the refrigerant charge designation in the thermostatic charge ( V in this case) is dropped when it is incpated into the valve model designation. Design Evapating Temperature EVPORTOR TEMPERTURE (F ) 0 0 & 0 0 & 0 0 LIQUID TEMPERTURE ENT ORRETION FTOR TEV Pressure Drop Liquid Temperature PRESSURE DROP ROSS TEV (PSI) ORRETION FTOR, F PRESSURE DR Table Table

4 Page / ULLETIN 0-0. Valve Nomenclature / Ordering Instructions ombine the letters and numbers in the following manner to obtain the complete valve designation. lso include all connection sizes and the capillary tube length. EXMPLE EG V E - - ody Type F E V G M J X L S S p lan ode Element Label ol ode - R- - Yellow - R- - lue - R- - Green - R- - lue - R- - lue - R-a - lue - R-0 - Pink - R-0 - Sand - R-0 - Orange PPLITION IR ONDITIONING OMMERIL REFRIGERTION 0 F to 0 F LOW TEMPERTURE REFRIGERTION 0F to 0 F EXTREME LOW TEMP. REFRIGERTION 0 F to 00 F V N R F R W P W - R-0 - Green - R-0 - Lt. rown - R-0 - Purple - R-0 - Yellow - R-0 - Purple - R-0 - lue - R-0 - Teal - R-0 - lue - R- - White "E" specifies external equalizer. Omission of letter "E" indicates valve with internal equalizer. eg. EGV-- Nominal apacity in Tons harge /" ODF Solder Inlet onnection Size and Style * REOMMENDED THERMOSTTI HRGES X /" ODF Solder Outlet onnection Size and Style X /" ODF Solder onnection Size and Style SPORLN SELETIVE HRGES ENGINEERED f PEK PERFORMNE f EH SPEIFI PPLITION TUL THERMOSTTI 0 0 a HRGES F P0 JP0 X P0 FP0 V P00 N P00 VP00 V G N G VG S P R P RP F J X F V N V S R R L P P, L, L F Z FZ F ZP FZP V Z VZ V ZP0 VZP0 LZ S Z RZ P Z RZ LZP S ZP RZP P ZP RZP Z, L Z, L V X VX LX S X RX P X RX * PPLITION FTORS:. The Type ZP charges have essentially the same characteristics as the Type Z charge with one exception: they produce a pressure limit Maximum Operating Pressure (MOP). ZP charges are not intended as replacements f Z charges. Each should be selected f its own unique purpose. Refer to ulletin 0- f additional application discussion.. ll air conditioning and heat pump charges are intended f use with externally equalized valves. Refer to ulletin 0- f complete discussion on when to use an external equalizer.. Type L Liquid charges are also available f most commonly used refrigerants in most element sizes.. Refer to ulletin 0- f infmation regarding the differences between the VG and VP00 charges.. If in doubt as to which charge to use, review the section on thermostatic charges in ulletin 0- contact Splan Valve ompany, Washington, Missouri with complete system data. TEV PITY RTINGS FOR S:,, a, 0, 0, 0, 0, 0, 0, 0, 0, 0, TEV capacity ratings f R-, R-, R-a, R-0, R-0, R-0, R-0, R-0, R-0, R-0, R-0, R-0 are based on vap free 00 F liquid refrigerant entering the expansion valve, a maximum opening superheat of F, and a standard facty air test superheat setting. discussion of the relationship between valve capacities and superheat settings can be found in ulletin 0-. The ratings f evapat temperatures 0 F, 0 F, -0 F, -0 F in the capacity tables are in accdance with NSI/RI Standard Number 0. TEVs are tested in accdance with NSI/SHRE. X ' apillary Tubing Length (Inches Feet) TEV models featuring the mechanical pressure limit style thermostatic elements, i.e., the Types G(PL) and (PL) TEVs, are now obsolete. onsult ulletin 0-0- f additional infmation on this subject and replacement valves. R- (ammonia) capacities f Types D and TEVs are shown on Page. These ratings are based on vap free F liquid refrigerant entering the TEV, a maximum opening superheat of F, and a standard facty air test setting. F TEV capacity ratings at operating conditions not shown in the following tables, contact Splan Valve ompany.

5 ULLETIN 0-0 / Page THERMOSTTI EXPNSION VLVE PITIES f S TONS OF REFRIGERTION, a, 0, 0 IR ONDITIONING, HET PUMP and OMMERIL REFRIGERTION PPLITIONS a 0 0 VLVE S NOMINL REOMMENDED THERMOSTTI HRGES PITY F, FP0 J, JP0 X, XP0 F, FP0 EVPORTOR TEMPERTURE ( F) NI-F-EF-G-EG / F-EF-G-EG / NI-F-EF-G-EG / NI-F-EF-G-EG / NI-F-EF-G-EG F-EF-G-EG -/ F&EF(Ext)-G&EG(Ext)-(Int)-S S -/ S &S(Ext) S(Ext) H -/ H H H H H M M M LNED PORT THERMOSTTI EXPNSION VLVES F-EF-SF F-EF-SF F-EF-SF F-EF-SF F-EF-SF ES ES O O O O O O V V V W W 0 V LVE RTRIDGE NO. REPLELE RTRIDGE THERMOSTTI EXPNSION VLVES 0 / / / / / LIQUID TEMPERTURE ENTERING TEV ( F) ORRETION FTOR, F LIQUID TEMPERTURE a These facts include crections f liquid refrigerant density and net refrigerating effect and are based on an evapat temperature of 0 F. However, they may be used f any evapat temperature from 0 F to 0 F since the variation in the actual facts across this range is insignificant. EVPORTOR PRESSURE DROP ROSS TEV (PSI) TEMPERTURE ( F) ORRETION FTOR, F PRESSURE DROP & TEV capacity = TEV rating x F liquid temperature x F pressure drop Example: ctual capacity of a nominal -/ ton R-a Type EG valve at 0 F evapat, 00 psi pressure drop across the TEV, and 0 F liquid temperature entering the TEV =. (from rating chart) x. (F liquid temperature) x. (F pressure drop) =. tons.

6 Page / ULLETIN 0-0, 0, 0 THERMOSTTI EXPNSION VLVE PITIES f S TONS OF REFRIGERTION VLVE S IR ONDITIONING, HET PUMP and OMMERIL REFRIGERTION PPLITIONS NOMINL PITY 0 0 REOMMENDED THERMOSTTI HRGES V, VP00, VG VZ, VZP0 V, VP00, VG VZ, VZP0 N, NP00, NG EVPORTOR TEMPERTURE ( F) F-EF-G-EG / NI / F-EF-G-EG / NI-F-EF-G-EG / G-EG / NI-F-EF-G-EG F-EF-G-EG -/ F&EF(Ext)-G&EG(Ext)-S F&EF(Int)-G&EG(Int) -/ F&EF(Ext)-G&EG(Ext)-(Int)-S S S &S(Ext) S(Ext) H -/ H -/ H H H H M M M M LNED PORT THERMOSTTI EXPNSION VLVES F-EF-SF F-EF-SF F-EF-SF F-EF-SF F-EF-SF ES ES O O O O O O V V V W W 0 0 V LVE RTRIDGE NO. REPLELE RTRIDGE THERMOSTTI EXPNSION VLVES 0 / / / / / VG and NG harges Only -- RIVE RIVE RIVE RIVE LIQUID TEMPERTURE ENTERING TEV ( F) ORRETION FTOR, F LIQUID TEMPERTURE These facts include crections f liquid refrigerant density and net refrigerating effect and are based on an evapat temperature of 0 F. However, they may be used f any evapat temperature from -0 F to 0 F since the variation in the actual facts across this range is insignificant. EVPORTOR PR ESSURE DROP ROSS TEV (PSI) TEMPERTURE (F ) ORRETION FTOR, F PRESSURE DROP & & TEV capacity = TEV rating x F liquid temperature x F pressure drop Example: ctual capacity of a nominal ton R- Type S valve at 0 F evapat, 00 psi pressure drop across the TEV, and 0 F liquid temperature entering the TEV =. (from rating chart) x.0 (F liquid temperature) x 0. (F pressure drop) =.0 tons.

7 ULLETIN 0-0 / Page THERMOSTTI EXPNSION VLVE PITIES f S TONS OF REFRIGERTION 0, 0, 0 IR ONDITIONING, HET PUMP and OMMERIL REFRIGERTION PPLITIONS VLVE S NOMINL REOMMENDED THERMOSTTI HRGE PITY S, SP SZ, SZP R, RP RZ, RZP R, RP RZ, RZP EVPORTOR TEMPERTURE ( F) NI-F-EF-G-EG / F-EF-G-EG / NI-F-EF-G-EG / NI-F-EF-G-EG / NI-F-EF-G-EG F-EF-G-EG -/ F&EF(Ext)-G&EG(Ext)-(Int)-S S S &S(Ext) S(Ext) H -/ H H H -/ H H M M M M LNED PORT THERMOSTTI EXPNSION VLVES F-EF-SF F-EF-SF F-EF-SF F-EF-SF F-EF-SF ES ES -/ O O O O O O V V V V LVE RTRIDGE NO. REPLELE RTRIDGE THERMOSTTI EXPNSION VLVES 0 / / / / LIQUID TEMPERTURE ENTERING TEV ( F) ORRETION FTOR, F LIQUID TEMPERTURE These facts include crections f liquid refrigerant density and net refrigerating effect and are based on an evapat temperature of 0 F. However, they may be used f any evapat temperature from -0 F to 0 F since the variation in the actual facts across this range is insignificant. EVPORTOR PR ESSURE DROP ROSS TEV (PSI) TEMPERTURE (F ) ORRETION FTOR, F PRESSURE DROP & & TEV capacity = TEV rating x F liquid temperature x F pressure drop Example: ctual capacity of a nominal -/ ton R-0 Type EG valve at -0 F evapat, psi pressure drop across the TEV, and 0 F liquid temperature entering the TEV =. (from rating chart) x. (F liquid temperature) x 0. (F pressure drop) =. tons.

8 Page / ULLETIN 0-0 THERMOSTTI EXPNSION VLVE PITIES f S TONS OF REFRIGERTION 0 & 0 OMMERIL and LOW TEMPERTURE REFRIGERTION PPLITIONS 0 0 VLVE S NOMINL REOMMENDED THERMOSTTI HRGE PITY L LZ, LZP P PZ, PZP EVPORTOR TEMPERTURE ( F) NI-F-EF-G-EG / F-EF-G-EG / NI-F-EF-G-EG / NI-F-EF-G-EG / NI-F-EF-G-EG F-EF-G-EG -/ F&EF(Ext)-G&EG(Ext)-(Int)-S S S &S(Ext) S(Ext) H -/ H H H -/ H H M M M M LNED PORT THERMOSTTI EXPNSION VLVES F-EF-SF F-EF-SF F-EF-SF F-EF-SF F-EF-SF ES ES -/ O O O O O O V V V V LVE RTRIDGE NO. REPLELE RTRIDGE THERMOSTTI EXPNSION VLVES Q-SQ-EQ 0 / Q-SQ-EQ / Q-SQ-EQ / Q-SQ-EQ Q-SQ-EQ -/ Q-SQ-EQ Q-SQ-EQ LIQUID TEMPERTURE ENTERING TEV ( F) ORRETION FTOR, F LIQUID TEMPERTURE These facts include crections f liquid refrigerant density and net refrigerating effect and are based on an evapat temperature of 0 F. However, they may be used f any evapat temperature from -0 F to 0 F since the variation in the actual facts across this range is insignificant. EVPORTOR PR ESSURE DROP ROSS TEV (PSI) TEMPERTURE (F ) ORRETION FTOR, F PRESSURE DROP & & TEV capacity = TEV rating x F liquid temperature x F pressure drop Example: ctual capacity of a nominal -/ ton R-0 Type EG valve at -0 F evapat, psi pressure drop across the TEV, and 0 F liquid temperature entering the TEV =. (from rating chart) x. (F liquid temperature) x 0. (F pressure drop) =. tons.

9 ULLETIN 0-0 / Page THERMOSTTI EXPNSION VLVE PITIES f S TONS OF REFRIGERTION (mmonia) VLVE D NOMINL PITY REOMMENDED THERMOSTTI VLVE NOMINL REOMMENDED THERMOSTTI HRGE PITY HRGE, L Z, L Z L EVPORTOR TEMPERTURE ( F) EVPORTOR TEMPERTURE ( F) LIQUID TEMPERTURE ENTERING TEV ( F) ORRETION FTOR, F LIQUID TEMPERTURE EVPORTOR PRESSURE DROP ROSS TEV (PSI) TEMPERTURE (F ) ORRETION FTOR, F PRESSURE DROP & OMMERIL REFRIGERTION PPLITIONS These facts include crections f liquid refrigerant density and net refrigerating effect and are based on an average evapat temperature of 0 F. However, they may be used f any evapat temperature from -0 F to 0 F since the variation in the actual facts across this range is insignificant. TEV capacity = TEV rating x F liquid temperature x F pressure drop Example: ctual capacity of a nominal ton R- Type D valve at F evapat, 00 psi pressure drop across the TEV, and 0 F liquid temperature entering the TEV =.00 (from rating chart) x.0 (F liquid temperature) x 0. (F pressure drop) =. tons. NI RI F EF VLVE Specs on Page Specs on Page Specs on Page & Specs on Page & TEV NOMINL PITY RNGE (tons) R- / / / R-a / R-0 & R-0 / / / / / Quick ONNETION S SE Flare SE Flare ODF Solder SE Flare ODF Solder Reference Guide VLVE DESRIPTION ND PPLITION Small brass body, angle style valve which is adjustable through its outlet fitting. Inlet connection has a removable 00 mesh strainer. Suitable f small capacity refrigeration applications in which an external adjustment is not required. Typical application: Drink dispensers, ice cubers. Small brass body, externally adjustable valve available only f R- air conditioning heat pump applications. This valve is available with the Rapid Pressure alancer (RP) feature f off-cycle pressure equalization if desired. Suitable f replacing OEM type TEVs used on these applications. Small brass bar body, externally adjustable valve f small capacity refrigeration systems. SE flare inlet connection has a removable 00 mesh strainer. Typical applications: Refrigerated cases, coolers, freezers. Same as the Type F valve except it features ODF solder connections. The inlet connection has a 00 mesh insert type strainer. Typical applications: Refrigerated cases, coolers, freezers. FOR OEM VLVES, REFER TO PGE.

10 Page 0 / ULLETIN 0-0 Q Specs on Page - EQ Specs on Page - SQ G Specs on Page - EG F SF VLVE Specs on Page 0 Specs on Page Specs on Page Specs on Page Specs on Page & EF Specs on Page & TEV NOMINL PITY RNGE (tons) R- / / / / / R-a / -/ / -/ / -/ / / R-0 & R-0 / / / / / Quick ONNETION S SE Flare Extended ODF Solder Extended ODF Solder SE Flare ODF Solder SE Flare SE Flare Extended ODF Solder Extended ODF Solder Reference Guide FOR OEM VLVES, REFER TO PGE. VLVE DESRIPTION ND PPLITION The brass body Q valve is externally adjustable. The valve body has a removable cartridge ifice. The valve body, cartridge and thermostatic element can be supplied as independent components. This allows body, cartridge and element to be assembled and matched to specific system requirements. Inlet connection has a 00 mesh removable strainer screen. Typical applications: Refrigeration applications and external equalized versions may be used on air conditioning. Same as the Type Q valve except it features extended ODF connections. 00 mesh insert strainer is provided with the valve. Same as the Type Q valve except it features ODF solder connections and a fged brass inlet fitting with a removable 00 mesh strainer screen which can be cleaned and/ replaced without removing the valve from the line. Fged brass body, externally adjustable valve f small capacity refrigeration systems. Inlet connection has a removable 00 mesh strainer. Typical applications: Refrigerated cases, coolers, freezers, small capacity air conditioners. Same as the Type G valve except it features ODF solder connections and a fged brass inlet fitting with a removable 00 mesh strainer which can be cleaned and/ replaced without removing the valve from the line. Fged brass body, externally adjustable valve. Inlet connection has a removable 0 mesh strainer. This valve is a larger capacity version of the Type G valve. Typical applications: Refrigerated cases, coolers, freezers, air conditioners. Same physical size as the Type F valve with SE flare connections except it features a balanced pt construction. Inlet connection has a removable 00 mesh strainer. Typical applications: Small capacity refrigeration that operates over widely varying operating conditions. Same as the Type F valve except it features ODF solder connections and a fged brass inlet fitting with a removable 00 mesh strainer which can be cleaned and/ replaced without removing the valve from the line. Same as the Type F valve except it features extended ODF connections. 00 mesh insert strainer is provided with the valve.

11 S ES O VLVE Specs on Page Specs on Page Specs on Page & H M V W D Specs on Page 0 Specs on Page Specs on Page Specs on Page Specs on Page Specs on Page TEV NOMINL PITY RNGE (tons) R- 0 & 0 -/ 0 00 & 0 R-a & 0 -/ 0 & 0 R- R R-0 & R-0 & -/ -/ 0 0 Quick ONNETION S ODF Solder Extended ODF Solder ODF Solder ODF Solder FPT Flange ODF Solder FPT Flange ODF Solder FPT Flange ODF Solder Flange FPT Socket Weld Flange FPT Socket Weld Flange Reference Guide ULLETIN 0-0 / Page VLVE DESRIPTION ND PPLITION rass bar body, externally adjustable valve. Inlet has a permanent mesh strainer. General purpose valve f air conditioning and refrigeration applications. Same physical size as the Type S valve except it features extended ODF connections and a balanced pt construction. rass bar body, externally adjustable valve. Inlet has a permanent mesh strainer. This valve features a balanced pt construction, and it is suitable f both air conditioning and refrigeration applications. rass bar body, externally adjustable valve with flange connections. Inlet flange bushing has a permanent mesh strainer. The FPT flange connection requires the K- adapter kit. This valve provides the smallest capacity TEVs with flange connections and it is suitable f both air conditioning and refrigeration applications. ast bronze body, externally adjustable valve with flange connections. Inlet has a mesh strainer. This valve type provides valve capacities greater than the Type H and it is suitable f air conditioning and refrigeration applications. Flanges f the Type M valve are interchangeable with the Type V valve. ast bronze body, externally adjustable valve with flange connections. Inlet has a mesh strainer. This valve type features a dual pt semi-balanced design. This valve type provides valve capacities greater than the Type M, and is suitable f air conditioning and refrigeration applications. Flanges f the Type V are interchangeable with the Type M. ast bronze body, externally adjustable valve with flange connections. Inlet has a mesh strainer. This valve type features a dual pt semi-balanced design and it is primarily f large capacity chillers. This valve type provides the largest valve capacities available f flange connection TEVs. Gray cast iron body, externally adjustable valve f small capacity ammonia service. Optional XD-0 00 mesh external strainer may be dered with this valve. Gray cast iron body, externally adjustable valve f large capacity ammonia service. Optional 00 (/ FPT) 00 (/ FPT) 0 mesh external strainer may be dered with this valve. FOR OEM VLVES, REFER TO PGE.

12 Page / ULLETIN 0-0 f Refrigerants -a-0-0 SE Flare onnections Splan Type NI valve is a small brass bar body, angle style (bottom outlet) valve with SE flare connections. The thermostatic element is replaceable, and the inlet connection has a removable 00 mesh strainer. n internal adjustment is provided in the outlet fitting, and adjustments can be made with a / hex wrench when the outlet is not connected. This valve is designed f small refrigeration systems such as drink dispensers and ice cubers where space is limited and an external superheat adjustment is not necessary. ( Splan o de) (V) 0 (N) 0 (V) a (J) (F) 0 (X) 0 (F) 0 (S) 0 (R) 0 (R) 0 (P) 0 (L) Internal Only SPEIFITIONS NOMINL PITY Tons of Refrigeration NIV-/ / NIV-/ / NIV- NIJ-/ / NIJ-/ / harges vailable Z ZP0 ELEMENT SIZE NO., KNIFE EDGE JOINT Standard Tubing Length-Inches ONNETIONS Inches SE Flare lue figures are standard and will be furnished unless otherwise specified. INLET / / Q / / Q NIJ-/ / NIJ- / / Q NIS-/ / 0 NIS-/ / / / Q Z NIS-/ / ZP NIS- / / Q NIP-/ / NIP-/ / / / Q Z NIP-/ / ZP NIP- / / Q Q The / SE inlet fitting has a long taper on the flare surface. / x / reducing flare nut will allow / OD tubing to be attached to this fitting. W The / SE outlet fitting has a long taper. / OD tubing can be connected by using / x / reducing flare nut.. f complete details of construction, see page OUTLET Net Shipping / / W -/ DIMENSIONS Inches onnections - SE Flare OUTLET FITTING SIZE /.0. /.. UL SIZES Inches STNDRD HRGES a OD x.00 Z & ZP Series 0.0 OD x OD x.00 Removable / SE Inlet P/N / SE Inlet P/N NOTE: The cross-sectional views on the following valve specification pages illustrate the internal construction differently depending on whether one two pushrod construction is used. Types NI, RIVE, F, EF, Q, EQ, SQ, G, EG,, S, H, M, D, and utilize two pushrods to operate the valve. The pushrods are not shown to avoid confusing details in the cross-sectional view. The element diaphragm assembly deflects in response to temperature changes at the sensing bulb. This moves the pin carrier which opens the valve pt. The pushrods transmit the diaphragm motion to the pin carrier. Valve types F, EF, SF, ES, O, V, and W utilize only one pushrod. The pushrods are shown in the proper position.

13 ( Splan o de) (V) 0 (N) 0 (V) f Refrigerant SE Flare & ODF Solder onnections f complete details of construction, see page Only SPEIFITIONS RIVE- RIVE- RIVE- RIVE- Splan Type RI valve is a small brass bar body, externally adjustable valve available with either SE flare ODF solder connections. This valve has a replaceable thermostatic element, and it is designed f small R- air conditioning and heat pump units where space is limited. This valve is also ideal f replacement of OEM type Splan TEVs such as the Type I and I when used on the above applications. This valve is available with the Rapid Pressure alancer (RP) feature f off-cycle pressure equalization if desired. Refer to Splan ulletin 0- f additional infmation on this subject. Refrigerant distributs that will mate directly to this valve are listed below. Refer to Splan ulletin 0-0 f additional application infmation on this subject. R NOMINL PITY Tons of Refrigeration Outlet onnections / SE / ODF / ODF harges vailable G only ELEMENT SIZE NO., KNIFE EDGE JOINT Standard Tubing Length-Inches 0 Distributs 0, 0, 0, 0, 0(R), 0,, (R) INLET ONNETIONS Inches lue figures are standard and will be furnished unless otherwise specified. SE Flare E ODF Solder OUTLET INLET OUTLET / / / / / / / /, / ULLETIN 0-0 / Page Net Shipping -/ E ODF Solder indicates a female connection on the valve of proper diameter to receive copper tubing of cresponding OD size. Thus / ODF will receive / OD tubing. R The Nominal apacity of the valve is increased by % when the Rapid Pressure alancer (RP) feature is used. cross drilling is part of the internal construction of the RP feature and this drilling provides the additional refrigerant flow. SE Flare. ODF Solder.. RP Model DIMENSIONS Inches FITTING SIZE / SE. / SE..0 / ODF.. / ODF... / ODF..0 TOP VIEW 0 / ODF onnection. ODF Solder. SE Flare

14 Page / ULLETIN 0-0 & f Refrigerants -a-0-0 SE Flare & ODF Solder onnections Splan Type F with SE flare connections Type EF with ODF solder connections are small brass bar body valves with identical internal construction and replaceable thermostatic elements. The Type F valve has a removable 00 mesh strainer as a standard feature. The Type EF has a 0x0 mesh insert strainer. These valves are designed f small refrigeration systems such as refrigerated cases, coolers, and freezers where space is limited and an external adjustment is desired. Refrigerant distributs that will mate directly to this valve are listed below. Refer to Splan ulletin 0-0 f additional application infmation on this subject. F Outlet onnections / SE / ODF Distributs 0, 0, 0, 0, 0(R), f complete details of construction, see page EF ( Splan o de) (V) 0 (N) 0 (V) a (J) (F) 0 (X) 0 (F) 0 (S) 0 (R) 0 (R) 0 (P) 0 (L) SE Internal SPEIFITIONS F Flare EF ODF Solder Internal FV-/ FVE-/ EFV-/ EFVE-/ / FV-/ FVE-/ EFV-/ EFVE-/ / FV-/ FVE-/ EFV-/ EFVE-/ / FV- FVE- EFV- EFVE- FV--/ FVE--/ EFV--/ EFVE--/ -/ F VE- EFVE- FJ-/ FJE-/ EFJ-/ EFJE-/ / FJ-/ FJE-/ EFJ-/ EFJE-/ / FJ-/ FJE-/ EFJ-/ EFJE-/ / FJ-/ FJE-/ EFJ-/ EFJE-/ / F V--/ E FV--/ -/ F VE- EFVE- FJ- FJE- EFJ- EFJE- FS-/ FSE-/ EFS-/ EFSE-/ / FS-/ FSE-/ EFS-/ EFSE-/ / FS-/ FSE-/ EFS-/ EFSE-/ / FS-/ FSE-/ EFS-/ EFSE-/ / FJ--/ FJE--/ EFJ--/ EFJE--/ -/ F JE- EFJE- FS- FSE- EFS- EFSE- FP-/ FPE-/ EFP-/ EFPE-/ / FP-/ FPE-/ EFP-/ EFPE-/ / FP-/ FPE-/ EFP-/ EFPE-/ / FP-/ FPE-/ EFP-/ EFPE-/ / FS--/ FSE--/ EFS--/ EFSE--/ -/ F SE- EFSE- FP- FPE- EFP- EFPE- FP--/ FPE--/ EFP--/ EFPE--/ -/ F PE- EFPE- ELEMENT SIZE NO., KNIFE EDGE JOINT NOMINL PITY Tons of Refrigeration Z ZP0 Z ZP Z ZP 0 ONNETIONS Inches SE Flare / E ODF Solder lue figures are standard and will be furnished unless otherwise specified. INLET OUTLET / / Q / / / e / / / Q / / / e / / / Q / / / e / / / Q / / / e / -/ Q The / SE inlet fitting has a long taper on the flare surface. / x / reducing flare nut will allow / OD tubing to be attached to this fitting. E ODF Solder on Type EF valves indicates a female connection on the valve of proper diameter to receive copper tubing of cresponding OD size. Thus / ODF will receive / OD tubing. e Nominal ton and larger F valves f R-a, R-0 and R-0 type refrigerants, and nominal -/ ton and larger f R- refrigerant require / SE Flare / ODF inlet, minimum. harges vailable Standard Tubing Length-Inches Net Shipping

15 SE Flare ULLETIN 0-0 / Page. / SE Inlet P/N &. / SE Fitting TOP VIEW 0.0 / SE Inlet P/N UL SIZES Inches STNDRD HRGES a OD x.00 Z & ZP Series 0.0 OD x OD x.00 DIMENSIONS Inches SE FITTING SIZE / Elbow.0. / Elbow.. / SE. / SE.0 ODF Solder. D D.. / ODF Insert P/N -00 / ODF Insert P/N / ODF onnection TOP VIEW 0. UL SIZES Inches STNDRD HRGES a OD x.00 Z & ZP Series 0.0 OD x OD x.00 DIMENSIONS Inches ODF FITTING SIZE D / ODF.. / ODF... / ODF..

16 Page / ULLETIN 0-0 ( Splan o de) (V) 0 (N) 0 (V) a (J) (F) 0 (X) 0 (F) 0 (S) 0 (R) 0 (R) 0 (P) 0 (L) SE Internal Y f Refrigerants -a-0-0 SE Flare & Extended ODF Solder onnections The brass body type Q, EQ, and SQ are replaceable cartridge style valves, whereby a cartridge can be selected to match the system capacity and installed in the valve body. ll share identical internal construction with external adjustments. The identification of the three valve body styles available is now unique. The Q body is supplied with the traditional SE flare connections. The EQ body is supplied with extended ODF solder connections and the series strainer. The SQ body features ODF solder connections with the fged inlet and replaceable strainer. These valves are all designed f small refrigeration systems, such as refrigerated cases, coolers, and freezers. The externally equalized version of these valves may be used on air conditioning and heat pump systems, the EQ body is specifically targeted f this application. This is the first cartridge type valve to be designed and marketed by Splan Valve ompany, and it can be supplied as a complete valve as three component parts: the thermostatic element, the valve body, and the replaceable cartridge ifice. The thermostatic element to valve body joint is the Splan traditional knife edge, metal-to-metal, joint which insures leak-proof construction. SELETIVE THERMOSTTI HRGES Since the valve body and thermostatic elements can be supplied as independent components, the installer can select the best possible thermostatic charge f the application. Splan selective thermostatic charges are specifically designed f low temperature, medium temperature and air conditioning applications. The element is manufactured with a large flat diaphragm to yield maximum power f best control perfmance. SPEIFITIONS Flare r ODY -RTRIDGE Internal Y Extended ODF Solder r ELEMENT SIZE NO., KNIFE EDGE JOINT Internal Y r Q-0 QE-0 EQ-0 EQE-0 SQ-0 SQE-0 0 / Q- QE- EQ- EQE- SQ- SQE- / Q- QE- EQ- EQE- SQ- SQE- Q- QE- EQ- EQE- SQ- SQE- -/ Q- QE- EQ- EQE- SQ- SQE- -/ Q- QE- EQ- EQE- SQ- SQE- -/ Q- QE- EQ- EQE- SQ- SQE- Q-0 QE-0 EQ-0 EQE-0 SQ-0 SQE-0 0 / Q- QE- EQ- EQE- SQ- SQE- / Q- QE- EQ- EQE- SQ- SQE- / Q- QE- EQ- EQE- SQ- SQE- Q- QE- EQ- EQE- SQ- SQE- -/ Q- QE- EQ- EQE- SQ- SQE- Q- QE- EQ- EQE- SQ- SQE- -/ Q-0 QE-0 EQ-0 EQE-0 SQ-0 SQE-0 0 / Q- QE- EQ- EQE- SQ- SQE- / Q- QE- EQ- EQE- SQ- SQE- / Q- QE- EQ- EQE- SQ- SQE- Q- QE- EQ- EQE- SQ- SQE- -/ Q- QE- EQ- EQE- SQ- SQE- Q- QE- EQ- EQE- SQ- SQE- Q-0 QE-0 EQ-0 EQE-0 SQ-0 SQE-0 0 / Q- QE- EQ- EQE- SQ- SQE- / Q- QE- EQ- EQE- SQ- SQE- / Q- QE- EQ- EQE- SQ- SQE- Q- QE- EQ- EQE- SQ- SQE- -/ Q- QE- EQ- EQE- SQ- SQE- Q- QE- EQ- EQE- SQ- SQE- Y Valves listed in this column NOT VILLE with MOP Type air conditioning charges. r Standard / SE (Q ody), / ODF (SQ and EQ ody). INTERNL PORT DESIGN The flow of refrigerant through the valve pt opposes the pin movement in all type Q, EQ and SQ valves. This design concept improves valve control stability when light loads occur and the pin modulates to a position close to the pt. This design also reduces eliminates the risk of charge migration in the thermostatic element which is inherent with other cartridge style valves. y design, the Splan thermostatic element is warmed by the entering liquid which flows through the top of the valve body. RTRIDGE NOMINL PITY-Tons f complete details of construction, see page harges vailable Standard Tubing Length-Feet Refer to Recommended Elements on Page U.S. Patent No.,, ONNETIONS Inches OLD figures are standard and will be funished unless otherwise specified Inlet x Outlet Q & QE Only / x / SE 0 ngle Inlet / x / SE 0 ngle Inlet / x / SE 0 ngle Inlet EQ Only / x / ODF Straight Thru EQE Only / x / ODF Straight Thru / x / ODF Straight Thru / x / ODF Straight Thru / x / ODF Straight Thru SQ & SQE Only / x / ODF 0 ngle Inlet - U.S. Patent No.,,0 Net Shipping -/

17 ULLETIN 0-0 / Page QE. QE DIMENSIONS Inches FITTING SIZE / SE, 0 ngle.. / SE, 0 ngle. 0. / SE. / SE.0. TOP VIEW. / SE Removable P/N / SE Inlet P/N EQE DIMENSIONS Inches FITTING SIZE /.0 /.. /. /. EQE. TOP VIEW 0... / ODF Insert P/N -00 / ODF Insert P/N SQE. Removable P/N -000 TOP VIEW QE, EQE, SQE UL SIZES Inches STNDRD HRGES a OD x.00 Z & ZP Series 0.0 OD x OD x.00 P Series 0.0 OD x.00 VG 0. OD x.00

18 Page / ULLETIN 0-0 ORDERING INSTRUTIONS QE 0 (/T) V / x / x / SE artridge Size Nominal apacity (tons) Valve Type Q, EQ, SQ = Internally Equalized QE, EQE, SQE = ly Equalized apillary Tube Length harge Refrigerant ode (See page ) onnection Size and Style: in x out x ext. eq. SELETING ODY Q EQ SQ SE (Internally Equalized) ODF (Internally Equalized) ODF (Internally Equalized) QE EQE SQE Replaceable U.S. Patent No.,,0 P/N -000 SE (ly Equalized) ODF (ly Equalized) U.S. Patent No.,, ODF (ly Equalized) KT--V SELETING THE ELEMENT V Element Label PPLITION IR ONDITIONING OMMERIL REFRIGERTION 0 F to 0 F LOW TEMPERTURE REFRIGERTION 0 F to 0 F apillary Tube Length (Standard = ft.) ulb Date ode Label (by week and year of manufacture) KT - - V bbreviation f "Kit" Element Size Number *Refrigerant ode See Page harge * While many new refrigerants and refrigerant blends have a unique letter code, many use the same thermostatic element as the traditional refrigerant they replace. Refer to the table below to select the crect thermostatic element. REOMMENDED THERMOSTTI ELEMENTS THERMOSTTI SYSTEM ELEMENT MOP a psig X X X X KT--FP0 0 X X X 0 X X X K T--VG X X X 0 X X X X X X X X X X X X X K T--FZ X KT--FZP X X K T--VZ X X 0 X X X X X X X X X X The Splan type ZP thermostatic charges have essentially the same characteristics as the conventional Z cross charges with one exception: they produce a pressure limit MOP. The ZP charges are not intended as replacements f the Z charges - they should only be used where a definite pressure limit is required to prevent mot overloading.

19 ULLETIN 0-0 / Page SELETING THE RTRIDGE Top surface is col coded to identify cartridge number apacity code on cartridge Identification tag with cartridge number (bends around capillary tubing) INDIVIDUL REPLEMENT PRTS PRT NUMER SIZE OLOR ODE RTRIDGE ND I.D. TG Q-0 Q- Q- Q- Q- Q- Q- 0 RED YELLOW GREEN LUE PINK LK WHITE MISELLNEOUS PRTS O - Oil ottle (With Oil) W- mm llen Wrench SK- artridge Service Kit (Empty) 000 artridge Service Kit (omplete as noted below) No. 0 - Red Qty. No. - lack Qty. artridge Service Kit Part No. - Yellow Qty. mm llen Wrench No. - Green Qty. No No. - lue Qty. Oil ottle No. - Pink Qty. No. - White Qty. R- R- NOMINL PITY ( tons) of SPORLN VLVE to be REPLED R-a R-0 R-0 R-0 R-0 R-0 Q VLVE RTRIDGE SIZE OLOR ODE / / / / / / / / / / / / / / / / 0 RED / / / / / / / / / YELLOW / / / / / / / GREEN -/ LUE -/ -/ -/ -/ -/ -/ -/ -/ PINK LK -/ -/ -/ WHITE OMPONENT SSEMLY Element mm llen Wrench (W-) Q ttach cartridge identification tag to element capillary tube. W (Oil) Lubricate O-ring. E Turn clockwise until seated (do not over tighten). Element Q Valve Tool (QVT-) Y fter hand tight, turn element clockwise 0 ( movement equal to one hex flat). View of Element R (Oil) Lubricate lock ring surface and top of push rods. T Hand tighten element. efe fter

20 Page 0 / ULLETIN 0-0 ( Splan o de) (V) 0 (N) 0 (V) a (J) (F) 0 (X) 0 (F) 0 (S) 0 (R) 0 (R) 0 (P) 0 (L) Internal Y Splan Type G valve is a fged brass body, externally adjustable valve with SE flare connections. The thermostatic element is replaceable, and the inlet connection has a removable 00 mesh strainer. This valve is designed f small refrigeration systems such as refrigerated cases, coolers and freezers. In addition to refrigeration applications, the externally equalized Type G valve may be used f small capacity air conditioning and heat pump units. Refrigerant distributs that will mate directly to this valve are listed below. Refer to Splan ulletin 0-0 f additional application infmation on this subject. Outlet onnections / SE SPEIFITIONS /" SE Flare GV-/ GVE-/ / GV-/ GVE-/ / GV-/ GVE-/ / GV-/ GVE-/ / GV- GVE- GV--/ GVE--/ -/ GVE- G V--/ -/ GVE- GJ-/ GJE-/ / GJ-/ GJE-/ / GJ-/ GJE-/ / GJ-/ GJE-/ / GJ- GJE- GJ--/ GJE--/ -/ GJE- GS-/ GSE-/ / GS-/ GSE-/ / GS-/ GSE-/ / GS-/ GSE-/ / GS- GSE- GS--/ GSE--/ -/ GSE- GP-/ GPE-/ / GP-/ GPE-/ / GP-/ GPE-/ / GP-/ GPE-/ / GP- GPE- GP--/ GPE--/ -/ GPE- Q The / SE inlet fitting has a long taper on the flare surface. / x / reducing flare nut will allow / OD tubing to be attached to this fitting. Y Valves listed in this column NOT VILLE with MOP Type air conditioning charges. / SE onnection TOP VIEW f Refrigerants -a-0-0 SE Flare onnections.. NOMINL PITY Tons of Refrigeration Distributs 0, 0, 0, 0, 0(R) ELEMENT SIZE NO., KNIFE EDGE JOINT harges vailable Refer to Recommended harges on Page DIMENSIONS Inches Standard Tubing Length-Feet ONNETIONS Inches SE Flare lue figures are standard and will be furnished unless otherwise specified. Removable P/N -000 INLET / / Q / / Q / Q / / Q / / Q / Q / / Q / / Q / Q / / Q / / Q / Q. f complete details of construction, see page OUTLET Net Shipping /. with external equalizer.. UL SIZES Inches STNDRD HRGES a OD x.0 Z & ZP Series 0.0 OD x OD x.0 X 0. OD x OD x.00 P Series 0.0 OD x.0 VG 0. OD x.00. / SE Inlet P/N Diameter of Type X harge Diaphragm ase is...0

21 f Refrigerants -a-0-0 SE Flare & ODF Solder onnections Splan Type EG valve is a fged brass body, externally adjustable valve with ODF solder connections. The thermostatic element is replaceable, and the inlet connection has a removable 00 mesh strainer which can be cleaned and/ replaced without removing the valve from the line. This valve is designed f small refrigeration systems such as refrigerated cases, coolers and freezers. In addition to refrigeration applications, the externally equalized Type EG valve may be used f small capacity air conditioning and heat pump units. Refrigerant distributs that will mate directly to this valve are listed below. Refer to Splan ulletin 0-0 f additional application infmation on this subject. f complete details of construction, see page ( Splan o de) Internal Y SPEIFITIONS UL SIZES Inches STNDRD HRGES a OD x.0 Z & ZP Series 0.0 OD x OD x.0 X 0. OD x OD x.00 P Series 0.0 OD x.0 VG 0. OD x.00 Outlet onnections / ODF ELEMENT SIZE NO., KNIFE EDGE JOINT T YPE ONNETIONS Inches E ODF Solder lue figures are standard and will be /" ODF furnished unless otherwise specified. Solder INLET OUTLET NOMINL PITY Tons of Refrigeration harges vailable Refer to Recommended harges on Page Distributs, Standard Tubing Length-Feet * Type EG valves manufactured pri to June use a smaller inlet strainer, P/N -000, which has a / brass hex head. urrent Type EG valves use inlet strainer P/N -000 which has a / brass hex head. These strainers are not interchangeable, but both are available as replacement parts. ULLETIN 0-0 / Page Replaceable U.S. Patent No.,,0 EGV-/ EGVE-/ / EGV-/ EGVE-/ / (V) EGV-/ EGVE-/ / EGV-/ EGVE-/ / 0 (N) EGV- EGVE- 0 (V) EGV--/ EGVE--/ -/ EGVE- E GV--/ -/ EGVE- EGJ-/ EGJE-/ / EGJ-/ EGJE-/ / a (J) EGJ-/ EGJE-/ / (F) EGJ-/ EGJE-/ / 0 (X) EGJ- EGJE- 0 (F) EGJ--/ EGJE--/ -/ EGJE- / / EGS-/ EGSE-/ / 0 (S) EGS-/ EGSE-/ / EGS-/ EGSE-/ / 0 (R) EGS-/ EGSE-/ / 0 (R) EGS- EGSE- EGS--/ EGSE--/ -/ EGSE- EGP-/ EGPE-/ / EGP-/ EGPE-/ / EGP-/ EGPE-/ / 0 (P) EGP-/ EGPE-/ / 0 (L) EGP- EGPE- EGP--/ EGPE--/ -/ EGPE- E ODF Solder indicates a female connection on the valve of proper diameter to receive copper tubing of cresponding OD size. Thus / ODF will receive / OD tubing. Y Valves listed in this column NOT VILLE with MOP Type air conditioning charges.. DIMENSIONS Inches * Removable P/N / ODF onnection. TOP VIEW.0. Diameter of Type X harge Diaphragm ase is..0 Net.0 Shipping

22 Page / ULLETIN 0-0 ( Splan o de) (V) 0 (N) 0 (V) a (J) (F) 0 (X) 0 (F) 0 (S) 0 (R) 0 (R) 0 (P) 0 (L) Internal Y f Refrigerants -a-0-0 SE Flare onnections Splan Type valve is a fged brass body, externally adjustable valve with SE flare connections. The thermostatic element is replaceable, and the inlet connection has a removable 0 mesh strainer. This valve is designed f refrigerated cases, coolers and freezers. In addition to refrigeration applications, the externally equalized Type valve may be used f small capacity air conditioning and heat pump units. Refrigerant distributs that will mate directly to this valve are listed below. Refer to Splan ulletin 0-0 f additional application infmation on this subject. SPEIFITIONS /" SE Flare Only V- ELEMENT SIZE NO., KNIFE EDGE JOINT ONNETIONS Inches SE Flare lue figures are standard and will be furnished unless otherwise specified. INLET Q The / SE inlet fitting has a long taper on the flare surface. / x / reducing flare nut will allow / OD tubing to be attached to this fitting. Y Valves listed in this column NOT VILLE with MOP Type air conditioning charges. OUTLET / Q / / / V- VE- V- VE- VE- / / J- J--/ JE--/ -/ J- JE- Outlet onnections / SE / SE NOMINL PITY Tons of Refrigeration / Q / / / / / S- / Q / / / JE- S- SE- S- SE- SE- / / P- harges vailable Refer to Recommended harges on Page Distributs 0, 0, 0, 0, 0(R) 0,, (R), (R), (R) Standard Tubing Length-Feet / Q / / / P- PE- P- PE- PE- / / f complete details of construction, see page Net Shipping TOP VIEW. / SE onnection. / SE Removable P/N / SE Removable P/N DIMENSIONS Inches onnections - SE Flare FITTING SIZE /. /. UL SIZES Inches STNDRD HRGES a OD x.0 Z & ZP Series 0.0 OD x OD x.0 X 0. OD x OD x.00 P Series 0.0 OD x.0 VG 0. OD x.00. Diameter of Type X harge Diaphragm ase is..0.

23 ( Splan o de) f Refrigerants -a-0-0 SE Flare onnections f complete details of construction, see page Internal Splan Type F valve is a small brass bar body valve with SE flare connections and balanced pt construction. This valve has the same exteri dimensions as the Type F valve. The thermostatic element is replaceable, and the inlet connection has a removable 00 mesh strainer. The balanced pt construction makes this valve ideally suited f small capacity refrigeration applications which operate over widely varying operating conditions. Refrigerant distributs that will mate directly to this valve are listed below. Refer to Splan ulletin 0-0 f additional application infmation on this subject. SPEIFITIONS SE Flare Outlet onnections / SE Pt Size NOMINL PITY Tons of Refrigeration Distributs 0, 0, 0, 0, 0(R) ELEMENT SIZE NO., KNIFE EDGE JOINT harges vailable Standard Tubing Length-Inches ONNETIONS Inches lue figures are standard and will be furnished unless otherwise specified. INLET SE Flare FV- FVE- / / / / Elbow Q (V) FV- FVE- / / 0 (N) FV- FVE- / -/ Z / / Elbow Q 0 (V) FV- FVE- -/ ZP0 / Elbow FV- FVE- -/ -/ FJ- FJE- / / a (J) / / Elbow Q FJ- FJE- / / (F) FJ- FJE- / / / Elbow Q 0 (X) FJ- FJE- -/ -/ 0 (F) / Elbow FJ- FJE- 0 FS- FSE- / / / / Elbow Q 0 (S) FS- FSE- / / 0 (R) FS- FSE- / Z / / Elbow Q 0 (R) FS- FSE- -/ ZP / Elbow FS- FSE- -/ FP- FPE- / / / / Elbow Q FP- FPE- / / 0 (P) FP- FPE- / Z / / Elbow Q 0 (L) FP- FPE- -/ ZP / Elbow FP- FPE- -/ Q The / SE inlet fitting has a long taper on the flare surface. / x / reducing flare nut will allow / OD tubing to be attached to this fitting. ULLETIN 0-0 / Page OUTLET / / Net Shipping / -/ DIMENSIONS Inches onnections - SE Flare FITTINGS SIZE / Elbow.. / Elbow.. / SE. / SE.0 / SE onnection TOP VIEW 0.. / SE Removable P/N UL SIZES Inches STNDRD HRGES a OD x.00 Z & ZP Series 0.0 OD x OD x.00 / SE Removable P/N

24 Page / ULLETIN 0-0 f Refrigerants -a-0-0 Extended Solder onnections & Splan Types SF & EF are small brass bar body valves with Extended ODF solder connections and the same balanced pt construction as the Type F valve. oth valves have replaceable thermostatic elements. The Type EF has a 00 mesh insert strainer. The Type SF has a 00 mesh removable strainer that can be cleaned and/ replaced while the valve is still soldered to the system tubing. The balanced pt construction makes these valves ideally suited f small capacity refrigeration applications which operate over widely varying conditions. Refrigerant distributs that will mate directly to these valves are listed below. Refer to Splan ulletin 0-0 f additional application infmation on this subject. SF Replaceable U.S. Patent No.,,0 Outlet onnections / ODF / ODF Distributs, 0,, (R) EF f complete details of construction, see page ( Splan o de) (V) 0 (N) 0 (V) a (J) (F) 0 (X) 0 (F) 0 (S) 0 (R) 0 (R) 0 (P) 0 (L) SPEIFITIONS SF Extended ODF Solder (with replaceable strainer) Internal SFV- SFV- SFV- SFV- SFV- SFJ- SFJ- SFJ- SFJ- SFJ- SFS- SFS- SFS- SFS- SFS- SFP- SFP- SFP- SFP- SFP- SFVE- SFVE- SFVE- SFVE- SFVE- SFJE- SFJE- SFJE- SFJE- SFJE- SFSE- SFSE- SFSE- SFSE- SFSE- SFPE- SFPE- SFPE- SFPE- SFPE- EF Extended ODF Solder Internal EFV- EFV- EFV- EFV- EFV- EFJ- EFJ- EFJ- EFJ- EFJ- EFS- EFS- EFS- EFS- EFS- EFP- EFP- EFP- EFP- EFP- EFVE- EFVE- ELEMENT SIZE NO., KNIFE EDGE JOINT Pt Size / / / / EFVE- / -/ EFVE- -/ EFVE- -/ -/ EFJE- EFJE- / / / / EFJE- / EFJE- -/ -/ EFJE- EFSE- EFSE- / / / / EFSE- / EFSE- -/ EFSE- -/ EFPE- EFPE- NOMINL PITY RNGE Tons of Refrigeration / / / / EFPE- / EFPE- -/ EFPE- -/ harges vailable Z ZP0 Z ZP Z ZP Standard Tubing Length-Inches ONNETIONS Inches lue figures are standard and will be furnished unless otherwise specified. INLET 0 / Extended ODF Solder OUTLET / / / Pointed Toward ottom ap Parallel to Outlet onnection Net Shipping -/

25 ULLETIN 0-0 / Page SF Replaceable P/N DIMENSIONS Inches & TOP VIEW / ODF onnection..0 UL SIZES Inches STNDRD HRGES a OD x.00 Z & ZP Series 0.0 OD x OD x.00 EF DIMENSIONS Inches. TOP VIEW / ODF Insert P/N UL SIZES Inches STNDRD HRGES a OD x.00 Z & ZP Series 0.0 OD x OD x.00

26 Page / ULLETIN 0-0 f Refrigerants -a-0-0 ODF Solder onnections Splan Type S valve is a brass bar body, externally adjustable valve with ODF solder connections. The thermostatic element is replaceable, and the inlet connection has a permanent mesh strainer. This valve is designed f both air conditioning and refrigeration applications. Refrigerant distributs that will mate directly to this valve are listed below. Refer to Splan ulletin 0-0 f additional application infmation on this subject. ( Splan o de) (V) 0 (N) 0 (V) a (J) (F) 0 (X) 0 (F) 0 (S) 0 (R) 0 (R) 0 (P) 0 (L) Internal Y SPEIFITIONS U Outlet onnections / ODF / ODF -/ ODF NOMINL PITY Tons of Refrigeration SV- SVE- SV- SVE- SV- SVE- SV- SVE- SVE- SVE-0 0 ELEMENT SIZE NO., KNIFE EDGE JOINT ONNETIONS Inches I ODF Solder lue figures are standard and will be furnished unless otherwise specified. INLET OUTLET / / /, / -/ / /, / -/ / / -/ SJ- SJE- / / /, / -/ SJ--/ SJE--/ -/ / /, / -/ SJ- SJE- SJE- / / -/ SJE- SS- SSE- / / /, / -/ SS- SSE- / /, / -/ SS- SSE- SSE- SSE- / / -/ SP- SPE- / / /, / -/ SP- SPE- SP- SPE- / /, / -/ SPE- SPE- / / -/ Y Valves listed in this column NOT VILLE with MOP Type air conditioning charges. U Standard onnection / ODF Solder, / SE flare connection available on request. I ODF Solder indicates a female connection on the valve of proper diameter to receive copper tubing of cresponding OD size. Thus / ODF will receive / OD tubing. TOP VIEW 0 harges vailable Refer to Recommended harges on Page Distributs 0,, (R),, (R),, (R) Standard Tubing Length-Feet. f complete details of construction, see page Net Shipping DIMENSIONS Inches FITTING SIZE /. /.. /.0. /. -/..0 ODF Solder / ODF onnection.. UL SIZES Inches STNDRD HRGES a OD x.0 Z & ZP Series 0.0 OD x OD x.0 X 0. OD x OD x.00 P Series 0.0 OD x.0 VG 0. OD x.00. Diameter of Type X harge Diaphragm ase is.

27 f complete details of construction, see page f Refrigerants -a-0-0 Extended ODF Solder onnections Splan Type ES valve is a brass bar body valve having the same physical size as the Type S valve except the Type ES features a balanced pt construction and extended ODF connections. The thermostatic element is replaceable. The balanced pt construction makes this valve ideally suited f refrigeration and air conditioning applications which operate over widely varying conditions. Refrigerant distributs that will mate directly to this valve are listed below. Refer to Splan ulletin 0-0 f additional application infmation on this subject. Outlet onnections / ODF -/ ODF -/ ODF Distributs,, (R),, (R),,, (R) ULLETIN 0-0 / Page ( Splan o de) SPEIFITIONS NOMINL PITY Tons of Refrigeration harges vailable ELEMENT SIZE NO., KNIFE EDGE JOINT Standard Tubing Length-Feet ONNETIONS Inches lue figures are standard and will be furnished unless otherwise specified. INLET I Extended ODF Solder OUTLET Net Shipping (V) 0 (N) 0 (V) ESVE- / / / -/ ESVE- /, / / /, -/ -/ a (J) (F) 0 (X) 0 (F) 0 (S) 0 (R) 0 (R) E SJE- / o r / / -/ * Refer to Recommended harges on Page ESJE- /, / / /, -/ -/ E SSE- / o r / / -/ ESSE--/ -/ /, / / /, -/ -/ / Pointed Toward ottom ap Parallel to onnection 0 (P) 0 (L) E SPE- / o r / / -/ ESPE--/ -/ /, / / /, -/ -/ ODF Solder indicates a female connection on the valve of proper diameter to receive copper tubing of cresponding OD size. Thus / ODF will receive / OD tubing. * X - harge Not vailable DIMENSIONS Inches FITTING SIZE /.. /..0 /... -/.. -/.0. TOP VIEW 0 / ODF onnection.. UL SIZES Inches STNDRD HRGES a OD x.0 Z & ZP Series 0.0 OD x OD x.0 P Series 0.0 OD x.0 VG 0. OD x.00..

28 Page / ULLETIN 0-0 f Refrigerants -a-0-0 ODF Solder onnections U.S. Patent Number,, Splan Type O valve is a brass bar body, externally adjustable valve with ODF solder connections. The thermostatic element is replaceable, and the inlet connection has a permanent mesh strainer. This valve type features a balanced pt construction, and it is designed f both air conditioning and refrigeration applications. synthetic seating surface provides tight shut-off during system off periods. This valve type has two body styles: a small body which provides capacities up to 0 tons R-, and a large body which extends capacities to 0 tons R-. Refrigerant distributs that will mate directly to this valve are listed below. Refer to Splan ulletin 0-0 f additional application infmation on this subject. Outlet onnections -/ ODF -/ ODF -/ ODF Distributs,, (R),,, (R),,, (R) f complete details of construction, see page ( Splan o de) (V) 0 (N) 0 (V) a (J) (F) 0 (X) 0 (F) 0 (S) 0 (R) 0 (R) 0 (P) 0 (L) U Standard onnection / ODF Solder, / SE flare connection available on request. I ODF Solder indicates a female connection on the valve of proper diameter to receive copper tubing of cresponding OD size. Thus / ODF will receive / OD tubing. * X - harge Not vailable SPEIFITIONS U NOMINL PITY Tons of Refrigeration OVE- OVE-0 0 OVE-0 0 OVE-0 0 OVE- OVE-0 0 OJE- OJE- OJE- OJE- OJE- OJE-0 0 OSE- OSE- OSE- OSE-0 0 OSE- OSE- OPE- OPE- OPE- OPE-0 0 OPE- OPE- Element Size No. ELEMENT SIZE NO.'s and, KNIFE EDGE JOINT ONNETIONS Inches I ODF Solder lue figures are standard and will be furnished unless otherwise specified. INLET / OUTLET -/ -/ -/ -/ -/ / -/ -/ -/ -/ -/ / -/ -/ -/ -/ -/ harges vailable * Refer to Recommended harges on Page Standard Tubing Length-Feet / -/ -/ -/ -/ -/ Net Shipping

29 ULLETIN 0-0 / Page O WITH NUMER ELEMENT..0.. DIMENSIONS Inches STRIGHT THRU ODF SOLDER / / /. 0. / ODF onnection TOP VIEW.0 / ODF. (Optional / SE) UL SIZES Inches STNDRD HRGES a OD x.0 Z & ZP Series 0.0 OD x OD x.0 P Series 0.0 OD x.0 VG 0. OD x.00 O WITH NUMER ELEMENT. / ODF onnection TOP VIEW. / ODF. (Optional / SE)..0. DIMENSIONS Inches STRIGHT THRU ODF SOLDER -/. 0. -/. 0. -/..0 UL SIZES Inches STNDRD HRGES a OD x OD x OD x.00 Z & ZP Series 0. OD x OD x.00 P Series 0. OD x.00 VG 0. OD x.00

30 Page 0 / ULLETIN 0-0 f Refrigerants -a-0-0 ODF Solder-Flange onnections Splan Type H valve is a brass bar body, externally adjustable valve available with either ODF solder FPT flange connections. The thermostatic element is replaceable, and the inlet connection has a permanent mesh strainer. The FPT flange connection requires the Splan K- adapter kit. This valve type provides the smallest capacity TEVs with flange connections, and it is designed f both air conditioning and refrigeration applications. Refrigerant distributs that will mate directly to this valve are listed below. Refer to Splan ulletin 0-0 f additional application infmation on this subject. Outlet onnections / ODF / ODF -/ ODF H flange type Distributs 0,, (R),, (R),, (R) 0, 0,, (aluminum) f complete details of construction, see page ( Splan o de) (V) 0 (N) 0 (V) a (J) (F) 0 (X) 0 (F) 0 (S) 0 (R) 0 (R) Internal Y SPEIFITIONS U NOMINL PITY Tons of Refrigeration harges vailable ELEMENT SIZE NO., KNIFE EDGE JOINT HV--/ HVE--/ -/ o HV--/ HVE--/ -/ HVE- / / / -/ HVE- HVE- HVE-0 0 / / -/ HJ--/ HJE--/ -/ / / / / HJ- HJE- HJ- HJE- HJ- HJE- / / / -/ HJE- HJE- / / -/ HS--/ HSE--/ -/ / / / / HS- HSE- HS- HSE- HSE--/ -/ / / / -/ HSE- / -/ o / / / HSE- / HP--/ HPE--/ -/ / r HP- HPE- 0 (P) HP- HPE- / r 0 (L) HPE--/ -/ HPE- HPE- / Y Valves listed in this column NOT VILLE with MOPType air conditioning charges. U Standard onnection / SE Flare, / ODF Solder connection available on request. I ODF Solder indicates a female connection on the valve of proper diameter to receive copper tubing of cresponding OD size. Thus, / ODF will receive / OD tubing. O Kit K- with two brass bushings is available f two purposes: ) To allow the current Type H valve to replace obsolete Types T and H with. x 0. flange rings by mating with the smaller flange ring bushings and/ distributs. ) To allow the Type H to use / FPT connections Part number -00 and / socket weld connections Part number Order the appropriate / connections and one K- per valve. ONNETIONS Inches I ODF Solder Flange lue figures are standard and will be furnished unless otherwise specified. INLET / r / OUTLET / / Refer to Recommended harges on Page Standard Tubing Length-Feet o / / -/ / -/.0. Flange Ring Size OD x ID Inches O Net Shipping. x DIMENSIONS Inches SOLDER USHING /, /, / /.0 0. UL SIZES Inches STNDRD HRGES a OD x OD x OD x.00 Z & ZP Series 0. OD x OD x.00 X 0. OD x OD x.00 P Series 0. OD x.00 VG 0. OD x.00.0 Diameter of Type X harge Diaphragm ase is.

31 f Refrigerants -a-0-0 ODF Solder-Flange onnections f complete details of construction, see page ( Splan o de) (V) 0 (N) 0 (V) a (J) (F) 0 (X) 0 (F) 0 (S) 0 (R) 0 (R) 0 (P) 0 (L) U SPEIFITIONS ELEMENT SIZE NO., GSKET JOINT lue figures are standard and will be furnished unless otherwise specified. P ONNETIONS INHES { ODF Solder Flange INLET MVE- MVE- / -/ MVE- MVE- / -/ MJE- MJE-0 0 Splan Type M valve is a cast bronze body, externally adjustable valve with either ODF solder FPT flange connections. The thermostatic element is replaceable, and the inlet connection has a permanent mesh strainer. This valve type provides capacities greater than the Type H, and it is designed f both air conditioning and refrigeration applications. Flanges f the Type M valve are interchangeable with the Type V. Refrigerant distributs that will mate directly to this valve are listed below. Refer to Splan ulletin 0-0 f additional application infmation on this subject. NOMINL PITY Tons of Refrigeration Outlet onnections -/ ODF -/ ODF -/ ODF M/V flange harges vailable Refer to Recommended harges on Page Standard Tubing Length- Feet Distributs,, (R),,, (R),,, (R),, (aluminum) / -/ MJE- MSE- 0 / -/ MSE-0 0 / -/ MSE- MSE-0 0 / -/ MPE- MPE-0 0 / -/ MPE- MPE-0 0 / -/ OUTLET -/ -/ -/ ULLETIN 0-0 / Page Flange Ring Size OD x ID Inches. x. U Standard onnection / SE Flare. / ODF Solder connection available on request. P FPT connections also available on request; / FPT - Part Number 0-000, / FPT - Part Number 0-00, FPT - Part Number { ODF Solder indicates a female connection on the valve of proper diameter to receive copper tubing of cresponding OD size. Thus, / ODF will receive / OD tubing. Net Shipping. DIMENSIONS Inches SOLDER USHING /. 0. -/, -/. 0. -/... UL SIZES Inches STNDRD HRGES a OD x.00 Z & ZP Series 0. OD x OD x.00 X 0. OD x OD x.00 P Series 0. OD x.00 VG 0. OD x.00. Diameter of Type X harge Diaphragm ase is.

32 Page / ULLETIN 0-0 ( Splan o de) (V) 0 (N) 0 (V) a (J) (F) 0 (X) 0 (F) 0 (S) 0 (R) 0 (R) U f Refrigerants -a-0-0 ODF Solder-Flange onnections Splan Type V valve is a cast bronze body, externally adjustable valve available with either ODF solder FPT flange connections. The thermostatic element is replaceable, and the inlet connection has a permanent mesh strainer. This valve features a dual pt semibalanced design, and it is designed f both air conditioning and refrigeration applications. synthetic seating surface provides tight shut-off during system off periods. This valve provides greater capacities than the Type M. Flanges f the Type V valve are interchangeable with the Type M. Refrigerant distributs that will mate directly to this valve are listed below. Refer to Splan ulletin 0-0 f additional application infmation on this subject. VVE- VVE-0 0 SPEIFITIONS NOMINL PITY Tons of Refrigeration VVE VJE- VJE- VJE- VSE- VSE-0 0 VSE-0 0 Outlet onnections -/ ODF -/ ODF M/V flange harges vailable Refer to Recommended harges on Page Std. Tubing Lgth.-Ft. ELEMENT SIZE NO., GSKET JOINT 0 Distributs,,, (R),,, (R),, (aluminum) lue figures are standard and will be furnished unless otherwise specified. P ONNETIONS Inches { ODF Solder Flange INLET -/ -/ OUTLET -/ -/ -/ f complete details of construction, see page Flange Ring Size OD x ID Inches Net Shipping. x. 0 0 (P) 0 (L) VPE- VPE-0 0 VPE-0 0 Standard onnection / SE Flare. / ODF Solder connection available on request. 0 FPT connections also available on request; / FPT - Part Number 0-000, / FPT - Part Number 0-00, FPT - Part Number { ODF Solder indicates a female connection on the valve of proper diameter to receive copper tubing of cresponding OD size. Thus, / ODF will receive / OD tubing.. DIMENSIONS Inches SOLDER USHING /. 0. -/, -/. 0. -/... UL SIZES Inches STNDRD HRGES a OD x.00 Z & ZP Series 0. OD x OD x.00 X 0. OD x OD x.00 P Series 0. OD x.00 VG 0. OD x.00. Diameter of Type X harge Diaphragm ase is.

33 ( Splan o de) f Refrigerants -a ODF Solder-Flange onnections f complete details of construction, see page U Splan Type W valve is a cast bronze body, externally adjustable valve available with ODF solder flange connections. The thermostatic element is replaceable, and the inlet connection has a permanent mesh strainer. This valve features a dual pt semi-balanced design, and it is designed primarily f large capacity chillers. synthetic seating surface provides tight shut-off during system off periods. This valve provides the largest capacities available f flange connection TEVs. Refrigerant distributs that will mate directly to this valve are listed below. Refer to Splan ulletin 0-0 f additional application infmation on this subject. SPEIFITIONS NOMINL PITY Tons of Refrigeration Outlet onnections -/ ODF -/ ODF harges vailable ELEMENT SIZE NO.'s and, GSKET JOINT Element Size No. Distributs,,, (R),,, (R) lue figures are standard and will be furnished unless otherwise specified. Std. Tubing Lgth.-Ft. ONNETIONS Inches } ODF Solder Flange INLET OUTLET ULLETIN 0-0 / Page Flange Ring Size OD x ID Inches e Net Shipping (V) 0 (N) 0 (V) a (J) (F) 0 (X) 0 (F) WVE- q WVE-0 0 G only WJE-0 0 q WJE-0 0 G only 0 -/ -/ -/ -/ -/ -/ -/ -/. x. 0 U Standard onnection / SE Flare, / ODF Solder connection available on request. } ODF Solder indicates a female connection on the valve of proper diameter to receive copper tubing of cresponding OD size. Thus, -/ ODF will receive -/ OD tubing. q Refer to Recommended harges, Page. e F -/ NPT connections, der flanges separately f M solenoid eg P/N -. The customer must supply / diameter x long bolts and / diameter nuts.. *.0 D 0. E. 0. Diameter olt Holes D DIMENSIONS Inches ONNETIONS D E F -/ / / / UL SIZES Inches ELEMENT STNDRD S IZE NO. HRGES a 0. OD x.00 Z & ZP Series 0. OD x.00 X 0. OD x.00 P Series 0. OD x.00 VG 0. OD x.00 G 0. OD x.00. F F *Diameter of Diaphragm ase. f small W and. f large W

34 Page / ULLETIN 0-0 Refer to Splan atalog f complete infmation on Splan s line of products f ammonia refrigeration systems. f Refrigerant mmonia FPT Flange onnections Splan Type D valve is a gray cast iron body, externally adjustable valve available with either FPT socket weld flange connections. The thermostatic element is replaceable, and all internal parts are serviceable. n optional XD-0 (/ FPT) external inlet strainer may be dered with this valve. This valve type provides the smallest capacity TEVs f ammonia service. The nominal and ton Type D valves are identical with the exception of their discharge tubes. One of these valves can be converted to the other by exchanging the discharge tubes. The nominal 0 and ton Type D valves are also identical with the exception of their discharge tubes, and may be converted to each other by exchanging discharge tubes. Refrigerant distributs that will mate directly to this valve are listed below. Refer to Splan ulletin 0-0 f additional application infmation on this subject. Note: The discharge tubes must be removed when a refrigerant distribut is applied to the valves. Outlet onnections D flange Distributs 0,,, 0 (aluminum) (aluminum) f complete details of construction, see page Internal /" FPT NOMINL PITY Tons of Refrigeration SPEIFITIONS Pt Size Inches D- DE- / / D- DE- / / D- DE- / / D-0 DE-0 0 / / D- DE- / / q Refer to Page f pplication Recommendations. w Socket weld connections available upon request.. Discharge Tube Orifice Inches ELEMENT SIZE NO., GSKET JOINT q harges vailable -Z-L lue figures are standard and will be furnished unless otherwise specified. Std. Tubing Lgth.-Ft. 0 ONNETIONS Inches w FPT INLET OUTLET Flange Ring Size OD X ID Inches /, / /. x 0. UL SIZES Inches HRGES - mmonia - Z - L 0. x.00 Net Shipping.. ompact combination of XD M Solenoid Valve D Expansion Valve & 0 Steel Distribut.0 Inlet Screen ssembly / Pt P/N -000 / & / Pt P/N Types XD D Expansion Valve & Steel Distribut

35 Internal f Refrigerant mmonia FPT Flange onnections f complete details of construction, see page /" FPT NOMINL PITY Tons of Refrigeration Splan Type valve is a gray cast iron body, externally adjustable valve with either FPT socket weld flange connections. The thermostatic element is replaceable. n optional 00 (/ FPT) 00 (/ FPT) strainer may be dered with this valve. This valve provides the largest capacity TEVs f ammonia service. The nominal 0 and 0 ton Type valves are identical with the exception of their discharge tubes. One of these valves can be converted to the other by exchanging their discharge tubes. The nominal and 00 ton Type valves do not employ a discharge tube, n are their outlets tapped to receive one. Refrigerant distributs that will mate directly to this valve are listed below. Refer to Splan ulletin 0-0 f additional application infmation on this subject. Note that the discharge tube must be removed from the nominal 0, 0, and 0 ton Type valves when a refrigerant distribut is applied. Outlet onnections flange SPEIFITIONS Pt Size Inches Discharge Tube Orifice Inches -0 E-0 0 / / -0 E-0 0 / / -0 E-0 0 / / - E- / -00 E / w Socket weld connections available upon request. Distributs, (aluminum) ELEMENT SIZE NO., GSKET JOINT harges vailable L Only lue figures are standard and will be furnished unless otherwise specified. Std. Tubing Lgth.-Ft. 0 ONNETIONS Inches w FPT INLET /, / / OUTLET ULLETIN 0-0 / Page Refer to Splan atalog f complete infmation on Splan s line of products f ammonia refrigeration systems. Flange Ring Size OD x ID Inches Net Shipping. x. 0.. UL SIZES Inches HRGE - mmonia L - Only 0. OD x Inlet Screen ssembly P/N Expansion Valve & luminum Distribut

36 Page / ULLETIN 0-0 MTERILS & DETILS OF ONSTRUTION VLVE NI RI F EF Q SQ EQ G EG S F SF EF ES ODY Machined rass ar rass Fging Machined rass ar SET Monel rass Monel rass PIN Stainless Steel PIN RRIER rass PUSHROD(S) Triangular Stainless Steel Stainless Steel Internally Equalized: Triangular Stainless Steel ly Equalized: Round Stainless Steel OF JOINTS Knife Edge, Metal to Metal ONNETIONS SE Flare, Inlet Fitting Silver Soldered to ody SE Flare Fittings Silver Soldered to ody Extended opper Fittings Silver Soldered to ody SE Flare Fittings Silver Soldered to ody Extended opper Fittings Silver Soldered to ody SE Flare, Integral Part of rass Fged ody Extended opper Fittings Silver Soldered to ody SE Flare, Integral Part of rass Fged ody Wrought opper Fittings Silver Soldered to ody SE Flare Fittings Silver Soldered to ody Extended opper Fittings Silver Soldered to ody INLET STRINER Removable Screen No Removable Screen Insert Removable Screen Insert Removable Screen oarse Mesh Disc Removable Screen Insert MLL S O RGE L O H M rass Pt Machined In ody Stainless Steel rass ronze V asting Dual Pt, Seats Machined In Valve ody W D Gray Iron asting Stainless Steel Steel lloy Stainless Steel rass Piston With Synthetic Seating Surface Stainless Steel ronze Piston With Synthetic Seating Surface Tungsten arbide 0 & 0 Ton: Tungsten arbide 0,, & 00 Ton: Stainless Steel rass Stainless Steel Stainless Steel Knife Edge t Element and ottom ap Gasket t Seal ap Gasket Wrought opper Fittings Silver Soldered to ody Solder-Flange, Pipe Flange Pipe Flange, Socket Weld oarse Mesh Disc Removable Screen NOTE: Materials and onstruction specifications listed on this page may change without notice. ontact Splan Valve ompany f current specifications on materials and other details of construction.

37 OEM THERMOSTTI EXPNSION VLVES ULLETIN 0-0 / Page In addition to the standard line of Expansion Valves listed in this bulletin, special valve types are also available to fill manufacturers specific requirements. Listed below are examples of valves that are supplied f quantity ders. VLVE ONNETION VLVE DESRIPTION and PPLITION TYPIL REPLEMENT TEVs I/I SE Flare ODF Solder Small brass body valve available with either angle style straight through connections. Type I valves with straight through connections are nmally supplied nonadjustable. The Type I is a Type I valve modified to incpate balanced pt construction. The thermostatic element is not replaceable on valves manufactured pri to. urrent models use a replaceable No. element. Typical applications: small capacity R- air conditioning and heat pump systems. RI, G, EG,, S, Q, SQ, EQ Y-I SE Flare ODF Solder Type I valve modified to incpate an internal check valve and bypass tube to allow f reverse flow with heat pump applications. The valve is not adjustable. The thermostatic element is not replaceable on valves manufactured pri to. urrent models use a replaceable No. element. Typical applications: small capacity R- heat pump systems. RI, G, EG,, S, Q, SQ, EQ Note: check valve must be installed around the TEV to allow flow in the reverse direction. I SE Flare ODF Solder Small brass body valve available with either angle style straight through connections. Type I valves with straight through connections are nmally supplied nonadjustable. urrent models use a replaceable No. element. This valve is available with the Rapid Pressure alancer (RP) feature f off-cycle pressure equalization. Typical applications: small capacity R- air conditioning and heat pump systems. RI, G, EG,, S, Q, SQ, EQ I/I SE Flare ODF Solder Type I/I valves modified to incpate an internal check valve to allow f reverse flow with heat pump applications. Type I/I valves with straight through connections are nmally supplied non-adjustable. The valve uses a replaceable No. element. Typical applications: small capacity R- heat pump systems. RI, G, EG,, S, Q, SQ, EQ Note: check valve must be installed around the TEV to allow flow in the reverse direction. F SE Flare ODF Solder Small brass body valve available only with straight through connections and external adjustment. The thermostatic element is not replaceable on valves manufactured pri to. urrent models use a replaceable No. element. Typical applications: small capacity air conditioning and refrigeration applications where an external adjustment is desired. RI, G, EG,, S, Q, SQ, EQ X SE Flare ODF Solder rass body valve available with either angle style straight through connections. ngle style valve is available only with SE flare connections. Type X valves with straight through connections are nmally supplied nonadjustable. The thermostatic element is a replaceable type, size number. This valve is available with the Rapid Pressure alancer (RP) feature in certain nominal capacities f off-cycle pressure equalization. Typical applications: R- air conditioning and heat pump systems. RI, G, EG,, S, Q, SQ, EQ FETURES NOT INLUDED IN THIS ULLETIN Special features such as non-adjustable construction similar modifications are also available f both standard and special valves when dered in reasonable quantities. utomatic (constant pressure) expansion valves are also available on special der. If you have a special valve application, contact your Splan Sales Engineer Splan Valve ompany, 0 Lange Drive, Washington, Missouri 00, --.

38 Page / ULLETIN 0-0 P-H DIGRM LENDS ubble Point Refrigeration ycle Lines of onstant Temperature Dew Point To determine superheat, use Dew Point values. To determine subcooling, use ubble Point values. PRESSURE TEMPERTURE HRT Yellow Green lue Pink Sand Orange Temperature, F G reen Lt. rown Purple Yellow Purple Teal White PSIG * * * * (F) (V) a(j) MP 0(X) ULE POINT 0 HP0 0(L) ULE POINT R EFRIGERNT (Splan ode) HP 0(S) ULE POINT KLE (V) KLE 0(N) ULE POINT 0 0 ULE POINT FX-0 0(R) ULE POINT FX- 0(F) ULE POINT 0(R) 0(P) () *Inches mercury below one atmosphere

TYPE EMC. Thermostatic Expansion Valve

TYPE EMC. Thermostatic Expansion Valve TYPE EMC Thermostatic Expansion Valve with ODF Solder or SAE Flare Connections for Refrigerants,, 4a, 404A, 502 & 507 BULLETIN --4 June 1995 The Sporlan Type EMC thermostatic expansion valve (TEV) is a

More information

Thermostatic expansion valves TUA/TUAE

Thermostatic expansion valves TUA/TUAE MAKING MODERN LIVING POSSIBLE Technical brochure Thermostatic expansion valves A/AE www.danfoss.com Thermostatic expansion valves, type A/AE Contents Page Introduction... Features... Standard range...

More information

MAKING MODERN LIVING POSSIBLE. Thermostatic expansion valve Type TUB/TUBE and TUC/TUCE REFRIGERATION AND AIR CONDITIONING.

MAKING MODERN LIVING POSSIBLE. Thermostatic expansion valve Type TUB/TUBE and TUC/TUCE REFRIGERATION AND AIR CONDITIONING. MAKING MODERN LIVING POSSIBLE Thermostatic expansion valve Type B/BE and C/CE REFRIGERATION AND AIR CONDITIONING Technical leaflet Thermostatic expansion valve, type B/BE and C/CE Contents Page Introduction........................................................................................

More information

Thermostatic expansion valves TUB/TUBE and TUC/TUCE

Thermostatic expansion valves TUB/TUBE and TUC/TUCE MAKING MODERN LIVING POSSIBLE Technical brochure Thermostatic expansion valves B/BE and C/CE www.danfoss.com Thermostatic expansion valve, type B/BE and C/CE Contents Page Introduction........................................................................................

More information

CF (Conflat Flange) Fittings - Adapters. (505)

CF (Conflat Flange) Fittings - Adapters.  (505) F (onflat ) 1 Fittings - dapters www.idealvac.com (505)72-0037 1 Vacuum Fittings - dapters - olt Kits F - onflat F onflat flanges (F) are used for ultra- Vin elasmer gaskets can be used over and over but

More information

Solenoid valves Type EVR 2 g 40 NC/ NO New EVR 6 with Steel cover design

Solenoid valves Type EVR 2 g 40 NC/ NO New EVR 6 with Steel cover design MAKING MODERN LIVING POSSIBLE Technical brochure Solenoid valves EVR 2 g 40 NC/ NO New with Steel cover design EVR is a direct or servo operated solenoid valve for liquid, suction, and hot gas lines with

More information

Product Data CNPVP, CNPVT, CNPVU, CNRVU EVAPORATOR COIL N COIL - CASED AND UNCASED UPFLOW, DOWNFLOW

Product Data CNPVP, CNPVT, CNPVU, CNRVU EVAPORATOR COIL N COIL - CASED AND UNCASED UPFLOW, DOWNFLOW CNPVP, CNPVT, CNPVU, CNRVU EVPORTOR COIL N COIL - CSED ND UNCSED UPFLOW, DOWNFLOW Product Data CNPVP CNPVT (Transition) CN(P,R)VU 06008 06007 06004 This vertical design N -coil is a furnace coil designed

More information

Solenoid valve Types EVR 2 - EVR 40

Solenoid valve Types EVR 2 - EVR 40 Data sheet Solenoid valve s EVR 2 - EVR 40 EVR is a direct or servo operated solenoid valve for liquid, suction, and hot gas lines with HCFC and HFC refrigerants. EVR valves are supplied complete or as

More information

Product Data. CNPVP, CNRVP, CNPVT, CNRVT, CNPVU, CNRVU Evaporator Coil N Coil Cased and Uncased Upflow, Downflow

Product Data. CNPVP, CNRVP, CNPVT, CNRVT, CNPVU, CNRVU Evaporator Coil N Coil Cased and Uncased Upflow, Downflow CNPVP, CNRVP, CNPVT, CNRVT, CNPVU, CNRVU Evaporator Coil N Coil Cased and Uncased Upflow, Downflow Product Data CN(P,R)VP CN(P,R)VT (Transition) A06008 A06007 This vertical design N -coil is a furnace

More information

Accumulators Virginia KMP Suction Line Accumulators

Accumulators Virginia KMP Suction Line Accumulators Accumulators Virginia KMP Suction Line Accumulators The Virginia KMP suction line accumulator's purpose is to prevent excessive quantities of liquid refrigerant and oil from returning to the compressor.

More information

IBV Series C Carbon Steel Inverted Bucket Vertical Steam Trap

IBV Series C Carbon Steel Inverted Bucket Vertical Steam Trap Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

IBV Series Z Alloy Steel Inverted Bucket Vertical Steam Trap

IBV Series Z Alloy Steel Inverted Bucket Vertical Steam Trap Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

INSTALLATION INSTRUCTIONS ATV Plow Blade Part Number: (50 ), (54 ), or (60 ) Application: All Terrain Vehicles

INSTALLATION INSTRUCTIONS ATV Plow Blade Part Number: (50 ), (54 ), or (60 ) Application: All Terrain Vehicles INSTALLATION INSTRUCTIONS ATV Plow Blade Part Number: 78950 (50 ), 78954 (54 ), or 78960 (60 ) Application: All Terrain Vehicles Your safety, and the safety of others, is very important. To help you make

More information

Product Data. CNPHP, CNRHP Evaporator Coil N Coil --- Cased Horizontal CNPHP / CNRHP

Product Data. CNPHP, CNRHP Evaporator Coil N Coil --- Cased Horizontal CNPHP / CNRHP CNPHP, CNRHP Evaporator Coil N Coil --- Cased Horizontal Product Data 06005 This horizontal design N -coil is an evaporator coil designed to provide the highest standards of reliability and durability.

More information

Sight Glass and Moisture Indicator Virginia KMP Series LDE

Sight Glass and Moisture Indicator Virginia KMP Series LDE Sight Glass and Moisture Indicator Virginia KMP LDE DIMENSIONS: Dimension Dimension Connection Type "A" "B" Inches (mm) Inches (mm) LDE2 1/4 Male X 1/4 Male 2-7/8 72 1-7/ 36 LDE2S 1/4 Sweat X 1/4 Sweat

More information

Series 7500 Formed Metal Bellows Catalog 974C

Series 7500 Formed Metal Bellows Catalog 974C Series 00 Formed Metal Bellows Catalog C Innovators of the industry Bellows assemblies for safety valves, control valves, and regulators. When you look for a formed bellows which is reliable, has a long

More information

MOTORIZED 3-WAY VALVE APPLICATION INSTRUCTIONS FOR LOW TEMPERATURE PROTECTION KIT MODELS PB AND CF/CH

MOTORIZED 3-WAY VALVE APPLICATION INSTRUCTIONS FOR LOW TEMPERATURE PROTECTION KIT MODELS PB AND CF/CH MOTORIZED -WY VLVE PPLICTION INSTRUCTIONS FOR LOW TEMPERTURE PROTECTION KIT 10017190 MODELS PB 50-001 ND CF/CH 0-07 WRNING Electrical Shock Hazard-- For your safety, turn OFF electrical power supply before

More information

Nickel-Plated Brass Push-In Fittings - NPTF/INCH

Nickel-Plated Brass Push-In Fittings - NPTF/INCH /INCH Tube Connections: External /8, 5/32, /4, 5/6, 3/8, /2 Thread Connections 0-32 UNF, /8, /4, 3/8, /2 Reusable thread seal, PTFE seal ring (Teflon ) - Pro-Fit Standard - Camozzi s all metal fittings

More information

Terminal Block Accessories

Terminal Block Accessories Kliptite (Quick onnect) - Single Row Specifications: Terminal lock ccessories Kliptite (Quick onnect) accept standard female wire terminals. These Klipties are ideal for applications that require a positive,

More information

Product Data. CAPVU Evaporator Coil A Coil --- Uncased Upflow, Downflow CAPVU

Product Data. CAPVU Evaporator Coil A Coil --- Uncased Upflow, Downflow CAPVU CAPVU Evaporator Coil A Coil --- Uncased Upflow, Downflow Product Data CAPVU A06002 The CAPVU evaporator coils incorporate proven standards for reliable system operation and performance throughout the

More information

Type M4 - SON - SO - MS

Type M4 - SON - SO - MS 9. REV. Type M - SON - SO - MS Aircaps Tank venting and water excluding aircaps. For installation on service tank air pipes. Inerted void spaces and ballast tanks In order to maintain inert gas pressure

More information

3-Way Mixing and Sequencing Globe Valves, Flared (5/8 in. O.D.) with Electric, Hydraulic, and Pneumatic Actuators

3-Way Mixing and Sequencing Globe Valves, Flared (5/8 in. O.D.) with Electric, Hydraulic, and Pneumatic Actuators lectric, Hydrulic, nd Pneumtic ctutors TL 1. Select Vlve ody including P ode (Vlve Size, v Rting, Port ode) or select Vlve ssemly correct (refer to Tle 3 nd Tle 3 lso) less ctutor ode (XXX) including the

More information

Cooling Water Flow Regulator

Cooling Water Flow Regulator Temperature controlled, indirectly and directly actuated diaphragm valves / seat valves Port size G 3/8 to G DN 0 to DN 0 ontinuous regulation High accuracy No auxiliary energy required Technical data

More information

Conversion Kit for: 7620 and 7820 Swing-Out Valves ft-lbs ft-lbs 8835/ ft-lbs

Conversion Kit for: 7620 and 7820 Swing-Out Valves ft-lbs ft-lbs 8835/ ft-lbs ISO 900 REGISTERED COMPANY HEAVY DUTY SWING-OUT VALVE 52 53 23 5 2 2 3 28 39 NOT USED WITH SZ HANDLE 2 NOT USED WITH SZ HANDLE 5 2 3 7 9 9 Premier Farnell Corporation. 20 All rights reserved. No portion

More information

Sequence Cartridge Valves

Sequence Cartridge Valves Sequene Vlves Type Pge Pilot Operted, lned Piston Diret ting with Reverse Flow Chek 7 Kik-down, Pilot Operted, lned Piston ir Controlled, Pilot Operted, lned Piston 9 Diret ting without Reverse Flow Chek

More information

PVC - WHITE PRESSURE FITTINGS PRODUCTS PRICE LIST INCLUDES: PVC SCHEDULE 40, CLASS 125, POOL/SPA, LASCOTITE, ULTRAFIX REPAIR COUPLINGS PRICE GROUP

PVC - WHITE PRESSURE FITTINGS PRODUCTS PRICE LIST INCLUDES: PVC SCHEDULE 40, CLASS 125, POOL/SPA, LASCOTITE, ULTRAFIX REPAIR COUPLINGS PRICE GROUP PRICE GROUP DESCRIPTION 01 SCH 40 PVC through 8 91 SCH 40 PVC 10" AND LARGER 96 CLASS 125 10 & 12 09 POOL AND SPA 14 LASCOTITE 15 ULTRAFIX REPAIR COUPLING DISCOUNT MULTIPLIER PRODUCTS PVC - WHITE PRESSURE

More information

/2" Heavy Duty Swing-Out

/2 Heavy Duty Swing-Out Premier Farnell Corporation. 0 All rights reserved. No portion of this can be reproduced without the express written consent of Premier Farnell Corporation. ISO 900 REGISTERED COMPANY We will not be responsible

More information

PR CYCLONE SECONDARY SHUTOFF

PR CYCLONE SECONDARY SHUTOFF EN PR CYCLONE SECONDARY SHUTOFF ORIGINAL INSTRUCTIONS CYCLONE SECONDARY SHUTOFF PR530 CYCLONE SECONDARY SHUTOFF PR330 CYCLONE SECONDARY SHUTOFF PR200-250 CYCLONE SECONDARY SHUTOFF PR150 TECHNICAL DATA

More information

HEAVY DUTY SWING-OUT VALVE

HEAVY DUTY SWING-OUT VALVE ISO 900 REGISTERED COMPANY Akron Brass Company. 20 All rights reserved. No portion of this can be reproduced without the express written consent of Akron Brass Company. We will not be responsible for:

More information

Solenoid valves Type EVUL

Solenoid valves Type EVUL Data sheet Solenoid valves EVUL EVUL solenoid valves are designed to fit into compact refrigeration systems. Available in servo operated versions they can be applied in liquid, suction, and hot gas lines.

More information

Eliminator Liquid line filter driers, Type DCL and DML

Eliminator Liquid line filter driers, Type DCL and DML MAKING MODERN LIVING POSSIBLE Eliminator Liquid line filter driers, Type DCL and DML Flare connection Solder connection (copper) REFRIGERATION & AIR CONDITIONING DIVISION Technical leaflet Contents Page

More information

Cipriani Harrison Valves Corp.

Cipriani Harrison Valves Corp. Butterfly Valve pplication Stainless steel hygienic butterfly valves are used in process piping systems for isolation and control. Butterfly valves operate either manually or automatically. Working Principle

More information

45 Flare Fittings. Copper Flare Bonnets and Gaskets. Copper Flare. Copper Flare Gaskets. * C Dimension: Copper Flare Seal Bonnet +/ 1/64

45 Flare Fittings. Copper Flare Bonnets and Gaskets. Copper Flare. Copper Flare Gaskets. * C Dimension: Copper Flare Seal Bonnet +/ 1/64 Copper Flare Bonnets and Gaskets Copper Flare Seal Bonnets Part Number Size Flare A (in) B (in) C (in) Box Qty Wt(lb) B1 3 A 04737 3/16 0.31 0.16 0.16 25 0.001 B1 4 A 00414 1/4 0.36 0.22 0.22 100 0.001

More information

HEAVY DUTY SWING-OUT VALVE

HEAVY DUTY SWING-OUT VALVE ISO 900 REGISTERED COMPANY HEAVY DUTY SWING-OUT VALVE 52 53 23 5 2 2 3 28 39 NOT USED WITH SZ HANDLE 2 NOT USED WITH SZ HANDLE 5 2 3 7 9 9 Premier Farnell Corporation. 20 All rights reserved. No portion

More information

Distinctive Characteristics

Distinctive Characteristics Distinctive haracteristics Miniature Toggles Series M ntirotation design, standard on noncylindrical levers, mates toggle and bushing; bottom of toggle has two fl atted sides which fit into a complementary

More information

Cartridge Valves Technical Information. Quick reference

Cartridge Valves Technical Information. Quick reference Quick reference Contents CPF0... 8. CP600-5... 8. CP60-5... 8. 066 handle kit... 8.5 MP06... 8.6 MP... 8.6 X05-FD0 Traction manifold... 8.9 X05-FD6 Traction manifold... 8.0 X05-FD0 Traction manifold...

More information

McQuay. Water Source Heat Pump. VF, VG, VP Vintage E, F, G. Last Manufactured: Replacement Parts List No Revision B 02/2017

McQuay. Water Source Heat Pump. VF, VG, VP Vintage E, F, G. Last Manufactured: Replacement Parts List No Revision B 02/2017 Replacement s List No. 055206700 Revision B 02/2017 McQuay Water Source Heat Pump VF, VG, VP 240-390 Vintage E, F, G Last Manufactured: 1992 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Viega PureFlow Press Zero Lead Fittings with Attached Sleeves For Use with Viega PureFlow PEX Tubing. Potable Water. Residential Fire Sprinkler.

Viega PureFlow Press Zero Lead Fittings with Attached Sleeves For Use with Viega PureFlow PEX Tubing. Potable Water. Residential Fire Sprinkler. Viega PureFlow Press Zero Lead Fittings with Attached Sleeves For Use with Viega PureFlow PEX Tubing Project: Engineer: Contractor: Submitted By: Potable Water Residential Fire Sprinkler Other 1 of 18

More information

PN LINE. PN Line. PX Line. PA Line. PU Line PX LINE. PV Line PA LINE & TUBINGS PU LINE PV LINE. Brass Push-in fittings

PN LINE. PN Line. PX Line. PA Line. PU Line PX LINE. PV Line PA LINE & TUBINGS PU LINE PV LINE. Brass Push-in fittings I NDEX PV LINE PX LINE PU LINE PA LINE & TUBINGS PN LINE Brass Push-in fittings Stainless Steel Push-in fittings Brass Standard fittings and Flexible Hoses Couplings and Multiple Connectors Function fittings

More information

Column w/laterals. Steel Column A992 50ksi Steel (see sheets 4-7)

Column w/laterals. Steel Column A992 50ksi Steel (see sheets 4-7) olumn w/ SOREOR HEIGHT WITH ddtional display area consisting signs, arches, message centers or video above or below the scoreboard. (see sheets -6) for column and pier sizing) TOP SOREOR SETION Overall

More information

FOR CAN-AM ATV s P/N ASSEMBLY / OWNERS MANUAL

FOR CAN-AM ATV s P/N ASSEMBLY / OWNERS MANUAL MID-MOUNT KIT FOR CAN-AM ATV s P/N 15-7580 ASSEMBLY / OWNERS MANUAL Application PLOW PUSH FRAME NO. 15-0070, 33-0000 or 33-0070 Before you begin, please read these instructions and check to be sure all

More information

PVC - WHITE PRESSURE FITTINGS L40P EFFECTIVE OCTOBER 1, 2018 REVISED PRODUCTS PRICE LIST

PVC - WHITE PRESSURE FITTINGS L40P EFFECTIVE OCTOBER 1, 2018 REVISED PRODUCTS PRICE LIST PRICE GROUP DESCRIPTION 01 SCH 40 PVC through 8 91 SCH 40 PVC 10" AND LARGER 96 CLASS 125 10 & 12 09 POOL AND SPA 14 LASCOTITE 15 ULTRAFIX REPAIR COUPLING DISCOUNT MULTIPLIER PRODUCTS PVC - WHITE PRESSURE

More information

Vishay Dale Wirewound Resistors, Military, MIL-PRF Qualified, Type RE, Aluminum Housed, Chassis Mount FEATURES RESISTANCE RANGE 18546

Vishay Dale Wirewound Resistors, Military, MIL-PRF Qualified, Type RE, Aluminum Housed, Chassis Mount FEATURES RESISTANCE RANGE 18546 RH, NH FETURES Molded construction for total environmental protection omplete welded construction Meets applicable requirements of MIL-PRF-18546 vailable in non-inductive styles (type NH) with ryton- Perry

More information

P303 Pressure Regulator

P303 Pressure Regulator P0 Pressure Regulator Minimize Sudden Downstream Load Change Wide Pressure Ranges Integral Monitoring The BelGAS P0 and P0H gas pressure reducing regulators are available with a true monitor regulator,

More information

AIR COOLED CONDENSING UNIT

AIR COOLED CONDENSING UNIT NEW EVOLUTION SERIES AIR COOLED CONDENSING UNIT OUTDOOR AIR COOLED CONDENSING UNIT ORIGINAL MANUFACTURED EQUIPMENT NEW EVOLUTION 7 & 8 SERIES BA-506-5 AUS Evolution Air Cooled Condensing Unit Series Content

More information

M O D U L E - 3A Model A10V0 Piston Pump Manual A10V0 PUMP. Features

M O D U L E - 3A Model A10V0 Piston Pump Manual A10V0 PUMP. Features T E C H N I C A L I N F O R M A T I O N M A N U A L F O R T H E A 1 0 V 0 V A R I A B L E D I S P L A C E M E N T P U M P S A10V0 PUMP Features High Efficiency through load sensing (= fuel savings) Maximum

More information

INSTALLATION INSTRUCTIONS ATV SNOW PLOW Mounting Kit: PN Application: HONDA MODELS: 450S AND 450ES

INSTALLATION INSTRUCTIONS ATV SNOW PLOW Mounting Kit: PN Application: HONDA MODELS: 450S AND 450ES INSTALLATION INSTRUCTIONS ATV SNOW PLOW Mounting Kit: PN 37852 Application: HONDA MODELS: 450S AND 450ES Your safety, and the safety of others, is very important. To help you make informed decisions about

More information

CV3000 Series. Characterized Insert Control Valves

CV3000 Series. Characterized Insert Control Valves CV3000 Series Characterized Insert Control Valves The CV3000 Series is a v-type control valve for precise control allowing high pressure drop capability with straight-through flow and bubble-tight shut

More information

5900 Elite Comfort Recliner Parts List 2

5900 Elite Comfort Recliner Parts List 2 Page of 8 PRTS LIST Number Part Number 400530 STER, NYLON 3" TOTL LOK, (NO LONGER VILLE) 3 400540 STER, NYLON 3" DIRET. LOK, (NO LONGER VILLE) 566400 OLT-RRIGE ZIN /4-0 X /4 4 56604 NUT-/4-0 HEX NYLON

More information

PLOW MOUNT KIT FOR POLARIS RANGER P/N ASSEMBLY / OWNERS MANUAL

PLOW MOUNT KIT FOR POLARIS RANGER P/N ASSEMBLY / OWNERS MANUAL PLOW MOUNT KIT FOR POLARIS RANGER P/N 34-3010 ASSEMBLY / OWNERS MANUAL Application PLOW PUSH FRAME NO. 34-0000 or 34-0070 Before you begin, please read these instructions and check to be sure all parts

More information

Rotary Switches AC09, 16 and 32

Rotary Switches AC09, 16 and 32 09, 16 and 32 igital code output type escription FUJI series rotary switches offer a wide choice of output codes. They feature sliding u-flashed contacts for high contact reliability. Inhibitor and parity

More information

MX Series COMPACT AND USER FRIENDLY. Metal Tube Type Variable Area Flowmeter OUTLINE STANDARD SPECIFICATION MODEL CODE MX-400, MX-71 MX-52E

MX Series COMPACT AND USER FRIENDLY. Metal Tube Type Variable Area Flowmeter OUTLINE STANDARD SPECIFICATION MODEL CODE MX-400, MX-71 MX-52E OMPT ND USER FRIENDLY MX Series Metal Tube Type Variable rea Flowmeter OUTLINE MX Series flowmeter is the metal tube type variable area flowmeter having the unified face-to-face dimension. The compact

More information

INSTALLATION INSTRUCTIONS ATV SNOW PLOW Mounting Kit: PN Application: HONDA 300

INSTALLATION INSTRUCTIONS ATV SNOW PLOW Mounting Kit: PN Application: HONDA 300 INSTALLATION INSTRUCTIONS ATV SNOW PLOW Mounting Kit: PN 37850 Application: HONDA 300 Your safety, and the safety of others, is very important. To help you make informed decisions about safety, we have

More information

ENH4X. Product Specifications HORIZONTAL EVAPORATOR COILS ALL CASED N COIL MODELS WARRANTY*

ENH4X. Product Specifications HORIZONTAL EVAPORATOR COILS ALL CASED N COIL MODELS WARRANTY* ENVIRONMENTALLY SOUND REFRIGERANT ENH4X Product Specifications HORIZONTAL EVAPORATOR COILS ALL CASED N COIL MODELS 2 thru 5 Tons Available for environmentally sound R 410A systems Copper tube / aluminum

More information

Chapter 6. Hydraulic cylinders/rams (linear motors), and Lines/fittings. - Transforms the flow of a pressurized fluid into a push or pull of a rod.

Chapter 6. Hydraulic cylinders/rams (linear motors), and Lines/fittings. - Transforms the flow of a pressurized fluid into a push or pull of a rod. Chapter 6. Hydraulic cylinders/rams (linear motors), and Lines/fittings - Transforms the flow of a pressurized fluid into a push or pull of a rod. 6. Single cting Rams Gravity, spring, etc. can force piston

More information

98 Series Backpressure Regulators and Relief Valves

98 Series Backpressure Regulators and Relief Valves 9 Series Backpressure Regulators and Relief Valves Bulletin.:9 November 09 W TYPE 9H W TYPE 9LD Figure. Typical 9 Relief Valves Introduction W TYPE 9HD The 9 Series (Figure ) is used for backpressure or

More information

INSTALLATION INSTRUCTIONS ATV SNOW PLOW Mounting Kit: PN Application: HONDA 400

INSTALLATION INSTRUCTIONS ATV SNOW PLOW Mounting Kit: PN Application: HONDA 400 INSTALLATION INSTRUCTIONS ATV SNOW PLOW Mounting Kit: PN 37851 Application: HONDA 400 Your safety, and the safety of others, is very important. To help you make informed decisions about safety, we have

More information

Conductivity sensor for hygienic applications

Conductivity sensor for hygienic applications Conductivity sensor for hygienic applications Type 8221 can be combined with Perfect for demanding applications in the hygienic industry (CIP and SIP compatible) Variants available for usage over a wide

More information

product manual H-4204 Proving Ring Penetrometer

product manual H-4204 Proving Ring Penetrometer 05.09 product manual H-4204 Proving Ring Penetrometer nnmm Handle Proving Ring Extension Rod Coupler Penetration Rod Cone Figure #1 General Information The Proving Ring Penetrometer is a cone type of penetrometer

More information

579(XX).(X)(X)(X)(X) Modularized Roof Top Air Conditioner

579(XX).(X)(X)(X)(X) Modularized Roof Top Air Conditioner When ordering parts, always state: MODEL NO. - PRODUT NO. - QUANTITY - PART NUMBER - DESRIPTION For Electric Details also state: VOLTAGE - WATTAGE USA SERVIE OFFIE Dometic orporation 0 Industrial Parkway

More information

Configurations & Parts Identification

Configurations & Parts Identification Suspension Series Configurations & Parts Identification Advancing the Practical Application of Suspension Technology Springfield, MO n (800) 654-8824 n (417) 862-5012 Fax (417) 862-2317 n www.hutchensindustries.com

More information

Turbine Meter TRZ 03 PRODUCT INFORMATION. Reliable Measurement of Gas

Turbine Meter TRZ 03 PRODUCT INFORMATION. Reliable Measurement of Gas Turbine Meter TRZ 0 PRODUCT INFORMATION Reliable Measurement of Gas TURBINE METER TRZ 0 Method of operation, Construction Method of operation The TRZ 0 turbine meter is a flow meter suitable for gas measurement

More information

ASPT Series. Multi-Position, Internal TXV. Air Handler 1½ to 5 Tons

ASPT Series. Multi-Position, Internal TXV. Air Handler 1½ to 5 Tons Series Multi-Position, Internal TXV Product Features Internal factory-installed thermal expansion valves for cooling and heat pump applications Direct drive, multi-speed ECM blower motor All-aluminum evaporator

More information

6.0 EC-SERIES CUBERS EC200-EC300-EC400-EC500-EC606 AIR, WATER AND REMOTE

6.0 EC-SERIES CUBERS EC200-EC300-EC400-EC500-EC606 AIR, WATER AND REMOTE 6.0 EC-SERIES CUBERS EC200-EC300-EC400-EC500-EC606 AIR, WATER AND REMOTE Item EC EC EC EC EC EC Code Part Description Part Number GRP 200 300 400 406 500 606 AIR COOLED 5 Air Condenser 9141048-01 AC X

More information

Instructions for Parts Books

Instructions for Parts Books Instructions for Parts Books The heading at the top of the page will be the same for the picture of the parts at it is for the page with the part numbers. Definition of column headings on part number pages:

More information

Edition 3 September Air Angle Wrench and Nut Runner. QA6 and QA8 Series. Parts Information. Save These Instructions

Edition 3 September Air Angle Wrench and Nut Runner. QA6 and QA8 Series. Parts Information. Save These Instructions 660072 Edition 3 September 2007 Air Angle Wrench and Nut Runner QA6 and QA8 Series Parts Information Save These Instructions Module Exploded Diagram 7 5 9 7 2 9 50 3 8 3 38 39 8 9 20 2 33 22 23 3 2 3 37

More information

AIR COOLED CONDENSING UNIT

AIR COOLED CONDENSING UNIT EVOLUTION SERIES AIR COOLED CONDENSING UNIT OUTDOOR AIR COOLED CONDENSING UNIT ORIGINAL MANUFACTURED EQUIPMENT Evolution Series BA-503-3 AUS Evolution Air Cooled Condensing Unit Series Content Page Explanation

More information

R- 410A R-22 Size (tons) Shipping Weight (lbs) WLAU184AA 1-1/ WLAU182AA 1-1/ WLAU244AA. Model /2

R- 410A R-22 Size (tons) Shipping Weight (lbs) WLAU184AA 1-1/ WLAU182AA 1-1/ WLAU244AA. Model /2 EVAPORATOR COILS A COIL - UNCASED R- 410A or R- 22 SYSTEMS 1 1/2 5 Tons WLAU Use of the AHRI Certified TM Mark indicates a manufacturer s participation in the program. For verification of certification

More information

PlowGuard - Plow Balance System. Patent No. 6,467,553 PART NUMBER: SG REV: C DATE: 07/03/14. List of Included Documents

PlowGuard - Plow Balance System. Patent No. 6,467,553 PART NUMBER: SG REV: C DATE: 07/03/14. List of Included Documents PlowGuard - Plow alance System escription List of Included ocuments rawing Numbers Patent No.,7, Initial Setup/djustment Procedure Plow alance Valve ½ load sense Plow alance Valve full load sense ustom

More information

Viega PEX Press Zero Lead Fittings with Attached Sleeves For Use with Viega PureFlow Tubing. Potable Water. Residential Fire Sprinkler.

Viega PEX Press Zero Lead Fittings with Attached Sleeves For Use with Viega PureFlow Tubing. Potable Water. Residential Fire Sprinkler. Viega PEX Press Zero Lead Fittings with Attached Sleeves For Use with Viega PureFlow Tubing Project: Engineer: Contractor: Submitted By: Potable Water Residential Fire Sprinkler Other 1 of 15 Viega PEX

More information

High Pressure Ball Valves

High Pressure Ball Valves High Pressure all Valves 0,, 0, 0,000 psi (0 bar),000 psi (0 bar) 0,000 psi ( bar) ITOK Group ITOK GmbH (Headquarter) Sprendlinger Landstr., 0 Offenbach am Main, Germany Tel.: + 00 ax: + 00 ITOK, Inc.

More information

A.R.M. 52 PLOW With QUICK ATTACH MOUNTING SYSTEM MODEL NUMBER BLACK MODEL NUMBER GRAY. Owner s Manual

A.R.M. 52 PLOW With QUICK ATTACH MOUNTING SYSTEM MODEL NUMBER BLACK MODEL NUMBER GRAY. Owner s Manual 70 8TH AVE W PO BOX 7 SPENCER, IA 0 PHONE: 7-6-9 FAX: 7-6-08 SERVICE: 800-8- E-MAIL: ccac@cyclecountry.com www.cyclecountry.com A.R.M. PLOW With QUICK ATTACH MOUNTING SYSTEM MODEL NUMBER 0-00 BLACK MODEL

More information

405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test Data Book and Flow Handbook

405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test Data Book and Flow Handbook Reference Manual 405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test Book and Flow Handbook www.rosemount.com Reference Manual 405 and 1595 405 Compact Orifice Series and 1595 Conditioning

More information

KM-1600SWH KM-1600SRH KM-1600SWH3 KM-1600SRH3

KM-1600SWH KM-1600SRH KM-1600SWH3 KM-1600SRH3 NO. ISSUED: REVISED: 71193 OCT. 2, 2001 JAN. 27, 2003 HOSHIZAKI STACKABLE CRESCENT CUBER MODELS KM-1600SWH KM-1600SRH KM-1600SWH3 KM-1600SRH3 PARTS LIST KM-1600SWH L-0 June, 2001 M-0 Feb., 2002 M-1 Feb.,

More information

Singer. Incremental Comfort Systems. K, EK Vintage F. Last Manufactured: Replacement Parts List No Revision C 04/2012

Singer. Incremental Comfort Systems. K, EK Vintage F. Last Manufactured: Replacement Parts List No Revision C 04/2012 Replacement Parts List No. 055231000 Revision C 04/2012 Singer Incremental Comfort Systems K, EK 07-15 Vintage F Last Manufactured: 1976 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Part /Assy Parts List. Production Order. Badge, Perkins/Sabre M215C. Description

Part /Assy Parts List. Production Order. Badge, Perkins/Sabre M215C. Description Badge, Perkins/Sabre M215C Part /Assy 5242 S000000 0002 2 X X 33213 BADGE, HEADER TANK, PERKINS/SABRE M21 S000000 1 P Badge, manifold, Perkins/Sabre(34314) Part /Assy 6696 S000000 0001 1 X X 34314 BADGE,

More information

405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test Data Book and Flow Handbook

405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test Data Book and Flow Handbook 405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test Book and Flow Handbook www.rosemount.com 405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test Book NOTICE Read

More information

Bettis RGS F-Series. Quarter-Turn Spring-Return (SR) and Double-Acting (DA) Pneumatic Actuators. Product Data Sheet RGS Rev.

Bettis RGS F-Series. Quarter-Turn Spring-Return (SR) and Double-Acting (DA) Pneumatic Actuators. Product Data Sheet RGS Rev. Bettis RGS F-Series Quarter-Turn Spring-Return (SR) and Double-Acting (DA) Pneumatic Actuators Output Torques to 500,000 in-lb (56,492 N m) Ductile Iron or Stainless-Steel Construction Temperatures from

More information

LES. Single-stage end-suction pumps Identification Type key

LES. Single-stage end-suction pumps Identification Type key Contents Singlestage endsuction pumps Identification Type key Product data Introduction Applications Features and benefits Performance range pole pole 6 pole Construction Sectional drawing Construction

More information

LO1 SERIES. compact direct solenoid actuated valves

LO1 SERIES. compact direct solenoid actuated valves SRS compact direct solenoid actuated valves 0 d i r e c t s o l e n o i d a c t u a t e d v a l v e s T N T................................................... V V O S T O N........................................

More information

42C/V. Fan Coil Unit 42C/V

42C/V. Fan Coil Unit 42C/V 2/V Fan oil Unit 2/V arrier makes the world a better place to live by creating a comfortable, productive and healthy environment regardless of climate. It is our mission is to be customer s first choice

More information

Serie B2.1. Flanged ductile iron ball valve. made in. Application fields. Shut-off valves E U R O P E. 18

Serie B2.1. Flanged ductile iron ball valve. made in. Application fields. Shut-off valves E U R O P E. 18 erie B. Flanged ductile iron ball valve BRanDOni made in E U R O P E Application fields WATER CONdITIONING GA EATING INdUTRY FIRE FIGTING www.brandoni.it erie B. eries B. valves are shut-off ball valves

More information

Fluid Cooling Shell & Tube EC Series

Fluid Cooling Shell & Tube EC Series Fluid ooling hell & Tube eries 01 O & TL OTTIO erformance otes ugged steel shell construction /" tube size Larger shell diameter than K,.0" maximum diameter High flow capacity & performance High efficiency

More information

08.16 Balancing Valves

08.16 Balancing Valves 08. Tour & ndersson calibrated balancing valves offer a reliable, simple and cost effective way to measure and balance all flow rates. Full throttling range is achieved by, 8,,, 0 or full turns of the

More information

THE LOSMANDY G-11 MOUNT

THE LOSMANDY G-11 MOUNT Checking the parts THE LOSMANDY G-11 MOUNT Depending on which accessories you ordered, your G-11 mount was shipped in four or more boxes. The contents of each box are as follows: Equatorial Mount Adjustable

More information

Solenoid valve Types CSV 2 - CSV 22 (NC) and solenoid coil

Solenoid valve Types CSV 2 - CSV 22 (NC) and solenoid coil Data sheet Solenoid valve s CSV 2 - CSV 22 (NC) and solenoid coil CSV is a direct or servo-operated solenoid valve for liquid, suction, and hot gas lines with fluorinated refrigerants. CSV valves are for

More information

C7400A and C7400C Enthalpy Sensors

C7400A and C7400C Enthalpy Sensors 70 and 70 Enthalpy Sensors PROUT T FETURES PPLITION The 70 Enthalpy Sensor is used with the economizer logic modules with the,,, and performance curves; the 70 sensor is used with the logic modules with

More information

Service Information Letter SIL # 017

Service Information Letter SIL # 017 Service Information Letter SIL # 017 Trunnion Adjustment - Double Barrels Only Equipment: Double Barrels With Sloped Trunnions Date Issued: 9-24-03 Additional Reference: SIL # 016 Revised: Revision #:

More information

(HSI) LIMITED WARRANTY

(HSI) LIMITED WARRANTY ama The Payne PG8MAA/JAA 80% AFUE Gas Furnaces feature 4-way multipoise design and through-the-furnace downflow venting. The PG8MAA/JAA furnaces are approved f use with natural propane gas, and the PG8JAA

More information

1. Introduction. 1.1 Overview of Study:

1. Introduction. 1.1 Overview of Study: 1. Introduction 1.1 Overview of Study: Hot and cold fluid passing through long pipes causes thermal expansion and contraction in the piping system. The fluid passing through pipes also creates fluctuations

More information

Cold and freeze protection of blueberries in Florida. Dr. Dorota Z. Haman Agricultural and Biological Dept. University of Florida

Cold and freeze protection of blueberries in Florida. Dr. Dorota Z. Haman Agricultural and Biological Dept. University of Florida Cold and freeze protection of blueberries in Florida Dr. Dorota Z. Haman Agricultural and Biological Dept. University of Florida Frost versus Freeze Frost is a local condition which occurs in your area

More information

Innovation in. Motionless Mixers

Innovation in. Motionless Mixers Innovation in Motionless Mixers Ross Motionless Mixers PIONEERING TECHNOLOGY. INCOMPARABLE QUALITY. WORLDWIDE LEADERSHIP. Serving all the process industries in virtually every industrialized country around

More information

STATIC GAS MONITOR Type SGM/DEW Revision A of 20 aprile 2016

STATIC GAS MONITOR Type SGM/DEW Revision A of 20 aprile 2016 APPLICATIONS Moisture monitoring of air or gas (SF6) Suitable for indoor or outdoor Industrial, medical or aerospace fields HIGHLIGHTS High voltage circuit breakers commonly used for distribution and transmission

More information

END4X, ENW4X, ENA4X. Product Specifications VERTICAL EVAPORATOR COILS ALL N COIL MODELS CASED N COILS UNCASED N COILS ENA4X WARRANTY*

END4X, ENW4X, ENA4X. Product Specifications VERTICAL EVAPORATOR COILS ALL N COIL MODELS CASED N COILS UNCASED N COILS ENA4X WARRANTY* ENVIRONMENTALLY SOUND REFRIGERANT VERTICAL EVAPORATOR COILS ALL N COIL MODELS 1½ thru 5 Tons Available for environmentally sound R 410A systems Copper tube / aluminum fin N coil with latest high tech fin

More information

/2 way valves (solenoid actuated diaphragm with forced lifting) 1/4... 2

/2 way valves (solenoid actuated diaphragm with forced lifting) 1/4... 2 / way valves (solenoid actuated diaphragm with forced lifting) /4... Damped operation Operation without differential Suitable for vacuum igh flow rate For systems with low or fluctuating Brass body Wide

More information

405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test Data Book and Flow Handbook

405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test Data Book and Flow Handbook 405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test Book and Flow Handbook www.rosemount.com 405 and 1595 405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test

More information

PLOW MOUNT KIT FOR YAMAHA VIKING P/N ASSEMBLY / OWNERS MANUAL. Application PLOW PUSH FRAME NO or

PLOW MOUNT KIT FOR YAMAHA VIKING P/N ASSEMBLY / OWNERS MANUAL. Application PLOW PUSH FRAME NO or PLOW MOUNT KIT FOR YAMAHA VIKING P/N 34-5020 ASSEMBLY / OWNERS MANUAL Application PLOW PUSH FRAME NO. 34-0000 or 34-0070 Before you begin, please read these instructions and check to be sure all parts

More information

6940 Elite Care Cliner Parts List 3

6940 Elite Care Cliner Parts List 3 Page of 7 () Number Part Number VERSION,F 400550 STER, NYLON 5" TOTL LOK (NO LONGER VILLE),,F 400560 STER, NYLON 5" IRETNL LOK (NO LONGER VILLE) G 00560K OSOLETE IRETIONL STER REPLEMENT KIT VERSION 400575

More information

TOTAL HEAD, N.P.S.H. AND OTHER CALCULATION EXAMPLES Jacques Chaurette p. eng., June 2003

TOTAL HEAD, N.P.S.H. AND OTHER CALCULATION EXAMPLES Jacques Chaurette p. eng.,   June 2003 TOTAL HEAD, N.P.S.H. AND OTHER CALCULATION EXAMPLES Jacques Chaurette p. eng., www.lightmypump.com June 2003 Figure 1 Calculation example flow schematic. Situation Water at 150 F is to be pumped from a

More information

Freescale Semiconductor

Freescale Semiconductor Freescale Semiconductor Pressure Rev 14, 10/2008 + 10 kpa Uncompensated Silicon Pressure The series silicon piezoresistive pressure sensors provide a very accurate and linear voltage output, directly proportional

More information