1 Medical Oxygen Regulators 55B Range regulators are designed for mobile use in demanding conditions. The main material of manufacture is brass. Proven durability means these regulators are sold with a 5 year service interval and 5 year (return to Meditech) warranty. The recommended product life is 10 years. 55SL Range regulators are designed for mobile use where light weight is important. The main material of manufacture is aluminium alloy, but with a brass high pressure oxygen path for safety. These regulators are sold with a 5 year service interval and 5 year (return to Meditech) warranty. The recommended product life is 10 years. flow rate indicator flow rate selector, 0-15 lpm on this model outlet barbed firtree style Doc 84M, Issue D, 12/October/ Illustrated attached to cylinder Cylinder contents pressure gauge Regulator input fitting. Pin index illustrated Medical oxygen output fitting (2 power on this model, BS5682,1988 Oxygen Schrader (UK))
2 Oxygen therapy option: Oxygen therapy is easily chosen by rotating the " selector" (1). The is indicated in the display window (2). For our 0-15 lpm models choose from 0, ½,1, 2, 3, 4, 6, 8, 10 or 15 litres per minute. For our 0-25 lpm models choose from 0, ½,1, 2, 3, 4, 6, 8, 10,15 and MAX (25) litres per minute. Oxygen at the chosen flow is discharged from the outlet (3). The outlet is designed so that plastic oxygen tubing can be securely held in place on the barbed fir-tree style connector. Alternative connection (4) is the threaded connector 9/16-18 for attaching a humidifier or other accessory. Meditech gauges: Designed for high visibility in daylight and with a luminous face for night use. The gauge needle spans over 180 degrees between 200 bar and zero, clearly indicating the pressure. The gauge also features coloured segments, green indicating the range of full cylinders and red for empty. The energy release to rear of the gauge enhances user safety. A rubber protective boot surrounds the gauge for added protection against damage.
3 When ordering, please include the following description information: Medical oxygen regulator 55B (Brass) or 55SL (Super Light) Input fitting type, (for connection to cylinder valve) Output fitting (power outlet) type. Number of power 1) One front, 2) Two, 3) One rear Oxygen therapy: Yes or No Oxygen therapy s: 0-15lpm or 0-25lpm Oxygen therapy outlet fitting: barbed fir-tree style or threaded connector 9/16-18 system for 4 bar output medical oxygen regulators with input pressure up to 200 bar: Body type (all 4 bar, medical oxygen) B Pin index (uni-body) with therapy B Pin index (uni-body) without therapy B International (nut) fitting with therapy B International (nut) fitting without therapy SL Pin index (uni-body) with therapy SL Pin index (uni-body) without therapy SL International (nut) fitting with therapy SL International (nut) fitting without therapy Input fitting (connects to cylinder valve) 00 Pin index (oxygen) BS EN ISO407:2004, (CGA-870, USA) 01 Bull-nose (UK) 02 Bull-nose (Benelux) 03 W DIN 477, No.9 05 CGA-540 (USA) 06 G11 07, 08 Not available 20 Lebanese Bull-nose directive. bbb-iioo-nt Medical oxygen output fitting (power connector) 00 None fitted (blanking) 01 BS5682, 2015 Oxygen Schrader (UK) 02 DISS 1240 (USA) 03 AGA SS :2004 (Swedish) 04 DIN :2004 Part 2 (Hayer) (German) 05 AFNOR NF S90-116:1988 (2006)(French) 06 Japanese 07 SIS (Sleeved Index System) AS2902:1986 (Australian) 10 JIS T7101:2006 (Japanese) 11 Ohmeda (USA) 14 UNIFOR (Italian) 08, 09, 12, 13, Not available Number of output fittings 0 None 1 One (to front) 2 Two 3 One (to rear) Please contact our office for any assistance required. output type (when fitted) 0 flows 0-15 lpm (fir tree connector) 1 flows 0-25 lpm (fir tree connector) 2 flows 0-15 lpm (threaded connector 9/16-18 for humidifier) 3 flows 0-25 lpm (threaded connector 9/16-18 for humidifier) 0 When no therapy also use 0
4 55B Oxygen Regulator, Pin index input (Unibody), only SL Oxygen Regulator, Pin index input (Unibody), only B Oxygen Regulator, Pin index input (Unibody), BS Schrader output. (No therapy) SL Oxygen Regulator, Pin index input (Unibody), BS Schrader output. (No therapy)
5 55B Oxygen Regulator, Pin index input (Unibody), BS Schrader output, SL Oxygen Regulator, Pin index input (Unibody), BS Schrader output,
6 55B Oxygen Regulator, BS Bullnose input, only SL Oxygen Regulator, BS Bullnose input, only B Oxygen Regulator, BS Bullnose input, BS Schrader output. (No therapy) SL Oxygen Regulator, BS Bullnose input, BS Schrader output. (No therapy)
7 55B Oxygen Regulator, BS Bullnose input, BS Schrader output, SL Oxygen Regulator, BS Bullnose input, BS Schrader output,
8 meditech Medical Oxygen Regulators Meditech 55B and 55SL regulators are Class IIb medical devices. The regulators shown in this brochure are designed to function on an inlet pressure (oxygen cylinder working pressure) up to 200 bar. The nominal output pressure is 4 bar. All regulators incorporate a sintered inlet filter and have an integral pressure relief valve for safety. Our regulators in this range are sold with a five year return to manufacturer warranty against manufacturing defect. B.N.O.S. Meditech Ltd. 9 Fifth Avenue, Bluebridge Industrial Estate, Halstead, Essex, CO9 2SZ England, UK. Tel: +44 (0) Fax: +44 (0) sales@meditech.uk.com These products are part of a series of oxygen and resuscitation products available, if the product you require is not shown here, or if you require more information please contact your distributor or the manufacturer B.N.O.S. Meditech Ltd. UK Patent No USA Patent No & Canada Patent No European Patent No Specifications may be subject to change without notice. B.N.O.S. Meditech Ltd. terms and conditions of sale apply. A copy is available on application or from our web site.
5/2-5/3 SPOOL VALVES MULTIFUNCTION air operated or solenoid air operated with subbase ISO 5599/1 sizes 1, 2 and 3
/ - / SPOOL VALVES MULTIFUNCTION air operated or solenoid air operated with subbase ISO 99/ sizes, and Series Fluids air or inert gas, filtered, lubricated or not Operating pressure Pilot pressure Ambient
More informationAccumulators Virginia KMP Suction Line Accumulators
Accumulators Virginia KMP Suction Line Accumulators The Virginia KMP suction line accumulator's purpose is to prevent excessive quantities of liquid refrigerant and oil from returning to the compressor.
More informationLOW E SATINÉ 5500 LOW E
SCREEN LOW E INTELLIGENT FABRICS FOR SOLAR PROTECTION Width: 240 cm www.mermet.co.uk LOW E THERMAL SHIELD FOR INTERNAL BLINDS 76% OF SOLAR REFLECTANCE 17% EMISSIVITY for thermal comfort all year round
More informationE 094 E 103 E 143. Tank top mounting Connection up to G1 Nominal flow rate up to 135 l/min e
R e t u r n F i l t e rs E 094 E 103 E 143 Tank top mounting Connection up to G1 Nominal flow rate up to 135 l/min 20.30-5e D e s c r i p t i o n Application In the return line circuits of hydraulic systems.
More information- compressed air plants (refrigerating/adsorption dryers) - granulate dryers - medical gases - non-corrosive gases, e. g. nitrogen
INSTRUCTION MANUAL FA 510 The CS dew point sensor FA 510 with 3-wire technology 4 20 ma and RS 485 output enables a reliable and long-term stable monitoring of the dew point in industrial applications
More informationDM70 Hand-Held Dewpoint Meter for Spot-Checking Applications
DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications The Vaisala DRYCAP Hand-Held Dewpoint Meter DM70 offers accurate and fast measurement for industrial dewpoint applications, such as compressed
More informationINTERNATIONAL STANDARD
INTERNATIONAL STANDARD ISO 8426 Second edition 2008-02-01 Hydraulic fluid power Positive displacement pumps and motors Determination of derived capacity Transmissions hydrauliques Pompes et moteurs volumétriques
More informationFLT5A FLT5A. abc. abc. Thermometer User Guide. Thermometer User Guide. Internet:
abc instruments international FLT5A Thermometer Land Instruments International Dronfield, S18 1DJ England Telephone: (1246) 417691 Facsimile: (1246) 41585 Email: infrared.sales@landinst.com Internet: www.landinst.com
More informationIBV Series Z Alloy Steel Inverted Bucket Vertical Steam Trap
Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without
More informationIBV Series C Carbon Steel Inverted Bucket Vertical Steam Trap
Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without
More informationOperating Instructions for Digital Manometer. Model: MAN-SD
Operating Instructions for Digital Manometer Model: MAN-SD 1. Contents 1. Contents...2 2. Note...3 3. Instrument Inspection...3 4. Regulation Use...4 5. Operating Principle...4 6. Mechanical Connection...5
More informationPressure Transmitter ED 701
Pressure Transmitter ED 701 Hygienic and industrial process connections Zero setting function Accuracy < 0.1% FS Quick response time < 25 ms High long-term stability Excellent repeatability Active compensation
More informationDMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm
DMP Pi Precision Pressure Transmitter pressure ports and process connections with flush welded stainless steel diaphragm accuracy according to IEC 600: 0, % FSO Nominal pressure from 0... 00 mbar up to
More informationDMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm
DMP Pi Precision Pressure Transmitter pressure ports and process connections with flush welded stainless steel diaphragm accuracy according to IEC 600: 0, % FSO Nominal pressure from 0... 00 mbar up to
More informationDS 200P. Electronic Pressure Switch. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm
Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm accuracy according to IEC 600: standard: 0. % FSO option: 0. % FSO Nominal pressure from 0... 00 mbar up to 0... 0 bar
More informationLOW E SATINÉ 5500 LOW E
SCREEN LOW E INTELLIGENT FABRICS FOR SOLAR PROTECTION COLLECTION 2015 2018 Width: 240 cm www.sunscreen-mermet.com LOW E THERMAL SHIELD FOR INTERNAL BLINDS 78% OF SOLAR REFLECTANCE 15% EMISSIVITY for thermal
More informationTECHNOLOGY IN MOTION MACO EMOTION HANDLES. A Sense of Elegance RHAPSODY
TECHNOLOGY IN MOTION MACO HANDLES A Sense of Elegance RHAPSODY Clarity of design over the entire program Door and window handles are essential stylistic and functional elements. This is why it is important
More informationzehnder stratos CS CS CS CSW CSW Product Overview Model Code (example)
Product Overview Model Code (example) CS-15-19 Depth (cm) eight (cm) CS = Convector Stratos CS = Convector Stratos with rear dummy panel CS-..-10 CS-..-13 No. of panels: 2 No. of fins: 2 Depth: 98mm eight:
More informationMetz Syn 10 Reaction Station
Metz Syn 10 Reaction Station For parallel chemistry, process development and reaction optimisation Simultaneously carry out 10 reactions, but each with a different temperature, from -30 C to +150 C...
More informationDMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm
DMP P Industrial Pressure Transmitter Process Connections With Flush Welded Stainless Steel accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 % FSO Nominal pressure from 0... 00 mbar up
More informationDiscontinued BL Series, Cross-Reference to MicroKing Series
4908 Discontinued BL Series, Cross-Reference to ISSUED: April, 2000 Discontinued BL Series, Cross-Reference to BL Series BL Valve will be discontinued December, 2000 General Notes: Parker BL Valve is the
More informationMust Read Before Installation TadPoleTM Safety and Warnings
Must Read Before Installation TadPoleTM Safety and Warnings The recommendations, requirements, rules, and instructions of your Vehicle's Roof-Top Rack System should ALWAYS be followed. The TadPole TM,
More informationOperating instructions Magnetic-inductive flow meter SM6x04 SM7x04 SM8x04
Operating instructions Magnetic-inductive flow meter SM6x04 SM7x04 SM8x04 UK 80223776 / 00 11 / 2018 Contents 1 Preliminary note...3 2 Safety instructions...4 3 Functions and features...4 4 Function...5
More informationCHINA MP FILTRI P.O. Box Shanghai Phone: Fax:
FMP 038 uk 6-07-006 9:34 Pagina (,) New Headquarters : MP FILTRI S.p.A. Italy Via Maggio, n. 3 0060 Pessano con Bornago (Milano) Italy Tel. +39.0/95703. Fax +39.0/9574497-9574088 email: sales@mpfiltri.com
More informationSemi-automatic titrators PH-Burette. A great ph-meter with integrated burette. Incredible price! Infinite possibilities
Semi-automatic titrators PH-Burette. A great ph-meter with integrated burette. Incredible price! Infinite possibilities instruments 5 YEARS G U A R A N T E E Quality at a reasonable price The optimum combination
More informationDM70 Hand-Held Dewpoint Meter for Spot-Checking Applications
DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications The Vaisala DRYCAP Hand-Held Dewpoint Meter DM70 offers accurate and fast measurement for industrial dewpoint applications, such as compressed
More informationAIR PREPARATION. ELECTRONICALLY CONTROLLED PRESSURE REGULATING VALVE (PROPORTIONAL PRESSURE REGULATING VALVE) SERIES control
AIR PREPARATION ELECTRONICALLY CONTROLLED PRESSRE REGLATING ALE (PROPORTIONAL PRESSRE REGLATING ALE) SERIES control Description Abb. Port size Recommended Type Data Sheet No. flow (l/min)* airfit tecno
More informationVD1 CLC. Small Valves DIN-range with a higher k v -value
0 EN - Small Valves DIN-range with a higher k v -value VD CLC Valve body made of brass, mat nickel-plated DN, DN 0 and DN Internally and externally threaded (Rp / R) conforming to ISO 7- Manual knob /
More informationCabinets G " integrated in upright Handle strip in side panel Easy solution for shortened doors
Overview... 0 Cabinets... 1 Cabinets Wall mounted cases... 2 Accessories for cabinets and wall mounted cases... 3 Climate control... 4 Desk-top cases... 5 Subracks/ 19" chassis... 6 02002002 Front panels,
More informationI n t h e a i r, o n l a n d,
I n t h e a i r, o n l a n d, a n d u n d e r t h e s e a. W e a r e p a s s i o n a t e a b o u t o u r h y d r a u l i c s. L e t u s s u r p r i s e y o u! During its fifty years of experience in the
More informationDirections for use
Directions for use 40070 40080 60050 70060 70076 80060 90060 900114 Fig. 1 Fig. 1A Fig. 2 Fig. 3 Fig. 4 Fig. 5 Fig. 6 Fig. 7 english ENGLISH DIRECTIONS FOR USE 1 Tripod Leg 2 Tripod Leg Adjusting Screw
More informationA.R.M. 52 PLOW With QUICK ATTACH MOUNTING SYSTEM MODEL NUMBER BLACK MODEL NUMBER GRAY. Owner s Manual
70 8TH AVE W PO BOX 7 SPENCER, IA 0 PHONE: 7-6-9 FAX: 7-6-08 SERVICE: 800-8- E-MAIL: ccac@cyclecountry.com www.cyclecountry.com A.R.M. PLOW With QUICK ATTACH MOUNTING SYSTEM MODEL NUMBER 0-00 BLACK MODEL
More informationField IT 50T Series Transmitters
Data Sheet SS/G/A_ Field IT 0T Series Transmitters gauge/absolute pressure transmitter Ranges: -00 to 0000kPa - to 00bar -. to 6000psi Base accuracy : 0.% (BFSL) Chemical Vapour Deposition (CVD) technology
More informationDMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor
DMP Industrial Pressure Transmitter for Low Pressure Stainless Steel Sensor accuracy according to IEC 60770: : 0.5 % FSO option: 0.5 / 0. % FSO Nominal pressure from 0... 00 mbar up to 0... 60 bar Output
More informationFVBSS fixed volume bottle
N FVBSS fixed volume bottle Sampling System The SENSOR Fixed Volume Bottle Sampling System (FVBSS) provides a repeatable fixed volume of sample during each sampling process without stopping flow of the
More informationAmphenol C 091 A/B/D. Circular Connectors. Amphenol-Tuchel Electronics GmbH
Amphenol C 091 A/B/D Circular Connectors Amphenol-Tuchel Electronics GmbH General information These connectors are designed and produced in conformity with the low-voltage directive (/3/EWG) respectively
More informationModular Style Air Combination. Assembled by simply tightening the screws
Modular Style Air Combination Series AC Assembled by simply tightening the screws High strength die cast bracket Drain cock for one push drain exhaust Oil needle for easy oil volume adjustments The improved
More informationED 701 General Industry Pressure Transmitter
ED 701 General Industry Pressure Transmitter Standard industrial process connections Complete range of electrical connections 4... 20 ma and Voltage outputs Accuracy: 0.1%, 0.2% and 0.4% FS Quick response
More informationPLOW MOUNT KIT FOR POLARIS RANGER P/N ASSEMBLY / OWNERS MANUAL
PLOW MOUNT KIT FOR POLARIS RANGER P/N 34-3010 ASSEMBLY / OWNERS MANUAL Application PLOW PUSH FRAME NO. 34-0000 or 34-0070 Before you begin, please read these instructions and check to be sure all parts
More informationQuick - connects. SQC Series, SFQC Series
Quick - connects QC eries, QC eries INTRUENTATION QUICK - CONNECT QC ERIE EATURE QUICK - CONNECT imple push-pull action to connect and disconnect lines-no tools required. Plug and body are available valved
More informationAmphenol. Amphenol-Tuchel Electronics GmbH. Circular Connectors C 091 A/B/D Series
Amphenol Amphenol-Tuchel Electronics GmbH Circular Connectors C 09 A/B/D Series The Company Amphenol-Tuchel Electronics GmbH is a member of the USA based Amphenol Corporation. With our own global presence
More informationOperating instructions Vortex flow meter. SVxxx / / 2015
Operating instructions Vortex flow meter SVxxx0 80229859 / 00 06 / 2015 Contents 1 Safety instructions...3 2 Functions and features...3 3 Function...4 4 Installation...4 5 Electrical connection...6 6 Operating
More informationINSTRUCTION MANUAL. Laser Diode Sarcomere Length. Aurora Scientific Inc. 360 Industrial Parkway South, Unit 4 Aurora, Ontario, Canada L4G 3V7
INSTRUCTION MANUAL Model 902A Laser Diode Sarcomere Length May 6, 2013, Revision 3 Copyright 2008-2013 Aurora Scientific Inc. Aurora Scientific Inc. 360 Industrial Parkway South, Unit 4 Aurora, Ontario,
More informationData Sheet / Instructions. Dewpoint MeterO
Data Sheet / Instructions Dewpoint MeterO Dewpoint Meter ISO 8502-4: Preparation of steel substrates before application of paints and related products. Tests for the assessment of surface cleanliness.
More informationInstallation guide 862 MIT / MIR
Installation guide 862 MIT / MIR in combination with: 864 MTT or 863 MRT or (dual) spot element November 2005 Part no. 4416.232_Rev3 Enraf BV PO Box 812 2600 AV Delft Netherlands Tel. : +31 15 2701 100
More informationVaisala DRYCAP Hand-Held Dewpoint Meter DM70. Fast Response - Low Maintenance
Vaisala DRYCAP Hand-Held Dewpoint Meter DM70 Fast Response - Low Maintenance DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications The Vaisala DRYCAP Hand- Held Dewpoint Meter DM70 offers accurate
More informationSeries Shrink Boot Adapters. Series Shrink Boot, EMI/RFI, Strain Relief. Series Shrink Boot, EMI/RFI, Shield Sock
Product Selection Guide How For a complete Table of Contents please see the last page of this book Series 310 - Shrink Boot Adapters The adapters in this section are designed to accommodate lipped-type
More informationHELLA. Linear slot diffuser. Ordering codes. HELLA - Linear diffuser. Linear Diffusers 1 / 18. Example of the ordering code HELLA B-0-0-AN
Linear Diffusers / 8 HELLA Linear slot diffuser Ordering codes HELLA - Linear diffuser HELLA - Number of slots... Diffuser length L (mm) ) Increment mm... Deflector colour Damper Diffuser construction
More informationPLOW MOUNT KIT FOR YAMAHA VIKING P/N ASSEMBLY / OWNERS MANUAL. Application PLOW PUSH FRAME NO or
PLOW MOUNT KIT FOR YAMAHA VIKING P/N 34-5020 ASSEMBLY / OWNERS MANUAL Application PLOW PUSH FRAME NO. 34-0000 or 34-0070 Before you begin, please read these instructions and check to be sure all parts
More informationDirect-operated 2/2-way solenoid valves Type EV210B
Data sheet Direct-operated 2/2-way solenoid valves Type EV20B EV20B covers a wide range of direct-operated 2/2-way solenoid valves for universal use. EV20B is a very robust valve program with high performance
More informationGMVC8. ComfortNet -Compatible. Heating Input: 70, ,000 BTU/h. Two-Stage, Variable-Speed Gas Furnace
80% AFUE Heating Input: 70,000 115,000 BTU/h ComfortNet -Compatible Two-Stage, Variable-Speed Gas Furnace Standard Features Aluminized steel, dual-diameter tubular heat exchanger Two-stage gas valve operates
More informationOEM Silicon Pressure Die
OEM Silicon Pressure Die SM9520 Series FEATURES High volume, cost effective Gauge configuration Constant current or constant voltage drive Millivolt output Available in 0.15, 0.60 & 1.50 PSIG full-scale
More informationLatest generation testo air velocity & IAQ probes with cable handle. Instruction manual
Latest generation testo air velocity & IAQ probes with cable handle Instruction manual Contents Contents 1 About this document... 5 2 Safety and disposal... 5 3 System description... 6 4 Description of
More informationPUSH TUBE STANDARD DUTY
PUSH TUBE STANDARD DUTY ASSEMBLY / OWNER S MANUAL Part No: 15-0070 PUR223 Rev. 00 OPERATING INSTRUCTIONS Congratulations! You ve just purchased the most durable plow component in the industry. Cycle Country
More informationPRECISION MAKES THE DIFFERENCE
PRECISION MAKES THE DIFFERENCE Scopes of the Police Marksman Line Schmidt & Bender Scopes of the PM Line Scopes of the Schmidt & Bender PM line have been developed in close cooperation with special forces
More informationSize A DIN EN
Size A DIN EN 70-0 Actuators 0 series DIN EN 70-0 +, + ow and high housing Degree of protection IP6 Wired versions Moulded versions Degree of protection IP67 Contacts Thread Cable outlet Ordering-No. Female
More informationOperating instructions Magnetic-inductive flow meter. SM6x01 SM7x01 SM8x / / 2015
Operating instructions Magnetic-inductive flow meter UK SM6x01 SM7x01 SM8x01 80223585 / 00 01 / 2015 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...4
More informationDirect-operated 2/2-way compact solenoid valves Type EV210A
Data sheet Direct-operated 2/2-way compact solenoid valves Type EV210A EV210A covers a wide range of small, directoperated 2/2-way solenoid valves for use in industrial machinery. The compact design together
More informationSelf-Testing Prevectron 2 Millenium Lightning Conductor Set-up and Installation Manual
Self testing Prevectron 2 Millenium Lightning Conductor ENGLISH Self-Testing Prevectron 2 Millenium Lightning Conductor Set-up and Installation Manual S6.60T S4.50T S3.40T N.B. : Information and Specifications
More informationVDN2.. VEN2.. VUN2.. Radiator valves. Building Technologies HVAC Products ACVATIX TM. NF norm, for 2-pipe heating systems
06 EN - Straight valves VDN.. Angle valves VEN.. Reverse angle valves VUN.. ACVATIX TM Radiator valves NF norm, for -pipe heating systems VDN.. VEN.. VUN.. Valve bodies made of brass, mat nickel-plated
More informationModel DS1200-AMT-Ex Intrinsically Safe 4-20mA ATEX Certified Dewpoint Hygrometer Ranges available between -120 C to +20 C (-166 F to +68 F) dewpoint
Model DS1200-AMT-Ex Intrinsically Safe 4-20mA ATEX Certified Dewpoint Hygrometer Ranges available between -120 C to +20 C (-166 F to +68 F) dewpoint Model DS1200-AMT-Ex Dewpoint Hygrometer has been designed
More informationSight Glass and Moisture Indicator Virginia KMP Series LDE
Sight Glass and Moisture Indicator Virginia KMP LDE DIMENSIONS: Dimension Dimension Connection Type "A" "B" Inches (mm) Inches (mm) LDE2 1/4 Male X 1/4 Male 2-7/8 72 1-7/ 36 LDE2S 1/4 Sweat X 1/4 Sweat
More informationBTE5000 / PTE5000 / PTU5000 Series Precision differential pressure transmitters
FEATURES 5 mbar to 0 bar, 0. to 50 psi differential pressure...6 or...0 ma Precision temperature compensated and calibrated Rugged aluminium housing Female /8" BSP and /8" NPT fittings MEDIA COMPATIBILITY
More informationConnector~Tech Providing Harsh Environment Connector
Connector~Tech www.connectortech.com.au Providing Harsh Environment Connector SOLUTIONS Tajimi TC18 series connectors are water-pro up to 30 meters in depth. Economical and highly reliable construction
More informationProximity Sensor Ideal for High Temperatures and Cleaning Processes. Applicable to 120 C
ASH & ALAIN INDIA PVT LTD S-00, F.I.E.E., Okhla Industrial Area, Phase-ii, New Delhi-000(India) Tel : 0-797575 Fax : 0-79757 E-mail : sales@ashalain.com Proximity Ideal for High Temperatures and Cleaning
More informationS TRUCTUR A L PR E- A N A LYSIS TA B LES
M a d e f o r b u i l d i n g b u i l t f o r l i v i n g S TRUTUR A L PR E- A N A LYSIS TA LES I M P R I N T KLH Massivholz GmbH Publisher and responsible for the content: KLH Massivholz GmbH Version:
More information16 Appendix 16 Electrical Research Association Report
Guide to the Wiring Regulations 16 Appendix 16 Electrical Research Association Report (ERA) report on armoured cables with external CPCs The attached report was commissioned by the ECA and is copyright
More informationPN LINE. PN Line. PX Line. PA Line. PU Line PX LINE. PV Line PA LINE & TUBINGS PU LINE PV LINE. Brass Push-in fittings
I NDEX PV LINE PX LINE PU LINE PA LINE & TUBINGS PN LINE Brass Push-in fittings Stainless Steel Push-in fittings Brass Standard fittings and Flexible Hoses Couplings and Multiple Connectors Function fittings
More informationSolenoid valves 2/2-way direct-operated type EV210A
MAKING MODERN LIVING POSSIBLE Data sheet Solenoid valves 2/2-way direct-operated type EV210A EV210A covers a wide range of small, direct-operated 2/2-way solenoid valves for use in industrial machinery.
More informationOcean Optics Red Tide UV-VIS Spectrometer (Order Code: SPRT-UV-VIS)
Ocean Optics Red Tide UV-VIS Spectrometer (Order Code: SPRT-UV-VIS) The UV-VIS spectrometer is a portable ultraviolet light and visible light spectrophotometer, combining a spectrometer and a light source/cuvette
More informationOEM Flow sensor type 235 for liquid media
OEM Flow sensor type 235 for liquid media Flow range 0.9... 240 l/min Nominal diameters DN 8 / 10 / 15 / 20 / 25 / 32 Temperature measurement -40... +125 ÀC The type 235 is based on the type 200 but incorporates
More informationMonitoring the world around us since Rainfall Measurement
Monitoring the world around Rainfall Measurement R W Munro Limited Monitoring the World Around us Since 1864 The Founder Robert William Munro, F.R.Met.Soc. 1839-1912 Established in 1864, R W Munro has
More informationM/60210/M Miniature rotary actuators
M/6020/M Miniature rotary actuators Double acting - Magnetic piston - Ø 2 and 20 mm Smooth operation with zero backlash Lightweight ompact envelope dimensions Integral magnets for positional feedback TEHNIL
More informationATV WP2 FRONT MOUNT PUSH TUBE
ATV WP2 FRONT MOUNT PUSH TUBE ASSEMBLY / OWNER S MANUAL Part No: 16-0000 MAN0352 Rev. 00 OPERATING INSTRUCTIONS Congratulations! You ve just purchased the most durable plow component in the industry. Cycle
More informationPrüf-, Überwachungs- und Zertifizierungsgemeinschaft
rüf-, berwachungs- und ertifizierungsgemeinschaft Construction roducts Regulation Berlin, 17 th July 2015 Test Certificate No. 0913-2015-02 regarding the suitability of the RetroTek-M Mobile avement Retroreflectometer
More informationFOR CAN-AM ATV s P/N ASSEMBLY / OWNERS MANUAL
MID-MOUNT KIT FOR CAN-AM ATV s P/N 15-7580 ASSEMBLY / OWNERS MANUAL Application PLOW PUSH FRAME NO. 15-0070, 33-0000 or 33-0070 Before you begin, please read these instructions and check to be sure all
More informationall stainless steel transducer multimedia compatibility
all stainless steel transducer multimedia compatibility High-Performance Silicon technology LARGE INVENTORY Fast Shipment! 0-0.07 to 0-690 bar 100 mv, 0 to 5 V, and 4 to 20 ma Outputs U 1, 2 & 5 psi Low
More informationCheck-Q-meter. Table of contents. Features. Functions. RE 27551/ /10 Replaces: Type FD
Check-Q-meter RE /0.0 /0 Replaces: 09.9 Type FD Nominal size... Series ax. Operating pressure 0 bar ax. Flow 0 l/min K9/ Table of contents Contents Page Features Functions Ordering details Symbols Functional
More informationChloramine (Mono) and Nitrogen, Free Ammonia
Chloramine (Mono) and Nitrogen, Free Ammonia DOC316.53.01016 Indophenol Method 1 Method 10200 0.04 to 4.50 mg/l Cl 2 0.01 to 0.50 mg/l NH 3 N Powder Pillows Scope and application: For the determination
More informationICE MANTLE MAKER MODEL 452 User Maintenance Manual/Handbook
ICE MANTLE MAKER MODEL 452 User Maintenance Manual/Handbook Isothermal Technology Limited, Pine Grove, Southport, PR9 9AG, England Tel: +44 (0)1704 543830 Fax: +44 (0)1704 544799 Internet: www.isotech.co.uk
More informationTemperature control for Varian Cary line of UV/Vis Spectrophotometers and the Eclipse Fluorometer
Temperature control for Varian Cary line of UV/Vis Spectrophotometers and the Eclipse Fluorometer Temperature Control without Compromise: rapid changes, precise temperatures, powerful complex functionality.
More information1073 Series One Way Snowplow owner s manual. Read before operating. Important safety and operation instructions inside.
1073 ONE WAY 1073 Series One Way Snowplow owner s manual. Read before operating. Important safety and operation instructions inside. CRAIG MANUFACTURING LTD. 96 McLean Ave. Hartland, New Brunswick CANADA
More informationROMEO ROMEO4 1x20mm COMPACT RED DOT SIGHT
ELECTRO-OPTICS ROME04T shown ROMEO ROMEO4 1x20mm COMPACT RED DOT SIGHT OWNERS MANUAL TABLE OF CONTENTS Introduction...3 Contents...4 Key Features...5 Configurations...6 Product Identification...8 Operation...9
More informationKrantz Components. Twist outlet DD-N... for ceiling installation. Air distribution systems
Krantz Components Twist outlet DD-N... for ceiling installation Air distribution systems DS E 0. Twist outlet Preliminary remarks and construction design Preliminary remarks Twist outlets for ceiling installation
More informationTeaching the Teachers
Teaching the Teachers (Safe demonstrations of chemical reactions) By Dr Colin Chambers Stimulate a teacher today and you stimulate one hundred children tomorrow Editor s note: Dr Chambers is the Chief
More informationPELICAN Ceiling. Square ceiling air diffuser for supply air and extract air QUICK FACTS
Square ceiling air diffuser for supply air and extract air QUICK FACTS Flexible distribution pattern, yet the acoustic data remains the same One K-factor regardless of distribution pattern Designed for
More informationM O D U L E - 3A Model A10V0 Piston Pump Manual A10V0 PUMP. Features
T E C H N I C A L I N F O R M A T I O N M A N U A L F O R T H E A 1 0 V 0 V A R I A B L E D I S P L A C E M E N T P U M P S A10V0 PUMP Features High Efficiency through load sensing (= fuel savings) Maximum
More informationProtective Coatings: Non-lead orange paint RAL red (optional) non-lead paint Hot dipped galvanized conforming to ASTM A-153.
Technical Services: Tel: (66) 500-76 / Fax: (01) 71-7317 www.grinnell.com Grinnell Mechanical Products Grooved Fittings, Ductile Iron & Fabricated Steel General Description Grooved fittings provide an
More informationEdition 3 September Air Angle Wrench and Nut Runner. QA6 and QA8 Series. Parts Information. Save These Instructions
660072 Edition 3 September 2007 Air Angle Wrench and Nut Runner QA6 and QA8 Series Parts Information Save These Instructions Module Exploded Diagram 7 5 9 7 2 9 50 3 8 3 38 39 8 9 20 2 33 22 23 3 2 3 37
More informationINDEX OF ILLUSTRATIONS
INDEX OF ILLUSTRATIONS FIG 3.1.1 FIG 3.1.2 FIG 3.1.3 FIG 3.2.1 FIG 3.2.2 FIG 3.2.3 FIG 3.2.4 FIG 3.3.1 FIG 3.4.1 FIG 3.4.1.1 ENVELOPE TYPES ENVELOPE NOMENCLATURE OVERVIEW VELCRO RIP & Q-VENT BASKET NOMENCLATURE
More informationOperating instructions Magnetic-inductive flow sensor SM6004 SM7004 SM / / 2014
Operating instructions Magnetic-inductive flow sensor SM6004 SM7004 SM8004 80003223 / 00 05 / 2014 Contents 1 Preliminary note...3 1.1 Symbols used...3 2 Safety instructions...4 3 Functions and features...5
More informationR a t i o n a l i s e d B r a k e A c t u a t o r s
C o m m e r c i a l V e h i c l e S y s t e m s P r o d u c t C a t a l o g u e R a t i o n a l i s e d B r a k e A c t u a t o r s... for Air Disc Brake applications Disclaimer The information contained
More informationSCREEN LOW E SATINÉ 5500 LOW E
SCREEN LOW E SATINÉ 5500 LOW E SCREEN LOW E INTELLIGENT FABRICS FOR SOLAR PROTECTION COLLECTION 2018 2021 INTERNAL APPLICATION www.sunscreen-mermet.com THERMAL SHIELD FOR INTERNAL BLINDS 78% OF SOLAR REFLECTANCE
More informationDewpoint Meter Data Sheet / Instructions
Paint Test Equipment Dewpoint Meter Data Sheet / Instructions Dewpoint Meter Information ISO 8502-4: Preparation of steel substrates before application of paints and related products. Tests for the assessment
More informationMercuric Thiocyanate Method Method to 25.0 mg/l Cl Reagent Solution
Chloride DOC316.53.01017 Mercuric Thiocyanate Method Method 8113 0.1 to 25.0 mg/l Cl Reagent Solution Scope and application: For water and wastewater. Test preparation Instrument-specific information Table
More informationSCREEN LOW E SATINÉ 5500 LOW E
SCREEN LOW E SATINÉ 5500 LOW E SCREEN LOW E SATINÉ 5500 LOW E INTELLIGENT FABRICS FOR SOLAR PROTECTION COLLECTION 2018 2021 INTERNAL APPLICATION www.sunscreen-mermet.com SATINÉ 5500 LOW E THERMAL SHIELD
More informationCRAIG MANUFACTURING LTD. 96 McLean Ave. Hartland, New Brunswick CANADA E7P 2K5
SNOWPLOW 0600 0600 Series Hydraulic Reversible Snowplow owner s manual. Read before operating. Important safety and operation instructions inside. CRAIG MANUFACTURING LTD. 96 McLean Ave. Hartland, New
More information7300 TERMINAL DESIGN BY KUSCH+CO DESIGNTEAM, EICHINGER & LOIDOLT
7300 TERMINAL DESIGN BY KUSCH+CO DESIGNTEAM, EICHINGER & LOIDOLT T h i s s e r i e s c o m e s i n m a n y v a r i a t i o n s, o p e n i n g u p a w h o l e g a m u t o f v a r i e d c o n f i g u r a
More informationHARTING D-Sub Selection Guide
HARTING D-Sub Selection Guide People Power Partnership D-Sub Selection Guide D-Sub Device Connectivity HARTING Connectivity & Networks generates solutions throughout the triad of Installation Technology,
More informationSECTION 5 EDI Cartridge Valves
SECTION Cartridge Valves Make Model Page Way Pilot Operated Poppet Style Way Pilot Operated Double Lock Way Direct cting 3 Way -Position Direct cting 4 Way -Position Direct cting Spool Style 4 Way 3-Position
More information