DCG Commercial. 7½ - 12½ Ton Packaged Gas/ Electric Up to 11.3 EER / 80% AFUE

Size: px
Start display at page:

Download "DCG Commercial. 7½ - 12½ Ton Packaged Gas/ Electric Up to 11.3 EER / 80% AFUE"

Transcription

1 DG ommercial ½ - ½ Ton Packaged Gas/ Electric Up to. EER / 0% AUE ooling apacity:,000,000 BTU/h Heating apacity (Output):,000 BTU/h ontents Nomenclature... Product Specifications... Expanded ooling Data... Airflow Data... rankcase Heater... 0 Dimensions... Wiring Diagrams... for Models with DD ontrols... Accessories... Standard eatures TuffTube tubular heat exchanger High-efficiency scroll compressors Two-stage heating and cooling opper tube / aluminum fin coils Power block for field wiring High-capacity, steel-cased filter drier Single-point entry -volt terminal strip onvertible airflow orientation Built-in filter rack with standard " filters omplies with alifornia Low NOx emissions standards Units meet the performance outlined in Table..A of ASHRAE Standard AHRI ertified; ETL Listed abinet eatures Heavy-gauge, galvanized-steel cabinet with UV-resistant powder-paint finish ull perimeter rail Sloped drain pan Easy to service * omplete warranty details available from your local dealer or at SS-DG /B Supersedes /A

2 Nomenclature D G 0 0 B * * * A *,,,, 0 Revision Levels Major & Minor Brand actory-installed Options D Daikin X No Options A Non-powered convenience outlet onfiguration B Powered convenience outlet Standard Efficiency ( - Tons) Low-ambient kit S Standard Efficiency ( - Tons) D Return air smoke detector T High Efficiency ( - Tons) E Supply air smoke detector Non-powered convenience outlet; Application Low-ambient kit ooling G Non-powered convenience outlet; G Gas Heat Return air smoke detector H Heat Pump H Non-powered convenience outlet; Supply air smoke detector Nominal ooling apacity J Non-powered convenience outlet; 0 Tons 0 ½ Tons 00 Tons Return & Supply air smoke detectors 0 Tons 0 0 Tons K Non-powered convenience outlet; 00 Tons 0 ½ tons Low-ambient kit; Supply air smoke detector 0 Tons 0 Tons L Non-powered convenience outlet; 00 ½ Tons 0 0 Tons Low-ambient kit Return & Supply air smoke detectors Nominal Heating apacity M Powered convenience outlet; Gas/Electric A/ H/P actory-installed Electric Heat Low-ambient kit 0,000 BTU/h XXX No Heat N Powered convenience outlet; 00 0,000 BTU/h 00 0 kw 00 0 kw Return air smoke detector,000 BTU/h 0 kw 0 0 kw O Powered convenience outlet; 0 0,000 BTU/h 0 kw 0 kw Return & Supply air smoke detectors 0 0,000 BTU/h 0 kw 0 kw P Powered convenience outlet; 0 0,000 BTU/h 00 0 kw 00 0 kw Supply air smoke detector 00 00,000 BTU/h 0 kw Q Powered convenience outlet; Low-ambient See product specifications for heat size(s) available for each capacity. kit; Return air smoke detector R Powered convenience outlet; Low-ambient Voltage kit; Supply air smoke detector 0-0//0 0//0 T Powered convenience outlet; Low-ambient 0-0//0 //0 kit; Return & Supply air smoke detectors U Non-powered convenience outlet; Supply an/drive Type/Motor Low-ambient kit; Return air smoke detector B Belt Drive (single speed) V Two-Speed Belt Drive (also designates -Ton V Low-ambient kit; Return air smoke detector D Direct Drive (- Tons) with two-stage compressor) W Low-ambient kit; Supply air smoke detector H High Static (Single-Speed models) Y Low-ambient kit; Return & Supply actory-installed Options air smoke detectors A Ultra Low-Leak Downflow Economizer R Ultra Low-Leak Downflow Economizer ; Z Return & Supply air smoke detectors B DD-BAnet protocol DD-BAnet protocol; Ultra Low-Leak Downflow Economizer ; Disconnect Switch (non-fused) DD-BAnet protocol V Low-Leak Downflow Economizer actory-installed Options H Disconnect Switch (non-fused) W Low-Leak Downflow Economizer X Standard Aluminized Heat Exchanger J Ultra Low-Leak Downflow Economizer ; Disconnect Switch (non-fused) S Stainless-Steel Heat Exchanger Disconnect Switch (non-fused) X No Options D Hinged Panels M Disconnect Switch (non-fused); DD-BAnet protocol K Stainless-Steel Heat Exchanger; Hinged Panels Note: Not all options available for all products. B Phase Monitor Please contact RRS Rooftop Systems directly if Power Exhaust is required. Ultra Low-Leak economizer for DD controls. J Stainless Steel Heat Exchanger; Phase Monitor Please use part number DPE / DPE / DPE if Power Exhaust is required. M Hinged Panel; Phase Monitor X= No Options in character th L Stainless-Steel Heat Exchanger; Hinged Panels; Phase Monitor SS-DG

3 Nomenclature actory-installed Options Stainless-Steel Heat Exchanger (Gas units only): A tubular heat exchanger made of 0-type stainless steel is installed in the unit. Low-Ambient Kit: Allows for cooling operation at lower outdoor temperatures. On the - to -ton units, cooling operation is extended from 0 ambient temperature to outside air temperature. On ½ -0 ton units, cooling operation is extended from ambient temperature to 0 outside air temperature. or ton units, cooling operation is extended from ambient temperature to 0 outside air temperature. Economizers (Downflow): Based on air conditions, can provide outside air to cool the space. Electric Heat Kits (A and heat pump units only): Available in all voltage options. Non-powered onvenience Outlet: A 0V, A, GI outlet makes it easier for technicians to service the unit once an electrician runs power to the outlet. Powered onvenience Outlet: A 0V, A, GI outlet powered with a transformer built into the unit. When a factory-installed powered convenience outlet is installed in the equipment, the unit MA (Min. ircuit Ampacity) will increase by.a for 0/0V units, increase by.a for 0V units, and by A for V units. The MOP (Max. Overcurrent Protection) device must be sized accordingly. Disconnect Switch (non-fused; -phase units only): A disconnect switch is installed in the unit and factory wiring will be complete from the switch to the unit. Please note that for air conditioning (DS units) and heat pump models (DSH units), the appropriate electric heat kit must be ordered to be factory-installed along with the disconnect switch (non-fused) when it is ordered. Please note that for models with a powered convenience outlet option and a disconnect switch (non-fused) option, the power to the powered convenience outlet will be shut off when the disconnect switch (non-fused) is in the off position. Return Air and/or Supply Air Smoke Detectors: Return air and/or supply air smoke detectors are installed in the unit. Hinged Access Panels: Allows access to unit s major components. ombined with latches for easy access to control box, compressor, filters and blower motor. Available on all units. Two-speed indoor fan blower models are available on, ½, ½, 0, ½,, 0 & ton units. Section...0.b of ASHRAE Standard and Section...a of ASHRAE Standard 0.-0 require a minimum of two fan speeds. Section 0.(m) of alifornia Energy ommission Title 0 contains a similar provision. When the units with the two-speed indoor fan blowers operate on a call for the first stage of cooling, the fan operates at low speed, which is % of full speed. When the units operate on a call for the second stage of cooling, the fan operates at full speed. In heating operation, the fan operates at full speed. During ventilation operation, the fan operates at low speed. Phase Monitor: Phase monitor ( phase only), available for - ton DS, D and DT series models. Phase monitor shall provide protection for motors and compressors against problems caused by phase loss, phase reversal and phase unbalance. Phase monitor is equipped with an LED that provides an ON or AULT indicator. DD ontroller: DD communicating controller, available for - ton DS, D and DT series models with on-board BAnet communication interface. SS-DG

4 Product Specifications ½ Tons DG00 0B*** A* DG00 0V*** A* DG00 0B***A* DG00 0V*** A* DG00 0B*** A* DG00 0V*** A* ooling apacity Total BTU/h,000,000,000,000,000,000 Sensible BTU/h,00,00,00,00,00,00 EER / IEER. /.. /.0. /.. /.0. /.. /.0 Decibels AHRI Reference #s Heating apacity High Input / Output BTU/h 0,000/,000 0,000/,000 0,000/,000 0,000/,000 0,000/,000 0,000/,000 Low Input / Output BTU/h,00/,000,00/,000,00/,000,00/,000,00/,000,00/,000 Steady-State Efficiency (AUE) Temperature Rise Range ( ) No. of Burners Evaporator Motor / oil Motor Type Belt Drive -speed Belt Drive Belt Drive -speed Belt Drive Belt Drive -speed Belt Drive Indoor Nominal M,000,000,000,000,000,000 LA (ooling) Horsepower / RPM ½ / / 0-0 ½ / / 0-0 ½ / / -0 Piston Size (ooling) ilter Size (Qty) () " x 0" x " () x 0 x () x 0 x () x 0 x () x 0 x () x 0 x Drain Size (NPT) ¾" ¾" ¾" ¾" ¾" ¾" R-0A Refrigerant harge: ir # / # 00 oz. 00 oz. 00 oz. 00 oz. 00 oz. 00 oz. Evaporator oil ace Area (ft²) Rows Deep / ins per Inch / / / / / / Belt Drive Evap an Data # of Wheels (D x W) (" x ") (" x ") (" x ") (" x ") (" x ") (" x ") Motor / Blower Sheave VL0 / AK VL0 / AK VL0 / AK VL0 / AK VL0 / AK VL0 / AK Belt AX AX AX AX AX AX ondenser an / oil Quantity of ondenser an Motors Horsepower - RPM ¼ - 0 ¼ - 0 ¼ - 0 ¼ - 0 ¼ - 0 ¼ - 0 an Diameter / # an Blades / / / / / / Outdoor Nominal M,00,00,00,00,00,00 ace Area (ft²) Rows Deep / ins per Inch X / ± X / ± ' X / ± ' X / ± ' X / ± ' X / ± ompressor Quantity / Type / Stage / Scroll / / Scroll / / Scroll / / Scroll / / Scroll / / Scroll / ompressor RLA / LRA. /.. /.. /.0. /.0. /.0. /.0 Electrical Data Voltage / Phase 0-0 / 0-0 / 0 / 0 / / / Indoor Blower HP / LA. /.0 /.0. /. /.. /. /. Standard Motor Max. External Static.0".0".0".0".0".0" Outdoor an HP / RLA () ¼ /. () ¼ /. () ¼ / 0. () ¼ / 0. () ¼ / 0. () ¼ / 0. Total Unit Amps Min. ircuit Ampacity¹.... Max. Overcurrent Protection (amps)² Entrance Power Supply Locating Locating Locating Locating Locating Locating Entrance ontrol Voltage Dimple Dimple Dimple Dimple Dimple Dimple Operating Weight (lbs) Ship Weight (lbs) ¹ Wire size should be determined in accordance with National Electrical odes. Extensive wire runs will require larger wire sizes. ² May use fuses or HAR-type circuit breakers of the same size as noted. Note: Always check the S&R plate for electrical data on the unit being installed. SS-DG

5 Product Specifications ½ Tons DG0 0B***A* DG0 0V***A* DG0 0B***A* DG0 0V***A* DG0 0B***A* DG0 0V***A* ooling apacity Total, BTU/h 0,000 0,000 0,000 0,000 0,000 0,000 Sensible BTU/h 0,0 0,0 0,0 0,0 0,0 0,0 EER / IEER. /.. /.. /.. /.. /.. /. Decibels ARI Reference #s Heating apacity High Input / Output BTU/h 0,000/,000 0,000/,000 0,000/,000 0,000/,000 0,000/,000 0,000/,000 Low Input / Output BTU/h,00/,000,00/,000,00/,000,00/,000,00/,000,00/,000 Steady State Efficciency Temperature Rise Range ( ) No. of Burners Evaporator Motor / oil Motor Type Belt Drive -speed Belt Drive Belt Drive -speed Belt Drive Belt Drive -speed Belt Drive Indoor Nominal M,00,00,00,00,00,00 Indoor Motor LA (ooling) Horsepower - RPM / / 0-0 / / 0-0 / / -0 Piston Size (ooling) ilter Size (Qty) () x x () x x () x x () x x () x x () x x Drain Size (NPT) /" /" /" /" /" /" R-0A Refrigerant harge ir # # (oz.) Evaporator oil ace Area (ft) Rows Deep / ins per Inch / / / / / / Belt Drive Evap an Data # of Wheels (D x W) (" x ") (" x ") (" x ") (" x ") (" x ") (" x ") Motor Sheave / Blower Sheave VL0 / AK VL0 / AK VL0 / AK VL0 / AK VL0 / AK VL0 / AK Belt AX AX AX AX AX AX ondenser an / oil Quantity of ondenser an Motors Horsepower - RPM ⅓ -,0 ⅓ -,0 ⅓ -,0 ⅓ -,0 ⅓ -,0 ⅓ -,0 an Diameter / # an Blades / / / / / / Outdoor Nominal M,00,00,00,00,00,00 ace Area (ft²) Rows Deep / ins per Inch ' X / ± ' X / ± ' X / ± ' X / ± ' X / ± ' X / ± ompressor Quantity / Type / Stage / Scroll / / Scroll / / Scroll / / Scroll / / Scroll / / Scroll / ompressor RLA / LRA ea.. /. /. /. /.0 /.0 / Electrical Data / Static Voltage / Phase (0 Hz) 0-0 / 0-0 / 0 / 0 / / / Outdoor an LA ea Standard Motor Max. External Static.0".0".0".0".0".0" Total Unit Amps Min. ircuit Ampacity¹ Max. Overcurrent Protection (amps)² Entrance Power Supply Locating Locating Locating Locating Locating Locating Entrance ontrol Voltage Dimple Dimple Dimple Dimple Dimple Dimple Operating Weight (lbs) Ship Weight (lbs) ¹ Wire size should be determined in accordance with National Electrical odes. Extensive wire runs will require larger wire sizes. ² May use fuses or HAR-type circuit breakers of the same size as noted. Note: Always check the S&R plate for electrical data on the unit being installed. SS-DG

6 Product Specifications 0 Tons DG0 0B***A* DG0 0V***A* DG0 0B***A* DG0 0V***A* DG0 0B***A* DG0 0V***A* ooling apacity Total BTU/h,000,000,000,000,000,000 Sensible BTU/h,00,00,00,00,00,00 EER / IEER. /.. /.. /.. /.. /.. /. Decibels ARI Reference #s Heating apacity High Input/Output (BTU/h) 0,000/ 0,000/ 0,000/ 0,000/ 0,000/ 0,000/,000,000,000,000,000,000 Low Input/Output (BTU/h),00/,00/,00/,00/,00/,00/,000,000,000,000,000,000 Steady State Efficiency Temperature Rise Range ( ) No. of Burners Evaporator Motor / oil Motor Type Belt Drive -speed Belt Drive Belt Drive -speed Belt Drive Belt Drive -speed Belt Drive Indoor Nominal M,00,00,00,00,00,00 Indoor Motor LA (ooling) Horsepower - RPM.0 -,.0/0-.0 -,.0/0-.0 -,.0/0- Piston Size (ooling) ilter Size (Qty) () x x () x x () x x () x x () x x () x x Drain Size (NPT) ¾" ¾" ¾" ¾" ¾" ¾" R-0A Refrigerant harge ir # & (oz.) / / / / / / Evaporator oil ace Area (ft²) Rows Deep/ ins per Inch / / / / / / Belt Drive Evap an Data # of Wheels (D x W) () x () x () x () x () x () x Motor Sheave / Blower Sheave VL0 / AK VL0 / AK VL0 / AK VL0 / AK VL0 / AK VL0 / AK Belt AX AX0 AX AX0 AX AX0 ondenser an / oil Quantity of ondenser an Motors Horsepower - RPM ⅓ -,0 ⅓ -,0 ⅓ -,0 ⅓ -,0 ⅓ -,0 ⅓ -,0 an Diameter / # an Blades / / / / / / Outdoor Nominal M,00,00,00,00,00,00 ace Area (ft²) # oils / Rows Deep - ins per Inch X / ± X / ± X / ± X / ± X / ± X / ± ompressor Quantity / Type / Stage / Scroll / / Scroll / / Scroll / / Scroll / / Scroll / / Scroll / ompressor RLA / LRA ea. / 0.0 / 0.0. /.0. /.0. /.. /. Electrical Data Voltage/Phase/ requency 0-0/ / 0 0-0/ / 0 0/ / 0 0/ / 0 / / 0 / / 0 Outdoor an RLA ea Standard Motor Max. External Static Total Unit Amps Min. ircuit Ampacity¹ Max. Overcurrent Protection (amps)² Entrance Power Supply Locating Locating Locating Locating Locating Locating Entrance ontrol Voltage Dimple Dimple Dimple Dimple Dimple Dimple Operating Weight (lbs) Ship Weight (lbs) ¹ Wire size should be determined in accordance with National Electrical odes. Extensive wire runs will require larger wire sizes. ² May use fuses or HAR-type circuit breakers of the same size as noted. Note: Always check the S&R plate for electrical data on the unit being installed. SS-DG

7 Product Specifications ½ Tons DG0 0B***A* DG0 0V***A* DG0 0B***A* DG0 0V***A* DG0 0B***A* DG0 0V***A* ooling apacity Total, BTU/h,000,000,000,000,000,000 Sensible BTU/h 00,000 00,000 00,000 00,000 00,000 00,000 EER / IEER 0. /.0 0. /.0 0. /.0 0. /.0 0. /.0 0. /.0 Decibels ARI Reference #s Heating apacity High Input / Output BTU/h 0,000 /,000 0,000 /,000 0,000 /,000 Low Input / Output BTU/h,00 /,000,00 /,000,00 /,000 Steady State Efficiency Temperature Rise Range ( ) No. of Burners Evapoartor Motor / oil Motor Type (Belt Drive) Belt Drive -speed Belt Drive Belt Drive -speed Belt Drive Belt Drive -speed Belt Drive Indoor Nominal M,00,00,00,00,00,00 Indoor Motor LA (ooling) Horsepower - RPM.0 -,.0/0-.0 -,.0/0-.0 -,.0/0- Piston Size (ooling) ilter Size (Qty) () 0" x " x " () 0" x " x " () 0" x " x " () 0" x " x " () 0" x " x " () 0" x " x " Drain Size (NPT) ¾" ¾" ¾" ¾" ¾" ¾" R-0A Refrigerant harge ir #/ # (oz.) Evaporator oil ace Area (ft ) Rows Deep / ins per Inch / / / / / / Belt Drive Evap an Data # of Wheels (D x W) () " x " () " x " () " x " () " x " () " x " () " x " Motor Sheave / Blower Sheave VL0 / AK VP / AK VL0 / AK VP / AK VL0 / AK VP / AK Belt AX AX AX AX AX AX ondenser an / oil Quantity of condenser an Motors Horsepower - RPM ⅓ -,0 ⅓ -,0 ⅓ -,0 ⅓ -,0 ⅓ -,0 ⅓ -,0 an Diameter / # an Blades / / / / / / Outdoor Nominal M,00,00,00,00,00,00 ace Area (ft ) # oils / Rows Deep - ins per Inch / rows fpi / rows fpi / rows fpi / rows fpi / rows fpi / rows fpi ompressor Quantity / Type / Stage / Scroll / / Scroll / / Scroll / / Scroll / / Scroll / / Scroll / ompressor RLA / LRA ea.. /. / 0. / 0. /. /. / Electrical Data / Static Voltage / Phase / requency 0-0//0 0-0//0 0//0 0//0 //0 //0 Standard Motor Max. External Static."."."."."." Outdoor an LA ea Total Unit Amps Min. ircuit Ampacity.. Max. Overcurrent Protection (amps) Entrance Power Supply Locating Locating Locating Locating Locating Locating Entrance ontrol Voltage Dimple Dimple Dimple Dimple Dimple Dimple Operating Weight (lbs) Ship Weight (lbs) ¹ Wire size should be determined in accordance with National Electrical odes. Extensive wire runs will require larger wire sizes. ² May use fuses or HAR-type circuit breakers of the same size as noted. Note: Always check the S&R plate for electrical data on the unit being installed. SS-DG

8 Expanded ooling Data ½ Tons Outdoor Ambient Temperature 0 Entering Indoor Wet Bulb Temperature IDB Airflow MBh S/T T kw Hi PR Lo PR MBh S/T T kw Hi PR Lo PR MBh S/T T kw Hi PR Lo PR MBh S/T T kw Hi PR Lo PR 0 0 MBh S/T T kw Hi PR Lo PR 0 MBh 0 S/T T kw Hi PR Lo PR IDB: Entering Indoor Dry Bulb Temperature Shaded area reflects AA (TVA) Rating onditions Amps: Unit amps (comp.+ evaporator + condenser fan motors) High and low pressures are measured at the liquid and suction access fittings. Design Superheat ±, Design Subcooling ± pressures the suction and liquid service ports, AHRI test conditions SS-DG

9 Expanded ooling Data ½ Tons (cont.) Outdoor Ambient Temperature 0 Entering Indoor Wet Bulb Temperature IDB Airflow MBh S/T T kw Hi PR Lo PR MBh 0 0 S/T T kw Hi PR Lo PR 0 0 MBh 0 0. S/T T kw Hi PR Lo PR MBh S/T T kw Hi PR Lo PR 0 0 MBh S/T T kw Hi PR Lo PR MBh. S/T T kw Hi PR Lo PR IDB: Entering Indoor Dry Bulb Temperature Shaded area reflects AHRI Rating onditions Amps: Unit amps (comp.+ evaporator + condenser fan motors) High and low pressures are measured at the liquid and suction access fittings. Design Superheat ±, Design Subcooling ± pressures the suction and liquid service ports, AHRI test conditions SS-DG

10 Expanded ooling Data ½ Tons Outdoor Ambient Temperature 0 Entering Indoor Wet Bulb Temperature IDB Airflow MBh S/T T kw Hi PR Lo PR MBh S/T T kw Hi PR Lo PR MBh S/T T kw Hi PR Lo PR MBh S/T T kw Hi PR Lo PR MBh S/T T kw Hi PR Lo PR MBh S/T T kw Hi PR 0 0 Lo PR IDB: Entering Indoor Dry Bulb Temperature Shaded area reflects AA (TVA) Rating onditions Amps: Unit amps (comp.+ evaporator + condenser fan motors) High and low pressures are measured at the liquid and suction access fittings. Design Subcooling, liquid access fitting; AHRI test conditions. Design Superheat compressor suction access fitting. 0 SS-DG

11 Expanded ooling Data ½ Tons (cont.) Outdoor Ambient Temperature 0 Entering Indoor Wet Bulb Temperature IDB Airflow MBh S/T T kw Hi PR Lo PR 0 MBh S/T T kw Hi PR Lo PR MBh S/T T kw Hi PR Lo PR MBh S/T T kw Hi PR Lo PR MBh S/T T kw Hi PR Lo PR 0 MBh S/T T kw Hi PR Lo PR IDB: Entering Indoor Dry Bulb Temperature Shaded areas reflect AHRI Rating onditions AM: Unit amps (comp.+ evaporator + condenser fan motors) High and low pressures are measured at the liquid and suction access fittings. Design Subcooling, liquid access fitting; AHRI test conditions. Design Superheat compressor suction access fitting. SS-DG

12 Expanded ooling Data 0 Tons Outdoor Ambient Temperature 0 Entering Indoor Wet Bulb Temperature IDB Airflow MBh S/T T kw Hi PR Lo PR MBh S/T T kw Hi PR Lo PR MBh S/T T kw Hi PR Lo PR MBh S/T T kw Hi PR Lo PR MBh S/T T kw Hi PR Lo PR MBh S/T T kw Hi PR Lo PR IDB: Entering Indoor Dry Bulb Temperature Shaded area reflects AA (TVA) Rating onditions Amps: Unit amps (comp.+ evaporator + condenser fan motors) High and low pressures are measured at the liquid and suction access fittings. Design Superheat ±, Design Subcooling ± pressures the suction and liquid service ports, AHRI test conditions SS-DG

13 Expanded ooling Data 0 Tons (cont.) Outdoor Ambient Temperature 0 Entering Indoor Wet Bulb Temperature IDB Airflow MBh S/T T kw Hi PR Lo PR MBh S/T T kw Hi PR Lo PR MBh S/T T kw Hi PR Lo PR MBh S/T T kw Hi PR Lo PR 0 0 MBh S/T T kw Hi PR Lo PR MBh S/T T kw Hi PR Lo PR IDB: Entering Indoor Dry Bulb Temperature Shaded area reflects AHRI Rating onditions Amps: Unit amps (comp.+ evaporator + condenser fan motors) High and low pressures are measured at the liquid and suction access fittings. Design Superheat ±, Design Subcooling ± pressures the suction and liquid service ports, AHRI test conditions SS-DG

14 Expanded ooling Data ½ Tons Outdoor Ambient Temperature 0 Entering Indoor Wet Bulb Temperature IDB Airflow MBh S/T T kw Hi PR Lo PR MBh S/T T kw Hi PR Lo PR MBh S/T T kw Hi PR Lo PR MBh S/T T kw Hi PR Lo PR MBh 0 0 S/T T kw Hi PR 0 Lo PR MBh S/T T kw Hi PR Lo PR IDB: Entering Indoor Dry Bulb Temperature Shaded area reflects AA Rating onditions Amps: Unit amps (comp.+ evaporator + condenser fan motors) High and low pressures are measured at the liquid and suction access fittings. Design Superheat ±, Design Subcooling ± pressures the suction and liquid service ports, AHRI test conditions SS-DG

15 Expanded ooling Data ½ Tons (cont.) Outdoor Ambient Temperature 0 Entering Indoor Wet Bulb Temperature IDB Airflow MBh S/T T kw Hi PR Lo PR MBh S/T T kw Hi PR Lo PR MBh S/T T kw Hi PR Lo PR MBh S/T T kw Hi PR Lo PR MBh S/T T kw Hi PR Lo PR MBh S/T T kw Hi PR Lo PR IDB: Entering Indoor Dry Bulb Temperature Shaded area reflects AHRI Rating onditions Amps: Unit amps (comp.+ evaporator + condenser fan motors) High and low pressures are measured at the liquid and suction access fittings. Design Superheat ±, Design Subcooling ± pressures the suction and liquid service ports, AHRI test conditions SS-DG

16 Airflow Data ½ Tons ESP ( W..) Standard Belt Drive & Two-Speed Standard Belt Drive at High Speed Down Shot Turns Open 0 M RPM BHP M RPM BHP M RPM BHP M RPM BHP M RPM BHP M RPM BHP ESP ( W..) High-Static Belt Drive Down Shot Turns Open 0 M RPM BHP M RPM BHP M RPM BHP M RPM BHP M RPM BHP M RPM BHP ESP ( W..) Standard Belt Drive & Two-Speed Standard Belt Drive at High Speed Horizontal Turns Open 0 M RPM BHP M RPM BHP M RPM BHP M RPM BHP M RPM BHP M RPM BHP ESP ( W..) High-Static Belt Drive Horizontal Turns Open 0 M RPM BHP M RPM BHP M RPM BHP M RPM BHP M RPM BHP M RPM BHP Notes Assume dry coil with filter in place; M correction for wet coil = % Any adjustment made to the blower should not cause the motor to draw more than the motor rated RLA. Applications that exceed the above could require a larger motor. Minimum rated SM is 0 per ton. SS-DG

17 Airflow Data ½ Tons ESP ( W..) Standard Belt Drive & Two-Speed Standard Belt Drive at High Speed Down Shot Turns Open 0 M RPM BHP M RPM BHP M RPM BHP M RPM BHP M RPM BHP M RPM BHP ESP ( W..) High-Static Belt Drive -- Down Shot Turns Open 0 M RPM BHP M RPM BHP M RPM BHP M RPM BHP M RPM BHP M RPM BHP ESP ( W..) Standard Belt Drive & Two-Speed Standard Belt Drive at High Speed Horizontal Turns Open 0 M RPM BHP M RPM BHP M RPM BHP M RPM BHP M RPM BHP M RPM BHP ESP ( W..) High-Static Belt Drive -- Horizontal Turns Open 0 M RPM BHP M RPM BHP M RPM BHP M RPM BHP M RPM BHP M RPM BHP Notes Assume dry coil with filter in place; M correction for wet coil = % Any adjustment made to the blower should not cause the motor to draw more than the motor rated RLA. Applications that exceed the above could require a larger motor. Minimum rated SM is 0 per ton. SS-DG

18 Airflow Data 0 Tons ESP ( W..) Standard & Two-Speed Belt-Drive at High Speed Down Shot Turns Open 0 M RPM BHP M RPM BHP M RPM BHP M RPM BHP M RPM BHP M RPM BHP ESP ( W..) High-Static Belt-Drive Down Shot Turns Open 0 M RPM BHP M RPM BHP M RPM BHP M RPM BHP M RPM BHP M RPM BHP ESP ( W..) Standard & Two-Speed Belt-Drive at High Speed Horizontal Turns Open 0 M RPM BHP M RPM BHP M RPM BHP M RPM BHP M RPM BHP M RPM BHP ESP ( W..) 0. High-Static Belt-Drive Horizontal Turns Open 0 M RPM BHP M RPM BHP M RPM BHP M RPM BHP M RPM BHP M RPM BHP DO NOT OPERATE Notes Assume dry coil with filter in place; M correction for wet coil = % Any adjustment made to the blower should not cause the motor to draw more than the motor rated RLA. Applications that exceed the above could require a larger motor. Minimum rated SM is 0 per ton. SS-DG

19 Airflow Data ½ Tons ESP ( W..) Standard Belt Drive and Speed Belt Drive at High Speed Down Shot Turns Open 0 M BHP M BHP M BHP M BHP M BHP M BHP ESP ( W..) High-Static Belt Drive Down Shot Turns Open 0 M BHP M BHP M BHP M BHP M BHP M BHP ESP ( W..) Standard Belt Drive and Speed Belt Drive at High Speed Horizontal Turns Open 0 M BHP M BHP M BHP M BHP M BHP M BHP ESP ( W..) High-Static Belt Drive Horizontal Turns Open 0 M BHP M BHP M BHP M BHP M BHP M BHP Notes Assume dry coil with filter in place; M correction for wet coil = % Any adjustment made to the blower should not cause the motor to draw more than the motor rated RLA. Application that exceed the above could require a larger motor. Minimum rated SM is 0 per ton. Airflow Pressure Drop of Downflow Economizer for. to. Ton Rooftop Units (00% Return Air) SM in. WG SS-DG

20 rankcase Heater, High Efficiency MERV Air ilter Option w 0.0 landers Pre Pleat M Air Velocity vs Resistance (Test Size: " x " x " High apacity) " Deep Resistance (in. w.g.) Air Velocity (PM) Tonnage: ilter Nominal Size: Part Number: QTY: x x 00L000 x 0 x 00L000,,. x 0 x 00L000.(HP),., 0 X X 00L x x 00L000, 0 0 x x 00L000 0 X 0 X 00L000 rankcase Heater Selection Table ompressor Voltage rankcase ZP/Z ompressor Diameter 0V 0V V Heater Watts -." 0R0000 0R000 0R /." 00L000 00L000 00L L L000 00L000 0 D*,DT* & DS* Tonnage ompressor Voltage 0V 0V V rankcase Heater Watts Ton 0R0000 0R000 0R000 0 Ton-. Ton 00L000 00L000 00L Ton** 00L000 00L000 00L000 0 Ton 00L L000 00L000 0 *Includes,G&H models. **If ompressor Diameter is. then use Ton rankcase heaters. 0 SS-DG

21 Dimensions TOP VIEW LUE / VENT OUTLET GAS LINE ENTRANE..0 RONT VIEW OMBINATION AIR INLET (GAS UNIT) ALL DIMENSIONS GIVEN ARE IN INHES ALL DIMENSIONS AND SPEIIATIONS ARE SUBJET TO HANGE WITHOUT NOTIE D*00-0***. THRU. TON OMMERIAL "A" MODEL TONNAGE "A" "B". TON OMMERIAL GAS, HT MP, AIR ONDITIONER TON OMMERIAL GAS, HT MP, AIR ONDITIONER TON OMMERIAL GAS, HT MP, AIR ONDITIONER TON OMMERIAL GAS, HT MP, AIR ONDITIONER..0 SUPPLY AIR DUT ONDENSATE DRAIN OUTLET DISONNET SWITH RETURN AIR SUPPLY... "B" LITING SHAKLE HOLES BOTH SIDES AND ENDS RIGHT END VIEW SS-DG

22 Unit learances Maintain an adequate clearance around the unit for safety, service, maintenance, and proper unit operation. Leave a total clearance of on the main control panel side of the unit for possible removal of fan shaft, coil, electric heat, and gas furnace. Leave a clearance of on all other sides of the unit for possible compressor removal or service access, and to ensure proper ventilation and condenser airflow. Do not install the unit beneath any obstruction. Install the unit away from all building exhausts to inhibit ingestion of exhaust air into the unit s fresh-air intake. Min. Electrical Entrance Locations ¾ / DIMPLES Dimples Mark MARK Drill Locations DRILL LOATIONS HIGH High-Voltage Entrance ENTRANE 0 0/ LOW Low-Voltage Entrance ENTRANE ½ Power and Low-Voltage Block Locations SS-DG

23 Roof urb Installation Rigging Provisions for forks have been included in the unit base frame. No other fork locations are approved. Unit must be lifted by the four lifting holes located at the base frame corners. Lifting cables should be attached to the unit with shackles. The distance between the crane hook and the top of the unit must not be less than 0. Two spreader bars must span over the unit to prevent damage to the cabinet by the lift cables. Spreader bars must be of sufficient length so that cables do not come in contact with the unit during transport. Remove wood struts mounted beneath unit base frame before setting unit on roof curb. These struts are intended to protect unit base frame from fork lift damage. To remove the struts, extract the sheet metal retainers and pull the struts through the base of the unit. Refer to rigging label on the unit. Important: If using bottom discharge with roof curb, duct-work should be attached to the curb prior to installing the unit. Duct-work dimensions are shown in Roof urb Installation Instructions Manual. Refer to the Roof urb Installation Instructions for proper curb installation. urbing must be installed in compliance with the National Roofing ontractors Association Manual. Lower unit carefully onto roof mounting curb. A While rigging the unit, the center of gravity will cause the condenser end to be lower than the supply air end. Bring condenser end of unit into alignment 0 Y with the curb. With condenser end of the unit resting on curb member and using curb OMPRESS ompressor as a fulcrum, lower opposite end of the unit until entire unit is seated on the curb. When a OMPRESS ompressor rectangular cantilever curb is used, take care to center the unit. heck for proper alignment and orientation of supply and return openings with duct. RETURN Return EVAPAT Evaporator oil OIL G SUPPLY Supply B X D orner & enter-of-gravity Locations Weight Types ½-Ton Weights (lbs) Rigging Weights ½-Ton & 0-Ton Weights (lbs) ½-Ton Weights (lbs) Weight A Weight B 0 Weight 0 0 Weight D 0 0 Shipping Weight 0 Operating Weight 00 0 To assist in determining rigging requirements, unit weights are shown to the right. Note: These weights are calculated without accessories installed. SS-DG

24 Roof urb Installation -D View ⅜ x ⅛ Supply Opening ¼ ⅝ x ⅜ Return Opening urb installations must comply with local codes and should follow the established guidelines of the National Roofing ontractors Association. Proper unit installation requires that the roof curb be firmly and permanently attached to the roof structure. heck for adequate fastening method prior to setting the unit on the curb. ull perimeter roof curbs are available from the factory and are shipped unassembled. The installing contractor is responsible for field assembly, squaring, leveling, and mounting on the roof structure. All required hardware necessary for the assembly of the sheet metal curb is included in the curb accessory package. Determine sufficient structural support before locating and mounting the curb and package unit. Duct-work must be constructed using industry guidelines. The duct-work must be placed into the roof curb before mounting the package unit. Our full perimeter curbs include duct connection frames to be assembled with the curb. antilevered-type curbs are not available from the factory. ontractor furnishes curb insulation, cant strips, flashing, and general roofing material. Support curbs on parallel sides with roof members. To prevent damage to the unit, the roof members cannot penetrate supply and return duct openings. ¼ Note: The unit and curb accessories are designed to allow vertical duct installation before unit placement. Duct installation after unit placement is not recommended. See the manual shipped with the roof curb for assembly and installation instructions. ⅝ ¾ ⅜ Top View SS-DG

25 Wiring Diagram DG ½ ½ Tons (0V, Three-Phase Belt Drive) M T T T L L L OMP T T T T OMP T T M TR V EM OL ODE AK UE OWN ANGE RPLE RED ITE YELLOW PINK EEN EY T L R R EON II 0 DI L SEE NOTE UNUSED OOL L HEAT 0 0 SEE NOTE PB POWER SUPPLY 0-0//0 SEE NOTE IGN T T L L L H L H A T L T L RS T L B WIRING ODE ATY WIRING OPTIONAL IELD WIRING PL SEE NOTE S S R G W W Y Y O REPLAE JUMPER WITH SMOKE/IRE DETET SEE NOTE 00L00-A Wiring is subject to change. Always refer to the wiring diagram on the Warning unit for the most up-to-date wiring. High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. ailure to do so may cause property damage, personal injury, or death. SS-DG

26 Wiring Diagram DG ½ ½ Tons (0V, Three-Phase Belt Drive) L L NOTE B II H H EON OMP T T T OMP T T T EM SEE NOTE 0 D T SUPPLY 0-0//0 T T A V R M T RS M TR R IGN B B T B H L L NOTE H L R R L L A B B R M OMP EM H I II IGN L PL RS TB TR NOTES OMPONENT LEGEND AUXILLARY LIMIT SWITH OWER ONTAT OWER RELAY IRUIT EAKER OMPRESS ONTAT OMPRESS ONTAT RELAY ONDENSER MOT OMPRESS EVAPAT MOT USE AN APAIT LAME SENS EQUIPMENT OUND GAS VALVE HIGH PRESSURE SWITH INDO OWER RELAY INTEATED IGNITION ONTROL IGNIT LOW PRESSURE SWITH LIMIT SWITH EMALE PLUG/ONNET PRESSURE SWITH ROLLOUT SWITH TERMINAL OK (V SIGNAL) TRANSMER VENT MOT VENT MOT RELAY. REPLAEMENT WIRE MUST BE THE SAME SIZE AND TYPE O INSULATION AS IGINAL. (USE OPPER ONDUT ONLY).. AESSY EONOMIZER PLUG ADJAENT TO OWER HOUSING IN RETURN AIR OMPARTMENT. REMOVE MALE PLUG AND ATTAH EMALE PLUG TO THE EONOMIZER AESSY.. L AND L ON II ONTROL IS V INT.. USE OPPER ONDUTS ONLY. ++ USE NE LASS WIRE.. TWO STAGE OPERATION REMOVE W TO W JUMPER WIRE. MOVE WIRE(S) TO APPROPRIATE INT TERMINAL ON TRANSMER. WIRE ODE ATY WIRING OPTIONAL HIGH IELD WIRING AK UE OWN EEN ANGE PINK RPLE RED ITE YELLOW LINE / YELLOW WITH PINK STRIP / UE WITH PINK STRIP THERMOSTAT IELD WIRING STAGE OOLING High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. ailure to do so may cause property damage, personal injury, or death. S S TO THERMOSTAT INSTALLER/SERVIEMAN TB NOTE THE STATUS LIGHT ON THE URNAE ONTROL MAY BE USED AS A GUIDE TO TROUESHOOTING THIS APPLIANE. STATUS LIGHT ODES ARE AS OLLOWS: STATUS LIGHT ON O INK INKS INKS INKS INKS INKS O R W W Y Y G ++ NOTE EQUIPMENT STATUS NMAL OPERATION NO POWER INTERNAL ONTROL IGNITION AILURE OPEN ROLLOUT SWITH OPEN AUX. LIMIT SWITH PRESSURE SWITH OPEN PRESSURE SWITH LOSED WITHOUT INDUER ON OPEN LIMIT SWITH AE LAME SENSED OMPRESS OUTT DELAY PL HEK HEK INT POWER HEK USE ON ONTROL REPLAE ONTROL GAS LOW GAS PRESSURE GAS VALVE LAME SENS LAME ROLLOUT BAD SWITH AUX. LIMIT OPEN HEK PRESSURE SWITH HEK PRESSURE SWITH MAIN LIMIT OPEN BAD SWITH STIKING GAS VALVE MIN. OMP. ANTI-YLE TIMER SEE UNIT RATING PLATE TYPE AND SIZE O OVER URRENT PROTETION W G R Y Y W TB W G R Y Y W STAT Wiring is subject to change. Always refer to the wiring diagram on the Warning unit for the most up-to-date wiring. 0-0//0 00L0-A SS-DG

27 Wiring Diagram DG ½ ½ Tons (0V/ V, Three-Phase Belt Drive) 00L00-A Wiring is subject to change. Always refer to the wiring diagram on the Warning unit for the most up-to-date wiring. High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. ailure to do so may cause property damage, personal injury, or death. M M T T T L L L OMP T T T T OMP T T TR V EM OL ODE AK UE OWN ANGE RPLE RED ITE YELLOW PINK EEN EY T T T L L L A EON SEE NOTE II 0 L DI UNUSED OOL L HEAT IGN 0 APPROPRIATE INT 0 SEE NOTE O APPROPRIATE INT L L H H PB POWER SUPPLY 0-//0 SEE NOTE R R T L T T B L L RS WIRING ODE ATY WIRING OPTIONAL IELD WIRING SEE NOTE PL S S R G W W Y Y O REPLAE JUMPER WITH SMOKE/IRE DETET SEE NOTE SS-DG

28 Wiring Diagram DG ½ ½ Tons (0V/ V, Three-Phase Belt Drive) L L NOTE II B H H EON OMP T T SEE NOTE 0 EM D T SUPPLY 0-//0 OMP T T T T T T A V R M T 0V APPROPRIATE INT RS M TR R IGN B B T L H L NOTE R B H L R L L A B B R M OMP EM H I II IGN L PL RS TB TR NOTES OMPONENT LEGEND AUXILLARY LIMIT SWITH OWER ONTAT OWER RELAY IRUIT EAKER OMPRESS ONTAT OMPRESS ONTAT RELAY ONDENSER MOT OMPRESS EVAPAT MOT USE AN APAIT LAME SENS EQUIPMENT OUND GAS VALVE HIGH PRESSURE SWITH INDO OWER RELAY INTEATED IGNITION ONTROL IGNIT LOW PRESSURE SWITH LIMIT SWITH EMALE PLUG/ONNET PRESSURE SWITH ROLLOUT SWITH TERMINAL OK (V SIGNAL) TRANSMER VENT MOT VENT MOT RELAY. REPLAEMENT WIRE MUST BE THE SAME SIZE AND TYPE O INSULATION AS IGINAL. (USE OPPER ONDUT ONLY).. AESSY EONOMIZER PLUG ADJAENT TO OWER HOUSING IN RETURN AIR OMPARTMENT. REMOVE MALE PLUG AND ATTAH EMALE PLUG TO THE EONOMIZER AESSY.. L AND L ON II ONTROL IS V INT.. USE OPPER ONDUTS ONLY. ++ USE NE LASS WIRE.. TWO STAGE OPERATION REMOVE W TO W JUMPER WIRE. MOVE WIRE(S) TO APPROPRIATE INT TERMINAL ON TRANSMER. WIRE ODE OPTIONAL HIGH IELD WIRING AK UE OWN EEN ANGE PINK RPLE RED ITE YELLOW ATY WIRING LINE / YELLOW WITH PINK STRIP / UE WITH PINK STRIP THERMOSTAT IELD WIRING STAGE OOLING High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. ailure to do so may cause property damage, personal injury, or death. S S TO THERMOSTAT INSTALLER/SERVIEMAN NOTE THE STATUS LIGHT ON THE URNAE ONTROL MAY BE USED AS A GUIDE TO TROUESHOOTING THIS APPLIANE. STATUS LIGHT ODES ARE AS OLLOWS: STATUS LIGHT ON O INK INKS INKS INKS INKS INKS O R W W Y Y G ++ NOTE EQUIPMENT STATUS NMAL OPERATION NO POWER INTERNAL ONTROL IGNITION AILURE OPEN ROLLOUT SWITH OPEN AUX. LIMIT SWITH PRESSURE SWITH OPEN PRESSURE SWITH LOSED WITHOUT INDUER ON OPEN LIMIT SWITH AE LAME SENSED OMPRESS OUTT DELAY TB PL HEK HEK INT POWER HEK USE ON ONTROL REPLAE ONTROL GAS LOW GAS PRESSURE GAS VALVE LAME SENS LAME ROLLOUT BAD SWITH AUX. LIMIT OPEN HEK PRESSURE SWITH HEK PRESSURE SWITH MAIN LIMIT OPEN BAD SWITH STIKING GAS VALVE MIN. OMP. ANTI-YLE TIMER SEE UNIT RATING PLATE TYPE AND SIZE O OVER URRENT PROTETION W G R Y Y W TB W G R Y Y W STAT Wiring is subject to change. Always refer to the wiring diagram on the Warning unit for the most up-to-date wiring. 00V/0Hz 00L00-A SS-DG

DCG Commercial Tons Packaged Gas / Electric Units

DCG Commercial Tons Packaged Gas / Electric Units DG ommercial - Tons Packaged Gas / Electric Units Tons ooling apacity: 0,000 BTU/h 0 Tons ooling apacity: 0,000 BTU/h Tons ooling apacity: 0,000 BTU/h Tons Heating apacity: 0,000 BTU/h 0 Tons Heating apacity:

More information

ASPT Series. Multi-Position, Internal TXV. Air Handler 1½ to 5 Tons

ASPT Series. Multi-Position, Internal TXV. Air Handler 1½ to 5 Tons Series Multi-Position, Internal TXV Product Features Internal factory-installed thermal expansion valves for cooling and heat pump applications Direct drive, multi-speed ECM blower motor All-aluminum evaporator

More information

ASPT Series. Multi-Position, Internal TXV. Air Handler 1½ to 5 Tons

ASPT Series. Multi-Position, Internal TXV. Air Handler 1½ to 5 Tons Series Multi-Position, Internal TXV Multi-Speed ECM Based Air Handler ½ to Tons Contents Air Handler Nomenclature... Heater Kit Nomenclature... Product Specifications... Dimensions... Airflow Data... Heat

More information

ENVIRONMENTALLY SOUND R 410A REFRIGERANT

ENVIRONMENTALLY SOUND R 410A REFRIGERANT ENVIRONMENTALLY SOUND REFRIGERANT N4H3 Performance Series Product Specifications EFFICIENT 13 SEER HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase,

More information

GMVC8. ComfortNet -Compatible. Heating Input: 70, ,000 BTU/h. Two-Stage, Variable-Speed Gas Furnace

GMVC8. ComfortNet -Compatible. Heating Input: 70, ,000 BTU/h. Two-Stage, Variable-Speed Gas Furnace 80% AFUE Heating Input: 70,000 115,000 BTU/h ComfortNet -Compatible Two-Stage, Variable-Speed Gas Furnace Standard Features Aluminized steel, dual-diameter tubular heat exchanger Two-stage gas valve operates

More information

EFFICIENT 13 SEER HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz

EFFICIENT 13 SEER HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz ENVIRONMENTALLY SOUND REFRIGERANT N4H3 Performance Series Product Specifications EFFICIENT 13 SEER HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase,

More information

GB5BM Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Air Handler WARRANTY

GB5BM Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Air Handler WARRANTY TECHNICAL SPECIFICATIONS GB5BM Series Air Handler 13 SEER Residential System 18,000-60,000 Btuh (Heat Pump & Air Conditioner) The GB5BM Series of air handlers, when combined with our heat pump or air conditioner,

More information

BV SERIES. VERTICAL BLOWER COIL UNITS Nominal Sizes 2 thru 10 Ton

BV SERIES. VERTICAL BLOWER COIL UNITS Nominal Sizes 2 thru 10 Ton BV SERIES VERTICAL BLOWER COIL UNITS Nominal Sizes 2 thru 10 Ton MAGIC AIRE BV SERIES FAN COILS ARE ETL LISTED TO U.S. AND CANADIAN SAFETY STANDARDS AND ARE ASSEMBLED TO ORDER FOR COMPETITIVE DELIVERY.

More information

B6VMAX Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

B6VMAX Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS TECHNICAL SPECIFICATIONS B6VMAX Series Air Handler with TXV 13-19 SEER Residential System 18,000-60,000 Btuh (Heat Pump & Air Conditioner) R-410A Refrigerant The B6VMAX Series of air handlers, when combined

More information

10-year industry best core warranty. 2-year warranty on balance of unit.

10-year industry best core warranty. 2-year warranty on balance of unit. MODEL FEATURES MERV-8 filters Fully insulated case Large cores for high efficiency No condensate pan or drain required AHRI Certified Rainhood included Access door for easy maintenance and Cleaning Integral

More information

Y1SA Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

Y1SA Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS TEHNIAL SPEIFIATIONS Y1SA Series EarthDirEX Geothermal Direct Geoexchange Heat Pump ooling capacity,000 to 0,000 Heating capacity 1,000 to,000 EER 19.0 to.0 and OP.8 to.0 The Y1SA Geothermal heat pump,

More information

ENH4X. Product Specifications HORIZONTAL EVAPORATOR COILS ALL CASED N COIL MODELS WARRANTY*

ENH4X. Product Specifications HORIZONTAL EVAPORATOR COILS ALL CASED N COIL MODELS WARRANTY* ENVIRONMENTALLY SOUND REFRIGERANT ENH4X Product Specifications HORIZONTAL EVAPORATOR COILS ALL CASED N COIL MODELS 2 thru 5 Tons Available for environmentally sound R 410A systems Copper tube / aluminum

More information

579(XX).(X)(X)(X)(X) Modularized Roof Top Air Conditioner

579(XX).(X)(X)(X)(X) Modularized Roof Top Air Conditioner When ordering parts, always state: MODEL NO. - PRODUT NO. - QUANTITY - PART NUMBER - DESRIPTION For Electric Details also state: VOLTAGE - WATTAGE USA SERVIE OFFIE Dometic orporation 0 Industrial Parkway

More information

END4X, ENW4X, ENA4X. Product Specifications VERTICAL EVAPORATOR COILS ALL N COIL MODELS CASED N COILS UNCASED N COILS ENA4X WARRANTY*

END4X, ENW4X, ENA4X. Product Specifications VERTICAL EVAPORATOR COILS ALL N COIL MODELS CASED N COILS UNCASED N COILS ENA4X WARRANTY* ENVIRONMENTALLY SOUND REFRIGERANT VERTICAL EVAPORATOR COILS ALL N COIL MODELS 1½ thru 5 Tons Available for environmentally sound R 410A systems Copper tube / aluminum fin N coil with latest high tech fin

More information

Model 33SZ Basic Unit OPTIONAL FILTER RH COIL CONNECTION PRIMARY/ DEDICATED OUTDOOR AIR MULTI-POINT FLOW SENSOR 5 3/4" (146)

Model 33SZ Basic Unit OPTIONAL FILTER RH COIL CONNECTION PRIMARY/ DEDICATED OUTDOOR AIR MULTI-POINT FLOW SENSOR 5 3/4 (146) DESRIPTION: Sensible cooling coil on the induced air inlet handles zone sensible load. Opposite side to controls location. luminum ripple fins (10 PI) and 1/" (13) copper tubes. and of coil connection

More information

Product Data. CNPVP, CNRVP, CNPVT, CNRVT, CNPVU, CNRVU Evaporator Coil N Coil Cased and Uncased Upflow, Downflow

Product Data. CNPVP, CNRVP, CNPVT, CNRVT, CNPVU, CNRVU Evaporator Coil N Coil Cased and Uncased Upflow, Downflow CNPVP, CNRVP, CNPVT, CNRVT, CNPVU, CNRVU Evaporator Coil N Coil Cased and Uncased Upflow, Downflow Product Data CN(P,R)VP CN(P,R)VT (Transition) A06008 A06007 This vertical design N -coil is a furnace

More information

Product Data. CAPVU Evaporator Coil A Coil --- Uncased Upflow, Downflow CAPVU

Product Data. CAPVU Evaporator Coil A Coil --- Uncased Upflow, Downflow CAPVU CAPVU Evaporator Coil A Coil --- Uncased Upflow, Downflow Product Data CAPVU A06002 The CAPVU evaporator coils incorporate proven standards for reliable system operation and performance throughout the

More information

DCG Commercial Tons Packaged Gas / Electric Units

DCG Commercial Tons Packaged Gas / Electric Units D ommercial - Tons Packaged as / Electric Units Tons ooling apacity: 0,000 BTU/h 0 Tons ooling apacity: 0,000 BTU/h Tons ooling apacity: 0,000 BTU/h Tons Heating apacity: 0,000 BTU/h 0 Tons Heating apacity:

More information

4HP13 PRODUCT SPECIFICATIONS 13 SEER SPLIT SYSTEM HEAT PUMP WARRANTY

4HP13 PRODUCT SPECIFICATIONS 13 SEER SPLIT SYSTEM HEAT PUMP WARRANTY 4HP13 PRODUCT SPECIFICATIONS 13 S SPLIT SYSTEM HEAT PUMP FORM NO. 4HP13-100 (07/2014) R410A Refrigerant High-quality condenser coil with copper tubing and enhanced louvered fin for maximum heat transfer

More information

REPAIR PARTS. GPH14 H-SERIES R-410A Package Heat Pumps GPH1424H41AA GPH1430H41AA GPH1436H41AA GPH1442H41AA GPH1448H41AA GPH1460H41AA

REPAIR PARTS. GPH14 H-SERIES R-410A Package Heat Pumps GPH1424H41AA GPH1430H41AA GPH1436H41AA GPH1442H41AA GPH1448H41AA GPH1460H41AA REPAIR PARTS GPH14 H-SERIES R-0A Package Heat Pumps GPH1424HAA GPH1430HAA GPH1436HAA GPH1442HAA GPH1448HAA GPH1460HAA This manual is to be used by qualified technicians only. 2009 Goodman Manufacturing

More information

42C/V. Fan Coil Unit 42C/V

42C/V. Fan Coil Unit 42C/V 2/V Fan oil Unit 2/V arrier makes the world a better place to live by creating a comfortable, productive and healthy environment regardless of climate. It is our mission is to be customer s first choice

More information

Product Data. CNPHP, CNRHP Evaporator Coil N Coil --- Cased Horizontal CNPHP / CNRHP

Product Data. CNPHP, CNRHP Evaporator Coil N Coil --- Cased Horizontal CNPHP / CNRHP CNPHP, CNRHP Evaporator Coil N Coil --- Cased Horizontal Product Data 06005 This horizontal design N -coil is an evaporator coil designed to provide the highest standards of reliability and durability.

More information

Two-Stage, Variable-Speed Gas Furnace

Two-Stage, Variable-Speed Gas Furnace 80% AFUE GMV8 Two-Stage, Variable-Speed Gas Furnace Heating Input: 60,000 00,000 BTU/h Standard Features Aluminized steel, dual-diameter tubular heat exchanger Two-stage gas valve operates on two-stage

More information

R- 410A R-22 Size (tons) Shipping Weight (lbs) WLAU184AA 1-1/ WLAU182AA 1-1/ WLAU244AA. Model /2

R- 410A R-22 Size (tons) Shipping Weight (lbs) WLAU184AA 1-1/ WLAU182AA 1-1/ WLAU244AA. Model /2 EVAPORATOR COILS A COIL - UNCASED R- 410A or R- 22 SYSTEMS 1 1/2 5 Tons WLAU Use of the AHRI Certified TM Mark indicates a manufacturer s participation in the program. For verification of certification

More information

McQuay. Water Source Heat Pump. VF, VG, VP Vintage E, F, G. Last Manufactured: Replacement Parts List No Revision B 02/2017

McQuay. Water Source Heat Pump. VF, VG, VP Vintage E, F, G. Last Manufactured: Replacement Parts List No Revision B 02/2017 Replacement s List No. 055206700 Revision B 02/2017 McQuay Water Source Heat Pump VF, VG, VP 240-390 Vintage E, F, G Last Manufactured: 1992 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

ASTON SERIES AIR HANDLER

ASTON SERIES AIR HANDLER ASTN SEIES AI HANDLE HYDNI AND -0A T TNS Submittal Data English Language IP/Metric Units SD00H 0/ ontractor: P..: - Tons 0Hz Model Nomenclature - - - 0 AH 0 * 00 0 Model AH Series Air Handler Unit apacity

More information

REPAIR PARTS. GPH13 "M" Series Horizontal Package Heat Pumps GPH1324M41AA GPH1330M41AA GPH1336M41AA GPH1342M41AA GPH1348M41AA GPH1360M41AA

REPAIR PARTS. GPH13 M Series Horizontal Package Heat Pumps GPH1324M41AA GPH1330M41AA GPH1336M41AA GPH1342M41AA GPH1348M41AA GPH1360M41AA REPAIR PARTS GPH13 "M" Series Horizontal Package Heat Pumps GPH1324MAA GPH1330MAA GPH1336MAA GPH1342MAA GPH1348MAA GPH1360MAA This manual is to be used by qualified technicians only. 2009 Goodman Manufacturing

More information

REPAIR PARTS. GPC13 "M" Series 3-5 Ton Package Coolers

REPAIR PARTS. GPC13 M Series 3-5 Ton Package Coolers REPAIR PARTS GPC13 "M" Series 3-5 Ton Package Coolers GPC1336MAA GPC1336MBA GPC1336MCA GPC1336M43AA GPC1348MAA GPC1348MBA GPC1348MCA GPC1348M43AA GPC1348M43BA GPC1360MAA GPC1360MBA GPC1360MCA GPC1360M43AA

More information

Parts Manual R410A Models

Parts Manual R410A Models Parts Manual R410A Models PTAC - PD Series (Electronic Controls) Packaged Terminal Air Conditioners Packaged Terminal Heat Pumps PTAC PARTS E (1-2010) Table of Contents Unit Identification... 2 PTAC System

More information

GMVM96 / GCVM96 ComfortNet -Compatible, Multi-Position, Modulating Variable-Speed Gas Furnace

GMVM96 / GCVM96 ComfortNet -Compatible, Multi-Position, Modulating Variable-Speed Gas Furnace / GVM96 omfortnet -ompatible, Multi-Position, Modulating Variable-Speed Gas Furnace Up to 96% AFUE abinet Features Multi-position installation: upflow, horizontal left or right ertified for direct vent

More information

3 Port, 2-Ton Outdoor Heat Pump

3 Port, 2-Ton Outdoor Heat Pump Job Name: Tag# Submittal Data Sheet 3 Port, 2-Ton Outdoor Heat Pump 3MXS24NMVJU Efficiency SEER EER HSPF Non-Ducted 17.9 12.7 12.5 Ducted 14 9.7 8.2 Mixed 15.95 11.2 10.35 Performance Cooling (Btu/hr)

More information

Singer. Incremental Comfort Systems. K, EK Vintage F. Last Manufactured: Replacement Parts List No Revision C 04/2012

Singer. Incremental Comfort Systems. K, EK Vintage F. Last Manufactured: Replacement Parts List No Revision C 04/2012 Replacement Parts List No. 055231000 Revision C 04/2012 Singer Incremental Comfort Systems K, EK 07-15 Vintage F Last Manufactured: 1976 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

REPAIR PARTS. GPC15 Horizontal Package Cooling Units

REPAIR PARTS. GPC15 Horizontal Package Cooling Units REPAIR PARTS GPC15 Horizontal Package Cooling Units GPC1524H41AA GPC1524H41AB GPC1530H41AA GPC1530H41AB GPC1536H41AA GPC1536H41AB GPC1542H41AA GPC1542H41AB GPC1548H41AA GPC1548H41AB GPC1560H41AA GPC1560H41AB

More information

REPAIR PARTS. GPH13 "H" Model Package Heat Pumps GPH1324H41AB GPH1330H41AB GPH1336H41AB GPH1342H41AB GPH1348H41BB GPH1360H41BB

REPAIR PARTS. GPH13 H Model Package Heat Pumps GPH1324H41AB GPH1330H41AB GPH1336H41AB GPH1342H41AB GPH1348H41BB GPH1360H41BB REPAIR PARTS GPH13 "H" Model Package Heat Pumps GPH1324H41AB GPH1330H41AB GPH1336H41AB GPH1342H41AB GPH1348H41BB GPH1360H41BB This manual is to be used by qualified technicians only. 2010 Goodman Manufacturing

More information

REPAIR PARTS. GPG14 "M" Series Residential Package Gas Units. This manual is to be used by qualified technicians only. This manual replaces RP-G3001.

REPAIR PARTS. GPG14 M Series Residential Package Gas Units. This manual is to be used by qualified technicians only. This manual replaces RP-G3001. REPAIR PARTS GPG14 "M" Series Residential Package Gas Units GPG1424040MAA GPG1424040MAB GPG1424060MAA GPG1424060MAB GPG1430040MAA GPG1430040MAB GPG1430060MAA GPG1430060MAB GPG1436040MAA GPG1436040MAB GPG1436060MAA

More information

REPAIR PARTS. DP13CH Residential Package Heat Pump

REPAIR PARTS. DP13CH Residential Package Heat Pump REPAIR PARTS DP13CH Residential Package Heat Pump DP13CH24AA DP13CH24AB DP13CH30AA DP13CH30AB DP13CH36AA DP13CH36AB DP13CH42AA DP13CH42AB DP13CH48AA DP13CH48AB DP13CH60AA DP13CH60AB nufacturing Company,

More information

REPAIR PARTS. A/GPG13 Package Gas Units

REPAIR PARTS. A/GPG13 Package Gas Units REPAIR PARTS A/GPG13 Package Gas Units APG1324045MBA APG1324070MBA APG1330045MBA APG1330070MBA APG1336045MBA APG1336070MBA APG1336090MBA APG1342070MBA APG1342090MBA APG1348070MBA APG1348090MBA APG13485MBA

More information

Energy Efficient Easy to Install Extended Service Life. Horizontal Direct Drive Blower Coils BUILD YOUR REPUTATION ON OURS

Energy Efficient Easy to Install Extended Service Life. Horizontal Direct Drive Blower Coils BUILD YOUR REPUTATION ON OURS Energy Efficient Easy to Install Extended Service Life Energy efficient compact blower coils Ideal for educational, hospitality, multi-family, or other commercial environments Designed for ducted applications

More information

PARTS MANUAL Gas Furnace F8MXN, F8MXL, G8MXN, G8MXL

PARTS MANUAL Gas Furnace F8MXN, F8MXL, G8MXN, G8MXL Gas Furnace F8MXN, F8MXL, G8MXN, G8MXL DANGER, WARNING, CAUTION, and NOTE The signal words DANGER, WARNING, CAU- TION, and NOTE are used to identify levels of hazard seriousness. The signal word DANGER

More information

nufacturing Company, L.P San Felipe, Suite 500

nufacturing Company, L.P San Felipe, Suite 500 REPAIR PARTS AWUF Vertical Mount Air Handlers AWUF18051AA AWUF18051BA AWUF180516AA AWUF18081AA AWUF18081BA AWUF180816AA AWUF24051AA AWUF24051BA AWUF240516AA AWUF24081AA AWUF24081BA AWUF240816AA AWUF201AA

More information

Parts. Package Terminal Air Conditioner. Models and manufacturing numbers in this manual. This manual replaces RP revision 0.

Parts. Package Terminal Air Conditioner. Models and manufacturing numbers in this manual. This manual replaces RP revision 0. s Package Terminal Air Conditioner This manual replaces RP40017 revision 0. PTC073A00AC PTC073A15AC PTC073A25AC PTC073A35AB PTC073A35AC PTC093A00AC PTC093A15AC PTC093A25AC PTC093A35AB PTC093A35AC PTC093A50AC

More information

REPAIR PARTS. GPH14 H-Series Package Heat Pumps. This manual is to be used by qualified technicians only. This manual replaces RP-631C.

REPAIR PARTS. GPH14 H-Series Package Heat Pumps. This manual is to be used by qualified technicians only. This manual replaces RP-631C. REPAIR PARTS GPH14 H-Series Package Heat Pumps GPH1424H41AB GPH1424H41AC GPH1424H41BA GPH1424H41CA GPH1424H41DA GPH1430H41AB GPH1430H41AC GPH1430H41BA GPH1430H41CA GPH1436H41AB GPH1436H41AC GPH1436H41BA

More information

REPAIR PARTS. GPH H-SERIES Package Heat Pumps

REPAIR PARTS. GPH H-SERIES Package Heat Pumps REPAIR PARTS GPH H-SERIES Package Heat Pumps GPH1324HAB GPH1324HAC GPH1324HAD GPH1324HA GPH1330HAB GPH1330HAC GPH1330HAD GPH1330HA GPH1336HAB GPH1336HAC GPH1336HAD GPH1336HAE GPH1336HA GPH1342HAB GPH1342HAC

More information

REPAIR PARTS. *PD14 Dual Fuel Package Units

REPAIR PARTS. *PD14 Dual Fuel Package Units *PD14 Dual Fuel Package Units APD1424070M41AA APD1424070M41BA APD1430090M41AA APD1430090M41BA APD1436090M41AA APD1436090M41BA APD1437090M41AA APD14425M41AA APD14425M41BA APD14485M41AA APD14485M41BA GPD1424070M41AA

More information

REPAIR PARTS 14 SEER DUEL FUEL PACKAGE MODELS

REPAIR PARTS 14 SEER DUEL FUEL PACKAGE MODELS 14 SEER DUEL FUEL PACKAGE MODELS APD1424070M41AA APD1430090M41AA APD1436090M41AA APD14425M41AA APD14485M41AA GPD1424070M41AA GPD1430090M41AA GPD1436090M41AA GPD14425M41AA GPD14485M41AA REPAIR PARTS This

More information

REPAIR PARTS. GPH14 "M" Series Residential Package Heat Pump. This manual is to be used by qualified technicians only.

REPAIR PARTS. GPH14 M Series Residential Package Heat Pump. This manual is to be used by qualified technicians only. REPAIR PARTS GPH14 "M" Series Residential Package Heat Pump GPH1424MAA GPH1430MAA GPH1436MAA GPH1442MAA GPH1448MAA GPH1460MAA nufacturing Company, L.P. 5151 San Felipe, Suite 500 www.amana-hac.com www.amana-hac.com

More information

REPAIR PARTS. GPH16 Horizontal Package Heat Pumps. This manual is to be used by qualified technicians only.

REPAIR PARTS. GPH16 Horizontal Package Heat Pumps. This manual is to be used by qualified technicians only. REPAIR PARTS GPH16 Horizontal Package Heat Pumps GPH1624H41AA GPH1630H41AA GPH1636H41AA GPH1642H41AA GPH1648H41AA nufacturing Company, L.P. 5151 San Felipe, Suite 500 www.amana-hac.com www.amana-hac.com

More information

REPAIR PARTS. GPH14 "H" Residential Package Heat Pump

REPAIR PARTS. GPH14 H Residential Package Heat Pump REPAIR PARTS GPH14 "H" Residential Package Heat Pump GPH1424H41AB GPH1424H41AC GPH1424H41BA GPH1424H41CA GPH1424H41DA GPH1424H41DB GPH1430H41AB GPH1430H41AC GPH1430H41BA GPH1430H41CA GPH1430H41DB GPH1436H41AB

More information

REPAIR PARTS. GPH14 Multi-Position Residential Package Heat Pump. This manual is to be used by qualified technicians only.

REPAIR PARTS. GPH14 Multi-Position Residential Package Heat Pump. This manual is to be used by qualified technicians only. REPAIR PARTS GPH14 Multi-Position Residential Package Heat Pump GPH1424MAA GPH1424MAB GPH1430MAA GPH1430MAB GPH1436MAA GPH1436MAB GPH1442MAA GPH1442MAB GPH1448MAA GPH1448MAB GPH1460MAA GPH1460MAB This

More information

Product Data CNPVP, CNPVT, CNPVU, CNRVU EVAPORATOR COIL N COIL - CASED AND UNCASED UPFLOW, DOWNFLOW

Product Data CNPVP, CNPVT, CNPVU, CNRVU EVAPORATOR COIL N COIL - CASED AND UNCASED UPFLOW, DOWNFLOW CNPVP, CNPVT, CNPVU, CNRVU EVPORTOR COIL N COIL - CSED ND UNCSED UPFLOW, DOWNFLOW Product Data CNPVP CNPVT (Transition) CN(P,R)VU 06008 06007 06004 This vertical design N -coil is a furnace coil designed

More information

INSTALLATION INSTRUCTIONS ATV Plow Blade Part Number: (50 ), (54 ), or (60 ) Application: All Terrain Vehicles

INSTALLATION INSTRUCTIONS ATV Plow Blade Part Number: (50 ), (54 ), or (60 ) Application: All Terrain Vehicles INSTALLATION INSTRUCTIONS ATV Plow Blade Part Number: 78950 (50 ), 78954 (54 ), or 78960 (60 ) Application: All Terrain Vehicles Your safety, and the safety of others, is very important. To help you make

More information

McQuay Climate Control Singer. Incremental. NE, NH, NR Vintages C, D. TYA, TAA Vintages A, B. Last Manufactured: 1999

McQuay Climate Control Singer. Incremental. NE, NH, NR Vintages C, D. TYA, TAA Vintages A, B. Last Manufactured: 1999 Replacement Parts List No. 055233900 Revision D 08/2017 McQuay Climate Control Singer Incremental NE, NH, NR 07-18 Vintages C, D TYA, TAA 007-015 Vintages A, B Last Manufactured: 1999 To find your Daikin

More information

Solenoid valves Type EVUL

Solenoid valves Type EVUL Data sheet Solenoid valves EVUL EVUL solenoid valves are designed to fit into compact refrigeration systems. Available in servo operated versions they can be applied in liquid, suction, and hot gas lines.

More information

THE ENERGY 68,SAVING TDVI. exible Combine Modular 24, 26, 28, 30, 32, 34, 36, 38, 40, 42, 44 HP 60, 62, 64, 66 HP

THE ENERGY 68,SAVING TDVI. exible Combine Modular 24, 26, 28, 30, 32, 34, 36, 38, 40, 42, 44 HP 60, 62, 64, 66 HP I N V E RT E R ion Range exible Combine Modular TDV I TDV I TDV I INVERTER INVERTER INVERTER 14, 16, 18, 20, 22 HP TDV I 24, 26, 28, 30, 32, 34, 36, 38, 40, 42, 44 HP INVERTER INVERTER INVERTER TDV I INVERTER

More information

Series 3000 and XE-Series Engineering Data

Series 3000 and XE-Series Engineering Data Series 3000 and XE-Series Engineering Data A C A U S T R A L I A Series 3000 and XE-Series Engineering Data The NEW era of Series 3000 and XE-Series Cooling Towers continue to exceed the industry standard

More information

HEAT CONTENT DECREASES U D R HEAT CONTENT INCREASESO. Btu/lb

HEAT CONTENT DECREASES U D R HEAT CONTENT INCREASESO. Btu/lb Pressure (psia) LINES OF CONSTANT ENTHALPY PRESSURE P R E S S U R E R I S E S P R E S S HEAT CONTENT DECREASES U R E D R HEAT CONTENT INCREASESO P S Btu/lb Heat Content Pressure (psia) SATURATION CURVE

More information

nufacturing Company, L.P San Felipe, Suite

nufacturing Company, L.P San Felipe, Suite Mini-Split Heat Pump Outdoor Unit RXS09LVJU RXS12LVJU RXS15LVJU RXS18LVJU RXS24LVJU REPAIR PARTS nufacturing Company, L.P. 5151 San Felipe, Suite 500 www.amana-hac.com www.amana-hac.com This manual is

More information

REPAIR PARTS. [A/G]PG15 Package Gas-Electric Units

REPAIR PARTS. [A/G]PG15 Package Gas-Electric Units REPAIR PARTS [A/G]PG15 Package Gas-Electric Units APG152407041AA APG153009041AA APG153609041AA APG153609041AB APG153709041AA APG1542541AA APG1548541AA APG1548541AB APG1549541AA APG156014041AA APG156014041AB

More information

REPAIR PARTS. GPC14 H-Series Package Cooling Units. This manual is to be used by qualified technicians only. This manual replaces RP-622C.

REPAIR PARTS. GPC14 H-Series Package Cooling Units. This manual is to be used by qualified technicians only. This manual replaces RP-622C. REPAIR PARTS GPC14 H-Series Package Cooling Units GPC1424H41AB GPC1424H41AC GPC1424H41BA GPC1424H41CA GPC1424H41DA GPC1430H41AB GPC1430H41AC GPC1430H41BA GPC1430H41CA GPC1430H41DA GPC1436H41AB GPC1436H41BA

More information

(HSI) LIMITED WARRANTY

(HSI) LIMITED WARRANTY ama The Payne PG8MAA/JAA 80% AFUE Gas Furnaces feature 4-way multipoise design and through-the-furnace downflow venting. The PG8MAA/JAA furnaces are approved f use with natural propane gas, and the PG8JAA

More information

PARTS MANUAL Gas Furnace F9MAC, G9MAC

PARTS MANUAL Gas Furnace F9MAC, G9MAC Gas Furnace F9MAC, G9MAC Safety Labeling and Signal Words DANGER, WARNING, CAUTION, and NOTE The signal words DANGER, WARNING, CAUTION, and NOTE are used to identify levels of hazard seriousness. The signal

More information

ANSI/AHRI Standard 1250 (I-P) 2014 Standard for Performance Rating of Walk-in Coolers and Freezers

ANSI/AHRI Standard 1250 (I-P) 2014 Standard for Performance Rating of Walk-in Coolers and Freezers ANSI/AHRI Standard 1250 (I-P) 2014 Standard for Performance Rating of Walk-in Coolers and Freezers Approved by ANSI on May 19, 2015 - ERRATA SHEET FOR, PERFORMANCE RATING OF WALK-IN COOLERS AND FREEZERS

More information

SECTION 1 - WHAT IS A BTU METER? BTU's = Flow x ΔT Any ISTEC BTU Meter System consists of the following main components:

SECTION 1 - WHAT IS A BTU METER? BTU's = Flow x ΔT Any ISTEC BTU Meter System consists of the following main components: SECTION 1 - WHAT IS A BTU METER? ISTEC BTU Meters measure energy usage by multiplying flow rate and temperature difference. As the water (or other liquid) passes through these lines, the multi-wing turbine

More information

VRF Technical Data Book

VRF Technical Data Book VRF Technical Data Book DVM S for Euro_ET (R4A, Hz, HP) Model : Premium (Compact / Energy Efficiency) Type Standard Type History Version Modification Date Remark Ver. 1. Release DVM S (R4A, Hz, HP) for

More information

McQuay Climate Control. Water Source Heat Pump Horizontal. CC, CG, CW Vintage C, D. Last Manufactured: 1984

McQuay Climate Control. Water Source Heat Pump Horizontal. CC, CG, CW Vintage C, D. Last Manufactured: 1984 Replacement Parts List No. 055204000 Revision C 01/2017 McQuay Climate Control Water Source Heat Pump Horizontal CC, CG, CW 260-330 Vintage C, D Last Manufactured: 1984 To find your Daikin Applied parts

More information

REPAIR PARTS. GPG13 "M" Series Package Gas Unit

REPAIR PARTS. GPG13 M Series Package Gas Unit REPAIR PARTS GPG13 "M" Series Package Gas Unit GPG1324045MAA GPG1324070MAA GPG1330045MAA GPG1330070MAA GPG1336045MAA GPG1336070MAA GPG1336090MAA GPG1336090M43AA GPG1342070MAA GPG1342090MAA GPG1348070MAA

More information

ClimateMaster s Tranquility 22. Raj Hiremath Director of Residential Marketing

ClimateMaster s Tranquility 22. Raj Hiremath Director of Residential Marketing ClimateMaster s Tranquility 22 Raj Hiremath Director of Residential Marketing 1 CLIMATEMASTER Industry leader since 1950 s First to introduce 2-stage 27 EER unit First to introduce Outdoor split system

More information

REPAIR PARTS. DX17VS Outdoor Inverter. This manual is to be used by qualified technicians only.

REPAIR PARTS. DX17VS Outdoor Inverter. This manual is to be used by qualified technicians only. REPAIR PARTS DX17VS Outdoor Inverter DX17VSS181AA DX17VSS241AA DX17VSS01AA DX17VSS61AA DX17VSS421AA DX17VSS481AA DX17VSS601AA This manual is to be used by qualified technicians only. 2018 5151 San Felipe

More information

REPAIR PARTS. AMH95 Amana brand 95% Hybrid Furnace AMH950453BXAA AMH950703BXAA AMH950704CXAA AMH950904CXAA AMH950905DXAA AMH951155DXAA

REPAIR PARTS. AMH95 Amana brand 95% Hybrid Furnace AMH950453BXAA AMH950703BXAA AMH950704CXAA AMH950904CXAA AMH950905DXAA AMH951155DXAA REPAIR PARTS AMH95 Amana brand 95% Hybrid Furnace AMH950453BXAA AMH950703BXAA AMH950704CXAA AMH950904CXAA AMH950905DXAA AMH9155DXAA Amana is a trademark of Maytag Corporation and used under license to

More information

PRODUCT SPECIFICATIONS

PRODUCT SPECIFICATIONS GMV95/GV9 SERIES UP TO 95% FUE MULTI-POSITION, 2-STGE/VRILE-SPEE GS FURNE HETING PITY: 46,000 115,000 TUH GMV95 Models Qualify for a $200 Tax redit GV9 Models Qualify for a $50 Tax redit Standard Features

More information

5. DRIVE 1. SAFETY 2. PREPARATION 3. FRAME 4. TRANSMISSION 6. ROW UNIT 7. OPTIONAL EQUIPMENT

5. DRIVE 1. SAFETY 2. PREPARATION 3. FRAME 4. TRANSMISSION 6. ROW UNIT 7. OPTIONAL EQUIPMENT TABLE OF CONTENTS 1. SAFETY 2. PREPARATION 3. FRAME 4. TRANSMISSION 5. DRIVE 6. ROW UNIT 7. OPTIONAL EQUIPMENT DRIVE Standard Turbofan 540, 450 & 1000 RPM with PTO Drive Your Monosem planter will be equipped

More information

AIR CONDITIONER (SPLIT TYPE) SERVICE MANUAL

AIR CONDITIONER (SPLIT TYPE) SERVICE MANUAL AIR CONDITIONER (SPLIT TYPE) SERVICE MANUAL FILE No. A10-023-1 REVISION 1 : Mar.2012 Re-edit version.( file volume down) Contents have NOT been changed. Model name: RAS-M10PKVP-E RAS-M13PKVP-E RAS-M16PKVP-E

More information

REPAIR PARTS. GMS95 Single Stage Upflow Furnace GMS950453BXAB GMS950703BXAB GMS950704CXAB GMS950904CXAB GMS951155DXAB.

REPAIR PARTS. GMS95 Single Stage Upflow Furnace GMS950453BXAB GMS950703BXAB GMS950704CXAB GMS950904CXAB GMS951155DXAB. REPAIR PARTS GMS95 Single Stage Upflow Furnace GMS950453BXAB GMS950703BXAB GMS950704CXAB GMS950904CXAB GMS55DXAB Made in the USA by: Goodman Manufacturing Company, L.P. 2550 North Loop West, Suite 400

More information

nufacturing Company, L.P San Felipe, Suite

nufacturing Company, L.P San Felipe, Suite REPAIR PARTS (2,3,4) Multi Zone Heat Pump Outdoor Unit 2MXS18GVJUAA 3MXS24JVJUAA 4MXS32GVJUAA nufacturing Company, L.P. 5151 San Felipe, Suite 500 www.amana-hac.com www.amana-hac.com This manual is to

More information

HVAC Electrical Wiring Diagrams / Ohm s Law / Sequence of Operation RV

HVAC Electrical Wiring Diagrams / Ohm s Law / Sequence of Operation RV PLEASE DO NOT BOOKMARK ANY ANYTIMECE WEBPAGES! Our system will remember the last page you viewed when logging out and back in but please DO NOT exit out when taking a test. Your place will NOT be saved.

More information

Repair Parts List DUEL FUEL RANGE MODEL NUMBER SVD48600BC. When requesting service or ordering parts, always provide the following information:

Repair Parts List DUEL FUEL RANGE MODEL NUMBER SVD48600BC. When requesting service or ordering parts, always provide the following information: Repair Parts List DUEL FUEL RANGE MODEL NUMBER SVD48600BC When requesting service or ordering parts, always provide the following information: - Product Type - Part Number - Model Number - Part Description

More information

McQuay Climate Control Singer

McQuay Climate Control Singer Replacement Parts List No. 055204800 Revision B 01/2017 McQuay Climate Control Singer Vertical Water Source Heat Pump FC, FG, FW 240, 330, 400, 500 Vintages C, D Last Manufactured: 1986 To find your Daikin

More information

REPAIR PARTS. GDH8 80% Two-Stage Hybrid Dedicated Downflow Gas Furnace

REPAIR PARTS. GDH8 80% Two-Stage Hybrid Dedicated Downflow Gas Furnace REPAIR PARTS GDH8 80% Two-Stage Hybrid Dedicated Downflow Gas Furnace GDH80453AXAA GDH80453AXAB GDH80453AXAC GDH80703AXAA GDH80703AXAB GDH80703AXAC GDH80904BXAA GDH80904BXAB GDH80904BXAC GDH155CXAA GDH155CXAB

More information

REPAIR PARTS. ARUF Aluminum Coil Air Handler

REPAIR PARTS. ARUF Aluminum Coil Air Handler REPAIR PARTS ARUF Aluminum Coil Air Handler ARUF172916CA ARUF186CA ARUF193116CA ARUF303016CA ARUF363616CA ARUF364216CA ARUF374316CA ARUF486016CA ARUF496116CA This manual is to be used by qualified technicians

More information

INSTALLATION INSTRUCTIONS PLOW MOUNT KIT Part Number: Application: Honda Foreman 500

INSTALLATION INSTRUCTIONS PLOW MOUNT KIT Part Number: Application: Honda Foreman 500 WARN INDUSTRIES, INC. 12900 S.E. Capps Road, Clackamas, OR USA 97015-8903, 1-503-722-1200, FAX: 1-503-722-3000 Customer Service: 1-800-543-9276 Dealer Locator Service: 1-800-910-1122 International Sales/Customer

More information

Flexitest Switch Assemblies Type FT-19R and FT-19RX Supersedes DB March 2008

Flexitest Switch Assemblies Type FT-19R and FT-19RX Supersedes DB March 2008 Flexitest Switch Assemblies Type FT-19R and FT-19RX Supersedes DB41-078 March 2008 FT-19R and FT-19RX FT-19R 3RU with Individual Clear Covers APPLICATION FEATURES The type FT-19R (standard length) and

More information

SUBMITTAL DATA: MXZ-3C30NA MULTI-INDOOR INVERTER HEAT-PUMP SYSTEM

SUBMITTAL DATA: MXZ-3C30NA MULTI-INDOOR INVERTER HEAT-PUMP SYSTEM Job Name: System Reference: SUBMITTAL DATA: MXZ-3C30NA MULTI-INDOOR INVERTER HEAT-PUMP SYSTEM M-SERIES Date: GENERAL FEATURES Quiet Operation Optional base pan heater to prevent ice in drain pan Limited

More information

REPAIR PARTS. AVPTC Air Handler. This manual is to be used by qualified technicians only. This manual replaces RP-775E.

REPAIR PARTS. AVPTC Air Handler. This manual is to be used by qualified technicians only. This manual replaces RP-775E. REPAIR PARTS AVPTC Air Handler AVPTC24B14AA AVPTC24B14AB AVPTC24B14AC AVPTC30C14AA AVPTC30C14AB AVPTC36C14AA AVPTC36C14AB AVPTC42D14AA AVPTC42D14AB AVPTC42D14AC AVPTC48C14AA AVPTC48C14AB AVPTC48D14AA AVPTC48D14AB

More information

Parts List, Wiring Diagrams

Parts List, Wiring Diagrams Parts List, Wiring Diagrams PAE180-300 SERIES PACKAGE AIR CONDITIONER UNITS TABLE OF CONTENTS PARTS LIST----------- 2-11 PARTS DRAWING----- 12-34 WIRING DIAGRAMS--- 35-48 Printed in U.S.A. 7/28/08 KEY

More information

REPAIR PARTS. DZ13SA Remote Heat Pumps (3-Phase) DZ13SA0363AA DZ13SA0483AA DZ13SA0484AA DZ13SA0603AA DZ13SA0604AA

REPAIR PARTS. DZ13SA Remote Heat Pumps (3-Phase) DZ13SA0363AA DZ13SA0483AA DZ13SA0484AA DZ13SA0603AA DZ13SA0604AA DZ13SA Remote Heat Pumps (3-Phase) DZ13SA0363AA DZ13SA0483AA DZ13SA0484AA DZ13SA0603AA DZ13SA0604AA REPAIR PARTS This manual is to be used by qualified technicians only. 2013 Daikin Manufacturing Company,

More information

REPAIR PARTS. APG10*A 10 SEER Package Gas Unit

REPAIR PARTS. APG10*A 10 SEER Package Gas Unit REPAIR PARTS APG10*A 10 SEER Package Gas Unit APG102404A APG10240701A APG10300701A APG10360701A APG10360901A APG10360903A APG10420701A APG10420901A APG10480901A APG10480903A APG1048A APG10600901A APG10600903A

More information

Ductless Split Systems Floating Air

Ductless Split Systems Floating Air Ductless Split Systems Floating Air PURCHASER P.O. # DATE PROJECT LOCATION ENGINEER ARCHITECT SUBMITTED BY FOR APPROVAL FOR REFERENCE ITEM PLAN DESIGNATION QUANTITY COOLING BTU/H VOLTAGE FRIEDRICH MODEL

More information

REPAIR PARTS. ARPT Air Handlers

REPAIR PARTS. ARPT Air Handlers REPAIR PARTS ARPT Air Handlers ARPT18B14AA ARPT18B14AB ARPT24B14AA ARPT24B14AB ARPT30B14AA ARPT30B14AB ARPT36C14AA ARPT36C14AB ARPT36D14AA ARPT36D14AB ARPT42D14AA ARPT42D14AB ARPT48D14AA ARPT48D14AB ARPT60D14AA

More information

SUBMITTAL DATA: MXZ-5C42NA MULTI-INDOOR INVERTER HEAT PUMP SYSTEM

SUBMITTAL DATA: MXZ-5C42NA MULTI-INDOOR INVERTER HEAT PUMP SYSTEM Job Name: System Reference: SUBMITTAL DATA: MXZ-5C42NA MULTI-INDOOR INVERTER HEAT PUMP SYSTEM M-SERIES Date: GENERAL FEATURES Quiet Operation Optional base pan heater to prevent ice in drain pan Limited

More information

REPAIR PARTS. GMV9* Variable Speed Furnace

REPAIR PARTS. GMV9* Variable Speed Furnace REPAIR PARTS GMV9* Variable Speed Furnace GMV90703BXBA GMV90905CXBA GMV155DXBA GMV950453BXBA GMV950453BXBB GMV950704CXBA GMV950704CXBB GMV950905DXBA GMV950905DXBB GMV9155DXBA GMV9155DXBB GMV9155DXBC Goodman

More information

TOLERANCES AND UNCERTAINTIES IN PERFORMANCE DATA OF REFRIGERANT COMPRESSORS JANUARY 2017

TOLERANCES AND UNCERTAINTIES IN PERFORMANCE DATA OF REFRIGERANT COMPRESSORS JANUARY 2017 TOLERANCES AND UNCERTAINTIES IN PERFORMANCE DATA OF REFRIGERANT COMPRESSORS JANUARY 017 111 Wilson Blvd, Suite 500 Arlington, Virginia 01 USA +001 (703) 54-8800 Published by: TABLE OF CONTENTS SECTION

More information

Solenoid valve Types CSV 2 - CSV 22 (NC) and solenoid coil

Solenoid valve Types CSV 2 - CSV 22 (NC) and solenoid coil Data sheet Solenoid valve s CSV 2 - CSV 22 (NC) and solenoid coil CSV is a direct or servo-operated solenoid valve for liquid, suction, and hot gas lines with fluorinated refrigerants. CSV valves are for

More information

PARTS LIST WATER SOURCE HEAT PUMPS HLH/HLV

PARTS LIST WATER SOURCE HEAT PUMPS HLH/HLV PARTS LIST WATER SOURCE HEAT PUMPS HLH/HLV 1900 Wellworth Ave. Jackson, MI 49203 www.heatcontroller.com 517-787-2100 HLH PARTS LIST 072 096 120 Part # Item Description 3 3 3 3 3 3 3 3 Compressors 68832733

More information

AIR COOLED CONDENSING UNIT

AIR COOLED CONDENSING UNIT EVOLUTION SERIES AIR COOLED CONDENSING UNIT OUTDOOR AIR COOLED CONDENSING UNIT ORIGINAL MANUFACTURED EQUIPMENT Evolution Series BA-503-3 AUS Evolution Air Cooled Condensing Unit Series Content Page Explanation

More information

REPAIR PARTS. CPLT 13 SEER Series Condensing Units CPLT24-1 CPLT24-1A CPLT30-1 CPLT30-1A CPLT36-1 CPLT42-1 CPLT48-1 CPLT60-1

REPAIR PARTS. CPLT 13 SEER Series Condensing Units CPLT24-1 CPLT24-1A CPLT30-1 CPLT30-1A CPLT36-1 CPLT42-1 CPLT48-1 CPLT60-1 REPAIR PARTS CPLT 13 SEER Series Condensing Units OPTIONAL COMPRESSOR WARRANTY CPLT24-1 CPLT24-1A CPLT30-1 CPLT30-1A CPLT36-1 CPLT42-1 CPLT48-1 CPLT60-1 This manual is to be used by qualified technicians

More information

INSTALLATION INSTRUCTIONS ProVantage Plow Pulley Part Number: 84526

INSTALLATION INSTRUCTIONS ProVantage Plow Pulley Part Number: 84526 ProVantage Plow Pulley Part Number: 84526 GENERAL SAFETY PRECAUTIONS Your safety, and the safety of others, is very important. To help you make informed decisions about safety, we have provided installation

More information

PLOW MOUNT KIT FOR POLARIS RANGER P/N ASSEMBLY / OWNERS MANUAL

PLOW MOUNT KIT FOR POLARIS RANGER P/N ASSEMBLY / OWNERS MANUAL PLOW MOUNT KIT FOR POLARIS RANGER P/N 34-3010 ASSEMBLY / OWNERS MANUAL Application PLOW PUSH FRAME NO. 34-0000 or 34-0070 Before you begin, please read these instructions and check to be sure all parts

More information

REPAIR PARTS. *CVC9 90% C'Flow 2-Stage Variable Speed Furnace

REPAIR PARTS. *CVC9 90% C'Flow 2-Stage Variable Speed Furnace REPAIR PARTS *CVC9 90% C'Flow 2-Stage Variable Speed Furnace ACVC90704CXAA ACVC90704CXAB ACVC90905DXAA ACVC90905DXAB ACVC950714CXAA ACVC950915DXAA GCVC90704CXAA GCVC90704CXAB GCVC90905DXAA GCVC90905DXAB

More information

REPAIR PARTS. GDS8 80% Furnace GDS80453AXCA GDS80453AXCB GDS80703AXCA GDS80703AXCB GDS80904BXCA GDS80904BXCB GDS81155CXCA GDS81155CXCB

REPAIR PARTS. GDS8 80% Furnace GDS80453AXCA GDS80453AXCB GDS80703AXCA GDS80703AXCB GDS80904BXCA GDS80904BXCB GDS81155CXCA GDS81155CXCB REPAIR PARTS GDS8 80% Furnace GDS80453AXCA GDS80453AXCB GDS80703AXCA GDS80703AXCB GDS80904BXCA GDS80904BXCB GDS855CXCA GDS855CXCB This manual is to be used by qualified technicians only. This manual replaces

More information

Submittals. Advanced Series 1U09ES2VHA / AW09ES2VH* 1U12ES2VHA / AW12ES2VH* 1U18ES2VHA / AW18ES2VH* 1U24ES2VHA / AW24ES2VH* Rev.

Submittals. Advanced Series 1U09ES2VHA / AW09ES2VH* 1U12ES2VHA / AW12ES2VH* 1U18ES2VHA / AW18ES2VH* 1U24ES2VHA / AW24ES2VH* Rev. Submittals Advanced Series 1U09ES2VHA / AW09ES2VH* 1U12ES2VHA / AW12ES2VH* 1U18ES2VHA / AW18ES2VH* 1U24ES2VHA / AW24ES2VH* C US Intertek For more information visit us: www.haierductless.com www.haierductlesshelp.com

More information