Energy Efficient Easy to Install Extended Service Life. Horizontal Direct Drive Blower Coils BUILD YOUR REPUTATION ON OURS
|
|
- Duane Hunter
- 5 years ago
- Views:
Transcription
1 Energy Efficient Easy to Install Extended Service Life Energy efficient compact blower coils Ideal for educational, hospitality, multi-family, or other commercial environments Designed for ducted applications Nominal CFM range of 00 to 3,000 CFM BUILD YOUR REPUTATION ON OURS
2 Table of content Table of Contents 3 Portfolio -5 Features and Benefits -7 Unit Nomenclature Nominal Capacity and Listing 9- Cooling Capacity Tables 7-0 Heating Capacity Tables Electric Resistance Heating Motor Data 3 Component Static Resistance Sound Power Data 5- Fan Curves 9-30 Physical Data 3-3 Piping Stub-Out Location 33 Distributed Weight Calculations 3 Filters 35 Factory-Installed Options 3-37 Options - Mixing Box International Environmental Corporation (IEC) works continually to improve its products. As a result, the design and specifications of each product may be changed without notice and may not be as described herein. Please contact IEC for information regarding current design and product specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties but are merely IEC s opinion or commendation of its products. Manufacturer s standard limited warranty applies.
3 Horizontal Direct Drive Units 00 to 3000 CFM Versatile Units These compact blower coils are ideally suited for a variety of ducted applications that require a range of 00 to 3000 CFM, capacities between.5 tons to 0 tons, and generally rated for applications with w.g. or less of external static pressure, but can be operated at higher ESP - contact factory for additional information. These units provide comfort cooling and heating while offering a broad range of application flexibility between the traditional fan coil unit and a central station air handling unit. Several configurations are available to meet the needs of different climates and applications. The HDY units can be ordered as a: -pipe system -pipe system with electric heat -pipe system Direct expansion system cooling Direct expansion cooling with electric heat Direct expansion cooling with hot water heating Multitude of Applications These units are ceiling mounted, and available with a variety of options that can meet the design requirements, and provide a low cost solution for a multitude of applications. TOOL-FREE REMOVAL OF ACCESS PANELS PRIMARY AND SECONDARY DRAIN CONNECTION FROM DOUBLE-SLOPED STAINLESS STEEL DRAIN PAN ISOLATED BLOWER FOR QUIET OPERATION IMPROVED FILTER RACK DESIGN, ACCEPTS,, OR FILTERS, TOOL-FREE FILTER ACCESS FROM BOTTOM AND TWO SIDES STANDARD EC MOTOR DOUBLE SLOPED STAINLESS STEEL DRAIN PAN OPTIONAL DOUBLE WALL CONSTRUCTION 3
4 Standard Horizontal Direct Drive Blower Coil Applications Where the application calls for cooling capacities or external static pressures that can not be met with standard or high performance direct drive fan coil units; use an IEC horizontal direct drive blower coil. Outside Air Applications With the availability of larger capacities, a variety of optional coils, mixing boxes, and the capability of delivering air through long duct runs, the direct drive units are ideal for handling outside air. When used as outside air units, the heating coil should be in the pre-heat location (consult factory). Operating Limitations Fan curves define the recommended airflow and static pressure ranges of operations. Running the HDY units outside this range could lead to drastically reduced bearing life and premature wheel failure. In cooling applications, this could also result in moisture carry over. In addition, running the fan at its maximum fan speed will increase the power requirements and generate higher sound levels. On units with electric heat, the minimum airflow shown on the fan curve must be maintained to prevent excessive discharge temperature and electric heat safety trips. Large Public Areas These units are ideal for applications with a large common area such as restaurants, airports, sports arenas, stadiums, private boxes, gymnasiums, exercise areas, locker rooms, atriums and foyers, auditoriums, shopping malls, equipment or mechanical rooms, and casinos, to name a few. Installation Considerations The HDY units are typically suspended above the ceiling. Attention should be paid to having enough clearance around the units for service and maintenance. Horizontal units are generally suspended above the ceiling using hanger rods that go through the corner knock-outs provided in the units. External vibration isolation and flex connections for ducts are recommended. Acoustical Considerations With sound becoming more of a concern to design engineers, building owners, and occupants, proper consideration should be given to the selection and placement of these units. Whenever possible, avoid placing these units above an occupied space. To further reduce the sound level, additional measures such as: using flexible duct connectors; lining the main supply and return ducts with acoustical absorption material; locating the return air grilles as far away from the unit as possible; and using 3-phase motors.
5 Application Fit Horizontal configuration, with different sizes to meet a multitude of room layouts and ventilation needs Wide variety of coil options including 00% outside air applications Design Flexibility Optional double wall construction, perforated or solid lined Removable double-sloped stainless steel drain pan for ease of cleaning and better IAQ performance; all models include primary and secondary drain connections to provide back-up if the main drain is plugged Wide variety of coil sizes (,, -rows) for a better match to the heating and cooling loads of the space; coils with different materials (copper fins with stainless steel end sheets and bottom coil baffles) Standard EC Motors ranging from / to 3 HP in a variety of voltages, in both single- and 3-phase A standard filter rack allows for, or of filtration up to MERV 3 Variety of insulation materials to comply with IAQ concerns Heating provided by a hot water coil or electric heat for varying application needs and climates Mixing boxes available for outside air applications Ease of Installation Units are pre-assembled with factory installed optional electric heater controls V control eliminates the need to run control wiring in conduit Corner knock-outs for hanger rods and isolators facilitate quick and easy installation Duct collars for supply and return air Optional factory installed controls eliminate the need for motor starters Ease of Service Tool-free and easily accessible filters from multiple sides Large, tool-free access panels on both sides Optional lighting available in cabinet and control box; provides a well lit space to perform service or routine maintenance Quality and Safety Every unit tested and inspected at the factory for trouble-free startup Optional condensate float switch satisfies the latest building codes constraints Motors have built-in thermal overload protection ETL and CETL listed User-friendly Ratings program expedites the project design and equipment selection 5
6 UNIT SIZE UNIT NOMENCLATURE COIL 0 00 CFM 0 00 CFM CFM 00 CFM 00 CFM CFM 00 CFM CFM CABINET OPTIONS Drain Pan AS Double Slope Stainless Steel Filter Options A throwaway C sets of throwaway F Pleated MERV G Pleated MERV M MERV with pleated pre-filter U MERV (not available w/mixing box) W MERV 3 (not available w/mixing box) Insulation C Closed Cell W Standard Fiberglass S Premium IAQ Fiberglass (Edges Sealed) G Foil Face (Edges Sealed) C, S & G not allowable w/ Double-Wall Mixing box N Rear & Top/Bottom Return comes Standard with Single-blade Dampers Walls Construction Y A B Single-Wall (Standard) Double-Wall Construction (Solid Liner) DW Constr. (Perforated) Other Cabinet Options Rows BY KY LY B / B7 / K / K / QY row DX 0A FY Row DX 0A Q row heating (pre-heat position) and row DX 0A F row heating (pre-heat position) row DX 0A 7Q row heating (pre-heat position) row DX 0A 7F row heating (pre-heat position) row DX 0A. On size and above with row heat coil is circuit, below size coil has circuit Total rows allowed is. Hand R L Right-hand Coil Connections Left-hand Coil Connections Standing in front of the unit, hand is determined by looking into the air supply and assigning the hand to match the location of the cooling coil connections Material (Tube/Fin/Coatings) Y Aluminum Fins w/ Galvanized Wrap S Aluminum Fins w/ Stainless Steel Wrap C Copper Fins Stainless Steel Wrap Accessories - Vents/Drains Y MAV(Std) A AAV(-Pipe) B AAV(-Pipe) C MAV w/ Drain (-Pipe) D MAV w/ Drain (-Pipe) E AAV w/ Drain (-Pipe) F AAV w/ Drain (-Pipe) A Cabinet/Control Box Service Light Accessories - TXV T TXV Valve (DX Only) Y None
7 EC MOTOR Heater Stages Motor-Voltage/Phase/Hertz C 5//50-0 D 0//50-0 E 30//50-0 F 77//50-0 V 0//50 N 0/3/50-0 P 30/3/50-0 G 0/3/50-0 Y A B C D E None -Stage, Single-Phase (- kw) -Stage, Single-Phase (3- kw) -Stage, 3-Phase (-35 kw) -Stage, 3-Phase (-35 kw) 3-Stage, 3-Phase (-35 kw) Rules apply for stages CONTROLS Horsepower C / HP E HP F.5 HP (Three Phase only) H 3 HP (Three Phase only) Motor Type M EC Motor, no board (0-0 VDC) N EC Motor, POT board, 3 discrete speeds ELECTRIC HEAT Heater Voltage Y None F 77//0 C 0//0 N 0/3/0 D 0//0 P 0/3/0 E 0//0 G 0/3/0 Heater Kilowatt Y None BY.0 HY 5 NH 5 CY.5 JY NJ DY KY 7 NL EY.5 LY RY 9.9 FY 3 NY 9.9 RH 5 FA 3.5 PY SY 30 GY QY SH 35 GA.5 Note: Voltage rules required, motor & heater voltage must match. Dual power source is not available. Applications BAY BA3Y BAJ BA3J BPR BP3R BPK BPH BPL BP3K BP3H BP3L st Digit is Control Voltage (B= volt); nd Digit is Type of Control (A=Motor Controls;P=Electric Heat & Motor Controls);Third Digit is Phase (=Single Phase;3=3 Phase);th Digit is Fusing and Disconnect (Y=No Fusing or Disconnect; J=0 amp Disconnect and Appropriate Motor Fusing; R=Appropriate Motor and Heater Fusing; K=R plus 0 amp disconnect; H=R plus 0 amp disconnect; L=R plus 0 amp disconnect (All electric heat includes thermal limit switch) Special Controls O Condensate Overflow Switch Low Voltage Package V W 3-Speed Adjustable (Default) Proportional (requires 0-0 VDC controller) 7
8 AHRI Certification IEC s Horizontal Direct Drive Blower Coil units are certified in compliance with Air-Conditioning, Heating, and Refrigeration Institute (AHRI) industry standard AHRI-0 for room fan coil units. Approved standard ratings are tabulated below. Nominal Capacity Range Model Unit Size Coil Rows Nominal CFM HDY C-ETL-US Listing IEC s Direct Drive Series blower coil units are listed by Intertek Testing Services (ITS). ITS s C-ETL-US listing signifies that IEC s blower coil units have been examined by ITS and comply with the minimum requirements of U.S. and Canadian national product safety standard, UL 995/CSA C. No. 3, and that IEC s manufacturing site has been audited. ITS s re-examination service includes periodic visits to IEC s factory to ensure continued compliance for all listed products. Water Pressure Drop (ft.water) Cooling Capacity (BTUH) Total Sensible 307 HEATING AND COOLING EQUIPMENT Power Input (Watts) ,900 3, ,000, ,000, ,900 7, ,000 0, ,00, , ,700 3,00 0 0, ,500 5, , ,00 7,500 0, ,00,00 335,00.7 7,00 30, , ,000 3,00 30,00.7 9,000 35,300 0,00 0.0,500 39,700 0,00. 7,00, , ,00 5, ,000. 7,000 5, , ,00 55,00 50,00.0 5,000 7,00 575, ,00 5,900 00, ,500 59, ,000. 9,500 7, , ,900 0, ,000.,000, NOTES:. Ratings are based on 0 F (.7 C) DB and 7 F (9. C) WB EAT, 5 F (7. C) EWT, 0 F Δ(5. C Δ) water temperature rise, high fan speed, motor voltage 5//0, and airflow under dry coil conditions.. For all application ratings, use IEC s computer selection program, the quick-selection ratings provided in this catalog, or contact your local IEC representative. 3. For additional information, please consult AHRI s website at
9 Cooling Capacity Unit Size CFM Rows 0 (/) HP EAT ( F) DB/WB EWT ( F) ΔT Total Sensible WPD GPM ( F) (MBH) (MBH) (ft. wg.) NOTE: Ratings are based on 0 F (.7 C) DB and 7 F (9. C) WB EAT, or 75 F ( 3.9 C) DB and 3 F (7. C) WB; 5 F (7. C) EWT, 0 F Δ (5. C Δ) or F Δ (.7 C Δ) water temperature rise. 9
10 Cooling Capacity, Cont d. Unit Size CFM Rows 0 ( HP) EAT ( F) DB/WB EWT ( F) ΔT Total Sensible WPD GPM ( F) (MBH) (MBH) (ft. wg.) NOTE: Ratings are based on 0 F (.7 C) DB and 7 F (9. C) WB EAT, or 75 F ( 3.9 C) DB and 3 F (7. C) WB; 5 F (7. C) EWT, 0 F Δ (5. C Δ) or F Δ (.7 C Δ) water temperature rise. 0 0
11 Cooling Capacity, Cont d. Unit Size CFM Rows 0 (/ HP) EAT ( F) DB/WB EWT ( F) ΔT Total Sensible WPD GPM ( F) (MBH) (MBH) (ft. wg.) NOTE: Ratings are based on 0 F (.7 C) DB and 7 F (9. C) WB EAT, or 75 F ( 3.9 C) DB and 3 F (7. C) WB; 5 F (7. C) EWT, 0 F Δ (5. C Δ) or F Δ (.7 C Δ) water temperature rise.
12 Cooling Capacity, Cont d. Unit Size CFM Rows ( HP) EAT ( F) DB/WB EWT ( F) ΔT Total Sensible WPD GPM ( F) (MBH) (MBH) (ft. wg.) NOTE: Ratings are based on 0 F (.7 C) DB and 7 F (9. C) WB EAT, or 75 F ( 3.9 C) DB and 3 F (7. C) WB; 5 F (7. C) EWT, 0 F Δ (5. C Δ) or F Δ (.7 C Δ) water temperature rise.
13 Cooling Capacity, Cont d. Unit Size CFM Rows ( HP) EAT ( F) DB/WB EWT ( F) ΔT Total Sensible WPD GPM ( F) (MBH) (MBH) (ft. wg.) NOTE: Ratings are based on 0 F (.7 C) DB and 7 F (9. C) WB EAT, or 75 F ( 3.9 C) DB and 3 F (7. C) WB; 5 F (7. C) EWT, 0 F Δ (5. C Δ) or F Δ (.7 C Δ) water temperature rise. 3
14 Cooling Capacity, Cont d. Unit Size CFM Rows 0 ( HP) EAT ( F) DB/WB EWT ( F) ΔT Total Sensible WPD GPM ( F) (MBH) (MBH) (ft. wg.) NOTE: Ratings are based on 0 F (.7 C) DB and 7 F (9. C) WB EAT, or 75 F ( 3.9 C) DB and 3 F (7. C) WB; 5 F (7. C) EWT, 0 F Δ (5. C Δ) or F Δ (.7 C Δ) water temperature rise.
15 Cooling Capacity, Cont d. Unit Size CFM Rows ( / HP) EAT ( F) DB/WB EWT ( F) ΔT Total Sensible WPD GPM ( F) (MBH) (MBH) (ft. wg.) NOTE: Ratings are based on 0 F (.7 C) DB and 7 F (9. C) WB EAT, or 75 F ( 3.9 C) DB and 3 F (7. C) WB; 5 F (7. C) EWT, 0 F Δ (5. C Δ) or F Δ (.7 C Δ) water temperature rise. 5
16 Cooling Capacity, Cont d. Unit Size CFM Rows 30 (3 HP) EAT ( F) DB/WB EWT ( F) ΔT Total Sensible WPD GPM ( F) (MBH) (MBH) (ft. wg.) NOTE: Ratings are based on 0 F (.7 C) DB and 7 F (9. C) WB EAT, or 75 F ( 3.9 C) DB and 3 F (7. C) WB; 5 F (7. C) EWT, 0 F Δ (5. C Δ) or F Δ (.7 C Δ) water temperature rise.
17 Heating Capacity Unit Size CFM Rows 0 (/ HP) 0 ( HP) EWT ( F) ΔT LAT WPD MBH GPM ( F) ( F) (ft. wg.) NOTES:. Based on 70 F (. C) entering air temperature.. For leaving air temperature above 30 F (5. C) consult the factory. 7
18 Heating Capacity, Cont d. Unit Size CFM Rows 0 (/ HP) ( HP) EWT ( F) ΔT LAT WPD MBH GPM ( F) ( F) (ft. wg.) NOTES:. Based on 70 F (. C) entering air temperature.. For leaving air temperature above 30 F (5. C) consult the factory.
19 Heating Capacity, Cont d. Unit Size CFM Rows ( HP) 0 ( HP) EWT ( F) NOTES:. Based on 70 F (. C) entering air temperature.. For leaving air temperature above 30 F (5. C) consult the factory. ΔT LAT WPD MBH GPM ( F) ( F) (ft. wg.)
20 Heating Capacity, Cont d. Unit Size CFM Rows ( / HP) 30 (3 HP) EWT ( F) NOTES:. Based on 70 F (. C) entering air temperature.. For leaving air temperature above 30 F (5. C) consult the factory. ΔT LAT WPD MBH GPM ( F) ( F) (ft. wg.)
21 Electric heaters are available on IEC Direct Drive blower coils for total electric heat. Total Electric Heat Total electric heat eliminates the requirement for a boiler and provides heating and/or cooling on an individual basis throughout the year. Electric heat is available only for single source power (motor and heater voltage the same). Heater Construction The heater coils of high-grade resistance wire are supported by ceramic insulators on plated steel brackets. These heat elements are suspended directly in front of the outlet after the blower and the coil. An auto and a manual thermal limit switch protect the heater in the event of airflow failure. For electric heat control options refer to page 35. Electric Heater Selection kw Heater Availability Full Load Amps Single Phase Three Phase 0 0/ 30 5 V 0 V 30 V 77 V 0 V 30 V 0 V NOTES:. Electric heaters are available for -stage, -stage or 3-stage applications depending on power phase and heater kw. SINGLE-PHASE POWER: - kw: -stage available 3- kw: -stage available 3-PHASE POWER: -35 kw: -stage available -35 kw: -stage available -35 kw: 3-stage available. Electric Heating Capacities (BTUH) = Heater kw x Electric Heater Amperage for Single-phase Power = (Heater kw x 000)/Applied Voltage Electric Heater Amperage for 3-phase Power = (Heater kw x 000)/(Applied Voltage x.73)
22 Thermal Overload Protection All standard motors on Horizontal Direct Drive units furnished by IEC contain internal thermal overload protection. The overload automatically resets when the temperature returns to a safe limit. These thermal overloads replace the need for motor starters. Motor Full Load Amps Data HDY Voltage 5 V 50/0 Hz -Phase 0 V 50/0 Hz -Phase 30 V 50/0 Hz -Phase 77 V 50/0 Hz -Phase 0 V 50/0 Hz 3-Phase 30 V 50/0 Hz 3-Phase 0 V 50/0 Hz 3-Phase UNIT SIZE 0, 0 0,,,0 30 Motor HP / -/ NA NA 3..3 NA NA NA NA NA NA NOTES:. Motor full load Amps refer to National Electric Code (NEC) Amps; actual motor nameplate amps may vary.. Motors are UL recognized constant speed brushless DC, open drip proof, ball bearing, multi-input voltage options, 0-0 VDC control, PWM control and VDC supply direct from motor. / and HP motors have integrated control module with overload and short circuit protection. -/ and 3 HP motors have remote mounted control with overload and short circuit protection. Control module is mounted internal of cabinet.
23 Component Static Resistance Table (in w.c.) Unit Size Nominal CFM Row Coil(includes cabinet) Dry 5 Row Row 7 Row Row Throwaway " MERV Pleated (Qty. ) " Throwaway Filters " MERV Pleated " MERV w/prefilter MERV Pleated MERV 3 Pleated Mixing Box
24 Sound Power Data UNIT SIZE RATING FAN SPEED CFM SOUND POWER LEVEL, Lw (db reference one picowatt) 5 Hz 50 Hz 500 Hz K Hz K Hz K Hz K Hz A-wgt (dba) Motor HP CASING RADIATED NOTE DUCTED DISCHARGE NOTE ESP / CASING RADIATED NOTE DUCTED DISCHARGE NOTE 3,075 ESP CASING RADIATED NOTE DUCTED DISCHARGE NOTE ESP / CASING RADIATED NOTE DUCTED DISCHARGE NOTE 3,35,00@.50 ESP CASING RADIATED NOTE DUCTED DISCHARGE NOTE 3,0,00@.50 ESP CASING RADIATED NOTE DUCTED DISCHARGE NOTE 3 90,000@.50 ESP NOTE CASING RADIATED NOTE DUCTED DISCHARGE NOTE 3 950,00@.50 ESP / 30 NOTE CASING RADIATED NOTE DUCTED DISCHARGE NOTE 3 0 3,000@.50 ESP NOTES:. Unit Test Configuration: Rear Return/Front Supply, Row, 0 FPI Coil, 5/ PH/ 0HZ VAC Motor, Fiberglass Filter, / dual density fiberglass insulation.. Testing per AHRI 0-00:...3 Casing radiated with free inlet, Sound Rating of Ducted Air Moving and Conditioning Equipment. 3. Testing per AHRI 0-00:... Ducted discharge, Sound Rating of Ducted Air Moving and Conditioning Equipment.. Size & 30 Unit Test Configuration: Rear Return/Front Supply, Row, 0 FPI Coil, 0/3 PH/ 0HZ VAC Motor, Fiberglass Filter, / dual density fiberglass insulation. 5. Sound power data is expressed in decibels, db RE: x 0- w (picowatts). 3
25 Fan Curves.5 HDY0, / hp Motor.75.5 TOTAL STATIC PRESSURE RECOMMENDED OPERATING RANGE SCFM RPM HDY0, hp Motor TOTAL STATIC PRESSURE RECOMMENDED OPERATING RANGE SCFM RPM
26 Fan Curves, Cont d..5 HDY0, / hp Motor.5 TOTAL STATIC PRESSURE RECOMMENDED OPERATING RANGE SCFM RPM HDY, hp Motor.5 TOTAL STATIC PRESSURE RECOMMENDED OPERATING RANGE SCFM RPM
27 Fan Curves, Cont d. 3 HDY, hp Motor TOTAL STATIC PRESSURE RECOMMENDED OPERATING RANGE SCFM RPM HDY0, hp Motor TOTAL STATIC PRESSURE RECOMMENDED OPERATING RANGE SCFM RPM
28 Fan Curves, Cont d. 3 HDY,.5 hp Motor TOTAL STATIC PRESSURE RECOMMENDED OPERATING RANGE SCFM RPM HDY30, 3 hp Motor TOTAL STATIC PRESSURE RECOMMENDED OPERATING RANGE SCFM RPM
29 HDY Unit Horizontal Direct Drive Drawing is not to scale and is provided for reference only. Dimensions may vary with options ordered. Consult IEC website for up-to-date drawings. Size Fan Size Depth Width Height Supply Duct Return Duct (Note 7) Mounting Holes Aux.Ctrl. Box A B C D E F G J K L -7/ 0-7/ 3-3/ -/ -/ -3/ 7-/ 35-/ 5-3/ (5) (7) (39) (57) () (35) (70) () (95) () -7/ 0-7/ 3-3/ -/ -/ -3/ 7-/ 35-/ 5-3/ (5) (7) (39) (57) () (35) (70) () (95) () -7/ 0-7/ -/ -/ 33-/ 5-3/ -7/ 3-/ 37 5 (5) (7) (3) (57) (5) (0) (73) (9) (90) () -7/ 0-7/ -/ -/ 33-/ 5-3/ -7/ 3-/ 37 5 (5) (7) (3) (57) (5) (0) (73) (9) (90) () 0-3/ -3/ -/ 3-7/ 5-3/ -7/ -/ 37 -/ () (305) (7) (57) (5) (0) (73) (75) (90) (3) 3-7/ 3 7-/ -/ -/ -7/ 7-/ 39-/ -3/ (35) (330) (3) (57) () (57) (73) (00) (033) (0) -/ 7-/ -/ -/ -/ 7-/ 39-/ 3-3/ (3) (35) (0) () () (73) (3) (00) (033) (95) 0 9 x 3 9-3/ (9) (7) (50) 0 9 x 3 9-3/ (9) (7) (50) 0 9 x 37-/ 37 -/ (953) (90) (5) 9 x 37-/ 37 -/ (953) (90) (5) 0 x / 7 -/ (959) (9) (5) 0/ x 0 0-/ (0) (9) (0) 30 x 0-/ 3-/ (0) (9) (9) NOTES:. RH shown, LH opposite.. All dimensions are +/- /" ( mm). 3. Product specifications are subject to changes without notice.. Dimensions in parenthesis are shown in (millimeters). 5. Allow adequate spacing or maneuverability around unit to allow service through recommended access area.. C dimension is measured from coil side of unit. 7. Mixing Box option will vary return duct dimensions, refer to mixing box submittal. 9
30 HDY Unit with Optional Mixing Box Drawing is not to scale and is provided for reference only. Dimensions may vary with options ordered. Consult IEC website for up-to-date drawings. Size Mounting Fan Unit Depth Size Depth Width Height Supply Duct Return Duct (Note 7) Mix Box Aux.Box Holes A B C D E F G H J K L 0 9 x 5-5/ 3-3/ -7/ 0-7/ 3-3/ -/ -/ 7-/ 35-/ 5-3/ (3) (9) (7) (57) (5) (7) (39) (57) (0) (5) (3) (79) () (95) () 0 9 x 5-5/ 3-3/ -7/ 0-7/ 3-3/ -/ -/ 7-/ 35-/ 5-3/ (3) (9) (7) (57) (5) (7) (39) (57) (0) (5) (3) (79) () (95) () 0 9 x 55-/ 37-/ 37 -/ -7/ 0-7/ -/ -/ 33 -/ 3 3-/ 37 5 (0) (953) (90) () (5) (7) (3) (57) (3) (03) (3) (330) (9) (90) () 9 x 55-/ 37-/ 37 -/ -7/ 0-7/ -/ -/ 33 -/ 3 3-/ 37 5 (0) (953) (90) () (5) (7) (3) (57) (3) (03) (3) (330) (9) (90) () 0 x / 37-3/ 7 -/ 0-3/ -3/ -/ 3 -/ 3 -/ 37 -/ (7) (959) (9) () () (305) (7) (57) (09) (03) (3) (330) (75) (90) (3) 0/ x / 0-/ 7 3-7/ 3 7-/ -/ -3/ 3 7-/ 39-/ -3/ (7) (0) (9) () (35) (330) (3) (57) () (03) (5) (330) (00) (033) (0) 30 x 59-3/ 0-/ 35-/ -/ 7-/ / 39-/ 3-3/ (5) (0) (9) (95) (3) (35) (0) () () (5) (3) (3) (00) (033) (95) NOTES:.RH shown, LH opposite. 0. Add (5) if using a Prefilter, or (0) filter.. All dimensions are +/- / ( mm). 3. Product specifications are subject to changes without notice.. Dimensions in parenthesis are shown in (millimeters). 5. Allow adequate spacing or maneuverability around unit to allow service through recommended access area.. C dimension is measured from coil side of unit. 7. Mixing Box option will vary return duct dimensions, refer to mixing box submittal.. Mixing Box options include: a) Knockdown base rails for field assembly; b) Pre-assembled Mixing Box. 9. Linkage kit supplied with Mixing Box is provided for field installation of actuator
31 Piping Connection Location (Centerline to Centerline) Hydronic Cooling and Heating Coils D C CR - Cold Water Return HR - Hot Water Return CS - Cold Water Supply HS - Hot Water Supply RH - Right Hand LH - Left Hand B A (5) -5/() 0 Coil Header Connection Size Row Row Row Row HW Row HW Unit Size Nom. Actual Nom. Actual Nom. Actual Nom. Actual Nom. Actual Size OD Size OD Size OD Size OD Size OD / / 0.75 / 0.5 / / /.5 -/.5 -/.5 -/.5 -/.5 0 -/() -7/(75) G -5/(9) F 0-3/() E Horizontal, left hand unit with re-heat coil shown. Unit Size 0/0 0/ 0/ 30 Coil Rows Cool Heat A B C D E F G 3-/ 5-/ / 3-3/ 5-3/ 7-9/ 7-9/ -/ -3/ 3-/ 5-/ 9-3/ 9-3/ -/ 3-3/ 5-3/ 9-3/ 9-3/ 0-/ 5-/ 7-/ / 5-7/ 7-7/ 7-9/ 7-9/ 7-3/ -3/ 5-/ 7-/ 9-3/ 9-3/ -/ 5-7/ 7-7/ 9-3/ 9-3/ 0-/ 7-3/ LH 0-5/ 5-5/ 9-5/ 7 7-3/ RH 3-3/ 9-5/ 7 5-5/ 7-3/ 3-5/ 0-3/ 7-9/ 7-3/ LH 0-5/ 5-5/ -3/ 9-3/ 7-3/ RH 3-3/ -3/ 9-3/ -/ 7-3/ 3-5/ -/ 9-3/ 9-/ 5-5/ 0-/ 7-3/ LH -5/ 5-5/ 7-3/ 3-5/ 9-5/ RH -/ 7-9/ 7-7/ 5-3/ 9-/ 5 7-3/ -3/ LH -5/ -/ 7-3/ 3-5/ -3/ RH -/ 9-3/ -9/ 7-7/ 5-3/ -/ 7-/ 7-3/ 0-/ 5-5/ 7-/ 5-3/ 9 0-5/ 3-3/ 9-/ 7-7/ 5-5/ -5/ -/ 7-/ 5-3/ -/ 0-5/ 3-3/ -5/ 9-/ 7-/ 0-/ 3
32 Piping Connection Location (Centerline to Centerline) R-0A Cooling with Hot Water Heating D HR - Hot Water Return HS - Hot Water Supply LL - Liquid Line SL - Suction Line C B A (5) -5/() 0 Coil Header Connection Size (Nominal OD in Inches) LL SL Row HW Row HW Unit Size Nom. Actual Nom. Actual Nom. Actual Nom. Actual Size OD Size OD Size OD Size OD 0- / / 0.75 / 0.5 / / / / 0.5 -/.5 -/.5 -/.5 0 H G 7/(75) 5/(9) F E Horizontal, left hand unit with pre-heat coil shown. SIZE 0/0 0/ 0/ 30 COIL ROWS DX ONLY WATER A B C D E F G PRE-HEAT H -3/ -3/ 5-/ -/ 3-3/ -5/ -5/ -7/ 3-/ 3-/ -3/ -/ 7-/ -/ 3-3/ -5/ -5/ 5-/ 7-/ -7/ 3-/ 3-/ -3/ 7-/ -/ 5-/ 7-/ -/ 3-3/ -5/ -5/ -3/ 0 3-5/ -/ -/ -5/ -3/ -/ 7-/ 5-/ 9-3/ -/ 3-3/ -5/ -5/ -3/ 7-/ -5/ 5-7/ -3/ -/ -5/ -5/ 5-3/ -3/ -/ 5-7/ -/ -/ -7/ 5-3/ 0-3/ 3-7/ -3/ -/ -5/ 3 3
33 Distributed Weight Calculations The following operating weight information is based on -row water-filled coils and double wall cabinet construction. For a different coil and cabinet options, use the weight correction factor table. Horizontal Units (Top View) HDY Unit No Electric Heat (lb.) With Electric Heat (lb.) A B C D Total A B C D Total Total Weight Unit Correction Factor (lb.) HDY These weights are for -row water-filled coils and double wall construction. For a different number of rows, total unit weight can be determined by: Total unit weight can be adjusted by : a. Identify the size of unit and number of rows b. From the previous table, identify the total weight of the unit c. From the table below, identify the correction factor and deduct this factor from the total weight. Options Row Coil Row Coil Row Coil Row Coil Single Wall Construction NOTE:. Unit weights (shown in pounds), +/- 0 percent, are based on the largest water-filled coil. 33
34 Filters The standard Direct Drive Blower Coils are furnished with a set of pleated MERV filters. Unit Size Filter Quantity Nominal Filter Sizes Inches (Millimeters) HDY 0 -/" x " (9 x 0) 0 -/" x " (9 x 0) 0 -/" x 33" ( x 3) -/" x 33" ( x 3) -/" x -/" ( x 5) 0/ 0-/ x " (5 x 559) 30 9" x " (737 x 559) Side and bottom filter removal No tools needed for easy filter change, usage of strong magnets in place of hardware Choice of, or filters Easy to modify in the field for either, or filters Robust design eliminates unit s sagging Filter See Detail X Filter Magnet Detail X Filter 3 3
35 Factory Installed Options Controls: Motor Controls Units without electric heat: Two controls schemes are available: 3 - Speed adjustable. Proportional (0-0 VDC). Electric Heat Controls Electric heaters come standard with a transformer, heater contactors, motor and electric heat fusing, and a terminal strip. Condensate Float Switch A water-level sensing device designed to prevent drain pan overflow. The standard switch is wired normally closed. Switches are available only in V. Cabinet/Control Box Maintenance Light Optional LED Service Light provides a source of illumination in the main unit cabinet and the control box during routine maintenance and troubleshooting in the dark ceiling spaces. An optional interlocking disconnect switch is available. Control Box Above picture is the example of Control box with electric heat, disconnect switch and service light. 35
36 Mixing Boxes Mixing boxes can be used when outside air is required. Mixing boxes come with base rails. Refer to the drawings on pages 3 and 37 for additional information. Mixing Box with Base Rails Mixing box option includes :.) knockdown base rails for field assembly, and.) pre-assembled mixing box. Base rails are letter coded for ease of assembly and all hardware required for assembly is included. Linkage kit consists of crank arms, swivels, and either a 5" (sizes 0-) or a 3" (sizes 0-30) length of 5/" rod provided for field installation of actuator. Consult factory for the V damper actuator option. Mixing box option adds 3" to the unit height due to the base rails. Base Rail Details (5) A W FRONT VIEW (5) D SIDE VIEW 3(7) Horizontal Units Dimensions - Inches (Millimeters) Unit Type and Size W D A HDY0 (7) 5. (3). (09) HDY0 (7) 5. (3). (09) HDY0 37 (90) 55. (). (0) HDY 37 (90) 55. (). (0) HDY 7 (9) 55. (7). (0) HDY0/ (9) 57. (). (0) HDY30 (9) 59. (59) 0. (5) 3 3
37 Mixing Box Details B W B W (5) (5) TOP VIEWS (5) A (0) 3(7).() A H.().() A H.() 3(7) A (0) (5) C BTM/REAR INLET - HDY C TOP/REAR INLET - HDY RIGHT HAND SIDE VIEWS Dimensions - Inches (Millimeters) Unit Size H W A B C 0.5 (70) (7) (5) (0) (79) 0.5 (70) (7) (5) (0) (79) (5) 37 (90) (03) 33 (3) 3 (330) 0.5 (5) 37 (90) (03) 33 (3) 3 (330) 0.5 (5) 7 (9) (03) 3 (09) 3 (330) 0/.75 (57) (9) (03) () 3 (330) 30 3 (77) (9) 0 (5) () 5 (3) Note: Add (5) to total unit length if using prefilter or filter with mixing box option. 37
38 3 3
39 39
40 Contact your local IEC Sales Representative for further details and pricing applicable to this product. Visit our website (iec-okc.com) to find your local IEC Sales Rep. IEC Catalog Part #: I CA-090(/0) 0 International Environmental Corporation (IEC) PO Box 59 Oklahoma City, OK P: F:
BV SERIES. VERTICAL BLOWER COIL UNITS Nominal Sizes 2 thru 10 Ton
BV SERIES VERTICAL BLOWER COIL UNITS Nominal Sizes 2 thru 10 Ton MAGIC AIRE BV SERIES FAN COILS ARE ETL LISTED TO U.S. AND CANADIAN SAFETY STANDARDS AND ARE ASSEMBLED TO ORDER FOR COMPETITIVE DELIVERY.
More informationB6VMAX Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS
TECHNICAL SPECIFICATIONS B6VMAX Series Air Handler with TXV 13-19 SEER Residential System 18,000-60,000 Btuh (Heat Pump & Air Conditioner) R-410A Refrigerant The B6VMAX Series of air handlers, when combined
More informationASPT Series. Multi-Position, Internal TXV. Air Handler 1½ to 5 Tons
Series Multi-Position, Internal TXV Product Features Internal factory-installed thermal expansion valves for cooling and heat pump applications Direct drive, multi-speed ECM blower motor All-aluminum evaporator
More informationGB5BM Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Air Handler WARRANTY
TECHNICAL SPECIFICATIONS GB5BM Series Air Handler 13 SEER Residential System 18,000-60,000 Btuh (Heat Pump & Air Conditioner) The GB5BM Series of air handlers, when combined with our heat pump or air conditioner,
More informationEND4X, ENW4X, ENA4X. Product Specifications VERTICAL EVAPORATOR COILS ALL N COIL MODELS CASED N COILS UNCASED N COILS ENA4X WARRANTY*
ENVIRONMENTALLY SOUND REFRIGERANT VERTICAL EVAPORATOR COILS ALL N COIL MODELS 1½ thru 5 Tons Available for environmentally sound R 410A systems Copper tube / aluminum fin N coil with latest high tech fin
More informationENH4X. Product Specifications HORIZONTAL EVAPORATOR COILS ALL CASED N COIL MODELS WARRANTY*
ENVIRONMENTALLY SOUND REFRIGERANT ENH4X Product Specifications HORIZONTAL EVAPORATOR COILS ALL CASED N COIL MODELS 2 thru 5 Tons Available for environmentally sound R 410A systems Copper tube / aluminum
More informationR- 410A R-22 Size (tons) Shipping Weight (lbs) WLAU184AA 1-1/ WLAU182AA 1-1/ WLAU244AA. Model /2
EVAPORATOR COILS A COIL - UNCASED R- 410A or R- 22 SYSTEMS 1 1/2 5 Tons WLAU Use of the AHRI Certified TM Mark indicates a manufacturer s participation in the program. For verification of certification
More informationModel 33SZ Basic Unit OPTIONAL FILTER RH COIL CONNECTION PRIMARY/ DEDICATED OUTDOOR AIR MULTI-POINT FLOW SENSOR 5 3/4" (146)
DESRIPTION: Sensible cooling coil on the induced air inlet handles zone sensible load. Opposite side to controls location. luminum ripple fins (10 PI) and 1/" (13) copper tubes. and of coil connection
More information10-year industry best core warranty. 2-year warranty on balance of unit.
MODEL FEATURES MERV-8 filters Fully insulated case Large cores for high efficiency No condensate pan or drain required AHRI Certified Rainhood included Access door for easy maintenance and Cleaning Integral
More informationProduct Data. CAPVU Evaporator Coil A Coil --- Uncased Upflow, Downflow CAPVU
CAPVU Evaporator Coil A Coil --- Uncased Upflow, Downflow Product Data CAPVU A06002 The CAPVU evaporator coils incorporate proven standards for reliable system operation and performance throughout the
More informationProduct Data. CNPVP, CNRVP, CNPVT, CNRVT, CNPVU, CNRVU Evaporator Coil N Coil Cased and Uncased Upflow, Downflow
CNPVP, CNRVP, CNPVT, CNRVT, CNPVU, CNRVU Evaporator Coil N Coil Cased and Uncased Upflow, Downflow Product Data CN(P,R)VP CN(P,R)VT (Transition) A06008 A06007 This vertical design N -coil is a furnace
More informationTHE ENERGY 68,SAVING TDVI. exible Combine Modular 24, 26, 28, 30, 32, 34, 36, 38, 40, 42, 44 HP 60, 62, 64, 66 HP
I N V E RT E R ion Range exible Combine Modular TDV I TDV I TDV I INVERTER INVERTER INVERTER 14, 16, 18, 20, 22 HP TDV I 24, 26, 28, 30, 32, 34, 36, 38, 40, 42, 44 HP INVERTER INVERTER INVERTER TDV I INVERTER
More informationSinger. Incremental Comfort Systems. K, EK Vintage F. Last Manufactured: Replacement Parts List No Revision C 04/2012
Replacement Parts List No. 055231000 Revision C 04/2012 Singer Incremental Comfort Systems K, EK 07-15 Vintage F Last Manufactured: 1976 To find your Daikin Applied parts distributor, call 1-800-377-2787
More informationMcQuay. Water Source Heat Pump. VF, VG, VP Vintage E, F, G. Last Manufactured: Replacement Parts List No Revision B 02/2017
Replacement s List No. 055206700 Revision B 02/2017 McQuay Water Source Heat Pump VF, VG, VP 240-390 Vintage E, F, G Last Manufactured: 1992 To find your Daikin Applied parts distributor, call 1-800-377-2787
More informationProduct Data. CNPHP, CNRHP Evaporator Coil N Coil --- Cased Horizontal CNPHP / CNRHP
CNPHP, CNRHP Evaporator Coil N Coil --- Cased Horizontal Product Data 06005 This horizontal design N -coil is an evaporator coil designed to provide the highest standards of reliability and durability.
More informationENVIRONMENTALLY SOUND R 410A REFRIGERANT
ENVIRONMENTALLY SOUND REFRIGERANT N4H3 Performance Series Product Specifications EFFICIENT 13 SEER HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase,
More informationGMVC8. ComfortNet -Compatible. Heating Input: 70, ,000 BTU/h. Two-Stage, Variable-Speed Gas Furnace
80% AFUE Heating Input: 70,000 115,000 BTU/h ComfortNet -Compatible Two-Stage, Variable-Speed Gas Furnace Standard Features Aluminized steel, dual-diameter tubular heat exchanger Two-stage gas valve operates
More information3 Port, 2-Ton Outdoor Heat Pump
Job Name: Tag# Submittal Data Sheet 3 Port, 2-Ton Outdoor Heat Pump 3MXS24NMVJU Efficiency SEER EER HSPF Non-Ducted 17.9 12.7 12.5 Ducted 14 9.7 8.2 Mixed 15.95 11.2 10.35 Performance Cooling (Btu/hr)
More informationMcQuay Climate Control Singer. Incremental. NE, NH, NR Vintages C, D. TYA, TAA Vintages A, B. Last Manufactured: 1999
Replacement Parts List No. 055233900 Revision D 08/2017 McQuay Climate Control Singer Incremental NE, NH, NR 07-18 Vintages C, D TYA, TAA 007-015 Vintages A, B Last Manufactured: 1999 To find your Daikin
More informationASPT Series. Multi-Position, Internal TXV. Air Handler 1½ to 5 Tons
Series Multi-Position, Internal TXV Multi-Speed ECM Based Air Handler ½ to Tons Contents Air Handler Nomenclature... Heater Kit Nomenclature... Product Specifications... Dimensions... Airflow Data... Heat
More informationEFFICIENT 13 SEER HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz
ENVIRONMENTALLY SOUND REFRIGERANT N4H3 Performance Series Product Specifications EFFICIENT 13 SEER HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase,
More information4HP13 PRODUCT SPECIFICATIONS 13 SEER SPLIT SYSTEM HEAT PUMP WARRANTY
4HP13 PRODUCT SPECIFICATIONS 13 S SPLIT SYSTEM HEAT PUMP FORM NO. 4HP13-100 (07/2014) R410A Refrigerant High-quality condenser coil with copper tubing and enhanced louvered fin for maximum heat transfer
More informationVK2 volume flow controller Overview
New option with sound attenuator Maintenance-free VK2 volume flow controller that operates without an auxiliary power supply, for ventilation and air conditioning systems. Adjustable on site. Outstanding
More informationEUROVENT 8/12 SOUND TEST METHOD FOR DUCTED FAN COIL UNITS. FCP 2008 testing procedures FCP acoustical test method pag. 1
EUROVENT 8/12 SOUND TEST METHOD FOR DUCTED FAN COIL UNITS FCP 2008 testing procedures FCP acoustical test method pag. 1 CONTENTS 1 - PURPOSE... 3 2 - NORMATIVE REFERENCES... 3 3 - DEFINITIONS... 3 3.1
More information42C/V. Fan Coil Unit 42C/V
2/V Fan oil Unit 2/V arrier makes the world a better place to live by creating a comfortable, productive and healthy environment regardless of climate. It is our mission is to be customer s first choice
More informationProduct Data CNPVP, CNPVT, CNPVU, CNRVU EVAPORATOR COIL N COIL - CASED AND UNCASED UPFLOW, DOWNFLOW
CNPVP, CNPVT, CNPVU, CNRVU EVPORTOR COIL N COIL - CSED ND UNCSED UPFLOW, DOWNFLOW Product Data CNPVP CNPVT (Transition) CN(P,R)VU 06008 06007 06004 This vertical design N -coil is a furnace coil designed
More informationWater terminal control solutions
Water Terminal Control Solutions Water terminal control solutions Carrier offers a wide range of fan coil units designed to meet the needs of different systems and applications: from cabinet units in the
More informationFlexitest Switch Assemblies Type FT-19R and FT-19RX Supersedes DB March 2008
Flexitest Switch Assemblies Type FT-19R and FT-19RX Supersedes DB41-078 March 2008 FT-19R and FT-19RX FT-19R 3RU with Individual Clear Covers APPLICATION FEATURES The type FT-19R (standard length) and
More informationBETA Protecting. Low-Voltage Fuse Systems. LV HRC fuse links. 3/36 Siemens ET B1 2008
LV HRC fuse links Overview LV HRC fuses are used for installation systems in non-residential, commercial and industrial buildings as well as in switchboards of power supply companies. They therefore protect
More informationMODEL: WB009GMFI19HLD (120V) Wall Mount DC Inverter Fan Coil Unit 9,000 BTUH
MODEL: WB009GMFI19HLD (120V) Wall Mount DC Inverter Fan Coil Unit 9,000 BTUH No. Part Name Quantity BOM code List Price Remark 1 Panel assembly 1 201132890609 2 Air filter 2 201132890704 5 Display box
More informationMcQuay Climate Control Singer
Replacement Parts List No. 055204800 Revision B 01/2017 McQuay Climate Control Singer Vertical Water Source Heat Pump FC, FG, FW 240, 330, 400, 500 Vintages C, D Last Manufactured: 1986 To find your Daikin
More informationVRF Technical Data Book
VRF Technical Data Book DVM S for Euro_ET (R4A, Hz, HP) Model : Premium (Compact / Energy Efficiency) Type Standard Type History Version Modification Date Remark Ver. 1. Release DVM S (R4A, Hz, HP) for
More informationAddendum to ARI Standard , Air Terminals September 2002
Addendum to ARI Standard 880-98, Air Terminals September 2002 The September 2002 Addendum to ARI Standard 880-98, Air Terminals, is comprised of only the shaded portions shown, which has been incorporated
More information400 Volts, 50HZ 480 Volts, 60HZ 600 Volts, 60HZ TECHNICAL REFERENCE MANUAL
400 Volts, 50HZ 480 Volts, 60HZ 600 Volts, 60HZ TECHNICAL REFERENCE MANUAL FORM: MAP-TRM-E REL. July 2013 REV. 015 2013 MTE Corporation IMPORTANT USER INFORMATION NOTICE The MTE Corporation Matrix AP Harmonic
More information5SJ4...-.HG Circuit Breakers to IEC and UL 489
Siemens AG 009 5SJ...-.HG Circuit Breakers to IEC and UL 89 BETA Low-Voltage Circuit Protection Compliance with industry standards is a must in today's manufacturing environment. Worldwide acceptance is
More informationPanel Mount, Single Phase 120 and 240 Volt Fixed Shaft (click blue text for more details)
Staco Energy Products Co. has been a leading manufacturer of variable transformers for over 60 years, building standard as well as custom-designed products for industrial, commercial and military applications.
More informationPARTS LIST WATER SOURCE HEAT PUMPS HLH/HLV
PARTS LIST WATER SOURCE HEAT PUMPS HLH/HLV 1900 Wellworth Ave. Jackson, MI 49203 www.heatcontroller.com 517-787-2100 HLH PARTS LIST 072 096 120 Part # Item Description 3 3 3 3 3 3 3 3 Compressors 68832733
More informationClimateMaster s Tranquility 22. Raj Hiremath Director of Residential Marketing
ClimateMaster s Tranquility 22 Raj Hiremath Director of Residential Marketing 1 CLIMATEMASTER Industry leader since 1950 s First to introduce 2-stage 27 EER unit First to introduce Outdoor split system
More informationSECTION 1 - WHAT IS A BTU METER? BTU's = Flow x ΔT Any ISTEC BTU Meter System consists of the following main components:
SECTION 1 - WHAT IS A BTU METER? ISTEC BTU Meters measure energy usage by multiplying flow rate and temperature difference. As the water (or other liquid) passes through these lines, the multi-wing turbine
More informationREPAIR PARTS. GPH14 H-SERIES R-410A Package Heat Pumps GPH1424H41AA GPH1430H41AA GPH1436H41AA GPH1442H41AA GPH1448H41AA GPH1460H41AA
REPAIR PARTS GPH14 H-SERIES R-0A Package Heat Pumps GPH1424HAA GPH1430HAA GPH1436HAA GPH1442HAA GPH1448HAA GPH1460HAA This manual is to be used by qualified technicians only. 2009 Goodman Manufacturing
More informationFFHT1831QE2 FFHT1831QM2 FFHT1831QP2 FFHT1831QQ2 FFHT1831QS2
Product No. E2 M2 P2 Q2 S2 Series R134a R134a R134a R134a R134a Color black silver mist white bisque stainless Volts 115V 115V 115V 115V 115V Wiring Diagram A01475501 A01475501 A01475501 A01475501 A01475501
More informationMcQuay Climate Control. Water Source Heat Pump Horizontal. CC, CG, CW Vintage C, D. Last Manufactured: 1984
Replacement Parts List No. 055204000 Revision C 01/2017 McQuay Climate Control Water Source Heat Pump Horizontal CC, CG, CW 260-330 Vintage C, D Last Manufactured: 1984 To find your Daikin Applied parts
More informationREPAIR PARTS. GPC13 "M" Series 3-5 Ton Package Coolers
REPAIR PARTS GPC13 "M" Series 3-5 Ton Package Coolers GPC1336MAA GPC1336MBA GPC1336MCA GPC1336M43AA GPC1348MAA GPC1348MBA GPC1348MCA GPC1348M43AA GPC1348M43BA GPC1360MAA GPC1360MBA GPC1360MCA GPC1360M43AA
More informationSeries 3000 and XE-Series Engineering Data
Series 3000 and XE-Series Engineering Data A C A U S T R A L I A Series 3000 and XE-Series Engineering Data The NEW era of Series 3000 and XE-Series Cooling Towers continue to exceed the industry standard
More informationIndustrial Air Diffuser Type DLD for Heating and Cooling
LTG Incorporated Industrial Air Diffuser Type DLD for Heating and Cooling LTG Incorporated Corporate Drive, Suite E Spartanburg, SC 20 PO Box 288, Spartanburg, SC 20 USA Tel: 8--0 Fax: 8-- e-mail: info@ltg-inc.net
More informationParts Manual R410A Models
Parts Manual R410A Models PTAC - PD Series (Electronic Controls) Packaged Terminal Air Conditioners Packaged Terminal Heat Pumps PTAC PARTS E (1-2010) Table of Contents Unit Identification... 2 PTAC System
More information440V 500V V / / /2 12.
-26 Manual Motor Protectors March 0 B-Frame D-Frame Table -6. XTPR Rotary Manual Motor Protectors with Screw Terminals Global Ratings and North American Ratings Type and Type 2 Coordination Motor Protective
More informationSubmittals. Advanced Series 1U09ES2VHA / AW09ES2VH* 1U12ES2VHA / AW12ES2VH* 1U18ES2VHA / AW18ES2VH* 1U24ES2VHA / AW24ES2VH* Rev.
Submittals Advanced Series 1U09ES2VHA / AW09ES2VH* 1U12ES2VHA / AW12ES2VH* 1U18ES2VHA / AW18ES2VH* 1U24ES2VHA / AW24ES2VH* C US Intertek For more information visit us: www.haierductless.com www.haierductlesshelp.com
More informationSUBMITTAL DATA: MXZ-3C30NA MULTI-INDOOR INVERTER HEAT-PUMP SYSTEM
Job Name: System Reference: SUBMITTAL DATA: MXZ-3C30NA MULTI-INDOOR INVERTER HEAT-PUMP SYSTEM M-SERIES Date: GENERAL FEATURES Quiet Operation Optional base pan heater to prevent ice in drain pan Limited
More informationwww. ElectricalPartManuals. com Flexitest Switch Assemblies Type FT-19R and FT-19RX INTL APPLICATION
Effective: January 2004 Supersedes, dated June 1998 APPLICATION QUALITY FEATURES Descriptive Bulletin 41-078INTL Flexitest Switch Assemblies Type The type FT-19R (standard length) and FT-19RX (extended
More informationWorth noting. Introduction. Key figures. lindab architect. Picture 1. Architect Circum, Luna and Prisma.
Contact, Overview, Index Guideline heating and cooling Plexus Professor / Professor Plus Premum / Premax / Solus Architect Polaris I & S Plafond Podium Celo Cabinett Capella Carat Fasadium Atrium / Loggia
More informationSUBMITTAL DATA: MXZ-5C42NA MULTI-INDOOR INVERTER HEAT PUMP SYSTEM
Job Name: System Reference: SUBMITTAL DATA: MXZ-5C42NA MULTI-INDOOR INVERTER HEAT PUMP SYSTEM M-SERIES Date: GENERAL FEATURES Quiet Operation Optional base pan heater to prevent ice in drain pan Limited
More informationEXPLODED DIAGRAM - PARTS VIEW
Power Supply Sales Model: KSIL018-H216-I 208-230V~ / 1ph / 60Hz EXPLODED DIAGRAM - PARTS VIEW This information is to be used by qualify AC technicians only KSIL1816- Drawing No. D2IL16181301 Above information
More informationUL 1077 DIN Rail Supplementary Protectors
UL 0 DIN Rail Supplementary Protectors Product Overview UL 0 DIN Rail Supplementary Protectors PRODUCT OVERVIEW Product Overview Standard Features WMZS breaker terminals provide finger and back-of-hand
More informationTeSys enclosed starters 2
Characteristics, references TeSys enclosed starters D..L. starters for motor control 0. to. kw with -phase thermal overload relay with protected phases Characteristics () Conforming to standards IEC 0--,
More informationnufacturing Company, L.P San Felipe, Suite
REPAIR PARTS (2,3,4) Multi Zone Heat Pump Outdoor Unit 2MXS18GVJUAA 3MXS24JVJUAA 4MXS32GVJUAA nufacturing Company, L.P. 5151 San Felipe, Suite 500 www.amana-hac.com www.amana-hac.com This manual is to
More informationMethod of Measuring Machinery Sound Within an Equipment Space
ANSI/AHRI Standard 575 (Formerly ARI Standard 575) 2008 Standard for Method of Measuring Machinery Sound Within an Equipment Space Price $15.00 (M) $30.00 (NM) Printed in U.S.A. 8Copyright 1994, by Air-Conditioning
More information08/072 PKZ2 Motor-Protective Circuit-Breakers Tripping Characteristics
0/07 PKZ Tripping Characteristics Moeller HPL0-00/00 S-PKZ high-capacity contact module, SEA-PKZ contact module Normal switching duty AC-/00V kw A Rated output of three-phase motors 0...0 Hz. 7..... 0.7
More informationREPAIR PARTS. GPH13 "H" Model Package Heat Pumps GPH1324H41AB GPH1330H41AB GPH1336H41AB GPH1342H41AB GPH1348H41BB GPH1360H41BB
REPAIR PARTS GPH13 "H" Model Package Heat Pumps GPH1324H41AB GPH1330H41AB GPH1336H41AB GPH1342H41AB GPH1348H41BB GPH1360H41BB This manual is to be used by qualified technicians only. 2010 Goodman Manufacturing
More information6.0 EC-SERIES CUBERS EC200-EC300-EC400-EC500-EC606 AIR, WATER AND REMOTE
6.0 EC-SERIES CUBERS EC200-EC300-EC400-EC500-EC606 AIR, WATER AND REMOTE Item EC EC EC EC EC EC Code Part Description Part Number GRP 200 300 400 406 500 606 AIR COOLED 5 Air Condenser 9141048-01 AC X
More informationInstallation and Operation Manual. AllSync Plus Wired Clocks
and Operation Manual AllSync Plus Wired Clocks Part # H004881 Rev. 4 September 2018 Safety Precautions AllSync Plus Clock & Operation Manual Troubleshooting General Operation Introduction Safety Precautions
More informationHVAC Electrical Wiring Diagrams / Ohm s Law / Sequence of Operation RV
PLEASE DO NOT BOOKMARK ANY ANYTIMECE WEBPAGES! Our system will remember the last page you viewed when logging out and back in but please DO NOT exit out when taking a test. Your place will NOT be saved.
More informationREPAIR PARTS. GPH13 "M" Series Horizontal Package Heat Pumps GPH1324M41AA GPH1330M41AA GPH1336M41AA GPH1342M41AA GPH1348M41AA GPH1360M41AA
REPAIR PARTS GPH13 "M" Series Horizontal Package Heat Pumps GPH1324MAA GPH1330MAA GPH1336MAA GPH1342MAA GPH1348MAA GPH1360MAA This manual is to be used by qualified technicians only. 2009 Goodman Manufacturing
More informationALUMINIUM CENTRIFUGAL FANS. 4 x M6 x 16
DESCRIPTION Dutair BCT-series aluminium centrifugal fans with open die-cast aluminium impellers and forward curved blades are suitable for material transport and high pressure applications. The asynchronous
More informationALUMINIUM CENTRIFUGAL FANS M20 4 x M5 x 10 INLET. 4 x M5 x 12
BCT61 DESCRIPTION Dutair BCT-series aluminium centrifugal fans with open die-cast aluminium impellers and forward curved blades are suitable for material transport and high pressure applications. The asynchronous
More informationXHDU Cassette type fan-coils for double/four pipe connections 1,98-14 kw HYDRONIC TERMINALS
HYDRONIC TERMINALS XHDU 402 1203 Versions XHDU 2T XHDU-R 2T XHDU 4T XHDE 2T Single coil for double pipe connections Single coil for double pipe connections with heater Double coil for four pipe connections
More informationDBS315 1-phase SIDE CHANNEL BLOWERS
DBS15/ 1-phase DESCRIPTION Dutair blowers for pressure and vacuum are compact machines consisting of an electric motor with a built-on pump housing. The rotational speed of the impeller creates a high
More informationAC axial compact fan
ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-767 Mulfingen Phone +9 798 8-0 Fax +9 798 8-0 info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen Amtsgericht (court of registration)
More informationWISE Damper. Active damper for Swegon s WISE System for demand-controlled ventilation QUICK FACTS
Active damper for Swegon s WISE System for demand-controlled ventilation QUICK FACTS Variable or constant flow regulation or constant pressure regulation Wireless communication via radio Integrated sensor
More informationSemiconductor (AC) fuses
gr 690 VAC sizes 000 to (full range) Ferraz Shawmut PROTISTOR NH grb 690 VAC fuselinks provide maximum flexibility in equipment design and ultimate protection for today s power conversion equipment. This
More informationCONFIGURABLE CROSS-FLOW HEAT RECOVERY UNITS CADB/T-N Series
FILTERS F7 Compact heat recovery unit with cross-flow heat exchanger in 9 sizes from 500 m 3 /h to 8.350 m 3 /h. The casing is made from aluminium profile frame with double skinned 25 mm steel panels with
More informationBNA Series. PLENUM FAN with Backward Wheels
BNA Series PLENUM FAN with Backward Wheels BNA Series BNA Series Plenum Fans Backward wheels Kruger Plenum Fans are designed for air handling applications where the fan operates unhoused within a plenum.
More informationClausing Industrial, Inc. Variable Speed 20" Single and Multi-spindle, Belt Drive Industrial Drill Presses
www.clausing-industrial.com Variable Speed 20" Single and Multi-spindle, Belt Drive Industrial Drill Presses Clausing Industrial, Inc. Two Speed Variable Speeds 150-2000rpm Variable Speeds 200-1300rpm
More informationVariable swirl diffusers
Swirl diffusers, Variable swirl diffuser OD- Application Diffuser is designed for air conditioning of rooms with floor to ceiling highs of to 0 m and high induction requirements. It is suitable for large
More informationCommercial Generator Parts Catalog. PROTEC Series
Commercial Generator Parts Catalog PROTEC Series YD ÁÁ ÁÁ To avoid errors or delay in filling your parts order, always give the MODEL, SPEC NO. and SERIAL NO. from the Onan nameplate. For handy reference,
More information6 INCH W X 5-3/4 INCH D X 8-3/8 INCH H
0 South Street -, TX Nacogdoches Phone: -- Fax: -0- S0N0AN.KVA PH 0/V /V Buck Boost Transformer Eaton Corp Catalog Number S0N0AN Manufacturer Eaton Corp Description Buck Boost Transformer, Power Rating
More informationSound Rating of Ducted Air Moving and Conditioning Equipment
AHRI Standard 260 (I-P) 2017 Standard for Sound Rating of Ducted Air Moving and Conditioning Equipment IMPORTANT SAFETY DISCLAIMER AHRI does not set safety standards and does not certify or guarantee the
More informationSolenoid valves Type EVUL
Data sheet Solenoid valves EVUL EVUL solenoid valves are designed to fit into compact refrigeration systems. Available in servo operated versions they can be applied in liquid, suction, and hot gas lines.
More informationREPAIR PARTS. A/GPG13 Package Gas Units
REPAIR PARTS A/GPG13 Package Gas Units APG1324045MBA APG1324070MBA APG1330045MBA APG1330070MBA APG1336045MBA APG1336070MBA APG1336090MBA APG1342070MBA APG1342090MBA APG1348070MBA APG1348090MBA APG13485MBA
More informationThermal-Magnetic Circuit Breaker 2210-S2..
Thermal-Magnetic Circuit Breaker -S.. Description One, two and three pole thermal-magnetic circuit breakers with trip-free mechanism and toggle actuation (S-type TM CBE to EN 60934/IEC 934). Designed for
More informationREPAIR PARTS. GMS95 Single Stage Upflow Furnace GMS950453BXAB GMS950703BXAB GMS950704CXAB GMS950904CXAB GMS951155DXAB.
REPAIR PARTS GMS95 Single Stage Upflow Furnace GMS950453BXAB GMS950703BXAB GMS950704CXAB GMS950904CXAB GMS55DXAB Made in the USA by: Goodman Manufacturing Company, L.P. 2550 North Loop West, Suite 400
More informationPATENT PENDING. Easy Gripper product range. #94060 Easy Gripper #94095 Easy Gripper Compact Accessories. Improve SAFETY and efficiency
PATENT PENDING By Easy Gripper product range #94060 Easy Gripper #94095 Easy Gripper Compact Accessories Improve SAFETY and efficiency STANDARD OPTIONAL Your Easy Gripper Contact us to find out which Easy
More informationREPAIR PARTS. GPC15 Horizontal Package Cooling Units
REPAIR PARTS GPC15 Horizontal Package Cooling Units GPC1524H41AA GPC1524H41AB GPC1530H41AA GPC1530H41AB GPC1536H41AA GPC1536H41AB GPC1542H41AA GPC1542H41AB GPC1548H41AA GPC1548H41AB GPC1560H41AA GPC1560H41AB
More informationREPAIR PARTS. GPH16 Horizontal Package Heat Pumps. This manual is to be used by qualified technicians only.
REPAIR PARTS GPH16 Horizontal Package Heat Pumps GPH1624H41AA GPH1630H41AA GPH1636H41AA GPH1642H41AA GPH1648H41AA nufacturing Company, L.P. 5151 San Felipe, Suite 500 www.amana-hac.com www.amana-hac.com
More informationnufacturing Company, L.P San Felipe, Suite
Mini-Split Heat Pump Outdoor Unit RXS09LVJU RXS12LVJU RXS15LVJU RXS18LVJU RXS24LVJU REPAIR PARTS nufacturing Company, L.P. 5151 San Felipe, Suite 500 www.amana-hac.com www.amana-hac.com This manual is
More informationOverload Relays. SIRIUS 3RU1 Thermal Overload Relays. 3RU11 for standard applications. 5/46 Siemens LV 1 AO 2011
SIRIUS 3RU1 Thermal Overview 1 2 7 3 4 6 "Increased safety" type of EEx e according to ATEX directive 94/9/EC The 3RU11 thermal overload relays are suitable for the overload of explosion-proof motors with
More informationH i g h A m p e r a g e 2 5 t o A M P. T y p e I & I I I V e h i c l e P r o t e c t i o n. I P 6 7 W a t e r p r o o f
H i g h A m p e r a g e 2 5 t o 3 0 0 A M P T y p e I & I I I V e h i c l e P r o t e c t i o n I P 6 7 W a t e r p r o o f I g n i t i o n - P r o t e c t e d S A E & A B Y C C o m p l i a n t L E D T
More informationBlocks and Holders POWR-BLOKS. Connectors. Ampere Ratings. Ordering Information. Applications. Specifications. Distribution/Splicer Blocks and Covers
Connectors Box lug connectors are designed for use with a single, solid or class B or C stranded conductor. Use of more than one conductor per connector opening or use of extra-flexible, fine stranded
More informationPFI Closed circuit cooling towers
PFI Closed circuit cooling towers Key benefits Lowest energy consumption and total cost of ownership Year round reliable operation Ideal replacement unit with certified thermal performance PFI characteristics
More informationRemote Display Unit. Installers Handbook Copyright 2001 AirSense Technology Ltd. LM Remote Display Unit Installers Handbook Issue 1.
Remote Display Unit Installers Handbook Copyright 2001 AirSense Technology Ltd AirSense, ClassiFire, FastLearn PipeCAD, SenseNET, Stratos-HSSD and Stratos-Quadra are trademarks. HSSD is a Registered Trademark.
More informationSpecifications. Voltage Ratings: Interrupting Rating: Applications. Inverters Re-combiner boxes. LFJ 1000VDC Solar Series
0 VDC 125-4A Specifications Description The SPFJ series is the smallest 0VDC 125-4A photovoltaic fuse available in the market. The SPFJ series is manufactured in Class J case sizes that allows for both
More informationISEmax CAM40/CAS40. Technical Information
Technical Information Online measurement of nutrient parameters Ion-selective electrode system for the continuous measurement of ammonium and nitrate Application The ion-selective electrode system works
More informationISOCON-6. 24V AC or DC POWERED ISOLATING SIGNAL CONVERTER
ISOCON-6 24V AC or DC POWERED ISOLATING SIGNAL CONVERTER Whilst every effort has been taken to ensure the accuracy of this document, we accept no responsibility for damage, injury, loss or expense resulting
More informationThermal-Magnetic Circuit Breaker 2210-S2..
Thermal-Magnetic Circuit Breaker -S.. Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 60934/IEC 934). Designed for
More informationTangential Fans Series TW Impeller diameter 150 mm and 200 mm
Tangential Fans Series TW Impeller diameter mm and 0 mm 105 Corporate Drive, Suite E Spartanburg, SC 293 PO Box 2889, Spartanburg, SC 294 USA Tel: 864-599-63 Fax: 864-599-6344 e-mail: info@ltg-inc.net
More informationREPAIR PARTS. GPH14 H-Series Package Heat Pumps. This manual is to be used by qualified technicians only. This manual replaces RP-631C.
REPAIR PARTS GPH14 H-Series Package Heat Pumps GPH1424H41AB GPH1424H41AC GPH1424H41BA GPH1424H41CA GPH1424H41DA GPH1430H41AB GPH1430H41AC GPH1430H41BA GPH1430H41CA GPH1436H41AB GPH1436H41AC GPH1436H41BA
More information473 Dew Point Hygrometer
High Performance Chilled Mirror Hygrometer With Cable Mounted Measuring Heads Highly precise chilled mirror dew point technology Cable mounted dew point and temperature measurement Aspirated and direct
More informationALC. ALBATROSS Supply air terminal for large airflows
ALBATROSS Supply air terminal for large airflows Quick facts Large airflows Suitable for cooling or heating Manual or motorised adjustment Pressure drop independent of selected spread pattern Can be used
More informationALUMINIUM CENTRIFUGAL FANS. 4 x M6 x OUTLET x M6 x 20
DESCRIPTION Dutair LK-series industrial ventilators consist of a robust body made from die-cast aluminium alloy. Impellers are made of extruded aluminium. The asynchronous electric motors are maintenance
More informationALUMINIUM CENTRIFUGAL FANS x M6 x x M6 x 16
LK4 DESCRIPTION Dutair LK-series industrial ventilators consist of a robust body made from die-cast aluminium alloy. Impellers are made of extruded aluminium. The asynchronous electric motors are maintenance
More information