1 DESCRIPTION Dutair LK-series industrial ventilators consist of a robust body made from die-cast aluminium alloy. Impellers are made of extruded aluminium. The asynchronous electric motors are maintenance free and provided with long life ball bearings. All models have fully enclosed IP motors with a lip seal fitted to the drive shaft. The maximum ambient operating temperature is ºC and the maximum temperature of the gases to be handled is 8ºC. FEATURES all Dutair ventilators can be mounted in any position desired with the exception of the inlet pointing upwards the outlet can be rotated in eight positions high capacity for narrow ducting LK-series provide pressures of up to. kpa suction as well as pressure operation low vibration levels maintenance free many different applications BENEFITS very low noise levels at high performances accurate performance curves in a frequency range of to 8 Hz make Dutair fans suitable for applications with a wide operating area both suction and pressure performance curves for operation in Nm³/h detailed sound level data for acoustic purposes a variety of modifications are possible for non-standard applications n see notes on page GENERAL TECHNICAL DATA Hz Hz Power kw Voltage Δ / Y V /9 Current Δ / Y A.7/7.9 Revolutions /min 9 /79.7/7.9 8 Protection class IP IP Efficiency class IE IE Efficiency % 9. Power factor % 88. Sound pressure db(a) 78. Weight kg DIMENSIONS all dimensions in mm, tolerance +/- mm 7 x M x x M INLET B x OUTLET 7 8 x M x 8 CAD models available in STEP format in case of discrepancy between dimensional drawing and CAD model, dimensions in dimensional drawing take precedence Modifications reserved

2 PERFORMANCE Total pressure difference between inlet and outlet p t against airflow Q at an ambient condition of mbar and C. All duty points on thermal equilibrium 7. Flow is rated in Nm /h defined as air, mbar and C. Tolerance +/- %. See notes on page PRESSURE max 8 Hz V 8 7 Hz V 8 Hz V 8 Hz V Hz V Hz V Hz V Δp t [Pa] POWER Motor power P delivered at i m p e l l e r s h a f t. A m b i e n t condition of mbar and C. All duty points on t h e r m a l e q u i l i b r i u m 7. Tolerance +/- %. Accurate data on current consumption for specific duty points available on request PRESSURE P [kw] Modifications reserved

3 PERFORMANCE Total pressure difference between inlet and outlet p t against airflow Q at an ambient condition of mbar and C. All duty points on thermal equilibrium 7. Flow is rated in Nm /h defined as air, mbar and C. Tolerance +/- %. See notes on page VACUUM max 8 Hz V 8 7 Hz V 8 Hz V 8 Hz V Hz V Hz V Hz V Δp t [Pa] POWER Motor power P delivered at i m p e l l e r s h a f t. A m b i e n t condition of mbar and C. All duty points on t h e r m a l e q u i l i b r i u m 7. Tolerance +/- %. Accurate data on current consumption for specific duty points available on request VACUUM P [kw] Modifications reserved

4 SOUND LEVEL PRESSURE Hz 8 Nm /h. db(a) K K K 8K Hz Nm /h. db(a) K K K 8K Hz Nm /h 7. db(a) K K K 8K Hz 7 Nm /h 78. db(a) K K K 8K Hz Nm /h 8. db(a) K K K 8K 7 Hz Nm /h 87. db(a) K K K 8K 8 Hz Nm /h 9. db(a) K K K 8K SOUND LEVEL VACUUM Hz 8 Nm /h.9 db(a) K K K 8K Hz Nm /h. db(a) K K K 8K Hz Nm /h 7. db(a) K K K 8K Hz 7 Nm /h 78. db(a) K K K 8K Hz Nm /h 8. db(a) K K K 8K 7 Hz Nm /h 87. db(a) K K K 8K 8 Hz Nm /h 9. db(a) K K K 8K Modifications reserved

5 ORDERING INFORMATION LK 8 RD 7 U ss HT RS IP Q C... PTC Optional -piece PTC thermistors fitted in series in each motor phase Optional painting, standard RAL7 e.g. C7: RAL7 Optional Q: anti condensation heating V Optional motor protection: IP / IP, for IP specific mounting position Optional bearing material RS: Improved resistance against moisture Optional bearing lubrication HT: high temp. / LT: low temp. Optional bearing material ss: stainless steel Optional special motor voltage e.g. U-: V at Hz version Pumphouse orientation angle RD: Clockwise rotation sense Model size Model centrifugal fan : single phase / : three phase RD RD RD9 RD RD8 RD RD7 RD COMMENTS WARNING: Comparing performance data can be misleading. Dutair specifications are based on a thermal equilibrium 7 for all duty points along the characteristics curves in this document. Many commercial based flow characteristics curves defined as m³/h air at C, mbar(a) and +/- % tolerance but can be up to % higher than accurate characteristics curves defined as Nm³/h air at C, mbar(a), thermal equilibrium 7 duty points and +/- % tolerance as specified in this Dutair document. The performance measurements are executed with instruments calibrated by DNV KEMA and are traceable to primary and/or internationally accepted measurement standards. Maximum shaft power allowed at continuous operation. Rated output electric motor in accordance with NEN-EN-IEC -. Rated voltage for three phase triangle and star connection. Allowed supply voltage tolerance %. Consult your Dutair dealer for different supply voltages. Protection class in accordance with NEN-EN-IEC -. Efficiency classification in accordance with NEN-EN-IEC -. Efficiency rated at % motor load. Free field equivalent continuous sound pressure level A-weighted L eq[db(a)]. Unless specified L eq[db(a)] rated at % of maximum flow at Hz. Tolerance +/- db(a). Conditions as note. 7 Thermal equilibrium is the state reached when the temperature rises of several parts of the machine as well as the temperature rise between in- and outlet do not vary by more than a gradient of C per hour. 8 Operation at V within range of to 8 Hz: % of rated current at Hz is allowed for Hz power rating. 9 Free field class octave band measurements in accordance with IEC unweighted L p[db(z)]. Tolerance +/- db(z). Conditions as note. Measurements at m distance with in- and outlet duct connected to the fan on a reflective surface. Class sound level meter Delta Ohm HDUC/A according to IEC 7-. Acoustic calibration prior to measurements with class calibrator HDACC according to IEC 9. Standard ambient temperature range C. Modifications reserved

ALUMINIUM CENTRIFUGAL FANS x M6 x x M6 x 16

ALUMINIUM CENTRIFUGAL FANS x M6 x x M6 x 16 LK4 DESCRIPTION Dutair LK-series industrial ventilators consist of a robust body made from die-cast aluminium alloy. Impellers are made of extruded aluminium. The asynchronous electric motors are maintenance

More information

ALUMINIUM CENTRIFUGAL FANS. 4 x M6 x 16

ALUMINIUM CENTRIFUGAL FANS. 4 x M6 x 16 DESCRIPTION Dutair BCT-series aluminium centrifugal fans with open die-cast aluminium impellers and forward curved blades are suitable for material transport and high pressure applications. The asynchronous

More information

ALUMINIUM CENTRIFUGAL FANS M20 4 x M5 x 10 INLET. 4 x M5 x 12

ALUMINIUM CENTRIFUGAL FANS M20 4 x M5 x 10 INLET. 4 x M5 x 12 BCT61 DESCRIPTION Dutair BCT-series aluminium centrifugal fans with open die-cast aluminium impellers and forward curved blades are suitable for material transport and high pressure applications. The asynchronous

More information

DBS315 1-phase SIDE CHANNEL BLOWERS

DBS315 1-phase SIDE CHANNEL BLOWERS DBS15/ 1-phase DESCRIPTION Dutair blowers for pressure and vacuum are compact machines consisting of an electric motor with a built-on pump housing. The rotational speed of the impeller creates a high

More information

AC axial fan. Limited partnership Headquarters Mulfingen Amtsgericht (court of registration) Stuttgart HRA

AC axial fan. Limited partnership Headquarters Mulfingen Amtsgericht (court of registration) Stuttgart HRA ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-767 Mulfingen Phone +9 798 8- Fax +9 798 8- info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen Amtsgericht (court of registration)

More information

AC axial fan. Limited partnership Headquarters Mulfingen Amtsgericht (court of registration) Stuttgart HRA

AC axial fan. Limited partnership Headquarters Mulfingen Amtsgericht (court of registration) Stuttgart HRA ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-767 Mulfingen Phone +9 798 8-0 Fax +9 798 8-0 info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen Amtsgericht (court of registration)

More information

Mechanical flow-rate controllers

Mechanical flow-rate controllers L D L D L D Mechanical flow-rate controller MRP-1 (Circular) Description With the circular air flow controllers with automated action, the air flow rate is controlled via an asymmetrical control flap pivoting

More information

ELMO-G Vacuum Pumps/Compressors, Range 2BH1, Three-Phase 50 Hz

ELMO-G Vacuum Pumps/Compressors, Range 2BH1, Three-Phase 50 Hz ELMO- Vacuum Pumps/Compressors, Range 2BH1, Three-Phase 50 Hz Selection diagram vacuum operation Selection diagram compressor operation The performance curves are valid for pumping air at 15 C at the inlet

More information

Tangential Fans Series TW Impeller diameter 150 mm and 200 mm

Tangential Fans Series TW Impeller diameter 150 mm and 200 mm Tangential Fans Series TW Impeller diameter mm and 0 mm 105 Corporate Drive, Suite E Spartanburg, SC 293 PO Box 2889, Spartanburg, SC 294 USA Tel: 864-599-63 Fax: 864-599-6344 e-mail: info@ltg-inc.net

More information

AC axial compact fan

AC axial compact fan ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-767 Mulfingen Phone +9 798 8- Fax +9 798 8- info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen County court Stuttgart HRA 59

More information

BNA Series. PLENUM FAN with Backward Wheels

BNA Series. PLENUM FAN with Backward Wheels BNA Series PLENUM FAN with Backward Wheels BNA Series BNA Series Plenum Fans Backward wheels Kruger Plenum Fans are designed for air handling applications where the fan operates unhoused within a plenum.

More information

Single Phase Motors Technical Datasheets

Single Phase Motors Technical Datasheets Single Phase Motors Technical Datasheets EN A dynamic, strong and ambitious Group: Orange1 Holding is an international renown Group, one of the most important European manufacturers of single-phase and

More information

CNA-CNB. Centrifugal fans

CNA-CNB. Centrifugal fans NA-NB entrifugal fans Product facts Product Single-inlet low-pressure fans with backward-curved blades. Use In industrial ventilation systems for uncontaminated, non-corrosive air, max. 70 º, where a low

More information

AC axial compact fan

AC axial compact fan ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-767 Mulfingen Phone +9 798 8-0 Fax +9 798 8-0 info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen Amtsgericht (court of registration)

More information

AC axial compact fan

AC axial compact fan ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-767 Mulfingen Phone +9 798 8-0 Fax +9 798 8-0 info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen Amtsgericht (court of registration)

More information

Contents. Identification LHC. Horizontal split case pumps. Type key. Identification Type key

Contents. Identification LHC. Horizontal split case pumps. Type key. Identification Type key Contents dentification Type key Product data ntroduction Applications Features and benefits Performance range pole pole pole Construction Sectional drawing Construction features Test pressure Operating

More information

AC axial compact fan

AC axial compact fan ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-7467 Mulfingen Phone +49 798 8-0 Fax +49 798 8-0 info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen County court Stuttgart HRA

More information

variable flow dampers

variable flow dampers Constant-/ DAU, DAEU, DAVU Summary DAU - manual single flow unit DAEU - motorized twin flow unit DAVU - motorized variable flow unit Diameters Ø 0 Flow range 0 l/s ( m³/h) Pressure range Pa (over the unit)

More information

VK2 volume flow controller Overview

VK2 volume flow controller Overview New option with sound attenuator Maintenance-free VK2 volume flow controller that operates without an auxiliary power supply, for ventilation and air conditioning systems. Adjustable on site. Outstanding

More information

THE ENERGY 68,SAVING TDVI. exible Combine Modular 24, 26, 28, 30, 32, 34, 36, 38, 40, 42, 44 HP 60, 62, 64, 66 HP

THE ENERGY 68,SAVING TDVI. exible Combine Modular 24, 26, 28, 30, 32, 34, 36, 38, 40, 42, 44 HP 60, 62, 64, 66 HP I N V E RT E R ion Range exible Combine Modular TDV I TDV I TDV I INVERTER INVERTER INVERTER 14, 16, 18, 20, 22 HP TDV I 24, 26, 28, 30, 32, 34, 36, 38, 40, 42, 44 HP INVERTER INVERTER INVERTER TDV I INVERTER

More information

Calio-Therm NC Type Series Booklet

Calio-Therm NC Type Series Booklet High-efficiency Drinking Water Pump Type Series Booklet Legal information/copyright Type Series Booklet All rights reserved. The contents provided herein must neither be distributed, copied, reproduced,

More information

G_Series. Gas Ring Blowers US Edition

G_Series. Gas Ring Blowers US Edition _Series as Ring Blowers US Edition History In May 2002 the Nash Engineering Company, USA, and elmo vacuum technology mbh, ermany, formerly a Siemens subsidiary, merged to create a global leader in vacuum

More information

CMA - B - C - D - CMR

CMA - B - C - D - CMR Cast iron self-priming electric pumps. APPLICATIONS Pressure boosting domestic plants Small-scale irrigation Moving non-aggressive liquids for civil and industrial use Washing plants Washing vehicles CMA-B-C-D

More information

System Components. Electric Motors.

System Components. Electric Motors. System Components Electric Motors www.powerjacks.com Contents.1. Electric Motors.1.1. AC Motors.1.. AC Motor Performance 0 rpm ( pole).1.. AC Motor Performance 00 rpm ( pole).1.. AC Motors with Integral

More information

barmesapumps.com SELF-PRIMING CENTRIFUGAL TRASH PUMP SPECIFICATIONS Series: SH8-U Suction: 8" Discharge: 8" Spherical solids handling: 3"

barmesapumps.com SELF-PRIMING CENTRIFUGAL TRASH PUMP SPECIFICATIONS Series: SH8-U Suction: 8 Discharge: 8 Spherical solids handling: 3 SELF-PRIMING CENTRIFUGAL TRASH PUMP Series: SH-U Suction: " Discharge: " Spherical solids handling: 3" SIZE BEARING - PUMP END " x " NPT, lbs., female flange. Open single ball, radial load. LIQUID TEMPERATURE

More information

DS 300. Electronic Pressure Switch. with IO-Link interface. Stainless Steel Sensor. accuracy according to IEC 60770: 0.35 % FSO.

DS 300. Electronic Pressure Switch. with IO-Link interface. Stainless Steel Sensor. accuracy according to IEC 60770: 0.35 % FSO. DS 00 Electronic Pressure Switch with IO-Link interface Stainless Steel Sensor accuracy according to IEC 60770: 0.5 % FSO Nominal pressure from 0... 00 mbar up to 0... 600 bar Digital output signal IO-Link

More information

maintenance-free in continuous duty low-noise space-saving extremely tough Suction capacity in m 3 /h m 3 /h 2500 Suction capacity 30,000 10,000

maintenance-free in continuous duty low-noise space-saving extremely tough Suction capacity in m 3 /h m 3 /h 2500 Suction capacity 30,000 10,000 Suction capacity in m /h m /h 20 2000 1000 0 00 2 200 1 100 10 700 0 0 400 00 200 100 0 100 200 00 400 0 0 700 800 900 1000 1100 Suction pressure auge pressure mbar ELMO- vacuum pumps and compressors convey

More information

Air Cooler Industry AC-LN 1-7 / ACA-LN 2-7 / ACAF-LN 2-7

Air Cooler Industry AC-LN 1-7 / ACA-LN 2-7 / ACAF-LN 2-7 ir ooler Industry -LN -7 / -LN -7 / F-LN -7 Symbol General The -LN -7 air cooler series can be used in all areas where either oil or water-glycol is to be cooled with air. The coolers with an axial fan

More information

Samos SI E1/E2

Samos SI E1/E2 Samos SI E/E Samos SI E Description Busch Samos SI regenerative blowers are designed for either pressure or vacuum. They are available in single and two stage models so they can operate over a wide range

More information

ISO 5136 INTERNATIONAL STANDARD. Acoustics Determination of sound power radiated into a duct by fans and other air-moving devices In-duct method

ISO 5136 INTERNATIONAL STANDARD. Acoustics Determination of sound power radiated into a duct by fans and other air-moving devices In-duct method INTERNATIONAL STANDARD ISO 5136 Second edition 2003-04-01 Acoustics Determination of sound power radiated into a duct by fans and other air-moving devices In-duct method Acoustique Détermination de la

More information

K DOUBLE-IMPELLER DOUBLE-IMPELLER ELECTRIC PUMPS

K DOUBLE-IMPELLER DOUBLE-IMPELLER ELECTRIC PUMPS K DOUBLE-IMPELLER DOUBLE-IMPELLER ELECTRIC PUMPS ENERGY EFFICIENCY 7.5 TECHNICL DT Operating range: from,2 to 3 m 3 /h with head up to 97 metres. Pumped liquid: clean, free of solids and abrasives, non-viscous,

More information

EVOTRON WET ROTOR ELECTRONIC CIRCULATORS TECHNICAL DATA APPLICATIONS ADVANTAGES

EVOTRON WET ROTOR ELECTRONIC CIRCULATORS TECHNICAL DATA APPLICATIONS ADVANTAGES TECNICAL DATA EVOTRON Operating range: from, -, m3/h with head of up to metres. Pumped liquid temperature range: from - C to + C. Working pressure: bar ( kpa). Protection class: IP X. Insulation class:

More information

Multi-Speed Three-Phase Induction Motors

Multi-Speed Three-Phase Induction Motors Multi-Speed Three-Phase Induction Motors Including Motors for Fan Applications Product Catalogue Multi-Speed Three-Phase Induction Motors Certificates Cantoni Motor SA ISO 0 KEMA Since September 0, 999

More information

Turbine Meter TRZ 03 PRODUCT INFORMATION. Reliable Measurement of Gas

Turbine Meter TRZ 03 PRODUCT INFORMATION. Reliable Measurement of Gas Turbine Meter TRZ 0 PRODUCT INFORMATION Reliable Measurement of Gas TURBINE METER TRZ 0 Method of operation, Construction Method of operation The TRZ 0 turbine meter is a flow meter suitable for gas measurement

More information

MULTISTAGE CENTRIFUGAL PUMP TPH 2/4/8/12/25/50T. 50Hz. WALRUS PUMP ISO 9001 Certified

MULTISTAGE CENTRIFUGAL PUMP TPH 2/4/8/12/25/50T. 50Hz. WALRUS PUMP ISO 9001 Certified MULTISTAGE CENTRIFUGAL PUMP TPH /////T Hz WALRUS PUMP ISO Certified TPH Applications The WALRUS TPH Series is horizontal multistage centrifugal pump, suitable for clean water/liquid without abrasive matters.

More information

High-efficiency Circulator Pump. Rio-Eco N / Rio-Eco Z N. Type Series Booklet

High-efficiency Circulator Pump. Rio-Eco N / Rio-Eco Z N. Type Series Booklet High-efficiency Circulator Pump Rio-Eco N / Rio-Eco Z N Type Series Booklet Legal information/copyright Type Series Booklet Rio-Eco N / Rio-Eco Z N KSB Aktiengesellschaft All rights reserved. The contents

More information

PiB Series. PiB (Pump-in-a-Box) 4380 & 4392 Series

PiB Series. PiB (Pump-in-a-Box) 4380 & 4392 Series PiB Series PiB (Pump-in-a-Box) & 9 Series FILE NO: - DATE: July SUPERSEDES: - DATE: January 09 PiB Series Guaranteed In Stock At The Right Price! The PiB series builds on the high quality and unsurpassed

More information

Centrifugal Fans double inlet with direct drive backwardcurved true airfoil blades. Issue 1.4 September 2013

Centrifugal Fans double inlet with direct drive backwardcurved true airfoil blades. Issue 1.4 September 2013 Centrifugal Fans double inlet with direct drive backwardcurved true airfoil blades Issue 1.4 September 013 1 The overall picture will decide Complete systems by Nicotra ebhardt Depending on the model of

More information

FAN TERMINOLOGY. t = 1.2 kg/m 3 (Standard air density at 20 C and 1013mb. V = duct air velocity, m/s.

FAN TERMINOLOGY. t = 1.2 kg/m 3 (Standard air density at 20 C and 1013mb. V = duct air velocity, m/s. +7 (0)1 55 1077 +7 (0)1 55 797 FAN TERMINOLOGY These notes are designed to explain some of the terms that are used in describing the characteristics of fans and the relationship between the fan performance

More information

Air distribution systems. Adjustable radial outlet RA-V...

Air distribution systems. Adjustable radial outlet RA-V... Air distribution systems Adjustable radial outlet RA-V... DS E 0.2013 Construction design Preliminary remarks KRANTZ KOMPONENTEN has developed its wellknown, successful radial outlet into an adjustable

More information

Method of Measuring Machinery Sound Within an Equipment Space

Method of Measuring Machinery Sound Within an Equipment Space ANSI/AHRI Standard 575 (Formerly ARI Standard 575) 2008 Standard for Method of Measuring Machinery Sound Within an Equipment Space Price $15.00 (M) $30.00 (NM) Printed in U.S.A. 8Copyright 1994, by Air-Conditioning

More information

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm DMP P Industrial Pressure Transmitter Process Connections With Flush Welded Stainless Steel accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 % FSO Nominal pressure from 0... 00 mbar up

More information

E8EB-N0C2B E8EB-N0B2B

E8EB-N0C2B E8EB-N0B2B Slim Sensor CSM DS_E 1 Ideal for Workpiece Position and Original Checking The to 1 kpa model can be used for workpiece position checking. The to 1MPa model is ideal for original pressure checking. Degree

More information

Dimensions. Order code. Materials and finish. lindab ceiling diffusers

Dimensions. Order code. Materials and finish. lindab ceiling diffusers LKP Description LCP is a flush-mounted square diffuser with a circular unperforated face plate for installation in ceiling systems. LCP can be used for both supply and exhaust air. LCP is suitable for

More information

Digital AC Motors MHD

Digital AC Motors MHD Digital AC Motors MHD090 8-1 8 MHD090 8.1 Technical Data Description Symbol Unit MHD090B-035 Type of cooling Natural Natural Surface Liquid Motor overtemperature 60 K 100 K 60 K/100 K 60 K/100 K Electric

More information

WISE Damper. Active damper for Swegon s WISE System for demand-controlled ventilation QUICK FACTS

WISE Damper. Active damper for Swegon s WISE System for demand-controlled ventilation QUICK FACTS Active damper for Swegon s WISE System for demand-controlled ventilation QUICK FACTS Variable or constant flow regulation or constant pressure regulation Wireless communication via radio Integrated sensor

More information

I/IN (D) Kriva momenta i struje Torque and current curves Moment und Strom Kurven. - a / r

I/IN (D) Kriva momenta i struje Torque and current curves Moment und Strom Kurven. - a / r I/IN (D) 4.5 M/M N Kriva momenta i struje Torque and current curves Moment und Strom Kurven 1459-69V,D/4 5kW/ 5Hz - a / r I/I N 9. I/I N (D) 4. 8. 3.5 7. 3. 6. 2.5 5. 2. 4. M/M N (D) 1.5 3. I/I N (Y) 1.

More information

TOLERANCES AND UNCERTAINTIES IN PERFORMANCE DATA OF REFRIGERANT COMPRESSORS JANUARY 2017

TOLERANCES AND UNCERTAINTIES IN PERFORMANCE DATA OF REFRIGERANT COMPRESSORS JANUARY 2017 TOLERANCES AND UNCERTAINTIES IN PERFORMANCE DATA OF REFRIGERANT COMPRESSORS JANUARY 017 111 Wilson Blvd, Suite 500 Arlington, Virginia 01 USA +001 (703) 54-8800 Published by: TABLE OF CONTENTS SECTION

More information

143 EEX gerotor pump unit. For use in oil circulation systems in gas- and dust-ex-atmospheres

143 EEX gerotor pump unit. For use in oil circulation systems in gas- and dust-ex-atmospheres 1 EEX gerotor pump unit For use in oil circulation systems in gas- and dust-ex-atmospheres Gerotor pump series 1 EEX The 1 EEX product series has been specifically designed for centralized lubrication

More information

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm DMP Pi Precision Pressure Transmitter pressure ports and process connections with flush welded stainless steel diaphragm accuracy according to IEC 600: 0, % FSO Nominal pressure from 0... 00 mbar up to

More information

Solenoid valves Type EVUL

Solenoid valves Type EVUL Data sheet Solenoid valves EVUL EVUL solenoid valves are designed to fit into compact refrigeration systems. Available in servo operated versions they can be applied in liquid, suction, and hot gas lines.

More information

Swirl Diffusers Type DLA 7 and DLA 8

Swirl Diffusers Type DLA 7 and DLA 8 LTG Incorporated Swirl Diffusers Type DLA 7 and DLA 8 LTG Incorporated 1 Corporate Drive, Suite D Spartanburg, SC 93 PO Box 889, Spartanburg, SC 9 USA Tel: 86-599-63 Fax: 86-599-63 e-mail: info@ltg-inc.net

More information

Usage limitations and accuracies of platinum resistance thermometers (DIN EN 60751:2009) in industrial applications

Usage limitations and accuracies of platinum resistance thermometers (DIN EN 60751:2009) in industrial applications Technical information Usage limitations and accuracies of platinum resistance thermometers (DIN EN 60751:2009) in industrial applications WIKA data sheet IN 00.17 General information Temperature is a measurement

More information

High Voltage DC Y5U Disc Capacitor Range

High Voltage DC Y5U Disc Capacitor Range High Voltage DC Y5U Disc Capacitor Range T H E C E R A M I C E X P E R T S High Voltage DC Y5U Disc Capacitor Range The CeramTec Group is a world leader in the design and manufacture of complex electronic

More information

SINGLE IMPELLER CENTRIFUGAL ELECTRIC PUMPS in cast iron

SINGLE IMPELLER CENTRIFUGAL ELECTRIC PUMPS in cast iron Cast iron self-priming electric pumps. APPLICATIONS Pressure boosting domestic plants Small-scale irrigation Moving non-aggressive liquids for civil and industrial use Washing plants Washing vehicles CMA-B-C-D

More information

IM 1001 IM 3001 (1) IM 2001 (1) IM 3601 (1) IM 2101 (1) at 50/60 Hz (IM B3) (IM B5) (IM B35) (IM B14) (IM B34) Max. Max.

IM 1001 IM 3001 (1) IM 2001 (1) IM 3601 (1) IM 2101 (1) at 50/60 Hz (IM B3) (IM B5) (IM B35) (IM B14) (IM B34) Max. Max. 2016/09/05 version 230 V Δ / 380 V Υ / 400 V Υ / 415 V Υ 50 Hz - 460 V Υ 60 Hz L 0.75 4910125 10 4910126 4 4910127 1 4910129 1 4910130 1 LG 1.1 4910138 10 4910139 4 4910140 1 4910142 1 4910143 1 SL 1.5

More information

Supply air beam. Contact, Overview, Index. Guideline heating and cooling. Plexus. Professor / Professor Plus. Premum / Premax / Solus.

Supply air beam. Contact, Overview, Index. Guideline heating and cooling. Plexus. Professor / Professor Plus. Premum / Premax / Solus. Contact, Overview, Index Guideline heating and cooling Plexus Professor / Professor Plus Premum / Premax / Architect Polaris I & S Plafond Podium Celo Cabinett Capella Carat Fasadium Atrium / Loggia Regula

More information

TPH. 60Hz. Standard mode TPH 4T 2K. Code TPH 4T 2K S F A H

TPH. 60Hz. Standard mode TPH 4T 2K. Code TPH 4T 2K S F A H C US NSF/ANSI TPH Applications: The TPH Series are modernly designed with quiet and high efficient operation pumps, suitable for dependable water transfer, circulating or booster service. -Industrial circulation

More information

VRF Technical Data Book

VRF Technical Data Book VRF Technical Data Book DVM S for Euro_ET (R4A, Hz, HP) Model : Premium (Compact / Energy Efficiency) Type Standard Type History Version Modification Date Remark Ver. 1. Release DVM S (R4A, Hz, HP) for

More information

50 Hz n= 2900 rpm. Standardised EN 733 centrifugal pumps INSTALLATION AND USE. PERFORMANCE RANGE Flow rate up to 6000 l/min (360 m³/h) Head up to 98 m

50 Hz n= 2900 rpm. Standardised EN 733 centrifugal pumps INSTALLATION AND USE. PERFORMANCE RANGE Flow rate up to 6000 l/min (360 m³/h) Head up to 98 m F Standardised EN 733 centrifugal pumps Hz n= 9 rpm Clean water Industrial use PERFORMNCE RNGE Flow rate up to (3 ) Head up to 9 m PPLICTION LIMITS Manometric suction lift up to 7 m Liquid temperature

More information

CDD/CDR. Circular ceiling diffuser for supply air QUICK FACTS

CDD/CDR. Circular ceiling diffuser for supply air QUICK FACTS Circular ceiling diffuser for supply air QUICK FACTS Spread pattern can be shielded Used with commissioning box ALS Cleanable Adjustable slot Perforated diffuser face = CDD Non-perforated diffuser face

More information

TPH Series WALRUS PUMP. Multi-stage Centrifugal Pump. All specifications are subject to change without notice. 014

TPH Series WALRUS PUMP. Multi-stage Centrifugal Pump. All specifications are subject to change without notice. 014 T Series WLRUS PUMP ll specifications are subject to change without notice. Multistage entrifugal Pump T T pplications The WLRUS T Series is horizontal multistage centrifugal pump, suitable for clean water/liquid

More information

Contents. Performance Curves/Technical Data. General Data Performance Range Sectional Drawing TPH 2T TPH 4T TPH 8T TPH 12T TPH 25T TPH 50T

Contents. Performance Curves/Technical Data. General Data Performance Range Sectional Drawing TPH 2T TPH 4T TPH 8T TPH 12T TPH 25T TPH 50T Contents General Data Performance Range Sectional Drawing Performance Curves/Technical Data T T T T T 8T T T T T T T 7 9 T Series Multistage Centrifugal Pump Hz Power:.. kw Head: Up to 7M Flow: Up to L/min

More information

Single Phase Motors Technical Datasheets

Single Phase Motors Technical Datasheets Single Phase Motors Technical Datasheets EN A dynamic, strong and ambitious Group: Orange1 Holding is an international renown Group, one of the most important European manufacturers of single-phase and

More information

Plain diffuser. Dimensions

Plain diffuser. Dimensions Dimensions Ø U Ød B C Ø E Ø A Description is a circular diffuser with an unperforated adjustable face plate and can be used for both supply and extract air. The diffuser can be switched between horizontal

More information

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor DMP Industrial Pressure Transmitter for Low Pressure Stainless Steel Sensor accuracy according to IEC 60770: : 0.5 % FSO option: 0.5 / 0. % FSO Nominal pressure from 0... 00 mbar up to 0... 60 bar Output

More information

P U M P S. The quality standard for hydraulic efficiency and suction lift. PERIPHERAL PUMPS TEP/ TSP - SERIES 50Hz

P U M P S. The quality standard for hydraulic efficiency and suction lift. PERIPHERAL PUMPS TEP/ TSP - SERIES 50Hz P U M P S THE BENCHMARK FOR PERFORMANCE The quality standard for hydraulic efficiency and suction lift. PERIPHERAL PUMPS TEP/ TSP - SERIES 5Hz I N D E X TEP / TSP SERIES - PERIPHERAL PUMPS Page No. General

More information

Nozzles. About Lindab. Comfort and Design. Product overview / symbols. Theory. Ceiling diffusers. Ceiling diffusers - visible.

Nozzles. About Lindab. Comfort and Design. Product overview / symbols. Theory. Ceiling diffusers. Ceiling diffusers - visible. Nozzles About Lindab Comfort and Design Product overview / symbols Theory Ceiling diffusers Ceiling diffusers - visible Plenum boxes Wall diffusers Nozzles Ventiduct Grilles Displacement diffusers VAV

More information

Worth noting. Introduction. Key figures. lindab architect. Picture 1. Architect Circum, Luna and Prisma.

Worth noting. Introduction. Key figures. lindab architect. Picture 1. Architect Circum, Luna and Prisma. Contact, Overview, Index Guideline heating and cooling Plexus Professor / Professor Plus Premum / Premax / Solus Architect Polaris I & S Plafond Podium Celo Cabinett Capella Carat Fasadium Atrium / Loggia

More information

792A AC/DC Transfer Standard

792A AC/DC Transfer Standard 92A AC/DC Transfer Standard Technical Data Support for your most demanding ac measurement requirements ppm total uncertainty Traceable to national standards range: 2 mv to 00 V Frequency range: Hz to 1

More information

PELICAN Ceiling HF. Square extract air diffuser QUICK FACTS

PELICAN Ceiling HF. Square extract air diffuser QUICK FACTS Square extract air diffuser QUICK FACTS Perforated air diffuser front face Manages large extract airflows Flush design Designed for modular suspended ceilings Quick Access front face Can be combined with

More information

Dimensional drawing face mount flange radial. R = bending radius min. 40 mm. Dimensional drawing face mount flange axial

Dimensional drawing face mount flange radial. R = bending radius min. 40 mm. Dimensional drawing face mount flange axial Incremental Encoder DRS/DRS, face mount flange up to 8,2 Dimensional drawing face mount flange radial Incremental Encoder Connector or cable outlet Protection class up to IP s TTL and HTL Zero-Pulse-Teach

More information

CROSS FLOW COOLING TOWER

CROSS FLOW COOLING TOWER CROSS FLOW COOLING TOWER LUCKY GREEN THAI INDUSTRIES CO LTD Material Specification Model LGX 80 00 0 00 0 300 30 400 00 600 700 800 000 Motor Totally enclosed Totally enclosed fan cooled Driving System

More information

0T 0TS S T TS T TS T TS 0T T T T T T 6T T TS 6T 6TS T TS 6T 6TS 6T 6TS 6T 6TS Frame.. 6. 6 6... 6.... B 6 6... A..... 0..0... 6.... 6.....06 6.66.. 6.0.....6 0... C 6..0 6. 6....... E.. D....... F 6............

More information

6 INCH W X 5-3/4 INCH D X 8-3/8 INCH H

6 INCH W X 5-3/4 INCH D X 8-3/8 INCH H 0 South Street -, TX Nacogdoches Phone: -- Fax: -0- S0N0AN.KVA PH 0/V /V Buck Boost Transformer Eaton Corp Catalog Number S0N0AN Manufacturer Eaton Corp Description Buck Boost Transformer, Power Rating

More information

4.2. Ex-Ceiling light fittings AB 80 / AB 05 LED / AB 05 / AB 12 NAV 70. (Zone 1, 2, 21, 22)

4.2. Ex-Ceiling light fittings AB 80 / AB 05 LED / AB 05 / AB 12 NAV 70. (Zone 1, 2, 21, 22) .2 Ex-Ceiling light fittings AB 8 / AB 5 LED / AB 5 / AB 12 NAV 7 (Zone 1, 2, 21, 22) The wall and ceiling light fixtures for particularly difficult operating conditions The impact-resistant and flameproof

More information

DRS 61: Incremental encoders, number of lines and zero pulse width freely programmable DRS 60: Incremental Encoders with Zero-Pulse-Teach

DRS 61: Incremental encoders, number of lines and zero pulse width freely programmable DRS 60: Incremental Encoders with Zero-Pulse-Teach NEW DRS : Incremental encoders, number of lines and zero pulse width freely programmable DRS : s with Zero-Pulse-Teach Further highlights of this generation of encoders: Simple zero-pulse-teach by pressing

More information

VersaFlow Ultrasonic clamp-on Flowmeter Specifications

VersaFlow Ultrasonic clamp-on Flowmeter Specifications VersaFlow Ultrasonic clamp-on Flowmeter Specifications 34-VF-03-14 September 2009 Clamp-On Technology HONEYWELL S VersaFlow stands for continuity and long term reliability. Flow measurement can be done

More information

Grille. Min. - max. dimensions

Grille. Min. - max. dimensions Min. - max. dimensions H L 0 00 75 00 Standard grilles are available with mm pitch within the above min. and max. sizes. Customized sizes available on request. Description is an adjustable single or double

More information

EUROVENT 8/12 SOUND TEST METHOD FOR DUCTED FAN COIL UNITS. FCP 2008 testing procedures FCP acoustical test method pag. 1

EUROVENT 8/12 SOUND TEST METHOD FOR DUCTED FAN COIL UNITS. FCP 2008 testing procedures FCP acoustical test method pag. 1 EUROVENT 8/12 SOUND TEST METHOD FOR DUCTED FAN COIL UNITS FCP 2008 testing procedures FCP acoustical test method pag. 1 CONTENTS 1 - PURPOSE... 3 2 - NORMATIVE REFERENCES... 3 3 - DEFINITIONS... 3 3.1

More information

CapaciTorr HV Pumps. making innovation happen,together

CapaciTorr HV Pumps. making innovation happen,together CapaciTorr HV Pumps making innovation happen,together CapaciTorr HV HIGHLIGHTS General Features High pumping speed for all active gases High sorption capacity and increased lifetime Constant pumping speed

More information

GRUNDFOS DATA BOOKLET MAGNA, UPE. Series 2000 circulator pumps

GRUNDFOS DATA BOOKLET MAGNA, UPE. Series 2000 circulator pumps GRUNDFOS DATA BOOKLET Series circulator pumps Contents Product data MAGNA and UPE 3 Duty range 3 Characteristic features 3 Benefits 3 Applications 3 eating systems 3 Pumped liquids Type key 5 Performance

More information

NM, NMD 60 Hz NM, NMD. Close Coupled Centrifugal Pumps with threaded ports

NM, NMD 60 Hz NM, NMD. Close Coupled Centrifugal Pumps with threaded ports , D z Close Coupled Centrifugal ups Construction Close-coupled, centrifugal pups; electric otor with extended sha directly connected to the pup. : single-ipeller D: with two back-to-back ipellers (with

More information

Air distribution systems. Jet nozzle DW-N2... Swivel jet nozzle DW-V2... Twist nozzle DW-V2-...-DR

Air distribution systems. Jet nozzle DW-N2... Swivel jet nozzle DW-V2... Twist nozzle DW-V2-...-DR Air distribution systems Jet nozzle DW-N... Swivel jet nozzle DW-V... Twist nozzle DW-V-...-DR DS E 01. Jet nozzle and twist nozzle Preliminary remarks Jet nozzle DW N Swivel jet nozzle DW V Twist nozzle

More information

UNIT 4 FLYWHEEL 4.1 INTRODUCTION 4.2 DYNAMICALLY EQUIVALENT SYSTEM. Structure. Objectives. 4.1 Introduction

UNIT 4 FLYWHEEL 4.1 INTRODUCTION 4.2 DYNAMICALLY EQUIVALENT SYSTEM. Structure. Objectives. 4.1 Introduction UNIT 4 FLYWHEEL Structure 4.1 Introduction Objectives 4. Dynamically Equivalent System 4.3 Turning Moment Diagram 4.3.1 Turning Moment Diagram of a Single Cylinder 4-storke IC Engine 4.3. Turning Moment

More information

CapaciTorr HV 200 HIGHLIGHTS

CapaciTorr HV 200 HIGHLIGHTS CapaciTorr HV 200 General Features High pumping speed for all active gases High sorption capacity and increased lifetime Costant pumping speed in HV, UHV and XHV Reversible pumping of hydrogen and its

More information

CHAPTER 3 ENERGY EFFICIENT DESIGN OF INDUCTION MOTOR USNG GA

CHAPTER 3 ENERGY EFFICIENT DESIGN OF INDUCTION MOTOR USNG GA 31 CHAPTER 3 ENERGY EFFICIENT DESIGN OF INDUCTION MOTOR USNG GA 3.1 INTRODUCTION Electric motors consume over half of the electrical energy produced by power stations, almost the three-quarters of the

More information

APEX DYNAMICS, INC. Staianless

APEX DYNAMICS, INC. Staianless APEX DYNAMICS, INC. HIGH PRECISION PLANETARY GEARBOXES AE / AER Series Staianless High precision high speed planetary gearboxes AE / AER series Apex Dynamics, Inc. is the world s most productive manufacturer

More information

MSBCCL Series Asynchronous Three-Phase Brake Motors With Squirrel Cage Rotor Direct Current Brake

MSBCCL Series Asynchronous Three-Phase Brake Motors With Squirrel Cage Rotor Direct Current Brake NEMA MOTOR GOST MOTOR IEC MOTOR MSBCCL Series Asynchronous Three-Phase Motors ith Squirrel Cage Rotor Direct Current PUMP D.C. MOTOR GENERATOR MSBCCL series-enclosed construction externally ventilated-sizes

More information

792A AC/DC Transfer Standard

792A AC/DC Transfer Standard 92A AC/DC Transfer Standard Technical Data Support for your most demanding ac measurement requirements ppm total uncertainty Traceable to national standards range: 2 mv to 00 V Frequency range: Hz to 1

More information

Series 3000 and XE-Series Engineering Data

Series 3000 and XE-Series Engineering Data Series 3000 and XE-Series Engineering Data A C A U S T R A L I A Series 3000 and XE-Series Engineering Data The NEW era of Series 3000 and XE-Series Cooling Towers continue to exceed the industry standard

More information

Air distribution systems. Radial outlet RA-N2...

Air distribution systems. Radial outlet RA-N2... Air distribution systems Radial outlet RA-N... DS E 0.01 Radial outlet RA-N Preliminary remark KRANTZ KOMPONENTEN radial outlets RA-N have fixed radial vanes and are available with circular or square face.

More information

P U M P S. The quality standard for hydraulic efficiency and suction lift. PERIPHERAL PUMPS TEP/ TSP - SERIES 50Hz

P U M P S. The quality standard for hydraulic efficiency and suction lift. PERIPHERAL PUMPS TEP/ TSP - SERIES 50Hz P U M P S THE BENCHMARK FOR PERFORMANCE The quality standard for hydraulic efficiency and suction lift. PERIPHERAL PUMPS TEP/ TSP - SERIES 5Hz I N D E X TEP / TSP / TRP SERIES - PERIPHERAL PUMPS Page

More information

Pressure transmitters for industrial applications MBS 32 and MBS 33

Pressure transmitters for industrial applications MBS 32 and MBS 33 Data sheet Pressure transmitters for industrial applications MBS 32 and MBS 33 The standard pressure transmitters MBS 32 and MBS 33 are designed for use in almost all industrial applications, and offer

More information

GRUNDFOS DATA BOOKLET MAGNA, UPE. Series 2000 circulator pumps

GRUNDFOS DATA BOOKLET MAGNA, UPE. Series 2000 circulator pumps GRUNDFOS DATA BOOKLET MAGNA, UPE Series circulator pumps Contents Product data MAGNA and UPE 3 Duty range 3 Characteristic features 3 Benefits 3 Applications 3 eating systems 3 Pumped liquids Type key

More information

Multi-cone diffuser. Dimensions

Multi-cone diffuser. Dimensions Dimensions Vertical Ød 8 Max. H ØU ØD Horizontal Ød Description is an adjustable circular multi-cone diffuser, which is typically used for supply air. The diffuser can be switched between horizontal and

More information

DS 200P. Electronic Pressure Switch. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

DS 200P. Electronic Pressure Switch. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm accuracy according to IEC 600: standard: 0. % FSO option: 0. % FSO Nominal pressure from 0... 00 mbar up to 0... 0 bar

More information

Absolute encoders multiturn

Absolute encoders multiturn elektronischer electronic multiturn, Multiturn, magnetic magnetisch Sendix M66 / M68 (shaft / hollow shaft) The Sendix M6 with Energy Harvesting Technology is an electronic multiturn encoder in miniature

More information

Krantz. Radial slot outlet with square blade array RL-Q2... circular blade array RL-R2... Air distribution systems DS 4186 E 09.

Krantz. Radial slot outlet with square blade array RL-Q2... circular blade array RL-R2... Air distribution systems DS 4186 E 09. Krantz Radial slot outlet with square blade array RL-Q2... circular blade array RL-R2... Air distribution systems DS 86 E 09./1 with square and circular blade array Preliminary remark The radial slot outlet

More information

Chimney fan RSHT. Chimney fan RSHT. Technical data

Chimney fan RSHT. Chimney fan RSHT. Technical data Chimney fan RSHT High temperature resistant exodraft fan type RSHT is a speciay designed fue gas fan with horizonta discharge. It is fitted to the termination point of the chimney and there creating a

More information