CONFIGURABLE CROSS-FLOW HEAT RECOVERY UNITS CADB/T-N Series
|
|
- Jared Conley
- 5 years ago
- Views:
Transcription
1 FILTERS F7 Compact heat recovery unit with cross-flow heat exchanger in 9 sizes from 500 m 3 /h to m 3 /h. The casing is made from aluminium profile frame with double skinned 25 mm steel panels with mineral wool insulation. It is designed to be as compact as possible for false ceiling applications. The casings incorporate top, bottom and side access panels for maintenance. The outside skin is from PVC coated steel and the inner skin is pre-galvanised steel. The units are available in horizontal and vertical versions. pplications Public buildings, commercial offices, stores, schools and restaurants. CD/T-N D Heat recovery units without additional incorporated heater. CD/T-N DI Heat recovery units with built-in electric heater. Versions CD/T-N DC Heat recovery units with built-in hot water coil. HORIZONTL CONFIGURTION VERTICL CONFIGURTION WITHOUT DDITIONL WRMTH ELECTRIC TTERY INCLUDED WTER COIL INCLUDED Motors IP44, Class F (Models 05, 08, 45 and 55). IP20, Class F (Models 12, 18, 23 and 30). IP55, Class F (Model 80). Fans ll fans installed in CD/T-N models, comply with the efficiency requirements of the ErP Directive Filters - F7: Low pressure F7 filters for supply and extract air. Product selection software S&P air handling units selection software available. dditional information Single phase (CD-N) and three phase models (CDT-N). Horizontal and vertical version with by-pass available. Highest mounting flexibility given by the interchangeable side panels. Specific applications Heat recovery units 62 Heat recovery units CD/T-N
2 ll fans installed in CD/T-N models, comply with the efficiency requirements of the ErP Directive. Low noise level Double skinned 25 mm steel panels with mineral wool insulation. Easy mounting Single phase models with integrated mounting feets. Versions with by-pass Enables the air to by-pass the cross-flow exchanger. Filtration: - F7: Filters F7 for supply and extract air. irtight connectors Inlet and discharge connection flanges with EPDM rubber seal strip. Robust construction High quality finishing with aluminium profile and Nylon corners. Condensation drain Drain pipe to evacuate the condensate. Pressure tappings Measurement of filter contamination level. External terminal box IP65 terminal box fixed on the casing for easy wiring access. Heat recovery units CD/T-N 63
3 HIGHEST FLEXIILITY Versatile assembly The design of our heat recovery units makes it possible for the user to configure them on site. ll side panels are interchangable, which makes it possible to directly position the intake and outtake connections on site depending on the specific requirements. ll side panels are interchangable. Easy maintainance Rapid acces to the filters 05 to 30 models: easy access to filters from side and bottom.45 to 80 models: easy access to filters from side and top (except by-pass versions) Easy access for cleaning the cross-flow exchanger from top and bottom. The cross-flow exchangers are certified by EUROVENT. 64 Heat recovery units CD/T-N
4 REFERENCE C D - N D I 2 3 C H P F CD-N/CDT-N: Serie. 2 - D: Standard range. DI: Range with built-in electric heater. DC: Range with built-in hot water coil. 3 - Size. 4 - Type of configuration,, C, D, E, F. 5 - H: Horitzontal version. V: Upright version. 6 - P: Version with bypass incorporated. 7 - F7: Filters F7 for supply and extract air. TECHNICL CHRCERISTICS Models without heater Model Maximum airflow (m 3 /h) Motor power (kw) Maximum absorbed current () Speed (rpm) Protection (IP) Efficiency* (%) Sound pressure level at 3m** (d()) 230V 50Hz 230/V 50Hz Inlet Outlet Radiated CD-N D x 0,29 2 x 1, IP CD-N D x 0,3 2 x 1, IP CD-N D x 0,373 2 x 2, IP CD-N D x 0,373 2 x 2, IP ,5 66,5 49,5 CD-N D x 0,55 2 x 4, IP CD-N D x 0,55 2 x 4, IP ,5 67,5 50 CDT-N D x 1,5-2 x 10,1/5, IP CDT-N D x 1,5-2 x 10,1/5, IP CDT-N D x 2,2-2 x 8,8/5,1 913 IP * Values refering to the following conditions: Outdoor temperature -5ºC, Indoor temperature +20ºC and RH 50% / max. airflow. ** Sound pressure level in free field conditions. Models with built in electric heater Model Max. airflow (m 3 /h) Motor power (kw) Maximum absorbed current () Speed (rpm) Protection (IP) Efficiency* (%) Sound pressure level at 3m** (d()) 230V 50Hz 230/V 50Hz Inlet Outlet Radiated Power electric heater (kw) Nº Steps bsorbed current electric heater*** () CD-N DI x 0,29 2 x 1, IP Step 1 (2 kw): 8,70 CD-N DI x 0,3 2 x 1, IP ,5 2 CD-N DI x 0,373 2 x 2, IP ,5 2 CD-N DI x 0,373 2 x 2, IP ,5 66,5 49,5 6 2 CD-N DI x 0,55 2 x 4, IP CD-N DI x 0,55 2 x 4, IP ,5 67, CDT-N DI x 1,5-2 x 10,1/5, IP ,5 2 CDT-N DI x 1,5-2 x 10,1/5, IP CDT-N DI x 2,2-2 x 8,8/5,1 913 IP * Values refering to the following conditions: Outdoor temperature -5ºC, Indoor temperature +20ºC and RH 50% / max. airflow. ** Sound pressure level in free field conditions. *** In order to obtain the maximum absorbed current from the unit please add all single maximum absorbed currents (fans + steps of the electric heater). Step 1 (2 kw): 8,70 Step 2 (1,5 kw): 6,52 Step 1 (2 kw): 8,70 Step 2 (1,5 kw): 6,52 Step 1 (3 kw): 7,50 Step 2 (3 kw): 7,50 Step 1 (3 kw): 7,50 Step 2 (3 kw): 7,50 Step 1 (4,5 kw): 6,52 Step 2 (4,5 kw): 6,52 Step 1 (6 kw): 8,70 Step 2 (4,5 kw): 6,52 Step 1 (6 kw): 8,70 Step 2 (6 kw): 8,70 Step 1 (9 kw): 13,00 Step 2 (9 kw): 13,00 Power electric heater (V) phase phase phase 2-phase 2-phase 3-phase 3-phase 3-phase 3-phase Heat recovery units CD/T-N 65
5 Models with built in hot water coil (water /80ºC) Model Maximum airflow (m 3 /h) Motor power (kw) Maximum absorbed current () Speed (rpm) Protection (IP) Efficiency* (%) Sound pressure level at 3m** (d()) 230V 50Hz 230/V 50Hz Inlet Outlet Radiated Thermal Water flow performance (l/s) (kw) 80/ºC CD-N DC x 0,29 2 x 1, IP ,7 0,032 0,51 CD-N DC x 0,3 2 x 1, IP ,9 0,071 3,42 CD-N DC x 0,373 2 x 2, IP ,9 0,106 3,76 CD-N DC x 0,373 2 x 2, IP ,5 66,5 49,5 13,6 0,162 5 CD-N DC x 0,55 2 x 4, IP ,6 0,199 3,55 CD-N DC x 0,55 2 x 4, IP ,5 67, ,2 0,254 4,77 CDT-N DC x 1,5-2 x 10,1/5, IP ,5 0,365 4,97 CDT-N DC x 1,5-2 x 10,1/5, IP ,1 0,455 6,97 CDT-N DC x 2,2-2 x 8,8/5,1 913 IP ,3 0,661 4,71 * Values refering to the following conditions: Outdoor temperature -5ºC, Indoor temperature +20ºC and RH 50% / max. airflow. ** Sound pressure level in free field conditions. Pressure drop water (kpa) RECOVERY EFFICIENCY CCORDING TO THE IRFLOW Values refering to the following conditions: Outdoor temperature -5ºC. Indoor temperature +20ºC, RH 50%. Efficiency [%] CD-N 05 CD-N 08 CD-N Efficiency [%] CD-N 18 CD-N 23 CD-N qv [m 3 /h] Efficiency [%] CDT-N 45 CDT-N 55 CDT-N qv [m 3 /h] 66 Heat recovery units CD/T-N
6 RECOVERY EFFICIENCY IN DEPENDENCE OF THE OUTDOOR TEMPERTURES Model irflow m 3 /h CD-D-N CD-D-N CD-D-N CD-D-N CD-D-N CD-D-N CDT-D-N CDT-D-N CDT-D-N Indoor temperature Outdoor temperature Inlet air temperature ºC H.R. % ºC H.R. % (ºC) Minimum efficiency (%) Thermal performance (kw) , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , ,4 Heat recovery units CD/T-N 67
7 COMPLETE CHRT OF STNDRD VERSIONS CD/T-N F7 CD/T-N D HORIZONTL VERTICL CD-N D 05 CH F7 CD-N D 08 CH F7 CD-N D 12 CH F7 CD-N D 18 CH F7 CD-N D 23 CH F7 CD-N D 30 CH F7 CDT-N D 45 CH F7 CDT-N D 55 CH F7 CDT-N D 80 CH F7 CD-N D 05 CH P F7 CD-N D 08 CH P F7 CD-N D 12 CH P F7 CD-N D 18 CH P F7 CD-N D 23 CH P F7 CD-N D 30 CH P F7 CDT-N D 45 CH P F7 CDT-N D 55 CH P F7 CDT-N D 80 CH P F7 CD-N D 05 V F7 CD-N D 08 V F7 CD-N D 12 V F7 CD-N D 18 V F7 CD-N D 23 V F7 CD-N D 30 V F7 CDT-N D 45 V F7 CDT-N D 55 V F7 CDT-N D 80 V F7 CD-N D 05 V P F7 CD-N D 08 V P F7 CD-N D 12 V P F7 CD-N D 18 V P F7 CD-N D 23 V P F7 CD-N D 30 V P F7 CDT-N D 45 V P F7 CDT-N D 55 V P F7 CDT-N D 80 V P F7 CD-N D 05 V F7 CD-N D 08 V F7 CD-N D 12 V F7 CD-N D 18 V F7 CD-N D 23 V F7 CD-N D 30 V F7 CDT-N D 45 V F7 CDT-N D 55 V F7 CDT-N D 80 V F7 CD-N D 05 V P F7 CD-N D 08 V P F7 CD-N D 12 V P F7 CD-N D 18 V P F7 CD-N D 23 V P F7 CD-N D 30 V P F7 CDT-N D 45 V P F7 CDT-N D 55 V P F7 CDT-N D 80 V P F7 CD/T-N DI HORIZONTL VERTICL CD-N D 05 EV P F7 CD-N D 08 EV P F7 CD-N D 12 EV P F7 CD-N D 18 EV P F7 CD-N D 23 EV P F7 CD-N D 30 EV P F7 CDT-N D 45 EV P F7 CDT-N D 55 EV P F7 CDT-N D 80 EV P F7 CD-N DI 05 H F7 CD-N DI 08 H F7 CD-N DI 12 H F7 CD-N DI 18 H F7 CD-N DI 23 H F7 CD-N DI 30 H F7 CDT-N DI 45 H F7 CDT-N DI 55 H F7 CDT-N DI 80 H F7 CD-N DI 05 H P F7 CD-N DI 08 H P F7 CD-N DI 12 H P F7 CD-N DI 18 H P F7 CD-N DI 23 H P F7 CD-N DI 30 H P F7 CDT-N DI 45 H P F7 CDT-N DI 55 H P F7 CDT-N DI 80 H P F7 CD-N DI 05 DV F7 CD-N DI 08 DV F7 CD-N DI 12 DV F7 CD-N DI 18 DV F7 CD-N DI 23 DV F7 CD-N DI 30 DV F7 CDT-N DI 45 DV F7 CDT-N DI 55 DV F7 CDT-N DI 80 DV F7 CD-N DI 05 DV P F7 CD-N DI 08 DV P F7 CD-N DI 12 DV P F7 CD-N DI 18 DV P F7 CD-N DI 23 DV P F7 CD-N DI 30 DV P F7 CDT-N DI 45 DV P F7 CDT-N DI 55 DV P F7 CDT-N DI 80 DV P F7 CD-N DI 05 DH F7 CD-N DI 08 DH F7 CD-N DI 12 DH F7 CD-N DI 18 DH F7 CD-N DI 23 DH F7 CD-N DI 30 DH F7 CDT-N DI 45 DH F7 CDT-N DI 55 DH F7 CDT-N DI 80 DH F7 CD-N DI 05 DH P F7 CD-N DI 08 DH P F7 CD-N DI 12 DH P F7 CD-N DI 18 DH P F7 CD-N DI 23 DH P F7 CD-N DI 30 DH P F7 CDT-N DI 45 DH P F7 CDT-N DI 55 DH P F7 CDT-N DI 80 DH P F7 CD-N DI 05 FV P F7 CD-N DI 08 FV P F7 CD-N DI 12 FV P F7 CD-N DI 18 FV P F7 CD-N DI 23 FV P F7 CD-N DI 30 FV P F7 CDT-N DI 45 FV P F7 CDT-N DI 55 FV P F7 CDT-N DI 80 FV P F7 CD-N DI 05 EH F7 CD-N DI 08 EH F7 CD-N DI 12 EH F7 CD-N DI 18 EH F7 CD-N DI 23 EH F7 CD-N DI 30 EH F7 CDT-N DI 45 EH F7 CDT-N DI 55 EH F7 CDT-N DI 80 EH F7 CD-N DI 05 EH P F7 CD-N DI 08 EH P F7 CD-N DI 12 EH P F7 CD-N DI 18 EH P F7 CD-N DI 23 EH P F7 CD-N DI 30 EH P F7 CDT-N DI 45 EH P F7 CDT-N DI 55 EH P F7 CDT-N DI 80 EH P F7 CD-N DI 05 GH F7 CD-N DI 08 GH F7 CD-N DI 12 GH F7 CD-N DI 18 GH F7 CD-N DI 23 GH F7 CD-N DI 30 GH F7 CDT-N DI 45 GH F7 CDT-N DI 55 GH F7 CDT-N DI 80 GH F7 CD-N DI 05 GH P F7 CD-N DI 08 GH P F7 CD-N DI 12 GH P F7 CD-N DI 18 GH P F7 CD-N DI 23 GH P F7 CD-N DI 30 GH P F7 CDT-N DI 45 GH P F7 CDT-N DI 55 GH P F7 CDT-N DI 80 GH P F7 68 Heat recovery units CD/T-N
8 COMPLETE CHRT OF STNDRD VERSIONS CD/T-N F7 CD/T-N DC HORIZONTL VERTICL CD-N DC 05 H F7 CD-N DC 08 H F7 CD-N DC 12 H F7 CD-N DC 18 H F7 CD-N DC 23 H F7 CD-N DC 30 H F7 CDT-N DC 45 H F7 CDT-N DC 55 H F7 CDT-N DC 80 H F7 CD-N DC 05 H P F7 CD-N DC 08 H P F7 CD-N DC 12 H P F7 CD-N DC 18 H P F7 CD-N DC 23 H P F7 CD-N DC 30 H P F7 CDT-N DC 45 H P F7 CDT-N DC 55 H P F7 CDT-N DC 80 H P F7 CD-N DC 05 DV F7 CD-N DC 08 DV F7 CD-N DC 12 DV F7 CD-N DC 18 DV F7 CD-N DC 23 DV F7 CD-N DC 30 DV F7 CDT-N DC 45 DV F7 CDT-N DC 55 DV F7 CDT-N DC 80 DV F7 CD-N DC 05 DV P F7 CD-N DC 08 DV P F7 CD-N DC 12 DV P F7 CD-N DC 18 DV P F7 CD-N DC 23 DV P F7 CD-N DC 30 DV P F7 CDT-N DC 45 DV P F7 CDT-N DC 55 DV P F7 CDT-N DC 80 DV P F7 CD-N DC 05 DH F7 CD-N DC 08 DH F7 CD-N DC 12 DH F7 CD-N DC 18 DH F7 CD-N DC 23 DH F7 CD-N DC 30 DH F7 CDT-N DC 45 DH F7 CDT-N DC 55 DH F7 CDT-N DC 80 DH F7 CD-N DC 05 DH P F7 CD-N DC 08 DH P F7 CD-N DC 12 DH P F7 CD-N DC 18 DH P F7 CD-N DC 23 DH P F7 CD-N DC 30 DH P F7 CDT-N DC 45 DH P F7 CDT-N DC 55 DH P F7 CDT-N DC 80 DH P F7 CD-N DC 05 FV P F7 CD-N DC 08 FV P F7 CD-N DC 12 FV P F7 CD-N DC 18 FV P F7 CD-N DC 23 FV P F7 CD-N DC 30 FV P F7 CDT-N DC 45 FV P F7 CDT-N DC 55 FV P F7 CDT-N DC 80 FV P F7 CD-N DC 05 EH F7 CD-N DC 08 EH F7 CD-N DC 12 EH F7 CD-N DC 18 EH F7 CD-N DC 23 EH F7 CD-N DC 30 EH F7 CDT-N DC 45 EH F7 CDT-N DC 55 EH F7 CDT-N DC 80 EH F7 CD-N DC 05 EH P F7 CD-N DC 08 EH P F7 CD-N DC 12 EH P F7 CD-N DC 18 EH P F7 CD-N DC 23 EH P F7 CD-N DC 30 EH P F7 CDT-N DC 45 EH P F7 CDT-N DC 55 EH P F7 CDT-N DC 80 EH P F7 CD-N DC 05 GH F7 CD-N DC 08 GH F7 CD-N DC 12 GH F7 CD-N DC 18 GH F7 CD-N DC 23 GH F7 CD-N DC 30 GH F7 CDT-N DC 45 GH F7 CDT-N DC 55 GH F7 CDT-N DC 80 GH F7 CD-N DC 05 GH P F7 CD-N DC 08 GH P F7 CD-N DC 12 GH P F7 CD-N DC 18 GH P F7 CD-N DC 23 GH P F7 CD-N DC 30 GH P F7 CDT-N DC 45 GH P F7 CDT-N DC 55 GH P F7 CDT-N DC 80 GH P F7 Heat recovery units CD/T-N 69
9 STNDRD CONFIGURTIONS CD/T-N D/DI/DC ased on these standard configurations other configurations can be quickly adapted by the installer. INLET IR EXTRCT IR CONFIGURTIONS VERSIONS WITHOUT ELECTRIC HETER: CD/T-D HORIZONTL VERTICL Conf. CH Conf. V Conf. V Conf. EV* * Only available with by-pass. The EV version without P is obtained from V version. CONFIGURTIONS VERSIONS WITH ELECTRIC HETER: CD/T-DI and DC HORIZONTL VERTICL Conf. H Conf. DH Conf. DV Conf. EH Conf. GH Conf. FV* * Only available with by-pass. The FV version without P is obtained from V version by means of a simple modification made by the installer. 70 Heat recovery units CD/T-N
10 DIMENSIONS (mm) VERSION D - Horizontal configuration (H) Ø D C Mounting bracket (models 05, 08, 12, 18, 23 and 30) E Support feet (models 45, 55 and 80). Only location on flat surface. Model C D E Ø Weight (kg) CD-N D 05 H CD-N D 08 H CD-N D 12 H CD-N D 18 H CD-N D 23 H CD-N D 30 H CDT-N D 45 H CDT-N D 55 H CDT-N D 80 H VERSION D - Horizontal configuration (H) - With by-pass (P) Ø C Mounting bracket (models 05, 08, 12, 18, 23 and 30) D E Support feet (models 45, 55 and 80). Only location on flat surface. Model C D E Ø Weight (kg) CD-N D 05 H P CD-N D 08 H P CD-N D 12 H P CD-N D 18 H P CD-N D 23 H P CD-N D 30 H P CDT-N D 45 H P CDT-N D 55 H P CDT-N D 80 H P Heat recovery units CD/T-N 71
11 DIMENSIONS (mm) VERSION D - Vertical configuration (V) D C Ø F E Model C D E F Ø Weight (kg) CD-N D 05 V CD-N D 08 V CD-N D 12 V CD-N D 18 V CD-N D 23 V CD-N D 30 V CDT-N D 45 V CDT-N D 55 V CDT-N D 80 V VERSION D - Vertical configuration (V) - With by-pass (P) D C Ø F E Model C D E F Ø Weight (kg) CD-N D 05 V P CD-N D 08 V P CD-N D 12 V P CD-N D 18 V P CD-N D 23 V P CD-N D 30 V P CDT-N D 45 V P CDT-N D 55 V P CDT-N D 80 V P Heat recovery units CD/T-N
12 DIMENSIONS (mm) VERSION DI and DC - Horizontal configuration (H) D Ø C Mounting bracket (models 05, 08, 12, 18, 23 and 30) E Support feet (models 45, 55 and 80). Only location on flat surface. Model C D E Ø Weight (kg) CD-N DI/DC 05 H CD-N DI/DC 08 H CD-N DI/DC 12 H CD-N DI/DC 18 H CD-N DI/DC 23 H CD-N DI/DC 30 H CDT-N DI/DC 45 H CDT-N DI/DC 55 H CDT-N DI/DC 80 H VERSION DI and DC - Horizontal configuration (H) - With by-pass (P) D Ø C Mounting bracket (models 05, 08, 12, 18, 23 and 30) E Support feet (models 45, 55 and 80). Only location on flat surface. Model C D E Ø Weight (kg) CD-N DI/DC 05 H P CD-N DI/DC 08 H P CD-N DI/DC 12 H P CD-N DI/DC 18 H P CD-N DI/DC 23 H P CD-N DI/DC 30 H P CDT-N DI/DC 45 H P CDT-N DI/DC 55 H P CDT-N DI/DC 80 H P Heat recovery units CD/T-N 73
13 DIMENSIONS (mm) VERSION DI and DC - Vertical configuration (V) D C E Ø F Model C D E F Ø Weight (kg) CD-N DI/DC 05 V CD-N DI/DC 08 V CD-N DI/DC 12 V CD-N DI/DC 18 V CD-N DI/DC 23 V CD-N DI/DC 30 V CDT-N DI/DC 45 V CDT-N DI/DC 55 V CDT-N DI/DC 80 V VERSION DI and DC - Vertical configuration (V) - With by-pass (P) C D Ø F E Model C D E F Ø Weight (kg) CD-N DI/DC 05 V P CD-N DI/DC 08 V P CD-N DI/DC 12 V P CD-N DI/DC 18 V P CD-N DI/DC 23 V P CD-N DI/DC 30 V P CDT-N DI/DC 45 V P CDT-N DI/DC 55 V P CDT-N DI/DC 80 V P Heat recovery units CD/T-N
14 PERFORMNCE CURVES qv: irflow in m 3 /h. psf: Static pressure in Pa. Pabs: bsorbed power at maximum speed (W). Dry air at 20ºC and 7 mmhg. Performance data in accordance with ISO 5801 and MC Standards. dditional pressure drop Electric heater: all models 10 Pa. Hot water coils: 45Pa. p sf [Pa] 500 CD-N D/DI/DC 05 F7 p sf [Pa] 0 CD-N D/DI/DC 08 F P[W] P[W] q v [m 3 /h] q v [m 3 /h] p sf [Pa] 0 CD-N D/DI/DC 12 F7 p sf [Pa] 0 CD-N D/DI/DC 18 F V1 200 V1 V3 V P[W] q v [m 3 /h] 200 V1 V3 V2 V P[W] q v [m 3 /h] p sf [Pa] 0 CD-N D/DI/DC 23 F7 p sf [Pa] 700 CD-N D/DI/DC 30 F P[W] 200 V1 V V2 1 V q v [m 3 /h] 500 V3 V1 V2 V1 P[W] V q v [m 3 /h] Heat recovery units CD/T-N 75
15 PERFORMNCE CURVES qv: irflow in m 3 /h. psf: Static pressure in Pa. Pabs: bsorbed power at maximum speed (W). Dry air at 20ºC and 7 mmhg. Performance data in accordance with ISO 5801 and MC Standards. dditional pressure drop Electric heater: all models 10 Pa. Hot water coils: 45Pa. p sf [Pa] 800 CDT-N D/DI/DC 45 F7 p sf [Pa] 800 CDT-N D/DI/DC 55 F P[W] q v [m 3 /h] P[W] q v [m 3 /h] p sf [Pa] 700 CDT-N D/DI/DC 80 F P[W] q v [m 3 /h] 76 Heat recovery units CD/T-N
16 CCESSORIES TLE For more information see Heat recovery accessories and/or Mounting accessories. Mounting accessories supplied with a finish of galvanized sheet without painting. Model Ø (mm) FR-N (spare filter for CD/T-N) FR-N G4 FR-N M5 FR-N F7 FR-N F9 PC Inlet/outlet protection guards COPEL F N Circular flexible connector CD-N D/DI/DC FR-N-200/05 G4 FR-N-200/05 M5 FR-N-200/05 F7 FR-N-200/05 F9 PC-200 COPEL F-200/1 N CD-N D/DI/DC FR-N-250/08 G4 FR-N-250/08 M5 FR-N-250/08 F7 FR-N-250/08 F9 PC-250 COPEL F-250/1 N CD-N D/DI/DC FR-N-315/12 G4 FR-N-315/12 M5 FR-N-315/12 F7 FR-N-315/12 F9 PC-315 COPEL F-315/1 N CD-N D/DI/DC FR-N-355/18 G4 FR-N-355/18 M5 FR-N-355/18 F7 FR-N-355/18 F9 PC-355 COPEL F-355/1 N CD-N D/DI/DC FR-N-355/23 G4 FR-N-355/23 M5 FR-N-355/23 F7 FR-N-355/23 F9 PC-355 COPEL F-355/1 N CD-N D/DI/DC 30 FR-N-/30 G4 FR-N-/30 M5 FR-N-/30 F7 FR-N-/30 F9 PC- COPEL F-/1 N CDT-N D/DI/DC FR-N-450/45 G4 FR-N-450/45 M5 FR-N-450/45 F7 FR-N-450/45 F9 PC-450 COPEL F-450/1 N CDT-N D/DI/DC FR-N-500/55 G4 FR-N-500/55 M5 FR-N-500/55 F7 FR-N-500/55 F9 PC-500 COPEL F-500/1 N CDT-N D/DI/DC FR-N-630/80 G4 FR-N-630/80 M5 FR-N-630/80 F7 FR-N-630/80 F9 PC-630 COPEL F-630/1 N Model Ø (mm) SIL Circular sound attenuators SIFÓN Drain water drainage -F (Cold water) Water coils -C-N (Hot water) CD-N D/DI/DC SIL-200 SIFÓN -F 200 -C-N 200 CD-N D/DI/DC SIL-250 SIFÓN -F 250 -C-N 250 CD-N D/DI/DC SIL-315 SIFÓN -F 315 -C-N 315 CD-N D/DI/DC SIL-355 SIFÓN -F C-N 355/18 CD-N D/DI/DC SIL-355 SIFÓN -F C-N 355/23 Water temperature (80/ºC) PWW-SE1 PWW Mounting kits Water temperature (50/45ºC) PWW-SE1 PWW-SE3 CD-N D/DI/DC 30 SIL- SIFÓN -F -C-N CDT-N D/DI/DC SIL-450 SIFÓN -F 450 -C-N 450 CDT-N D/DI/DC SIL-500 SIFÓN -F 500 -C-N 500 PWW-SE3 - CDT-N D/DI/DC SIL-630 SIFÓN -F 630 -C-N 630 * Selection of the 3-way valve according to the characteristic chart (see Electrical accessories ). CCESSORIES Mounting accessories are supplied with galvanized sheet finish without painting. For more information see Heat recovery accessories. -F Cold water coil. -C-N Hot water coil. FL-N Filtration box, providedwithout filters, to mount FR-N filters (2 as a maximum). Suitable to mount outdoors. Manufactured in galvanized steel. Circular flanges with tightness joint. Cover easily removable to quickly replace the filter. Filter box Filters* FL-N FR-N G4 FR-N M5 FR-N F7 FR-N F9 FL-N-200 FR-N-200/05 G4 FR-N-200/05 M5 FR-N-200/05 F7 FR-N-200/05 F9 FL-N-250 FR-N-250/08 G4 FR-N-250/08 M5 FR-N-250/08 F7 FR-N-250/08 F9 FL-N-315 FR-N-315/12 G4 FR-N-315/12 M5 FR-N-315/12 F7 FR-N-315/12 F9 FL-N-355/18 FR-N-355/18 G4 FR-N-355/18 M5 FR-N-355/18 F7 FR-N-355/18 F9 FL-N-355/23 FR-N-355/23 G4 FR-N-355/23 M5 FR-N-355/23 F7 FR-N-355/23 F9 FL-N- FR-N-/30 G4 FR-N-/30 M5 FR-N-/30 F7 FR-N-/30 F9 FL-N-450 FR-N-450/45 G4 FR-N-450/45 M5 FR-N-450/45 F7 FR-N-450/45 F9 FL-N-500 FR-N-500/55 G4 FR-N-500/55 M5 FR-N-500/55 F7 FR-N-500/55 F9 FL-N-630 FR-N-630/80 G4 FR-N-630/80 M5 FR-N-630/80 F7 FR-N-630/80 F9 * Maximum working temperature: 70ºC. Maximum pressure lost: 250Pa. Heat recovery units CD/T-N 77
17 TPP-N Rain Protection Cowls Rain protection cowls are supplied with a finish of galvanized sheet without painting. Rain protection cowl model TPP-N Heat recovery unit model Horizontal Vertical Without by-pass With by-pass Without by-pass With by-pass CD-N D 05 TPP-N D-H 05 TPP-N D-H 05 P TPP-N D-V 05 TPP-N D-V 05 P CD-N D 08 TPP-N D-H 08 TPP-N D-H 08 P TPP-N D-V 08 TPP-N D-V 08 P CD-N D 12 TPP-N D-H 12 TPP-N D-H 12 P TPP-N D-V 12 TPP-N D-V 12 P CD-N D 18 TPP-N D-H 18 TPP-N D-H 18 P TPP-N D-V 18 TPP-N D-V 18 P CD-N D 23 TPP-N D-H 23 TPP-N D-H 23 P TPP-N D-V 23 TPP-N D-V 23 P CD-N D 30 TPP-N D-H 30 TPP-N D-H 30 P TPP-N D-V 30 TPP-N D-V 30 P CDT-N D 45 TPP-N D-H 45 TPP-N D-H 45 P TPP-N D-V 45 TPP-N D-V 45 P CDT-N D 55 TPP-N D-H 55 TPP-N D-H 55 P TPP-N D-V 55 TPP-N D-V 55 P CDT-N D 80 TPP-N D-H 80 TPP-N D-H 80 P TPP-N D-V 80 TPP-N D-V 80 P CD-N DI/DC 05 TPP-N DI/DC-H 05 TPP-N DI/DC-H 05 P TPP-N DI/DC-V 05 TPP-N DI/DC-V 05 P CD-N DI/DC 08 TPP-N DI/DC-H 08 TPP-N DI/DC-H 08 P TPP-N DI/DC-V 08 TPP-N DI/DC-V 08 P CD-N DI/DC 12 TPP-N DI/DC-H 12 TPP-N DI/DC-H 12 P TPP-N DI/DC-V 12 TPP-N DI/DC-V 12 P CD-N DI/DC 18 TPP-N DI/DC-H 18 TPP-N DI/DC-H 18 P TPP-N DI/DC-V 18 TPP-N DI/DC-V 18 P CD-N DI/DC 23 TPP-N DI/DC-H 23 TPP-N DI/DC-H 23 P TPP-N DI/DC-V 23 TPP-N DI/DC-V 23 P CD-N DI/DC 30 TPP-N DI/DC-H 30 TPP-N DI/DC-H 30 P TPP-N DI/DC-V 30 TPP-N DI/DC-V 30 P CDT-N DI/DC 45 TPP-N DI/DC-H 45 TPP-N DI/DC-H 45 P TPP-N DI/DC-V 45 TPP-N DI/DC-V 45 P CDT-N DI/DC 55 TPP-N DI/DC-H 55 TPP-N DI/DC-H 55 P TPP-N DI/DC-V 55 TPP-N DI/DC-V 55 P CDT-N DI/DC 80 TPP-N DI/DC-H 80 TPP-N DI/DC-H 80 P TPP-N DI/DC-V 80 TPP-N DI/DC-V 80 P 78 Heat recovery units CD/T-N
18 CONFIGURLE CROSS-FLOW HET RECOVERY UNITS TPP-N DIMENSIONS Rain protection cowls Rain protection cowls are supplied with galvanized sheet finish without painting. HORIZONTL CD/T-N D WITHOUT Y-PSS CD/T-N D WITH Y-PSS Model CD-N D CD-N D CD-N D CD-N D CD-N D CD-N D CDT-N D CDT-N D CDT-N D Model CD-N D CD-N D CD-N D CD-N D CD-N D CD-N D CDT-N D CDT-N D CDT-N D CD/T-N DI/DC WITHOUT Y-PSS CD/T-N DI/DC WITH Y-PSS Model CD-N DI/DC CD-N DI/DC CD-N DI/DC CD-N DI/DC CD-N DI/DC CD-N DI/DC CDT-N DI/DC CDT-N DI/DC CDT-N DI/DC Model CD-N DI/DC CD-N DI/DC CD-N DI/DC CD-N DI/DC CD-N DI/DC CD-N DI/DC CDT-N DI/DC CDT-N DI/DC CDT-N DI/DC VERTICL CD/T-N D WITHOUT Y-PSS CD/T-N D WITH Y-PSS Model CD-N D CD-N D CD-N D CD-N D CD-N D CD-N D CDT-N D CDT-N D CDT-N D CD/T-N DI/DC WITHOUT Y-PSS Model CD-N D CD-N D CD-N D CD-N D CD-N D CD-N D CDT-N D CDT-N D CDT-N D CD/T-N DI/DC WITH Y-PSS Model CD-N DI/DC CD-N DI/DC CD-N DI/DC CD-N DI/DC CD-N DI/DC CD-N DI/DC CDT-N DI/DC CDT-N DI/DC CDT-N DI/DC Model CD-N DI/DC CD-N DI/DC CD-N DI/DC CD-N DI/DC CD-N DI/DC CD-N DI/DC CDT-N DI/DC CDT-N DI/DC CDT-N DI/DC Heat recovery units CD/T-N 79
19 ELECTRICL CCESSORIES Required control elements for regulating the fan speed. For more information see Heat recovery accessories and/or Electrical accessories. Model ccessories for variable airflow by CO 2 ccessories for operation Constant Pressure Controller Sensor Controller Sensor 3 speed switch ccessories for manual speed control Electronic speed control utotransformer Variable frequency inverter CD-N D 05 CONTROL ERO-REG SC02-/SC02-D/ SC02-G CONTROL ERO-REG TDP-D - RE-5 RM-3,5 - CD-N D 08 CONTROL ERO-REG SC02-/SC02-D/ SC02-G CONTROL ERO-REG TDP-D - RE-5 RM-3,5 - CD-N D 12 CONTROL ERO-REG SC02-/SC02-D/ SC02-G CONTROL ERO-REG TDP-D COM-3 RE-10 RM-8 - CD-N D 18 CONTROL ERO-REG SC02-/SC02-D/ SC02-G CONTROL ERO-REG TDP-D COM-3 RE-10 RM-8 - CD-N D 23 CONTROL ERO-REG SC02-/SC02-D/ SC02-G CONTROL ERO-REG TDP-D COM-3 RE-10 RM-10 - CD-N D 30 CONTROL ERO-REG SC02-/SC02-D/ SC02-G CONTROL ERO-REG TDP-D COM-3 RE-10 RM-10 - CDT-N D 45 VFTM TRI 4 SC02-/SC02-D/ SC02-G VFTM TRI 4 TDP-S/TDP-D VFTM TRI 4 CDT-N D 55 VFTM TRI 4 SC02-/SC02-D/ SC02-G VFTM TRI 4 TDP-S/TDP-D VFTM TRI 4 CDT-N D 80 VFTM TRI 5,5 SC02-/SC02-D/ SC02-G VFTM TRI 5,5 TDP-S/TDP-D VFTM TRI 5,5 Heat recovery units CD/T-N DI Required control elements for managing the operation of the built-in electrical heater. Model Supply Power Steps Controller Temperature sensor External Pressure Timer* (kw) Duct sensor Room sensor potentiometer switch CD-N DI 05 Single phase 230V 2 1 Pulser TG-K330 TG-R530 TI-30 DPS 2.30 MCR-1 CD-N DI 08 Single phase 230V 3,5 2 Pulser TG-K330 TG-R530 TI-30 DPS 2.30 MCR-1 CD-N DI 12 Single phase 230V 3,5 2 Pulser TG-K330 TG-R530 TI-30 DPS 2.30 MCR-1 CD-N DI 18 Two phase V 6 2 Pulser TG-K330 TG-R530 TI-30 DPS 2.30 MCR-1 CD-N DI 23 Two phase V 6 2 Pulser TG-K330 TG-R530 TI-30 DPS 2.30 MCR-1 CD-N DI 30 Three phase V 9 2 TTC-25 TG-K330 TG-R530 TI-30 DPS 2.30 MCR-1 CDT-N DI 45 Three phase V 10,5 2 TTC-25 TG-K330 TG-R530 TI-30 DPS 2.30 MCR-1 CDT-N DI 55 Three phase V 12 2 TTC-25 TG-K330 TG-R530 TI-30 DPS 2.30 MCR-1 CDT-N DI 80 Three phase V 18 2 TTC-40 TG-K330 TG-R530 TI-30 DPS 2.30 MCR-1 * The timer has to be installed directly on the supply of the fan. HET RECOVERY UNITS WITH DDITIONL EXTERNL ELECTRIC HETER ND CCESSORIES For more information see Heating range and/or Electrical accessories. Model Connection Electric heater Electric heater Controller Duct Room External Pressure Timer with set point diameter with built-in without + sensor sensor potentiometer switch between 1 second (mm) control built-in control and hours CD-N ME-200/20T-R ME-200/20T PULSER TG-K330 TG-R530 TI-30 DPS 2.30 MCR-1 CD-N ME-250/30T-R ME-250/30T PULSER TG-K330 TG-R530 TI-30 DPS 2.30 MCR-1 CD-N ME-315/30T-R ME-315/30T PULSER TG-K330 TG-R530 TI-30 DPS 2.30 MCR-1 CD-N ME-355/T-R ME-355/T PULSER TG-K330 TG-R530 TI-30 DPS 2.30 MCR-1 CD-N ME-355/T-R ME-355/T PULSER TG-K330 TG-R530 TI-30 DPS 2.30 MCR-1 CD-N 30 ME-/T-R ME-/T PULSER TG-K330 TG-R530 TI-30 DPS 2.30 MCR-1 CDT-N ME-450/150T-R ME-450/150T TTC-25 TG-K330 TG-R530 TI-30 DPS 2.30 MCR-1 CDT-N ME-500/150T-R ME-500/150T TTC-25 TG-K330 TG-R530 TI-30 DPS 2.30 MCR-1 CDT-N TG-K330 TG-R530 TI-30 DPS 2.30 MCR-1 80 Heat recovery units CD/T-N
20 ELECTRIC CCESSORIES CONTROL ERO-REG Specific accessory to control the heat recovery units without additional incorporated heater equipped with single-phase motor (models CD-N- D 05 to 30). Not suitable for controlling the heat recovery units with built-in electric heater or heat recovery units with built-in hot water coil. Supplied as an accessory (wiring and installation not included). Functions: - On / off of recovery. - Regulation manual / automatic fan speed. - Detection of fouling of filters (it is necessary to install two switches DPS 2.30, not included with the supply of control). - Detection of damage to the fans (it is necessary to install two switches DPS 2.30, not included with the supply of control). - Modus communication Operation: - Manual potentiometer: fan speed manual control using the potentiometer located at the top. - Proportional with entry analog. fan speed control using an external probe CO 2 (accessory) humidity and temperature (0-10V / 4-20m). - Proportional Integral PI: pressure control or constant airflow when working together with CD-N ECOWTT through a differential pressure transmitter TDP-D (accessory) (0-10V / 4-20m). Model Electrical supply Maximum current () Motors output voltage IP Protection Operating temperature range Dimensions LxWxH (mm) CONTROL ERO-REG 230 VC to 230VC IP 55-10ºC to +50ºC 175x250x120 FC-REG Comparative thermostat that allows the management of the by-pass of a heat recovery unit in free-cooling mode. (pplicable to the CD/T-N range without integrated control and equipped with by-pass). It allows opening/closing of the bypass valve of the heat recovery unit on the basis of the temperatures measured by the indoor and outdoors temperature probes. Limitation of the minimum inlet air temperature adjustable to 8ºC or 12ºC. Outlet via potential free-contact. It includes two temperature probes, each one with a cable of 4m.length. Model Supply IP Frequency Voltage Protection (Hz) (V) Power (V) Outlet contact capacity () djustment range setpoint (ºC) Maximum ambient temperature (ºC) Dimensions LxxH (mm) FC-REG IP x74x26 PROSYS CD-N Remote configuration of one or more CONTROL ERO-REG. - The user can modify parameters and adjust setting values. - It is possible to connect up to 32 CONTROL ERO-REG to just one PROSYS CD-N. COM-3 3 speed switch commutator for motors 230V-1-50Hz. Maximum current: 16. Dimensions (LxWxH): 48x48x94 mm. Heat recovery units CD/T-N 81
KZPb
---------------------------------------------------------- ---------------------------------------------------------------------- Electronic constant pressure regulator FUNCTION KZP is an electronic pressure
More informationAir Cooler Industry AC-LN 1-7 / ACA-LN 2-7 / ACAF-LN 2-7
ir ooler Industry -LN -7 / -LN -7 / F-LN -7 Symbol General The -LN -7 air cooler series can be used in all areas where either oil or water-glycol is to be cooled with air. The coolers with an axial fan
More informationXHDU Cassette type fan-coils for double/four pipe connections 1,98-14 kw HYDRONIC TERMINALS
HYDRONIC TERMINALS XHDU 402 1203 Versions XHDU 2T XHDU-R 2T XHDU 4T XHDE 2T Single coil for double pipe connections Single coil for double pipe connections with heater Double coil for four pipe connections
More informationMODEL: WB009GMFI19HLD (120V) Wall Mount DC Inverter Fan Coil Unit 9,000 BTUH
MODEL: WB009GMFI19HLD (120V) Wall Mount DC Inverter Fan Coil Unit 9,000 BTUH No. Part Name Quantity BOM code List Price Remark 1 Panel assembly 1 201132890609 2 Air filter 2 201132890704 5 Display box
More informationVRF Technical Data Book
VRF Technical Data Book DVM S for Euro_ET (R4A, Hz, HP) Model : Premium (Compact / Energy Efficiency) Type Standard Type History Version Modification Date Remark Ver. 1. Release DVM S (R4A, Hz, HP) for
More informationWISE Damper. Active damper for Swegon s WISE System for demand-controlled ventilation QUICK FACTS
Active damper for Swegon s WISE System for demand-controlled ventilation QUICK FACTS Variable or constant flow regulation or constant pressure regulation Wireless communication via radio Integrated sensor
More informationALC. ALBATROSS Supply air terminal for large airflows
ALBATROSS Supply air terminal for large airflows Quick facts Large airflows Suitable for cooling or heating Manual or motorised adjustment Pressure drop independent of selected spread pattern Can be used
More informationvariable flow dampers
Constant-/ DAU, DAEU, DAVU Summary DAU - manual single flow unit DAEU - motorized twin flow unit DAVU - motorized variable flow unit Diameters Ø 0 Flow range 0 l/s ( m³/h) Pressure range Pa (over the unit)
More informationDimensions. Order code. Materials and finish. lindab ceiling diffusers
LKP Description LCP is a flush-mounted square diffuser with a circular unperforated face plate for installation in ceiling systems. LCP can be used for both supply and exhaust air. LCP is suitable for
More informationAir distribution systems. Radial outlet RA-N2...
Air distribution systems Radial outlet RA-N... DS E 0.01 Radial outlet RA-N Preliminary remark KRANTZ KOMPONENTEN radial outlets RA-N have fixed radial vanes and are available with circular or square face.
More informationPlain diffuser. Dimensions
Dimensions Ø U Ød B C Ø E Ø A Description is a circular diffuser with an unperforated adjustable face plate and can be used for both supply and extract air. The diffuser can be switched between horizontal
More informationKZMb
-------------------------------------------------------- Electronic zone controller for pressure regulation ---------------------------------------------------------------------- FUNCTION KZM is an electronic
More informationKrantz Components. Twist outlet DD-N... for ceiling installation. Air distribution systems
Krantz Components Twist outlet DD-N... for ceiling installation Air distribution systems DS E 0. Twist outlet Preliminary remarks and construction design Preliminary remarks Twist outlets for ceiling installation
More informationKSAb
--------------------------------------------------------- ---------------------------------------------------------------------- Electronic slave and constant flow regulator for air flow regulation FUNCTION
More informationEUROVENT 8/12 SOUND TEST METHOD FOR DUCTED FAN COIL UNITS. FCP 2008 testing procedures FCP acoustical test method pag. 1
EUROVENT 8/12 SOUND TEST METHOD FOR DUCTED FAN COIL UNITS FCP 2008 testing procedures FCP acoustical test method pag. 1 CONTENTS 1 - PURPOSE... 3 2 - NORMATIVE REFERENCES... 3 3 - DEFINITIONS... 3 3.1
More informationAir distribution systems. Adjustable induction outlet IN-V...
ir distribution systems djustable induction outlet IN-V... DS E 0. Construction and function Preliminary remarks In addition to its induction outlet with preset discharge direction ), KRNTZ KOMPONENTEN
More informationEXPLODED DIAGRAM - PARTS VIEW
Power Supply Sales Model: KSIL018-H216-I 208-230V~ / 1ph / 60Hz EXPLODED DIAGRAM - PARTS VIEW This information is to be used by qualify AC technicians only KSIL1816- Drawing No. D2IL16181301 Above information
More informationMulti-cone diffuser. Dimensions. Description FKD is an adjustable circular multi-cone diffuser, which is typically used for supply air.
Dimensions Vertical Ø N D F G Ø A Ø B C Horizontal Description is an adjustable circular multi-cone diffuser, which is typically used for supply air. The diffuser can be switched between horizontal and
More informationVK2 volume flow controller Overview
New option with sound attenuator Maintenance-free VK2 volume flow controller that operates without an auxiliary power supply, for ventilation and air conditioning systems. Adjustable on site. Outstanding
More informationNozzles. About Lindab. Comfort and Design. Product overview / symbols. Theory. Ceiling diffusers. Ceiling diffusers - visible.
Nozzles About Lindab Comfort and Design Product overview / symbols Theory Ceiling diffusers Ceiling diffusers - visible Plenum boxes Wall diffusers Nozzles Ventiduct Grilles Displacement diffusers VAV
More informationKSV. Slot diffusers. Ordering code. Description. Linear diffusers 1 / 16
Linear diffusers 1 / 1 KSV Slot diffusers Ordering code Number of slots Diffuser Length (mm) KSV - 1... - 19 Description KSV is an air terminal element primarily designated for air supply. It is suitable
More informationISEmax CAM40/CAS40. Technical Information
Technical Information Online measurement of nutrient parameters Ion-selective electrode system for the continuous measurement of ammonium and nitrate Application The ion-selective electrode system works
More informationGRC. Circular egg crate grille for transfer/extract air and wall/ceiling mounting QUICK FACTS
Circular egg crate grille for transfer/extract air and wall/ceiling mounting QUICK FACTS For exhaust air 91% free area Handles large airflows Cleanable Can be used with commissioning box ALS Standard colour
More informationBNA Series. PLENUM FAN with Backward Wheels
BNA Series PLENUM FAN with Backward Wheels BNA Series BNA Series Plenum Fans Backward wheels Kruger Plenum Fans are designed for air handling applications where the fan operates unhoused within a plenum.
More informationPlain diffuser. Dimensions
Dimensions ØU Ød 22 37 ØD Description is a circular diffuser with unperforated face plate and can be used for both supply and extract air. is suitable for horizontal supply of cooled air where a high impulse
More informationDirect-operated 2/2-way solenoid valves Type EV210B
Data sheet Direct-operated 2/2-way solenoid valves Type EV20B EV20B covers a wide range of direct-operated 2/2-way solenoid valves for universal use. EV20B is a very robust valve program with high performance
More informationNozzle diffuser. Dimensions
Dimensions ØU Ød H 0 ØA Description is a circular diffuser with individually adjustable nozzles. The diffuser is suitable for the horizontal supply of cooled air, where great flexibility in the dispersal
More informationTHE ENERGY 68,SAVING TDVI. exible Combine Modular 24, 26, 28, 30, 32, 34, 36, 38, 40, 42, 44 HP 60, 62, 64, 66 HP
I N V E RT E R ion Range exible Combine Modular TDV I TDV I TDV I INVERTER INVERTER INVERTER 14, 16, 18, 20, 22 HP TDV I 24, 26, 28, 30, 32, 34, 36, 38, 40, 42, 44 HP INVERTER INVERTER INVERTER TDV I INVERTER
More informationKrantz. Radial slot outlet with square blade array RL-Q2... circular blade array RL-R2... Air distribution systems DS 4186 E 09.
Krantz Radial slot outlet with square blade array RL-Q2... circular blade array RL-R2... Air distribution systems DS 86 E 09./1 with square and circular blade array Preliminary remark The radial slot outlet
More information473 Dew Point Hygrometer
High Performance Chilled Mirror Hygrometer With Cable Mounted Measuring Heads Highly precise chilled mirror dew point technology Cable mounted dew point and temperature measurement Aspirated and direct
More informationVariable swirl diffusers
Swirl diffusers, Variable swirl diffuser OD- Application Diffuser is designed for air conditioning of rooms with floor to ceiling highs of to 0 m and high induction requirements. It is suitable for large
More information473 Dew Point Hygrometer
gh Performance Chilled Hygrometer With Cable Mounted Measuring Heads ghly precise chilled mirror dew point technology Cable mounted dew point and temperature measurement Aspirated and direct insertion
More informationKrantz. RL-C2 radial slot outlet. Air distribution systems
RL-C2 radial slot outlet Air distribution systems DS E 04.1 Introduction The RL-C2 radial slot outlet with circular face generates a turbulent mixed flow. It is used for supply and return air distribution
More informationProduct Data CNPVP, CNPVT, CNPVU, CNRVU EVAPORATOR COIL N COIL - CASED AND UNCASED UPFLOW, DOWNFLOW
CNPVP, CNPVT, CNPVU, CNRVU EVPORTOR COIL N COIL - CSED ND UNCSED UPFLOW, DOWNFLOW Product Data CNPVP CNPVT (Transition) CN(P,R)VU 06008 06007 06004 This vertical design N -coil is a furnace coil designed
More informationCDD/CDR. Circular ceiling diffuser for supply air QUICK FACTS
Circular ceiling diffuser for supply air QUICK FACTS Spread pattern can be shielded Used with commissioning box ALS Cleanable Adjustable slot Perforated diffuser face = CDD Non-perforated diffuser face
More informationSECTION 1 - WHAT IS A BTU METER? BTU's = Flow x ΔT Any ISTEC BTU Meter System consists of the following main components:
SECTION 1 - WHAT IS A BTU METER? ISTEC BTU Meters measure energy usage by multiplying flow rate and temperature difference. As the water (or other liquid) passes through these lines, the multi-wing turbine
More informationAir velocity & IAQ measuring instruments
Data sheet dp Air velocity & IAQ measuring instruments - air velocity & IAQ measuring instrument - dp air velocity & IAQ measuring instrument incl. differential pressure C CO Intuitive: clearly structured
More informationSWIFT Ceiling. Square ceiling air diffuser for supply air QUICK FACTS
Square ceiling air diffuser for supply air QUICK FACTS Flush design Also available in a version for extract air. Designed for modular suspended ceilings (600 x 600 mm) Quick Access Adapter for systemized
More informationCNA-CNB. Centrifugal fans
NA-NB entrifugal fans Product facts Product Single-inlet low-pressure fans with backward-curved blades. Use In industrial ventilation systems for uncontaminated, non-corrosive air, max. 70 º, where a low
More informationB6VMAX Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS
TECHNICAL SPECIFICATIONS B6VMAX Series Air Handler with TXV 13-19 SEER Residential System 18,000-60,000 Btuh (Heat Pump & Air Conditioner) R-410A Refrigerant The B6VMAX Series of air handlers, when combined
More informationMulti-cone diffuser. Dimensions
Dimensions Vertical Ød 8 Max. H ØU ØD Horizontal Ød Description is an adjustable circular multi-cone diffuser, which is typically used for supply air. The diffuser can be switched between horizontal and
More informationAir distribution systems. Adjustable radial outlet RA-V...
Air distribution systems Adjustable radial outlet RA-V... DS E 0.2013 Construction design Preliminary remarks KRANTZ KOMPONENTEN has developed its wellknown, successful radial outlet into an adjustable
More informationAC axial compact fan
ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-767 Mulfingen Phone +9 798 8- Fax +9 798 8- info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen County court Stuttgart HRA 59
More informationMechanical flow-rate controllers
L D L D L D Mechanical flow-rate controller MRP-1 (Circular) Description With the circular air flow controllers with automated action, the air flow rate is controlled via an asymmetrical control flap pivoting
More informationAIR PREPARATION. ELECTRONICALLY CONTROLLED PRESSURE REGULATING VALVE (PROPORTIONAL PRESSURE REGULATING VALVE) SERIES control
AIR PREPARATION ELECTRONICALLY CONTROLLED PRESSRE REGLATING ALE (PROPORTIONAL PRESSRE REGLATING ALE) SERIES control Description Abb. Port size Recommended Type Data Sheet No. flow (l/min)* airfit tecno
More informationAir distribution systems. Jet nozzle DW-N2... Swivel jet nozzle DW-V2... Twist nozzle DW-V2-...-DR
Air distribution systems Jet nozzle DW-N... Swivel jet nozzle DW-V... Twist nozzle DW-V-...-DR DS E 01. Jet nozzle and twist nozzle Preliminary remarks Jet nozzle DW N Swivel jet nozzle DW V Twist nozzle
More informationSWIFTTM. Ceiling. Square ceiling air diffuser for supply air
SWIFTTM Ceiling SWIFT Ceiling Square ceiling air diffuser for supply air Quick facts Flush design Also available in a version for extract air. Designed for modular suspended ceilings (600 x 600 mm) Quick
More informationPELICAN Ceiling. Square ceiling air diffuser for supply air and extract air QUICK FACTS
Square ceiling air diffuser for supply air and extract air QUICK FACTS Flexible distribution pattern, yet the acoustic data remains the same One K-factor regardless of distribution pattern Designed for
More informationValve Supply and exhaust air
IRY Dimensions Description The valve is designed for installation at a wall or in a ceiling. It can be used for new-build and for replacement. Its smart grip function ensures an easy installation. Its
More informationIN-LINE MIXED FLOW EXTRACTOR FANS FOR DUCT MOUNTING. 14 MODELS WITH AND WITHOUT TIMERS. SAFETY AND ACOUSTIC PERFORMANCES CERTIFIED
VORTICE LINEO LONG LIFE.000 h ➀ ➀ ➁ ➁ Lineo series extractors have certified air flow, ressure (to UNI 10531:1995, corresonding to ISO 51) and noise levels (UNI EN ISO 371). Certification of these arameters
More informationAC axial compact fan
ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-7467 Mulfingen Phone +49 798 8-0 Fax +49 798 8-0 info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen County court Stuttgart HRA
More informationCDD/CDR. Single cone ceiling diffusers for supply air. Quick facts. Quick guide CDD/CDR A I R F L O W - S O U N D L E V E L
Single cone ceiling diffusers for supply air Quick facts Spread pattern can be shielded Used with commissioning box ALS Cleanable Adjustable slot Perforated diffuser face = CDD Imperforated diffuser face
More informationAC axial fan. Limited partnership Headquarters Mulfingen Amtsgericht (court of registration) Stuttgart HRA
ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-767 Mulfingen Phone +9 798 8-0 Fax +9 798 8-0 info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen Amtsgericht (court of registration)
More informationDM70 Hand-Held Dewpoint Meter for Spot-Checking Applications
DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications The Vaisala DRYCAP Hand-Held Dewpoint Meter DM70 offers accurate and fast measurement for industrial dewpoint applications, such as compressed
More informationPELICAN Ceiling HF. Square extract air diffuser QUICK FACTS
Square extract air diffuser QUICK FACTS Perforated air diffuser front face Manages large extract airflows Flush design Designed for modular suspended ceilings Quick Access front face Can be combined with
More informationBV SERIES. VERTICAL BLOWER COIL UNITS Nominal Sizes 2 thru 10 Ton
BV SERIES VERTICAL BLOWER COIL UNITS Nominal Sizes 2 thru 10 Ton MAGIC AIRE BV SERIES FAN COILS ARE ETL LISTED TO U.S. AND CANADIAN SAFETY STANDARDS AND ARE ASSEMBLED TO ORDER FOR COMPETITIVE DELIVERY.
More informationHELLA. Linear slot diffuser. Ordering codes. HELLA - Linear diffuser. Linear Diffusers 1 / 18. Example of the ordering code HELLA B-0-0-AN
Linear Diffusers / 8 HELLA Linear slot diffuser Ordering codes HELLA - Linear diffuser HELLA - Number of slots... Diffuser length L (mm) ) Increment mm... Deflector colour Damper Diffuser construction
More informationUse. Worth noting. Key figures. Installation. lindab fasadium
Contact, Overview, Index Guideline heating and cooling Plexus Professor / Professor Plus Premum / Premax / Solus Architect Polaris I & S Plafond Podium Celo Cabinett Capella Carat Atrium / Loggia Regula
More informationPARTS CATALOG. No. OBB702 REVISED EDITION-C. Models
Revision C: MXZ-3C24/3C30/4C36/5C42NA2 and MXZ-2C20/3C24/3C30NAHZ2 have been added. Please void OBB702 REVISED EDITION-B. OUTDOOR INDOOR UNIT UNIT PARTS CATALOG No. OBB702 REVISED EDITION-C Models MXZ-3C24NA
More informationAir distribution systems. Linear whirl outlet WL...
Air distribution systems Linear whirl outlet WL... DS 0 E 1.013 Preliminary remarks Mode of operation The linear whirl outlet generates turbulent mixing ventilation. It can be installed on or in a wall
More informationAir velocity & IAQ measuring instruments
Data sheet dp Air velocity & IAQ measuring instruments - air velocity & IAQ measuring instrument - dp air velocity & IAQ measuring instrument incl. differential pressure C CO Intuitive: clearly structured
More informationPELICAN Ceiling. Square ceiling air diffuser for supply air and extract air
Ceiling Square ceiling air diffuser for supply air and extract air Quick facts Flexible distribution pattern, yet the acoustic data remains the same One K-factor regardless of distribution pattern Designed
More informationALUMINIUM CENTRIFUGAL FANS. 4 x M6 x OUTLET x M6 x 20
DESCRIPTION Dutair LK-series industrial ventilators consist of a robust body made from die-cast aluminium alloy. Impellers are made of extruded aluminium. The asynchronous electric motors are maintenance
More informationPFI Closed circuit cooling towers
PFI Closed circuit cooling towers Key benefits Lowest energy consumption and total cost of ownership Year round reliable operation Ideal replacement unit with certified thermal performance PFI characteristics
More informationALUMINIUM CENTRIFUGAL FANS x M6 x x M6 x 16
LK4 DESCRIPTION Dutair LK-series industrial ventilators consist of a robust body made from die-cast aluminium alloy. Impellers are made of extruded aluminium. The asynchronous electric motors are maintenance
More informationCMA - B - C - D - CMR
Cast iron self-priming electric pumps. APPLICATIONS Pressure boosting domestic plants Small-scale irrigation Moving non-aggressive liquids for civil and industrial use Washing plants Washing vehicles CMA-B-C-D
More information473-SHX Dew Point Mirror
Humidity and Temperature Reference Hygrometer For Temperature up to 125 C Precise and stable chilled mirror dew point mirror technology High temperature optical components High temperature sample fan Cable
More informationSINGLE. Technical Data Book. Big Ceiling for Europe (R410A, 50Hz, H/P) Model : AC***JNCDEH (ODU: AC***JXAD*H)
SINGLE Technical Data Book Big for Europe (R4A, Hz, H/P) Model : AC***JNCDEH (ODU: AC***JXAD*H) History Version Modification Date Remark Ver.1. Release SINGLE Big for Europe.4.3 Ver.1.1 Modification for
More informationVD1 CLC. Small Valves DIN-range with a higher k v -value
0 EN - Small Valves DIN-range with a higher k v -value VD CLC Valve body made of brass, mat nickel-plated DN, DN 0 and DN Internally and externally threaded (Rp / R) conforming to ISO 7- Manual knob /
More informationCALEFFI. Modulating digital controller for heating and cooling. 161 series 01122/08 GB. replaces dp 01122/05
Modulating digital controller for heating and cooling series REGI ERED SI EN ISO 00:000 Cert. n FM UNI EN ISO 00:000 Cert. n 000 0/0 G replaces dp 0/0 Function The controller can be used with three-point
More informationCircular duct grille
Dimensions B+0 A+0 A B Description is a rectangular ventilation grille with vertical adjustable bars for direct installation in circular ducts. The grille can be used for both supply and exhaust air. The
More informationOUTDOOR UNITS. Introduction YMF-C. Introduction. Refrigerant
Introduction Introduction Refrigerant R407C R Series Y series (Heat Pump) R series (Air-cooling) Y series ( Only) Y series (Heat Pump) R series (Air-cooling) Y series ( Only) OUTDOOR UNITS Model Name -YMF-C
More informationSingle Phase Motors Technical Datasheets
Single Phase Motors Technical Datasheets EN A dynamic, strong and ambitious Group: Orange1 Holding is an international renown Group, one of the most important European manufacturers of single-phase and
More informationPTF30 Series. Features. Ordering information. G 6 N N F8 (0 to 5 kgf/cm 2 ) PTF30
eries Features Best pressure transmission solution for small and middle sized project such as indoor heating and air conditioning, water and sewer, or incinerator, etc. Improves noise resistance and minimize
More informationSlot diffuser. Type VSD35 2/2.6/B/3. with 35 mm wide slot
2/2.6/B/3 Slot diffuser Type VSD35 with 35 mm wide slot TROX UK Ltd Telephone +44 (0) 1842 754545 Caxton Way Telefax +44 (0) 1842 763051 Thetford e-mail trox@troxuk.co.uk Norfolk IP24 3SQ www.troxuk.co.uk
More informationCircular duct grille. Dimensions. Description. Maintenance The grille should be removed to gain access to the duct.
Dimensions B+0 A+0 A B Description RGS is a rectangular ventilation grille with vertical adjustable bars for direct installation in circular ducts. The grille can be used for both supply and exhaust air.
More informationLatest generation testo air velocity & IAQ probes with cable handle. Instruction manual
Latest generation testo air velocity & IAQ probes with cable handle Instruction manual Contents Contents 1 About this document... 5 2 Safety and disposal... 5 3 System description... 6 4 Description of
More informationELMO-G Vacuum Pumps/Compressors, Range 2BH1, Three-Phase 50 Hz
ELMO- Vacuum Pumps/Compressors, Range 2BH1, Three-Phase 50 Hz Selection diagram vacuum operation Selection diagram compressor operation The performance curves are valid for pumping air at 15 C at the inlet
More informationAIR CONDITIONER (SPLIT TYPE) SERVICE MANUAL
AIR CONDITIONER (SPLIT TYPE) SERVICE MANUAL FILE No. A10-023-1 REVISION 1 : Mar.2012 Re-edit version.( file volume down) Contents have NOT been changed. Model name: RAS-M10PKVP-E RAS-M13PKVP-E RAS-M16PKVP-E
More informationWorth noting. Introduction. Key figures. lindab architect. Picture 1. Architect Circum, Luna and Prisma.
Contact, Overview, Index Guideline heating and cooling Plexus Professor / Professor Plus Premum / Premax / Solus Architect Polaris I & S Plafond Podium Celo Cabinett Capella Carat Fasadium Atrium / Loggia
More informationENVIRONMENTALLY SOUND R 410A REFRIGERANT
ENVIRONMENTALLY SOUND REFRIGERANT N4H3 Performance Series Product Specifications EFFICIENT 13 SEER HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase,
More informationASPT Series. Multi-Position, Internal TXV. Air Handler 1½ to 5 Tons
Series Multi-Position, Internal TXV Product Features Internal factory-installed thermal expansion valves for cooling and heat pump applications Direct drive, multi-speed ECM blower motor All-aluminum evaporator
More informationGTH. Rectangular double deflection grille QUICK FACTS
Rectangular double deflection grille QUICK FACTS For supply air Adjustable air deflectors Cleanable Installed using mounting frames FHB / FHA or commissioning box TRG Available in alternative colours A
More informationIts modular concept allows to build up a ball valve for any degree of automation and any kind of application
Type 2657...59 DN 10 up to 80 mm; Plastic; 2/2 way dvantages/benefits ntegrated pilot valves, position feed-back and limit switches available Customized system solutions with Burkert valves & sensors With
More informationSupply air beam. Contact, Overview, Index. Guideline heating and cooling. Plexus. Professor / Professor Plus. Premum / Premax / Solus.
Contact, Overview, Index Guideline heating and cooling Plexus Professor / Professor Plus Premum / Premax / Architect Polaris I & S Plafond Podium Celo Cabinett Capella Carat Fasadium Atrium / Loggia Regula
More informationDOMESTIC HOT WATER PUMPS WITH FIXED-SPEED MOTOR, 3x400V AP-, AKP- and AEP- series, threaded G1/2 G1 ¼ LOREM IPSUM JE ZULT MAAR 60 HZ.
LOREM IPSUM JE ZULT MAAR HZ m Head m/s m/s m/s m/s m/s Ø m Ø Ø Ø Ø l/s Flow kw Shaft power P Ø m/h Ø 9 Ø Ø kw 9 Total input power P Ø DOMESTIC HOT WATER PUMPS WITH FIXED-SPEED MOTOR, xv AP-, AKP- and AEP-
More informationFLT5A FLT5A. abc. abc. Thermometer User Guide. Thermometer User Guide. Internet:
abc instruments international FLT5A Thermometer Land Instruments International Dronfield, S18 1DJ England Telephone: (1246) 417691 Facsimile: (1246) 41585 Email: infrared.sales@landinst.com Internet: www.landinst.com
More informationKrantz. Variable twist outlet with guide ring DD-VL... jet straightener DD-VG... Air distribution systems
Krantz Variable twist outlet with guide ring DD-VL... jet straightener DD-VG... Air distribution systems DS E 01.18 Variable twist outlet with guide ring or jet straightener Preliminary remarks The variable
More informationCapaciTorr HV 200 HIGHLIGHTS
CapaciTorr HV 200 General Features High pumping speed for all active gases High sorption capacity and increased lifetime Costant pumping speed in HV, UHV and XHV Reversible pumping of hydrogen and its
More information3 Port, 2-Ton Outdoor Heat Pump
Job Name: Tag# Submittal Data Sheet 3 Port, 2-Ton Outdoor Heat Pump 3MXS24NMVJU Efficiency SEER EER HSPF Non-Ducted 17.9 12.7 12.5 Ducted 14 9.7 8.2 Mixed 15.95 11.2 10.35 Performance Cooling (Btu/hr)
More informationSlot diffusers. Slot diffusers, Round duct diffusers. Slot diffusers. Slot diffusers LD-13, LD-14
, Round duct diffusers D-, D- Application D- and D- slot diffusers are designed for the supply of air in rooms with floor to ceiling heights of.5 to m for supplying either cold or warm air, in particular
More informationALUMINIUM CENTRIFUGAL FANS. 4 x M6 x 16
DESCRIPTION Dutair BCT-series aluminium centrifugal fans with open die-cast aluminium impellers and forward curved blades are suitable for material transport and high pressure applications. The asynchronous
More informationKM-2000SWE3 KM-2000SRE3
NO. ISSUED: REVISED: 71090 JUNE 7, 1994 AUG. 7, 2000 HOSHIZAKI STACKABLE CRESCENT CUBER MODEL KM-2000SWE3 KM-2000SRE3 (FINAL) PARTS LIST KM-2000SWE3 D-0 June, 1994 E-1 April, 1995 F-1 May, 1996 F-2 July,
More informationALUMINIUM CENTRIFUGAL FANS M20 4 x M5 x 10 INLET. 4 x M5 x 12
BCT61 DESCRIPTION Dutair BCT-series aluminium centrifugal fans with open die-cast aluminium impellers and forward curved blades are suitable for material transport and high pressure applications. The asynchronous
More informationIBV Series Z Alloy Steel Inverted Bucket Vertical Steam Trap
Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without
More informationSTATIC GAS MONITOR Type SGM/DEW Revision A of 20 aprile 2016
APPLICATIONS Moisture monitoring of air or gas (SF6) Suitable for indoor or outdoor Industrial, medical or aerospace fields HIGHLIGHTS High voltage circuit breakers commonly used for distribution and transmission
More informationIBV Series C Carbon Steel Inverted Bucket Vertical Steam Trap
Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without
More informationAXO adjustable vanes swirl diffusers
klin SYSTEM XO adjustable vanes swirl diffusers M DEL The XO swirl diffusers are designed to be applied in air conditioning ventilation and heating systems.they can be mounted in false ceilings or suspended
More informationMR medium rating busbar
technical information General features MR is fully compliant with S EN 0-, specifically, the rated current of the Zucchini busbar trunking systems is always rated at the average ambient temperature of
More informationSINGLE IMPELLER CENTRIFUGAL ELECTRIC PUMPS in cast iron
Cast iron self-priming electric pumps. APPLICATIONS Pressure boosting domestic plants Small-scale irrigation Moving non-aggressive liquids for civil and industrial use Washing plants Washing vehicles CMA-B-C-D
More information