Submersible Pump in Discharge Tube. Amacan K. 60 Hz. Type Series Booklet

Size: px
Start display at page:

Download "Submersible Pump in Discharge Tube. Amacan K. 60 Hz. Type Series Booklet"

Transcription

1 Submersible Pump in Discharge Tube Amacan K Hz Type Series Booklet

2 Legal information/copyright Type Series Booklet Amacan K All rights reserved. The contents provided herein must neither be distributed, copied, reproduced, edited or processed for any other purpose, nor otherwise transmitted, published or made available to a third party without the manufacturer's express written consent. Subject to technical modification without prior notice. KSB Aktiengesellschaft, Frankenthal 12/12/17

3 Contents Contents Water Applications: Water Transport Amacan K... 4 Fluids handled... 4 Main applications... 4 Operating data... 4 Designation... 4 Design details... 4 Materials... Coating and preservation... Product benefits... 6 Acceptance tests and warranty... 6 Selection information... 6 Overview of product features / selection tables... 7 Overview of product features... 7 Impeller... 8 Table of fluids handled... 8 Motor sizes per pump... 9 Related documents... Specifications required for inquiries/orders... Selection chart Amacan K, n = 11 / 8 / rpm Characteristic curves n = 11 rpm Amacan K -/8-, n = 11 rpm Amacan K -71/8-71, n = 11 rpm... 1 Amacan K 8-, n = 11 rpm Amacan K 8-1, n = 11 rpm... 1 n = 8 rpm Amacan K -24/8-24, n = 8 rpm Amacan K -, n = 8 rpm Amacan K -71/8-71, n = 8 rpm Amacan K 8-, n = 8 rpm Amacan K 8-, n = 8 rpm... Amacan K 8-1, n = 8 rpm Amacan K -4, n = 8 rpm Amacan K -, n = 8 rpm... 2 Amacan K -, n = 8 rpm n = rpm... 2 Amacan K -, n = rpm... 2 Amacan K -, n = rpm Dimensions Motor version UE, XE [inch] Motor version UE, XE [mm]... Motor version UN, XN [inch]... Motor version UN, XN [mm]... Types of installation... 8 Scope of supply... 8 Accessories... 9 Pump set with support rope and turnbuckle in the discharge tube... 9 Discharge tube cover with cable gland... Design: with welding sleeve... Design variant with transit frame (up to 1 bar) General assembly drawings with list of components Motor version UE, XE Motor version UN, XN... 4

4 Water Applications: Water Transport Amacan K Designation Example: Amacan K 8- / 8 UN G - IE Key to the designation Code Amacan K Description Type series Impeller type K Channel impeller 8 Nominal diameter of the discharge tube [mm] Nominal impeller diameter [mm] Motor size 8 Number of motor poles UN Motor version UE/UN Without explosion protection XE/XN Explosion-proof to NEC G Material variant G Impeller made of gray cast iron, standard design G1 Like G, with impeller made of duplex stainless steel IE Motor efficiency classification 1) - 2) No efficiency classification IE Premium Efficiency Fluids handled Waste water Sludge Surface water Stormwater Gray water Main applications Irrigation pumping stations Drainage pumping stations Stormwater pumping stations Water pollution control Flood control Operating data Operating properties Characteristic Value Flow rate Q [US.gpm] 2 Q [m /h] Head H [ft] 8 H [m] 24,4 Motor rating P 2 [hp] P 2 [kw] 261 Fluid temperature T [ F] 4 T [ C] + Design details Design Fully floodable submersible pump in discharge tube (submersible motor pump) Not self-priming Close-coupled design Single-stage Vertical installation Installation types Application-oriented installation types ( Page 8) Drive Three-phase asynchronous squirrel-cage motor Version with explosion protection to NEC : Explosionproof for Class I, Division 1, Groups C and D, T, hazardous (classified) locations. Shaft seal Two bi-directional mechanical seals in tandem arrangement, with liquid reservoir Impeller type Application-oriented impeller type Bearings Motor version UE, XE: Drive end: 1) IEC 4- standard not binding for submersible motor pumps. Efficiencies calculated/determined according to the measurement method specified in IEC 4-2. The marking is used for submersible motors that achieve efficiency levels similar to those of standardized motors acc. to the IEC 4- standard. 2) Blank 4 Amacan K

5 Grease-packed bearings sealed for life Maintenance-free Pump end: Grease-packed bearings sealed for life Maintenance-free Motor version UN, XN: Drive end: Grease-packed bearings sealed for life Maintenance-free Pump end: Can be re-lubricated Materials Other designs on request Overview of materials depending on material variant Part No. Description Material variant G G1 1 Pump casing A 48 Class B 16 Discharge cover A 48 Class B Impeller A 48 Class B A 89 CD 4 MCu / Bearing housing / bearing bracket A 48 Class B 412 O-ring NBR ) (Viton FPM) 4) 4 Mechanical seal (pump end) SiC/SiC (bellows NBR ), Viton - FPM) 4) ) Mechanical seal (drive end) Carbon / SiC (bellows NBR ), Viton - FPM) 4) ) 2 Casing wear ring A 48 Class B / AISI 29 ) 71 Bail A6 -- / A 6: --18 /A 284 B 6) 811 Motor housing A 48 Class B 812 Motor housing cover A 48 Class B 7) 818 Rotor A 276 Type 4 / A 76 Gr. 4 ( Page 7) 84 Cable gland - Cable gland housing A 48 Class B Various Screws/bolts Stainless steel Comparison of materials EN ASTM EN-GJL-2 (JL ) A 48 Class B A 89 CD 4 MCu 1.21 A 276 Type 4 C 4 + N A 76 Gr. 4 EN ASTM VG 44 AISI 29 NBR NBR FPM FKM EN-GJS--1 A 6: --18 EN-GJS--7 A 6: -- S2JR A 284 B Gray cast iron EN-GJL-2 (lamellar graphite cast iron): Lamellar graphite cast iron to EN 161 is the most widely used cast material for handling municipal sewage, waste water and sludges as well as stormwater and surface water. It is suitable for neutral fluids which are only slightly aggressive and cause little wear. The ph value should be 6., the sand content. g/l. Duplex stainless steel (1.417 or technically equivalent material) This type of cast steel is resistant to cavitation, has excellent strength values and is used for high circumferential speeds. An excellent resistance to pitting corrosion makes ferritic-austenitic stainless steel a popular choice for pumping acidic waste water with a high chloride content as well as seawater and brackish water. Thanks to its good chemical resistance, e.g. against waste water containing phosphorus and sulphuric acid, this material is used in a wide range of applications in the chemical industry and process engineering. Pumps made of duplex stainless steel have a very long service life, even when handling brines, chemical waste water (ph 1-12), gray water and landfill leachate. Coating and preservation Paint Surface treatment: SA 2 1/2 (SIS 9) AN 18 Primer: primer coat on unfinished casting Top coat: environmentally friendly KSB standard coating (RAL 2) Special coating Available on request (extra charge and a longer delivery period apply). ) Nitrile rubber (Perbunan) 4) FPM fluorocarbon rubber variant available as an option against a surcharge ) This option is available against a surcharge. 6) A6 -- for motors 226, 6,118 to 228; A for motors 16 to 86, 8 to 8, to 9; A284B for motors 18 to 8, 1 to 1 7) Not available for all sizes Amacan K

6 Product benefits Efficient use of power thanks to three-phase motor and optimum motor cooling by fluid handled. The pump s own weight ensures self-centering seating in the discharge tube, and an O-ring seals it; quick to install or remove without additional anchoring or anti-rotation device. Slim motor minimizes discharge tube flow losses. High reliability thanks to bearing temperature monitoring, vibration sensor, thermal motor protection, leakage sensors in the motor space and connection space as well as leakage monitoring of the mechanical seal system. Low-vibration hydraulic system; inlet ribs and optimized bellmouth for vortex-free inflow. Absolutely water-tight resin-sealed cable entries prevent any water from entering the motor even in the event of a damaged connection cable. Acceptance tests and warranty Functional test Every pump undergoes functional testing to KSB standard ZN. Operating data is guaranteed to DIN EN ISO 996/2/2B or Hydraulic Institute Level B. Acceptance tests Acceptance testing to ISO/DIN or comparable standards is available against a surcharge. Warranty Quality is assured by means of an audited and certified quality assurance system to DIN EN ISO 91. Selection information Information for pump selection The guaranteed point of submersible pumps in discharge tubes is measured at a head of 1. ft [. m] above the motor. The documented characteristic curves refer to this data. This must be taken into account when calculating system losses. The indicated heads and performance data apply to pumped fluids with a density ρ = 7.48 lbs/ft [1 kg/dm ] and a kinematic viscosity ν of up to mm 2 /s. Adjust the power input to the density of the fluid handled: P 2 (required) = ρ [kg/dm ] (fluid handled) P 2 (documented) Select the operating point with the largest power input within an operating range. Select a motor size providing a power reserve to compensate for the tolerances in the system characteristic / pump characteristic. Determine the minimum water level t 1min (diagram in general arrangement drawing): The minimum water level t 1min is the water level required in the pump's suction chamber to ensure the following: The hydraulic system (impeller) is sufficiently submerged (shown in diagram depending on pump size). The pump does not draw in air-entraining vortices (shown in diagram depending on flow rate). The hydraulic system is free from cavitation (check against the NPSH required value in the technical literature. The following conditions must be met: NPSH available > NPSH required + safety margin NPSH available =. + (t 1 - t 2 ) Safety margin: up to Q opt 1. ft [. m] larger than Q opt. ft [1. m] Head (H) The total pump head is composed as follows: H = H geo + Δ H V H geo (static head) Without discharge elbow Difference between suctionside water level and overflow edge With discharge elbow Difference between suction-side and discharge-side water level Δ H V (losses in the system) Starting 1. ft [. m] downstream of the pump: e.g. pipe friction, elbow, swing check valve, etc. Inlet losses, riser and elbow losses Losses are caused by the inlet, riser and elbow (and/or free discharge). Losses in the riser up to the indicated reference level (1. ft [. m] above the motor) are taken into account in the documented characteristic curves. Inlet losses and elbow losses are system losses. These losses must be taken into account for selection. For information on structural requirements, pump installation and pump sump design please refer to the KSB know-how brochure "Planning Information: Amacan Submersible Pumps in Discharge Tubes" Recommended motor power reserve 8) P 2 Reserve [hp] [kw] Mains operation With frequency inverter % 1 % > > % % 8) If larger power reserves are stipulated by local regulations, these larger reserves must be provided. 6 Amacan K

7 Overview of product features / selection tables Overview of product features Overview of product features Feature Motor version UE/XE UN/XN Motor size 6-pole 22 6, to pole 11 8 to to to 8 -pole to 1 Material Shaft A 276 Type 4 (1.21) Shaft protecting sleeve - A 276 Type 4 (1.21) Storage Grease-packed rolling element bearings sealed for life Pump end: re-greasable rolling element bearing Drive end: grease-packed rolling element bearing sealed for life Explosion protection Motor version UE, UN Not explosion-proof Motor version XE, XN or Explosion-proof Class I, Division 1, Groups C & D, T Motor Starting method DOL or star-delta starting Electrical voltage 4 V 9) Cooling Cooled by surrounding fluid Maximum immersion depth ft [ m] max. Power cable Type See the "Overview of power cables table Length ft [ m] ) Cable entry Absolutely watertight Sealing elements Elastomer seals Nitrile butadiene rubber NBR 11) Shaft seal Bellows-type mechanical seal 12) Monitoring equipment Winding temperature, motor Temperature switch (bimetal) in the winding version UE, UN Winding temperature, motor Temperature switches (bimetal) in the winding, plus PTC thermistors for explosion protection version XE, XN Bearing temperature - - 1) Pt resistance thermometer on pump end 14) Motor leakage Electrode monitoring the winding space for leakage Electrode monitoring the winding space and connection space for leakage Mechanical seal leakage - Float switch in leakage area Vibration sensor - - 1) Coating Environmentally friendly KSB standard coating, color RAL 2 16) Installation ( Page 8) Maximum fluid temperature 4 F [ C] Tests/inspections Hydraulic system KSB standard (ZN 2) 17) General KSB standard (ZN 2) 9) Optional: V, 8 V, V ) Optional: up to 1 ft [ m] 11) Optional: Viton = fluorocarbon rubber FPM 12) Optional: mechanical seal with covered spring 1) Optional: Pt resistance thermometer on pump end 14) Optional: Pt resistance thermometer on motor end 1) Optional: internal vibration sensor 16) Optional: 2 μm 17) Optionally to ISO 996/1/2/A Amacan K 7

8 Overview of power cables Feature S1BN8-F rubber-sheathed cable S7RC4N8-F rubber-sheathed cable Type Standard Optional Rated voltage V V EMC screening - Insulation material EPR 18) EPR 18) Max. continuous temperature of insulation 194 F [9 C] 194 F [9 C] For permanent immersion in waste water to DIN VDE /HD22.16 Impeller Closed multi-channel impeller (impeller type K) Table of fluids handled The table below for your guidance is based on KSB's long-standing experience. The data are standard values and are not to be considered as generally binding recommendations. More detailed advice is available from KSB. Make use of our laboratory's expertise when selecting materials. Fluid handled 19) (fluids not containing stringy substances) Gray water River water Stormwater Waste water Information, recommendations Free passage > any solids contained, possibly pre-cleaned via a screen or weir Pre-cleaned via a screen or weir Activated sludge Pumpable up to a dry substance content of: % Industrial waste water containing - Paint suspensions Solvent-free, observe the operator's instructions. - Lacquer/paint/varnish suspensions Solvent-free, contact KSB to handle silicone-free fluids. - Fibers/pulp Fluids containing short fibers, no stringy material - Chips/swarf Material variant G1, special mechanical seal, solids content < g/l - Abrasive substances Mildly acidic industrial waste water ph value 6.: material variant G1 and special coating ph value < 6.: contact KSB (for material variant C) Neutral non-corrosive waste water - Ammonium hydroxide - Ammonium hydroxide % NH 4 OH - Urea 2 % NH 2 -CO - Potassium hydroxide % KOH - Calcium hydroxide % Ca(OH) 2 - Sodium hydroxide % NaOH - Sodium carbonate % Na 2 CO Neutral, non-corrosive waste water containing - Aliphatic hydrocarbons, e.g. oils, petrol, butane, methane - Aromatic hydrocarbons, e.g. benzene, styrene FPM (Viton) O-rings; for high concentrations contact KSB. - Chlorinated hydrocarbons, e.g. tetrachloroethylene, ethylene chloride, chloroform, methylene chloride 18) EPR = ethylene propylene rubber 19) Fluids to be pumped which are not listed in this table require higher-grade materials. Contact KSB. 8 Amacan K

9 Motor sizes per pump Overview of motor sizes per pump Size Motor 6-pole 8-pole -pole 22 6.E 6.E 1 6.E 7 6.E 4 6.E 6.E 6.N 8 6.N 6.N 1 6.N 1 6.N 1 6.N 19 6.N 22 6.N 2 6.N 6.N 6.N 6.N 4 6.N E 1 8.E 18 8.E 22 8.E 8.E 7 8.E 4 8.E 8.N 8.N 8.N 9 8.N 1 8.N 8.N 1 8.N 18 8.N 2 8.N 2 8.N 8.N 8.N.N.N.N 9.N 1.N 1.N 1 General assembly drawing Amacan K, motor version UE, XE 2 General assembly drawing Amacan K, motor version UN, XN Water Applications: Water Transport Amacan K 9

10 Related documents General Arrangement Drawings Motor Data Booklet Planning Information 118. Specifications required for inquiries/orders Designation of the pump ( Page 4) Flow rate Q, head H total Type of fluid handled and fluid temperature Voltage, frequency, starting method, cable length Quantity and language of operating manuals Required accessories For discharge tubes indicate all required elevations and the type of installation. For flow-straightening vanes indicate the type of installation and design (with or without suction umbrella). For a support rope indicate dimension "L", the number of additional lifting rings (depending on the lifting height of the lifting equipment) as well as the elevations and type of installation. Always define dimension "L" when ordering a support rope to allow the correct length to be determined. The lifting height of the crane must be taken into account when ordering a support rope. This determines the number of lifting rings required for installing the pump set in or removing it from the discharge tube. 1 2 L 4 1 Suspension arrangement attached to cover (or cross beam for installation type BU) 2 Lifting ring (standard, included in the scope of supply) Optional (intermediate) lifting ring 4 Lower edge of discharge tube The support rope is an accessory and can be supplied with additional lifting rings and a support spacer as an option. The standard design is supplied without intermediate lifting ring. ( Page 9) Amacan K

11 Selection chart Amacan K, n = 11 / 8 / rpm US.gpm IM.gpm K8-6p K8-1 6p K- 8p K- 8p K-71 6p K-4 8p K- 6p K8-8p K8-8p K- p K- p K/8-71 8p K-24 8p 4 K/8-8p K8-1 8p Amacan K 11 2 H [m] 1 Q[m³/h] l/s 4 ft Water Applications: Water Transport

12 Characteristic curves n = 11 rpm Amacan K -/8-, n = 11 rpm Characteristic curves to ISO 996 / 2 / 2B. The characteristic curves correspond to the effective motor speed. Q [US.gpm] Q [IM.gpm] η [%] 77 H [ft] H [m] ø26/a1 ø/296/292/2 /A6 ø287/266/2/11 /A6 ø2/242/2/1 /A6 Q [m³/h] 8 1 NPSH [m] 9 Qmin Q [l/s] ø287/266/2/11 /A6 ø2/242/2/1 /A6 ø/296/292/2 /A6 ø26/a1 NPSH [ft] 2 P [kw] P [hp] ø26/a1 ø/296/292/2 /A6 ø287/266/2/11 /A6 ø2/242/2/1 /A6 Q [m³/h] 8 1 K4227/1 Free passage = 2 / 4 [ mm] Rated power P 2 and mass moment of inertia J ) Size Motor P 2 J [hp] [kw] [kgm 2 ] UE/XE, 22,,4-6 UE/XE,,, UE/XE - IE 2, 18,,82 Size Motor P 2 J [hp] [kw] [kgm 2 ] UE/XE, 7,, UE/XE - IE,,,9 8-6 UE/XE - IE, 7, 1, ) These values are valid for a density = 1 kg/dm³ and a kinematic viscosity of up to mm²/s. 12 Amacan K

13 Amacan K -71/8-71, n = 11 rpm Characteristic curves to ISO 996 / 2 / 2B. The characteristic curves correspond to the effective motor speed. Q [US.gpm] Q [IM.gpm] 1 H [m] NPSH [m] Qmin η [%] ø/a1 ø/a1 ø2/a1 ø/278/2/1 /A6 ø19///6. /A6 Q [m³/h] 8 1 Q [l/s] ø/278/2/1 /A6 ø19///6. /A6 ø2/a1 ø/a1 ø/a1 H [ft] NPSH [ft] P [kw] ø/a1 ø/a1 P [hp] ø/278/2/1 /A6 ø2/a1 ø19///6. /A6 Q [m³/h] 8 1 K417/ Free passage = 4 1 / 8 [ mm] Rated power P 2 and mass moment of inertia J 21) Size Motor P 2 J [hp] [kw] [kgm 2 ] UE/XE, 22,, UE/XE,,, UE/XE - IE 2, 18, 1, UE/XE, 7, 1, UE/XE - IE, 22, 1, UE/XE, 4, 1, UE/XE - IE,, 1, UE/XE - IE, 7, 1, 21) These values are valid for a density = 1 kg/dm³ and a kinematic viscosity of up to mm²/s. Amacan K 1

14 Amacan K 8-, n = 11 rpm Characteristic curves to ISO 996 / 2 / 2B. The characteristic curves correspond to the effective motor speed. Q [US.gpm] Q [IM.gpm] H [m] NPSH [m] Qmin Q [m³/h] 8 1 Q [l/s] η [%] ø/a1 ø/a1 ø18/// /A6 ø/29/29/7. /A6 ø18/// /A6 ø/29/29/7. /A6 8 ø/a1 ø/a1 H [ft] NPSH [ft] P [kw] ø/a1 P [hp] ø/a1 ø18/// /A6 ø/29/29/7. /A6 Q [m³/h] 8 1 K4174/ Free passage = / 8 [8 mm] Rated power P 2 and mass moment of inertia J 22) Size Motor P 2 J [hp] [kw] [kgm 2 ] UE/XE, 22,, UE/XE,,, UE/XE, 7,, UE/XE - IE, 22,, UE/XE, 4, 1, UE/XE - IE,, 1, 8-6 UE/XE 74,, 1,1 8-6 UE/XE - IE, 7, 1, UN/XN - IE, 4, 1, 22) These values are valid for a density = 1 kg/dm³ and a kinematic viscosity of up to mm²/s. 14 Amacan K

15 Amacan K 8-1, n = 11 rpm Characteristic curves to ISO 996 / 2 / 2B. The characteristic curves correspond to the effective motor speed. 8 Q [US.gpm] 8 Q [IM.gpm] η [%] H [ft] H [m] ø8/9/76/6 ø98/71/47/11 ø84//27/14 ø67/1/27/14 Q [m³/h] 1 2 NPSH [m] Qmin Q [l/s] ø98/71/47/11 ø84//27/14 ø67/1/27/14 ø8/9/76/6 NPSH [ft] 8 P [kw] P [hp] ø8/9/76/6 ø98/71/47/11 ø67/1/27/14 ø84//27/14 Q [m³/h] 1 2 K4177/ Free passage = [1 mm] Rated power P 2 and mass moment of inertia J 2) Size Motor P 2 J [hp] [kw] [kgm 2 ] UE/XE, 7, 1, UE/XE, 4, 1, UE/XE 74,, 1, UN/XN 8,, 1, UN/XN - IE, 7, 1, UN/XN 7, 8, 1, UN/XN - IE, 4, 1, 2) These values are valid for a density = 1 kg/dm³ and a kinematic viscosity of up to mm²/s. Amacan K 1

16 n = 8 rpm Amacan K -24/8-24, n = 8 rpm Characteristic curves to ISO 996 / 2 / 2B. The characteristic curves correspond to the effective motor speed. Q [US.gpm] 12 Q [IM.gpm] Qmin H [ft] 8 6 H [m] η [%] ø24/a1 ø9/294/29/8 /A6 ø29/262/2/1 /A6 Q [m³/h] 8 Q [l/s] ø29/262/2/1 /A6 ø9/294/29/8 /A6 ø24/a1 NPSH [m] NPSH [ft] 1 P [kw] ø24/a1 P [hp] 1 ø9/294/29/8 /A6 ø29/262/2/1 /A6 Q [m³/h] 8 K4218/1 Free passage = 2 / 4 [ mm] Rated power P 2 and mass moment of inertia J 24) Size Motor P 2 J [hp] [kw] [kgm 2 ] UE/XE 1, 11,, UE/XE, 1,, UE/XE 2, 18,, UE/XE - IE 1, 11,, UE/XE - IE, 1,, UE/XE - IE 2, 18,,92 24) These values are valid for a density = 1 kg/dm³ and a kinematic viscosity of up to mm²/s. 16 Amacan K

17 Amacan K -, n = 8 rpm Characteristic curves to ISO 996 / 2 / 2B. The characteristic curves correspond to the effective motor speed. Q [US.gpm] Q [IM.gpm] 12 Qmin H [ft] H [m] η [%] ø26/a1 ø/296/292/2 /A6 ø287/266/2/11 /A6 ø2/242/2/1 /A6 Q [m³/h] 8 Q [l/s] ø/296/292/2 /A6 ø287/266/2/11 /A6 ø2/242/2/1 /A6 ø26/a1 18 NPSH [ft] NPSH [m] P [hp] P [kw] ø26/a1 ø/296/292/2 /A6 ø287/266/2/11 /A6 ø2/242/2/1 /A6 2 Q [m³/h] 8 K42188/1 Free passage = 2 / 4 [ mm] Rated power P 2 and mass moment of inertia J 2) Size Motor P 2 J [hp] [kw] [kgm 2 ] UE/XE 1, 11,,4-1 8 UE/XE, 1,,4-1 8 UE/XE - IE, 7,, UE/XE - IE 1, 11,, UE/XE - IE, 1,,6 2) These values are valid for a density = 1 kg/dm³ and a kinematic viscosity of up to mm²/s. Amacan K 17

18 Amacan K -71/8-71, n = 8 rpm Characteristic curves to ISO 996 / 2 / 2B. The characteristic curves correspond to the effective motor speed. 12 H [m] NPSH [m] Q [US.gpm] Q [IM.gpm] Qmin 7 7 η [%] ø/a1 ø/a1 ø2/a1 ø/278/2/1 /A6 ø19///6. /A6 Q [m³/h] 8 Q [l/s] ø19///6. /A6 ø/278/2/1 /A6 ø/a1 ø2/a1 ø/a1 H [ft] NPSH [ft] 2 1 P [kw] ø/a1 ø/a1 P [hp] ø2/a1 ø19///6. /A6 ø/278/2/1 /A6 Q [m³/h] 8 K42189/1 Free passage = 4 1 / 8 [ mm] Rated power P 2 and mass moment of inertia J 26) Size Motor P 2 J [hp] [kw] [kgm 2 ] UE/XE 1, 11,, UE/XE, 1,, UE/XE - IE, 7,, UE/XE 2, 18,, UE/XE - IE 1, 11,, UE/XE - IE, 1,, UE/XE - IE 2, 18, 1,2 26) These values are valid for a density = 1 kg/dm³ and a kinematic viscosity of up to mm²/s. 18 Amacan K

19 Amacan K 8-, n = 8 rpm Characteristic curves to ISO 996 / 2 / 2B. The characteristic curves correspond to the effective motor speed. Q [US.gpm] Q [IM.gpm] 1 8 η [%] H [ft] H [m] ø/a1 ø/a1 ø18/// /A6 ø/29/29/7. /A6 Q [m³/h] 8 NPSH [m] 8 Qmin Q [l/s] ø/29/29/7. /A6 ø/a1 ø18/// /A6 ø/a1 NPSH [ft] 1 1 ø/a1 P [kw] ø/a1 P [hp] ø18/// /A6 ø/29/29/7. /A6 Q [m³/h] 8 K41/ Free passage = / 8 [8 mm] Rated power P 2 and mass moment of inertia J 27) Size Motor P 2 J [hp] [kw] [kgm 2 ] UE/XE 1, 11,, UE/XE, 1,, UE/XE 2, 18,, UE/XE - IE 1, 11,, UE/XE, 22,, UE/XE - IE, 1,, UE/XE - IE 2, 18,, UE/XE - IE, 22, 1, 27) These values are valid for a density = 1 kg/dm³ and a kinematic viscosity of up to mm²/s. Amacan K 19

20 Amacan K 8-, n = 8 rpm Characteristic curves to ISO 996 / 2 / 2B. The characteristic curves correspond to the effective motor speed. 8 Q [US.gpm] 8 Q [IM.gpm] 1 Qmin H [m] NPSH [m] ø8/a1 ø88/77/67/. /A6 ø76/8/4/8. /A6 ø/4// /A6 ø2//292/14. /A6 Q [m³/h] 1 Q [l/s] η [%] 8.2 ø88/77/67/. /A6 ø76/8/4/8. /A6 ø/4// /A6 ø2//292/14. /A6 79 ø8/a1 H [ft] NPSH [ft] P [kw] ø8/a1 ø88/77/67/. /A6 ø76/8/4/8. /A6 P [hp] ø/4// /A6 ø2//292/14. /A6 Q [m³/h] 1 K4176/ Free passage = 1 [ mm] Rated power P 2 and mass moment of inertia J 28) Size Motor P 2 J [hp] [kw] [kgm 2 ] UE/XE 2, 18,, UE/XE, 22, 1, 8-8 UE/XE,, 1, UE/XE - IE 2, 18, 1, UE/XE, 7, 1, UE/XE - IE, 22, 1, UE/XE, 4, 1, UE/XE - IE,, 1, 8-8 UN/XN - IE, 7, 1, 28) These values are valid for a density = 1 kg/dm³ and a kinematic viscosity of up to mm²/s. Amacan K

21 Amacan K 8-1, n = 8 rpm Characteristic curves to ISO 996 / 2 / 2B. The characteristic curves correspond to the effective motor speed. 8 Q [US.gpm] Q [IM.gpm] H [m] NPSH [m] Qmin ø8/9/76/6 ø98/71/47/11 ø84//27/14 ø67/1/27/14 Q [m³/h] Q [l/s] ø98/71/47/11 ø84//27/14 ø67/1/27/14 74 η [%] ø8/9/76/6 H [ft] NPSH [ft] 2 P [kw] P [hp] ø8/9/76/6 ø98/71/47/11 ø84//27/14 ø67/1/27/14 Q [m³/h] K4178/ Free passage = [1 mm] Rated power P 2 and mass moment of inertia J 29) Size Motor P 2 J [hp] [kw] [kgm 2 ] UE/XE, 1,, UE/XE 2, 18,, UE/XE, 22, 1, UE/XE - IE, 1, 1, UE/XE,, 1, UE/XE - IE 2, 18, 1, UE/XE, 7, 1, Size Motor P 2 J [hp] [kw] [kgm 2 ] UE/XE - IE, 22, 1, UE/XE - IE,, 1, UN/XN - IE, 7, 1, 29) These values are valid for a density = 1 kg/dm³ and a kinematic viscosity of up to mm²/s. Amacan K 21

22 Amacan K -4, n = 8 rpm Characteristic curves to ISO 996 / 2 / 2B. The characteristic curves correspond to the effective motor speed. 8 Q [US.gpm] 8 Q [IM.gpm] Qmin η [%] H [ft] H [m] ø4/4/417/7 ø/416//7 ø4/9//11 ø/76/48/12 ø87///14 ø/6//14 Q [m³/h] 1 2 Q [l/s] NPSH [m] ø/416//7 ø4/9//11 ø4/4/417/7 ø/76/48/12 ø87///14 ø/6//14 NPSH [ft] 8 P [kw] ø4/4/417/7 ø/416//7 ø4/9//11 ø/76/48/12 ø87///14 ø/6//14 P [hp] Q [m³/h] 1 2 K4179/ Free passage = 1 [ mm] Rated power P 2 and mass moment of inertia J ) Size Motor P 2 J [hp] [kw] [kgm 2 ] -4 8 UN/XN 67,, 1, UN/XN,, 2, UN/XN - IE, 6,, UN/XN - IE,,,47 ) These values are valid for a density = 1 kg/dm³ and a kinematic viscosity of up to mm²/s. 22 Amacan K

23 Amacan K -, n = 8 rpm Characteristic curves to ISO 996 / 2 / 2B. The characteristic curves correspond to the effective motor speed. 1 Q [US.gpm] Q [IM.gpm] Qmin H [m] ø8/a1 ø4/a1 ø48//42/ /A6 ø416/9/4/9 /A6 Q [m³/h] 1 2 Q [l/s] η [%] 82 8 H [ft] NPSH [m] ø4/a1 ø48//42/ /A6 ø8/a1 ø416/9/4/9 /A6 NPSH [ft] P [kw] ø4/a1 ø8/a1 ø48//42/ /A6 P [hp] ø416/9/4/9 /A6 Q [m³/h] 1 2 K418/ Free passage = 4 [1 mm] Rated power P 2 and mass moment of inertia J 1) Size Motor P 2 J [hp] [kw] [kgm 2 ] - 8 UN/XN,, 4,6-9 8 UN/XN 121, 9,, UN/XN 148, 1,,7-1 8 UN/XN - IE,,,7-8 UN/XN 174,,, UN/XN - IE 1, 9,, UN/XN - IE 1, 1, 11,69 1) These values are valid for a density = 1 kg/dm³ and a kinematic viscosity of up to mm²/s. Amacan K 2

24 Amacan K -, n = 8 rpm Characteristic curves to ISO 996 / 2 / 2B. The characteristic curves correspond to the effective motor speed. 1 2 Q [US.gpm] 1 Q [IM.gpm] Qmin H [ft] 8 8 η [%] H [m] ø//9 /A ø82//6 /A ø/12/49/14 /A6 ø/49/49/18 /A6 ø/4/49/2 /A6 Q [m³/h] Q [l/s] 1 NPSH [m] ø//9 /A ø/12/49/14 /A6 ø/49/49/18 /A6 ø82//6 /A ø/4/49/2 /A6 NPSH [ft] 2 P [kw] P [hp] 1 ø82//6 /A ø//9 /A ø/12/49/14 /A6 ø/49/49/18 /A6 ø/4/49/2 /A6 Q [m³/h] K4219/1 Free passage = 1 / 4 [1 mm] Rated power P 2 and mass moment of inertia J 2) Size Motor P 2 J [hp] [kw] [kgm 2 ] - 8 UN/XN 174,, 7, UN/XN, 1, 12, UN/XN 2, 18, 1, UN/XN 29, 2, 1,6-2 8 UN/XN, 2, 18, UN/XN - IE 2, 18, 18,49-8 UN/XN - IE 28, 2, 21, - 8 UN/XN - IE, 2, 24, 2) These values are valid for a density = 1 kg/dm³ and a kinematic viscosity of up to mm²/s. 24 Amacan K

25 n = rpm Amacan K -, n = rpm Characteristic curves to ISO 996 / 2 / 2B. The characteristic curves correspond to the effective motor speed. 8 Q [US.gpm] 8 Q [IM.gpm] 1 H [m] Qmin Q [m³/h] 1 2 Q [l/s] η [%] 8 ø8/a1 ø4/a1 ø416/9/4/9 /A6 ø48//42/ /A6 H [ft] NPSH [m] 6 4 ø4/a1 ø48//42/ /A6 ø8/a1 ø416/9/4/9 /A6 NPSH [ft] 8 P [kw] ø8/a1 ø4/a1 P [hp] ø48//42/ /A6 ø416/9/4/9 /A6 Q [m³/h] 1 2 K42272/1 Free passage = 4 [1 mm] Rated power P 2 and mass moment of inertia J ) Size Motor P 2 J [hp] [kw] [kgm 2 ] - UN/XN, 7, 4,87 - UN/XN 8,,, - UN/XN,,,2 ) These values are valid for a density = 1 kg/dm³ and a kinematic viscosity of up to mm²/s. Amacan K 2

26 Amacan K -, n = rpm Characteristic curves to ISO 996 / 2 / 2B. The characteristic curves correspond to the effective motor speed. 1 Q [US.gpm] 1 Q [IM.gpm] Qmin 1 H [m] NPSH [m] 8 Q [m³/h] Q [l/s] 8 8 η [%] ø//9 /A ø82//6 /A ø/12/49/14 /A6 ø/49/49/18 /A6 ø/4/49/2 /A6 ø//9 /A ø/12/49/14 /A6 ø/49/49/18 /A6 ø82//6 /A ø/4/49/2 /A6 H [ft] NPSH [ft] P [hp] 8 P [kw] ø82//6 /A ø//9 /A ø/12/49/14 /A6 ø/49/49/18 /A6 ø/4/49/2 /A6 Q [m³/h] KD = 1 mm K42194/ Free passage = 1 / 4 [1 mm] Rated power P 2 and mass moment of inertia J 4) Size Motor P 2 J [hp] [kw] [kgm 2 ] - UN/XN 8,, 7,1 - UN/XN,, 7,42-9 UN/XN 121, 9, 7,71-1 UN/XN 148, 1, 1,18-1 UN/XN, 1, 14,88 4) These values are valid for a density = 1 kg/dm³ and a kinematic viscosity of up to mm²/s. 26 Amacan K

27 Dimensions Motor version UE, XE [inch] A DB A h 2 h 4 h 1 c X h X d 2 d 1 4 Fig. 1: Pump set dimensions Pump set dimensions [inch] Size Motor c d 1 d 2 DB h 1 h 2 h h 4 [lbs] ) E 1 / 4 26 / / / / 2 1 / E 1 / 4 26 / / / / 2 1 / E 1 / 4 26 / / / / 2 1 / E 1 / 4 26 / / / / 2 1 / E 1 / 4 26 / / / / 2 1 / E 1 / 4 26 / / / / 2 1 / E 1 / 4 26 / / / / 2 1 / E 1 / 4 26 / / / / 2 1 / E 1 / 4 26 / / / / 2 1 / E 1 / 4 26 / / / / 2 1 / E 1 / 4 26 / / / / 2 1 / E 1 / 4 26 / / / / 2 1 / E 1 / 4 26 / / / / 2 1 / E 1 / 4 26 / / / / 2 1 / E 1 / 4 26 / / / / 2 1 / E 1 / 4 26 / / / / 2 1 / ) Pump set with m power cable (4 V) Amacan K 27

28 Size Motor c d 1 d 2 DB h 1 h 2 h h 4 [lbs] ) E / / / 2 41 / E / / / 2 41 / E / / / 2 41 / E / / / E / / / E 1 / / E 1 / / E / 2 9 / / E / / E / / E 1 / / E 1 / / E 1 / / E 1 / / E / 2 9 / / E / / E / / / 2 41 / E / / / 2 41 / E / / / E / / / E / / / 2 41 / E 1 / / E 1 / / E / E / 8 49 / E / 8 49 / E / E / 8 49 / E / 8 49 / E 1 / / E 1 / / E 1 / / E / E E / 8 49 / D D i h 18 4 h 19 h d 7 d Fig. 2: Seat ring dimensions Seat ring dimensions [inch] Size Motor D 6) D i d 7 d h 18 h 19 h E / / E / / E / / E / / E / / 8 6) D for recommended wall thickness of the discharge tube (see dimension s1 in the general arrangement drawings or in General Arrangement Drawings booklet ) 28 Amacan K

29 Size Motor D 6) D i d 7 d h 18 h 19 h - 6.E / / E / / E / / E / / E / / E / / E / / E / / E / / E / / E / / E 2 1 / / / E 2 1 / / / E 2 1 / / / E 2 1 / / / E 2 1 / / / E 2 1 / / / E 2 1 / / / E 2 1 / / / E 2 1 / / / E 2 1 / / / E 2 1 / / / E 2 1 / / / E 2 1 / / / E 2 1 / / / E 2 1 / / / E 2 1 / / / E 2 1 / / / E 2 1 / / / E 2 1 / / / E 2 1 / / / E 2 1 / / / E 2 1 / / / E 2 1 / / / E 2 1 / / / E 2 1 / / / E 2 1 / / / E 2 1 / / / E 2 1 / / / E 2 1 / / / E 2 1 / / / E 2 1 / / / E 2 1 / / / E 2 1 / / / E 2 1 / / / E 2 1 / / / 8 Amacan K 29

30 Motor version UE, XE [mm] A DB A h 2 h 4 h 1 c X h X d 2 d 1 4 Fig. : Pump set dimensions Pump set dimensions [mm] Size Motor c d 1 d 2 DB h 1 h 2 h h 4 [kg] 7) E E E E E E E E E E E E E E E E E E E ) Pump set with m power cable (4 V) Amacan K

31 Size Motor c d 1 d 2 DB h 1 h 2 h h 4 [kg] 7) E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E D D i h 18 4 h 19 h d 7 d Fig. 4: Seat ring dimensions Seat ring dimensions [mm] Size Motor D 8) D i d 7 d h 18 h 19 h E E E E E E E E E ) D for recommended wall thickness of the discharge tube (see dimension s1 in the general arrangement drawings or in General Arrangement Drawings booklet ) Amacan K 1

32 Size Motor D 8) D i d 7 d h 18 h 19 h E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E Amacan K

33 Motor version UN, XN [inch] A DB A h h 2 h 4 h 1 X X 4 d 2 d 1 Fig. : Pump set dimensions Pump set dimensions [inch] Size Motor d 1 d 2 DB h 1 h 2 h h 4 [lbs] 9) N / N / N / N / N / N / / / N / / N / / / N / / / N / / N / / N / / ) Pump set with m power cable (4 V) Amacan K

34 Size Motor d 1 d 2 DB h 1 h 2 h h 4 [lbs] 9) - 8.N / / N N N / / N / / N / / N 44 7 / N 44 7 / / / / N 44 7 / / / / N 44 7 / / / / N 44 7 / / / N 44 7 / / / N 44 7 / / / N 44 7 / N 44 7 / N 44 7 / N 44 7 / / / / N 44 7 / / / / D D i 4 h 18 h 19 h d 7 d Fig. 6: Seat ring dimensions Seat ring dimensions [inch] Size Motor D ) D i d 7 d h 18 h 19 h N 2 1 / / / N 2 1 / / / N 2 1 / / / N 2 1 / / / N 2 1 / / / N / N / N / N / 8-8.N / N / N / 8-8.N / N / N / 8 -.N / 8 -.N / 8 -.N / 8-8.N / N / N / N / 8 ) D for recommended wall thickness of the discharge tube (see dimension s1 in the general arrangement drawings or in General Arrangement Drawings booklet ) 4 Amacan K

35 Size Motor D ) D i d 7 d h 18 h 19 h N / 8-8.N / 8-8.N / 8 -.N / 8 -.N / 8-9.N / 8-1.N / 8-1.N / 8 Motor version UN, XN [mm] A DB A h 4 h 2 h 1 X X 4 h d 2 d 1 Fig. 7: Pump set dimensions 41) Pump set with m power cable (4 V) Amacan K

36 Pump set dimensions [mm] Size Motor d 1 d 2 DB h 1 h 2 h h 4 [kg] 41) N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N D D i 4 h 18 h 19 h d 7 d Fig. 8: Seat ring dimensions Seat ring dimensions [mm] Size Motor D 42) D i d 7 d h 18 h 19 h N N N N N N N N N ) D for recommended wall thickness of the discharge tube (see dimension s1 in the general arrangement drawings or in General Arrangement Drawings booklet ) 6 Amacan K

37 Size Motor D 42) D i d 7 d h 18 h 19 h - 8.N N N N N N N N N N N N N N N N N N N N N Amacan K 7

38 Types of installation a) b) c) Fig. 9: Overview of installation types a) BU installation (overflow design) b) CU installation (design with underfloor discharge) c) DU installation (design with above-floor discharge nozzle) Scope of supply Depending on the model, the following items are included in the scope of supply: Pump set complete with power cables O-ring Back-up name plate Optional accessories: Support rope Accessories for installing the cable guide: Spacer Turnbuckle Support Shackle Cable clamps Cable support sleeves Discharge tube 8 Amacan K

39 Accessories Pump set with support rope and turnbuckle in the discharge tube a) b) * A A Fig. : a) Pump set with support rope and turnbuckle in the discharge tube b) Pump set with support rope and turnbuckle in the discharge tube, with support spacer for large installation depths * Optionally available. The number depends on the lifting height of the lifting equipment and on the building structure. List of components Part No. Description Material Shackle Galvanized steel (optional: stainless steel) Shackle Stainless steel 9-24 Guide cable Stainless steel 9-47 Lifting ring (intermediate lifting ring) Stainless steel 9-7 Support GFRP 9-8 Turnbuckle Stainless steel 7 Spacer EPDM Amacan K 9

40 Cross-section of cable support Fig. 11: Cross-section of cable support List of components Part No. Description Part No. Description 1 Cable clamp (approximately every 4 Support rope 9-24 mm) 2 Control cable Spacer Power cable 6 Clamp cover Discharge tube cover with cable gland Design: with welding sleeve A - A 4 A A Fig. 12: Design variant with welding sleeve List of components Part No. Description Part No. Description 1 Discharge tube cover 4) 4 Threaded bush with cable entry to DIN with strain relief and protection against kinking and twisting 2 Cover Eyeplate for fastening the cable support (support rope) Welding sleeve 6 Gasket, e.g. fabric-reinforced rubber 4) Discharge tube cover also available in split design Amacan K

41 Design variant with transit frame (up to 1 bar) A - A X A X A 2 Fig. 1: Design variant with transit frame (up to 1 bar) List of components Part No. Description 1 Discharge tube cover 44) 2 Transit frame (cable gland) Packing blocks and insert blocks 4 Cover segment with cable gland Sealing of split cover with closed cell profile gasket 6 Gap cover 7 Support brackets for cover segment with cable glands 8 Gasket (e.g. rubber with fabric reinforcement) 44) Discharge tube cover also available in single-piece design Amacan K 41

42 General assembly drawings with list of components Motor version UE, XE Fig. 14: General assembly drawing, motor version UE, XE List of components Part No. Description Part No. Description 1 Pump casing 2 Casing wear ring 16 Discharge cover 71 Bail Impeller 811 Motor housing Bearing housing 818 Rotor 412 O-ring 84 Cable gland 4 Mechanical seal 42 Amacan K

43 Motor version UN, XN Fig. 1: General assembly drawing, motor version UN, XN List of components Part No. Description Part No. Description 1 Pump casing 2 Casing wear ring 16 Discharge cover 71 Bail Impeller 811 Motor housing Bearing bracket 812 Motor housing cover Bearing housing 818 Rotor 412 O-ring 84 Cable gland 4 Mechanical seal Amacan K 4

44 KSB Aktiengesellschaft Turmstraße Halle (Germany) Tel /4-EN-US 12/12/17

Submersible Pump in Discharge Tube. Amacan P. 60 Hz. Type Series Booklet

Submersible Pump in Discharge Tube. Amacan P. 60 Hz. Type Series Booklet Amacan P Hz Type Series Booklet Legal information/copyright Type Series Booklet Amacan P All rights reserved. The contents provided herein must neither be distributed, copied, reproduced, edited or processed

More information

Submersible Pump in Discharge Tube. Amacan P. 50 Hz. Type Series Booklet

Submersible Pump in Discharge Tube. Amacan P. 50 Hz. Type Series Booklet Amacan P 50 Hz Type Series Booklet Legal information/copyright Type Series Booklet Amacan P All rights reserved. The contents provided herein must neither be distributed, copied, reproduced, edited or

More information

Calio-Therm NC Type Series Booklet

Calio-Therm NC Type Series Booklet High-efficiency Drinking Water Pump Type Series Booklet Legal information/copyright Type Series Booklet All rights reserved. The contents provided herein must neither be distributed, copied, reproduced,

More information

Sewatec / Sewabloc Type Series Booklet

Sewatec / Sewabloc Type Series Booklet Dryinstalled Volute Casing Pump / 60 Hz DIN / IC motors Type Series Booklet Legal information/copyright Type Series Booklet All rights reserved. The contents provided herein must neither be distributed,

More information

Standardized Chemical Pumps. Fields of Application. Designation. Design. Operating Data. Type Series Booklet /7-10 G2 CPK-H

Standardized Chemical Pumps. Fields of Application. Designation. Design. Operating Data. Type Series Booklet /7-10 G2 CPK-H Type Series Booklet.5/7-0 G CPK-H Standardized Chemical Pumps to EN 5/ISO 5/ISO 599, heatable Automation products available: Hya-Drive Hyamaster hyatronic Fields of Application CPK-H pumps are used for

More information

High-efficiency Circulator Pump. Rio-Eco N / Rio-Eco Z N. Type Series Booklet

High-efficiency Circulator Pump. Rio-Eco N / Rio-Eco Z N. Type Series Booklet High-efficiency Circulator Pump Rio-Eco N / Rio-Eco Z N Type Series Booklet Legal information/copyright Type Series Booklet Rio-Eco N / Rio-Eco Z N KSB Aktiengesellschaft All rights reserved. The contents

More information

barmesapumps.com SELF-PRIMING CENTRIFUGAL TRASH PUMP SPECIFICATIONS Series: SH8-U Suction: 8" Discharge: 8" Spherical solids handling: 3"

barmesapumps.com SELF-PRIMING CENTRIFUGAL TRASH PUMP SPECIFICATIONS Series: SH8-U Suction: 8 Discharge: 8 Spherical solids handling: 3 SELF-PRIMING CENTRIFUGAL TRASH PUMP Series: SH-U Suction: " Discharge: " Spherical solids handling: 3" SIZE BEARING - PUMP END " x " NPT, lbs., female flange. Open single ball, radial load. LIQUID TEMPERATURE

More information

Contents. Identification LHC. Horizontal split case pumps. Type key. Identification Type key

Contents. Identification LHC. Horizontal split case pumps. Type key. Identification Type key Contents dentification Type key Product data ntroduction Applications Features and benefits Performance range pole pole pole Construction Sectional drawing Construction features Test pressure Operating

More information

Standardized Chemical Pumps to EN /ISO 2858/ISO 5199 sealless, with magnetic drive. Fields of Application. Designation. Design.

Standardized Chemical Pumps to EN /ISO 2858/ISO 5199 sealless, with magnetic drive. Fields of Application. Designation. Design. Type series booklet.5/- G2 Magnochem Standardized Chemical Pumps to EN 5/ISO 25/ISO 99 sealless, with magnetic drive Automation products available: PumpExpert Hyamaster hyatronic Fields of Application

More information

CMA - B - C - D - CMR

CMA - B - C - D - CMR Cast iron self-priming electric pumps. APPLICATIONS Pressure boosting domestic plants Small-scale irrigation Moving non-aggressive liquids for civil and industrial use Washing plants Washing vehicles CMA-B-C-D

More information

EVOTRON WET ROTOR ELECTRONIC CIRCULATORS TECHNICAL DATA APPLICATIONS ADVANTAGES

EVOTRON WET ROTOR ELECTRONIC CIRCULATORS TECHNICAL DATA APPLICATIONS ADVANTAGES TECNICAL DATA EVOTRON Operating range: from, -, m3/h with head of up to metres. Pumped liquid temperature range: from - C to + C. Working pressure: bar ( kpa). Protection class: IP X. Insulation class:

More information

Serie B2.1. Flanged ductile iron ball valve. made in. Application fields. Shut-off valves E U R O P E. 18

Serie B2.1. Flanged ductile iron ball valve. made in. Application fields. Shut-off valves E U R O P E. 18 erie B. Flanged ductile iron ball valve BRanDOni made in E U R O P E Application fields WATER CONdITIONING GA EATING INdUTRY FIRE FIGTING www.brandoni.it erie B. eries B. valves are shut-off ball valves

More information

The FLUX F 430 with mechanical seal

The FLUX F 430 with mechanical seal The FLUX F 0 with mechanical seal Flexible coupling between motor and pump The pump must be used with many varying liquids, consequently the smallest residual left within the pump is unacceptable. You

More information

Tangential Fans Series TW Impeller diameter 150 mm and 200 mm

Tangential Fans Series TW Impeller diameter 150 mm and 200 mm Tangential Fans Series TW Impeller diameter mm and 0 mm 105 Corporate Drive, Suite E Spartanburg, SC 293 PO Box 2889, Spartanburg, SC 294 USA Tel: 864-599-63 Fax: 864-599-6344 e-mail: info@ltg-inc.net

More information

LES. Single-stage end-suction pumps Identification Type key

LES. Single-stage end-suction pumps Identification Type key Contents Singlestage endsuction pumps Identification Type key Product data Introduction Applications Features and benefits Performance range pole pole 6 pole Construction Sectional drawing Construction

More information

Prima range. Alifter range. magnetical driven pumps in thermoplastic materials TMP TMA. centrifugal. self-priming

Prima range. Alifter range. magnetical driven pumps in thermoplastic materials TMP TMA. centrifugal. self-priming Prima range TMP centrifugal Alifter range magnetical driven pumps in thermoplastic materials TMA self-priming Prima - Alifter In this catalog Argal proposes the range of PRIMA pumps, magnetical driven,

More information

SINGLE IMPELLER CENTRIFUGAL ELECTRIC PUMPS in cast iron

SINGLE IMPELLER CENTRIFUGAL ELECTRIC PUMPS in cast iron Cast iron self-priming electric pumps. APPLICATIONS Pressure boosting domestic plants Small-scale irrigation Moving non-aggressive liquids for civil and industrial use Washing plants Washing vehicles CMA-B-C-D

More information

DOMESTIC HOT WATER PUMPS WITH FIXED-SPEED MOTOR, 3x400V AP-, AKP- and AEP- series, threaded G1/2 G1 ¼ LOREM IPSUM JE ZULT MAAR 60 HZ.

DOMESTIC HOT WATER PUMPS WITH FIXED-SPEED MOTOR, 3x400V AP-, AKP- and AEP- series, threaded G1/2 G1 ¼ LOREM IPSUM JE ZULT MAAR 60 HZ. LOREM IPSUM JE ZULT MAAR HZ m Head m/s m/s m/s m/s m/s Ø m Ø Ø Ø Ø l/s Flow kw Shaft power P Ø m/h Ø 9 Ø Ø kw 9 Total input power P Ø DOMESTIC HOT WATER PUMPS WITH FIXED-SPEED MOTOR, xv AP-, AKP- and AEP-

More information

Sewatec/Sewabloc Volute casing pump for dry-well installation 2-20 Discharge 60 Hz Applications Shaft Seal Operating data Materials

Sewatec/Sewabloc Volute casing pump for dry-well installation 2-20 Discharge 60 Hz Applications Shaft Seal Operating data Materials ype series booklet 80.6/--1 Sewatec/Sewabloc Volute casing pump for dry-well installation - Discharge 60 Hz Applications or the pumping of untreated waste water and sewage municipal and industrial. Operating

More information

IBV Series C Carbon Steel Inverted Bucket Vertical Steam Trap

IBV Series C Carbon Steel Inverted Bucket Vertical Steam Trap Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

IBV Series Z Alloy Steel Inverted Bucket Vertical Steam Trap

IBV Series Z Alloy Steel Inverted Bucket Vertical Steam Trap Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

E 094 E 103 E 143. Tank top mounting Connection up to G1 Nominal flow rate up to 135 l/min e

E 094 E 103 E 143. Tank top mounting Connection up to G1 Nominal flow rate up to 135 l/min e R e t u r n F i l t e rs E 094 E 103 E 143 Tank top mounting Connection up to G1 Nominal flow rate up to 135 l/min 20.30-5e D e s c r i p t i o n Application In the return line circuits of hydraulic systems.

More information

Single Phase Motors Technical Datasheets

Single Phase Motors Technical Datasheets Single Phase Motors Technical Datasheets EN A dynamic, strong and ambitious Group: Orange1 Holding is an international renown Group, one of the most important European manufacturers of single-phase and

More information

ISEmax CAM40/CAS40. Technical Information

ISEmax CAM40/CAS40. Technical Information Technical Information Online measurement of nutrient parameters Ion-selective electrode system for the continuous measurement of ammonium and nitrate Application The ion-selective electrode system works

More information

PiB Series. PiB (Pump-in-a-Box) 4380 & 4392 Series

PiB Series. PiB (Pump-in-a-Box) 4380 & 4392 Series PiB Series PiB (Pump-in-a-Box) & 9 Series FILE NO: - DATE: July SUPERSEDES: - DATE: January 09 PiB Series Guaranteed In Stock At The Right Price! The PiB series builds on the high quality and unsurpassed

More information

Made in Italy HOSE REELS CATALOGUE TECHNOLOGY FOR FLUIDYNAMICS. No. E14/A1

Made in Italy HOSE REELS CATALOGUE TECHNOLOGY FOR FLUIDYNAMICS. No. E14/A1 Made in Italy HOSE REELS CATALOGUE TECHNOLOGY FOR FLUIDYNAMICS No. E14/A1 The complete range of our products is presented in the specific catalogues: HOSE REELS CATALOGUE No. E14/A2 HOSE REELS CATALOGUE

More information

ED 701 General Industry Pressure Transmitter

ED 701 General Industry Pressure Transmitter ED 701 General Industry Pressure Transmitter Standard industrial process connections Complete range of electrical connections 4... 20 ma and Voltage outputs Accuracy: 0.1%, 0.2% and 0.4% FS Quick response

More information

IL series. Centrifugal marine IN-LINE pumps

IL series. Centrifugal marine IN-LINE pumps IL series Centrifugal marine IN-LINE pumps DESCRIPTION Vertically built centrifugal IN-LINE pumps are made with standardized DIN-22 parts, with in-line suction and discharge flanges. This arrangement requires

More information

DEBEM IM VERTICAL CENTRIFUGAL PUMPS.

DEBEM IM VERTICAL CENTRIFUGAL PUMPS. IM VERTICA CENTRIFUGA PUMPS The IM series of resin-encased vertical centrifugal pumps features high-performance pumps for fixed installations with pump immersed directly in the tank and operated by a directdrive

More information

60 Hz. e-nsc Series HORIZONTAL CENTRIFUGAL ELECTRIC PUMPS EQUIPPED WITH IE3 MOTORS

60 Hz. e-nsc Series HORIZONTAL CENTRIFUGAL ELECTRIC PUMPS EQUIPPED WITH IE3 MOTORS 6 Hz e-nsc Series HORIZONTAL CENTRIFUGAL ELECTRIC PUMPS EQUIPPED WITH IE3 MOTORS Cod. 19112831 Rev. B Ed.7/217 Xylect TM Xylect TM is a pump solution software with an extensive online database of product

More information

2.3 T214 PTFE-LINED BUTTERFLY VALVE T 214 TECHNICAL DATA

2.3 T214 PTFE-LINED BUTTERFLY VALVE T 214 TECHNICAL DATA -INED BUTTERFY VAVE T ug type valve for corrosive and aggressive media. The patented shaft seal design ensures reliability even with high-corrosive applications. TECNICA DATA Nominal diameter: 0 Face-to-face:

More information

1.2 Z 014-A LUG TYPE BUTTERFLY VALVE Z 014-A TECHNICAL DATA:

1.2 Z 014-A LUG TYPE BUTTERFLY VALVE Z 014-A TECHNICAL DATA: TECNICA DATA: ug type butterfly valve with threaded holes. This type enables the one-sided lugging of pipes. Nominal diameter: Face-to-face: EN Series (DIN T ) ISO Series API 0 Table BS Series NF E -0.

More information

Turbine Meter TRZ 03 PRODUCT INFORMATION. Reliable Measurement of Gas

Turbine Meter TRZ 03 PRODUCT INFORMATION. Reliable Measurement of Gas Turbine Meter TRZ 0 PRODUCT INFORMATION Reliable Measurement of Gas TURBINE METER TRZ 0 Method of operation, Construction Method of operation The TRZ 0 turbine meter is a flow meter suitable for gas measurement

More information

14:1400 (0206) KRAL Volumeter - OMG

14:1400 (0206) KRAL Volumeter - OMG 14:1400 (0206) KRAL Volumeter - OMG OMG - Universal OMG The flowmeter for a wide range of applications Operating Conditions and Materials Flow Range: 0.1 to 7,500 l/min Max. Pressure: 250 bar Temperature

More information

VOLUMEC. Valve Position Indicator 5

VOLUMEC. Valve Position Indicator 5 VOLUMEC Valve Position Indicator 5 2 KRACHT CORP. 8600 S Wilkinson Way Unit A Perrysburg, OH 43551 USA P +1 419 874 1000 F +1 419 874 1006 flowmeters@krachtcorp.com www.krachtcorp.com VOLUMEC Valve Position

More information

TPH. 60Hz. Standard mode TPH 4T 2K. Code TPH 4T 2K S F A H

TPH. 60Hz. Standard mode TPH 4T 2K. Code TPH 4T 2K S F A H C US NSF/ANSI TPH Applications: The TPH Series are modernly designed with quiet and high efficient operation pumps, suitable for dependable water transfer, circulating or booster service. -Industrial circulation

More information

Pressure Measurement. Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level 2/27

Pressure Measurement. Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level 2/27 Overview Siemens AG 011 Function s are for measuring the liquid levels in wells, tanks, channels and dams. Diaphragm p Sensor U const. U + (brown) I EM I -1 (blue) 0, U B s are submersible sensors for

More information

Its modular concept allows to build up a ball valve for any degree of automation and any kind of application

Its modular concept allows to build up a ball valve for any degree of automation and any kind of application Type 2657...59 DN 10 up to 80 mm; Plastic; 2/2 way dvantages/benefits ntegrated pilot valves, position feed-back and limit switches available Customized system solutions with Burkert valves & sensors With

More information

2.3 T 214-A TECHNICAL DATA

2.3 T 214-A TECHNICAL DATA -INED BUTTERFY VAVE T -A ug type valve for corrosive and aggressive media. The patented shaft seal design ensures reliability even with high-corrosive applications. TECNICA DATA Nominal diameter: 0 Face-to-face:

More information

2.1 T211 PTFE-LINED BUTTERFLY VALVE T 211 TECHNICAL DATA

2.1 T211 PTFE-LINED BUTTERFLY VALVE T 211 TECHNICAL DATA -INED BUTTERFY VAVE T Fully -lined wafer type valve for corrosive and aggressive media. The patented shaft seal design ensures reliability even with highcorrosive applications. TECNICA DATA Nominal diameter:

More information

1.2 Z 014-A LUG TYPE BUTTERFLY VALVE Z 014-A TECHNICAL DATA

1.2 Z 014-A LUG TYPE BUTTERFLY VALVE Z 014-A TECHNICAL DATA ug type butterfly valve with threaded holes. This type enables the one-sided lugging of pipes. TECNICA DATA Nominal diameter: 00 ( only PN0/) Face-to-face: EN Series (DIN T ) ISO Series API 0 Table BS

More information

DBS315 1-phase SIDE CHANNEL BLOWERS

DBS315 1-phase SIDE CHANNEL BLOWERS DBS15/ 1-phase DESCRIPTION Dutair blowers for pressure and vacuum are compact machines consisting of an electric motor with a built-on pump housing. The rotational speed of the impeller creates a high

More information

Chapter Four Hydraulic Machines

Chapter Four Hydraulic Machines Contents 1- Introduction. 2- Pumps. Chapter Four Hydraulic Machines (لفرع الميكانيك العام فقط ( Turbines. -3 4- Cavitation in hydraulic machines. 5- Examples. 6- Problems; sheet No. 4 (Pumps) 7- Problems;

More information

ISO 9906 INTERNATIONAL STANDARD. Rotodynamic pumps Hydraulic performance acceptance tests Grades 1 and 2

ISO 9906 INTERNATIONAL STANDARD. Rotodynamic pumps Hydraulic performance acceptance tests Grades 1 and 2 INTERNATIONAL STANDARD ISO 9906 First edition 1999-1-15 Rotodynamic pumps Hydraulic performance acceptance tests Grades 1 and Pompes rotodynamiques Essais de fonctionnement hydraulique pour la réception

More information

Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level

Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level Overview Function s are for measuring the liquid levels in wells, tanks, channels and dams. Sensor Diaphragm p U const. U +2 (brown) I EM I - (blue) 0, U B s are submersible sensors for hydrostatic level

More information

2.1 T 211-A TECHNICAL DATA

2.1 T 211-A TECHNICAL DATA PTFE-INED BUTTERFY VAVE T -A Fully PTFE-lined wafer type valve for corrosive and aggressive media. The patented shaft seal design ensures reliability even with high-corrosive applications. TECNICA DATA

More information

WAFER PATTERN BUTTERFLY TYP Z 011-A

WAFER PATTERN BUTTERFLY TYP Z 011-A TECNICA DATA A universally applicable wafer type valve acc. to EN 3. The large variety of basic materials allows applications in different industries. Nominal diameter: 0 ( only PN0/) Face-to-face: EN

More information

BNA Series. PLENUM FAN with Backward Wheels

BNA Series. PLENUM FAN with Backward Wheels BNA Series PLENUM FAN with Backward Wheels BNA Series BNA Series Plenum Fans Backward wheels Kruger Plenum Fans are designed for air handling applications where the fan operates unhoused within a plenum.

More information

50 Hz n= 2900 rpm. Standardised EN 733 centrifugal pumps INSTALLATION AND USE. PERFORMANCE RANGE Flow rate up to 6000 l/min (360 m³/h) Head up to 98 m

50 Hz n= 2900 rpm. Standardised EN 733 centrifugal pumps INSTALLATION AND USE. PERFORMANCE RANGE Flow rate up to 6000 l/min (360 m³/h) Head up to 98 m F Standardised EN 733 centrifugal pumps Hz n= 9 rpm Clean water Industrial use PERFORMNCE RNGE Flow rate up to (3 ) Head up to 9 m PPLICTION LIMITS Manometric suction lift up to 7 m Liquid temperature

More information

NKVE VERTICAL AXIS MULTISTAGE CENTRIFUGAL PUMPS WITH MCE/P INVERTER

NKVE VERTICAL AXIS MULTISTAGE CENTRIFUGAL PUMPS WITH MCE/P INVERTER NKVE 1-1--3--6-9 VERTICAL AIS MULTISTAGE CENTRIFUGAL PUMPS WIT MCE/P INVERTER TECNICAL DATA Operating range: fro to 118 3 /h with head up to 31 etres. Puped liquid: clean, free of solids and abrasives,

More information

Air Cooler Industry AC-LN 1-7 / ACA-LN 2-7 / ACAF-LN 2-7

Air Cooler Industry AC-LN 1-7 / ACA-LN 2-7 / ACAF-LN 2-7 ir ooler Industry -LN -7 / -LN -7 / F-LN -7 Symbol General The -LN -7 air cooler series can be used in all areas where either oil or water-glycol is to be cooled with air. The coolers with an axial fan

More information

O-Ring Design Guide REGISTERED QMS. ISD

O-Ring Design Guide REGISTERED QMS. ISD O-Ring Design Guide ISO 9001 REGISTERED QMS ISD Table of Contents O-Ring Design Guide Hi-Tech Seals Inc. Compound Specifications 3 Machining Specifications 4 O-Ring -Section 4 O-Ring Gland Types 4 ID Stretch/OD

More information

Single Phase Motors Technical Datasheets

Single Phase Motors Technical Datasheets Single Phase Motors Technical Datasheets EN A dynamic, strong and ambitious Group: Orange1 Holding is an international renown Group, one of the most important European manufacturers of single-phase and

More information

Ex floating switches and Ex immersion probes

Ex floating switches and Ex immersion probes Ex floating switches and Ex immersion probes Controlling devices with ball-operated microswitch, for signalling or regulation of liquid levels Jola Spezialschalter GmbH & Co. KG Klostergartenstr. 11 67466

More information

ALUMINIUM CENTRIFUGAL FANS. 4 x M6 x 16

ALUMINIUM CENTRIFUGAL FANS. 4 x M6 x 16 DESCRIPTION Dutair BCT-series aluminium centrifugal fans with open die-cast aluminium impellers and forward curved blades are suitable for material transport and high pressure applications. The asynchronous

More information

ALUMINIUM CENTRIFUGAL FANS M20 4 x M5 x 10 INLET. 4 x M5 x 12

ALUMINIUM CENTRIFUGAL FANS M20 4 x M5 x 10 INLET. 4 x M5 x 12 BCT61 DESCRIPTION Dutair BCT-series aluminium centrifugal fans with open die-cast aluminium impellers and forward curved blades are suitable for material transport and high pressure applications. The asynchronous

More information

ISEmax CAS40D. Technical Information

ISEmax CAS40D. Technical Information Technical Information ISEmax CAS40D Online measurement of nutrient parameters Ion-selective electrodes for the continuous measurement of ammonium, nitrate and other ions Application The ion-selective sensor

More information

1.7 Z 411 WAFER TYPE BUTTERFLY VALVE Z 411 TECHNICAL DATA

1.7 Z 411 WAFER TYPE BUTTERFLY VALVE Z 411 TECHNICAL DATA WAFER TYPE BUTTERFY VAVE Z TECNICA DATA Nominal diameter: Face-to-face: EN Series (DIN T 1) ISO Series API 09 Table 1 BS 1 Series NF E 9-.1 Flange accomotion: DIN 1 PN Top flange: prepared for EN ISO Marking:

More information

e-mp Series MPA, MPR, MPD, MPV Lenntech 50 Hz Tel Fax

e-mp Series MPA, MPR, MPD, MPV Lenntech 50 Hz Tel Fax Hz e-mp Series MPA, MPR, MPD, MPV HIGH PRESSURE MULTISTAGE PUMPS ACCORDING TO ISO 199 Lenntech info@lenntech.com Tel. +31-1-1-9 www.lenntech.com Fax. +31-1-1-9 Cod. 1911 Rev. A Ed.3/17 Xylect TM Xylect

More information

NM, NMD 60 Hz NM, NMD. Close Coupled Centrifugal Pumps with threaded ports

NM, NMD 60 Hz NM, NMD. Close Coupled Centrifugal Pumps with threaded ports , D z Close Coupled Centrifugal ups Construction Close-coupled, centrifugal pups; electric otor with extended sha directly connected to the pup. : single-ipeller D: with two back-to-back ipellers (with

More information

Pressure Transmitter ED 701

Pressure Transmitter ED 701 Pressure Transmitter ED 701 Hygienic and industrial process connections Zero setting function Accuracy < 0.1% FS Quick response time < 25 ms High long-term stability Excellent repeatability Active compensation

More information

DRUM MOTOR DM 0080 DRUM MOTOR DM Technical data. Design variants and accessories

DRUM MOTOR DM 0080 DRUM MOTOR DM Technical data. Design variants and accessories Practice-iented, scalable and thought out in detail: The new drum mot makes it easy to ild a completely indidual convey system and is dimensioned f the higher requirements f permissible belt tension from

More information

VDN2.. VEN2.. VUN2.. Radiator valves. Building Technologies HVAC Products ACVATIX TM. NF norm, for 2-pipe heating systems

VDN2.. VEN2.. VUN2.. Radiator valves. Building Technologies HVAC Products ACVATIX TM. NF norm, for 2-pipe heating systems 06 EN - Straight valves VDN.. Angle valves VEN.. Reverse angle valves VUN.. ACVATIX TM Radiator valves NF norm, for -pipe heating systems VDN.. VEN.. VUN.. Valve bodies made of brass, mat nickel-plated

More information

CV3000 Series. Characterized Insert Control Valves

CV3000 Series. Characterized Insert Control Valves CV3000 Series Characterized Insert Control Valves The CV3000 Series is a v-type control valve for precise control allowing high pressure drop capability with straight-through flow and bubble-tight shut

More information

Variable Displacement Plug-In Motor A6VE. Series 6, for open and closed circuits Axial tapered piston, bent axis design

Variable Displacement Plug-In Motor A6VE. Series 6, for open and closed circuits Axial tapered piston, bent axis design rueninghaus Hydromatik Series 6, for open and closed circuits xial tapered piston, bent axis design Size 28...20 Nom. pressure up to 400 bar Peak pressure up to 40 bar RE 9606/0.97 RE 9606/0.97 replaces

More information

50/60 Hz. ecocirc XL and XLplus. high efficiency WET ROTOR circulators. ErP 2009/125/EC

50/60 Hz. ecocirc XL and XLplus. high efficiency WET ROTOR circulators. ErP 2009/125/EC / Hz ecocirc XL and XLplus high efficiency WET ROTOR circulators FOR COMMERCIAL HEATING AND COOLING applications ErP 9/1/EC Cod. 1971 Rev. C Ed.11/1 Lowara, ecocirc, Xylect are trademarks of Xylem Inc.

More information

COMMON BLACK IRON & BLADE PARTS

COMMON BLACK IRON & BLADE PARTS LT RD HD SW PP 0 PP KIT, ALL BLADE LABEL 0 LABEL, BLADE CENTER 0 0 0 0 KIT, LABEL BLACK IRON COVER, HYDRAULICS 0 KIT, COTTER () / R PIN () PLOW PACK KIT, GREASE ZERK ( PACK) CONTROLS / MODULES CONTROL

More information

ALUMINIUM CENTRIFUGAL FANS. 4 x M6 x OUTLET x M6 x 20

ALUMINIUM CENTRIFUGAL FANS. 4 x M6 x OUTLET x M6 x 20 DESCRIPTION Dutair LK-series industrial ventilators consist of a robust body made from die-cast aluminium alloy. Impellers are made of extruded aluminium. The asynchronous electric motors are maintenance

More information

ALUMINIUM CENTRIFUGAL FANS x M6 x x M6 x 16

ALUMINIUM CENTRIFUGAL FANS x M6 x x M6 x 16 LK4 DESCRIPTION Dutair LK-series industrial ventilators consist of a robust body made from die-cast aluminium alloy. Impellers are made of extruded aluminium. The asynchronous electric motors are maintenance

More information

Cooling Water Flow Regulator

Cooling Water Flow Regulator Temperature controlled, indirectly and directly actuated diaphragm valves / seat valves Port size G 3/8 to G DN 0 to DN 0 ontinuous regulation High accuracy No auxiliary energy required Technical data

More information

High Pressure fi lters. FHB series. Maximum working pressure up to 32 MPa (320 bar) - Flow rate up to 485 l/min

High Pressure fi lters. FHB series. Maximum working pressure up to 32 MPa (320 bar) - Flow rate up to 485 l/min High Pressure fi lters FHB series Maximum working pressure up to MPa (0 bar) - Flow rate up to 8 l/min High Pressure fi lters Introduction FILTER SIZING INDEX CALCULATION CORRECTIVE FACTOR Page Introduction

More information

GRUNDFOS DATA BOOKLET MAGNA, UPE. Series 2000 circulator pumps

GRUNDFOS DATA BOOKLET MAGNA, UPE. Series 2000 circulator pumps GRUNDFOS DATA BOOKLET MAGNA, UPE Series circulator pumps Contents Product data MAGNA/UPE 3 Duty range 3 Characteristic features 3 Benefits 3 Applications 3 eating systems 3 Pumped liquids 3 Type key Performance

More information

Centrifugal Fans double inlet with direct drive backwardcurved true airfoil blades. Issue 1.4 September 2013

Centrifugal Fans double inlet with direct drive backwardcurved true airfoil blades. Issue 1.4 September 2013 Centrifugal Fans double inlet with direct drive backwardcurved true airfoil blades Issue 1.4 September 013 1 The overall picture will decide Complete systems by Nicotra ebhardt Depending on the model of

More information

Maximum pressure 420 bar Flow rate to 152 l/min. 560 bar. 140 l/min. Flow rate l/min FMM 050 1/2 1,50 3/4 1,00. Δp bar 0,50 0,00 FHA 051 1,50 1,00

Maximum pressure 420 bar Flow rate to 152 l/min. 560 bar. 140 l/min. Flow rate l/min FMM 050 1/2 1,50 3/4 1,00. Δp bar 0,50 0,00 FHA 051 1,50 1,00 FMM 00 Maximum pressure 0 bar Flow rate to l/min FHA 0 Maximum pressure 60 bar Flow rate to 0 l/min Technical data FMM 00 Filter housing (Materials) Head: Cast iron (chemical heat treatment) Housing: Steel

More information

Pressure Measurement Single-range transmitters for general applications

Pressure Measurement Single-range transmitters for general applications Siemens AG 07 Overview Function SITRANS LH00 Transmitter for hydrostatic level U const. p U I EM Sensor Connection for auxiliary power supply Vent pipe with humidity filter Protective conductor connection/

More information

Product Description. Further highlights. Outstanding features. 4 Bosch Rexroth Corporation Miniature Linear Modules R310A 2418 (2009.

Product Description. Further highlights. Outstanding features. 4 Bosch Rexroth Corporation Miniature Linear Modules R310A 2418 (2009. 4 Bosch Rexroth orporation Miniature Linear Modules R310A 2418 (2009.05) Product Description Outstanding features Rexroth Miniature Linear Modules are precise, ready-to-install linear motion systems that

More information

RIMA OFFICIAL CATALOGUE CATALOGUE TP

RIMA OFFICIAL CATALOGUE CATALOGUE TP RAIL BRAKES RIMA OFFICIAL CATALOGUE UE 1 / 1 4 FEBRUARY 2013 CATALOGUE TP UE 2 / 1 4 DescriPt Ption Utilization and functioning Rail brakes, suitable for medium forces from 20 to 300 kn (securing cranes

More information

GRUNDFOS DATA BOOKLET MAGNA, UPE. Series 2000 circulator pumps

GRUNDFOS DATA BOOKLET MAGNA, UPE. Series 2000 circulator pumps GRUNDFOS DATA BOOKLET MAGNA, UPE Series circulator pumps Contents Product data MAGNA and UPE 3 Duty range 3 Characteristic features 3 Benefits 3 Applications 3 eating systems 3 Pumped liquids Type key

More information

ABB SpA COMEM Operating Unit Strada Regionale 11, Signolo Montebello Vicentino (VI) - ITALY

ABB SpA COMEM Operating Unit Strada Regionale 11, Signolo Montebello Vicentino (VI) - ITALY ABB SpA COMEM Operating Unit Strada Regionale 11, Signolo 22 36054 Montebello Vicentino (VI) - ITALY www.abb.com/transformercomponents The information contained in this document is for general information

More information

Digital AC Motors MHD

Digital AC Motors MHD Digital AC Motors MHD090 8-1 8 MHD090 8.1 Technical Data Description Symbol Unit MHD090B-035 Type of cooling Natural Natural Surface Liquid Motor overtemperature 60 K 100 K 60 K/100 K 60 K/100 K Electric

More information

SPECIFICATION SS 51/9 400KV COUPLING CAPACITORS FOR POWER LINE CARRIER SYSTEM

SPECIFICATION SS 51/9 400KV COUPLING CAPACITORS FOR POWER LINE CARRIER SYSTEM INDEPENDENT POWER TRANSMISSION OPERATOR S.A. TNPRD/ SUBSTATION SPECIFICATION & EQUIPMENT SECTION January 2017 SPECIFICATION SS 51/9 400KV COUPLING CAPACITORS FOR POWER LINE CARRIER SYSTEM I. SCOPE This

More information

THREADED CLOSURES. For access to Filter Vessels, Strainers, Pig Launchers & Receivers. Tube Turns Products

THREADED CLOSURES. For access to Filter Vessels, Strainers, Pig Launchers & Receivers. Tube Turns Products THREADED CLOSURES For access to Filter Vessels, Strainers, Pig Launchers & Receivers Tube Turns Products HISTORY Tube Turns was founded in 927 in Louisville, Kentucky, USA. We were the f i r s t A m e

More information

GRUNDFOS DATA BOOKLET MAGNA, UPE. Series 2000 circulator pumps

GRUNDFOS DATA BOOKLET MAGNA, UPE. Series 2000 circulator pumps GRUNDFOS DATA BOOKLET Series circulator pumps Contents Product data MAGNA and UPE 3 Duty range 3 Characteristic features 3 Benefits 3 Applications 3 eating systems 3 Pumped liquids 3 Type key Performance

More information

Check-Q-meter. Table of contents. Features. Functions. RE 27551/ /10 Replaces: Type FD

Check-Q-meter. Table of contents. Features. Functions. RE 27551/ /10 Replaces: Type FD Check-Q-meter RE /0.0 /0 Replaces: 09.9 Type FD Nominal size... Series ax. Operating pressure 0 bar ax. Flow 0 l/min K9/ Table of contents Contents Page Features Functions Ordering details Symbols Functional

More information

Pressure transmitters for industrial applications MBS 32 and MBS 33

Pressure transmitters for industrial applications MBS 32 and MBS 33 Data sheet Pressure transmitters for industrial applications MBS 32 and MBS 33 The standard pressure transmitters MBS 32 and MBS 33 are designed for use in almost all industrial applications, and offer

More information

TOTAL HEAD, N.P.S.H. AND OTHER CALCULATION EXAMPLES Jacques Chaurette p. eng., June 2003

TOTAL HEAD, N.P.S.H. AND OTHER CALCULATION EXAMPLES Jacques Chaurette p. eng.,   June 2003 TOTAL HEAD, N.P.S.H. AND OTHER CALCULATION EXAMPLES Jacques Chaurette p. eng., www.lightmypump.com June 2003 Figure 1 Calculation example flow schematic. Situation Water at 150 F is to be pumped from a

More information

DRUM MOTOR DM 0080 DRUM MOTOR DM Technical data. Design variants and accessories

DRUM MOTOR DM 0080 DRUM MOTOR DM Technical data. Design variants and accessories Practice-iented, scalable and thought out in detail: The new drum mot makes it easy to ild a completely indidual convey system and is dimensioned f the higher requirements f permissible belt tension from

More information

Etachrom NC. Standardised Pumps. Bearings. Fields of Application. Shaft Seal

Etachrom NC. Standardised Pumps. Bearings. Fields of Application. Shaft Seal Type Series Booklet 1./11EN G2 Etachrom NC Standardised Pumps utomation products available: PumpDrive (MM) Hyamaster hyatronic Fields of pplication Water supply Fire-fighting systems Sprinkling Irrigation

More information

143 EEX gerotor pump unit. For use in oil circulation systems in gas- and dust-ex-atmospheres

143 EEX gerotor pump unit. For use in oil circulation systems in gas- and dust-ex-atmospheres 1 EEX gerotor pump unit For use in oil circulation systems in gas- and dust-ex-atmospheres Gerotor pump series 1 EEX The 1 EEX product series has been specifically designed for centralized lubrication

More information

v = m / s Thermal Flow Sensors TA with thin-film sensor element Probes Probe Guides Measuring Tubes

v = m / s Thermal Flow Sensors TA with thin-film sensor element Probes Probe Guides Measuring Tubes Thermal Flow Sensors TA with thin-film sensor element Probes Probe Guides Measuring Tubes Examples of Application Flow measurements also in hazardous locations X zone 0 or zone 1 in clean rooms in air

More information

Working pressure. 320 bar. Style T. Style D. Style S. Style B B B D.I. D.I. D.I. D.I.

Working pressure. 320 bar. Style T. Style D. Style S. Style B B B D.I. D.I. D.I. D.I. 8 FB SERIES FB Working pressure 0 bar Style S Style B Style T Style D B B B B D.I. D.I. D.I. D.I. A A A A 8 Technical data Filter body (Materials) ead: Cast iron (chemical heat treatment) ousing: Steel

More information

T20WN. Data Sheet. Torque transducers. Special features. Installation example with bellows couplings. B en

T20WN. Data Sheet. Torque transducers. Special features. Installation example with bellows couplings. B en T20WN Torque transducers Data Sheet Special features - Nominal (rated) torques 0.1 N m, 0.2 N m, 0. N m, 1 N m, 2 N m, N m, 10 N m, 20 N m, 0 N m, 100 N m, 200 N m - Accuracy class: 0.2 - Contactless transmission

More information

Flow rates to 485 l/min

Flow rates to 485 l/min FB Maximum pressure 0 bar Flow rates to 8 l/min Technical data Filter housing (Materials) ead: Cast iron (chemical heat treatment) ousing: Steel (chemical heat treatment) Bypass valve: Steel Check valve:

More information

Surface-mounting Thermostats ATH Type Series

Surface-mounting Thermostats ATH Type Series Page 1/9 urface-mounting Thermostats ATH eries k enclosure protection IP 54 k tested to IN EN 14597 (replacing IN 3440) Brief description Thermostats control and monitor thermal processes. Instruments

More information

LD-LP-LL-LC Rope Safety Switches with reset for emergency stop

LD-LP-LL-LC Rope Safety Switches with reset for emergency stop TECHNICA DATASHEET D-P--C Rope Safety Switches with reset for emergency stop Metal or polymer housing, from one or three conduit entries Protection degree IP6 In conformity with EN ISO 13850 contact blocks

More information

COURSE CODE : 3072 COURSE CATEGORY : B PERIODS/ WEEK : 5 PERIODS/ SEMESTER : 75 CREDIT : 5 TIME SCHEDULE

COURSE CODE : 3072 COURSE CATEGORY : B PERIODS/ WEEK : 5 PERIODS/ SEMESTER : 75 CREDIT : 5 TIME SCHEDULE COURSE TITLE : FLUID MECHANICS COURSE CODE : 307 COURSE CATEGORY : B PERIODS/ WEEK : 5 PERIODS/ SEMESTER : 75 CREDIT : 5 TIME SCHEDULE MODULE TOPIC PERIOD 1 Properties of Fluids 0 Fluid Friction and Flow

More information

Flow rates to 475 l/min

Flow rates to 475 l/min FMP Maximum pressure 0 bar Flow rates to 7 l/min Technical data PRSSUR FILTR Filter housing (Materials) ead: Cast iron (chemical heat treatment) ousing: Steel (chemical heat treatment) Bypass valve: Brass

More information

e-sh Series Lenntech 60 Hz Tel Fax

e-sh Series Lenntech 60 Hz Tel Fax Hz e-sh Series HORIZONTAL CENTRIFUGAL ELECTRIC PUMPS ACCORDING TO EN 733 MADE IN AISI 31 STAINLESS STEEL AND EQUIPPED WITH IE3 MOTORS Lenntech info@lenntech.com Tel. +31-1-1-9 www.lenntech.com Fax. +31-1-1-89

More information

Residual Chlorine Monitor

Residual Chlorine Monitor Data Sheet SS/AW00 Issue Residual Chlorine Monitor AW00 Total and Free Residual Chlorine Measurement add potassium iodide to reagent to convert free chlorine measurement to total chlorine Reagentless Operation

More information

SVH with HYDROVAR (HVL range)

SVH with HYDROVAR (HVL range) SVH with HYDROVAR (HVL range) SVH-HVL Rev. B Ed.9/1 (EN) SVH SERIES (e-sv WITH HYDROVAR) Background and context For all pumping needs in commercial or residential building and in industry applications,

More information