Focus XC + 6 Microwave capability = Infinity Explore Infinite Possibilities. with the Infinity Microwave Peptide Synthesizer
|
|
- Louisa Manning
- 5 years ago
- Views:
Transcription
1 Focus XC + 6 Microwave capability = Infinity 2400 Explore Infinite Possibilities with the Infinity 2400
2 In 1995, when Mr. Hans Tanner began testing microwave peptide synthesis with Dr. Hossain Saneii, currently CEO of AAPPTec, they discovered that microwave assisted synthesis could be beneficial in some difficult sequences, although there were limitations. The limitations they observed are the same limitations that others have reported with current commercial microwave peptide synthesizers today *. We were inspired to address these limitations by combining on demand microwave heating with the proven Focus XC. The result is the Infinity 2400, the latest technology in microwave peptide synthesis.** Infinity 2400 Advantages Over 880 unattended couplings Precisely measured reagent delivery Per coupling temperature control 6 peptides with variable scales microwaved simultaneously Mechanical mixing/n2 bubbling Large/small scale synthesis On-instrument cleavage Chill pre-activated amino acids mmol scale * Linkedin, Amino Acids & Peptides Community, Discussion: How much useful of Microwave peptidesynthesis in terms of industry side ( popular-0-b-ttl&goback=%2eamf_ _ %2egmp_ ) ** Patent pending
3 Microwave Heating or Ambient Temperature Our instrument offers precision temperature control utilizing the latest in microwave technology. Our unique system allows you to control your peptide's temperature on a coupling by coupling basis for up to 6 peptides at a time. Mixing / Reaction Vessels You can use mechanical agitation, nitrogen bubbling or a combination of both to provide thorough, efficient mixing during your synthesis. Our easily interchangable reaction vessels are made of glass for clear observation allowing you to visually observe the progress of your synthesis. Infinity 2400 reaction vessels are interchangable in sizes ranging from 5 ml to 300 ml.
4 Large Capacity Our offers unmatched capacity and on-demand thermo-flexibility. You can utilize up to 6 reaction vessels, each with a different synthesis scale. With the option of 5 ml up to 300 ml reaction vessels, you can scale your peptide production from laboratory research to large scale production. Easy to Use Infinity 2400 software Our software includes easy-to-use standard protocols for novices and allows experienced peptide chemists to develop custom methods to optimize peptide synthesis or make complex modifications such as cyclization and side chain modification. You can set temperature and coupling conditions for each amino acid. Additionally, you can pause synthesis to remove samples, check coupling, modify protocols, and restart your synthesis without reprogramming. Our software automatically calculates quantities of reagents and amino acids required for your synthesis preventing delays from running out of reagents and eliminating preparation of more amino acid or reagent than is needed. Amino Acid / Reagents Our instrument comes standard with 24 large capacity amino acid vessels which allow you to perform 880 unattended couplings for maximum production efficiency. The same amino acid can be assigned to multiple vessels, making this our most versatile instrument. We offer many different volumes including: 10 ml, 45 ml, 90 ml or 250 ml. With our fully customizable software, you can decide whether to use your amino acid vessels for solid amino acids, reagents, or any solution.
5 Accuracy Two preactivation / measuring vessels allow you to precisely measure your solutions at the desired tempreture. Preactivated amino acids or solutions can be efficiently transferred to the RV with our unique delivery system minimizing dead volume. Preactivation You can determine where it would be best to pre-activate your amino acid, either in an amino acid vessel or in one of the two measuring vessels. UV Monitoring Optional UV monitoring of Fmoc-deprotection detects slow deprotection reactions and automatically extends reaction time to assure maximum Fmoc removal and higher yield. Crude Peptide Quality Below are the HPLC and MS analyses of six crude peptides prepared on the Infinity These peptides were synthesized using a combination of ambient temperature and microwave conditions. We only applied microwave heating in hydrophobic sequences. Reactor 1 Reactor 3 Reactor 5 Reactor 2 Reactor 4 Reactor 6 MS and HPLC profile of crude peptides from 6 reactors
6 Specifications On-demand microwave heating for difficult sequences Mixing: Mechanical and/or nitrogen bubbling Reaction Vessels: 1, 2 (Standard), 4, or 6 Reaction Vessel Volume: 5 ml, 25 ml, 50 ml (Standard), 100 ml, or 300 ml Amino Acid/Reagent Vessels: 24 Amino Acid/Reagent Vessel Volume: 90 ml (Standard) or 250 ml Preactivation/Measuring Vessels: 2 Preactivation/Measuring Vessels: 45mL (Standard) or 90 ml 6 solvent and reagent bottles (two 2L, two 1L and two 500 ml) Waste Containers: One 5-gallon container (Option: 2 containers) Weight 85lbs (38.6kg) Width 32in (81cm) Depth 26in (66cm) Height 30in (76cm) Additional Options Optional rapid cooling for precision temperature control Optional UV monitoring On-instrument cleavage Heating Process Temperature Range: Room temperature to 80 C, (optional cooling to -10 C) Pressure Range: Atmospheric pressure Power Range: watts Customer Requirements Nitrogen: The Infinity 2400 requires a 10-psi nitrogen source Self-contained, no hood required 1 Year limited parts and labor warranty Copy Write Protected 6309 Shepherdsville Road Louisville, KY , U.S.A. Phone: Toll-free: Fax: info@aapptec.com
Focus Series Peptide Synthesizers
Focus Series Peptide Synthesizers aapptec is well known for its innovation and leadership in automated peptide synthesizers. aapptec technology has been an industry leader for the past 30 years around
More informationPS3. Peptide Synthesizer.
PS3 Peptide Synthesizer www.gyrosproteintechnologies.com PS3 Peptide Synthesizer It s easier than ever to put automated peptide synthesis capacity in your laboratory! Three reaction vessels Standard or
More informationl 4-minute cycle time l 90% solvent reduction Remarkably fast Automated Microwave Peptide Synthesizer
Automated Microwave Peptide Synthesizer CEM is transforming the way chemists perform peptide synthesis once again with the introduction of the Liberty Blue Microwave Peptide Synthesizer. More than just
More informationPerseverance. Experimentation. Knowledge.
2410 Intuition. Perseverance. Experimentation. Knowledge. All are critical elements of the formula leading to breakthroughs in chemical development. Today s process chemists face increasing pressure to
More informationDr. OligoTM DNA / RNA / OLIGO SYNTHESIZERS
Dr. OligoTM DNA / RNA / OLIGO SYNTHESIZERS High Throughput Oligo Synthesis Synthesize Cleave Deprotect Desalt Elute Dr. Oligo TM The Dr. Oligo TM High Throughput Oligo Synthesizer is available in four
More informationLABOTRON EXTRACTION & SYNTHESIS 2450 MHz
LABOTRON EXTRACTION & SYNTHESIS 2450 MHz The LABOTRON TM series is the generic name for a ground breaking range of integrated reactor and microwave transmission systems especially designed to carry out
More informationINNOVATIVE ENGINEERING FOR SIMPLE OPERATION
THE BEST-SELLING MICROWAVE SYNTHESIS PLATFORM takes another leap forward with Discover SP. This new system has all of the features for which the Discover series is known, plus an enhanced heating capability,
More informationMicrowave-Enhanced Solid Phase Peptide Synthesis. Jonathan M. Collins Bioscience Division CEM Corporation
Microwave-Enhanced Solid Phase Peptide Synthesis Jonathan M. Collins Bioscience Division CEM Corporation Microwave SPPS Reaction Vessel Standard Microwave Fmoc SPPS Parameters Deprotection Time Temperature
More informationRapid Microwave-Assisted CNBr Cleavage of Bead-Bound Peptides
Rapid Microwave-Assisted CNBr Cleavage of Bead-Bound Peptides Su Seong Lee 1,*, Jaehong Lim 1, Junhoe Cha 1, Sylvia Tan 1, James R. Heath 1,2, * 1 Institute of Bioengineering and Nanotechnology, 31 Biopolis
More informationINNOVATIVE ENGINEERING FOR SIMPLE OPERATION
THE BEST-SELLING MICROWAVE SYNTHESIS PLATFORM takes another leap forward with Discover SP. This new system has all of the features for which the Discover series is known, plus an enhanced heating capability,
More informationLiberty Blue TM Automated Microwave Peptide Synthesizer. Manual
Liberty Blue TM Automated Microwave Peptide Synthesizer Manual Contents Introduction About the Instrument 1 Common Abbreviations and Units 1 Liberty Method Editor 22 Calculators 28 Edit Users and User
More informationFusion UV/Persulfate TOC Analyzer
Fusion UV/Persulfate TOC Analyzer The Fusion Total Organic Carbon (TOC) Analyzer utilizes powerful Ultra Violet (UV) Persulfate oxidation allowing superior carbon liberation from even the most challenging
More informationAstoria-Pacific proudly offers our rapid-t software for the ChemWell-T an easy-to-use, compact automated chemistry analyzer:
ASTORIA-PACIFIC rapid-t with Astoria-Pacific proudly offers our rapid-t software for the ChemWell-T an easy-to-use, compact automated chemistry analyzer: Durable. Accurate. Precise. Economical Open software
More informationION CHROMATOGRAPHY SYSTEM S 150
ION CHROMATOGRAPHY SYSTEM S 150 WATER ANALYSIS ENVIRONMENTAL ANALYSIS ANION & CATION ANALYSIS ION CHROMATOGRAPHY IIon Chromatography is an analytical separation technique based on ionic interactions. Dissolved
More informationAn automated synthesis programme for drug discovery
An automated synthesis programme for drug discovery Automation has revolutionised the way that organic synthesis is performed in the research laboratory. Dr James Harness, Bohdan Automation Inc Combinatorial
More informationFusion UV/Persulfate TOC Analyzer
www.ietltd.com Proudly serving laboratories worldwide since 1979 CALL +847.913.0777 for Refurbished & Certified Lab Equipment Fusion UV/Persulfate TOC Analyzer The Fusion Total Organic Carbon (TOC) Analyzer
More informationSupporting Information
Electronic upplementary Material (EI) for ChemComm. This journal is The Royal ociety of Chemistry 2014 upporting Information Materials and methods: Chemicals: Fmoc-amino acids were obtained from GL Biochem
More informationUniversity Wet Chemistry Analyzer Packages
University Wet Chemistry Analyzer Packages University laboratories and public research institutions have a special place in the scientific community. Often they are tasked with undertaking basic research
More informationMicrowave Synthesis Solutions. ::: Excellence in Microwave Synthesis
Microwave Synthesis Solutions ::: Excellence in Microwave Synthesis The Complete Family: Microwave Synthesis Since its beginning in 1986, microwave synthesis has successfully matured, particularly within
More informationLevel. Automate your processes Automate your lab Innovate with. sensing. EasyPREP. sample handler. Automated Sample Preparation.
Automate your processes Automate your lab Innovate with EasyPREP sample handler Automated Sample Preparation Dispense up to 7 reagents Dilute Samples Aliquote Samples Transfer Samples Normalize Samples
More informationPure Chromatography Consumables Pure flexibility. Pure specialization. Pure convenience.
Pure Chromatography Consumables Pure flexibility. Pure specialization. Pure convenience. Pure Consumables More focus on your application The Pure consumable portfolio offers an unrivaled range of products
More informationKjeltec 2300 Analyzer Unit
Kjeltec 2300 Analyzer Unit Automatic distillation and approved colorimetric titration for analysis of Kjeldahl nitrogen/protein, ammonium- nitrogen, TKN, Direct distillation (DD), volatile acids/ bases
More informationContinuous Flow-based Solid-phase Peptide Synthesiser
Continuous Flow-based Solid-phase Peptide Synthesiser Introduction As mainstream drug discovery is starting to shift from small molecules to peptide-based therapeutics, there is a growing demand for high
More informationHigh-Performance Continuous Flow Chemistry Systems. Robust Accurate Flexible Safe
High-Performance Continuous Flow Chemistry Systems Robust Accurate Flexible Safe Flow chemistry systems from Uniqsis Uniqsis designs and manufactures of a range of bench top continuous flow chemistry systems
More informationFor Excellence in Organic Chemistry
Organix Inc. Your Contract Research and Custom Synthesis Company www.organixinc.com For Excellence in Organic Chemistry Organix Inc. A Contract Research and Custom Synthesis Company At the discovery end
More informationSUPPORTING INFORMATION. Elevated Temperatures A Critical Comparison of
S1 SUPPORTING INFORMATION Solid-Phase Synthesis of Difficult Peptide Sequences at Elevated Temperatures A Critical Comparison of Microwave and Conventional Heating Technologies Bernadett Bacsa, Kata Horváti,
More informationDO I REALLY NEED TO USE MICROWAVE TECHNOLOGY? IF YOU WORK WITH ANY TYPE OF CHEMICAL SYNTHESIS OR CHEMICAL REACTION, THE ANSWER IS YES!
DO I REALLY NEED TO USE MICROWAVE TECHNOLOGY? IF YOU WORK WITH ANY TYPE OF CHEMICAL SYNTHESIS OR CHEMICAL REACTION, THE ANSWER IS YES! Microwave synthesis is a well-accepted technique used by research
More informationASTORIA PACIFIC. Automated Wet-Chemistry Analyzers and Diagnostic Reagents. rapid-t
ASTORIA PACIFIC Automated Wet-Chemistry Analyzers and Diagnostic Reagents rapid-t rapid-t System ASTORIA-PACIFIC PROUDLY OFFERS OUR rapid-t SYSTEM: Durable. Accurate. Precise. Economical. Open software
More informationPeptide Isolation Using the Prep 150 LC System
Jo-Ann M. Jablonski and Andrew J. Aubin Waters Corporation, Milford, MA, USA APPLICATION BENEFITS The Prep 150 LC System, an affordable, highly reliable system for preparative chromatography, is suitable
More informationGeneral methods. RP-HPLC and LC-MS
Electronic Supplementary Material (ESI) for Organic & Biomolecular Chemistry. This journal is The Royal Society of Chemistry 2017 General methods Materials All reagents were acquired as reagent grade from
More informationSelf-Assembly of Single Amino acid-pyrene Conjugates with Unique Structure-Morphology Relationship
Electronic Supplementary Material (ESI) for Soft Matter. This journal is The Royal Society of Chemistry 2017 Self-Assembly of Single Amino acid-pyrene Conjugates with Unique Structure-Morphology Relationship
More informationFlowSyn The Continuous Flow Reactor from Uniqsis Designed by chemists for chemists
FlowSyn The Continuous Flow Reactor from Uniqsis Designed by chemists for chemists FlowSyn range overview MeO At the forefront of flow reactor design, FlowSyn is the platform of choice within major pharmaceutical
More informationSUPPORTING INFORMATION
Dynamic covalent templated-synthesis of [c2]daisy chains. Altan Bozdemir, a Gokhan Barin, a Matthew E. Belowich, a Ashish. Basuray, a Florian Beuerle, a and J. Fraser Stoddart* ab a b Department of Chemistry,
More informationSupporting Information for. PNA FRET Pair Miniprobes for Quantitative. Fluorescent in Situ Hybridization to Telomeric DNA in Cells and Tissue
Supporting Information for PNA FRET Pair Miniprobes for Quantitative Fluorescent in Situ Hybridization to Telomeric DNA in Cells and Tissue Orenstein, et al Page S2... PNA synthesis procedure Page S3...
More informationH E L P I N G C H E M I S T S. UltraCLAVE. The Next Generation Microwave Digestion System
H E L P I N G C H E M I S T S UltraCLAVE The Next Generation Microwave Digestion System UltraCLAVE The Next Generation Microwave Digestion System Improving upon an established technology is always a challenge.
More informationSyro Wave Microwave & Parallel Peptide Synthesizer - The Best of Both Worlds
The New Syro Wave Microwave & Parallel Peptide Synthesizer - The Best of Both Worlds Biotage Lunch Seminar 5 th IPS/47 th JPS, Kyoto Dec 5 th 2010 Amit Mehrotra PhD Marketing Manager Peptide Chemistry
More informationSupporting Information
Supporting Information An Extremely Active and General Catalyst for Suzuki Coupling Reactions of Unreactive Aryl Chlorides Dong-Hwan Lee and Myung-Jong Jin* School of Chemical Science and Engineering,
More informationBiotage 2012 Webinar series
Biotage 2012 Webinar series Title: Isolera Spektra - A Revolution in Intelligent Flash Chromatography Date: 13 th June 2012 Summary: Automated flash has until today been based upon simple evolutionary
More informationSupplementary Material Novel phosphopeptides as surface-active agents in iron nanoparticle synthesis
10.1071/CH12168_AC CSIRO 2012 Australian Journal of Chemistry 2012, 65(6), 680 685 Supplementary Material Novel phosphopeptides as surface-active agents in iron nanoparticle synthesis Raoul Peltier, A,D
More informationSupporting Information
Supporting Information An efficient and general method for the Heck and Buchwald- Hartwig coupling reactions of aryl chlorides Dong-Hwan Lee, Abu Taher, Shahin Hossain and Myung-Jong Jin* Department of
More informationMicrowave-Assisted Biginelli Reaction
Boston University penbu Chemistry http://open.bu.edu rganic Chemistry Laboratory Experiments 2011-07-14 Microwave-Assisted Biginelli Reaction Mulcahy, Seann P. https://hdl.handle.net/2144/1416 Boston University
More informationLiberty Blue TM Automated Microwave Peptide Synthesizer. User Guide
Liberty Blue TM Automated Microwave Peptide Synthesizer User Guide WARNING Handle all chemicals under a fume hood, and wear suitable protective clothing such as safety glasses, chemical resistant gloves,
More informationThermo Scientific Orion Star T900 Series Laboratory Titrators. Potentiometric titrators for performing automated ph, redox, or ion titrations
Thermo Scientific Orion Star T900 Series Laboratory Titrators Potentiometric titrators for performing automated ph, redox, or ion titrations Thermo Scientific Orion Star T900 Series Titrators Automate
More informationaapptec 2. Set up a flask with a heating mantle and thermometer on an orbital shaker.
aapptec Technical Support Information Bulletin 1048 Merrifield Resin Merrifield resin is the common name for chloromethylated polystyrene crosslinked with 1-2% divinylbenzene (DVB). It is named for the
More informationElectronic Supplementary Information
This journal is (c) The Royal Society of Chemistry 29 1 Electronic Supplementary Information On the importance of simultaneous infrared/fiber-optic temperature monitoring in the microwave-assisted synthesis
More informationSOPHAS - Speeding up the process of discovery and optimisation
SOPHAS Automated System For Any Synthesis Application SOPHAS - Speeding up the process of discovery and optimisation The SOPHAS system is an automatic system for synthesis and sample preparation that comprises
More informationApplication Note LCMS-112 A Fully Automated Two-Step Procedure for Quality Control of Synthetic Peptides
Application Note LCMS-112 A Fully Automated Two-Step Procedure for Quality Control of Synthetic Peptides Abstract Here we describe a two-step QC procedure for synthetic peptides. In the first step, the
More informationC80. Calvet Calorimeter From ambient to 300 C. A trademark of KEP Technologies group
C80 Calvet Calorimeter From ambient to 300 C A trademark of KEP Technologies group C80 SENSOR The C80 Calorimeter is one of the most powerful, yet flexible calorimeters available. The high precision Calvet
More informationSupporting Information For:
Supporting Information For: Peptidic α-ketocarboxylic Acids and Sulfonamides as Inhibitors of Protein Tyrosine Phosphatases Yen Ting Chen, Jian Xie, and Christopher T. Seto* Department of Chemistry, Brown
More informationAMP + MaxSpec Kit. Item No Customer Service Technical Support
AMP + MaxSpec Kit Item No. 710000 www.caymanchem.com Customer Service 800.364.9897 Technical Support 888.526.5351 1180 E. Ellsworth Rd Ann Arbor, MI USA TABLE OF CONTENTS GENERAL INFORMATION 3 Materials
More informationSupporting Information for: Using a Lipase as a High Throughput Screening Method for Measuring the Enantiomeric. Excess of Allylic Acetates
Supporting Information for: Using a Lipase as a High Throughput Screening Method for Measuring the Enantiomeric Excess of Allylic Acetates M. Burak Onaran and Christopher T. Seto* Department of Chemistry,
More informationPART I: Chemfile Creations:
This is created by Bingyun Li. It is only for reference. The instrument is Advanced ChemTech Apex 396.
More informationIT DOESN T GET ANY EASIER THAN THIS!
IT DOESN T GET ANY EASIER THAN THIS! Each sample vial is run under full pressure and temperature control. Different samples can be run sequentially with different reagents and methodologies and different
More informationOligo Click S ROTI kit for DNA labeling
USER MANUAL Oligo Click S ROTI kit for DNA labeling ROTI kit for DNA labeling Carl Roth GmbH + Co. KG Oligo Click S ROTI kit for DNA labeling For Click Chemistry labeling of up to 10 nmol oligonucleotide
More informationKalexsyn Overview Kalexsyn, Inc Campus Drive Kalamazoo, MI Phone: (269) Fax: (269)
Kalexsyn verview 2017 Kalexsyn, Inc. 4502 Campus Drive Kalamazoo, MI 49008 Phone: (269) 488-8488 Fax: (269) 488-8490 info@kalexsyn.com What we are Experienced medicinal chemists Conception and synthesis
More informationOligo Click M Reload ROTI kit for DNA labeling
USER MANUAL Oligo Click M Reload ROTI kit for DNA labeling ROTI kit for DNA labeling Carl Roth GmbH + Co. KG Oligo Click M Reload ROTI kit for DNA labeling For Click Chemistry labeling of up to 100 nmol
More informationElectronic Supplementary Information
Electronic Supplementary Information General and highly active catalyst for mono and double Hiyama coupling reactions of unreactive aryl chlorides in water Dong-Hwan Lee, Ji-Young Jung, and Myung-Jong
More informationSIMPLICITY AND TECHNOLOGY THE LIASYS CLINICAL CHEMISTRY SYSTEMS FOR PHYSICIAN OFFICE LABORATORIES
SIMPLICITY AND TECHNOLOGY THE LIASYS CLINICAL CHEMISTRY SYSTEMS FOR PHYSICIAN OFFICE LABORATORIES INNOVATIVE AND COST-SAVING TECHNOLOGIES AT YOUR SERVICE DISTRIBUTED BY LIASYS MODELS LIASYS 330 - for POL
More informationImmobilized and Reusable Cu(I) Catalyst for Metal Ion-Free Conjugation of Ligands to Fully Deprotected Oligonucleotides through Click Reaction
This journal is The Royal Society of Chemistry 213 Immobilized and Reusable Cu(I) Catalyst for Metal Ion-Free Conjugation of Ligands to Fully Deprotected Oligonucleotides through Click Reaction Laxman
More informationDrug Testing Solutions INDIKO DRUG TESTING ANALYZER. 1 P F
Drug Testing Solutions INDIKO DRUG TESTING ANALYZER 1 www.dtpm.ws P. 256-845-1261 F. 888-317-4178 sales@dtpm.ws Overview Indiko Sample oriented random access system for clinical and specialty testing,
More informationProtein Sequencer PPSQ-31A / 33A C297-E055B
Protein Sequencer PPSQ-31A / 33A C297-E055B Protein Sequencer PPSQ-31A / 33A Achieving Greater Simplicity and Reliability in the Determination of Amino Acid Sequences Analytical Stability Excellent baseline
More informationComparing the MICROLAB 600 to Volumetric Glassware and Air Displacement Pipettes. June 2011
Comparing the MICROLAB 600 to tric Glassware and Air Displacement Pipettes June 2011 tric Glassware and Air Displacement Pipettes Table of Contents ``Abstract...3 ``Introduction...4 ``Method & Results...5
More informationDesign for Environment : Green Chemistry Principles for Product Design
Design for Environment : Green Chemistry Principles for Product Design ecologic Technologies Ltd We shall require a substantially new manner of thinking if mankind is to survive. Transforming industrial
More informationTransferring HPLC methods from the HP 1090 Series to the Agilent 1100 Series HPLC system
Transferring HPLC methods from the HP 1090 Series to the Agilent 1100 Series HPLC system Technical Note Introduction The HP 1090 Series HPLC system, introduced in 1983, is regarded to be an outstanding
More informationSUPPLEMENTARY INFORMATION
DOI: 10.1038/NCHEM.2633 Mechanically controlled radical polymerization initiated by ultrasound Hemakesh Mohapatra, Maya Kleiman, Aaron P. Esser-Kahn Contents 1. Materials and methods 2 2. Procedure for
More informationDI 3500 Discrete Aoalvzer
DI 3500 Discrete Aoalvzer Automated Chemistry and Ion Analysis ':t O+Analytical:!, A World ofsolutions. - Discrete Analysis Efficient Microscale Chemistry Increasingly laboratories are being challenged
More informationThe Depsipeptide Methodology for Solid Phase Peptide Synthesis: Circumventing Side Reactions and Development of an Automated Technique via
Supporting Information The Depsipeptide Methodology for Solid Phase Peptide Synthesis: Circumventing Side Reactions and Development of an Automated Technique via Depsidipeptide Units. Irene Coin, Rudolf
More informationAdvancer Kilobatch. kilogram scale-up of all microwave chemistry
Advancer Kilobatch kilogram scale-up of all microwave chemistry Background MW reactions are become more common place in Discovery / Med Chem MW reactions can be higher yield / higher purity MW reactions
More informationProduct Information. Silicon Carbide Well Plates
Silicon Carbide Well Plates Silicon carbide (SiC) is the perfect material to ensure temperature homogeneity in rectangular multiwell reactors in a microwave field. The high microwave absorbance and excellent
More informationSYNCHROM EVO III. Choose your application of. Syn. processowner. runtime min. tracer reaction reactor purification. radiochemical.
www.raytest.com Choose your application of SYNCHROM EVO III 131 / 123 I-MIBG labeling nucleophilic 68 Ga-DOTATOC labeling complexation tracer reaction reactor purification processowner radiochemical yield
More informationAutomated pipetting made easy new ep Motion 5073 family members for perfect PCR set-up and nucleic acids purifi cation or general liquid handling
Ready, Set, Prep Automated pipetting made easy new epmotion 5073 family members for perfect PCR set-up and nucleic acids purification or general liquid handling 2 Eppendorf epmotion Eppendorf epmotion
More informationUnparalleled Peptide Synthesis. cempeptides.com
Unparalleled Peptide Synthesis cempeptides.com Contents CEM Overview 2 Innovations in Microwave Peptide Synthesis 2 Founding Fathers 3 Corporate Legacy Chemistry Technologies 4 HE-SPPS 6 CarboMAX TM 8
More informationdata sheet DONATELLO FAST General characteristics Rev. First emission - 01/07/ PRO02 code
DONATELLO FAST Automatic floor closed cycle tissue processor for histological specimens Automatic tissue processor for histological specimens DONATELLO FAST code PRO0 RI General characteristics DONATELLO
More informationSupporting Information
Electronic Supplementary Material (ESI) for ChemComm. This journal is The Royal Society of Chemistry 2014 Supporting Information Tuning the Thermosensitive Properties of Hybrid Collagen Peptide-Polymer
More informationSUPPORTING INFORMATION
SUPPRTIG IFRMATI Salicylaldehyde Ester-Induced Chemoselective Peptide Ligations Enabling Generation of atural Peptidic Linkages at the Serine/Threonine Sites Xuechen Li,* iu Yung Lam, Yinfeng Zhang, Chun
More informationSupporting Information
Supporting Information Novel diphenylmethyl-derived amide protecting group for efficient liquid-phase peptide synthesis; AJIPHASE Daisuke Takahashi*, Tatsuya Yano and Tatsuya Fukui Research Institute For
More informationLinear Dependence of Water Proton Transverse Relaxation Rate on Shear Modulus in Hydrogels
Electronic Supplementary Material (ESI) for ChemComm. This journal is The Royal Society of Chemistry 214 ESI (Electronic Support Information) Linear Dependence of Water Proton Transverse Relaxation Rate
More informationTHE VERSATILE VSP2: A TOOL FOR ADIABATIC THERMAL ANALYSIS AND VENT SIZING APPLICATIONS
THE VERSATILE VSP2: A TOOL FOR ADIABATIC THERMAL ANALYSIS AND VENT SIZING APPLICATIONS Charles F. Askonas, Dr. James P. Burelbach, and Dr. Joseph C. Leung Fauske and Associates, Inc. 16W070 W. 83 rd Street
More informationHigh Pressure Chemistry. Hydrogenation & Catalysis Tools.
High Pressure Chemistry Hydrogenation & Catalysis Tools www.helgroup.com HYDROGENATION AND CATALYSIS Product Selection Guide HEL Group s top quality high pressure reactors and systems offer innovative,
More informationAutomating Wet Chemical Analysis. William Lipps Market Specialist for Water Analyzer Products December 11, 2008
Automating Wet Chemical Analysis William Lipps Market Specialist for Water Analyzer Products December 11, 2008 The advantages of automating wet chemical analysis. Save time Decrease cost Improve quality
More informationMetz Syn 10 Reaction Station
Metz Syn 10 Reaction Station For parallel chemistry, process development and reaction optimisation Simultaneously carry out 10 reactions, but each with a different temperature, from -30 C to +150 C...
More informationSupporting Information
S1 Microwave-Assisted Synthesis of Isonitriles: A General Simple Methodology Andrea Porcheddu,* Giampaolo Giacomelli, and Margherita Salaris Dipartimento di Chimica, Università degli Studi di Sassari,
More informationPostsynthetic modification of unprotected peptides via S-tritylation reaction
Supporting Information Postsynthetic modification of unprotected peptides via S-tritylation reaction Masayoshi Mochizuki, Hajime Hibino and Yuji Nishiuchi *,, SAITO Research Center, Peptide Institute,
More informationApplication Note. Abstract. Introduction. Experimental-Instrument Conditions. By: Anne Jurek
Requirements of an Automated Sample Delivery System in Today s Realm of Ever Increasing Sensitivity Demands Utilizing the Atomx Concentrator/Multimatrix Autosampler. Application Note By: Anne Jurek Abstract
More informationOral Fluid (Saliva) Collection Device
Versi. SAL 1 Oral Fluid (Saliva) Collection Device Instructions for Use Versi. SAL 1 Oral Fluid (Saliva) Collection Device Sample Sufficiency Indicator Collector Handle Assembly Absorbent Collector Pad
More informationStructure-activity effects in peptide self-assembly and gelation Dendritic versus linear architectures
Structure-activity effects in peptide self-assembly and gelation Dendritic versus linear architectures Cecile A. Lagadec a and David K. Smith*,a SUPPLEMETARY IFRMATI Contents 1 General Experimental Methods
More informationThe first address for Titration. TITRONIC 300 and TitroLine 5000
The first address for Titration TITRONIC 300 and TitroLine 5000 Selection table titration piston burettes TITRONIC and automatic titrators TitroLine The most important features of titrators TitroLine and
More informationABI 3200 Q TRAP LC/MS/MS System
www.ietltd.com Proudly serving laboratories worldwide since 1979 CALL 001.847.913.0777 ABI 3200 Q TRAP LC/MS/MS System The advantages of an ion trap and the performance of a triple quad. All in one system.
More informationAGrignard reaction, in which a reactant, A, is coupled with phenyl magnesium chloride, is used to
DEVELOPMENT OF AN EFFICIENT AND SAFE PROCESS FOR A GRIGNARD REACTION VIA REACTION CALORIMETRY H. Ferguson and Y. M. Puga The Dow Chemical Co., Inc. Engineering Sciences/Market Development A paper from
More informationDSA 5000 M. Density and Sound Velocity Meter. ::: Unique Density & Concentration Meters
DSA 5000 M Density and Sound Velocity Meter ::: Unique Density & Concentration Meters From 0 to 114 % in 2 Minutes DSA 5000 M determines the concentration of sulfuric acid and oleum across the whole concentration
More informationSpeed and flexibility
Speed and flexibility Automate your environmental, water, detergent, food and beverage analysis Thermo Scientific Gallery and Gallery Plus discrete industrial analyzers Improve productivity, reproducible
More informationElectronic Supplementary Information for
Electronic Supplementary Information for Sequence Selective Dual-Emission Detection of (i, i+1) Bis-Phosphorylated Peptide Using Diazastilbene-Type Zn(II)-Dpa Chemosensor Yoshiyuki Ishida, Masa-aki Inoue,
More informationWhy teach with a laboratory microwave?
Why teach with a laboratory microwave? Bring real world experience into the teaching laboratory with state-of-the-art tools like the ones your students will encounter in graduate school and the workplace.
More informationSupporting Information
Supporting Information Experimental Section Azido Acids General: Triflyl anhydride and Cu II S pentahydrate 99.999% were obtained from Aldrich. All other solvents and chemicals were reagent grade or better
More informationAUTOMATED CHROMATOGRAPHY SYSTEMS. Featuring EZ Prep
AUTOMATED CHROMATOGRAPHY SYSTEMS Featuring EZ Prep CombiFlash EZ Prep built on a strong history of chromatography innovations The CombiFlash EZ Prep system is the latest innovation from Teledyne Isco.
More informationManual Solid Phase Peptide Synthesis Protocol (modified 12/14/16)
Manual Solid Phase Peptide Synthesis Protocol (modified 12/14/16) With FMOC amino acids Excellent video: https://www.youtube.com/watch?v=jvxufc2plh4 https://www.youtube.com/watch?v=9zsronmi53m Homemade
More informationReal-time In Situ FTIR Reaction Analysis Evolution of Technology Current State-of-the-Art. July 23, 2009 CPAC Summer Institute Seattle, WA
Real-time In Situ FTIR Reaction Analysis Evolution of Technology Current State-of-the-Art July 23, 2009 CPAC Summer Institute Seattle, WA Evolution of Reaction Analysis Technologies Optical modules - Interferometer
More informationبه نام خدا. New topics in. organic chemistry. Dr Morteza Mehrdad University of Guilan, Department of Chemistry, Rasht, Iran
به نام خدا New topics in 2 organic chemistry Dr Morteza Mehrdad University of Guilan, Department of Chemistry, Rasht, Iran m-mehrdad@guilan.ac.ir Combinatorial chemistry 1 http://www.combichemistry.com/
More informationTHE NEW MILESTONE MILESTONE
M I C R O W A V E E X T R A C T I O N S Y S T E M THE NEW MILESTONE MILESTONE Invest in better data. Modern analytical instrumentation such as HPLC, GC, and GC-MS is capable of extremely precise measurement.
More informationMOBILE SURFACE ANALYZER MSA MOBILE MEASUREMENT OF SURFACE FREE ENERGY WITH ONLY ONE CLICK
MOBILE SURFACE ANALYZER MSA MOBILE MEASUREMENT OF SURFACE FREE ENERGY WITH ONLY ONE CLICK WE RE SETTING NEW STANDARDS FOR QUALITY CONTROL WITH THE MOBILE MEASUREMENT OF SURFACE FREE ENERGY One-click measurement
More information