ICP Test Report Certification Packet
|
|
- Jemimah Roberts
- 5 years ago
- Views:
Transcription
1 ICP Test Report Certification Packet Company name: Suzhou Good-Ark Electronics Co.,Ltd. Product Series: SMB SMC Series Product #: SMX GPP(TVS) Diode Issue Date: Sep 1, 2012 It is hereby certified by Suzhou Goodark Electronics CO.,Ltd. that there is neither RoHS (EU Directive 2002/95/EC)-restricted substance nor such use, for materials to be used for unit parts, for packing/packaging materials, and for additives and the like in the manufacturing processes. In addition, it is hereby reported to you that the parts and sub-materials, the materials to be used for unit parts, the packing/packaging materials, and the additives and the like in the manufacturing processes, are all composed of the following components. Issued by: Global EHS Engineer (1) Parts, sub-materials and unit parts This document covers the SMB SMC Series RoHS-Compliant series products manufactured by Littelfuse, Inc. <Raw Materials Used Please see Table 1 > (2) The ICP data on all measurable substances Please see appropriate pages as identifed in Table 1 Remarks:under RoHS Exemptions 5 (7c-1 in the New RoHS exemption) and 7a apply to these products. Rev. A 09/01/12 Page 1
2 Table 1: List of Raw Materials covered by this report Total Parts Raw Material Description Test Ruesult Page(s) 1 Lead Frame 2 Dice 3 Solder Chip 4 Molding Compound 5 Halogen free Molding compound 6 Plating Cd: Pb: Hg: Cr6+:N PBBs: PBDEs: Cd: Pb:44347 Hg: Cr6+:N PBBs: PBDEs: Cd: Pb: Hg: Cr6+:N PBBs: PBDEs: Cd: Pb: Hg: Cr6+: PBBs: PBDEs: Cd: Pb: Hg: Cr6+: PBBs: PBDEs: F: Cl:89 Br: I: Cd: Pb:230 Hg: Cr6+:N PBBs: PBDEs: Page 2
3 WUXH Applicant : SUZHOU GOODARK ELECTRONICS CO., LTD. Date : Jul 26, 2012 NO.31 TONGXI ROAD, TONGAN ECONOMIC DEVELOPMENT ZONE, SUZHOU, P.R.CHINA Attn : MIAO XIAOQING Sample Description As Declared: One (1) Piece Of Submitted Sample Said To Be : Copper Metal. Sample Item : Lead Frame. Material Spec : C1921. Remark : As Requested By The Applicant, Tested As A Whole And Sampled Randomly. Tests Conducted: As Requested By The Applicant, For Details Refer To Attached Pages Prepared And Checked By: For Jessica Lu General Manager Page 1 Of 5
4 WUXH RoHS Directives Test (A) Test Result Summary: Testing Item Cadmium (Cd) Content (mg/kg) Lead (Pb) Content (mg/kg) Mercury (Hg) Content (mg/kg) Chromium (VI)(Cr 6+ ) Result (By Boiling Water Extraction On Metal) (mg/kg With 50cm 2 ) Polybrominated Biphenyls (PBBs)(mg/kg) Monobrominated Biphenyls (MonoBB) Dibrominated Biphenyls (DiBB) Tribrominated Biphenyls (TriBB) Tetrabrominated Biphenyls (TetraBB) Pentabrominated Biphenyls (PentaBB) Hexabrominated Biphenyls (HexaBB) Heptabrominated Biphenyls (HeptaBB) Octabrominated Biphenyls (OctaBB) Nonabrominated Biphenyls (NonaBB) Decabrominated Biphenyl (DecaBB) Polybrominated Diphenyl Ethers (PBDEs)(mg/kg) Monobrominated Diphenyl Ethers (MonoBDE) Dibrominated Diphenyl Ethers (DiBDE) Tribrominated Diphenyl Ethers (TriBDE) Tetrabrominated Diphenyl Ethers (TetraBDE) Pentabrominated Diphenyl Ethers (PentaBDE) Hexabrominated Diphenyl Ethers (HexaBDE) Heptabrominated Diphenyl Ethers (HeptaBDE) Octabrominated Diphenyl Ethers (OctaBDE) Nonabrominated Diphenyl Ethers (NonaBDE) Decabrominated Diphenyl Ether (DecaBDE) Result N Remark: mg/kg = Milligram Per Kilogram = ppm mg/kg With 50cm 2 = Milligram Per Kilogram With 50 Square Centimeter = Not Detected N=Negative Page 2 Of 5
5 WUXH (B)RoHS Requirement: Restricted Substances Limits Cadmium (Cd) 0.01% (100 mg/kg) Lead (Pb) Mercury (Hg) Chromium (VI) (Cr 6+ ) Polybrominated Biphenyls (PBBs) Polybrominated Diphenyl Ethers (PBDEs) The Above Limits Were Quoted From 2002/95/EC And Amendment 2005/618/EC For Homogeneous Material. (C) Test Method: Testing Item Testing Method Reporting Limit Cadmium (Cd)Content Lead (Pb)Content Mercury (Hg)Content Chromium (VI) (Cr 6+ ) Content (For Metal) Polybrominated Biphenyls (PBBs)& Polybrominated Diphenyl Ethers (PBDEs) Date Sample Received: Jul 20, 2012 Testing Period: Jul 20, 2012To Jul 26, 2012 With Reference To IEC Edition 1.0: 2008, By Acid Digestion And Determined By ICP-OES With Reference To IEC Edition 1.0: 2008, By Acid Digestion And Determined By ICP-OES With Reference To IEC Edition 1.0: 2008, By Acid Digestion And Determined By ICP-OES With Reference To IEC Edition 1.0: 2008, By Boiling Water Extraction And Determined By UV-VIS Spectrophotometer With Reference To IEC Edition 1.0: 2008, By Solvent Extraction And Determined By GC-MSD And Further HPLC Confirmation When Necessary. 2 mg/kg 2 mg/kg 2 mg/kg 0.02mg/kg With 50cm 2 (In Testing Solution) 5 mg/kg Page 3 Of 5
6 WUXH (D) Measurement Flowchart: Reference Standard: IEC Edition 1.0: 2008 Sampling/Grinding Or Cutting Cd/Pb/Hg Cr 6+ PBBs/PBDEs For Different Material, Digest The Sample With Appropriate Acid *1 Metal Get 50cm 2 Samples Weigh Sample And Add Organic Solvent Confirm The Tested Samples Are Totally Dissolved Yes No Boiling Water Extraction Soxhlet Extraction Or Solvent Extraction Make Up With Deionized Water Analyzed By ICP-OES Make Up With Deionized Water And Add Diphenyl- Carbazide Solution Concentrate The Extract And Make Up With Organic Solvent Analyzed By UV-VIS Analyzed By GC-MSD Chemist: Inorganic (Ann Luo/Fred Wang/Ally Wan) Organic (Jenny Xu/Cherry Sun) Remarks: *1: List Of Appropriate Acid: Material Acid Added For Digestion Polymers HNO 3, HCL,HF,H 2 O 2, H 3 BO 3 Metals HNO 3, HCL,HF Electronics HNO 3, HCL,H 2 O 2, HBF 4 Page 4 Of 5
7 WUXH Photo This report is made solely on the basis of your instructions and/or information and materials supplied by you. It is not intended to be a recommendation for any particular course of action. Intertek does not accept a duty of care or any other responsibility to any person other than the Client in respect of this report and only accepts liability to the Client insofar as is expressly contained in the terms and conditions governing Intertek's provision of services to you. Intertek makes no warranties or representations either express or implied with respect to this report save as provided for in those terms and conditions. We have aimed to conduct the Review on a diligent and careful basis and we do not accept any liability to you for any loss arising out of or in connection with this report, in contract, tort, by statute or otherwise, except in the event of our gross negligence or wilful misconduct. Page 5 Of 5
8
9
10
11
12
13
14
15
16 WUXH Applicant : SUZHOU GOODARK ELECTRONICS CO., LTD. Date : Jul 27, 2012 NO.31 TONGXI ROAD, TONGAN ECONOMIC DEVELOPMENT ZONE, SUZHOU, P.R.CHINA Attn : MIAO XIAOQING Sample Description As Declared: One (1) Piece Of Submitted Sample Said To Be : Silvery Grey Solder Chip. Sample Item : Solder Chip. Material Spec : Pb92.5/Sn5/Ag2.5. Tests Conducted: As Requested By The Applicant, For Details Refer To Attached Pages Prepared And Checked By: For Jessica Lu General Manager Page 1 Of 5
17 WUXH RoHS Directives Test (A) Test Result Summary: Testing Item Result Cadmium (Cd) Content (mg/kg) Lead (Pb) Content (mg/kg) #1 Mercury (Hg) Content (mg/kg) Chromium (VI)(Cr 6+ ) Result (By Boiling Water Extraction On Metal) (mg/kg With 50cm 2 ) N Polybrominated Biphenyls (PBBs)(mg/kg) Monobrominated Biphenyls (MonoBB) Dibrominated Biphenyls (DiBB) Tribrominated Biphenyls (TriBB) Tetrabrominated Biphenyls (TetraBB) Pentabrominated Biphenyls (PentaBB) Hexabrominated Biphenyls (HexaBB) Heptabrominated Biphenyls (HeptaBB) Octabrominated Biphenyls (OctaBB) Nonabrominated Biphenyls (NonaBB) Decabrominated Biphenyl (DecaBB) Polybrominated Diphenyl Ethers (PBDEs)(mg/kg) Monobrominated Diphenyl Ethers (MonoBDE) Dibrominated Diphenyl Ethers (DiBDE) Tribrominated Diphenyl Ethers (TriBDE) Tetrabrominated Diphenyl Ethers (TetraBDE) Pentabrominated Diphenyl Ethers (PentaBDE) Hexabrominated Diphenyl Ethers (HexaBDE) Heptabrominated Diphenyl Ethers (HeptaBDE) Octabrominated Diphenyl Ethers (OctaBDE) Nonabrominated Diphenyl Ethers (NonaBDE) Decabrominated Diphenyl Ether (DecaBDE) Remark: mg/kg = Milligram Per Kilogram = ppm mg/kg With 50cm 2 = Milligram Per Kilogram With 50 Square Centimeter = Not Detected N=Negative #1 = As Claimed By The Declaration Submitted By The Client, The Lead Content Of The Component Is Coming From The Constituent Of High Melting Temperature Type Solders (I.E. Lead Based Alloys Containing 85% By Weight Or More Lead) Only. According To EU RoHS Directive (2002/95/EC) And Its Amendments, Lead In High Melting Temperature Type Solders Of This Component Can Be Exempted. Page 2 Of 5
18 WUXH (B)RoHS Requirement: Restricted Substances Limits Cadmium (Cd) 0.01% (100 mg/kg) Lead (Pb) Mercury (Hg) Chromium (VI) (Cr 6+ ) Polybrominated Biphenyls (PBBs) Polybrominated Diphenyl Ethers (PBDEs) The Above Limits Were Quoted From 2002/95/EC And Amendment 2005/618/EC For Homogeneous Material. (C) Test Method: Testing Item Testing Method Reporting Limit Cadmium (Cd)Content Lead (Pb)Content Mercury (Hg)Content Chromium (VI) (Cr 6+ ) Content (For Metal) Polybrominated Biphenyls (PBBs)& Polybrominated Diphenyl Ethers (PBDEs) Date Sample Received: Jul 20, 2012 Testing Period: Jul 20, 2012 To Jul 26, 2012 With Reference To IEC Edition 1.0: 2008, By Acid Digestion And Determined By ICP-OES With Reference To IEC Edition 1.0: 2008, By Acid Digestion And Determined By ICP-OES With Reference To IEC Edition 1.0: 2008, By Acid Digestion And Determined By ICP-OES With Reference To IEC Edition 1.0: 2008, By Boiling Water Extraction And Determined By UV-VIS Spectrophotometer With Reference To IEC Edition 1.0: 2008, By Solvent Extraction And Determined By GC-MSD And Further HPLC Confirmation When Necessary. 2 mg/kg 2 mg/kg 2 mg/kg 0.02mg/kg With 50cm 2 (In Testing Solution) 5 mg/kg Page 3 Of 5
19 WUXH (D) Measurement Flowchart: Reference Standard: IEC Edition 1.0: 2008 Sampling/Grinding Or Cutting Cd/Pb/Hg Cr 6+ PBBs/PBDEs For Different Material, Digest The Sample With Appropriate Acid *1 Metal Get 50cm 2 Samples Weigh Sample And Add Organic Solvent Confirm The Tested Samples Are Totally Dissolved Yes No Boiling Water Extraction Soxhlet Extraction Or Solvent Extraction Make Up With Deionized Water Analyzed By ICP-OES Make Up With Deionized Water And Add Diphenyl- Carbazide Solution Concentrate The Extract And Make Up With Organic Solvent Analyzed By UV-VIS Analyzed By GC-MSD Chemist: Inorganic (Ann Luo/Fred Wang/Ally Wan) Organic (Jenny Xu/Cherry Sun) Remarks: *1: List Of Appropriate Acid: Material Acid Added For Digestion Polymers HNO 3, HCL,HF,H 2 O 2, H 3 BO 3 Metals HNO 3, HCL,HF Electronics HNO 3, HCL,H 2 O 2, HBF 4 Page 4 Of 5
20 WUXH Photo This report is made solely on the basis of your instructions and/or information and materials supplied by you. It is not intended to be a recommendation for any particular course of action. Intertek does not accept a duty of care or any other responsibility to any person other than the Client in respect of this report and only accepts liability to the Client insofar as is expressly contained in the terms and conditions governing Intertek's provision of services to you. Intertek makes no warranties or representations either express or implied with respect to this report save as provided for in those terms and conditions. We have aimed to conduct the Review on a diligent and careful basis and we do not accept any liability to you for any loss arising out of or in connection with this report, in contract, tort, by statute or otherwise, except in the event of our gross negligence or wilful misconduct. Page 5 Of 5
21 WUXH Applicant : SUZHOU GOODARK ELECTRONICS CO., LTD. Date : Jul 26, 2012 NO.31 TONGXI ROAD, TONGAN ECONOMIC DEVELOPMENT ZONE, SUZHOU, P.R.CHINA Attn : MIAO XIAOQING Sample Description As Declared: One (1) Piece Of Submitted Sample Said To Be : Black Plastic. Sample Item : Molding Compound. Material Spec : EME-1100,EME-1200,EME-2100,EME-2500,EME- 5000N,EME5000VR,EME5051S,EME5500F,EME-5500FL,EME-5500FR,EME- 5961,EME-220L,EC-11,EC-12,ER100,ER200 Series. Tests Conducted: As Requested By The Applicant, For Details Refer To Attached Pages Summary: Tested Sample Standard Result Submitted Sample With Reference To Test Method Of IEC Edition 1.0: 2008 And Maximum Concentration Limits Quoted From RoHS Directives 2002/95/EC And Amendment 2005/618/EC Pass Prepared And Checked By: For Jessica Lu General Manager Page 1 Of 5
22 WUXH RoHS Directives Test (A) Test Result Summary: Testing Item Cadmium (Cd) Content (mg/kg) Lead (Pb) Content (mg/kg) Mercury (Hg) Content (mg/kg) Chromium (VI) (Cr 6+ ) Content (mg/kg)(for Non-Metal) Polybrominated Biphenyls (PBBs)(mg/kg) Monobrominated Biphenyls (MonoBB) Dibrominated Biphenyls (DiBB) Tribrominated Biphenyls (TriBB) Tetrabrominated Biphenyls (TetraBB) Pentabrominated Biphenyls (PentaBB) Hexabrominated Biphenyls (HexaBB) Heptabrominated Biphenyls (HeptaBB) Octabrominated Biphenyls (OctaBB) Nonabrominated Biphenyls (NonaBB) Decabrominated Biphenyl (DecaBB) Polybrominated Diphenyl Ethers (PBDEs)(mg/kg) Monobrominated Diphenyl Ethers (MonoBDE) Dibrominated Diphenyl Ethers (DiBDE) Tribrominated Diphenyl Ethers (TriBDE) Tetrabrominated Diphenyl Ethers (TetraBDE) Pentabrominated Diphenyl Ethers (PentaBDE) Hexabrominated Diphenyl Ethers (HexaBDE) Heptabrominated Diphenyl Ethers (HeptaBDE) Octabrominated Diphenyl Ethers (OctaBDE) Nonabrominated Diphenyl Ethers (NonaBDE) Decabrominated Diphenyl Ether (DecaBDE) Result Remark: mg/kg = Milligram Per Kilogram = ppm = Not Detected Page 2 Of 5
23 WUXH (B)RoHS Requirement: Restricted Substances Limits Cadmium (Cd) 0.01% (100 mg/kg) Lead (Pb) Mercury (Hg) Chromium (VI) (Cr 6+ ) Polybrominated Biphenyls (PBBs) Polybrominated Diphenyl Ethers (PBDEs) The Above Limits Were Quoted From 2002/95/EC And Amendment 2005/618/EC For Homogeneous Material. (C) Test Method: Testing Item Testing Method Reporting Limit Cadmium (Cd)Content Lead (Pb)Content Mercury (Hg)Content Chromium (VI) (Cr 6+ ) Content (For Non-Metal) Polybrominated Biphenyls (PBBs)& Polybrominated Diphenyl Ethers (PBDEs) Date Sample Received: Jul 20, 2012 Testing Period: Jul 20, 2012 To Jul 26,2012 With Reference To IEC Edition 1.0: 2008, By Acid Digestion And Determined By ICP-OES With Reference To IEC Edition 1.0: 2008, By Acid Digestion And Determined By ICP-OES With Reference To IEC Edition 1.0: 2008, By Acid Digestion And Determined By ICP-OES With Reference To IEC Edition 1.0: 2008, By Alkaline Digestion And Determined By UV-VIS Spectrophotometer With Reference To IEC Edition 1.0: 2008, By Solvent Extraction And Determined By GC-MSD And Further HPLC Confirmation When Necessary. 2 mg/kg 2 mg/kg 2 mg/kg 1 mg/kg 5 mg/kg Page 3 Of 5
24 WUXH (D) Measurement Flowchart: Reference Standard: IEC Edition 1.0: 2008 Sampling/Grinding Or Cutting Cd/Pb/Hg Cr 6+ Polymers / Electronics PBBs/PBDEs For Different Material, Digest The Sample With Appropriate Acid *1 Weigh Sample And Add Alkaline Solution Weigh Sample And Add Organic Solvent Confirm The Tested Samples Are Totally Dissolved Yes No Definite Temp. Extraction Soxhlet Extraction Or Solvent Extraction Make Up With Deionized Water Analyzed By ICP-OES Cool And Filter The Extract Make Up With Deionized Water And Add Diphenyl- Carbazide Solution Concentrate The Extract And Make Up With Organic Solvent Analyzed By GC-MSD Analyzed By UV-VIS Chemist: Inorganic (Ann Luo/Fred Wang/Ally Wan) Organic (Jenny Xu/Cherry Sun) Remarks: *1: List Of Appropriate Acid: Material Acid Added For Digestion Polymers HNO 3, HCL,HF,H 2 O 2, H 3 BO 3 Metals HNO 3, HCL,HF Electronics HNO 3, HCL,H 2 O 2, HBF 4 Page 4 Of 5
25 WUXH Photo This report is made solely on the basis of your instructions and/or information and materials supplied by you. It is not intended to be a recommendation for any particular course of action. Intertek does not accept a duty of care or any other responsibility to any person other than the Client in respect of this report and only accepts liability to the Client insofar as is expressly contained in the terms and conditions governing Intertek's provision of services to you. Intertek makes no warranties or representations either express or implied with respect to this report save as provided for in those terms and conditions. We have aimed to conduct the Review on a diligent and careful basis and we do not accept any liability to you for any loss arising out of or in connection with this report, in contract, tort, by statute or otherwise, except in the event of our gross negligence or wilful misconduct. Page 5 Of 5
26 WUXH Applicant : SUZHOU GOODARK ELECTRONICS CO., LTD. Date : Jul 30, 2012 NO.31 TONGXI ROAD, TONGAN ECONOMIC DEVELOPMENT ZONE, SUZHOU, P.R.CHINA Attn : MIAO XIAOQING Sample Description As Declared: One (1) Piece Of Submitted Sample Said To Be : Black Epoxy Resin. Sample Item : Halogen Free Molding Compound. Material Spec : EK-1700G, EK-1700GH, EK-1700GO. Tests Conducted: As Requested By The Applicant, For Details Refer To Attached Pages Summary: Tested Sample Standard Result Submitted Sample With Reference To Test Method Of IEC Edition 1.0: 2008 And Maximum Concentration Limits Quoted From RoHS Directives 2002/95/EC And Amendment 2005/618/EC Pass Prepared And Checked By: For Jessica Lu General Manager Page 1 Of 7
27 WUXH RoHS Directives Test (A) Test Result Summary: Testing Item Cadmium (Cd) Content (mg/kg) Lead (Pb) Content (mg/kg) Mercury (Hg) Content (mg/kg) Chromium (VI) (Cr 6+ ) Content (mg/kg)(for Non-Metal) Polybrominated Biphenyls (PBBs)(mg/kg) Monobrominated Biphenyls (MonoBB) Dibrominated Biphenyls (DiBB) Tribrominated Biphenyls (TriBB) Tetrabrominated Biphenyls (TetraBB) Pentabrominated Biphenyls (PentaBB) Hexabrominated Biphenyls (HexaBB) Heptabrominated Biphenyls (HeptaBB) Octabrominated Biphenyls (OctaBB) Nonabrominated Biphenyls (NonaBB) Decabrominated Biphenyl (DecaBB) Polybrominated Diphenyl Ethers (PBDEs)(mg/kg) Monobrominated Diphenyl Ethers (MonoBDE) Dibrominated Diphenyl Ethers (DiBDE) Tribrominated Diphenyl Ethers (TriBDE) Tetrabrominated Diphenyl Ethers (TetraBDE) Pentabrominated Diphenyl Ethers (PentaBDE) Hexabrominated Diphenyl Ethers (HexaBDE) Heptabrominated Diphenyl Ethers (HeptaBDE) Octabrominated Diphenyl Ethers (OctaBDE) Nonabrominated Diphenyl Ethers (NonaBDE) Decabrominated Diphenyl Ether (DecaBDE) Result Remark: mg/kg = Milligram Per Kilogram = ppm = Not Detected Page 2 Of 7
28 WUXH (B)RoHS Requirement: Restricted Substances Limits Cadmium (Cd) 0.01% (100 mg/kg) Lead (Pb) Mercury (Hg) Chromium (VI) (Cr 6+ ) Polybrominated Biphenyls (PBBs) Polybrominated Diphenyl Ethers (PBDEs) The Above Limits Were Quoted From 2002/95/EC And Amendment 2005/618/EC For Homogeneous Material. (C) Test Method: Testing Item Testing Method Reporting Limit Cadmium (Cd)Content Lead (Pb)Content Mercury (Hg)Content Chromium (VI) (Cr 6+ ) Content (For Non-Metal) Polybrominated Biphenyls (PBBs)& Polybrominated Diphenyl Ethers (PBDEs) Date Sample Received: Jul 20, 2012 Testing Period: Jul 20, 2012 To Jul 27,2012 With Reference To IEC Edition 1.0: 2008, By Acid Digestion And Determined By ICP-OES With Reference To IEC Edition 1.0: 2008, By Acid Digestion And Determined By ICP-OES With Reference To IEC Edition 1.0: 2008, By Acid Digestion And Determined By ICP-OES With Reference To IEC Edition 1.0: 2008, By Alkaline Digestion And Determined By UV-VIS Spectrophotometer With Reference To IEC Edition 1.0: 2008, By Solvent Extraction And Determined By GC-MSD And Further HPLC Confirmation When Necessary. 2 mg/kg 2 mg/kg 2 mg/kg 1 mg/kg 5 mg/kg Page 3 Of 7
29 WUXH (D) Measurement Flowchart: Reference Standard: IEC Edition 1.0: 2008 Sampling/Grinding Or Cutting Cd/Pb/Hg Cr 6+ Polymers / Electronics PBBs/PBDEs For Different Material, Digest The Sample With Appropriate Acid *1 Weigh Sample And Add Alkaline Solution Weigh Sample And Add Organic Solvent Confirm The Tested Samples Are Totally Dissolved Yes No Definite Temp. Extraction Soxhlet Extraction Or Solvent Extraction Make Up With Deionized Water Analyzed By ICP-OES Cool And Filter The Extract Make Up With Deionized Water And Add Diphenyl- Carbazide Solution Concentrate The Extract And Make Up With Organic Solvent Analyzed By GC-MSD Analyzed By UV-VIS Chemist: Inorganic (Ann Luo/Fred Wang/Ally Wan) Organic (Jenny Xu/Cherry Sun) Remarks: *1: List Of Appropriate Acid: Material Acid Added For Digestion Polymers HNO 3, HCL,HF,H 2 O 2, H 3 BO 3 Metals HNO 3, HCL,HF Electronics HNO 3, HCL,H 2 O 2, HBF 4 Page 4 Of 7
30 WUXH Halogen Test (I) Test Result Summary : Halogen Content: Testing Item Result (ppm) Submitted Samples Fluorine (F) Content Chlorine (Cl)Content 89 Bromine (Br) Content Iodine (I) Content Remarks : ppm = Parts Per Million = mg/kg = Not Detected Date Sample Received: Jul 20, 2012 Testing Period: Jul 20, 2012 To Jul 27,2012 (II) Test Method : Testing Item Testing Method With Reference To EN 14582:2007 By Combustion In A Halogen (F,Cl, Br,I) Content Calorimetric Bomb And Determined By Ion Chromatography Remarks : Reporting Limit = Quantitation Limit Of Analyte In Sample Reporting Limit 50 ppm Page 5 Of 7
31 WUXH (III) Measurement Flowchart: Test For Halogen Content Reference Method: EN 14582:2007 Sampling/Grinding Or Cutting Add Absorbent In A Combustion Flask & Place Weighed Sample In Fill The Calorimetric Bomb With Oxygen Ignite Then Leave The Flask At Room Temperature Any Test Specimen In The Olorimetric Bomb? Yes No Transfer The Absorbent Into A Volumetric Flask Make Up With Deionized Water Analyzed By Ion Chromatography Chemist: Fred Wang/ Ally Wan Ally Wan Page 6 Of 7
32 WUXH Photo This report is made solely on the basis of your instructions and/or information and materials supplied by you. It is not intended to be a recommendation for any particular course of action. Intertek does not accept a duty of care or any other responsibility to any person other than the Client in respect of this report and only accepts liability to the Client insofar as is expressly contained in the terms and conditions governing Intertek's provision of services to you. Intertek makes no warranties or representations either express or implied with respect to this report save as provided for in those terms and conditions. We have aimed to conduct the Review on a diligent and careful basis and we do not accept any liability to you for any loss arising out of or in connection with this report, in contract, tort, by statute or otherwise, except in the event of our gross negligence or wilful misconduct. Page 7 Of 7
33 WUXH Applicant : SUZHOU GOODARK ELECTRONICS CO., LTD. Date : Jul 26, 2012 NO.31 TONGXI ROAD, TONGAN ECONOMIC DEVELOPMENT ZONE, SUZHOU, P.R.CHINA Attn : MIAO XIAOQING Sample Description As Declared: One (1) Piece Of Submitted Sample Said To Be : Silvery Grey Metal. Sample Item : Tin Ingot. Material Spec : 99.9% Sn. Tests Conducted: As Requested By The Applicant, For Details Refer To Attached Pages Summary: Tested Sample Standard Result Submitted Sample With Reference To Test Method Of IEC Edition 1.0: 2008 And Maximum Concentration Limits Quoted From RoHS Directives 2002/95/EC And Amendment 2005/618/EC Pass Prepared And Checked By: For Jessica Lu General Manager Page 1 Of 5
34 WUXH RoHS Directives Test (A) Test Result Summary: Testing Item Result Cadmium (Cd) Content (mg/kg) Lead (Pb) Content (mg/kg) 230 Mercury (Hg) Content (mg/kg) Chromium (VI)(Cr 6+ ) Result (By Boiling Water Extraction On Metal) (mg/kg With 50cm 2 ) N Polybrominated Biphenyls (PBBs)(mg/kg) Monobrominated Biphenyls (MonoBB) Dibrominated Biphenyls (DiBB) Tribrominated Biphenyls (TriBB) Tetrabrominated Biphenyls (TetraBB) Pentabrominated Biphenyls (PentaBB) Hexabrominated Biphenyls (HexaBB) Heptabrominated Biphenyls (HeptaBB) Octabrominated Biphenyls (OctaBB) Nonabrominated Biphenyls (NonaBB) Decabrominated Biphenyl (DecaBB) Polybrominated Diphenyl Ethers (PBDEs)(mg/kg) Monobrominated Diphenyl Ethers (MonoBDE) Dibrominated Diphenyl Ethers (DiBDE) Tribrominated Diphenyl Ethers (TriBDE) Tetrabrominated Diphenyl Ethers (TetraBDE) Pentabrominated Diphenyl Ethers (PentaBDE) Hexabrominated Diphenyl Ethers (HexaBDE) Heptabrominated Diphenyl Ethers (HeptaBDE) Octabrominated Diphenyl Ethers (OctaBDE) Nonabrominated Diphenyl Ethers (NonaBDE) Decabrominated Diphenyl Ether (DecaBDE) Remark: mg/kg = Milligram Per Kilogram = ppm mg/kg With 50cm 2 = Milligram Per Kilogram With 50 Square Centimeter = Not Detected N=Negative Page 2 Of 5
35 WUXH (B)RoHS Requirement: Restricted Substances Limits Cadmium (Cd) 0.01% (100 mg/kg) Lead (Pb) Mercury (Hg) Chromium (VI) (Cr 6+ ) Polybrominated Biphenyls (PBBs) Polybrominated Diphenyl Ethers (PBDEs) The Above Limits Were Quoted From 2002/95/EC And Amendment 2005/618/EC For Homogeneous Material. (C) Test Method: Testing Item Testing Method Reporting Limit Cadmium (Cd)Content Lead (Pb)Content Mercury (Hg)Content Chromium (VI) (Cr 6+ ) Content (For Metal) Polybrominated Biphenyls (PBBs)& Polybrominated Diphenyl Ethers (PBDEs) Date Sample Received: Jul 20, 2012 Testing Period: Jul 20, 2012To Jul 26, 2012 With Reference To IEC Edition 1.0: 2008, By Acid Digestion And Determined By ICP-OES With Reference To IEC Edition 1.0: 2008, By Acid Digestion And Determined By ICP-OES With Reference To IEC Edition 1.0: 2008, By Acid Digestion And Determined By ICP-OES With Reference To IEC Edition 1.0: 2008, By Boiling Water Extraction And Determined By UV-VIS Spectrophotometer With Reference To IEC Edition 1.0: 2008, By Solvent Extraction And Determined By GC-MSD And Further HPLC Confirmation When Necessary. 2 mg/kg 2 mg/kg 2 mg/kg 0.02mg/kg With 50cm 2 (In Testing Solution) 5 mg/kg Page 3 Of 5
36 WUXH (D) Measurement Flowchart: Reference Standard: IEC Edition 1.0: 2008 Sampling/Grinding Or Cutting Cd/Pb/Hg Cr 6+ PBBs/PBDEs For Different Material, Digest The Sample With Appropriate Acid *1 Metal Get 50cm 2 Samples Weigh Sample And Add Organic Solvent Confirm The Tested Samples Are Totally Dissolved Yes No Boiling Water Extraction Soxhlet Extraction Or Solvent Extraction Make Up With Deionized Water Analyzed By ICP-OES Make Up With Deionized Water And Add Diphenyl- Carbazide Solution Concentrate The Extract And Make Up With Organic Solvent Analyzed By UV-VIS Analyzed By GC-MSD Chemist: Inorganic (Ann Luo/Fred Wang/Ally Wan) Organic (Jenny Xu/Cherry Sun) Remarks: *1: List Of Appropriate Acid: Material Acid Added For Digestion Polymers HNO 3, HCL,HF,H 2 O 2, H 3 BO 3 Metals HNO 3, HCL,HF Electronics HNO 3, HCL,H 2 O 2, HBF 4 Page 4 Of 5
37 WUXH Photo This report is made solely on the basis of your instructions and/or information and materials supplied by you. It is not intended to be a recommendation for any particular course of action. Intertek does not accept a duty of care or any other responsibility to any person other than the Client in respect of this report and only accepts liability to the Client insofar as is expressly contained in the terms and conditions governing Intertek's provision of services to you. Intertek makes no warranties or representations either express or implied with respect to this report save as provided for in those terms and conditions. We have aimed to conduct the Review on a diligent and careful basis and we do not accept any liability to you for any loss arising out of or in connection with this report, in contract, tort, by statute or otherwise, except in the event of our gross negligence or wilful misconduct. Page 5 Of 5
ICP Test Report Certification Packet
ICP Test Report Certification Packet Company name: Suzhou Good-Ark Electronics Co.,Ltd. Product Series: Plastic Minimelf Series Product #: Plastic Minimelf Diode Issue Date: Sep 14, 2012 It is hereby certified
More informationICP Test Report Certification Packet
ICP Test Report Certification Packet Company name : Littelfuse, Inc. Product Series: SMBJ, P6SMB, SACB, 3T, 1KSMB, HTVSB7.0CA-100 Series Product #: TVS Diode Issue Date: August 27, 2013 It is hereby certified
More informationICP Test Report Certification Packet
ICP Test Report Certification Packet Company name : Littelfuse, Inc. Product Series: SMBJ, P6SMB, SACB, 3T, 1KSMB, HTVSB7.0CA-100 Series Product #: TVS Diode Issue Date: August 2, 2014 It is hereby certified
More informationTest Report. As per applicant s request
Applicant: Sigma Ink Corporation Date : Nov 19, 2014 674 Via De La Valle Ste 100, Solana Beach, CA 92075 USA Sample Description: One (1) group of submitted samples said to be : Sample Description : UV
More informationICP Test Report Certification Packet
ICP Test Report Certification Packet Company name : Littelfuse, Inc. Product Series: Mini PCB Holder 153 series Product #: 01530008Z_01530007Z Issue Date: November 12, 2012 It is hereby certified by Littelfuse,
More informationICP Test Report Certification Packet
ICP Test Report Certification Packet Company name : Littelfuse, Inc. Product Series: Omni Block Fuseholder Product #: 520 OMNI Block series Issue Date: April 14, 2014 It is hereby certified by Littelfuse,
More informationICP Test Report Certification Packet
ICP Test Report Certification Packet Company name : Littelfuse, Inc. Product Series: ATOF Product #: 287xxx Series Issue Date: October 23, 2013 It is hereby certified by Littelfuse, Inc. that there is
More informationICP Test Report Certification Packet
ICP Test Report Certification Packet Company name : Littelfuse, Inc. Product Series: Varistors Product #: VxxZXxxP Series Issue Date: May 18, 2010 It is hereby certified by Littelfuse, Inc. that there
More informationCertificate of non-use of The Controlled Substances
Certificate of non-use of The Controlled Substances Company name Product Covered Littelfuse, Inc Thyristor TO-220 L Package (Isolated) Thyristor TO-220 R Package (Non-isolated) Thyristor TO-263 N Package
More informationICP Test Report Certification Packet
ICP Test Report Certification Packet Company name : Littelfuse, Inc. Product Series: TR5 Product #: 370xxxxx Series Issue Date: November 12, 2013 It is hereby certified by Littelfuse, Inc. that there is
More informationICP Test Report Certification Packet
Company Name: Littelfuse, Inc. ICP Test Report Certification Packet Product Type: Surface Mount Varistors Product Series: CH Series RoHS Compliant Models Issue Date: June 4, 2010 It is hereby certified
More informationTEST REPORT NUMBER: SHAH S1 APPLICANT: LITEON SEMICONDUCTOR CORP. 28-1, WU SHIN STREET, TA WU LUNG, KEELUNG 204, TAIWAN, R.O.
APPLICANT: LITEON SEMICOUCTOR CORP. 28-1, WU SHIN STREET, TA WU LUNG, KEELUNG 204, TAIWAN, R.O.C DATE: AUG 20, 2008 SHANGHAI SEEFULL ELECTRONIC CO.,LTD. 6 ZHENGYE RD., DONGJING, SONGJIANG DISTRICT, SHANGHAI,
More informationTEST REPORT NUMBER: SHAH DATE: AUG 18, 2008 APPLICANT: LITEON SEMICONDUCTOR CORP. 28-1, WU SHIN STREET, TA WU LUNG, KEELUNG 204, TAIWAN, R.O.
APPLICANT: LITEON SEMICOUCTOR CORP. 28-1, WU SHIN STREET, TA WU LUNG, KEELUNG 204, TAIWAN, R.O.C DATE: AUG 18, 2008 SHANGHAI SEEFULL ELECTRONIC CO.,LTD. 6 ZHENGYE RD., DONGJING, SONGJIANG DISTRICT, SHANGHAI,
More informationTEST REPORT NUMBER: SHAH S1 APPLICANT: LITEON SEMICONDUCTOR CORP. 28-1, WU SHIN STREET, TA WU LUNG, KEELUNG 204, TAIWAN, R.O.
APPLICANT: LITEON SEMICOUCTOR CORP. 28-1, WU SHIN STREET, TA WU LUNG, KEELUNG 204, TAIWAN, R.O.C DATE: AUG 20, 2008 SHANGHAI SEEFULL ELECTRONIC CO.,LTD. 6 ZHENGYE RD., DONGJING, SONGJIANG DISTRICT, SHANGHAI,
More informationICP Test Report Certification Packet
ICP Test Report Certification Packet Company name : Littelfuse, Inc. Product Series: 3AG Holder Product #: 340 Series Issue Date: November 8, 2012 It is hereby certified by Littelfuse, Inc. that there
More informationIntertek Testing Services Ltd., Shanghai TFH Division Block B, Jinling Business Square,No.801 Yi Shan Road, Shanghai, China, 200233 Tel: +86 21 6120 6565 Fax: +86 21 6127 9740 E-mail: labtest.shanghai@intertek.com
More informationICP Test Report Certification Packet
ICP Test Report Certification Packet Company name : Littelfuse, Inc. Product Series: ATOF Product #: 287xxx Series Issue Date: February 25, 2013 It is hereby certified by Littelfuse, Inc. that there is
More informationCertificate of non-use of The Controlled Substances
Certificate of non-use of The Controlled Substances Company name Product Covered Littelfuse, Inc. SIDACtor, DO-214AA & COMPAK Package SIDAC, DO-214AA Package SiBOD TM, DO-214AA Package, SMTBJ series Thyristor,
More informationICP Test Report Certification Packet
ICP Test Report Certification Packet Company name : Littelfuse, Inc. Product Series: TE5 Product #: 395xxxxxxx Series Issue Date: June 15, 2013 It is hereby certified by Littelfuse, Inc. that there is
More informationMATERIAL DECLARATION & RoHS REPORT
MATERIAL DECLARATION & RoHS REPORT Product Part Number 2038-XX-SMLF Product Line Gas Discharge Tube MSL 1 RoHS Compliant Yes Compliance Date May-2015 No. Construction Element (subpart) 1 Lateral Electrodes
More informationTest Report Number: SHAH Applicant: TE CONNECTIVITY Date: 22 Feb, 2017 BUILDING A5,NO.1528 GUMEI ROAD, SHANGHAI,CHINA Attn: CC WU
Applicant: TE CONNECTIVITY Date: 22 Feb, 2017 BUILDING A5,NO.1528 GUMEI ROAD, SHANGHAI,CHINA Attn: CC WU Sample Description: Three( 3 ) groups of submitted sample said to be : A.White plastic(171370-3)
More informationCertificate of non-use of The Controlled Substances
Certificate of non-use of The Controlled Substances Company name Littelfuse, Inc. Product Covered SIDACtor, QFN Package PLED, QFN Package Issue Date May 04, 2013 It is hereby certified by Littelfuse, Inc.,
More informationTest Report. Applicant : RECOM Engineering GmbH & Co. KG. Date : Jun 03, 2016
Applicant : RECOM Engineering GmbH & Co. KG. Date : Jun 03, 2016 Münzfeld 35 4810 Gmunden AUSTRIA This is to supersede Report No. TWNC00519736 Dated May 16, 2016 Sample Description : One (1) group of submitted
More informationICP Test Report Certification Packet
ICP Test Report Certification Packet Company name : Littelfuse, Inc. Product Series: Pico Product #: 473xxxL Series Issue Date: February 16, 2011 It is hereby certified by Littelfuse, Inc. that there is
More informationICP Test Report Certification Packet
ICP Test Report Certification Packet Company name : Littelfuse, Inc. Product Series: PTC Device Product #: RLD Series 16R, 30R, 60R, 72R, 250R, 600R Issue Date: March 26, 2012 It is hereby certified by
More informationTEST REPORT NUMBER: SHAH TESTS CONDUCTED. (A) TEST RESULT SUMMARY FOR RoHS DIRECTIVE:
TESTS COUCTED (A) TEST RESULT SUMMARY FOR RoHS DIRECTIVE: TESTING ITEM RESULT (ppm) (1) CADMIUM (Cd) CONTENT (ppm) (
More informationICP Test Report Certification Packet
ICP Test Report Certification Packet Company name : Littelfuse, Inc. Product Series: TR5 Product #: 372xxxxx Series Issue Date: June 15, 2013 It is hereby certified by Littelfuse, Inc. that there is neither
More informationICP Test Report Certification Packet
ICP Test Report Certification Packet Company name : Littelfuse, Inc. Product Series: 3.6 x 10 mm Fuse Product #: 875xxx Series Issue Date: April 21, 2014 It is hereby certified by Littelfuse, Inc. that
More informationTEST REPORT. Page : 1 of 9 Report No. RT14R-U E Date: Oct. 13, : The following submitted sample(s) said to be:-
Applicant Address : PSMC Co., Ltd. : #52, Banyeo-1dong, Haeundae-gu, Busan, Korea Page : 1 of 9 Sample Description : The following submitted sample(s) said to be:- Name/Type of Product Name of Material
More informationTEST REPORT. : The following submitted sample(s) said to be:-
Applicant : Amkor Technology Korea, Inc. Address : 280-8, 2-ga, Seongsu-dong, Seongdong-gu, Seoul, 133-706 Korea Page: 1 of 7 Sample Description : The following submitted sample(s) said to be:- Name/Type
More information: DAM1-125,DAM1-160,DAM1-400,DAM1-630,DAM1-800, DAM1-1600
Applicant: Shanghai DADA Electric CO.,Ltd. Date: Aug 10, 2015 No 171,Yezhuang Road, Zhuanghang, Fengxian, Shanghai, China Sample Description: One (1) piece of submitted sample said to be Item Name : Moulded
More informationICP Test Report Certification Packet
ICP Test Report Certification Packet Company name : Littelfuse, Inc. Product Series: 327 series (Micro2 Fuses) Product #: 327 series (Micro2 Fuses) Issue Date: December 8, 2011 It is hereby certified by
More informationICP Test Report Certification Packet
ICP Test Report Certification Packet Company name : Littelfuse, Inc. Product Series: Low Profile Minifuse Product #: 891xxx Series Issue Date: July 27, 2011 It is hereby certified by Littelfuse, Inc. that
More informationTEST REPORT Reference No. : TRHZ Date : Sep. 18, 2013 Page No. : 1 of 5
Reference No. : TRHZ1309618 Date : Sep. 18, 2013 Page No. : 1 of 5 Client : Address : TEFLEX GASKET CO., LTD. CIE INDUSTRIAL ZONE, CIXI CITY, ZHEJIANG, CHINA. The following merchandise was (were) submitted
More informationICP Test Report Certification Packet
ICP Test Report Certification Packet Company name : Littelfuse, Inc. Product Series: TR5 Product #: 373xxxxxxx Issue Date: February 8, 2013 It is hereby certified by Littelfuse, Inc. that there is neither
More informationICP Test Report Certification Packet
ICP Test Report Certification Packet Company name : Littelfuse, Inc. Product Series: Low Profile Minifuse Product #: 891xxx Series Issue Date: August 15, 2012 It is hereby certified by Littelfuse, Inc.
More informationICP Test Report Certification Packet
ICP Test Report Certification Packet Company name : Littelfuse, Inc. Product Series: ATO Product #: 257xxx Series Issue Date: July 25, 2012 It is hereby certified by Littelfuse, Inc. that there is neither
More informationICP Test Report Certification Packet
ICP Test Report Certification Packet Company name : Littelfuse, Inc. Product Series: ATOF Product #: 287xxx Series Issue Date: November 14, 2012 It is hereby certified by Littelfuse, Inc. that there is
More informationApplicant: Cactus Technologies Ltd Date : Apr 07, 2010 Suite C 15/F Capital Trade Center 62 Tsun Yip Street Kwun Tong Kowloon Hong Kong
RoHS Screening Analysis Report Number : TWNC00152904 Applicant: Cactus Technologies Ltd Date : Apr 07, 2010 Suite C 15/F Capital Trade Center 62 Tsun Yip Street Kwun Tong Kowloon Hong Kong Sample Description:
More informationICP Test Report Certification Packet
ICP Test Report Certification Packet Company name : Littelfuse, Inc. Product Series: HR600V 30A series Product #: LFH60030xxxx Issue Date: August 28, 2012 It is hereby certified by Littelfuse, Inc. that
More informationTEST REPORT. : Lead Frame / Ag is plated on Ni-Fe Alloy-A42 material
APPLICANT : PSMC CO., LTD. ADDRESS : 16, Barangongdan-ro 4-gil, Hyangnam-eup, Hwaseong-si, Gyeonggi-do, Korea PAGE: 1 of 10 SAMPLE DESCRIPTION : The following submitted sample(s) said to be:- NAME/TYPE
More informationTEST REPORT. : The following submitted sample(s) said to be:- SAMPLE RECEIVED : Jan. 07, 2019 TESTING DATE : Jan. 07, 2019 ~ Jan.
APPLICANT : KOSTIC KOREA LTD. ADDRESS : 185, Pungmu-ro, Gimpo-si, Gyeonggi-do, Korea PAGE: 1 of 8 SAMPLE DESCRIPTION : The following submitted sample(s) said to be:- NAME/TYPE OF PRODUCT SAMPLE ID NO.
More informationAPPLICANT: CACTUS TECHNOLOGIES LTD DATE : JUL 25, 2007 SUITE /F BILLION TRADE CENTER 31 HUNG TO ROAD KWUN TONG KOWLOON HONG KONG
XRF SCREENING AND CHEMICAL CONFIRMATION REPORT NUMBER : APPLICANT: CACTUS TECHNOLOGIES LTD DATE : JUL 25, 2007 SUITE 2002 20/F BILLION TRADE CENTER 31 HUNG TO ROAD KWUN TONG KOWLOON HONG KONG SAMPLE DESCRIPTION:
More informationTEST REPORT. Address : , Doksan-dong, Geumcheon-gu, Seoul, Korea Page: 1 of 12 Report No. RT16R-S E Date: Jul.
Applicant : Young Yiel Precision Address : 1001-10, Doksan-dong, Geumcheon-gu, Seoul, Korea Page: 1 of 12 : The following submitted sample(s) said to be:- Name/Type of Product Name of Material Item No.
More informationICP Test Report Certification Packet
ICP Test Report Certification Packet Company name : Littelfuse, Inc. Product Series: 3AB Cartridge Product #: 322xxxP Series Issue Date: January 4, 2014 It is hereby certified by Littelfuse, Inc. that
More informationICP Test Report Certification Packet
ICP Test Report Certification Packet Company name : Littelfuse, Inc. Product Series: PulseGuard ESD Protector Product #: PGB1010402KR Series Issue Date: July 26, 2013 It is hereby certified by Littelfuse,
More informationICP Test Report Certification Packet
ICP Test Report Certification Packet Company name : Littelfuse, Inc. Product Series: Sate T-Plus Fuse Product #: 259xxx Series Issue Date: September 5, 2011 It is hereby certified by Littelfuse, Inc. that
More informationICP Test Report Certification Packet
ICP Test Report Certification Packet Company name : Littelfuse, Inc. Product Series: DO214 AB - SMCJ, SMDJ, 1.5SMC,3.0SMC, 5.0SMDJ Series Product #: TVS Diode Issue Date: May 23, 2013 It is hereby certified
More informationTEST REPORT. ADDRESS : 77, Seokam-ro 13-gil, Iksan, Jeonllabuk-do, Korea PAGE: 1 of 8 REPORT NO. RT17R-U2181-E DATE: Dec. 29, 2017
APPLICANT : CALIX ELECTRONIC CHEMICAL CO., LTD. ADDRESS : 77, Seokam-ro 13-gil, Iksan, Jeonllabuk-do, Korea PAGE: 1 of 8 SAMPLE DESCRIPTION : The following submitted sample(s) said to be:- NAME/TYPE OF
More informationICP Test Report Certification Packet
ICP Test Report Certification Packet Company name : Littelfuse, Inc. Product Series: Pico Product #: 473xxxHF Series Issue Date: May 23, 2011 It is hereby certified by Littelfuse, Inc. that there is neither
More informationTEST REPORT : SR A-DC, SR A-DA, SR A-DT, SR A-DN, SR C-DC, SR C-DA, SR C-DT, SR C-DN
Applicant : UTIS Address : 652-10, Choji-dong, Danwon-ku, Ansan-city, Gyeonggi-do, Korea Page: 1 of 5 Sample Description : The following submitted sample(s) said to be:- Name/Type of Product Sample ID
More informationICP Test Report Certification Packet
ICP Test Report Certification Packet Company name : Littelfuse, Inc. Product Series: Compact 3.6 x 10 mm Single Pigtail Fuse Product #: 877xxx Series Issue Date: February 5, 2013 It is hereby certified
More informationTEST REPORT. * Note 2 : This report shall not be reproduced except in full without the written approval of the testing laboratory.
Applicant : Doosan Corporation Electro-Materials Address : 40, Doosan-ro, Jeungpyeong-eup, Jeungpyeong-gun, Chungcheongbuk-do, Korea Page: 1 of 5 : The following submitted sample(s) said to be:- Name/Type
More informationTest Report. LEDELS LIGHTING CO., LTD Address. Applicant
Test Report No. R011412010R-1 Date Dec. 09, 2014 Page 1 of 10 Applicant LEDELS LIGHTING CO., LTD Address 5F, Block C, Mingjinhai Ind. Park, Zhoushi Road, Shiyan, Bao an, Shenzhen, Guangdong, China The
More informationTest Report No. : KA/2012/40043 Date : 2012/04/10 Page : 2 of 8 Test Result(s) PART NAME NO.1 : BLACK EPOXY MOLDING COMPOUNDS Test Item (s): MDL Resul
Test Report No. : KA/2012/40043 Date : 2012/04/10 Page : 1 of 8 The following sample(s) was/were submitted and identified by/on behalf of the client as : Sample Description : Style/Item No. : JP Reference
More informationICP Test Report Certification Packet
ICP Test Report Certification Packet Company name : Littelfuse, Inc. Product Series: 3AB Fuse Product #: 0314030.M52LP Issue Date: September 11, 2014 It is hereby certified by Littelfuse, Inc. that there
More informationTEST REPORT. * Note 2 : This report shall not be reproduced except in full without the written approval of the testing laboratory.
APPLICANT : PILKOR Electronics Division. (of COWELL Fashion Co., Ltd.) ADDRESS : 270, Sinwon-ro(Woncheon-dong), Yeongtong-gu, Suwon-si, Gyeonggi-do, Korea PAGE: 1 of 5 SAMPLE DESCRIPTION : The following
More informationCertificate of non-use of The Controlled Substances
Certificate of non-use of The Controlled Substances Company name Littelfuse, Inc. Product Covered SIDACtor, QFN Package PLED, QFN Package Issue Date February 8, 2014 It is hereby certified by Littelfuse,
More informationPage 2 of 8 Test Result(s) PART NAME No.1 SILVER COLORED PASTE Cadmium (Cd) Lead (Pb) Mercury (Hg) Test Item(s) Hexavalent Chromium Cr(VI) Sum of PBBs
Page 1 of 8 The following samples was/were submitted and identified by/on behalf of the applicant as Sample Submitted By Sample Description Style/Item No. Sample Receiving Date Testing Period DIE BONDING
More informationTest Report. Report No. SCL03H Page 1 of 7
Report No. SCL03H004659 Page 1 of 7 Applicant FOSHAN BLUEROCKET ELECTRONICS CO.,LTD Address NO.45 GUXIN ROAD, CHANCHENG DISTRICT, FOSHAN, GUANGDONG, P.R.C. The following sample(s) and sample information
More informationTest Report No. : KA/2012/61391 Date : 2012/06/28 Page : 2 of 9 Test Result(s) PART NAME NO.1 : BLACK EPOXY MOLDING COMPOUND Test Item (s): Unit Metho
Test Report No. : KA/2012/61391 Date : 2012/06/28 Page : 1 of 9 The following sample(s) was/were submitted and identified by/on behalf of the client as : Sample Description : Style/Item No. : Sample Receiving
More informationVerification Report. No. CANEC Date: 12 Apr Page 1 of 9.
Verification Report. No. CANEC1302893701 Date: 12 Apr 2013. Page 1 of 9. PROMOVER INDUSTRIAL COMPANY LIMITED. N0.34 CHIA SHINE ROAD WAN LUAN VILLAGE PING TUNG COUNTRY 92343 TAIWAN. Sample Name :. SGS Job
More informationTEST REPORT. NO.: A001R Date: Dec 27, 2013 Page 1 of 13
NO.: A001R131220047001 Date: Dec 27, 2013 Page 1 of 13 Applicant: Jinyun Lanxin Electronic Technology Co., Ltd. Address: NO.2XINMIN ROAD,DONGSHAN INDUSTRIAL AREA WUYUN TOWN JINYUN CONUNTY,LISHUI CITY,ZHEJIANG,CHINA
More informationICP Test Report Certification Packet
ICP Test Report Certification Packet Company name : Littelfuse, Inc. Product Series: Inrush Protector Product #: 399xxxxxxx Series Issue Date: Spetember 5, 2011 It is hereby certified by Littelfuse, Inc.
More informationThin Film on Silicon Resistor Networks Models 2NBS, 2QSP Mold Material Change
Bourns Manufacturers Representatives Corporate Distributor Product Managers Americas Sales Team Asia Sales Team Europe Sales Team Bourns Internal Bourns Plant Managers June, 2010 RESISTOR NETWORKS Thin
More informationICP Test Report Certification Packet
ICP Test Report Certification Packet Company name : Littelfuse, Inc. Product Series: ATOF Product #: 287xxx Series Issue Date: August 7, 2012 It is hereby certified by Littelfuse, Inc. that there is neither
More informationTest Report No. SH /CHEM Date: Oct. 22, 2009 Page 1 of 5
Test Report No. SH9202593/CHEM Date: Oct. 22, 2009 Page 1 of 5 ROGERS CORPORATION 245 WOODSTOCK RD. WOODSTOCK, CT 06281 The following sample(s) was/were submitted and identified by/on behalf of the client
More informationTest Report No. CANEC Date: 01 Sep 2011 Page 1 of 8
Test Report No. CANEC1103340401 Date: 01 Sep 2011 Page 1 of 8 GEJIU ZILI MINING&SMEL TING CO.,LTD HUOGUDU,JIJIE TOWN,GEJIU CITY,HONGHE ZHOU,YUNNAN PROVINCE CHINA The following sample(s) was/were submitted
More informationTest Report No. : CE/2008/38467 Date : 2008/04/07 Page : 2 of 11 Test Result(s) PART NAME NO.1 : BLACK PLASTIC TUBE Cadmium (Cd) Lead (Pb) Mercury (Hg
Test Report No. : CE/2008/38467 Date : 2008/04/07 Page : 1 of 11 The following sample(s) was/were submitted and identified by/on behalf of the client as : Sample Description : Style/Item No. : Lot No.
More informationTest Report No. : KE/2016/B2076 Date : 2016/11/24 Page : 2 of 8 Test Result(s) PART NAME NO.1 : GRAY Test Item (s): Unit Method Cadmium (Cd) mg/kg Wit
Test Report No. : KE/2016/B2076 Date : 2016/11/24 Page : 1 of 8 The following sample(s) was/were submitted and identified by/on behalf of the client as : Sample Description : Lot No. : Material Component
More informationTest Report No. : CE/2009/45866B Date : 2009/05/20 Page : 1 of 7
Test Report No. : CE/2009/45866B Date : 2009/05/20 Page : 1 of 7 The following sample(s) was/were submitted and identified by/on behalf of the client as : Sample Description : Style/Item No. : Sample Receiving
More informationVerification Report. No. CANEC Date: 10 Jul Page 1 of 13.
Verification Report. No. Date: 10 Jul 2012. Page 1 of 13. 10GTEK TRANSCEIVERS CO.,LTD. 7 FLOOR WEST, ANLE WUYE BUILDING, SHUNFENG ROAD, AREA 44, BAOAN DISTRICT, SHENZHEN, GUANGDONG PROVINCE, CHINA. Sample
More informationTEST REPORT. * Note 2 : This report shall not be reproduced except in full without the written approval of the testing laboratory.
APPLICANT : KOSTIC KOREA LTD. ADDRESS : 120, LG-ro 360beon-gil, Wollong-myeon, Paju-si, Gyeonggi-do, Korea PAGE: 1 of 10 SAMPLE DESCRIPTION : The following submitted sample(s) said to be:- NAME/TYPE OF
More informationTest Report No. : KA/2012/41514 Date : 2012/05/07 Page : 2 of 9 Test Result(s) PART NAME NO.1 : SILVER NIPPON COPPER WIRE Cadmium (Cd) mg/kg With refe
Test Report No. : KA/2012/41514 Date : 2012/05/07 Page : 1 of 9 The following sample(s) was/were submitted and identified by/on behalf of the client as : Sample Description : Style/Item No. : JP Reference
More informationNo. CE/2014/51910 Date 2014/05/20 Page 2 of 5 Test Result(s) PART NAME No.1 Cadmium (Cd) Lead (Pb) Mercury (Hg) Test Item(s) Hexavalent Chromium Cr(VI
No. CE/2014/51910 Date 2014/05/20 Page 1 of 5 The following sample(s) was/were submitted and identified by/on behalf of the applicant as Sample Submitted By Sample Description Buyer/Order No. Other Info.
More informationVerification Result :.
Verification Report. No. SZXEC1700532001 Date: 13 Jun 2017. Page 1 of 15. SHENZHEN REFLYING ELECTRONIC CO.,LTD. 6 BLDG, GAOXINJIAN INDUSTRIAL ZONE, HEPING VILLAGE,FUYONG TOWN,BAO AN DISTRICT,SHENZHEN,
More informationNo. KE/2016/52417 Date 2016/05/26 Page 2 of 6 Test Result(s) PART NAME No.1 Test Item(s) Cadmium (Cd) Lead (Pb) Mercury (Hg) Hexavalent Chromium Cr(VI
No. KE/2016/52417 Date 2016/05/26 Page 1 of 6 The following sample(s) was/were submitted and identified by/on behalf of the client as Sample Description Style/Item No. Material Component Color Sample Receiving
More informationNo. : CE/2012/A3090 Date : 2012/10/23 GAP PAD 1000SF RICK STEWART REPORT PER REQUEST FOR QUOTE, DATED 10/5/11
No. CE/2012/A3090 Date 2012/10/23 Page 1 of 5 The following sample(s) was/were submitted and identified by/on behalf of the client as Sample Description Buyer/Order No. Other Info. Sample Receiving Date
More informationICP Test Report Certification Packet
ICP Test Report Certification Packet Company name : Littelfuse, Inc. Product Series: FUSE - FKS Product #: 162.6185.4xxx Series Issue Date: November 17, 2011 It is hereby certified by Littelfuse, Inc.
More informationICP Test Report Certification Packet
ICP Test Report Certification Packet Company name : Littelfuse, Inc. Product Series: Class CC Fuse TD 600 VAC Product #: KLDR Series (except 20A & 8-15A) Issue Date: October 25, 2012 It is hereby certified
More informationVerification Result :.
Verification Report. No. CANEC1405274901 Date: 05 May 2014. Page 1 17. AMERICAN POWER CONVERSION HOLDING INC.,TAIWAN BRANCH. 3F.,NO. 205, SEC.3, BEIXIN RD., 231 XINDIAN DIST., NEW TAIPEI CITY, 231 TAIWAN.
More informationChemical Laboratory - Kao., SGS Taiwan Ltd. Test Report No. : KE/2017/40842 Date : 2017/04/17 ROGERS CORPORATION 245 WOODSTOCK ROAD, WOODSTOCK, CT. 06
Page: 1 of 7 The following sample(s) was/were submitted and identified by/on behalf of the client as : Sample Description : Style/Item No. : Color : Sample Receiving Date : Testing Period : Sample Submitted
More informationICP Test Report Certification Packet
Company Name: Littelfuse, Inc. ICP Test Report Certification Packet Product Type: Metal Oxide Varistors Product Series: TMOV/ itmov Series RoHS Compliant Models Issue Date: May 25, 2011 It is hereby certified
More informationPage 2 of 12 Test Result(s) PART NAME No.1 IC TRANSCEIVER Test Item(s) Cadmium (Cd) Unit Method With reference to IEC (2013) and performed by
Page 1 of 12 The following samples was/were submitted and identified by/on behalf of the applicant as Sample Submitted By Sample Description Style/Item No. Buyer/Order No. Other Info. Sample Receiving
More informationTest Report No. KD/2013/50027A-01 Date 2013/07/01 Page 2 of 6 Test Result(s) PART NAME No.1 PART NAME No.2 PART NAME No.3 Cadmium (Cd) Lead (Pb) Mercu
Test Report No. KD/2013/50027A-01 Date 2013/07/01 Page 1 of 6 The following sample(s) was/were submitted and identified by/on behalf of the client as Sample Description Style/Item No. Sample Receiving
More informationThe following sample(s) was/were submitted and identified by/on behalf of the client as : (2) (3) (4) (5) Please refer to next page(s).
Test Report No. : CE/2007/C7382B Date : 2008/06/18 Page : 1 of 5 The following sample(s) was/were submitted and identified by/on behalf of the client as : Sample Description : Style/Item No. : Manufacturer
More informationTest Report. Report No. ECL01I Page 1 of 7
Report No. ECL01I058317 Page 1 of 7 Applicant MITSUI HIGH-TEC (SHANGHAI) CO.,LTD Address NO.2001 XINJIN QIAO ROAD EXPORT PROCESSING ZONE PUDONG SHANGHAI CHINA The following sample(s) and sample information
More informationTest Report No. : CE/2014/B4428 Date : 2014/12/03 Page : 1 of 12 PELNOX CO., LTD. 8-7 BODAI, HADANO CITY, KANAGAWA , JAPAN *CE/2014/B4428* The
Test Report No. : CE/2014/B4428 Date : 2014/12/03 Page : 1 of 12 The following sample(s) was/were submitted and identified by/on behalf of the applicant as : Sample Description Style/Item No. Sample Receiving
More informationTest Report. Report No. RLSHD Page 1 of 6
Report No. RLSHD000756910001 Page 1 of 6 Applicant Address WUJIANG MIGHTYTEK SEMICONDUCTOR CO.,LTD NO.2100 NORTH OF ZHONGSHAN ROAD,SONGLING TOWN,WUJIANG CITY Report on the submitted sample said to be Sample
More informationTest Report. Report No. ECL01H Page 1 of 9
Report No. ECL01H067809001 Page 1 of 9 Applicant Address LITE-ON MICROELECTRONICS (WUXI) CO., LTD. LITE-ON SEMICONDUCTOR CORP. LAND LOT J7 J8WEPZ, NEW DISTRICT, WUXI CITY, JIANGSU, CHINA 9F,NO.233-2 PAO-CHIAO
More informationTest Report. Report No. RLSHE Page 2 of 5 Test Result: Content 1 2
Report No. RLSHE001093670001 Page 1 of 5 Applicant NANTONG HUADA MICROELECTRONICS GROUP CO., LTD Address NO.99 ZILANG ROAD,NANTONG CITY,JIANGSU PROVINCE The following sample(s)and sample information was/were
More informationTest Report NO.: ASZ L-2 Date: Jun 19, 2008 Page 1 of 5
Test Report NO.: ASZ0806043504L-2 Date: Jun 19, 2008 Page 1 of 5 Customer: Foshan ADL lighting Co., Ltd Address: No.1, LIANHE Industrial Zone, Luocun, Nanhai, Foshan, Guangdong, China. Report on the submitted
More informationPage 2 of 12 Test Result(s) PART NAME No.1 DK. BROWN LUMP Cadmium (Cd) Lead (Pb) Mercury (Hg) Antimony (Sb) Beryllium (Be) Test Item(s) Hexavalent Chr
Page 1 of 12 The following samples was/were submitted and identified by/on behalf of the applicant as Sample Submitted By Sample Description Style/Item No. Sample Receiving Date Testing Period ELEKTRISOLA
More informationTest Report No. : KA/2010/C2116 Date : 2011/01/05 Page : 2 of 6 Test results by chemical method (Unit: mg/kg) Cadmium (Cd) Lead (Pb) Mercury (Hg) Hexa
Test Report No. : KA/2010/C2116 Date : 2011/01/05 Page : 1 of 6 The following sample(s) was/were submitted and identified by/on behalf of the client as : Sample Description : Color : Sample Receiving Date
More informationNo. CE/2012/C1503 Date 2012/12/18 Page 2 of 6 Test Result(s) PART NAME No.1 Test Item(s) Cadmium (Cd) Lead (Pb) Mercury (Hg) Hexavalent Chromium Cr(VI
No. CE/2012/C1503 Date 2012/12/18 Page 1 of 6 The following sample(s) was/were submitted and identified by/on behalf of the client as Sample Description Buyer/Order No. Other Info. Sample Receiving Date
More informationPage 2 of 9 Test Result(s) PART NAME No.1 DARK BROWN PASTE Test Item(s) Cadmium (Cd) Lead (Pb) Unit Method With reference to IEC (2013) and pe
Page 1 of 9 The following samples was/were submitted and identified by/on behalf of the applicant as Sample Submitted By Sample Description Style/Item No. Sample Receiving Date Testing Period TSF-6522
More informationTest Report MITSUI HIGH-TEC (SHANGHAI) CO.,LTD NO.2001 XINJIN QIAO ROAD EXPORT PROCESSING ZONE PUDONG SHANGHAI CHINA
Report No. ECL01H033498 Page 1 of 7 Applicant Address MITSUI HIGH-TEC (SHANGHAI) CO.,LTD NO.2001 XINJIN QIAO ROAD EXPORT PROCESSING ZONE PUDONG SHANGHAI CHINA The following sample(s) and sample information
More informationTest Report No. : KA/2012/21431 Date : 2012/02/24 Page : 2 of 12 Test Result(s) PART NAME NO.1 : SILVER GRAY DIE ATTACH PASTE Test Item (s): Unit Meth
Test Report No. : KA/2012/21431 Date : 2012/02/24 Page : 1 of 12 The following sample(s) was/were submitted and identified by/on behalf of the client as : Sample Description : Style/Item No. : Sample Receiving
More information