ICP Test Report Certification Packet
|
|
- Solomon Harrell
- 5 years ago
- Views:
Transcription
1 ICP Test Report Certification Packet Company name : Littelfuse, Inc. Product Series: TE5 Product #: 395xxxxxxx Series Issue Date: June 15, 2013 It is hereby certified by Littelfuse, Inc. that there is neither RoHS (EU Directive 2002/95/E, 2011/65/EU)-restricted substance nor such use, for materials to be used for unit parts, for packing/packaging materials, and for additives and the like in the manufacturing processes. In addition, it is hereby reported to you that the parts and sub-materials, the materials to be used for unit parts, the packing/packaging materials, and the additives and the like in the manufacturing processes, are all composed of the following components. Issued by: <Global EHS Specialist> (1) Parts, sub-materials and unit parts This document covers the TE5 RoHS-Compliant series products manufactured by Littelfuse, Inc. < Raw Materials Used Please see Table 1 (2) The ICP data on all measurable substances Remarks: Please see appropriate pages as identifed in Table 1 1 Form Rev. A 2/21/06
2 Table 1: List of Raw Materials covered by this report Total Parts Raw Material Part Number Raw Material Description Page(s) 1 DRKOxxx Element DRCUxxx Element DRAGxxx Element LOZZ194 (692213) Wire-Solder Cap Socket with pin Ceramic Paper
3 Test Report Number : TWNC Applicant: Littelfuse Philippines Inc. Date : Jan 17, 2013 LIMA Technology Center, Lipa City, Malvar, Batangas Sample Description: One (1) group of submitted samples said to be : Part Description : Copper Nickel Alloy wires Part Number : DRKO Date Sample Received : Jan 11, 2013 Date Test Started : Jan 11, 2013 : As requested by the applicant, for details please refer to attached pages. Authorized by: On Behalf of Intertek Testing Services Taiwan Limited K. Y. Liang Director *THJ * Page 1 of 5 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 11492, Taiwan, R.O.C 台北市內湖區瑞光路 423 號 8 樓
4 Number : TWNC (Ⅰ) Test Result Summary: Result Test Item Unit Test Method Submitted RL samples Heavy Metal Cadmium (Cd) content ppm With reference to IEC 62321: 2008, by microwave digestion and 2 determined by ICP-OES. Lead (Pb) content ppm With reference to IEC 62321: 2008, by microwave digestion and 2 determined by ICP-OES. Mercury (Hg) content ppm With reference to IEC 62321: 2008, by microwave digestion and determined by ICP-OES. 2 With reference to IEC mg/kg 62321: 2008, by boiling Chromium VI (Cr 6+ ) content with water extraction and Negative cm 2 determined by UV-Vis Spectrophotometer. Remarks: ppm = parts per million based on weight of tested sample = mg/kg = Not detected RL = Reporting Limit, Quantitation limit of analyte in sample mg/kg with 50cm 2 = milligram per kilogram with 50 square centimeter Negative = A negative test result indicated positive observation was not found at the time of Test. When the spot test showed a negative result, the boiling water extraction procedure shall be used to verify the result. Responsibility of Chemist: Kevin Liu/ Irene Chiou Date Sample Received : Jan 11, 2013 Test Period : Jan 11, 2013 To Jan 15, 2013 (Ⅱ) RoHS Limits: Restricted Substances Cadmium (Cd) content Lead (Pb) content Mercury (Hg) content Chromium VI (Cr 6+ ) content Limits 0.01% (100ppm) 0.1% (1000ppm) 0.1% (1000ppm) 0.1% (1000ppm) The above limits were quoted from Annex II of 2011/65/EU for homogeneous material. *THJ * Page 2 of 5 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 11492, Taiwan, R.O.C 台北市內湖區瑞光路 423 號 8 樓
5 Number : TWNC (Ⅳ) Measurement Flowchart: Test For Cd/Pb/Hg/Chromium (VI) Reference Standard:IEC edition 1.0:2008 Sampling/grinding or cutting Cd/Pb/Hg Metal Cr 6+ Polymers / Electronics For different material, digest the sample with appropriate acid *1 Confirm the tested samples are totally dissolved By spot test Negative *2 Get 50cm 2 sample Weigh sample and add alkaline solution Definite temp. extraction Make up with deionized water Boiling water extraction Cool and filter the extract Analyzed by ICP-OES Make up with deionized water and add diphenylcarbazide solution Analyzed by UV-VIS *THJ * Page 3 of 5 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 11492, Taiwan, R.O.C 台北市內湖區瑞光路 423 號 8 樓
6 Number : TWNC Remarks: *1: List of Appropriate Acid: Material Acid Added for Digestion Polymers HNO 3, HCl,HF,H 2 O 2, H 3 BO 3 Metals HNO 3, HCl,HF Electronics HNO 3, HCl,H 2 O 2, HBF 4 *2: If the result of spot test is positive, Chromium VI would be determined as detected. End of Report This report is made solely on the basis of your instructions and/or information and materials supplied by you. It is not intended to be a recommendation for any particular course of action. Intertek does not accept a duty of care or any other responsibility to any person other than the Client in respect of this report and only accepts liability to the Client insofar as is expressly contained in the terms and conditions governing Intertek's provision of services to you. Intertek makes no warranties or representations either express or implied with respect to this report save as provided for in those terms and conditions. We have aimed to conduct the Review on a diligent and careful basis and we do not accept any liability to you for any loss arising out of or in connection with this report, in contract, tort, by statute or otherwise, except in the event of our gross negligence or wilful misconduct. *THJ * Page 4 of 5 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 11492, Taiwan, R.O.C 台北市內湖區瑞光路 423 號 8 樓
7 Number : TWNC Photo *THJ * Page 5 of 5 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 11492, Taiwan, R.O.C 台北市內湖區瑞光路 423 號 8 樓
8 Test Report Number : TWNC Applicant: Elschukom Elektroschutzkomponentenbau Date : Jan 30, 2013 GmbH Gewerbestrasse 87, D Veilsdorf, Germany Sample Description: One (1) group of submitted samples said to be : Sample Description :Tin plated Wires Style / Item No. :Please see page two to three. Country of Origin :Germany Date Sample Received :Jan 23, 2013 Date Test Started :Jan 23, 2013 : As requested by the applicant, for details please refer to attached pages. Authorized by: On Behalf of Intertek Testing Services Taiwan Limited K. Y. Liang Director *THJ * Page 1 of 8 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 11492, Taiwan, R.O.C 台北市內湖區瑞光路 423 號 8 樓
9 Test Report Number : TWNC Sample Description: Style / Item No. : (A-1) tin plated copper wire Cu, Sn--% (A-2) tin plated, copper plated copper nickel alloy wire Elcon30, Sn--% (A-3) tin plated, copper plated steel wire ElconF, Sn--% (A-4) tin plated, copper plated iron nickel alloy wire ElconD, Sn--% (A-5) tin plated copper nickel alloy wire - CuNi44, Sn--% (A-6) tin plated, silver plated copper wire Cu, Ag--%, Sn--% (A-7) tin plated brass wire Cu80Zn20, Sn--% Authorized by: On Behalf of Intertek Testing Services Taiwan Limited K. Y. Liang Director *THJ * Page 2 of 8 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 11492, Taiwan, R.O.C 台北市內湖區瑞光路 423 號 8 樓
10 Test Report Number : TWNC Sample Description: Style / Item No. : (A-9) tin plated silver copper alloy wire AgCu90, Sn--% (ElCu90, Sn--%) (A-10) tin plated copper zinc alloy wire Cu70Zn30, Sn--% (A-11) tin plated copper nickel alloy wire CuNi12, Sn--% (A-12) tin plated silver copper alloy wire Ag72Cu28, Sn--% (A-13) tin plated silver wire Ag1000, Sn--% (A-14) tin plated silver copper alloy wire Ag45Cu55, Sn--%(AgCu55, Sn) (A-15) tin plated silver copper alloy wire AgCu70, Sn--%(ElCu70, Sn) (A-16) tin plated silver copper alloy wire AgCu80, Sn--%(Elcu80, Sn) (A-17) tin plated tungsten wire W, Sn Authorized by: On Behalf of Intertek Testing Services Taiwan Limited K. Y. Liang Director *THJ * Page 3 of 8 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 11492, Taiwan, R.O.C 台北市內湖區瑞光路 423 號 8 樓
11 Number : TWNC (Ⅰ) Test Result Summary: Heavy Metal Cadmium (Cd) content Lead (Pb) content Mercury (Hg) content Test Item Unit Test Method Chromium VI (Cr 6+ ) content ppm ppm ppm mg/kg with 50 cm 2 With reference to IEC 62321: 2008, by microwave digestion and determined by ICP-OES. With reference to IEC 62321: 2008, by microwave digestion and determined by ICP-OES. With reference to IEC 62321: 2008, by microwave digestion and determined by ICP-OES. With reference to IEC 62321: 2008, by boiling water extraction and determined by UV-Vis Spectrophotometer. Result Mixed all kinds of metal wire RL Negative (#) 0.02 Remarks: ppm = parts per million based on weight of tested sample = mg/kg = Not detected RL = Reporting Limit, Quantitation limit of analyte in sample mg/kg with 50cm 2 = milligram per kilogram with 50 square centimeter Negative = A negative test result indicated positive observation was not found at the time of Test. When the spot test showed a negative result, the boiling water extraction procedure shall be used to verify the result. # = Due to the insufficient sample area, reduced total sample surface of 10 cm 2 was used and the dilution factor was adjusted accordingly. Responsibility of Chemist: Kevin Liu/ Irene Chiou Date Sample Received : Jan 23, 2013 Test Period : Jan 23, 2013 To Jan 29, 2013 *THJ * Page 4 of 8 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 11492, Taiwan, R.O.C 台北市內湖區瑞光路 423 號 8 樓
12 Number : TWNC (Ⅱ) RoHS Limits: Restricted Substances Cadmium (Cd) content Lead (Pb) content Mercury (Hg) content Chromium VI (Cr 6+ ) content Limits 0.01% (100ppm) 0.1% (1000ppm) 0.1% (1000ppm) 0.1% (1000ppm) The above limits were quoted from Annex II of 2011/65/EU for homogeneous material. *THJ * Page 5 of 8 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 11492, Taiwan, R.O.C 台北市內湖區瑞光路 423 號 8 樓
13 Number : TWNC (Ⅲ) Measurement Flowchart: Test for Cd/Pb/Hg/Chromium (VI) Reference Standard:IEC edition 1.0:2008 Sampling/grinding or cutting Cd/Pb/Hg Metal Cr 6+ Polymers / Electronics For different material, digest the sample with appropriate acid *1 Confirm the tested samples are totally dissolved By spot test Negative *2 Get 50cm 2 sample Weigh sample and add alkaline solution Definite temp. extraction Make up with deionized water Boiling water extraction Cool and filter the extract Analyzed by ICP-OES Make up with deionized water and add diphenylcarbazide solution Analyzed by UV-VIS *THJ * Page 6 of 8 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 11492, Taiwan, R.O.C 台北市內湖區瑞光路 423 號 8 樓
14 Number : TWNC Remarks: *1: List of Appropriate Acid: Material Acid Added for Digestion Polymers HNO 3,HCl,HF,H 2 O 2,H 3 BO 3 Metals HNO 3,HCl,HF Electronics HNO 3,HCl,H 2 O 2,HBF 4 *2: If the result of spot test is positive, Chromium VI would be determined as detected. End of Report This report is made solely on the basis of your instructions and/or information and materials supplied by you. It is not intended to be a recommendation for any particular course of action. Intertek does not accept a duty of care or any other responsibility to any person other than the Client in respect of this report and only accepts liability to the Client insofar as is expressly contained in the terms and conditions governing Intertek's provision of services to you. Intertek makes no warranties or representations either express or implied with respect to this report save as provided for in those terms and conditions. We have aimed to conduct the Review on a diligent and careful basis and we do not accept any liability to you for any loss arising out of or in connection with this report, in contract, tort, by statute or otherwise, except in the event of our gross negligence or wilful misconduct. *THJ * Page 7 of 8 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 11492, Taiwan, R.O.C 台北市內湖區瑞光路 423 號 8 樓
15 Number : TWNC Photo *THJ * Page 8 of 8 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 11492, Taiwan, R.O.C 台北市內湖區瑞光路 423 號 8 樓
16
17
18
19
20
21 Test Report Number : TWNC Applicant: Littelfuse Philippines Inc. Date : Nov 01, 2012 LIMA Technology Center, Lipa City, Malvar, Batangas Sample Description: One (1) group of submitted samples said to be : Part Description : Solder wire Part Number : Date Sample Received : Oct 24, 2012 Date Test Started : Oct 25, 2012 : As requested by the applicant, for details please refer to attached pages. Authorized By: On Behalf Of Intertek Testing Services Taiwan Limited K. Y. Liang Director *THJ * Page 1 of 6 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 114 台北市內湖區瑞光路 423 號 8 樓
22 Number : TWNC (Ⅰ) Test Result Summary : Heavy Metal Test Item Result (ppm) Silvery Metal Wire Cadmium (Cd) content Lead (Pb) content 84 Mercury (Hg) content Chromium VI (Cr 6+ ) content (mg/kg with 50cm 2 ) Negative (< 0.02) Remarks: ppm = Parts per million based on weight of tested sample = mg/kg = Not detected < = Less than mg/kg with 50cm 2 = milligram per kilogram with 50 square centimetre Negative = A negative test result indicated positive observation was not found at the time of Test. Responsibility of Chemist : Irene Chiou / Kevin Liu Date Sample Received : Oct 24, 2012 Test Period : Oct 25, 2012 To Nov 01, 2012 (Ⅱ) RoHS Limits: Restricted Substances Cadmium (Cd) Content Lead (Pb) Content Mercury (Hg) Content Chromium VI (Cr 6+ ) Content Limits 0.01% (100ppm) 0.1% (1000ppm) 0.1% (1000ppm) 0.1% (1000ppm) The above limits were quoted from Annex II of 2011/65/EU for homogeneous material. *THJ * Page 2 of 6 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 114 台北市內湖區瑞光路 423 號 8 樓
23 Number : TWNC (Ⅲ) Test Method: Test Item Test Method Reporting Limit With reference to IEC edition 1.0:2008 in clause 8/9/10, by Cadmium (Cd) microwave digestion until the tested content samples are totally dissolved and 2 ppm determined by ICP-OES. Lead (Pb) content With reference to IEC edition 1.0:2008 in clause 8/9/10, by microwave digestion until the tested samples are totally dissolved and 2 ppm Mercury (Hg) content Chromium VI (Cr 6+ ) content determined by ICP-OES. With reference to IEC edition 1.0:2008 in clause 7, by microwave digestion until the tested samples are totally dissolved and determined by ICP-OES. With reference to IEC edition 1.0:2008 in annex B, by boiling water extraction and determined by UV-Vis Spectrophotometer. Remark: Reporting limit = Quantitation limit of analyte in sample 2 ppm 0.02 mg/kg with 50cm 2 *THJ * Page 3 of 6 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 114 台北市內湖區瑞光路 423 號 8 樓
24 Number : TWNC (Ⅳ) Measurement Flowchart: Test for Cd/Pb/Hg/Chromium (VI) Reference Standard:IEC edition 1.0:2008 Sample preparation Take sample and immerse into Aqua Regia, start to strip plating layer Stop the stripping procedure upon color change completely Take the Aqua solution as plating component and stripped body as substrate component Cd/Pb/Hg Metal Cr 6+ Polymers / electronics For different material, digest the sample with appropriate acid *1 Confirm the tested samples are totally dissolved By spot test Get 50cm 2 sample Negative *2 Weigh sample and add alkaline solution Definite temp. extraction Make up with deionized water By boiling water extraction Cool and filter the extract Analyzed by ICP-OES Make up with deionized water and add diphenyl-carbazide solution Analyzed by UV-VIS *THJ * Page 4 of 6 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 114 台北市內湖區瑞光路 423 號 8 樓
25 Number : TWNC Remarks: *1: List of Appropriate Acid: Material Acid Added for Digestion Polymers HNO 3, HCl,HF,H 2 O 2, H 3 BO 3 Metals HNO 3, HCl,HF Electronics HNO 3, HCl,H 2 O 2, HBF 4 *2: If the result of spot test is positive, Chromium VI would be determined as detected. End of Report This report is made solely on the basis of your instructions and/or information and materials supplied by you. It is not intended to be a recommendation for any particular course of action. Intertek does not accept a duty of care or any other responsibility to any person other than the Client in respect of this report and only accepts liability to the Client insofar as is expressly contained in the terms and conditions governing Intertek's provision of services to you. Intertek makes no warranties or representations either express or implied with respect to this report save as provided for in those terms and conditions. We have aimed to conduct the Review on a diligent and careful basis and we do not accept any liability to you for any loss arising out of or in connection with this report, in contract, tort, by statute or otherwise, except in the event of our gross negligence or wilful misconduct. *THJ * Page 5 of 6 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 114 台北市內湖區瑞光路 423 號 8 樓
26 Number : TWNC Photo *THJ * Page 6 of 6 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 114 台北市內湖區瑞光路 423 號 8 樓
27 Test Report Number : TWNC Applicant: Littelfuse Philippines Inc. Date : Oct 31, 2012 LIMA Technology Center, Lipa City, Malvar, Batangas Sample Description: One (1) group of submitted samples said to be : Part Description : TRTE cap Part Number : Date Sample Received : Oct 24, 2012 Date Test Started : Oct 25, 2012 : As requested by the applicant, for details please refer to attached pages. Authorized By: On Behalf Of Intertek Testing Services Taiwan Limited K. Y. Liang Director *THJ * Page 1 of 9 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 114 台北市內湖區瑞光路 423 號 8 樓
28 (Ⅰ) Test Result Summary : Test Item Heavy Metal Cadmium (Cd) content Lead (Pb) content Mercury (Hg) content Chromium VI (Cr 6+ ) content Polybrominated Biphenyls (PBBs) Monobrominated Biphenyls (MonoBB) Dibrominated Biphenyls (DiBB) Tribrominated Biphenyls (TriBB) Tetrabrominated Biphenyls (TetraBB) Pentabrominated Biphenyls (PentaBB) Hexabrominated Biphenyls (HexaBB) Heptabrominated Biphenyls (HeptaBB) Octabrominated Biphenyls (OctaBB) Nonabrominated Biphenyls (NonaBB) Decabrominated Biphenyl (DecaBB) Polybrominated Diphenyl Ethers (PBDEs) Monobrominated Diphenyl Ethers (MonoBDE) Dibrominated Diphenyl Ethers (DiBDE) Tribrominated Diphenyl Ethers (TriBDE) Tetrabrominated Diphenyl Ethers (TetraBDE) Pentabrominated Diphenyl Ethers (PentaBDE) Hexabrominated Diphenyl Ethers (HexaBDE) Heptabrominated Diphenyl Ethers (HeptaBDE) Octabrominated Diphenyl Ethers (OctaBDE) Nonabrominated Diphenyl Ethers (NonaBDE) Decabrominated Diphenyl Ether (DecaBDE) Halogen Content Fluorine (F) Chlorine (Cl) Bromine (Br) Iodine (I) Number : TWNC Result (ppm) Brown Plastic *THJ * Page 2 of 9 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 114 台北市內湖區瑞光路 423 號 8 樓
29 (Ⅰ) Test Result Summary : Test Item Phthalates Di(2-ethylhexyl) Phthalate (DEHP) Dibutyl Phthalate (DBP) Benzyl Butyl Phthalate (BBP) Others Hexabromocyclododecane (HBCDD) Number : TWNC Result (ppm) Brown Plastic Remarks: ppm = Parts per million based on weight of tested sample = mg/kg = Not detected Responsibility of Chemist : Irene Chiou / Kevin Liu / Cathy Chen Date Sample Received : Oct 24, 2012 Test Period : Oct 25, 2012 To Oct 30, 2012 (Ⅱ) RoHS Limits: Restricted Substances Cadmium (Cd) Content Lead (Pb) Content Mercury (Hg) Content Chromium VI (Cr 6+ ) Content Polybrominated Biphenyls (PBBs) Polybrominated Diphenyl Ehters (PBDEs) Limits 0.01% (100ppm) 0.1% (1000ppm) 0.1% (1000ppm) 0.1% (1000ppm) 0.1% (1000ppm) 0.1% (1000ppm) The above limits were quoted from Annex II of 2011/65/EU for homogeneous material. *THJ * Page 3 of 9 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 114 台北市內湖區瑞光路 423 號 8 樓
30 Number : TWNC (Ⅲ) Test Method: Test Item Test Method Reporting Limit With reference to IEC edition 1.0:2008 in clause 8/9/10, by Cadmium (Cd) content microwave digestion until the tested 2 ppm samples are totally dissolved and determined by ICP-OES. With reference to IEC edition 1.0:2008 in clause 8/9/10, by Lead (Pb) content microwave digestion until the tested 2 ppm samples are totally dissolved and determined by ICP-OES. With reference to IEC edition 1.0:2008 in clause 7, by microwave Mercury (Hg) content digestion until the tested samples 2 ppm are totally dissolved and determined by ICP-OES. With reference to IEC edition Chromium VI (Cr 6+ ) 1.0:2008 in annex C, by alkaline content digestion and determined by UV-Vis 1 ppm spectrophotometer. Polybrominated Biphenyls (PBBs) Polybrominated Diphenyl Ethers (PBDEs) Halogen Content Phthalates Hexabromocyclododecane (HBCDD) With reference to IEC edition 1.0:2008 in annex A, by solvent extraction and determined by GC-MS and further HPLC-DAD confirmation when necessary. With reference to IEC edition 1.0:2008 in annex A, by solvent extraction and determined by GC-MS and further HPLC-DAD confirmation when necessary. With reference to EN 14582:2007 by calorimetric bomb with oxygen and determined by Ion Chromatograph. With reference to EN 14372: 2004, by solvent extraction and determined by GC-MS. With reference to USEPA 3540C, by solvent extraction and determined by GC-MSD. Remark: Reporting limit = Quantitation limit of analyte in sample 5 ppm 5 ppm 50 ppm 50 ppm 10 ppm *THJ * Page 4 of 9 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 114 台北市內湖區瑞光路 423 號 8 樓
31 Number : TWNC (Ⅳ) Measurement Flowchart: Test for Cd/Pb/Hg/Chromium (VI)/PBBS/PBDES Contents Reference Standard: IEC edition 1.0:2008 For metal part Sample preparation For non-metal part Take sample and immerse into Aqua Regia, start to strip plating layer Stop the stripping procedure upon color change completely Take the Aqua solution as plating component and stripped body as substrate component Cd/Pb/Hg Metal Cr 6+ Polymers / electronics PBBs/PBDEs For different material, digest the sample with appropriate acid *1 Confirm the tested samples are totally dissolved By spot test Get 50cm 2 sample Negative *2 Weigh sample and add alkaline solution Definite temp. extraction Weigh sample and add organic solvent By Soxhlet extraction or Solvent extraction Make up with deionized water By boiling water extraction Cool and filter the extract Concentrate the extract and make up with organic solvent Analyzed by ICP-OES Analyzed by GC-MSD Make up with deionized water and add diphenylcarbazide solution Analyzed by UV-VIS Remarks: *1: List of Appropriate Acid: Material Acid Added for Digestion Polymers HNO 3, HCl,HF,H 2 O 2, H 3 BO 3 Metals HNO 3, HCl,HF Electronics HNO 3, HCl,H 2 O 2, HBF 4 *2: If the result of spot test is positive, Chromium VI would be determined as detected. *THJ * Page 5 of 9 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 114 台北市內湖區瑞光路 423 號 8 樓
32 (Ⅳ) Measurement Flowchart: Number : TWNC Test for Halogen Content Reference Standard:EN Sampling/grinding or cutting Add absorbent in a combustion flask & place weighed sample in equipment Fill oxygen into calorimetric bomb Ignite then leave the bomb at room temperature Transfer the absorbent into a volumetric flask Make up with deionized water Analyzed by ion chromatography *THJ * Page 6 of 9 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 114 台北市內湖區瑞光路 423 號 8 樓
33 (Ⅳ) Measurement Flowchart: Number : TWNC Test For Phthalates Contents Reference Method: EN 14372: 2004 Sampling/grinding or cutting Weigh sample and add organic solvent By solvent extraction Concentrate the extract and make up with organic solvent Analyzed by GC-MSD *THJ * Page 7 of 9 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 114 台北市內湖區瑞光路 423 號 8 樓
34 (Ⅳ) Measurement Flowchart: Number : TWNC Test For Hexabromocyclododecane (HBCDD) Reference Standard:USEPA 3540C Sampling/grinding or cutting Weigh sample and add organic solvent By soxhlet extraction Concentrate the extract and make up with organic solvent Analyzed by GC-MSD End of Report This report is made solely on the basis of your instructions and/or information and materials supplied by you. It is not intended to be a recommendation for any particular course of action. Intertek does not accept a duty of care or any other responsibility to any person other than the Client in respect of this report and only accepts liability to the Client insofar as is expressly contained in the terms and conditions governing Intertek's provision of services to you. Intertek makes no warranties or representations either express or implied with respect to this report save as provided for in those terms and conditions. We have aimed to conduct the Review on a diligent and careful basis and we do not accept any liability to you for any loss arising out of or in connection with this report, in contract, tort, by statute or otherwise, except in the event of our gross negligence or wilful misconduct. *THJ * Page 8 of 9 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 114 台北市內湖區瑞光路 423 號 8 樓
35 Number : TWNC Photo *THJ * Page 9 of 9 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 114 台北市內湖區瑞光路 423 號 8 樓
36 Test Report Number : TWNC Applicant: Littelfuse Philippines Inc. Date : Jun 13, 2013 LIMA Technology Center, Lipa City, Malvar, Batangas Sample Description: One (1) group of submitted samples said to be : Part Description : Socket with pin Part Number : Date Sample Received : Jun 05, 2013 Date Test Started : Jun 06, 2013 : As requested by the applicant, for details please refer to attached pages. Tested Components (1) Black plastic body (2) Coppery metal substrate of pin (3) Silvery plating layer of pin Authorized by: On Behalf of Intertek Testing Services Taiwan Limited K. Y. Liang Director *THJ * Page 1 of 13 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 11492, Taiwan, R.O.C 台北市內湖區瑞光路 423 號 8 樓
37 Test Report Number : TWNC Test Result Summary: Heavy Metal Cadmium (Cd) content Lead (Pb) content Mercury (Hg) content Antimony (Sb) Content Test Item Unit Test Method Chromium VI (Cr 6+ ) content Chromium VI (Cr 6+ ) content ppm ppm ppm ppm ppm mg/kg with 50 cm 2 With reference to IEC 62321: 2008, by microwave digestion and determined by ICP-OES. With reference to IEC 62321: 2008, by microwave digestion and determined by ICP-OES. With reference to IEC 62321: 2008, by microwave digestion and determined by ICP-OES. With reference to USEPA 3052, by microwave digestion and determined by ICP-OES. With reference to IEC 62321: 2008, by alkaline digestion and determined by UV-Vis Spectrophotometer. With reference to IEC 62321: 2008, by boiling water extraction and determined by UV-Vis Spectrophotometer. Result (1) (2) (3) RL Negative Negative 0.02 *THJ * Page 2 of 13 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 11492, Taiwan, R.O.C 台北市內湖區瑞光路 423 號 8 樓
38 Test Report Number : TWNC Test Item Unit Test Method Result (1) (2) (3) RL Polybrominated Biphenyls (PBBs) Monobrominated Biphenyls (MonoBB) ppm Dibrominated Biphenyls (DiBB) ppm Tribrominated Biphenyls (TriBB) ppm Tetrabrominated Biphenyls ppm (TetraBB) With reference to IEC 62321: Pentabrominated Biphenyls ppm 2008, by solvent extraction (PentaBB) and determined by GC-MS and Hexabrominated Biphenyls ppm further HPLC-DAD confirmation (HexaBB) when necessary. Heptabrominated Biphenyls ppm (HeptaBB) Octabrominated Biphenyls (OctaBB) ppm Nonabrominated Biphenyls (NonaBB) ppm Decabrominated Biphenyl (DecaBB) ppm *THJ * Page 3 of 13 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 11492, Taiwan, R.O.C 台北市內湖區瑞光路 423 號 8 樓
39 Test Report Number : TWNC Test Item Unit Test Method Result (1) (2) (3) RL Polybrominated Diphenyl Ethers (PBDEs) Monobrominated Diphenyl Ethers (MonoBDE) ppm Dibrominated Diphenyl Ethers (DiBDE) ppm Tribrominated Diphenyl Ethers (TriBDE) ppm Tetrabrominated Diphenyl Ethers ppm (TetraBDE) With reference to IEC 62321: Pentabrominated Diphenyl Ethers ppm 2008, by solvent extraction (PentaBDE) and determined by GC-MS and Hexabrominated Diphenyl Ethers ppm further HPLC-DAD confirmation (HexaBDE) when necessary. Heptabrominated Diphenyl Ethers ppm (HeptaBDE) Octabrominated Diphenyl Ethers (OctaBDE) ppm Nonabrominated Diphenyl Ethers (NonaBDE) ppm Decabrominated Diphenyl Ether (DecaBDE) ppm Halogen Content Fluorine (F) ppm With reference to EN Chlorine (Cl) ppm 14582:2007 by calorimetric bomb with oxygen and Bromine (Br) ppm determined by Ion Iodine (I) ppm Chromatograph Phthalates Di(2-ethylhexyl) Phthalate (DEHP) ppm With reference to EN 14372: Dibutyl Phthalate (DBP) ppm , by solvent extraction Benzyl Butyl Phthalate (BBP) ppm and determined by GC-MS. Diisobutyl phthalate (DIBP) ppm Others With reference to USEPA Hexabromocyclododecane ppm 3540C, by solvent extraction (HBCDD) and determined by GC-MS *THJ * Page 4 of 13 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 11492, Taiwan, R.O.C 台北市內湖區瑞光路 423 號 8 樓
40 Test Report Number : TWNC Remarks: ppm = parts per million based on weight of tested sample = mg/kg = Not detected RL = Reporting Limit, Quantitation limit of analyte in sample mg/kg with 50cm 2 = milligram per kilogram with 50 square centimeter Negative = A negative test result indicated positive observation was not found at the time of test. Responsibility of Chemist: Kevin Liu/ Irene Chiou/ Vico Lin Date Sample Received : Jun 05, 2013 Test Period : Jun 06, 2013 to Jun 13, 2013 RoHS Limit Restricted Substances Limits Cadmium (Cd) content 0.01% (100ppm) Lead (Pb) content 0.1% (1000ppm) Mercury (Hg) content 0.1% (1000ppm) Chromium VI (Cr 6+ ) content 0.1% (1000ppm) Polybrominated Biphenyls (PBBs) 0.1% (1000ppm) Polybrominated Diphenyl Ethers (PBDEs) 0.1% (1000ppm) The above limits were quoted from Annex II of 2011/65/EU for homogeneous material. *THJ * Page 5 of 13 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 11492, Taiwan, R.O.C 台北市內湖區瑞光路 423 號 8 樓
41 Test Report Measurement Flowchart: Test for Cd/Pb/Hg/Chromium (VI)/PBBs/PBDEs Contents Reference Standard: IEC edition 1.0:2008 Number : TWNC For non-metal part Sample preparation For metal part Take sample and immerse into Aqua Regia, start to strip plating layer Stop the stripping procedure upon color change completely Take the Aqua solution as plating component and stripped body as substrate component PBBs/PBDEs Cr 6+ Cd/Pb/Hg Substrate Plating Weigh sample and add organic solvent Weigh sample and add alkaline solution For different material, digest the sample with appropriate acid *1 Cr 6+ By Soxhlet extraction or Solvent extraction Definite temp. extraction Confirm the tested samples are totally dissolved By spot test Get 50cm 2 sample Negative *2 Concentrate the extract and make up with organic solvent Cool and filter the extract Make up with deionized water By boiling water extraction Analyzed by GC-MS Analyzed by ICP-OES Make up with deionized water and add diphenyl-carbazide solution Remarks: *1: List of Appropriate Acid: Material Acid Added for Digestion Polymers HNO 3,HCl,HF,H2O 2,H3BO 3 Metals HNO 3,HCl,HF Electronics HNO 3,HCl,H 2 O 2,HBF 4 Analyzed by UV-VIS *2: If the result of spot test is positive, Chromium VI would be determined as detected. *THJ * Page 6 of 13 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 11492, Taiwan, R.O.C 台北市內湖區瑞光路 423 號 8 樓
42 Test Report Measurement Flowchart: Number : TWNC Test for Heavy Metal (Sb ) Contents Reference Method:USEPA 3052 Sampling Weigh sample and digest in microwave digestion oven with suitable acid Confirm the tested samples are totally dissolved Transfer the digested solution and make up with deionized water Analyzed by ICP-OES *THJ * Page 7 of 13 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 11492, Taiwan, R.O.C 台北市內湖區瑞光路 423 號 8 樓
43 Test Report Measurement Flowchart: Number : TWNC Test for Halogen Content Reference Method:EN Sampling Add absorbent in a combustion flask & place weighed sample in equipment Fill oxygen into calorimetric bomb Ignite then leave the bomb at room temperature Transfer the absorbent into a volumetric flask Make up with deionized water Analyzed by ion chromatography *THJ * Page 8 of 13 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 11492, Taiwan, R.O.C 台北市內湖區瑞光路 423 號 8 樓
44 Test Report Measurement Flowchart: Number : TWNC Test for Phthalates Contents Reference Method: EN 14372: 2004 Sampling Weigh sample and add organic solvent By solvent extraction Concentrate the extract and make up with organic solvent Analyzed by GC-MS *THJ * Page 9 of 13 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 11492, Taiwan, R.O.C 台北市內湖區瑞光路 423 號 8 樓
45 Test Report Measurement Flowchart: Number : TWNC Test for Hexabromocyclododecane (HBCDD) Reference Method:USEPA 3540C Sampling Weigh sample and add organic solvent By soxhlet extraction Concentrate the extract and make up with organic solvent Analyzed by GC-MS *THJ * Page 10 of 13 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 11492, Taiwan, R.O.C 台北市內湖區瑞光路 423 號 8 樓
46 Test Report Number : TWNC (1) (2) (1) (2)(3) End of Report This report is made solely on the basis of your instructions and/or information and materials supplied by you. It is not intended to be a recommendation for any particular course of action. Intertek does not accept a duty of care or any other responsibility to any person other than the Client in respect of this report and only accepts liability to the Client insofar as is expressly contained in the terms and conditions governing Intertek's provision of services to you. Intertek makes no warranties or representations either express or implied with respect to this report save as provided for in those terms and conditions. We have aimed to conduct the Review on a diligent and careful basis and we do not accept any liability to you for any loss arising out of or in connection with this report, in contract, tort, by statute or otherwise, except in the event of our gross negligence or wilful misconduct. *THJ * Page 11 of 13 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 11492, Taiwan, R.O.C 台北市內湖區瑞光路 423 號 8 樓
47 Test Report Number : TWNC Applicant: Littelfuse Philippines Inc. Date : Oct 31, 2012 LIMA Technology Center, Lipa City, Malvar, Batangas Sample Description: One (1) group of submitted samples said to be : Part Description : Ceramic paper Part Number : Date Sample Received : Oct 24, 2012 Date Test Started : Oct 25, 2012 : As requested by the applicant, for details please refer to attached pages. Authorized By: On Behalf Of Intertek Testing Services Taiwan Limited K. Y. Liang Director *THJ * Page 1 of 7 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 114 台北市內湖區瑞光路 423 號 8 樓
48 (Ⅰ) Test Result Summary : Test Item Heavy Metal Cadmium (Cd) content Lead (Pb) content Mercury (Hg) content Chromium VI (Cr 6+ ) content Polybrominated Biphenyls (PBBs) Monobrominated Biphenyls (MonoBB) Dibrominated Biphenyls (DiBB) Tribrominated Biphenyls (TriBB) Tetrabrominated Biphenyls (TetraBB) Pentabrominated Biphenyls (PentaBB) Hexabrominated Biphenyls (HexaBB) Heptabrominated Biphenyls (HeptaBB) Octabrominated Biphenyls (OctaBB) Nonabrominated Biphenyls (NonaBB) Decabrominated Biphenyl (DecaBB) Polybrominated Diphenyl Ethers (PBDEs) Monobrominated Diphenyl Ethers (MonoBDE) Dibrominated Diphenyl Ethers (DiBDE) Tribrominated Diphenyl Ethers (TriBDE) Tetrabrominated Diphenyl Ethers (TetraBDE) Pentabrominated Diphenyl Ethers (PentaBDE) Hexabrominated Diphenyl Ethers (HexaBDE) Heptabrominated Diphenyl Ethers (HeptaBDE) Octabrominated Diphenyl Ethers (OctaBDE) Nonabrominated Diphenyl Ethers (NonaBDE) Decabrominated Diphenyl Ether (DecaBDE) Halogen Content Fluorine (F) Chlorine (Cl) Bromine (Br) Iodine (I) Number : TWNC Result (ppm) White Ceramic Paper Remarks: ppm = Parts per million based on weight of tested sample = mg/kg = Not detected Responsibility of Chemist : Irene Chiou / Kevin Liu / Cathy Chen Date Sample Received : Oct 24, 2012 Test Period : Oct 25, 2012 To Oct 30, 2012 *THJ * Page 2 of 7 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 114 台北市內湖區瑞光路 423 號 8 樓
49 (Ⅱ) RoHS Limits: Restricted Substances Cadmium (Cd) Content Lead (Pb) Content Mercury (Hg) Content Chromium VI (Cr 6+ ) Content Polybrominated Biphenyls (PBBs) Polybrominated Diphenyl Ehters (PBDEs) Number : TWNC Limits 0.01% (100ppm) 0.1% (1000ppm) 0.1% (1000ppm) 0.1% (1000ppm) 0.1% (1000ppm) 0.1% (1000ppm) The above limits were quoted from Annex II of 2011/65/EU for homogeneous material. (Ⅲ) Test Method: Test Item Test Method Reporting Limit With reference to IEC edition 1.0:2008 in clause 8/9/10, by Cadmium (Cd) microwave digestion until the tested content samples are totally dissolved and 2 ppm determined by ICP-OES. Lead (Pb) content With reference to IEC edition 1.0:2008 in clause 8/9/10, by microwave digestion until the tested samples are totally dissolved and 2 ppm Mercury (Hg) content Chromium VI (Cr 6+ ) content determined by ICP-OES. With reference to IEC edition 1.0:2008 in clause 7, by microwave digestion until the tested samples are totally dissolved and determined by ICP-OES. With reference to IEC edition 1.0:2008 in annex C, by alkaline digestion and determined by UV-Vis spectrophotometer. 2 ppm 1 ppm *THJ * Page 3 of 7 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 114 台北市內湖區瑞光路 423 號 8 樓
50 Number : TWNC (Ⅲ) Test Method: Test Item Test Method Reporting Limit With reference to IEC edition 1.0:2008 in annex A, by solvent Polybrominated extraction and determined by GC-MS Biphenyls (PBBs) and further HPLC-DAD confirmation 5 ppm when necessary. Polybrominated Diphenyl Ethers (PBDEs) Halogen Content With reference to IEC edition 1.0:2008 in annex A, by solvent extraction and determined by GC-MS and further HPLC-DAD confirmation when necessary. With reference to EN 14582:2007 by calorimetric bomb with oxygen and determined by Ion Chromatograph. Remark: Reporting limit = Quantitation limit of analyte in sample 5 ppm 50 ppm *THJ * Page 4 of 7 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 114 台北市內湖區瑞光路 423 號 8 樓
51 Number : TWNC (Ⅳ) Measurement Flowchart: Test for Cd/Pb/Hg/Chromium (VI)/PBBS/PBDES Contents Reference Standard: IEC edition 1.0:2008 For metal part Sample preparation For non-metal part Take sample and immerse into Aqua Regia, start to strip plating layer Stop the stripping procedure upon color change completely Take the Aqua solution as plating component and stripped body as substrate component Cd/Pb/Hg Metal Cr 6+ Polymers / electronics PBBs/PBDEs For different material, digest the sample with appropriate acid *1 Confirm the tested samples are totally dissolved By spot test Get 50cm 2 sample Negative *2 Weigh sample and add alkaline solution Definite temp. extraction Weigh sample and add organic solvent By Soxhlet extraction or Solvent extraction Make up with deionized water By boiling water extraction Cool and filter the extract Concentrate the extract and make up with organic solvent Analyzed by ICP-OES Analyzed by GC-MSD Make up with deionized water and add diphenylcarbazide solution Analyzed by UV-VIS Remarks: *1: List of Appropriate Acid: Material Acid Added for Digestion Polymers HNO 3, HCl,HF,H 2 O 2, H 3 BO 3 Metals HNO 3, HCl,HF Electronics HNO 3, HCl,H 2 O 2, HBF 4 *2: If the result of spot test is positive, Chromium VI would be determined as detected. *THJ * Page 5 of 7 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 114 台北市內湖區瑞光路 423 號 8 樓
52 (Ⅳ) Measurement Flowchart: Number : TWNC Test for Halogen Content Reference Standard:EN Sampling/grinding or cutting Add absorbent in a combustion flask & place weighed sample in equipment Fill oxygen into calorimetric bomb Ignite then leave the bomb at room temperature Transfer the absorbent into a volumetric flask Make up with deionized water Analyzed by ion chromatography End of Report This report is made solely on the basis of your instructions and/or information and materials supplied by you. It is not intended to be a recommendation for any particular course of action. Intertek does not accept a duty of care or any other responsibility to any person other than the Client in respect of this report and only accepts liability to the Client insofar as is expressly contained in the terms and conditions governing Intertek's provision of services to you. Intertek makes no warranties or representations either express or implied with respect to this report save as provided for in those terms and conditions. We have aimed to conduct the Review on a diligent and careful basis and we do not accept any liability to you for any loss arising out of or in connection with this report, in contract, tort, by statute or otherwise, except in the event of our gross negligence or wilful misconduct. *THJ * Page 6 of 7 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 114 台北市內湖區瑞光路 423 號 8 樓
53 Number : TWNC Photo *THJ * Page 7 of 7 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 114 台北市內湖區瑞光路 423 號 8 樓
ICP Test Report Certification Packet
ICP Test Report Certification Packet Company name : Littelfuse, Inc. Product Series: Mini PCB Holder 153 series Product #: 01530008Z_01530007Z Issue Date: November 12, 2012 It is hereby certified by Littelfuse,
More informationICP Test Report Certification Packet
ICP Test Report Certification Packet Company name : Littelfuse, Inc. Product Series: TR5 Product #: 370xxxxx Series Issue Date: November 12, 2013 It is hereby certified by Littelfuse, Inc. that there is
More informationICP Test Report Certification Packet
ICP Test Report Certification Packet Company name : Littelfuse, Inc. Product Series: ATOF Product #: 287xxx Series Issue Date: February 25, 2013 It is hereby certified by Littelfuse, Inc. that there is
More informationICP Test Report Certification Packet
ICP Test Report Certification Packet Company name : Littelfuse, Inc. Product Series: Omni Block Fuseholder Product #: 520 OMNI Block series Issue Date: April 14, 2014 It is hereby certified by Littelfuse,
More informationICP Test Report Certification Packet
ICP Test Report Certification Packet Company name : Littelfuse, Inc. Product Series: ATOF Product #: 287xxx Series Issue Date: October 23, 2013 It is hereby certified by Littelfuse, Inc. that there is
More informationTest Report. As per applicant s request
Applicant: Sigma Ink Corporation Date : Nov 19, 2014 674 Via De La Valle Ste 100, Solana Beach, CA 92075 USA Sample Description: One (1) group of submitted samples said to be : Sample Description : UV
More informationICP Test Report Certification Packet
ICP Test Report Certification Packet Company name : Littelfuse, Inc. Product Series: 3AG Holder Product #: 340 Series Issue Date: November 8, 2012 It is hereby certified by Littelfuse, Inc. that there
More informationICP Test Report Certification Packet
ICP Test Report Certification Packet Company name : Littelfuse, Inc. Product Series: TR5 Product #: 372xxxxx Series Issue Date: June 15, 2013 It is hereby certified by Littelfuse, Inc. that there is neither
More informationICP Test Report Certification Packet
ICP Test Report Certification Packet Company name: Suzhou Good-Ark Electronics Co.,Ltd. Product Series: Plastic Minimelf Series Product #: Plastic Minimelf Diode Issue Date: Sep 14, 2012 It is hereby certified
More informationICP Test Report Certification Packet
ICP Test Report Certification Packet Company name: Suzhou Good-Ark Electronics Co.,Ltd. Product Series: SMB SMC Series Product #: SMX GPP(TVS) Diode Issue Date: Sep 1, 2012 It is hereby certified by Suzhou
More informationICP Test Report Certification Packet
ICP Test Report Certification Packet Company name : Littelfuse, Inc. Product Series: PTC Device Product #: RLD Series 16R, 30R, 60R, 72R, 250R, 600R Issue Date: March 26, 2012 It is hereby certified by
More informationMATERIAL DECLARATION & RoHS REPORT
MATERIAL DECLARATION & RoHS REPORT Product Part Number 2038-XX-SMLF Product Line Gas Discharge Tube MSL 1 RoHS Compliant Yes Compliance Date May-2015 No. Construction Element (subpart) 1 Lateral Electrodes
More informationICP Test Report Certification Packet
ICP Test Report Certification Packet Company name : Littelfuse, Inc. Product Series: TR5 Product #: 373xxxxxxx Issue Date: February 8, 2013 It is hereby certified by Littelfuse, Inc. that there is neither
More informationICP Test Report Certification Packet
ICP Test Report Certification Packet Company name : Littelfuse, Inc. Product Series: Pico Product #: 473xxxL Series Issue Date: February 16, 2011 It is hereby certified by Littelfuse, Inc. that there is
More informationTest Report. Applicant : RECOM Engineering GmbH & Co. KG. Date : Jun 03, 2016
Applicant : RECOM Engineering GmbH & Co. KG. Date : Jun 03, 2016 Münzfeld 35 4810 Gmunden AUSTRIA This is to supersede Report No. TWNC00519736 Dated May 16, 2016 Sample Description : One (1) group of submitted
More informationICP Test Report Certification Packet
ICP Test Report Certification Packet Company name : Littelfuse, Inc. Product Series: SMBJ, P6SMB, SACB, 3T, 1KSMB, HTVSB7.0CA-100 Series Product #: TVS Diode Issue Date: August 2, 2014 It is hereby certified
More informationICP Test Report Certification Packet
ICP Test Report Certification Packet Company name : Littelfuse, Inc. Product Series: 327 series (Micro2 Fuses) Product #: 327 series (Micro2 Fuses) Issue Date: December 8, 2011 It is hereby certified by
More informationTEST REPORT NUMBER: SHAH DATE: AUG 18, 2008 APPLICANT: LITEON SEMICONDUCTOR CORP. 28-1, WU SHIN STREET, TA WU LUNG, KEELUNG 204, TAIWAN, R.O.
APPLICANT: LITEON SEMICOUCTOR CORP. 28-1, WU SHIN STREET, TA WU LUNG, KEELUNG 204, TAIWAN, R.O.C DATE: AUG 18, 2008 SHANGHAI SEEFULL ELECTRONIC CO.,LTD. 6 ZHENGYE RD., DONGJING, SONGJIANG DISTRICT, SHANGHAI,
More informationICP Test Report Certification Packet
ICP Test Report Certification Packet Company name : Littelfuse, Inc. Product Series: SMBJ, P6SMB, SACB, 3T, 1KSMB, HTVSB7.0CA-100 Series Product #: TVS Diode Issue Date: August 27, 2013 It is hereby certified
More informationTEST REPORT NUMBER: SHAH S1 APPLICANT: LITEON SEMICONDUCTOR CORP. 28-1, WU SHIN STREET, TA WU LUNG, KEELUNG 204, TAIWAN, R.O.
APPLICANT: LITEON SEMICOUCTOR CORP. 28-1, WU SHIN STREET, TA WU LUNG, KEELUNG 204, TAIWAN, R.O.C DATE: AUG 20, 2008 SHANGHAI SEEFULL ELECTRONIC CO.,LTD. 6 ZHENGYE RD., DONGJING, SONGJIANG DISTRICT, SHANGHAI,
More informationICP Test Report Certification Packet
ICP Test Report Certification Packet Company name : Littelfuse, Inc. Product Series: 3.6 x 10 mm Fuse Product #: 875xxx Series Issue Date: April 21, 2014 It is hereby certified by Littelfuse, Inc. that
More informationICP Test Report Certification Packet
ICP Test Report Certification Packet Company name : Littelfuse, Inc. Product Series: Low Profile Minifuse Product #: 891xxx Series Issue Date: July 27, 2011 It is hereby certified by Littelfuse, Inc. that
More informationTEST REPORT NUMBER: SHAH S1 APPLICANT: LITEON SEMICONDUCTOR CORP. 28-1, WU SHIN STREET, TA WU LUNG, KEELUNG 204, TAIWAN, R.O.
APPLICANT: LITEON SEMICOUCTOR CORP. 28-1, WU SHIN STREET, TA WU LUNG, KEELUNG 204, TAIWAN, R.O.C DATE: AUG 20, 2008 SHANGHAI SEEFULL ELECTRONIC CO.,LTD. 6 ZHENGYE RD., DONGJING, SONGJIANG DISTRICT, SHANGHAI,
More informationICP Test Report Certification Packet
ICP Test Report Certification Packet Company name : Littelfuse, Inc. Product Series: Varistors Product #: VxxZXxxP Series Issue Date: May 18, 2010 It is hereby certified by Littelfuse, Inc. that there
More informationICP Test Report Certification Packet
Company Name: Littelfuse, Inc. ICP Test Report Certification Packet Product Type: Surface Mount Varistors Product Series: CH Series RoHS Compliant Models Issue Date: June 4, 2010 It is hereby certified
More informationICP Test Report Certification Packet
ICP Test Report Certification Packet Company name : Littelfuse, Inc. Product Series: PulseGuard ESD Protector Product #: PGB1010402KR Series Issue Date: July 26, 2013 It is hereby certified by Littelfuse,
More informationIntertek Testing Services Ltd., Shanghai TFH Division Block B, Jinling Business Square,No.801 Yi Shan Road, Shanghai, China, 200233 Tel: +86 21 6120 6565 Fax: +86 21 6127 9740 E-mail: labtest.shanghai@intertek.com
More informationICP Test Report Certification Packet
ICP Test Report Certification Packet Company name : Littelfuse, Inc. Product Series: Low Profile Minifuse Product #: 891xxx Series Issue Date: August 15, 2012 It is hereby certified by Littelfuse, Inc.
More informationCertificate of non-use of The Controlled Substances
Certificate of non-use of The Controlled Substances Company name Littelfuse, Inc. Product Covered SIDACtor, QFN Package PLED, QFN Package Issue Date May 04, 2013 It is hereby certified by Littelfuse, Inc.,
More informationTest Report Number: SHAH Applicant: TE CONNECTIVITY Date: 22 Feb, 2017 BUILDING A5,NO.1528 GUMEI ROAD, SHANGHAI,CHINA Attn: CC WU
Applicant: TE CONNECTIVITY Date: 22 Feb, 2017 BUILDING A5,NO.1528 GUMEI ROAD, SHANGHAI,CHINA Attn: CC WU Sample Description: Three( 3 ) groups of submitted sample said to be : A.White plastic(171370-3)
More informationICP Test Report Certification Packet
ICP Test Report Certification Packet Company name : Littelfuse, Inc. Product Series: ATO Product #: 257xxx Series Issue Date: July 25, 2012 It is hereby certified by Littelfuse, Inc. that there is neither
More informationICP Test Report Certification Packet
ICP Test Report Certification Packet Company name : Littelfuse, Inc. Product Series: ATOF Product #: 287xxx Series Issue Date: November 14, 2012 It is hereby certified by Littelfuse, Inc. that there is
More informationICP Test Report Certification Packet
ICP Test Report Certification Packet Company name : Littelfuse, Inc. Product Series: Compact 3.6 x 10 mm Single Pigtail Fuse Product #: 877xxx Series Issue Date: February 5, 2013 It is hereby certified
More informationCertificate of non-use of The Controlled Substances
Certificate of non-use of The Controlled Substances Company name Product Covered Littelfuse, Inc. SIDACtor, DO-214AA & COMPAK Package SIDAC, DO-214AA Package SiBOD TM, DO-214AA Package, SMTBJ series Thyristor,
More informationCertificate of non-use of The Controlled Substances
Certificate of non-use of The Controlled Substances Company name Product Covered Littelfuse, Inc Thyristor TO-220 L Package (Isolated) Thyristor TO-220 R Package (Non-isolated) Thyristor TO-263 N Package
More informationTEST REPORT NUMBER: SHAH TESTS CONDUCTED. (A) TEST RESULT SUMMARY FOR RoHS DIRECTIVE:
TESTS COUCTED (A) TEST RESULT SUMMARY FOR RoHS DIRECTIVE: TESTING ITEM RESULT (ppm) (1) CADMIUM (Cd) CONTENT (ppm) (
More informationTEST REPORT. Page : 1 of 9 Report No. RT14R-U E Date: Oct. 13, : The following submitted sample(s) said to be:-
Applicant Address : PSMC Co., Ltd. : #52, Banyeo-1dong, Haeundae-gu, Busan, Korea Page : 1 of 9 Sample Description : The following submitted sample(s) said to be:- Name/Type of Product Name of Material
More informationICP Test Report Certification Packet
ICP Test Report Certification Packet Company name : Littelfuse, Inc. Product Series: HR600V 30A series Product #: LFH60030xxxx Issue Date: August 28, 2012 It is hereby certified by Littelfuse, Inc. that
More informationTEST REPORT. : The following submitted sample(s) said to be:-
Applicant : Amkor Technology Korea, Inc. Address : 280-8, 2-ga, Seongsu-dong, Seongdong-gu, Seoul, 133-706 Korea Page: 1 of 7 Sample Description : The following submitted sample(s) said to be:- Name/Type
More informationApplicant: Cactus Technologies Ltd Date : Apr 07, 2010 Suite C 15/F Capital Trade Center 62 Tsun Yip Street Kwun Tong Kowloon Hong Kong
RoHS Screening Analysis Report Number : TWNC00152904 Applicant: Cactus Technologies Ltd Date : Apr 07, 2010 Suite C 15/F Capital Trade Center 62 Tsun Yip Street Kwun Tong Kowloon Hong Kong Sample Description:
More informationTEST REPORT Reference No. : TRHZ Date : Sep. 18, 2013 Page No. : 1 of 5
Reference No. : TRHZ1309618 Date : Sep. 18, 2013 Page No. : 1 of 5 Client : Address : TEFLEX GASKET CO., LTD. CIE INDUSTRIAL ZONE, CIXI CITY, ZHEJIANG, CHINA. The following merchandise was (were) submitted
More informationAPPLICANT: CACTUS TECHNOLOGIES LTD DATE : JUL 25, 2007 SUITE /F BILLION TRADE CENTER 31 HUNG TO ROAD KWUN TONG KOWLOON HONG KONG
XRF SCREENING AND CHEMICAL CONFIRMATION REPORT NUMBER : APPLICANT: CACTUS TECHNOLOGIES LTD DATE : JUL 25, 2007 SUITE 2002 20/F BILLION TRADE CENTER 31 HUNG TO ROAD KWUN TONG KOWLOON HONG KONG SAMPLE DESCRIPTION:
More informationICP Test Report Certification Packet
ICP Test Report Certification Packet Company name : Littelfuse, Inc. Product Series: 3AB Cartridge Product #: 322xxxP Series Issue Date: January 4, 2014 It is hereby certified by Littelfuse, Inc. that
More information: DAM1-125,DAM1-160,DAM1-400,DAM1-630,DAM1-800, DAM1-1600
Applicant: Shanghai DADA Electric CO.,Ltd. Date: Aug 10, 2015 No 171,Yezhuang Road, Zhuanghang, Fengxian, Shanghai, China Sample Description: One (1) piece of submitted sample said to be Item Name : Moulded
More informationTEST REPORT. : The following submitted sample(s) said to be:- SAMPLE RECEIVED : Jan. 07, 2019 TESTING DATE : Jan. 07, 2019 ~ Jan.
APPLICANT : KOSTIC KOREA LTD. ADDRESS : 185, Pungmu-ro, Gimpo-si, Gyeonggi-do, Korea PAGE: 1 of 8 SAMPLE DESCRIPTION : The following submitted sample(s) said to be:- NAME/TYPE OF PRODUCT SAMPLE ID NO.
More informationICP Test Report Certification Packet
ICP Test Report Certification Packet Company name : Littelfuse, Inc. Product Series: Sate T-Plus Fuse Product #: 259xxx Series Issue Date: September 5, 2011 It is hereby certified by Littelfuse, Inc. that
More informationTest Report No. : KE/2016/B2076 Date : 2016/11/24 Page : 2 of 8 Test Result(s) PART NAME NO.1 : GRAY Test Item (s): Unit Method Cadmium (Cd) mg/kg Wit
Test Report No. : KE/2016/B2076 Date : 2016/11/24 Page : 1 of 8 The following sample(s) was/were submitted and identified by/on behalf of the client as : Sample Description : Lot No. : Material Component
More informationTEST REPORT. : Lead Frame / Ag is plated on Ni-Fe Alloy-A42 material
APPLICANT : PSMC CO., LTD. ADDRESS : 16, Barangongdan-ro 4-gil, Hyangnam-eup, Hwaseong-si, Gyeonggi-do, Korea PAGE: 1 of 10 SAMPLE DESCRIPTION : The following submitted sample(s) said to be:- NAME/TYPE
More informationICP Test Report Certification Packet
ICP Test Report Certification Packet Company name : Littelfuse, Inc. Product Series: ATOF Product #: 287xxx Series Issue Date: August 7, 2012 It is hereby certified by Littelfuse, Inc. that there is neither
More informationPage 2 of 12 Test Result(s) PART NAME No.1 IC TRANSCEIVER Test Item(s) Cadmium (Cd) Unit Method With reference to IEC (2013) and performed by
Page 1 of 12 The following samples was/were submitted and identified by/on behalf of the applicant as Sample Submitted By Sample Description Style/Item No. Buyer/Order No. Other Info. Sample Receiving
More informationTEST REPORT. Address : , Doksan-dong, Geumcheon-gu, Seoul, Korea Page: 1 of 12 Report No. RT16R-S E Date: Jul.
Applicant : Young Yiel Precision Address : 1001-10, Doksan-dong, Geumcheon-gu, Seoul, Korea Page: 1 of 12 : The following submitted sample(s) said to be:- Name/Type of Product Name of Material Item No.
More informationTest Report No. : CE/2014/B4428 Date : 2014/12/03 Page : 1 of 12 PELNOX CO., LTD. 8-7 BODAI, HADANO CITY, KANAGAWA , JAPAN *CE/2014/B4428* The
Test Report No. : CE/2014/B4428 Date : 2014/12/03 Page : 1 of 12 The following sample(s) was/were submitted and identified by/on behalf of the applicant as : Sample Description Style/Item No. Sample Receiving
More informationPage 2 of 11 Test Result(s) PART NAME No.1 TRANSPARENT-YELLOW PASTE Cadmium (Cd) Lead (Pb) Mercury (Hg) Test Item(s) Hexavalent Chromium Cr(VI) Sum of
Page 1 of 11 The following samples was/were submitted and identified by/on behalf of the applicant as Sample Submitted By Sample Description Style/Item No. Sample Receiving Date Testing Period TSF 6592LV
More informationICP Test Report Certification Packet
ICP Test Report Certification Packet Company name : Littelfuse, Inc. Product Series: Pico Product #: 473xxxHF Series Issue Date: May 23, 2011 It is hereby certified by Littelfuse, Inc. that there is neither
More informationCertificate of non-use of The Controlled Substances
Certificate of non-use of The Controlled Substances Company name Littelfuse, Inc. Product Covered SIDACtor, QFN Package PLED, QFN Package Issue Date February 8, 2014 It is hereby certified by Littelfuse,
More informationICP Test Report Certification Packet
ICP Test Report Certification Packet Company name : Littelfuse, Inc. Product Series: Class J Fast-Acting Fuse Product #: JLS SERIES Issue Date: June 1, 2012 It is hereby certified by Littelfuse, Inc. that
More informationPage 2 of 9 Test Result(s) PART NAME No.1 DARK BROWN PASTE Test Item(s) Cadmium (Cd) Lead (Pb) Unit Method With reference to IEC (2013) and pe
Page 1 of 9 The following samples was/were submitted and identified by/on behalf of the applicant as Sample Submitted By Sample Description Style/Item No. Sample Receiving Date Testing Period TSF-6522
More informationPage 2 of 12 Test Result(s) PART NAME No.1 DK. BROWN LUMP Cadmium (Cd) Lead (Pb) Mercury (Hg) Antimony (Sb) Beryllium (Be) Test Item(s) Hexavalent Chr
Page 1 of 12 The following samples was/were submitted and identified by/on behalf of the applicant as Sample Submitted By Sample Description Style/Item No. Sample Receiving Date Testing Period ELEKTRISOLA
More informationChemical Laboratory - Kao., SGS Taiwan Ltd. Test Report No. : KE/2017/40842 Date : 2017/04/17 ROGERS CORPORATION 245 WOODSTOCK ROAD, WOODSTOCK, CT. 06
Page: 1 of 7 The following sample(s) was/were submitted and identified by/on behalf of the client as : Sample Description : Style/Item No. : Color : Sample Receiving Date : Testing Period : Sample Submitted
More informationTEST REPORT. ADDRESS : 77, Seokam-ro 13-gil, Iksan, Jeonllabuk-do, Korea PAGE: 1 of 8 REPORT NO. RT17R-U2181-E DATE: Dec. 29, 2017
APPLICANT : CALIX ELECTRONIC CHEMICAL CO., LTD. ADDRESS : 77, Seokam-ro 13-gil, Iksan, Jeonllabuk-do, Korea PAGE: 1 of 8 SAMPLE DESCRIPTION : The following submitted sample(s) said to be:- NAME/TYPE OF
More informationPage 2 of 12 Test Result(s) PART NAME No.1 YELLOW LUMP Test Item(s) Cadmium (Cd) Lead (Pb) Mercury (Hg) Hexavalent Chromium Cr(VI) Sum of PBBs Monobro
Page 1 of 12 The following samples was/were submitted and identified by/on behalf of the applicant as Sample Submitted By Sample Description Style/Item No. Sample Receiving Date Testing Period ELEKTRISOLA
More informationICP Test Report Certification Packet
ICP Test Report Certification Packet Company name : Littelfuse, Inc. Product Series: Inrush Protector Product #: 399xxxxxxx Series Issue Date: Spetember 5, 2011 It is hereby certified by Littelfuse, Inc.
More informationPage 2 of 8 Test Result(s) PART NAME No.1 SILVER COLORED PASTE Cadmium (Cd) Lead (Pb) Mercury (Hg) Test Item(s) Hexavalent Chromium Cr(VI) Sum of PBBs
Page 1 of 8 The following samples was/were submitted and identified by/on behalf of the applicant as Sample Submitted By Sample Description Style/Item No. Sample Receiving Date Testing Period DIE BONDING
More informationTest Report No. : KA/2014/61579 Date : 2014/07/07 Page : 2 of 14 Test Result(s) PART NAME NO.1 : GOLD BONDING WIRE Test Item (s): Unit Method Cadmium
Test Report No. : KA/2014/61579 Date : 2014/07/07 Page : 1 of 14 The following sample(s) was/were submitted and identified by/on behalf of the client as : Sample Description : Style/Item No. : Color :
More informationChemical Laboratory - Kao., SGS Taiwan Ltd. Test Report No. : KA/2017/50850 Date : 2017/05/25 HERAEUS MATERIALS SINGAPORE PTE LTD BLOCK 5002, ANG MO K
Page 1 of 14 The following sample(s) was/were submitted and identified by/on behalf of the applicant as Sample Description Style/Item No. Color Sample Receiving Date Testing Period Sample Submitted By
More informationICP Test Report Certification Packet
ICP Test Report Certification Packet Company name : Littelfuse, Inc. Product Series: ATO Product #: 257xxx Series Issue Date: July 19, 2013 It is hereby certified by Littelfuse, Inc. that there is neither
More informationTest Report No. : KA/2012/21431 Date : 2012/02/24 Page : 2 of 12 Test Result(s) PART NAME NO.1 : SILVER GRAY DIE ATTACH PASTE Test Item (s): Unit Meth
Test Report No. : KA/2012/21431 Date : 2012/02/24 Page : 1 of 12 The following sample(s) was/were submitted and identified by/on behalf of the client as : Sample Description : Style/Item No. : Sample Receiving
More informationTest Report No. : CE/2014/50660 Date : 2014/05/22 Page : 2 of 14 Test Result(s) PART NAME No.1 Cadmium (Cd) Lead (Pb) Mercury (Hg) Antimony (Sb) Test
Test Report No. : CE/2014/50660 Date : 2014/05/22 Page : 1 of 14 The following sample(s) was/were submitted and identified by/on behalf of the applicant as : Sample Submitted By Sample Description Style/Item
More informationPage 2 of 12 Test Result(s) PART NAME No.1 INTEGRATED CIRCUITS Test Item(s) Cadmium (Cd) Lead (Pb) Mercury (Hg) Hexavalent Chromium Cr(VI) Sum of PBBs
Page 1 of 12 The following samples was/were submitted and identified by/on behalf of the applicant as Sample Submitted By Sample Description Style/Item No. Buyer/Order No. Other Info. Sample Receiving
More informationICP Test Report Certification Packet
ICP Test Report Certification Packet Company name : Littelfuse, Inc. Product Series: Class CC Fuse TD 600 VAC Product #: KLDR Series (except 20A & 8-15A) Issue Date: May 31, 2012 It is hereby certified
More informationPage 2 of 10 Test Result(s) PART NAME No.1 TRANSPARENT-YELLOW PASTE Cadmium (Cd) Lead (Pb) Mercury (Hg) Test Item(s) Hexavalent Chromium Cr(VI) Sum of
Page 1 of 10 The following samples was/were submitted and identified by/on behalf of the applicant as Sample Submitted By Sample Description Style/Item No. Sample Receiving Date Testing Period TSF 6502JCR
More informationChemical Laboratory - Kao., Page 2 of 14 Test Result(s) PART NAME No.1 SILVER COLORED PASTE Cadmium (Cd) Test Item(s) Unit Method mg/kg With reference
Chemical Laboratory - Kao., Page 1 of 14 The following sample(s) was/were submitted and identified by/on behalf of the applicant as Sample Description Style/Item No. Sample Receiving Date Testing Period
More informationPage 2 of 12 Test Result(s) PART NAME No.1 INTEGRATED CIRCUITS Test Item(s) Cadmium (Cd) Lead (Pb) Mercury (Hg) Hexavalent Chromium Cr(VI) Sum of PBBs
Page 1 of 12 The following samples was/were submitted and identified by/on behalf of the applicant as Sample Submitted By Sample Description Style/Item No. Buyer/Order No. Other Info. Sample Receiving
More informationPage 2 of 12 Test Result(s) PART NAME No.1 INTEGRATED CIRCUITS Cadmium (Cd) Lead (Pb) Mercury (Hg) Test Item(s) Hexavalent Chromium Cr(VI) ( ) Sum of
Page 1 of 12 The following samples was/were submitted and identified by/on behalf of the applicant as Sample Submitted By Sample Description Style/Item No. Buyer/Order No. Other Info. Sample Receiving
More informationPage 2 of 12 Test Result(s) PART NAME No.1 INTEGRATED CIRCUITS Test Item(s) Cadmium (Cd) Unit Method With reference to IEC (2013) and performe
Page 1 of 12 The following samples was/were submitted and identified by/on behalf of the applicant as Sample Submitted By Sample Description Style/Item No. Buyer/Order No. Other Info. Sample Receiving
More informationTEST REPORT. * Note 2 : This report shall not be reproduced except in full without the written approval of the testing laboratory.
APPLICANT : PILKOR Electronics Division. (of COWELL Fashion Co., Ltd.) ADDRESS : 270, Sinwon-ro(Woncheon-dong), Yeongtong-gu, Suwon-si, Gyeonggi-do, Korea PAGE: 1 of 5 SAMPLE DESCRIPTION : The following
More informationPage 2 of 12 Test Result(s) PART NAME No.1 INTEGRATED CIRCUITS Test Item(s) Cadmium (Cd) Unit Method With reference to IEC (2013) and performe
Page 1 of 12 The following samples was/were submitted and identified by/on behalf of the applicant as Sample Submitted By Sample Description Style/Item No. Buyer/Order No. Other Info. Sample Receiving
More informationTest Report No. : CE/2014/32788 Date : 2014/03/27 Page : 2 of 14 Test Result(s) PART NAME No.1 : YELLOW SHEET Cadmium (Cd) Lead (Pb) Mercury (Hg) Test
Test Report No. : CE/2014/32788 Date : 2014/03/27 Page : 1 of 14 The following sample(s) was/were submitted and identified by/on behalf of the applicant as : Sample Submitted By Sample Description Style/Item
More informationTest Report No. CE/2014/43454A Date 2014/04/23 Page 2 of 11 Test Result(s) PART NAME No.1 MIXED ALL PARTS Cadmium (Cd) Lead (Pb) Mercury (Hg) Test Ite
Test Report No. CE/2014/43454A Date 2014/04/23 Page 1 of 11 The following sample(s) was/were submitted and identified by/on behalf of the applicant as Sample Submitted By Sample Description Style/Item
More informationPage 2 of 12 Test Result(s) PART NAME No.1 INTEGRATED CIRCUITS Cadmium (Cd) Lead (Pb) Test Item(s) Unit Method With reference to IEC (2013) an
Page 1 of 12 The following samples was/were submitted and identified by/on behalf of the applicant as Sample Submitted By Sample Description Style/Item No. Buyer/Order No. Other Info. Sample Receiving
More informationICP Test Report Certification Packet
ICP Test Report Certification Packet Company name : Littelfuse, Inc. Product Series: FUSE - FKS Product #: 162.6185.4xxx Series Issue Date: November 17, 2011 It is hereby certified by Littelfuse, Inc.
More informationTest Report No. : CE/2013/51536 Date : 2013/05/29 Page : 2 of 14 Test Result(s) PART NAME No.1 : YELLOW SHEET Cadmium (Cd) Lead (Pb) Mercury (Hg) Hexa
Test Report No. : CE/2013/51536 Date : 2013/05/29 Page : 1 of 14 The following samples was/were submitted and identified by/on behalf of the applicant as : Sample Submitted By Sample Description Style/Item
More informationChemical Laboratory - Kao., Page 2 of 14 Test Result(s) PART NAME No.1 BLACK EPOXY MOLDING COMPOUND Cadmium (Cd) Test Item(s) Unit Method mg/kg With r
Chemical Laboratory - Kao., Page 1 of 14 The following sample(s) was/were submitted and identified by/on behalf of the applicant as Sample Description Style/Item No. Sample Receiving Date Testing Period
More informationChemical Laboratory - Kao., Page 2 of 14 Test Result(s) PART NAME No.1 BLACK EPOXY MOLDING COMPOUND Test Item(s) Cadmium (Cd) Lead (Pb) Mercury (Hg) H
Chemical Laboratory - Kao., Page 1 of 14 The following sample(s) was/were submitted and identified by/on behalf of the applicant as Sample Description Style/Item No. Sample Receiving Date Testing Period
More informationTest Report. Report No. ECL01H Page 1 of 9
Report No. ECL01H067809001 Page 1 of 9 Applicant Address LITE-ON MICROELECTRONICS (WUXI) CO., LTD. LITE-ON SEMICONDUCTOR CORP. LAND LOT J7 J8WEPZ, NEW DISTRICT, WUXI CITY, JIANGSU, CHINA 9F,NO.233-2 PAO-CHIAO
More informationPage 2 of 9 Test Result(s) PART NAME No.1 SILVER COLORED PASTE Cadmium (Cd) Lead (Pb) Mercury (Hg) Test Item(s) Hexavalent Chromium Cr(VI) Sum of PBBs
Page 1 of 9 The following samples was/were submitted and identified by/on behalf of the applicant as Sample Submitted By Sample Description Style/Item No. Sample Receiving Date Testing Period ADHESIVE
More informationTest Report No. : KA/2012/40043 Date : 2012/04/10 Page : 2 of 8 Test Result(s) PART NAME NO.1 : BLACK EPOXY MOLDING COMPOUNDS Test Item (s): MDL Resul
Test Report No. : KA/2012/40043 Date : 2012/04/10 Page : 1 of 8 The following sample(s) was/were submitted and identified by/on behalf of the client as : Sample Description : Style/Item No. : JP Reference
More informationTest Report No. CE/2016/43515 Date 2016/04/22 Page 2 of 7 Test Result(s) PART NAME No.1 AMBER FILM Test Item(s) Cadmium (Cd) Lead (Pb) Mercury (Hg) He
Test Report No. CE/2016/43515 Date 2016/04/22 Page 1 of 7 The following sample(s) was/were submitted and identified by/on behalf of the applicant as Sample Submitted By Sample Description Color Style/Item
More informationPage : 2 of 12 Test Result(s) PART NAME No.1 : MIXED ALL PARTS Test Item(s) Cadmium (Cd) Unit Method With reference to IEC (2013) and performe
Page : 1 of 12 The following samples was/were submitted and identified by/on behalf of the applicant as : Sample Description Style/Item No. Sample Receiving Date Testing Period : : : : SMD CRYSTAL RESONATOR
More informationChemical Laboratory - Kao., Test Report No. : KE/2018/11379 Date : 2018/01/25 Page : 2 of 8 Test Result(s) PART NAME NO.1 : CLEAR FAL FILM WITH ADHESI
Chemical Laboratory - Kao., Test Report No. : KE/2018/11379 Date : 2018/01/25 Page : 1 of 8 The following sample(s) was/were submitted and identified by/on behalf of the client as : Sample Description
More informationPage 2 of 10 Test Result(s) PART NAME No.1 LT.GRAY SHEET Test Item(s) Cadmium (Cd) Lead (Pb) Unit Method With reference to IEC (2013) and perf
Page 1 of 10 The following samples was/were submitted and identified by/on behalf of the applicant as Sample Submitted By Sample Description Buyer/Order No. Other Info. Sample Receiving Date Testing Period
More informationICP Test Report Certification Packet
ICP Test Report Certification Packet Company name : Littelfuse, Inc. Product Series: 3AB Fuse Product #: 0314030.M52LP Issue Date: September 11, 2014 It is hereby certified by Littelfuse, Inc. that there
More informationTest Report No. CE/2015/C2965A Date 2016/02/16 Page 2 of 7 Test Result(s) PART NAME No.1 MIXED ALL PARTS Cadmium (Cd) Lead (Pb) Mercury (Hg) Test Item
Test Report No. CE/2015/C2965A Date 2016/02/16 Page 1 of 7 The following sample(s) was/were submitted and identified by/on behalf of the applicant as Sample Submitted By Sample Description Style/Item No.
More informationTest Report. Report No. SCL03H Page 1 of 7
Report No. SCL03H004659 Page 1 of 7 Applicant FOSHAN BLUEROCKET ELECTRONICS CO.,LTD Address NO.45 GUXIN ROAD, CHANCHENG DISTRICT, FOSHAN, GUANGDONG, P.R.C. The following sample(s) and sample information
More informationTest Report. Report No. ECL01H Page 1 of 9
Report No. ECL01H067702001 Page 1 of 9 Applicant SHANGHAI SEEFULL ELECTRONIC CO., LTD LITE-ON SEMICONDUCTOR CORP. Address 6 ZHENYE RD. DONGJING INDUSTRIAL AREA SONGJIANG DISTRICT, SHANGHAI, CHINA 9F,NO.233-2
More informationPage 2 of 11 Test Result(s) PART NAME No.1 YELLOW/WHITE PAD (EXCLUDING THE RELEASE FILM) Cadmium (Cd) Lead (Pb) Test Item(s) Unit Method With referenc
Page 1 of 11 The following samples was/were submitted and identified by/on behalf of the applicant as Sample Submitted By Sample Description Buyer/Order No. Other Info. Sample Receiving Date Testing Period
More informationICP Test Report Certification Packet
ICP Test Report Certification Packet Company name : Littelfuse, Inc. Product Series: Time-Delay Midget Fuse Product #: 0KLQ000.T Issue Date: July 10, 2013 It is hereby certified by Littelfuse, Inc. that
More informationTEST REPORT : SR A-DC, SR A-DA, SR A-DT, SR A-DN, SR C-DC, SR C-DA, SR C-DT, SR C-DN
Applicant : UTIS Address : 652-10, Choji-dong, Danwon-ku, Ansan-city, Gyeonggi-do, Korea Page: 1 of 5 Sample Description : The following submitted sample(s) said to be:- Name/Type of Product Sample ID
More information