The Tool Box Getting More Productivity from Your GC and GC/MSD

Size: px
Start display at page:

Download "The Tool Box Getting More Productivity from Your GC and GC/MSD"

Transcription

1 The Tool Box Getting More Productivity from Your GC and GC/MSD M Ramesh Application Engg GC/GCMS Agilent Technologies India Pvt. Ltd. Productivity Tool Box for GC & GC/MSOverview 5975C MSD Agilent Restricted Page 2

2 Defining Productivity More analyses per unit time... Faster and more efficient separations Shorter analysis cycle time (time from injection to injection) Reduced requirement for sample preparation with consistently better results... Quantitative: accuracy, precision, detection limits, linear range Qualitative: response ratios, confirmatory retention times, library searches (eliminate false negatives and false positives) while using less operator time for each analysis. Less time performing maintenance Extensive computer control and data processing Simplified operator review/approval Page 4

3 Productivity: the Sum of Many Technologies Low Thermal Mass GC Capillary Flow Technology - Backflush Hydrogen carrier gas for GC and GC/MS Retention Time Locking (RTL) Editor (& Methods) With more RTL Databases Trace Ion Detection Fast Electronic - Synchronous SIM/Scan Method Translator High signal-to-noise Triple-Axis Detector Gain Normalization of the EM EM Saver 2nd Generation Deconvolution Reporting Software (DRS) Return home (this slide) Next slide Return to section menu Page 5

4 Productivity: Low Thermal Mass GC More analyses per unit time... Faster and better separations Shorter analysis cycle time (time from injection to injection) Reduced requirement for sample preparation with consistently better results... Quantitative: accuracy, precision, detection limits, linear range Qualitative: response ratios, confirmatory retention times, library searches (eliminate false negatives and false positives) while using less operator time for each analysis. Less time performing maintenance Extensive computer control and data processing Simplified operator review/approval Page 6

5 LTM (Low Thermal Mass) Technology Direct heating of fused silica GC columns Page 7

6 Rapid Cooldown LTM Cooldown Times (Standard Size) Temp (oc) Time (sec) 2m LTM 5m LTM 10m LTM 7890 GC Additional Cooldown times available on website for LTM column modules up to 30m Page 8

7 Low Thermal Mass Technology for 7890/6890 GC Satisfies the need for high through-put, especially for low margin samples, where analytical cycle times are a critical element in making a profit Independent and simultaneous temperature programming of: 1-2 column modules (fastest cooldown), or 1-4 column modules (small format) LTM Column Modules (standard width shown) LTM Control System w/ Keypad User Interface Agilent LTM Control SW now available Note: Front thermal shield removed to show LTM column modules Entire thermal shield should always be in place during operation Page 9

8 LTM Also Greatly Reduces Cool-Down Times, 9x Faster Heating/Cooling Cycle Times GC Run Time Cool Down 40 min min 20 min min 3 min + 2 min LTM/7890 9x Faster Cycle Time (200 o C/min) Page 10

9 Obtaining Faster GC, GC/MS Analytical Cycle Times A Variety of Approaches to Fit Your Lab and Your Needs Pre-Run ALS Set-Up Chromatographic Run Post-Run Bake-Out Post-Run Cool-Down Included ALS Sample Overlap in in ChemStation SW HW/SW 7890 GC Faster Cool-down Faster GC Analyses Column Selection, Method Translation GC Add-Ons Signficantly Faster GC Analytical Cycle Times Capillary Flow Technology (Backflush) LTM Technology LTM Technology (Rapid Heating) (Rapid Cooling ) Page 11

10 PAH by LTM/GC/MS Fast Analysis - LTM 20 m x 0.18 mm ID x 0.18 µm DB-5MS Time--> Reference method Standard Oven 30 m x 0.25 mm ID x 0.25 µm DB-5MS Time--> Page 12

11 PAH by LTM/GC/MS Column contamination from just one prior run Contamination free when using backflush Page Time (min)

12 LTM Productivity High efficiency temperature programming Fast cooling High throughput Fast method development High performance chromatography Utilize commercially available columns (typically < 30 m) Easily integrates with conventional GC instruments Utilize existing injectors, detectors, software Multicolumn temperature control Independent optimization Multidimensional GC High throughput parallel systems Page 14

13 Hydrocarbon Processing Industry (HPI) HPI Shorter analytical cycle times get data back to operations faster, or allow more samples/shift (eg. Simulated Distillation) Key Sales Tools EN Fast Hydrocarbon & Sulfur Simulated Distillation Using the Agilent Low Thermal Mass (LTM) System on the 7890A GC and 355 Sulfur Chemiluminescence Detector(Wang,Firor,Tripp - Fast Simdist (< 3 mins), 6x faster than conventional Simdist - Dual channel, simultaneous SimDist for hydrocarb s & sulfur Article (Fall 08) Page 15 Multidimensional Gas Chromatography with Capillary Flow Technology and LTM-GC J Luong (et. al) Dow Chemical, R Mustacich (RVM) Published:Journal of Separation Science, ISSN , Volume 31, pp HPI examples 2D LTM/CFT/GC using Deans Switch and LTM s simultaneous/independent temperature programming of multiple LTM column modules

14 Environmental/Food Safety/Forensics Need for high through-put, especially for low margin samples, where analytical cycle times are a critical element in making a profit Key Sales Tools EN Ultra-Fast Total Petroleum Hydrocarbons (TPH) Analysis with Agilent Low Thermal Mass (LTM) GC and Simultaneous Dual- Tower Injection (Wei & Szelewski) - 9x faster TPH throughput using LTM - 18x faster TPH using LTM and dual simultaneous injection Pub No. TBA Polyaromatic Hydrocarbons (PAH) by LTM/GC/MS (~end Jan 09) - 2x faster PAH runs using LTM, even faster with Backflush - Enviro and Food Safety samples can be dirty. LTM columns cannot be trimmed (not Agilent, not Thermo ) - LTM uses guard columns and now Backflush/CFT backflush delivers multiple benefits for LTM analyses including. reduced potential for carryover, longer column life, shorter analysis time Page 16

15 Food/Flavor/Fragrance and Pharmaceutical Chiral Separations Chiral GC is most effective at low temperatures, yet complex samples usually require a broad temperature program to separate target compounds from background and to elute highly retained sample components. LTM/GC/MS uses a traditional column in the GC oven to separate target compounds, then heart-cut of target compounds to a chiral column in LTM module at a lower temp. optimal chiral separations are achieved while decreasing analysis cycle times and increasing chiral column lifetime. Pub No. TBA (~end Jan 09) Article (Fall 08) Chiral Separations by LTM/GC/MS - 2D LTM/GC/MS, simultaneous/independent temperature programming of GC and LTM column module(s) Multidimensional Gas Chromatography with Capillary Flow Technology and LTM-GC, J Luong (et. al) Dow Chemical,R Mustacich Published:Journal of Separation Science, ISSN , Volume 31, pp Examples 2D LTM/CFT/GC using Deans Switch and LTM s simultaneous/independent temperature programming of multiple LTM column modules Page 17

16 Productivity: CFT Backflush More analyses per unit time... Faster and more efficient separations Shorter analysis cycle time (time from injection to injection) Reduced requirement for sample preparation with consistently better results... Quantitative: accuracy, precision, detection limits, linear range Qualitative: response ratios, confirmatory retention times, library searches (eliminate false negatives and false positives) while using less operator time for each analysis. Less time performing maintenance Extensive computer control and data processing Simplified operator review/approval Page 18

17 Backflush Complete Column During GC Run Split Vent Trap Aux EPC 4 psi S/S Inlet MSD 25 psi After GC Run Split Vent Trap Column QuickSwap or 3- way Splitter Aux EPC 45 psi S/S Inlet MSD 1 psi Column QuickSwap or 3- way Splitter performance turbo recommended Page 19

18 Backflush Mid-Column (Analysis Mode) Split/Splitless Injection Port Pressure / Flow Controller Z ml/min very low flow; set against column backpressure, not short restrictor as with QuickSwap 7890A GC Vent Z ml/min Capillary Flow Technology Device Y+Z ml/min 5975C MSD EI mode Y ml/min 15-m HP-5ms (0.25mm id x0.25um) 15-m HP-5ms (0.25mm id x0.25um) PCT available Oct 08 Column 1 and 2 could be different phases and different dimensions Page 20

19 Backflush Mid-Column (Backflush Mode) Split/Splitless Injection Port Pressure / Flow Controller 7890A GC Vent Decrease inlet pressure during backflush Pressure Controlled Tee 5975C MSD EI mode 15-m HP-5ms (0.25mm id x0.25um) 15-m HP-5ms (0.25mm id x0.25um) Page 21

20 Backflush Mid-Column (Backflush Mode) Split/Splitless Injection Port Pressure / Flow Controller 7890A GC Vent Decrease inlet pressure during backflush Pressure Controlled Tee 5975C MSD EI mode Purged Ultimate Union To 2 nd Column & MSD From 1 st column 15-m HP-5ms (0.25mm id x0.25um) 15-m HP-5ms (0.25mm id x0.25um) From P control Page 22

21 Backflush Mid-Column (Timing Considerations) Sample - no backflush Sample - with backflush a b a = begin backflush (last peak exits column 1) b = increase flow 4 ml/min Solvent blank - no backflush Page 23

22 Comparison of Backflush Configurations QuickSwap (QS) Pressure Controlled Tee (PCT) 30 m column; restrictor (0.092mm*) Two 15 m columns PCT time Backflush (BF) BF flow 1 column vol MDS flow BF flow 1 column MSD flow savings Pressure (psi) (ml/min) (min) (ml/min) (ml/min) vol (min) (ml/min) (N x) * smallest restrictor => best QS case 4x faster & lower flow! T=300 C; head pressure =0.5psi Page 24

23 Backflush Impact on Data Quality Late eluters are more than just a timing problem Bake-out may push the limits of phase stability Matrix may not bake out well even at the upper limit of the column For high boiling matrices, backflush offers: Improved retention time precision Improved spectra quality Consistent detector response Increased column lifetime Page 25

24 GC/MS Industry Standard: Low Bleed Stationary Phases Low bleed means less background (and background ions) Low bleed column DB-35ms Better detection limits S/N =10 DB-35ms, 320 C 320 C DB-35ms Primary Ion Better spectra m/z--> Standard column S/N =3 DB DB-35 DB-35, 300 C 300 C 78 Primary Ion CLP Pesticides Analysis Column bleed = chemical noise 0 m/z--> Page 26

25 Typical GC/MS Separation Sequence Injection Filament ON after the solvent peak Separation and detection of the analytes Filament OFF after the last analyte peak and before bake-out In an effort to save the electron multiplier (EM), the operator is blind to the success of bakeout Bake-out may NOT be adequate for all samples This means the typical method will always have a potential for matrix carryover that the user does not expect. Page 27

26 Without Backflush: A Serious Problem Abundance 4.6e e e+07 4e e e e e+07 3e e e e e+07 2e e e e e+07 1e Time A: TIC: lettuce_blank.d\data.ms B: TIC: lettuce_blank3.d\data.ms Data provided by MSD user in Almeria, Spain After only 3 samples, the background is significantly higher (increase chemical noise is every spectrum) B A Overlay of two chromatograms of a blank extract injected BEFORE (A) and AFTER (B) three injections without backflush Page 28

27 Without Backflush: Changes in Retention Time Abundance 4.6e e e+07 4e e e e e+07 3e e e e e+07 2e e e e e+07 1e Time After only 3 samples A: TIC: lettuce_blank.d\data.ms B: TIC: lettuce_blank3.d\data.ms Data provided by MSD user in Almeria, Spain Highly retained matrix is altering the column selectivity and changing the retention time B A Overlay of two chromatograms of a blank extract injected BEFORE (A) and AFTER (B) three injections without backflush Page 29

28 Without Backflush: Increased Background Abundance 4.6e e e+07 4e e e e e+07 3e e e e e+07 2e e e e e+07 1e Time After only 3 samples A: TIC: lettuce_blank.d\data.ms B: TIC: lettuce_blank3.d\data.ms Data provided by MSD user in Almeria, Spain Sample matrix = chemical noise Increased background due to carryover of concentrated matrix Overlay of two chromatograms of a blank extract injected BEFORE (A) and AFTER (B) three injections without backflush B A Page 30

29 With Backflush: Consistent Retention Times and Baselines (No Increase in Spectral Noise) Abundance 4.6e e e+07 4e e e e e+07 3e e e e e+07 2e e e e e+07 1e Time TIC: lettuce_10_ppb.d\data.ms TIC: lettuce_100_ppb.d\data.ms TIC: lettuce_5_ppb.d\data.ms Data provided by user in Almeria, Spain Stable retention times and baseline... less chemical noise Overlay of three chromatograms of lettuce extract run with 2 min of back flush Page 31

30 What Real Value Does High Performance EPC Have If Matrix Carryover Destroys Rt Precision? N or m Runs with Backflushing Fish oil N or m. analysis Runs without Backflushing Retention times shift ~4-5 sec during 10 runs m in m in Page 32

31 Backflush with Purged Ultimate Union: Lipid Peroxidation Products in Blood 4-hydroxy-2,3-nonenal (HNE), an indicator of oxidative stress, and its metabolite, 1,4- dihydroxynonene (DHN) PCI with NH 3 App Note EN Late eluting peaks were quickly contaminating the source Page 33

32 Backflush with Purged Ultimate Union: Loss of Response without Backflush with backflush These were the first backflush results; the system is getting clearer without backflush App Note EN Page 34

33 Productivity Benefits of Backflush More samples per day per instrument Longer column life Lower operating costs Less frequent and faster GC & MSD maintenance Less chemical background More consistent retention times More consistent baselines Higher quality spectra (no increase in noise during analysis sequence) Higher quality quantitation (no increase in interfering ions during analysis sequence) Page 35

34 References for Backflush EN Capillary Flow Technology for GC/MS: Efficacy of the Simple Tee Configuration for Robust Analysis Using Rapid Backflushing for Matrix Elimination (Prest, Foucault, and Aubut, Aug 08) EN Screening for 430 Pesticide Residues in Traditional Chinese Medicine Using GC/MS: From Sample Preparation to Report Generation in One Hour (Luan, Xu, Sept08) EN Capillary Flow Technology for GC/MS: a Simple Tee Configuration for Analysis at trace Concentrations with Rapid Backflushing for Matrix Elimination (June 08, Prest) EN The Use of Automated Backflush on the 7890A/5975C GC- MS System EN Improved Forensic Toxicology Screening Using A GC/MS/NPD System with a 725-Compound DRS Database (Quimby, May08) EN, Replacing Multiple 50-Minute FPD/ELCD/SIM Analyses with One 15-Minute Full-Scan Analysis for 10x Productivity Gain (Meng/Szelewski, Nov07) Page 36

35 References for Backflush EN Analysis of Suspected Flavor and Fragrance Allergens in Cosmetics Using the 7890A GC and Capillary Column Backflush (March 2007) EN Direct Injection of Fish Oil for the GC-ECD Analysis of PCBs: Results Using a Dean Switch with Backflushing (Jan 2007) EN Rapid Forensic Toxicology Screening Using an Agilent 7890A/NPD/5975C/DRS GC/MSD System (Jan 2007) EN Improving Productivity and Extending Column Life with Backflush (Dec 2006) EN Simplified Backflush Using Agilent 6890 GC Post Run Command (June 2006) EN New Tools for Rapid Pesticide Analysis in High Matrix Samples (October 2004) Page 37

36 Productivity: Retention Time Locking More analyses per unit time... Faster and more efficient separations Shorter analysis cycle time (time from injection to injection) Reduced requirement for sample preparation with consistently better results... Quantitative: accuracy, precision, detection limits, linear range Qualitative: response ratios, confirmatory retention times, library searches (eliminate false negatives and false positives) while using less operator time for each analysis. Less time performing maintenance Extensive computer control and data processing Simplified operator review/approval Page 38

37 Retention Time Locking What is Retention Time Locking (RTL)? The ability to precisely match chromatographic retention times in any systems to those in another chromatographic system with the same nominal method and column. How is Retention Time Locking Done? By adjusting column head pressure via EPC using interactive ChemStation software. Page 39

38 Pesticides on Two Different GCs Before RTL Page 40

39 Pesticides on Two Different GCs After RTL Page 41

40 RTL Calibration - Done Once for a Given Method Make 5 runs at 5 different inlet pressures: target -20% target -10% target target +10% target +20% Determine RT of your target compound in each chromatogram Enter values into the RTL Software Page 42

41 Acquire RTLock Calibration Data.. Page 43

42 RTL Calibration Runs Are Collected Automatically Target Compound for RTL Dichlorvos Methyl chlorpyrifos Mirex 34 psi min 31 psi min 28 psi 25 psi min min 22 psi min Page 44

43 RTL Calibration Runs Are Collected Automatically And times can be edit manually Page 45

44 Page 46

45 RTL Re-Locking Procedure for Trimmed Column Original RTL Head pressure psi min. Trim front of column min Re-lock method New RTL Head pressure psi min. Page 47

46 Benefits of Locked Methods Faster method transfer & validation Faster startup after column maintenance Reduces / eliminates need to update RTs in calibration tables Easy set up of windows for SIM groups and MS/MS transitions Equivalent chromatography for all labs sharing a common method More efficient troubleshooting Easier review of data Faster identification of unknowns Page 48

47 Productivity: Trace Ion Detection More analyses per unit time... Faster and more efficient separations Shorter analysis cycle time (time from injection to injection) Reduced requirement for sample preparation with consistently better results... Quantitative: accuracy, precision, detection limits, linear range Qualitative: response ratios, confirmatory retention times, library searches (eliminate false negatives and false positives) while using less operator time for each analysis. Less time performing maintenance Extensive computer control and data processing Simplified operator review/approval Page 49

48 Trace Ion Detection Technology Proprietary algorithm Digital filtering Reduced noise level Improved peak shape Smoothes spikes on trace peaks Especially under-sampled peaks Improved library match Without Trace Ion Detection With Trace Ion Detection S/N = 53 S/N = 92 better detection at trace levels Page 50

49 Improve Library Match Quality Fenthion in strawberry extract Trace Ion Detection off Match Quality 30 Trace Ion Detection on Match Quality 92 Page 51

50 Trace Ion Detection Reduces False Negatives Page 52

51 Literature for Trace Ion Detection Technical Overview EN, The 5975C Series MSD: Method Optimization and Trace Ion Detection (Roushall/Prest, Mar 07) App Note EN, Replacing Multiple 50-Minute FPD/ELCD/SIM Analyses with One 15-Minute Full-Scan Analysis for 10x Productivity Gain (Meng/Szelewski, Nov07) Page 53

52 Productivity: Fast Electronic - SIM/Scan Mode More analyses per unit time... Faster and more efficient separations Shorter analysis cycle time (time from injection to injection) Reduced requirement for sample preparation with consistently better results... Quantitative: accuracy, precision, detection limits, linear range Qualitative: response ratios, confirmatory retention times, library searches (eliminate false negatives and false positives) while using less operator time for each analysis. Less time performing maintenance Extensive computer control and data processing Simplified operator review/approval Page 54

53 High Performance, Fast Electronics Higher percentage of time monitoring ions = more signal Higher data rate for narrow fast peaks = better area precision Page 55

54 High Performance Electronics for High Performance Synchronous SIM/Scan EN: Improving Productivity with Synchronous SIM/Scan Page 56

55 Fast Electronics: Synchronous SIM/Scan The best of both modes in a single run SIM = maximum sensitivity for target compounds Scan = best identification of non-targets (unknowns) High speed electronics is an Agilent strength Scan data points SIM data points Chromatographic peak time Scan time SIM time maximum information from a single run Tech Overview EN Page 57

56 Under-Sampled Peaks Acceptable for MS Acceptable precision can be achieved with fewer point per peak 6 samples/peak width for area; 8 samples/peak width for height Compromises to evaluate Affect of a slower data rate on quant precision Affect of shorter dwell time decrease SIM S/N Affect of faster scan rates decrease scan S/N For many applications... the decrease in precision and S/N are small compared to the benefits of SIM sensitivity and scan library searches Page 58

57 Literature for Synchronous SIM/Scan (slide 1 of 2) Tech Note EN, Improving Productivity with Synchronous SIM/Scan (Meng, May 05) Tech Note EN, Strategies for Developing Optimal Synchronous SIM-Scan Acquisition Methods AutoSIM/Scan Setup and Rapid SIM (Sept 06) App Note EN, Rapid Forensic Toxicology Screening Using an Agilent 7890A/NPD/5975C/DRS GC/MSD System (Quimby, Jan 07) App Note EN, Synchronous SIM/Scan Low-Level PAH Analysis Using the Agilent Technologies 6890/5975 inert GC/MSD (Szelewski, Nov 05) App Note EN, Determination of Trace Levels of Aromatic and Chlorinated Hydrocarbons in Water Using the G1888 Headspace Sample/6890N and 5975 inert MSD (Firor, Oct 05) Page 59

58 Literature for Synchronous SIM/Scan (slide 2 of 2) App Note EN, The Determination of Residual Solvents in Pharmaceuticals Using the Agilent G1888 Headspace/6890N GC/5975 inert MSD system (Firor/Gudat, June 05) App Note EN, The Determination of Extractables and Leachables in Pharmaceutical Packaging Material Using Headspace GC/MS (Gudat/Firor, Aug 06) App Note EN, Screening for Hazardous Chemicals in Homeland Security and Environmental Samples Using a GC/MS/ECD/FPD with a 731 Compound DRS Database (Quimby/Szelewski, Feb 06) App Note EN, Identifying Pesticides with Full Scan, SIM, uecd, and FPD from a Single Injection (Meng/Quimby, July 05) Tech Note EN (AutoSIM), New Approaches to the Development of GC/MS Selected Ion Monitoring Acquisition and Quantitation Methods (Prest/Peterson, Nov 01) Page 60

59 Productivity Method Translator More analyses per unit time... Faster and more efficient separations Shorter analysis cycle time (time from injection to injection) Reduced requirement for sample preparation with consistently better results... Quantitative: accuracy, precision, MDL, linearity, consistent sensitivity Qualitative: response ratios, confirmatory retention times, library searches (eliminate false negatives and false positives) while using less operator time for each analysis. Less time performing maintenance Extensive computer control and data processing Simplified operator review/approval Page 61

60 What is Method Translation? MTL is a freeware program that determines new method conditions such that relative elution order is constant, and relative run time is known. MTL works: g when changing column outlet pressure (e.g., from FID to MSD) g when changing carrier gas type (e.g., from He to H 2 ) or flow rate g when changing column dimensions (same phase, different diameter, length, or phase ratio) Page 62

61 Method Translator Screen capture showing the Method Translation (MTL) Software data entry used in a 4X speed gain translation. Page 63

62 Method Translations to 100 um Column Column id. Speed Gain Length (m) I.D. (µm) D.F. (µm) Inlet P (psig) Outlet P (psia) Flow (ml/min) Init Temp ( C) Init Hold (min) Ramp 1 ( C/min) Final Temp1 ( C) Final Time 1 (min) Ramp 2 ( C/min) Final Temp 2 ( C) Final Time 2 (min) Ramp 3 ( C/min) Final Temp 3 ( C) Final Time 3 (min) 250 µm (X1) µm (X2) µm (X3) µm (X4) Page 64

63 Method Translations to 15 m Column Column Length (m) Speed Gain Part Number I.D. (µm) D.F. (µm) Inlet P (psig) Outlet P (psia) Flow (ml/min) Init Temp ( C) Init Hold (min) Ramp 1 ( C/min) Final Temp1 ( C) Final Time 1 (min) Ramp 2 ( C/min) Final Temp 2 ( C) Final Time 2 (min) Ramp 3 ( C/min) Final Temp 3 ( C) Final Time 3 (min) 30 m (X1) 19091S m (X2.5) 19091S m (X4) 19091S Page 65

64 Productivity Triple Axis Detector with Gain Normalization and EM Saver More analyses per unit time... Faster and more efficient separations Shorter analysis cycle time (time from injection to injection) Reduced requirement for sample preparation with consistently better results... Quantitative: accuracy, precision, MDL, linearity, consistent sensitivity Qualitative: response ratios, confirmatory retention times, library searches (eliminate false negatives and false positives) while using less operator time for each analysis. Less time performing maintenance Extensive computer control and data processing Simplified operator review/approval Page 66

65 Conventional Off-Axis Detector hyperbolic quartz transmission quadrupole analyzer ion beam Although not directly striking the HED- EM, excited helium neutrals can ionize other molecules and create secondary particles from collisions with surfaces (sputtered ions from surface contamination, ions from the surface, photons and electrons) high energy dynode (high voltage pulls the ions away from the neutrals) electron multiplier energetic neutrals Page 67

66 Triple-Axis Detector With a combination of three axes and appropriate shielding, noise from metastable helium, photons, etc. can be reduced to a minimum Offset Z This aperture is larger than the off-axis detector which means more ions and energetic neutrals pass to the detector Y ion beam X shield blocking secondary ions formed by metastable helium after the analyzer Page 68

67 Triple-Axis Detector: Higher Signal Lower MDL Dashed line show 95% confidence limits Increased slope = higher sensitivity Lower detection limits! Tech Overview EN fg Page 69

68 Triple Channel EM Exit of the triple channels Triple channels improve signal amplification Lower initial EM voltage required Triple channels increase life Lower cost of operation Collector removed to show exit passages Collector Page 70

69 Tuning Optimization of Multiple Components Tuning ion transmission characteristics Optimize potentials on lens and analyzer Effects the relative abundance of ions WITHIN a spectrum For example, the intensity ratio of m/z 100 to 200 or 100 to 300 Effects the absolute number of ions entering the EM Improves spectra comparisons between instruments US EPA standards made this a critical issue in many areas of the world Gain Normalization of ion amplification (EM only) Effect the ion count or absolute abundance of each ion Does NOT affect the number of ions entering the EM Changes the amplification of charge passing through the EM Page 71

70 Gain Normalized EM Adjustment for Sensitivity Ion source Quadrupole High Energy Dynode (10kV) i Electron Multiplier (EM) EMV EMV: 1kV to 3kV I I i GAIN Tuning EM voltage changes sensitivity for all ions -- NOT the relative abundances Amplification of signal now, user-selectable!!! Tech Overview EN Page 72

71 Sensitivity Limitation of ATUNE + nv During aging, the same EMV setting will not give the same signal! New detector S ig nal vs E M V Aged detector Page Sig n al ATUNE+400V ATUNE + 400V ATUNE (new) ATUNE (aged) Tech Overview EN Decreasing signal with age As signal decreases, it appears the MS has lost sensitivity In reality, the MS was OK, but the EMV was too low + 600V EM V

72 Sensitivity Advantage of Gain Normalization During aging, the same GAIN setting will give the same signal! S ig n al v s G AIN Aged New Signal With Gain Normalization, the operation does not have to think about aging, sensitivity is the same for a new or aged EM at any Gain setting simple! G ain Factor as G A IN x 10^ 5 Tech Overview EN Page 74

73 ATune + nv versus Gain Normalized Methods New Aged 1000 GAIN Tune ATUNE+ n V 1000 New triple channel EM ages more slowly GAIN Tune ATUNE+ n V Consistent sensitivity over the life of the electron multiplier! Consistent sensitivity from MSD to MSD and lab to lab! Tech Overview EN Page 75

74 Benefits of Gain Normalization (EM Optimization) New Option: GAIN Normalized methods Gain Factors are set & saved as a method parameter! Finer Gain Adjustment for better optimization Greater reproducibility over time Greater consistency -for any instrument, or -between a group of instruments No linearity errors with new EM Easier tuning & system troubleshooting Six excellent reasons to use Gain Factors!! Page 76

75 Literature for Gain Normalization Technical Overview EN, Enhancements to Gain Normalized Instrument Tuning: Understanding the Benefits and Features Technical Overview EN, The Triple-Axis Detector: Attributes and Operating Advice Technical Overview EN, The 5975C Series MSD: Normalized Instrument Tuning Page 77

76 EM Saver When too many ions are striking the EM, the response saturates and the overload can damage the EM EM Saver and fast electronics quickly alters the analyzer voltages to decrease ion transmission A simple concept with real benefits to EM life Highly concentrated peaks cannot damage the Agilent EM Page 78

77 Productivity Hydrogen Carrier Gas More analyses per unit time... Faster and more efficient separations Shorter analysis cycle time (time from injection to injection) Reduced requirement for sample preparation with consistently better results... Quantitative: accuracy, precision, detection limits, linear range Qualitative: response ratios, confirmatory retention times, library searches (eliminate false negatives and false positives) while using less operator time for each analysis. Less time performing maintenance Extensive computer control and data processing Simplified operator review/approval Page 79

78 Helium Shortage Means Higher Operating Costs Pg 31 October 8, 2007 Page 80

79 H 2 Requires Different Setup and Extra Care Lower column head pressure experienced with H 2 H 2 is upwards of 100% faster than with helium; the column internal diameter may need to decrease to have optimal pressure control There is a downloadable Method Translation Software to guide the customer H 2 is reactive towards some compounds. This can be an advantage or a disadvantage depending on the application Sometimes very reactive compounds can be measured as their hydrogenated counterparts Diffusion is much faster in H 2 The van Deemter curve will shift and the HETP (height equivalent of a theoretical plate; column efficiency) will be different compared to helium GC resolution can be improved under optimal conditions H 2 is explosive Auto-ignition temperature is 400ºC and the LEL/UEL are very wide Special cautions may be required for safety Hydrogen generators can greatly reduce safety concerns Page 81

80 Agilent Tests for Hydrogen Safety Page 82

81 Hydrogen Generators Make the Cost Very Low and Ensure High Quality Gas Page 83

82 Literature for Hydrogen Carrier Gas Manual G , 5975C MSD Hydrogen Safety (Oct 05) Technical Overview EN, A Complete Solution for Chlorinated Pesticides and Herbicides Using DB-35ms and DB- XLB Columns (hydrogen and helium comparison) (Dec 01) Page 84

83 Productivity Deconvolution Reporting Software More analyses per unit time... Faster and more efficient separations Shorter analysis cycle time (time from injection to injection) Reduced requirement for sample preparation with consistently better results... Quantitative: accuracy, precision, detection limits, linear range Qualitative: response ratios, confirmatory retention times, library searches (eliminate false negatives and false positives) while using less operator time for each analysis. Less time performing maintenance Extensive computer control and data processing Simplified operator review/approval Page 85

84 What is Deconvolution Reporting Software (DRS)? A second opportunity for accurate result without another analysis A post-run calculation based on the NIST algorithm A solution to the unpredictable matrix interferences DRS makes optimal use of both GC and MS information Combines peak profiles and spectra Extract pure component information from the coeluting peaks Uses RTL database spectra to filter analytes of interest from vast number of matrix peaks Confirms against complete NIST library spectra ChemStation QEdit summary of standard and deconvoluted data Page 86

85 How Does AMDIS Work? Uses Difference in Spectra, Retention Time and Peak Shape Peak detected with Trace Ion Detection TIC TIC & Spectrum Component 1 Component 2 Deconvoluted peaks and spectra Mathematical Separation matrix Component 3 interference Deconvolution Some m/z values pure Some m/z values mixed target m/z Page 87

86 Pulling a Useable Spectrum Out of a Mess Analyte ions are buried in the matrix ions!! Cleaned analyte spectrum is easy to match! Page 88

87 What is the Agilent DRS? ChemStation for Quant + AMDIS 32 Deconvolute and ID + CONSOLIDATED QUANTITATIVE and QUALITATIVE HTML REPORT NIST Confirm Page 89

88 Reduced Errors and Less Faster Results Summary of Pesticide Analysis in 17 Surface Water Samples Targets Found False Positives Processing Time *CDFA 37 1 ~ 8 hours Agilent DRS Same additional 0 32 minutes *CDFA is the California Department of Food and Agriculture Data files courtesy of Dr. Mark Lee and Steve Siegel Save about 7.5 hours to do other jobs Page 90

89 QEdit Summary of Qual and Quant (DRS A.04) Overlay of target(s) and Deconvoluted ion plots Target ion plot Deconvoluted ion plot Spectral review: Before AMDIS After AMDIS AMDIS Library Hits X = MSD A = AMDIS Areas & amounts from target ion and Deconvoluted ion Page 91

90 Summary Report with MSD and AMDIS Results partial report Page 92

91 Graphics Report MSD and AMDIS 5- ion overlay Raw, deconvoluted and library spectra MSD and AMDIS areas and amounts Page 93

92 Supporting Literature for DRS (slide 1 of 3) App Note EN, Improved Forensic Toxicology Screening Using a GC/MS/NPD System with a 725-Compound DRS Database (Quimby, May08) Capillary Flow Technology for solvent vent and NPD Backflush to shorten analysis time and increase column lifetime Synchronous SIM/scan (max sensitivity and max information) Trace Ion Detection to reduce noise before DRS Next generation of DRS with AMDIS results in QEdit and Agilent database Real blood extracts from NMS Lab, Willow Grove, PA, USA App Note EN, Replacing Multiple 50-Minute FPD/ELCD/SIM Analyses with One 15-Minute Full-Scan Analysis for 10x Productivity Gain (Meng/Szelewski, Nov07) Capillary Flow Technology for multiple detectors (3-way splitter) Backflush to shorten analysis time and increase column lifetime Trace Ion Detection to reduce noise before DRS Next generation of DRS with AMDIS results in QEdit and Agilent database Real results from US Food and Drug Administration/Center for Food Safety and Applied Nutrition (FDA/CFSAN) Page 94

93 Supporting Literature for DRS (slide 2 of 3) App Note EN, Screening for Pesticides in Food Using the Japanese Positive List Pesticide Method: Benefits of Using GC/MS with Deconvolution Reporting Software and a Retention Time Locked Mass Spectral Database (Wylie, Sept07) App Note EN, Reducing Analysis Time Using GC/MSD and Deconvolution Reporting Software (May07) App Note EN, Rapid Forensic Toxicology Screening Using an Agilent 7890A/NPD/5975/DRS GC/MSD System (Quimby, Jan07) App Note EN, Screening for 171 Volatile Organic Air Pollutants Using GC/MS with Deconvolution Reporting Software and a New Indoor Air Toxics Library (Wylie, Aug06) App Note EN, Screening for 926 Pesticides and Endocrine Disruptors by GC/Ms with Deconvolution Reporting Software and a New Pesticide Library (Wylie, Apr06) Page 95

94 Supporting Literature for DRS (slide 3 of 3) App Note EN, Screening for Hazardous Chemicals in Homeland Security and Environmental Samples Using a GC/MS/ECD/FPD with a 731 Compound DRS Database (Quimby, Szelewski, Feb06) App Note EN, New Tools for Rapid Pesticide Analysis in High Matrix Samples, (Szelewski, Quimby, Oct04) App Note EN, A Blind Study of Pesticide Residues in Spiked and Unspiked Fruit Extracts Using Deconvolution Reporting Software App Note EN, Comprehensive Pesticide Screening by GC/MSD using Deconvolution Reporting Software (Wylie/Szelewski/Meng, May04) Page 96

95 RTL is more flexible now GC/MSD user can manually edit these times Page 97

96 Largest Selection of Industry Specific Retention Time Locked Databases Product No. RTL DBL Description Compounds G1671AA Hazardous Chemical 730 G1672AA Pesticide 926 G1673AA Indoor Air Toxics 171 G1674AA Forensic Toxicology 723 G1675AA JPN Positive List Pesticide 431 G1676AA Fiehn Metabolomics 665 G1677AA Environmental Semi-voas 273 Library include GC method details, Getting Started manual, application notes, and HELP files Free Volatile Organic Compounds 65 Free PCB Congeners 209 Free Forensic Toxicology 277 Free Fatty Acid Methyl Ester 37 Free Flavors 409 Free Organotin Derivatives Methyl, Ethyl, Pentyl modify a library to meet your need or create your own Page 98

97 Supporting Literature for RTL (slide 1 of 4) App Note EN, Semivolatiles Retention Time Locked (RTL) Deconvolution Databases for Agilent GC/MSD Systems (Szelewski, Feb 08) G1677AA App Note EN, Replacing Multiple 50-Minute FPD/ELCD/SIM Analyses with One 15-Minute Full-Scan Analysis for 10x Productivity Gain (Meng/Szelewski, Nov07) G1672AA App Note EN, Screening for Pesticides in Food Using the Japanese Positive List Pesticide Method: Benefits of Using GC/MS with Deconvolution Reporting Software and a Retention Time Locked Mass Spectral Database (Wylie, Sept07) G1675AA App Note EN, Reducing Analysis Time Using GC/MSD and Deconvolution Reporting Software (May07) App Note EN, Rapid Forensic Toxicology Screening Using an Agilent 7890A/NPD/5975/DRS GC/MSD System (Quimby, Jan07) free DBL Page 99

98 Supporting Literature for RTL (slide 2 of 4) App Note EN, Screening for 171 Volatile Organic Air Pollutants Using GC/MS with Deconvolution Reporting Software and a New Indoor Air Toxics Library (Wylie, Aug06) G1673AA App Note EN, Screening for 926 Pesticides and Endocrine Disruptors by GC/Ms with Deconvolution Reporting Software and a New Pesticide Library (Wylie, Apr06) G1672AA App Note EN, Screening for Hazardous Chemicals in Homeland Security and Environmental Samples Using a GC/MS/ECD/FPD with a 731 Compound DRS Database (Quimby/Szelewski, Feb06) G1671AA App Note EN, Developing an emethod for the Analysis of Volatile Organic Compounds in Water Using Purge and Trap/GC with Agilent s New 5973 inert Mass Spectrometer (Wylie, Jul 05) App Note EN, Determination of Polybrominated Diphenyl Ethers in Polymeric Materials Using the 6890 GC/5973N inert MSD with Electron Impact Ionization (Tu/Prest, Apr05) Page 100

99 Supporting Literature for RTL (slide 3 of 4) App Note EN, New Tools for Rapid Pesticide Analysis in High Matrix Samples, (Szelewski/Quimby, Oct04) App Note EN, A Blind Study of Pesticide Residues in Spiked and Unspiked Fruit Extracts Using Deconvolution Reporting Software (Sandy, Oct04) Tech Overview EN, Building and Editing RTL Screener/Quant Databases and Libraries (Szelewski/Weiner/Meng, June04) App Note EN, Comprehensive Pesticide Screening by GC/MSD using Deconvolution Reporting Software (Wylie/Szelewski/Meng, May04) App Note EN, Improving the Analysis of Fatty Acid Methyl Esters Using Retention Time Locked Methods and Retention Time Databases (David/Sandra/Wylie, Sept 03) App Note EN, Improving the Analysis of Organtin Compounds Using Retention Time Locked Methods and Retention Time Databases (David/Sandra/Wylie, Apr03) Page 101

100 Supporting Literature for RTL (slide 4 of 4) App Note EN, Solid-phase Extraction and Retention Time Locked GC/MS Analysis of Selected Polycyclic Aromatic Hydrocarbons (PAHs) (Prest, July 02) App Note EN, Retention Time Locked GC-MS Analysis of Phenols (Reese/Prest, Apr02) App Note EN, Identification and Quantitation of Pesticides in the Partper-Trillion Range Using Retention Time Locking and GC/MS (Meng, Nov 01) Tech Note EN (AutoSIM), New Approaches to the Development of GC/MS Selected Ion Monitoring Acquisition and Quantitation Methods (Prest/Peterson, Nov 01) App Note EN, A New Approach to the Analysis of Phthalate Esters by GC/MS (George/Prest, Mar 01) App Note EN, Ambient Headspace GC and GC-MSD Analysis of Non- Polar Volatiles in Water (Szelewski/Quimby, Feb 00) App Note E, Retention Time Locking: Creating Custom Retention Time Locked Screener Libraries (Weiner/Prest, Dec 99 ) Page 102

Useful GC/MS Sensitivity for Improved Environmental Analyses. GC/MS Agilent Restricted

Useful GC/MS Sensitivity for Improved Environmental Analyses. GC/MS Agilent Restricted Useful Sensitivity for Improved Environmental Analyses Page 1 Definitions Sensitivity Analytical definition: slope of the plot of amount of analyte (x-axis) versus signal response (y-axis) Commonly used

More information

Identifying Pesticides with Full Scan, SIM, µecd, and FPD from a Single Injection Application

Identifying Pesticides with Full Scan, SIM, µecd, and FPD from a Single Injection Application Identifying Pesticides with Full Scan, SIM, µecd, and FPD from a Single Injection Application Food Safety, Environmental Authors Chin-Kai Meng and Bruce Quimby Agilent Technologies, Inc. 2850 Centerville

More information

Highly Sensitive and Rugged GC/MS/MS Tool

Highly Sensitive and Rugged GC/MS/MS Tool Highly Sensitive and Rugged GC/MS/MS Tool For Pesticide Multiresidue Analysis in Food Samples Agilent 7 Series Triple Quadrupole GC/MS. The world s first MS/MS designed specifically for GC Analysis Introduction

More information

New Approaches to the Development of GC/MS Selected Ion Monitoring Acquisition and Quantitation Methods Technique/Technology

New Approaches to the Development of GC/MS Selected Ion Monitoring Acquisition and Quantitation Methods Technique/Technology New Approaches to the Development of GC/MS Selected Ion Monitoring Acquisition and Quantitation Methods Technique/Technology Gas Chromatography/Mass Spectrometry Author Harry Prest 1601 California Avenue

More information

Cerno Bioscience MassWorks: Acquiring Calibration Data on Agilent GC/MSDs

Cerno Bioscience MassWorks: Acquiring Calibration Data on Agilent GC/MSDs Cerno Bioscience MassWorks: Acquiring Calibration Data on Agilent GC/MSDs Application Note Author Harry Prest, Ph.D. Senior Chemist in GC-MS Agilent Technologies, Inc. 5301 Stevens Creek Blvd Santa Clara,

More information

Introducing the Agilent 7000A QQQ-MS for GC Sunil Kulkarni Product Specialist Agilent Technologies

Introducing the Agilent 7000A QQQ-MS for GC Sunil Kulkarni Product Specialist Agilent Technologies Introducing the Agilent 7000A QQQ-MS for GC Sunil Kulkarni Product Specialist Agilent Technologies Page 1 Agilent GC/MS Portfolio Smallest footprint, single GC column 5975VL with 6850GC Industry leading

More information

Analysis of Trace (mg/kg) Thiophene in Benzene Using Two-Dimensional Gas Chromatography and Flame Ionization Detection Application

Analysis of Trace (mg/kg) Thiophene in Benzene Using Two-Dimensional Gas Chromatography and Flame Ionization Detection Application Analysis of Trace (mg/kg) Thiophene in Using Two-Dimensional Gas Chromatography and Flame Ionization Detection Application Petrochemical Authors James D. McCurry and Bruce D. Quimby Agilent Technologies

More information

Agilent s New 7000B Quadrupole GC/MS/MS:

Agilent s New 7000B Quadrupole GC/MS/MS: Agilent s New 7000B Quadrupole GC/MS/MS: Evolving technology for higher performance tools Terry L. Sheehan, Ph.D. GC/MS/MS Product Manager Agilent Technologies Santa Clara, CA Page 1 Triple Quadrupole

More information

The Importance of Area and Retention Time Precision in Gas Chromatography Technical Note

The Importance of Area and Retention Time Precision in Gas Chromatography Technical Note The Importance of Area and Retention Time Precision in Gas Chromatography Technical Note Abstract Area and retention time are the two primary measurements in gas chromatography. The precision with which

More information

Practical Faster GC Applications with High-Efficiency GC Columns and Method Translation Software

Practical Faster GC Applications with High-Efficiency GC Columns and Method Translation Software Practical Faster GC Applications with High-Efficiency GC Columns and Method Translation Software High Efficiency GC Columns Page 1 Variables for Shortening Run Times Stationary Phase Shorten Column Length

More information

Agilent 5977A Series GC/MSD System

Agilent 5977A Series GC/MSD System Agilent 5977A Series GC/MSD System Data Sheet 5977A GC/MSD Overview The Agilent 5977A Series GC/MSD builds on a 45-year tradition of leadership and innovation, bringing together the technologies of the

More information

Screening for Water Pollutants With the Agilent SureTarget GC/MSD Water Pollutants Screener, SureTarget Workflow, and Customized Reporting

Screening for Water Pollutants With the Agilent SureTarget GC/MSD Water Pollutants Screener, SureTarget Workflow, and Customized Reporting Screening for Water Pollutants With the Agilent SureTarget GC/MSD Water Pollutants Screener, SureTarget Workflow, and Customized Reporting Application Note Authors Angela Smith Henry and Bruce Quimby Agilent

More information

Improved Forensic Toxicology Screening Using A GC/MS/NPD System with a 725-Compound DRS Database. Application. Author. Introduction.

Improved Forensic Toxicology Screening Using A GC/MS/NPD System with a 725-Compound DRS Database. Application. Author. Introduction. Improved Forensic Toxicology Screening Using A GC/MS/NPD System with a 725-Compound DRS Database Application Forensic Toxicology Author Bruce Quimby Agilent Technologies 2850 Centerville Road Wilmington,

More information

Fast and Accurate EPA 8270 Quantitation Using Deconvolution

Fast and Accurate EPA 8270 Quantitation Using Deconvolution Fast and Accurate EPA 8270 Quantitation Using Deconvolution Application Note Environmental Authors Mike Szelewski and Chinkai Meng Agilent Technologies, Inc. 2850 Centerville Road Wilmington, DE 19808

More information

Fast USEPA 8270 Semivolatiles Analysis Using the 6890/5973 inert GC/MSD with Performance Electronics Application

Fast USEPA 8270 Semivolatiles Analysis Using the 6890/5973 inert GC/MSD with Performance Electronics Application Fast USEPA 8270 Semivolatiles Analysis Using the 6890/5973 inert GC/MSD with Performance Electronics Application Environmental Analysis Author Mike Szelewski Agilent Technologies, Inc. 2850 Centerville

More information

Enhanced Sensitivity for Biomarker Characterization in Petroleum Using Triple Quadrupole GC/MS and Backflushing

Enhanced Sensitivity for Biomarker Characterization in Petroleum Using Triple Quadrupole GC/MS and Backflushing Enhanced Sensitivity for Biomarker Characterization in Petroleum Using Triple Quadrupole GC/MS and Backflushing Application Note Environmental Authors Melissa Churley Agilent Technologies, Inc. 5310 Stevens

More information

Practical Faster GC Applications with High-Efficiency GC Columns and Method Translation Software

Practical Faster GC Applications with High-Efficiency GC Columns and Method Translation Software Practical Faster GC Applications with High-Efficiency GC Columns and Method Translation Software GC Columns and Consumables Mark Sinnott Application Engineer January 8 th, 2008 Page 1 Questions to Ask

More information

Multi-residue GC-MS analysis. Richard Fussell CSL York, UK

Multi-residue GC-MS analysis. Richard Fussell CSL York, UK Multi-residue GC-MS analysis Richard Fussell CSL York, UK e-mail: r.fussell@csl.gov.uk Outline of Presentation Background Gas Chromatography Mass Spectrometry - Options Capabilities and Applications Summary

More information

USP<467> residual solvents

USP<467> residual solvents Application Note Pharmaceuticals USP residual solvents Applying the Agilent 977A MSD with the Agilent 797A headspace sampler and Agilent 7890B GC Authors Roger L. Firor and Mike Szelewski Agilent Technologies,

More information

Workflow Using Hyphenated Mass Spectrometry Techniques

Workflow Using Hyphenated Mass Spectrometry Techniques Pesticide Analysis Workflow Using Hyphenated Mass Spectrometry Techniques Chinkai (Kai) Meng, Ph.D. Senior Applications Chemist Wilmington, Delaware USA chin_meng@agilent.com com February 12, 2009 Page

More information

U.S. EPA Method 8270 for multicomponent analyte determination

U.S. EPA Method 8270 for multicomponent analyte determination ENVIRONMENTAL application note U.S. EPA Method 8270 for multicomponent analyte determination Elaine A. LeMoine and Herman Hoberecht Introduction Multicomponent analytes are compounds that yield several

More information

Expectations for GC-MS Lab

Expectations for GC-MS Lab Expectations for GC-MS Lab Since this is the first year for GC-MS to be used in Dr. Lamp s CHEM 322, the lab experiment is somewhat unstructured. As you move through the experiment, I expect that you will

More information

Author. Abstract. Introduction

Author. Abstract. Introduction Improved Performance for the Analysis of Aromatics in Gasoline by ASTM Method D5769 Using the Agilent 5973 inert Gas Chromatography/Mass Spectrometry System Application Author James D. McCurry Agilent

More information

Understanding Gas Chromatography

Understanding Gas Chromatography Understanding Gas Chromatography What is Really Going on Inside the Box? Simon Jones GC Applications Engineer Page 1 Group/Presentation Title Month ##, 200X ?? K? Page 2 Typical GC System Gas supply Injector

More information

brochure brief 5973Network Mass Selective Detector General Description and Configurations

brochure brief 5973Network Mass Selective Detector General Description and Configurations brochure brief 5973Network Mass Selective Detector This publication provides general technical information about the 5973Network MSDs to accompany the specifications and brochure. The MSD series was originally

More information

Introduction to Capillary GC

Introduction to Capillary GC ?? Kβ? Page 1 Typical GC System Gas supply Injector Detector Data handling GAS Column Oven Page 2 CARRIER GAS Carries the solutes down the column Selection and velocity influences efficiency and retention

More information

Analyze Hydrocarbon Impurities in 1,3-Butadiene with an Agilent J&W GS-Alumina PT Column

Analyze Hydrocarbon Impurities in 1,3-Butadiene with an Agilent J&W GS-Alumina PT Column Analyze Hydrocarbon Impurities in,3-butadiene with an Agilent J&W GS-Alua PT Column Application Note Energy and Chemicals Authors Yun Zou and Chunxiao Wang Agilent Technologies Shanghai Ltd Abstract The

More information

Pittcon P

Pittcon P PO-CON1701E 76% Increase in Throughput for Determination of Semi-Volatiles Using Narrow-Bore GC Columns and Rapid Data Acquisition with a Highly Sensitive Quadrupole GCMS System Pittcon 2017 1440-14P Brahm

More information

Application Note # Performance of Method 8270 Using Hydrogen Carrier Gas on SCION Bruker SCION GC-MS

Application Note # Performance of Method 8270 Using Hydrogen Carrier Gas on SCION Bruker SCION GC-MS Application Note #1820230 Performance of Method 8270 Using Hydrogen Carrier Gas on SCION Bruker SCION GC-MS GC-MS Introduction USEPA Method 8270 [1] for semivolatiles is is used by by laboratories to measure

More information

Secrets of GC Column Dimensions

Secrets of GC Column Dimensions Secrets of GC Column Dimensions GC Columns and Consumables Simon Jones Application Engineer May 20, 2008 Slide 1 Secrets of GC Column Dimensions Do I have the right column phase? Resolution Equation Changes

More information

All Ions MS/MS: Targeted Screening and Quantitation Using Agilent TOF and Q-TOF LC/MS Systems

All Ions MS/MS: Targeted Screening and Quantitation Using Agilent TOF and Q-TOF LC/MS Systems All Ions MS/MS: Targeted Screening and Quantitation Using Agilent TOF and Q-TOF LC/MS Systems Technical Overview Introduction All Ions MS/MS is a technique that is available for Agilent high resolution

More information

METHOD 3600C CLEANUP

METHOD 3600C CLEANUP METHOD 3600C CLEANUP 1.0 SCOPE AND APPLICATION 1.1 Method 3600 provides general guidance on selection of cleanup methods that are appropriate for the target analytes of interest. Cleanup methods are applied

More information

GAS CHROMATOGRAPHY MASS SPECTROMETRY. Pre-Lab Questions

GAS CHROMATOGRAPHY MASS SPECTROMETRY. Pre-Lab Questions GAS CHROMATOGRAPHY MASS SPECTROMETRY Pre-Lab Questions Questions to be answered before doing the experiment. The answers are due at the beginning of each experiment without exception (the questions are

More information

Multi-residue analysis of pesticides by GC-HRMS

Multi-residue analysis of pesticides by GC-HRMS An Executive Summary Multi-residue analysis of pesticides by GC-HRMS Dr. Hans Mol is senior scientist at RIKILT- Wageningen UR Introduction Regulatory authorities throughout the world set and enforce strict

More information

METHOD 3600B CLEANUP

METHOD 3600B CLEANUP METHOD 3600B CLEANUP 1.0 SCOPE AND APPLICATION 1.1 Method 3600 provides general guidance on selection of cleanup methods that are appropriate for the target analytes of interest. Cleanup methods are applied

More information

Making Sense of Differences in LCMS Data: Integrated Tools

Making Sense of Differences in LCMS Data: Integrated Tools Making Sense of Differences in LCMS Data: Integrated Tools David A. Weil Agilent Technologies MassHunter Overview Page 1 March 2008 How Clean is our Water?... Page 2 Chemical Residue Analysis.... From

More information

Agilent ESI and APCI sources: for polar to non-polar compounds

Agilent ESI and APCI sources: for polar to non-polar compounds 1 Agilent 6400 Series Triple Quadrupole Users Workshop 1 Agilent ESI and APCI sources: for polar to non-polar compounds Nebulizer Pressure Corona current Nebulizer Pressure Vaporizer Vcap Vcap Drying Gas

More information

Analysis of TO-15/TO-17 air toxics in urban air using TD GC/TOF MS and automated compound identification software

Analysis of TO-15/TO-17 air toxics in urban air using TD GC/TOF MS and automated compound identification software Analysis of TO-15/TO-17 air toxics in urban air using TD GC/TOF MS and automated compound identification software NEMC, Washington D.C. August 6 th 2012 Nicola Watson Environmental Specialist Markes International

More information

Uncontrolled Copy. SOP-060 Chromatography, Tune Evaluation and Troubleshooting. Table of Contents. 1. Principle... 3

Uncontrolled Copy. SOP-060 Chromatography, Tune Evaluation and Troubleshooting. Table of Contents. 1. Principle... 3 Table of Contents 1. Principle... 3 2. Mass Spectrometer Evaluation... 3 3. GC NPD Evaluation... 5 4. Acid Neutral test injection evaluation (GC/MS/FID)... 6 5. Discrepancies... 6 6. Troubleshooting...

More information

GAS CHROMATOGRAPHY (GC)

GAS CHROMATOGRAPHY (GC) GAS CHROMATOGRAPHY (GC) Pre-Lab Questions Questions are to be answered before the beginning of the laboratory. The answers are due at the beginning of each experiment (the questions are for credit and

More information

Static Headspace Blood Alcohol Analysis with the G1888 Network Headspace Sampler Application

Static Headspace Blood Alcohol Analysis with the G1888 Network Headspace Sampler Application Static Headspace Blood Alcohol Analysis with the G Network Headspace Sampler Application Forensics Author Roger L. Firor and Chin-Kai Meng Agilent Technologies, Inc. 0 Centerville Road Wilmington, DE 90-0

More information

2401 Gas (liquid) Chromatography

2401 Gas (liquid) Chromatography 2401 Gas (liquid) Chromatography Chromatography Scheme Gas chromatography - specifically gas-liquid chromatography - involves a sample being vaporized and injected onto the head of the chromatographic

More information

Analysis of Natural Oils and Extracts Using the Low Thermal Mass LTM Series II System

Analysis of Natural Oils and Extracts Using the Low Thermal Mass LTM Series II System Analysis of Natural Oils and Extracts Using the Low Thermal Mass LTM Series II System Application Note Author Roger L. Firor Agilent Technologies, Inc. 2850 Centerville Rd Wilmington, DE 19808 Abstract

More information

Identification and Quantitation of PCB Aroclor Mixtures in a Single Run Using the Agilent 7000B Triple Quadrupole GC/MS

Identification and Quantitation of PCB Aroclor Mixtures in a Single Run Using the Agilent 7000B Triple Quadrupole GC/MS Identification and Quantitation of PCB Aroclor Mixtures in a Single Run Using the Agilent 7B Triple Quadrupole GC/MS Application Note Authors Dale R. Walker and Fred Feyerherm Agilent Technologies, Inc.

More information

Selection of a Capillary GC Column

Selection of a Capillary GC Column Selection of a Capillary GC Column Mark Sinnott Application Engineer March 13, 2008 Page 1 Typical Gas Chromatographic System Mol-Sieve Traps Fixed Restrictors Regulators Injection Port Detector Electrometer

More information

Application Note. Gas Chromatography/Mass Spectrometry/Food Safety. Abstract. Authors

Application Note. Gas Chromatography/Mass Spectrometry/Food Safety. Abstract. Authors Trace-Level Analysis of Melamine in Milk Products on Agilent 789A/5975C GC/MSD Using a ew Agilent J&W DB-5ms Ultra Inert Column and SampliQ SCX Cartridges Application ote Gas Chromatography/Mass Spectrometry/Food

More information

EGASUS. 4D GCxGC TOFMS. Delivering the Right Results

EGASUS. 4D GCxGC TOFMS. Delivering the Right Results P EGAU 4D GCxGC TFM Delivering the Right Results LEC s P EGAU 4D GCxGC-TFM The Ultimate Analytical Instrument Pioneering GCxGC technology, combined with the Pegasus TFM and ChromaTF software provides today

More information

Determination of Volatile Aromatic Compounds in Soil by Manual SPME and Agilent 5975T LTM GC/MSD

Determination of Volatile Aromatic Compounds in Soil by Manual SPME and Agilent 5975T LTM GC/MSD Determination of Volatile Aromatic Compounds in Soil by Manual SPME and Agilent 5975T LTM GC/MSD Application Note Environmental Author Suli Zhao, Andy Zhai Agilent Technologies Co., Ltd. 412 Yinglun Road

More information

Applying the Agilent 5977A MSD to the Analysis of USP<467> Residual Solvents with the 7697A Headspace Sampler and 7890B GC

Applying the Agilent 5977A MSD to the Analysis of USP<467> Residual Solvents with the 7697A Headspace Sampler and 7890B GC Applying the Agilent 5977A MSD to the Analysis of USP Residual Solvents with the 7697A Headspace Sampler and 7890B GC Application Note Pharmaceuticals Authors Roger L. Firor and Mike Szelewski Agilent

More information

Column Dimensions. GC Columns and Consumables. Mark Sinnott Application Engineer. March 12, 2010

Column Dimensions. GC Columns and Consumables. Mark Sinnott Application Engineer. March 12, 2010 Secrets of GC Column Dimensions GC Columns and Consumables Mark Sinnott Application Engineer Folsom California March 12, 2010 Page 1 Secrets of GC Column Dimensions Do I have the right column phase? Resolution

More information

Analysis of Geosmin and 2-Methylisoborneol Utilizing the Stratum PTC and Aquatek 70

Analysis of Geosmin and 2-Methylisoborneol Utilizing the Stratum PTC and Aquatek 70 Analysis of Geosmin and 2-Methylisoborneol Utilizing the Stratum PTC and Aquatek 70 Application Note Abstract Geosmin and 2-Methylisoborneol are organic compounds that have a distinct scent. These compounds

More information

Analytical Instrumentation

Analytical Instrumentation Gas Chromatography and Mass Spectrophotometry Environmental, food safety, toxicology, and forensic gas chromatography applications are more demanding than ever. Our portfolio of GC, GC- MS, GC-MS/MS and

More information

Application Note. Author. Abstract. Introduction. Hydrocarbon Processing

Application Note. Author. Abstract. Introduction. Hydrocarbon Processing Automated Preparation of Simulated Distillation Standards and Samples for ASTM Methods D2887, D7213, D7398 and D6352 using the 7693A System with Easy SamplePrep Software Author Roger L. Firor Agilent Technologies,

More information

COOKBOOK FOR THE PERKINELMER SWAFER TM TECHNOLOGY FOR GC APPLICATIONS

COOKBOOK FOR THE PERKINELMER SWAFER TM TECHNOLOGY FOR GC APPLICATIONS COOKBOOK FOR THE PERKINELMER SWAFER TM TECHNOLOGY FOR GC APPLICATIONS INTRODUCTION The Swafer TM system uses small circular metal disks into which micro-channels have been laser fabricated to provide flow

More information

Improved Volatiles Analysis Using Static Headspace, the Agilent 5977B GC/MSD, and a High-efficiency Source

Improved Volatiles Analysis Using Static Headspace, the Agilent 5977B GC/MSD, and a High-efficiency Source Improved Volatiles Analysis Using Static Headspace, the Agilent 5977B GC/MSD, and a High-efficiency Source Application Note Environmental Authors Peter Gautschi and Harry Prest Senior Application Scientist

More information

Introduction to Capillary GC

Introduction to Capillary GC Introduction to Capillary GC LC Columns and Consumables Simon Jones Chromatography Applications Engineer February 20, 2008 Page 1 Introduction to Capillary GC t r K c?? Kβ k = - tr t m? t m R s Page 2

More information

Harris: Quantitative Chemical Analysis, Eight Edition CHAPTER 23: GAS CHROMATOGRAPHY

Harris: Quantitative Chemical Analysis, Eight Edition CHAPTER 23: GAS CHROMATOGRAPHY Harris: Quantitative Chemical Analysis, Eight Edition CHAPTER 23: GAS CHROMATOGRAPHY Chapter 23. Gas Chromatography What did they eat in the year 1,000? GC of Cholesterol and other lipids extracted from

More information

The determination of residual solvents in pharmaceuticals using the Agilent G1888 headspace/6890n GC/5975 inert MSD system Application Note

The determination of residual solvents in pharmaceuticals using the Agilent G1888 headspace/6890n GC/5975 inert MSD system Application Note The determination of residual solvents in pharmaceuticals using the Agilent G1888 headspace/6890n GC/5975 inert MSD system Application Note Roger L. Firor Albert E. Gudat Abstract The Agilent G1888 network

More information

MassHunter TOF/QTOF Users Meeting

MassHunter TOF/QTOF Users Meeting MassHunter TOF/QTOF Users Meeting 1 Qualitative Analysis Workflows Workflows in Qualitative Analysis allow the user to only see and work with the areas and dialog boxes they need for their specific tasks

More information

Simultaneous Compound Identification and Quantification with Parallel Polyarc /FID and MS

Simultaneous Compound Identification and Quantification with Parallel Polyarc /FID and MS Simultaneous Compound Identification and Quantification with Parallel Polyarc /FID and MS Application Note Multi-detector Splitter Authors Charlie Spanjers and Andrew Jones Activated Research Company 7561

More information

Introduction to Capillary GC. Page 1. Agilent Restricted February 2, 2011

Introduction to Capillary GC. Page 1. Agilent Restricted February 2, 2011 ?? Kβ? Page 1 Typical GC System Gas supply Injector Detector Data handling GAS Column Oven Page 2 CARRIER GAS Carries the solutes down the column Selection and velocity influences efficiency and retention

More information

Rapid, Robust, and Sensitive Detection of 11-nor-D 9 - Tetrahydrocannabinol-9-Carboxylic Acid in Hair

Rapid, Robust, and Sensitive Detection of 11-nor-D 9 - Tetrahydrocannabinol-9-Carboxylic Acid in Hair Rapid, Robust, and Sensitive Detection of -nor-d 9 - Tetrahydrocannabinol-9-Carboxylic Acid in Hair Application Note Forensic Toxicology/Doping Control Authors David Engelhart Omega Labs, Inc. Mogadore,

More information

A Comparative Analysis of Fuel Oxygenates in Soil by Dynamic and Static Headspace Utilizing the HT3 TM Automatic Headspace Analyzer

A Comparative Analysis of Fuel Oxygenates in Soil by Dynamic and Static Headspace Utilizing the HT3 TM Automatic Headspace Analyzer A Comparative Analysis of Fuel Oxygenates in Soil by Dynamic and Static Headspace Utilizing the HT3 TM Automatic Headspace Analyzer Application Note By: Anne Jurek Abstract This application note presents

More information

Fast Analysis of USP 467 Residual Solvents using the Agilent 7890A GC and Low Thermal Mass (LTM) System

Fast Analysis of USP 467 Residual Solvents using the Agilent 7890A GC and Low Thermal Mass (LTM) System Fast Analysis of USP 7 Residual Solvents using the Agilent 789A GC and Low Thermal Mass (LTM) System Application Note Pharmaceutical Author Roger L Firor Agilent Technologies, Inc. 8 Centerville Road Wilmington,

More information

Selection of a Capillary

Selection of a Capillary Selection of a Capillary GC Column - Series 3 Mark Sinnott Application Engineer March 19, 2009 Page 1 Typical Gas Chromatographic System Mol-Sieve Traps Fixed Restrictors Regulators Injection Port Detector

More information

GC Analysis of Polybrominated Flame Retardants Application

GC Analysis of Polybrominated Flame Retardants Application GC Analysis of Polybrominated Flame Retardants Application Environmental Authors Eberhardt Kuhn, Jason Ellis Agilent Technologies, Inc. 91 Blue Ravine Rd, Folsom, CA 9563 USA Steve Wilbur Agilent Technologies,

More information

The Analysis of Residual Solvents in Pharmaceutical Products Using GC-VUV and Static Headspace

The Analysis of Residual Solvents in Pharmaceutical Products Using GC-VUV and Static Headspace The Analysis of Residual Solvents in Pharmaceutical Products Using GC-VUV and Static Headspace The Analysis of Residual Solvents in Pharmaceutical Products Using GC-VUV and Static Headspace_Rev3 Introducing

More information

Agilent G3212 GC-APCI Source

Agilent G3212 GC-APCI Source Agilent G3212 GC-APCI Source Quick Start Guide Where to find information 2 Getting Started 3 Step 1. Start the Data Acquisition program for the GC and the Q-TOF 3 Step 2. Prepare the GC and Q-TOF for data

More information

Agilent MassHunter Quantitative Data Analysis

Agilent MassHunter Quantitative Data Analysis Agilent MassHunter Quantitative Data Analysis Presenters: Howard Sanford Stephen Harnos MassHunter Quantitation: Batch and Method Setup Outliers, Data Review, Reporting 1 MassHunter Quantitative Analysis

More information

Screening of Pesticide Residues in Water by Sequential Stir Bar Sorptive Extraction-Thermal Desorption with GC/MS

Screening of Pesticide Residues in Water by Sequential Stir Bar Sorptive Extraction-Thermal Desorption with GC/MS Screening of Pesticide Residues in Water by Sequential Stir Bar Sorptive Extraction-Thermal Desorption with GC/MS Application Note Food Authors Nobuo Ochiai and Kikuo Sasamoto GERSTEL K.K. 2-13-18 Nakane

More information

The 5975 inert MSD Benefits of Enhancements in Chemical Ionization Operation Technical Note

The 5975 inert MSD Benefits of Enhancements in Chemical Ionization Operation Technical Note The 5975 inert MSD Benefits of Enhancements in Chemical Ionization Operation Technical Note Authors Chris Sandy Agilent Technologies Wokingham, Berkshire, UK Jean-Francois Garnier Agilent Technologies

More information

Enhanced Simultaneous Total ion and Selective Multi-Ion GC/MS Using a Combination of New Software and Low-Bleed Columns

Enhanced Simultaneous Total ion and Selective Multi-Ion GC/MS Using a Combination of New Software and Low-Bleed Columns Enhanced Simultaneous Total ion and Selective Multi-Ion GC/MS Using a Combination of New Software and Low-Bleed Columns Martin Okiro and Robert Wohleb VICI Gig Harbor Group Inc, P.O. Box 2657, Gig Harbor,

More information

GC Resolution Do You See What I See?

GC Resolution Do You See What I See? GC Resolution Do You See What I See? Column Dimensions and Carrier Gas Optimization Deans Switch Page 1 Variables for Maximizing Resolution Optimized Stationary Phase Longer Column Length Decrease Internal

More information

Determination of Volatile Substances Proof of Food Adulteration

Determination of Volatile Substances Proof of Food Adulteration ANALYSIS OF FOOD AND NATURAL PRODUCTS LABORATORY EXERCISE Determination of Volatile Substances Proof of Food Adulteration (method: gas chromatography with mass spectrometric detection) Exercise guarantor:

More information

Gas Chromatography. Rosa Yu, David Reckhow CEE772 Instrumental Methods in Environmental Analysis CEE 772 #16 2

Gas Chromatography. Rosa Yu, David Reckhow CEE772 Instrumental Methods in Environmental Analysis CEE 772 #16 2 Print version Gas Chromatography Rosa Yu, David Reckhow CEE772 Instrumental Methods in Environmental Analysis CEE 772 #16 1 Contents The primary components to a GC system 1. Carrier Gas System (including

More information

Hans-Joachim Hubschmann. Handbook ofgc-ms. Fundamentals and Applications. Third Edition. Wl LEY-VCH. VerlagGmbH & Co. KG aa

Hans-Joachim Hubschmann. Handbook ofgc-ms. Fundamentals and Applications. Third Edition. Wl LEY-VCH. VerlagGmbH & Co. KG aa Hans-Joachim Hubschmann Handbook ofgc-ms Fundamentals and Applications Third Edition Wl LEY-VCH VerlagGmbH & Co. KG aa VII Foreword XIII Preface to the Third Edition XV 1 Introduction 1 1.1 The Historical

More information

Agilent 6400 Series Triple Quadrupole Users Workshop. MH QQQ Users workshop 2/21/2014 1

Agilent 6400 Series Triple Quadrupole Users Workshop. MH QQQ Users workshop 2/21/2014 1 Agilent 6400 Series Triple Quadrupole Users Workshop 1 Agilent 6400 Series Triple Quadrupole Users Workshop QQQ Method Development and Optimization MassHunter Quantitation: Batch and Method setup QC s,

More information

Analysis of Sulfur-Containing Flavor Compounds By GC/MS With A PFPD

Analysis of Sulfur-Containing Flavor Compounds By GC/MS With A PFPD Analysis of Sulfur-Containing Flavor Compounds By GC/MS With A Application Note 19060203 Keywords Coffee Essential Oil Flavor Fragrance Gas Chromatograph (GC) Sulfur Compounds Abstract Sulfur compounds

More information

Automated and accurate component detection using reference mass spectra

Automated and accurate component detection using reference mass spectra TECHNICAL NOTE 72703 Automated and accurate component detection using reference mass spectra Authors Barbara van Cann 1 and Amit Gujar 2 1 Thermo Fisher Scientific, Breda, NL 2 Thermo Fisher Scientific,

More information

Detection of Chemical Warfare Agents by Transportable GC/MS

Detection of Chemical Warfare Agents by Transportable GC/MS Detection of Chemical Warfare Agents by Transportable GC/MS Application Note Gas Chromatography/Mass Spectrometry Author Robert V. Mustacich Agilent Technologies, Inc. 5301 Stevens Creek Boulevard Santa

More information

Characterisation of allergens in cosmetics by GC GC TOF MS with Select-eV variable-energy electron ionisation

Characterisation of allergens in cosmetics by GC GC TOF MS with Select-eV variable-energy electron ionisation Application Released: January 214 Application Note 522 Characterisation of allergens in cosmetics by GC GC TF MS with Select-eV variable-energy electron ionisation Summary This Application Note shows that

More information

Innovative Thermal Desorption From Agilent Technologies. Vivek Dhyani Application Chemist

Innovative Thermal Desorption From Agilent Technologies. Vivek Dhyani Application Chemist Innovative Thermal Desorption From Agilent Technologies Vivek Dhyani Application Chemist What is thermal desorption (TD)? How does thermal desorption compare to Head Space? Thermal desorption (TD) is the

More information

Analysis of Biomarkers in Crude Oil Using the Agilent 7200 GC/Q-TOF

Analysis of Biomarkers in Crude Oil Using the Agilent 7200 GC/Q-TOF Analysis of Biomarkers in Crude Oil Using the Agilent 7 GC/Q-TOF Application Note Petrochemical and Environmental Authors Frank David Research Institute for Chromatography, Kennedypark 6, B-85 Kortrijk,

More information

Optimizing Conditions for Volatiles Analysis

Optimizing Conditions for Volatiles Analysis July 2016 SPEXCertiPrep.com/ECS Optimizing Conditions for Volatiles Analysis by Mark A. Ferry GC/MS Technical Consultant MFerry@SPEX.com A publication by Environmental Consulting & Supplies a Division

More information

STANDARD OPERATING PROCEDURES SOP: 1828 PAGE: 1 of 14 REV: 0.0 DATE: 05/12/95 ANALYSIS OF METHYL PARATHION IN CARPET SAMPLES BY GC/MS

STANDARD OPERATING PROCEDURES SOP: 1828 PAGE: 1 of 14 REV: 0.0 DATE: 05/12/95 ANALYSIS OF METHYL PARATHION IN CARPET SAMPLES BY GC/MS PAGE: 1 of 14 1.0 SCOPE AND APPLICATION 2.0 METHOD SUMMARY CONTENTS 3.0 SAMPLE PRESERVATION, CONTAINERS, HANDLING AND STORAGE 4.0 INTERFERENCES AND POTENTIAL PROBLEMS 5.0 EQUIPMENT/APPARATUS 6.0 REAGENTS

More information

THE NEW QUANTITATIVE ANALYTICAL METHOD FOR ULTRATRACE SULFUR COMPOUNDS IN NATURAL GAS

THE NEW QUANTITATIVE ANALYTICAL METHOD FOR ULTRATRACE SULFUR COMPOUNDS IN NATURAL GAS International Gas Union Research Conference 14 THE NEW QUANTITATIVE ANALYTICAL METHOD FOR ULTRATRACE SULFUR COMPOUNDS IN NATURAL GAS Main author Hironori IMANISHI Tokyo Gas Co., Ltd. JAPAN himanishi@tokyo-.co.jp

More information

Meeting Challenging Laboratory Requirements for USEPA Method 8270 Using a Highly Sensitive, Robust, and Easy-to-Use GC/MS

Meeting Challenging Laboratory Requirements for USEPA Method 8270 Using a Highly Sensitive, Robust, and Easy-to-Use GC/MS Application Note # CA 284780 Meeting Challenging Laboratory Requirements for USEPA Method 8270 Using a Highly Sensitive, Robust, and Easy-to-Use GC/MS Abstract The analysis of semi-volatile organic compounds

More information

Gas chromatography. Advantages of GC. Disadvantages of GC

Gas chromatography. Advantages of GC. Disadvantages of GC Advantages of GC Gas chromatography Fast analysis, typically minutes Effi cient, providing high resolution Sensitive, easily detecting ppm and often ppb Nondestructive, making possible on - line coupling;

More information

Analyzing Semi-Volatiles by GC-MS

Analyzing Semi-Volatiles by GC-MS Analyzing Semi-Volatiles by GC-MS Jonathan A. Karty July 31, 2008 Overview GC-MS Instrumentation Description GC-MS Method Sections In Detail Sequence Programming Data Analysis Tips and Tricks 1 Quick Description

More information

Analysis of Total PCBs and PCB Congeners and Trans-nonachlor in Fish by Gas Chromatography/ Negative Chemical Ionization Single Ion Mass Spectrometry

Analysis of Total PCBs and PCB Congeners and Trans-nonachlor in Fish by Gas Chromatography/ Negative Chemical Ionization Single Ion Mass Spectrometry Analysis of Total PCBs and PCB Congeners and Trans-nonachlor in Fish by Gas Chromatography/ Negative Chemical Ionization Single Ion Mass Spectrometry Standard Operating Procedure SOP No. HC 519.D (Replaces:

More information

ANNE JUREK. Abstract: soils and are found. in can also with GC/MS. poster. in series. option for. There are problems. analytes. in methanol.

ANNE JUREK. Abstract: soils and are found. in can also with GC/MS. poster. in series. option for. There are problems. analytes. in methanol. Determination of Volatile Petroleum Hydrocarbons ANNE JUREK Abstract: Due to current events, the importance of determining volatile petroleum hydrocarbons in both soils and waters has become an issue.

More information

Forensic Toxicology. Analysis of Ethanol in Blood using Master SHS Static Headspace Sampler and Master GC Gas Chromatograph APPLICATION NOTE

Forensic Toxicology. Analysis of Ethanol in Blood using Master SHS Static Headspace Sampler and Master GC Gas Chromatograph APPLICATION NOTE Analysis of Ethanol in Blood using Master SHS Static Headspace Sampler and Master GC Gas Chromatograph APPLICATION NOTE Authors: DANI Instruments SpA viale Brianza, 87 Cologno Monzese Milano Italy Key

More information

Get Selective. By Jaap de Zeeuw

Get Selective. By Jaap de Zeeuw 34 Get Selective Modern narrow bore columns have made chromatographers lazy when it comes to stationary phase selection. Here s how getting back to basics in gas chromatography by using selectivity can

More information

Gas Chromatography (GC)! Environmental Organic Chemistry CEE-PUBH Analysis Topic 5

Gas Chromatography (GC)! Environmental Organic Chemistry CEE-PUBH Analysis Topic 5 Gas Chromatography (GC)! Environmental Organic Chemistry CEE-PUBH 5730-6730 Analysis Topic 5 Chromatography! Group of separation techniques based on partitioning (mobile phase/stationary phase). Two immiscible

More information

Introduction to GC/MS

Introduction to GC/MS Why Mass Spectrometry? Introduction to GC/MS A powerful analytical technique used to: 1.Identify unknown compounds 2. Quantify known materials down to trace levels 3. Elucidate the structure of molecules

More information

GCXGC-qMS with Total Flow Modulation for Volatile secondary metabolites analysis from organically-grown apples by HS-SPME

GCXGC-qMS with Total Flow Modulation for Volatile secondary metabolites analysis from organically-grown apples by HS-SPME GCXGC-qMS with Total Flow Modulation for Volatile secondary metabolites analysis from organically-grown apples by HS-SPME Users Meeting RIVA DEL GARDA 20 May 2014 Eligio Sebastiani - SRA Instruments SpA

More information

Comprehensive Pesticide Screening by GC/MSD using Deconvolution Reporting Software Application

Comprehensive Pesticide Screening by GC/MSD using Deconvolution Reporting Software Application Comprehensive Pesticide Screening by GC/MSD using Deconvolution Reporting Software Application Food Safety Author Philip L. Wylie, Michael J. Szelewski, and Chin-Kai Meng Agilent Technologies, Inc. 2850

More information

The Third Dimension of Information Vol. IV Applications with the Agilent Technologies Atomic Emission Detector. O H Cl. Fe Se

The Third Dimension of Information Vol. IV Applications with the Agilent Technologies Atomic Emission Detector. O H Cl. Fe Se The Third Dimension of Information Vol. IV Applications with the Agilent Technologies Atomic Emission Detector O H Cl Sn Fe Se S Author: Bernhard Rothweiler, Agilent Technologies Deutschland GmbH Index:

More information

A New Web-Based Application for Modeling Gas Chromatographic Separations

A New Web-Based Application for Modeling Gas Chromatographic Separations A New Web-Based Application for Modeling Gas Chromatographic Separations Jaap de Zeeuw**, Rebecca Stevens*, Amanda Rigdon, Linx Waclaski*and Dan Li* *Restek Corporation, Bellefonte, PA, USA **Restek Corporation,

More information

Benefits of Equipping your Lab with a Time-of-Flight Mass Spectrometer

Benefits of Equipping your Lab with a Time-of-Flight Mass Spectrometer Benefits of Equipping your Lab with a Time-of-Flight Mass Spectrometer Purchasing a mass spectrometer (MS) is an important investment for a laboratory. When considering instrument platforms, selection

More information