YOUNG LIN ACME 9000 HPLC

Size: px
Start display at page:

Download "YOUNG LIN ACME 9000 HPLC"

Transcription

1

2 YOUNG LIN ACME 9000 HPLC Young Lin Acme 9000 HPLC provides accuracy and precision required LC technology with 17 years experience and dedication in developing chromatography systems. The Acme 9000 HPLC gives you the perfect solution for a wide range of applications-semi-prep and narrow bore applications as well as general analytical application. Young Lin softwares would be satisfied with user s demands by controlling the HPLC modules such as pumps, detectors, column oven and an autosampler. Also the sophisticated softwares ensure you data acquisition and management capabilities required to increase productivity. Vacuum Degasser & Mixer - Solvent mixer for low pressure gradient - Up to 4 solvents use available -Teflon AF degassing membrane -Effective vacuum degassing Gradient Pump -Excellent flow precision(< 0.1 %) -Wide range of flow rates( 49 ml/min) - Auto-flushing function - Built-in gradient controller UV/Vis Detector - Simultaneous dual wavelength detection - High speed wavelength scanning - Easy maintenance and use

3 Solutions for Liquid Chromatograph Young Lin supports the best analytical solution for a wide range of applications by delivering specific systems as your needs. Autochro Satisfied with 21 CFR - Control of multi-system at the same time - No risks of data loss Cost Effective Valuable Flexible HPLC SYSTEM Autochro Easy control of system at low cost - Compatible with MS-Windows XP - Data acquisition in real time Autochro-GPC - Special software for polymer analysis - Simple and intuitive control Column Oven - Reliable analysis results with stable temperature control and programming - Easy installation of up to 30 cm columns - Safety function

4 A cme 9000 HPLC Analytical HPLC Young Lin Analytical HPLC consists of Gradient Pump has superior flow precision, wide flow range and auto-flushing function, UV/Vis Detector performs simultaneous dual wavelength analysis, wavelength scanning and remote control function, Vacuum Degasser & Mixer is used to degas and mix with solvents for low pressure gradient, Column Oven ensures precise temperature control and complete safety function, Autochro series Data System provides full control of instruments, data acquisition and management. Young Lin Analytical HPLC provides optimized systems in low and high pressure gradient application as well as isocratic application for routine analysis. Stability Automatic compressibility compensation function of the Gradient Pump provides stable flow by minimizing pulse from interruption during piston moving or refilling cycle. Vacuum Degasser & Mixer ensures very accurate mixing and stable degassing rate. Also forced air heat exchange control of the column oven keeps column temperature stably during HPLC analysis, and RI effect compensation function of the Dual Wavelength Detector by minimizing noise and drift give you optimized analysis results as stable baseline. Sensitivity Young Lin Analytical HPLC system provides high detectable sensitivity through precise flow control, stable baseline and perfect excluding from outside environment Gradient Pump - Flow range : ml/min - Precision : 0.1 % at 1 ml/min - Accuracy : 1 % at 1 ml/min UV/Vis Detector - Wavelength range : nm - Spectral bandwidth : 5 nm - Dual Wavelength

5 4 5 Stability, Sensitivity, Selectivity Selectivity Young Lin Analytical HPLC can be configured by various type of detector for specific application as well as UV/VIS detector for routine analysis. We provide - RI Detector for sugar and polymer analysis - Fluorescence Detector for analysis of PAHS, cabamate pesticide, alfatoxin, etc - Conductivity Detector for ion analysis - Electro chemical Detector for biogenic amines(catecholamines), amino acid, vitamin, ions, etc. - Evaporative Light Scattering Detector Powerful Control Autochro softwares are 32-bit chromatograph data system which performs instrument control, data acquisition, data management and report generation on a PC. The software can perfectly control the system including autosampler, pump, column oven, etc. Autochro-3000 Autochro-3000 is the software that is 32 bit and fully compatible with fully compatible with MS Windows XP. It provides independent module to manage data (Analysis) and control instruments (System) for optimized analysis condition. Vacuum Degasser & Mixer - Max flow rate : 10 ml/min - Teflon AF degassing membrane - Vacuum degassing Column Oven - Forced air heat exchange control - Temp. range : ambient to 85 - Precision : Temperature ramping programming - Easy view of statistics and overlay - Satisfied with 21 CFR - Strengthened user authentication for data reliability - Control of multi-system at the same time - Various analysis method applications - No risks of data loss Autochro-2000 The Autochro-2000 consists of instrument controlling part, data acquisition part and Data handling part. - Sophisticated and intuitive user interface - Report generation by MS Excel and MS Word - Data acquisition from up to 4 channels - Connectivity of Young Lin HPLC, GC - Data acquisition for non-young Lin detectors with AD module

6 A cme 9000 HPLC Semi-prep HPLC Maximum flow rate : 49 ml/min, The best Choice for Preparation of samples Our Acme Semi-preparative HPLC, configured with Semi-prep Gradient Pump, Solvent Mixer, Semi-prep UV/Vis Detector or RI Semi-prep Detector and Fraction collector provide preparation, separation and purification of up to milligrams samples Semi-prep Gradient Pump - Flow range : ml/min - Operating Pressure : 3,500 psi Semi-prep UV/Vis Detector - Exterior valve control for sample Purify ug - 10 s mg ug - mg Column ID mm mm Fluid handling unit - Max. Flow rate Acme Semi-prep - 49 ml Acme Analytical - 16 ml preparation and solvent recovery - Wavelength range : nm Path length : 3 mm, Cell volume : 5.3 ul FC203B Fraction Collector The FC 203B is a perfect compact fraction collector, capable of handling a wide variety of collection vessels, including microplates, vials and tubes. The built-in keypad makes set up with simple operation [Specification] Collection Modes : Manual, Time, Peak and time, Peak and drop Programmable Time Units : min per tube Multi Cycle Operation : Max. 99 cycles Multiple Column Collection : Simultaneous collection from up to 8 columns with installation of optional multiple column adaptor

7 6 7 Microbore HPLC Very convenient tool for the separation of Small Molecules in the Presence of Large Biomolecule HPLC analysis of small molecules contained with a protein matrix can be a difficult and time consuming task. The analysis often involves multi-step pretreatment procedures including centrifugation, extraction and filtration. Regis s RAM(Random Access Media) HPLC allows for the HPLC resolution of small molecules in the presence of much larger analytes without extensive sample pretreatment. With RAM direct injection HPLC columns, a variety of complex sample matrices can be injected directly, without sample clean-up, and drugs, drug metabolites, and other analytes can be separated and detected in minutes. RAM Direct Injection Advantages - Elimination of multiple sample pretreatment steps : Such as precipitation, centrifugation, solvent evaporation and residue dissolution steps. Simply filter samples and inject directly on to the column - Useful with a variety of sample matrices : Such as plasma, serum, whole blood, urine, plant and tissue extract - Compatibility with automated sample processing : Allows the use of automated HPLC system - Reduction of potentially dangerous sample handling : By elimination of multiple sample treatment steps - Reduction of bioharzardous waste : Compared with SPE sample preparation - The low cost solution : By simple sample preparation, just requires filtering Analysis Automation Our narrow bore HPLC with the RAM technology provides you with the best solution for automated separation of small molecules contained in the protein matrices. In the RAM column the smaller molecules are retained and concentrated, while most of the larger molecules are passed to waste. A stronger mobile phase is then used to elute the analytes onto a second column-often octadecylsilyl(ods)-where they are separated and analyzed. Recent column switching work involves the use of short RAM guard columns. The guard column is used to separate the analytes from the matrix before switching to an analytical column is an inexpensive and simpler alternative to Solid Phase Extraction(SPE). There are two RAM Direct Injection Technologies; - ISRP(Internal Surface Reverse Phase) such as GFF and GFF II for drugs, their metabolites and the resolution of peptides - SPS(Semi-Permeable Surface) such as Nitrile, Octyl C8, ODS C18 and Phenyl for analytical separation

8 A cme 9000 HPLC GPC system Acme GPC system can be used to determine average molecular weight and molecular weight distribution for polymers, rubbers, plastics and synthetic fibers. It provides all the information necessary to identify physical properties of polymers. As even a little error in measuring average molecular weight or molecular weight can impact the physical properties of final polymer products considerably, flow accuracy of pump and stability of RI Detector are critical factors for reliable GPC analysis. Autochro-GPC work station adds simple and convenient control for Acme GPC system The RI Detector as the detector for Acme GPC system provides high sensitivity, stability and reproducibility of the analysis result. with sensing difference of physical properties between polymers in detail RI Detector - Optical system of RI Detector - - Detection method : Deflection - RI Range : 1.00 to 1.75 RIU - Typical flow rate : 0.2 ~ 3.0 ml/min - Noise : 1.3 x 10-8 RIU - Auto zero range : 40 x 10-5 RIU - Auto zero resolution : ~ 5 x RIU - Recorder output : 1 V - Linear dynamic range : 80 x 10-5 RIU - Drift rate : 8 x 10-8 RIU - Cell volume : 9 ul - Cell pressure : 6 kg/cm 2 (84 psi) - Volume into cell : 24 ul - Temperature control : 35 ~ 55 - Digital interface : RS-232C - Digital input : Purge, Auto Zero - Dimension : 297 x 198 x 495 mm(w x H x D) - Power Requirements : 110/ % V, 50/60 Hz

9 8 9 IC system Cation analysis by Acme IC system Acme IC system performs ion analysis quickly and accurately. The system also ensures sensitivity and reproducible ion analysis at up to ppb concentration level for ion analysis - Modular design for the flexibility as your needs - Precise flow control by high performance pump - Very stable base line by suppressor during anion analysis - High sensitive detectors (conductivity Detector, Electrochemical Detector) Isocratic HPLC Isocratic HPLC is for simple analysis that needs no change in solvent composition with economic price. Young Lin Isocratic system is the best solution for customers who operate analysis with single solvent in single wavelength detection from 190 to 600 nm. Isocratic Pump - Stable flow rate and pressure - Head volume : 64 ul - Available flow rate range : ~ 1 0 ml/min - Flow rate Accuracy : 2 %(at 1.0 ml/min) - Flow rate Precision : 0.2 %(RSD) UV Detector - Wavelength Range : 190~600 nm - Spectral Bandwidth : < 8 nm - Wavelength Accuracy : 1.0 nm - Wavelength Reproducibility : 0.1 nm - Monochromator Type : Czerny-Turner Mount

10 A cme 9000 HPLC System Automation Young Lin offers autosamplers from Spark Holland, our Autosampler OEM manufacturer, for a variety of tasks, ranging from general HPLC needs up to dedicated solutions for high sample throughput. - Basic Marathon Autosampler : designed specially for Quality Control HPLC - Midas Autosampler : with column oven, programmable injection volumes, reagent addition capability and sample tray cooling, Midas is an ideal autosampler for demanding routine analysis. - Triathlon Autosampler : with micro-sample handling, reagent addition and inert sampling with PEEK or fused silica needles. A wide range of sample vials can be used and peltier cooling is available for sample tray. Select one as variable functions, models, specifications Basic Marathon MIDAS Triathlon Sample capacity 96 vials 84 vials 96 vials(std) Methods Injection method Full loop Full / partial loop Full / partial loop Partial(optional) ul pick up ul pick up Injection volume ul ul ul Replicate injection Up to 9 Up to 9 Up to 9 Reproducibility RSD 0.5 % RSD 0.3 % RSD 0.3 % Memory effect < 0.2 % < 0.05 % < 0.01 % MIDAS Autosampler Manual Sample Injector The 316 stainless steel model 7725i and PEEK model 9725i are Rheodyne s most advanced manual sample injectors for analytical HPLC. Rheodyne manual sample injectors are also available for narrow bore, analytical and preparative scale analyses. Analytical Semi-prep Model 7725i 9725i 3725i i Materials 316SS PEEK 316SS PEEK Max. Pressure 7000 psi 5000 psi 5000 psi 4000 psi Max. Temperature Range of Loop Vol 80 2 ul - 5 ml 50 2 ul - 10 ml 50 2 ml - 20 ml 7725i Injector MX Semi-Automatic Switching Valve MX modules can be operated by push button, allowing them to function as a manual valves, or by contract closure for automated remote control. MX modules are also available in Analytical-Scale six-port and Ten-port switching valves with low dispersion. The MX modules are designed to increase productivity, expand laboratory capabilities, save time, and make life easier. MX series

11 Optimized HPLC Post-Column Derivatization system Pickering Laboratories, Inc., California, USA, a leading company of post-column derivatization chemistries and technology, has made a contract to supply the post-column derivatization system based on our Acme 9000 HPLC system. The PINNACLE PCX combined with Young Lin HPLC system offers the complete package of chemicals, columns, methods and post-column systems and reflects the ease of use, reliability and ruggedness you have come to expect. Applications - Powerful Software Control - Electronic Syringe Pump & Valve - Flexible Reactor - Column Heater Fast & Stable - Usability Design - Special Columns & Chemistries Aminoglycoside Antibiotics, Amino Acids, Biogenic Amines, Bromate, Carbamate Pesticides, Chromium VI, Formaldehyde, Glyphosate Herbicide, Guanidinos, Hexosamines, Mycotoxins, Paralytic Shellfish Toxins, Paraquat & Diquat, Polyphospates/Phosphonates, Polyether Antibiotics, Sulfa Drugs, Transition/Rare, Earth Metals, Vitamins B1, B6, and more Specifications of Pinnacle PCX series Reagent Pump - Pulse free syringe pump - Single piece ceramic barrel - Programmable flow rate - Flow range : ul/min - Automatic piston wash - Automatic reagent flush Reactor - Heated reactor : Easy replacement coil Thermal safety switch Column Heater - Temperature Programmable - Easy Column access Safeguards - In line check valve : prevent reagent back flow - Replaceable column & reagent filters - Post column system over pressure - Back pressure regulator : prevent detector noise Access to all components of the PINNACLE PCX is from the front of the instrument. All substitutions and installations can be performed by the user.

12 A cme 9000 HPLC Others Evaporative Light Scattering Detector(ELSD) The ZAM 3000 ELSD can detect any compound less volatile than the mobile phase to low nanogram levels as universal detector at an affordable price. It is used to analyze components which do not have UV absorption, cannot be separated with an isocratic solvent and must use a gradient elution, which can t be used with a Refractive Index Detector. Light Source : LED Detector : Photomultiplier Temperature Range : Ambient to 70 Gas Flow for Nebulizer : 1 L/min Gas Flow for additional rotatory Drying Gas : 2 L/min Gas Flow controlls : - Built-in flow controller for the additional drying gas. - EPC (Electronic Pressure Control) for the Nebulizationgas - Instrument Control : Keyboard and RS232 Nitrogen Generator for LC-MS The nitrogen generator produces high purity nitrogen gas from compressed air. The nitrogen gas is essential product to operate LC/MS or LC/MS/MS for saving cost and improving safety. [AT Series Nitrogen Generator] -Oil free compressor built-in - Drain processing needlessness - Maintenance Free - Five-kind filter built-in -N2 gas mass flow : 16 L/min -N2 gas concentration : 99 % -Noise value : 46 db -N2 gas pressure : 0.69 MPa In line Degasser - High Efficiency Degassing - Continuous Monitoring for Leaks and Errors - Smallest Foot Print Available - Quiet, Long-Life Operation - Two and Four Channel Models Electrochemical Detector DECADE II ECD is a detector for HPLC applied to variable analyses biogenicamines, phenols, vitamins, DNA adducts, inorganic ions and amino acids. Sensitive : strongly improved noise suppression by ADF Accurate : integrated, shielded column/flow cell oven Flexible : time-based, full parametric control Versatile : dual flow cell control [Application] -Toxicology : Overdose monitoring -Diagnostics : Catecholamine / Homocysteine -Pharmaceutical : Drug Discovery / Micro Dialysis - Environmental : Phenols / Pesticides -Food : Carbohydrates Radio-HPLC Detector [Special Detector for Radioisotope Analysis] The most important use of radioisotopes in bio-medical research is to label compounds so that quantities too small for chemical analysis can be traced through biological processes. The B Ram and r Ram Detectorcan use to detect very small quantities by labeling compounds. - RAM detector - RAM detector

13 Fluorescence Detector The detector is a highly sensitive,scanning fluorescence detector forliquid chromatography. It providesexceptional optical performance and operational flexibility for routine and trace analyses. - Optical design Dual monochromators using concave holographic diffraction gratings; stepper-motor driven - Wavelength range 200 to 650 nm excitation and emission; 200 to 800 nm emission with optional extendedrange(red-sensitive) PMT - 4 user files protected in nonvolatile memory, Spectral scanning(automatic or manual; 100 steps per second) Smartline UV Detector 2600 [ Multi-wavelength spectro-photometer based on diode array technology] The Smartline UV Detector 2600 can simultaneously measure at up to four freely programmable detection channels with high sensitivity and continuously record spectra in a selectable scan-range. With the level and event outputs, it is even possible to set up software-independent solvent recycling by just adding a 3-port solenoid valve. Diode Array : 256 diodes (1.25 nm /diode) Wavelength Range / Channels : nm / 4 (data recording) Light Source : deuterium Wavelength Accuracy / Bandwidth : 1 nm (254 nm) / 4-25 nm (selectable) Spectra Scan : max. 10 scans per second Noise / Drift (ASTM E ) : 1x10-5 AU /h 5x10-4 AU/h Programming : max. 20 programs Vector PCX Post-Column Derivatization Instrument [ SIGNIFICANT SAVINGS AND DEPENDABLE, UNPARALLELED ACCURACY] Low-pulsation metering pumps and state of the art flow conditioners provide cleaner readings than other post-column systems, allowing the consistent detection of low concentrations of analytes with extreme specificity and the highest degree of sensitivity, stability and reproducibility. No computer required for operation Positive displacement reciprocating pumps State of the art pulse dampening system Precision heated reactor Software-controlled pump flow rates Low pulsation precision metering pumps Basic Marathon [ Cost effective autosampler with great performance] Many samples require refrigeration to keep them stable and many lab's require instruments with a small footprint because bench space is expensive. The BasicMarathon offers both. The compact size of the standard unit remains unchanged when the thermo-electric (Peltier) cooling device is installed inside its cabinet. With 96 vial capacity and vial volume up to 5 ul this autosampler is really a small giant. Precision : flushed loop injections: RSD < 0.5 %, partial loop-filling : RSD < 1 % Carry over : < 0.2 %, using wash between injections. Replicate injections : Up to 9 Tray capacity : Standard : 96 vials of 1.8 ml, in 4 removable segments

14 A cme 9000 HPLC Specifications Gradient Pump - Selectable - Model Pump Head Volume Flow Range(ml/min) Operation Pressure (psi) In-line Filter(micron) Flow Path material Narrow Bore 25 ul x ~ ,000 2 PEEK Sapphire Zirconium Analytical Semi-prep 64 ul x ul x ~ ~ 49 6,000 3, SUS316, Sapphire Zirconium [Specification] - Solvent delivery mode : Ultra-stable dual reciprocating parallel pistons - Flow precision : 0.1% RSD - Flow accuracy : 1% - Pressure pulsation : 1% Amplitude at 1 ml/min - Constant Pressure Mode - Compressibility compensation : Automatic - Master & slave function for High pressure gradient - GLP Feature : Elapsed Time, Delivery Volume, Viscosity, Ratio, Pressure, Flow Rate, Composition - Control Mode : Isocratic, Constant Pressure, Gradient, Slave - Control and Communication : RS - 232C - Low Pressure Gradient : up to 4 Solvents - High Pressure Gradient : up to 3 Solvents - Composition Precision : < 0.1 % - Composition Accuracy : < 0.5 % - System Volume for High Pressure : 0.8 ~ 1.1 ml - System Volume for Low Pressure : 0.5 ~ 1.0 ml - 40 Gradient and Event Programs Store - Event Control : Gradient Table, Event Table, TTL and Solenoid Switch 1 ~ 3, Pressure Out,Composition Out, Alarm, Gradient Table Chain - Gradient Profiles with Linear, Step and Exponential - Automatic plunger wash and flushing - Prime/purge - Display : 2 lines, 20 characters LCD - Dimensions : 297(W) x 198(H) x 495(D) mm - Power Requirements : 110/220 V, 50/60 Hz Vacuum Degasser & Mixer - Max. Flow Rate : 10 ml/min per channel - Degassing Channel Tubing : Teflon AF degassing membrane - Degassing Channel Pressure Rate : 70 PSIG(testing pressure) - Vacuum Wetted Materials : Teflon AF, Peek, Class-filled PTFE - Valve electrical specification : DC 12 V, 2.5 W, 211 ma, F - Valve module leak rate : < 1 x 10-6 cc/sec Helium ATM - Power requirements : AC 220 V, 50/60 Hz, 25 W - Dimensions : 297 x 135 x 495 mm (W x H x D)

15 UV/ Vis Detector - Selectable - Model Path Length(mm) Cell Volume (ul) Tubing (ID) Cell Pressure(psi) Flow Path Material Narrow Bore > 1,500 PEEK Teflon Sapphire Analytical Semi-prep > 1,500 > 1,000 SUS316 Teflon Zirconium [Specification] - Wavelength range : nm - Spectral bandwidth : 5 nm - Wavelength Accuracy : 1 nm - Wavelength Precision : 0.1 nm - Monochromator type : Czerny-Tuner Mount (Blazed Holographic Grating) - Baseline noise : < 2 x 10-5 AU at 254 nm - Baseline drift : < 2 x 10-4 AU at 254 nm - Linearity : > 99.5 % at 1.0 AU (acetone, 254 nm) - Simultaneous dual wavelength detection with two lamps (Deuterium lamp, 2,000 hrs life, 0.5 mm Arc and tungsten lamp used) - Attenuation : 0.5 x Time Constant : 0.1 to 9.9 sec - Flow cell type : Cone type, 10 ul cell volume - Display : 2 Lines x 20 Characters - Dimension : 297(W) x 198(H) x 495(D) mm - Power Requirements : 110/220 V, 50/60 Hz Column Oven - Wide Temperature Range : Ambient to 85 - Accuracy : Temperature Heating Rate : 7 /min - Stability : Temperature Programs : 20 files / 40 steps - LCD display : current and setup temperature, error, elapsed time, 16 characters x 2 lines - Safety function : Upper temperature limit, leak sensor, flammable gas sensor, Over-heat protection, Lower temperature limit, Alarm for oven door opening. - Total installable column : up to 30 cm and 4 columns - Dimension : 210 x 550 x 415 mm (W x H x D) - Power Requirements : AC 110/220 V, 50/60 Hz, 3A

16 These products are manufactured by Young Lin ISO 9001-certified facility that is periodically audited by the registering body to ensure compliance Publication No.: YL-MKT-040 Date: November Hogye-dong, dongan-gu, Anyang, Kyounggi, , Korea TEL: FAX : younglin@younglin.com Homepage :

ION CHROMATOGRAPHY SYSTEM S 150

ION CHROMATOGRAPHY SYSTEM S 150 ION CHROMATOGRAPHY SYSTEM S 150 WATER ANALYSIS ENVIRONMENTAL ANALYSIS ANION & CATION ANALYSIS ION CHROMATOGRAPHY IIon Chromatography is an analytical separation technique based on ionic interactions. Dissolved

More information

ChromTech HPLC System

ChromTech HPLC System ChromTech HPLC System High-prssure Gradient System (A) High-pressure pump: 2 pcs UV/VIS detector: 1 piece Gradient control module: 1 unit High-pressure gradient mixer: 1 piece Single channel chromatography

More information

YL9100 HPLC. Think Smart Work Better

YL9100 HPLC. Think Smart Work Better YL9100 HPLC Think Smart Work Better 2 YL9100 HPLC Young Lin's HPLC is built to provide an exceptional cost/performance ratio. Continued research and development provide high-end performance and features,

More information

YL9100 HPLC. Think Smart Work Better

YL9100 HPLC. Think Smart Work Better YL9100 HPLC Think Smart Work Better 2 YL9100 HPLC Young Lin's HPLC is built to provide an exceptional cost/performance ratio. Continued research and development provide high-end performance and features,

More information

Transferring HPLC methods from the HP 1090 Series to the Agilent 1100 Series HPLC system

Transferring HPLC methods from the HP 1090 Series to the Agilent 1100 Series HPLC system Transferring HPLC methods from the HP 1090 Series to the Agilent 1100 Series HPLC system Technical Note Introduction The HP 1090 Series HPLC system, introduced in 1983, is regarded to be an outstanding

More information

Varian Galaxie Chromatography Data System for Preparative HPLC

Varian Galaxie Chromatography Data System for Preparative HPLC Varian Galaxie Chromatography Data System for Preparative HPLC By Gary Burce Varian, Inc. 2700 Mitchell Drive, Walnut Creek, CA 95498 USA Abstract Galaxie is an ideal chromatography data system for the

More information

Chemistry Instrumental Analysis Lecture 31. Chem 4631

Chemistry Instrumental Analysis Lecture 31. Chem 4631 Chemistry 4631 Instrumental Analysis Lecture 31 High Performance Liquid Chromatography (HPLC) High Performance Liquid Chromatography (HPLC) High Performance Liquid Chromatography (HPLC) Solvent Delivery

More information

MODERN HPLC FOR PRACTICING SCIENTISTS

MODERN HPLC FOR PRACTICING SCIENTISTS MODERN HPLC FOR PRACTICING SCIENTISTS Michael W. Dong Synomics Pharmaceutical Services, LLC Wareham, Massachusetts WILEY- INTERSCIENCE A JOHN WILEY & SONS, INC., PUBLICATION Preface xv 1 Introduction 1

More information

ION CHROMATOGRAPHY IC-3000 SERIES EPC / PRODUCTS / APPLICATION / SOFTWARE / ACCESSORIES / CONSUMABLES / SERVICES. Analytical Technologies Limited

ION CHROMATOGRAPHY IC-3000 SERIES EPC / PRODUCTS / APPLICATION / SOFTWARE / ACCESSORIES / CONSUMABLES / SERVICES. Analytical Technologies Limited Turnkey Laboratories Solutions ION CHROMATOGRAPHY IC-3000 SERIES EPC / PRODUCTS / APPLICATION / SOFTWARE / ACCESSORIES / CONSUMABLES / SERVICES Analytical Technologies Limited An ISO 9001 Certified Company

More information

Agilent 385-ELSD Evaporative Light Scattering Detector

Agilent 385-ELSD Evaporative Light Scattering Detector Agilent 8-ELSD Evaporative Light Scattering Detector For Low Molecular Weight Compounds Data Sheet Introduction Evaporative light scattering detectors are ideal for detecting analytes with no UV chromophore

More information

The Low-Temperature Evaporative Light-Scattering Detector (LT-ELSD)

The Low-Temperature Evaporative Light-Scattering Detector (LT-ELSD) The Low-Temperature Evaporative Light-Scattering Detector (LT-ELSD) Basically all compounds which are less volatile than the mobile phase can be detected. Detection is based on a Universal property of

More information

881 Compact IC pro 882 Compact IC plus. Compact ion chromatography for intelligent, reliable and precise analysis

881 Compact IC pro 882 Compact IC plus. Compact ion chromatography for intelligent, reliable and precise analysis 881 Compact IC pro 882 Compact IC plus Compact ion chromatography for intelligent, reliable and precise analysis 881 Compact IC pro and 882 Compact IC plus the compact solution for routine analysis 02

More information

Agilent 385-ELSD Evaporative Light Scattering Detector

Agilent 385-ELSD Evaporative Light Scattering Detector Agilent 8-ELSD Evaporative Light Scattering Detector For Low Molecular Weight Compounds Data Sheet Introduction Evaporative light scattering detectors are ideal for detecting analytes with no UV chromophore

More information

2501 High Performance Liquid Chromatography

2501 High Performance Liquid Chromatography 2501 High Performance Liquid Chromatography High Performance Liquid Chromatography Scheme Chp25:: 1 High Performance Liquid Chromatography Components of HPLC High Performance Liquid Chromatography Scheme

More information

FLASH CHROMATOGRAPHY

FLASH CHROMATOGRAPHY Turnkey Laboratories Solutions FLASH CHROMATOGRAPHY FC 3065 EPC / PRODUCTS / APPLICATION / SOFTWARE / ACCESSORIES / CONSUMABLES / SERVICES Analytical Technologies Limited An ISO 9001 Certified Company

More information

Biochemistry. Biochemical Techniques HPLC

Biochemistry. Biochemical Techniques HPLC Description of Module Subject Name Paper Name 12 Module Name/Title 13 1. Objectives 1.1. To understand the basic concept and principle of 1.2. To understand the components and techniques of 1.3. To know

More information

LC III: HPLC. Originally referred to as High-Pressure Liquid Chromatography. Now more commonly called High Performance Liquid Chromatography

LC III: HPLC. Originally referred to as High-Pressure Liquid Chromatography. Now more commonly called High Performance Liquid Chromatography LC III: HPLC What is HPLC? Originally referred to as High-Pressure Liquid Chromatography Now more commonly called High Performance Liquid Chromatography In general: The instrument controlled version of

More information

High Performance Liquid Chromatography

High Performance Liquid Chromatography Updated: 3 November 2014 Print version High Performance Liquid Chromatography David Reckhow CEE 772 #18 1 HPLC System David Reckhow CEE 772 #18 2 Instrument Basics PUMP INJECTION POINT DETECTOR COLUMN

More information

High Performance Liquid Chromatography

High Performance Liquid Chromatography Updated: 3 November 2014 Print version High Performance Liquid Chromatography David Reckhow CEE 772 #18 1 HPLC System David Reckhow CEE 772 #18 2 1 Instrument Basics PUMP INJECTION POINT DETECTOR COLUMN

More information

Analytical Instrumentation

Analytical Instrumentation Gas Chromatography and Mass Spectrophotometry Environmental, food safety, toxicology, and forensic gas chromatography applications are more demanding than ever. Our portfolio of GC, GC- MS, GC-MS/MS and

More information

novaa 800 D Atomic Absorption Spectrometer

novaa 800 D Atomic Absorption Spectrometer Technical Data Atomic Absorption Spectrometer Cpt : +27 (0) 21 905 0476 Jhb : +27 (0) 11 794 Dbn : +27 (0) 31 266 2454 1/7 General The is a compact atomic absorption spectrometer with deuterium background

More information

DI 3500 Discrete Aoalvzer

DI 3500 Discrete Aoalvzer DI 3500 Discrete Aoalvzer Automated Chemistry and Ion Analysis ':t O+Analytical:!, A World ofsolutions. - Discrete Analysis Efficient Microscale Chemistry Increasingly laboratories are being challenged

More information

Agilent 1260 Infinity Evaporative Light Scattering Detector (ELSD)

Agilent 1260 Infinity Evaporative Light Scattering Detector (ELSD) Agilent 16 Infinity Evaporative Light Scattering Detector (ELSD) Data Sheet Introduction Evaporative light scattering detectors (ELSDs) are ideal for detecting analytes with no UV chromophore as they do

More information

GUIDELINES FOR THE DESIGN OF CHROMATOGRAPHIC ANALYTICAL METHODS INTENDED FOR CIPAC COLLABORATIVE STUDY

GUIDELINES FOR THE DESIGN OF CHROMATOGRAPHIC ANALYTICAL METHODS INTENDED FOR CIPAC COLLABORATIVE STUDY Page 1 of 13 CIPAC/4105/R GUIDELINES FOR THE DESIGN OF CHROMATOGRAPHIC ANALYTICAL METHODS INTENDED FOR CIPAC COLLABORATIVE STUDY Prepared for CIPAC by Dr M J Tandy*, P M Clarke and B White (UK) The rapid

More information

HPLC Workshop 16 June 2009 What does this do? Chromatography Theory Review Several chromatographic techniques Even though each method utilizes different techniques to separate compounds, the principles

More information

High Performance Liquid Chromatography

High Performance Liquid Chromatography High Performance Liquid Chromatography What is HPLC? It is a separation technique that involves: Injection of small volume of liquid sample Into a tube packed with a tiny particles (stationary phase).

More information

Setting the Standard for Advanced GPC/SEC Systems

Setting the Standard for Advanced GPC/SEC Systems Absolute molecular weight Molecular conformation Molecular size Solution viscosity Viscotek Setting the Standard for s ṙ ṙ Detailed specification sheets from Introducing the system - the leading solution

More information

Determination of Polymer Modifier in Asphalt

Determination of Polymer Modifier in Asphalt Standard Method of Test for Determination of Polymer Modifier in Asphalt AASHTO Designation: T xxx-xx (2005) 1. SCOPE 1.1. This method of test is used to determine the polymer content of an asphalt sample.

More information

881 Compact IC pro / 882 Compact IC plus for ion chromatography. Intelligent. Reliable. Precise.

881 Compact IC pro / 882 Compact IC plus for ion chromatography. Intelligent. Reliable. Precise. Ion analysis 881 Compact IC pro / 882 Compact IC plus for ion chromatography. Intelligent. Reliable. Precise. 881 Compact IC pro and 882 Compact IC plus. Intelligent. Reliable. Precise. Metrohm s top ion

More information

HPLC. High Performance Liquid Chromatography (HPLC) Harris Chapter 25

HPLC. High Performance Liquid Chromatography (HPLC) Harris Chapter 25 High Performance Liquid Chromatography (HPLC) Harris Chapter 25 12/1/2005 Chem 253 - Chapter 25 1 HPLC Separation of nonvolatile or thermally unstable compounds. If the analyte/sample can be found to be

More information

Bruker Daltonics. EASY-nLC. Tailored HPLC for nano-lc-ms Proteomics. Nano-HPLC. think forward

Bruker Daltonics. EASY-nLC. Tailored HPLC for nano-lc-ms Proteomics. Nano-HPLC. think forward Bruker Daltonics EASY-nLC Tailored HPLC for nano-lc-ms Proteomics think forward Nano-HPLC World-Class Performance with a Small Footprint Bruker Daltonics presents a nano-lc system, perfectly integrated

More information

Maximizing Triple Quadrupole Mass Spectrometry Productivity with the Agilent StreamSelect LC/MS System

Maximizing Triple Quadrupole Mass Spectrometry Productivity with the Agilent StreamSelect LC/MS System Maximizing Triple Quadrupole Mass Spectrometry Productivity with the Agilent StreamSelect LC/MS System Application Note Authors Kevin McCann, Sameer Nene, Doug McIntyre, Edmond Neo, Dennis Nagtalon, and

More information

costech instruments ECS 4010 Elemental Combustion System CHNS-O

costech instruments ECS 4010 Elemental Combustion System CHNS-O instruments ECS 4010 Elemental Combustion System CHNS-O costech Costech Analytical Tecnologies Inc. 26074 Avenue Hall, Suite 14 Valencia, CA 91355 - USA Phone: (661) 297-2395 Fax: (661) 297-5492 e-mail:

More information

Varian 385-LC. ELSD for Low Molecular Weight Compounds

Varian 385-LC. ELSD for Low Molecular Weight Compounds D ATA S H E E T Varian 8-LC EVAPORATIVE LIGHT SCATTERING DETECTOR ELSD for Low Molecular Weight Compounds Evaporative light scattering detectors are ideal for detecting analytes with no UV chromophore

More information

Sample Preparation. Approaches to Automation for SPE

Sample Preparation. Approaches to Automation for SPE Sample Preparation Approaches to Automation for SPE i Wherever you see this symbol, it is important to access the on-line course as there is interactive material that cannot be fully shown in this reference

More information

Varian 380-LC. ELSD for Routine HPLC and GPC Analysis. Key Benefits

Varian 380-LC. ELSD for Routine HPLC and GPC Analysis. Key Benefits D ATA S H E E T EVAPORATIVE LIGHT SCATTERING DETECTOR ELSD for Routine HPLC and GPC Analysis Evaporative light scattering detectors are ideal for detecting analytes with no UV chromophore as they do not

More information

NOTE: The color of the actual product may differ from the color pictured in this catalog due to printing limitation.

NOTE: The color of the actual product may differ from the color pictured in this catalog due to printing limitation. NOTE: The color of the actual product may differ from the color pictured in this catalog due to printing limitation. SCANNING UV VISIBLE SPECTROPHOTOMETER Features SCANNING UV VISIBLE SPECTROPHOTOMETER

More information

IRMS. perspective. Isotope Ratio Mass Spectrometry.

IRMS. perspective. Isotope Ratio Mass Spectrometry. IRMS perspective Isotope Ratio Mass Spectrometry www.nu-ins.com Perspective The Nu Instruments Perspective geometry forms the basis for two state of the art IRMS instruments. Designed for flexibility,

More information

Prep 150 LC System: Considerations for Analytical to Preparative Scaling

Prep 150 LC System: Considerations for Analytical to Preparative Scaling Andrew Aubin and Jo-Ann Jablonski Waters Corporation, Milford, MA, USA APPLICATION BENEFITS The Prep 150 LC System is an affordable, highly reliable system for preparative chromatography and is suitable

More information

LABOTRON EXTRACTION & SYNTHESIS 2450 MHz

LABOTRON EXTRACTION & SYNTHESIS 2450 MHz LABOTRON EXTRACTION & SYNTHESIS 2450 MHz The LABOTRON TM series is the generic name for a ground breaking range of integrated reactor and microwave transmission systems especially designed to carry out

More information

High Performance Liquid Chromatography

High Performance Liquid Chromatography STANDARDBASE techniques: High Performance Liquid Chromatography Drenthe College, The Netherlands 1. Introduction HPLC. High Performance Liquid Chromatography High Performance Liquid Chromatography (HPLC)

More information

High Pressure/Performance Liquid Chromatography (HPLC)

High Pressure/Performance Liquid Chromatography (HPLC) High Pressure/Performance Liquid Chromatography (HPLC) High Performance Liquid Chromatography (HPLC) is a form of column chromatography that pumps a sample mixture or analyte in a solvent (known as the

More information

HPLC Praktikum Skript

HPLC Praktikum Skript HPLC Praktikum Skript Assistants: Gianluca Bartolomeo HCI D330, 3 46 68, bartolomeo@org.chem.ethz.ch Sahar Ghiasikhou HCI E330, 2 29 29, ghiasikhou@org.chem.ethz.ch 1. Introduction In chromatographic techniques,

More information

PERSPECTIVE STABLE ISOTOPE RATIO MS

PERSPECTIVE STABLE ISOTOPE RATIO MS Nu Plasma II Multi-Collector ICP-MS Aspect HR Stable Isotope Ratio MS PERSPECTIVE STABLE ISOTOPE RATIO MS Astrum Glow Discharge MS Nu Plasma 1700 Multi-Collector ICP-MS Panorama HR Stable Isotope Ratio

More information

Kjeltec 2300 Analyzer Unit

Kjeltec 2300 Analyzer Unit Kjeltec 2300 Analyzer Unit Automatic distillation and approved colorimetric titration for analysis of Kjeldahl nitrogen/protein, ammonium- nitrogen, TKN, Direct distillation (DD), volatile acids/ bases

More information

HIGH PERFORMANCE LIQUID CHROMATOGRAPHY INSTRUMENTATION. Mrs. G. Aruna Mpharm (PhD) Dept. of PA & QA KTPC

HIGH PERFORMANCE LIQUID CHROMATOGRAPHY INSTRUMENTATION. Mrs. G. Aruna Mpharm (PhD) Dept. of PA & QA KTPC HIGH PERFORMANCE LIQUID CHROMATOGRAPHY INSTRUMENTATION Mrs. G. Aruna Mpharm (PhD) Dept. of PA & QA KTPC 1 HPLC INSTRUMENTATION CONSIST OF Solvent Reservoir( hplc solvent reservoir systems) Pumps Pre Guard

More information

Thermo Finnigan LTQ. Specifications

Thermo Finnigan LTQ. Specifications IET International Equipment Trading Ltd. www.ietltd.com Proudly serving laboratories worldwide since 1979 CALL +847.913.0777 for Refurbished & Certified Lab Equipment Thermo Finnigan LTQ Specifications

More information

CALYS 120 IS. ATEX documenting multifunction calibrator with high accuracy 0.006%

CALYS 120 IS. ATEX documenting multifunction calibrator with high accuracy 0.006% ATEX documenting multifunction calibrator with high accuracy 0.006% is the top instrument of our range of ATEX documenting multifunction calibrators. Description is the top instrument of our range of ATEX

More information

Atomic Absorption Spectrometer ZEEnit P series

Atomic Absorption Spectrometer ZEEnit P series Atomic Absorption Spectrometer ZEEnit P series Technical Data ZEEnit series Update 07/2014 OBue 1/ 5 ZEEnit P series Variable high-end AA Spectrometer with Deuterium and Zeeman Background Correction with

More information

Chapter content. Reference

Chapter content. Reference Chapter 7 HPLC Instrumental Analysis Rezaul Karim Environmental Science and Technology Jessore University of Science and Technology Chapter content Liquid Chromatography (LC); Scope; Principles Instrumentation;

More information

Figure 1. Structures for Vitamin B2 and Vitamin B1.

Figure 1. Structures for Vitamin B2 and Vitamin B1. CH 461 & CH 461H F 18 Name Experiment 2C Integrated Laboratory Experiment DETERMINATION OF RIBOFLAVIN: A COMPARISON OF TECHNIQUES PART C. HIGH PERFORMANCE LIQUID CHROMATOGRAPHY The purpose of this experiment

More information

Quad-Z 215 with Disposable Tips: Implementing the Use of ZipTips for the Purification of Biological Samples

Quad-Z 215 with Disposable Tips: Implementing the Use of ZipTips for the Purification of Biological Samples Quad-Z 215 with Disposable Tips: Implementing the Use of ZipTips for the Purification of Biological Samples Introduction Application Note 201 Joan Stevens, PhD and Kirby Reed (Gilson, Inc.) A ZipTip is

More information

Figure 1. Structures for Vitamin B2 and Vitamin B1.

Figure 1. Structures for Vitamin B2 and Vitamin B1. CH 461 & CH 461H F 15 Name Experiment 2C Integrated Laboratory Experiment DETERMINATION OF RIBOFLAVIN: A COMPARISON OF TECHNIQUES PART C. HIGH PERFORMANCE LIQUID CHROMATOGRAPHY The purpose of this experiment

More information

AUTOMATED CHROMATOGRAPHY SYSTEMS. Featuring EZ Prep

AUTOMATED CHROMATOGRAPHY SYSTEMS. Featuring EZ Prep AUTOMATED CHROMATOGRAPHY SYSTEMS Featuring EZ Prep CombiFlash EZ Prep built on a strong history of chromatography innovations The CombiFlash EZ Prep system is the latest innovation from Teledyne Isco.

More information

Finnigan LCQ Advantage MAX

Finnigan LCQ Advantage MAX www.ietltd.com Proudly serving laboratories worldwide since 1979 CALL +847.913.0777 for Refurbished & Certified Lab Equipment Finnigan LCQ Advantage MAX The Finnigan LCQ Advantage MAX ion trap mass spectrometer

More information

LC-2000Plus Series. High Performance Liquid Chromatograph

LC-2000Plus Series. High Performance Liquid Chromatograph LC-2000Plus Series High Performance Liquid Chromatograph LC-2000Plu The JASCO Corporation was founded in 1958 to produce optical spectroscopy products for University research departments. The experience

More information

Mercury Stack Monitor SM-4

Mercury Stack Monitor SM-4 Member of the envea Group Mercury Stack Monitor SM-4 Automatic continuous emission monitor (CEM) for mercury Continuous operation Sample dilution directly at stack - works with virtually any sample matrix

More information

Dissolution Automation: Basic Questionnaire.

Dissolution Automation: Basic Questionnaire. Dissolution Automation: Basic Questionnaire. In order to quote the most suitable automated Dissolution System we would like you to answer this questionnaire: 1. Do you want to work : a) On line (on line

More information

BOXA-II ON-STREAM X-RAY FLUORESCENCE ANALYZER. Technical Description Version 2 BGRIMM AUTOMATION

BOXA-II ON-STREAM X-RAY FLUORESCENCE ANALYZER. Technical Description Version 2 BGRIMM AUTOMATION BOXA-II ON-STREAM X-RAY FLUORESCENCE ANALYZER Technical Description Version 2 BGRIMM AUTOMATION, South 4th Ring Road West, Beijing, China TEL: +86(10)59069762 Fax: +86(10)68360101 Contents BGRIMM AUTOMATION

More information

25-OH VITAMIN D 3 AND 25-OH VITAMIN D 2 IN PLASMA BY UV / VIS FAST CODE Z19710

25-OH VITAMIN D 3 AND 25-OH VITAMIN D 2 IN PLASMA BY UV / VIS FAST CODE Z19710 25-OH VITAMIN D 3 AND 25-OH VITAMIN D 2 IN PLASMA BY UV / VIS FAST CODE Z19710 BIOCHEMISTRY Quantification of 25-hydroxyvitamin D 3 (25-hydroxycholecalciferol) in serum is the best established indicator

More information

883 Basic IC plus. The smallest Metrohm ion chromatograph

883 Basic IC plus. The smallest Metrohm ion chromatograph 883 Basic IC plus The smallest Metrohm ion chromatograph 883 Basic IC plus small but powerful 02 The 883 Basic IC plus completes the family of intelligent Metrohm ion chromatographs. Although it is the

More information

Analysis of Trace (mg/kg) Thiophene in Benzene Using Two-Dimensional Gas Chromatography and Flame Ionization Detection Application

Analysis of Trace (mg/kg) Thiophene in Benzene Using Two-Dimensional Gas Chromatography and Flame Ionization Detection Application Analysis of Trace (mg/kg) Thiophene in Using Two-Dimensional Gas Chromatography and Flame Ionization Detection Application Petrochemical Authors James D. McCurry and Bruce D. Quimby Agilent Technologies

More information

Karl-Fischer Titration the method for determining water

Karl-Fischer Titration the method for determining water Karl-Fischer Titration the method for determining water Quite some experienced analyst will be unpleasantly reminded by the pyridine smell, when hearing the name Karl Fischer. However, modern reagents

More information

ChromTech options for PAL systems

ChromTech options for PAL systems ChromTech options for PAL systems SPDE features full automation for dynamic sample extraction, desorption and analysis using the CTC Combi PAL. Most of our customers use SPDE for food and flavor research,

More information

JAPAN QUALITY. Automated Clinical Analyzer

JAPAN QUALITY. Automated Clinical Analyzer JAPAN QUALITY Automated Clinical Analyzer Higher test performance and operability with new functions The clinical analyzer in the next stage 1 The best to the requirements for functionality and usability

More information

Agilent 7500a Inductively Coupled Plasma Mass Spectrometer (ICP-MS)

Agilent 7500a Inductively Coupled Plasma Mass Spectrometer (ICP-MS) www.ietltd.com Proudly serving laboratories worldwide since 1979 CALL +1.847.913.0777 for Refurbished & Certified Lab Equipment Agilent 7500a Inductively Coupled Plasma Mass Spectrometer (ICP-MS) The Agilent

More information

LC800. Smart HPLC. Until now UHPLC From now Smart HPLC

LC800. Smart HPLC. Until now UHPLC From now Smart HPLC LC800 Smart HPLC Until now UHPLC From now Smart HPLC Smart HPLC Leads to Ultimate Performance Patent Pending S LC800 is a completely new and unique concept, designed for maximum performance in high resolution

More information

ICP-3000 Inductively Coupled Plasma Optical Emission Spectrometer

ICP-3000 Inductively Coupled Plasma Optical Emission Spectrometer Inductively Coupled Plasma Optical Emission Spectrometer Inductively Coupled Plasma Optical Emission Spectrometer Inductively Coupled Plasma Optical Emission Spectrometer is powerful simultaneous full

More information

PERSPECTIVE STABLE ISOTOPE RATIO MS

PERSPECTIVE STABLE ISOTOPE RATIO MS Attom High Resolution ICP-MS PERSPECTIVE STABLE ISOTOPE RATIO MS Nu Plasma II Multi-Collector ICP-MS Panorama HR Stable Isotope Ratio MS Astrum Glow Discharge MS Nu Plasma 1700 Multi-Collector ICP-MS Horizon

More information

Performance characteristics of the Agilent 1290 Infinity Quaternary Pump

Performance characteristics of the Agilent 1290 Infinity Quaternary Pump Performance characteristics of the Agilent 129 Infinity Quaternary Pump Technical Overview Author A.G.Huesgen Agilent Technologies, Inc. Waldbronn, Germany Abstract This Technical Overview presents Proof

More information

Thermo Scientific. Anion-Exchange Column. Determination of Inorganic Anions in Diverse Sample Matrices. Superior Chromatographic Performance

Thermo Scientific. Anion-Exchange Column. Determination of Inorganic Anions in Diverse Sample Matrices. Superior Chromatographic Performance CHROMATOGRAPHY Thermo Scientific Dionex IonPac AS Anion-Exchange Column Product Specifications The Thermo Scientific Dionex IonPac AS anion-exchange column is designed for the fast analysis of inorganic

More information

Peptide Isolation Using the Prep 150 LC System

Peptide Isolation Using the Prep 150 LC System Jo-Ann M. Jablonski and Andrew J. Aubin Waters Corporation, Milford, MA, USA APPLICATION BENEFITS The Prep 150 LC System, an affordable, highly reliable system for preparative chromatography, is suitable

More information

CALYS 80P. Field pressure calibrator with high accuracy 0.01%

CALYS 80P. Field pressure calibrator with high accuracy 0.01% Field pressure calibrator with high accuracy 0.01% CALYS 80P is a field pressure calibrator within CALYS range with high accuracy of 0.01%. Description CALYS 80P is a field pressure calibrator within CALYS

More information

Petrochemical. Transformer Oil Gas Analysis - TOGA

Petrochemical. Transformer Oil Gas Analysis - TOGA Petrochemical Transformer Oil Gas Analysis - TOGA www.dps-instruments.com The DPS TOGA GC Systems are designed to analyze oil from electrical insulation materials that may have decomposed under thermal,

More information

THE MEASUREMENT OF SOLAR ULTRAVIOLET SPECTRAL IRRADIANCE PROBLEMS & SOLUTIONS

THE MEASUREMENT OF SOLAR ULTRAVIOLET SPECTRAL IRRADIANCE PROBLEMS & SOLUTIONS THE MEASUREMENT OF SOLAR ULTRAVIOLET SPECTRAL IRRADIANCE PROBLEMS & SOLUTIONS INTRODUCTION In recent years, researchers involved in many unrelated scientific disciplines have acquired an interest in accurately

More information

OMCL Network of the Council of Europe QUALITY MANAGEMENT DOCUMENT

OMCL Network of the Council of Europe QUALITY MANAGEMENT DOCUMENT OMCL Network of the Council of Europe QUALITY MANAGEMENT DOCUMENT PA/PH/OMCL (11) 04 QUALIFICATION OF EQUIPMENT ANNEX 1: QUALIFICATION OF HPLC EQUIPMENT Full document title and reference Document type

More information

The end of. mass-speculation. MS Certified Vials Pre-cleaned and certified vials for mass spectrometry

The end of. mass-speculation. MS Certified Vials Pre-cleaned and certified vials for mass spectrometry The end of mass-speculation Pre-cleaned and certified vials for mass spectrometry Bonded, ultra-pure closures LC/MS and GC/MS Manufacturing the Ultimate Vial for Mass Spectrometry More than a quarter century

More information

BECKMAN COULTER QbD1200 Total Organic Carbon Analyzer Critical Measurements Made Simple

BECKMAN COULTER QbD1200 Total Organic Carbon Analyzer Critical Measurements Made Simple BECKMAN COULTER QbD1200 Total Organic Carbon Analyzer Critical Measurements Made Simple Reliable TOC measurements Stop throwing away your first rep. QbD1200 has virtually eliminated sample-to-sample carryover

More information

Agilent G2350A Atomic Emission Detector (AED)

Agilent G2350A Atomic Emission Detector (AED) Agilent G0A Atomic Emission Detector (AED) Specifications Elements Specifications Wavelength Minimum Detectable Selectivity Dynamic Measurement Group Element(s) (nm) Level (pg/sec) Over Carbon Range Compound

More information

GPC/SEC Practical Tips and Tricks. Thomas Dent Applications Scientist Agilent Technologies. October, 2011 Gulf Coast Conference

GPC/SEC Practical Tips and Tricks. Thomas Dent Applications Scientist Agilent Technologies. October, 2011 Gulf Coast Conference GPC/SEC Practical Tips and Tricks Thomas Dent Applications Scientist Agilent Technologies October, 2011 Gulf Coast Conference 1 Section 1: Introduction Goals Brief introduction to GPC/SEC Highlight considerations

More information

Agilent s New Weak Anion Exchange (WAX) Solid Phase Extraction Cartridges: SampliQ WAX

Agilent s New Weak Anion Exchange (WAX) Solid Phase Extraction Cartridges: SampliQ WAX Agilent s New Weak Anion Exchange (WAX) Solid Phase Extraction Cartridges: SampliQ WAX Technical Note Agilent s SampliQ WAX provides Applications for strongly acidic, acidic and neutral compounds Excellent

More information

for Single mixing applications

for Single mixing applications RAPID KINETICS AND SPECTROSCOPY SFM-20 2 SYRINGE STOPPED-FLOW SYSTEM for Single mixing applications The SFM-20 is a high performance, modular stopped-flow system, designed for single mixing rapid kinetics

More information

Defining quality standards for the analysis of solid samples

Defining quality standards for the analysis of solid samples Defining quality standards for the analysis of solid samples Thermo Scientific Element GD Plus Glow Discharge Mass Spectrometer Redefine your quality standards for the elemental analysis of solid samples

More information

MultiVap8: Automated concentration system

MultiVap8: Automated concentration system MultiVap8: Automated concentration system Introduction Solvent evaporation is an essential step of sample preparation before chromatographic analysis and is commonly used in a variety of applications including

More information

separation of the cleaned extract in subgroups of compounds (PCDDs, PCDFs, PCBs) depending on their polarity and geometry. The fractions can then be a

separation of the cleaned extract in subgroups of compounds (PCDDs, PCDFs, PCBs) depending on their polarity and geometry. The fractions can then be a ONE STEP CLOSER TO A COOK BOOK METHOD FOR DIOXIN ANALYSIS PART 1: THE PROCEDURE Focant JF 1, Shirkhan H 2, Patterson Jr DG 3 1 CART, Organic and Biological Analytical Chemistry, Mass Spectrometry Laboratory,

More information

ACETONE IN URINE BY UV CODE Z42010

ACETONE IN URINE BY UV CODE Z42010 ACETONE IN URINE BY UV CODE Z42010 BIOCHEMISTRY Acetone is a colorless, mobile, flammable liquid. It is readly soluble in water, ethanol, ether etc., and itself serves as an important solvent. Acetone

More information

Dionex IonPac AS28-Fast-4µm column

Dionex IonPac AS28-Fast-4µm column CHROMATOGRAPHY Thermo Scientific Dionex IonPac AS-Fast-4µm Columns Product Specifications The Thermo Scientific Dionex IonPac AS-Fast-4µm column is a high-capacity, hydroxide-selective anionexchange column

More information

CHROMATOGRAPHY. The term "chromatography" is derived from the original use of this method for separating yellow and green plant pigments.

CHROMATOGRAPHY. The term chromatography is derived from the original use of this method for separating yellow and green plant pigments. CHROMATOGRAPHY The term "chromatography" is derived from the original use of this method for separating yellow and green plant pigments. THEORY OF CHROMATOGRAPHY: Separation of two sample components in

More information

Determination of trace anions in concentrated hydrofluoric acid

Determination of trace anions in concentrated hydrofluoric acid APPLICATION NOTE 78 Determination of trace anions in concentrated hydrofluoric acid Authors Archava Siriraks Thermo Fisher Scientific, Sunnyvale, CA Keywords HF, ICS-5000 +, IonPac AS10, IonPac AC10, ion

More information

S2 PICOFOX. Innovation with Integrity. Spectrometry Solutions TXRF

S2 PICOFOX. Innovation with Integrity. Spectrometry Solutions TXRF S2 PICOFOX Spectrometry Solutions Innovation with Integrity TXRF S2 PICOFOX True Trace Analysis with XRF for the First Time! You need to know the concentration of trace elements in environmental samples?

More information

high performance OPTIC 3 and applications a total analytical solution

high performance OPTIC 3 and applications a total analytical solution high performance OPTIC 3 and applications a total analytical solution Excellent by nature Excellent effectivity, efficient performance and great flexibility. OPTIC 3: a fully programmable injector for

More information

LC Technical Information

LC Technical Information LC Technical Information Method Transfer to Accucore.6 μm Columns Containing solid core particles, which are engineered to a diameter of.6μm and a very narrow particle size distribution; Accucore HPLC

More information

Application Note. Pharmaceutical QA/QC. Author. Abstract. Siji Joseph Agilent Technologies, Inc. Bangalore, India

Application Note. Pharmaceutical QA/QC. Author. Abstract. Siji Joseph Agilent Technologies, Inc. Bangalore, India Reducing analysis time and solvent consumption for isocratic USP assay methods with current and proposed USP guidelines using the Agilent 129 Infinity LC System An efficient way to reduce cost of analysis

More information

MALVERN ADVANCED GPC/SEC DETECTORS SETTING THE STANDARD MOLECULAR WEIGHT MOLECULAR SIZE MOLECULAR STRUCTURE

MALVERN ADVANCED GPC/SEC DETECTORS SETTING THE STANDARD MOLECULAR WEIGHT MOLECULAR SIZE MOLECULAR STRUCTURE MOLECULAR WEIGHT MOLECULAR SIZE MOLECULAR STRUCTURE MALVERN ADVANCED GPC/SEC DETECTORS SETTING THE STANDARD Setting the Standard WHAT CAN ADVANCED GPC/SEC DETECTION OFFER YOU? A modern research environment

More information

Automation of Routine Microplate Pipetting and Dispensing

Automation of Routine Microplate Pipetting and Dispensing Automation of Routine Microplate Pipetting and Dispensing Quantitative assays of all sorts are common to many applications in basic science and clinical research. Most of these assays require the movement,

More information

ADI 2040 Process Analyzer

ADI 2040 Process Analyzer ADI 2040 Process Analyzer Multi-purpose wet chemical analysis Multi-purpose Wet Chemical Analysis ADI 2040 The Metrohm Applikon ADI 2040 Process Analyzer is a multipurpose wet chemical analyzer, that has

More information

Thermo Scientific ICP-MS solutions for the semiconductor industry. Maximize wafer yields with ultralow elemental detection in chemicals and materials

Thermo Scientific ICP-MS solutions for the semiconductor industry. Maximize wafer yields with ultralow elemental detection in chemicals and materials Thermo Scientific ICP-MS solutions for the semiconductor industry Maximize wafer yields with ultralow elemental detection in chemicals and materials Trace impurity analysis in chemicals an used in the

More information

Determination of Pesticides in Aqueous Samples by On-Line Coupling Solid-Phase Extraction to Gas Chromatography with At-Column Concentrating Interface

Determination of Pesticides in Aqueous Samples by On-Line Coupling Solid-Phase Extraction to Gas Chromatography with At-Column Concentrating Interface Application Note No. 033 Determination of Pesticides in Aqueous Samples by On-Line Coupling Solid-Phase Extraction to Gas Chromatography with At-Column Concentrating Interface Ryoichi Sasano*, Takayuki

More information

Luminescence transitions. Fluorescence spectroscopy

Luminescence transitions. Fluorescence spectroscopy Luminescence transitions Fluorescence spectroscopy Advantages: High sensitivity (single molecule detection!) Measuring increment in signal against a dark (zero) background Emission is proportional to excitation

More information

Ch.28 HPLC. Basic types of Liquid Chromatography Partition (LLC) Adsorption (LSC) Ion Exchange (IC) Size Exclusion (SEC or Gel Chromatography)

Ch.28 HPLC. Basic types of Liquid Chromatography Partition (LLC) Adsorption (LSC) Ion Exchange (IC) Size Exclusion (SEC or Gel Chromatography) Ch.28 HPLC 28.1 Basic types of Liquid Chromatography Partition (LLC) Adsorption (LSC) Ion Exchange (IC) Size Exclusion (SEC or Gel Chromatography) High Performance (Pressure) LC Glass column st.steel (high

More information