YMC-Triart Prep. Robust Improved particle properties result in better chromatographic performance
|
|
- Melina Powell
- 6 years ago
- Views:
Transcription
1 YMC-Triart Prep Robust and ph stable hybrid silica process material The Selectivity Company Robust Improved particle properties result in better chromatographic performance Flexible Chemical stability ph 1-12 Durable against alkaline CIP Economic Purify more endproduct on less stationary phase
2 2 YMC-Triart Prep Particle Technology... page 3 Physicochemical Characteristics... page 4-5 Mechanical Stability... page 6 Comparing YMC-Triart Prep C18-S to competitor material... page 7 Cleaning-in-place (CIP)... page 8-9 Applications... page 10 Ordering Information... page 11
3 3 YMC-Triart Prep With YMC-Triart Prep, a ph stable preparative grade HPLC stationary phase gets available. It is produced in lot sizes of up to several hundred kg. This innovative multi-layer hybrid material sets a new benchmark for RP HPLC phases. It is well suited for production scale applications, as it is available up to multi-ton scale. YMC-Triart Prep is chemically stable up to ph This provides more flexibility for method development and allows for more efficient cleaning-in-place (CIP) procedures. From real life process development work YMC-Triart Prep has shown to outperform traditional silicabased materials 2- to 4-fold in terms of durability. Longer column lifetimes lead to more kilogram of product produced per kilogram of stationary phase. The results are: improved production procedures and reduced overall costs. Particle technology YMC-Triart Prep is a multilayered material prepared from a well-controlled particle formation process which is adapted from micro-reactor technology. The recently developed production step results in truly narrow particle and pore size distributions! With YMC-Triart Prep otherwise, challenging ph and high temperature conditions are no longer a limitation even to the day-to-day work in laboratories or production. Most importantly, due to its unique particle composition, a balanced hydrophobicity and silanol activity are achieved which makes YMC-Triart Prep a First Choice material in method development! YMC-Triart Prep hybrid structure inorganic siloxane layer organic siloxane layer
4 4 Specification Base material YMC-Triart Prep C18-S YMC-Triart Prep C8-S inorganic/organic multi-layered hybrid Particle size [µm] 10,15, 20 10, 15, 20 Pore size [nm] Specific surface area [m 2 /g] Bonding polymeric C18 polymeric C8 End-capping yes yes ph range 1.0 ~ ~ 12.0 Homogeneous and uniform particles* YMC-Triart (12 nm, 5 µm) YMC-Triart Prep (20 nm, 15 µm) X-Bridge HILIC ( TM of Waters Corp.) (13.5 nm, 5 µm) YMC-Triart Prep is produced using micro-reactor technology in the granulation process. The results are spherical particles with a highly uniform particle and pore size distribution. This leads to a reduction of the back-pressure and to more reproducibility in surface modification. * by courtesy of YMC Co., Ltd.
5 5 Excellent ph stability Acidic condition (ph 1, 70 C) Alkaline condition (ph 11.5, 50 C) (%) of initial retention The columns are stored in acetonitrile/water/tfa (10/90/1) 70 C, and the performance tested every 20 hours Time (hr) YMC-Triart Prep C18-S, 15 µm Kromasil C18, 16 µm (Kromasil) ODS-AP, 15 µm (Daiso) Chromatorex C18, 15 µm (Fuji) (%) of initial theoretical plate Chromatorex C18, 15 µm (Fuji) ODS-AP, 15 µm (Daiso) Kromasil C18, 16 µm, Kromasil YMC-Triart Prep C18-S, 15 µm Time (hr) Column: 250 x 6.0 mm ID Eluent: acetonitrile / water (60/40) Flow rate: 1.7 ml/min Temperature: 37 C Detection: UV at 254 nm Sample: butyl benzoate Column: 150 x 4.6 mm ID Eluent: 50 mm TEA in methanol / 50 mm TEA in water (ph 11.5) (20/80, v/v) Flow rate: 1.0 ml/min Detection: UV at 254 nm Sample: caffeine At high ph YMC-Triart Prep C18-S shows lifetimes of up to 4 times longer compared to conventional silica materials. This enables new separations at high ph which are not possible with silica material. Furthermore, the material can endure more CIP-cycles than conventional phases used in industrial processes (see page 8). Advantages of YMC-Triart Prep YMC-Triart Prep ph-stability 1-12 Chemical and mechanical stability Uniform particle size Narrow pore size distribute Your benefit Flexibility Method development Durable against CIP-conditions Cost savings High production throughput Improved packing = improved chromatographic performance High loadability Application Data by courtesy of YMC Co., Ltd.
6 6 Mechanical stability test Test procedure 1. Column packing Column: DAU Bed length: 100 x 50 mm ID Pressure: 6.5 MPa 2. Pressure measurement Eluent: methanol / water (85/15) Flow rate: 50 ml/min Temperature: ambient 3. Unpacking Psi/m 2000 Mechanical stability (dynamic) Packing number YMC-Triart Prep (10 µm, 20 nm) (Hybrid silica) YMC HG-series (10 µm, 20 nm) (High grade silica) Traditional Silica (10 µm, 20 nm) Shearing and crushing of silica particles leads to the formation of fines, which results in an increased backpressure. By using mechanically stable, spherical particles the formation of fines can be reduced. Here, high mechanical stability of YMC-Triart Prep is demonstrated by means of repeated packing of a DAC column. Even after more than 10 repacking cycles for the same material the pressure does not increase. The absence of fines is proven by a constant backpressure. This makes YMC-Triart Prep a valuable asset for method development and especially for process optimisation!
7 7 YMC Triart Prep C18-S vs. competitor material (client data*) Client data confirms that YMC-Triart Prep C18-S shows retention for hydrophobic compounds comparable to conventional silica materials. At the same time polar molecules are exceptionally well separated. * Client data shows non-optimized scouting runs performed on the respective C18 material packed into 250 x 4.6 mm ID columns. Narrow pore distribution 4500 d Vp/ d logd YMC-Triart Prep Conventional silica-based particle X-Bridge HILIC Pore size (nm) A narrow pore size distribution of a stationary phase beneficially affects peak width and sample loading in liquid chromatography. Where micropores account for an artificially high surface area of a stationary phase but are mostly inaccessible to target molecules, mesopores decreases the column efficiency due to a steric hindrance effect, which significantly slows mass transfer. YMC-Triart Prep C18-S exhibits a narrower pore size distribution with fewer micro- and mesopores. This results in improved peak shapes and higher sample loading in your preparative processes. Application Data by courtesy of YMC Co., Ltd.
8 8 Cleaning-in-place (CIP) Test procedure Sample injection (insulin in human serum) injected 20 times Regeneration with alkaline solution Wash with alkaline solution 0.1 M NaOH / acetonitrile (50/50) 10 CV Neutralisation and wash with organic solvent 1. acetonitrile / water (20/80) 2. acetonitrile / water (90/10) CIP performance of YMC-Triart Prep C8-S Effect of CIP with alkaline solution Durability under repeated CIP Column: YMC-Triart Prep C8-S (20 nm, 10 µm) 250 x 4.6 mm ID Eluent: A) water / TFA (100/0.1) B) acetonitrile / TFA (100/0.1) 28-35% B (0-15 min) Flow rate: 1.0 ml/min Temperature: 25 C Detection: UV at 220 nm Injection: 30 µl Sample: 10 mg/ml insulin bovine + human serum (2:1) Application Data by courtesy of YMC Co., Ltd.
9 9 CIP performance of YMC-Triart Prep C8-S YMC-Triart Prep C8-S (10 µm, 20 nm) Silica based C8 material (10 µm, 20 nm) Column: 50 x 4.6 mm ID Eluent: A) water / TFA (100/0.1) B) acetonitrile / TFA (100/0.1) 29-36% B (0-2 min), 36% B (2-3 min), 29% B (3-6 min) Flow rate: 1.0 ml/min Temperature: 25 C Detection: UV at 220 nm Injection: 6 µl Sample: 10 mg/ml insulin bovine + human serum (2:1) Column lifetime extended by factor > 2 In production repeated injections of a solution of insulin in human plasma/serum are carried out. Consequently, absorption of protein and other impurities to the surface of the packing material reduces the retention capacity of the column. Methodology: At this point a wash step with an alkaline solution (e.g. 0.1 M NaOH) removed the impurities and restores the full capacity of the column. Problem: Silica materials are unsuitable for alkaline wash conditions, because of their poor durability at high ph. Solution: Hybrid silica based YMC-Triart Prep has an excellent durability at high ph. It is amenable to alkaline wash conditions and thus enables longer column lifetime. This in turn reduces production costs: Lower consumption of packing material and fewer downtimes due to column repacking. An extension of column lifetime by a factor of > two has been achieved! Application Data by courtesy of YMC Co., Ltd.
10 10 Structurally similar peptides at ph > 7 Easy separation ph-shift Column: YMC-Pack Polymer C18, 250 x 4.6 mm ID Eluent: acetonitrile / water / TFA (18/82/0.05) (ph 2.2) Flow rate: 0.5 ml/min Detection: UV at 220 nm Injection: 10 µl Sample: 1. Angiotensin III 2. Angiotensin II 3. Angiotensin I Column: YMC-Triart Prep C8-S (20 nm, 10 µm) 250 x 4.6 mm ID Eluent: A) acetonitrile / 10 mm NH 4 H 2 PO 4 + NH 4 OH (50/50) (ph 2.2) B) 10 mm NH 4 H 2 PO 4 + NH 4 OH (ph 7) Gradient: 35-65% A in 25 min Flow rate: 1 ml/min Detection: UV at 215 nm Injection: 10 µl Sample: 1. Angiotensin II 2. Angiotensin III 3. Angiotensin I Methods developed on analytical YMC-Triart material are readily transferred to preparative conditions. Thus, YMC-Triart Prep is equally suitable for industrial scale purifications and in process controlls. Robust Improved particle properties result in better chromatographic performance Flexible Chemical stability ph 1-12 Durable against alkaline CIP Economic Purify more endproduct on less stationary phase Application Data by courtesy of YMC Co., Ltd.
11 11 Ordering information YMC-Triart Prep, preparative bulk media Pore size (nm) 12 YMC-Triart Prep C18-S Particle size (µm) Product Code 10 TAS12S11 Pore size (nm) YMC-Triart Prep C8-S Particle size (µm) Product Code 10 TOS20S11 15 TAS12S TOS20S16 20 TAS12S21 20 TOS20S21 Typical pack sizes: Laboratory scale: 100 g - 5 kg PE bottle Industrial scale: 5 kg - 50 kg in double lined PE bags inside metal drum Larger pack sizes on request Other particle and pore size combinations on request. Examples of existing customised material: TAS08S11, TOS12S11 Other available brochures: YMC*Gel HG-series High grade silica phases for preparative HPLC The Selectivity Company YMC*Gel HG-series brochure General purpose preparative phases on high grade silica base. Available as silica or with C18, C8, C4, C1, phenyl, cyano, amino or diol bonding. Particle size: 10 µm, 15 µm, 20 µm, 50 µm Pore size: 8 nm, 12 nm, 20 nm, 30 nm YMC-BioPro prep brochure YMC-BioPro IEX materials Polymeric ion exchange material for biochromatography. Available as strong anion- or cation-exchanger. Excellent flow properties and high dynamic binding capacity. Prep Bulk media Extremely economic in industrial scale applications.
12 Your local distributor: Co., Ltd. YMC Karasuma-Gojo Bld. 284 Daigo-cho, Karasuma Nisiiru Gojo-dori Shimogyo-ku, Kyoto Japan TEL. +81(0) , FAX +81(0) Europe GmbH Schöttmannshof 19 D Dinslaken Germany TEL. +49(0)2064/427-0, FAX +49(0)2064/ Taiwan Co., Ltd. 3F, No. 1353, Zhongzheng Rd., Taoyuan City, Taoyuan Country 330, Taiwan (R.O.C.) TEL , FAX America, Inc. 941 Marcon Boulevard Suite 201 Allentown, PA18109 USA TEL , FAX Korea Co., Ltd. #208, Owners Tower, 16-5, Sunae-dong, Bundang-gu, Seongnam-si, Gyeonggi-do, Korea TEL , FAX India Ltd. CX - 07, 3rd Floor, Lobe - 1, A-Towers, The Corenthum, Plot No- A-41, Sector - 62, Noida (U.P.) India. TEL. +91(0) , FAX +91(0) Co., Ltd. Shanghai Rep. Office Far East International Plaza A2404 No. 319 Xianxia Road, Shanghai P.R. China TEL: , FAX:
YMC-Triart Prep. Robust Improved particle properties result in better chromatographic performance
Robust and ph stable hybrid silica process material The Selectivity Company Robust Improved particle properties result in better chromatographic performance Flexible Chemical stability ph 2-10 Durable
More informationStationary phases for prep LC
The Selectivity Company Versatile hybrid silica-based Stationary phases for prep LC YMC-Triart Prep Stability Reliability ph stable www.ymc.de 2 Contents 3 page Introduction...4-8 How to Make the Correct
More informationLC Technical Information
LC Technical Information Method Transfer to Accucore.6 μm Columns Containing solid core particles, which are engineered to a diameter of.6μm and a very narrow particle size distribution; Accucore HPLC
More informationProduct Bulletin. ACE LC/MS and Rapid Analysis HPLC Columns. HPLC Columns
Product Bulletin HPLC Columns ACE LC/MS and Rapid Analysis HPLC Columns 0 mm, 30 mm, 35 mm and 50 mm column lengths.0,., 3.0, 4.0 and 4.6 mm column diameters Configured for High Sample Throughput Specially
More informationPackings for HPLC. Packings for HPLC
Summary of packings for HPLC In analytical HPLC, packings with particle sizes of 3 to 10 µm are preferred. For preparative separation tasks, also particles with diameters larger than 10 µm are applied.
More informationApplications and Properties of New Polymeric Mixed Mode Cation Exchange Chromatography Media
Applications and Properties of New Polymeric Mixed Mode Cation Exchange Chromatography Media Nandu Deorkar*, Wei Guo, Bob Buss, Joe Mladosich and Paul Bouis Mallinckrodt Baker Inc. 1904 J.T. Baker Way
More informationAdvantages of polymerbased. an alternative for ODS
Advantages of polymerbased HPLC columns an alternative for ODS Yukiko Higai Shodex, 1 Content (1) Comparison between Silica and Polymer-based RP columns (2) Characteristics of Polymer RP columns - an example:
More informationHPLC Column Material - Bulk Ware
HPLC Column Material - Bulk Ware Constantly growing demands on separation efficiency and availability of solid phase material for packing HPLC columns and column packing stations have motivated us to provide
More informationQUALITY HPLC COLUMNS PARTICLE PORE PAGE SIZE SIZE. C18 Bidentate C18 Extremely long column life and rugged 4um 100Å 3
Cogent HPLC Columns Manufactured by Table of Contents QUALITY HPLC COLUMNS PARTICLE PORE PAGE SIZE SIZE C18 Bidentate C18 Extremely long column life and rugged 4um 100Å 3 C8 Bidentate C8 Extremely long
More informationThermo Scientific Accucore XL HPLC Columns. Technical Manual
Thermo Scientific Accucore XL HPLC Columns Technical Manual Thermo Scientific Accucore XL HPLC Columns Based on Core Enhanced Technology using µm solid core particles, Accucore XL HPLC columns allow users
More informationOptical Isomer Separation Columns and Packing Materials
02 Optical Isomer Separation s and Packing Materials CHIRAL ART----------------------------------- 26~29 YMC CHIRAL NEA (R), (S)-----------------------30 YMC CHIRAL CD BR------------------------------31
More informationEternity. Kromasil EternityXT. Designed for extended lifetime
Eternity Kromasil EternityXT Designed for extended lifetime Easy handling of tough demands Kromasil Eternity was introduced a few years ago, for analytical HPLC. K romasil EternityXT is an extension of
More informationOptimisil HPLC & UPLC Column catalogue
Optimisil HPLC & UPLC Column catalogue Analytical Hub Plot No: 37, P & T Colony, Vikrampuri, Secunderabad 500009 Tel: 040-64621313, Mobile: +91 7799931313 Website: www.analyticalhub.com email: contact@analyticalhub.com
More informationShodex TM ODP2 HP series columns
HPLC Columns Shodex TM ODP2 HP series columns Better retention of highly polar substances Technical notebook No. 6 Contents 1. Introduction 1-1. Specifications 1-2. Eluent Compatibility of ODP2 HP Series
More informationAgilent s New Weak Anion Exchange (WAX) Solid Phase Extraction Cartridges: SampliQ WAX
Agilent s New Weak Anion Exchange (WAX) Solid Phase Extraction Cartridges: SampliQ WAX Technical Note Agilent s SampliQ WAX provides Applications for strongly acidic, acidic and neutral compounds Excellent
More informationPart 2. Overview of HPLC Media
Part 1. General Chromatographic Theory Part 2. Overview of HPLC Media Part 3. The Role of the Mobile Phase in Selectivity Part 4. Column Care and Use 1 HPLC Particle Technology Core-Shell Particle Fully
More informationOrosil HPLC Columns. OroSil HPLC columns are designed for the separation of polar, semi-polar, and nonpolar compounds at low to medium ph.
Orosil OroSil HPLC columns are designed for the separation of polar, semi-polar, and nonpolar compounds at low to medium ph. Excellent organic base selectivity with very low asymmetry values Compatible
More informationMethod Development with ZirChrom's Ion Exchange Phases
For Peak Performance ZIRCHROM ION EXCHANGERS Phases for Sugars and Proteins Wide Range of Ion Exchange Selectivity No Shrinking or Swelling Use Any Organic Solvent Significantly Higher Efficiency than
More informationExtraction of Methylmalonic Acid from Serum Using ISOLUTE. SAX Prior to LC-MS/MS Analysis
Application Note AN89.V.1 Extraction of Methylmalonic Acid from Serum Using ISOLUTE SAX Page 1 Extraction of Methylmalonic Acid from Serum Using ISOLUTE SAX Prior to LC-MS/MS Analysis Sample Preparation
More informationTLC. Thin Layer Chromatography. State-of-the-art TLC products. Quality Efficiency Selectivity.
TLC Thin Layer Chromatography State-of-the-art TLC products Quality Efficiency Selectivity www.mn-net.com MACHEREY-NAGEL Thin Layer Chromatography for more than 5 decades Why TLC? Fast and cost-saving
More informationAnalysis of Metals, Halides, and Inorganic Ions Using Hydrophilic Interaction Chromatography
Application Note Inorganic Ions, Water Testing, Minerals, Metals, Basic Chemicals Analysis of Metals, Halides, and Inorganic Ions Using Hydrophilic Interaction Chromatography Authors Anne Mack, Adam Bivens
More informationInertSustainSwift C8
HPLC, LC/MS Columns InertSustainSwift TM C8 New! InertSustainSwift C8 is an octyl group (C8) bonded column offering the same extreme inertness to any type of compounds just like InertSustainSwift C8, which
More informationzorbax Packed by Phenomenex Material Characteristics High efficiency Guaranteed quality Phenomenex columns packed with Zorbax
Packed by Phenomenex High efficiency Guaranteed quality Phenomenex columns packed with 7 μm materials offer the advantages of lower cost as well as lower operating backpressures, which result in long column
More information( )( ) Selectivity Choices in Reversed-Phase Fast LC. Introduction. R s = 1 a 1 k 4 a 1 + k
Selectivity Choices in Reversed-Phase Fast LC Luisa Pereira, Monica Dolci, Thermo Fisher Scientific, Runcorn, Cheshire, UK Technical Note 20543 Key Words Accucore, Hypersil GOLD, Syncronis, Column Chemistry,
More informationviridis Columns Bringing a New Dimension to SFC Combining state-of-the-art media manufacturing with industry leading column technology, Viridis
[ viridis columns ] viridis Columns Bringing a New Dimension to SFC Combining state-of-the-art media manufacturing with industry leading column technology, Viridis Supercritical Fluid Chromatography (SFC)
More informationfor Acclaim Mixed-Mode HILIC-1 Column
for Acclaim Mixed-Mode HILIC-1 Column Product Manual for ACCLAIM Mixed-Mode HILIC-1 Page 1 of 17 Product Manual for ACCLAIM Mixed-Mode HILIC-1 Column 5µm, 4.6 x 250mm, P/N 066844 5µm, 4.6 x 150mm, P/N
More informationLC and LC/MS Column Selection Flow Chart
LC and LC/MS Column Selection Flow Chart To use the column selection diagram below, simply follow the path for your analyte and mobile phase. At the far right, follow your final column selection to the
More informationHICHROM. Chromatography Columns and Supplies. LC COLUMNS SeQuant ZIC-HILIC. Catalogue 9. Hichrom Limited
HICHROM Chromatography Columns and Supplies LC COLUMNS SeQuant ZIC-HILIC Catalogue 9 The Markham Centre, Station Road Theale, Reading, Berks, RG7 PE, UK Tel: + (0)8 90 660 Fax: + (0)8 9 8 Email: sales@hichrom.co.uk
More informationGuide to Choosing and Using Polymer Reversed Phase Columns!
Guide to Choosing and Using Polymer Reversed Phase Columns! Choosing the best RP Column to use: Silica is normally used as the packing material for HPLC columns for a number of reasons. It is very strong,
More informationHigh Performance Liquid Chromatography
Updated: 3 November 2014 Print version High Performance Liquid Chromatography David Reckhow CEE 772 #18 1 HPLC System David Reckhow CEE 772 #18 2 Instrument Basics PUMP INJECTION POINT DETECTOR COLUMN
More informationHigh Performance Liquid Chromatography
Updated: 3 November 2014 Print version High Performance Liquid Chromatography David Reckhow CEE 772 #18 1 HPLC System David Reckhow CEE 772 #18 2 1 Instrument Basics PUMP INJECTION POINT DETECTOR COLUMN
More informationAlltech Alltima HP Introduction
Alltech Introduction High-Stability, High-Purity, High-Performance, Low-Bleed Columns for Demanding Applications Better Peak Symmetry high-purity silica eliminates peak tailing problems Long Column Life
More informationHICHROM. Chromatography Columns and Supplies. LC COLUMNS Zorbax. Catalogue 9. Hichrom Limited
HICHROM Chromatography Columns and Supplies LC COLUMNS Zorbax Catalogue 9 1 The Markham Centre, Station Road Theale, Reading, Berks, RG7 4PE, UK Tel: +44 (0)118 930 3660 Fax: +44 (0)118 932 3484 Email:
More informationHICHROM. Chromatography Columns and Supplies. LC COLUMNS SIELC Primesep. Catalogue 9. Hichrom Limited
HICHROM Chromatography Columns and Supplies LC COLUMNS SIELC Primesep Catalogue 9 The Markham Centre, Station Road Theale, Reading, Berks, RG7 4PE, UK Tel: +44 (0)8 90 660 Fax: +44 (0)8 9 484 Email: sales@hichrom.co.uk
More informationReversed Phase Solvents
Part 1. General Chromatographic Theory Part 2. verview of HPLC Media Part 3. The Role of the Mobile Phase in Selectivity Part 4. Column Care and Use Reversed Phase Solvents 2 Solvents for RP Chromatography
More informationUptisphere CS Evolution Core Shell columns for fast & highly efficient identification & quantification of small molecules
Uptisphere CS Evolution Core Shell columns for fast & highly efficient identification & quantification of small molecules www.interchim.com www.blog.interchim.com www.forum.interchim.com www.facebook.com/interchim
More informationSample Preparation TLC Plates
TLC PLATES TLC Plates Economical separation method High sample throughput Pilot procedure for HPLC and flash chromatography Versatile range of ready-to-use layers Thin layer chromatography (TLC) is a simple,
More informationChemistry Instrumental Analysis Lecture 28. Chem 4631
Chemistry 4631 Instrumental Analysis Lecture 28 High Performance Liquid Chromatography () Instrumentation Normal Phase Chromatography Normal Phase - a polar stationary phase with a less polar mobile phase.
More informationPacked Column for Ultra-Fast Reversed-Phase Liquid Chromatography, TSKgel Super-ODS. Table of Contents
No. 089 SEPARATION REPORT Packed Column for Ultra-Fast Reversed-Phase Liquid Chromatography, TSKgel Super-ODS Table of Contents 1. Introduction 1 2. Column Specification 1 3. Features of Packing Materials
More informationACE Excel SuperC18. ACE UHPLC and HPLC Columns. Ultra-Inert UHPLC and HPLC Columns with Extended ph Stability
ACE Excel SuperC8 TM Ultra-Inert UHPLC and HPLC s with Extended ph Stability Exploit selectivity at low, intermediate and high ph Use with LC/MS-compatible buffers between ph.. High efficiency µm, µm,
More informationHICHROM. Chromatography Columns and Supplies. LC COLUMNS Vydac. Catalogue 9. Hichrom Limited
HICHROM Chromatography Columns and Supplies LC COLUMNS Vydac Catalogue 9 The Markham Centre, Station Road Theale, Reading, Berks, RG PE, UK Tel: + (0)8 90 660 Fax: + (0)8 9 8 Email: sales@hichrom.co.uk
More informationBringing uhplc Performance to the Separation of Peptides
P e p t i d e E S - C 1 8 U H P L C C o l u m n s Bringing uhplc Performance to the Separation of Peptides Compatible with UHPLC and conventional HPLC equipment. Sumpfstr. 3, CH-6300 Zug; Fax: 041 748
More informationSuperose High-performance Columns
GE Healthcare Life Sciences Data file 18-1163-8 AC Gel filtration Superose High-performance Columns Superose prepacked columns are designed for highperformance, laboratory-scale separations of proteins
More informationHPLC Winter Webinars Part 2: Sample Preparation for HPLC
HPLC Winter Webinars Part 2: Sample Preparation for HPLC Jon Bardsley, Application Chemist Thermo Fisher Scientific, Runcorn/UK The world leader in serving science What am I Going to Talk About? What do
More informationEternity. Kromasil EternityXT. Designed for extended lifetime
Eternity Kromasil EternityXT Designed for extended lifetime Easy handling of tough demands Kromasil Eternity was introduced a few years ago, for analytical HPLC. K romasil EternityXT is an extension of
More informationACE SuperC18. ACE UHPLC and HPLC Columns. Ultra-Inert UHPLC and HPLC Columns with Extended ph Stability
ACE SuperC8 TM Ultra-Inert UHPLC and HPLC s with Extended ph Stability Exploit selectivity at low, intermediate and high ph Use with LC/MS compatible buffers between ph.. High efficiency µm, µm, µm and
More informationInertSustainSwift C8
Physical Properties Silica Particle Size Surface Area Pore Size Pore Volume Bonded Phase End-capping Carbon Loading ph Range USP Code :ES (Evolved Surface) Silica Gel :.9 μm, μm, μm :00 m /g :00 Å (0 nm)
More informationHICHROM. Chromatography Columns and Supplies. LC COLUMNS HALO and HALO-5. Catalogue 9. Hichrom Limited
HICHROM Chromatography Columns and Supplies LC COLUMNS HALO and HALO- Catalogue 9 The Markham Centre, Station Road Theale, Reading, Berks, RG PE, UK Tel: + (0)8 90 0 Fax: + (0)8 9 8 Email: sales@hichrom.co.uk
More informationGemini-NX Performance paired with Axia Technology
Si Si Si Si Si Si Si C Si Si Si Si Si Gemini-NX Performance paired with Axia Technology Gemini -NX Axia Packed Technology Improves Yield, Throughput, and Column Lifetime Ideal Purification Platform While
More informationBasic Principles for Purification Using Supercritical Fluid Chromatography
Basic Principles for Purification Using Supercritical Fluid Chromatography Jo-Ann M. Jablonski, Christopher J. Hudalla, Kenneth J. Fountain, Steven M. Collier, and Damian Morrison Waters Corporation, Milford,
More informationBiochemistry. Biochemical Techniques HPLC
Description of Module Subject Name Paper Name 12 Module Name/Title 13 1. Objectives 1.1. To understand the basic concept and principle of 1.2. To understand the components and techniques of 1.3. To know
More informationPeptide Isolation Using the Prep 150 LC System
Jo-Ann M. Jablonski and Andrew J. Aubin Waters Corporation, Milford, MA, USA APPLICATION BENEFITS The Prep 150 LC System, an affordable, highly reliable system for preparative chromatography, is suitable
More informationHydrophilic Interaction Liquid Chromatography: Some Aspects of Solvent and Column Selectivity
Hydrophilic Interaction Liquid Chromatography: Some Aspects of Solvent and Column Selectivity Monica Dolci, Thermo Fisher Scientific, Runcorn, Cheshire, UK Technical Note 20544 Key Words Hydrophilic, HILIC,
More informationHypersil BDS Columns TG 01-05
TG 0-0 Hypersil BDS Columns Introduction Hypersil BDS columns have gained a reputation over the years as one of the most robust, reproducible and reliable HPLC column brands available. This Technical Guide
More informationLooking into the HPLC Column while Running CIP
Looking into the HPLC Column while Running CIP Imre SALLAY, PhD OSAKA SODA CO., LTD., Osaka, Japan imre@osaka-soda.co.jp The big application - By far the biggest RP silica application is insulin purification.
More information[ Care and Use Manual ]
Oasis HLB DISKS I. Introduction Oasis HLB is a Hydrophilic-Lipophilic-Balanced, water-wettable, reversed-phase sorbent for all your SPE needs. It is made from a specific ratio of two monomers, the hydrophilic
More information1.7µm Fortis UHPLC Columns
Strength in Technology.7µm Fortis Columns NEW Phase Chemistries - Fortis Ho (polar endcapped) - Fortis Amino - Fortis HILIC Diol Ultra High Pressure Chromatography 8 Chemistry Choices Increase Efficiency
More informationCellufine Butyl Cellufine Phenyl
Hydrophobic Interaction Chromatography Media Cellufine Butyl Cellufine Phenyl Technical Data Sheet 2-1, Otemachi 2-Chome Chiyoda-ku, Tokyo 100-8105 JAPAN Phone +81-3-3243-6150 Fax +81-3-3243-6219 e-mail:
More informationpenta-hilic UHPLC COLUMNS
penta-hilic UHPLC COLUMNS penta-hilic Highly retentive, proprietary penta-hydroxy-ligand Excellent peak shape for polar compounds with a variety of functional groups: acids, bases, zwitterions strong and
More informationP rocess chromatographic purification of pharmaceuticals. Silica-based packing materials for PREP HPLC, SFC and SMB. Dossier
Silica-based packing materials for PREP HPLC, SFC and SMB D. Sanchez Eka Chemicals AB, Separation Products, 44580 Bohus, Sweden Silica-based packings for preparative HPLC, SFC and SMB are today manufactured
More informationChromegaChiral TM CSP Media and Columns
ChromegaChiral TM CSP Media and Columns p h a r m a c e u t i c a l e n v i r o n m e n t a l c h e m i c a l b i o c h e m i c a l s e p a r a t i o n & p u r i f i c a t i o n ES Industries 701 S. Route
More informationTechnical Information
216 Miscellaneous Miscellaneous 217 Technical Information Contents Column Handling... 218-220 Mobile Phases for RP-Columns... 221 HPLC Column Performance... 222 Inspection Reports... 223 FAQ... 224-227
More informationSRT -10/10C (10 µm ) Fast Protein Purification For FPLC, HPLC and Prep LC. Sepax Technologies, Inc. Preparative Size Exclusion Chromatography
Sepax Technologies, Inc. Preparative Size Exclusion Chromatography SRT -0/0C (0 µm ) Fast Protein Purification For FPLC, HPLC and Prep LC Better Surface Chemistry for Better Separation SRT -0/0C Size Exclusion
More informationTwelve years of silica-based HPLC purification with focus on peptides an overview. Hans Liliedahl, Ph.D.
Twelve years of silica-based HPLC purification with focus on peptides an overview Hans Liliedahl, Ph.D. General Manager, Separation Products, Eka Chemicals Kromasil The way to peak performance in liquid
More informationcolumns Acclaim Mixed-Mode WCX-1 for Separating Basic Molecules
columns Acclaim Mixed-Mode WCX- for Separating Basic Molecules The Acclaim Mixed-Mode WCX- is a novel, high-efficiency, silica-based column specially designed for separating various basic analytes. This
More informationLiquid Chromatography
Liquid Chromatography 1. Introduction and Column Packing Material 2. Retention Mechanisms in Liquid Chromatography 3. Method Development 4. Column Preparation 5. General Instrumental aspects 6. Detectors
More informationComparison of different aqueous mobile phase HPLC techniques
June 009 ewsletter Pharmaceutical Analysis: What is Your Problem? SIELC Technologies, Inc., Prospect Heights, IL 0070 Pharmaceutical analysis involves liquid chromatography of various compounds, from active
More informationSPE. Simply Efficient! Watchers bond Solid Phase Extraction by ISU. Ver
SPE Simply Efficient! Watchers bond Solid Phase Extraction by ISU Ver. 05-11 Solid Phase Extraction Basic principles of Solid Phase Extraction Solid phase extraction (SPE) is a powerful method for sample
More informationIon Exchange Columns ---- Inertsil AX 078 Inertsil CX 080. HPLC Column Catalog
Ion Exchange ---- Inertsil AX 078 Inertsil CX 080 HPLC Column Catalog 077 Inertsil AX Physical Properties Silica : Series High Purity Silica Gel : μm Surface Area : 0 m /g Pore Size : 00 Å (0 nm) Pore
More information1.7 m Fortis UHPLC Columns
Strength in Technology 1.7 m Fortis Columns Ultra High Pressure Chromatography Improve your Performance 8 Chemistry Choices Increase Efficiency Increase Speed Improve Resolution Greater Sensitivity Lower
More informationHigh Performance Liquid Chromatography
High Performance Liquid Chromatography What is HPLC? It is a separation technique that involves: Injection of small volume of liquid sample Into a tube packed with a tiny particles (stationary phase).
More informationSepax SRT -C, Zenix -C SEC Phases
Sepax SRT -C, Zenix -C SEC Phases Complimentary Phases to SRT for Derivatized Monoclonal Antibodies General Description Stationary Phase Structure SRT, Zenix, SRT-C and Zenix-C SEC phases developed based
More informationChromegaChiral TM CSP Media and Columns
ChromegaChiral TM CSP Media and Columns p h a r m a c e u t i c a l e n v i r o n m e n t a l c h e m i c a l b i o c h e m i c a l s e p a r a t i o n & p u r i f i c a t i o n ES Industries 701 S. Route
More informationLC-MS/MS Method for the Determination of Diclofenac in Human Plasma
LC-MS/MS Method for the Determination of Diclofenac in Human Plasma J. Jones, Thermo Fisher Scientific, Runcorn, Cheshire, UK Application Note 20569 Key Words SPE, SOLA, Accucore RP-MS, diclofenac, Core
More informationANALYSIS OF BASIC COMPOUNDS
COMPARISON OF Fully AND Superficially POROUS PARTICLE COLUMNS FOR THE ANALYSIS OF BASIC COMPOUNDS Kenneth J. Fountain, Jane Xu, Zhe Yin, Pamela C. Iraneta, Diane M. Diehl Waters Corporation GOAL Compare
More informationEVOLUTE WCX Columns for Solid Phase Extraction of Quaternary Amines and Strongly Basic Compounds from Aqueous Samples
TN143 EVOLUTE WCX Columns for Solid Phase Extraction of Quaternary Amines and Strongly Basic Compounds from Aqueous Samples This Chemistry Data Sheet provides guidelines for the extraction of quaternary
More informationION CHROMATOGRAPHY SYSTEM S 150
ION CHROMATOGRAPHY SYSTEM S 150 WATER ANALYSIS ENVIRONMENTAL ANALYSIS ANION & CATION ANALYSIS ION CHROMATOGRAPHY IIon Chromatography is an analytical separation technique based on ionic interactions. Dissolved
More informationPure Chromatography Consumables Pure flexibility. Pure specialization. Pure convenience.
Pure Chromatography Consumables Pure flexibility. Pure specialization. Pure convenience. Pure Consumables More focus on your application The Pure consumable portfolio offers an unrivaled range of products
More informationUPLC Method Development and Validation
UPLC Method Development and Validation Rev. 2 2008 Waters Corporation Challenges of Method Development Methods are developed throughout the drug development process Samples vary in complexity Redundancy
More informationCation Exchange HPLC Columns
Cation Exchange HPLC Columns Hamilton offers seven polymeric packing materials for cation exchange separations. Type Recommended Application(s) PRP-X00 PRP-X00 PRP-X800 HC-0 HC-7 Ca + HC-7 H + HC-7 Pb
More informationKromasil. for your analytical HPLC. Kromasil. The way to peak performance in liquid chromatography
Kromasil for your analytical HPLC Kromasil The way to peak performance in liquid chromatography Kromasil is known, worldwide, for its high performance and excellent total economy in preparative and industrial
More informationThermo Scientific Syncronis HPLC Columns. Remarkable separations guaranteed time after time
Thermo Scientific Syncronis HPLC Columns Remarkable separations guaranteed time after time Syncronis HPLC and UHPLC Columns Remarkable separations guaranteed time after time When developing a new method,
More informationKromasil Eternity Designed for long life. For use in HPLC and UHPLC
Kromasil Eternity Designed for long life For use in HPLC and UHPLC The long-lasting phase for demanding applications Imagine working under virtually no ph restrictions during method development. That s
More informationHICHROM. Chromatography Columns and Supplies. SAMPLE PREPARATION Solid Phase Extraction - SOLA & HyperSep. Catalogue 9.
HICHROM Chromatography Columns and Supplies SAMPLE PREPARATION Solid Extraction - SOLA & HyperSep Catalogue 9 The Markham Centre, Station Road Theale, Reading, Berks, RG7 4PE, UK Tel: +44 (0)8 930 3660
More informationProPac WCX-10 Columns
ProPac WCX-10 Columns Guidance for column use Tips to maximize column lifetime ProPac WCX-10 Column Tips and Tricks This guide provides essential information and invaluable guidelines for mobile phases,
More informationHigh Performance Liquid Chromatography
STANDARDBASE techniques: High Performance Liquid Chromatography Drenthe College, The Netherlands 1. Introduction HPLC. High Performance Liquid Chromatography High Performance Liquid Chromatography (HPLC)
More informationKromasil Eternity Designed for long life
Kromasil Eternity Designed for long life For use in HPLC and UHPLC Kromasil The long-lasting phase for demanding applications Imagine working under virtually no ph restrictions during method development.
More informationStrategies for the Flash Purification of Highly Polar Compounds
trategies for the Flash Purification of Highly Polar Compounds Jack E. ilver, jsilver@teledyne.com, Paul Bellinghausen, and ancy Fowler, Teledyne Isco, Inc., 47 uperior treet, Lincoln, E 6854 Abstract
More informationSunniest C18 Sunniest RP-AQUA Sunniest C8 Patent pending
Patent pending Website : www.chromtech.net.au E-mail : info@chromtech.net.au telno : 0 97 0... in AUSTRALIA A Novel Bonding Technique (patent pending) An unique trifunctional silyl-reagent was developed
More informationHiTrap HIC Selection Kit
GE Healthcare Data File 18-1143-21 AC Hydrophobic interaction chromatography HiTrap HIC Selection Kit Introduction The HiTrap HIC Selection Kit consists of seven hydrophobic interaction chromatography
More informationINSTRUCTION MANUAL FOR CHIRALPAK ZWIX(+) and CHIRALPAK ZWIX(-)
800 orth Five Points Road West Chester, PA 19380 800 6 CIRAL Tel: 610-594-2100 Fax: 610-594-2325 chiral@chiraltech.com www.chiraltech.com ISTRUCTI MAUAL FR CIRALPAK ZWIX(+) and CIRALPAK ZWIX(-) Semi-Preparative
More informationChiral separations efficient, fast and productive
Chiral separations efficient, fast and productive By Per Jageland*, Mattias Bengtsson and Kristina Hallman AkzoNobel Eka Chemicals AB, Separation Products SE 445 80 Bohus Sweden Introduction Chromatographic
More informationHydrophilic Interaction Liquid Chromatography: Method Development Approaches
Hydrophilic Interaction Liquid Chromatography: Method Development Approaches Monica Dolci, Luisa Pereira, and Tony Edge Thermo Fisher Scientific, Runcorn, Cheshire, UK Abstract This poster summarizes the
More informationcolumns IonPac SCS 1 Silica Cation Separator
columns IonPac SCS Silica Cation Separator The SCS Silica Cation Separator is designed for use with nonsuppressed conductivity detection, or single-column ion chromatography (SCIC). This column is particularly
More informationPrep 150 LC System: Considerations for Analytical to Preparative Scaling
Andrew Aubin and Jo-Ann Jablonski Waters Corporation, Milford, MA, USA APPLICATION BENEFITS The Prep 150 LC System is an affordable, highly reliable system for preparative chromatography and is suitable
More informationLC Column Troubleshooting. Do you have an equivalent column for my LC column?
LC Column Troubleshooting Do you have an equivalent column for my LC column? LC columns from different suppliers may have very different retention properties even if the bonding is the same. Although there
More informationBiotage 2012 Webinar series
Biotage 2012 Webinar series Title: Isolera Spektra - A Revolution in Intelligent Flash Chromatography Date: 13 th June 2012 Summary: Automated flash has until today been based upon simple evolutionary
More informationSTUDY OF LOADABILITY AND SELECTIVITY OF PHARMACEUTICAL COMPOUNDS ON RPLC COLUMNS
STUDY OF LOADABILITY AND SELECTIVITY OF PHARMACEUTICAL COMPOUNDS ON RPLC COLUMNS Fang Xia, Jie Y. Cavanaugh, Uwe Neue, Jeffrey R. Mazzeo, Diane M. Diehl Waters Corporation, Milford, MA USA OVERVIEW- INTRODUCTION-
More informationACE Ultra Inert Base Deactivated HPLC Columns
ACE Ultra Inert Base Deactivated HPLC Columns Contents Page ACE HPLC Columns...- Independent Comparison of HPLC Columns #... Independent Comparison of HPLC Columns #... ACE 00Å HPLC Columns Specifications...-
More informationTechnical Information
356 Miscellaneous Miscellaneous 357 Technical Information Contents Column Handling... 358-360 Mobile Phases for Reversed Phase Columns... 361 HPLC Column Performance... 362 Inspection Reports... 363 FAQ...
More information