Automatic Potentiometric Titrator [AT-710S]
|
|
- Vivian Fields
- 6 years ago
- Views:
Transcription
1 Automatic Potentiometric Titrator [AT-710S] Large color TFT-LCD with a touch panel (8.4-inch) enables easy key entry. Monitoring temperature during titration ensures safe measurements. Features Titrant Information is stored in an IC chip in the burette unit (Smart burette) Information stored in the electrode cable (Smart electrode) New burette unit Large color TFT-LCD with a touch panel(8.4-inch) Two different user levels and permisions Two different potentials, such as ph/ transmittance, ph/ conductivity or ph/ temperature can be logged simultaneously. Monitoring temperature during titration ensures safe measurements Measurement results are converted to PDF and can be stored in a USB flash drive Applications Industrial products, Medical goods, Food, Petroleum products, etc.
2 Technical Specifications Product configuration MCU-710S + AT IDP-100 printer + propeller stirrer Detection range 1) Potentiometric: 2) ph: 3) Temperature mv mv ph C Titration modes Auto titration, auto intermit, intermit, Stat Methods Standard methods 120, combined methods 10 (max. 5 methods can be linked) Kinds of titrations Potentiometric (acid/base, redox, precipitation, chelometric) Photometric, Polarization, Conductometric Titration forms Full titration (Auto EP detection), EP Stop, Level Stop Special applications Measurement of electrode potential (ph, potential), acid dissociation constant (pk a) Simultaneous recording of 2 potentials (e.g. ph and %T) Learn titration Display 8.4 inch color LCD 800 x 600 dots touch screen Languages English, Japanese, Mandarin Chinese, Korean, Russian, Spanish, German, French
3 Calculations Concentration, statistics (mean, SD and RSD) Automatic averaging of blank and factor values Data storage On board memory: 500 results GLP functions Operators: Titrant: Performance checks: Maintenance of electrodes: Burette capacity: Up to 10 operators can be registered. User group administration. Reminder of date of factor measurement, alarm to indicate remaining reagent, reminder to replace piston, history of factor measurement. Reminder of scheduled check date, record of check results. Record of electrode calibration history, reminder for electrode calibrations, record of calibration history, electrode performance check, history of electrode performance Automatic burette performance test. Record of results of burette performance tests. Operating hours counter. Burette capacity 20 ml glass burette with brown cover 5 ml, 10mL, 1mL standard option GLP / GMP functions Definable periodic interval for system performance checks Automatic burette system performance check with periodic alert Results of the last 10 performance checks are stored System / user name can be defined Burette drive Resolution 20'000 steps Burette precision 50 ml burette/auto dispenser ±0.5 ml 20 ml ± 0.02 ml 10 ml ± ml Repeatability ± 0.01 ml Repeatability ± ml
4 5 ml± 0.01 ml 1mL± ml Repeatability ± ml Repeatability ± ml Preamplifiers 1) STD 2) PTA 1) 3) POT 1) 4) CMT 1) 5) TET 1) ph (mv) and mv, 2 inputs (standard) Additional input for photometric sensor Additional input for polarized electrode Additional input for conductivity cell 2 ways and mv, 3 inputs 1) on request, factory installed External I/O RS-232C, 3 channels ELE, 1port USB, 1 port SS-BUS, 1 port Temp. sensor for dot matrix printer, electronic balance, Capture Software (SOFT-CAP) for Smart electrode for USB flash drive, thermal printer, A4 printer keyboard, barcode reader, foot switch, USB hub for CHA-700 sample changer, automatic piston burette (APB) Pt100 for volume expansion correction accuracy: ± 0.5 C Expandability Automatic piston burette Sample changer Can control up to 10 burette drives (including two built-in burettes) CHA-600, CHA-700 Ambient conditions Temperature: Rel. humidity: 5 35 C < 85% (no condensation) Power supply DC 24 V 1.9 A (main unit) AC V ±10 % 50/60 Hz (comes with AC adapter) Power consumption Main unit approx. 30 W
5 Dimensions 141(W) x 296(D) x 367(H) mm (without tubing) Weight Titration unit: Pinter: approx. 4 kg approx. 0.4 kg CE conformity EMC: LVD: EN61326 conforming EN conforming RE Directive Applications Food and Beverage Amino acids in Sake ph value and titrable acidity CO 2 content Chloride (NaCl) Free and total sulfurous acid Volatile acids Citric acid Phosphoric acid Calcium Ascorbic acid Kjehldahl nitrogen Fluoride Total iodine Nitrite Ash alkalinity Free fatty acids Iodine value Saponification value Formol number Reducing sugars Oxalic acid Free fatty acids Peroxide value Peroxide value of oleic acid ASTM D558 E203 D POV of animal fat Saccharin Cyclamate Methoxy and ethoxy groups AOAC Chemicals Petrochemicals Acid number of biodiesel Acid number of resin Peroxide number of kerosene Total acid number (TAN) Base number Total base number (TBN) Chloride Bromine number Bromine index H 2 S Mercaptan Saponification number Hydoxyl number Hydoxyl value of polyether polyol Organic chlorine content Isocyanate
6 Monomer residues in PE Carboxyl group in PET Sodium Hydroxide Purity of acrylic acid Nitrogenous bases Sodium Polyacrylate Acid consumption of detergent Purity of Benzoic Acid Sulfadimethoxine in dye Chloride in dyestuff Amino group in dyestuff ASTM D94 D664 D974 D1159 D2420 D2710 D2896 D3227 D4739 D4929 D5776 D6470 E1899 GOST ISO JISK 0070 K2501 K4101 K8073 K8150 K JPI 5S DIN DIN ISO 3771 DIN EN UOP IP 177 Water Total hardness (Ca and Mg) Alkalinity Chloride EN ISO 9963 DIN EPA Electronics / Surface Treatment / Power Generation Cu in metal Ni in metal Boric acid in nickel Tetrafluoroboric acid in Ni Surfactants in plating Cadmium in plating Cyanide in plating Tin in plating Chloride in plating Hydroxide and carbonate in plating Cr(IV) and Cr(III) in chromium H 2 SO 4 in etching solution
7 Chromic acid in chrome bath Ferrous salt in etching solution Ferric salt in etching solution Nickel Sulfate in electrolytic colorant Amine in electrodeposition paint Acid number in insulating oils Boric acid concentration Total acid number in insulating oils ASTM D974 BS 148 JIS C2101 K8137 K8142 JPI-5S
OPTION. Karl Fischer Moisture Titrator [Volumetric titration] Karl Fischer Moisture Titrator [Coulometric titration]
CN073 OPTION Bent-type Sampler for Powder 12-04576 "C" Bent-type Sampler for Powders phi18.5 1/10 Taper Glass Sampler for Light Weight Powder Finger Shaped Sampler 12-04452 12-04184 12-04454 ADP Straight-type
More informationAutomatic Potentiometric Titrator
Automatic Potentiometric Titrator AT-610 Automatic Potentiometric Titrator Two Different Titrations can be Performed Simultaneously --- Allow for Space-saving. Also, a Karl Fischer Moisture Titrator can
More informationLa nueva línea de tituladores y buretas
TITRONIC y TitroLine La nueva línea de tituladores y buretas TITRONIC and TitroLine The new titrators and burettes New from SI Analytics: Simplicity without sacrificing accuracy or features Introducing
More informationThe first address for Titration. TITRONIC 300 and TitroLine 5000
The first address for Titration TITRONIC 300 and TitroLine 5000 Selection table titration piston burettes TITRONIC and automatic titrators TitroLine The most important features of titrators TitroLine and
More informationAutomatic titrators, TitroMatic
112 TitroMatic These are the fourth generation of CRISON titrators. CRISON has over 25 years experience in this field and knows that, for certain applications, the performance and cost of large titrator
More informationMULTI_T. Digital Titrator for Multi-tasking Titrations
MULTI_T Digital Titrator for Multi-tasking Titrations Entering the Realm of Multi_T You are about to embark on a journey through the most powerful titration system on the market, Multi_T. But what is Multi_T?
More informationSemi-automatic titrators PH-Burette. A great ph-meter with integrated burette. Incredible price! Infinite possibilities
Semi-automatic titrators PH-Burette. A great ph-meter with integrated burette. Incredible price! Infinite possibilities instruments 5 YEARS G U A R A N T E E Quality at a reasonable price The optimum combination
More informationThermo Scientific Orion Star T900 Series Laboratory Titrators. Potentiometric titrators for performing automated ph, redox, or ion titrations
Thermo Scientific Orion Star T900 Series Laboratory Titrators Potentiometric titrators for performing automated ph, redox, or ion titrations Thermo Scientific Orion Star T900 Series Titrators Automate
More informationCompact Titration Compact Titrator G20. One Click Titration Simple & Dependable
Compact Titration Compact Titrator G20 One Click Titration Simple & Dependable Simplicity The Intelligent Helper for Simple Titrations One Click Titration Intuitive method adaptation Accurate results simply
More informationUDK. Distillation Units Series. A Full Range of Solutions for Kjeldahl Distillation LABSOLUTIONS
LABSOLUTIONS UDK Distillation Units Series A Full Range of Solutions for Kjeldahl Distillation ABCD The distillation unit is used to perform nitrogen and protein content analysis according to the Kjeldahl
More informationKjeltec 2300 Analyzer Unit
Kjeltec 2300 Analyzer Unit Automatic distillation and approved colorimetric titration for analysis of Kjeldahl nitrogen/protein, ammonium- nitrogen, TKN, Direct distillation (DD), volatile acids/ bases
More informationSingle Method On-line Analyzers
Single Method On-line Analyzers ADI 2016 Titrolyzer ADI 2018 Ion-Analyzer ADI 2019 Process Colorimeter ADI 2016 / 2018 / 2019 Automatic and dependable On-line Ion Analysis The single method Process Analyzers
More informationCompact Titration. Compact Titrator G20. One Click Titration Simple & Dependable
Compact Titration Compact Titrator G20 One Click Titration Simple & Dependable Simplicity The Intelligent Helper for Simple Titrations One Click Titration Intuitive method adaptation Accurate results simply
More informationSingle Method On-line Analyzers. ADI 2016 Titrolyzer ADI 2018 Ion-Analyzer ADI 2019 Process Colorimeter
Single Method On-line Analyzers ADI 2016 Titrolyzer ADI 2018 Ion-Analyzer ADI 2019 Process Colorimeter Automatic and dependable on-line ion analysis 02 The single method process analyzers from Metrohm
More informationADI 201Y Single Method On-line Analyzers
Applikon Analytical / ADI201Y Single Method On-line Analyzers ADI 201Y Single Method On-line Analyzers ADI 2016 Titrolyzer ADI 2018 Ion-Analyzer ADI 2019 Process Colorimeter ADI 2016 / 2018 / 2019 Automatic
More information2035 Process Analyzer. Customized online monitoring of industrial processes and wastewater
2035 Process Analyzer Customized online monitoring of industrial processes and wastewater The 2035 Process Analyzer at a glance 02 The 2035 Process Analyzer is the latest of Metrohm Process Analytics solutions
More informationKEM SET. for Beverage. Gas volume Internal gas pressure Air content Oxygen concentration Inside pressure Density Brix
Acidity Alkalinity for Beverage Gas volume Internal gas pressure Air content Oxygen concentration Inside pressure Density Brix Vitamin C Ca & Mg Acidity Vitamin C for Ca & Mg Ca Mg Alkalinity A Automatic
More informationKarl-Fischer Titration the method for determining water
Karl-Fischer Titration the method for determining water Quite some experienced analyst will be unpleasantly reminded by the pyridine smell, when hearing the name Karl Fischer. However, modern reagents
More informationApplication Note No. 116 / 2013 Nitrogen determination in sodium nitrate
Application Note No. 116 / 2013 Nitrogen determination in sodium nitrate KjelMaster K-375: Determination of nitrogen in sodium nitrate according the the Devarda method 1. Introduction An easy, quick and
More informationHigh Perfomance: AT-510 Low Cost : AT-500N-1, AT-500N-2 Multi-channel Software : AT-Win. FDA 21 CFR Part 11 Compliant Software : AT-Win/ER
High Perfomance: AT-510 Low Cost : AT-500N-1, AT-500N-2 Multi-channel Software : AT-Win CE marked for product safety ISO 9001 for quality assurance GLP/GMP conformed ISO 14001 environmental management
More informationDetermination of Total Base Number (TBN)
Application Note Determination of Total Base Number (TBN) ACCORDING TO ASTM D2896/ISO 3771 Introduction Determination of basic constituents in petroleum products by potentiometric titration with perchloric
More informationMobile coulometer for water determination anywhere you want
899 Coulometer Mobile coulometer for water determination anywhere you want Extremely small & compact Maximum flexibility due to independent power supply Automatic start of titration 899 Coulometer the
More informationJAPAN QUALITY. Automated Clinical Analyzer
JAPAN QUALITY Automated Clinical Analyzer Higher test performance and operability with new functions The clinical analyzer in the next stage 1 The best to the requirements for functionality and usability
More informationConcise laboratory catalogue
2008 Concise laboratory catalogue Portable and bench-top instruments for ph, EC, ISE, DO and C measurements. Simple and advanced models covering from routine measurements to maximum requirements in investigation.
More informationDM70 Hand-Held Dewpoint Meter for Spot-Checking Applications
DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications The Vaisala DRYCAP Hand-Held Dewpoint Meter DM70 offers accurate and fast measurement for industrial dewpoint applications, such as compressed
More informationJAPAN QUALITY. Automated Clinical Analyzer
JAPAN QUALITY Automated Clinical Analyzer Higher test performance and operability with new functions The clinical analyzer in the next stage 1 The best to the requirements for functionality and usability
More informationEasier Titration at any level of complexity: TitroLine alpha plus
Easier Titration at any level of complexity: TitroLine alpha plus Innovative electrochemistry from the very beginning By developing the glass electrode more than 70 years ago, we laid the foundation for
More informationAutomatic determination of the bromine number and the bromine index in petroleum products
Application Bulletin 177/5 e Automatic determination of the bromine number and the bromine Branch General analytical chemistry; organic chemistry; petrochemistry, biofuels; trace analysis; paints, lacquers,
More informationPascal ET is an handheld multifunction calibrator for the measurement and simulation of the following parameters: - pressure
DATASHEET Pascal ET Pascal ET is an handheld multifunction calibrator for the measurement and simulation of the following parameters: - pressure - electrical signals (ma, mv, V, ) - temperature (TC and
More informationSpeed and flexibility
Speed and flexibility Automate your environmental, water, detergent, food and beverage analysis Thermo Scientific Gallery and Gallery Plus discrete industrial analyzers Improve productivity, reproducible
More informationThe Clinical Chemistry System that offers more so you do less!
The Clinical Chemistry System that offers more so you do less! A unique level of automation in a compact system Safe and flexible sample management Fully automatic cuvette management Cuvette management
More informationMercaptan Sulfur in Gasoline and Kerosene Aviation Turbine and Distillate Fuels
Application Note Mercaptan Sulfur in Gasoline and Kerosene Aviation Turbine and Distillate Fuels USING ASTM D 3227 Introduction For the determination of mercaptan sulfur in a range from 3 mg/kg 100 mg/kg.
More informationPhotometer AL250. Scroll Memory (SM) N.I.S.T Traceability. Highlights
Photometer AL250 10 The AL250 models each offer one test method, while the AL250+ units are programmed for a number of different parameters. The units supply accurate, reproducible results very quickly.
More informationTitrex ACT titrators have been designed to simply and precisely satisfy and perform the widest range of potentiometric titrations: acid-base, redox,
Titrex ACT titrators have been designed to simply and precisely satisfy and perform the widest range of potentiometric titrations: acid-base, redox, argentometric, complexometric titrations Compact and
More informationApplication Note No. 117 / 2013 Ammonia determination in hair dye
Application Note No. 117 / 2013 Ammonia determination in hair dye KjelMaster K-375 with KjelSampler K-376: Ammonia determination in hair dye with direct distillation 1. Introduction An easy and reliable
More informationTitration TITRATORS, SAMPLE CHANGERS, SOFTWARE AND ELECTRODES
Titration TITRATORS, SAMPLE CHANGERS, SOFTWARE AND ELECTRODES Content 1. Overview Page 4 1.1 Selection table Page 10 2. Applications overview Page 12 3. Burettes and Titrators 3.1 TITRONIC 300 Page 14
More informationTitration TITRATORS, SAMPLE CHANGERS, SOFTWARE AND ELECTRODES
Titration TITRATORS, SAMPLE CHANGERS, SOFTWARE AND ELECTRODES Content 1. Overview Page 4 1.1 Selection table Page 10 2. Applications overview Page 12 3. Burettes and Titrators 3.1 TITRONIC 300 Page 14
More informationTitration TITRATORS, SAMPLE CHANGERS, SOFTWARE AND ELECTRODES
Titration TITRATORS, SAMPLE CHANGERS, SOFTWARE AND ELECTRODES Content 1. Overview Page 4 1.1 Selection table Page 10 2. Applications overview Page 12 3. Burettes and Titrators 3.1 TITRONIC 300 Page 14
More informationCHEMISTRY WORKSTATION. The power of proven quality GIVING YOU PEACE OF MIND
CHEMISTRY WORKSTATION The power of proven quality GIVING YOU PEACE OF MIND The new Vitalab Flexor XL extends the excellent reputation of the Flexor family. With over five thousand Flexor installations
More informationA new chapter. medicacorp.com
A new chapter. \EDIC@ medicacorp.com Same operational reliability. Reliable performance, test after test. The photometer s xenon fl ash lamp typically has a 5-year use life and is maintenance-free. No
More informationFrom 1 ppm to 100% Karl Fischer water content determination
METTLER TOLEDO Karl Fischer Titrators DL39 & DL32 Coulometers DL38 & DL31 Volumeters Oven sample changer Stromboli From 1 ppm to 100% Karl Fischer water content determination Karl Fischer water content
More informationMERCAPTAN SULFUR IN GASOLINE & KEROSENE AVIATION TURBINE & DISTILLATE FUELS USING ASTM D3227
MERCAPTAN SULFUR IN GASOLINE & KEROSENE AVIATION TURBINE & DISTILLATE FUELS USING ASTM D3227 Titration Application Use For the determination of mercaptan sulfur in a range from 3 mg/kg 100 mg/kg. Required
More informationEasy and reliable KF titrations From 1 ppm to 100%
AGC Karl Book Fischer 20% Titrators Cyan Volumetric KF Titrators DL31, DL38 Coulometric KF Titrators DL32, DL39 Oven sample changer Stromboli Easy and reliable KF titrations From 1 ppm to 100% Karl Fischer
More informationKEM SET. for FOOD. Salinity. Brix Density Concentration. Acid Value POV. Water Content
Salinity for FOOD Brix Density Concentration Acid Value POV Water Content Vitamin C Acid Value / POV Salinity Vitamin C for FOOD A Automatic Potentiometric Titrator B Automatic Potentiometric Titrator
More informationAutomated Clinical Analyzer
Automated Clinical Analyzer Improved ease of operation and better test efficiency, and provides the optimal solution for routine operations, STAT operation and a broad range of clinical analysis requirements.
More informationPURCHASE DIVISION DEPARTMENT QUALITY MANUAL. CPRI Section II -Technical Specification
Revision No. : 02 Dt of Revision : 17.9.2012 Issued by : Q A Section : 0 Topic : FORMAT 6 OF PROCUREMENT PROCEDURE OF CPRI (NON-WORKS) Tender Enquery No : PUR/DMD-33/16-17 Name of the Equipment: Auto Titrator
More informationElectrochemistry LEC Potentiometric ph titration (phosphoric acid in a soft drink) What you need: What you can learn about
Electrochemistry LEC 06 What you can learn about Galvanic cell Types of electrodes Nernst equation Potentiometry Principle and tasks The cell voltage and the Galvani voltage of the electrodes of an galvanic
More informationCOMBI has been developed to be easily integrated in all types of laboratories and hospitals for routine, emergency as well as specific analysis.
L A B O R A T O R Y Clinical chemistry analyzers and reagents for laboratories needs. BIOCHEMICAL SYSTEMS INTERNATIONAL, as a diagnostic device manufacturer, has been researching for 25 years, with the
More information473 Dew Point Hygrometer
High Performance Chilled Mirror Hygrometer With Cable Mounted Measuring Heads Highly precise chilled mirror dew point technology Cable mounted dew point and temperature measurement Aspirated and direct
More information1. Introduction. 2. Equipment. 3. Chemicals and Materials
1. Introduction Nitrogen and protein determination in food and feed are described in numerous standard procedures [1-3]. Therein, the titration specifications vary between boric acid and back titration.
More informationTITRATION CATALOG. The new titrators and burettes
TITRATION CATALOG The new titrators and burettes Content Selection table titration Page 4 TITRONIC and TitroLine new series Page 6 TITRONIC 500 Page 10 TitroLine 6000 Page 12 TitroLine 7000 Page 14 Applications
More informationDM70. Hand-held Dewpoint Meter. Truly Fast Response - Superior Long-term Stability
DM70 Hand-held Dewpoint Meter Truly Fast Response - Superior Long-term Stability DM70 - When Dry Air Is Important The Vaisala DM70 Hand-held Dewpoint Meter offers stable and fast measurement for industrial
More informationUSER MANUAL. Aquamax TAN
Aquamax TAN USER MANUAL GUARANTEE The Aquamax TAN titrators are guaranteed against any manufacturing defect or component failure. GRScientific will repair or replace, free of charge, any defective component
More informationApplication Note No. 310/2018
Application Note No. 310/2018 Nitrogen determination in compound fertilizer according to Devarda KjelFlex K-360 with Devarda Splash Protector, Metrohm Titrino 877 www.buchi.com Quality in your hands 1.
More informationRA-520N/RA-500N/RA-410
Refractometer/Brix Meter RA-520N/RA-500N/RA-410 High-performance built-in thermostatic feature Compatible with PC card (RA-520N only) Interface to Barcode reader for easier input of sample ID CE marked
More information473 Dew Point Hygrometer
gh Performance Chilled Hygrometer With Cable Mounted Measuring Heads ghly precise chilled mirror dew point technology Cable mounted dew point and temperature measurement Aspirated and direct insertion
More informationINE-PHS-3E ph Meter Operating Manual
INE-PHS-3E ph Meter Operating Manual PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION Hagavish st. Israel 58817 Tel: 972 3 5595252, Fax: 972 3 5594529 mrc@mrclab.com MRC.12.16 ADVICE: Read this instruction
More informationApplication Note. An Optimum Solution for the Automatic Control of Cutting Oils
An Optimum Solution for the Automatic Control of Cutting Oils Cutting oils are widely used in many mechanical machining processes such as cutting and grinding. The chemical and physical parameters of the
More informationStandard specifications ZX165UFE02001
Standard specifications ZXUF000 May, 0 KAWASAKI HAVY INDUSTRIS, LTD. ROBOT DIVISION Materials and specifications are subject to change without notice. Specification : (Arm): (Controller): 00-DA 0-00DA
More informationApplication Bulletin
Of interest to: General analytical laboratories A 1, 2, 4, 7, 10, 11, 12, 13 Chloride titrations with potentiometric indication Summary Besides acid/base titrations, the titrimetric determination of chloride
More informationThe Ordering Code for various standard model Recorders with an AC supply and without any additional options are as follows:
The basic PC software is supplied free with the recorder. There is an additional charge for the extensive Data Acquisition Software supplied with communication of RS-232/422/485 or Ethernet. The Ordering
More informationIon Selective Electrodes
Ion Selective Electrodes A n a l y t i c a l S e n s o r s & I n s t r u m e n t s I O N S E L E C T I V E E L E C T R O D Ion Selective Electrodes (ISE) are membrane electrodes that respond selectively
More informationTitration Catalog. Systems and Autosampler
Titration Catalog Systems and Autosampler Hanna Instruments Titration Systems Titration is used in analytical chemistry to determine the amount or concentration of a substance, known as the analyte. Titration
More informationION SELECTIVE MEASUREMENT
Electrodes Solutions Instrumentation ION SELECTIVE MEASUREMENT catalog featuring our full line of Ion Selective Electrodes Introduction Hanna Instruments Ion Selective Measurement Catalog Authorized Distributor
More informationProcess Instrumentation analyzers
PCA300 Family Chlorine, ph, ORP and Temperature Analyzers Backlit LCD display Nema 4X protection.10 DPD chlorine measurement method Colorimeter diagnostics Reagent reminder Amplified ph/temperature probe
More informationReagents for Chemical Test Kits
for Chemical Test Kits Acidity, methyl orange method ; 0 to 500 mg/l HI 3820-100 Reagent kit for 110 tests (CaCO 3 ) Acidity, olive oil, titration with hydroxide 0.00 to 1.00% HI 3897 Reagent kit for 6
More informationApplication Bulletin
No. 292e Application Bulletin Of interest to: Plating industry, semiconductor industry, automotive industry, aeronautic industry, electroless nickel plating, hypophosphite, alkalinity P 9, 10 Determination
More informationIon-selective Measurements
Ion-selective Measurements Ion-selective measurement is a method for determining the concentration of dissolved ions. Potassium ions, sodium ions, fluoride or chloride are examples of such cations and
More informationED 701 General Industry Pressure Transmitter
ED 701 General Industry Pressure Transmitter Standard industrial process connections Complete range of electrical connections 4... 20 ma and Voltage outputs Accuracy: 0.1%, 0.2% and 0.4% FS Quick response
More informationIon-Selective Measurements
Ion-Selective Measurements Ion-selective measurement is a method for determining the concentration of dissolved ions. Potassium ions, sodium ions, fluoride or chloride are examples of such cations and
More informationProximity Sensor Ideal for High Temperatures and Cleaning Processes. Applicable to 120 C
ASH & ALAIN INDIA PVT LTD S-00, F.I.E.E., Okhla Industrial Area, Phase-ii, New Delhi-000(India) Tel : 0-797575 Fax : 0-79757 E-mail : sales@ashalain.com Proximity Ideal for High Temperatures and Cleaning
More informationChemistry 301 Test #1
Name: KEY Pledge: I have neither given nor received aid on this test Chemistry 301 Test #1 Point Total: 100 pts possible 8 pts 1. In 2-4 sentences, explain the fundamental basis of quantitative analysis
More informationPTG-NIR Powder Characterisation System (not yet released for selling to end users)
Powder Characterisation System - PTG-NIR PTG-NIR Powder Characterisation System (not yet released for selling to end users) The PTG-NIR automatic powder and granule inspection system with integrated NIR
More informationFertilizer Methods List for Automated Ion Analyzers. Flow Injection Analysis
Fertilizer Methods List for Automated Ion Analyzers Flow Injection Analysis December, 2014 QuikChem Fertilizer Methods List Use this list to: Identify and select analytical methods for your analyte, range,
More informationAutomatic Potentiometric Titrator AT-710 Operation Manual
Automatic Potentiometric Titrator AT-710 Operation Manual Please read this manual thoroughly in advance for the best performance of the equipment. AN 59-00419-01Ver.00 Introduction Overview of the instrument
More information473-SHX Dew Point Mirror
Humidity and Temperature Reference Hygrometer For Temperature up to 125 C Precise and stable chilled mirror dew point mirror technology High temperature optical components High temperature sample fan Cable
More informationNanotechnology Sensors
ESILAB PACK : 1 Ion + ph Nanotechnology Sensors email : contact@water-kits.fr This revolutionary technology based on carbon nanotubes hugely simplifies the potentiometric measurements. Measurement & calibration
More informationSPECIFICATION SHEET AUTOMATIC TITRATOR. Model: AUT Automatic Titrator - Issue: AUT R1 Page 1 ISO ISO-9001
ISO-14001 ISO-9001 SPECIFICATION SHEET AUTOMATIC TITRATOR : AUT-501 The AUT-501 is a high performance, microprocessor-based, solutiontype system which can perform all types of classical routines. The instrument
More informationSpeedDigester K-436, K-439 / KjelFlex K-360 Nitrogen Determination in Nitrate-Free Fertilizer according to the micro-kjeldahl Method 074/2011
SpeedDigester K-436, K-439 / KjelFlex K-360 Nitrogen Determination in Nitrate-Free Fertilizer according to the micro-kjeldahl Method 074/2011 074/2011 SpeedDigester K-436 / K-439 KjelFlex K-360 SHORT NOTE
More informationDewpoint Meter Data Sheet / Instructions
Paint Test Equipment Dewpoint Meter Data Sheet / Instructions Dewpoint Meter Information ISO 8502-4: Preparation of steel substrates before application of paints and related products. Tests for the assessment
More informationTitroLine alpha plus From precise programmable piston burette to fully automatic titration system
LABWARE SCHOTT-GERÄTE TITRATORS AND PISTON BURETTES E EQ EP ppm H 2 O ml EQ TitroLine alpha plus From precise programmable piston burette to fully automatic titration system EP ppm H 2 O ml EQ EP ppm H
More informationISEmax CAM40/CAS40. Technical Information
Technical Information Online measurement of nutrient parameters Ion-selective electrode system for the continuous measurement of ammonium and nitrate Application The ion-selective electrode system works
More informationUDK. Distillation Units Series. A Full Range of Solutions for Kjeldahl Distillation LABSOLUTIONS
LABSOLUTIONS UDK Distillation Units Series A Full Range of Solutions for Kjeldahl Distillation ABCD The distillation unit is used to perform nitrogen and protein content analysis according to the Kjeldahl
More informationData Sheet / Instructions. Dewpoint MeterO
Data Sheet / Instructions Dewpoint MeterO Dewpoint Meter ISO 8502-4: Preparation of steel substrates before application of paints and related products. Tests for the assessment of surface cleanliness.
More informationMetso Concentration Measurement 3300
Metso Concentration Measurement 3300 Metso Concentration 3300 Accurate direct in-line measurement The Concentration Measurement is provided with intelligent technology calculating the concentration of
More informationApplication Note No. 230/2016
Application Note No. 230/2016 Nitrogen determination in bovine serum albumin KjelDigester K-436, KjelFlex K-360: Comparison of standard-kjeldahl and micro-kjeldahl for nitrogen determination in pharmaceutical
More informationChlorine, Total. USEPA DPD Method 1 Method to mg/l as Cl 2 Chemkey Reagents. Test preparation. Before starting.
Chlorine, Total DOC316.53.01497 USEPA DPD Method 1 Method 10260 0.04 to 10.00 mg/l as Cl 2 Chemkey Reagents Scope and application: For drinking water. This product has not been evaluated to test for chlorine
More informationISOCON-6. 24V AC or DC POWERED ISOLATING SIGNAL CONVERTER
ISOCON-6 24V AC or DC POWERED ISOLATING SIGNAL CONVERTER Whilst every effort has been taken to ensure the accuracy of this document, we accept no responsibility for damage, injury, loss or expense resulting
More informationCLINICAL CHEMISTRY ANALYSER. The economical solution for all your needs GIVING YOU PEACE OF MIND
CLINICAL CHEMISTRY ANALYSER The economical solution for all your needs GIVING YOU PEACE OF MIND Proven and modern technology meeting all your needs: reliability, flexibility, convenience and economy. The
More informationCS Series. Capacitance Type. Type. Proximity Sensor. Features
INFORMATI Series Features Capacitance Type - Metal cylinder/resin cylinder/square type - Non-metal objects such as wood, paper, plastic and water can be detected. - The operating distance is adjustable
More informationElectrodes - Connect/Replace. Reagents - Install/Replace. Select method ph electrode calibration. Reagent calibration.
Short-For t-form Reminders Electrodes - Connect/Replace Reagents - Install/Replace Select method ph electrode calibration Reagent calibration Running methods Running sequences Direct measurements Maintenance
More informationWATER ANALYSIS The ph Value. The Redox Potential. ALMEMO ph and Redox Measurement. The Electrical Conductivity
www.ahlborn.com WATER ANALYSIS The ph Value The ph value is a logarithmic measure for the concentration of the H ions in a hydrous solution and indicates, by a numerical value, whether the solution has
More informationApplication Note No. 197/2015 Nitrogen and protein determination in dairy products Nitrogen determination in sodium nitrate
Application Note No. 197/2015 Nitrogen and protein determination in dairy products Nitrogen determination in sodium nitrate KjelDigester K-449, KjelMaster K-375 with KjelSampler K-376: Accelerated Nitrogen
More informationOne-hand ph/temperature measuring instrument
One-hand ph/temperature measuring instrument testo 205 ph tip embedded in breakage-proof plastic ph Combined penetration tip with temperature probe Maintenance-free gel electrolyte C Measurement tip exchangeable
More informationApplication Note #97 Alkalinity and Hardness by Potentiometric Titration Using TRIS Buffer
Application Note #97 Alkalinity and Hardness by Potentiometric Titration Using TRIS Buffer Updated July 2017 Introduction: Alkalinity refers to the acid-neutralizing or buffering capacity of a solution.
More informationADI 2040 Process Analyzer
ADI 2040 Process Analyzer Multi-purpose wet chemical analysis Multi-purpose Wet Chemical Analysis ADI 2040 The Metrohm Applikon ADI 2040 Process Analyzer is a multipurpose wet chemical analyzer, that has
More informationDrug Testing Solutions INDIKO DRUG TESTING ANALYZER. 1 P F
Drug Testing Solutions INDIKO DRUG TESTING ANALYZER 1 www.dtpm.ws P. 256-845-1261 F. 888-317-4178 sales@dtpm.ws Overview Indiko Sample oriented random access system for clinical and specialty testing,
More informationTiter determination in potentiometry
Branch General analytical chemistry Keywords Titration; potentiometric titration; titer; branch 1 Summary This Bulletin provides an overview of the potentiometric titer determination in common volumetric
More informationINFRARED THERMOMETER Model : TM-959
LED target light, Emissivity adjustment INFRARED THERMOMETER Model : TM-959 Your purchase of this I N F R A R E D THERMOMETER marks a step forward for you into the field of precision measurement. Although
More informationRapid RH Portable ph Meter. User's Manual
Rapid RH Portable ph Meter User's Manual This page intentionally left blank. 2 Contents 1. Introduction... 4 2. Included with the Rapid RH Portable ph Meter... 4 3. Understanding ph... 5 4. Calibrating
More information