Titrex ACT titrators have been designed to simply and precisely satisfy and perform the widest range of potentiometric titrations: acid-base, redox,

Size: px
Start display at page:

Download "Titrex ACT titrators have been designed to simply and precisely satisfy and perform the widest range of potentiometric titrations: acid-base, redox,"

Transcription

1 Titrex ACT titrators have been designed to simply and precisely satisfy and perform the widest range of potentiometric titrations: acid-base, redox, argentometric, complexometric titrations Compact and modular: Titrex ACT is a compact as well as modular instrument. It can be configured at will, therefore it is fitted to satisfy the ever-changing laboratory requirements. The burettes for titrant solutions and the peristaltic pumps for the auxiliary reactants can be integrated to the system at any time Upgrade: the software upgrade is simply performed by connecting the Titrex ACT to a PC Easy to use: the wide graphic display contains all the messages and the icons that make Titrex ACT extremely easy to use. The titrator guides the user in each programming phase, analysis and data interpretation On-line graphics: during the titration process the graphic trend is displayed in real time, so that the operator is immediately informed about the analysis trend GLP: each analytical report obtained with the Titrex is complete and reports: company/institution and operator name, analysis date and time, sample alphanumeric code, titrant consumption, volume/weight, result reported in the desired unit (e.g. %, g/l...) etc.

2 Titrex ACT Standard titration programs: (it is possible to save in memory up to 30 programs): FINAL POINT: titrations with pre-defined ph/mv value EQUIVALENCE: titrations with automatic localization of the equivalent point/s, and pre-defined or incremental additions during the titration (up to 4 equivalent points) Service programs: DOSAGE: dispensing of pre-defined fixed volumes PRIMING AND CLEANING: reactants loading and cleaning at the end of the work Calibration, measurements in ph/mv Programs specific to oenology: PH AND TOTAL ACIDITY: it is performed with a ph electrode (final point titration to ph 7.00) without sample pre-treatment FREE AND TOTAL SO2: it is performed with double platinum electrode, without sample pre-treatment. Once the sample aliquots have been proportioned in the respective titration vessels, the analysis includes the automatic additions of the auxiliary reactants (H2SO4 and NaOH) by means of peristaltic pumps, with automatic control of the waiting time (alkaline reaction for total SO2). Free, total and combined SO2 analysis can be performed on the same sample (double Ripper) as well REDUCING SUGARS: the analysis is performed by means of redox titration with a platinum electrode on decolorized and diluted within 25g/l sample. Once the sample aliquots (5ml) have been manually proportioned in the respective titration vessels the analysis can be performed by previous oxidation of the samples on heating plate. With the help of the heated sampler the analysis of the reduction sugars, including the oxidation, is fully automatic, with no intervention of the operator oenological division Hardware technical features: - wide, clear and evident graphic display - 2 outputs for combined electrodes: ph: (0.01pH) mv: ñ (0.1mV) - 1 output for reference electrode - 1 output for temperature sensor: C - parallel connection to printer and RS232 C serial connections to external PC and scale, RS 485 serial connection to burettes, optional peristaltic pumps (max. 5), 16-position standard or thermostatable sampling plate - plastic compact structure, dimensions (WxLxH) mm 610 x 310 x 360 (electrodes stand excluded) Precision burettes for titrant delivery (max. 4) equipped with: - extremely high resolution stepper motor (48,000 steps) - 10ml standard syringe made of graduated clear glass with interchangeable PtFE-tip - four-way valve for titrant inlet, washing reactant inlet, titrant delivery and connection to the syringe. The valve is completely made of anti-acid material The basic version includes: - general control central unit - n 1 automatic burette complete of delivery and exhaust pipe - instruction manual Control panel F a b c F10 F9 F8 F7 4 g h i 7 p q r s 3 d e f 5 j k l 6 m n o 8 t u v w x y z CE ENT F1 F2 F3 F4 F5 F6 Automatic Compact Titrator

3 Peripheral units: AUTOMATIC BURETTE FOR DOSING THE TITRANT REACTANTS (max. 4) Burette equipped with 48,000 stepper motor - four-way valve (titrant/cleaning reactant suction, titrant delivery, syringe) - 10ml clear glass syringe - 3 threaded fittings for delivery/suction/cleaning pipes PERISTALTIC PUMP FOR AUXILIARY REACTANTS DOSING (max. 5) Equipped with: - n 1 peristaltic pump complete of neoprene inner pipe and connections to suction/delivery pipes SINGLE ANALYSIS STAND Single analysis stand adjustable in height - drilled electrodes holding head for housing up to 5 delivery pipes (pumps and burettes), 3 sensors (electrodes and Pt100), 1 mechanical stirrer - round base supporting the titration vessel - threaded connector for burette delivery pipe connection and NS 14/23 plastic adapter for electrode fixing STIRRER Magnetic drive mechanical stirrer complete of 70cm long stirring glass blade PRINTER Pin printer LX300 + EPSON, 80 columns Equipped with: - 220V power supply cable - printer tape STANDARD AUTOSAMPLER 16-position autosampler (15 working positions and 1 fixed washing position) - drilled electrodes holding head for housing up to 8 delivery pipes (pumps and burettes), 3 sensors (electrodes and Pt100), 1 mechanical stirrer and complete of 8 burettes/pumps delivery pipes guides - extension cable for central unit connection to the mechanical stirrer - 2.3m long PtFE delivery pipe for burette complete of antidiffuser and autosampler head fixing fitting (connection to burette n 1) THERMOSTATABLE AUTOSAMPLER 16-position autosampler (15 working positions and 1 fixed washing position) complete of aluminium basin. Heating by thermoresistance and cooling by recycling cold water from external delivery. - drilled electrodes holding head for housing up to 8 delivery pipes (pumps and burettes), 3 sensors (electrodes and Pt100), 1 mechanical stirrer and complete of 8 burettes/pumps delivery pipes guides - extension cable for central unit connection to the mechanical stirrer - 2.3m long PtFE delivery pipe for burette, complete of antidiffuser and autosampler head fixing fitting (connection to burette n 1) - inlet and outlet for water recycle, thermoresistance temperature from +5 over environment temperature to +100 C - inch faucet metal fitting and 8 RICTAN pipe fitting 2.5 meters RITSAN - pipe, diam. 12 x 10 for drain power supply cable (220V)

4 Titrex ACT Versions: ph/total ACIDITYΔ with AS22 autosampler (auto-level sampling system): n 01 Act 1 burette 1 pump SQTV n 01 Burette titrant delivery pipe SQFT n 01 Titrant suction pipe SQFT n 01 Pump delivery/auto-level pipe SQFT n 01 BNC/S7 cable for ph electr., L = 3m SQFT n 01 Flushtrode PH Electrode HIFM FREE/TOTAL/COMBINED S02Δ with AS22 autosampler (auto-level sampling system): n 01 Act 1 burette 3 pumps SQTV n 01 Burette titrant delivery pipe SQFT n 01 Titrant suction pipe SQFT n 03 Pump delivery/auto-level pipe SQFT ph/ TOTAL ACIDITY/ FREE,TOTAL AND COMBINED S02Δ with AS22 autosampler (auto-level sampling system): n 01 Act 2 burettes 3 pumps SQTV n 02 Burette titrant delivery pipe SQFT n 02 Titrant suction pipe SQFT n 03 Pump delivery/auto-level pipe SQFT n 01 BNC/S7 cable for ph electr., L = 3m SQFT n 01 Flushtrode PH electrode HIFM SUGARSΔ with AS22 autosampler, with external oxidation/cooling of samples: n 01 Act 2 burettes 3 pumps SQTV n 02 Burette titrant delivery pipe SQFT n 02 Titrant suction pipe SQFT n 03 Pump delivery pipe SQFT n 01 BNC/S7 cable, L =3m SQFT n 01 Redox Pt combined electrode HIFM n ml Pyrex glass vesse SQUA043914

5 SUGARSΔ with AST22 thermostatable autosampler, with automatic oxidation/cooling of samples: n 01 ACT 2 burettes 3 pumps SQTV n 02 Burette titrant delivery pipe SQFT n 02 Titrant suction pipe SQFT n 03 Pump delivery pipe SQFT n 01 BNC/S7 cable, L = 3m SQFT n 01 Redox Pt combined electrode HIFM n 01 AST22 16-positions autosampler SQTR n ml Pyrex glass vessel SQUA ph/ TOTAL ACIDITY/FREE, TOTAL AND COMBINED S02/SUGARSΔ with AS22 autosampler, auto-level sampling system, with external oxidation/cooling of samples: n 01 ACT 4 burettes 5 pumps SQTV n 04 Burette titrant delivery pipe SQFT n 04 Titrant suction pipe SQFT n 05 Pump delivery/auto-level pipe SQFT n 02 BNC/S7 cable, L = 3m SQFT n 01 Flushtrode ph electrode HIFM n 01 Redox Pt combined electrode HIFM04354 n ml Pyrex glass vessel SQUA ph/total ACIDITY/FREE, TOTAL AND COMBINED S02/SUGARSΔ with AST22 thermostatable autosampler, auto-level sampling system, with automatic oxidation/cooling of samples: n 01 ACT 4 burettes 5 pumps SQTV n 04 Burette titrant delivery pipe SQFT n 04 Titrant suction pipe SQFT n 05 Pump delivery/auto-level pipe SQFT n 02 BNC/S7 cable, L = 3m SQFT n 01 Flushtrode ph electrode HIFM n 01 Redox Pt combined electrode HIFM n 01 AST22 16-positions autosampler SQTR n ml Pyrex glass vessel SQUA043914

6 Accessories: KIT ACCESSORIES FOR OXIDATION/COOLING IN REDUCING SUGARS ANALYSIS (essential for versions with external oxidation/cooling of samples and recommended for versions with automatic oxidation/cooling too): n 01 Steel support for 8 vessels CISM n 01 Steel basin for cooling CISM n 01 CERAN 33 x 33cm heating plate MAMI AUTO-INSTALLINGΔEXTRA BURETTE KIT: n 01 ACT burette unit SQFV n 01 Burette titrant delivery pipe SQFT n 01 Titrant suction pipe SQFT AUTO-INSTALLINGΔ EXTRA PERISTALTIC PUMP (DELIVERY/AUTO- LEVEL) KIT: n 01 ACT peristaltic pump unit SQFV n 01 Pump delivery/auto-level pipe SQFT PRINTER KIT: n 01 Epson Lx300+II PIN printer, 80 col. CDDS n 01 Titrex-printer parallel cable CDDS n 01 Continuous mod. paper, 500 sheets SQFV SOFTWARE FOR DATA ACQUISITION ON PC: n 01 Data acquisition on PC software SQFV n 01 USB/USB connection cable Titrex-PC SQFV REAGENTS: KIT REAGENTS FOR ph/total ACIDITY ANALYSIS: n 01 1 x 250ml ph 4 buffer PAPE n 01 1 x 250ml ph 7 buffer PAPE n 01 1 x 100ml KCL 3M HIPE n 01 1 x 1000ml NaOH 0,25N PAPE KIT REAGENTS FOR FREE/TOTAL AND COMBINED SO2 ANALYSIS: n 01 1 x 1000ml H2SO4 25% P/V TIPE n 01 1 x 1000ml NaOH 4N PAPE n 01 Phial for 1L 0.1N iodine prep. PAPE KIT REAGENTS FOR SUGARS ANALYSIS: n 01 1 x 1000ml sodium thiosulphate 1N PAPE n 01 1 x 1000ml H2SO4 25% P/V TIPE n 01 1 x 250g KI salt PAPE n 01 1 x 250g granular pumice stone PAPE n 01 1 x 1000ml Fehling A PAPE n 01 1 x 1000ml Fehling B PAPE019303

Automatic titrators, TitroMatic

Automatic titrators, TitroMatic 112 TitroMatic These are the fourth generation of CRISON titrators. CRISON has over 25 years experience in this field and knows that, for certain applications, the performance and cost of large titrator

More information

Semi-automatic titrators PH-Burette. A great ph-meter with integrated burette. Incredible price! Infinite possibilities

Semi-automatic titrators PH-Burette. A great ph-meter with integrated burette. Incredible price! Infinite possibilities Semi-automatic titrators PH-Burette. A great ph-meter with integrated burette. Incredible price! Infinite possibilities instruments 5 YEARS G U A R A N T E E Quality at a reasonable price The optimum combination

More information

Titration Catalog. Systems and Autosampler

Titration Catalog. Systems and Autosampler Titration Catalog Systems and Autosampler Hanna Instruments Titration Systems Titration is used in analytical chemistry to determine the amount or concentration of a substance, known as the analyte. Titration

More information

Concise laboratory catalogue

Concise laboratory catalogue 2008 Concise laboratory catalogue Portable and bench-top instruments for ph, EC, ISE, DO and C measurements. Simple and advanced models covering from routine measurements to maximum requirements in investigation.

More information

Kjeltec 2300 Analyzer Unit

Kjeltec 2300 Analyzer Unit Kjeltec 2300 Analyzer Unit Automatic distillation and approved colorimetric titration for analysis of Kjeldahl nitrogen/protein, ammonium- nitrogen, TKN, Direct distillation (DD), volatile acids/ bases

More information

Compact Titration Compact Titrator G20. One Click Titration Simple & Dependable

Compact Titration Compact Titrator G20. One Click Titration Simple & Dependable Compact Titration Compact Titrator G20 One Click Titration Simple & Dependable Simplicity The Intelligent Helper for Simple Titrations One Click Titration Intuitive method adaptation Accurate results simply

More information

Compact Titration. Compact Titrator G20. One Click Titration Simple & Dependable

Compact Titration. Compact Titrator G20. One Click Titration Simple & Dependable Compact Titration Compact Titrator G20 One Click Titration Simple & Dependable Simplicity The Intelligent Helper for Simple Titrations One Click Titration Intuitive method adaptation Accurate results simply

More information

Electrochemistry LEC Potentiometric ph titration (phosphoric acid in a soft drink) What you need: What you can learn about

Electrochemistry LEC Potentiometric ph titration (phosphoric acid in a soft drink) What you need: What you can learn about Electrochemistry LEC 06 What you can learn about Galvanic cell Types of electrodes Nernst equation Potentiometry Principle and tasks The cell voltage and the Galvani voltage of the electrodes of an galvanic

More information

Our Drop Counter sensor now features housing for two electrode sensors, an anti-twist mechanism, an indicator LED and two cable guides.

Our Drop Counter sensor now features housing for two electrode sensors, an anti-twist mechanism, an indicator LED and two cable guides. The Drop Counter sensor is an optical sensor that accurately records the number of drops of titrant added during a titration. The Drop Counter sensor software can automatically convert the number of drops

More information

From 1 ppm to 100% Karl Fischer water content determination

From 1 ppm to 100% Karl Fischer water content determination METTLER TOLEDO Karl Fischer Titrators DL39 & DL32 Coulometers DL38 & DL31 Volumeters Oven sample changer Stromboli From 1 ppm to 100% Karl Fischer water content determination Karl Fischer water content

More information

Acceleration, Velocity, Separate probe VIBRATION METER Model : VB-8202

Acceleration, Velocity, Separate probe VIBRATION METER Model : VB-8202 Acceleration, Velocity, Separate probe VIBRATION METER Model : VB-8202 Your purchase of this VIBRATION METER marks a step forward for you into the field of precision measurement. Although this METER is

More information

Automatic Potentiometric Titrator

Automatic Potentiometric Titrator Automatic Potentiometric Titrator AT-610 Automatic Potentiometric Titrator Two Different Titrations can be Performed Simultaneously --- Allow for Space-saving. Also, a Karl Fischer Moisture Titrator can

More information

Easy and reliable KF titrations From 1 ppm to 100%

Easy and reliable KF titrations From 1 ppm to 100% AGC Karl Book Fischer 20% Titrators Cyan Volumetric KF Titrators DL31, DL38 Coulometric KF Titrators DL32, DL39 Oven sample changer Stromboli Easy and reliable KF titrations From 1 ppm to 100% Karl Fischer

More information

The first address for Titration. TITRONIC 300 and TitroLine 5000

The first address for Titration. TITRONIC 300 and TitroLine 5000 The first address for Titration TITRONIC 300 and TitroLine 5000 Selection table titration piston burettes TITRONIC and automatic titrators TitroLine The most important features of titrators TitroLine and

More information

Thermo Scientific Orion Star T900 Series Laboratory Titrators. Potentiometric titrators for performing automated ph, redox, or ion titrations

Thermo Scientific Orion Star T900 Series Laboratory Titrators. Potentiometric titrators for performing automated ph, redox, or ion titrations Thermo Scientific Orion Star T900 Series Laboratory Titrators Potentiometric titrators for performing automated ph, redox, or ion titrations Thermo Scientific Orion Star T900 Series Titrators Automate

More information

Application Bulletin

Application Bulletin No. 292e Application Bulletin Of interest to: Plating industry, semiconductor industry, automotive industry, aeronautic industry, electroless nickel plating, hypophosphite, alkalinity P 9, 10 Determination

More information

Karl-Fischer Titration the method for determining water

Karl-Fischer Titration the method for determining water Karl-Fischer Titration the method for determining water Quite some experienced analyst will be unpleasantly reminded by the pyridine smell, when hearing the name Karl Fischer. However, modern reagents

More information

Electrodes - Connect/Replace. Reagents - Install/Replace. Select method ph electrode calibration. Reagent calibration.

Electrodes - Connect/Replace. Reagents - Install/Replace. Select method ph electrode calibration. Reagent calibration. Short-For t-form Reminders Electrodes - Connect/Replace Reagents - Install/Replace Select method ph electrode calibration Reagent calibration Running methods Running sequences Direct measurements Maintenance

More information

Operating Instructions. Titration Excellence Terminal

Operating Instructions. Titration Excellence Terminal Operating Instructions Titration Excellence Terminal Table of Contents Contents Page 1. Introduction 1 2. Functional Description 3 2.1 Layout of the Terminal 3 2.2 Operating the Touchscreen 4 2.3 The

More information

Reagents - Install/Replace. Select method/sequence. KF Reagent calibration Running KF titration methods. Running SAC sequences

Reagents - Install/Replace. Select method/sequence. KF Reagent calibration Running KF titration methods. Running SAC sequences Short-For t-form Reminders Reagents - Install/Replace Select method/sequence KF Reagent calibration Running KF titration methods Running SAC sequences Maintenance recommendations Storage recommendations

More information

La nueva línea de tituladores y buretas

La nueva línea de tituladores y buretas TITRONIC y TitroLine La nueva línea de tituladores y buretas TITRONIC and TitroLine The new titrators and burettes New from SI Analytics: Simplicity without sacrificing accuracy or features Introducing

More information

Acceleration/Velocity/Displacement VIBRATION METER

Acceleration/Velocity/Displacement VIBRATION METER Acceleration/Velocity/Displacement VIBRATION METER Model : VB-8220 Your purchase of this VIBRATION METER marks a step forward for you into the field of precision measurement. Although this METER is a complex

More information

Experiment C-10 Titration of a Strong Acid and a Strong Base

Experiment C-10 Titration of a Strong Acid and a Strong Base 1 Experiment C-10 Titration of a Strong Acid and a Strong Base Objectives To study the titration process. To follow changes in the ph during the titration process while adding a strong base to a strong

More information

Process Instrumentation analyzers

Process Instrumentation analyzers PCA300 Family Chlorine, ph, ORP and Temperature Analyzers Backlit LCD display Nema 4X protection.10 DPD chlorine measurement method Colorimeter diagnostics Reagent reminder Amplified ph/temperature probe

More information

KEM SET. for Beverage. Gas volume Internal gas pressure Air content Oxygen concentration Inside pressure Density Brix

KEM SET. for Beverage. Gas volume Internal gas pressure Air content Oxygen concentration Inside pressure Density Brix Acidity Alkalinity for Beverage Gas volume Internal gas pressure Air content Oxygen concentration Inside pressure Density Brix Vitamin C Ca & Mg Acidity Vitamin C for Ca & Mg Ca Mg Alkalinity A Automatic

More information

Mobile coulometer for water determination anywhere you want

Mobile coulometer for water determination anywhere you want 899 Coulometer Mobile coulometer for water determination anywhere you want Extremely small & compact Maximum flexibility due to independent power supply Automatic start of titration 899 Coulometer the

More information

Karl Fischer Titrator

Karl Fischer Titrator DOC022.53.90357 Karl Fischer Titrator USER MANUAL 07/2011, Edition 1 HACH Company, 2011. All rights reserved. Printed in Germany Table of contents Section 1 Specifications... 5 Section 2 General information...

More information

USER MANUAL. Aquamax TAN

USER MANUAL. Aquamax TAN Aquamax TAN USER MANUAL GUARANTEE The Aquamax TAN titrators are guaranteed against any manufacturing defect or component failure. GRScientific will repair or replace, free of charge, any defective component

More information

# 12 ph-titration of Strong Acids with Strong Bases

# 12 ph-titration of Strong Acids with Strong Bases # 12 ph-titration of Strong Acids with Strong Bases Purpose: A strong acid solution is titrated with a strong base solution. A titration curve is then used to determine the endpoint and find the concentration

More information

TitroLine alpha plus From precise programmable piston burette to fully automatic titration system

TitroLine alpha plus From precise programmable piston burette to fully automatic titration system LABWARE SCHOTT-GERÄTE TITRATORS AND PISTON BURETTES E EQ EP ppm H 2 O ml EQ TitroLine alpha plus From precise programmable piston burette to fully automatic titration system EP ppm H 2 O ml EQ EP ppm H

More information

CHAPTER 2 MATERIALS AND GENERAL EXPERIMENTAL PROCEDURES

CHAPTER 2 MATERIALS AND GENERAL EXPERIMENTAL PROCEDURES CHAPTER 2 MATERIALS AND GENERAL EXPERIMENTAL PROCEDURES This chapter deals with description of the materials used, experimental conditions employed, and general instrumental and electrode arrangements

More information

Potentiometric measurement of ph

Potentiometric measurement of ph Potentiometric measurement of ph Determination of ph can be done by simple colorimetric methods using acid-base indicators (ph test strips). Nevertheless, the precision of such methods is mostly insufficient.

More information

Operating Instructions. METTLER TOLEDO DL77 / DL70ES / DL67 Titrators RESET EXIT RUN

Operating Instructions. METTLER TOLEDO DL77 / DL70ES / DL67 Titrators RESET EXIT RUN Operating Instructions METTLER TOLEDO DL77 / DL70ES / DL67 Titrators SEL RESET EXIT SEL RUN 1. INSTALLATION 2. EDITOR 3. ANALYSIS 4. AUXILIARY FUNCTIONS 5. DOCUMENTATION 6. USER LEVEL 7. REMOTE CONTROL

More information

425 Jordan Road SOP. No. 10 Rev. No. 1.3 Troy, NY Date: 03/14/2012 Page 1 of 7

425 Jordan Road SOP. No. 10 Rev. No. 1.3 Troy, NY Date: 03/14/2012 Page 1 of 7 Troy, NY 12180 Date: 03/14/2012 Page 1 of 7 USGS New York Water Science Center Soil and Low Ionic Strength Water Quality Laboratory Electrometric Measurements and Titration Standard Operating Procedure

More information

Determination of the Equivalent Weight and the K a or K b for a Weak Acid or Base

Determination of the Equivalent Weight and the K a or K b for a Weak Acid or Base INTRODUCTION Determination of the Equivalent Weight and the K a or K b for a Weak Acid or Base Chemists frequently make use of the equivalent weight (eq. wt.) as the basis for volumetric calculations.

More information

OPERATION MANUAL. 3 in 1, IR, Type K/J/R/E/T, Pt 100 ohm THERMOMETER. Model : TM-2000

OPERATION MANUAL. 3 in 1, IR, Type K/J/R/E/T, Pt 100 ohm THERMOMETER. Model : TM-2000 3 in 1, IR, Type K/J/R/E/T, Pt 100 ohm THERMOMETER Model : TM-2000 Your purchase of this THERMOMETER marks a step forward for you into the field of precision measurement. Although this THERMOMETER is a

More information

12.01 Determination of the isoelectric point of an amino acid (glycine)

12.01 Determination of the isoelectric point of an amino acid (glycine) Biochemistry LEB 12 Determination of the isoelectric point of an amino acid (glycine) What you can learn about Isoelectric point Acidic anions Basic cations Zwitterions Equivalence (inflection) points

More information

INSTRUCTOR RESOURCES

INSTRUCTOR RESOURCES INSTRUCTOR RESOURCES The CCLI Initiative Learning Objectives The objectives of this experiment are to... analyze an acid mixture by titration with NaOH solution. use the MicroLAB interface to gather and

More information

Chloride, HR, Direct Measurement ISE Method Method g/l to 35 g/l Cl Powder Pillow ISA

Chloride, HR, Direct Measurement ISE Method Method g/l to 35 g/l Cl Powder Pillow ISA , 10255 DOC316.53.01322 Direct Measurement ISE Method Method 10255 3.55 g/l to 35 g/l Cl Powder Pillow ISA Scope and Application: For the determination of high concentrations (1 M) of chloride in brine

More information

#13 ph-titration of Weak Acids with Strong Bases

#13 ph-titration of Weak Acids with Strong Bases #13 ph-titration of Weak Acids with Strong Bases Purpose: A weak acid solution is titrated with a strong base solution. A titration curve is then used to identify the unknown acid and to find its concentration.

More information

KEM SET. for FOOD. Salinity. Brix Density Concentration. Acid Value POV. Water Content

KEM SET. for FOOD. Salinity. Brix Density Concentration. Acid Value POV. Water Content Salinity for FOOD Brix Density Concentration Acid Value POV Water Content Vitamin C Acid Value / POV Salinity Vitamin C for FOOD A Automatic Potentiometric Titrator B Automatic Potentiometric Titrator

More information

Titrimetric Determination of EASTMAN Color Developing Agent, CD-3, in Process ECN-2 Developer with Sulfato Cerate

Titrimetric Determination of EASTMAN Color Developing Agent, CD-3, in Process ECN-2 Developer with Sulfato Cerate Titrimetric Determination of EASTMAN Color Developing Agent, CD-3, in Process ECN-2 Developer Sulfato Cerate ECN-0003/1 Process ECN-2 ECP-2B VNF-1/LC RVNP Formulas SD-49 INTRODUCTION This method describes

More information

Karl Fischer Volumetric Titration Theory and Practice

Karl Fischer Volumetric Titration Theory and Practice Karl Fischer Volumetric Titration Theory and Practice - 1 - - when you need to be sure... Table of contents Introduction... 3 Chemical reactions... 3 ph considerations... 4 Volumetric titration... 4 General

More information

VIBRATION METER Acceleration & Velocity Model : VB-8201HA

VIBRATION METER Acceleration & Velocity Model : VB-8201HA VIBRATION METER Acceleration & Velocity Model : VB-8201HA TABLE OF CONTENTS 1. FEATURES... 1 2. SPECIFICATIONS...2 3. FRONT PANEL DESCRIPTION...4 3-1 Display...4 3-2 BNC socket of meter...4 3-3 RMS/PEAK

More information

Measuring Ammonia in Water and Wastewater using the Thermo Scientific Orion Dual Star ph/ise Meter

Measuring Ammonia in Water and Wastewater using the Thermo Scientific Orion Dual Star ph/ise Meter Measuring Ammonia in Water and Wastewater using the Thermo Scientific Orion Dual Star ph/ise Meter Water and Lab Products, Thermo Fisher Scientific Technical Note 505 Key Words Thermo Scientific Orion

More information

Easier Titration at any level of complexity: TitroLine alpha plus

Easier Titration at any level of complexity: TitroLine alpha plus Easier Titration at any level of complexity: TitroLine alpha plus Innovative electrochemistry from the very beginning By developing the glass electrode more than 70 years ago, we laid the foundation for

More information

Experimental Procedure

Experimental Procedure Experimental Procedure Overview The ph meter is used in conjunction with a titration apparatus and a standardized sodium hydroxide solution to determine the molar concentration of a weak acid solution

More information

INFRARED THERMOMETER Model : TM-959

INFRARED THERMOMETER Model : TM-959 LED target light, Emissivity adjustment INFRARED THERMOMETER Model : TM-959 Your purchase of this I N F R A R E D THERMOMETER marks a step forward for you into the field of precision measurement. Although

More information

MERCAPTAN SULFUR IN GASOLINE & KEROSENE AVIATION TURBINE & DISTILLATE FUELS USING ASTM D3227

MERCAPTAN SULFUR IN GASOLINE & KEROSENE AVIATION TURBINE & DISTILLATE FUELS USING ASTM D3227 MERCAPTAN SULFUR IN GASOLINE & KEROSENE AVIATION TURBINE & DISTILLATE FUELS USING ASTM D3227 Titration Application Use For the determination of mercaptan sulfur in a range from 3 mg/kg 100 mg/kg. Required

More information

Chemistry Potentiometric Titration of a Chloride-Iodide Mixture

Chemistry Potentiometric Titration of a Chloride-Iodide Mixture Chemistry 3200 Silver iodide, AgI, is much less soluble than AgCl. The solubility products of the two salts are 9.8 x 10 17 and 1.78 x 10 10, respectively. Therefore, if a mixture of I and Cl is titrated

More information

Mercaptan Sulfur in Gasoline and Kerosene Aviation Turbine and Distillate Fuels

Mercaptan Sulfur in Gasoline and Kerosene Aviation Turbine and Distillate Fuels Application Note Mercaptan Sulfur in Gasoline and Kerosene Aviation Turbine and Distillate Fuels USING ASTM D 3227 Introduction For the determination of mercaptan sulfur in a range from 3 mg/kg 100 mg/kg.

More information

Automated Chloride Determination in Concrete

Automated Chloride Determination in Concrete ETTLER TOLEDO Automated Chloride Determination in Concrete Application 729 High chloride content in concrete may cause degradation and therefore the content needs to be checked on a regular basis. This

More information

ADI 2040 Process Analyzer

ADI 2040 Process Analyzer ADI 2040 Process Analyzer Multi-purpose wet chemical analysis Multi-purpose Wet Chemical Analysis ADI 2040 The Metrohm Applikon ADI 2040 Process Analyzer is a multipurpose wet chemical analyzer, that has

More information

calorimeter heat flow calorimetry, power compensation calorimetry

calorimeter heat flow calorimetry, power compensation calorimetry calorimeter heat flow calorimetry, power compensation calorimetry Atlas simply does it all What is the Atlas Reaction Calorimeter? The Atlas Reaction Calorimeter accurately measures the power and enthalpy

More information

UDK. Distillation Units Series. A Full Range of Solutions for Kjeldahl Distillation LABSOLUTIONS

UDK. Distillation Units Series. A Full Range of Solutions for Kjeldahl Distillation LABSOLUTIONS LABSOLUTIONS UDK Distillation Units Series A Full Range of Solutions for Kjeldahl Distillation ABCD The distillation unit is used to perform nitrogen and protein content analysis according to the Kjeldahl

More information

Titration of a strong acid with a strong base with Cobra4

Titration of a strong acid with a strong base with Cobra4 Titration of a strong acid with a strong base with Cobra4 TEC Related topics Strong and weak acids and bases, ph value, titration curves, equivalence point, potentiometry. Principle Hydrochloric acid is

More information

One-hand ph/temperature measuring instrument

One-hand ph/temperature measuring instrument One-hand ph/temperature measuring instrument testo 205 ph tip embedded in breakage-proof plastic ph Combined penetration tip with temperature probe Maintenance-free gel electrolyte C Measurement tip exchangeable

More information

Application Note #97 Alkalinity and Hardness by Potentiometric Titration Using TRIS Buffer

Application Note #97 Alkalinity and Hardness by Potentiometric Titration Using TRIS Buffer Application Note #97 Alkalinity and Hardness by Potentiometric Titration Using TRIS Buffer Updated July 2017 Introduction: Alkalinity refers to the acid-neutralizing or buffering capacity of a solution.

More information

Total Carboxylic Acid Group Content Applicable Products: Carbopol * Polymers and Pemulen * Polymeric Emulsifiers

Total Carboxylic Acid Group Content Applicable Products: Carbopol * Polymers and Pemulen * Polymeric Emulsifiers LUBRIZOL TEST PROCEDURE TP-1318-A Edition: August, 2010 Total Carboxylic Acid Group Content Applicable Products: Carbopol * Polymers and Pemulen * Polymeric Emulsifiers Scope: This procedure is used for

More information

рн PRO Controller The device is used to control and regulate ph level in hydroponic systems and water preparing units automatically USER MANUAL

рн PRO Controller The device is used to control and regulate ph level in hydroponic systems and water preparing units automatically USER MANUAL рн PRO Controller The device is used to control and regulate ph level in hydroponic systems and water preparing units automatically Complete Set ph PRO Controller - 1 pcs. ph electrode - 1 pcs. Calibration

More information

VIBRATION METER. Instruction Manual.

VIBRATION METER. Instruction Manual. VIBRATION METER 840063 Instruction Manual CONTENTS Title Page I. Introduction... 2 II. Panel Description... 3 III. Operating Instructions A. General Measurement Procedures... 3~4 B. Peak... 5 C. Data Hold...

More information

ISEmax CAS40D. Technical Information

ISEmax CAS40D. Technical Information Technical Information ISEmax CAS40D Online measurement of nutrient parameters Ion-selective electrodes for the continuous measurement of ammonium, nitrate and other ions Application The ion-selective sensor

More information

Automatic determination of the bromine number and the bromine index in petroleum products

Automatic determination of the bromine number and the bromine index in petroleum products Application Bulletin 177/5 e Automatic determination of the bromine number and the bromine Branch General analytical chemistry; organic chemistry; petrochemistry, biofuels; trace analysis; paints, lacquers,

More information

Conductometric Titration & Gravimetric Determination of a Precipitate

Conductometric Titration & Gravimetric Determination of a Precipitate Conductometric Titration & Gravimetric Determination of a Precipitate Experiment 9 In this experiment, you will monitor conductivity during the reaction between sulfuric acid, H2SO4, and barium hydroxide,

More information

ISEmax CAM40/CAS40. Technical Information

ISEmax CAM40/CAS40. Technical Information Technical Information Online measurement of nutrient parameters Ion-selective electrode system for the continuous measurement of ammonium and nitrate Application The ion-selective electrode system works

More information

User instructions. Gel filled ORP/Redox electrode: Model MTC10101, MTC10103, MTC10105, MTC10110, MTC10115 or MTC10130

User instructions. Gel filled ORP/Redox electrode: Model MTC10101, MTC10103, MTC10105, MTC10110, MTC10115 or MTC10130 User instructions Gel filled ORP/Redox electrode: Model MTC10101, MTC10103, MTC10105, MTC10110, MTC10115 or MTC10130 Safety Information DOC272.53.80033 Precautionary Labels Read all labels and tags attached

More information

Operating Instructions for Ammonium ISE Specifications

Operating Instructions for Ammonium ISE Specifications Operating Instructions for Ammonium ISE Specifications Range: The Ammonium Electrode responds to uncomplexed ion activity over the range 1 x 10-1M to 1 x 10-6M. Linear detection limit is about 10-5M Interference's:

More information

Atlas Syringe Pump XL

Atlas Syringe Pump XL Atlas Syringe Pump XL Batch chemistry application note control of an un-buffered solution using the Atlas Syringe Pump XL Version: 1.0 Issue Date: 21/03/2018 Author: SJH 1 Summary 2 Introduction 2.1 Equipment

More information

Dispensers/Dilutors REPIPET DISPENSERS REPIPET DILUTORS PIPETS OUR BEST ALL GLASS DISPENSERS! OUR LOWEST PRICED DISPENSERS! VIRTUALLY UNBREAKABLE!

Dispensers/Dilutors REPIPET DISPENSERS REPIPET DILUTORS PIPETS OUR BEST ALL GLASS DISPENSERS! OUR LOWEST PRICED DISPENSERS! VIRTUALLY UNBREAKABLE! S E L E C T I O N G U I D E Dispensers/Dilutors OUR BEST DISPENSERS! REPIPET DISPENSERS VIRTUALLY UNBREAKABLE! OUR BEST ALL GLASS DISPENSERS! OUR LOWEST PRICED DISPENSERS! Dispenser Reagent Product Volume

More information

O H 3 O 1 1 A. O 1 1 OH (K w

O H 3 O 1 1 A. O 1 1 OH (K w CHAPTER 8 Acid Base Titration Curves Objectives The objectives of this experiment are to: Understand the titration curves for the following solutions: a strong acid: hydrochloric acid, HCl. a weak acid:

More information

Acid-Base Titration. Evaluation copy

Acid-Base Titration. Evaluation copy Acid-Base Titration Computer 7 A titration is a process used to determine the volume of a solution that is needed to react with a given amount of another substance. In this experiment, your goal is to

More information

Application Note #119 Alkalinity and Chloride by Titration

Application Note #119 Alkalinity and Chloride by Titration Application Note #119 Alkalinity and Chloride by Titration Updated July 2017 Introduction: The alkalinity of water may be defined as its capacity to neutralize acid. Alkali substances in water include

More information

ION SELECTIVE MEASUREMENT

ION SELECTIVE MEASUREMENT Electrodes Solutions Instrumentation ION SELECTIVE MEASUREMENT catalog featuring our full line of Ion Selective Electrodes Introduction Hanna Instruments Ion Selective Measurement Catalog Authorized Distributor

More information

METHOD 9040B. ph ELECTROMETRIC MEASUREMENT

METHOD 9040B. ph ELECTROMETRIC MEASUREMENT METHOD 9040B ph ELECTROMETRIC MEASUREMENT 1.0 SCOPE AND APPLICATION 1.1 Method 9040 is used to measure the ph of aqueous wastes and those multiphase wastes where the aqueous phase constitutes at least

More information

This lab will be conducted in groups but the lab report must be completed and submitted individually.

This lab will be conducted in groups but the lab report must be completed and submitted individually. CHM 106 Potentiometric Titration of Phosphoric Acid BACKGROUND Potentiometric titrations are a useful method of determining unknown concentrations in many different types of chemical systems. They may

More information

POLYPHOSPHORIC ACID ASSAY

POLYPHOSPHORIC ACID ASSAY POLYPHOSPHORIC ACID ASSAY Introduction This Technical Information Report describes the sampling technique and method of analysis recommended to perform rapid and reliable polyphosphoric acid assays for

More information

Ka of Unknown Acid In this experiment you will determine the Ka of an unknown acid by titration with the sodium hydroxide.

Ka of Unknown Acid In this experiment you will determine the Ka of an unknown acid by titration with the sodium hydroxide. Ka of Unknown Acid In this experiment you will determine the Ka of an unknown acid by titration with the sodium hydroxide. Because you will be titrating an unknown acid again, you will be using many of

More information

Chapter 12 Tex-617, Determining Chloride in Concrete

Chapter 12 Tex-617, Determining Chloride in Concrete Chapter 12 Tex-617, Determining Chloride in Contents: Section 1 Overview... 12-2 Section 2 Apparatus... 12-3 Section 3 Preparing Solutions... 12-4 Section 4 Procedures... 12-5 Section 5 Calculations...

More information

WATER ANALYSIS The ph Value. The Redox Potential. ALMEMO ph and Redox Measurement. The Electrical Conductivity

WATER ANALYSIS The ph Value. The Redox Potential. ALMEMO ph and Redox Measurement. The Electrical Conductivity www.ahlborn.com WATER ANALYSIS The ph Value The ph value is a logarithmic measure for the concentration of the H ions in a hydrous solution and indicates, by a numerical value, whether the solution has

More information

6 Acid Base Titration

6 Acid Base Titration E x p e r i m e n t Acid Base Titration Experiment : http://genchemlab.wordpress.com/-titration/ objectives To understand the concept of titration. To explain the difference between the analyte and standard

More information

Application Bulletin

Application Bulletin No. 312e Application Bulletin Of interest to: Paper & pulp, card board, wood, process, production, potentiometry, titration, liquor, white, green, black, total, effective, active, alkali, sulphate, sulphide

More information

Tex-620-J, Determining Chloride and Sulfate Contents in Soil

Tex-620-J, Determining Chloride and Sulfate Contents in Soil Contents in Soil Contents: Section 1 Overview...2 Section 2 Sample Preparation...3 Section 3 Ion Chromatography Method...5 Section 4 Wet Chemical Method...9 Section 5 Archived Versions...15 Texas Department

More information

hydrideicp Hydride Generation System

hydrideicp Hydride Generation System HG-MP2-4-A hydrideicp Generation System hydrideicp Hydride Generation System User Manual MP 2 hydrideicp Generation System Elemental Scientific Phone: 1.402.991.7800 Email: esi@icpms.com 1500 North 24th

More information

Standardizing a Solution of Sodium Hydroxide. Evaluation copy

Standardizing a Solution of Sodium Hydroxide. Evaluation copy Standardizing a Solution of Sodium Hydroxide Computer 6 It is often necessary to test a solution of unknown concentration with a solution of a known, precise concentration. The process of determining the

More information

User Manual. Compact Titrator G10S/G20S

User Manual. Compact Titrator G10S/G20S User Manual Compact Titrator G10S/G20S Table of Contents 1 Introduction 3 2 Safety information 4 2.1 Definition of signal words and warning symbols... 4 2.2 Product-specific safety notes... 4 3 Design

More information

Determination of the Equivalent Weight and Ionization Constant of a Weak Acid

Determination of the Equivalent Weight and Ionization Constant of a Weak Acid Determination of the Equivalent Weight and Ionization Constant of a Weak Acid Introduction: The object of this experiment will be to determine the ionization constant, K a, and the equivalent weight of

More information

PURCHASE DIVISION DEPARTMENT QUALITY MANUAL. CPRI Section II -Technical Specification

PURCHASE DIVISION DEPARTMENT QUALITY MANUAL. CPRI   Section II -Technical Specification Revision No. : 02 Dt of Revision : 17.9.2012 Issued by : Q A Section : 0 Topic : FORMAT 6 OF PROCUREMENT PROCEDURE OF CPRI (NON-WORKS) Tender Enquery No : PUR/DMD-33/16-17 Name of the Equipment: Auto Titrator

More information

Guide to ph Analysis.

Guide to ph Analysis. Guide to ph Analysis. XX Why Contents ph Matters Table of Contents Why ph Matters pg 4 What You Need pg 6 How to Measure pg 14 Slope and offset pg 18 Checklist pg 20 Best Practices pg 21 2 Guide to ph

More information

CHEMICAL ENGINEERING LABORATORY CHEG 4137W/4139W. Reaction Kinetics Saponification of Isopropyl Acetate with Sodium Hydroxide

CHEMICAL ENGINEERING LABORATORY CHEG 4137W/4139W. Reaction Kinetics Saponification of Isopropyl Acetate with Sodium Hydroxide CHEMICAL ENGINEERING LABORATORY CHEG 4137W/4139W Reaction Kinetics Saponification of Isopropyl Acetate with Sodium Hydroxide Objective: The purpose of this experiment is to examine and determine the reaction

More information

Measurements with Ion Selective Electrodes: Determination of Fluoride in Toothpaste

Measurements with Ion Selective Electrodes: Determination of Fluoride in Toothpaste Experiment ISE: Measurements with Ion Selective Electrodes: Determination of Fluoride in Toothpaste 67 You have been hired by the government to check the fluoride concentration labelling on some major

More information

Operating Instructions. EasyPlus Titration Easy KFV

Operating Instructions. EasyPlus Titration Easy KFV Operating Instructions EasyPlus Titration Easy KFV Table of Contents 1 Introduction 5 2 Safety Notes 6 2.1 Definition of Signal Warnings and Symbols 6 2.2 Product Specific Safety Notes 6 3 Design and

More information

Experiment 2: Reaction Stoichiometry by Thermometric Titration

Experiment 2: Reaction Stoichiometry by Thermometric Titration Experiment 2: Reaction Stoichiometry by Thermometric Titration Introduction The net result of a reaction (a chemical change) is summarized by a chemical equation. In order to write a chemical equation,

More information

473-SHX Dew Point Mirror

473-SHX Dew Point Mirror Humidity and Temperature Reference Hygrometer For Temperature up to 125 C Precise and stable chilled mirror dew point mirror technology High temperature optical components High temperature sample fan Cable

More information

Karl Fischer Titration Of Food : Towards Complete Automation

Karl Fischer Titration Of Food : Towards Complete Automation Karl Fischer Titration Of Food : Towards Complete Automation Cosimo A. De Caro, A. Aichert, C. Gordon Mettler-Toledo GmbH, Analytical CH-8603 Schwerzenbach, Switzerland Program Introduction Why water determination

More information

PC Control / Touch Control

PC Control / Touch Control PC Control / Touch Control Version 6.0 / 5.840.0150 New Features Manual 8.840.8007EN Metrohm AG CH-9101 Herisau Switzerland Phone +41 71 353 85 85 Fax +41 71 353 89 01 info@metrohm.com www.metrohm.com

More information

Trihalomethane Formation Potential (THMFP)

Trihalomethane Formation Potential (THMFP) Trihalomethane Formation Potential (THMFP) DOC316.53.01147 THM Plus Method 1 Method 10224 Scope and application: To determine the potential of potable source waters that form trihalomethanes and other

More information

CHEMICAL REACTORS TEACHING EQUIPMENT CEXC

CHEMICAL REACTORS TEACHING EQUIPMENT CEXC CE SERIES: BASIC PROCESS PRINCIPLES CHEMICAL REACTORS TEACHING EQUIPMENT CEXC NOW COMPUTER CONTROLLED AS STANDARD 3 NEW REACTORS AVAILABLE CEXC service unit shown fitted with CEB-MkIII transparent batch

More information

Acid-Base Titration. Volume NaOH (ml) Figure 1

Acid-Base Titration. Volume NaOH (ml) Figure 1 LabQuest 24 A titration is a process used to determine the volume of a solution needed to react with a given amount of another substance. In this experiment, you will titrate hydrochloric acid solution,

More information

Dr. OligoTM DNA / RNA / OLIGO SYNTHESIZERS

Dr. OligoTM DNA / RNA / OLIGO SYNTHESIZERS Dr. OligoTM DNA / RNA / OLIGO SYNTHESIZERS High Throughput Oligo Synthesis Synthesize Cleave Deprotect Desalt Elute Dr. Oligo TM The Dr. Oligo TM High Throughput Oligo Synthesizer is available in four

More information

The first address for Titration. TitroLine 7800

The first address for Titration. TitroLine 7800 The first address for Titration 7800 Selection table titration TITRONIC and The most important features of titrators and piston burettes TITRONIC at-a-glance 7800 - The universal titrator with IDS technology

More information