Tishreen University Journal for Research and Scientific Studies - Basic Sciences Series Vol. ( ) No. ( ) *** pg/ abs M H SO ***

Size: px
Start display at page:

Download "Tishreen University Journal for Research and Scientific Studies - Basic Sciences Series Vol. ( ) No. ( ) *** pg/ abs M H SO ***"

Transcription

1 Tishreen University Journal for Research and Scientific Studies - Basic Sciences Series Vol. ( ) No. ( ) ** * *** pg/ pg/ pg/ HNO H SO H SO * ** *** ٢١٩

2 Tishreen University Journal for Research and Scientific Studies - Basic Sciences Series Vol. ( ) No. ( ) Usage of two matrix modifiers (HNO, H SO ) in direct determination of trace cadmium element in seawater by atomic orption spectrometry with electrothermal atomization. Dr. Issam ohamad * Dr. ohammad Al Shahneh ** Nour Al deen Youssef *** (Received ١٨ / ٣ / ٢٠٠٨. Accepted ٢٥/٥/٢٠٠٨) ABSTRACT This study deals with the effect of a series concentrations of nitric acid and sulfuric acid on atomic orption signal of trace Cd-element in seawater medium in order to determine the optimal concentration of the two studied acids used as matrix modifiers. The thermal study is done in order to determine the optimal temperature of ashing and atomizing stages used in direct determination of trace Cd-element in sweater using standard additions method for GF and GF-PFT technique with deuterium corrector. The results shows a sensitivity of pg/.and pg/.in the presence of HNO and H SO respectively as matrix modifiers for GFtechnique, and pg/. in the presence of H SO as matrix modifier for GF-PFT technique. This method allows to determine trace Cd-element directly in natural seawater. Keywords: ETA-AAS - Seawater - Cadmium element - atrix modifiers (HNO, H SO ) -Deuterium Corrector * Professor, Department of chemistry, Faculty of science, Tishreen University, Lattakia, Syria. ** Professor, Department of chemistry, Faculty of science, Tishreen University, Lattakia, Syria. *** Postgraduate student, Department of chemistry, Faculty of science, Tishreen University, Lattakia, Syria. ٢٢٠

3 Tishreen University Journal. Bas. Sciences Series مجلة جامعة تشرین العلوم الا ساسیة المجلد (٣٠) العدد (٢) ٢٠٠٨ µg/l x µg/l x g/l [ - ] Solvent extraction Ion exchange Coprecipitation [ - ] [ ] ٢٢١

4 AA SHIADZU EYELA CA GFA-EX ASC SR( Self-Reversal ) (Hallow Cathode Lamp). nm nm HNO Cd NaCl,,,,,, NaCl Flow Rate of argon (l/min) Heat ode RAP Time(sec) PFT Coated Temp() PFT Coated RAP RAP STEP ٢٢٢

5 Tishreen University Journal. Bas. Sciences Series مجلة جامعة تشرین العلوم الا ساسیة المجلد (٣٠) العدد (٢) ٢٠٠٨ STEP STEP مولاریة حمض الازوت Cd Cd ٢٢٣

6 تغیرات درجة حرارة الترمید ) ( Cd HNO تغیرات درجة حرارة التذریر ) ( 1 Cd HNO ٢٢٤

7 Tishreen University Journal. Bas. Sciences Series مجلة جامعة تشرین العلوم الا ساسیة المجلد (٣٠) العدد (٢) ٢٠٠٨ NaCl ٢٢٥

8 Ammonium Pyrrolidine Dithio Carbamate APDC CHCl ETA-AAS APDC CHCl ml Cd ml HNO (,,,, ) μl ml Flow Rate of argon (l/min) Heat ode Time(sec) PFT Coated Temp() PFT Coated ٢٢٦

9 Tishreen University Journal. Bas. Sciences Series مجلة جامعة تشرین العلوم الا ساسیة المجلد (٣٠) العدد (٢) ٢٠٠٨ RAP RAP RAP STEP STEP STEP RSD% SD SD RSD% () ٢٢٧

10 ٢٢٨ R 2 = () () A ٠ ٠٣٨

11 Tishreen University Journal. Bas. Sciences Series مجلة جامعة تشرین العلوم الا ساسیة المجلد (٣٠) العدد (٢) ٢٠٠٨ SW SW SW SW SW NaCl,,, NaCl Flow Rate of argon (l/min) Heat ode Time(sec) PFT Coated Temp() PFT Coated ٢٢٩

12 RAP RAP RAP STEP STEP STEP مولاریة حمض الكبریت Cd. Cd ٢٣٠

13 Tishreen University Journal. Bas. Sciences Series مجلة جامعة تشرین العلوم الا ساسیة المجلد (٣٠) العدد (٢) ٢٠٠٨ تغیرات درجة حرارة طور الترمید 4 Cd H SO تغیرات درجة حرارة التذریر 9 Cd H SO - ٢٣١

14 NaCl,,,,, مولاریة حمض الكبریت كقالب تعدیل.3 Cd ٢٣٢

15 Tishreen University Journal. Bas. Sciences Series مجلة جامعة تشرین العلوم الا ساسیة المجلد (٣٠) العدد (٢) ٢٠٠٨ تغیرات درج ة حرارة الترمی د الامتصاص یة Cd H SO الامتصاص یة تغیرات درج ة حرارة الت ذریر Cd H SO ٢٣٣

16 ( ) ml (,,,,, ) ml ml μl Flow Rate of argon (l/min) Heat ode RAP Time(sec) PFT Coated Temp() PFT Coated RAP RAP STEP STEP STEP RSD% SD SD RSD% () ٢٣٤

17 Tishreen University Journal. Bas. Sciences Series مجلة جامعة تشرین العلوم الا ساسیة المجلد (٣٠) العدد (٢) ٢٠٠٨ ٢٣٥

18 Cd () A () R 2 = SW SW SW SW SW SW ٢٣٦

19 Tishreen University Journal. Bas. Sciences Series مجلة جامعة تشرین العلوم الا ساسیة المجلد (٣٠) العدد (٢) ٢٠٠٨ ml ml H SO RSD% SD SD RSD% () ٢٣٧

20 ٢٣٨ R 2 = () () Cd A

21 Tishreen University Journal. Bas. Sciences Series مجلة جامعة تشرین العلوم الا ساسیة المجلد (٣٠) العدد (٢) ٢٠٠٨ SW SW SW SW SW SW (APDC-CHCl ) ٢٣٩

22 (APDC- CHCl ) Platform H SO (APDC-CHCl ) Coated Coated HNO H SO (μg/l) Cd ** - ***(pg/ ) (μg/l) (APDC- CHCl ) (Characteristic ass) *** x x pg ٢٤٠

23 Tishreen University Journal. Bas. Sciences Series مجلة جامعة تشرین العلوم الا ساسیة المجلد (٣٠) العدد (٢) ٢٠٠٨ (Characteristic ass) x pg x HNO pg/ H SO pg/ H SO pg/ Hoenig pg/ Grotti pg/ pg/ pg/ pg/ Solid-phase extraction S, Cassiana pg/ K, Truus ٢٤١

24 HOENIG, ; PUSKARIC, E; CHOISY, P; WARTEL,. Direct determination of high-and mid-volatile elements (Cd, Pb, n) in seawater by electrothermal AAS, Analusis,,,. BOWEN, H. G.. Trace elements in Biochemistry, Academic Press, New York,. GROTTI, ; ABELOSCHI,.L; SOGGIA, F; FRACHE, R. Determination of trace metals in sea-water by electrothermal atomic orption spectrometry following solid-phase extraction: quantification and reduction of residual matrix effects, J.Anal. At. Spectrom,,,. KNOWLES,. ethods for the determination of Cadmium in seawater with zeeman background correction, Varian instruments at work,, AA. TRAN, T. N. Direct determination of As, Cu and Pb in Seawater by zeeman graphite furnace atomic orption spectrometry, Varian instruments at work,, AA. HOENIG, ; HOEYWEGHEN, P. V. Direct determination of g in seawater by ETA-AAS with deuterium background correction using a platform and platinum matrix modifier, Varian instruments at work,, AA. QUIGLEY,. N; VERNON, F. Determination of trace metal ion concentrations in seawater,,,,. HARAGUCHI, H; FUWA, K. arine analysis by atomic orption spectrometry, Atomic Absorption Spectrometry, J. E. Cantle, Elsevier Scientific Company- Amsterdam, Netherlands,,. FAREY, B. J; NELSON, L. A. Water and effluents, Atomic Absorption Spectrometry, J. E. Cantle, Elsevier Scientific Company-Amsterdam, Netherlands,,. EBDON, L. Fin, industrial and other chemicals, Atomic Absorption Spectrometry, J. E. Cantle, Elsevier Scientific Company-Amsterdam, Netherlands,,. GEORGE, C. Y; CHAN, W. T. Determination of lead in a chloride matrix by atomic orption spectrometry using electrothermal vaporization and capacitively coupled plasma atomization, Journal of Analytical Atomic Spectrometry, arch,,. TRUUS, K; VIITAK, A; VAHER, ; UINASAA, U; PAASRAND, K; TUVIKENE,R; LEVANDI,T. Comparative determination of microelements in Baltic seawater and brown algae samples by atomic orption spectrometric and inductively coupled plasma methods, Proc. Estonian Acad. Sci. Chem,,,,. QUIGLEY, N. ; VERNON, F. A matrix modification experiment for use in electrothermal atomic orption spectrometry, Journal of Chemical Education,,,,. ٢٤٢

25 Tishreen University Journal. Bas. Sciences Series مجلة جامعة تشرین العلوم الا ساسیة المجلد (٣٠) العدد (٢) ٢٠٠٨ CIADEVILLA, E. A; WROBEL, K; ALFREDO, S. Capabilities and limitations of different techniques in electrothermal atomic orption spectrometry for direct monitoring of arsenic, cadmium and lead contamination of sea-water, Journal of Analytical Atomic Spectrometry,, ( ),. ARECHAL-ABRA, N. Direct determination of Cd in seawater by graphite furnace-atomic orbance spectrometry with Zeeman-effect background correction, Geoscience Reports of Shizuoka University,,, VOLYNSKY, A. B; AKAN, S; DOGAN, C. E; KOKLU, U. Application of colloidal palladium modifier for the determination of As, Sb and Pb in a spiced sea water sample by electrothermal atomic orption spectrometry. Spectrochim. Acta, Part B,,,.. ; ; CASSIANA, S. N; PAULO, R.. C; PEDRO, V. O; ELISABETH, O. W+Rh as permanent chemical modifier in simultaneous atomic orption spectrometry: Interference studies on As, Cd, Pb and Se determination, J. Braz. Chem. Soc.,,,. ٢٤٣

26 ٢٤٤

Tishreen University Journal for Research and Scientific Studies - Basic Sciences Series Vol. ( ) No. ( ) ETA-AAS

Tishreen University Journal for Research and Scientific Studies - Basic Sciences Series Vol. ( ) No. ( ) ETA-AAS Tishreen University Journal for Research and Scientific Studies - Basic Sciences Series Vol. ( ) No. ( ) ETA-AAS pg/ pg/ HNO HNO ١٠٧ ETA-AAS Tishreen University Journal for Research and Scientific Studies

More information

A New Cross-Shaped Graphite Furnace with Ballast Body for Reduction of Interferences in Atomic Absorption Spectrometry

A New Cross-Shaped Graphite Furnace with Ballast Body for Reduction of Interferences in Atomic Absorption Spectrometry http://www.e-journals.net ISSN: 0973-4945; CODEN ECJHAO E- Chemistry 2010, 7(S1), S127-S130 A New Cross-Shaped Graphite Furnace with Ballast Body for Reduction of Interferences in Atomic Absorption Spectrometry

More information

Tishreen University Journal for Research and Scientific Studies - Arts and Humanities Series Vol. (31) No. (1) 2009

Tishreen University Journal for Research and Scientific Studies - Arts and Humanities Series Vol. (31) No. (1) 2009 2009(1) (31) _ Tishreen University Journal for Research and Scientific Studies - Arts and Humanities Series Vol. (31) No. (1) 2009 ( ) * ** (2009 / 2 / 18.2008 / 10 / 27 ) ) ( ) : ( ) (......... :. -.

More information

Prof. Dr. Biljana Škrbić, Jelena Živančev

Prof. Dr. Biljana Škrbić, Jelena Živančev 5 th CEFSER Training Course Analysis of chemical contaminants in food and the environment Faculty of Technology, University of Novi Sad, Novi Sad, Republic of Serbia 7-11 May 2012 Analysis of heavy elements

More information

Determination of Pb, Cd, Cr and Ni in Grains Based on Four Chinese National Methods via Zeeman GFAAS

Determination of Pb, Cd, Cr and Ni in Grains Based on Four Chinese National Methods via Zeeman GFAAS Determination of Pb, Cd, Cr and Ni in Grains Based on Four Chinese National Methods via Zeeman GFAAS Application Note Food Testing Author John Cauduro Agilent Technologies, Australia Introduction Trace

More information

9/13/10. Each spectral line is characteristic of an individual energy transition

9/13/10. Each spectral line is characteristic of an individual energy transition Sensitive and selective determination of (primarily) metals at low concentrations Each spectral line is characteristic of an individual energy transition 1 Atomic Line Widths Why do atomic spectra have

More information

The Measurement of Lead in Food Products by Graphite Furnace AA and SpectraAA-40

The Measurement of Lead in Food Products by Graphite Furnace AA and SpectraAA-40 The Measurement of Lead in Food Products by Graphite Furnace AA and SpectraAA-40 Application Note Atomic Absorption Author Keith Brodie The widespread use of metals in modern industry has meant that traces

More information

Determination of cadmium, copper and lead in soils, sediments and sea water samples by ETAAS using a Sc + Pd + NH 4 NO 3 chemical modifier

Determination of cadmium, copper and lead in soils, sediments and sea water samples by ETAAS using a Sc + Pd + NH 4 NO 3 chemical modifier Talanta 65 (2005) 672 677 Determination of cadmium, copper and lead in soils, sediments and sea water samples by ETAAS using a Sc + Pd + NH 4 NO 3 chemical modifier Orhan Acar Department of Nuclear Chemistry,

More information

NOTICE: This method: The laboratories have to study the instrumental conditions appropriate for their own instrumentation.

NOTICE: This method: The laboratories have to study the instrumental conditions appropriate for their own instrumentation. Determination of Cadmium and Lead in powdered infant formula by Electrothermal Atomization Atomic Absorption Spectrometry with Zeeman Effect Correction NOTICE: This method: - has to be considered only

More information

UNIVERSITI SAINS MALAYSIA. Second Semester Examination Academic Session 2004/2005. March KAA 502 Atomic Spectroscopy.

UNIVERSITI SAINS MALAYSIA. Second Semester Examination Academic Session 2004/2005. March KAA 502 Atomic Spectroscopy. UNIVERSITI SAINS MALAYSIA Second Semester Examination Academic Session 2004/2005 March 2005 KAA 502 Atomic Spectroscopy Time: 3 hours Please make sure this paper consists of FIVE typed pages before answering

More information

Using Polynomial Regression to Objectively Test the Fit of Calibration Curves in Analytical Chemistry

Using Polynomial Regression to Objectively Test the Fit of Calibration Curves in Analytical Chemistry International Journal of Applied Mathematics and Theoretical Physics 2015; 1(2): 14-18 Published online February 8, 2016 (http://www.sciencepublishinggroup.com/j/ijamtp) doi: 10.11648/j.ijamtp.20150102.11

More information

Annex B: Monitoring methods, accuracy, detection limits and precision

Annex B: Monitoring methods, accuracy, detection limits and precision Annex B: Monitoring methods, accuracy, detection limits and precision All stations reporting to HELCOM conduct daily sampling of nitrogen compounds in air and in precipitation. The monitoring regime for

More information

LEAD(II) AND COBALT(III) HEPTHYLDITHIOCARBAMATES AS NEW COFLOTATION REAGENTS FOR PRECONCENTRATION OF CADMIUM BEFORE ITS ETAAS DETERMINATION

LEAD(II) AND COBALT(III) HEPTHYLDITHIOCARBAMATES AS NEW COFLOTATION REAGENTS FOR PRECONCENTRATION OF CADMIUM BEFORE ITS ETAAS DETERMINATION LEAD(II) AND COBALT(III) HEPTHYLDITHIOCARBAMATES AS NEW COFLOTATION REAGENTS FOR PRECONCENTRATION OF CADMIUM BEFORE ITS ETAAS DETERMINATION TRAJČE STAFILOV, GORICA PAVLOVSKA AND KATARINA ČUNDEVA Institute

More information

Graphite Furnace Tubes

Graphite Furnace Tubes Graphite Furnace Tubes Quality Raw Materials for Long Life and Performance CPI graphite tubes are produced from one of the highest grades of spectrally pure graphite available today. Prior to use, the

More information

Direct Determination of Cadmium and Lead in honey by Electrothermal Atomization Atomic Absorption Spectrometry with Zeeman Effect Correction

Direct Determination of Cadmium and Lead in honey by Electrothermal Atomization Atomic Absorption Spectrometry with Zeeman Effect Correction NOTICE: This method: Direct Determination of Cadmium and Lead in honey by Electrothermal Atomization Atomic Absorption Spectrometry with Zeeman Effect Correction - has to be considered only as guideline

More information

Direct Analysis of Photoresist Using Inductively Coupled Plasma Mass Spectrometry (ICP-MS) Application

Direct Analysis of Photoresist Using Inductively Coupled Plasma Mass Spectrometry (ICP-MS) Application Direct Analysis of Photoresist Using Inductively Coupled Plasma Mass Spectrometry (ICP-MS) Application Semiconductor Author Junichi Takahashi Koichi Yono Agilent Technologies, Inc. 9-1, Takakura-Cho, Hachioji-Shi,

More information

Determination of Cd and Pb in seawater by graphite furnace atomic absorption spectrometry with the use of hydrofluoric acid as a chemical modifier

Determination of Cd and Pb in seawater by graphite furnace atomic absorption spectrometry with the use of hydrofluoric acid as a chemical modifier Spectrochimica Acta Part B 57 (00) 513 54 Determination of Cd and Pb in seawater by graphite furnace atomic absorption spectrometry with the use of hydrofluoric acid as a chemical modifier J.Y. Cabon*

More information

Extraction of Ultra Trace Amounts Bismuth in Water Samples Using Cloud Point Extraction with 2-Amino-Cyclopentene-1-Dithiocarboxylic Acid

Extraction of Ultra Trace Amounts Bismuth in Water Samples Using Cloud Point Extraction with 2-Amino-Cyclopentene-1-Dithiocarboxylic Acid J. Chemical Health Risks 2(1): 233, 212 Journal of Chemical Health Risks 2(1); 233 212 Extraction of Ultra Trace Amounts Bismuth in Water Samples Using Cloud Point Extraction with 2AminoCyclopentene1Dithiocarboxylic

More information

Atomic Absorption & Atomic Fluorescence Spectrometry

Atomic Absorption & Atomic Fluorescence Spectrometry Atomic Absorption & Atomic Fluorescence Spectrometry Sample Atomization Atomic Absorption (AA) Atomic Fluorescence (AF) - Both AA and AF require a light source - Like Molecular Absorption & Fluorescence,

More information

Electrothermal atomic absorption spectrometry behavior of cadmium without/with spiral tungsten filaments as platform technique and its application

Electrothermal atomic absorption spectrometry behavior of cadmium without/with spiral tungsten filaments as platform technique and its application Available online at www.derpharmachemica.com Scholars Research Library Der Pharma Chemica, 2012, 4(6):2169-2177 (http://derpharmachemica.com/archive.html) ISSN 0975-413X CODEN (USA): PCHHAX Electrothermal

More information

The Determination of Toxic, Trace, and Essential Elements in Food Matrices using THGA Coupled with Longitudinal Zeeman Background Correction

The Determination of Toxic, Trace, and Essential Elements in Food Matrices using THGA Coupled with Longitudinal Zeeman Background Correction application Note Atomic Absorption Authors David Bass Senior Product Specialist Cynthia P. Bosnak Senior Product Specialist PerkinElmer, Inc. Shelton, CT 06484 USA The Determination of Toxic, Trace, and

More information

Ch. 9 Atomic Absorption & Atomic Fluorescence Spectrometry

Ch. 9 Atomic Absorption & Atomic Fluorescence Spectrometry Ch. 9 Atomic Absorption & Atomic Fluorescence Spectrometry 9.1 9A. Atomization Most fundamental for both techniques. Typical types 1. flame - burner type 2. Electrothermal graphite furnace 3. Specialized

More information

CH. 21 Atomic Spectroscopy

CH. 21 Atomic Spectroscopy CH. 21 Atomic Spectroscopy 21.1 Anthropology Puzzle? What did ancient people eat for a living? Laser Ablation-plasma ionization-mass spectrometry CH. 21 Atomic Spectroscopy 21.2 plasma In Atomic Spectroscopy

More information

ATOMIC SPECROSCOPY (AS)

ATOMIC SPECROSCOPY (AS) ATOMIC ABSORPTION ANALYTICAL CHEMISTRY ATOMIC SPECROSCOPY (AS) Atomic Absorption Spectroscopy 1- Flame Atomic Absorption Spectreoscopy (FAAS) 2- Electrothermal ( Flame-less ) Atomic Absorption Spectroscopy

More information

Unité d Agronomie, Centre de recherches INRA de Bordeaux, B.P. 81, Villenave d Ornon Cedex, France

Unité d Agronomie, Centre de recherches INRA de Bordeaux, B.P. 81, Villenave d Ornon Cedex, France Analusis, 1999, 27, 813-820 EDP Sciences, Wiley-VCH 1999 Matrix effects during trace elements analysis in plant samples by inductively coupled plasma atomic emission spectrometry with axial view configuration

More information

ELEMENTAL ANALYSIS OF GLASS EXAMINATIONS (PART 1) Module 4

ELEMENTAL ANALYSIS OF GLASS EXAMINATIONS (PART 1) Module 4 ELEMENTAL ANALYSIS OF GLASS EXAMINATIONS (PART 1) Module 4 Tatiana Trejos, M.Sc Florida International University Department of Chemistry and Biochemistry International Forensic Research Institute Outline

More information

Seawater Extraction Procedure for Trace Metals

Seawater Extraction Procedure for Trace Metals Title: Seawater Extraction Page 1 of 10 Seawater Extraction Procedure for Trace Metals References: Danielson, L., B. Magnusson, and S. Westerlund. 1978. An improved metal extraction procedure for the determination

More information

Application of total reflection X-ray fluorescence spectrometry for trace elemental analysis of rainwater

Application of total reflection X-ray fluorescence spectrometry for trace elemental analysis of rainwater PRAMANA c Indian Academy of Sciences Vol. 76, No. 2 journal of February 2011 physics pp. 361 366 Application of total reflection X-ray fluorescence spectrometry for trace elemental analysis of rainwater

More information

Determination of Cu, Zn, Cd and Pb in sh samples by slurry sampling electrothermal vaporization inductively coupled plasma mass spectrometry

Determination of Cu, Zn, Cd and Pb in sh samples by slurry sampling electrothermal vaporization inductively coupled plasma mass spectrometry Analytica Chimica Acta 359 (1998) 205±212 Determination of Cu, Zn, Cd and Pb in sh samples by slurry sampling electrothermal vaporization inductively coupled plasma mass spectrometry Yi-Ching Li, Shiuh-Jen

More information

Detection of iron species using inductively coupled plasma mass spectrometry under cold plasma temperature conditions

Detection of iron species using inductively coupled plasma mass spectrometry under cold plasma temperature conditions Spectrochimica Acta Part B 2001 123128 Analytical note Detection of iron species using inductively coupled plasma mass spectrometry under cold plasma temperature conditions Li-Shing Huang a,b, King-Chuen

More information

Analytical Methods. Electronic Supplementary Information File

Analytical Methods. Electronic Supplementary Information File Electronic Supplementary Material (ESI) for Analytical Methods. This journal is The Royal Society of Chemistry 2014 Analytical Methods Electronic Supplementary Information File Attenuation of interferences

More information

á233ñ ELEMENTAL IMPURITIES PROCEDURES

á233ñ ELEMENTAL IMPURITIES PROCEDURES Second Supplement to USP 38 NF 33 Chemical Tests / á233ñ Elemental Impurities Procedures 1 á233ñ ELEMENTAL IMPURITIES PROCEDURES INTRODUCTION This chapter describes two analytical procedures (Procedures

More information

Selenium Determination in Blood using Zeeman Background Correction and Palladium/Ascorbic Acid Chemical Modification

Selenium Determination in Blood using Zeeman Background Correction and Palladium/Ascorbic Acid Chemical Modification Selenium Determination in Blood using Zeeman Background Correction and Palladium/Ascorbic Acid Chemical Modification Application Note Atomic Absorption Author Michael Knowles Introduction The measurement

More information

Direct Measurement of Metallic Impurities in 20% Ammonium Hydroxide by 7700s/7900 ICP-MS

Direct Measurement of Metallic Impurities in 20% Ammonium Hydroxide by 7700s/7900 ICP-MS Direct Measurement of Metallic Impurities in 20% Ammonium Hydroxide by 7700s/7900 ICP-MS Application Note Semiconductor Authors Junichi Takahashi Agilent Technologies Tokyo, Japan Abstract Ammonium hydroxide

More information

GB Translated English of Chinese Standard: GB

GB Translated English of Chinese Standard: GB Translated English of Chinese Standard: GB31604.34-2016 www.chinesestandard.net Sales@ChineseStandard.net NATIONAL STANDARD OF THE GB PEOPLE S REPUBLIC OF CHINA GB 31604.34-2016 National Food Safety Standard

More information

Direct Determination of Aluminium in Milk by Graphite Furnace Atomic Absorption Spectrometry

Direct Determination of Aluminium in Milk by Graphite Furnace Atomic Absorption Spectrometry Direct Determination of Aluminium in Milk by Graphite Furnace Atomic Absorption Spectrometry NOTICE: This method has been developed by the EURL-CEFAO using the facilities available in its laboratories.

More information

Fast Analysis of Water Samples Comparing Axially-and Radially- Viewed CCD Simultaneous ICP-OES

Fast Analysis of Water Samples Comparing Axially-and Radially- Viewed CCD Simultaneous ICP-OES Fast Analysis of Water Samples Comparing Axially-and Radially- Viewed CCD Simultaneous ICP-OES Application Note Inductively Coupled Plasma-Optical Emission Spectrometers Author Tran T. Nham Introduction

More information

Title Revision No date DETERMINATION OF HEAVY METALS (ARSENIC, CADMIUM, LEAD AND MERCURY) IN COSMETIC PRODUCTS

Title Revision No date DETERMINATION OF HEAVY METALS (ARSENIC, CADMIUM, LEAD AND MERCURY) IN COSMETIC PRODUCTS 1. SCOPE AND FIELD OF APPLICATION The method describes the determination of heavy metals (arsenic, cadmium, lead and mercury) in cosmetic products. 2. PRINCIPLE Organic matter in sample is digested by

More information

Talanta 85 (2011) Contents lists available at ScienceDirect. Talanta. journal homepage:

Talanta 85 (2011) Contents lists available at ScienceDirect. Talanta. journal homepage: Talanta 85 (2011) 415 419 Contents lists available at ScienceDirect Talanta journal homepage: www.elsevier.com/locate/talanta Direct determination of manganese in produced waters from petroleum exploration

More information

P. Perämäki 1*, M. Pesonen 1 and J. Piispanen 2. Introduction

P. Perämäki 1*, M. Pesonen 1 and J. Piispanen 2. Introduction Analusis, 2000, 28, 830-834 EDP Sciences, Wiley-VCH 2000 Development of a microwave sample preparation method for the determination of arsenic in humus and moss samples by graphite furnace atomic absorption

More information

Direct and simultaneous determination of molybdenum and vanadium in sea-water using a multielement electrothermal atomic absorption spectrometer

Direct and simultaneous determination of molybdenum and vanadium in sea-water using a multielement electrothermal atomic absorption spectrometer Direct and simultaneous determination of molybdenum and vanadium in sea-water using a multielement electrothermal atomic absorption spectrometer Pi-Guey Su and Shang-Da Huang* Department of Chemistry,

More information

Mercury, total-in-sediment, atomic absorption spectrophotometry, nameless, direct

Mercury, total-in-sediment, atomic absorption spectrophotometry, nameless, direct 1. Application Mercury, total-in-sediment, atomic absorption spectrophotometry, nameless, direct Parameter and Code: Mercury, total, I-6463-86 (µg/g as Hg): none assigned 1.1 This method is used to analyze

More information

Lecture 7: Atomic Spectroscopy

Lecture 7: Atomic Spectroscopy Lecture 7: Atomic Spectroscopy 1 Atomic spectroscopy The wavelengths of absorbance and emission from atoms in the gas phase are characteristic of atomic orbitals. 2 In the lowest energy transition, the

More information

Atomic Absorption Spectrophotometry. Presentation by, Mrs. Sangita J. Chandratre Department of Microbiology M. J. college, Jalgaon

Atomic Absorption Spectrophotometry. Presentation by, Mrs. Sangita J. Chandratre Department of Microbiology M. J. college, Jalgaon Atomic Absorption Spectrophotometry Presentation by, Mrs. Sangita J. Chandratre Department of Microbiology M. J. college, Jalgaon Defination In analytical chemistry, Atomic absorption spectroscopy is a

More information

Atomic Absorption Spectrometer ZEEnit P series

Atomic Absorption Spectrometer ZEEnit P series Atomic Absorption Spectrometer ZEEnit P series Technical Data ZEEnit series Update 07/2014 OBue 1/ 5 ZEEnit P series Variable high-end AA Spectrometer with Deuterium and Zeeman Background Correction with

More information

Quality Control Procedures for Graphite Furnace AAS using Avanta Software

Quality Control Procedures for Graphite Furnace AAS using Avanta Software Application Note Quality Control Procedures for Graphite Furnace AAS using Avanta Software Introduction With the arrival of quality standards in the analytical laboratory, an ever increasing emphasis is

More information

By Donna L. Damrau U.S. GEOLOGICAL SURVEY. Open-File Report Denver, Colorado

By Donna L. Damrau U.S. GEOLOGICAL SURVEY. Open-File Report Denver, Colorado METHODS OF ANALYSIS BY THE U.S. GEOLOGICAL SURVEY NATIONAL WATER QUALITY LABORATORY-- DETERMINATION OF LOW-LEVEL SILVER BY GRAPHITE FURNACE ATOMIC ABSORPTION SPECTROPHOTOMETRY By Donna L. Damrau U.S. GEOLOGICAL

More information

Trace elemental analysis solutions for your application. June 6, 2018

Trace elemental analysis solutions for your application. June 6, 2018 Trace elemental analysis solutions for your application June 6, 2018 Understanding how each technique works Components of instrument Selection Criteria Application Fields OUTLINE All these techniques can

More information

ABSTRACT: INTRODUCTION

ABSTRACT: INTRODUCTION Methods of Sample Thermal Modification by means Double Vaporization in Two Step Atomizer for Atomic Absorption Analysis. Ilia Grinshtein, Yuri Vilpan, Alexei Saraev and Lubov Vasilieva Russian Research

More information

high temp ( K) Chapter 20: Atomic Spectroscopy

high temp ( K) Chapter 20: Atomic Spectroscopy high temp (2000-6000K) Chapter 20: Atomic Spectroscopy 20-1. An Overview Most compounds Atoms in gas phase high temp (2000-6000K) (AES) (AAS) (AFS) sample Mass-to-charge (ICP-MS) Atomic Absorption experiment

More information

Supporting Information. Facile design of phase separation for microfluidic. droplet-based liquid phase microextraction as a front end to

Supporting Information. Facile design of phase separation for microfluidic. droplet-based liquid phase microextraction as a front end to Supporting Information Facile design of phase separation for microfluidic droplet-based liquid phase microextraction as a front end to electrothermal vaporization-icpms for the analysis of trace metals

More information

Atomic Emission Spectroscopy

Atomic Emission Spectroscopy Atomic Emission Spectroscopy Ahmad Aqel Ifseisi Assistant Professor of Analytical Chemistry College of Science, Department of Chemistry King Saud University P.O. Box 2455 Riyadh 11451 Saudi Arabia Building:

More information

Multielement Determination of Cadmium and Lead in Urine by Simultaneous Electrothermal Atomic Absorption Spectrometry with an End-capped Graphite Tube

Multielement Determination of Cadmium and Lead in Urine by Simultaneous Electrothermal Atomic Absorption Spectrometry with an End-capped Graphite Tube 2003 The Japan Society for Analytical Chemistry 1519 Multielement Determination of Cadmium and Lead in Urine by Simultaneous Electrothermal Atomic Absorption Spectrometry with an End-capped Graphite Tube

More information

HEAVY METALS IN LAKE NAKURU ATOMIC SPECTROSCOPY

HEAVY METALS IN LAKE NAKURU ATOMIC SPECTROSCOPY HEAVY METALS IN LAKE NAKURU ATOMIC SPECTROSCOPY PURPOSE This section will provide an introduction to atomic spectroscopy. The basic concepts of flame atomic absorption spectroscopy (FLAA), graphite furnace

More information

ISO INTERNATIONAL STANDARD. Water quality Determination of trace elements using atomic absorption spectrometry with graphite furnace

ISO INTERNATIONAL STANDARD. Water quality Determination of trace elements using atomic absorption spectrometry with graphite furnace INTERNATIONAL STANDARD ISO 15586 First edition 2003-10-01 Water quality Determination of trace elements using atomic absorption spectrometry with graphite furnace Qualité de l'eau Dosage des éléments traces

More information

spectrophotometric determination of lead in notable water hv matr; k modification

spectrophotometric determination of lead in notable water hv matr; k modification 1. Indian Inst. ci., 64 (B), May 1983, Pp. 121-1i1 c Indian Institute of Science, Printed in India. Short Communication Eithliflati011 of sodium interference in flameless atomic absorption spectrophotometric

More information

Chemistry 311: Instrumentation Analysis Topic 2: Atomic Spectroscopy. Chemistry 311: Instrumentation Analysis Topic 2: Atomic Spectroscopy

Chemistry 311: Instrumentation Analysis Topic 2: Atomic Spectroscopy. Chemistry 311: Instrumentation Analysis Topic 2: Atomic Spectroscopy Atomic line widths: Narrow line widths reduce the possibility of spectral overlap and thus interferences. The band width at half height is used to indicate width. This is also sometimes called the effective

More information

Emission spectrum of H

Emission spectrum of H Atomic Spectroscopy Atomic spectroscopy measures the spectra of elements in their atomic/ionized states. Atomic spectrometry, exploits quantized electronic transitions characteristic of each individual

More information

very high temperature for excitation not necessary generally no plasma/arc/spark AAS

very high temperature for excitation not necessary generally no plasma/arc/spark AAS Atomic Absorption Spectrometry (Chapter 9) AAS intrinsically more sensitive than AES similar atomization techniques to AES addition of radiation source high temperature for atomization necessary flame

More information

TRACE ELEMENT ANALYSIS USING A BENCHTOP TXRF- SPECTROMETER

TRACE ELEMENT ANALYSIS USING A BENCHTOP TXRF- SPECTROMETER Copyright JCPDS - International Centre for Diffraction Data 2005, Advances in X-ray Analysis, Volume 48. 236 ABSTRACT TRACE ELEMENT ANALYSIS USING A BENCHTOP TXRF- SPECTROMETER Hagen Stosnach Röntec GmbH,

More information

Direct Analysis of Trace Metal Impurities in High Purity Nitric Acid Using ICP-QQQ

Direct Analysis of Trace Metal Impurities in High Purity Nitric Acid Using ICP-QQQ Application Note Semiconductor Direct Analysis of Trace Metal Impurities in High Purity Nitric Acid Using ICP-QQQ Authors Kazuo Yamanaka and Kazuhiro Sakai Agilent Technologies, Tokyo, Japan Introduction

More information

Determination Of Pb (II), Cr (VI) And Cd (II) Contents In Some Ethiopia Spices After Microwave Digestion Using Atomic Absorption Spectroscopy

Determination Of Pb (II), Cr (VI) And Cd (II) Contents In Some Ethiopia Spices After Microwave Digestion Using Atomic Absorption Spectroscopy Determination Of Pb (II), Cr (VI) And Cd (II) Contents In Some Ethiopia Spices After Microwave Digestion Using Atomic Absorption Spectroscopy KASSA BELAY Department of Chemistry, Adigrat University, Adigrat,

More information

Talanta 62 (2004) Aristidis N. Anthemidis, George A. Zachariadis, Charalampos G. Farastelis, John A. Stratis

Talanta 62 (2004) Aristidis N. Anthemidis, George A. Zachariadis, Charalampos G. Farastelis, John A. Stratis Talanta 62 (2004) 437 443 On-line liquid liquid extraction system using a new phase separator for flame atomic absorption spectrometric determination of ultra-trace cadmium in natural waters Aristidis

More information

Analysis Repeatability of Trace and Major Elements in a Water Sample

Analysis Repeatability of Trace and Major Elements in a Water Sample Analysis Repeatability of Trace and Major Elements in a Water Sample Agnès COSNIER HORIBA Scientific Longjumeau, France Keywords: environment Elements: Al, As, B, Ba, Ca, Cd, Co, Cr, Cu, Fe, Hg, K, Li,

More information

Optical Atomic Spectroscopy

Optical Atomic Spectroscopy Optical Atomic Spectroscopy Methods to measure conentrations of primarily metallic elements at < ppm levels with high selectivity! Two main optical methodologies- -Atomic Absorption--need ground state

More information

--> Buy True-PDF --> Auto-delivered in 0~10 minutes. GB Translated English of Chinese Standard: GB5009.

--> Buy True-PDF --> Auto-delivered in 0~10 minutes. GB Translated English of Chinese Standard: GB5009. Translated English of Chinese Standard: GB5009.17-2014 www.chinesestandard.net Sales@ChineseStandard.net NATIONAL STANDARD OF GB THE PEOPLE S REPUBLIC OF CHINA National Food Safety Standard-Determination

More information

Key Analytical Issues: Sample Preparation, Interferences and Variability. Tim Shelbourn, Eli Lilly and Company

Key Analytical Issues: Sample Preparation, Interferences and Variability. Tim Shelbourn, Eli Lilly and Company Key Analytical Issues: Sample Preparation, Interferences and Variability Tim Shelbourn, Eli Lilly and Company Presentation Outline Sample preparation objectives and challenges Some common interferences

More information

Trace elemental analysis of distilled alcoholic beverages using the Agilent 7700x ICP-MS with octopole collision/ reaction cell

Trace elemental analysis of distilled alcoholic beverages using the Agilent 7700x ICP-MS with octopole collision/ reaction cell Trace elemental analysis of distilled alcoholic beverages using the Agilent 77x ICP-MS with octopole collision/ reaction cell Application note Food testing Author Glenn Woods Agilent Technologies Cheadle

More information

NATURE AN POLUUTION DEGREE OF WATER ASSETS STUDIED BY INDUCTIVELY COUPLED PLASMA-OPTICAL EMISSION SPECTROSCOPY

NATURE AN POLUUTION DEGREE OF WATER ASSETS STUDIED BY INDUCTIVELY COUPLED PLASMA-OPTICAL EMISSION SPECTROSCOPY NATURE AN POLUUTION DEGREE OF WATER ASSETS STUDIED BY INDUCTIVELY COUPLED PLASMA-OPTICAL EMISSION SPECTROSCOPY I.Chindea, C.Mânzat*, S.Cintă-Pânzaru** Axente-Sever Theoretical HighSchool, Mediaş, Romania

More information

Fundamentals of the ICP-MS Technique and How to Resolve Issues for Pharmaceutical Materials (In 20 Minutes) Tim Shelbourn, Eli Lilly and Company

Fundamentals of the ICP-MS Technique and How to Resolve Issues for Pharmaceutical Materials (In 20 Minutes) Tim Shelbourn, Eli Lilly and Company Fundamentals of the ICP-MS Technique and How to Resolve Issues for Pharmaceutical Materials (In 20 Minutes) Tim Shelbourn, Eli Lilly and Company Why ICP Mass Spectrometry? Ultra-trace multi-element analytical

More information

--> Buy True-PDF --> Auto-delivered in 0~10 minutes. GB Translated English of Chinese Standard: GB5009.

--> Buy True-PDF --> Auto-delivered in 0~10 minutes. GB Translated English of Chinese Standard: GB5009. Translated English of Chinese Standard: www.chinesestandard.net Sales@ChineseStandard.net NATIONAL STANDARD OF THE GB PEOPLE S REPUBLIC OF CHINA GB 5009.15-2014 National Food Safety Standard Determination

More information

Using FIMS to Determine Mercury Content in Sewage Sludge, Sediment and Soil Samples

Using FIMS to Determine Mercury Content in Sewage Sludge, Sediment and Soil Samples A P P L I C A T I O N N ot e Atomic Absorption Using FIMS to Determine Mercury Content in Sewage Sludge, Sediment and Soil Samples Introduction The Flow Injection Mercury System (FIMS) is a dedicated system

More information

INFLUENCE OF THE MEASUREMENT MEDIUM AND MATRIX MODIFIERS ON THE DETERMINATION OF SILICON IN WATERS BY GRAPHITE FURNACE ATOMIC ABSORPTION SPECTROMETRY

INFLUENCE OF THE MEASUREMENT MEDIUM AND MATRIX MODIFIERS ON THE DETERMINATION OF SILICON IN WATERS BY GRAPHITE FURNACE ATOMIC ABSORPTION SPECTROMETRY oujda University Morocco From the SelectedWorks of elhimri2@hotmail.com Spring April 1, 2013 INFLUENCE OF THE MEASUREMENT MEDIUM AND MATRIX MODIFIERS ON THE DETERMINATION OF SILICON IN WATERS BY GRAPHITE

More information

METHOD 7060A ARSENIC (ATOMIC ABSORPTION, FURNACE TECHNIQUE)

METHOD 7060A ARSENIC (ATOMIC ABSORPTION, FURNACE TECHNIQUE) METHOD 7060A ARSENIC (ATOMIC ABSORPTION, FURNACE TECHNIQUE) 1.0 SCOPE AND APPLICATION 1.1 Method 7060 is an atomic absorption procedure approved for determining the concentration of arsenic in wastes,

More information

ANALYTICAL SCIENCES JUNE 1998, VOL The Japan Society for Analytical Chemistry

ANALYTICAL SCIENCES JUNE 1998, VOL The Japan Society for Analytical Chemistry 1998 The Japan Society for Analytical Chemistry 529 Preconcentration of Trace Cadmium from Seawater Using a Dynamically Coated Column of Quaternary Ammonium Salt on C 18 -Bonded Silica Gel and Determination

More information

CHINESE JOURNAL OF FOOD HYGIENE

CHINESE JOURNAL OF FOOD HYGIENE 394 1 2 1 1 3 4 5 1 1 1 1. 510300 2. 510275 3. 526060 4. 526060 5. 517000 4-283. 3 nm - 2. 2% 1. 8 ~ 40. 0 μg /L 0. 5 g 10 ml 0. 036 mg /kg R155. 5 P618. 42 DOI 10. 13590 /j. cjfh. 2015. 04. 010 A 1004-8456

More information

ICP/MS Multi-Element Standards

ICP/MS Multi-Element Standards Standards Ultra Pure Matrix Special Packaging Traceability to National Reference Materials AccuStandard s ICP/MS Standards are formulated to meet the needs of this very special instrument. As matrix effect

More information

Atomic Absorption Spectroscopy

Atomic Absorption Spectroscopy CH 2252 Instrumental Methods of Analysis Unit IV Atomic Absorption Spectroscopy Dr. M. Subramanian Associate Professor Department of Chemical Engineering Sri Sivasubramaniya Nadar College of Engineering

More information

OES - Optical Emission Spectrometer 2000

OES - Optical Emission Spectrometer 2000 OES - Optical Emission Spectrometer 2000 OES-2000 is used to detect the presence of trace metals in an analyte. The analyte sample is introduced into the OES-2000 as an aerosol that is carried into the

More information

Full-text Available Online at and

Full-text Available Online at   and JASEM ISSN 1119-8362 All rights reserved Full-text Available Online at wwwajolinfo and wwwbiolineorgbr/ja J Appl Sci Environ Manage March 2013 Vol 17 (1) 37-41 INFLUENCE OF THE MEASUREMENT MEDIUM AND MATRIX

More information

Analytica Chimica Acta 452 (2002) Received 20 September 2000; received in revised form 14 August 2001; accepted 26 September 2001

Analytica Chimica Acta 452 (2002) Received 20 September 2000; received in revised form 14 August 2001; accepted 26 September 2001 Analytica Chimica Acta 452 (2002) 77 83 Column solid-phase extraction with Chromosorb-102 resin and determination of trace elements in water and sediment samples by flame atomic absorption spectrometry

More information

Preliminary results of a quick, simple method of detecting antimony in water samples

Preliminary results of a quick, simple method of detecting antimony in water samples Cent. Eur. J. Chem. 6(4) 2008 520 525 DOI: 10.2478/s11532-008-0071-y Central European Journal of Chemistry Preliminary results of a quick, simple method of detecting antimony in water samples Short Communication

More information

Atomic Absorption Spectroscopy (AAS)

Atomic Absorption Spectroscopy (AAS) Atomic Absorption Spectroscopy (AAS) Alex Miller ABC s of Electrochemistry 3/8/2012 Contents What is Atomic Absorption Spectroscopy? Basic Anatomy of an AAS system Theory of Operation Practical Operation

More information

MASTERING THE VCE 2014 UNIT 3 CHEMISTRY STUDENT SOLUTIONS

MASTERING THE VCE 2014 UNIT 3 CHEMISTRY STUDENT SOLUTIONS MASTERING THE VCE 2014 UNIT 3 CHEMISTRY STUDENT SOLUTIONS FOR ERRORS AND UPDATES, PLEASE VISIT WWW.TSFX.COM.AU/VCE-UPDATES QUESTION 45 QUESTION 46 Answer is A QUESTION 47 The number of protons in the element.

More information

Use of ICP-MS in analysing radioisotopes. Per Roos Risø National Laboratory for Sustainable Energy, Technicial University of Denmark

Use of ICP-MS in analysing radioisotopes. Per Roos Risø National Laboratory for Sustainable Energy, Technicial University of Denmark Use of ICP-MS in analysing radioisotopes Per Roos Risø National Laboratory for Sustainable Energy, Technicial University of Denmark Inductively Coupled Plasma Mass Spectrometry (ICP-MS) History ICP-AES

More information

Handbook of Inductively Coupled Plasma Spectrometry

Handbook of Inductively Coupled Plasma Spectrometry Handbook of Inductively Coupled Plasma Spectrometry Second Edition MICHAEL THOMPSON, BSc, PhD, ARCS, CChem., FRSC Department of Chemistry Birkbeck College University of London J. NICHOLAS WALSH, BSc, PhD

More information

ICP-OES Application Note Number 35

ICP-OES Application Note Number 35 ICP-OES Application Note Number 35 Rapid measurement of major, minor and trace levels in soils using the Varian 730-ES Vincent Calderon Varian, Inc. Introduction As part of the global strategy for sustainable

More information

Atomic Spectroscopy AA/ICP/ICPMS:

Atomic Spectroscopy AA/ICP/ICPMS: Atomic Spectroscopy AA/ICP/ICPMS: A Comparison of Techniques VA AWWA/VWEA Lab Practices Conference July 25, 2016 Dan Davis Shimadzu Scientific Instruments AA/ICP/ICPMS: A Comparison of Techniques Topics

More information

Reactive fluorescent dye functionalized cotton fabric as a Magic Cloth for selective sensing and reversible separation of Cd 2+ in water

Reactive fluorescent dye functionalized cotton fabric as a Magic Cloth for selective sensing and reversible separation of Cd 2+ in water Electronic Supplementary Material (ESI) for Journal of Materials Chemistry C. This journal is The Royal Society of Chemistry 2015 Supplementary Information Reactive fluorescent dye functionalized cotton

More information

International Journal of Applied Science and Technology Vol. 7, No. 4, December 2017

International Journal of Applied Science and Technology Vol. 7, No. 4, December 2017 International Journal of Applied Science and Technology Vol. 7, No. 4, December 217 Determination of Antimonite (Sb(III)) and Antimonate (Sb(V)) Species using Hydride Generator-Quartz Flame Atomic Absorption

More information

DRAFT EAST AFRICAN STANDARD

DRAFT EAST AFRICAN STANDARD ICS 71.100.70 DRAFT EAST AFRICAN STANDARD Oils for cosmetic industry Methods of test Part 16 : Determination of Heavy metal Content EAST AFRICAN COMMUNITY EAS 2015 First Edition 2015 Copyright notice

More information

UV Spectroscopy Determination of Aqueous Lead and Copper Ions in Water

UV Spectroscopy Determination of Aqueous Lead and Copper Ions in Water UV Spectroscopy Determination of Aqueous Lead and Copper Ions in Water C. H. Tan a, Y. C. Moo a, M. Z. Matjafri a and H. S. Lim a a School of Physics, Universiti Sains Malaysia, 118 Pulau Pinang, Malaysia.

More information

UNITED NATIONS. ENVIRONMENT PROGRAMME MEDITERRANEAN ACTION PLAN 25 May 2015 Original: English. UNEP(DEPI)/ MED WG.417/Inf.14

UNITED NATIONS. ENVIRONMENT PROGRAMME MEDITERRANEAN ACTION PLAN 25 May 2015 Original: English. UNEP(DEPI)/ MED WG.417/Inf.14 UNITED NATIONS UNEP(DEPI)/ MED WG.417/Inf.14 UNITED NATIONS ENVIRONMENT PROGRAMME MEDITERRANEAN ACTION PLAN 25 May 2015 Original: English MED POL Focal Points Meeting Malta, 16-19 June 2015 Joint Session

More information

Characterization of Catalysts and Surfaces. Elemental Analysis (ICP, AAS etc.) Fall Semester 2016 Bodo Hattendorf HCI G105

Characterization of Catalysts and Surfaces. Elemental Analysis (ICP, AAS etc.) Fall Semester 2016 Bodo Hattendorf HCI G105 Outline Characterization of Catalysts and Surfaces Elemental Analysis (ICP, AAS etc.) Fall Semester 2016 Bodo Hattendorf HCI G105 bodo@inorg.chem.ethz.ch Instrumental Methods for Determination of the Elements

More information

BATCH: MATERIAL. Description. water. Quantity QC METAL LL2. is prepared (V/V). Use. be used in the quality. nitric acid is. certificate. intended use.

BATCH: MATERIAL. Description. water. Quantity QC METAL LL2. is prepared (V/V). Use. be used in the quality. nitric acid is. certificate. intended use. Eurofins Miljø A/S Smedeskovvej 38 DK-8464 Galten CERTIFICATE FOR QC METAL LL2 TRACE ELEMENTS/METALSS BATCH: VKI-13-3-0304 INSTRUCTIONS FOR USE OF THE REFERENCE MATERIAL Description This reference material

More information

novaa 800 D Atomic Absorption Spectrometer

novaa 800 D Atomic Absorption Spectrometer Technical Data Atomic Absorption Spectrometer Cpt : +27 (0) 21 905 0476 Jhb : +27 (0) 11 794 Dbn : +27 (0) 31 266 2454 1/7 General The is a compact atomic absorption spectrometer with deuterium background

More information

METHOD 3010A ACID DIGESTION OF AQUEOUS SAMPLES AND EXTRACTS FOR TOTAL METALS FOR ANALYSIS BY FLAA OR ICP SPECTROSCOPY

METHOD 3010A ACID DIGESTION OF AQUEOUS SAMPLES AND EXTRACTS FOR TOTAL METALS FOR ANALYSIS BY FLAA OR ICP SPECTROSCOPY METHOD 3010A ACID DIGESTION OF AQUEOUS SAMPLES AND EXTRACTS FOR TOTAL METALS FOR ANALYSIS BY FLAA OR ICP SPECTROSCOPY 1.0 SCOPE AND APPLICATION 1.1 This digestion procedure is used for the preparation

More information

Validating performance of an Agilent 7800 ICP MS for USP <232>/<233> & ICH Q3D/Q2(R1): Elemental Impurity Analysis in Pharmaceuticals

Validating performance of an Agilent 7800 ICP MS for USP <232>/<233> & ICH Q3D/Q2(R1): Elemental Impurity Analysis in Pharmaceuticals Validating performance of an Agilent 7800 ICP MS for USP / & ICH Q3D/Q2(R1): Elemental Impurity Analysis in Pharmaceuticals Authors Lindsey Whitecotton, Ed McCurdy, Craig Jones and Amir Liba

More information

Simple, reliable analysis of high matrix samples according to US EPA Method 6020A using the Agilent 7700x/7800 ICP-MS

Simple, reliable analysis of high matrix samples according to US EPA Method 6020A using the Agilent 7700x/7800 ICP-MS Simple, reliable analysis of high matrix samples according to US EPA Method 6020A using the Agilent 7700x/7800 ICP-MS Application note Environmental Authors Steve Wilbur, Craig Jones Agilent Technologies,

More information

Tishreen University Journal for Research and Scientific Studies - Arts and Humanities Series Vol. (33) No. (3) 2011.

Tishreen University Journal for Research and Scientific Studies - Arts and Humanities Series Vol. (33) No. (3) 2011. 2011(3) (33) _ Tishreen University Journal for Research and Scientific Studies - Arts and Humanities Series Vol. (33) No. (3) 2011 (Van Hiele) ( ) (2011 / 8 / 4.2011 / 4 / 5 ), ( ) (400) ),.(1994,,,,,

More information