Arak. Power T ransmission Lines. 45 kv

Size: px
Start display at page:

Download "Arak. Power T ransmission Lines. 45 kv"

Transcription

1

2 Arak Power T ransmission Lines 45 kv

3 Arak Power T ransmission Lines. ÄH½kÄpIÄ Swj nhk ni a» nhk»j,

4 Arak Pow er T ransmission L ines 63 kv Towers GNN S4DL T4D60 66 kv Towers 2S 2T 132 kv Towers MS GMS GMSZ HS GT60 D2 D6 DS D9/DT GMSL K4T30 63/230 kv Towers M4S03 M4T10 M4T30 M4T kv Towers LS03 HS10 T30 T60 LSD03 TD30 TD60 LSH03 LAH30 SMA60 SCS03 SLA30 SMA60 GLS03 SLA10 SMA30 SHA60 No.1 No.2 No.3 No.4 No.5 No.6 No.7 No.8 No.9 No.10 No.11 No.12 No.13 No.14 No.15 No.16 No.17 No.18 No.19 No.20 No.21 No.22 No.23 No.24 No.25 No.26 No.27 No.28 No.29 No.30 No.31 No.32 No.33 No.34 No.35 No.36 No.37

5 Arak Pow er T ransmission L ines LS03T LTG LS3G LSD3P LAG MAG 110 kv Towers MS03 T60 No.38 No.39 No.40 No.41 No.42 No.43 No.44 No.45

6

7 Arak Power T ransmission Lines kv

8

9 Arak Power T ransmission Lines

10

11 Arak Power T ransmission Lines kv 4 Ali Abad - Noshahr - Tonekabon Mazandaran Regional Electricity Company Ghods Niroo Consulting Engineers Co.Consultants NRI IRAN 120% (Destruction) Tower Type S4DL - Table of Ultimate Loads - (Kg) Case No *9 Load Case Description High Wind Oblique High Wind Wind & Ice Heavy Ice Uplift High Wind Uplift Oblique Wind Maintenance Cascading Broken Wire Intact Wire Shield Wire V T L KV Conductor Wind on Tower (Kg/m2) V T L * In Case 9 one conuctor and one shield wire shall be broken simultaneously

12 NOTES CLIENT : CONSULTANT : PROJECT : 63 kv Quadreple Circuit Transmission Line 8900 TOWER TYPE : S4DL Arak 30 R400 R R800 R800 R800 R Square Bas e Dimension 5200 Square Bas e Dimension Transverse Face Basic Body, 4m Body Extension, 6m Leg Extension Longitudinal Face Basic Body, 4m Body Extension, 6m Leg Extension

13 Arak Power T ransmission Lines

14

15 Arak Power T ransmission Lines T4D60 T4D60 kv 4 Ali abad- Tonekabon - Noshahr M.R.E.C NRI Iran 114% (High Wind) 2011/10/03 Tower Type T4D60 - Table of Ultimate Loads (Kg) - In 60 Deg. Angle Position Application Case Load Case Description Shield Wire 63 kv Conductor V T L V T L High Wind Oblique High Wind Wind and Ice Heavy Ice Uplift High Wind Uplift Oblique Wind Maintenance Cascading Broken Wire Intact Wire High Wind Oblique High Wind Wind and Ice Heavy Ice Uplift High Wind Uplift Oblique Wind Maintenance

16 NOTES All dimensions are in mm CLIENT : CONSULTANT : Ghods Niroo Consulting Engineers PROJECT : Ali abad - Tonekabon - Noshahr 63 kv Quadruplet Circuit Transmission Line TOWER TYPE : T4D60 Arak Transversal Face Longitudinal Face 9800

17 Arak Power T ransmission Lines

18

19 Arak Power T ransmission Lines 2S 66KV 2 66kV Overhead Transmission Lines LOT 2B Lebanese Ministry of Energy & Water Electricite de France NRI IRAN 109% (Normal Wind) IEC Tower Type 2-S (Lebanon 66 kv Transmission Network Reinforcement) Case No. Case Description Conductor Loads (with Max. Weight Span) V T L Ground Wire Loads (with Max. Weight Span) V T L 1 High Wind Oblique High Wind Wind & Ice Unbalanced Ice High Wind Anti Cacade Broken Wire Intact for BW Unhooking of one cable Anti Cacade 0 Degree Broken Wire 0 Degree Intact for BW 0 Degree

20

21 Arak Power T ransmission Lines

22

23 Arak Power T ransmission Lines 2T 66KV 2 66kV Overhead Transmission Lines LOT 2B Lebanese Ministry of Energy & Water Electricite de France NRI IRAN 120% (Broken Wire on Normal Wind for Phase Conductor-C1) IEC Tower Type 2-S (Lebanon 66 kv Transmission Network Reinforcement) Case No. Case Description Conductor Loads (with Max. Weight Span) V T L Ground Wire Loads (with Max. Weight Span) V T L 1 High Wind Cold Wind Wind & Ice Unbalanced Ice High Wind Broken Wire Intact for BW Unhooking of one cable

24

25 Arak Power T ransmission Lines

26

27 Arak Power T ransmission Lines kv

28

29 Arak Power T ransmission Lines

30

31

32

33

34

35

36

37

38

39

40

41

42

43

44

45

46

47

48

49

50

51

52

53

54

55

56

57

58 132 kv D9/DT

59 Arak Power T ransmission Lines D9/DT D9/DT 132kV 2 Constructionof132/33KVGridstationatALDREEZand Associated132kVOverheadTransmissionLinefrom I BRIGridstation OMANELECTRICITYTRANSMISSIONCOMPANYS.A.O.C MottMacDonald&CompanyL.L.C NRI IRAN ( H ighwind:max.linedeviation(90 )100% IEC LOADING TABLE OF "D9/DT" TOWER Load Case No. Loading Description Conductor Shield Wire Max. Transverse Wind - Max. Vertical Load - Max. Line Deviation (90 ) Max. Transverse Wind - Min. Vertical Load - Max. Line Deviation (90 ) Max. Transverse Wind - Max. Vertical Load - Min. Line Deviation (60 ) Max. Transverse Wind - Min. Vertical Load - Min. Line Deviation (60 ) Broken Wire in Case 1 Broken Wire in Case 2 Broken Wire in Case 3 Broken Wire in Case 4 Full Dead End Condition - Zero Degree Entry Angle - Max. Vertical Load Full Dead End Condition - Zero Degree Entry Angle - Min. Vertical Load Full Dead End Condition - 45 Degrees Entry Angle - Max. Vertical Load Full Dead End Condition - 45 Degrees Entry Angle - Min. Vertical Load Stringing and Maintenance - Max. Line Deviation (90 ) 44,367 9,854 2,038 12,847 1,926 1,163 44,367-4,166 2,038 12, ,163 33,111 9,854 2,038 9,637 1,926 1,163 33,111-4,166 2,038 9, ,163 14,238 4,531 11,529 4, ,288 26,620 5,912 1,223 7,708 1, ,238-1,098 11,529 4, ,288 26,620-2,500 1,223 7, ,862 4,531 14,121 3, ,027 19,867 5,912 1,223 5,782 1, ,862-1,098 14,121 3, ,027 19,867-2,500 1,223 5, ,936 9,854 27,175 1,887 1,926 7,750 5,936-4,166 27,175 1, ,750 25,152 9,854 19,216 7,367 1,926 5,480 25,152-4,166 19,216 7, ,480 5,765 5,912 8,153 1,644 1,155 2,325

60 «½ ع ««ھ ² ج «½ ع ²¹ «¼ ² ±ش

61 Arak Power T ransmission Lines

62 132 kv GMSL

63 Arak Power T ransmission Lines GMSL GMSL 132kV 2 GolshanTabas-ParvadehCoalMineSS I.M.I.D.R.O MoniranPowerConsultimgEngineers NRI IRAN ( W ind&ice)118% IEC Loading Table Tower "GMSL" KG Case No Loading Description High Wind Heavy Ice Wind & Ice Broken in Heavy Ice Ice & Unbalance Wind (HAWK / AW) (OPGW ø 10.5) (HAWK CORE / AW) V T L V T L V T L

64 حغجرز ³³ ز غخك حزر جزغس ششك ï ر خ س و جزغ شف و جزكجشثحزرف و جفغضرخذ 6000 و غذاج خغةرج GMSL «½ ع ««ھ ² ج «½ ع ²¹ «¼ ² ±ش

65 Arak Power T ransmission Lines

66

67

68

69

70

71

72

73

74

75

76

77

78

79

80

81

82

83

84

85

86

87

88

89

90

91

92

93

94

95

96

97

98

99

100

101

102

103

104

105

106

107

108

109

110

111

112

113

114

115

116

117

118

119

120

121

122

123

124

125

126

127

128

129

130

131

132

133

134

135

136

137

138

139

140

141

142

143

144

145

146

147

148

149

150

151

152

153

154

155

156

157

158

159

160

161

162

163

164

165

166

167

168

169

170

171 Arak Power T ransmission Lines LAG 400KV Single Azarbaijan Azarbaijan Regional Electricity Ghods Niroo Power Engineering Consultants NRI IRAN 100% (Wind & Ice) IEC

172 Basic Body, 12m Body Extension, 9m Leg Extension Transverse Face Basic Body, 12m Body Extension, 9m Leg Extension Longitudinal Face

173 Arak Power T ransmission Lines

174

175 Arak Power T ransmission Lines MAG 400KV Single Azarbaijan Azarbaijan Regional Electricity Ghods Niroo Power Engineering Consultants NRI IRAN 100% (Heavy Ice) IEC

176

177 Arak Power T ransmission Lines

178

179

180

181

182

183

184

185

186

APPENDIX I. Line T-198, Structures , over the Ashuelot River, Swanzey, NH

APPENDIX I. Line T-198, Structures , over the Ashuelot River, Swanzey, NH APPENDIX I Line T-198, Structures 122-123, 123-124 over the Ashuelot River, Swanzey, NH 1. The location of this crossing is shown on the attached location map marked as Exhibit Ii. 2. The design and proposed

More information

188 Equating the moments of above two forces about point O, we get, T y = w x x or y = w x T The maximum dip (sag) is represented by the value of y at

188 Equating the moments of above two forces about point O, we get, T y = w x x or y = w x T The maximum dip (sag) is represented by the value of y at 187 Fig. 8.3. (i) shows a conductor suspended between two equilevel supports A and B. The conductor is not fully stretched but is allowed to have a dip. The lowest point on the conductor is O and the sag

More information

Dynamic Simulation on a Broken Test of Conductors

Dynamic Simulation on a Broken Test of Conductors Available online at www.sciencedirect.com Procedia Engineering 31 (2012) 435 440 International Conference on Advances in Computational Modeling and Simulation Dynamic Simulation on a Broken Test of Conductors

More information

A Novel Approach for Increasing the Reliability of Power Transmission Lines in Galloping Conditions

A Novel Approach for Increasing the Reliability of Power Transmission Lines in Galloping Conditions 21, rue d Artois, F-75008 PARIS CIGRE US National Committee http: //www.cigre.org 2014 Grid of the Future Symposium A Novel Approach for Increasing the Reliability of Power Transmission Lines in Galloping

More information

SIGNIFICANCE OF TRANSPOSITION FOR 220KV TOWER

SIGNIFICANCE OF TRANSPOSITION FOR 220KV TOWER International Journal of Latest Research in Science and Technology Volume 4, Issue 5: Page No.4-8, September-October 2015 http://www.mnkjournals.com/ijlrst.htm ISSN (Online):2278-5299 SIGNIFICANCE OF TRANSPOSITION

More information

Influence Analysis of Transmission Lines Insulator on the Conductor Ice-shedding

Influence Analysis of Transmission Lines Insulator on the Conductor Ice-shedding Influence Analysis of Transmission Lines Insulator on the Conductor Ice-shedding Xin-bo HUANG 1, Guan-hua XU 2,Yong-can ZHU 3, Ming-jin LIAO 1,Xin-xin ZHENG 1 1 College of Electronics and Information,

More information

APPENDIX A DEFINITIONS, NOTATIONS, AND SI CONVERSION FACTORS

APPENDIX A DEFINITIONS, NOTATIONS, AND SI CONVERSION FACTORS APPENDIX A DEFINITIONS, NOTATIONS, AND SI CONVERSION FACTORS A.1 DEFINITION OF STRUCTURE TYPES Tangent Structure: Minimum line deflection angle. Usually suspension or some type of post insulators (line

More information

TEST CERTIFICATES OR REPORTS ISSUED BY VEIKI-VNL LTD.

TEST CERTIFICATES OR REPORTS ISSUED BY VEIKI-VNL LTD. Page 2 of 29 TEST CERTIFICATES OR REPORTS ISSUED BY LTD. Type Test Certificate of Complete Type Test This certificate provides the verification of all the rated characteristics of the equipment as assigned

More information

The Lightning Study of Overhead Transmission Lines

The Lightning Study of Overhead Transmission Lines IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE) e-issn: 2278-1676,p-ISSN: 232-3331, Volume 1, Issue 5 Ver. II (Sep Oct. 215), PP 69-75 www.iosrjournals.org The Lightning Study of Overhead

More information

Lightning location system in Croatia

Lightning location system in Croatia Lightning location system in Croatia Dr. sc. Boško Milešević Bojan Franc, dipl. ing. Prof. dr. sc. Ivo Uglešić Izv. prof. dr. sc. Viktor Milardić Dr. sc. Božidar Filipović-Grčić Nina Stipetić, mag. ing.

More information

Overhead lines. 110 kv wood tower with guy wires

Overhead lines. 110 kv wood tower with guy wires Overhead lines a) ja b) 0 kv wood poles c) free standing 0 kv metal tower with I-strings d) free standing 440 kv metal tower with V-strings e) 400 kv metal tower with guy wires 0 kv wood tower with guy

More information

ECE 325 Electric Energy System Components 5 Transmission Lines. Instructor: Kai Sun Fall 2015

ECE 325 Electric Energy System Components 5 Transmission Lines. Instructor: Kai Sun Fall 2015 ECE 325 Electric Energy System Components 5 Transmission Lines Instructor: Kai Sun Fall 2015 1 Content (Materials are from Chapter 25) Overview of power lines Equivalent circuit of a line Voltage regulation

More information

DESIGN AGAINST THE VULNERABILITY OF OVERHEAD TRANSMISSION LINE CAUSED BY GALLOPING

DESIGN AGAINST THE VULNERABILITY OF OVERHEAD TRANSMISSION LINE CAUSED BY GALLOPING DESIGN AGAINST THE VULNERABILITY OF OVERHEAD TRANSMISSION LINE CAUSED BY GALLOPING Miranda Kullolli 1, Genci Sharko and Rejnald Zyfi 1 Mechanical Engineering Faculty, Polytechnic University of Tirana,

More information

TRANSMISSION LINES. All aluminum alloy conductor (AAAC) Aluminum conductor alloy reinforced (ACAR)

TRANSMISSION LINES. All aluminum alloy conductor (AAAC) Aluminum conductor alloy reinforced (ACAR) TRANSMISSION LINES. Transmission Structures An overhead transmission line consists of conductor, insulators, support structures and in most cases shield wires. Overhead power transmission lines are classified

More information

Modern techniques of ice-load assessment and icing maps creation for the design of overhead transmission lines used in the Russian Federation

Modern techniques of ice-load assessment and icing maps creation for the design of overhead transmission lines used in the Russian Federation Modern techniques of ice-load assessment and icing maps creation for the design of overhead transmission lines used in the Russian Federation Vladimir LUGOVOI, Sergey CHERESHNIUK, Larisa TIMASHOVA JSC

More information

Reliability of Transmission Towers under Extreme Wind and Ice Loading

Reliability of Transmission Towers under Extreme Wind and Ice Loading Reliability of Transmission s under Extreme Wind and Ice Loading J. M. EIDINGER and L. KEMPNER JR. G&E Engineering Systems Inc. and Bonneville Power Administration SUMMARY This paper presents reliability

More information

1. Explain the various methods of methods of grounding. In power system, grounding or earthing means connecting frame of electrical equipment (non-cur

1. Explain the various methods of methods of grounding. In power system, grounding or earthing means connecting frame of electrical equipment (non-cur 1. Explain the various methods of methods of grounding. In power system, grounding or earthing means connecting frame of electrical equipment (non-current carrying part) or some electrical part of the

More information

Magnetic and Thermal Analysis of Current Transformer in Normal and Abnormal Conditions

Magnetic and Thermal Analysis of Current Transformer in Normal and Abnormal Conditions Journal of Computer Science 4 (4): 327-332, 2008 ISSN 1549-3636 2008 Science Publications Magnetic and Thermal Analysis of Current Transformer in Normal and Abnormal Conditions 1 M.B.B. Sharifian, 1 M.

More information

SSC-JE EE POWER SYSTEMS: GENERATION, TRANSMISSION & DISTRIBUTION SSC-JE STAFF SELECTION COMMISSION ELECTRICAL ENGINEERING STUDY MATERIAL

SSC-JE EE POWER SYSTEMS: GENERATION, TRANSMISSION & DISTRIBUTION SSC-JE STAFF SELECTION COMMISSION ELECTRICAL ENGINEERING STUDY MATERIAL 1 SSC-JE STAFF SELECTION COMMISSION ELECTRICAL ENGINEERING STUDY MATERIAL Power Systems: Generation, Transmission and Distribution Power Systems: Generation, Transmission and Distribution Power Systems:

More information

Faults on Electrical System. A Research

Faults on Electrical System. A Research Faults on Electrical System A Research Presented to Electrical Engineering School of Engineering and Architecture Mindanao University of Science and Technology Cagayan de Oro City In partial fulfilment

More information

Film Capacitors. EMI suppression capacitors. Date: June 2018

Film Capacitors. EMI suppression capacitors. Date: June 2018 Film Capacitors EMI suppression capacitors Date: June 2018 EPCOS AG 2018. Reproduction, publication and dissemination of this publication, enclosures hereto and the information contained therein without

More information

Methodologies to determine the fault current through an OPGW (OPtical Ground Wire)

Methodologies to determine the fault current through an OPGW (OPtical Ground Wire) ologies to determine the fault current through an OPGW (OPtical Ground Wire) Héctor R. Disenfeld Abstract-- To specify the OPGW (Optical Ground Wire) in a transmission line, it is necessary to know the

More information

EPRI Lightning Protection Design Workstation

EPRI Lightning Protection Design Workstation EPRI Lightning Protection Design Workstation Tom McDermott Electrotek Concepts, Inc. 2000 Winter Power Meeting LPDW v5 Components Includes 1988-97 flash data from the National Lightning Detection Network

More information

Which expression gives the elastic energy stored in the stretched wire?

Which expression gives the elastic energy stored in the stretched wire? 1 wire of length L and cross-sectional area is stretched a distance e by a tensile force. The Young modulus of the material of the wire is E. Which expression gives the elastic energy stored in the stretched

More information

OVERHEAD DESIGN MANUAL

OVERHEAD DESIGN MANUAL OVERHED DESIGN MNUL Section Cable Data pproved by: F. ZINI ENERGEX 2015 MNUL 00302 CLE SELECTION CLE INSULTED CONDUCTORS GUIDELINES For use: in the vicinity of vegetation (present or future) where there

More information

۲۷۹۶ 0 "' ی " #! ۴۳ و م د ; < : ی"98! ی"#"!

۲۷۹۶ 0 ' ی  #! ۴۳ و م د ; < : ی98! ی#! *+, " ان ی" ت/ ر ل. د& ر/ ی/ ر 3 ی" ی" ق: یb نi ی: ی: ی: ره 0 ی/? ی 3 ۲۷۹۶ +* - د' #"! 6 آ (۱)4, 3 2 ا. -, & + ک& ) & ( % $ # ی ا 6 آ 4, / ) $ 2 & ) ر د آ ر د $ 2 ر د : 9-8 د > E < D 2 ا C د: B? > = A

More information

DE PUBLIC SERVICE COMPANY OF NEW HAMPSHIRE

DE PUBLIC SERVICE COMPANY OF NEW HAMPSHIRE DE 05-142 PUBLIC SERVICE COMPANY OF NEW HAMPSHIRE Petition for License to Construct and Maintain Electric Lines Over and Across the Public Waters of the Nashua River in the City of Nashua, New Hampshire

More information

Distribution System Line Models

Distribution System Line Models FAKULTA ELEKTROTECHNIKY A KOMUNIKAČNÍCH TECHNOLOGIÍ VYSOKÉ UČENÍ TECHNICKÉ V BRNĚ Distribution System Line Models Authors: Ing. Mayada Daboul doc. Ing. Jaroslava Orságová, Ph.D. May 2013 epower Inovace

More information

Tennessee Valley Authority. Thermal Assessment of Existing 161kv & 500kv Transmission Lines

Tennessee Valley Authority. Thermal Assessment of Existing 161kv & 500kv Transmission Lines Tennessee Valley Authority Thermal Assessment of Existing 161kv & 500kv Transmission Lines TVA Power Service Area Why are we gathering aerial laser survey & doing thermal assessments? Before 1977; NESC

More information

Modeling the structural dynamic response of overhead transmission lines

Modeling the structural dynamic response of overhead transmission lines Computers and Structures 81 (2003)825 834 www.elsevier.com/locate/compstruc Modeling the structural dynamic response of overhead transmission lines G. McClure *, M. Lapointe Department of Civil Engineering

More information

Chapter 8: Unsymmetrical Faults

Chapter 8: Unsymmetrical Faults Chapter 8: Unsymmetrical Faults Introduction The sequence circuits and the sequence networks developed in the previous chapter will now be used for finding out fault current during unsymmetrical faults.

More information

Experimental Study of the Artificial Neural Network Solutions for Insulators Leakage Current Modeling in a Power Network

Experimental Study of the Artificial Neural Network Solutions for Insulators Leakage Current Modeling in a Power Network Experimental Study of the Artificial Neural Network Solutions for Insulators Leakage Current Modeling in a Power Network Ali Bahramiazar Instrumentation Department, W.A. E.P.D Company, Orumieh, Iran Email:

More information

Electrical Distribution System Analysis Dr. Ganesh Kumbhar Department of Electrical Engineering Indian Institute of Technology, Roorkee

Electrical Distribution System Analysis Dr. Ganesh Kumbhar Department of Electrical Engineering Indian Institute of Technology, Roorkee Electrical Distribution System Analysis Dr. Ganesh Kumbhar Department of Electrical Engineering Indian Institute of Technology, Roorkee Lecture 10 Series Impedance of Distribution Lines and Feeders Part

More information

Magnetic Fields from Power Cables 1

Magnetic Fields from Power Cables 1 Power Electronics Notes 30H Magnetic Fields from Power Cables (Case Studies) Marc T. Thompson, Ph.D. Thompson Consulting, Inc. 9 Jacob Gates Road Harvard, MA 01451 Phone: (978) 456-7722 Fax: (240) 414-2655

More information

Power system conductor volume calculation

Power system conductor volume calculation Power system conductor volume calculation Dr Audih alfaoury T&D power systems 2017-1018 Electrical Energy Engineering Department Dr Audih alfaoury 1 The transmission of electric power is carried at high

More information

The WOLF system: forecasting wet-snow loads on power lines in Italy

The WOLF system: forecasting wet-snow loads on power lines in Italy Chongqing, China May 8-13, 2011 The WOLF system: forecasting wet-snow loads on power lines in Italy M. Lacavalla, P. Bonelli, G. Mariani, P. Marcacci, G. Stella Research on the Energy Systems - RSE S.p.A.

More information

This week. 3/23/2017 Physics 214 Summer

This week. 3/23/2017 Physics 214 Summer This week Electrical Circuits Series or parallel that s the question. Current, Power and Energy Why does my laptop battery die? Transmission of power to your home Why do we have big transmission towers?

More information

This week. 6/2/2015 Physics 214 Summer

This week. 6/2/2015 Physics 214 Summer This week Electrical Circuits Series or parallel that s the question. Current, Power and Energy Why does my laptop battery die? Transmission of power to your home Why do we have big transmission towers?

More information

Noon Sakinah and Tanween. Chapter 5

Noon Sakinah and Tanween. Chapter 5 Noon Sakinah and Tanween Chapter 5 Outline Definition of Noon Sakinah Definition of Tanween Al Idhar Al Idgham Al Qalb Al Ikhfa Definition of Noon Sakinah The ن does not have one of the three diacritical

More information

The Study of Overhead Line Fault Probability Model Based on Fuzzy Theory

The Study of Overhead Line Fault Probability Model Based on Fuzzy Theory Energy and Power Engineering, 2013, 5, 625-629 doi:10.4236/epe.2013.54b121 Published Online July 2013 (http://www.scirp.org/journal/epe) The Study of Overhead Line Fault Probability Model Based on Fuzzy

More information

Comparison of ice accumulation on simplex and duplex conductors in parallel overhead transmission lines in Iceland.

Comparison of ice accumulation on simplex and duplex conductors in parallel overhead transmission lines in Iceland. Comparison of ice accumulation on simplex and duplex conductors in parallel overhead transmission lines in Iceland. Árni Jón Elíasson 1, Árni Björn Jónasson 2 and Pétur Thor Gunnlaugsson 3 1 Landsnet,

More information

Design of AAC wall panel according to EN 12602

Design of AAC wall panel according to EN 12602 Design of wall panel according to EN 160 Example 3: Wall panel with wind load 1.1 Issue Design of a wall panel at an industrial building Materials with a compressive strength 3,5, density class 500, welded

More information

To order, specify : Types Protection functions Current surge Asymmetry and loss of phase. Operating principle

To order, specify : Types Protection functions Current surge Asymmetry and loss of phase. Operating principle otor protection relays - T - FWIT Since % of -phase motor failures are due to load problems or loss of phase, the CROUZET range of motor protection relays is indispensable! models give motor protection

More information

DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING QUESTION BANK

DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING QUESTION BANK DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING QUESTION BANK SUBJECT CODE & NAME: EE 2303 - TRANSMISSION & DISTRIBUTION YEAR / SEM: III/V UNIT-I TRANSMISSION SYSTEM INTRODUCTION PART-A 1. What is

More information

R&D of 22.9kV/50MVA HTS Transmission Power Cable in Korea

R&D of 22.9kV/50MVA HTS Transmission Power Cable in Korea Symposium on HTS Cable Application in Kunming R&D of 22.9kV/50MVA HTS Transmission Power Cable in Korea Jeonwook Cho Korea Electrotechnology Research Institute jwcho@keri.re.kr June 24, 2004 Order Introduce

More information

PHOENIX CONTACT - 04/2016. Features

PHOENIX CONTACT - 04/2016. Features Signal conditioner Data sheet 100238_de_06 1 Description PHOENIX CONTACT - 04/2016 Features The MCR-C-UI-UI(-450)-DCI(-NC) 3-way isolation amplifier is used to electrically isolate and convert analog signals.

More information

Update on the Developments of Coated Conductor High Field Magnets in Japan

Update on the Developments of Coated Conductor High Field Magnets in Japan Coated Conductors for Applications 2016 September 11-14, 2016, Aspen, Colorado, USA Update on the Developments of Coated Conductor High Field Magnets in Japan S. Awaji HFLSM, IMR, Tohoku University 1 Recent

More information

Analysis of the transients on the multi-circuit overhead transmission line

Analysis of the transients on the multi-circuit overhead transmission line Journal of ELECTRICAL ENGINEERING, VOL 68 (217), NO6, 476 481 Analysis of the transients on the multi-circuit overhead transmission line Tomáš Nazarčík, Zdeňka Benešová In this paper a method for a transient

More information

EX-EMERGENCY LIGHT FITTINGS

EX-EMERGENCY LIGHT FITTINGS EX-EMERGENCY LIGHT FITTINGS nllk 0...N 1-36 W Plastic version for Zone 2 and Zone 21/22 The explosion-protected light fittings of the series nllk 0 N are conform to the requirements of the ATEX-Directive

More information

Electrical, Electronic and Computer Engineering ENEL4HB - High Voltage 2

Electrical, Electronic and Computer Engineering ENEL4HB - High Voltage 2 Electrical, Electronic and Computer Engineering ENEL4HB - High oltage 2 Main Examination October 2016 Instructions Answer all questions, show all working and include all necessary comments (it is your

More information

MODELING OF THE DIRECT LIGHTNING STRIKE ON A TOWERS CASCADE EQUIPPED WITH ITS PROTECTIONS

MODELING OF THE DIRECT LIGHTNING STRIKE ON A TOWERS CASCADE EQUIPPED WITH ITS PROTECTIONS Progress In Electromagnetics Research M, Vol. 3, 53 69, 13 MODELING OF THE DIRECT LIGHTNING STRIKE ON A TOWERS CASCADE EQUIPPED WITH ITS PROTECTIONS Lotfi Boufenneche 1, Bachir Nekhoul 1, Kamal Kerroum,

More information

Homework # Physics 2 for Students of Mechanical Engineering. Part A

Homework # Physics 2 for Students of Mechanical Engineering. Part A Homework #9 203-1-1721 Physics 2 for Students of Mechanical Engineering Part A 5. A 25-kV electron gun in a TV tube fires an electron beam having a diameter of 0.22 mm at the screen. The spot on the screen

More information

Module 3 : Sequence Components and Fault Analysis

Module 3 : Sequence Components and Fault Analysis Module 3 : Sequence Components and Fault Analysis Lecture 13 : Sequence Modeling (Tutorial) Objectives In this lecture we will solve tutorial problems on fault analysis in sequence domain Per unit values

More information

Reduction of computational cost for design of wind turbine tower against fatigue failure

Reduction of computational cost for design of wind turbine tower against fatigue failure No. E-13-AAA- Reduction of computational cost for design of wind turbine tower against fatigue failure Ali R. Fathi, Hamid R. Lari, Abbas Elahi Wind turbine Technology Development Center Niroo Research

More information

Composite Conductor Field Trial Summary Report: Western Area Power Administration FARGO

Composite Conductor Field Trial Summary Report: Western Area Power Administration FARGO Composite Conductor Field Trial Summary Report: Western Area Power Administration FARGO Installation Date October, 2002 Field trial Location Fargo, North Dakota, USA Line Characteristics Utility: Western

More information

Chapter 15 Power And Harmonics in Nonsinusoidal Systems

Chapter 15 Power And Harmonics in Nonsinusoidal Systems Chapter 15 Power And Harmonics in Nonsinusoidal Systems 15.1. Average power in terms of Fourier series 15.2. RMS value of a waveform 15.3. Power factor THD Distortion and Displacement factors 15.4. Power

More information

Commissioning testing of a 1 MVA Superconducting transformer featuring 2G HTS Roebel cable

Commissioning testing of a 1 MVA Superconducting transformer featuring 2G HTS Roebel cable Commissioning testing of a 1 MVA Superconducting transformer featuring 2G HTS Roebel cable Glasson N, Staines M, Allpress N, Badcock R 10:45 2M-LS-O2 OUTLINE Introduction Electrical Design Specifications

More information

Power System Engineering Prof. Debrapriya Das Department of Electrical Engineering Indian Institute of Technology, Kharagpur

Power System Engineering Prof. Debrapriya Das Department of Electrical Engineering Indian Institute of Technology, Kharagpur Power System Engineering Prof. Debrapriya Das Department of Electrical Engineering Indian Institute of Technology, Kharagpur Lecture - 01 Overhead Line Insulators So, welcome to this another course that

More information

Induction_P1. 1. [1 mark]

Induction_P1. 1. [1 mark] Induction_P1 1. [1 mark] Two identical circular coils are placed one below the other so that their planes are both horizontal. The top coil is connected to a cell and a switch. The switch is closed and

More information

Physics 12 Final exam review key

Physics 12 Final exam review key Physics 12 Final exam review key 1) A scalar field differs from a vector field in that A. a scalar field acts in only one direction B. a vector field acts in only one direction C. direction is irrelevant

More information

Internal sc Coils for Dilution Refrigerators

Internal sc Coils for Dilution Refrigerators Internal sc Coils for Dilution Refrigerators Hartmut Dutz, Stefan Goertz, Ralf Heinz, Thomas Ludwig -1- Frozen-Spin-Target (Saclay/Bonn-type) P y P y P Z -2- limited angular acceptance ( low energy scattering

More information

Kinectrics North America Inc. Report No.: K RC-0001-R00 March 20, C.J. Pon, Z. Peter Transmission and Distribution Technologies Business

Kinectrics North America Inc. Report No.: K RC-0001-R00 March 20, C.J. Pon, Z. Peter Transmission and Distribution Technologies Business To: Colin McCullough 3M Company Bldg. 21-2-A-39 St. Paul, MN 144-1 USA KINECTRICS NORTH AMERICA INC. REPORT FOR 3M COMPANY TO TEST SHORT CIRCUIT BEHAVIOUR OF 79-T16 ACCR IN A TWO-CONDUCTOR BUNDLE CONFIGURATION

More information

EFFECT OF CLIMATIC VARIATIONS ON POLLUTION DEPOSIT ON ELECTRIC INSULATION AND RELATED FAILURE

EFFECT OF CLIMATIC VARIATIONS ON POLLUTION DEPOSIT ON ELECTRIC INSULATION AND RELATED FAILURE EFFECT OF CLIMATIC VARIATIONS ON POLLUTION DEPOSIT ON ELECTRIC INSULATION AND RELATED FAILURE M.REZAEI M.A.SHARIATI M.A.TALEBI F.DANESHVAR N.R.I -Iran N.R.I -Iran N.R.I -Iran H.D.E.C-Iran Marezaei@nri.ac.ir

More information

ICS Supersedes EN : A1:2009, EN :2005. English version

ICS Supersedes EN : A1:2009, EN :2005. English version EUROPEAN STANDARD EN 50341-1 NORME EUROPÉENNE EUROPÄISCHE NORM December 2012 ICS 29.240.20 Supersedes EN 50341-1:2001 + A1:2009, EN 50423-1:2005 English version Overhead electrical lines exceeding AC 1

More information

Experimental analyses for the determination of lifetime expectancy of transmission line conductors

Experimental analyses for the determination of lifetime expectancy of transmission line conductors Experimental Vibration Analysis for Civil Engineering Structures 1197 Experimental analyses for the determination of lifetime expectancy of transmission line conductors A.L. Rolim, L. A. C. M. Veloso,

More information

In the previous chapter, attention was confined

In the previous chapter, attention was confined 4 4 Principles of Power System CHAPTE CHAPTE 8 Unsymmetrical Fault Calculations 8. Usymmetrical Faults on -Phase System 8. Symmetrical Components Method 8. Operator a 8.4 Symmetrical Components in Terms

More information

Calculations of Capacitance for Transposed Bundled Conductor Transmission Lines

Calculations of Capacitance for Transposed Bundled Conductor Transmission Lines Calculations of Capacitance for Transposed Bundled Conductor Transmission Lines Multi-conductor Lines. An example with a conductor bundle r: conductor radius, d: distance between conductors of the same

More information

CALCULATION OF POWER FREQUENCY FIELDS FROM HIGH VOLTAGE OVERHEAD LINES IN RESIDENTIAL AREAS

CALCULATION OF POWER FREQUENCY FIELDS FROM HIGH VOLTAGE OVERHEAD LINES IN RESIDENTIAL AREAS CALCULATION OF POWER FREQUENCY FIELDS FROM HIGH VOLTAGE OVERHEAD LINES IN RESIDENTIAL AREAS I. N. Ztoupis *, I. F. Gonos and I. A. Stathopulos National Technical University of Athens, School of Electrical

More information

Fatima Michael College of Engineering & Technology

Fatima Michael College of Engineering & Technology ANNA UNIVERSITY AFFILIATED COLLEGES BE EEE SEMESTER VI EE2353 - HIGH VOLTAGE ENGINEERING UNIT IOVER VOLTAGES IN ELECTRICAL POWER SYSTEMS 1. What is surge arrester? 2. Name the sources of switching surges.

More information

Thermal-Magnetic Circuit Breaker 2210-T2...

Thermal-Magnetic Circuit Breaker 2210-T2... Thermal-Magnetic Circuit Breaker 0-T... Description One, two and three pole thermal-magnetic circuit breakers with trip-free mechanism and toggle actuation (S-type TM CBE to EN 6094/IEC 94). Featuring

More information

Qualification Test Report. Modular Plugs, Unshielded and Shielded

Qualification Test Report. Modular Plugs, Unshielded and Shielded Qualification Test Report 501-131013 26 JAN 16 Rev. A Modular Plugs, Unshielded and Shielded 1. INTRODUCTION 1.1. Purpose Testing was performed on modular plugs to determine their conformance to the requirements

More information

SPECIFICATION CUSTOMER : SHEET NO. DATE MODEL NAME DR2-102K-B & T DR 6.5X7.5mm PART NAME. Radial Inductor PART NO.

SPECIFICATION CUSTOMER : SHEET NO. DATE MODEL NAME DR2-102K-B & T DR 6.5X7.5mm PART NAME. Radial Inductor PART NO. PART NAME Radial Inductor PART NO. DR)mH(0K) SHEET NO. DATE MODEL NAME DESCRIPTION OF 0 06-09-0 DR-0K-B & T DR 6.5X7.5mm. GENERAL ) SCOPE This specfication applies to part number mh PEAKING COIL for use

More information

Vegetation Related Transmission Outage Report

Vegetation Related Transmission Outage Report Vegetation Related Transmission Outage Report Third 2013 3353 Peachtree Road NE Suite 600, North Tower Atlanta, GA 30326 404-446-2560 www.nerc.com Executive Summary The NERC Board of Trustees Compliance

More information

two loads, forces and vectors ELEMENTS OF ARCHITECTURAL STRUCTURES: FORM, BEHAVIOR, AND DESIGN DR. ANNE NICHOLS SPRING 2017 lecture ARCH 614

two loads, forces and vectors ELEMENTS OF ARCHITECTURAL STRUCTURES: FORM, BEHAVIOR, AND DESIGN DR. ANNE NICHOLS SPRING 2017 lecture ARCH 614 ELEMENTS OF ARCHITECTURAL STRUCTURES: FORM, BEHAVIOR, AND DESIGN DR. ANNE NICHOLS SPRING 2017 lecture two y x z loads, forces and vectors Forces 1 Structural Design planning preliminary structural configuration

More information

Transmission and Distribution of Electrical Power

Transmission and Distribution of Electrical Power KINGDOM OF SAUDI ARABIA Ministry Of High Education Umm Al-Qura University College of Engineering & Islamic Architecture Department Of Electrical Engineering Transmission and Distribution of Electrical

More information

PUB NLH 185 Island Interconnected System Supply Issues and Power Outages Page 1 of 9

PUB NLH 185 Island Interconnected System Supply Issues and Power Outages Page 1 of 9 PUB NLH 1 Page 1 of 1 Q. Provide Hydro s list of outage cause codes and indicate how troublemen are managed and trained to properly use the codes. Explain the method used to report outage causes. A. Hydro

More information

Lightning Insulation Coordination Study

Lightning Insulation Coordination Study Lightning Insulation Coordination Study Presenter: Nguyen Dong Hai Le Pacific 1 Presentation Outline Introduction Network Components Model Stroke Current Model Case Studies and esults Conclusions 1 Introduction

More information

+.x2yaz V/m and B = y 2 ax + z2a 1. + x2az Wb/m 2. Find the force on the charge at P.

+.x2yaz V/m and B = y 2 ax + z2a 1. + x2az Wb/m 2. Find the force on the charge at P. 396 CHAPTER 8 MAGNETC FORCES, MATERALS, AND DEVCES Section 8.2-Forces Due to Magnetic Fields 8.1 A 4 mc charge has velocity u = l.4ax - 3.2ay - az mis at point P(2, 5, - 3) in the presence of E = 2xyzax

More information

Vegetation Related Transmission Outage Report

Vegetation Related Transmission Outage Report Vegetation Related Transmission Outage Report Third Quarter 0 5 Peachtree Road NE Suite 00, North Tower Atlanta, GA 0 404-44-50 www.nerc.com The NERC Board of Trustees Compliance Committee has reviewed

More information

POE Practice Test - Electricity, Power, & Energy

POE Practice Test - Electricity, Power, & Energy Class: Date: POE Practice Test - Electricity, Power, & Energy Multiple Choice Identify the choice that best completes the statement or answers the question. 1. Which of the following forms of energy is

More information

I nllk 08018/18 I nllk I nllk 08036/36 I nllk I I nllk 08058/58 I

I nllk 08018/18 I nllk I nllk 08036/36 I nllk I I nllk 08058/58 I I nllk / I x W x W x W x W x W Technical data Cooper Crouse-Hinds - all rights reserved nllk / nllk nllk / nllk nllk / Marking to //EC II G Ex na II T / II D td A IP T C EC Conformity Statement PTB ATEX

More information

LD-LP-LL-LC Rope Safety Switches with reset for emergency stop

LD-LP-LL-LC Rope Safety Switches with reset for emergency stop TECHNICA DATASHEET D-P--C Rope Safety Switches with reset for emergency stop Metal or polymer housing, from one or three conduit entries Protection degree IP6 In conformity with EN ISO 13850 contact blocks

More information

Fatigue of stay cables inside end fittings high frequencies of wind induced vibrations

Fatigue of stay cables inside end fittings high frequencies of wind induced vibrations D. Siegert, P. Brevet Laboratoire Central des Ponts et Chaussées, France Fatigue of stay cables inside end fittings high frequencies of wind induced vibrations Summary A twenty year old stay cable was

More information

Experience in manufacturing a large HTS magnet for a SMES

Experience in manufacturing a large HTS magnet for a SMES Superconducting magnets April 05-09, 2009 CEA Cadarache, France Experience in manufacturing a large HTS magnet for a SMES P. Tixador Grenoble INP / Institut Néel - G2Elab Outline Introduction: SMES SMES:

More information

EECE421 Power System Analysis. Chapter 4: Transmission Line Capacitance

EECE421 Power System Analysis. Chapter 4: Transmission Line Capacitance EECE421 Power System Analysis Chapter 4: Transmission Line Capacitance 1 Capacitance C: Capacitance Caused by the potential difference between the conductors (Charge) per (unit of potential difference)

More information

National Exams May 2016

National Exams May 2016 National Exams May 2016 04-Agric-A5, Principles of Instrumentation 3 hours duration NOTES: 1. If doubt exists as to the interpretation of any question, the candidate is urged to submit with the answer

More information

Universal limit switches

Universal limit switches SWITCHES.CROUZET.COM 1 LIMIT SWITCHES 0/016 Universal limit switches 8384 standard 8384 with positive break operation Conformity to standards IEC / EN 60947--1, including Annex K for version with positive

More information

Aalborg Universitet. Published in: Cigré International colloquium on lightning and power systems, Lyon Publication date: 2014

Aalborg Universitet. Published in: Cigré International colloquium on lightning and power systems, Lyon Publication date: 2014 Aalborg Universitet Comparison of overhead line lightning performance based on two different tower geometries Ebdrup, Thomas; Olason, Daniel ; Bak, Claus Leth; Silva, Filipe Miguel Faria da Published in:

More information

ENGN1300: Structural Analysis. Homework 5 Due Wednesday March 12, 2010

ENGN1300: Structural Analysis. Homework 5 Due Wednesday March 12, 2010 ENGN1300: Structural Analsis Homework 5 Due Wednesda March 12, 2010 Division of Engineering Brown Universit 1. Using the solutions derived in class for a cable hanging under its own weight, find the cable

More information

Collapse types and robustness measures

Collapse types and robustness measures Collapse types and robustness measures Uwe Starossek 1/30 Disproportionate collapse is characterized by a distinct disproportion between cause and effect, i.e., between the triggering event and the resulting

More information

Rodless cylinders Series 1600

Rodless cylinders Series 1600 Rodless cylinders Series 00 Basic version 0.Ø.stroke.0.M Max. stroke mt.) AL AI RA RB AF TC AM L LA+stroke AH TD AE TA RV Possibility of a single feed cylinder head AI AP AB AC AD TD TE TB AG RT Left head

More information

JOINT U.S.-CANADA POWER SYSTEM OUTAGE TASK FORCE

JOINT U.S.-CANADA POWER SYSTEM OUTAGE TASK FORCE JOINT U.S.-CANADA POWER SYSTEM OUTAGE TASK FORCE INITIAL REPORT Phone: 415.897.8883 Email: rnovembri@cnutility.com FERC Contract: FERC-03AL-30574 BACKGROUND CN Utility Consulting, (an industry firm specializing

More information

Twenty Years of Ice Monitoring Experience On Overhead Lines In Newfoundland and Labrador

Twenty Years of Ice Monitoring Experience On Overhead Lines In Newfoundland and Labrador Twenty Years of Ice Monitoring Experience On Overhead Lines In Newfoundland and Labrador Asim Haldar Specialist Engineer Transmission and Distribution Department Engineering Services Newfoundland and Labrador

More information

Civil & Structural Engineering Design Services Pty. Ltd.

Civil & Structural Engineering Design Services Pty. Ltd. Client: EXTREME MARQUEES PTY. LTD. Project: Design check 24.4m x 12.2m x 6.4m The Platoon Tent Structure (3m Bay) for 80km/hr Wind Speed. Reference: Extreme Marquees Pty Ltd Technical Data Report by: KZ

More information

51U MULTI POWER METER MODEL. Panel Mounted Multi Power Meter 51-UNIT

51U MULTI POWER METER MODEL. Panel Mounted Multi Power Meter 51-UNIT Panel Mounted Multi Power Meter 5-UI MULI POWE MEE MODEL 5U MODEL & UFFIX CODE ELECIO 5U MODEL IPU (balanced load) * 0 : ingle-phase / -wire, 05 / 5 C (P. 5/6) * : ingle-phase / 3-wire, 05 / 0 / 5 C (P.

More information

LO 1: Three Phase Circuits

LO 1: Three Phase Circuits Course: EEL 2043 Principles of Electric Machines Class Instructor: Dr. Haris M. Khalid Email: hkhalid@hct.ac.ae Webpage: www.harismkhalid.com LO 1: Three Phase Circuits Three Phase AC System Three phase

More information

Type UB1 Load Cell. Option Stainless steel cable gland

Type UB1 Load Cell. Option Stainless steel cable gland Type UB1 Load Cell IP68 APPROVED Product Description Type UB1 is a stainless steel universal load cell which allows for tension and compression loading. Its complete hermetic sealing makes it suitable

More information

Electromagnetic Field Interaction with

Electromagnetic Field Interaction with Electromagnetic Field Interaction with Transmission Lines From classical theory to HF radiation effects Edited by F Rachidi sc S Tkachenko WITPRESS Southampton, Boston Contents Preface xv PART I: CLASSICAL

More information

Physics Tutorial MF1 Magnetic Forces

Physics Tutorial MF1 Magnetic Forces Physics Tutorial MF1 Magnetic Forces 1 Magnetic Forces The force F on a charge q moving with velocity v in a magnetic field is: F = qv The force F on a straight conductor of length L carrying a current

More information

Estimation of the characteristic of contact line uplift and strain in the neighborhood of a tunnel inlet by computer simulation

Estimation of the characteristic of contact line uplift and strain in the neighborhood of a tunnel inlet by computer simulation Computers in Railways XIII 147 Estimation of the characteristic of contact line uplift and strain in the neighborhood of a tunnel inlet by computer simulation Y. Sugama1, K. Shimizu1 & S. Amari 1 Railway

More information