Steven Tilley Fully 3D Recon 2015 May 31 -June 4

Size: px
Start display at page:

Download "Steven Tilley Fully 3D Recon 2015 May 31 -June 4"

Transcription

1 Fully3D Advanced System Models for Reconstruction in Flat-Panel Detector Cone-Beam CT Steven Tilley, Jeffrey Siewerdsen, Web Stayman Johns Hopkins University Schools of Medicine and Engineering Acknowledgements AIAI Laboratory Advanced Imaging Algorithms and Instrumentation Lab aiai.jhu.edu I-STAR Laboratory Imaging for Surgery, Therapy, and Radiology istar.jhu.edu Faculty and Scientists Tharindu De Silva Grace Gang Aswin Mathews Amir Pourmorteza Jeffrey Siewerdsen Alejandro Sisniega Shiyu Xu Wojciech Zbijewski Students Qian Cao Hao Dang Sarah Ouadah Sureerat Reaungamornrat Steven Tilley II Ali Uneri Jennifer Xu Thomas Yi Industry Partners Sungwon Yoon Kevin Holt David Nisius Edward Shapiro Funding Supported in part by a Varian industry partnership and NIH grants R21-EB and T32-EB This work was supported, in part, by the above grants. The contents of this presentation are solely the responsibility of the authors and do not necessarily represent the official view of Johns Hopkins or the NIH. Johns Hopkins University 1

2 Noise model and reality mismatch Normalized Detector Units Normalized Detector Units Source and Detector Blur Modeling Mean: g y 0 = B s D g exp( Aμ) y = B d B s D g exp( Aμ) Source Blur B s Extended X-ray Source B s Light Photons B d Detector Blur B d X-ray Photons Photodiodes Object Scintillator Covariance: D{g} D{ y 0 } B d D y 0 B d T B d D y 0 B d T + K ro Quanta: Uncorrelated Bare Beam Uncorrelated, Attenuated X-rays with Focal Spot Blur Correlated Light Photons with Light Spread Correlated Electrons with Readout Noise Forward Model: Noise Model: y(μ) = B d B s D g exp( Aμ) y~gaussian( y, K y ) K Y = B d D y 0 B d T + K ro Johns Hopkins University 2

3 Simple estimate from forward model: l = log D 1 g B 1 y B = B d B s Linearization Estimated Covariance of l 1 K L D B 1 y B 1 K Y B 1 T D 1 B 1 y Blurs may have nullspaces/regions of poor invertiblilty. B 1 C 1 = masked deblur C C 1 1 = masked blur K 1 L D C 1 y C B d D C 1 y B T d + K2 σro 1 C T D C 1 y Objective Function Φ μ = ψ μ L = l) + βp(μ) Likelihood Term Penalty Term Where l is an estimate of the line integrals and µ is the attenuation values If the line integrals are from a Gaussian distribution: ψ μ L = l) = Aμ l KL = Aμ l T K L 1 Aμ l : weighted least squares If P μ = μ T Rμ (quadratic) then: μ = A T K L 1 A βr 1 A T K L 1 l Johns Hopkins University 3

4 Solving Strategy μ = A T K L 1 A βr 1 A T K L 1 l Preprocessing: l = [ log D 1 g C 1 y ] b = A T K 1 L l Solve using CG A T K 1 L A + βr μ = b Evalulate K L 1 x: p = C T D C 1 y x solve for q using CG where: K Y q = p b = D C 1 y C q return b K L 1 D C 1 y C T K Y 1 C D C 1 y Simulation Phantom Metrics: Resolution edge response of disk Variance spatial variance center of disk in Comparisons are made to an uncorrelated noise model: 1 K L = C 1 2 y + σ ro Phantom: 4000x x25 µm voxels projected onto x35 µm pixels Reconstruction: 1000x x100 µm voxels with x140 µm pixels Geometry: SAD = 600, SDD = 1200, 720 angles, full rotation Johns Hopkins University 4

5 Simulation Phantom Reconstructions Varying Blur Distribution 2 FWHM Total = FWHM s 2 + FWHM d 2 = Constant Assess effects of varying different types of blur when total blur is constant Johns Hopkins University 5

6 Varying Total Blur FWHM s FWHM d = Constant Assess effects of varying total blur when the ratio of blur widths is constant Test Bench Studies Volume: 210x600x600 Voxels: 150 µm 720 Projections Full orbit SDD: 1180 mm SAD: 600 mm Pixels: 388x388 µm 100 kvp 0.63 mas per projection Johns Hopkins University 6

7 Detector MTF Measurements E. Samei, M. J. Flynn, and D. a. Reimann, A method for measuring the presampled MTF of digital radiographic systems using an edge test device, Med. Phys., vol. 25, no. 1, p. 102, Source MTF Johns Hopkins University 7

8 Bench Data Reconstruction Bench Data Reconstruction Difference from high resolution reference Johns Hopkins University 8

9 Conclusion - More accurate noise models improve model based algorithms. - Modeling noise correlations are important in the presence of large source blurs. - Clinical systems with specs similar to our test bench will be able to better resolve fine structure such as trabeculae using this method Future directions - Model higher order characteristics of source blur - Nonlinear objective function Source Pinhole image Johns Hopkins University 9

7/30/2018. CT Hardware Basics. X-ray Tube Physics and Dose Reduction

7/30/2018. CT Hardware Basics. X-ray Tube Physics and Dose Reduction J. Webster Stayman Advanced Imaging Algorithms and Instrumentation Lab (aiai.jhu.edu) Johns Hopkins University August 30, 018 CT Hardware Basics X-ray Tube Detector (image Credit) https://www.youtube.com/watch?v=bg0inhwarw

More information

The Generalized NEQ and Detectability Index for Tomosynthesis and Cone-Beam CT

The Generalized NEQ and Detectability Index for Tomosynthesis and Cone-Beam CT The Generalized NEQ and Detectability Inde for Tomosynthesis and Cone-Beam CT Grace J. Gang 1, Junghoon Lee 2, J. Webster Stayman 3, Daniel Tward 3,W. Zbijewski 3, Jerry L. Prince 2, and Jeffrey H. Siewerdsen

More information

Analysis of Image Noise in 3D Cone-Beam CT: Spatial and Fourier Domain Approaches under Conditions of Varying Stationarity

Analysis of Image Noise in 3D Cone-Beam CT: Spatial and Fourier Domain Approaches under Conditions of Varying Stationarity Analysis of Image Noise in 3D Cone-Beam CT: Spatial and Fourier Domain Approaches under Conditions of Varying Stationarity Angel R. Pineda *a, Jeffrey H. Siewerdsen b,c, Daniel J. Tward b a Department

More information

Scan Time Optimization for Post-injection PET Scans

Scan Time Optimization for Post-injection PET Scans Presented at 998 IEEE Nuc. Sci. Symp. Med. Im. Conf. Scan Time Optimization for Post-injection PET Scans Hakan Erdoğan Jeffrey A. Fessler 445 EECS Bldg., University of Michigan, Ann Arbor, MI 4809-222

More information

Development of a Monte Carlo Simulation Code and Its Test Results for Optimal Design of a Digital Radiographic System Based on a CMOS Image Sensor

Development of a Monte Carlo Simulation Code and Its Test Results for Optimal Design of a Digital Radiographic System Based on a CMOS Image Sensor Journal of the Korean Physical Society, Vol. 46, No. 2, February 2005, pp. 418 424 Development of a Monte Carlo Simulation Code and Its Test Results for Optimal Design of a Digital Radiographic System

More information

Generalized DQE analysis of radiographic and dual-energy imaging using flat-panel detectors

Generalized DQE analysis of radiographic and dual-energy imaging using flat-panel detectors Generalized DQE analysis of radiographic and dual-energy imaging using flat-panel detectors S. Richard Department of Medical Biophysics, University of Toronto, Ontario, Canada M5G M9 J. H. Siewerdsen a

More information

The relationship between image noise and spatial resolution of CT scanners

The relationship between image noise and spatial resolution of CT scanners The relationship between image noise and spatial resolution of CT scanners Sue Edyvean, Nicholas Keat, Maria Lewis, Julia Barrett, Salem Sassi, David Platten ImPACT*, St George s Hospital, London *An MDA

More information

Maximum-Likelihood Deconvolution in the Spatial and Spatial-Energy Domain for Events With Any Number of Interactions

Maximum-Likelihood Deconvolution in the Spatial and Spatial-Energy Domain for Events With Any Number of Interactions IEEE TRANSACTIONS ON NUCLEAR SCIENCE, VOL. 59, NO. 2, APRIL 2012 469 Maximum-Likelihood Deconvolution in the Spatial and Spatial-Energy Domain for Events With Any Number of Interactions Weiyi Wang, Member,

More information

and the Existence of True Models

and the Existence of True Models Statistical Image Reconstruction and the Existence of True Models Joseph A. O Sullivan Samuel C. Sachs Professor Dean, UMSL/WU Joint Undergraduate Engineering Program Professor of Electrical and Systems

More information

Neural Network Approach for Photon-counting Detection The First Step: PPE Correction

Neural Network Approach for Photon-counting Detection The First Step: PPE Correction Neural Network Approach for Photon-counting Detection The First Step: PPE Correction Ruibin Feng, Ph.D. Biomedical Imaging Center, CBIS/BME, RPI fengr@rpi.edu David Rundle JairiNovus Technologies Ltd.

More information

Iterative Data Refinement for Soft X-ray Microscopy

Iterative Data Refinement for Soft X-ray Microscopy Iterative Data Refinement for Soft X-ray Microscopy Presented by Joanna Klukowska August 2, 2013 Outline Iterative Data Refinement Transmission X-ray Microscopy Numerical Tests Joanna Klukowska IDR for

More information

Multi-energy CT: Future Directions. Acknowledgements. Overview 7/23/2014. Taly Gilat Schmidt, PhD. Kevin Zimmerman Franco Rupcich Steven Haworth

Multi-energy CT: Future Directions. Acknowledgements. Overview 7/23/2014. Taly Gilat Schmidt, PhD. Kevin Zimmerman Franco Rupcich Steven Haworth Multi-energy CT: Future Directions Taly Gilat Schmidt, PhD Department of Biomedical Engineering Marquette University Acknowledgements Kevin Zimmerman Franco Rupcich Steven Haworth Results in this talk:

More information

Recent advances and future perspectives of gamma imagers for scintimammography

Recent advances and future perspectives of gamma imagers for scintimammography 3rd International Conference on Imaging Technologies in Biomedical Sciences: ITBS2005 Innovation in Nuclear and Radiological Imaging: From Basic Research to Clinical Application Milos Conference Center,

More information

Ke Li and Guang-Hong Chen

Ke Li and Guang-Hong Chen Ke Li and Guang-Hong Chen Brief introduction of x-ray differential phase contrast (DPC) imaging Intrinsic noise relationship between DPC imaging and absorption imaging Task-based model observer studies

More information

AQA Physics /7408

AQA Physics /7408 AQA Physics - 7407/7408 Module 10: Medical physics You should be able to demonstrate and show your understanding of: 10.1 Physics of the eye 10.1.1 Physics of vision The eye as an optical refracting system,

More information

Initial Studies in Proton Computed Tomography

Initial Studies in Proton Computed Tomography SCIPP Initial Studies in Proton Computed Tomography L. R. Johnson, B. Keeney, G. Ross, H. F.-W. Sadrozinski, A. Seiden, D.C. Williams, L. Zhang Santa Cruz Institute for Particle Physics, UC Santa Cruz,

More information

Biomedical Engineering Image Formation

Biomedical Engineering Image Formation Biomedical Engineering Image Formation PD Dr. Frank G. Zöllner Computer Assisted Clinical Medicine Medical Faculty Mannheim Learning objectives! Understanding the process of image formation! Point spread

More information

Towards Proton Computed Tomography

Towards Proton Computed Tomography SCIPP Towards Proton Computed Tomography L. R. Johnson, B. Keeney, G. Ross, H. F.-W. Sadrozinski, A. Seiden, D.C. Williams, L. Zhang Santa Cruz Institute for Particle Physics, UC Santa Cruz, CA 95064 V.

More information

A dual scintillator - dual silicon photodiode detector module for intraoperative gamma\beta probe and portable anti-compton spectrometer

A dual scintillator - dual silicon photodiode detector module for intraoperative gamma\beta probe and portable anti-compton spectrometer University of Wollongong Research Online Faculty of Engineering - Papers (Archive) Faculty of Engineering and Information Sciences 2008 A dual scintillator - dual silicon photodiode detector module for

More information

X-ray polarimetry and new prospects in high-energy astrophysics

X-ray polarimetry and new prospects in high-energy astrophysics X-ray polarimetry and new prospects in high-energy astrophysics Carmelo Sgrò INFN Pisa carmelo.sgro@pi.infn.it Frascati, March 31, 2016 A new exploration window: X-Ray polarimetry Spectroscopy, imaging

More information

A FISTA-like scheme to accelerate GISTA?

A FISTA-like scheme to accelerate GISTA? A FISTA-like scheme to accelerate GISTA? C. Cloquet 1, I. Loris 2, C. Verhoeven 2 and M. Defrise 1 1 Dept. of Nuclear Medicine, Vrije Universiteit Brussel 2 Dept. of Mathematics, Université Libre de Bruxelles

More information

Combined neutron and X-ray imaging on different length scales

Combined neutron and X-ray imaging on different length scales More Info at Open Access Database www.ndt.net/?id=18740 Combined neutron and X-ray imaging on different length scales Anders Kaestner, David Mannes, Jan Hovind, Pierre Boillat, and Eberhard Lehmann Neutron

More information

Maximal Entropy for Reconstruction of Back Projection Images

Maximal Entropy for Reconstruction of Back Projection Images Maximal Entropy for Reconstruction of Back Projection Images Tryphon Georgiou Department of Electrical and Computer Engineering University of Minnesota Minneapolis, MN 5545 Peter J Olver Department of

More information

Outline. Indrin J. Chetty, AAPM 2006 Monte Carlo CE course. Indrin J. Chetty Henry Ford Hospital. David W. O. Rogers Carleton University

Outline. Indrin J. Chetty, AAPM 2006 Monte Carlo CE course. Indrin J. Chetty Henry Ford Hospital. David W. O. Rogers Carleton University AAPM Task Group Report No. 105: Issues associated with clinical implementation of Monte Carlo-based photon and electron external beam treatment planning Indrin J. Chetty Henry Ford Hospital David W. O.

More information

Two-Material Decomposition From a Single CT Scan Using Statistical Image Reconstruction

Two-Material Decomposition From a Single CT Scan Using Statistical Image Reconstruction / 5 Two-Material Decomposition From a Single CT Scan Using Statistical Image Reconstruction Yong Long and Jeffrey A. Fessler EECS Department James M. Balter Radiation Oncology Department The University

More information

Noise Analysis of Regularized EM for SPECT Reconstruction 1

Noise Analysis of Regularized EM for SPECT Reconstruction 1 Noise Analysis of Regularized EM for SPECT Reconstruction Wenli Wang and Gene Gindi Departments of Electrical Engineering and Radiology SUNY at Stony Brook, Stony Brook, NY 794-846 Abstract The ability

More information

Factors affecting Probability of Detection with Computed Radiography

Factors affecting Probability of Detection with Computed Radiography 17th World Conference on Nondestructive Testing, 5-8 Oct 008, Shanghai, China Factors affecting Probability of Detection with Computed Radiography Gregory A. MOHR 1 and Peter WILLEMS 1 GE Inspection Technologies

More information

Using Prompt gamma ray emission to address uncertainties in proton therapy

Using Prompt gamma ray emission to address uncertainties in proton therapy Using Prompt gamma ray emission to address uncertainties in proton therapy Jerimy C. Polf, PhD, DABR Department of Radia9on Oncology University of Maryland School of Medicine AAPM 2013 Disclosures and

More information

Technical University of Denmark

Technical University of Denmark Technical University of Denmark Page 1 of 10 pages Written test, 12 December 2012 Course name: Introduction to medical imaging Course no. 31540 Aids allowed: None. Pocket calculator not allowed "Weighting":

More information

Medical Physics. Image Quality 1) Ho Kyung Kim. Pusan National University

Medical Physics. Image Quality 1) Ho Kyung Kim. Pusan National University Medical Physics Prince & Links 3 Image Quality 1) Ho Kyung Kim hokyung@pusan.ac.kr Pusan National University 1) The degree to which an image allows medical professionals to accomplish their goals (e.g.,

More information

Detecting high energy photons. Interactions of photons with matter Properties of detectors (with examples)

Detecting high energy photons. Interactions of photons with matter Properties of detectors (with examples) Detecting high energy photons Interactions of photons with matter Properties of detectors (with examples) Interactions of high energy photons with matter Cross section/attenution length/optical depth Photoelectric

More information

What is Albira and How Does the System Work and Why is it Differentiated Technology? Page 1

What is Albira and How Does the System Work and Why is it Differentiated Technology? Page 1 What is Albira and How Does the System Work and Why is it Differentiated Technology? Page 1 Why Albira? Tri-modality: PET, SPECT, CT Modular and state-of-the-art electronics 6 configurations Novel, Proprietary

More information

Universität Potsdam Institut für Informatik Lehrstuhl Maschinelles Lernen PCA. Tobias Scheffer

Universität Potsdam Institut für Informatik Lehrstuhl Maschinelles Lernen PCA. Tobias Scheffer Universität Potsdam Institut für Informatik Lehrstuhl Maschinelles Lernen PCA Tobias Scheffer Overview Principal Component Analysis (PCA) Kernel-PCA Fisher Linear Discriminant Analysis t-sne 2 PCA: Motivation

More information

X-ray Intensity Fluctuation Spectroscopy. Mark Sutton McGill University

X-ray Intensity Fluctuation Spectroscopy. Mark Sutton McGill University X-ray Intensity Fluctuation Spectroscopy Mark Sutton McGill University McGill University Collaborators J-F. Pelletier K. Laaziri K. Hassani A. Fluerasu E. Dufresne G. Brown M. Grant Yale/MIT S. Mochrie

More information

Reconstruction for Proton Computed Tomography: A Monte Carlo Study

Reconstruction for Proton Computed Tomography: A Monte Carlo Study Reconstruction for Proton Computed Tomography: A Monte Carlo Study T Li, Z. Liang, K. Mueller, J. Heimann, L. Johnson, H. Sadrozinski, A. Seiden, D. Williams, L. Zhang, S. Peggs, T. Satogata, V. Bashkirov,

More information

size within a local area. Using the image as a matched lter, a nite number of scales are searched within a local window to nd the wavelet coecients th

size within a local area. Using the image as a matched lter, a nite number of scales are searched within a local window to nd the wavelet coecients th In Proceeding of the 3rd International Workshop on Digital Mammography Chicago, U.S.A. 1996, pp. 447-450 Segmentation of Masses Using Continuous Scale Representations Andrew Laine a, Walter Huda b, Dongwei

More information

ESTIMATION OF 90 SCATTERING COEFFICIENT IN THE SHIELDING CALCULATION OF DIAGNOSTIC X-RAY EQUIPMENT

ESTIMATION OF 90 SCATTERING COEFFICIENT IN THE SHIELDING CALCULATION OF DIAGNOSTIC X-RAY EQUIPMENT Proceedings of the Eleventh EGS4 Users' Meeting in Japan, KEK Proceedings 2003-15, p.107-113 ESTIMATION OF 90 SCATTERING COEFFICIENT IN THE SHIELDING CALCULATION OF DIAGNOSTIC X-RAY EQUIPMENT K. Noto and

More information

Applied Radiation and Isotopes

Applied Radiation and Isotopes Applied Radiation and Isotopes 69 () 6 67 Contents lists available at ScienceDirect Applied Radiation and Isotopes journal homepage: www.elsevier.com/locate/apradiso Evaluation of dual g-ray imager with

More information

Computer Vision & Digital Image Processing

Computer Vision & Digital Image Processing Computer Vision & Digital Image Processing Image Restoration and Reconstruction I Dr. D. J. Jackson Lecture 11-1 Image restoration Restoration is an objective process that attempts to recover an image

More information

Recent Advances of Planar Silicon APD Technology

Recent Advances of Planar Silicon APD Technology Recent Advances of Planar Silicon APD Technology M. McClish 1, R. Farrell 1, R. Myers 1, F. Olschner 2, G. Entine 1, K.S. Shah 1 1 Radiation Monitoring Devices Inc., Watertown, MA 2 Cremat Inc., Newton,

More information

Bayesian approach to image reconstruction in photoacoustic tomography

Bayesian approach to image reconstruction in photoacoustic tomography Bayesian approach to image reconstruction in photoacoustic tomography Jenni Tick a, Aki Pulkkinen a, and Tanja Tarvainen a,b a Department of Applied Physics, University of Eastern Finland, P.O. Box 167,

More information

Fast and compact proton radiography imaging system for proton radiotherapy

Fast and compact proton radiography imaging system for proton radiotherapy Fast and compact proton radiography imaging system for proton radiotherapy Aleksandra K. Biegun ATTRACT NL Kick-off event, 9 th February 2017, Amsterdam, The Netherlands Proton therapy work flow CT scan

More information

Henry Ford NERS/BIOE 481. Lecture 05 Radiographic Image Formation

Henry Ford NERS/BIOE 481. Lecture 05 Radiographic Image Formation NERS/BIOE 481 Lecture 05 Radiographic Image Formation Michael Flynn, Adjunct Prof Nuclear Engr & Rad. Science mikef@umich.edu mikef@rad.hfh.edu Henry Ford Health System RADIOLOGY RESEARCH IV - General

More information

Detection of X-Rays. Solid state detectors Proportional counters Microcalorimeters Detector characteristics

Detection of X-Rays. Solid state detectors Proportional counters Microcalorimeters Detector characteristics Detection of X-Rays Solid state detectors Proportional counters Microcalorimeters Detector characteristics Solid State X-ray Detectors X-ray interacts in material to produce photoelectrons which are collected

More information

An IDL Based Image Deconvolution Software Package

An IDL Based Image Deconvolution Software Package An IDL Based Image Deconvolution Software Package F. Városi and W. B. Landsman Hughes STX Co., Code 685, NASA/GSFC, Greenbelt, MD 20771 Abstract. Using the Interactive Data Language (IDL), we have implemented

More information

Metal Artifact Reduction and Dose Efficiency Improvement on Photon Counting Detector CT using an Additional Tin Filter

Metal Artifact Reduction and Dose Efficiency Improvement on Photon Counting Detector CT using an Additional Tin Filter Metal Artifact Reduction and Dose Efficiency Improvement on Photon Counting Detector CT using an Additional Tin Filter Wei Zhou, Dilbar Abdurakhimova, Kishore Rajendran, Cynthia McCollough, Shuai Leng

More information

X-ray imaging with amorphous selenium: Theoretical feasibility of the liquid crystal light valve for radiography

X-ray imaging with amorphous selenium: Theoretical feasibility of the liquid crystal light valve for radiography X-ray imaging with amorphous selenium: Theoretical feasibility of the liquid crystal light valve for radiography Pia-Krista Rieppo and J. A. Rowlands a) Departments of Medical Biophysics and Medical Imaging,

More information

Quality-Assurance Check of Collimator and Phantom- Scatter Factors

Quality-Assurance Check of Collimator and Phantom- Scatter Factors Quality-Assurance Check of Collimator and Phantom- Scatter Factors Ramesh C. Tailor, David S. Followill, Nadia Hernandez, Timothy S. Zhu, and Geoffrey S. Ibbott. UT MD Anderson Cancer Center, Houston TX.

More information

Astronomy 114. Lecture 26: Telescopes. Martin D. Weinberg. UMass/Astronomy Department

Astronomy 114. Lecture 26: Telescopes. Martin D. Weinberg. UMass/Astronomy Department Astronomy 114 Lecture 26: Telescopes Martin D. Weinberg weinberg@astro.umass.edu UMass/Astronomy Department A114: Lecture 26 17 Apr 2007 Read: Ch. 6,26 Astronomy 114 1/17 Announcements Quiz #2: we re aiming

More information

Objective Functions for Tomographic Reconstruction from. Randoms-Precorrected PET Scans. gram separately, this process doubles the storage space for

Objective Functions for Tomographic Reconstruction from. Randoms-Precorrected PET Scans. gram separately, this process doubles the storage space for Objective Functions for Tomographic Reconstruction from Randoms-Precorrected PET Scans Mehmet Yavuz and Jerey A. Fessler Dept. of EECS, University of Michigan Abstract In PET, usually the data are precorrected

More information

Student Projects for

Student Projects for MINERALS RESOURCES Student Projects for 2016-17 The CSIRO On-line Analysis (OLA) Group offers opportunities for students to undertake applied physics research projects at our Lucas Heights laboratories.

More information

The HERMES Dual-Radiator Ring Imaging Cerenkov Detector N.Akopov et al., Nucl. Instrum. Meth. A479 (2002) 511

The HERMES Dual-Radiator Ring Imaging Cerenkov Detector N.Akopov et al., Nucl. Instrum. Meth. A479 (2002) 511 The HERMES Dual-Radiator Ring Imaging Cerenkov Detector N.Akopov et al., Nucl. Instrum. Meth. A479 (2002) 511 Shibata Lab 11R50047 Jennifer Newsham YSEP student from Georgia Institute of Technology, Atlanta,

More information

Uniform Quadratic Penalties Cause Nonuniform Spatial Resolution

Uniform Quadratic Penalties Cause Nonuniform Spatial Resolution Uniform Quadratic Penalties Cause Nonuniform Spatial Resolution Jeffrey A. Fessler and W. Leslie Rogers 3480 Kresge 111, Box 0552, University of Michigan, Ann Arbor, MI 48109-0552 ABSTRACT This paper examines

More information

SPATIAL RESOLUTION PROPERTIES OF PENALIZED WEIGHTED LEAST-SQUARES TOMOGRAPHIC IMAGE RECONSTRUCTION WITH MODEL MISMATCH

SPATIAL RESOLUTION PROPERTIES OF PENALIZED WEIGHTED LEAST-SQUARES TOMOGRAPHIC IMAGE RECONSTRUCTION WITH MODEL MISMATCH SPATIAL RESOLUTION PROPERTIES OF PENALIZED WEIGHTED LEAST-SQUARES TOMOGRAPHIC IMAGE RECONSTRUCTION WITH MODEL MISMATCH Jeffrey A. Fessler COMMUNICATIONS & SIGNAL PROCESSING LABORATORY Department of Electrical

More information

Monte Carlo Analyses of X-Ray Absorption, Noise, and Detective Quantum Efficiency Considering Therapeutic X-Ray Spectrum in Portal Imaging Detector

Monte Carlo Analyses of X-Ray Absorption, Noise, and Detective Quantum Efficiency Considering Therapeutic X-Ray Spectrum in Portal Imaging Detector IEEE TRANSACTIONS ON NUCLEAR SCIENCE, VOL. 48, NO. 4, AUGUST 2001 1423 Monte Carlo Analyses of X-Ray Absorption, Noise, and Detective Quantum Efficiency Considering Therapeutic X-Ray Spectrum in Portal

More information

Field Tests of elongated Sodium LGS wave-front sensing for the E-ELT

Field Tests of elongated Sodium LGS wave-front sensing for the E-ELT Florence, Italy. May 2013 ISBN: 978-88-908876-0-4 DOI: 10.12839/AO4ELT3.13437 Field Tests of elongated Sodium LGS wave-front sensing for the E-ELT Gérard Rousset 1a, Damien Gratadour 1, TIm J. Morris 2,

More information

Status Report: Multi-Channel TCT

Status Report: Multi-Channel TCT Status Report: Multi-Channel TCT J. Becker, D. Eckstein, R. Klanner, G. Steinbrück University of Hamburg 1. Introduction 2. Set-up and measurement techniques 3. First results from single-channel measurements

More information

Hanle Echelle Spectrograph (HESP)

Hanle Echelle Spectrograph (HESP) Hanle Echelle Spectrograph (HESP) Bench mounted High resolution echelle spectrograph fed by Optical Fiber Second generation instrument for HCT The project is a technical collaboration between Indian Institute

More information

Polaris 3-D CdZnTe (CZT) Gamma-Ray Imaging Spectrometers

Polaris 3-D CdZnTe (CZT) Gamma-Ray Imaging Spectrometers Polaris 3-D CdZnTe (CZT) Gamma-Ray Imaging Spectrometers Zhong He ISOE-ALARA Symposium, January 12, 2015 Acknowledgements: DOD, DOE and DHS John M. Palms Outstanding Innovation Began in early 1960s Thank

More information

Simulations for H.E.S.S.

Simulations for H.E.S.S. Simulations for H.E.S.S. by K. Bernlöhr MPIK Heidelberg & HU Berlin Air shower measurement methods Imaging atmospheric Cherenkov telescopes In the imaging atmospheric Cherenkov telescope (IACT) technique,

More information

Overview and Status of the Austrian Particle Therapy Facility MedAustron. Peter Urschütz

Overview and Status of the Austrian Particle Therapy Facility MedAustron. Peter Urschütz Overview and Status of the Austrian Particle Therapy Facility MedAustron Peter Urschütz MedAustron Centre for ion beam therapy and non-clinical research Treatment of 1200 patients/year in full operation

More information

PHYS 352. Shot Noise, 1/f Noise. current (which is rate of charge)

PHYS 352. Shot Noise, 1/f Noise. current (which is rate of charge) PHYS 352 Shot Noise, 1/f Noise Shot Noise current (which is rate of charge) current does not flow completely smoothly when charges arrive as quanta e.g. charge collection in a photodiode is a random, independent

More information

Status Report: Charge Cloud Explosion

Status Report: Charge Cloud Explosion Status Report: Charge Cloud Explosion J. Becker, D. Eckstein, R. Klanner, G. Steinbrück University of Hamburg Detector laboratory 1. Introduction and Motivation. Set-up available for measurement 3. Measurements

More information

An Accurate and Efficient Gaussian Fit Centroiding Algorithm for. Star Trackers

An Accurate and Efficient Gaussian Fit Centroiding Algorithm for. Star Trackers An Accurate and Efficient Gaussian Fit Centroiding Algorithm for Star Trackers Tjorven Delabie, Joris De Schutter, Bart Vandenbussche ABSTRACT This paper presents a novel centroiding algorithm for star

More information

Midterm Review. Yao Wang Polytechnic University, Brooklyn, NY 11201

Midterm Review. Yao Wang Polytechnic University, Brooklyn, NY 11201 Midterm Review Yao Wang Polytechnic University, Brooklyn, NY 11201 Based on J. L. Prince and J. M. Links, Medical maging Signals and Systems, and lecture notes by Prince. Figures are from the textbook.

More information

Image Deconvolution. Xiang Hao. Scientific Computing and Imaging Institute, University of Utah, UT,

Image Deconvolution. Xiang Hao. Scientific Computing and Imaging Institute, University of Utah, UT, Image Deconvolution Xiang Hao Scientific Computing and Imaging Institute, University of Utah, UT, hao@cs.utah.edu Abstract. This is a assignment report of Mathematics of Imaging course. The topic is image

More information

Measurement And Uncertainty

Measurement And Uncertainty Measurement And Uncertainty Based on Guidelines for Evaluating and Expressing the Uncertainty of NIST Measurement Results, NIST Technical Note 1297, 1994 Edition PHYS 407 1 Measurement approximates or

More information

Lecture 5: Tomographic nuclear systems: SPECT

Lecture 5: Tomographic nuclear systems: SPECT Lecture 5: Tomographic nuclear systems: SPECT Field trip this saturday at 11 AM at UWMC meet in main hospital lobby at 11 AM if you miss the 'boat', page me at 540-4950 should take ~1 to 1.5 hours, depending

More information

Detector. * All clinical images are courtesy of. University, Jerusalem. Ami Altman, Ph.D., and Raz Carmi Ph.D., CT BU, PHILIPS Healthcare

Detector. * All clinical images are courtesy of. University, Jerusalem. Ami Altman, Ph.D., and Raz Carmi Ph.D., CT BU, PHILIPS Healthcare AD Dual-Energy alenerg CT Based on A Double Layer Detector * All clinical images are courtesy of Hadassah Medical Center, The Hebrew University, Jerusalem Ami Altman, Ph.D., and Raz Carmi Ph.D., CT BU,

More information

Analytical Approach to Regularization Design for Isotropic Spatial Resolution

Analytical Approach to Regularization Design for Isotropic Spatial Resolution Analytical Approach to Regularization Design for Isotropic Spatial Resolution Jeffrey A Fessler, Senior Member, IEEE Abstract In emission tomography, conventional quadratic regularization methods lead

More information

MAP Reconstruction From Spatially Correlated PET Data

MAP Reconstruction From Spatially Correlated PET Data IEEE TRANSACTIONS ON NUCLEAR SCIENCE, VOL 50, NO 5, OCTOBER 2003 1445 MAP Reconstruction From Spatially Correlated PET Data Adam Alessio, Student Member, IEEE, Ken Sauer, Member, IEEE, and Charles A Bouman,

More information

MAX, a Laue Diffraction Lens for nuclear astrophysics

MAX, a Laue Diffraction Lens for nuclear astrophysics b MAX, a Laue Diffraction Lens for nuclear astrophysics Nicolas BARRIERE CESR, Toulouse France 1 Outlines Concept Scientific objectives Lens features and energy bandpasses Performances 2nd generation crystal

More information

Electron density and effective atomic number images generated by dual energy imaging with a 320-detector CT system: A feasibility study

Electron density and effective atomic number images generated by dual energy imaging with a 320-detector CT system: A feasibility study Electron density and effective atomic number images generated by dual energy imaging with a 320-detector CT system: A feasibility study Poster No.: C-0403 Congress: ECR 2014 Type: Scientific Exhibit Authors:

More information

Data Acquisition and Image Formation Methods for Multi Energy CT

Data Acquisition and Image Formation Methods for Multi Energy CT Data Acquisition and Image Formation Methods for Multi Energy CT Cynthia H. McCollough, PhD, DABR, FAIMBE, FAAPM, FACR Professor of Medical Physics and Biomedical Engineering Director, CT Clinical Innovation

More information

The effect of dose calculation uncertainty on the evaluation of radiotherapy plans

The effect of dose calculation uncertainty on the evaluation of radiotherapy plans The effect of dose calculation uncertainty on the evaluation of radiotherapy plans P. J. Keall a) and J. V. Siebers Department of Radiation Oncology, Medical College of Virginia Hospitals, Virginia Commonwealth

More information

1. Which of the following statements is true about Bremsstrahlung and Characteristic Radiation?

1. Which of the following statements is true about Bremsstrahlung and Characteristic Radiation? BioE 1330 - Review Chapters 4, 5, and 6 (X-ray and CT) 9/27/2018 Instructions: On the Answer Sheet, enter your 2-digit ID number (with a leading 0 if needed) in the boxes of the ID section. Fill in the

More information

Take-Home Final Exam Last Possible Due Date: Dec. 21, 2004, 5 p.m.

Take-Home Final Exam Last Possible Due Date: Dec. 21, 2004, 5 p.m. Take-Home Final Exam Last Possible Due Date: Dec 1, 004, 5 pm Your solutions to the exam should be handed in to the instructor (BIRB 1088) or to Eve Gochis, the MRI lab administrator (BIRB 107) no later

More information

Bayesian Estimator for Angle Recovery: Event Classification and Reconstruction in Positron Emission Tomography

Bayesian Estimator for Angle Recovery: Event Classification and Reconstruction in Positron Emission Tomography Bayesian Estimator for Angle Recovery: Event Classification and Reconstruction in Positron Emission Tomography Angela M K Foudray*'''' and Craig S Levin* 'Stanford University Molecular Imaging Program

More information

Fast variance predictions for 3D cone-beam CT with quadratic regularization

Fast variance predictions for 3D cone-beam CT with quadratic regularization Fast variance predictions for 3D cone-beam CT with quadratic regularization Yingying Zhang-O Connor and Jeffrey A. Fessler a a Department of Electrical Engineering and Computer Science, The University

More information

Prospects for achieving < 100 ps FWHM coincidence resolving time in time-of-flight PET

Prospects for achieving < 100 ps FWHM coincidence resolving time in time-of-flight PET Prospects for achieving < 100 ps FWHM coincidence resolving time in time-of-flight PET, 28-Feb-2012, ICTR-PHE, Geneva, Switzerland 1 Time-of-flight PET Colon cancer, left upper quadrant peritoneal node

More information

Prompt gamma measurements for the verification of dose deposition in proton therapy. Contents. Two Proton Beam Facilities for Therapy and Research

Prompt gamma measurements for the verification of dose deposition in proton therapy. Contents. Two Proton Beam Facilities for Therapy and Research Prompt gamma measurements for the verification of dose deposition in proton therapy Two Proton Beam Facilities for Therapy and Research Ion Beam Facilities in Korea 1. Proton therapy facility at National

More information

Multi-Energy CT: Principles, Processing

Multi-Energy CT: Principles, Processing Multi-Energy CT: Principles, Processing and Clinical Applications Shuai Leng, PhD Associate Professor Department of Radiology Mayo Clinic, Rochester, MN Clinical Motivation CT number depends on x-ray attenuation

More information

X-ray Data Collection. Bio5325 Spring 2006

X-ray Data Collection. Bio5325 Spring 2006 X-ray Data Collection Bio535 Spring 006 Obtaining I hkl and α (Ihkl) from Frame Images Braggs Law -predicts conditions for in-phase scattering by equivalent atoms lying in planes that transect a crystal.

More information

THE spectroscopic performance of large volume CdZnTe

THE spectroscopic performance of large volume CdZnTe 3098 IEEE TRANSACTIONS ON NUCLEAR SCIENCE, VOL. 51, NO. 6, DECEMBER 2004 Analysis of Detector Response Using 3-D Position-Sensitive CZT Gamma-Ray Spectrometers Feng Zhang, Student Member, IEEE, Zhong He,

More information

Fundamental limits to the precision in astrometry and photometry using array detectors through the Cramér-Rao minimum variance bound

Fundamental limits to the precision in astrometry and photometry using array detectors through the Cramér-Rao minimum variance bound Fundamental limits to the precision in astrometry and photometry using array detectors through the Cramér-Rao minimum variance bound Jorge Silva, Marcos Orchard DIE Rene Mendez DAS U. de Chile Espinosa

More information

Histogram Processing

Histogram Processing Histogram Processing The histogram of a digital image with gray levels in the range [0,L-] is a discrete function h ( r k ) = n k where r k n k = k th gray level = number of pixels in the image having

More information

Point spread function reconstruction at W.M. Keck Observatory : progress and beyond

Point spread function reconstruction at W.M. Keck Observatory : progress and beyond Point spread function reconstruction at W.M. Keck Observatory : progress and beyond Olivier Beltramo-Martin Aix-Marseille Univ., LAM, A*MIDEX, Extra November 9th, 217 - LAM Olivier Beltramo-Martin (LAM)

More information

5 Error Propagation We start from eq , which shows the explicit dependence of g on the measured variables t and h. Thus.

5 Error Propagation We start from eq , which shows the explicit dependence of g on the measured variables t and h. Thus. 5 Error Propagation We start from eq..4., which shows the explicit dependence of g on the measured variables t and h. Thus g(t,h) = h/t eq..5. The simplest way to get the error in g from the error in t

More information

Henry Ford NERS/BIOE 481. Lecture 07 Metrics of Image Quality

Henry Ford NERS/BIOE 481. Lecture 07 Metrics of Image Quality NERS/BIOE 481 Lecture 07 Metrics of Image Quality Michael Flynn, Adjunct Prof Nuclear Engr & Rad. Science mikef@umich.edu mikef@rad.hfh.edu Henry Ford Health System RADIOLOGY RESEARCH I.A.1 - General Model

More information

Magnetic removal of electron contamination in radiotherapy x-ray beams

Magnetic removal of electron contamination in radiotherapy x-ray beams University of Wollongong Research Online University of Wollongong Thesis Collection 1954-2016 University of Wollongong Thesis Collections 2006 Magnetic removal of electron contamination in radiotherapy

More information

Modular Survey Spectrometer and Compton Imager

Modular Survey Spectrometer and Compton Imager 1 Modular Survey Spectrometer and Compton Imager Audrey MacLeod Ionizing Radiation Standards Measurement Science and Standards National Research Council Canada On behalf of the SCoTSS collaboration (Silicon

More information

Inverse problem and optimization

Inverse problem and optimization Inverse problem and optimization Laurent Condat, Nelly Pustelnik CNRS, Gipsa-lab CNRS, Laboratoire de Physique de l ENS de Lyon Decembre, 15th 2016 Inverse problem and optimization 2/36 Plan 1. Examples

More information

EIC Simulations. Thomas Kitching, EIC Weak Lensing & Simulation Working Groups

EIC Simulations. Thomas Kitching, EIC Weak Lensing & Simulation Working Groups EIC Simulations Thomas Kitching A. Amara, S. Bridle, O. Boulade, B. Dobke, A. Fontana, A. Grazian, A. Heavens, A. Kiessling, M. Meneghetti, S. Paulin-Henriksson, J. Rhodes, A. Refregier, A. Taylor, R.

More information

A quantative comparison of two restoration methods as applied to confocal microscopy

A quantative comparison of two restoration methods as applied to confocal microscopy A quantative comparison of two restoration methods as applied to confocal microscopy Geert M.P. van Kempen 1, Hans T.M. van der Voort, Lucas J. van Vliet 1 1 Pattern Recognition Group, Delft University

More information

F3-A2/F3-A3: Tensor-based formulation for Spectral Computed Tomography (CT) with novel regularization techniques

F3-A2/F3-A3: Tensor-based formulation for Spectral Computed Tomography (CT) with novel regularization techniques F3-A2/F3-A3: Tensor-based formulation for Spectral Computed Tomography (CT) with novel regularization techniques Abstract Spectral computed tomography (CT) has become possible with the development of photon

More information

Direct measurement of spectral phase for ultrashort laser pulses

Direct measurement of spectral phase for ultrashort laser pulses Direct measurement of spectral phase for ultrashort laser pulses Vadim V. Lozovoy, 1 Bingwei Xu, 1 Yves Coello, 1 and Marcos Dantus 1,2,* 1 Department of Chemistry, Michigan State University 2 Department

More information

8/3/2016. Chia-Ho, Hua St. Jude Children's Research Hospital. Kevin Teo The Hospital of the University of Pennsylvania

8/3/2016. Chia-Ho, Hua St. Jude Children's Research Hospital. Kevin Teo The Hospital of the University of Pennsylvania Bijan Arjomandy, Ph.D. Mclaren Proton Therapy Center Mark Pankuch, Ph.D. Cadence Health Proton Center Chia-Ho, Hua St. Jude Children's Research Hospital Kevin Teo The Hospital of the University of Pennsylvania

More information

Fast variance predictions for 3D cone-beam CT with quadratic regularization

Fast variance predictions for 3D cone-beam CT with quadratic regularization Honorable Mention Poster Award Fast variance predictions for 3D cone-beam CT with quadratic regularization Yingying Zhang-O Connor and Jeffrey A. Fessler a a Department of Electrical Engineering and Computer

More information

Pressure effect in the X-ray intrinsic position resolution in noble gases and mixtures

Pressure effect in the X-ray intrinsic position resolution in noble gases and mixtures Prepared for submission to JINST Pressure effect in the X-ray intrinsic position resolution in noble gases and mixtures arxiv:1605.06256v3 [physics.ins-det] 24 May 2016 C.D.R. Azevedo, a,1 P.M. Correia,

More information

Quantum imaging of faint objects

Quantum imaging of faint objects Italian Quantum Information Science Conference 008, Camerino Quantum imaging of faint objects Theory : Lucia Caspani, Enrico Brambilla, Luigi Lugiato, Alessandra Gatti Experiment: Ottavia Jederkiewicz,

More information